电子工程世界电子工程世界电子工程世界

型号

产品描述

搜索

E5CC-TRX3A5M-000

器件型号:E5CC-TRX3A5M-000
器件类别:热门应用    机电_工控_自动化   
厂商名称:OMRON
厂商官网:https://www.omron.com
下载文档

器件描述

Controllers Relay,3Aux AC

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Omron
产品种类:
Product Category:
Controllers
Analog / Digital:Digital
类型:
Type:
Programmable Temperature Controller
Display Type:11-Segment, 4 Digit
工作电源电压:
Operating Supply Voltage:
240 VAC
Mounting:Panel
大小:
Size:
48 mm x 48 mm
Number of Outputs:1
输出类型:
Output Type:
Relay
系列:
Series:
E5CC-T
商标:
Brand:
Omron Automation and Safety
工厂包装数量:
Factory Pack Quantity:
1
零件号别名:
Part # Aliases:
E5CCTRX3A5M000
单位重量:
Unit Weight:
4.232875 oz

E5CC-TRX3A5M-000器件文档内容

New Product

Digital Temperature Controller

E5@C/E5@C-T

Large White PV Display That's Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
New Plug-in Models That Are Convenient for Maintenance and Replacement
as replacing temperature controllers is possible without changing wiring.
New Models That Mount to DIN Track and Are Ideal for HMI/PLC Connections.
And Programmable Models to Support a Wider Range of Applications.

                                E5GC    DIN 48 24 mm

                                        page 2

Digital Temperature Controller  E5CC    DIN 48 48 mm
                                E5CC-U
    E5@C                        E5EC    page 16
    Series
                                E5AC    DIN 48 96 mm

                                        page 34

                                        DIN 96 96 mm

                                        page 34

                                E5DC    22.5 mm wide
                                        Mounts to DIN
                                        Track page 50

Programmable                    E5CC-T  DIN 48 48 mm
Temperature Controller          E5EC-T
(Digital Controller)            E5AC-T  page 64

   E5@C-T                               DIN 48 96 mm
   Series
                                        page 80

                                        DIN 96 96 mm

                                        page 80

                                                                           1
Digital Temperature Controller

E5GC (48 24 mm)

Easy Operation and High Performance of                                            48 24 mm            48 24 mm
the E5@C Series in a Compact 48 24-                                        Models with Screw  Models with Screwless
mm Body                                                                                         Clamp Terminal Blocks
                                                                              Terminal Blocks
A compact body of 48 24 90 mm (W H D) that is ideal for                  E5GC-@6               E5GC-@C
  small equipment, laboratory instruments, and others.
                                                                             Refer to your OMRON website for the most recent
White PV display with a height of 10.5 mm for high visibility even         information on applicable safety standards.
  with the compact body.
                                                                             Refer to Safety Precautions on page 104.
Removable terminal block to simplify maintenance. Select from
  screw terminals or screwless clamp terminals for the wiring
  method.

High-speed sampling at 50 ms.
Easy connections to a PLC with programless communications.
Set up the Controller without wiring the power supply by

  connecting to the computer with a Communications Conversion
  Cable (sold separately). Setup is easy with the CX-Thermo (sold
  separately).

Main I/O Functions

Sensor Input                                        E5GC                     Dual displays: PV/SV 4-digit displays
  Universal input
                                        PF (shift) Key                       Control Output 1
Thermocouple                         Temperature status display          Relay output
Pt                                    Simple programming                   Voltage output (for driving SSR)
Analog current/voltage                Independent heating and             Linear current output

          Indication Accuracy            cooling PID control                  Auxiliary Outputs
          Thermocouple input:         Changed parameter display            None
           0.3% of PV                  Display brightness setting          1
          Pt input: 0.2% of PV       Simple transfer output (only on     2
          Analog input: 0.2% of FS
                                         models with liner current outputs)
           Sampling Period             Work Bit Message
            50 ms

Event Inputs
None
1
2

Serial Communications
None
RS-485

       This datasheet is provided as a guideline for selecting products.
       Be sure to refer to the following manuals for application precautions and other information required for operation before attempting
       to use the product.
       E5@C Digital Temperature Controllers User's Manual (Cat. No. H174)
       E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)

2
                                                                                                                                   E5GC

Model Number Legend and Standard Models

Model Number Legend

E5GC-@@ @ @ @ M-@@@ (Example: E5GC-RX1A6M-015)

           -- - - - - ---
             A BC DE F

Model       A         B         C         D                         E        F                             Meaning
E5GC                                                                      Options
         Control    No. of    Power    Terminal                    Input
        outputs 1  auxiliary  supply      type                     type
                   outputs    voltage
          and 2

                                                                                                            48 24 mm

                                                                                     Control output 1                    Control output 2

    RX                                                                               Relay output                            None

    QX                                                                                Voltage output                         None
                                                                                     (for driving SSR)
*1 CX
               *2 0                                                                  Linear current output                   None
                   1
                   2                                                                                        None
                                  A
                                  D                                                                         1
                                                 6
                                                 C                                                          2
                                                                M
                                                                                                        100 to 240 VAC

                                                                                                            24 VAC/DC

                                                                                          Screw terminals (with cover)

                                                                                          Screwless clamp terminals

                                                                                                        Universal input

                                                                                     HB alarm and HS alarm Communications Event inputs

                                                                                000  ---                                ---        ---
                                                                                015
                                                                       *3 016        ---                          RS-485           ---
                                                                   *3, *4 023
                                                                       *5 024        ---                                ---                1

                                                                                     1                                  ---        ---

                                                                                     ---                                ---                2

*1 The control output can be used as a simple transfer output.
*2 Only option 000 can be selected if an auxiliary output is zero.
*3 Option 016 and 023 can be selected only if two auxiliary outputs are selected.
*4 Option with HB and HS alarms (023) cannot be selected if a linear current output is selected for the control output.
*5 Option 024 can be selected only if one auxiliary output is selected.

Heating and Cooling Control

Using Heating and Cooling Control

A Control Output Assignment
An auxiliary output is used as the cooling control output.
B Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.

                                                                                                                                              3
   E5GC

   Optional Products (Order Separately)                                  Waterproof Packing

   USB-Serial Conversion Cable                                                                 Model
                                                                                             Y92S-P12
                         Model                                           Note: This Waterproof Packing is provided with the Digital
                      E58-CIFQ2                                                  Temperature Controller.

   Communications Conversion Cable                                       Draw-out Jig

                         Model                                                                 Model
                                                                                              Y92F-55
                    E58-CIFQ2-E
                                                                         CX-Thermo Support Software
   Note: Always use this product together with the E58-CIFQ2.
           This Cable is used to connect to the bottom-panel Setup Tool                        Model
           port.                                                                          EST2-2C-MV4
                                                                         Note: CX-Thermo version 4.62 or higher is required for the E5GC.
   Current Transformers (CTs)                                                    For the system requirements for the CX-Thermo, refer to
                                                                                 information on the EST2-2C-MV4 on the OMRON website
   Hole diameter   Model                                                         (www.ia.omron.com).
       5.8 mm     E54-CT1
       12.0 mm    E54-CT3

   Mounting Adapter

                         Model
                   Y92F-53 (2pcs)
   Note: This Mounting Adapter is provided with the Digital Temperature
           Controller.

4
                                                         E5GC

Specifications

Ratings

Power supply voltage               A in model number: 100 to 240 VAC, 50/60 Hz
Operating voltage range            D in model number: 24 VAC, 50/60 Hz; 24 VDC
Power consumption
                                   85% to 110% of rated supply voltage
Sensor input
                                   5.9 VA max. at 100 to 240 VAC, and 3.2 VA max. at 24 VAC or 1.8 W max. at 24 VDC
Input impedance
                                   Temperature input
Control method                          Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
                                        Platinum resistance thermometer: Pt100 or JPt100
Control    Relay output                 Infrared temperature sensor (ES1B): 10 to 70C, 60 to 120C, 115 to 165C, or 140 to 260C
output
           Voltage output          Analog input
Auxiliary  (for driving SSR)            Current input: 4 to 20 mA or 0 to 20 mA
output     Linear current output        Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
           Number of outputs
                                   Current input: 150  max., Voltage input: 1 M min. (Use a 1:1 connection when connecting the ES2-HB/
           Output specifications   THB.)

Event      Number of inputs        ON/OFF control or 2-PID control (with auto-tuning)
input
           External contact input  SPST-NO, 250 VAC, 2 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5
           specifications          V, 10 mA (reference value)

Setting method                     Output voltage 12 VDC 20% (PNP), max. Load current: 21 mA, with short-circuit protection circuit
Indication method
                                   4 to 20 mA DC/0 to 20 mA DC, load: 500  max., resolution: Approx. 10,000
Multi SP                           1 or 2 (depends on model)
Bank switching
                                   SPST-NO relay outputs, 250 VAC, 2 A (resistive load),
Other functions                    Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value)

Ambient operating temperature      1 or 2 (depends on model)
                                   Contact input ON: 1 k max., OFF: 100 k min.
Ambient operating humidity         Non-contact input ON: Residual voltage 1.5 V max.; OFF: Leakage current 0.1 mA max.
Storage temperature
Altitude                           Current flow: approx. 7 mA per contact
Recommended fuse
Installation environment           Digital setting using front panel keys

                                   11-segment digital displays and individual indicators
                                   Character height: PV: 10.5 mm, SV: 5.0 mm

                                   Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or
                                   serial communications.*

                                   None

                                   Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burn-
                                   out (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self
                                   tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change
                                   rate limit, logic operations, temperature status display, simple programming, moving average of input val-
                                   ue, display brightness setting, simple transfer output, and work bit message
                                   -10 to 55C (with no condensation or icing), For 3-year warranty: -10 to 50C with standard mounting (with
                                   no condensation or icing)

                                   25% to 85%
                                   -25 to 65C (with no condensation or icing)
                                   2,000 m max.

                                   T2A, 250 VAC, time-lag, low-breaking capacity

                                   Installation Category II, Pollution Degree 2 (IEC 61010-1 compliant)

* Only four set points are selectable for event inputs.

                                                                                                                                                5
   E5GC

   Input Ranges

   Thermocouple/Platinum Resistance Thermometer (Universal inputs)

    Sensor                                  Platinum resistance                                                         Thermocouple                                                          Infrared temperature
      type                                       thermometer                                                                                                                                           sensor

    Sensor                                       Pt100            JPt100               K            J          T        EL                    U          N       R     S     B     W    PLII  10 to 60 to 115 to 140 to
   specifica-                                                                                                                                                                                 70C 120C 165C 260C
                                                                                               850                                                              1700  1700  1800  2300  1300
       tion         Temperature range (C)                                     1300                     400.0                                            1300
                                                                                                                                                                  0     0   100     0     0
                2300                        850                                                -100 -20.0                               850
                1800                                                                                                                                            16    17    18    19    20
                1700                             500.0          500.0                  500.0    78                                 600
                1600                                                                                           400 400.0
                1500                                                                                                                          400 400.0
                1400
                1300                                     100.0          100.0                                                                                                                                               260
                1200                                                                                                                                                                                   120 165
                1100                                                                                                                                                                          90
                1000
                                                         0.0            0.0                                                                                                                   0  0  0  0
                 900
                 800                                                                    -20.0                                           -100
                 700                                                           -200
                 600                        -200 -199.9         -199.9                                         -200 -199.9 -200               -200 -199.9 -200
                 500                                                            56
                 400                        01234                                                              9 10 11 12 13 14 15                                                            21 22 23 24
                 300
                 200
                 100

                -100
                -200

   Set value

                                            Shaded settings are the default settings.

   The applicable standards for the input types are as follows:                                    JPt100: JIS C 1604-1989, JIS C 1606-1989
   K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 60584-1                                            Pt100: JIS C 1604-1997, IEC 60751
   L: Fe-CuNi, DIN 43710-1985                                                                      PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)
   U: Cu-CuNi, DIN 43710-1985
   W: W5Re/W26Re, ASTM E988-1990

   Analog input

         Input type                                               Current                                      Voltage
   Input specification
                                                         4 to 20 mA 0 to 20 mA 1 to 5 V 0 to 5 V                        0 to 10 V
   Setting range                                                                                                            29
                                                         Usable in the following ranges by scaling:
   Set value                                             -1999 to 9999, -199.9 to 999.9,
                                                         -19.99 to 99.99 or -1.999 to 9.999

                                                              25               26              27              28

6
                                                                                                                                                        E5GC

Alarm Types

Each alarm can be independently set to one of the following 17 alarm types. The default is 2: Upper limit. (See note.)
Auxiliary outputs are allocated to alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not

        displayed.
        To use alarm 1, set the output assignment to alarm 1.

Set                                                     Alarm output operation
value
               Alarm type              When alarm value X When alarm value X                                     Description of function

                                            is positive                       is negative

0 Alarm function OFF                                              Output OFF                         No alarm

1          Upper- and lower-limit *1   ON                LH                                          Set the upward deviation in the set point for the alarm upper
                                       OFF                                                           limit (H) and the lower deviation in the set point for the alarm
                                                         SP       PV *2                              lower limit (L). The alarm is ON when the PV is outside this
                                                                                                     deviation range.

    2      Upper-limit                 ON                      X         ON   X                  Set the upward deviation in the set point by setting the alarm
(default)                              OFF                                                 PV value (X). The alarm is ON when the PV is higher than the
                                                         SP       PV     OFF  SP                     SP by the deviation or more.

                                       ON                X               ON         X                Set the downward deviation in the set point by setting the

3 Lower-limit                          OFF                        PV     OFF               PV alarm value (X). The alarm is ON when the PV is lower than
                                                           SP
                                                                              SP                     the SP by the deviation or more.

4          Upper- and lower-limit      ON                LH                                          Set the upward deviation in the set point for the alarm upper
           range *1                    OFF                                                           limit (H) and the lower deviation in the set point for the alarm
                                                         SP       PV *3                              lower limit (L). The alarm is ON when the PV is inside this de-
                                                                                                     viation range.

5          Upper- and lower-limit      ON                LH       PV *4                              A standby sequence is added to the upper- and lower-limit
                                                          SP                                         alarm (1). *6
           with standby sequence *1 *5 OFF

6          Upper-limit with standby    ON                      X         ON   X            PV A standby sequence is added to the upper-limit alarm (2). *6
           sequence                    OFF
                                                         SP       PV     OFF  SP

7          Lower-limit with standby ON                   X               ON       X
                                                          SP
           sequence                    OFF                        PV     OFF            PV A standby sequence is added to the lower-limit alarm (3). *6

                                                                              SP

8          Absolute-value upper-lim- ON                     X            ON      X                   The alarm will turn ON if the process value is larger than the

           it                          OFF                        PV     OFF           0 PV alarm value (X) regardless of the set point.
                                                      0

9          Absolute-value lower-limit  ON                   X            ON      X                   The alarm will turn ON if the process value is smaller than the
                                       OFF
                                            0                     PV     OFF           0 PV alarm value (X) regardless of the set point.

10         Absolute-value upper-lim- ON                     X            ON      X                   A standby sequence is added to the absolute-value upper-

           it with standby sequence OFF 0                         PV     OFF           0 PV limit alarm (8). *6

11         Absolute-value lower-limit ON                    X            ON      X                   A standby sequence is added to the absolute-value lower-

           with standby sequence       OFF                        PV     OFF           0 PV limit alarm (9). *6
                                                      0

12 LBA (alarm 1 type only)                                            -                              *7

13 PV change rate alarm                                               -                              *8

14         SP absolute-value           ON        X                       ON      X                   This alarm type turns ON the alarm when the set point (SP)
           upper-limit alarm           OFF  0
                                                                  SP     OFF           0 SP is higher than the alarm value (X).

15         SP absolute-value           ON                   X            ON      X                   This alarm type turns ON the alarm when the set point (SP)
           lower-limit alarm                                             OFF                     SP  is lower than the alarm value (X).
                                       OFF  0                     SP
                                                                                      0

                                       Standard Control                  Standard Control

                                       ON                   X            ON      X

                                       OFF                        MV     OFF               MV
                                                      0
           MV absolute-value                                                           0             This alarm type turns ON the alarm when the manipulated
           upper-limit alarm *9
16                                     Heating/Cooling                   Heating/Cooling             variable (MV) is higher than the alarm value (X).

                                       Control (Heating MV) Control (Heating MV)

                                       ON                   X

                                       OFF                        MV Always ON
                                                      0

                                       Standard Control Standard Control

                                       ON                   X            ON      X

                                       OFF  0                     MV     OFF           0   MV

17         MV absolute-value           Heating/Cooling                   Heating/Cooling             This alarm type turns ON the alarm when the manipulated
           lower-limit alarm *9        Control (Cooling MV)              Control (Cooling MV)        variable (MV) is lower than the alarm value (X).

                                       ON                   X

                                       OFF                        MV Always ON
                                                      0

                                                                                                                                                                       7
   E5GC

   *1 With set values 1, 4, and 5, the upper- and lower-limit values can  *4 Set value: 5, Upper- and lower-limit with standby sequence
        be set independently for each alarm type, and are expressed as         For Upper- and Lower-Limit Alarm Described Above at *2
        "L" and "H."                                                            In cases 1 and 2 above, the alarm is always OFF if the upper-

   *2 Set value: 1, Upper- and lower-limit alarm                                   and lower-limit hysteresis overlaps.

   Case 1     Case 2        Case 3 (Always OFF)                                 In case 3, the alarm is always OFF.

   L H SP     SP L H          H SP L               H<0, L<0               *5 Set value: 5, Upper- and lower-limit alarm with standby sequence
                            H L SP                                             The alarm is always OFF if upper- and lower-limit hysteresis
   H<0, L>0    H>0, L<0                           H<0, L>0                     overlaps.
   |H| < |L|    |H| > |L|                          |H|  |L|
                                                   H>0, L<0               *6 Refer to the E5@C Digital Temperature Controllers User's Manual
                            SP H L                  |H|  |L|                   (Cat. No. H174) for information on the operation of the standby
                                                                               sequence.
   *3 Set value: 4, Upper- and lower-limit range  H<0, L<0
                                                  H<0, L>0                *7 Refer to the E5@C Digital Temperature Controllers User's Manual
   Case 1     Case 2        Case 3 (Always ON)     |H|  |L|                    (Cat. No. H174) for information on the LBA.
                                                  H>0, L<0
    L H SP    SP L H          H SP L               |H|  |L|               *8 Refer to the E5@C Digital Temperature Controllers User's Manual
                            H L SP                                             (Cat. No. H174) for information on the PV change rate alarm.
   H<0, L>0     H>0, L<0
   |H| < |L|     |H| > |L|                                                *9 When heating/cooling control is performed, the MV absolute-
                                                                               value upper-limit alarm functions only for the heating operation
                            SP H L                                             and the MV absolute-value lower-limit alarm functions only for the
                                                                               cooling operation.

8
                                                                                                                             E5GC

Characteristics

                                   Thermocouple: (0.3 % of indication value or 1C, whichever is greater) 1 digit max.*1

Indication accuracy                Platinum resistance thermometer: (0.2 % of indication value or 0.8C, whichever is greater) 1 digit max.
(at the temperature of 23C)
                                   Analog input:    0.2% FS 1 digit max.

                                   CT input:        5% FS 1 digit max.

Influence of temperature *2        Thermocouple input (R, S, B, W, PL II): (1% of indication value or 10C, whichever is greater) 1 digit
Influence of voltage *2            max.
                                   Other thermocouple input: (1% of indication value or 4C, whichever is greater) 1 digit max. *3
                                   Platinum resistance thermometer: (1% of indication value or 2C, whichever is greater) 1 digit max.
                                   Analog input: 1% FS 1 digit max.
                                   CT input: 5% FS 1 digit max.

Input sampling period              50 ms

Hysteresis                         Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                   Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

Proportional band (P)              Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                   Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I)                  0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D)                0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Proportional band (P) for cooling  Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                   Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I) for cooling      0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D) for cooling    0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Control period                     0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)

Manual reset value                 0.0% to 100.0% (in units of 0.1%)

Alarm setting range                -1,999 to 9,999 (decimal point position depends on input type)

Influence of signal source resis-  Thermocouple: 0.1C/ max. (100  max.), Platinum resistance thermometer: 0.1C/ max. (10  max.)
tance

Insulation resistance              20 M min. (at 500 VDC)

Dielectric strength                100 to 240 VAC: 3,000 VAC, 50/60 Hz for 1 min between terminals of different charge
                                   24 VAC/DC: 2,300 VAC, 50/60 Hz for 1 min between terminals of different charge

                 Malfunction       10 to 55 Hz, 20 m/s2 for 10 min each in X, Y and Z directions
Vibration                          10 to 55 Hz, 20 m/s2 for 2 hr each in X, Y, and Z directions

                 Resistance

Shock       Malfunction            100 m/s2, 3 times each in X, Y, and Z directions
            Resistance             300 m/s2, 3 times each in X, Y, and Z directions

Weight                             Controller: Approx. 80 g, Adapter: Approx. 4 g 2

Degree of protection               Front panel: IP66, Rear case: IP20, Terminals: IP00

Memory protection                  Non-volatile memory (number of writes: 1,000,000 times)

Setup Tool                         CX-Thermo version 4.62 or higher

Setup Tool port                    E5GC side panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect a USB port on the com-
                                   puter. *5
                                   E5GC bottom panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion Cable
                                   are used together to connect a USB port on the computer.*5

                 Approved standards UL 61010-1, Korean Radio Waves Act (Act 10564)
Standards

                 Conformed standards EN 61010-1 (IEC 61010-1): Pollution Degree 2 , overvoltage category II

                                   EMI:                                                 EN61326

                                   Radiated Interference Electromagnetic Field Strength: EN55011 Group 1, class A

                                   Noise Terminal Voltage:                              EN55011 Group 1, class A

                                   EMS:                                                 EN61326

EMC                                ESD Immunity:                                        EN61000-4-2

                                   Electromagnetic Field Immunity:                      EN61000-4-3

                                   Burst Noise Immunity:                                EN61000-4-4

                                   Conducted Disturbance Immunity:                      EN61000-4-6

                                   Surge Immunity:                                      EN61000-4-5

                                   Voltage Dip/Interrupting Immunity:                   EN61000-4-11

*1 The indication accuracy of K thermocouples in the -200 to 1,300C range, T and N thermocouples at a temperature of -100C max., and U
     and L thermocouples at any temperature is 2C 1 digit max. The indication accuracy of B thermocouples at a temperature of 400C max. is
     not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800C is 3C max.
     The indication accuracy of R and S thermocouples at a temperature of 200C max. is 3C 1 digit max. The indication accuracy of W
     thermocouples is (0.3% of PV or 3C, whichever is greater) 1 digit max.
     The indication accuracy of PLII thermocouples is (0.3% of PV or 2C, whichever is greater) 1 digit max.

