datasheet

电子工程世界电子工程世界电子工程世界

型号

产品描述

搜索
 

E5C2-R20L-D-10-212F-AC24

器件型号:E5C2-R20L-D-10-212F-AC24
器件类别:热门应用    机电_工控_自动化   
文件大小:8150.43KB,共7页
厂商名称:OMRON
厂商官网:https://www.omron.com
下载文档

器件描述

Controllers R20L-D SAME AS R20J-DIN

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Omron
产品种类:
Product Category:
Controllers
RoHS:N
系列:
Series:
E5C2
商标:
Brand:
Omron Automation and Safety
工厂包装数量:
Factory Pack Quantity:
1
零件号别名:
Part # Aliases:
E5C2R20LD10212FAC24
单位重量:
Unit Weight:
3.527396 oz

E5C2-R20L-D-10-212F-AC24器件文档内容

    Temperature Controller

    E5C2

                                                                                                                                                        CSM_E5C2_DS_E_7_1

DIN-sized (48 x 48 mm) Temperature

Controller with Analog Setting

• Compact, low-cost Temperature Controller.

• Incorporates proportional control and reset adjustment function.

• Consecutive mounting possible using mounting adapter.

• Incorporates a plug-in socket, thus allows to DIN-track and flush

mounting.

         Refer to Safety Precautions for All Temperature

         Controllers.

                                                                                                          For the most recent information on models that have been certified for

                                                                                                          safety standards, refer to your OMRON website.

Model Number Structure

■ Model Number                        Legend

E5C2- @ @ @ @

    1          2  3    4   5

1.  Control Outputs                                        3.   Input                                                           Note: A functional explanation is provided

    R:   Relay                                                  K:       K-type thermocouple                                           here for illustration, but models are

2.  Control Method                                              J:       J-type thermocouple                                           not necessarily available for all

    20:  ON-OFF control                                         P-D:     Platinum resistance thermometer                               possible combinations. Refer to

                                                                         (Pt100)                                                       Ordering Information when ordering.

    40:  Proportional control                                                                                                          Examples

                                                                G:       Thermistor with replaceable ele-                           • Relay control output, ON/OFF

                                                                         ment                                                          control, type-K thermocouple input:

                                                                                                                                       E5C2-R20K

                                                                                                                                    • Relay control output, proportional

                                                                                                                                       control, thermocouple input: E5C2-

                                                                                                                                       R40P-D

Ordering Information

■ Temperature Controllers

                                             Input                          Thermocouple                              Resistance Thermometer                   Thermistor

                                                                    K (CA)                            J (IC)               Platinum resistance                 Thermistor

                                                           Chromel vs. alumel                 Iron    vs. constantan       thermometer Pt100                 (replaceable element)

                                             1,200                                     1,200                                                            Themistor nominal resistance

                               Standard      1,000                              1,000                                                                   6 k   6 k   30 k  550   4 k

                                      scale  800                          800                                                                           (0°C)  (0°C)  (0°C) (200°C)(200°C)

                                      (°C)   600                     600

                                             400                400                                           400                                  400

                                             300           300                                        300                                     300                                   300

                                             200      200                                     200                                        200                          150    200

                                             100                                                                      50   80   50  100                 50     100

                                             0                                                                                                                               100    150

                                             100     0    0    0     0     0   0      0           0  0       0                 0   0    0    0    0           0      50

                                                                                                                      50  20                          50

         Indica-                             Minimum

Setting  tion     Control             scale division  5    10   10   20     20  25     25          5  10      10      2    2    1   2    5    10   10   2      2      2      2        2

method   method   mode        Output         (°C)

Analog   No       ON/OFF      Relay   Model           E5C2-R20K                               E5C2-R20J               E5C2-R20P-D                       E5C2-R20G

setting  indi-    Propor-                             E5C2-R40K                 ---           ---                     ---                               ---

         cation   tional      Relay   Model

                  (P)

Note: When placing an order, specify the temperature range in addition to the model number.

                                                                                                                                                                                            1
                                                                                                                                          E5C2

Standard Models

                   Indication method        No indication                                  Indication method               No indication

                           Control mode   ON/OFF        Proportional                             Control mode                  ON/OFF

                                                              (P)               Input              Output                      Relay

        Input                   Output               Relay            Input/  Resis-   Platinum    50 to 50               E5C2-R20P-D

Input/  Thermo-  K (CA)      0  to 200    E5C2-R20K  E5C2-R40K        stan-   tance    resistance  20 to 80               E5C2-R20P-D

stan-   couple   Chromel     0  to 300    E5C2-R20K  E5C2-R40K        dard    Ther-    thermom-

dard             vs. alumel                                           scale   mome-    eter Pt100  0 to 50                 E5C2-R20P-D

scale                        0  to 400    E5C2-R20K  E5C2-R40K        (°C)    ter                  0 to 100                E5C2-R20P-D

(°C)                         0  to 600    E5C2-R20K  E5C2-R40K

                                                                                                   0 to 200                E5C2-R20P-D

                             0  to 800    E5C2-R20K  E5C2-R40K                                     0 to 300                E5C2-R20P-D

                             0  to 1,000  E5C2-R20K  ---                                           0 to 400                E5C2-R20P-D

                             0  to 1,200  E5C2-R20K  ---                      Ther-    THE (re-    50 to 50               E5C2-R20G

                 J (IC)      0  to 200    E5C2-R20J  ---                      mistor   placeable   0 to 100                E5C2-R20G

                 Iron vs.    0  to 300    E5C2-R20J  ---                               element)

                 constantan                                                                        50 to 150               E5C2-R20G

                             0  to 400    E5C2-R20J  ---                                           100 to 200              E5C2-R20G

                                                                                                   150 to 300              E5C2-R20G

■ Accessories (Order Separately)

Sockets                                                               Protective Cover

                         Name                                 Model                Type                        Model

Front Connecting Socket                              P2CF-08          Hard Protective Cover        Y92A-48B

Back Connecting Socket                               P3G-08

Front Connecting Socket with Finger Protection       P2CF-08-E

Protective Cover (for finger protection)             Y92A-48G

Specifications

■ Ratings                                                             ■ Characteristics

Supply voltage     100 to 240 VAC 50/60 Hz                            Setting accuracy      2% FS max.

Operating voltage  90% to 110% of rated supply voltage                Hysteresis            Approx. 0.5% FS (fixed)

range                                                                 Proportional band     3% FS (fixed)

Power              Approx. 3.6 VA                                     Control period        Approx. 20 s

consumption                                                           Reset range           5 1% FS min. (See note 1.)

Input              Thermocouple (with sensor burnout detection        Insulation            20 M min. (at 500 VDC)

                   circuit), platinum resistance thermometer, or      resistance

                   thermistor with replaceable element                Dielectric strength   2,000 VAC, 50/60 Hz for 1 min between charged termi-

Control method     ON/OFF or proportional control                                           nals and uncharged metallic parts

Setting method     Analog setting                                     Vibration             Malfunction: 10 to 55 Hz, 0.15-mm single amplitude for

                                                                      resistance                          10 min each in X, Y, and Z directions

Indication         No indication                                                            Destruction: 16.7 Hz, 2-mm double amplitude for 2 hrs

method                                                                                                    each in X, Y, and Z directions

Control output     Relay output: SPDT, 3 A at 250 VAC, resistive      Shock resistance      Malfunction: 147 m/s2, 3 times each in 6 directions

                                   load (switching capacity: 330 VA)                        Destruction: 294 m/s2, 3 times each in 6 directions

Ambient operat-    10C to 55C (with no icing or condensation)      Life expectancy       Electrical:     100,000 operations min. (3 A at 110 VAC,

                                                                                                          resistive load)

ing temperature                                                       Weight                Approx. 100 g (with flush-mounting adapter)

Ambient operat-    45% to 85%                                         Degree of protection  Front panel: IEC standard IP40 (See note 2.)

ing humidity                                                                                Terminals:      IEC standard IP00

                                                                      Applicable Socket     P2CF-08 (order separately),

Note: Do not use an inverter output as the power supply. (Refer to                          P3G-08 (order separately)

        Safety Precautions for All Temperature Controllers.)          Applicable Protec-    Y92A-48B (order separately)

                                                                      tive Cover

                                                                      Note: 1.    No reset function is incorporated by any E5C2 model with

                                                                                  ON/OFF control.

