E5CB-R1P-AC100-240

器件型号:E5CB-R1P-AC100-240
器件类别:机电产品    工业自动化   
文件大小:15768.14KB,共10页
厂商名称:OMRON
厂商官网:https://www.omron.com
下载文档

器件描述

Solid State Relays - Industrial Mount 0.15-25A 3-32VDC

参数

产品属性属性值
产品种类:
Product Category:
Controllers
制造商:
Manufacturer:
Omron
RoHS:No
Analog / Digital:Digital
类型:
Type:
Temperature Controller
Display Type:7-Segment, 4 Digit
工作电源电压:
Operating Supply Voltage:
100 VAC to 240 VAC
Mounting:Panel
大小:
Size:
48 mm x 48 mm
商标:
Brand:
Omron Automation and Safety
Features:Improved visibility with character height of approximate 16 mm
输出类型:
Output Type:
Relay
工厂包装数量:
Factory Pack Quantity:
1
单位重量:
Unit Weight:
3.527396 oz

E5CB-R1P-AC100-240器件文档内容

Temperature Controller

E5CB (48 × 48 mm)

Ideal for heater control, these

Temperature Controllers offer the

highest control performance at

surprisingly low cost!

Easy to Read with One of the Largest

Character Displays Anywhere.

• Improved visibility with character height of approx. 16 mm.

• Depth beyond front panel: Only 60 mm.                                                                48 × 48 mm

• Fewer parameters for simple setup.

• Faster sampling at 250 ms.                                                   For the most recent information on models that have been certified for

• High reliability with a three-year warranty.                                 safety standards, refer to your OMRON website.

                                                                                      Refer to Safety Precautions on page 9.

Main I/O Functions

                                                 E5CB

                                                                 Dual Display         4-digit Display

Sensor Inputs

• Thermocouple inputs                                            Alarm Outputs

• Pt inputs                                                                    • One

Indication Accuracy

• Thermocouple input: ±0.5%    of  PV

• Pt input: ±0.5% of PV                          Control Output

                                                 • Relay output

Sampling Period                                  • Voltage output (for driving SSR)

• 250 ms

Model Number Structure

Model Number Legend

E5CB-@1@@

          1  2  3  4

1. Control Output

R: Relay output: 250 VAC, 3 A

Q: Voltage output (for driving SSR): 12 VDC, 21  mA

2. Alarm

1: Relay output: 250 VAC, 1 A (resistive load)

3. Sensor type

TC: Thermocouple (K, J, T, R, or S)

P: Platinum resistance thermometer (Pt100)

4. Power Supply Voltage

Blank:    100 to 240 VAC

D:        24 VAC/VDC

                                                                                                                                                       1
   E5CB

   Ordering Information

   Temperature Controllers

         Size         Power supply voltage              Input type                   Alarm output   Control output                              Model

                                                Thermocouple                                        Relay output                  E5CB-R1TC

                     100 to 240 VAC             Platinum resistance thermometer                                                   E5CB-R1P

                                                Thermocouple                                        Voltage output                E5CB-Q1TC

   E5CB                                         Platinum resistance thermometer   1                 (for driving SSR)             E5CB-Q1P

   48 × 48 mm                                   Thermocouple                                        Relay output                  E5CB-R1TCD

                     24 VAC/VDC                 Platinum resistance thermometer                                                   E5CB-R1PD

                                                Thermocouple                                        Voltage output                E5CB-Q1TCD

                                                Platinum resistance thermometer                     (for driving SSR)             E5CB-Q1PD

   Accessories (Order Separately)

   Terminal Cover                                                            Adapter

   Model                             E53-COV19                                    Model                                 Y92F-45

   Note: If you use the E53-COV19 Terminal Cover, you will not be able       Note: 1.         Use this Adapter when the Front Panel has already been

   to connect two crimp terminals to the same terminal on the                                 prepared for the E5B@.

   terminal block.                                                                        2.  Only black is available.

   Front Cover                                                               Watertight Cover

                 Type                            Model                            Model                                 Y92A-48N

   Hard Front Cover                  Y92A-48B                                DIN Track Mounting     Adapter

   Soft Front Cover                  Y92A-48D

   USB-Serial Conversion Cable                                                    Model                                 Y92F-52

   Model                             E58-CIFQ2                               Waterproof Packing     (Included)

   Mounting Adapter (Included)                                                    Model                                 Y92S-P6

   Model                             Y92F-49                                 Unit Seal

                                                                                  Model                                 Y92S-L2

   Specifications

   Ratings

   Power supply voltage              100 to 240 VAC 50/60 Hz, 24 VAC 50/60 Hz, or 24 VDC

   Operating voltage range           85% to 110% of rated supply voltage

                                     Approx. 3.5 VA (100 to 240 VAC)

   Power consumption                 Approx. 3.5 VA (24 VAC)

                                     Approx. 2.5 W (24 VDC)

                                     Models with thermocouple inputs

   Sensor input                      Thermocouple: K, J, T, R, or S (JIS C 1602-1995, IEC60584-1)

                                     Models with platinum resistance thermometer inputs

                                     Platinum resistance thermometer: Pt100 (JIS C 1604-1997, IEC60751)

                     Relay output    SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations,

   Control                           minimum applicable load: 5 V, 10 mA

   output            Voltage output

                     (for driving    Output voltage: 12 VDC +25%/−15% (PNP), max. load current: 21 mA, with short-circuit protection circuit

                     SSR)

   Alarm output      Relay output    SPST-NO, 250 VAC, 1 A (resistive load), electrical life: 100,000 operations, minimum         load:  5  V,  10  mA

   Control method                    ON/OFF control or 2-PID control (with auto-tuning)

   Setting method                    Digital setting using front panel keys

   Indication method                 7-segment digital display and individual indicators

                                     Character height: 16.2 mm (PV)

   Other functions                   Temperature input shift, run/stop, protection functions, etc.