*2 Ambient temperature: -10C to 23C to 55C, Voltage range: -15% to 10% of rated voltage
*3 K thermocouple at -100C max.: 10C max.
*4 The unit is determined by the setting of the Integral/Derivative Time Unit parameter.

*5 External serial communications (RS-485) and USB-Serial Conversion Cable communications can be used at the same time.

                                                                                                                                                9
E5GC

USB-Serial Conversion Cable                                                                                       When Digital Temperature Controllers are connected, set
                                                                                                                  points and RUN/STOP commands can be sent from the Dig-
    Applicable OS           Windows XP/Vista/7/8                                  Component                       ital Temperature Controller that is set as the master to the
                                                                                  Communica-                      Digital Temperature Controllers that are set as slaves.
    Applicable software CX-Thermo version 4.62 or higher                          tions                           Slope and offsets can be set for the set point.
                                                                                                                  Number of connected Digital Temperature Controllers: 32
    Applicable models       E5@C-T Series, E5@C Series, and E5CB Series                                           max. (including master)

    USB interface standard Conforms to USB Specification 2.0

    DTE speed               38,400 bps                                            Copying*                        When Digital Temperature Controllers are connected, the pa-
                            Computer: USB (Type A plug)                                                           rameters can be copied from the Digital Temperature Control-
    Connector               Digital Temperature Controller: Special serial con-                                   ler that is set as the master to the Digital Temperature
    specifications          nector                                                                                Controllers that are set as slaves.
                            Bus power (Supplied from the USB host controller) *
    Power supply            5 VDC                                                 MELSEC is a registered trademark of Mitsubishi Electric Corporation.
    Power supply voltage    450 mA max.                                           KEYENCE is a registered trademark of Keyence Corporation.
    Current consumption     4.70.2 VDC (Supplied from USB-Serial Conver-
                            sion Cable to the Digital Temperature Controller.)    * Both the programless communications and the component communications
    Output voltage          250 mA max. (Supplied from USB-Serial Conver-             support the copying.
                            sion Cable to the Digital Temperature Controller.)
    Output current                                                                Current Transformer (Order Separately)
                            0 to 55C (with no condensation or icing)             Ratings
    Ambient operating
    temperature             10% to 80%                                            Dielectric strength                             1,000 VAC for 1 min
    Ambient operating                                                             Vibration resistance
    humidity                -20 to 60C (with no condensation or icing)           Weight                                          50 Hz, 98 m/s2
    Storage temperature     10% to 80%
    Storage humidity        2,000 m max.                                          Accessories (E54-CT3 only)                      E54-CT1: Approx. 11.5 g,
    Altitude                Approx. 120 g                                                                                         E54-CT3: Approx. 50 g
    Weight
                                                                                                                                  Armatures (2)
                                                                                                                                  Plugs (2)

Windows is a registered trademark of Microsoft Corporation in the                 Heater Burnout Alarms and SSR Failure
                                                                                  Alarms
United States and or other countries.
                                                                                  CT input (for heater current Models with detection for single-phase heat-
* Use a high-power port for the USB port.
                                                                                  detection)                                      ers: One input
Note: A driver must be installed on the computer. Refer to the
        Instruction Manual included with the Cable for the installation           Maximum heater current                          50 A AC
        procedure.
                                                                                  Input current                                   5% FS 1 digit max.
Communications Specifications                                                     indication accuracy
                                                                                                                                  0.1 to 49.9 A (in units of 0.1 A)
    Transmission line connection  RS-485: Multidrop                               Heater burnout alarm                            Minimum detection ON time: 100 ms *3
    method                                                                        setting range *1                                0.1 to 49.9 A (in units of 0.1 A)
                                                                                                                                  Minimum detection OFF time: 100 ms *4
                                                                                  SSR failure alarm setting
                                                                                  range *2

    Communications                RS-485 (two-wire, half duplex)                  *1 For heater burnout alarms, the heater current will be measured when the
                                                                                       control output is ON, and the output will turn ON if the heater current is
    Synchronization method        Start-stop synchronization                           lower than the set value (i.e., heater burnout detection current value).

    Protocol                      CompoWay/F, or Modbus                           *2 For SSR failure alarms, the heater current will be measured when the
                                                                                        control output is OFF, and the output will turn ON if the heater current is
    Baud rate*                    9,600, 19,200, 38,400, or 57,600 bps                  higher than the set value (i.e., SSR failure detection current value).

    Transmission code             ASCII                                           *3 The value is 30 ms for a control period of 0.1 s or 0.2 s.
                                                                                  *4 The value is 35 ms for a control period of 0.1 s or 0.2 s.
    Data bit length *             7 or 8 bits

    Stop bit length *             1 or 2 bits                                     Electrical Life Expectancy Curve for
                                                                                  Control Output Relay (Reference Values)
    Error detection               Vertical parity (none, even, odd)
                                  Block check character (BCC)                            500
                                  with CompoWay/F or                                     300Life ( 104 operations)
                                  CRC-16 with Modbus                                     200

    Flow control                  None

    Interface                     RS-485

    Retry function                None                                                                     100
                                                                                                                                                          E5GC
    Communications buffer         217 bytes
                                                                                                                                  250 VAC, 30 VDC
    Communications response       0 to 99 ms                                                               50
    wait time                     Default: 20 ms                                                                                  (resistive load)

                                                                                                           30                     cos = 1

* The baud rate, data bit length, stop bit length, and vertical parity can                                 20
  be individually set using the Communications Setting Level.
                                                                                                           10
Communications Functions

    Programless     You can use the memory in the PLC to read and write E5@C                               5      0.2 0.3 0.5  1  23 5                          10
    communica-      parameters, start and stop operation, etc.
    tions           The E5@C automatically performs communications with                                    3
                    PLCs. No communications programming is required.                                       2
                    Number of connected Digital Temperature Controllers: 32
                    max. (Up to 16 for the FX Series)                                                      1
                    Applicable PLCs: OMRON PLCs                                                              0.1

                               CS Series, CJ Series, or CP Series                                                                 Switching current (A)
                        Mitsubishi Electric PLCs

                               MELSEC Q Series, L Series, or FX Series (compati-
                               ble with the FX2 or FX3 (excluding the FX1S))
                        KEYENCE PLCs
                               KEYENCE KV Series

10
                                                                                                                                                               E5GC

External Connections

E5GC

    Control Outputs                       Auxiliary outputs 1, 2                               E5GC-@ @ @ @ @ M - @ @ @

Relay output                            Relay outputs                                                                (1) (2)(3)(4)(5) (6)
250 VAC, 2 A                             250 VAC, 2 A                                                                          
(resistive load)                         (resistive load)
                                                                                                                       Terminal type
Voltage output (for driving SSR)
12 VDC, 21 mA                                                       The E5GC is set for a K-type thermocouple (input type = 5) by
Linear current output                                                default. An input error (s.err) wil occur if the input type setting
0 to 20 mA DC                                                       does not agree with the temperature sensor. Check the input type.
4 to 20 mA DC
Load: 500  max.

                                  (6) Options                                                                                       (5) Sensor
                                                                                                                                        (Temperature/
                                  015                     016            023                                  024                       Analog) Input

                                  Communications          Event input 1  CT input                             Event inputs 1 and 2
                                  (RS-485)                      -+
                                                                                 CT                           EV2  -     +                      -           +
                                                          EV1
                                        RS-485                                                                EV1     +
                                                              789
                                  B(+)          A(-)

                                                                                                                                    TC 10 11 12

                                        789                                  789                                   789

                                                                                                                                                A BB

                                  (3) Input Power Supply                                                                            Pt 10 11 12

                                  100 to 240 VAC 24 VAC/DC                                                                                 + mA -

                                        12                12                         7 8 9 10 11 12                                  I 10 11 12
                                                                                     123456
                                                      (no polarity)                                                                               - V+

                                                                                                                                    V 10 11 12

                                                                                                                         (2) Auxiliary Outputs

                                  (1) Control Outputs                                                                    Auxiliary  Auxiliary outputs 1, 2
                                                                                                                         output 1             Auxiliary
                                                                                                                                              output 2
                                  RX                  QX                 CX
                                                                                                                                      9
                                  Relay output        Voltage output (for driving SSR) Linear current output
                                           R
                                                                  Q          C

                                                          +-                 +-

                                        34                34                 34                                            56             56

                                                                                                                         Auxiliary  Auxiliary
                                                                                                                         output 1   output 1

Note: 1. The application of the terminals depends on the model.
        2. Do not wire the terminals that are shown with a gray background.
        3. When complying with EMC standards, the cable that connects the sensor must be 30 m or less.
            If the cable length exceeds 30 m, compliance with EMC standards will not be possible.
        4. Connect M3 crimped terminals.

Isolation/Insulation Block Diagrams

      Power                       Sensor input and CT input
      supply                   Communications and event inputs
              Voltage output (for driving SSR) and linear current output

                                            Relay output
                                    Auxiliary outputs 1 and 2

                             : Reinforced insulation
                             : Functional isolation

Note: Auxiliary outputs 1 to 2 are not insulated.

                                                                                                                                                               11
E5GC                                                                   E5GC-@C
Wiring Methods                                                         Controllers with Screwless Clamp Terminal Blocks

E5GC-@6
Controllers with Screw Terminal Blocks (M3 Screws)

              Controllers with Screw Terminal Blocks                                                           Controllers with Screwless Clamp Terminals Blocks
               Terminal type: Forked or round crimped terminals                                                Wire stripping length: 8 to 12 mm
               Tightening torque for all terminals: 0.43 to 0.58 Nm                                           Ferrules: 8 to 12 mm

                                                    5.8 mm max.                                                                                     0.8 to 1.4 mm

                                                    5.8 mm max.                                                8 to 12 mm                      8 to 12 mm

Wires: AWG24 to AWG18 (equal to a cross-sectional area of 0.205 to 0.823 mm2) braided or solid wires

Nomenclature

E5GC                        Front panel                                                                            Left Side View of the E5GC

         Temperature unit                                                No. 1 display                                                         Left-panel
      Operation indicators                                             PV or specified parameter                                               Setup Tool
                                                                                                                                               port
                                                                          No.2 display
                                                                       SP or specified parameter value Bottom View of E5GC

      Press O Key once to go to Adjustment Level.                      Use the U D Keys to set the parameter.  Bottom-panel Setup
                                                                                                               Tool port
      Press O Key for at least 3 seconds                             Use S Key to change the
      to go to the Initial Setting Level.                            digit (default setting).

                                            Use the M Key to change
                                            to another parameter.

12
Dimensions                                                                                                                                                   E5GC

Controllers                                                                                                                                                  (Unit: mm)

E5GC-@6                              63.6             4                     Waterproof Packing (Accessory)
Controllers with Screw
Terminal Blocks                                                             Mounting Adapter (Accessory)
                                                                                                                   Terminal Cover (Accessory)
                                     48
                                                                            90
                                                                                                                            44.8

                                                         1

                        24                            40.8                                        22                                                 22

Use two Mounting Adapters, either on the top and bottom or on the right and left.

Setup Tool ports are provided as standard feature. Use these ports to connect a computer to the Digital Temperature Controller. The E58-
  CIFQ2 USB-Serial Conversion Cable is required to connect to the port on the side panel. The E58-CIFQ2 USB-Serial Conversion Cable
  and E58-CIFQ2-E Communications Conversion Cable are required to connect to the port on the bottom panel. (You cannot leave either
  port connected constantly during operation.)

             Mounted Separately                     Horizontally Group Mounted

                                                                        L1

                                                                            22.2+00.3         To mount the Temperature Controller so that it is waterproof,
                                                                                              insert the Waterproof Packing onto the Temperature Controller.
40 min                  45+0.60                       L1=(48n-2.5)   +1.0                    Group mounting does not allow waterproofing.
                                                                      +0

                                                  n: Number of mounted Controllers (2  n  6)
                                     22.2+00.3

To install the Temperature Controller, insert it into a square hole in a panel with a thickness of 1 to 8 mm, and then insert the enclosed
  adapter so that it locks into the grooves on the top and bottom or on the left and right of the rear case.

Tighten the two mounting screws on the top and bottom or on the right and left of the Mounting Adapters alternately little by little to main-
  tain a balance, and tighten them to a torque of between 0.29 and 0.39 Nm.

When two or more Temperature Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable
  operating temperature range given below.

   Horizontal group mounting: -10 to 55C
Use Temperature Controllers with Screwless Clamp Terminal Blocks for vertical group mounting.

E5GC-@C                                         63.6            4                             Waterproof Packing (Accessory)
Controllers with Screwless                                                                    Mounting Adapter (Accessory)
Clamp Terminal Blocks                           48
                                                                                              93
                                                                                                                                               44.8

                                                                   1

                                 24                         40.8                                             22                                          22

Use two Mounting Adapters, either on the top and bottom or on the right and left.

Setup Tool ports are provided as standard feature. Use these ports to connect a computer to the Digital Temperature Controller. The E58-
  CIFQ2 USB-Serial Conversion Cable is required to connect to the port on the side panel. The E58-CIFQ2 USB-Serial Conversion Cable
  and E58-CIFQ2-E Communications Conversion Cable are required to connect to the port on the bottom panel. (You cannot leave either
  port connected constantly during operation.)

             Mounted Separately                 Horizontally Group Mounted                    Vertically Group Mounted

                                                            L1                                45  +0.6
                                                                                                  +0

                                                                            22.2+00.3                              To mount the Temperature Controller so

40 min                                                                                                             that it is waterproof, insert the Waterproof

                        45+0.60                       L1=(48n-2.5)   +1.0                                         Packing onto the Temperature Controller.
                                                                      +0

                                                n: Number of mounted Controllers (2  n  6)                   L2    Group mounting does not allow waterproof-

                                     22.2+00.3                                                                     ing.

                                                                                              L2=(24n-1.5)  +1.0
                                                                                                             +0

To install the Temperature Controller, insert it into a square hole in a panel with a thickness of 1 to 8 mm, and then insert the enclosed

             adapter so that it locks into the grooves on the top and bottom or on the left and right of the rear case.

Tighten the two mounting screws on the top and bottom or on the right and left of the Mounting Adapters alternately little by little to main-
  tain a balance, and tighten them to a torque of between 0.29 and 0.39 Nm.

When two or more Temperature Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable
  operating temperature range given below.

             Horizontal group mounting: -10 to 55C

             Vertical group mounting of two Controllers: -10 to 45C

             Vertical group mounting of three or more Controllers: -10 to 40C

If you use vertical group mounting, you cannot draw out the interior body of the Controller.

                                                                                                                                                                 13
E5GC

Accessories (Order Separately)

USB-Serial Conversion Cable                                                                                                                        (2110)
                                                                                                                                                                                   263
E58-CIFQ2                                                                           250                                                                                                                     1510
                                                                                                                               LED (RD)                                                                                Serial connector

                                                                     USB connector                                                                                                                           1510
                                                                     (type A plug)

                                                                                                                                                               LED (PWR)
                                                                                                                                                               LED (SD)

Conversion Cable                                                          Connecting to the E58-CIFQ2 USB-Serial Conversion Cable
E58-CIFQ2-E
                                                                                                                                                               (2110)
           Conversion Cable
                                                                                         250                                                                                263
                                          (1510)

Note: Always use this product together with the E58-CIFQ2.                                                                     E58-CIFQ2 (Order separately)                                         Conversion Cable

Current Transformers                                                      21                                                  Thru-current (Io) vs. Output Voltage (Eo) (Reference Values)
E54-CT1
                                                                           15  5.8 dia.                     2.8                E54-CT1
                                                               25 3                                                    7.5
                                                                                                                               Maximum continuous heater current: 50 A (50/60 Hz)

                                                                                                                               Number of windings:                                                4002

                                                                                                                               Winding resistance:                                                182

                                                                                                                               Output voltage (Eo) V (r.m.s.)  100V Frequency: 50 Hz

                                                                                                    10.5                                                             10                             Distortion
                                                                                                                                                                      1
                                                                           40                                                                                               1k                      factor
                                                                                             Two, 3.5 dia.                                                     100mV
                                                                                                                                                                                                    10%

                                                       10                                                                                                                                               3%
                                                40 40                                                                                                                                             1%

                                                                       30                                                                                      10                          100

E54-CT3                                                                                                 2.36 dia.
                                                                     30
                                                                                                                                                               1                           RL=10
                                                                                      12 dia.
                                                                                                                            9

                                                                                                                                                               100V

                                                                                                                                                               10

                                                                                                                                                                         1  10 100mA 1          10  100 1,000A

                                                                                                                                                                                           Thru-current (Io) A (r.m.s.)

                                                                                                                               Thru-current (Io) vs. Output Voltage (Eo) (Reference Values)

                                                                                     Two , M3 holes (depth: 4)                 E54-CT3
                                                  15
                                                                                                                               Maximum continuous heater current: 120 A (50/60 Hz) (Maximum
                                                                          30                                                   continuous heater current for an OMRON Digital Temperature Con-
                                                                                                                               troller is 50 A.)
E54-CT3 Accessories
Armature                                                                                                                     Number of windings: 4002

  Approx. 3 dia.                                                                                                               Winding resistance: 80.8

                                                  Connection Example                                                           Output voltage (Eo) V (r.m.s.)  100V Frequency: 50 Hz

                                                                                    Armature                                                                   10                                              Distortion
                                                                                                                                                                            1k                                 factor
                                                                                                                                                                                                               10%
                                                                     Plug                                                                                                   500                               3%
                                                                                                                                                                                                            1%
                                                                                                                                                               1

                                                                                         Lead

                                            18                                                                                                                 100mV                        100
                                                                                                                                                                     10                    50
    Plug                                                                                                                                                            1
                                                                                                                                                                                           RL=10

Approx. 6 dia.                                                                                                                                                 100V         10 100mA    1       10  100 1,000A
                                  (22)                                                                                                                               10
                                                                                                                                                                        1

                                                                                                                                                                                           Thru-current (Io) A (r.m.s.)

14
                                                                                                                                                E5GC

Mounting Adapter                                                                                                                         34.7
Y92F-53 (Two provided.)                                                                                           12

One pair is provided with the Termperature
Controller. Order this Adapter separately if it
becomes lost or damaged.

                                                                                                                  11.8 9.4

Waterproof Packing
Y92S-P12

                                                 The Waterproof Packing is provided with the Temperature Controller.

                                                 Order the Waterproof Packing separately if it becomes lost or damaged.

                                                 The Waterproof Packing can be used to achieve an IP66 degree of protection.

                                                 (Deterioration, shrinking, or hardening of the waterproof packing may occur depending on the operating
                                                 environment. Therefore, periodic replacement is recommended to ensure the level of waterproofing
                                                 specified in IP66. The time for periodic replacement depends on the operating environment.
                                                 Be sure to confirm this point at your site. Consider three years a rough standard.)

                                                 The Waterproof Packing does not need to be attached if a waterproof structure is not required.

Draw-out Jig                                                                                               32.9  1.4
Y92F-55                                                                                                   30.5
                                                                                                                            27.4
Use this Draw-out Jig to remove the interior                                           28.7                            22
body of the Digital Temperature Controller                                                                        20
from the case to perform maintenance
without removing the terminal wiring.

                                                                                    15

                                                                                                                                  23

                                                                                                                                                         15
    Digital Temperature Controller

    E5CC/E5CC-U (48 48 mm)

Large White PV Display That's Easier to Read.
Easy to Use, from Model Selection to
Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.

    The white PV display with a height of 15.2 mm improves visibility.

    High-speed sampling at 50 ms.                                       48 48 mm                            48 48 mm
    Models are available with up to 3 auxiliary outputs, up to 4 event      E5CC                                E5CC-U

    inputs, a transfer output, and a remote SP input to cover a wide Refer to your OMRON website for the most recent information on

    range of applications.                                                applicable safety standards.

    E5CC: Short body with depth of only 60 mm.

    Set up the Controller without wiring the power supply by                        Refer to Safety Precautions on page 104.

    connecting to the computer with a Communications Conversion

    Cable (sold separately). Setup is easy with the CX-Thermo (sold

    separately).

    Easy connections to a PLC with programless communications. Use component communications to link

    Temperature Controllers to each other.

Main I/O Functions

    Sensor Input                                    E5CC/E5CC-U           Dual displays: PV/SV 4-digit displays

      Universal input                        PF (shift) Key
    Thermocouple                           Temperature status display
    Pt                                     Simple programming
    Analog current/voltage                Independent heating and

        Indication Accuracy                  cooling PID control          Control Output 1
                                             Changed parameter display
         Thermocouple input:                Display brightness setting   Relay output
        0.3% of PV                                                       Voltage output (for driving SSR)
         Pt input: 0.2% of PV                                           Linear current output
         Analog input:
        0.2% of FS                                                       Control Output 2

                                                                          

        Sampling Period                                                    None                         None
         50 ms
                                                                           Voltage output

                                                                          (for driving SSR)

    Event Inputs                                                          Auxiliary Outputs

                                                            
    None         None
    2                                                                    3                            None
    4
                                                                                                        1

                                                                                                        2

    Remote SP Input                                                       Transfer Output

                                                          

    None         None                                                   None                         None

    1                                                                    1

    Serial Communications

   

    None         None

    RS-485

    This datasheet is provided as a guideline for selecting products.
    Be sure to refer to the following manuals for application precautions and other information required for operation before attempting
    to use the product.

       E5@C Digital Temperature Controllers User's Manual (Cat. No. H174)
       E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)

16
                                                                                                                                   E5CC/E5CC-U

Model Number Legend and Standard Models

Model Number Legend

Models with Screw Terminals
E5CC-@@ 3 @ 5 M -@@@ (Example: E5CC-RX3A5M-000)

           -- - - - - ---
             A BC DE F

                   A           B          C        D         E   F

Model     Control outputs   No. of    Power    Terminal  Input  Options                                        Meaning
E5CC            1 and 2     auxiliary  supply     type    type
                            outputs    voltage

                                                                                                             48 48 mm

                                                                                    Control output 1                                       Control output 2

       RX                                                                               Relay output                                            None
       QX
*1 *3 CX                                                                             Voltage output                                             None
       QQ                                                                           (for driving SSR)

       CQ                                                                      Linear current output *2                                         None

                                                                                     Voltage output                                         Voltage output
                                                                                    (for driving SSR)                                      (for driving SSR)

                                                                               Linear current output *2                                     Voltage output
                                                                                                                                           (for driving SSR)

                            3                                                                           3 (one common)

                                       A                                                                100 to 240 VAC

                                       D                                                                     24 VAC/DC

                                                5                                       Screw terminals (with cover)

                                                          M                                             Universal input

                                                                          HB alarm and  Communications                             Event   Remote Transfer
                                                                          HS alarm                                                 inputs  SP Input output

                                                                 000      ---                           ---                        ---     ---        ---

                                                                *1 001    1                             ---                        2       ---        ---

                                                                          2

                                                                *1 003 (for 3-phase RS-485                                         ---     ---        ---

                                                                          heaters)

                                                                *3 004    ---                           RS-485                     2       ---        ---

                                                                 005      ---                           ---                        4       ---        ---

                                                                 006      ---                           ---                        2            Provided.

                                                                 007      ---                           ---                        2 Provided. ---

*1. Options with HB and HS alarms (001 and 003) cannot be selected if a linear current output is selected for the control output.

*2. The control output cannot be used as a transfer output.

*3. Option 004 can be selected only when "CX" is selected for the control outputs.

Heating and Cooling Control

Using Heating and Cooling Control

A Control Output Assignment
If there is no control output 2, an auxiliary output is used as the cooling control output.
If there is a control output 2, the two control outputs are used for heating and cooling.
(It does not matter which output is used for heating and which output is used for cooling.)
B Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.

                                                                                                                                                              17
E5CC/E5CC-U

Model Number Legend

Plug-in Models
E5CC-@@ @ @ U M -000 (Example: E5CC-RW0AUM-000)

             A BC DE F

        A                   B        C        D          E            F
                                                                   Options
Model  Control            No. of    Power    Terminal  Input                                            Meaning
E5CC    outputs           auxiliary  supply     type    type          000
        1 and 2           outputs    voltage

                                                                                                         48 48 mm

        RW                                                                         Control output 1                           Control output 2
        QX                                                                       Relay output (SPDT)                                  None
        CX
                                                                                 Voltage output (for driving SSR)                None
                    0
                    1                                                            Linear current output*                          None
                    2
                                                                                                                   None
                                 A
                                 D                                                                                 1

                                              U                                                          2 (one common)
                                                           M
                                                                                                         100 to 240 VAC

                                                                                                         24 VAC/DC

                                                                                                         Plug-in model

                                                                                                         Universal input

                                                                                 HB alarm and HS  Communi-         Event inputs  Remote SP  Transfer out-
                                                                                         alarm      cations                          Input       put

                                                                                 ---              ---                    ---     ---            ---

* The control output can be used as a simple transfer output for the Digital Temperature Controllers manufactured in May 2014 or later.

List of Models

     Control output    No. of auxiliary  HB alarm and              Options  Communications                   Model                             Model
                            outputs         HS alarm                                              Power supply voltage              Power supply voltage
    Relay output                                              No. of event
                                                                  inputs                              100 to 240 VAC                       24 VAC/DC
    Voltage output                                                                          E5CC-RW0AUM-000                   E5CC-RW0DUM-000
    (for driving SSR)  ---                                                                  E5CC-RW1AUM-000                   E5CC-RW1DUM-000
                                                                                            E5CC-RW2AUM-000                   E5CC-RW2DUM-000
    Linear current     1                 ---                  ---           ---             E5CC-QX0AUM-000                   E5CC-QX0DUM-000
    output                                                                                  E5CC-QX1AUM-000                   E5CC-QX1DUM-000
                       2                                                                    E5CC-QX2AUM-000                   E5CC-QX2DUM-000
                                                                                            E5CC-CX0AUM-000                   E5CC-CX0DUM-000
                       ---                                                                  E5CC-CX1AUM-000                   E5CC-CX1DUM-000
                                                                                            E5CC-CX2AUM-000                   E5CC-CX2DUM-000
                       1                 ---                  ---           ---

                       2

                       ---

                       1                 ---                  ---           ---

                       2

Heating and Cooling Control

Using Heating and Cooling Control

A Control Output Assignment
An auxiliary output is used as the cooling control output.
B Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.

18
                                                                                         E5CC/E5CC-U

Optional Products (Order Separately)                                  Front Covers         Model
                                                                                         Y92A-48H
USB-Serial Conversion Cable                                                       Type   Y92A-48D
                                                                       Hard Front Cover
                      Model                                            Soft Front Cover
                   E58-CIFQ2

Terminal Covers (for E5CC)                                            CX-Thermo Support Software

                      Model                                                                 Model
                   E53-COV17                                                           EST2-2C-MV4
              E53-COV23 (3pcs)
                                                                      Note: CX-Thermo version 4.5 or higher is required for the E5CC.
Note: The Terminal Covers E53-COV23 are provided only with E5CC               CX-Thermo version 4.61 or higher is required for the E5CC-U.
        Controllers. The E53-COV10 cannot be used.                            For the system requirements for the CX-Thermo, refer to
        Refer to page 28 for the mounted dimensions.                          information on the EST2-2C-MV4 on the OMRON website
                                                                              (www.ia.omron.com).
Waterproof Packing

                      Model
                     Y92S-P8

Note: The Waterproof Packing is provided only with E5CC
        Controllers.
        The E5CC-U cannot be waterproofed even if the Waterproof
        Packing is attached.

Current Transformers (CTs)

Hole diameter   Model
    5.8 mm     E54-CT1
    12.0 mm    E54-CT3

Adapter

                      Model
                     Y92F-45
Note: Use this Adapter when the panel has already been prepared for
        an E5B@ Controller.

Waterproof Cover

                      Model
                    Y92A-48N

Mounting Adapter

                      Model
                     Y92F-49
Note: This Mounting Adapter is provided with the Digital Temperature
        Controller.

DIN Track Mounting Adapter

                      Model
                     Y92F-52

Sockets (for E5CC-U)                                Model
                                                  P2CF-11
                            Type                 P2CF-11-E
Front-connecting Socket                          P3GA-11
Front-connecting Socket with Finger Protection
Back-connecting Socket                          Y92A-48G
Terminal Cover for Back-connecting socket
with Finger Protection

                                                                                                   19
E5CC/E5CC-U

Specifications

Ratings

    Power supply voltage               A in model number: 100 to 240 VAC, 50/60 Hz
                                       D in model number: 24 VAC, 50/60 Hz; 24 VDC

    Operating voltage range            85% to 110% of rated supply voltage

    Power consumption                  Models with option selection of 000: 5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at 24 VAC or
                                                                                       1.6 W max. at 24 VDC

                                       All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC

    Sensor input                       Temperature input
    Input impedance                         Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
                                            Platinum resistance thermometer: Pt100 or JPt100
                                            Infrared temperature sensor (ES1B): 10 to 70C, 60 to 120C, 115 to 165C, or 140 to 260C

                                       Analog input
                                             Current input: 4 to 20 mA or 0 to 20 mA
                                             Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V,or 0 to 50 mV (The 0 to 50 mV range applies to the
                                                                 E5CC-U only for those manufactured in May 2014 or later.)

                                       Current input: 150  max., Voltage input: 1 M min.
                                       (Use a 1:1 connection when connecting the ES2-HB/THB.)

    Control method                     ON/OFF control or 2-PID control (with auto-tuning)

    Control    Relay output            E5CC: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum ap-
    output                                           plicable load: 5 V, 10 mA (reference value)
               Voltage output
    Auxiliary  (for driving SSR)       E5CC-U: SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applica-
    output     Linear current output                 ble load: 5 V, 10 mA (reference value)
               Number of outputs
                                       Output voltage: 12 VDC 20% (PNP), max. load current: 21 mA, with short-circuit protection circuit
               Output specifications
                                       4 to 20 mA DC/0 to 20 mA DC, load: 500  max., resolution: approx. 10,000
                                       E5CC: 3
                                       E5CC-U: 1 or 2 (depends on model)
                                       SPST-NO relay outputs, 250 VAC, Models with 1 or 2 outputs: 3 A (resistive load), or Models with 3
                                       outputs: 2 A (resistive load), Electrical life: 100,000 operations, Minimum applicable load: 10 mA at
                                       5 V (reference value)

    Event      Number of inputs        2 or 4 (depends on model)
    input*                             Contact input: ON: 1 k max., OFF: 100 k min.
               External contact input  Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
               specifications          Current flow: Approx. 7 mA per contact

    Transfer   Number of outputs       1 (only on models with a transfer output)
    output*    Output specifications
                                       Current output: 4 to 20 mA DC, load: 500  max., resolution: approx. 10,000
    Setting method                     Linear voltage output: 1 to 5 VDC, load: 1 k min., resolution: Approx. 10,000

    Remote SP input*                   Digital setting using front panel keys

                                       Current input: 4 to 20 mA DC or 0 to 20 mA DC (input impedance: 150  max.)
                                       Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V (input impedance: 1 M min.)

    Indication method                  11-segment digital display and individual indicators
                                       Character height: PV: 15.2 mm, SV: 7.1 mm

    Multi SP*                          Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations,
                                       or serial communications.

    Bank switching                     None

    Other functions                    Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater
                                       burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital
    Ambient operating temperature      filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root,
    Ambient operating humidity         MV change rate limit, logic operations, temperature status display, simple programming, moving
    Storage temperature                average of input value, and display brightness setting

                                       -10 to 55C (with no condensation or icing), For 3-year warranty: -10 to 50C with standard mounting
                                       (with no condensation or icing)

                                       25% to 85%

                                       -25 to 65C (with no condensation or icing)

    Altitude                           2,000 m max.

    Recommended fuse                   T2A, 250 VAC, time-lag, low-breaking capacity

    Installation environment           Installation Category II, Pollution Degree 2 (IEC 61010-1 compliant)

* There are no optional functions for the E5CC-U. Refer to Model Number Legend and List of Models on page 18.

20
                                                                                                                                                                                        E5CC/E5CC-U

Input Ranges

Thermocouple/Platinum Resistance Thermometer (Universal inputs)

Sensor                                    Platinum resistance                                                             Thermocouple                                                       Infrared temperature
   type                                         thermometer                                                                                                                                            sensor

Sensor                                         Pt100          JPt100             K                J               T       EL          U                   N     R     S     B     W    PLII  10 to 60 to 115 to 140 to
specifica-                                                                                                                                                                                    70C 120C 165C 260C
                                                                             1300             850             400 400.0                                   1300  1700  1700  1800  2300
    tion           Temperature range (C)                                                              400.0  -200 -199.9                                                               1300
                                                                                       500.0                                                              -200    0     0   100     0
             2300                          850                                                -100 -20.0       9 10                  850
             1800                                                                      -20.0                                                              15    16    17    18    19
             1700                               500.0          500.0         -200              78                          600
             1600                                                                                                                              400 400.0
             1500                                                             56
             1400                                       100.0         100.0                                                                                                                                                 260
             1300                                                                                                                                                                                      120 165
             1200                                                                                                                                                                             90
             1100
             1000                                       0.0           0.0                                                                                                               0     0  0  0  0

              900                                                                                                                -100
              800
              700                          -200 -199.9         199.9                                                       -200        -200 -199.9
              600
              500                          01234                                                                           11 12 13 14                                                  20 21 22 23 24
              400
              300
              200
              100

                  0
             -100
             -200

Set value

                                           Shaded settings are the default settings.

The applicable standards for the input types are as follows:                                      JPt100: JIS C 1604-1989, JIS C 1606-1989
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 60584-1                                              Pt100: JIS C 1604-1997, IEC 60751
L: Fe-CuNi, DIN 43710-1985                                                                        PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)
U: Cu-CuNi, DIN 43710-1985
W: W5Re/W26Re, ASTM E988-1990

Analog input

                   Input type                                  Current                                            Voltage

Input                                           4 to 20 mA 0 to 20 mA 1 to 5 V                                0 to 5 V 0 to 10 V 0 to 50 mV*
specification

Setting range                                   Usable in the following ranges by scaling:
                                                -1999 to 9999, -199.9 to 999.9,
                                                -19.99 to 99.99 or -1.999 to 9.999

Set value                                               25              26                    27              28                 29                       30

* The range applies to the E5CC-U only for those manufactured in May 2014 or later.

                                                                                                                                                                                                                                 21
E5CC/E5CC-U

Alarm Types

Each alarm can be independently set to one of the following 19 alarm types. The default is 2: Upper limit. (see note.)
Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed.

        To use alarm 1, set the output assignment to alarm 1.

     Set                                                     Alarm output operation
    value
                   Alarm type              When alarm value X When alarm value X                                      Description of function

                                                is positive                        is negative

    0 Alarm function OFF                                              Output OFF                          No alarm

    1          Upper- and lower-limit *1   ON                LH                                           Set the upward deviation in the set point for the alarm upper
                                           OFF                                                            limit (H) and the lower deviation in the set point for the alarm
                                                             SP       PV *2                               lower limit (L). The alarm is ON when the PV is outside this
                                                                                                          deviation range.

        2      Upper-limit                 ON                      X          ON   X                  Set the upward deviation in the set point by setting the alarm
    (default)                              OFF                                                  PV value (X). The alarm is ON when the PV is higher than the
                                                             SP       PV      OFF  SP                     SP by the deviation or more.

                                           ON                X                ON         X                Set the downward deviation in the set point by setting the

    3 Lower-limit                          OFF                        PV      OFF               PV alarm value (X). The alarm is ON when the PV is lower than
                                                               SP
                                                                                   SP                     the SP by the deviation or more.

    4          Upper- and lower-limit      ON                LH                                           Set the upward deviation in the set point for the alarm upper
               range *1                    OFF                                                            limit (H) and the lower deviation in the set point for the alarm
                                                             SP       PV *3                               lower limit (L). The alarm is ON when the PV is inside this de-
                                                                                                          viation range.

    5          Upper- and lower-limit      ON                LH       PV *4                               A standby sequence is added to the upper- and lower-limit
                                                              SP                                          alarm (1). *6
               with standby sequence *1 *5 OFF

    6          Upper-limit with standby    ON                      X          ON   X            PV A standby sequence is added to the upper-limit alarm (2). *6
               sequence                    OFF
                                                             SP       PV      OFF  SP

    7          Lower-limit with standby    ON                X                ON       X
               sequence                    OFF                SP
                                                                      PV      OFF            PV A standby sequence is added to the lower-limit alarm (3). *6

                                                                                   SP

    8          Absolute-value upper-lim- ON                     X             ON      X                   The alarm will turn ON if the process value is larger than the

               it                          OFF                        PV      OFF           0 PV alarm value (X) regardless of the set point.
                                                          0

    9          Absolute-value lower-limit  ON                   X             ON      X                   The alarm will turn ON if the process value is smaller than the
                                           OFF
                                                0                     PV      OFF           0 PV alarm value (X) regardless of the set point.

    10         Absolute-value upper-lim- ON                     X             ON      X                   A standby sequence is added to the absolute-value upper-

               it with standby sequence OFF 0                         PV      OFF           0 PV limit alarm (8). *6

    11         Absolute-value lower-limit ON                    X             ON      X                   A standby sequence is added to the absolute-value lower-

               with standby sequence       OFF                        PV      OFF           0 PV limit alarm (9). *6
                                                          0

    12 LBA (alarm 1 type only)                                             -                              *7

    13 PV change rate alarm                                                -                              *8

    14         SP absolute-value           ON        X                        ON      X                   This alarm type turns ON the alarm when the set point (SP)
               upper-limit alarm           OFF  0
                                                                      SP      OFF           0 SP is higher than the alarm value (X).

    15         SP absolute-value           ON                   X             ON      X                   This alarm type turns ON the alarm when the set point (SP)
               lower-limit alarm                                              OFF                     SP  is lower than the alarm value (X).
                                           OFF  0                     SP
                                                                                           0

                                           Standard Control                   Standard Control

                                           ON                   X             ON      X

                                           OFF                        MV      OFF               MV
                                                          0
               MV absolute-value                                                            0             This alarm type turns ON the alarm when the manipulated
               upper-limit alarm *9
    16                                     Heating/Cooling                    Heating/Cooling             variable (MV) is higher than the alarm value (X).

                                           Control (Heating MV) Control (Heating MV)

                                           ON                   X

                                           OFF                        MV Always ON
                                                          0

                                           Standard Control Standard Control

                                           ON                   X             ON      X

                                           OFF  0                     MV      OFF           0   MV

    17         MV absolute-value           Heating/Cooling                    Heating/Cooling             This alarm type turns ON the alarm when the manipulated
               lower-limit alarm *9        Control (Cooling MV)               Control (Cooling MV)        variable (MV) is lower than the alarm value (X).

                                           ON                   X

                                           OFF                        MV Always ON
                                                          0

               RSP absolute-value          ON        X                        ON      X                   This alarm type turns ON the alarm when the remote SP
               upper-limit alarm *10       OFF  0                             OFF
    18                                                                RSP                   0 RSP (RSP) is higher than the alarm value (X).

               RSP absolute-value          ON        X                        ON      X                   This alarm type turns ON the alarm when the remote SP
               lower-limit alarm *10       OFF  0                             OFF
    19                                                                RSP                   0 RSP (RSP) is lower than the alarm value (X).

22
                                                                            E5CC/E5CC-U

*1 With set values 1, 4 and 5, the upper and lower limit values can be set  *4 Set value: 5, Upper- and lower-limit with standby sequence
      independently for each alarm type, and are expressed as "L" and "H."
                                                                                    For Upper- and Lower-Limit Alarm Described Above *2
*2 Set value: 1, Upper- and lower-limit alarm
                                                                                  Case 1 and 2
Case 1          Case 2          Case 3 (Always ON)     H<0, L<0                     Always OFF when the upper-limit and lower-limit hysteresis overlaps.
                                     H SP L
       L H SP     SP L H                               H<0, L>0                   Case 3: Always OFF
    H<0, L>0        H>0, L<0       H L SP               |H|  |L|
     |H| < |L|       |H| > |L|             SP H L      H>0, L<0             *5. Set value: 5, Upper- and lower-limit with standby sequence
                                                        |H|  |L|                    Always OFF when the upper-limit and lower-limit hysteresis overlaps.

*3 Set value: 4, Upper- and lower-limit range                               *6 Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.
                                                                                  H174) for information on the operation of the standby sequence.
Case 1          Case 2          Case 3 (Always OFF)    H<0, L<0
                                       H SP L                               *7 Refer to the E5@C Digital Temperature Controllers User's Manual (Cat.
       L H SP     SP L H                               H<0, L>0                   No.H174) for information on the loop burnout alarm (LBA).
    H<0, L>0        H>0, L<0        H L SP              |H|  |L|
     |H| < |L|       |H| > |L|                                              *8 Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.
                                                                                  H174) for information on the PV change rate alarm.
                                               SP H L  H>0, L<0
                                                        |H|  |L|            *9 When heating/cooling control is performed, the MV absolute upper limit
                                                                                  alarm functions only for the heating operation and the MV absolute lower
                                                                                  limit alarm functions only for the cooling operation.

                                                                            *10 This value is displayed only when a remote SP input is used. It functions in
                                                                                  both Local SP Mode and Remote SP Mode.
                                                                                  Remote SP input is supported only for the E5CC.

                                                                            23
E5CC/E5CC-U

Characteristics

                                           E5CC

                                           Thermocouple:  (0.3% of indication value or 1C, whichever is greater) 1 digit max. *1

                                           Platinum resistance thermometer: (0.2% of indication value or 0.8C, whichever is greater) 1 digit max.

    Indication accuracy                    Analog input:  0.2% FS 1 digit max.
    (at the ambient temperature of 23C)
                                           CT input:      5% FS 1 digit max.

                                           E5CC-U

                                           Thermocouple:  (1% of indication value or 2C, whichever is greater) 1 digit max. *1

                                           Platinum resistance thermometer: (0.2% of indication value or 0.8C, whichever is greater) 1 digit max.

                                           Analog input:  0.2% FS 1 digit max.

    Transfer output accuracy               0.3% FS max.
    Remote SP Input Type
    Influence of temperature *2            0.2% FS 1 digit max.

    Influence of voltage *2                Thermocouple input (R, S, B, W, PL II): (1% of indication value or 10C, whichever is greater) 1 digit
                                           max.
                                           Other thermocouple input: (1% of indication value or 4C, whichever is greater) 1 digit max. *3
                                           Platinum resistance thermometer: (1% of indication value or 2C, whichever is greater) 1 digit max.
                                           Analog input: 1%FS 1 digit max.
                                           CT input: 5% FS 1 digit max.
                                           Remote SP input: 1% FS 1 digit max.

    Input sampling period                  50 ms
    Hysteresis
                                           Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                           Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

    Proportional band (P)                  Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                           Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

    Integral time (I)                      0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4
    Derivative time (D)
                                           0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

    Proportional band (P) for cooling      Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                           Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

    Integral time (I) for cooling          0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4
    Derivative time (D) for cooling
    Control period                         0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4
    Manual reset value
    Alarm setting range                    0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)

                                           0.0 to 100.0% (in units of 0.1%)

                                           -1999 to 9999 (decimal point position depends on input type)

    Influence of signal source resistance  Thermocouple: 0.1C/ max. (100 max.)
                                           Platinum resistance thermometer: 0.1C/ max. (10  max.)

    Insulation resistance                  20 M min. (at 500 VDC)

    Dielectric strength                    3,000 VAC, 50/60 Hz for 1 min between terminals of different charge

    Vibration  Malfunction                 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
               Resistance
                                           10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions

    Shock      Malfunction                 100 m/s2, 3 times each in X, Y, and Z directions
               Resistance
                                           300 m/s2, 3 times each in X, Y, and Z directions

    Weight                                 E5CC: Controller: Approx. 120 g, Adapter: Approx. 10 g
                                           E5CC-U: Controller: Approx. 100 g, Adapter: Approx. 10 g

    Degree of protection                   E5CC: Front panel: IP66, Rear case: IP20, Terminals: IP00
    Memory protection                      E5CC-U: Front panel: IP50, Rear case: IP20, Terminals: IP00
    Setup Tool
                                           Non-volatile memory (number of writes: 1,000,000 times)

                                           E5CC: CX-Thermo version 4.5 or higher
                                           E5CC-U: CX-Thermo version 4.61 or higher

    Setup Tool port                        E5CC/E5CC-U top panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect to a USB
                       Approved standards                                     port on the computer. *5

    Standards Conformed standards          UL 61010-1*6, KOSHA certified (some models) *7, Korean Radio Waves Act (Act 10564)

                                           EN 61010-1 (IEC 61010-1): Pollution Degree 2, overvoltage category II, Lloyd's standards *8

    EMC                                    EMI:                                                     EN61326
                                           Radiated Interference Electromagnetic Field Strength:    EN 55011 Group 1, class A
                                           Noise Terminal Voltage:                                  EN 55011 Group 1, class A
                                           EMS:                                                     EN 61326
                                           ESD Immunity:                                            EN 61000-4-2
                                           Electromagnetic Field Immunity:                          EN 61000-4-3
                                           Burst Noise Immunity:                                    EN 61000-4-4
                                           Conducted Disturbance Immunity:                          EN 61000-4-6
                                           Surge Immunity:                                          EN 61000-4-5
                                           Voltage Dip/Interrupting Immunity:                       EN 61000-4-11

*1 The indication accuracy of K thermocouples in the -200 to 1,300C range, T and N thermocouples at a temperature of -100C max., and U and
     L thermocouples at any temperatures is 2C 1 digit max. The indication accuracy of the B thermocouple at a temperature of 400C max. is
     not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800C is 3C max. The indication accuracy of the R and
     S thermocouples at a temperature of 200C max. is 3C 1 digit max. The indication accuracy of W thermocouples is (0.3% of PV or 3C,
     whichever is greater) 1 digit max. The indication accuracy of PL II thermocouples is (0.3% of PV or 2C, whichever is greater) 1 digit max.

*2 Ambient temperature: -10C to 23C to 55C, Voltage range: -15% to 10% of rated voltage
*3 K thermocouple at -100C max.: 10C max.
*4 The unit is determined by the setting of the Integral/Derivative Time Unit parameter.
*5 External communications (RS-485) and USB-serial conversion cable communications can be used at the same time.
*6 The E5CC-U plug-in model is certified for UL listing only when used together with the OMRON P2CF-11 or P2CF-11-E Socket. The P3GA-11

     is not certified for UL listing.
*7 Access the following website for information on certified models. http://www.ia.omron.com/support/models/index.html
*8 Refer to information on maritime standards in Shipping Standards on page 106 for compliance with Lloyd's Standards.

24
                                                                                                                                        E5CC/E5CC-U

USB-Serial Conversion Cable                                                                                                    When Digital Temperature Controllers are con-
                                                                                                                               nected, set points and RUN/STOP commands
Applicable OS          Windows XP/Vista/7/8                                                                                    can be sent from the Digital Temperature Control-
                                                                                                                               ler that is set as the master to the Digital Temper-
Applicable software    CX-Thermo version 4.5 or higher (Version 4.61 or     Component                                          ature Controllers that are set as slaves.
                       higher is required for the E5CC-U.)                  Communications*1                                   Slope and offsets can be set for the set point.
                                                                                                                               Number of connected Digital Temperature Con-
Applicable models      E5@C-T Series, E5@C Series, and E5CB Series                                                             trollers: 32 max. (including master)

USB interface standard Conforms to USB Specification 2.0.

DTE speed              38400 bps                                                                                               When Digital Temperature Controllers are con-
                                                                                                                               nected, the parameters can be copied from the
Connector              Computer: USB (type A plug)                          Copying*2                                          Digital Temperature Controller that is set as the
specifications         Digital Temperature Controller:                                                                         master to the Digital Temperature Controllers that
                       Special serial connector                                                                                are set as slaves.

Power supply           Bus power (Supplied from USB host controller.)*      MELSEC is a registered trademark of Mitsubishi Electric Corporation.

Power supply voltage 5 VDC                                                  KEYENCE is a registered trademark of Keyence Corporation.

Current consumption    450 mA max.                                          *1 A Temperature Controller with version 1.1 or higher is required.
Output voltage                                                                   A Temperature Controller with version 2.1 or higher is required for
                       4.70.2 VDC                                               the FX Series or the KV Series.
                       (Supplied from USB-Serial Conversion Cable to
                       the Digital Temperature Controller.)                 *2 Both the programless communications and the component
                                                                                 communications support the copying.
                       250 mA max.
Output current         (Supplied from USB-Serial Conversion Cable to        Current Transformer (Order Separately)
                       the Digital Temperature Controller.)                 Ratings

Ambient operating      0 to 55C (with no condensation or icing)
temperature

Ambient operating      10% to 80%                                           Dielectric strength                                1,000 VAC for 1 min
humidity                                                                    Vibration resistance                               50 Hz, 98 m/s2

Storage temperature -20 to 60C (with no condensation or icing)             Weight                                             E54-CT1: Approx. 11.5 g,
                                                                                                                               E54-CT3: Approx. 50 g
Storage humidity       10% to 80%                                           Accessories
                                                                            (E54-CT3 only)                                     Armatures (2)
Altitude               2,000 m max.                                                                                            Plugs (2)

Weight                 Approx. 120 g

Windows is a registered trademark of Microsoft Corporation in the           Heater Burnout Alarms and SSR Failure
                                                                            Alarms
United States and or other countries.
                                                                            CT input (for heater                               Models with detection for single-phase
* Use a high-power port for the USB port.                                   current detection)                                 heaters: One input
Note: A driver must be installed on the computer. Refer to the                                                                 Models with detection for singlephase or
                                                                            Maximum heater                                     three-phase heaters: Two inputs
        Instruction Manual included with the Cable for the installation     current
        procedure.                                                          Input current                                      50 A AC
                                                                            indication accuracy
Communications Specifications                                               Heater burnout                                     5% FS 1 digit max.
                                                                            alarm setting range
Transmission line      RS-485: Multidrop                                    *1                                                 0.1 to 49.9 A (in units of 0.1 A)
connection method      RS-485 (two-wire, half duplex)                       SSR failure alarm                                  Minimum detection ON time: 100 ms *3
                       Start-stop synchronization                           setting range *2
Communications         CompoWay/F, or Modbus                                                                                   0.1 to 49.9 A (in units of 0.1 A)
                       9600, 19200, 38400, or 57600 bps                                                                        Minimum detection OFF time: 100 ms *4
Synchronization
method

Protocol

Baud rate*

Transmission code      ASCII                                                *1 For heater burnout alarms, the heater current will be measured
Data bit length*
Stop bit length*       7 or 8 bits                                               when the control output is ON, and the output will turn ON if the

Error detection        1 or 2 bits                                               heater current is lower than the set value (i.e., heater burnout

                       Vertical parity (none, even, odd)                         detection current value).
                       Block check character (BCC) with
                       CompoWay/F or CRC-16 Modbus                          *2 For SSR failure alarms, the heater current will be measured when
                                                                                 the control output is OFF, and the output will turn ON if the heater
Flow control           None                                                      current is higher than the set value (i.e., SSR failure detection
Interface              RS-485                                                    current value).
Retry function         None
Communications buffer  217 bytes                                            *3 The value is 30 ms for a control period of 0.1 s or 0.2 s.
Communications         0 to 99 ms                                           *4 The value is 35 ms for a control period of 0.1 s or 0.2 s.
response wait time     Default: 20 ms

* The baud rate, data bit length, stop bit length, and vertical parity can  Electrical Life Expectancy Curve for
  be individually set using the Communications Setting Level.               Relays (Reference Values)

Communications Functions                                                    Life ( 104 operations)  500
                                                                                                     300
                       You can use the memory in the PLC to read and
                       write E5@C parameters, start and stop operation,                              100
                       etc. The E5@C automatically performs communi-
                       cations with PLCs. No communications program-                                  50
                       ming is required.                                                              30
                       Number of connected Digital Temperature Con-
Programless            trollers: 32 max. (Up to 16 for the FX Series)                                10
communications*1       Applicable PLCs

                          OMRON PLCs                                                                 5       E5CC
                              CS Series, CJ Series, or
                              CP Series                                                              3       250 VAC, 30 VDC
                                                                                                             (resistive load)
                          Mitsubishi Electric PLCs
                              MELSEC Q Series, L Series, or FX Series                                        cos = 1
                              (compatible with the FX2 or FX3 (excluding
                              the FX1S))                                                             1

                          KEYENCE PLCs                                                                    0  1        2        3  4  5  6
                              KEYENCE KV Series

                                                                                                                                  Switching current (A)

                                                                                                                                                                                   25
E5CC/E5CC-U

External Connections

E5CC                                     Control output 2           Auxiliary outputs 1, 2, 3     E5CC-@@ 3 @ 5 M - @@@

        Control output 1                 Voltage output            Relay outputs                               (1) (2) (3) (4) (5) (6)
                                         (for driving SSR)         Models with 3 auxiliary                                       
      Relay output                       12 VDC, 21 mA             outputs: 250 VAC, 2 A
      250 VAC, 3A                                                  (resistive load)                                       Terminal type
      (resistive load)
      Voltage output                                                                                  The E5CC is set for a K-type thermocouple (input type = 5) by
      (for driving SSR)                                                                               default. An input error (s.err) will occur if the input type setting does
      12 VDC, 21 mA                                                                                   not agree with the temperature sensor. Check the input type.
      Linear current output
      0 to 20 mA DC
      4 to 20 mA DC
      Load: 500  max.

    (1) Control outputs 1, 2                                          QQ

          RX              QX                       CX                                          CQ

    Models with   Models with 1                Models with Models with 2                    Models with 2 Outputs: Linear Current     (2) Auxiliary Outputs
    1 Relay       Voltage Output                                   Voltage Outputs          Output and Voltage (for Driving SSR)               Auxiliary outputs 1, 2, 3
    Output        (for Driving SSR)            1 Linear
                                               Current Output (for Driving SSR)

       1      OUT1 1          +          OUT1  1          +  OUT1  1           OUT1            1       OUT1                                           7     Auxiliary output 3
       2      R2              -          Q     2          -  C     2         +Q                      +C
                                               3                                                                                                      8 Auxiliary output 2
                                                                             -  Q              2     -   Q                                            9
       3          3                                                3         +  OUT2           3     +   OUT2                                                Auxiliary output 1

                                                                                                                                                      10   

                                                                                            1        13            7

                                                                                            2        14            8

(5) Sensor (Temperature/Analog) Input                                                       3        15            9                  (3) Input Power Supply
                                                                                                                                       100 to 240 VAC 24 VAC/DC
          TC          Pt            I          V                                            4        16            10
           4      A4
       -5          B           +4               4                                           5        17            11
                             mA 5          -5
       +6              5                 V6                                                 6        18            12                             11               11
                   B            -          +
                                    6                                                                                                             12               12
                       6

                                                                                                                                                              (no polarity)

    (6) Options                          003                 004                                  005                  006                                    007
        001                              Communications      Communications                       Event Inputs         Event Inputs
        Event Inputs 1                   (RS-485), CT1,      (RS-485), and                        1 to 4               1 and 2, and                           Event Inputs
        and 2, and CT1                   and CT2             Event Inputs 3 and 4                                      Transfer Output                        1 and 2, and
                                                                                                                                                              Remote SP Input
    -                                           B(+)                   B(+)
              13                                                                                  -            13                  -              13          -                  13
                                                      13                     13
       +      14                                                                                     +         14                     +           14             +               14
    + EV1     15                            RS-485                 RS-485                         + EV1        15                  + EV1          15          + EV1              15
     EV2                                                                                           EV2                              EV2                        EV2
                                                      14                     14

                                                A(-)                   A(-)

                                                      15                     15

              16                                      16           -            16                -            16                                 16       +  +       +          16
                                                                                                                                                      +V              mA
    CT1                                    CT1                        +         17                   +         17                                 17  I            V             17
                                                                   + EV3                              EV3
              17                                COM 17                                            +                                                        -

              18                           CT2                     EV4 18                            EV4 18                                       18          -                  18

                                                      18

E5CC-U

                              The E5CC-U is set for a K-type thermocouple (input type =                    E5CC-       UM-000
                              5) by default. An input error (s.err) will occur if the input
                              type setting does not agree with the temperature sensor.                         Control output 1
                              Check the input type.
                                                                                                                  Auxiliary outputs 1, 2

                                                                                                               Relay output
                                                                                                               250 VAC, 3 A (resistive load)

                                                                          Control output 1

                                                        I                       Pt                             Auxiliary output 1
                                                                                   A                                         Auxiliary output 2:
                                                       +                                                                     Control output (cooling side)
                                                                 V        TC
                                                   mA                                                          Input power supply
                                                                -         -         B                                    100 to 240 VAC
                                                       -                                                                24 VAC/DC (no polarity)
                                                             V
                                                                          +         B
                                                                +

                                                          Sensor (temperature/analog) input

        Control output 1                       Control output 1:                                    CX                                RW
                                                              QX                                                                   Models with 1
    Voltage output (for driving SSR)                                                           Models with 1                       Relay Output
    12 VDC, 21 mA                                   Models with 1                              Linear Current
                                                    Voltage Output                             Output                  Output 1
    Linear current output                           (for Driving SSR)                                                      R
    4 to 20 mA DC                                                                            -
    0 to 20 mA DC                                       -
    Load: 500  max.                                                                 Output 1
                                                Output 1                                C
    Relay output (three terminals used)             Q
    SPDT, 250 VAC, 3 A                                                                      +
    (resistive load)                                    +

Note: 1. The application of the terminals depends on the model.
        2. Do not wire the terminals that are shown with a gray background.
        3. When complying with EMC standards, the cable that connects the sensor must be 30 m or less.
            If the cable length exceeds 30 m, compliance with EMC standards will not be possible.
        4. Connect M3 crimped terminals.
            Connect M3.5 crimped terminals for the E5CC-U.

26
                                                                                                                               E5CC/E5CC-U

Isolation/Insulation Block Diagrams

E5CC

Models with 3 Auxiliary Outputs

Power   Sensor input, CT inputs, and remote SP input
supply         Communications and event inputs
                Voltage output (for driving SSR),

           linear current output, and transfer output

                             Relay output
                      Auxiliary outputs 1, 2, 3

                             : Reinforced insulation
                             : Functional isolation

     Note: Auxiliary outputs 1 to 3 are not insulated.

E5CC-U

Models with 2 Auxiliary Outputs

Power                                Sensor input
supply  Voltage output (for driving SSR) and linear current output

                                     Relay output
                             Auxiliary outputs 1 and 2

        : Reinforced insulation
        : Functional isolation

Nomenclature

E5CC                                 Front panel
E5CC-U
                   Temperature unit                                                                          Top View of E5CC  Top View of E5CC-U
              Operation indicators
                                                                              No. 1 display
                                                                            PV or specified parameter

                                                                               No. 2 display
                                                                            SP or specified parameter value

                                                                            Use the U D Keys to set the
                                                                            parameter.

                                                                                                                              Top-panel Setup Tool port

        Press O Key once to go to Adjustment Level.                         Use S Key to change the digit (default setting).
        Press O Key for at least 3 seconds to go to Initial Setting Level.

                                                                            Use the M Key to change to another parameter.

                                                                                                                                                         27
E5CC/E5CC-U                                                                                                                                                         (Unit: mm)
Dimensions
                                                                                   4          73.1
Controllers                                                                              1  60

E5CC                                                                                                                                                       48 48
                                                                                                              44.8 44.8 48.8 58
                                                                 48 48

                 Waterproof Packing                                                         Mounting Adapter  Terminal Cover
                 (Accessory)                                                                (Accessory)       (E53-COV17)
                                                                                                              (Sold separately)

        The Setup Tool port is on the top of the Temperature Controller.
        It is used to connect the Temperature Controller to the computer to use the Setup Tool.
        The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection.
        Refer to the instructions that are provided with the USB-Serial Conversion Cable for the connection procedure.

        Note: Do not leave the USB-Serial Conversion Cable connected when you use the Temperature Controller.

                                                                                   Panel Cutout

        Mounted Separately                                                                           Group Mounted

                                                                                                    (48 number of units - 2.5)+10.0

                                                                                                                    45+00.6             Recommended panel thickness is 1 to 5 mm.

        60 min.                                                                                                                         Group mounting is not possible in the vertical direction. (Maintain
                                                                                                                                          the specified mounting space between Controllers.)
                                                                                   45+00.6
                                                                                                                                        To mount the Controller so that it is waterproof, insert the
                                                                          45+00.6                                                         waterproof packing onto the Controller.

                                                                                                                                        When two or more Controllers are mounted, make sure that the
                                                                                                                                          surrounding temperature does not exceed the allowable operating
                                                                                                                                          temperature specified in the specifications.

                                                                                                                                        Use a control panel thickness of 1 to 3 mm if the Y92A-48N and a
                                                                                                                                          USB-Serial Conversion Cable are used together.

E5CC-U                                                                                         76.8
                                                                                            58.6
                                        4                                                                     14.2
                 48 48
                                                                                                                                       48 48

                                                                                                              58

                                                    Mounting Adapter
                                                    (Accessory)

        The Setup Tool port is on the top of the Temperature Controller.
        It is used to connect the Temperature Controller to the computer to use the Setup Tool.
        The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection.
        Refer to the instructions that are provided with the USB-Serial Conversion Cable for the connection procedure.

        Note: Do not leave the USB-Serial Conversion Cable connected when you use the Temperature Controller.

                                                                                   Panel Cutout

        Mounted Separately                                                                           Group Mounted

                                                                                                     (48 number of units - 2.5)+10.0

                                                                                                                    45+00.6             Recommended panel thickness is 1 to 5 mm.

        60 min.                                                                                                                         Group mounting is not possible in the vertical direction. (Maintain
                                                                                                                                          the specified mounting space between Controllers.)
                                                                                   45+00.6
                                                                                                                                        When two or more Controllers are mounted, make sure that the
                                                                                                                                          surrounding temperature does not exceed the allowable operating
                                                                                                                                          temperature specified in the specifications.

                                                                                                                                        Use a control panel thickness of 1 to 3 mm if the Y92A-48N and a
                                                                                                                                          USB-Serial Conversion Cable are used together.

                                                                          45+00.6

28
                                                                                                                                                                                   E5CC/E5CC-U

Accessories (Order Separately)                                                                                                       (2110)                                        1510
                                                                                                                                                                    263
USB-Serial Conversion Cable
E58-CIFQ2                                                                                                         LED (RD)

                                                                                                      250

                                        USB connector                                                                                            LED (PWR)                              Serial connector
                                        (type A plug)                                                                                             LED (SD)
                                                                                                                                                                                   Terminal Cover
Terminal Covers                        48                                                                         Terminal Covers                                                 (E53-COV23)
                                                                                                                  E53-COV23 (Three Covers provided.)
E53-COV17
                                                                                                                                                                            2 3.8
                           48.8
                                                                                                                                                                10

                           22                                                                                     44.8

                                                             9.1

Terminal Cover (for the P3GA-11 Back-connecting Socket)
Y92A-48G

                                                              Twelve, 6.4-dia.

                  34       UP Y92A-48G  47.747.7                                                          4848

                                 PC

                                            16.5
                                                   24.6 27.6

                                  47.4

           Note: You can attach the P3GA-11 Back-connecting Socket for finger protection.

Waterproof Packing                         The Waterproof Packing is provided only with the E5CC.
Y92S-P8 (for DIN 48 48)                   Order the Waterproof Packing separately if it becomes lost or damaged.
                                            The Waterproof Packing can be used to achieve an IP66 degree of protection.
                                            (Deterioration, shrinking, or hardening of the waterproof packing may occur depending on the
                                            operating environment. Therefore, periodic replacement is recommended to ensure the level of
                                            waterproofing specified in IP66. The time for periodic replacement depends on the operating
                                            environment. Be sure to confirm this point at your site.
                                            Consider three years as a rough standard.)
                                            The Waterproof Packing does not need to be attached if a waterproof structure is not required.
                                            The E5CC-U cannot be waterproofed even if the Waterproof Packing is attached.

                                                                                                                                                                                                          29
E5CC/E5CC-U

Current Transformers                                                     21                                                        Thru-current (Io) vs. Output Voltage (Eo)
E54-CT1
                                                                          15    5.8 dia.                   2.8                      (Reference Values)
                                                               25 3                                                   7.5
                                                                                                                                    E54-CT1
                                                                      10
                                                                                                                                    Maximum continuous heater current: 50 A (50/60 Hz)
E54-CT3
                                                                                                                                    Number of windings:                                                4002
                                                               40 40
                                                                                                                                    Winding resistance:                                                182

                                                                                                   10.5                             Output voltage (Eo) V (r.m.s.)  100V Frequency: 50 Hz

                                                                          40                                                                                              10                                Distortion
                                                                                            Two, 3.5 dia.                                                                  1
                                                                                                                                                                                 1k                         factor
                                                                                                                                                                    100mV
                                                                                                                                                                                                            10%

                                                                                                                                                                                                             3%
                                                                                                                                                                                                         1%

                                                                           30                                                                                       10                          100

                                                                                                             2.36 dia.                                              1                           RL=10
                                                                          30

                                                                                           12 dia.
                                                                                                                                 9

                                                                                                                                                                    100V

                                                                                                                                                                    10        1  10 100mA 1          10     100 1,000A

                                                                                                                                                                                                Thru-current (Io) A (r.m.s.)

                                                                                                                                    Thru-current (Io) vs. Output Voltage (Eo)

                                                                 Two, M3 (depth: 4)                                                 (Reference Values)
                         15
                                                                                                                                    E54-CT3
                                                 30
                                                                                                                                    Maximum continuous heater current: 120 A (50/60 Hz)

                                                                                                                                    (Maximum continuous heater current for an OMRON
                                                                                                                                    Digital Temperature Controller is 50 A.)

E54-CT3 Accessories                                                                                                                 Number of windings:                                              4002
Armature
                                                                          Connection Example                                        Winding resistance:                                              80.8
  Approx. 3 dia.
                                                                                          Armature                                  Output voltage (Eo) V (r.m.s.)  100V Frequency: 50 Hz

                                                                          Plug                                                                                      10                                              Distortion
                                                                                                                                                                                 1k                                 factor
                                                                                                                                                                                                                    10%
                                                                                                           Lead                                                                  500
                                                                                                                                                                                                                   3%
                                                                                                                                                                    1                                            1%

Plug               18                                                                                                                                             100mV                        100
                (22)                                                                                                                                                      10                    50
Approx. 6 dia.                                                                                                                                                             1
                                                                                                                                                                                                RL=10

                                                                                                                                                                    100V         10 100mA    1       10     100 1,000A
                                                                                                                                                                         10
                                                                                                                                                                            1

                                                                                                                                                                                                Thru-current (Io) A (r.m.s.)

30
                                                                                                          E5CC/E5CC-U

Adapter  Note: 1. Use this Adapter when the Front Panel has already been prepared for the E5B@.
                  2. Only black is available.
Y92F-45           3. You cannot use the E58-CIFQ2 USB-Serial Conversion Cable if you use the Y92F-45 Adapter. To use the USB-Serial
                      Conversion Cable to make the settings, do so before you mount the Temperature Controller in the panel.

                                                                                             Fixture (Accessory)

                                                   4.7                              76

                                                                               69.6 to 77.6

                             72 72

                                                                                             67 67 87

Mounted to E5CC                                    Panel (1 to 8 mm)                    Mounting Adapter
                                                                                        Y92F-30
                             72 72                                                    (Accessory)

                                          48 48

                                          2.2           4.7

                                                                  62.8
                                                        To back of the E5CC

DIN Track Mounting Adapter

Y92F-52   Note: This Adapter cannot be used together with the Terminal Cover.
                  Remove the Terminal Cover to use the Adapter.

                                                                                             This Adapter is used to mount the

                                                                                                 E5CC to a DIN Track.

                                                                               61

                                                                                                 If you use the Adapter, there is no

                                                                                             need for a plate to mount in the

                                                                                             panel or to drill mounting holes in

                                                                               3.5           the panel.

                             50                    38

Mounted to E5CC

                                      48

                                                             80.5

                                                                                                                                      31
E5CC/E5CC-U                                                                                  21.9 14                               Mounting Adapter
                                                                                              (2)
Watertight Cover                                                                                                                 Y92F-49
                                                                                                                 69
Y92A-48N                                                                                                                                                               The Mounting Adapter is provided with the
                                                                                                                   12                                                  Temperature Controller.
                   87.7 79.2                                                                                                                                           Order this Adapter separately if it becomes
                                                  67.6                                                                                                                 lost or damaged.

Protective Cover                                                                                                                  Protective Cover

Y92A-48D  Note: This Protective Cover cannot be used Y92A-48H

                  if the Waterproof Packing is installed.                                                                                                                       This Protective Cover is hard type.

                   This Protective Cover is soft type.                                                                                                                          Please use it for the mis-operation
                   It is able to operate the controller with using                                                                                                              prevention etc.

                   this cover.

E5CC-U Wiring Socket

Front-connecting Socket                                                                                 3                         4.5   Terminal Layout/Internal Connections
P2CF-11                                                                                      7.8
                                                                                                                                                                     (Top View)
                                                               Eleven, M3.5 7.5
                                                               sems screws

                                                                                                                                                                     8765                                Mounting Holes
                                                                                                                                                                                 4
                                                                                                                                                                                                          Two, 4.5 dia. mounting holes
                                                        70 max.                                                                   35.4
                                                                                                                                                                                                                      400.2
                                                                                             Two,                                                                    9          3
                                                                                             4.5-dia.                                                                                          Note: Can also be mounted
                                                                                             holes                                                                   10 11 1 2                         to a DIN track

                                                        4        50 max.                                               31.2 max.

Note: 1. A model with finger protection (P2CF-11-E) is also available.

    2. You cannot use the P2CF-11 or P2CF-11-E together with the Y92F-45.

Back-connecting Socket                                                                                                                  Eleven, M3.5 Terminal Layout/Internal Connections
P3GA-11                                                                                                                                                 sems screws
                                                                                                                                  4 73                                              (Bottom View)
                                                                                     27dia.
                                                                                                                                                                                     5 678
                                                                     45                                                                                                             4

                                                                                       45                         25.6                                                              3  9
                                                                                             4.5 16.3 6.2
                                                                                                                                                                                    2 1 11 10

                                                                                                                                                                  6
                                                                                                                        8.7

Note: 1. Using any other sockets will adversely affect accuracy. Use only the specified sockets.
        2. A Protective Cover for finger protection (Y92A-48G) is also available.
        3. You cannot use the P3GA-11 together with the Y92F-45.

32
MEMO

                                            33
    Digital Temperature Controller

    E5EC/E5AC (48 96 mm/96 96 mm)

Large White PV Display That's Easier to Read.
Easy to Use, from Model Selection to
Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.

    A white LCD PV display with a height of approx. 18 mm for the

    E5EC and 25 mm for the E5AC improves visibility.

    Tool ports are provided both on the top panel and the front panel.

    Set up the Controller without wiring the power supply by                  48 96 mm         96 96 mm
    connecting to the computer with a Communications Conversion                   E5EC               E5AC
    Cable (sold separately). Setup is easy with the CX-Thermo (sold

     separately).                                                             Refer to your OMRON website for the most recent
    High-speed sampling at 50 ms.                                           information on applicable safety standards.

    Models are available with up to 4 auxiliary outputs, up to 6 event

    inputs, a transfer output, and a remote SP input to cover a wide          Refer to Safety Precautions on page 104.

    range of applications.

    Short body with depth of only 60 mm.

    Easy connections to a PLC with programless communications.

    Use component communications to link Temperature Controllers to each other.

    The new position-proportional control models allow you to control valves as well.

Main I/O Functions

    Sensor Input                            E5EC      E5AC
      Universal input
                                                                              Three-level Display       4-digit
    Thermocouple                                                            PV, SV, and MV displayed  displays
    Pt                                                                      at the same time.
    Analog current/voltage
                                                                              Control Output 1
          Indication Accuracy
          Thermocouple input:                                                Relay output
          0.3% of PV                                                          Voltage output (for driving SSR)
          Pt input: 0.2% of PV                                              Linear current output
          Analog input: 0.2% of FS
                                                                              Control Output 2
          Sampling Period
          50 ms                                                             Voltage output (for driving SSR)
                                                                               Relay output
     Event Inputs                                                             Linear current output
    None
    2                                       PF (shift) Key                  Auxiliary Outputs
    4                                       Setup Tool port on front panel  4
    6                                       Temperature status display
                                             Simple programming              Transfer Output
    Remote SP Input                         Independent heating and          None
    None                                                                    1
    1                                       cooling PID control
                                             Changed parameter display
    Serial Communications                   Display brightness setting
    None
    RS-485

    This datasheet is provided as a guideline for selecting products.
    Be sure to refer to the following manuals for application precautions and other information required for operation before attempting
    to use the product.

       E5@C Digital Temperature Controllers User's Manual (Cat. No. H174)
       E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)

34
                                                                                                                                 E5EC/E5AC

Model Number Legend and Standard Models

Model Number Legend

Models with Screw Terminals
E5EC-@@ 4 @ 5 M -@@@ (Example: E5EC-RX4A5M-000)

           -- - - - - ---
             A BC DE F

E5AC-@@ 4 @ 5 M -@@@ (Example: E5AC-RX4A5M-000)

           -- - - - - ---
             A BC DE F

                A                      B          C         D                  E   F

Model           Control outputs     No. of auxil- Power  Terminal           Input  Options                   Meaning
                      1 and 2         iary out- supply     type             type
                                        puts voltage

E5EC                                                                                                         48 96 mm

E5AC                                                                                                         96 96 mm

                                                                                                      Control output 1           Control output 2

            RX                                                                                        Relay output                    None

            QX                                                                                         Voltage output                 None
                                                                                                      (for driving SSR)

        *2 CX                                                                                    Linear current output                None

            QQ                                                                                         Voltage output             Voltage output
                                                                                                      (for driving SSR)          (for driving SSR)

            QR                                                                                         Voltage output            Relay output
                                                                                                      (for driving SSR)

            RR                                                                                        Relay output               Relay output

        *2 CC                                                                                    Linear current output           Linear current out-
                                                                                                                                           put

        *2 CQ                                                                                    Linear current output            Voltage output
                                                                                                                                 (for driving SSR)

            PR                                                                              Position-proportional relay output   Position-proportion-
                                                                                                                                    al relay output

                                 *3 4                                                       4 (auxiliary outputs 1 and 2 with same common and auxilia-
                                                                                                         ry outputs 3 and 4 with same common)

                                               A                                                        100 to 240 VAC

                                               D                                                             24 VAC/DC

                                                         5                                            Screw terminals (with cover)

                Control outputs 1 and 2                                     M                           Universal input

            For RX,                 For PR                                                  HB alarm  Communications     Event   Remote Transfer
            QX, QQ, For CX or                                                               and                          inputs  SP Input output
            QR, RR, or CC                                                                   HS alarm
            CQ

            Selectable Selectable Selectable                                       000      ---         ---              ---     ---        ---

Option                  Selectable Selectable                                      004      ---         RS-485           2       ---        ---

selection               Selectable                                                 005      ---         ---              4       ---        ---

conditions                                                                                  2

*1          Selectable                                                             009 (for 3-phase RS-485               2       ---        ---

                                                                                            heaters)

            Selectable                                                             010      1           ---              4       ---        ---

            Selectable                                                             011      1           ---              6 Provided. Provided.

                        Selectable                                                 013      ---         ---              6 Provided. Provided.

                        Selectable Selectable                                      014      ---         RS-485           4 Provided. Provided.

*1. The options that can be selected depend on the type of control output.
*2. The control output cannot be used as a transfer output.
*3. A model with four auxiliary outputs must be selected.

Heating and Cooling Control

l Using Heating and Cooling Control

A Control Output Assignment
If there is no control output 2, an auxiliary output is used as the cooling control output.
If there is a control output 2, the two control outputs are used for heating and cooling.
(It does not matter which output is used for heating and which output is used for cooling.)
B Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.

                                                                                                                                                      35
E5EC/E5AC

Optional Products (Order Separately)                                  Current Transformers (CTs)

USB-Serial Conversion Cable                                           Hole diameter   Model
                                                                          5.8 mm     E54-CT1
                      Model                                               12.0 mm    E54-CT3
                   E58-CIFQ2

Communications Conversion Cable                                       CX-Thermo Support Software

                      Model                                                                 Model
                 E58-CIFQ2-E                                                           EST2-2C-MV4

Note: Always use this product together with the E58-CIFQ2.            Note: CX-Thermo version 4.5 or higher is required for the E5EC/
        This Cable is used to connect to the front-panel Setup Tool           E5AC.
        port.                                                                 For the system requirements for the CX-Thermo, refer to
                                                                              information on the EST2-2C-MV4 on the OMRON website
Terminal Covers                                                               (www.ia.omron.com).

                      Model
              E53-COV24 (3pcs)

Note: The Terminal Covers E53-COV24 are provided with the Digital
        Temperature Controller.

Waterproof Packing

    Applicable Controller  Model

    E5EC                   Y92S-P9
    E5AC                   Y92S-P10

Note: This Waterproof Packing is provided with the Digital
        Temperature Controller.

Waterproof Cover             Model
                           Y92A-49N
Applicable Controller     Y92A-96N
             E5EC
             E5AC

Front Port Cover

                      Model
                     Y92S-P7
Note: This Front Port Cover is provided with the Digital Temperature
        Controller.

Mounting Adapter

                      Model
                Y92F-51 (2pcs)
Note: This Mounting Adapter is provided with the Digital Temperature
        Controller.

36
Specifications            E5EC                                                                   E5EC/E5AC
Ratings                   E5AC
                                     A in model number: 100 to 240 VAC, 50/60 Hz
Power supply voltage                D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range             85% to 110% of rated supply voltage
                                     Models with option selection of 000:6.6 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or
Power consumption
                                                                                     2.3 W max. at 24 VDC
Sensor input                         All other models: 8.3 VA max. at 100 to 240 VAC, and 5.5 VA max. at 24 VAC or 3.2 W max. at 24 VDC
                                     Models with option selection of 000:7.0 VA max. at 100 to 240 VAC, and 4.2 VA max. at 24 VAC or
Input impedance
                                                                                     2.4 W max. at 24 VDC
Control method                       All other models: 9.0 VA max. at 100 to 240 VAC, and 5.6 VA max. at 24 VAC or 3.4 W max. at 24 VDC
                                     Temperature input
Control       Relay output           Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
output                               Platinum resistance thermometer: Pt100 or JPt100
              Voltage output         Infrared temperature sensor (ES1B): 10 to 70C, 60 to 120C, 115 to 165C, or 140 to 260C
Auxiliary     (for driving SSR)      Analog input
output        Linear current output  Current input: 4 to 20 mA or 0 to 20 mA
              Number of outputs      Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
                                     Current input: 150  max., Voltage input: 1 M min.
              Output specifications  (Use a 1:1 connection when connecting the ES2-HB/THB.)
                                     ON/OFF or 2-PID control (with auto-tuning)
              Number of inputs       SPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations,
                                     minimum applicable load: 5 V, 10 mA (reference value)
Event input External contact input   Output voltage: 12 VDC 20% (PNP), max. load current: 40 mA, with short-circuit protection circuit
                   specifications    (The maximum load current is 21 mA for models with two control outputs.)
                                     4 to 20 mA DC/0 to 20 mA DC, load: 500  max., resolution: approx. 10,000
Transfer      Number of outputs      4
output        Output specifications  SPST-NO. relay outputs, 250 VAC, Models with 4 outputs: 2 A (resistive load),
                                     Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value)
Remote SP input                      2, 4 or 6 (depends on model)
                                     Contact input: ON: 1 k max., OFF: 100 k min.
Potentiometer input                  Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Setting method                       Current flow: Approx. 7 mA per contact
                                     1 (only on models with a transfer output)
Indication method                    Current output: 4 to 20 mA DC, Load: 500  max., Resolution: Approx. 10,000
                                     Linear voltage output: 1 to 5 VDC, load: 1 k min., Resolution: Approx. 10,000
Multi SP                             Current input: 4 to 20 mA DC or 0 to 20 mA DC (input impedance: 150  max.)
Bank switching                       Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V (input impedance: 1 M min.)
                                     100  to 10 k
Other functions                      Digital setting using front panel keys
                                     11-segment digital display and individual indicators
Ambient operating temperature        Character height: E5EC: PV: 18.0 mm, SV: 11.0 mm, MV: 7.8 mm

Ambient operating humidity                                     E5AC: PV: 25.0 mm, SV: 15.0 mm, MV: 9.5 mm
Storage temperature                  Three displays Contents: PV/SV/MV, PV/SV/Multi-SP, or PV/SV/Remaining soak time
Altitude                             Numbers of digits: 4 digits each for PM, SV, and MV displays
Recommended fuse                     Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations,
Installation environment             or serial communications.
                                     None
                                     Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater
                                     burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital
                                     filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root,
                                     MV change rate limit, logic operations, temperature status display, simple programming, moving av-
                                     erage of input value, and display brightness setting
                                     -10 to 55C (with no condensation or icing), For 3-year warranty: -10 to 50C with standard mounting
                                     (with no condensation or icing)
                                     25% to 85%
                                     -25 to 65C (with no condensation or icing)
                                     2,000 m max.
                                     T2A, 250 VAC, time-lag, low-breaking capacity
                                     Installation Category II, Pollution Degree 2 (IEC 61010-1 compliant)

                                     37
E5EC/E5AC

Input Ranges

Thermocouple/Platinum Resistance Thermometer (Universal inputs)

    Sensor                                        Platinum resistance                                                  Thermocouple                                                               Infrared temperature
      type                                             thermometer                                                                                                                                         sensor

    Sensor                                                                                                                                                                                        10 to  60 to 115 to 140 to
                                                                                                                                                                                                  70C   120C 165C 260C
    specifica-                                    Pt100         JPt100               K              J           T  EL                             U          N      R     S     B     W     PLII

                            tion

                                  2300                                                                                                                                                2300
                                  1800
                                  1700                                                                                                                                          1800

                                                                                                                                                                    1700  1700

                                  1600

    Temperature range (C)        1500

                                  1400                                         1300                                                                          1300                           1300
                                  1300

                                  1200

                                  1100

                                  1000                                                         850                                          850
                                             850

                                   900

                                  800

                                  700                                                                                                  600
                                                                                                       400.0 400 400.0
                                  600             500.0         500.0                   500.0

                                  500                                                                                                             400 400.0

                                  400                                                                                                                                                                                                         260
                                                                                                                                                                                                                         120 165
                                  300                                                                                                                                                                          90
                                                                                                                                                                                100
                                  200                    100.0          100.0

                                  100

                                  -100                   0.0            0.0                                                                                         0     0           0     0     0      0  0  0

                                  -200                                                  -20.0 -100 -20.0                                    -100

                                        -200 -199.9             -199.9         -200                        -200 -199.9 -200                       -200 -199.9 -200

    Set value 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

                            Shaded settings are the default settings.

The applicable standards for the input types are as follows:                                           JPt100: JIS C 1604-1989, JIS C 1606-1989
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 60584-1                                                   Pt100: JIS C 1604-1997, IEC 60751
L: Fe-CuNi, DIN 43710-1985                                                                             PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)
U: Cu-CuNi, DIN 43710-1985
W: W5Re/W26Re, ASTM E988-1990

Analog input

       Input type                                            Current                                   Voltage
    Input
    specification                                 4 to 20 mA 0 to 20 mA 1 to 5 V 0 to 5 V 0 to 10 V

    Setting range                                 Usable in the following ranges by scaling:
                                                  -1999 to 9999, -199.9 to 999.9,
    Set value                                     -19.99 to 99.99 or -1.999 to 9.999

                                                         25             26              27             28          29

38
                                                                                                                                  E5EC/E5AC

Alarm Types

Each alarm can be independently set to one of the following 19 alarm types. The default is 2: Upper limit. (see note.)
Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed.

        To use alarm 1, set the output assignment to alarm 1.

Set                                                     Alarm output operation
value
               Alarm type              When alarm value X When alarm value X                                      Description of function

                                            is positive                        is negative

0 Alarm function OFF                                              Output OFF                    No alarm

                                       ON                LH                                     Set the upward deviation in the set point for the alarm upper
                                       OFF                                                      limit (H) and the lower deviation in the set point for the alarm
1          Upper- and lower-limit *1                              PV *2                         lower limit (L). The alarm is ON when the PV is outside this
                                                                                                deviation range.
                                                         SP

    2                                  ON                      X          ON   X                  Set the upward deviation in the set point by setting the alarm
(default)                              OFF                                                  PV value (X). The alarm is ON when the PV is higher than the
           Upper-limit                                            PV      OFF

                                                         SP                    SP               SP by the deviation or more.

                                       ON                X                ON         X          Set the downward deviation in the set point by setting the

3 Lower-limit                          OFF                        PV      OFF               PV alarm value (X). The alarm is ON when the PV is lower than
                                                           SP
                                                                               SP               the SP by the deviation or more.

           Upper- and lower-limit      ON                LH                                     Set the upward deviation in the set point for the alarm upper
           range *1                    OFF                                                      limit (H) and the lower deviation in the set point for the alarm
4                                                                 PV *3                         lower limit (L). The alarm is ON when the PV is inside this de-
                                                                                                viation range.
                                                         SP

5          Upper- and lower-limit      ON                LH       PV *4                         A standby sequence is added to the upper- and lower-limit
                                                          SP                                    alarm (1). *6
           with standby sequence *1 *5 OFF

           Upper-limit with standby    ON                      X          ON   X
           sequence                    OFF
6                                                                 PV      OFF               PV A standby sequence is added to the upper-limit alarm (2). *6

                                                         SP                    SP

7          Lower-limit with standby    ON                X                ON       X
           sequence                    OFF                SP
                                                                  PV      OFF            PV A standby sequence is added to the lower-limit alarm (3). *6

                                                                               SP

           Absolute-value upper-lim- ON                     X             ON      X             The alarm will turn ON if the process value is larger than the

8          it                          OFF                        PV      OFF           0 PV alarm value (X) regardless of the set point.
                                                      0

                                       ON                   X             ON      X             The alarm will turn ON if the process value is smaller than the
                                       OFF
9          Absolute-value lower-limit                             PV      OFF           0 PV alarm value (X) regardless of the set point.

                                            0

           Absolute-value upper-lim- ON                     X             ON      X             A standby sequence is added to the absolute-value upper-

10         it with standby sequence OFF 0                         PV      OFF           0 PV limit alarm (8). *6

           Absolute-value lower-limit ON                    X             ON      X             A standby sequence is added to the absolute-value lower-

11         with standby sequence       OFF                        PV      OFF           0 PV limit alarm (9). *6
                                                      0

12 LBA (alarm 1 type only)                                             -                        *7

13 PV change rate alarm                                                -                        *8

           SP absolute-value           ON        X                        ON      X             This alarm type turns ON the alarm when the set point (SP)
           upper-limit alarm           OFF  0
14                                                                SP      OFF           0 SP is higher than the alarm value (X).

           SP absolute-value           ON        X                        ON      X             This alarm type turns ON the alarm when the set point (SP)
           lower-limit alarm           OFF  0
15                                                                SP      OFF           0 SP is lower than the alarm value (X).

                                       Standard Control Standard Control

                                       ON                   X             ON      X

                                       OFF                        MV      OFF               MV
                                                      0
           MV absolute-value                                                            0       This alarm type turns ON the alarm when the manipulated
           upper-limit alarm *9
16                                     Heating/Cooling                    Heating/Cooling       variable (MV) is higher than the alarm value (X).

                                       Control (Heating MV) Control (Heating MV)

                                       ON                   X

                                       OFF                        MV Always ON
                                                      0

                                       Standard Control Standard Control

                                       ON                   X             ON      X

                                       OFF  0                     MV      OFF           0   MV

17         MV absolute-value           Heating/Cooling                    Heating/Cooling       This alarm type turns ON the alarm when the manipulated
           lower-limit alarm *9        Control (Cooling MV)               Control (Cooling MV)  variable (MV) is lower than the alarm value (X).

                                       ON                   X

                                       OFF                        MV Always ON
                                                      0

           RSP absolute-value          ON        X                        ON      X             This alarm type turns ON the alarm when the remote SP
           upper-limit alarm *10       OFF  0                             OFF
18                                                                RSP                   0 RSP (RSP) is higher than the alarm value (X).

           RSP absolute-value          ON        X                        ON      X             This alarm type turns ON the alarm when the remote SP
           lower-limit alarm *10       OFF  0                             OFF
19                                                                RSP                   0 RSP (RSP) is lower than the alarm value (X).

                                                                                                                                                                  39
E5EC/E5AC

*1 With set values 1, 4 and 5, the upper and lower limit values can be set  *4. Set value: 5, Upper- and lower-limit with standby sequence
     independently for each alarm type, and are expressed as "L" and "H."
                                                                                    For Upper- and Lower-Limit Alarm Described Above *2
*2. Set value: 1, Upper- and lower-limit alarm
                                                                                  Case 1 and 2
    Case 1          Case 2          Case 3 (Always ON)                              Always OFF when the upper-limit and lower-limit hysteresis overlaps.

      L H SP        SP L H                        H SP L  H<0, L<0                Case 3: Always OFF
                                                H L SP
    H<0, L>0         H>0, L<0                             H<0, L>0          *5. Set value: 5, Upper- and lower-limit with standby sequence
    |H| < |L|         |H| > |L|                            |H|  |L|               Always OFF when the upper-limit and lower-limit hysteresis overlaps.
                                                          H>0, L<0
                                                SP H L     |H|  |L|         *6. Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.
                                                                                  H174) for information on the operation of the standby sequence.
*3. Set value: 4, Upper- and lower-limit range
                                                                            *7. Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.
    Case 1          Case 2          Case 3 (Always OFF)   H<0, L<0                H174) for information on the loop burnout alarm (LBA). This setting cannot
                                                                                  be used with a position-proportional model.
           L H SP     SP L H               H SP L         H<0, L>0
        H<0, L>0        H>0, L<0        H L SP             |H|  |L|         *8. Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.
         |H| < |L|       |H| > |L|                                                H174) for information on the PV change rate alarm.

                                                SP H L    H>0, L<0          *9. When heating/cooling control is performed, the MV absolute upper limit
                                                           |H|  |L|               alarm functions only for the heating operation and the MV absolute lower
                                                                                  limit alarm functions only for the cooling operation.

                                                                            *10. This value is displayed only when a remote SP input is used. It functions in
                                                                                  both Local SP Mode and Remote SP Mode.

40
                                                                                                                    E5EC/E5AC

Characteristics

Indication accuracy                Thermocouple: (0.3% of indication value or 1C, whichever is greater) 1 digit max. *1
(at the ambient temperature of     Platinum resistance thermometer: (0.2% of indication value or 0.8C, whichever is greater) 1 digit max.
23C)                              Analog input: 0.2% FS 1 digit max.
                                   CT input: 5% FS 1 digit max.
                                   Potentiometer input: 5% FS 1 digit max.

Transfer output accuracy           0.3% FS max.

Remote SP Input Type               0.2% FS 1 digit max.

Influence of temperature *2        Thermocouple input (R, S, B, W, PL II): (1% of indication value or 10C, whichever is greater) 1 digit
Influence of voltage *2            max.
                                   Other thermocouple input: (1% of indication value or 4C, whichever is greater) 1 digit max. *3
                                   Platinum resistance thermometer: (1% of indication value or 2C, whichever is greater) 1 digit max.
                                   Analog input: 1%FS 1 digit max.
                                   CT input: 5% FS 1 digit max.
                                   Remote SP input: 1% FS 1 digit max.

Input sampling period              50ms

Hysteresis                         Temperature input: 0.1 to 999.9C or F (in units of 0.1C orF)
                                   Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

Proportional band (P)              Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                   Analog input: 0.1 to 999.9% FS (in units of 0.1% FS)

Integral time (I)                  Standard, heating/cooling, or Position-proportional (Close): 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in
                                   units of 0.1 s)
                                   Position-proportional (Floating): 1 to 9999 s (in units of 1 s), 0.1 to 999.9 s (in units of 0.1 s)*4

Derivative time (D)                0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Proportional band (P) for cooling  Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                   Analog input: 0.1 to 999.9% FS (in units of 0.1% FS)

Integral time (I) for cooling      0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D) for cooling    0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Control period                     0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)

Manual reset value                 0.0 to 100.0% (in units of 0.1%)

Alarm setting range                -1999 to 9999 (decimal point position depends on input type)

Influence of signal source resis-  Thermocouple: 0.1C/ max. (100  max.)
tance                              Platinum resistance thermometer: 0.1C/ max. (10  max.)

Insulation resistance              20 M min. (at 500 VDC)

Dielectric strength                3,000 VAC, 50/60 Hz for 1 min between terminals of different charge

Vibration   Malfunction            10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
            Resistance             10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions

Shock       Malfunction            100 m/s2, 3 times each in X, Y, and Z directions
            Resistance             300 m/s2, 3 times each in X, Y, and Z directions

Weight                 E5EC        Controller: Approx. 210 g, Adapter: Approx. 4 g 2
                       E5AC        Controller: Approx. 250 g, Adapter: Approx. 4 g 2

Degree of protection               Front panel: IP66, Rear case: IP20, Terminals: IP00

Memory protection                  Non-volatile memory (number of writes: 1,000,000 times)

Setup Tool                         CX-Thermo version 4.5 or higher

Setup Tool port                    E5EC/E5AC top panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect to a USB port
                                                                     on the computer.*5

                                   E5EC/E5AC front panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion
                                                                     Cable are used together to connect to a USB port on the computer.*5

                  Approved standards UL 61010-1, Korean Radio Waves Act (Act 10564)
Standards

                  Conformed standards EN 61010-1 (IEC 61010-1): Pollution Degree 2, overvoltage category II, Lloyd's standards *6

                                   EMI                                                  EN61326

                                   Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A

                                   Noise Terminal Voltage:                              EN 55011 Group 1, class A

                                   EMS:                                                 EN 61326

EMC                                ESD Immunity:                                        EN 61000-4-2

                                   Electromagnetic Field Immunity:                      EN 61000-4-3

                                   Burst Noise Immunity:                                EN 61000-4-4

                                   Conducted Disturbance Immunity:                      EN 61000-4-6

                                   Surge Immunity:                                      EN 61000-4-5

                                   Voltage Dip/Interrupting Immunity:                   EN 61000-4-11

*1 The indication accuracy of K thermocouples in the -200 to 1,300C range, T and N thermocouples at a temperature of -100C max., and U and L thermocouples
     at any temperatures is 2C 1 digit max. The indication accuracy of the B thermocouple at a temperature of 400C max.
     is not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800C is 3C max. The indication accuracy of the R and S thermocouples
     at a temperature of 200C max. is 3C 1 digit max. The indication accuracy of W thermocouples is (0.3% of PV or 3C, whichever is greater) 1 digit max. The
     indication accuracy of PL II thermocouples is (0.3% of PV or 2C, whichever is greater) 1 digit max.

*2 Ambient temperature: -10C to 23C to 55C, Voltage range: -15% to 10% of rated voltage
*3 K thermocouple at -100C max.: 10C max.
*4 The unit is determined by the setting of the Integral/Derivative Time Unit parameter.

*5 External communications (RS-485) and USB-serial conversion cable communications can be used at the same time.

*6 Refer to information on maritime standards in Shipping Standards on page 106 for compliance with Lloyd's Standards.

                                                                                                                                                   41
E5EC/E5AC

USB-Serial Conversion Cable                                                                                               When Digital Temperature Controllers are con-
                                                                                                                          nected, set points and RUN/STOP commands
    Applicable OS        Windows XP/Vista/7/8                                                                             can be sent from the Digital Temperature Control-
                                                                                                                          ler that is set as the master to the Digital Temper-
    Applicable software  CX-Thermo version 4.5 or higher                           Component                              ature Controllers that are set as slaves.
                                                                                   Communications*1                       Slope and offsets can be set for the set point.
                                                                                                                          Number of connected Digital Temperature Con-
    Applicable models    E5@C-T Series, E5@C Series, and E5CB Series                                                      trollers: 32 max. (including master)

    USB interface standard Conforms to USB Specification 2.0.

    DTE speed            38,400 bps                                                                                       When Digital Temperature Controllers are con-
                                                                                                                          nected, the parameters can be copied from the
    Connector            Computer: USB (type A plug)                               Copying*2                              Digital Temperature Controller that is set as the
    specifications       Digital Temperature Controller:                                                                  master to the Digital Temperature Controllers that
                         Special serial connector                                                                         are set as slaves.

    Power supply         Bus power (Supplied from USB host controller.)*           MELSEC is a registered trademark of Mitsubishi Electric Corporation.

    Power supply voltage 5 VDC                                                     KEYENCE is a registered trademark of Keyence Corporation.

    Current consumption  450 mA max.                                               *1 A Temperature Controller with version 1.1 or higher is required.
    Output voltage                                                                      A Temperature Controller with version 2.1 or higher is required for
                         4.70.2 VDC                                                    the FX Series or the KV Series.
                         (Supplied from USB-Serial Conversion Cable to
                         the Digital Temperature Controller.)                      *2 Both the programless communications and the component
                                                                                        communications support the copying.
    Output current       250 mA max.
                         (Supplied from USB-Serial Conversion Cable to
                         the Digital Temperature Controller.)

    Ambient operating    0 to 55C (with no condensation or icing)                 Current Transformer (Order Separately)
    temperature                                                                    Ratings

    Ambient operating    10% to 80%
    humidity
                                                                                   Dielectric strength                    1,000 VAC for 1 min
    Storage temperature -20 to 60C (with no condensation or icing)                Vibration resistance                   50 Hz, 98 m/s2

    Storage humidity     10% to 80%                                                Weight                                 E54-CT1: Approx. 11.5 g,
                                                                                                                          E54-CT3: Approx. 50 g
    Altitude             2,000 m max.                                              Accessories
                                                                                   (E54-CT3 only)                         Armatures (2)
    Weight               Approx. 120 g                                                                                    Plugs (2)

Windows is a registered trademark of Microsoft Corporation in the                  Heater Burnout Alarms and SSR Failure
                                                                                   Alarms
United States and or other countries.

* Use a high-power port for the USB port.

Note: A driver must be installed on the computer. Refer to the
        Instruction Manual included with the Cable for the installation
        procedure.

Communications Specifications                                                      CT input (for heater                   Models with detection for singlephase
                                                                                   current detection)                     heaters: One input
                                                                                                                          Models with detection for singlephase or
    Transmission line    RS-485: Multidrop                                                                                three-phase heaters: Two inputs
    connection method
                                                                                   Maximum heater
    Communications       RS-485 (two-wire, half duplex)                            current                                50 A AC

    Synchronization      Start-stop synchronization                                Input current indica-                  5% FS 1 digit max.
    method                                                                         tion accuracy

    Protocol             CompoWay/F, or Modbus

    Baud rate*           9600, 19200, 38400, or 57600 bps                          Heater burnout                         0.1 to 49.9 A (in units of 0.1 A)
                                                                                   alarm setting range                    Minimum detection ON time: 100 ms *3
    Transmission         ASCII                                                     *1
    code

    Data bit length*     7 or 8 bits                                               SSR failure alarm                      0.1 to 49.9 A (in units of 0.1 A)
                                                                                   setting range *2                       Minimum detection OFF time: 100 ms *4
    Stop bit length*     1 or 2 bits

    Error detection      Vertical parity (none, even, odd)                         *1. For heater burnout alarms, the heater current will be measured when the
                         Block check character (BCC) with                                control output is ON, and the output will turn ON if the heater current is
                         CompoWay/F or CRC-16 Modbus                                     lower than the set value (i.e., heater burnout detection current value).

    Flow control         None                                                      *2. For SSR failure alarms, the heater current will be measured when the
                                                                                         control output is OFF, and the output will turn ON if the heater current is
    Interface            RS-485                                                          higher than the set value (i.e., SSR failure detection current value).

    Retry function       None                                                      *3. The value is 30 ms for a control period of 0.1 s or 0.2 s.
                                                                                   *4. The value is 35 ms for a control period of 0.1 s or 0.2 s.
    Communications buffer 217 bytes

    Communications       0 to 99 ms                                                Electrical Life Expectancy Curve for
    response wait time   Default: 20 ms                                            Relays (Reference Values)

* The baud rate, data bit length, stop bit length, and vertical parity can be in-       500
    dividually set using the Communications Setting Level.                              300

Communications Functions                                                           Life ( 104 operations)

                         You can use the memory in the PLC to read and                                      100           E5EC/E5AC
                         write E5@C parameters, start and stop operation,
                         etc. The E5@C automatically performs communi-                                                    250 VAC, 30 VDC
                         cations with PLCs. No communications program-
                         ming is required.                                                                                (resistive load)
                         Number of connected Digital Temperature Con-
                         trollers: 32 max. (Up to 16 for the FX Series)                                     50            cos = 1
                         Applicable PLCs
                                                                                                            30
                            OMRON PLCs
    Programless                 CS Series, CJ Series, or CP Series                                          10
    communications*1                                                                                         5
                            Mitsubishi Electric PLCs                                                         3
                                MELSEC Q Series, L Series, or FX Series
                                (compatible with the FX2 or FX3 (excluding                                  1
                                the FX1S))
                                                                                                                 0  1  2  3  4              5  6
                            KEYENCE PLCs
                                KEYENCE KV Series

                                                                                                                             Switching current (A)

42
                                                                                                                                                                                        E5EC/E5AC

External Connections

E5EC/E5AC

                      E5EC-@@ 4 @ 5 M - @@@ E5AC-@@ 4 @ 5 M - @@@

                                    (1) (2) (3) (4) (5) (6)                                      (1) (2) (3) (4) (5) (6)                                      The E5EC is set for a K-type thermocouple (input
                                                                                                                                                              type = 5) by default. An input error (s.err) will occur
                                                                                                                                                              if the input type setting does not agree with the
                                              Terminal type                                                Terminal type
                                                                                                                                                              temperature sensor. Check the input type.

   Control output 1                Control output 2                Auxiliary outputs 1, 2, 3, 4          (6) Options

  Relay output                  Relay output                       Relay output                                  004                         005                 009                               010
  250 VAC, 5 A                  250 VAC, 5 A                       Models with 4 auxiliary                       Communications              4 event inputs
  (resistive load)              (resistive load)                   outputs: 250 VAC, 2 A                         and 2 event inputs                              Communications, 2 event 4 event inputs
  Voltage output                Voltage output                     (resistive load)
  (for driving SSR)             (for driving SSR)                                                                                                                inputs, and 2 CT inputs and 1 CT input
  12 VDC, 40 mA                 12 VDC, 21 mA
  When There Is a               Linear current output                                                                B(+)                 -            13              B(+)                     -           13
  Control Output 2:             0 to 20 mA DC                                                                                 13                                                13
  21 mA                         4 to 20 mA DC                                                                                                +         14                                      +            14
  Linear current output         Load: 500  max.                                                                  RS-485                   + EV3        15          RS-485                   + EV3           15
  0 to 20 mA DC                                                                                                               14          EV4                                   14           EV4
  4 to 20 mA DC
  Load: 500  max.                                                                                                    A(-)                                              A(-)
                                                                                                                              15                                                15
(1) Control output
                                                                                                                 -      16                -            16          -        16                  -           16

                                                                                                                    +   17                      +      17              +    17                     +        17
                                                                                                                 + EV1                    + EV1                    + EV1
                                                                                                                  EV2   18                EV2          18           EV2     18              + EV1           18
                                                                                                                                                                                             EV2
                                                                                                                        19                             19                   19                              19
                                                                                                                                                                                                CT1
                                                                                                                        20                             20          CT1                                      20

                                                                                                                                                                        COM 20

                                                                                                                        21                             21          CT2      21                              21

   RX                      QX                    CX                                                                               011
                                                                                                                                  6 event Inputs, 1 CT input,
Models with           Models with 1          Models with 1                                                                        transfer output, and remote SP input
1 Relay Output        Voltage Output         Linear Current Output
                      (for Driving SSR)

    3          OUT1 3           +   OUT1     3           +  OUT1    (3) Input Power Supply                                                                    -         13
    4                           -            4           -  C
               R      4             Q                                                                                                                            +      14
                                                                                                                                                              + EV3     15
    5                 5                      5                      100 to 240 VAC               24 VAC/DC
                                                                                    1                        1                            -                   EV4
                                                                                    2                        2                                         28     -         16
    6                 6                      6
                                                                                                  (no polarity)                              +         29        +      17
QQ                                  QR                                                                                                    + EV5        30     + EV1     18
                                                                                                                                                              EV2
Models with 2 Voltage Models with Voltage Output (for                                                                                     EV6
Outputs (for Driving SSR) Driving SSR) and Relay Output
                                                                                                                                             +         31               19
                                                                                                                                  Transfer V +                CT1
                                                                                                                                                       32               20
                                                                                                                                  output           I
               OUT1                       OUT1
    3  +                     3         +                            1 25 13                                                                  -         33               21
    4  -       Q             4         -  Q                         2 26 14
                                                                    3 27 15                                                                  +         34
                                                                    4 28 16                                                                        +
    5  +                     5                                                                                                    Remote V         mA  35
    6  -                     6                                                                                                    SP input
               Q                          R                                                                                                  -         36
                                          OUT2
               OUT2

RR                PR                CC                              5 29 17                                                       013                                       014
                                                                    6 30 18                                                       6 event Inputs, transfer                  Communications, 4 event Inputs,
Models with 2 Models with 2         Models with 2                   7 31 19                                                       output, and remote SP input               transfer output, and remote SP input
                                                                    8 32 20
Relay Outputs Position-proportional Linear Current                  9 33 21
                                                                    10 34 22
       OUT1       Relay Output Open Outputs     OUT1                11 35 23                                                                           -           13                                     B(+)
                                                                    12 36 24                                                                                                                                       13
3      R          3          R3              +  C                                                                                                         +        14
4                                    4       -                               Potentiometer Input                                                       + EV3       15                                 RS-485
                  4                                                                                                                                     EV4                                                        14

                                                                                                                                                                                                          A(-)
                                                                                                                                                                                                                   15

5             5                        5     +  C                                                                                 -                28      -       16             -         28        -         16
6      R                                     -
       OUT2 6                R         6        OUT2                                                                                    + 29              +        17                +      29           +      17
                                                                                                                                                       + EV1       18             + EV5     30     + EV1
                             Close                                                                                                + EV5                EV2                         EV6              EV2
                                                                                                                                  EV6
CQ                                                                                                                                                 30                                                           18

Models with 2 Outputs: Linear Current Output                                                                                         +             31              19                +      31                  19
and Voltage (for Driving SSR)                                                                                           Transfer V +                                      Transfer V +
                                                                                                                                                   32              20                       32                  20
                                                                                                                        output               I                            output        I
               OUT1
    3  +                 (2) Auxiliary Outputs                                                                                       -             33              21                -      33                  21
    4  -       C                  Auxiliary outputs 1, 2, 3, 4
                                                                                                                                     +             34                                +      34
                                                                                         O 19                                                +                                          +
    5  +                                  7                                              W 20                           Remote V             mA    35                     Remote V      mA  35
    6  -                                      Auxiliary output 4                         C 21                           SP inpu-t                  36                     SP input-         36
               Q
                                          8
               OUT2                           Auxiliary output 3

                                          9                                                                                               Note: 1. The application of the terminals depends on
                                                                                                                                                        the model.
                                          10                        (5) Sensor (Temperature/Analog) Input
                                               Auxiliary output 2                                                                                  2. Do not wire the terminals that are shown with
                                                                       TC                            Pt          I            V                         a gray background.
                                          11                                                     A
                                               Auxiliary output 1      22                                  + 22               22                   3. When complying with EMC standards, the
                                                                    - 23                             22  mA 23            - 23                          cable that connects the sensor must be 30 m
                                          12                        + 24                         B                      V 24                            or less. If the cable length exceeds 30 m,
                                                                                                           -              +                             compliance with EMC standards will not be
                                                                                                     23        24                                       possible.
                                                                                                 B 24

                                                                                                                                                      4. Connect M3 crimped terminals.

Isolation/Insulation Block Diagrams

Models with 4 Auxiliary Outputs

       Power          Sensor input, CT inputs, potentiometer input, and remote SP input
       Supply                          Communications and event inputs
                                       Voltage output (for driving SSR),

                                  linear current output, and transfer output

                                                     Relay output
                                               Auxiliary outputs 1, 2
                                               Auxiliary outputs 3, 4

                             : Reinforced insulation
                             : Functional isolation

Note: Auxiliary outputs 1 to 2 and 3 to 4 are not insulated.

                                                                                                                                                                                                                       43
E5EC/E5AC

Nomenclature

E5EC

                                 Front panel

             Temperature unit                                              No. 1 display                                       Top View of E5EC
     Operation indicators                                               PV or specified parameter
                                                                                                                                                                 Top-panel
    Front-panel Setup Tool port                                           No. 2 display                                                                          Setup
                                                                        SP or specified parameter value                                                          Tool port

                                                                           No. 3 display
                                                                        Manipulated value or other value
                                                                         MUansieputhlaeteUd vaDlueKoeryosthtoersveatlue

                                                                          the parameter.

                                                                          Use S Key to change the digit (default setting).

                                                                                Use the M Key to change to another parameter.

    Press O Key once to go to Adjustment Level.

    Press O Key for at least 3 seconds to go to Initial Setting Level.

E5AC

                                 Front Panel

         Temperature unit                                                                                                               Top View of E5AC
     Operation indicators
                                                                                     No. 1 display
    Front-panel Setup Tool port                                                  PV or specified parameter

                                                                                     No. 2 display
                                                                                SP or specified parameter value

                                                                                     No. 3 display
                                                                                Manipulated value or other value

                                                                                Press the U or D Key to set the parameter.                                Top-panel
                                                                                Press the S Key to change the digit (default setting).                    Setup
                                                                                                                                                          Tool port

    Press the O Key once to go to the Adjustment Level.                         Press the M Key to change to another parameter.
    Press the O Key for at least 3 seconds to go to the Initial Setting Level.

44
Dimensions                                                                                                        E5EC/E5AC

Controllers                                                                                                                     (Unit: mm)

E5EC

                            48  4                              (64)                                  44
                                1                               60               110

                96                                                                                            The Setup Tool ports are on the front and top
                                                                                                              of the Digital Temperature Controller.
                                                                                                              It is used to connect the Temperature Con-
                                                                                                              troller to the computer to use the Setup Tool.
                                                                                                              The E58-CIFQ2 USB-Serial Conversion
                                                                                                              Cable is required to make the connection.
                                                                                                         91 Refer to the instructions that are provided
                                                                                                              with the USB-Serial Conversion Cable for the
                                                                                                              connection procedure.

                                                                                                             Note: Do not leave the USB-Serial
                                                                                                                      Conversion Cable connected when
                                                                                                                      you use the Temperature Controller.

                            Waterproof
                            Packing (Accessory) Mounting Adapter

                                                           (Accessory)

      Mounted Separately     Group Mounted *                                     * Selections for Control Outputs 1 and 2: QQ, QR, RR, CC, PR, or CQ
                                                                                     If you also specify 011, 013, or 014 for the option selection and use
                   45+0.06  (48 number of units - 2.5)+10.0                        group mounting, the ambient temperature must be 45C or less.
                                                                                     If the ambient temperature is 55C, maintain the following mounting
                                92+00.8                                              spaces between Controllers.

                                                                                                                        60 min.
                                                                                                             45-00.6

      120 min.              Group mounting does not
                            allow waterproofing.

                                                                                                         92+00.8

                92-00.8

                                                                                 120 min.

       Recommended panel thickness is 1 to 8 mm.

       Group mounting is not possible in the vertical direction. (Maintain the
        specified mounting space between Controllers.)

       To mount the Controller so that it is waterproof, insert the waterproof
        packing onto the Controller.

       When two or more Controllers are mounted, make sure that the
        surrounding temperature does not exceed the allowable operating
        temperature specified in the specifications.

                                                                                                                                                            45
E5EC/E5AC                                                                                                          (64)

E5AC

                                                                                                             4     60

                                                                          96 x 96                               1             91 x 91

                                                                                                                         110  91

                                                                               Waterproof
                                                                               Packing (Accessory) Mounting Adapter

                                                                                                               (Accessory)

                                                 The Setup Tool ports are on the front and top of the Digital Temperature Controller.
                                                 It is used to connect the Temperature Controller to the computer to use the Setup Tool.
                                                 The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection.
                                                 Refer to the instructions that are provided with the USB-Serial Conversion Cable for the connection procedure.

                                                 Note: Do not leave the USB-Serial Conversion Cable connected when you use the Temperature Controller.

               Mounted Separately                    Group Mounted *                                             Recommended panel thickness is 1 to 8 mm.

                               92+00.8           (96 number of units - 3.5)+10.0                               Group mounting is not possible in the vertical direction. (Maintain the
                                                                                                                  specified mounting space between Controllers.)
    120 min.                                                                                        92+00.8
                                                                                                                To mount the Controller so that it is waterproof, insert the waterproof
                                                                                                                  packing onto the Controller.

                                                                                                                When two or more Controllers are mounted, make sure that the
                                                                                                                  surrounding temperature does not exceed the allowable operating
                                                                                                                  temperature specified in the specifications.

                                                 Group mounting does not
                                                 allow waterproofing.

                                        92+00.8

46
                                                                                                                                                                  E5EC/E5AC

Accessories (Order Separately)

USB-Serial Conversion Cable                                                                                             (2110)                                   1510
E58-CIFQ2                                                                                                                                               263

                                                                                                     250

                                                                                                               LED (RD)

                                                       USB connector                                                                                                       Serial connector
                                                       (type A plug)                                                                                                    1510

                                                                                                                         LED (PWR)
                                                                                                                         LED (SD)

Conversion Cable                                                   Connecting to the E58-CIFQ2 USB-Serial Conversion Cable
E58-CIFQ2-E
                                                                                                                         (2110)
              Conversion Cable
                                                                                                          250                                                263
                                               (1510)

                                                                                                               E58-CIFQ2 (Order Separately)                       Conversion Cable

Note: Always use this product together with the E58-CIFQ2.

Terminal Covers                                                     Waterproof Packing
E53-COV24 (Three Covers provided.)                                  Y92S-P9 (for DIN 48 96)

                                                             2 3.8                                                       The Waterproof Packing is provided with the Temperature
                                                  10                                                                     Controller.
                                                                                                                         Order the Waterproof Packing separately if it becomes lost or
                                       91                                                                                damaged.
                                                                                                                         The degree of protection when the Waterproof Packing is used
                                                                    Y92S-P10 (for DIN 96 96)                           is IP66.
                                                                                                                         Also, keep the Port Cover on the front-panel Setup Tool port
                                                                                                                         of the E5EC/E5AC securely closed.
                                                                                                                         To maintain an IP66 degree of protection, the Waterproof
                                                                                                                         Packing and the Port Cover for the front-panel Setup Tool port
                                                                                                                         must be periodically replaced because they may deteriorate,
                                                                                                                         shrink, or harden depending on the operating environment.
                                                                                                                         The replacement period will vary with the operating
                                                                                                                         environment.
                                                                                                                         Check the required period in the actual application.
                                                                                                                         Use 3 years or sooner as a guideline.
                                                                                                                         If a waterproof structure is not required, then the Waterproof
                                                                                                                         Packing does not need to be installed.

Setup Tool Port Cover for top panel                                                                            Mounting Adapter
Y92S-P7                                                                                                        Y92F-51 (Two Adapters provided.)

                                                       Order this Port Cover                                                                                      One pair is provided with the
                                                       separately if the Port Cover on                                                                            Controller.
                                                       the front-panel Setup Tool port                                                                            Order this Adapter
                                                       is lost or damaged. The                                                                                    separately if it becomes lost
                                                       Waterproof Packing must be                                                                                 or damaged.
                                                       periodically replaced because
                                                       it may deteriorate, shrink, or
                                                       harden depending on the
                                                       operating environment.

                                                                                                                                                                                                 47
E5EC/E5AC                                                                                                                            Watertight Cover
                                                                                                                                    Y92A-96N (96 96)
Watertight Cover
Y92A-49N (48 96)

                                                                              21.9  (2)                                                                                                                                                21.9 (2)

                131.7                                                                                                               131.7

                                             67.6                             29.4                                                                                         115.6                                                       29.4

Current Transformers                                                     21                                                               Thru-current (Io) vs. Output Voltage (Eo)
E54-CT1                                                                                                        2.8                         (Reference Values)
                                                                                                                                           E54-CT1
                                                               25 3       15        5.8 dia.

                                                                      10                                            7.5                    Maximum continuous heater current: 50 A (50/60 Hz)

E54-CT3                                                                                                                                    Number of windings:                                                                         4002

                                                               40 40                                                                     Winding resistance:                                                                         182

                                                                                                   10.5                                                                    Output voltage (Eo) V (r.m.s.)  100V Frequency: 50 Hz

                                                                          40                                                                                                                                     10                                  Distortion
                                                                                             Two, 3.5 dia.                                                                                                        1
                                                                                                                                                                                                                               1k                    factor
                                                                                                                                                                                                           100mV
                                                                                                                                                                                                                                                     10%

                                                                                                                                                                                                                                                         3%
                                                                                                                                                                                                                                                     1%

                                                                          30                                                                                                                                   10                      100

                                                                                                             2.36 dia.                                                                                         1                       RL=10
                                                                          30
                                                                                                                                                                                                           100V
                                                                                            12 dia.
                                                                                                                                 9

                                                                                                                                                                                                               101   10 100mA 1                  10  100 1,000A

                                                                           Two, M3 (depth: 4)                                                                                                                 Thru-current (Io) A (r.m.s.)
                                  15
                                                                                                                                           Thru-current (Io) vs. Output Voltage (Eo)
                                                          30                                                                               (Reference Values)
                                                                                                                                           E54-CT3

                                                                                                                                           Maximum continuous heater current: 120 A (50/60 Hz)

                                                                                                                                           (Maximum continuous heater current for an OMRON Digital
                                                                                                                                           Temperature Controller is 50 A.)

                                                                                                                                           Number of windings:                                                                         4002

E54-CT3 Accessories                                                                                                                        Winding resistance:                                                                         80.8
Armature
                                                                          Connection Example                                               Output voltage (Eo) V (r.m.s.)  100V Frequency: 50 Hz
  Approx. 3 dia.
                                                                                              Armature                                                                                                     10                                           Distortion
                                                                                                                                                                                                                     1k                                 factor
                                                                                                                                                                                                                                                        10%
                                                                              Plug                                                                                                                                   500
                                                                                                                                                                                                                                                       3%
                                                                                                                                                                                                           1                                         1%

                                                                                                                    Lead

Plug                        18                                                                                                                                           100mV                                                        100
                       (22)                                                                                                                                                      10                                                    50
Approx. 6 dia.                                                                                                                                                                    1
                                                                                                                                                                                                                                       RL=10

                                                                                                                                                                           100V                                      10 100mA       1        10      100 1,000A
                                                                                                                                                                                10
                                                                                                                                                                                   1

                                                                                                                                                                                                                                       Thru-current (Io) A (r.m.s.)

48
MEMO

                                            49
    Digital Temperature Controller

    E5DC (22.5 mm Wide, and DIN Track-mounting Type)

The E5DC Mounts to DIN Track and Is Ideal
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and
Advanced Performance as the Rest of the
E5@C Series.

    A slim body at 85 22.5 mm (D W) that fits into narrow control

    panels and mounts to DIN Track.

    Removable terminal block for easy replacement to simplify maintenance.

    High-speed sampling at 50 ms for applications with high-speed

    temperature increases.

    Easy connections to a PLC with programless communications.

    Set up the Controller without wiring the power supply by connecting

     to the computer with a Communications Conversion Cable (sold separately).       22.5 mm Wide, and
     Setup is easy with the CX-Thermo (sold separately).                         DIN Track-mounting Type
    Models are available with up to 2 auxiliary outputs and 1 event input to
                                                                                               E5DC

     complete basic functions.                                                   Refer to your OMRON website for the most recent
    A white PV display (height: 8.5 mm) is easy to read when setting up,       information on applicable safety standards.

    checking alarms, and making settings in a control panel.                     Refer to Safety Precautions on page 104.

Main I/O Functions                                              E5DC             Dual displays: PV/SV 4-digit displays

                    Sensor Input                   PF (shift) Key              Control Output 1
                      Universal input               Temperature status display   Relay output
                                                    Simple programming          Voltage output (for driving SSR)
                     Thermocouple                  Independent heating and      Linear current output
                     Pt
                     Analog current/voltage        cooling PID control           Auxiliary Outputs
                                                    Changed parameter display    None
                          Indication Accuracy       Display brightness setting  2
                           Thermocouple input:
                           0.3% of PV
                           Pt input: 0.2% of PV
                           Analog input:
                          0.2% of FS

                           Sampling Period
                           50 ms

                     Event Inputs
                     None
                    1

                     Serial Communications
                     None
                     RS-485

    This datasheet is provided as a guideline for selecting products.
    Be sure to refer to the following manuals for application precautions and other information required for operation before attempting
    to use the product.
    E5@C Digital Temperature Controllers User's Manual (Cat. No. H174)
    E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)

50
                                                                                                                                                E5DC

Model Number Legend and Standard Models

Model Number Legend

Models with Screw Terminals
E5DC-@@ @ @ S M-@@@ (Example: E5DC-RX0ASM-015)

           -- - - - - ---
             A BC DE F

Model      A          B                C         D                      E             F                              Meaning
E5DC                                                                               Options
        Control     No. of           Power    Terminal                 Input
        output 1   auxiliary         supply      type                  type
                   outputs           voltage

                                                                                                    22.5 mm wide and mounts to DIN Track

                                                                                            Control output 1                         Control output 2

        RX                                                                                       Relay output                             None

        QX                                                                                        Voltage output                          None
                                                                                                 (for driving SSR)
        CX
                       0                                                                    Linear current output *5                      None
                       2
                                      A                                                                               None
                                      D
                                                     S                                                              2 (one common)
                                                                    M
                                                                                                                    100 to 240 VAC

                                                                                                                    24 VAC/DC

                                                                                                                    Screw terminals

                                                                                                                    Universal input

                                                                                            HB alarm and HS alarm Communications Event input

                                                                              *1 000                ---                              ---        ---
                                                                              *2 002
                                                                              *3 015                1                          RS-485           ---
                                                                              *4 016
                                                                              *2 017                ---                        RS-485           ---

                                                                                                    ---                              ---               1

                                                                                                    1                                ---               1

*1 Option 000 can be selected only if two auxiliary outputs are selected.
*2 Options 002 and 017 can be selected only if the control output is a relay output or voltage output and two auxiliary outputs are selected.
*3 Option 015 cannot be selected if the control output is a relay output or voltage output and two auxiliary outputs are selected.
*4 Options 016 can be selected only if the control output is a linear current output and two auxiliary outputs are selected.
*5 The control output cannot be used as a transfer output.

List of Models

                                                                       Options                                      Model                       Model

Control output     No. of auxiliary  HB alarm and HS        No. of event inputs Communications           Power supply voltage        Power supply voltage
                        outputs              alarm
                                                                                                             100 to 240 VAC                 24 VAC/DC
                   ---                                                                      RS-485
                                                ---                                                       E5DC-RX0ASM-015             E5DC-RX0DSM-015
                                                                              ---           ---           E5DC-RX2ASM-000             E5DC-RX2DSM-000
Relay output                                                                                              E5DC-RX2ASM-002             E5DC-RX2DSM-002
                   2                                                                        RS-485        E5DC-RX2ASM-017             E5DC-RX2DSM-017
                                     Detection for single-                                                E5DC-QX0ASM-015             E5DC-QX0DSM-015
                                                                                                          E5DC-QX2ASM-000             E5DC-QX2DSM-000
                                     phase heater                             1             ---           E5DC-QX2ASM-002             E5DC-QX2DSM-002
                                                                                                          E5DC-QX2ASM-017             E5DC-QX2DSM-017
                   ---                                                                      RS-485        E5DC-CX0ASM-015             E5DC-CX0DSM-015
                                                ---                                                       E5DC-CX2ASM-000             E5DC-CX2DSM-000
                                                                              ---           ---           E5DC-CX2ASM-015             E5DC-CX2DSM-015
Voltage output                                                                                            E5DC-CX2ASM-016             E5DC-CX2DSM-016

(for driving SSR)  2                 Detection for single-                                  RS-485

                                     phase heater                             1             ---

                   ---                                                                      RS-485

Linear current                                ---                             ---           ---

output             2                                                                        RS-485

                                                                              1             ---

Note: These products are sold as a set with a terminal block (i.e., Terminal Unit).

Heating and Cooling Control

Using Heating and Cooling Control

A Control Output Assignment
An auxiliary output is used as the cooling control output.
B Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.

                                                                                                                                                           51
E5DC

Optional Products (Order Separately)                                 End Plate  Model
                                                                     Spacer     PFP-M
USB-Serial Conversion Cable
                                                                                Model
                      Model                                                     PFP-S
                   E58-CIFQ2

Communications Conversion Cable

                      Model                                          DIN Tracks

                 E58-CIFQ2-E                                                               Model
                                                                                         PFP-100N
Note: Always use this product together with the E58-CIFQ2.                               PFP-50N
        This Cable is used to connect to the front-panel Setup Tool
        port.

Current Transformers (CTs)

    Hole diameter                Model                               Unit Labels
        5.8 mm                  E54-CT1
        12.0 mm                 E54-CT3                                                    Model
                                                                                          Y92S-L2
Mounting Adapter
                                                                     End Cover
                      Model
                Y92F-53 (2pcs)

Short Bars                                                                       Model
                                                                                Y92F-54
                      Model
              Y92S-P11 (4 pcs)

CX-Thermo Support Software

                      Model
                 EST2-2C-MV4

Note: CX-Thermo version 4.6 or higher is required for the E5DC.
        For the system requirements for the CX-Thermo, refer to
        information on the EST2-2C-MV4 on the OMRON website
        (www.ia.omron.com).

52
                                                        E5DC

Specifications

Ratings

Power supply voltage               A in model number: 100 to 240 VAC, 50/60 Hz
Operating voltage range            D in model number: 24 VAC, 50/60 Hz; 24 VDC
Power consumption
                                   85% to 110% of rated supply voltage
Sensor input
                                   4.9 VA max. at 100 to 240 VAC, and 2.8 VA max. at 24 VDC or 1.5 W max. at 24 VDC
Input impedance
                                   Temperature input
Control method                          Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
                                        Platinum resistance thermometer: Pt100 or JPt100
Control    Relay output                 Infrared temperature sensor (ES1B): 10 to 70C, 60 to 120C, 115 to 165C, or 140 to 260C
output
           Voltage output          Analog input
Auxiliary  (for driving SSR)            Current input: 4 to 20 mA or 0 to 20 mA
output     Linear current output        Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
           Number of outputs
                                   Current input: 150  max., Voltage input: 1 M min. (Use a 1:1 connection when connecting the ES2-HB/
           Output specifications   THB.)

Event      Number of inputs        ON/OFF control or 2-PID control (with auto-tuning)
input
           External contact input  SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5
           specifications          V, 10 mA (reference value)

Setting method                     Output voltage 12 VDC 20% (PNP), max. Load current: 21 mA, with short-circuit protection circuit
Indication method
                                   4 to 20 mA DC/0 to 20 mA DC, load: 500  max., resolution: Approx. 10,000
Multi SP                           2 (depends on model)
Bank switching
                                   SPST-NO relay outputs: 250 VAC, 2 A (resistive load),
Other functions                    Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value)

Ambient operating temperature      1 (depends on model)
                                   Contact input ON: 1 k max., OFF: 100 k min.
Ambient operating humidity         Non-contact input ON: Residual voltage 1.5 V max.; OFF: Leakage current 0.1 mA max.
Storage temperature
Altitude                           Current flow: approx. 7 mA per contact
Recommended fuse
Installation environment           Digital setting using front panel keys

                                   11-segment digital displays and individual indicators
                                   Character height: PV: 8.5 mm, SV: 8.0 mm

                                   Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or
                                   serial communications.*

                                   None

                                   Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burn-
                                   out (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self
                                   tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change
                                   rate limit, logic operations, temperature status display, simple programming, moving average of input val-
                                   ue, and display brightness setting
                                   -10 to 55C (with no condensation or icing), For 3-year warranty: -10 to 50C with standard mounting (with
                                   no condensation or icing)

                                   25% to 85%
                                   -25 to 65C (with no condensation or icing)
                                   2,000 m max.

                                   T2A, 250 VAC, time-lag, low-breaking capacity

                                   Installation Category II, Pollution Degree 2 (IEC 61010-1 compliant)

* Only two set points are selectable for event inputs.

                                                                                                                                                53
E5DC

Input Ranges

Thermocouple/Platinum Resistance Thermometer (Universal inputs)

     Sensor                                  Platinum resistance                                                         Thermocouple                                                          Infrared temperature
       type                                       thermometer                                                                                                                                           sensor

     Sensor                                       Pt100            JPt100               K            J          T        EL                    U          N       R     S     B     W    PLII  10 to 60 to 115 to 140 to
    specifica-                                                                                                                                                                                 70C 120C 165C 260C
                                                                                                850                                                              1700  1700  1800  2300  1300
        tion         Temperature range (C)                                     1300                     400.0                                            1300
                                                                                                                                                                   0     0   100     0     0
                 2300                        850                                                -100 -20.0                               850
                 1800                                                                                                                                            16    17    18    19    20
                 1700                             500.0          500.0                  500.0    78                                 600
                 1600                                                                                           400 400.0
                 1500                                                                                                                          400 400.0
                 1400
                 1300                                     100.0          100.0                                                                                                                                               260
                 1200                                                                                                                                                                                   120 165
                 1100                                                                                                                                                                          90
                 1000
                                                          0.0            0.0                                                                                                                   0  0  0  0
                  900
                  800                                                                    -20.0                                           -100
                  700                                                           -200
                  600                        -200 -199.9         -199.9                                         -200 -199.9 -200               -200 -199.9 -200
                  500                                                            56
                  400                        01234                                                              9 10 11 12 13 14 15                                                            21 22 23 24
                  300
                  200
                  100

                 -100
                 -200

    Set value

                                             Shaded settings are the default settings.

The applicable standards for the input types are as follows:                                        JPt100: JIS C 1604-1989, JIS C 1606-1989
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 60584-1                                                Pt100: JIS C 1604-1997, IEC 60751
L: Fe-CuNi, DIN 43710-1985                                                                          PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)
U: Cu-CuNi, DIN 43710-1985
W: W5Re/W26Re, ASTM E988-1990

Analog input

          Input type                                               Current                                      Voltage
    Input specification
                                                          4 to 20 mA 0 to 20 mA 1 to 5 V 0 to 5 V                        0 to 10 V
    Setting range                                                                                                            29
                                                          Usable in the following ranges by scaling:
    Set value                                             -1999 to 9999, -199.9 to 999.9,
                                                          -19.99 to 99.99 or -1.999 to 9.999

                                                               25               26              27              28

54
                                                                                                                                                  E5DC

Alarm Types

Each alarm can be independently set to one of the following 17 alarm types. The default is 2: Upper limit. (See note.)
Auxiliary outputs are allocated to alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not

        displayed.
        To use alarm 1, set the output assignment to alarm 1.

Set                                                     Alarm output operation
value
               Alarm type              When alarm value X When alarm value X                                     Description of function

                                            is positive                       is negative

0 Alarm function OFF                                              Output OFF                   No alarm

                                       ON                LH                                    Set the upward deviation in the set point for the alarm upper
                                       OFF                                                     limit (H) and the lower deviation in the set point for the alarm
1          Upper- and lower-limit *1                              PV *2                        lower limit (L). The alarm is ON when the PV is outside this
                                                                                               deviation range.
                                                         SP

    2                                  ON                      X         ON   X                  Set the upward deviation in the set point by setting the alarm
(default)                              OFF                                                 PV value (X). The alarm is ON when the PV is higher than the
           Upper-limit                                            PV     OFF

                                                         SP                   SP               SP by the deviation or more.

                                       ON                X               ON         X          Set the downward deviation in the set point by setting the

3 Lower-limit                          OFF                        PV     OFF               PV alarm value (X). The alarm is ON when the PV is lower than
                                                           SP
                                                                              SP               the SP by the deviation or more.

           Upper- and lower-limit      ON                LH                                    Set the upward deviation in the set point for the alarm upper
           range *1                    OFF                                                     limit (H) and the lower deviation in the set point for the alarm
4                                                                 PV *3                        lower limit (L). The alarm is ON when the PV is inside this de-
                                                                                               viation range.
                                                         SP

5          Upper- and lower-limit      ON                LH       PV *4                        A standby sequence is added to the upper- and lower-limit
                                                          SP                                   alarm (1). *6
           with standby sequence *1 *5 OFF

           Upper-limit with standby    ON                      X         ON   X
           sequence                    OFF
6                                                                 PV     OFF               PV A standby sequence is added to the upper-limit alarm (2). *6

                                                         SP                   SP

7          Lower-limit with standby    ON                X               ON       X
           sequence                    OFF                SP
                                                                  PV     OFF            PV A standby sequence is added to the lower-limit alarm (3). *6

                                                                              SP

           Absolute-value upper-lim- ON                     X            ON      X             The alarm will turn ON if the process value is larger than the

8          it                          OFF                        PV     OFF           0 PV alarm value (X) regardless of the set point.
                                                      0

                                       ON                   X            ON      X             The alarm will turn ON if the process value is smaller than the
                                       OFF
9          Absolute-value lower-limit                             PV     OFF           0 PV alarm value (X) regardless of the set point.

                                            0

           Absolute-value upper-lim- ON                     X            ON      X             A standby sequence is added to the absolute-value upper-

10         it with standby sequence OFF 0                         PV     OFF           0 PV limit alarm (8). *6

           Absolute-value lower-limit ON                    X            ON      X             A standby sequence is added to the absolute-value lower-

11         with standby sequence       OFF                        PV     OFF           0 PV limit alarm (9). *6
                                                      0

12 LBA (alarm 1 type only)                                            -                        *7

13 PV change rate alarm                                               -                        *8

           SP absolute-value           ON        X                       ON      X             This alarm type turns ON the alarm when the set point (SP)
           upper-limit alarm           OFF  0
14                                                                SP     OFF           0 SP is higher than the alarm value (X).

           SP absolute-value           ON        X                       ON      X             This alarm type turns ON the alarm when the set point (SP)
           lower-limit alarm           OFF  0
15                                                                SP     OFF           0 SP is lower than the alarm value (X).

                                       Standard Control Standard Control

                                       ON                   X            ON      X

                                       OFF                        MV     OFF               MV
                                                      0
           MV absolute-value                                                           0       This alarm type turns ON the alarm when the manipulated
           upper-limit alarm *9
16                                     Heating/Cooling                   Heating/Cooling       variable (MV) is higher than the alarm value (X).

                                       Control (Heating MV) Control (Heating MV)

                                       ON                   X

                                       OFF                        MV Always ON
                                                      0

                                       Standard Control Standard Control

                                       ON                   X            ON      X

                                       OFF  0                     MV     OFF           0   MV

17         MV absolute-value           Heating/Cooling                   Heating/Cooling       This alarm type turns ON the alarm when the manipulated
           lower-limit alarm *9        Control (Cooling MV)              Control (Cooling MV)  variable (MV) is lower than the alarm value (X).

                                       ON                   X

                                       OFF                        MV Always ON
                                                      0

                                                                                                                                                                 55
E5DC

*1 With set values 1, 4, and 5, the upper- and lower-limit values can  *4 Set value: 5, Upper- and lower-limit with standby sequence
     be set independently for each alarm type, and are expressed as         For Upper- and Lower-Limit Alarm Described Above at *2
     "L" and "H."                                                            In cases 1 and 2 above, the alarm is always OFF if the upper-

*2 Set value: 1, Upper- and lower-limit alarm                                   and lower-limit hysteresis overlaps.

    Case 1     Case 2        Case 3 (Always OFF)                            In case 3, the alarm is always OFF.

    L H SP     SP L H          H SP L              H<0, L<0            *5 Set value: 5, Upper- and lower-limit alarm with standby sequence
                             H L SP                                         The alarm is always OFF if upper- and lower-limit hysteresis
    H<0, L>0    H>0, L<0                          H<0, L>0                  overlaps.
    |H| < |L|    |H| > |L|                         |H|  |L|
                                                   H>0, L<0            *6 Refer to the E5@C Digital Temperature Controllers User's Manual
                             SP H L                 |H|  |L|                (Cat. No. H174) for information on the operation of the standby
                                                                            sequence.
*3 Set value: 4, Upper- and lower-limit range     H<0, L<0
                                                  H<0, L>0             *7 Refer to the E5@C Digital Temperature Controllers User's Manual
    Case 1     Case 2        Case 3 (Always ON)    |H|  |L|                 (Cat. No. H174) for information on the LBA.
                                                  H>0, L<0
     L H SP    SP L H          H SP L              |H|  |L|            *8 Refer to the E5@C Digital Temperature Controllers User's Manual
                             H L SP                                         (Cat. No. H174) for information on the PV change rate alarm.
    H<0, L>0     H>0, L<0
    |H| < |L|     |H| > |L|                                            *9 When heating/cooling control is performed, the MV absolute-
                                                                            value upper-limit alarm functions only for the heating operation
                             SP H L                                         and the MV absolute-value lower-limit alarm functions only for the
                                                                            cooling operation.

56
                                                                                                                                E5DC

Characteristics

Indication accuracy                 Thermocouple: (0.3 % of indication value or 1C, whichever is greater) 1 digit max.*1
(when mounted individually, ambi-
ent temperature of 23C)            Platinum resistance thermometer: (0.2 % of indication value or 0.8C, whichever is greater) 1 digit max.

                                    Analog input:    0.2% FS 1 digit max.

                                    CT input:        5% FS 1 digit max.

Influence of temperature *2         Thermocouple input (R, S, B, W, PL II): (1% of indication value or 10C, whichever is greater) 1 digit
Influence of voltage *2             max.
                                    Other thermocouple input: (1% of indication value or 4C, whichever is greater) 1 digit max. *3
                                    Platinum resistance thermometer: (1% of indication value or 2C, whichever is greater) 1 digit max.
                                    Analog input: 1% FS 1 digit max.
                                    CT input: 5% FS 1 digit max.

Installation influence (E5DC only)  R, S, B, W, or PLII thermocouple: (1% of PV or 10C, whichever is greater) 1 digit max.
                                    Other thermocouple: (1% of PV or 4C, whichever is greater) 1 digit max. *3

Input sampling period               50 ms

Hysteresis                          Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                    Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

Proportional band (P)               Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                    Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I)                   0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D)                 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Proportional band (P) for cooling   Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                    Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I) for cooling       0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D) for cooling     0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Control period                      0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)

Manual reset value                  0.0% to 100.0% (in units of 0.1%)

Alarm setting range                 -1,999 to 9,999 (decimal point position depends on input type)

Influence of signal source resis-   Thermocouple: 0.1C/ max. (100  max.), Platinum resistance thermometer: 0.1C/ max. (10  max.)
tance

Insulation resistance               20 M min. (at 500 VDC)

Dielectric strength                 3,000 VAC, 50/60 Hz for 1 min between terminals of different charge

                 Malfunction        10 to 55 Hz, 20 m/s2 for 10 min each in X, Y and Z directions
Vibration                           10 to 55 Hz, 20 m/s2 for 2 hr each in X, Y, and Z directions

                 Resistance

Shock       Malfunction             100 m/s2, 3 times each in X, Y, and Z directions
            Resistance              300 m/s2, 3 times each in X, Y, and Z directions

Weight                              Controller: Approx. 120 g

Degree of protection                Main unit: IP20, Terminal unit: IP00

Memory protection                   Non-volatile memory (number of writes: 1,000,000 times)

Setup Tool                          CX-Thermo version 4.6 or higher

Setup Tool port                     E5DC bottom panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect a USB port on the
                                    computer. *5
                                    E5DC front panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion Cable are
                                    used together to connect a USB port on the computer.*5

                 Approved standards UL 61010-1, Korean Radio Waves Act (Act 10564)
Standards

                 Conformed standards EN 61010-1 (IEC 61010-1): Pollution Degree 2 , overvoltage category II

                                    EMI:                                              EN61326

                                    Radiated Interference Electromagnetic Field Strength: EN55011 Group 1, class A

                                    Noise Terminal Voltage:                           EN55011 Group 1, class A

                                    EMS:                                              EN61326

EMC                                 ESD Immunity:                                     EN61000-4-2

                                    Electromagnetic Field Immunity:                   EN61000-4-3

                                    Burst Noise Immunity:                             EN61000-4-4

                                    Conducted Disturbance Immunity:                   EN61000-4-6

                                    Surge Immunity:                                   EN61000-4-5

                                    Voltage Dip/Interrupting Immunity:                EN61000-4-11

*1 The indication accuracy of K thermocouples in the -200 to 1,300C range, T and N thermocouples at a temperature of -100C max., and U
     and L thermocouples at any temperature is 2C 1 digit max. The indication accuracy of B thermocouples at a temperature of 400C max. is
     not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800C is 3C max.
     The indication accuracy of R and S thermocouples at a temperature of 200C max. is 3C 1 digit max. The indication accuracy of W
     thermocouples is (0.3% of PV or 3C, whichever is greater) 1 digit max.
     The indication accuracy of PLII thermocouples is (0.3% of PV or 2C, whichever is greater) 1 digit max.

*2 Ambient temperature: -10C to 23C to 55C, Voltage range: -15% to 10% of rated voltage
*3 K thermocouple at -100C max.: 10C max.
*4 The unit is determined by the setting of the Integral/Derivative Time Unit parameter.

*5 External serial communications (RS-485) and USB-Serial Conversion Cable communications can be used at the same time.

                                                                                                                                               57
E5DC

USB-Serial Conversion Cable                                                                                           When Digital Temperature Controllers are connected, set
                                                                                                                      points and RUN/STOP commands can be sent from the Digi-
    Applicable OS           Windows XP/Vista/7/8                                  Component                           tal Temperature Controller that is set as the master to the Dig-
    Applicable software     CX-Thermo version 4.6 or higher                                                           ital Temperature Controllers that are set as slaves.
    Applicable models       E5@C-T Series, E5@C Series, and E5CB Series           Communica-                          Slope and offsets can be set for the set point.
    USB interface standard  Conforms to USB Specification 2.0                     tions*1                             Number of connected Digital Temperature Controllers: 32
                                                                                                                      max. (including master)

    DTE speed               38,400 bps                                            Copying*2                           When Digital Temperature Controllers are connected, the pa-
                            Computer: USB (Type A plug)                                                               rameters can be copied from the Digital Temperature Control-
    Connector               Digital Temperature Controller: Special serial con-                                       ler that is set as the master to the Digital Temperature
    specifications          nector                                                                                    Controllers that are set as slaves.
                            Bus power (Supplied from the USB host controller) *
    Power supply            5 VDC                                                 MELSEC is a registered trademark of Mitsubishi Electric Corporation.
    Power supply voltage    450 mA max.
    Current consumption     4.70.2 VDC (Supplied from USB-Serial Conver-         KEYENCE is a registered trademark of Keyence Corporation.
                            sion Cable to the Digital Temperature Controller.)
    Output voltage          250 mA max. (Supplied from USB-Serial Conver-         *1 A Temperature Controller with version 2.1 or higher is required for
                            sion Cable to the Digital Temperature Controller.)         the FX Series or the KV Series.
    Output current
                            0 to 55C (with no condensation or icing)             *2 Both the programless communications and the component
    Ambient operating                                                                  communications support the copying.
    temperature             10% to 80%
    Ambient operating                                                             Current Transformer (Order Separately)
    humidity                -20 to 60C (with no condensation or icing)           Ratings
    Storage temperature     10% to 80%
    Storage humidity        2,000 m max.                                          Dielectric strength                                   1,000 VAC for 1 min
    Altitude                Approx. 120 g                                         Vibration resistance
    Weight                                                                        Weight                                                50 Hz, 98 m/s2

                                                                                  Accessories (E54-CT3 only)                            E54-CT1: Approx. 11.5 g,
                                                                                                                                        E54-CT3: Approx. 50 g

                                                                                                                                        Armatures (2)
                                                                                                                                        Plugs (2)

Windows is a registered trademark of Microsoft Corporation in the                 Heater Burnout Alarms and SSR Failure
                                                                                  Alarms
United States and or other countries.
                                                                                  CT input (for heater current Models with detection for single-phase heat-
* Use a high-power port for the USB port.
                                                                                  detection)                                            ers: One input
Note: A driver must be installed on the computer. Refer to the
        Instruction Manual included with the Cable for the installation
        procedure.

                                                                                  Maximum heater current                                50 A AC

Communications Specifications                                                     Input current                                         5% FS 1 digit max.
                                                                                  indication accuracy

    Transmission line connection  RS-485: Multidrop                               Heater burnout alarm                                  0.1 to 49.9 A (in units of 0.1 A)
    method                                                                        setting range *1                                      Minimum detection ON time: 100 ms *3

    Communications                RS-485 (two-wire, half duplex)                  SSR failure alarm setting                             0.1 to 49.9 A (in units of 0.1 A)
                                                                                  range *2                                              Minimum detection OFF time: 100 ms *4
    Synchronization method        Start-stop synchronization

    Protocol                      CompoWay/F, or Modbus                           *1 For heater burnout alarms, the heater current will be measured when the
                                                                                       control output is ON, and the output will turn ON if the heater current is
    Baud rate*                    9,600, 19,200, 38,400, or 57,600 bps                 lower than the set value (i.e., heater burnout detection current value).

    Transmission code             ASCII                                           *2 For SSR failure alarms, the heater current will be measured when the
                                                                                        control output is OFF, and the output will turn ON if the heater current is
    Data bit length *             7 or 8 bits                                           higher than the set value (i.e., SSR failure detection current value).

    Stop bit length *             1 or 2 bits                                     *3 The value is 30 ms for a control period of 0.1 s or 0.2 s.
                                                                                  *4 The value is 35 ms for a control period of 0.1 s or 0.2 s.
                                  Vertical parity (none, even, odd)
    Error detection               Block check character (BCC)                     Electrical Life Expectancy Curve for
                                  with CompoWay/F or                              Control Output Relay (Reference Values)
                                  CRC-16 with Modbus

    Flow control                  None

    Interface                     RS-485                                          Life ( 104 operations)  500
                                                                                                           300
    Retry function                None

    Communications buffer         217 bytes

    Communications response       0 to 99 ms                                                               100
    wait time                     Default: 20 ms
                                                                                                            50
* The baud rate, data bit length, stop bit length, and vertical parity can                                  30
  be individually set using the Communications Setting Level.

Communications Functions

                    You can use the memory in the PLC to read and write E5@C                               10
                    parameters, start and stop operation, etc.
                    The E5@C automatically performs communications with                                    5       E5DC
                    PLCs. No communications programming is required.
                    Number of connected Digital Temperature Controllers: 32                                3       250 VAC, 30 VDC
                    max. (Up to 16 for the FX Series)
    Programless     Applicable PLCs: OMRON PLCs                                                                    (resistive load)

    communica-                 CS Series, CJ Series, or CP Series                                                  cos = 1
    tions *1            Mitsubishi Electric PLCs
                                                                                                           1
                               MELSEC Q Series, L Series, or FX Series (compati-
                               ble with the FX2 or FX3 (excluding the FX1S))                                    0  1        2        3  4        5      6
                        KEYENCE PLCs
                               KEYENCE KV Series                                                                                        Switching current (A)

58
                                                                                                                                                  E5DC

External Connections

E5DC                                     Auxiliary outputs 1, 2       The E5DC is set for a K-type thermocouple (input type = 5) by default.
                                                                      An input error (s.err) will occur if the input type setting does not agree
           Control output          Relay outputs                      with the temperature sensor. Check the input ty