                                                                                  The reset function is used to correct offset for proportional

                                                                                  control. If there is an offset below the set value, turn the

                                                                                  reset adjustment clockwise.

                                                                              2.  A special Watertight Cover is used to achieve this degree of

                                                                                  protection (IP66, NEMA4). Refer to Y92A-@@N.

                                                                                                                                                      2
                                                                                                                                     E5C2

■ Connections

Connecting the Input                                                      Output

• Connect a thermocouple, the E52-THE@ Thermistor (replaceable            • If the load circuit is a heating control system, be sure to connect the

   element) or a platinum resistance thermometer to terminals 1           load to terminals 4 and 5. If the load circuit is a cooling control

   (positive) and 2 (negative) on the E5C2 as shown in the following      system, be sure to connect the load to terminals 4 and 6.

   illustration.                                                          • We recommend using an external relay to extend the electrical life

                                                                          of internal relays when driving a large capacity load. This is

                                                                          particularly important when the output relay is switched frequently

                  Platinum resistance                                     (e.g., with proportional control).

                  thermometer input

                                                                          Power Supply

   Thermocouple input                                                     • If a single power supply is used for the E5C2 and the load, the

                                                                          supply voltage of the power supply may vary greatly when the load

                                                                          is open or closed if the capacity of the power supply is not large

                                                                          enough. Make sure that the capacity of the power supply is large

                                       Power supply                       enough so that the supply voltage range will be always from 90% to

                                       100/110/120 VAC (same model) or    110% of the rated supply voltage.

   Thermistor with                     200/220/240 VAC (same model)

   replaceable element                 50/60 Hz                           • The E5C2 operates at either 50 or 60 Hz.

•  On the E52-@@1D, the lead wires are thermocouple element wires,

   making them difficult to solder because solder will not stick to them

   easily. Remove the crimp terminal and polish the ends before

   attempting to solder them.

Nomenclature

   Temperature setting knob                                               Operation Indicator

                                                                               Indicator                      Output

                                       Operation indicator                                NO contacts (4 and 5) NC contacts (4 to 6)

                                                                          Red  Lit        ON                          OFF

                                                                               Not lit    OFF                         ON

                               RESET adjustment shaft

                               No reset function is incorporated by any

                               E5C2 model with ON/OFF control.

                                                                                                                                                     3
                                                                                                                                                    E5C2

Dimensions

Note: All units are in millimeters unless otherwise indicated.

                                                                                                                   Terminal Arrangement

                            48 x 48                                                                                (Bottom View)

                                                                                          44.8 x 44.8

Dimensions with Flush-mounting Adapter (Accessory),

and Back Connecting Socket (Sold Separately)                                              Panel

                                                                          Flush-mounting        Y92F-30  Flush-mounting adapter

                                                                          adapter                                               P3G-08 Back

                                                                                                                                connecting socket

                                                                                                         Tightening screw

                                                                                                         (96)

              Panel Cutout                                      Side-by-side Mounting

                                                                of N Controllers

                                                                                          Qty.   2       3      4       5       6

                                                                                          L      93+01  141+01  189+01  237+01  285+01

              60 min.

                                                                Note: 1. Recommended panel thickness is 1 to 4 mm.

                                                                          2. Close side-by-side mounting is possible (in a              single  direction).

■ Accessories (Order Separately)

Connection Sockets

P2CF-08 Front Connecting Socket

                                                                                             Terminal Arrangement/                      Mounting Holes

                                                                                             Internal Connections

                            Eight, M3.5 x 7.5 sems                                           (Top View)

                                                                                                                                        Two, 4.5 dia. or two, M4

                            70 max.