   Ambient operating                 −10 to 55°C (with no condensation or icing)/With a three-year guarantee: −10 to 50°C

   temperature

   Ambient operating humidity        25% to 85%

   Storage temperature               −25 to 65°C (with no condensation or icing)

2
                                                                                                                                                                           E5CB

Input Ranges

Models with Thermocouple Inputs

Model                                               Set value             Input type  Range

(temperature input)                                                                   °C                           °F

                                                    0                     K           −200 to 1,300                −300 to 2,300

                                                    1                                 −20.0 to 500.0               0.0 to 900.0

                                                    2                     J           −100 to 850                  −100 to 1500

TC input                                            3                                 −20.0 to 400.0               0.0 to 750.0

                                                    4                     T           −200 to 400                  −300 to 700

                                                    5                                 −199.9 to 400.0              −199.9 to 700.0

                                                    6                     R           0 to 1,700                   0 to 3,000

                                                    7                     S           0 to 1,700                   0 to 3,000

Default setting: 0

Applicable standards  (K,                   J,  T,  R, S): JIS C1602-1995             and IEC 60584-1

Platinum Resistance Thermometer Input

Model                                               Set value             Input type  Range

(temperature input)                                                                   °C                           °F

Pt input                                            8                     Pt100       −200 to 850                  −300 to 1500

                                                    9                                 −199.9 to 500.0              −199.9 to 900.0

Default setting: 8

Applicable standards (Pt100): JIS C1604-1997 and IEC 60751

Alarm Types

Select alarm types out of the 11 alarm types listed in the following table.

    Setting                                 Alarm type                       Positive alarm value             (X)      Negative alarm value     (X)  Deviation alarm/absolute value alarm

0                 No alarm                                                   Output OFF

                                                                                 ON             X     X

1                 Upper/lower limit                                              OFF                                   Always ON                     Deviation alarm

                                                                                                SP

                                                                                 ON                   X                ON           X

2                 Upper limit                                                    OFF                                   OFF                           Deviation alarm

                                                                                                SP                                  SP

                                                                                 ON             X                      ON                 X

3                 Lower limit                                                    OFF                                   OFF                           Deviation alarm

                                                                                                SP                                  SP

                                                                                 ON             X     X

4                 Upper/lower range                                              OFF                                   Always OFF                    Deviation alarm

                                                                                                SP

5                 Upper/lower limit standby                                      ON             X     X                Always OFF                    Deviation alarm

(See  note   2.)  sequence ON                                                    OFF            SP

6                 Upper limit standby sequence                                   ON                   X                ON           X

(See  note   2.)  ON                                                             OFF                                   OFF                           Deviation alarm

                                                                                                SP                                  SP

7                 Lower limit standby sequence                                   ON             X                      ON                 X

(See  note   2.)  ON                                                             OFF                                   OFF                           Deviation alarm

                                                                                                SP                                  SP

                                                                                 ON                X                   ON              X

8                 Absolute value upper limit                                     OFF                                   OFF                           Absolute value alarm

                                                                                          0                                                  0

                                                                                 ON                X                   ON              X

9                 Absolute value lower limit                                     OFF                                   OFF                           Absolute value alarm

                                                                                          0                                                  0

10                Absolute value upper limit                                     ON                X                   ON              X

(See note 2.)     standby sequence ON                                            OFF                                   OFF                           Absolute value alarm

                                                                                          0                                                  0

11                Absolute value lower limit                                     ON                X                   ON              X

(See note 2.)     standby sequence ON                                            OFF                                   OFF                           Absolute value alarm

                                                                                          0                                                  0

12                Do not set.

Note: 1.   The default is 2.                                                                                           The standby sequence is started again when any of the following

       2.  Alarms with a Standby Sequence                                                                              conditions is met.

           The alarm is blocked until the first safe-state is reached.                                                 • Operation is started (power is turned ON or operation is switched

           Unwanted alarm during start-up are prevented.

Example: Deviation Lower Limit Standby Sequence ON                                                                     from stop to run).

The standby sequence is cleared when the alarm OFF condition has                                                       • The alarm value is changed.

been met.                                                                                                              • The temperature input offset is changed.

                                                                                                                       • The set point is changed.

                                                                                          Alarm hysteresis

                      Alarm value                                                         (always 0.2 °C/°F)

                                                       Process value

                                                                                          Time

                                                Standby sequence cleared

               Alarm with standby sequence

               Alarm without standby sequence

                                                                                                                                                                                            3
   E5CB

   Characteristics

                                                                                     Thermocouple: (See note 1.)
                                                                                             (±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit max.
   Indication accuracy                                                               Platinum resistance thermometer:

                                                                                             (±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit max.

   Influence of temperature (See note 2.)                                            R and S thermocouple inputs: (±1% of PV or ±10°C, whichever is greater) ±1 digit max.

   Influence of voltage (See note 2.)                                                K, J, and T thermocouple inputs: (±1% of PV or ±4°C, whichever is greater) ±1 digit max.
                                                                                     Platinum resistance thermometer inputs: (±1% of PV or ±2°C, whichever is greater) ±1 digit max.
   Influence of EMS. (at EN 61326-1)

   Hysteresis                                                                        0.1 to 999.9 (in units of 0.1) °C/°F

   Proportional band (P)                                                             0.1 to 999.9 (in units of 0.1) °C/°F

   Integral time (I)                                                                 0 to 3999 s (in units of 1 s)

   Derivative time (D)                                                               0 to 3999 s (in units of 1 s)

   Control period                                                                    0.5, 1 to 99 s (in units of 1 s)

   Alarm setting range                                                               −1999 to 9999 (decimal point position depends on input type)

   Input sampling period                                                             250 ms

   Affect of signal source resistance                                                Thermocouple: 0.1°C/Ω max. (100 Ω max.) (See note 3.)
                                                                                     Platinum resistance thermometer: 0.6°C/Ω max. (10 Ω max.)

   Insulation resistance                                                             20 MΩ min. (at 500 VDC)

   Dielectric strength                                                               2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge)

   Vibration resistance                                     Malfunction              10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions

                                                            Destruction              10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions

   Shock resistance                                         Malfunction              200 m/s2, 3 times each in X, Y, and Z directions

                                                            Destruction              300 m/s2, 3 times each in X, Y, and Z directions

   Weight                                                                            Controller: Approx. 100 g, Mounting Bracket: Approx. 10 g

   Degree of protection                                                              Front panel: IP66
                                                                                     Rear case: IP20, Terminals: IP00

   Memory protection                                                                 Non-volatile memory (number of writes: 100,000 times)

                                                            Certified standards      UL 61010-1, CSA C22.2 No. 1010-1

   Conformed standards                                      Applicable standards     EN61326, EN61010-1, IEC61010-1

                                                                                     VDE0106, Part 100 (Finger protection), when the terminal cover is mounted.

                                                                                     EMI                                         EN61326-1 (See note 4.)
                                                                                     Emission Enclosure:                         EN55011 Group1 Class A
                                                                                     Emission AC Mains:                          EN55011 Group1 Class A
                                                                                     EMS                                         EN61326-1 (See note 4.)
                                                                                     Immunity ESD:                               EN61000-4-2
   EMC                                                                               Immunity RF-interference:                   EN61000-4-3

                                                                                     Immunity Burst:                             EN61000-4-4
                                                                                     Conduction Disturbance Immunity             EN61000-4-6
                                                                                     Immunity Surge:                             EN61000-4-5
                                                                                     Immunity Voltage Dip/Interrupting:          EN61000-4-11

   Note: 1.                            The indication accuracy of K and T thermocouples at a temperature of −100°C max. is ±2°C ±1 digit maximum. The indication                                      accuracy

                                       of the R and S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max.

                                   2.  Conditions: Ambient temperature: −10 to 23 to 55°C, Voltage range: −15% to ±10% of rated voltage

                                   3.  R, and S sensors: 0.2°C/Ω max. (100 Ω max.)

                                   4.  Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)

   Electrical Life Expectancy Curve for                                                                                USB-Serial Conversion Cable

   Relays (Reference Values)                                                                                           Specifications

                              100                                                                                      Applicable OS                Windows XP/Vista/7/8

   No. of operations (x 104)  50                                                                                       Applicable software          Thermo Mini

                              30                                                                                       Applicable models            E5CB Series

                                                                                                                       USB interface standard       USB specification 1.1

                                                                                                                       DTE speed                    38,400 bps

                              10       E5CB                                                                                                         Computer: USB (Type A plug)

                                       250 VAC, 30 VDC                                                                 Connector Specifications     Temperature Controller: Special serial connector

                              5        (resistive load)

                                                                                                                       Power supply                 Bus power (supplied from the USB host controller)

                              3                                                                                        Power supply voltage         5 VDC

                                                                                                                       Current consumption          450 mA max.

                              1                                                                                        Output voltage               4.7±0.2 VDC (Supplied from USB-Serial Conversion Cable

                                   0   1                 2  3                4    5                                                                 to the Temperature Controller.)

                                                            Contact current  (A)                                                                    250 mA max. (Supplied from USB-Serial Conversion Cable

                                                                                                                       Output current               to the Temperature Controller.)

                                                                                                                       Ambient temperature          0 to 55°C (with no condensation or icing)

                                                                                                                       Ambient humidity             10% to 80%

                                                                                                                       Storage temperature          −20 to 60°C (with no condensation or icing)

                                                                                                                       Storage humidity             10% to 80%

                                                                                                                       Altitude                     2,000 m max.

                                                                                                                       Weight                       Approx. 120 g

                                                                                                                       Note:   1.  A high-power port is used for the USB port.
                                                                                                                               2.  A driver must be installed on the computer. Refer to the Instruction
                                                                                                                                   Manual included with the Cable for the installation procedure.

4
                                                                                                                                                                                                      E5CB

External Connections

• A voltage output (control output) is not electrically insulated from the internal circuits. When using a grounding thermocouple, do not connect

any of the control output terminals to ground. If the control output terminals are connected to ground, errors will occur in the measured

temperature values as a result of leakage current.

E5CB                                           Control Output

                                               • Relay output: 250 VAC, 3 A (resistive load)

                                               • Voltage output (for driving SSR): 12 VDC, 21 mA

                                                                 +             1

                                                            Control output

                                                                 −             2                                 7   Alarm Output

                                                   A                           3                                 8   • Relay output: 250 VAC, 1 A

                                                                    DO NOT                                                            (resistive load)

                                                                    USE

                                                   B                  −        4                                 9

                                                                                                                     Input power supply

                                                   B                  +        5                                 10          • 100 to 240 VAC, 50/60 Hz

                                                                                                                             • 24 VAC, 50/60 Hz

                                                   Pt input         TC input                                                 • 24 VDC(no polarity)

Nomenclature

E5CB

                                                                                                                             (1)

                                                                      (3)

                                                                      (4)                                                    (2)

                                                                      (5)

                                                                      (6)                                                    (8)

                                                                      (7)                                                    (9)

                                                                                        (10)      (11)

                                                                                                        (12)

(1)  Display  No.  1        Displays the process value (PV) or parameter.                         (10) O+            Press these keys for at least 3 seconds in Operation Level or Adjustment Level

(2)  Display  No.  2        Displays the set point (SP) or parameter setting.                                        to go to Protect Level.

                                                                                                                     Press these keys for at least 1 second in Protect Level to return to Operation Level.

(3)  ALM                    Lit while the alarm is ON. Not lit while the alarm is OFF.

(4)  OUT                    Lit while the control output is ON.                                   (11)        +      Press these keys for at least 2 seconds to start or stop autotuning.*1

                            Not lit while the control output is OFF.

(5)  STOP                   Not lit during operation. Lit while operation is stopped.             (12)        +      Press these keys for at least 2 seconds to start or stop operation.*2

(6)                         Level Key: Changes the setting level.                                 *1: These keys are disabled when starting and stopping autotuning has been disabled

(7)                         Mode Key: Changes the parameter within the setting level.                   with operation control key protection.

(8)                         Down Key: Reduces the setting.                                        *2: These keys are disabled when starting and stopping operation has been disabled

(9)                         Up Key: Increases the setting.                                              with operation control key protection.

Dimensions                                                                                                                                                                                           (Unit:  mm)

E5CB

                                                                                                                                            Panel    Cutout

                                5              65                                       44.8×44.8                    Individual Mounting                    Side-by-side Mounting

              48×48                            60                                                                                 45  +0.6              (48 × number of Controllers − 2.5)     +1.0

                            1.5                                                                                                       0                                                        0

                                                                                                                                                                                   45       +0.6

                                                                                                                                                                                            0

                                                                           58                                       60 min.                              •  Recommended panel thickness is 1 to 5 mm.

                                                                                                                                              45  +0.6   •  Do not vertically mount Controllers side by

                                                                                                                                                  0         side. (Allow mounting clearance between the

                                                                                                                                                            Controllers.)

                                                                                                                                                         •  To install the Controller so that it is waterproof,

                                                                                                                                                            insert the Waterproof Packing.

                                                                                                                                                         •  When two or more Controllers are mounted,

     Package Contents              Panel                                                                                                                    make sure that the surrounding temperature

      • Temperature Controller                                                • Solderless terminal size: M3.5                                              does not exceed the ambient operating

                                                   Adapter                    • Terminal Cover: E53-COV19                                                   temperature given in the specifications.

      • Mounting Adapter           Waterproof      (Y92F-49)                   (sold separately)                                                         •  Use a control panel thickness of 1 to 2.5 mm if

      • Instruction Manual         packing                                                                                                                  a USB-Serial Conversion Cable is used when

      • Waterproof packing         (Y92S-P6)                                  • USB-Serial Conversion Cable: E58-CIFQ2                                      mounting the Controller to a control panel.

                                                                               (sold separately)

      The Support Software port is on the top of the Temperature Controller.

      This port is used to connect the Temperature Controller to a personal computer.

      The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection.

      For details on connection methods, refer to the E58-CIFQ2 USB-Serial Conversion Cable Instruction Manual.

      *Do not leave the USB-Serial Conversion Cable connected while using the Temperature Controller.

                                                                                                                                                                                                                  5
   E5CB

   Accessories (Order     Separately)

   Terminal Cover                                                                    Waterproof Packing

   E53-COV19                                                                         Y92S-P6

                          43.3                      4                                         Order the Waterproof Packing separately if it becomes lost or damaged.

                                                    1.2                                       The Waterproof Packing can be used to achieve an IP66

                                                                                              degree of protection.

                                                                                              (Deterioration, shrinking, or hardening of the waterproof

                                                                                              packing may occur depending on the operating

                    43.8                                                                      environment. Therefore, periodic replacement is

                                                                                              recommended to ensure the level of waterproofing

                                                                                              specified in IP66. The time for periodic replacement

                                                                                              depends on the operating environment. Be sure to confirm

                                                                                              this point at your site. Consider one year a rough standard.

   Note: You cannot use the following Terminal Covers: E53-COV10                              OMRON shall not be liable for the level of water resistance

   and E53-COV17. If you use the E53-COV19 Terminal Cover,                                    if the customer does not perform periodic replacement.)

   you will not be able to connect two crimp terminals to the same                            The Waterproof Packing does not need to be attached if a

   terminal on the terminal block.                                                            waterproof structure is not required.

   Unit Labels                                      The Unit Labels for the      Digital Panel Meter are used.

   Y92S-L2                                          Use either the °C or °F      label from the sheet.

   USB-Serial   Conversion Cable

   E58-CIFQ2                                                                                           (2,109.1)

                                                                                                                   (13)                                 (5) (15)

                                                             250                              (87)                                            1,740

                                                                                              LED indicator (RD)                       (250)

                                         USB connector (Type A plug)

                                                                                                                   LED indicator (PWR)                  Serial connector

                                                                                                                   LED indicator (SD)

   Adapter      Note: 1.  Use this Adapter when the Front Panel has already been prepared                          Front Covers

                    2.    for the E5B@.                                                                            Front Covers are available.
                          Only black is available.
                                                                                                                   Use them in the following cases.
                    3.    You cannot use the E58-CIFQ2 USB-Serial Conversion Cable if you
                                                                                                                   • To protect the setting panel from dust and dirt
                          use the Y92F-45 Adapter. To use the USB-Serial Conversion Cable

                          to make the settings, do so before you mount the Temperature                             • To prevent inadvertently touching the setting

                          Controller in the panel.                                                                 panel and accidentally changing the settings

                    4.    You cannot use this Adapter together with the Y92F-49 Adapter that                       • To help protect the front panel from water drops

   Y92F-45                is provided with the E5CB Temperature Controller.                                        • To help protect the Temperature Controller

                                                                                              Fixture (Accessory)  from static electricity

                                                    4.7                          76

                                                                           69.6 to 77.6                                  Y92A-48B                    Y92A-48D

                          72 × 72                                                                                  (Hard Front Cover)                (Soft Front Cover)

                                                                                              67 × 67  87

   Mounted to E5CB                                                         Panel (1 to 8 mm)  Mounting Adapter

                          72 × 72                                                             Y92F-30 (Accessory)  Note: 1.  The Y92A-48B Front Cover is made

                                                                                                                             from hard plastic. It must be removed to

                                                                                                                             change the settings.

                                                                                                                             The Y92A-48D Front Cover is made

                                                                                                                             from PVC. You can press the front of the

                                                    48 × 48                                                                  Front Cover to change the settings.

                                                                                                                             However, the Front Cover makes it more

                                                                                                                             difficult to change the settings. Confirm

                                                                                                                             applicability in advance.

                                                                                                                         2.  The Soft Front Cover may deteriorate,

                                                                                                                             shrink, or harden due to the application

                                                                                                                             environment. We recommend replacing

                                                    2.2               4.7                                                    it periodically.

                                                                           62.8

                                                                      To back of the E5CB

6
                                                                                           E5CB

DIN Track Mounting Adapter

Y92F-52   Note: This Adapter cannot be used together with the Terminal  Cover.

                Remove the Terminal Cover to use the Adapter.

                                                                                      61

                                                                                      3.5

                                  50                                    38

Mounted to E5CB

                                                               48

                                                                                80.5

Watertight Cover

Y92A-48N

                            21.9      14

                            (2)

          87.7  79.2                      69

                                          12

                      67.6  28.9

                                                                                                 7
   E5CB

   Operating Procedure

   Parameters

   Depending on the settings, some data may not be displayed.

   For details, refer to the Instruction Manual.

   Operation will stop when the level is switched from Operation Level to Initial

   Setting Level.

                                      POWER ON                                                                         Press      for at least 1 second.

                                                     Press                                        Press  for at least 3 seconds.

                                                     +

                                                  for at least             Press        for less

                                                  3 seconds.               than 1 second.

                                                     Press                                        Adjustment                      Initial Setting

                                   Protect           +          Operation                                Level                    Level

                                   Level          for at least  Level

                                                  1 second.                                       l.adj

                                                                                                                Adjustment        i n-t

                                                                                                         -      Level                    Input Type

                                                                                                         M                        0

                                   oapt     Operation/          2.5                                      at                       M

                                            Adjustment                     PV/SP                                AT Execute/       d-u

                                      0     Protect             0                                        off    Cancel                   Temperature

                                   M                            M                                               *1 *2             c      Unit

                                                                                                         M                        M

                                   i.n.p.t  Initial             al-1       Alarm Value                   ins    Temperature       cn.tl

                                      1     Setting             0                                        0.0    Input Shift              PID • ON/OFF

                                            Protect                                                                               onof

                                   M                            M                                        M                        M

                                   okpt     Operation           r.-.s                                    p      Proportional      cp

                                      0     Control Key         run        RUN/STOP                      8.0    Band                     Control Period

                                            Protect                        *1                                   *2                20

                                                                                                         M                        M      *2

                                                                                                         i      Integral Time     oreV   Direct/Reverse

                                                                                                         233    *2                or-r   Operation

                                                                                                         M                        M

                                                                                                         d      Derivative        alt1

                                                                                                         40     Time                     Alarm Type

                                                                                                         M      *2                2

                                                                                                  o.f.-.r       Manual Reset

                                                                                                         50.0   Value

                                                                                                         M

                                                                                                  h.y.s         Hysteresis

                                                                                                         1.0    *3

   *1.  This  item  is  displayed  when the Operation Control Key Protect setting is set to 4.

   *2.  This  item  is  displayed  only when PID control is selected.

   *3.  This  item  is  displayed  only when ON/OFF control is selected.

   Troubleshooting

   When an error has occurred, the display No.1 shows the error code.

   Take necessary measure according to the error code, referring the following table.

              Display                     Meaning                                                                      Action

   s.err                           Input error*1                Check the wiring of inputs, disconnections, short circuits and input type.

   (S.ERR)

   e111                            RAM memory error             Turn the power OFF then back ON again.*2

   (E111)

   e111/sum                        Non-volatile memory          Press the U and D Keys for at least 3 seconds to initialize the settings and clear the non-

   (E111)/(SUM)*3                  memory error                 volatile memory error.*2

   • The control output and the alarm output will turn OFF when an error                          still within the control range, [[[[ will be displayed for values

   occurs. (For s.err, the alarm output will be processed for a high                              under −1999. Under these conditions, the control output and alarm

   temperature error.)                                                                            output will operate normally.

   • If the input value exceeds the display limit (−1999 to 9999) but it is

   *1. This error is displayed only when the process value and set point are displayed.

   *2. If the display does not change, the Controller needs to be repaired.

        If operation returns to normal, then noise may have caused the problem. Check for noise.

   *3. e111 will be displayed on display No. 1 and sum will be displayed on display No. 2.

8
                                                                                                                                          E5CB

Safety Precautions

Refer to Safety Precautions for All Temperature Controllers.

                              !CAUTION                                  Precautions for Safe Use

                                                                        Be sure to observe the following precautions to prevent malfunction

Do not touch the terminals while power is being                         or adverse affects on the performance or functionality of the product.

supplied.                                                               Not doing so may occasionally result in faulty operation.

Doing so may occasionally result in minor injury due to                 1.  This product is specifically designed for indoor use only.

electric shock.                                                             Do not use this product in the following places:

Do not allow pieces of metal, wire clippings, or fine                   • Places directly subject to heat radiated from heating equipment.

metallic shavings or filings from installation to enter the             • Places subject to splashing liquid or oil atmosphere.

product. Doing so may occasionally result in electric                   • Places subject to direct sunlight.

shock, fire, or malfunction.                                            • Places subject to dust or corrosive gas (in particular, sulfide gas

Do not use the product where subject to flammable or                        and ammonia gas).

explosive gas. Otherwise, minor injury from explosion                   • Places subject to intense temperature change.

may occasionally occur.                                                 • Places subject to icing and condensation.

                                                                        • Places subject to vibration and large shocks.

Do not use the Temperature Controller or the USB-                       2.  Use and store the product within the rated ambient temperature

Serial Conversion Cable if it is damaged. Doing so may                      and humidity.

occasionally result in minor electric shock or fire.                        Gang-mounting two or more Temperature Controllers, or

                                                                            mounting Temperature Controllers above each other may cause

Never disassemble, modify, or repair the product or                         heat to build up inside the Temperature Controllers, which will

touch any of the internal parts. Minor electric shock, fire,                shorten their service life. In such a case, use forced cooling by

or malfunction may occasionally occur.                                      fans or other means of air ventilation to cool down the

                                                                            Temperature Controllers.

CAUTION - Risk of Fire and Electric Shock                               3.  To allow heat to escape, do not block the area around the product.

a) More than one disconnect switch may be required to                       Do not block the ventilation holes on the product.

de-energize the equipment before servicing the                          4.  Be sure to wire properly with correct polarity of terminals.

product.                                                                5.  Use the specified size of crimp terminals for wiring (M3.5, width of

b) Caution: To reduce the risk of fire or electric shock, do                7.2 mm or less). For open-wired connections use stranded or solid

not interconnect the outputs of different Class 2                           copper wires with a gauge of AWG24 to AWG14 (equal to a cross-

circuits. *                                                                 sectional area of 0.205 to 2.081 mm2). (The stripping length is 5 to

If the output relays are used past their life expectancy,                   6 mm.) Up to two wires of the same size and type or two crimp

contact fusing or burning may occasionally occur.                           terminals can be connected to one terminal. Do not connect more

Always consider the application conditions and use the                      than two wires or more than two crimp terminals to the same

output relays within their rated load and electrical life                   terminal.

expectancy. The life expectancy of output relays varies                 6.  Do not wire the terminals that are not used.

considerably with the output load and switching                         7.  To avoid inductive noise, keep the wiring for the product’s terminal

conditions.                                                                 block away from power cables carry high voltages or large

                                                                            currents. Also, do not wire power lines together with or parallel to

Tighten the terminal screws to the rated torque of                          product wiring. Using shielded cables and using separate conduits

between 0.74 and 0.90 N·m. Loose screws may                                 or ducts is recommended.

occasionally result in fire.                                                Attach a surge suppressor or noise filter to peripheral devices that

                                                                            generate noise (in particular, motors, transformers, solenoids,

Set the parameters of the product so that they are                          magnetic coils, or other equipment that have an inductance

suitable for the system being controlled. If they are not                   component).

suitable, unexpected operation may occasionally result                      When a noise filter is used at the power supply, first check the

in property damage or accidents.                                            voltage or current, and attach the noise filter as close as possible

A malfunction in the product may occasionally make                          to the product.

control operations impossible or prevent alarm outputs,                     Allow as much space as possible between the product and

resulting in property damage. To maintain safety in the                     devices that generate powerful high frequencies (high-frequency

event of malfunction of the product, take appropriate                       welders, high-frequency sewing machines, etc.) or surge.

safety measures, such as installing a monitoring device                 8.  Use this product within the rated load and power supply.

on a separate line.                                                     9.  Make sure that the rated voltage is attained within two seconds of

Do not allow pieces of metal or wire cuttings to get inside                 turning ON the power using a switch or relay contact. If the voltage

the USB-Serial Conversion Cable connector for the                           is applied gradually, the power may not be reset or output

Support Software. Failure to do so may occasionally                         malfunctions may occur.

result in minor electric shock, fire, or damage to                      10.Make sure that the Temperature Controller has 30 minutes or

equipment.                                                                  more to warm up after turning ON the power before starting actual

                                                                            control operations to ensure the correct temperature display.

Do not allow dust and dirt to collect between the pins in               11.A switch or circuit breaker must be provided close to the product.

the connector on the USB-Serial Conversion Cable.                           The switch or circuit breaker must be within easy reach of the

Failure to do so may occasionally result in fire.                           operator, and must be marked as a disconnecting means for this

                                                                            unit.

* A class 2 power supply is one tested and certified by UL as having    12.Do not use paint thinner or similar chemical to clean with. Use

the current and voltage of the secondary output restricted to specific      standard grade alcohol.

levels.                                                                 13.Design the system (e.g., control panel) considering the 2 seconds

                                                                            of delay that the product's output to be set after power ON.

                                                                        14.The output may turn OFF when shifting to certain levels. Take this

                                                                            into consideration when performing control.

                                                                        15.The number of non-volatile memory write operations is limited.

                                                                            Therefore, use RAM write mode when frequently overwriting data

                                                                            during communications or other operations.

                                                                        16.Always touch a grounded piece of metal before touching the

                                                                            Temperature Controller to discharge static electricity from your

                                                                            body.

                                                                                                                                                  9
E5CB

17.Control outputs (for driving SSR) that are voltage outputs are not     3.  When two or more Temperature Controllers are mounted

    isolated from the internal circuits. When using a grounded                horizontally close to each other or vertically next to one another,

    thermocouple, do not connect any of the control output terminals          the internal temperature will increase due to heat radiated by the

    to ground. (Doing so may result in an unwanted circuit path,              Temperature Controllers and the service life will decrease. In such

    causing error in the measured temperature.)                               a case, use forced cooling by fans or other means of air ventilation

18.Use suitable tools when taking the Temperature Controller apart            to cool down the Temperature Controllers. When providing forced

    for disposal. Sharp parts inside the Temperature Controller may           cooling, however, be careful not to cool down the terminals

    cause injury.                                                             sections alone to avoid measurement errors.

19.Do not use the Temperature Controller if the front sheet is peeling    Measurement Accuracy

    off or torn.

20.Check the orientation of the connectors on the USB-Serial              1.  Mount the product so that it is horizontally level.

    Conversion Cable before connecting the Cable. Do not force a          2.  If the measurement accuracy is low, check to see if input shift has

    connector if it does not connect smoothly. Using excessive force          been set correctly.

    may damage the connector.

21.Do not place heavy object on the USB-Serial Conversion Cable,          Waterproofing

    bend the cable past its natural bending radius, or pull on the cable  The degree of protection is as shown below. Sections without any

    with undue force.                                                     specification on their degree of protection or those with IP@0 are not

22.Do not connect or disconnect the USB-Serial Conversion Cable           waterproof.

    while communications are in progress. Product faults or                   Front panel: IP66

    malfunction may occur.                                                    Rear case: IP20, Terminal section: IP00

23.Make sure that the Conversion Cable's metal components are not

    touching the external power terminals.                                Operating Precautions

24.Do not touch the connectors on the USB-Serial Conversion Cable

    with wet hands. Electrical shock may result.                          1.  It takes approximately two seconds for the outputs to turn ON from

25.The computer may operate incorrectly. Do not rapidly and                   after the power supply is turned ON. Due consideration must be

    repeatedly insert and disconnect the USB connector on the USB-            given to this time when incorporating Temperature Controllers in a

    Serial Conversion Cable.                                                  sequence circuit.

26.The personal computer requires time to recognize the cable             2.  When starting operation after the Temperature Controller has

    connection after the USB connector is connected to the personal           warmed up, turn OFF the power and then turn it ON again at the

    computer. This delay does not indicate failure. Check the COM             same time as turning ON power for the load. (Instead of turning the

    port number before starting communications.                               Temperature Controller OFF and ON again, switching from STOP

27.The USB-Serial Conversion Cable may malfunction. Do not                    mode to RUN mode can also be used.)

    connect to a personal computer through a USB hub.                     3.  Avoid using the Controller in places near a radio, television set, or

28.For the power supply voltage input, use a commercial power                 wireless installing. These devices can cause radio disturbances

    supply with an AC input. Do not use the output from an inverter as        which adversely affect the performance of the Controller.

    the power supply. Depending on the output characteristics of the      4.  When complying with EMC standards, the cable connecting the

    inverter, temperature increases in the product may cause smoke            sensor to the TC or Pt input must be 30 m or less. If the cable

    or fire damage even if the product has a specified output frequency       length exceeds 30 m, compliance with EMC standards will not be

    of 50/60 Hz.                                                              possible.

29.Make sure that the indicators on the Temperature Controller are        Mounting

    operating properly. Depending on the application conditions,

    deterioration in the connectors and cable may be accelerated, and     Mounting to a Panel

    normal communications may become impossible. Perform                  For waterproof mounting, waterproof packing must be installed on the

    periodic inspection and replacement.                                  Controller. Waterproofing is not possible when group mounting

30.When extending or connecting the thermocouple lead wire, be            several Controllers. Waterproof packing is not necessary when there

    sure to use compensating wires that match the thermocouple            is no need for the waterproofing function.

    types.

31.When extending or connecting the lead wire of the platinum             1.  Insert the E5CB into the mounting hole in the panel.

    resistance thermometer, be sure to use wires that have low            2.  Push the adapter from the terminals up to the panel, and

    resistance and keep the resistance of the three lead wires the            temporarily fasten the E5CB.

    same.                                                                 3.  Tighten the two fastening screws on the adapter. Alternately

32.The USB-Serial Conversion Cable may malfunction. Do not                    tighten the two screws little by little to maintain a balance. Tighten

    extend the USB cable with an extension cable to connect to the            the screws to a torque of 0.29 to 0.39 N·m.

    personal computer.                                                    Precautions when Wiring

33.Noise may enter on the USB-Serial Conversion Cable, possibly

    causing equipment malfunctions. Do not leave the USB-Serial           • Separate input leads and power lines in order to prevent external

    Conversion Cable connected constantly to the equipment.                   noise.

Precautions for Correct Use                                               • Use AWG24 (cross-sectional area: 0.205 mm2) to AWG14 (cross-

                                                                              sectional area: 2.081 mm2) shielded twisted-pair cable.

Service Life                                                              • Use crimp terminals when wiring the terminals.

1.  Use the product within the following temperature and humidity         • Use the suitable wiring material and crimp tools for crimp terminals.

    ranges:                                                               • Tighten the terminal screws to a torque of between 0.74 and 0.90

    Temperature: −10 to 55°C (with no icing or condensation)                  N·m.

    Humidity: 25% to 85%

    If the product is installed inside a control board, the ambient

    temperature must be kept to under 55°C, including the                                                   7.2 mm max.

    temperature around the product.

2.  The service life of electronic devices like Temperature Controllers

    is determined not only by the number of times the relay is switched

    but also by the service life of internal electronic components.                                         7.2 mm max.

    Component service life is affected by the ambient temperature: the

    higher the temperature, the shorter the service life and, the lower

    the temperature, the longer the service life. Therefore, the service

    life can be extended by lowering the temperature of the

    Temperature Controller.

10
MEMO

      11
    MEMO

12
MEMO

      13
    MEMO

14
Warranty and Application Considerations

                                 Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you

have any questions or comments.

                                 Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or

other period if specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,

MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER

ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET

THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR

IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS,

OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON

CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE

PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,

INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE

MODIFICATION OR REPAIR.

                                 Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of

products in the customer's application or use of the products.

Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will

be used.

Know and observe all prohibitions of use applicable to this product.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT

ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON

PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR

SYSTEM.

                                                        Disclaimers

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a

warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application

requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with

your OMRON representative at any time to confirm actual specifications of purchased product.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
OMRON Corporation                 Industrial Automation Company                               Authorized Distributor:

Tokyo, JAPAN

                  Contact:    www.ia.omron.com

Regional Headquarters

OMRON EUROPE B.V.                              OMRON ELECTRONICS LLC

Wegalaan 67-69-2132 JD Hoofddorp               One Commerce Drive Schaumburg,

The Netherlands                                IL 60173-5302 U.S.A.

Tel: (31)2356-81-300/Fax: (31)2356-81-388      Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

OMRON ASIA PACIFIC PTE. LTD.                   OMRON (CHINA) CO., LTD.                        © OMRON Corporation 2010  All Rights Reserved.

No. 438A Alexandra Road # 05-05/08 (Lobby 2),  Room 2211, Bank of China Tower,                In the interest of product improvement,

Alexandra Technopark,                          200 Yin Cheng Zhong Road,                      specifications are subject to change without notice.

Singapore 119967                               PuDong New Area, Shanghai, 200120, China       CSM_8_3_0317                             Printed in   Japan

Tel: (65) 6835-3011/Fax: (65) 6835-2711        Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200  Cat. No. H172-E1-01                                   1110
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

E5CB-R1P AC100-240      E5CB-R1TCD AC/DC24  E5CB-Q1TCD AC/DC24  E5CB-Q1P AC100-240  E5CB-R1TC

AC100-240  E5CB-R1PD AC/DC24  E5CB-Q1PD AC/DC24  E5CB-Q1TC AC100-240

小广播

E5CB-R1P-AC100-240器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved