E5CN-RMT-W-500 AC100-240

器件型号:E5CN-RMT-W-500 AC100-240
器件类别:测试和测量    控制器 - 处理    温度   
文件大小:20106.46KB,共17页
厂商名称:OMRON
厂商官网:https://www.omron.com
标准:  
下载文档

器件描述

temp controller dgtl 1/16 din

参数

Datasheets:
E5CN/E5CN-U Datasheet:
E5xN User Manual:
PCN Design/Specification:
Multiple devices Modification July/2013:
Standard Package : 1
Category: Industrial Controls, Meters
Family: Controllers - Process, Temperature
Series: E5CN
Type: Temperature Controller (RTD, Type B, E, J, K, L, N, PLII, R, S, T, U, W)
Input Range: -200°C ~ 2300°C, 0 ~ 50mV
Output Type: Relay
Control Method: On/Off, Proportional (PID)
Communications: Option Cards Available
Number Of Characters Per Row: 4, 4
Display Type: LED - Dual Color Characters
Display Characters - Height: 0.433" (11.00mm), 0.256" (6.50mm)
Voltage - Supply: 100 ~ 240VAC
Panel Cutout Dimensions: Square - 45.00mm x 45.00mm
Mounting Type: Panel Mount
Termination Style: Screw Terminal
Ingress Protection: IP66 (Face), IP20 (Case), IP00 (Terminal)
Operating Temperature: -10°C ~ 55°C
Features: Option Cards Available
Weight: 0.331 lb (150.14g)
Other Names: E5CN/RMT/W/500 AC100/240E5CNRMTW500AC100240

E5CN-RMT-W-500 AC100-240器件文档内容

Basic-type Digital Temperature Controller

E5CN/E5CN-U (48 x 48 mm)

                                                                                                 CSM_E5CN_E5CN-U_DS_E_5_7

New 48 x 48-mm Basic Temperature                                                     48 48-mm    48 48-mm
Controller with Enhanced Functions and                                                   E5CN        E5CN-U
Performance. Improved Indication Accuracy
and Preventive Maintenance Function.                                     For the most recent information on models that have been certified for
                                                                         safety standards, refer to your OMRON website.
Indication Accuracy
  Thermocouple input: 0.3% of PV (previous models: 0.5%)                                Refer to Safety Precautions for E5@N/E5@N-H.
  Pt input: 0.2% of PV (previous models: 0.5%)
  Analog input: 0.2% FS (previous models: 0.5%)                                    Refer to Operation for E5@N/E5@N-H for operating
                                                                                     procedures.
New E5CN-U Models (Plug-in Models) with analog inputs and
  current outputs.

A PV/SV-status display function can be set to automatically alternate
  between displaying the status of the Temperature Controller (auto/
  manual, RUN/STOP, and alarms) and the PV or SV.

Preventive maintenance for relays in the Temperature
  Controller using a Control Output ON/OFF Counter.

Main I/O Functions

                                   Event Inputs  E5CN
                                    None
                                    Two               2-level Display: PV and SV 4-digit Display

Sensor Inputs                                    Control Output 2        Auxiliary Outputs   Auto/manual switching
Universal thermocouple/Pt inputs                None                   None             Temperature Controller status display
                                                 Voltage output         One               Simple program function
(Models with temperature inputs)                                        Two               Control output ON/OFF count alarm
Analog current/voltage inputs                   (for driving SSR)                         PV change rate alarm
                                                                                             Models also available with RS-485
(Models with analog inputs)
                                                                                             communications
Indication Accuracy
Thermocouple input: 0.3% of PV                Control Output 1
Pt input: 0.2% of PV                           Relay output
Analog input: 0.2% FS                         Voltage output (for driving SSR)
                                                 Current output
Sampling Period                                  Long-life relay output (hybrid)
250 ms

This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
and other information required for operation before attempting to use the product.
E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156)
E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158)

                                                                                 1
                                                                                                     E5CN/E5CN-U

Lineup

                                                                                  1 control output   0 or 2 auxiliary outputs

                                                               Temperature input  2 control outputs 2 auxiliary outputs

            Terminal block                                        Analog input    1 control output   0 or 2 auxiliary outputs
                Plug-in                                        Temperature input
E5CN                                                                              2 control outputs  2 auxiliary outputs
                                                                  Analog input    1 control output
Basic Type                                                                        1 control output   0, 1, or 2 auxiliary
                                                                                                     outputs

                                                                                                     0, 1, or 2 auxiliary
                                                                                                     outputs

Note: Models with one control output and one or two auxiliary outputs and models with two control outputs can be used for heating/cooling control.

Model Number Structure                                         Option Units

Model Number Legend                                            E53-CN@@@

Controllers                                                                1 234

E5CN-@@M@@-@-500                                               1. Applicable Controller
                                                                   CN: E5CN or E5CN-H
               12345 6 7
1. Control Output 1                                            2. Function 1
                                                                   Blank: None
    R: Relay output                                                Q: Control output 2 (voltage for driving SSR)
    Q: Voltage output (for driving SSR)                            P: Power supply for sensor
    C: Current output
    Y: Long-life relay output (hybrid) *1                      3. Function 2
                                                                   Blank: None
2. Auxiliary Outputs *2                                            H: Heater burnout/SSR failure/Heater overcurrent detection (CT1)
    Blank: None                                                    HH: Heater burnout/SSR failure/Heater overcurrent detection
    2: Two outputs                                                       (CT2)
                                                                   B: Two event inputs
3. Option                                                          03: RS-485 communications
    M: Option Unit can be mounted.                                 H03: Heater burnout/SSR failure/Heater overcurrent detection
                                                                          (CT1) + RS-485 communications
4. Input Type                                                      HB: Heater burnout/SSR failure/Heater overcurrent detection
    T: Universal thermocouple/platinum resistance thermometer            (CT1) + Two event inputs
    L: Analog current/voltage input                                HH03: Heater burnout/SSR failure/Heater overcurrent detection
                                                                            (CT2) + RS-485 communications
5. Power Supply Voltage
    Blank: 100 to 240 VAC                                      4. Version
    D: 24 VAC/VDC                                                  N2: Applicable only to models released after January 2008

6. Case Color
    Blank: Black
    W: Silver

7. Terminal Cover
    -500: With terminal cover

Note: 1. Not all combinations of function 1 and function 2 specifications are possible for Option Units (E53-@@@@).
        2. Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for details.

*1. Always connect an AC load to a long-life relay output. The output will not turn OFF if a DC load is connected because a triac is used for
     switching the circuit. For details, check the conditions in Ratings.

*2. Auxiliary outputs are contact outputs that can be used to output alarms or results of logic operations.

                                                                                                                                                            2
                                                                                                                     E5CN/E5CN-U

Ordering Information

Controllers with Terminal Blocks

Size            Case color  Power supply           Input type   Auxiliary outputs              Control output 1                  Model
                                voltage                        None
                                                               2                   Relay output                      E5CN-RMT-500
                            100 to 240 VAC  Thermocouple or                        Voltage output (for driving SSR)  E5CN-QMT-500
                                            Resistance                             Current output                    E5CN-CMT-500
                                            thermometer                            Relay output                      E5CN-R2MT-500
                                                                                   Voltage output (for driving SSR)  E5CN-Q2MT-500
                            24 VAC/VDC      Thermocouple or    None                Current output                    E5CN-C2MT-500
                                            Resistance         2                   Long-life relay output (hybrid)   E5CN-Y2MT-500
                                            thermometer                            Relay output                      E5CN-RMTD-500
                                                                                   Voltage output (for driving SSR)  E5CN-QMTD-500
              Black                                                                Current output                    E5CN-CMTD-500
                                                                                   Relay output                      E5CN-R2MTD-500
1/16 DIN                    100 to 240 VAC  Analog             None                Voltage output (for driving SSR)  E5CN-Q2MTD-500
48 48 78                                (current/voltage)  2                   Current output                    E5CN-C2MTD-500
(W H D)                                                                        Relay output                      E5CN-RML-500
                                                                                   Voltage output (for driving SSR)  E5CN-QML-500
                            24 VAC/VDC      Analog             2                   Current output                    E5CN-CML-500
                                            (current/voltage)                      Relay output                      E5CN-R2ML-500
                                                                                   Voltage output (for driving SSR)  E5CN-Q2ML-500
                            100 to 240 VAC                     None                Current output                    E5CN-C2ML-500
                                                               2                   Long-life relay output (hybrid)   E5CN-Y2ML-500
              Silver                        Thermocouple or                        Relay output                      E5CN-R2MLD-500
                                            Resistance                             Voltage output (for driving SSR)  E5CN-Q2MLD-500
                                            thermometer                            Current output                    E5CN-C2MLD-500
                                                                                   Relay output                      E5CN-RMT-W-500
                            24 VAC/VDC                         2                   Voltage output (for driving SSR)  E5CN-QMT-W-500
                                                                                   Current output                    E5CN-CMT-W-500
                                                                                   Relay output                      E5CN-R2MT-W-500
                                                                                   Voltage output (for driving SSR)  E5CN-Q2MT-W-500
                                                                                   Current output                    E5CN-C2MT-W-500
                                                                                   Long-life relay output (hybrid)   E5CN-Y2MT-W-500
                                                                                   Relay output                      E5CN-R2MTD-W-500
                                                                                   Voltage output (for driving SSR)  E5CN-Q2MTD-W-500
                                                                                   Current output                    E5CN-C2MTD-W-500

Note: Models with analog inputs do not have temperature unit indicators.

Option Units

One of the following Option Units can be mounted to provide the E5CN with additional functions.

                                                     Functions                                                                  Model
                                                                                                                            (See Note 2.)

Communications  3-phase heater burnout/SSR failure/                                                                         E53-CNHH03N2
RS-485          Heater overcurrent detection

                Heater burnout/SSR failure/Heater    Event inputs                                                           E53-CNHBN2
                overcurrent detection

Communications                                                       Control output 2                                       E53-CNQ03N2
RS-485                                                               (Voltage for driving SSR)

                                                     Event inputs                                External power supply for  E53-CNPBN2
                                                                                                 ES1B

                Heater burnout/SSR failure/Heater                                                External power supply for  E53-CNPHN2
                overcurrent detection                                                            ES1B

Communications                                                                                   External power supply for  E53-CNP03N2
RS-485                                                                                           ES1B

Communications  Heater burnout/SSR failure/Heater                                                                           E53-CNH03N2
RS-485          overcurrent detection

Communications                                                                                                              E53-CN03N2
RS-485

                                                     Event inputs                                                           E53-CNBN2

                Heater burnout/SSR failure/Heater                    Control output 2                                       E53-CNQHN2
                overcurrent detection                                (Voltage for driving SSR)

                3-phase heater burnout/SSR failure/                  Control output 2                                       E53-CNQHHN2
                Heater overcurrent detection                         (Voltage for driving SSR)

                                                     Event inputs    Control output 2                                       E53-CNQBN2
                                                                     (Voltage for driving SSR)

Note: 1. Option Units cannot be used for plug-in models.

            These Option Units are applicable only to models released after January 2008.
        2. If models with heater burnout detection are used together with the E5CN-C@ Temperature Controller and control output 1 (current output)

            is assigned to the heating control output, heater burnout detection will be disabled.

                                                                                                                                                    3
                                                                                                 E5CN/E5CN-U

Model Number Structure

Model Number Legend (Plug-in-type Controllers)

E5CN-@@@U                                                                 3. Input Type
                                                                              T: Universal thermocouple/platinum resistance thermometer
               1234                                                           L: Analog Input

1. Output Type                                                            4. Plug-in type
    R: Relay output                                                           U: Plug-in type
    Q: Voltage output (for driving SSR)
    C: Current output

2. Number of Alarms
    Blank: No alarm
    1: One alarm
    2: Two alarms

Ordering Information

Plug-in-type Controllers

Size  Case color  Power supply           Input type         Auxiliary outputs  Control output 1  Model
                      voltage

                                                                               Relay output      E5CN-RTU

                                                            None               Voltage output (for driving SSR) E5CN-QTU

                                                                               Current output    E5CN-CTU

                                         Thermocouple or                       Relay output      E5CN-R1TU

                                         resistance         1                  Voltage output (for driving SSR) E5CN-Q1TU

                                         thermometer                           Current output    E5CN-C1TU

                                                                               Relay output      E5CN-R2TU

                  100 to 240 VAC                            2                  Voltage output (for driving SSR) E5CN-Q2TU

                                                                               Current output    E5CN-C2TU

                                                                               Relay output      E5CN-R1LU

                                                            1                  Voltage output (for driving SSR) E5CN-Q1LU

1/16 DIN Black                           Analog                                Current output    E5CN-C1LU
                                         (current/voltage)                     Relay output      E5CN-R2LU

                                                            2                  Voltage output (for driving SSR) E5CN-Q2LU

                                                                               Current output    E5CN-C2LU

                                                                               Relay output      E5CN-RTDU

                                                            None               Voltage output (for driving SSR) E5CN-QTDU

                                                                               Current output    E5CN-CTDU

                                         Thermocouple or                       Relay output      E5CN-R1TDU

                  24 VAC/VDC             resistance         1                  Voltage output (for driving SSR) E5CN-Q1TDU

                                         thermometer                           Current output    E5CN-C1TDU

                                                                               Relay output      E5CN-R2TDU

                                                            2                  Voltage output (for driving SSR) E5CN-Q2TDU

                                                                               Current output    E5CN-C2TDU

Note: Models with analog inputs do not have temperature unit indicators.

                                                                                                                                         4
                                                                                                                        E5CN/E5CN-U

Accessories (Order Separately)                                         Adapter

USB-Serial Conversion Cable                                            Connectable models                               Model

                                         Model                         Terminal block models                            Y92F-45
                                      E58-CIFQ1

Terminal Cover                                                         Note: Use this Adapter when the panel has been previously prepared
                                                                               for the E5B@.

Connectable models          Model                                      DIN Track Mounting Adapter

Terminal block models       E53-COV17                                                                           Model
                                                                                                               Y92F-52
Note: The Terminal Cover comes with the E5CN-@@@-500 models.

Waterproof Packing                                                     Sockets (for Plug-in Models)                        Model
                                                                                                                        P2CF-11
                                         Model                                                      Type                P2CF-11-E
                                        Y92S-29                         Front-connecting Socket                         P3GA-11
Note: The Waterproof Packing is included with the Controller only for   Front-connecting Socket with Finger Protection
        models with terminal blocks.                                    Back-connecting Socket                          Y92A-48G
                                                                        Terminal Cover for Back-connecting socket with
Current Transformers (CTs)   Model                                      Finger Protection
                            E54-CT1
           Hole diameter    E54-CT3                                    Front cover
                5.8 dia.
               12.0 dia.                                                Hard Front Cover
                                                                        Soft Front Cover
                                                                                          Type                             Model
                                                                                                                        Y92A-48B
                                                                                                                        Y92A-48D

                                                                       CX-Thermo Support Software

                                                                                                                Model
                                                                                                           EST2-2C-MV4

                                                                                                                                           5
                                                                                                             E5CN/E5CN-U

Specifications

Ratings

Power supply voltage         No D in model number: 100 to 240 VAC, 50/60 Hz
                             D in model number: 24 VAC, 50/60 Hz; 24 VDC

Operating voltage range      85% to 110% of rated supply voltage

Power      E5CN              100 to 240 VAC: 7.5 VA (max.) (E5CN-R2T at 100 VAC: 3.0 VA)
consump-   E5CN-U            24 VAC/VDC: 5 VA/3 W (max.) (E5CN-R2TD at 24 VAC: 2.7 VA)
tion
                             100 to 240 VAC: 6 VA (max.)
                             24 VAC/VDC: 3 VA/2 W (max.) (models with current output: 4 VA/2 W)

Sensor input                 Models with temperature inputs
                               Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
                               Platinum resistance thermometer: Pt100 or JPt100
                               Infrared temperature sensor (ES1B): 10 to 70C, 60 to 120C, 115 to 165C, or 140 to 260C
                               Voltage input: 0 to 50 mV

                             Models with analog inputs
                               Current input: 4 to 20 mA or 0 to 20 mA
                               Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

Input impedance              Current input: 150  max., Voltage input: 1 M min. (Use a 1:1 connection when connecting the ES2-HB.)

Control method               ON/OFF control or 2-PID control (with auto-tuning)

           Relay output      E5CN    SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable
                             E5CN-U  load: 5 V, 10 mA

                                     SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load:
                                     5 V, 10 mA

Control    Voltage output    E5CN Output voltage: 12 VDC 15% (PNP), max. load current: 21 mA, with short-circuit protection
outputs
           (for driving SSR) E5CN-U circuit

           Current output    E5CN 4 to 20 mA DC/0 to 20 mA DC, load: 600  max., resolution: approx. 10,000

           Long-life relay   E5CN    SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 1,000,000 operations, load power supply
           output                    voltage: 75 to 250 VAC (DC loads cannot be connected.), minimum applicable load: 5 V, 10 mA,
                                     leakage current: 5 mA max. (250 VAC, 60 Hz)

Auxiliary  Number of outputs 1 or 2 max. (Depends on the model.)
outputs
           Output            Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum
           specifications    applicable load: 5 V, 10 mA

           Number of inputs 2

Event      External contact  Contact input: ON: 1 k max., OFF: 100 k min.
inputs     input             Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
           specifications    Current flow: Approx. 7 mA per contact

External power supply for ES1B 12 VDC 10%, 20 mA, short-circuit protection circuit provided

Setting method               Digital setting using front panel keys

Indication method            11-segment digital display and individual indicators (7-segment display also possible)
                             Character height: PV: 11 mm, SV: 6.5 mm

Multi SP                     Up to four set points (SP0 to SP3) can be saved and selected using event inputs, key operations, or serial
                             communications.

Bank switching               Not supported

Other functions              Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout
                             detection (including SSR failure and heater overcurrent detection), 40% AT, 100% AT, MV limiter, input
                             digital filter, self-tuning, temperature input shift, run/stop, protection functions, control output ON/OFF
                             counter, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple
                             program, automatic cooling coefficient adjustment

Ambient operating temperature -10 to 55C (with no condensation or icing), for 3-year warranty: -10 to 50C

Ambient operating humidity   25% to 85%

Storage temperature          -25 to 65C (with no condensation or icing)

                                                                                                                                          6
                                                                                                                                                                                        E5CN/E5CN-U

Input Ranges

Thermocouple/Platinum Resistance Thermometer (Universal Inputs)

Input                           Platinum resistance                                                      Thermocouple                                                            Infrared temperature    Analog
Type                                 thermometer                                                                                                                                          sensor           input
                                                                                                                                                                                                            0 to
Name                                   Pt100         JPt100               K             J        T       EL           U             N   R  S  B    W                       PL    10 to  60 to  115  140   50 mV
                                                                                                                                                                            II   70C   120     to   to
                                                                                                                                                                                         C    165  260  Usable
                                                                                                                                                                                               C   C   in the
                                                                                                                                                                                                         following
                        2300                                                                                                                                         2300                                ranges
                        1800                                                                                                                               1800                                          by
                        1700                                                                                                            1700 1700                                                        scaling:
                        1600                                                                                                                                                                             -1999 to
                        1500                                        1300                                                         1300                                      1300                          9999 or
                        1400                                                                                                                                                                             -199.9
Temperature range (C)  1300                                                                                                                                                                             to 999.9
                        1200
                                                                                                                                                                                                             23
                        1100

                        1000                                                       850                          850
                                  850

                         900

                        800

                        700                                                                              600

                        600            500.0         500.0                500.0

                        500                                                             400.0 400 400.0               400 400.0

                        400                                                                                                                                                                         260

                        300                                                                                                                                                             120 165

                        200                   100.0          100.0                                                                                                               90

                        100                                                                                                                   100

                        0                     0.0            0.0                                                                        0  0       0                       0     0      0      0    0

                        -100.0                                            -20.0 -100 -20.0                      -100

                        -200.0 -200 -199.9           -199.9         -200                      -200 -199.9 -200        -200 -199.9 -200

Setting                         0      1      2      3          4   5        6     7       8  9 10 11 12 13 14 15 16 17 18 24 25 19 20 21 22
number

Shaded settings are the default settings.                                                                             JPt100: JIS C 1604-1989, JIS C 1606-1989
The applicable standards for the input types are as follows:                                                          Pt100: JIS C 1604-1997, IEC 751
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 584-1                                                                    PL II: According to Platinel II electromotive force charts from BASF (previously
L: Fe-CuNi, DIN 43710-1985
U: Cu-CuNi, DIN 43710-1985                                                                                                   Engelhard)
W: W5Re/W26Re, ASTM E988-1990

Models with Analog Inputs

                                Input Type                                Current                                  Voltage

Input specification                                          4 to 20mA 0 to 20 mA 1 to 5 V 0 to 5 V 0 to 10 V

Setting range                                                Usable in the following ranges by scaling:
                                                             -1999 to 9999, -199.9 to 999.9, -19.99 to 99.99 or -1.999 to 9.999

Setting number                                               0                  1             2                 3                4

Shaded settings are the default settings.

                                                                                                                                                                                                                    7
                                                                                                                                                 E5CN/E5CN-U

Alarm Outputs

Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit.
Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.

Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm 1 will be an OR output of the alarm selected from the
        following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent. To output only a heater burnout alarm, SSR
        failure alarm, and heater overcurrent alarm for alarm 1, set the alarm type to 0 (i.e., no alarm function).

                                                                                            Alarm output operation

Set value                  Alarm type            When alarm value When alarm value                                                               Description of function

                                                     X is positive                                                 X is negative

0             Alarm function OFF                 Output OFF                                                                            No alarm

                                                 ON                                         LH                                         Set the deviation in the set point by setting the alarm
                                                 OFF                                                                                   upper limit (H) and alarm lower limit (L).
1 *1          Upper- and lower-limit                                                                      *2

                                                                                            SP

                                                 ON                                             X              ON   X                  Set the upward deviation in the set point by setting
                                                 OFF                                        SP                                         the alarm value (X).
2             Upper-limit                                                                                      OFF
                                                                                                                                   SP

                                                 ON                                         X                  ON       X              Set the downward deviation in the set point by setting
                                                                                                               OFF  SP                 the alarm value (X).
3             Lower-limit                        OFF
                                                                     SP

4 *1          Upper- and lower-limit range       ON                                         LH            *3                           Set the deviation in the set point by setting the alarm
5 *1                                             OFF                                         SP                                        upper limit (H) and alarm lower limit (L).
6
              Upper- and lower-limit with        ON                                         LH                                         A standby sequence is added to the upper- and
              standby sequence                                                                                                         lower-limit alarm (1). *6
                                                 OFF                                                      *4
                                                                     SP                                                                A standby sequence is added to the upper-limit alarm
                                                                                                                                       (2). *6
                                                 *5

                                                 ON                                                 X          ON   X
                                                 OFF
              Upper-limit with standby sequence                                                                OFF
                                                                                                                                   SP
                                                                                            SP

                                                 ON                                         X                  ON       X              A standby sequence is added to the lower-limit alarm
                                                 OFF                                                           OFF  SP                 (3). *6
7             Lower-limit with standby sequence

                                                                                            SP

8             Absolute-value upper-limit         ON                                              X             ON      X               The alarm will turn ON if the process value is larger
                                                 OFF                                        0                  OFF          0          than the alarm value (X) regardless of the set point.

9             Absolute-value lower-limit         ON                                              X             ON      X               The alarm will turn ON if the process value is smaller
                                                 OFF                                        0                  OFF          0          than the alarm value (X) regardless of the set point.

10            Absolute-value upper-limit with    ON                                              X             ON      X               A standby sequence is added to the absolute-value
              standby sequence                   OFF                                        0                  OFF          0          upper-limit alarm (8). *6

11            Absolute-value lower-limit with    ON                                              X             ON      X               A standby sequence is added to the absolute-value
              standby sequence                   OFF                                        0                  OFF          0          lower-limit alarm (9). *6

12            LBA (alarm 1 type only)                                                                     ---                          *7

13            PV change rate alarm                                                                        ---                          *8

*1. With set values 1, 4 and 5, the upper and lower limit values can                                                *5. Set value: 5, Upper- and lower-limit with standby sequence
     be set independently for each alarm type, and are expressed as                                                      Always OFF when the upper-limit and lower-limit hysteresis

     "L" and "H."                                                                                                        overlaps.
*2. Set value: 1, Upper- and lower-limit alarm                                                                      *6. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature

      Case 1          Case 2               Case 3 (Always ON)                                                            Controllers User's Manual Basic Type (Cat. No. H156) for

          L H SP           SP L H             H SP L                                        H < 0, L < 0                 information on the operation of the standby sequence.
                                            H L SP                                                                  *7. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature
      H < 0, L > 0         H > 0, L < 0                                                     H < 0, L > 0
      H < L                H > L                                                            H  L                         Controllers User's Manual Basic Type (Cat. No. H156) for
                                                                                            H > 0, L < 0
                                                                                    SP H L  H  L                         information on the loop burnout alarm (LBA).
                                                                                                                    *8. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature
*3. Set value: 4, Upper- and lower-limit range
                                                                                                                         Controllers User's Manual Basic Type (Cat. No. H156) for

                                                                                                                         information on the PV change rate alarm.

      Case 1          Case 2               Case 3 (Always OFF)                              H < 0, L < 0
                                                  H SP L
             L H SP     SP L H                                                              H < 0, L > 0
        H < 0, L > 0     H > 0, L < 0          H L SP                                       H  L
         H < L           H > L                         SP H L                               H > 0, L < 0
                                                                                            H  L

*4. Set value: 5, Upper- and lower-limit with standby sequence
     For Upper- and Lower-Limit Alarm Described Above

      Case 1 and 2
      Always OFF when the upper-limit and lower-limit hysteresis
      overlaps.

      Case 3: Always OFF

                                                                                                                                                                                                8
                                                                                                                             E5CN/E5CN-U

Characteristics

Indication accuracy              Thermocouple: *1
                                   Terminal block models (E5CN): (0.3% of indicated value or 1C, whichever is greater) 1 digit max.
                                   Plug-in models (E5CN-U): (1% of indicated value or 2C, whichever is greater) 1 digit max.

                                 Platinum resistance thermometer input:
                                   Terminal block models (E5CN) and plug-in models (E5CN-U): (0.2% of indicated value or 0.8C, whichever is greater) 1 digit max.

                                 Analog input:
                                   Terminal block models (E5CN) and plug-in models (E5CN-U): 0.2% FS 1 digit max.

                                 CT input:
                                   Terminal block models (E5CN): 5% FS 1 digit max.

Influence of temperature *2      Thermocouple input (R, S, B, W, PL II):
Influence of voltage *2            Terminal block models (E5CN): (1% of PV or 10C, whichever is greater) 1 digit max.
                                   Plug-in models (E5CN-U): (2% of PV or 10C, whichever is greater) 1 digit max.

                                 Other thermocouple input: *3
                                   Terminal block models (E5CN): (1% of PV or 4C, whichever is greater) 1 digit max.
                                   Plug-in models (E5CN-U): (2% of PV or 4C, whichever is greater) 1 digit max.

                                 Platinum resistance thermometer input:

                                   Terminal block models (E5CN) and plug-in models (E5CN-U):
                                   (1% of PV or 2C, whichever is greater) 1 digit max.
                                 Analog input:
                                   Terminal block models (E5CN) and plug-in models (E5CN-U): (1%FS) 1 digit max.

Input sampling period            250 ms

Hysteresis                       Models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 EU (in units of 0.1 EU) *4
                                 Models with analog input: 0.01 to 99.99% FS (in units of 0.01% FS)

Proportional band (P)            Models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 EU (in units of 0.1 EU) *4
                                 Models with analog input: 0.1 to 999.9% FS (in units of 0.1% FS)

Integral time (I)                0 to 3999 s (in units of 1 s)

Derivative time (D)              0 to 3999 s (in units of 1 s) *5

Control period                   0.5, 1 to 99 s (in units of 1 s)

Manual reset value               0.0 to 100.0% (in units of 0.1%)

Alarm setting range              -1999 to 9999 (decimal point position depends on input type)

Affect of signal source          Thermocouple: 0.1C/ max. (100  max.)
resistance                       Platinum resistance thermometer: 0.1C/ max. (10  max.)

Insulation resistance            20 M min. (at 500 VDC)

Dielectric strength              2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge)

Vibration          Malfunction   10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
resistance         Destruction   10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions

Shock              Malfunction   100 m/s2, 3 times each in X, Y, and Z directions
resistance         Destruction   300 m/s2, 3 times each in X, Y, and Z directions

Weight             E5CN          Controller: Approx. 150 g, Mounting Bracket: Approx. 10 g
                   E5CN-U        Controller: Approx. 110 g, Mounting Bracket: Approx. 10 g

Degree of          E5CN          Front panel: IP66, Rear case: IP20, Terminals: IP00
protection         E5CN-U        Front panel: IP50, Rear case: IP20, Terminals: IP00

Memory protection                Non-volatile memory (number of writes: 1,000,000 times)

Setup Tool                       CX-Thermo version 4.0 or higher

Setup Tool port                  Provided on the bottom of the E5CN. Use this port to connect a computer to the E5CN when using the Setup Tool. An E58-CIFQ1
                                 USB-Serial Conversion Cable is required to connect the computer to the E5CN. *6

Standards          Approved      UL 61010-1, CSA C22.2 No. 1010-1, KOSHA certified (some models) *8
                   standards *7
                                 EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II, Lloyd's standards *9
                   Conformed
                   standards

                                 EMI:                                                 EN 61326

                                 Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A

                                 Noise Terminal Voltage:                              EN 55011 Group 1, class A

                                 EMS:                                                 EN 61326

                                 ESD Immunity:                                        EN 61000-4-2

EMC                              Electromagnetic Field Immunity:                      EN 61000-4-3

                                 Burst Noise Immunity:                                EN 61000-4-4

                                 Conducted Disturbance Immunity:                      EN 61000-4-6

                                 Surge Immunity:                                      EN 61000-4-5

                                 Power Frequency Magnetic Field Immunity:             EN 61000-4-8

                                 Voltage Dip/Interrupting Immunity:                   EN 61000-4-11

*1. The indication accuracy of K thermocouples in the -200 to 1300C range, T and N thermocouples at a temperature of -100C max., and U
     and L thermocouples at any temperatures is 2C 1 digit max. The indication accuracy of the B thermocouple at a temperature of 400C max.

     is not specified. The indication accuracy of B thermocouples in the 400 to 800C range is 3C max. The indication accuracy of the R and S

     thermocouples at a temperature of 200C max. is 3C 1 digit max. The indication accuracy of W thermocouples is 0.3 of PV or 3C,

     whichever is greater, 1 digit max. The indication accuracy of PL II thermocouples is 0.3 of PV or 2C, whichever is greater, 1 digit max.

*2. Ambient temperature: -10C to 23C to 55C, Voltage range: -15% to 10% of rated voltage
*3. K thermocouple at -100C max.: 10 max.
*4. "EU" stands for Engineering Unit and is used as the unit after scaling. For a temperature sensor, the EU is C or F.
*5. When robust tuning (RT) is ON, the differential time is 0.0 to 999.9 (in units of 0.1 s).
*6. External communications (RS-485) and cable communications for the Setup Tool can be used at the same time.
*7. The E5CN-U plug-in model is certified for UL listing only when used together with the OMRON P2CF-11 or P2CF-11-E Socket.

     The P3GA-11 is not certified for UL listing.

*8. Access the following website for information on certified models. http://www.ia.omron.com/support/models/index.html
*9. Refer to information on maritime standards in Safety Precautions for E5@N/E5@N-H for compliance with Lloyd's Standards.

                                                                                                                                                                       9
                                                                                                                                              E5CN/E5CN-U

USB-Serial Conversion Cable                                                 Current Transformer (Order Separately)
                                                                            Ratings
Applicable OS        Windows XP/Vista/7/8

Applicable software CX-Thermo version 4 or higher                           Dielectric strength 1,000 VAC for 1 min

Applicable models    E5AN/E5EN/E5CN/E5CN-U/E5AN-H/                          Vibration resistance 50 Hz, 98 m/s2
                     E5EN-H/E5CN-H/E5GN
                                                                                                                               E54-CT1: Approx. 11.5 g,
USB interface standard Conforms to USB Specification 1.1.                   Weight                                             E54-CT3: Approx. 50 g

DTE speed            38400 bps                                              Accessories                                        Armatures (2)
                                                                            (E54-CT3 only)                                     Plugs (2)
                     Computer: USB (type A plug)
Connector            Temperature Controller: Setup Tool port                Heater Burnout Alarms, SSR Failure
specifications       (on bottom of Controller)                              Alarms, and Heater Overcurrent Alarms

Power supply         Bus power (Supplied from USB host
                     controller.)
                                                                                                                                  Models with detection for single-phase
Power supply voltage 5 VDC                                                  CT input                                              heaters: One input
                                                                            (for heater current                                   Models with detection for single-phase
Current consumption 70 mA                                                   detection)                                            or three-phase heaters: Two inputs

Ambient operating    0 to 55C (with no condensation or icing)              Maximum heater current 50 A AC
temperature

Ambient operating    10% to 80%                                             Input current indication                              5% FS 1 digit max.
humidity                                                                    accuracy

Storage temperature  -20 to 60C (with no condensation or                   Heater burnout alarm                                  0.1 to 49.9 A (in units of 0.1 A)
                     icing)                                                 setting range *1                                      Minimum detection ON time: 100 ms

Storage humidity     10% to 80%                                             SSR failure alarm                                     0.1 to 49.9 A (in units of 0.1 A)
                                                                            setting range *2                                      Minimum detection OFF time: 100 ms
Altitude             2,000 m max.

Weight               Approx. 100 g                                          Heater overcurrent                                    0.1 to 49.9 A (in units of 0.1 A)

Note: A driver must be installed in the personal computer. Refer to         alarm setting range *3 Minimum detection ON time: 100 ms
        installation information in the operation manual for the
        Conversion Cable.                                                   *1. For heater burnout alarms, the heater current will be measured
                                                                                 when the control output is ON, and the output assigned to the
Communications Specifications                                                    alarm 1 function will turn ON if the heater current is lower than the
                                                                                 set value (i.e., heater burnout detection current value).
Transmission line    RS-485: Multipoint
connection method                                                           *2. For SSR failure alarms, the heater current will be measured when
                                                                                 the control output is OFF, and the output assigned to the alarm 1
Communications RS-485 (two-wire, half duplex)                                    function will turn ON if the heater current is higher than the set
                                                                                 value (i.e., SSR failure detection current value).
Synchronization      Start-stop synchronization
method                                                                      *3. For heater overcurrent alarms, the heater current will be
                                                                                 measured when the control output is ON, and the output assigned
Protocol             CompoWay/F, SYSWAY, or Modbus                               to the alarm 1 function will turn ON if the heater current is higher
                                                                                 than the set value (i.e., heater overcurrent detection current
                                                                                 value).

Baud rate            1200, 2400, 4800, 9600, 19200, 38400, or               Electrical Life Expectancy Curve for
                     57600 bps                                              Relays (Reference Values)

Transmission code ASCII

Data bit length * 7 or 8 bits                                               Life ( 104 operations)  500
                                                                                                     300
Stop bit length * 1 or 2 bits

Error detection      Vertical parity (none, even, odd)                                               100
                     Frame check sequence (FCS) with SYSWAY
                     Block check character (BCC) with                                                 50
                     CompoWay/F or CRC-16 Modbus                                                      30

Flow control         None

Interface            RS-485

Retry function       None                                                                            10

Communications       217 bytes                                                                       5       E5CN
buffer
                                                                                                     3       250 VAC, 30 VDC

Communications 0 to 99 ms                                                                                    (resistive load)
response wait time Default: 20 ms
                                                                                                             cos = 1

                                                                                                     1

* The baud rate, data bit length, stop bit length, and vertical parity can                                0  1        2        3  4  5        6
  be individually set using the Communications Setting Level.
                                                                                                                                  Switching current (A)

                                                                            Note: Do not connect a DC load to a Controller with a Long-life Relay
                                                                                    Output.

                                                                                                                                                                          10
                                                                                                                                                           E5CN/E5CN-U

External Connections

A voltage output (control output, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple,
  do not connect any of the control output terminals to ground. (If the control output terminals are connected to ground, errors will occur in the
  measured temperature values as a result of leakage current.)

Consult with your OMRON representative before using the external power supply for the ES1B for any other purpose.

E5CN

Controllers

                    Control output 1            The E5@N-@@@T@ is set for a K-type
          Long-life relay output                thermocouple (input type = 5) by default. An
          250 VAC, 3 A (resistive load)         input error (s.err) will occur if the input type
          Relay output                          setting does not agree with the temperature
          250 VAC, 3 A (resistive load)         sensor. Check the input type.
         Voltage output (for driving SSR)
          12 VDC, 21 mA                                          Control output 1                                   Auxiliary outputs (relay outputs)
          Current output                                                                                            250 VAC, 3 A
          0 to 20 mA DC                                      DO NOT DO NOT A                                        (resistive load)
          4 to 20 mA DC                                                                           Auxiliary outputs
          Load: 600  max.                                                                         (relay outputs)

                  Control output 2                                                                Auxiliary output 2
         Voltage output (for driving SSR)
         12 VDC, 21 mA                                                                            Auxiliary output 1

Option Units                                    mA USE           USE       B

                                                            V              B                           Input power supply                  A heater burnout alarm, heater short alarm,
                                                DO NOT                                                                                     heater overcurrent alarm, or input alarm is
                                                USE              TC/Pt                                    100 to 240 VAC                  sent to the output to which the alarm 1
                                                                 universal input                         24 VAC/VDC (no polarity)        function is assigned.
                                                  Analog input

        E53-CNHH03N2                       E53-CNHBN2                  E53-CNQ03N2                E53-CNPBN2                         E53-CNPHN2            E53-CNP03N2
        Communications                     Event inputs                Communications             Event Inputs and                   External Power        Communications (RS-485)
        (RS-485) and CT2                   and CT                      (RS-485) and               External Power Supply              Supply and CT         and External Power Supply
                                                                       Control Output 2
            B(+) 11                             11                                                       11              External +                          B(+)
                                                                           B(+) 11                                                                                  11
         RS-485                            EV1 12                                                 EV1 12                 power supply     11 12 VDC,
                                                                         RS-485                                                               20 mA        RS-485
            A(-) 12                                                                                                                -
                                                                           A(-) 12                                                        12                 A(-) 12
                    13
                                           EV2  13                  DO NOT 13                            13              DO NOT 13                         DO NOT 13
                                                                    USE                                                  USE
                                                                                                  EV2                                                      USE
                                                                           + 14
        CT2       14                                     14                                External +    14 12 VDC,                                        External+     14
                                           CT1                   Control output 2                                                                                            12 VDC,
             CT1                                                                           power supply      20 mA                     14                  power supply
                                                         15                - 15                                          CT1                                             15 20 mA
                  15                                                                                   - 15                                                         -
                                                                                                                                       15

         E53-CNH03N2                            E53-CN03N2            E53-CNBN2                     E53-CNQHN2            E53-CNQHHN2                      E53-CNQBN2
         Communications                         Communications        Event inputs                  Control Output 2      Control Output 2                 Event Inputs and
         (RS-485) and CT                        (RS-485)                                            and CT                and CT2                          Control Output 2
                                                                                   11
             B(+) 11                               B(+)                                                     + 11                   + 11                                       11
                                                           11         EV1 12
           RS-485                                                                                 Control output 2       Control output 2                            EV1 12
                                                RS-485                EV2          13                                                                            EV2 13
             A(-) 12                                                                                        - 12                   - 12
      DO NOT 13                                    A(-) 12                                                                                                            + 14
      USE                                                                                            DO NOT 13                             13
                                           DO NOT 13                                                 USE                                                    Control output 2
                     14                    USE                   DO NOT 14                                                           CT2    14
      CT1                                  DO NOT 14             USE                                                14                                                - 15
                                           USE                                                       CT1                                  CT1
                     15                    DO NOT 15             DO NOT 15                                                                        15
                                           USE                   USE                                                15

E5CN-U

                              The E5@N-@@@T@ is set for a                                                    Auxiliary output
                              K-type thermocouple (input type = 5)
                              by default. An input error (s.err) will                                        250 VAC, 3 A (resistive load)
                              occur if the input type setting does                                           (Relay outputs)
                              not agree with the temperature
                              sensor. Check the input type.

         Control output 1                                DO NOT  Control output 1                            Auxiliary output 1
                                                         USE                                                              Auxiliary output 2
      Relay output                         mA                       DO NOT A                                              (Control output (cooling side))
      (three terminals used)
      SPDT, 250 VAC, 3 A                                  V          USE                                                                               An input error is sent to the
      (resistive load)                        DO NOT                                                                                                   output to which the alarm 1
                                              USE                                B                                                                     function is assigned.
      Voltage output
      (for driving SSR)                        Analog input                       B                          Input power supply
       12 VDC, 21 mA                                                      TC/Pt
      Current output                                                      universal input                               100 to 240 VAC
       4 to 20 mA DC                                                                                                    24 VAC/VDC (no polarity)
       0 to 20 mA DC
       Load: 600 W max.

Note: For the Wiring Socket, purchase the P2CF-11 or PG3A-11 separately.

                                                                                                                                                                                        11
                                                                                                                       E5CN/E5CN-U

Isolation/Insulation Block Diagrams                                    E5CN-U

E5CN

                 *OQVU$5JOQVU2PVUQVU 065
                                                                      *OQVU2PVUQVU 065

                    $PNNVOJDBUJPOTFWFOUJOQVUT                                                                            $PVUQVU
                         &YUFSOBMQPXFSTVQQMZ
                                   $PVUQVU                                          1PXFS                               3PVUQVU
                                                                                    TVQQMZ                              :PVUQVU
                                   3PVUQVU                                                                      "VYJMJBSZPVUQVU
1PXFS                              :PVUQVU
TVQQMZ                     "VYJMJBSZPVUQVU

                                                                                              3FJOGPSDFEJOTVMBUJPO                'VODUJPOBMJOTVMBUJPO

        3FJOGPSDFEJOTVMBUJPO      'VODUJPOBMJOTVMBUJPO

Nomenclature                                                     Temperature unit

E5CN
E5CN-U

The front panel is the same for the E5CN and E5CN-U.

                              Operation indicators                                               No.1 display
                                           Level Key                                             No. 2 display

                                                                                                    Up Key

                                                                 Mode Key           Down Key

Dimensions                                                                                                                         (Unit: mm)

E5CN                                                                                                            Panel Cutout
Terminal Models
                                                         91                                 Mounted Separately                 Group Mounted
E5CN-U                                                78
Plug-in Models                    6                                                                                           (48 number of units - 2.5)+10.0
                                        1.5
                 48 48
                 48 48                                                                                                           45+00.6

                              58                                       44.8 44.8 48.8 60 min.                               Group mounting does not
                                                                                                                              allow waterproofing.

                                                                                                              45+00.6   Recommended panel thickness is 1 to
                                                                                                                         5 mm.
                              Waterproof Mounting Adapter        Terminal Cover                  45+00.6
                              Packing (Accessory)                (E53-COV17)                                           Group mounting is not possible in the
                              (Accessory)                        (Accessory)                                             vertical direction. (Maintain the specified
                                                                                                                         mounting space between Controllers.)
                                     Note: The terminal block cannot be removed.
                                                                                                                        To mount the Controller so that it is
                                                                                                                         waterproof, insert the waterproof packing
                                                                                                                         onto the Controller.

                                                                                                                        When two or more Controllers are
                                                                                                                         mounted, make sure that the surrounding
                                                                                                                         temperature does not exceed the
                                                                                                                         allowable operating temperature
                                                                                                                         specified in the specifications.

                                                                                                                Panel Cutout

                                  6                   (84.7)     14.2                       Mounted Separately                 Group Mounted

                                                      70.5                                                                    (48 number of units - 2.5)+10.0

                                                                                                                                   45+00.6

                              58                                       44.8 44.8

                                               Mounting Adapter                     60 min.                   45+00.6   Recommended panel thickness is 1 to 5
                                               (Accessory)                                           45+00.6             mm.

                                                                                                                        Group mounting is not possible in the
                                                                                                                         vertical direction. (Maintain the specified
                                                                                                                         mounting space between Controllers.)

                                                                                                                        When two or more Controllers are
                                                                                                                         mounted, make sure that the surrounding
                                                                                                                         temperature does not exceed the
                                                                                                                         allowable operating temperature specified
                                                                                                                         in the specifications.

                                                                                                                                                                      12
                                                                                                                                                     E5CN/E5CN-U

Accessories (Order Separately)                                                                                                              (2,100)  1,765
                                                                                                                      LED indicator (SD)
USB-Serial Conversion Cable
                                                                                                                      LED indicator (RD)                    Serial connector
E58-CIFQ1

                                                                                                                 250

                                                                                    USB connector (type A plug)

Terminal Cover                                    Waterproof Packing

E53-COV17                                         Y92S-29 (for DIN 48 48)

                        Note: The E53-COV10                                                                           Order the Waterproof Packing separately if it becomes lost or
                                 cannot be used.                                                                      damaged.
                                                                                                                      The Waterproof Packing can be used to achieve an IP66 degree of
                       48                                                                                             protection.
48.8                                                                                                                  (Deterioration, shrinking, or hardening of the waterproof packing may
                                                                                                                      occur depending on the operating environment. Therefore, periodic
22                                                                                                                   replacement is recommended to ensure the level of waterproofing
                                                                                                                      specified in IP66. The time for periodic replacement depends on the
                                                                                                                      operating environment. Be sure to confirm this point at your site.
                                                                                                                      Consider one year a rough standard. OMRON shall not be liable for
                                                                                                                      the level of water resistance if the customer does not perform periodic
                                                                                                                      replacement.)
                                                                                                                      The Waterproof Packing does not need to be attached if a waterproof
                                                                                                                      structure is not required.

9.1

                                                                                                                                                                                               13
                                                                                                                                                                                  E5CN/E5CN-U

Current Transformers                                                       21                               2.8                      E54-CT1
                                                                                                                       7.5           Thru-current (Io) vs. Output Voltage
E54-CT1                                                                    15    5.8 dia.                                            (Eo) (Reference Values)

                                                               25 3                                 10.5                             Maximum continuous heater current: 50 A (50/60 Hz)Output voltage (Eo) V (r.m.s.)
                                                                                                                                     Number of windings: 4002
                                                                       10  40                                                        Winding resistance: 182
                                                                                             Two, 3.5 dia.
E54-CT3                                                                                                                                    100 V 50 Hz

                                                                  40 40                                                                                                  10                                 Distortion
                                                                                                                                                                            1                                 factor 10%
                                                                                                                                                                                  1 k
                                                                                                                                                                     100 mV                                   3%
                                                                                                                                                                                                          1%

                                                                           30                                                                                        10                         100

                                                                                                              2.36 dia.                                              1                       RL = 10
                                                                           30
                                                                                                                                                                     100 V
                                                                                            12 dia.
                                                                                                                                  9

                                                                                                                                                                     10

                                                                                                                                                                     1            10 100 mA 1         10  100 1,000 A

                                                                                                                                                                                                Thru-current (Io) A (r.m.s.)

                                                                  Two, M3 (depth: 4)                                                 E54-CT3
                          15
                                                                                                                                     Thru-current (Io) vs. Output Voltage
                                                  30
                                                                                                                                     (Eo) (Reference Values)

                                                                                                                                     Maximum continuous heater current: 120 A (50/60 Hz)
                                                                                                                                     (Maximum continuous heater current for the
                                                                                                                                     Temperature Controller is 50 A.)
                                                                                                                                     Number of windings: 4002
                                                                                                                                     Winding resistance: 80.8

E54-CT3 Accessory         Connection Example                                                                                         Output voltage (Eo) V (r.m.s.)  100 V 50 Hz                             Distor-
                                                                                                                                                                        10                                   tion
Armature                                                                      Armature                                                                                 1        1 k                       factor
                                                                                                                                                                                                             10%
  Approx. 3 dia.                                                                                                                                                                  500
                                                                                                                                                                                                            3%
                                                                           Plug                                                                                                                           1%

                                                                                           Lead

                      18                                                                                                                                             100 mV                      100
                (22)                                                                                                                                                       10                   50
                                                                                                                                                                            1
                                                                                                                                                                                                RL = 10

Plug                                                                                                                                                               100 V

Approx. 6 dia.                                                                                                                                                            10
                                                                                                                                                                             1
                                                                                                                                                                                  10 100 mA  1        10  100 1,000 A

                                                                                                                                                                                                Thru-current (Io) A (r.m.s.)

                                                                                                                                                                                                                              14
                                                                                                                                                                                                 E5CN/E5CN-U

Adapter

Y92F-45  Note: 1. Note: 1. Use this Adapter when the panel has already been prepared for the E5B@.

         2. The Adapter is available only in black.                                                                                                                                  Fixture (Accessory)

                                                             4.7                                                                                             76

                                                                                                                                                             69.6 to 77.6

                 72 72

                                                                                                                                                                                     67 67 87

Mounted to E5CN                                                       Panel (1 to 8 mm)
                                                         48 48
                 72 72

                                                                                                                                                    2.2  4.7
                                                                                                                                                             77.3 (to back of E5CN)
DIN Track Mounting Adapter

Y92F-52 Note: This Adapter cannot be used together with the Terminal Cover.

                        Remove the Terminal Cover to use the Adapter.

                                                                                                                                                                 61

                                                                                                                                                                           3.5

                                                     50                                                                                                  38

Mounted to E5CN

                                                         48

                                                                                                                                                             100.5

                                                                                                                                                                                                              15
                                                                                                                                    E5CN/E5CN-U

E5CN-U Wiring Socket

Front-connecting Socket                                                                       Terminal Layout/Internal Connections
                                                                                                                (Top View)
P2CF-11  Eleven, M3.5 7.5                              3             4.5
                                                                                                                 8765
         sems screws                                7.8                                                                       4

                                                                                                                                     Mounting Holes

                                                                                                                                    Two, 4.5 dia. mounting holes

         70 max.                                                                        35.4

                                                    Two,                                         9          3                                  400.2
                                                    4.5-dia.
                                                    holes                                        10 11 1 2     Note: Can also be mounted to a DIN track.

                         4  50 max.

                                                            31.2 max.

Note: A model with finger protection (P2CF-11-E) is also available.

Back-connecting Socket
P3GA-11

                                           27 dia.                               4 73         Terminal Layout/Internal Connections
                            45                                                                                (Bottom View)
                                                                         25.6
                                              45                                                     5 678
                                                    4.5 16.3 6.2                                    4
                                                                             8.7
                                                                                                 3          9

                                                                                                    2 1 11 10

                                                                                              6

Note: 1. Using any other sockets will adversely affect accuracy. Use only the specified sockets.
        2. A Protective Cover for finger protection (Y92A-48G) is also available.

                                                                                                                                                                  16
                                              Terms and Conditions Agreement

Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.

Warranties.
(a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at
Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.

Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.
Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence
thereof.

Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability.

Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at
any time to confirm actual specifications of purchased Product.

Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.

OMRON Corporation                                                                                                                                        2014.4
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                                                   (c)Copyright OMRON Corporation 2014 All Right Reserved.