                                                                Two,

                                                                4.5-dia.                                                        Note: Can also be

                                                                holes                                                                   mounted to a

                                                                                                                                        DIN track.

                                       50 max.

                                                                          20 max.

                                                                          Note: A  finger-protection  model     (P2CF-08-E) is also available.

P3G-08  Back  Connecting  Socket (for  Flush Mounting)                                                                  Terminal Arrangement/

                          27 dia.                                                                                       Internal Connections

                                                                                                                        (Bottom View)

                                                                          Note: A Protective Cover for finger protection (Y92A-48G) is also available.

                                                                                                                                                                  4
                                                                                                                                   E5C2

Hard Protective Cover                                                   Applicable Thermistor

A Hard Protective Cover (Y92A-48B) is available. It can be used in      Connect a Thermistor with a replaceable element (E52-THE5A, E52-

the following cases.                                                    THE6D, or E52-THE6F) to the E5C2-R20G. Refer to E52 for details.

• To protect the setting section, against dust and dirt

• To prevent accidently changing settings by touching the front of the

Controller.

• To protect the Controller from water drips

Appearance

Model                                              Y92A-48B

Safety Precautions

Refer to Safety Precautions for All Temperature Controllers.

■ Correct Use

Mounting                                                                The P3G-08 can be wired in the same way as the P2CF-08.

Track Mounting (E5C2 with P2CF-08)

When mounting two or more E5C2 models with track-mounting

sockets, leave a space of approximately 20 mm on both sides of the

sockets where hooks are located.

                                               Hook                     Dismounting

                                                     Duct               If flush mounted, loosen the screw of the adapter and disengage the

                                                                        hooks for dismounting.

                             P2CF-08

                      Panel                    20

Flush Mounting

Insert E5C2 into the square hole of the panel and insert an adapter

from the back so that there will be no space between E5C2 and the

panel. Then, secure the E5C2 with a screw.                              Temperature Setting

                                                                        Do not turn the temperature setting knob of the E5C2 with excessive

                                                                        force, otherwise the stopper of the knob may break.

                                                                        Others

                                                                        •  Do not remove the housing of the E5C2, otherwise the housing

                             Tightening screw                              may break.

                                                                        •  To clean the surface of the E5C2, use a soft cloth wet with neutral

                                                                           detergent or alcohol. Do not use any organic solvent, such as paint

                                                                           thinner or benzine, strong acid or strong alkali to clean the surface

                                                                           of the E5C2, otherwise the surface of the E5C2 will become

                                                                           damaged.

                      ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                      To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                  In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                                  5
                                                     Terms and Conditions Agreement

Read and understand this catalog.

Please read and understand this catalog before purchasing the products.                 Please consult your OMRON representative if you

have any questions or comments.

Warranties.

(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship

for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron

disclaims all other warranties, express or implied.

(b)  Limitations.      OMRON    MAKES           NO   WARRANTY          OR   REPRESENTATION,         EXPRESS             OR   IMPLIED,      ABOUT

NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER

ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE

PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.

Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the

Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at

Omron’s     election,  to  (i)  replace    (in  the  form  originally  shipped    with  Buyer  responsible  for  labor  charges  for  removal            or

replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount

equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,

repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products

were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate

modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall

not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or

electronic   components,        circuits,  system    assemblies  or    any  other  materials   or   substances   or  environments.    Any  advice,

recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above

warranty.

See http://www.omron.com/global/           or contact your Omron representative for published information.

Limitation on Liability; Etc.

OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,

LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,

WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.

Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.

Omron     Companies    shall    not  be    responsible     for  conformity  with  any   standards,  codes   or  regulations  which  apply  to            the

combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable

third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself

is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,

system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product

with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE

QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE

OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.

Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence

thereof.

Performance Data.

Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining

suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate

it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.

Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our

practice to change part numbers when published ratings or features are changed, or when significant construction changes are

made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers

may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at

any time to confirm actual specifications of purchased Product.

Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.

                                                                                                                                           2013.10

                                                           In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

http://www.ia.omron.com/                                                                       (c)Copyright OMRON Corporation 2013 All Right Reserved.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

E5C2-R40J-0-200C-32-392F-AC120        E5C2-R20J-0-200C-32-392F-AC120    E5C2-R20K-32-1832F-AC120   E5C2-

R20G-122/392F-AC120     E5C2-R20G-58/122F-AC120   E5C2-R20G AC100-120 32-212FW  E5C2-R20J-32/392F-AC24

E5C2-R20J-399C-AC120    E5C2-R20J-399C-AC240      E5C2-R20J AC100-120 0-300    E5C2-R20K-0-600C AC240  E5C2-

R20K-1112F-AC120   E5C2-R20K 1472FAC-120     E5C2-R20K-2192F-AC120      E5C2-R20K-32/572F-AC240    E5C2-R20K-

32/752F-AC120    E5C2-R20K-32/752F-AC240     E5C2-R20K AC100-120 0-200  E5C2-R20K AC100-120 0-600  E5C2-

R20K AC200-240 0-200    E5C2-R20L-D-10-212F-AC24  E5C2-R20LDAC1001200400       E5C2-R20L-DIN 0/200C AC240

E5C2-R20LDIN-0/400C-AC240      E5C2-R20P-D-32/392F-AC120  E5C2-R20P-D AC100-120 0-300C   E5C2-R20P-D

AC110/120 0-400    E5C2-R20P-D AC220/240 32-572F  E5C2-R20PDIN-200C-AC120      E5C2-R20PDIN-212F-AC120

E5C2-R20PDIN32/122F-AC240      E5C2-R20PDIN32/572F-AC120  E5C2-R20PDIN-50C-AC240    E5C2-R40J-10-200F-

AC240    E5C2-R40J-392F-AC240  E5C2-R40J-399C-AC240  E5C2-R40J-572F-AC120      E5C2-R40J-572F-AC240

E5C2-R40J-750F-AC240    E5C2-R40K-1112F-AC120     E5C2-R40K-1472F-AC120      E5C2-R40K-32/1112F-AC220/240

E5C2-R40K-32/2192F-AC120   E5C2-R40K 32-392F AC100-120    E5C2-R40K-32/752F-AC120   E5C2-R40P-DIN-

32/392F-AC240    E5C2-R20K AC100-120 0-1200    E5C2-R20J-0400C/32752F-AC120    E5C2-R20K AC200-240 0-400

E5C2-R20K-32/392F-AC120    E5C2-R20J-32/572F-AC120   E5C2-R20K-32/1112F-AC240   E5C2-R20J-0400C/32752F-

AC240    E5C2-R20J-W/32-752 AC100/120   E5C2-R20J-0400C/32-752F-AC240    E5C2-R40J-0-400C-32-752F-AC120

E5C2-R20K-W-1112F-AC120    E5C2-R20J-W AC100-240 32-392   E5C2-R20K-W AC100-240 32-1112  E5C2-R20P-D-W

AC100-240 32-392   E5C2-R20J-W AC100-240 32-752   E5C2-R20J-W AC100-240 32-572  E5C2-R20K-W AC100-240

32-2192  E5C2-R20K-W AC100-240 32-1832    E5C2-R20P-DIN-50/50C-AC120     E5C2-R20P-DIN-50C-AC240   E5C2-

R20J-0-200C-32-39  E5C2-R20J-0400C/32-752F-AC120    E5C2-R20J-0-200C-32-392F-AC240  E5C2-R20K 14/72F-

AC120    E5C2-R20L-D-AC100-120 0-400   E5C2-R20L-DIN-0/400C-AC240     E5C2-R20P-DIN-200C-AC120    E5C2-R20P-

DIN-212F-AC120    E5C2-R20P-DIN-32/122F-AC240     E5C2-R20P-DIN-32/572F-AC120

小广播

E5C2-R20L-D-10-212F-AC24器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved