E5AZ-R3MTD AC/DC24

器件型号:E5AZ-R3MTD AC/DC24
器件类别:热门应用    测试测量   
厂商名称:OMRON
厂商官网:https://www.omron.com
标准:  
下载文档

器件描述

mexla TC rly out 3 alm

参数
Datasheets:
E5xZ:
PCN Design/Specification:
Multiple devices Modification July/2013:
Standard Package : 1
Category: Industrial Controls, Meters
Family: Controllers - Process, Temperature
Series: E5AZ
Type: Temperature Controller (RTD, Type B, E, J, K, L, N, R, S, T, U)
Input Range: -200°C ~ 1800°C, 0 ~ 50mV
Output Type: Relay (4)
Control Method: On/Off, Proportional (PID)
Communications: Option Cards Available
Number Of Characters Per Row: 4, 4
Display Type: LCD - Dual Color Characters, Backlight
Display Characters - Height: 0.590" (15.00mm), 0.374" (9.50mm)
Voltage - Supply: 24VAC/DC
Panel Cutout Dimensions: Square - 92.00mm x 92.00mm
Mounting Type: Panel Mount
Termination Style: Screw Terminal
Ingress Protection: IP66 (Face), IP20 (Case), IP00 (Terminal)
Operating Temperature: -10°C ~ 55°C
Features: Option Cards Available
Weight: 0.662 lb (300.28g)
Associated Product: Y92S-P5-ND - WATER PROOF PACKINGE53-AZB-ND - ACCY EVENT INPUT UNITE53-AZ03-ND - ACCY COMMUNICATION UNIT RS485E53-AZ01-ND - ACCY COMMUNICATION UNIT RS232E58-CIFQ1-ND - CABLE USB-SERIAL CONVERSIONE54-CT3-ND - TRANSFORMER CURRENT 12MM DIAE53-COV11-ND - COVER TERM FOR E5EN DIGTL CNTRLRZ2416-ND - TRANSFORMER CURRNT 50A E5AK/E5CK
Other Names: E5AZR3MTDACDC24

E5AZ-R3MTD AC/DC24器件文档内容

Digital Temperature Controllers

E5@Z

1/16, 1/8, and 1/4 DIN Temperature
Controllers Join the Best-selling
E5@Z Series

Models available with either temperature inputs or
  analog inputs.

A wide range of functions, such as a loop break alarm
  (LBA), manual output, and transfer output.

Easy-to-read 11-segment display.
Faster sampling at 250 ms.
Setting Tool port provided as a standard feature for easy

  connection to personal computers.
New protocol called Modbus is installed in the models

  with communications.

          E5@Z Series

E5CZ      E5EZ     E5AZ                                                                         Digital Position-proportional
                                                                                                Controller

                                                                                   E5EZ-PRR

1/16 DIN  1/8 DIN  1/4 DIN                                                         1/8 DIN

                   Contents

          Digital Temperature Controllers

          E5CZ/E5CZ-U..............................................    2

          E5AZ/E5EZ..................................................  14

          E5EZ-PRR...................................................  37

          Common to Updated E5@Z Controllers

             Operation...................................................... 26
             Precautions .................................................. 33
          E5EZ-PRR

          Operation...................................................... 43
          Precautions .................................................. 59

                                                                                                                               1
Digital Temperature Controllers

E5CZ/E5CZ-U(48 48 mm)

This Best-selling General-purpose                                                       48 48 mm    48 48 mm
4848-mm Temperature Controller                                                             E5CZ        E5CZ-U
Is Now Even Better.
                                                          Note: Refer to page 30 for information on changes in comparison to
Controllers now available with analog inputs.                   previous models.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and

  heater short alarm (HS alarm).
Easy setting with 11-segment displays.
Setting protection indicator informs operator when

  protection is enabled.
Manual output provided.
New protocol called Modbus is installed in the models

  with communications.
USB-Serial conversion cable is available.

Note: Refer to Precautions on page 33.

Main I/O Functions                                  E5CZ

                                      Event Inputs        2-level Display: PV and SV 4-digit Display
                                       None
                                       Two               Alarm Outputs                              Auto/manual switching
                                                          Two                                     Models also available with RS-485
   Sensor Inputs
    Universal thermocouple/Pt inputs                                                                communications

    (Models with temperature inputs)                Control Output 1
    Analog current/voltage inputs                   Relay output
                                                    Voltage output (for driving SSR)
    (Models with analog inputs)                      Current output

   Indication Accuracy
   E5CZ
    Thermocouple input: 0.5% of PV
    Pt input: 0.5% of PV
    Analog input: 0.5% FS
   E5CZ-U
    Thermocouple input: 1% of PV
    Pt input: 0.5% of PV

   Sampling Period
    250 ms

        This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
        and other information required for operation before attempting to use the product.
        E5CZ/E5CZ-U/E5AZ/E5EZ Digital Temperature Controllers User's Manual (Cat. No. H207)
        E5CZ/E5CZ-U/E5AZ/E5EZ Digital Temperature Controllers Communications Manual (Cat. No. H208)

2
Model Number Structure                                                                                 E5CZ/E5CZ-U

Model Number Legend                                                    Option Units

Controllers                                                            E53-CZ@@

E5CZ-@2M@@                                                                         1 23
                                                                       1. Applicable Controller
              123 4 5
                                                                          CZ: E5CZ
1. Control Output 1                                                    2. Function 1
   R: Relay output
   Q: Voltage output (for driving SSR)                                    Blank: None
   C: Current output                                                      H: Heater burnout/Heater short detection (CT1)
                                                                       3. Function 2
2. Number of Alarms                                                       B: Two event inputs
   2: Two alarms                                                          03: RS-485 communications

3. Option
   Blank: None
   M: Option Unit can be mounted.

4. Input Type
   T: Thermocouple, infrared sensor/platinum resistance
       thermometer
   L: Analog current/voltage input

5. Power Supply Voltage
   Blank: 100 to 240 VAC
   D: 24 VAC/VDC

Note: Not all combinations of function 1 and function 2 specifications are possible for Option Units (E53-CZ@@).

Ordering Information

Controllers with Terminal Blocks

Size  Power supply            Input type                 Alarm output   Mounting         Control output      Previous    New model
          voltage                                                      option units                            model   E5CZ-R2T
                                                                                       Relay output                    E5CZ-Q2T
                                                                       No              Voltage output     E5CZ-R2      E5CZ-R2MT
                                                                                       (for driving SSR)  E5CZ-Q2      E5CZ-Q2MT
                              Thermocouple or            2                             Relay output       E5CZ-R2M     E5CZ-C2MT
                              Resistance                                      Yes      Voltage output     E5CZ-Q2M     E5CZ-R2ML
                              thermometer                                              (for driving SSR)  E5CZ-C2M     E5CZ-Q2ML
                                                                                       Current output     None         E5CZ-C2ML
      100 to 240 VAC                                                                   Relay output       None         E5CZ-R2MTD
                                                                                       Voltage output     None         E5CZ-Q2MTD
1/16 DIN                      Analog                     2             Yes             (for driving SSR)  E5CZ-R2MD    E5CZ-C2MTD
48 48 78                  (current/voltage)                                        Current output     E5CZ-Q2MD    E5CZ-R2MLD
(W H D)                                              2             Yes             Relay output       E5CZ-C2MD    E5CZ-Q2MLD
                              Thermocouple or                                          Voltage output     None         E5CZ-C2MLD
                  24 VAC/VDC  Resistance                                               (for driving SSR)  None
                              thermometer                                              Current output     None
                                                         2             Yes             Relay output
                              Analog                                                   Voltage output
                              (current/voltage)                                        (for driving SSR)
                                                                                       Current output

Option Units

One of the following Option Units can be mounted to provide the E5CZ with additional functions.

                              Functions                                                Previous model                         New model
                                                                                                                  E53-CZ03
Communications RS-485                                                              E53-CN03N                      E53-CZH03
                                                                                                                  E53-CZB
Communications RS-485         Heater burnout                                       E53-CNH03N                     E53-CZHB

                                                         Event inputs              E53-CNBN

                              Heater burnout             Event inputs              E53-CNHBN

Note: Option Units cannot be used for plug-in models.
        These Option Units are applicable only to models released after October 2008.

                                                                                                                                         3
   E5CZ/E5CZ-U

   Model Number Structure

   Model Number Legend (Plug-in-type Controllers)

   E5CZ-@2T@U                                                             4. Power Supply Voltage
                 1 2 34 5                                                    Blank: 100 to 240 VAC
                                                                             D: 24 VAC/VDC
   1. Output Type
      R: Relay                                                            5. Plug-in type
      Q: Voltage output (for driving SSR)                                    U: Plug-in type

   2. Number of Alarms
      2: Two alarms

   3. Input Type
      T: Thermocouple, infrared sensor/platinum resistance
          thermometer

   Ordering Information (Plug-in-type Controllers)

   Plug-in-Type Controllers

       Size       Power supply        Input type            Alarm output  Control output            Previous                New model
   1/16 DIN            voltage                                                                       model                E5CZ-R2TU
                                Thermocouple or                                                                           E5CZ-Q2TU
             100 to 240 VAC     Resistance                                Relay output              None                  E5CZ-R2TDU
                                thermometer                                                                               E5CZ-Q2TDU
             24 VAC/VDC                                     2
                                Thermocouple or                                  Voltage output (for driving SSR) None
                                Resistance
                                thermometer                               Relay output              None

                                                            2
                                                                                 Voltage output (for driving SSR) None

   Accessories (Order Separately)                                         Adapter

   USB-Serial Conversion Cable

                          Model                                           Connectable models                            Model
                       E58-CIFQ1
                                                                          Terminal block models                         Y92F-45

   Terminal Cover                                                         Note: Use this Adapter when the panel has been previously prepared
                                                                                  for the E5B@.

   Connectable models           Terminal block models                     Sockets (for Plug-in Models)
   Model                        E53-COV17
                                                                                                      Type                   Model
   Waterproof Packing                                                     Front-connecting Socket                         P2CF-11
                                                                          Front-connecting Socket with Finger Protection  P2CF-11-E
                                            Model                         Back-connecting Socket                          P3GA-11
                                                                          Terminal Cover for Back-connecting socket with
                                           Y92S-29                        Finger Protection                               Y92A-48G
   Note: The Waterproof Packing is included with the Controller only for

           models with terminal blocks.

   Current Transformers (CTs)

   Hole diameter                   Model
        5.8 dia.                  E54-CT1
       12.0 dia.                  E54-CT3

4
                                                                                                   E5CZ/E5CZ-U

Specifications

Ratings

Power supply voltage                  100 to 240 VAC, 50/60 Hz                     24 VAC, 50/60 Hz or 24 VDC

Operating voltage range       85% to 110% of rated supply voltage

Power con- E5CZ               7.5 VA                                               5.5 VA (24 VAC)/3.5 W (24 VDC)

sumption      E5CZ-U          6 VA                                                 4.5 VA (24 VAC)/2.5 W (24 VDC)

Sensor input                  Models with temperature inputs
                                  Thermocouple: K, J, T, E, L, U, N, R, S, or B
                                  Platinum resistance thermometer: Pt100 or JPt100
                                  Infrared temperature sensor: 10 to 70C, 60 to 120C, 115 to 165C, or 140 to 260C
                                  Voltage input: 0 to 50 mV

                              Models with analog inputs
                                  Current input: 4 to 20 mA or 0 to 20 mA
                                  Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

Input impedance               Current input: 150 , Voltage input: 1 M (Use a 1:1 connection when connecting the ES2-HB.)

                              E5CZ    SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable
                                      load: 5 V, 10 mA
              Relay output
                                      SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load:
Control                       E5CZ-U  5 V, 10 mA
output
              Voltage output  E5CZ
              (for driving    E5CZ-U  Output voltage: 12 VDC 15% (PNP), max. load current: 21 mA, with short-circuit protection circuit
              SSR)
                              E5CZ 4 to 20 mA DC/0 to 20 mA DC, load: 600  max., resolution: approx. 2,700
              Current output
                              SPST-NO, 250 VAC, 1 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V,
Alarm output                  10 mA

              Contact input   ON: 1 k max., OFF: 100 k min.

Event input   Non-contact     ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
              input

Control method                Outflow current: Approx. 7 mA per point
Setting method
                              ON/OFF control or 2-PID control (with auto-tuning)
Indication method
                              Digital setting using front panel keys
Other functions
                              11-segment digital display and individual indicators (7-segments displays also possible)
Ambient operating             Character height: PV: 11 mm, SV: 6.5 mm
temperature
Ambient operating humidity    Manual output, heating/cooling control, transfer output (on some models), loop break alarm, multi SP, MV
Storage temperature           limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, etc.

                              -10 to 55C (with no icing or condensation)

                              25% to 85%
                              -25 to 65C (with no icing or condensation)

                                                                                                                                          5
   E5CZ/E5CZ-U

   Input Ranges

   Thermocouples/Platinum Resistance Thermometers (Universal Inputs)

                           Input              Platinum resistance                                                            Thermocouple                                                 Infrared temperature       Analog
                           Type                    thermometer                                                                                                                                     sensor             input

                           Name               Pt100         JPt100               K                          J             T            EL            U         N        R     S  B     10 to  60 to  115 to  140 to  0 to 50 mV
                                                                                                                                                                                       70C   120C  165C   260C

                           1800                                                                                                                                                  1800                                Usable in
                           1700                                                                                                                                                                                      the
                           1600                                                                                                                                      1700  1700                                      following
                           1500                                                                                                                                                                                      ranges by
                           1400                                            1300                                                                                1300                                                  scaling:
                           1300                                                                        850                                                                                                           -1999 to
   Temperature range (C)  1200                                                                                                                                                                                      9999 or
                           1100                                                                                                                                                                                      -199.9 to
                           1000                                                                                                                                                                                      999.9

                                         850                                                                                              850

                            900

                           800

                           700                                                                                                      600

                           600                500.0         500.0                   500.0

                           500                                                                                 400.0 400     400.0              400     400.0

                           400                                                                                                                                                                               260

                           300                                                                                                                                                                120    165

                           200                       100.0          100.0                                                                                                              90

                           100                                                                                                                                                   100

                                  0                  0.0            0.0                                                             0                                0     0           0      0      0       0

                           -100.0                                                   -20.0 -100 -20.0                                      -100

                           -200.0    -200 -199.9            -199.9         -200                                -200 -199.9                      -200 -199.9 -200

   Setting                           0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
   number

   The applicable standards for the input types                                               U: Cu-CuNi, DIN 43710-1985                                                   Shaded settings are the default settings.
   are as follows:                                                                            Pt100: IEC 751
                                                                                              JPt100: JIS C 1604-1989, JIS C 1606-1989
   K, J, T, E, N, R, S, B: IEC584-1

   L: Fe-CuNi, DIN 43710-1985

   Models with Analog Inputs

        Input Type                                          Current                                               Voltage
   Input specification
                                                     4 to 20mA 0 to 20 mA 1 to 5 V 0 to 5 V 0 to 10 V
   Setting range
                                                     Usable in the following ranges by scaling:
   Setting number                                    -1999 to 9999, -199.9 to 999.9, -19.99 to 99.99 or
                                                     -1.999 to 9.999

                                                     0              1                      2                   3                       4             Shaded settings are the default settings.

6
                                                                                                                       E5CZ/E5CZ-U

Alarm Types                                                            Note: 1. With set values 1, 4 and 5, the upper and lower limit values
                                                                                   can be set independently for each alarm type, and are
Select alarm types out of the 12 alarm types listed in the following               expressed as "L" and "H."
table.
                                                                               2. Set value: 1, Upper- and lower-limit alarm

                                  Alarm output operation               Case 1           Case 2                         Case 3 (Always ON)

   Set        Alarm type    When X is posi- When X is nega-              L H SP         SP L H                           H SP L                            H<0, L<0
  value                                                                                                                H L SP
          Alarm function          tive                      tive       H<0, L>0           H>0, L<0                                                         H<0, L>0
0         OFF                                                           |H| < |L|          |H| > |L|                                                        |H|  |L|
                            Output OFF                                                                                                                     H>0, L<0
1                                                                                                                                                           |H|  |L|
(See                                                                                                                                               SP H L
note 1.)  Upper- and lower- ON       LH                (See note 2.)
                                                                       3. Set value: 4, Upper- and lower-limit range
2         limit
                            OFF      SP
3
          Upper limit       ON            X            ON   X          Case 1           Case 2                         Case 3 (Always ON)                  H<0, L<0
4         Lower limit       OFF       SP               OFF   SP
(See                                 X                           X            L H SP      SP L H                              H SP L                       H<0, L>0
note 1.)                    ON        SP               ON    SP            H<0, L>0         H>0, L<0                       H L SP                           |H|  |L|
                            OFF                        OFF                   |H| < |L|        |H| > |L|

                                                                                                                       SP H L                              H>0, L<0
                                                                                                                                                            |H|  |L|

          Upper- and lower- ON       LH                (See note 3.)   4. Set value: 5, Upper- and lower-limit with standby sequence
                                                                           For Upper- and Lower-Limit Alarm Described Above
          limit range       OFF                                              Case 1 and 2
                                                SP

5         Upper- and lower- ON       LH                                Always OFF when the upper-limit and lower-limit
(See
note 1.)  limit with standby OFF     SP                (See note 4.)   hysteresis overlaps.
6
          sequence          (See note 5.)                               Case 3: Always OFF
7
          Upper-limit with  ON                      X  ON   X                  5. Set value: 5, Upper- and lower-limit with standby sequence
8                                                      OFF   SP                    Always OFF when the upper-limit and lower-limit hysteresis
          standby sequence OFF       SP                          X
9                                                      ON    SP                    overlaps.
          Lower-limit with  ON       X                 OFF    X
10                                                                  0          6. Set value: 12, LBA (loop break alarm) can be set only for
          standby sequence OFF       SP                ON     X                    alarm 1 type.
11                                                     OFF          0
          Absolute-value    ON         X                      X        Set the alarm types for alarms 1 to3 independently in the initialsetting
12        upper-limit       OFF   0                    ON           0
(See                                                   OFF             level. The default setting is 2 (upper limit).
note 6.)                                                      X
          Absolute-value    ON         X               ON           0
          lower-limit       OFF   0                    OFF

          Absolute-value    ON          X              ON
                            OFF                        OFF
          upper-limit with        0

          standby sequence

          Absolute-value    ON          X
                            OFF
          lower-limit with        0

          standby sequence

          LBA (for alarm 1  ---
          type only)

                                                                                                                                                                      7
   E5CZ/E5CZ-U

   Characteristics                                                                          Note: 1. The indication accuracy of K thermocouples in the -200 to
                                                                                                        1300C range, T and N thermocouples at a temperature of
   Indication accuracy       Thermocouple: (See note 1.)                                                -100C max., and U and L thermocouples at any
                             E5CZ: (0.5% of indicated value or 1C, whichever                         temperature is 2C 1 digit maximum. The indication
                                                                                                        accuracy of the B thermocouple at a temperature of 400C
                                          is greater) 1 digit max.
                             E5CZ-U: (1% of indicated value or 2C, whichever is                      max. is not specified. The indication accuracy of the R and
                                                                                                        S thermocouples at a temperature of 200C max. is 3C 1
                                          greater) 1 digit max.
                             Platinum resistance thermometer:                                           digit max.

                                          (0.5% of indicated value or 1C, whichever              2. "EU" stands for Engineering Unit and is used as the unit
                                          is greater) 1 digit max.                                     after scaling. For a temperature sensor, the EU is C or F.
                             Analog input: 0.5% FS 1 digit max.
                             CT input: 5% FS 1 digit max.                                         3. B, R, and S sensors: 0.2C/ max. (100  max.)
                                                                                                    4. There is no waterproof function for the E5CZ-U.
   Influence of temperature  R, S, and B thermocouple inputs:
   (See note 2.)             (1% of PV or 10C, whichever is greater) 1 digit max.       USB-Serial Conversion Cable
   Influence of voltage      Other thermocouple inputs:
   (See note 2.)             (1% of PV or 4C, whichever is greater) 1 digit max.
                             *10C for -100C or less for K sensors
                             Platinum resistance thermometer inputs:                        Applicable OS                     Windows 2000/XP/Vista
                             (1% of PV or 2C, whichever is greater) 1 digit max.
                             Analog inputs:                                                 Applicable software               Thermo Mini
                             (1% of FS) 1 digit max.

   Hysteresis                Models with thermocouple/platinum resistance                   Applicable models                 E5CZ/E5CZ-U/E5AZ/E5EZ
                             thermometer input (universal input):
                                                                                            USB interface standard            Conforms to USB Specification 1.1.
                                0.1 to 999.9 EU (in units of 0.1 EU)
                             Models with analog input:                                      DTE speed                         38400 bps

                                0.01 to 99.99% FS (in units of 0.01% FS)

   Proportional band (P)     Models with thermocouple/platinum resistance                   Connector specifications          Computer: USB (type A plug)
                             thermometer input (universal input):                                                             Temperature Controller: Setup Tool port
                                                                                                                              (on bottom of Controller)
                                0.1 to 999.9 EU (in units of 0.1 EU)
                             Models with analog input:                                                                        Bus power (Supplied from USB host
                                                                                                                              controller.)
                                0.1 to 999.9% FS (in units of 0.1% FS)

   Integral time (I)         0 to 3999 s (in units of 1 s)                                  Power supply

   Derivative time (D)       0 to 3999 s (in units of 1 s)                                  Power supply voltage              5 VDC

   Control period            0.5, 1 to 99 s (in units of 1 s)                               Current consumption               70 mA

   Manual reset value        0.0 to 100.0% (in units of 0.1%)                               Ambient operating temperature 0 to 55C (with no condensation or icing)

   Alarm setting range       -1999 to 9999 (decimal point position depends on input         Ambient operating humidity        10% to 80%
                             type)

   Sampling period           250 ms                                                         Storage temperature               -20 to 60C (with no condensation or
                                                                                                                              icing)
                             Thermocouple: 0.1C/ max. (100  max.) (See note 3.)
   Affect of signal source   Platinum resistance thermometer: 0.4C/ max. (10               Storage humidity                  10% to 80%
   resistance                max.)

   Insulation resistance     20 M min. (at 500 VDC)                                         Altitude                          2,000 m max.

                             2,000 VAC, 50 or 60Hz for 1 min (between terminals with        Weight                            Approx. 100 g
                             different charge)
   Dielectric strength                                                                      Note: A driver must be installed in the personal computer. Refer to
                                                                                                    installation information in the operation manual for the
   Vibration   Malfunction   10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z
   resis-                    directions                                                             Conversion Cable.
   tance
               Destruction   10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in        Communications Specifications
                             X, Y, and Z directions

   Shock       Malfunction 100 m/s2 min., 3 times each in X, Y, and Z directions            Transmission line    RS-485 multipoint
   resis-      Destruction 300 m/s2 min., 3 times each in X, Y, and Z directions            connection method
   tance

               E5CZ          Controller: Approx. 150 g, Mounting Bracket: Approx.           Communications RS-485 (two-wire, half duplex)
               E5CZ-U        10 g
   Weight                    Controller: Approx. 110 g, Mounting Bracket: Approx.           Synchronization      Start-stop synchronization
                             10 g                                                           method

                    E5CZ     Front panel: IP66 (indoor use)                                 Baud rate            1200, 2400, 4800, 9600, 19200, or 38400 bps
   Degree of                 Rear case: IP20, Terminals: IP00
   protection                Front panel: Equivalent to IP50, Rear case: IP20,              Transmission code ASCII
                             Terminals: IP00 (See note 4.)
                    E5CZ-U                                                                  Data length          7 or 8 bits

   Memory protection         Non-volatile memory (number of writes: 1,000,000               Stop bits            1 or 2 bits
                             times)
                                                                                                                 Vertical parity (none, even, odd)
                             Emission Enclosure: EN55011 Group1 Class A                     Error detection      Frame check sequence (FCS) with SYSWAY
                             Emission AC Mains: EN55011 Group1 Class A                                           Block check character (BCC) with CompoWay/F or
                             Immunity ESD: EN61000-4-2 4 kV contact discharge                                    CRC-16 Modbus

                                                    (level 2)                               Flow control         None
                                                    8 kV air discharge (level 3)
                             Immunity RF-interference:                                      Interface            RS-485
                                                    EN61000-4-3 10 V/m
                                                    (80-1000 MHz, 1.4-2.0 GHz amplitude     Retry function       None
                                                    modulated) (level 3)
                                                    10 V/m (900 MHz pulse modulated)        Communications       40 bytes
                             Immunity Conducted Disturbance:                                buffer
   EMC                                              EN61000-4-6 3 V
                                                    (0.15 to 80 MHz) (level 2)                                   0 to 99 ms
                             Immunity Burst: EN61000-4-4 2 kV Power-line (level 3)          Send data wait time  Default: 20 ms
                                                    1 kV I/O signal-line (level 3)
                             Immunity Surge: EN61000-4-5 1kV line to line                   Note: The baud rate, data length, stop bits, and vertical parity can be
                                                    Power line, output line (relay output)          individually set using the Communications Setting Level.
                                                    2 kV line to ground
                                                    Power line, output line (relay output)
                                                    1 kV line to ground
                                                    Input line (communication)
                             Immunity Voltage Dip/Interrupting:
                                                    EN61000-4-11 0.5 cycle, 100% (rated
                                                    voltage)

   Approved standards        UL 61010C-1
                             CSA C22.2 No.1010.1

   Conformed standards       EN61326, EN61010-1, IEC61010-1
                             VDE0106 Part 100 (Finger protection), when the
                             terminal cover is mounted.

8
                                                                                                                                                                 E5CZ/E5CZ-U

Current Transformer (Order Separately)                                                       E54-CT1
                                                                                             Thru-current (Io) vs. Output Voltage (Eo)
Ratings                                                                                      (Reference Values)

Dielectric                                   1,000 VAC for 1 min                             Maximum continuous heater current: 50 A (50/60 Hz)
strength                                                                                     Number of windings: 4002
                                                                                             Winding resistance: 182
Vibration                                    50 Hz, 98 m/s2
resistance

Weight                                       E54-CT1: Approx. 11.5 g, E54-CT3: Approx. 50 g  Output voltage (Eo) V (r.m.s.)  100 V 50 Hz

Accessories Armatures (2)                                                                                                           10                                Distortion
(E54-CT3 only) Plugs (2)                                                                                                             1    1 k                         factor 10%

Heater Burnout and Heater Short Alarms                                                                                       100 mV                                  3%
                                                                                                                                                                 1%
Maximum
heater current                            50 A AC

Input current                             5% FS 1 digit max.                                                               10                        100
indication
accuracy                                                                                                                                               RL = 10

                                          0.1 to 49.9 A (in units of 0.1 A)                                                  1
                                          0.0 A: Heater burnout/Heater short alarm output
Heater burn-                              turns OFF.                                                                         100 V
out alarm set-                            50.0 A: Heater burnout/Heater short alarm output
ting range                                turns ON.                                                                          10
                                          Minimum detection ON time: 190 ms (See note 1.)
                                                                                                                               1          10 100 mA 1        10  100 1,000 A

                                          0.1 to 49.9 A (in units of 0.1 A)                                                                     Thru-current (Io) A (r.m.s.)
                                          0.0 A: Heater burnout/Heater short alarm output
Heater short                              turns ON.                                          E54-CT3
alarm setting                             50.0 A: Heater burnout/Heater short alarm output   Thru-current (Io) vs. Output Voltage (Eo)
range                                     turns OFF.                                         (Reference Values)
                                          Minimum detection OFF time: 190 ms (See note
                                          2.)                                                Maximum continuous heater current: 120 A (50/60 Hz)
                                                                                             (Maximum continuous heater current for an OMRON Temperature
Note: 1. If the ON time of control output 1 is less than 190 ms, heater                      Controller is 50 A.)
            burnout and the heater current will not be measured.                             Number of windings: 4002
                                                                                             Winding resistance: 80.8
        2. If the OFF time of control output 1 is less than 190 ms,
            heater short alarm and the heater current will not be                            Output voltage (Eo) V (r.m.s.)  100 V 50 Hz
                                                                                                                                 10
            measured.                                                                                                              1

Electrical Life Expectancy Curve for                                                                                                                                Distortion
Relays (Reference Values)                                                                                                                  1 k                      factor 10%

                                                                                                                                          500                      3%
                                                                                                                                                                 1%

            Life ( 104 operations)  500                                                                                     100 mV
                                     300                                                                                            10
                                                                                                                                     1
                                     100                                                                                                                100
                                                                                                                                                       50
                                      50
                                      30                                                                                                               RL = 10

                                     10                                                                                      100 V
                                                                                                                                   10
                                     5       E5CZ                                                                                     1   10 100 mA 1        10  100 1,000 A

                                     3       250 VAC, 30 VDC                                                                                     Thru-current (Io) A (r.m.s.)
                                             (resistive load)

                                             cos = 1

                                     1    0  1        2        3  4  5  6

                                                                  Switching current (A)

                                                                                                                                                                                  9
E5CZ/E5CZ-U

External Connections

A voltage output (control output 1) is not electrically insulated from the internal circuits. When using a grounding thermocouple, do not connect
   any of the control output terminals to ground. If the control output terminals are connected to ground, errors will occur in the measured
   temperature values as a result of leakage current.

E5CZ

        Relay output                                   +                 11            6         Alarm output (Relay output)
        250 VAC, 3 A
        (Resistive load)                                        1

                                       Control output 1                                              Alarm output 2  Alarm output (Relay
                                                                                                                     output), 250 VAC, 1 A
        Voltage output                                 -        2        12            7
                                                                                           Alarm output 1, HB alarm/HS (Resistive load)
        12 VDC, 21 mA +                                   A                                alarm/input error
                                                                                       8
        Current output mA                                       3        13

        4 to 20 mA DC - -                        -           B  4        14            9
                                                                                            Input power supply
        0 to 20 mA DC               V

        Load 600  max.                                    B     5        15            10

                                    +            +                                                         100 to 240 VAC

                                    Analog input TC/Pt                                                     24 VAC/DC (no polarity)

                                                 universal input

Option Units                        E53-CZHB                 E53-CZ03                  E53-CZB
                                    Event inputs/            Communications            Event inputs
                   E53-CZH03        CT
                   Communications/
                   CT

             B 11                            11                B 11                                  11
        RS-485                                            RS-485
                                       EV1 12                                              EV1 12
             A 12                   EV2 13                     A 12

        Do not  13                           14              Do not  13                   EV2 13
        use.                                                 use.
                                    CT1
                 14                                          Do not  14                Do not        14
                                             15              use.                      use.
        CT1
                                                             Do not  15                Do not        15
                 15                                          use.                      use.

E5CZ-U

        Relay output                                                            Alarm output (Relay output),

        SPDT 250 VAC, 3 A                                       5    6       7  250 VAC, 1 A (Resistive load)
        (Resistive load) Control output 1
                                                                                    Alarm output 1/
                                                                                    input error
                                                          4                     8
                                                    +                                      Alarm output 2

        Voltage output                              A     3                         9
        12 VDC, 21 mA

                                                    B        2                  10

                                               B                   1 11 Input power supply
                                       +

                                       TC/Pt                                               100 to 240 VAC
                                       universal input                                     24 VAC/DC (no polarity)

        Note: For the Wiring Socket, purchase the P2CF-11 or PG3A-11 separately.

10
                                                                                                                                                          E5CZ/E5CZ-U

Nomenclature

E5CZ
E5CZ-U

The front panel is the same for the E5CZ and E5CZ-U.

                                                                                Temperature unit

                                                               OMRON

                                 Operation indicators                                                                  No. 1 display
                                                                                                                       No. 2 display
                                       Level Key
                                                                                                                           Up Key

                                                                                     Mode Key  Down Key

Dimensions

E5CZ                                                   (84)                                                                                     Panel Cutout
Terminal Models
                        48 48  6                     78                                                 44.8 44.8      Individual Mounting                Group Mounting
                                                                                           58                                                                                                                    +1.0
                                       1.5                                                                                                                                                                         0

                 OMRON

                                                                                                                                                              45                                                       +0.6
                                                                                                                                                                                                                         0

                                                                                                                           60 min.                        Waterproofing is not possible
                                                                                                                                                          when group mounting
                                                                                                                                                          Controllers.

                        Waterproof Packing (Accessory) Mounting Adapter (Accessory)                                                             45  +0.6
                                                                                                                                                      0

                                                       (97)

                        48 48  6                     (91)                                                            48

                                       1.5                                                                                            45  +0.6
                                                                                                                                            0
                                                                                                                                                 Recommended panel thickness is
                 OMRON                                                                                                                            1 to 5 mm.

                                                                                               48.8 58                                           Group mounting is not possible in
                                                                                                                                                  the vertical direction. (Maintain the
                        Waterproof Packing (Accessory) Mounting Adapter (Accessory) Terminal Cover (E53-COV17)                                    specified mounting space between
                                                                                                  (Order separately)                              Controllers.)

                                                    Note: The terminal block cannot be removed.                                                 To mount the Controller so that it is
                                                                                                                                                  waterproof, insert the waterproof
                                                                                                                                                  packing onto the Controller.

                                                                                                                                                 When two or more Controllers are
                                                                                                                                                  mounted, make sure that the
                                                                                                                                                  surrounding temperature does not
                                                                                                                                                  exceed the ambient operating
                                                                                                                                                  temperature given in the
                                                                                                                                                  specifications.

E5CZ-U                                                                                                                                          Panel Cutout
Plug-in Models
                                                                                                                           Individual Mounting            Group Mounting
                                                                                                                                                                                                             +1.0
                                                                                                                                                                                                               0

                                    6                  (90.7)                        14.2

                        48 48                        70.5                                             44.8 44.8

                                                                                                                                                              45                                                   +0.6
                                                                                                                                                                                                                     0

                                                                                                                           60 min.

                                                                                           58

                                                                                                                                                45  +0.6
                                                                                                                                                      0

                                 Mounting Adapter (Accessory)                                           48                            45  +0.6       Recommended panel thickness is
                                                                                                                                            0         1 to 5 mm.

                                       Note: There is no waterproof function for the E5CZ-U.                                                         Group mounting is not possible in
                                                                                                                                                      the vertical direction. (Maintain the
                                                                                                                                                      specified mounting space between
                                                                                                                                                      Controllers.)

                                                                                                                                                    When two or more Controllers are
                                                                                                                                                      mounted, make sure that the
                                                                                                                                                      surrounding temperature does not
                                                                                                                                                      exceed the ambient operating
                                                                                                                                                      temperature given in the
                                                                                                                                                      specifications.

                                                                                                                                                                                                                       11
E5CZ/E5CZ-U                                                                                                                                 (2,100)                 1,765
                                                                                                                      LED indicator (SD)
Accessories
                                                                                                                                       LED indicator (RD)                            Serial connector
USB-Serial Conversion Cable (Order Separately)

E58-CIFQ1

                                                                                                                 250

                                                                                    USB connector (type A plug)

Terminal Cover (Order Separately)                                                                                     Waterproof Packing

E53-COV17                 48                                                                                          Y92S-29 (for DIN 48 48)

                    48.8                                                                                                                        Order the Waterproof Packing separately if it becomes lost or
                                                                                                                                                damaged.
                         22
                                                                                                                                                The Waterproof Packing can be used to achieve an IP66
                         9.1                                                                                                                    (indoor use) degree of protection.

           Note: The E53-COV10 cannot be used.                                                                                                  (Deterioration, shrinking, or hardening of the waterproof
                                                                                                                                                packing may occur depending on the operating environment.
                                                                                                                                                Therefore, periodic replacement is recommended to ensure
                                                                                                                                                the level of waterproofing specified in IP66 (indoor use). The
                                                                                                                                                time for periodic replacement depends on the operating envi-
                                                                                                                                                ronment. Be sure to confirm this point at your site. Consider
                                                                                                                                                one year a rough standard. OMRON shall not be liable for
                                                                                                                                                the level of water resistance if the customer does not perform
                                                                                                                                                periodic replacement.)

                                                                                                                                                The Waterproof Packing does not need to be attached if a
                                                                                                                                                waterproof structure is not required.

                                                                                                                                             Note: There is no waterproof function for the E5CZ-U.

    Unit Labels (Order Separately)  11.8                                                                              Current Transformers (Order Separately)
                                                4.8
    Y92S-L1 Type

                                                                                                                      E54-CT1                                   21                               2.8

                                                                                                                                                                15         5.8 dia.

                                                                                                                                                                                                      7.5

                                                                                                                                                     25 3                                10.5
                                                                                                                                                            10  40

                                                                                                                                                                                  Two, 3.5 dia.

                                                                                                                                                                30

E54-CT3                                                      2.36 dia.     E54-CT3 Accessory                                           Connection Example
                          30                                                 Armature
                                                                                                                                                                Armature
                                           12 dia.
                                                                                                                                                     Plug
                                                                        9

                                                                           Approx. 3 dia.                                                                                  Lead

           40 40

                                                   Two, M3 (depth: 4)       Plug                                                  18
           15                                                                                                                  (22)
                                                                           Approx. 6 dia.
                                   30

12
                                                                                                                                                                                                E5CZ/E5CZ-U

Adapter (Order Separately)

Note: 1. Use this Adapter when the panel has already been prepared for the E5B@.
        2. Only black is available.

Y92F-45                                                                                                                                                                    Fixture (Accessory)

                                                                                                                       4.7                         76

                                                                                                                                                   69.6 to 77.6

                              72 72

                                                                                                                                                                           67 67 87

Mounted to E5CZ               72 72                                                                                          Panel (1 to 8 mm)
                                                                                                            48 48

                                                                                                                       2.2                    4.7

                                                                                                                                                   77.3 (to back of E5CZ)

E5CZ-U Wiring Socket (Order Separately)

Front-connecting Socket

P2CF-11          Eleven, M3.5 7.5                                                                      3             4.5                    Terminal Layout/Internal Connections
                                                                                                                                                                (Top View)
                 sems screws                                                                        7.8
                                                                                                                                                                 8765
                                                                                                                                                                              4                  Mounting Holes

                                                                                                                                                                                                Two, 4.5 dia. mounting holes

                 70 max.                                                                                                                35.4

                                                                                                    Two,                                                         9          3                                          400.2
                                                                                                    4.5-dia.
                                                                                                    holes                                                        10 11 1 2             Note: Can also be mounted to a DIN track.

                         4    50 max.

                                                                                                            31.2 max.

Note: A model with finger protection (P2CF-11-E) is also available.

Back-connecting Socket                                                                                                                4 73         Terminal Layout/Internal Connections
P3GA-11                                                                                                                                                            (Bottom View)
                                                                                                                              25.6
                                                                                           27 dia.                                                                   5 678
                                                                                                         4.5 16.3 6.2                                               4
                                                                            45                                                    8.7
                                                                                                                                                                    3          9
                                                                                              45
                                                                                                                                                                    2 1 11 10

                                                                                                                                                       6

Note: 1. Using any other sockets will adversely affect accuracy. Use only the specified sockets.
        2. A Protective Cover for finger protection (Y92A-48G) is also available.

                                                                                                                                                                                                                              13
    Digital Temperature Controllers

    E5AZ/E5EZ (96 96 mm and 48 96 mm)

These Best-selling General-
purpose Temperature Controllers
Are Now Even Better.

Controllers now available with analog inputs.       96 96 mm                             48 96 mm
Faster sampling at 250 ms.                              E5AZ                                   E5EZ
Transfer output provided for easy output to
                                                      Note: Refer to page 30 for information on changes in comparison to
  recorders.                                                  previous models.
Models available with a loop break alarm (LBA) and

  heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the

  models with communications.
USB-Serial conversion cable is available.

Note: Refer to Precautions on page 33.

Main I/O Functions

                                        E5AZ          E5EZ

    Event Inputs                                                            2-level Display: PV and SV
    None
    Two

    Sensor Inputs                                                           4-digit Display
    Universal thermocouple/Pt inputs
                                                      Alarm Outputs                           Auto/manual switching
     (Models with temperature inputs)                  Three                                 Models also available with
    Analog current/voltage inputs
                                                                                               RS-485 or RS-232C
     (Models with analog inputs)                                                               communications

    Indication Accuracy                 Control Output 1
    Thermocouple input: 0.5% of PV    Relay output
    Pt input: 0.5% of PV             Voltage output (for driving SSR)
    Analog input: 0.5% FS             Current output

    Sampling Period
    250 ms

14
Model Number Structure                                                                       E5AZ/E5EZ

Model Number Legend                                      Option Units

Controllers                                              E53-AZ@
                                                                     12
E5AZ/EZ-@3@@@@                                           1. Applicable Controller
                     1 23 4 5 6
1. Control Output 1                                         AZ: E5AZ/E5EZ
                                                         2. Function
   R: Relay output
   Q: Voltage output (for driving SSR)                      01: RS-232C communications
   C: Current output                                        03: RS-485 communications
2. Number of Alarms                                         B: Two event inputs
   3: Three alarms
3. Heater Burnout/Heater Short
   Blank: None
   H: Heater burnout/Heater short detection (CT1)
4. Option
   Blank: None
   M: Option Unit can be mounted.
5. Input Type
   T: Thermocouple, infrared sensor/platinum resistance

       thermometer
   L: Analog current/voltage input
6. Power Supply Voltage
   Blank: 100 to 240 VAC
   D: 24 VAC/VDC

Ordering Information

Controllers with Terminal Blocks

                                                                                 Functions

Size  Power supply               Input type     Alarm    Control output      Heater  Mounting      Previous model     New model
          voltage                               output                      burnout    option
                              Thermocouple               Relay output                   units  E5AZ-R3              E5AZ-R3T
                              or Resistance     3                                              E5AZ-A3 + E53-AZR
                              thermometer                Voltage output     No       No        E5AZ-Q3              E5AZ-Q3T
                                                3        (for driving SSR)                     E5AZ-A3 + E53-AZQ
                              Analog (current/  3                           No       No        E5AZ-C3              E5AZ-C3T
                              voltage)          3        Current output                        E5AZ-A3 + E53-AZC    E5AZ-R3MT
                                                                            No       No        E5AZ-R3 + E53-AZM    E5AZ-Q3MT
                              Thermocouple               Relay output                                               E5AZ-C3MT
                              or Resistance              Voltage output     No       Yes       E5AZ-Q3 + E53-AZM    E5AZ-R3HMT
                              thermometer                (for driving SSR)
                  100 to                                 Current output     No       Yes       E5AZ-C3 + E53-AZM    E5AZ-Q3HMT
                  240 VAC     Analog (current/                                                 E5AZ-R3 + E53-AZM +  E5AZ-R3HML
                              voltage)                   Relay output       No       Yes       E53-AZH              E5AZ-Q3HML
1/4 DIN                                                                                        E5AZ-Q3 + E53-AZM +  E5AZ-C3ML
96 96 78                                             Voltage output     Yes (CT1) Yes      E53-AZH              E5AZ-R3MTD
(W H D)                                              (for driving SSR)                     None                 E5AZ-Q3MTD
                                                         Relay output       Yes (CT1) Yes                           E5AZ-C3MTD
                  24 VAC/VDC                             Voltage output                        None                 E5AZ-R3HMTD
                                                         (for driving SSR)  Yes (CT1) Yes                           E5AZ-Q3HMTD
                                                         Current output                        None                 E5AZ-R3HMLD
                                                         Relay output       Yes (CT1) Yes      None                 E5AZ-Q3HMLD
                                                         Voltage output                                             E5AZ-C3MLD
                                                         (for driving SSR)  No       Yes       None
                                                         Current output
                                                         Relay output       No       Yes       None
                                                         Voltage output                        None
                                                         Relay output       No       Yes       None
                                                         Voltage output                        None
                                                         (for driving SSR)  No       Yes
                                                         Current output                        None
                                                                            Yes (CT1) Yes
                                                                                               None
                                                                            Yes (CT1) Yes

                                                                            Yes (CT1) Yes

                                                                            Yes (CT1) Yes

                                                                            ---      Yes

                                                                                                                    15
E5AZ/E5EZ

Controllers with Terminal Blocks

                                                                                     Functions

    Size  Power supply                Input type    Alarm   Control output          Heater Mounting          Previous model         New model
              voltage                               output                          burnout option
                                  Thermocouple or           Relay output                                                          E5EZ-R3T
                                  Resistance        3                                                 units
                                  thermometer               Voltage output                                                        E5EZ-Q3T
                                                    3       (for driving SSR)    No  No                      E5EZ-R3
                                  Analog (current/  3                                                        E5EZ-A3 + E53-AZR    E5EZ-C3T
                                  voltage)          3       Current output                                                        E5EZ-R3MT
                                                                                 No  No                      E5EZ-Q3              E5EZ-Q3MT
                                  Thermocouple or           Relay output                                     E5EZ-A3 + E53-AZQ    E5EZ-C3MT
                                  Resistance                Voltage output                                                        E5EZ-R3HMT
                                  thermometer               (for driving SSR)    No  No                      E5EZ-C3
                                                            Current output                                   E5EZ-A3 + E53-AZC    E5EZ-Q3HMT
                                  Analog (current/                                                                                E5EZ-R3HML
                                  voltage)                  Relay output         No  Yes                     E5EZ-R3 + E53-AZM    E5EZ-Q3HML
                                                                                                                                  E5EZ-C3ML
                      100 to                                Voltage output       No  Yes                     E5EZ-Q3 + E53-AZM    E5EZ-R3MTD
                      240 VAC                               (for driving SSR)                                                     E5EZ-Q3MTD
                                                            Relay output         No  Yes                     E5EZ-C3 + E53-AZM    E5EZ-C3MTD
    1/8 DIN                                                 Voltage output                                                        E5EZ-R3HMTD
    48 96 78                                            (for driving SSR)    Yes (CT1) Yes               E5EZ-R3 + E53-AZM +  E5EZ-Q3HMTD
    (W H D)                                             Current output                                   E53-AZH              E5EZ-R3HMLD
                                                            Relay output         Yes (CT1) Yes                                    E5EZ-Q3HMLD
                      24 VAC/VDC                            Voltage output       Yes (CT1) Yes               E5EZ-Q3 + E53-AZM +  E5EZ-C3MLD
                                                            (for driving SSR)                                E53-AZH
                                                            Current output
                                                            Relay output                                     None
                                                            Voltage output
                                                            Relay output         Yes (CT1) Yes               None
                                                            Voltage output
                                                            (for driving SSR)    No  Yes                     None
                                                            Current output
                                                                                 No  Yes                     None

                                                                                 No  Yes                     None

                                                                                 No  Yes                     None
                                                                                                             None
                                                                                 Yes (CT1) Yes               None
                                                                                                             None
                                                                                 Yes (CT1) Yes

                                                                                 Yes (CT1) Yes

                                                                                 Yes (CT1) Yes               None

                                                                                 -   Yes                     None

Option Units                                  Function                    Model
                                  RS-232C Communications    E53-AZ01
               Name               RS-485 Communications     E53-AZ03
Communications Unit              Event input               E53-AZB

Event Input Unit

Accessories (Order Separately)

USB-Serial Conversion Cable

                                         Model      Model
                                      E58-CIFQ1  E53-COV11

Terminal Cover                                      Model
                                                   Y92S-P4
      Connectable models                           Y92S-P5
                 E5AZ
                 E5EZ

Waterproof Packing

      Connectable models
                 E5AZ
                 E5EZ

Current Transformers (CTs)                        Model
                                                 E54-CT1
           Hole diameter                         E54-CT3
                5.8 dia.
               12.0 dia.

16
                                                                                                                       E5AZ/E5EZ

Specifications

Ratings

Power supply voltage                  100 to 240 VAC, 50/60 Hz                     24 VAC, 50/60 Hz or 24 VDC
Operating voltage range
Power consumption             85% to 110% of rated supply voltage

                              8.5 VA                                               6 VA (24 VAC)/4 W (24 VDC)

Sensor input                  Models with temperature inputs
                                  Thermocouple: K, J, T, E, L, U, N, R, S, or B
                                  Platinum resistance thermometer: Pt100 or JPt100
                                  Infrared temperature sensor: 10 to 70C, 60 to 120C, 115 to 165C, or 140 to 260C
                                  Voltage input: 0 to 50 mV

                              Models with analog inputs
                                  Current input: 4 to 20 mA or 0 to 20 mA
                                  Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

Input impedance               Current input: 150 , Voltage input: 1 M (Use a 1:1 connection when connecting the ES2-HB.)

              Relay output    SPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V,
                              10 mA

Control       Voltage output  Output voltage: 12 VDC +15%/-20% (PNP), max. load current: 40 mA, with short-circuit protection circuit
output        (for driving
              SSR)
                              4 to 20 mA DC/0 to 20 mA DC, load: 600  max., resolution: approx. 2,700
              Current output  SPST-NO, 250 VAC, 2 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V,
                              10 mA
Alarm output                  ON: 1 k max., OFF: 100 k min.

Event input   Contact input   ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.

              Non-contact     Outflow current: Approx. 7 mA per point
              input           ON/OFF control or 2-PID control (with auto-tuning)
                              Digital setting using front panel keys
Control method                11-segment digital display and individual indicators (7-segments displays also possible)
Setting method                Character height: E5AZ: PV: 15 mm, SV: 9.5 mm

Indication method                                     E5EZ: PV: 14 mm, SV: 9.5 mm
                              Manual output, heating/cooling control, transfer output (on some models), loop break alarm, multi SP, MV
Other functions               limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, etc.

Ambient operating             -10 to 55C (with no icing or condensation)
temperature
Ambient operating humidity    25% to 85%
Storage temperature           -25 to 65C (with no icing or condensation)

                                                                                                                                          17
E5AZ/E5EZ

Input Ranges

Thermocouples/Platinum Resistance Thermometers (Universal Inputs)

                        Input              Platinum resistance                                                             Thermocouple                                                   Infrared temperature       Analog
                        Type                    thermometer                                                                                                                                        sensor             input

                        Name               Pt100         JPt100                K                          J             T            EL              U         N        R     S  B     10 to  60 to  115 to  140 to  0 to 50 mV
                                                                                                                                                                                       70C   120C  165C   260C

                        1800                                                                                                                                                     1800                                Usable in
                        1700                                                                                                                                                                                         the
                        1600                                                                                                                                         1700  1700                                      following
                        1500                                                                                                                                                                                         ranges by
                        1400                                             1300                                                                                  1300                                                  scaling:
                        1300                                                                         850                                                                                                             -1999 to
Temperature range (C)  1200                                                                                                                                                                                         9999 or
                        1100                                                                                                                                                                                         -199.9 to
                        1000                                                                                                                                                                                         999.9

                                      850                                                                                                 850

                         900
                         800

                        700                                                                                                       600

                        600                500.0         500.0                    500.0

                        500                                                                                  400.0 400     400.0                400     400.0

                        400                                                                                                                                                                                  260

                        300                                                                                                                                                                   120    165

                        200                       100.0          100.0                                                                                                                 90

                        100                                                                                                                                                      100

                               0                  0.0            0.0                                                              0                                  0     0           0      0      0       0

                        -100.0                                                    -20.0 -100 -20.0                                        -100

                        -200.0    -200 -199.9            -199.9          -200                                -200 -199.9                        -200 -199.9 -200

    Setting                       0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    number

The applicable standards for the input types                                                U: Cu-CuNi, DIN 43710-1985                                                           Shaded settings are the default settings.
are as follows:                                                                             Pt100: IEC 751
                                                                                            JPt100: JIS C 1604-1989, JIS C 1606-1989
K, J, T, E, N, R, S, B: IEC 584-1

L: Fe-CuNi, DIN 43710-1985

Models with Analog Inputs

         Input Type                                      Current                                                Voltage
    Input specification
    Setting range                                 4 to 20mA 0 to 20 mA 1 to 5 V 0 to 5 V 0 to 10 V

    Setting number                                Usable in the following ranges by scaling:

                                                  -1999 to 9999, -199.9 to 999.9, -19.99 to 99.99 or
                                                  -1.999 to 9.999

                                                  0                   1                  2                   3                         4                Shaded settings are the default settings.

18
                                                                                                                             E5AZ/E5EZ

Alarm Types

Select alarm types out of the 12 alarm types listed in the following table.

                                    Alarm output operation                   Note: 1. With set values 1, 4 and 5, the upper and lower limit values
                                                                                         can be set independently for each alarm type, and are
Set value      Alarm type    When X is posi- When X is nega-                            expressed as "L" and "H."

0           Alarm function          tive                      tive                   2. Set value: 1, Upper- and lower-limit alarm
1           OFF
(See note                     Output OFF                                     Case 1           Case 2                         Case 3 (Always ON)
1.)
            Upper- and lower- ON       LH                (See note 2.)         L H SP         SP L H                           H SP L                            H<0, L<0
2                                                                                                                            H L SP
            limit             OFF      SP                                    H<0, L>0           H>0, L<0                                                         H<0, L>0
3                                                                             |H| < |L|          |H| > |L|                                                        |H|  |L|
                                                                                                                                                                 H>0, L<0
4           Upper limit       ON            X            ON   X                                                                                          SP H L   |H|  |L|
(See note   Lower limit       OFF       SP               OFF   SP
1.)                                    X                           X         3. Set value: 4, Upper- and lower-limit range
                              ON        SP               ON    SP
                              OFF                        OFF                 Case 1           Case 2                         Case 3 (Always ON)                  H<0, L<0

            Upper- and lower- ON       LH                (See note 3.)              L H SP      SP L H                              H SP L                       H<0, L>0
                                                                                 H<0, L>0         H>0, L<0                       H L SP                           |H|  |L|
            limit range       OFF                                                  |H| < |L|        |H| > |L|
                                                  SP
                                                                                                                                                                 H>0, L<0

5           Upper- and lower- ON       LH                                                                                    SP H L                              |H|  |L|
(See note
1.)         limit with standby OFF                       (See note 4.)       4. Set value: 5, Upper- and lower-limit with standby sequence
6
            sequence                   SP                                    For Upper- and Lower-Limit Alarm Described Above
7
                              (See note 5.)                                  Case 1 and 2
8                                                                              Always OFF when the upper-limit and lower-limit
            Upper-limit with  ON                      X  ON   X
9                                                        OFF   SP              hysteresis overlaps.
            standby sequence OFF       SP                          X
10                                                       ON    SP
            Lower-limit with  ON       X                 OFF    X             Case 3: Always OFF
11                                                                    0
            standby sequence OFF       SP                ON     X                    5. Set value: 5, Upper- and lower-limit with standby sequence
12                                                       OFF          0                  Always OFF when the upper-limit and lower-limit hysteresis
(See note   Absolute-value    ON         X                      X
6.)         upper-limit       OFF   0                    ON           0                  overlaps.
                                                         OFF
            Absolute-value    ON         X                      X                    6. Set value: 12, LBA (loop break alarm) can be set only for
            lower-limit       OFF   0                    ON           0                  alarm 1 type.
                                                         OFF
                                                                             Set the alarm types for alarms 1 to3 independently in the initialsetting
                                                         ON
            Absolute-value                               OFF                 level. The default setting is 2 (upper limit).

            upper-limit with  ON          X
                              OFF
            standby sequence        0

            Absolute-value    ON          X
                              OFF
            lower-limit with        0

            standby sequence

            LBA (for alarm 1  ---
            type only)

                                                                                                                                                                           19
E5AZ/E5EZ

Characteristics                                                                                    5. When using the E53-AZB, E53-AZ01, or E53-AZ03 Option
                                                                                                       Unit with the E5AZ-@3@M@@ to satisfy the immunity burst
    Indication accuracy      Thermocouple: (See note 1.)                                               requirements in the EN 61326 standard, always connect a
                             (0.5% of indicated value or 1C, whichever is greater) 1               ZCAT2035-0930 Clamp Filter (manufactured by TDK) to the
                             digit max.                                                                cable for terminals 11, 12, and 13.
                             Platinum resistance thermometer:
                             (0.5% of indicated value or 1C, whichever is greater) 1           USB-Serial Conversion Cable
                             digit max.
                             Analog input: 0.5% FS 1 digit max.
                             CT input: 5% FS 1 digit max.

    Influence of tempera-    R, S, and B thermocouple inputs:                                      Applicable OS                     Windows 2000/XP/Vista
    ture (See note 2.)       (1% of PV or 10C, whichever is greater) 1 digit max.
                             Other thermocouple inputs:                                            Applicable software               Thermo Mini
    Influence of voltage     (1% of PV or 4C, whichever is greater) 1 digit max.
    (See note 2.)            *10C for -100C or less for K sensors                               Applicable models                 E5CZ/E5CZ-U/E5AZ/E5EZ
                             Platinum resistance thermometer inputs:
                             (1% of PV or 2C, whichever is greater) 1 digit max.               USB interface standard            Conforms to USB Specification 1.1.
                             Analog inputs:
                             (1% of FS) 1 digit max.                                             DTE speed                         38400 bps

    Hysteresis               Models with thermocouple/platinum resistance thermometer              Connector specifications          Computer: USB (type A plug)
                             input (universal input):                                                                                Temperature Controller: Setup Tool port
                                                                                                                                     (on bottom of Controller)
                                0.1 to 999.9 EU (in units of 0.1 EU) (See note 3.)
                             Models with analog input:                                                                               Bus power (Supplied from USB host
                                                                                                                                     controller.)
                                0.01 to 99.99% FS (in units of 0.01% FS)

                             Models with thermocouple/platinum resistance thermometer              Power supply
                             input (universal input):
    Proportional band (P)                                                                          Power supply voltage              5 VDC
                                0.1 to 999.9 EU (in units of 0.1 EU) (See note 3.)
                             Models with analog input:                                             Current consumption               70 mA

                                0.1 to 999.9% FS (in units of 0.1% FS)

    Integral time (I)        0 to 3999 s (in units of 1 s)                                         Ambient operating temperature 0 to 55C (with no condensation or icing)

    Derivative time (D)      0 to 3999 s (in units of 1 s)                                         Ambient operating humidity        10% to 80%

    Control period           0.5, 1 to 99 s (in units of 1 s)                                                                        -20 to 60C (with no condensation or
                                                                                                                                     icing)
    Manual reset value       0.0 to 100.0% (in units of 0.1%)                                      Storage temperature

    Alarm setting range      -1999 to 9999 (decimal point position depends on input type)          Storage humidity                  10% to 80%

    Sampling period          250 ms                                                                Altitude                          2,000 m max.

    Affect of signal source Thermocouple: 0.1C/ max. (100  max.) (See note 4.)                    Weight                            Approx. 100 g
                             Platinum resistance thermometer: 0.4C/ max. (10  max.)
    resistance                                                                                     Note: A driver must be installed in the personal computer. Refer to
                                                                                                           installation information in the operation manual for the
    Insulation resistance 20 M min. (at 500 VDC)
                                                                                                           Conversion Cable.
    Dielectric strength      2,000 VAC, 50 or 60 Hz for 1 min (between terminals with
                             different charge)

    Vibration Malfunction 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions           Communications Specifications

    resis-      Destruction  10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y,         Transmission line con- RS-485 multipoint
    tance                    and Z directions

    Shock       Malfunction 100 m/s2 min., 3 times each in X, Y, and Z directions                  nection method          RS-232C
    resis-      Destruction 300 m/s2 min., 3 times each in X, Y, and Z directions
    tance                                                                                          Communications          RS-485 (two-wire, half duplex), RS-232C

    Weight      E5AZ         Controller: Approx. 300 g, Mounting Bracket: Approx. 100 g            Synchronization         Start-stop synchronization
                E5EZ         Controller: Approx. 250 g, Mounting Bracket: Approx. 100 g            method

                             Front panel: IP66 (indoor use),                                       Baud rate               1200, 2400, 4800, 9600, 19200, or 38400 bps
                             Rear case: IP20, Terminals: IP00
    Degree of protection                                                                           Transmission code       ASCII

    Memory protection        Non-volatile memory (number of writes: 1,000,000 times)               Data length (See note.) 7 or 8 bits

                             Emission Enclosure: EN55011 Group1 Class A                            Stop bits (See note.) 1 or 2 bits
                             Emission AC Mains: EN55011 Group1 Class A
                             Immunity ESD: EN61000-4-2 4 kV contact discharge (level               Error detection         Vertical parity (none, even, odd)
                                                                                                                           Frame check sequence (FCS) with SYSWAY
                                                     2)                                                                    Block check character (BCC) with CompoWay/F or
                                                     8 kV air discharge (level 3)                                          CRC-16 Modbus
                             Immunity RF-interference:
                                                     EN61000-4-3 10 V/m                            Flow control            None
                                                     (80-1000 MHz, 1.4-2.0 GHz amplitude
                                                     modulated) (level 3)                          Interface               RS-485, RS-232C
                                                     10 V/m (900 MHz pulse modulated)
    EMC                      Immunity Conducted Disturbance:                                       Retry function          None
                                                     EN61000-4-6 3 V
                                                     (0.15 to 80 MHz) (level 2)                    Communications          40 bytes
                             Immunity Burst: EN61000-4-4 2 kV Power-line (level 3)                 buffer
                                                     1 kV I/O signal-line (level 3) (See note 5.)
                             Immunity Surge: EN61000-4-5 1kV line to line                          Send data wait time     0 to 99 ms
                                                     Power line, output line (relay output)                                Default: 20 ms
                                                     2 kV line to ground
                                                     Power line, output line (relay output)        Note: The baud rate, data length, stop bits, and vertical parity can be
                                                     1 kV line to ground                                   individually set using the Communications Setting Level.
                                                     Input line (communication)
                             Immunity Voltage Dip/Interrupting:
                                                     EN61000-4-11 0.5 cycle, 100% (rated
                                                     voltage)

    Approved standards       UL 61010C-1                                                           Current Transformer (Order Separately)
                             CSA C22.2 No.1010.1
                                                                                                   Ratings
    Conformed standards      EN61326, EN61010-1, IEC61010-1
                             VDE0106 Part 100 (Finger protection), when the terminal
                             cover is mounted.                                                     Dielectric strength 1,000 VAC for 1 min

Note: 1. The indication accuracy of K thermocouples in the -200 to                                 Vibration             50 Hz, 98 m/s2
            1300C range, T and N thermocouples at a temperature of                                resistance

            -100C max., and U and L thermocouples at any                                          Weight                E54-CT1: Approx. 11.5 g, E54-CT3: Approx.
                                                                                                                         50 g
            temperature is 2C 1 digit maximum. The indication

            accuracy of the B thermocouple at a temperature of 400C

            max. is not specified. The indication accuracy of the R and                            Accessories           Armatures (2)
            S thermocouples at a temperature of 200C max. is 3C 1                              (E54-CT3 only)        Plugs (2)

                digit max.

            2. Conditions: Ambient temperature: -10C to 23C to 55C,
                Voltage range: -15% to +10% of rated voltage

            3. "EU" stands for Engineering Unit and is used as the unit
                after scaling. For a temperature sensor, the EU is C or F.

            4. B, R, and S sensors: 0.2C/ max. (100  max.)

20
                                                                                                                                                    E5AZ/E5EZ

Heater Burnout and Heater Short Alarms                                          E54-CT1
                                                                                Thru-current (Io) vs. Output Voltage (Eo)
Maximum                       50 A AC                                           (Reference Values)
heater current
                                                                                Maximum continuous heater current: 50 A (50/60 Hz)
Input current                 5% FS 1 digit max.                              Number of windings: 4002
indication                                                                      Winding resistance: 182
accuracy

                              0.1 to 49.9 A (in units of 0.1 A)                 Output voltage (Eo) V (r.m.s.)  100 V 50 Hz
                              0.0 A: Heater burnout/Heater short alarm output
Heater burn-                  turns OFF.                                                                             10                                 Distortion
out alarm                     50.0 A: Heater burnout/Heater short alarm output                                        1      1 k                        factor 10%
setting range                 turns ON.
                              Minimum detection ON time: 190 ms (See note 1.)                                 100 mV                                    3%
                                                                                                                                                    1%
                              0.1 to 49.9 A (in units of 0.1 A)
Heater short                  0.0 A: Heater burnout/Heater short alarm output                                   10                        100
alarm setting                 turns ON.
range                         50.0 A: Heater burnout/Heater short alarm output
                              turns OFF.
                              Minimum detection OFF time: 190 ms (See note                                      1                         RL = 10
                              2.)

Note: 1. If the ON time of control output 1 is less than 190 ms, heater                                         100 V
            burnout detection and the heater current will not be
                                                                                                                101          10 100 mA 1        10  1001,000 A
            measured.

        2. If the OFF time of control output 1 is less than 190 ms,
            heater short alarm and the heater current will not be

            measured.

Electrical Life Expectancy Curve for                                                                                                Thru-current (Io) A (r.m.s.)
Relays (Reference Values)
                                                                                E54-CT3
Life ( 104 operations)  500                                                    Thru-current (Io) vs. Output Voltage (Eo)
                         300                                                    (Reference Values)

                         100              E5EZ                                  Maximum continuous heater current: 120 A (50/60 Hz)
                                                                                (Maximum continuous heater current for an OMRON Temperature
                                          250 VAC, 30 VDC                       Controller is 50 A.)
                                                                                Number of windings: 4002
                                          (resistive load)                      Winding resistance: 80.8

                         50               cos = 1

                         30                                                     Output voltage (Eo) V (r.m.s.)  100 V 50 Hz
                                                                                                                    10
                         10                                                                                                                            Distortion
                          5                                                                                           1                                factor 10%
                          3                                                                                                   1 k
                                                                                                                             500                      3%
                                                                                                                                                    1%

                         1    0  1     2  3         4       5  6                                              100 mV
                                                                                                                     10
                                                    Switching current (A)                                             1                    100
                                                                                                                                          50

                                                                                                                                          RL = 10

                                                                                                                100 V       10 100 mA 1        10  1001,000 A
                                                                                                                     10
                                                                                                                         1

                                                                                                                                    Thru-current (Io) A (r.m.s.)

                                                                                                                                                                    21
E5AZ/E5EZ

External Connections

The voltage output for control output 1 is not electrically insulated from the internal circuits. When using a grounding thermocouple, do not
   connect any of the control output terminals to ground. If the control output terminals are connected to ground, errors will occur in the measured
   temperature values as a result of leakage current.

E5AZ/E5EZ

                                              Option Units  E53-AZB             E53-AZ01           E53-AZ03
                                                            Event input         RS-232C             RS-485
                                                                                                           B(+)
100 to 240 VAC                                             +               EV1     SD
24 VAC/DC (no polarity) Input power supply                                                                 A(-)
                                              EV2
Relay output 250 VAC,                                                      EV2     RD                      Do not use
5 A (Resistive load)                                EV1 +
                                  +
Voltage output                                                                     SG
12 VDC, 40 mA             Control output 1
                                              One CT
Current output                    -
4 to 20 mA DC                                        CT1
0 to 20 mA DC               Alarm output 3
Load 600  max.                                Do not use
                            Alarm output 2
Alarm output                                  Do not use
(Relay output),
250 VAC, 2 A
(Resistive load)

                                                            A Pt                              +

                                              TC-           B                   -  mA

                          Alarm output 1,                                       V    -
                          HB alarm/HS
                          alarm/ input                             B                 +
                          error
                                                 +                              Analog input

                                              TC/Pt universal input

Nomenclature

                                    E5AZ                                                                  E5EZ

      Temperature unit    OMRON                                            Operation indicators    OMRON
    Operation indicators                                                     Temperature unit
                                                            No. 1 display

                                                                                                                       No. 1 display
                                                                                                                       No. 2 display

    Level Key                                               No. 2 display  Operation indicators
                                                             Up Key                      Mode Key

                          Mode Key  Down Key

                                                                                Level Key          Down Key            Up Key

22
Dimensions                                                                                                           E5AZ/E5EZ

E5AZ                                                                                                                 91
                                                                                                                                                     91
            96  11.2

                                                                             78

                                                                   2

                96 112

                Waterproof Packing                                    Mounting Bracket
                (Accessory)                                           (Accessory)

            96  11.2

                                                                             84.5                               91

                                                                   2

                96 112                                                                                                                                                   92.5

                Waterproof Packing                                    Mounting Bracket  Terminal Cover (E53-COV11)
                (Accessory)                                           (Accessory)       (Order separately)

                                                                                          Crimp terminal size: M3.5

                                                                                                  Panel Cutout

                                                                             Individual Mounting                Group Mounting
                                                                                                                                                                   +1.0
                                                                                        92+00.8                                                                      0

                                                                                                                                                                         92+00.8

Note: To remove the Controller from the case, loosen the screw at                                          Waterproofing is not possible when
        the bottom of the front panel with a screwdriver while                                             group mounting Controllers.

        pressing down on the hook at the top of the front panel.

                                                                   120 min.

                                                                                                  92+00.8   Recommended panel thickness is 1 to
                                                                                                             8 mm.

                                                                                                            Group mounting is not possible in the
                                                                                                             vertical direction. (Maintain the
                                                                                                             specified mounting space between
                                                                                                             Controllers.)

                                                                                                            To mount the Controller so that it is
                                                                                                             waterproof, insert the waterproof
                                                                                                             packing onto the Controller.

                                                                                                            When two or more Controllers are
                                                                                                             mounted, make sure that the
                                                                                                             surrounding temperature does not
                                                                                                             exceed the ambient operating
                                                                                                             temperature given in the
                                                                                                             specifications.

                                                                                                                                                                                  23
E5AZ/E5EZ

E5EZ
Terminal Models

                         11.2

                                                                       78                          44
                                                                                                                       91
                 48                         2

                     96  112

                     Waterproof Packing        Mounting Bracket
                     (Accessory)               (Accessory)

                         11.2

                 48                                                    84.5                        44
                                                                                                                    92.5
                                         2

                     96  112

                     Waterproof Packing                                Mounting Bracket  Terminal Cover (E53-COV11)
                     (Accessory)                                       (Accessory)       (Order separately)

                                                                                           Crimp terminal size: M3.5

                                                                                                   Panel Cutout

                                                                                         Individual Mounting                   Group Mounting
                                                                                                                                                                                  +1.0
                                                                                                      45+00.6                                                                       0

                                                                                                                                                92+00.8

    Note: To remove the Controller from the case, loosen the screw                       120 min.                              Waterproofing is not possible when
            at the bottom of the front panel with a screwdriver while                                                          group mounting Controllers.

            pressing down on the hook at the top of the front panel.

                                                                                                                               Recommended panel thickness is 1 to
                                                                                                                               8 mm.
                                                                                                                               Group mounting is not possible in the
                                                                                                                               vertical direction. (Maintain the
                                                                                                                               specified mounting space between
                                                                                                                      92+00.8  Controllers.)

                                                                                                                               To mount the Controller so that it is
                                                                                                                               waterproof, insert the waterproof
                                                                                                                               packing onto the Controller.
                                                                                                                               When two or more Controllers are
                                                                                                                               mounted, make sure that the
                                                                                                                               surrounding temperature does not
                                                                                                                               exceed the ambient operating
                                                                                                                               temperature given in the
                                                                                                                               specifications.

24
                                                                                                                                                                           E5AZ/E5EZ

Accessories                                                                                                                                 (2,100)                 1,765
                                                                                                                      LED indicator (SD)
USB-Serial Conversion Cable (Order Separately)
                                                                                                                                            LED indicator (RD)                       Serial connector
E58-CIFQ1

                                                                                                                 250

                                                                                    USB connector (type A plug)

Terminal Covers                                                         13                                            Waterproof Packing                        Y92S-P5 (for DIN 48 96)
                                                                               6.5 dia.
E53-COV11                                                                                                             Y92S-P4 (for DIN 96 96)
(Two Covers provided.)
(Order Separately)

                            92.3

                                                           10.5         6.5                                           Order the Waterproof Packing separately if it becomes lost or damaged.
                                                                     8
                                                                               11.8                                   The Waterproof Packing can be used to achieve an IP66 (indoor use) degree
Unit Labels (Order Separately)                                                              4.8                       of protection.
   Y92S-L1 Type
                                                                                                                      (Deterioration, shrinking, or hardening of the waterproof packing may occur
                                                                                                                      depending on the operating environment. Therefore, periodic replacement is
                                                                                                                      recommended to ensure the level of waterproofing specified in IP66 (indoor
                                                                                                                      use). The time for periodic replacement depends on the operating environ-
                                                                                                                      ment. Be sure to confirm this point at your site. Consider one year a rough
                                                                                                                      standard. OMRON shall not be liable for the level of water resistance if the
                                                                                                                      customer does not perform periodic replacement.)

                                                                                                                      The Waterproof Packing does not need to be attached if a waterproof structure
                                                                                                                      is not required.

                                                                                                                      Current Transformers (Order Separately)

                                                                                                                      E54-CT1                                   21                               2.8

                                                                                                                                                                15         5.8 dia.

                                                                                                                                                                                                      7.5

                                                                                                                                                     25 3                                10.5
                                                                                                                                                            10  40

                                                                                                                                                                                  Two, 3.5 dia.

                                                                                                                                                                30

E54-CT3                                                    2.36 dia.                             E54-CT3 Accessory                          Connection Example
                        30                                                                        Armature
                                                                                                                                                                Armature
                                         12 dia.
                                                                                                                                                     Plug
                                                                                            9
                                                                                                     Approx. 3 dia.                                                        Lead

         40 40                                                        Two, M3 (depth: 4)                                              18
            15
                                                                                                 Plug

                                                                                                 Approx. 6 dia.

                        30                                                                                                     (22)

                                                                                                                                                                                                           25
E5@Z

Operation

Setting Levels Diagram

This diagram shows all of the setting levels. To move to the advanced function setting level, you must enter passwords. Some parameters are not
displayed depending on the protect level setting and the conditions of use.
Control stops when you move from the operation level to the initial setting level.

                                                  Power ON

                    Started in manual mode.                   Started in automatic mode.

                    Press the O Key

                    for at least 1 s.                                                                                              Press the O +
                                                                                                                                   M keys; display
                                                 Operation Level            Adjustment Level

                    C a-m                                         Press the                           Press the O           will flash.
                                                                  O Key less than 1 s.                + M Keys for
                                                                                                      at least 1 s.  C 25

                          Press the O Key for     Press the              C          Press the O Key for at                         100
                          at least 1 s; display   O Key                     25 least 1 s; display will flash.
                    (See  will flash.                                               Press the O Key for at                         Press the O +
                    note  Press the Ol Key for                (See          100     least 3 s. Control stops.                      M Keys for at
    Manual          2.)   at least 3 s while a-m  for at      note 1.)
    mode                                          least 1 s.

                                                                                                                                   least 3 s. (See

            Manual Control                        Initial Setting Level                  Communi-                             note.)
            Level                                                                        cations               Protect level
                                                                            Press the Setting

                                                                            O Key for less than 1 s.

                                       Press the O Key                      Input password.                       Note: The time taken to move
                                       for at least 1 s.                    Set value -169                                to the protect level can
                                                                                                                          be adjusted by
                                                              Advanced Function                                           changing the "Move to
                                                              Setting Level                                               protect level time"

                                                                                                               Control in progress

                                                                                                               Control stopped

                                                                                                                                       Not displayed for some models

                                                                                                                                       Level change
Note: 1. Moves to operation level by software reset.

        2. From the manual control level, key operations can be used to move to the operation level only.

Error Displays (Troubleshooting)

When an error occurs, the No.1 display shows the error code. Take necessary measure according to the error code, referring the table below.

                                                                                                                                        Output status at error

    No. 1 display   Meaning                                                 Action                                                 Control  Alarm outputs
                                                                                                                                   outputs

                    Input error        Check the wiring of inputs for miswiring, disconnections, and short-circuits and check the  OFF      Operates as
                    (See note 2.)      input type.                                                                                          above the upper
                                                                                                                                            limit.
    s.err (S. Err)  A/D converter      Check for an input error and then cycle the power supply. If the same error is still
                    error              displayed, repairs will be necessary.                                                                OFF
                    (See note 2.)      If the Temperature Controller is normal after cycling the power supply, the error may have  OFF
                                       been caused by noise. Check for noise being generated nearby.

    e111 (E111)     Memory error       Cycle the power supply. If the same error is still displayed, repairs will be necessary. OFF         OFF
    h.err (H. Err)                                                                                                                          OFF
                    HB error           If the Temperature Controller is normal after cycling the power supply, the error may have  OFF
                    (See note 2.)
                                       been caused by noise. Check for noise being generated nearby.

Note: 1. If the input value exceeds the display limit (-1999 to 9999), though it is within the control range,        will be displayed under -1999 and

                    above 9999. Under these conditions, control output and alarm output will operate normally.

    For details on the control range, refer to the E5CZ/E5CZ-U/E5AZ/E5EZ Digital Temperature Controllers User's Manual (Cat. No. H207).

    2. These errors are displayed only when the PV/SP is displayed. Errors are not displayed in other display modes.

26
E5@Z

     27
E5@Z

Parameters                                                                                                             Power ON                     Press the O Key for at
                                                                                                                                                    least 3 s. Displays other than
Some parameters are not displayed depending on the                                                                                                  that for switching between
model of the Controller and parameter settings. For details,                                                                                        automatic and manual.
refer to the E5CZ/E5CZ-U/E5AZ/E5EZ Digital
Temperature Controllers User's Manual (Cat. No. H207).

                                                                                         Starting in manual mode.

                                                                                            Manual control level                                 Starting in automatic
                                                                                                                                                 mode.
                                                                                         C              25 PID control         Press the
                                                                                                                               O Key for
                                                                                                            only               at least 1 s

                                                                                         PV/MV

       Adjustment Level                          Press the O Key less than 1 s.                                                Operation Level
                                                 Press the O Key less than 1 s.

                                                 C  p Proportional band                                 C 25 Process value                       C al-1 Alarm value 1          Set either of these parameters. Set either of these parameters. Set either of these parameters.

                                                                                                                    Added when Additional           0
                                                                                                              M PV display is ON.
                                                    8.0                                                                                             M

                                                    M                                                   C 25 Process value/                      C  al1h       Alarm  value
                                                                                                                                                               upper  limit 1
    P at AT execute/cancel                       P  i Integral time                                              0 set point                                0

       off                                          233                 PID settings                          M       Auto/manual switch            M
                                                                                                                      PID control only.
       M                                            M                                                   a-m P                                    C  al1l       Alarm value
                                                                                                                                                               lower limit 1
       cmwt Communications writing               P  d Derivative time                    Press the                    Added when auto/manual                0
                                                                                         OKey for                     select addition is ON.
                                                                                         at least 3 s.        M                                     M
       off                                          40
                                                                                                        P m-sp Multi-SP                          C al-2 Alarm value 2
       M                                            M
                                                                                                                 0 set point setting                        0
    P  ct1        Heater current  1  value       P c-sc Cooling coefficient
                  monitor
           0.0                                          1.00                                                  M                                     M
                                                         M
                                                                     Heating/cool-                      C sp-m Set point during SP               C  al2h       Alarm  value
                                                 C c-db Dead band    ing                                                                                       upper  limit 2
       M                                                                                                         0 ramp                                     0

    P  lcr1       Leakage  current   1
                  monitor
             0.0                                    0.0                                                       M                                     M

                                                                                                        P  ct1        Heater current  1   value  C  al2l       Alarm value
                                                                                                                      monitor                                  lower limit 2
       M                                            M                                                         0.0                                           0

    P hb1 Heater burnout detection 1             P  of-r  Manual reset value
                                                          Clear the offset during
                                                                                   sta-                       M                                     M

       0.0                                          50.0 bilization of P or PD control.                 P  lcr1       Leakage  current    1      C al-3 Alarm value 3
                                                                                                                      monitor
       M                                            M                                                            0.0                                0

    P hs1 HS alarm 1                             C hys Hysteresis (heating)                                   M                                     M

       50.0                                         1.0                 Hysteresis                      P r-s RUN/STOP                           C  al3h       Alarm  value
                                                                                                                                                               upper  limit 3
       M                                            M                   settings                              run                                           0

    C sp-0 SP 0                                  C chys Hysteresis (cooling)                                  M                                     M

       0                                            1.0                                                                                          C  al3l       Alarm value
                                                                                                                                                               lower limit 3
       M                                            M                                                                                                       0

    C sp-1 SP1                                   C sprt SP ramp set value                                                                           M

               0           SP used by                   off                                                                                      P  o MV monitor
                           multi-SP
            M                                       M                                                                                               0.0 (heating)

    C sp-2 SP 2                                  P ol-h MV upper limit                                                                              M

       0                                              105.0                                                                                      P  c-o        MV monitor
                                                                                                                                                               (cooling)
       M                                            M                                                                                                  0.0

    C sp-3 SP 3                                  P ol-l MV lower limit                                                                              M

       0                                                -5.0

       M                                            M                                                                                                                          Press the OKey
                                                                                                                                                                               less than 1 s
    C ins Temperature input shift                                                        Press the O and M Keys for at                        Press the O and M Keys
                                  1-point shift                                          least 3 s. Display flashes.                          for at least 1 s.
       0.0
                                                                                                        Protect Level
       M                                                                                                                                         Communications Setting Level

    C  insh       Upper-limit temperature        Set either of these parameters.
                  input shift value
       0.0                                                                               The time taken to move to the protect level can be      Displayed only for models with communications.
                                                                                         adjusted by changing the "Move to protect level         Changes are effective after cycling power or
       M                          2-point shift                                          time" setting.                                          after a software reset.

    C  insl       Lower-limit temperature
                  input shift value
             0.0                                                                                              Operation/adjustment protect          psel Protocol setting
                                                                                                              Restricts displaying and                         Switches between CompoWay/F
                                                                                            oapt P            modifying menus in operation,             cwf (SYSWAY) and Modbus.
       M                                                                                                      adjustment, and manual                   M
                                                                                                              control levels.
                                                                                                           0

                                                                                                        M     Initial setting/communications        u-no Communications Unit No.
                                                                                                                                                            1
                                                                                            icpt P            protect
                                                                                                              This protect level restricts
                                                                                                           1 movement to the initial setting,       M
                                                                                                              communications setting, and
                                                                                                        M     advanced function setting levels.     bps        Communications baud rate
                                                                                                                                                                              CompoWay/F
                                                                                            wtpt P                                                  9.6                 (SYSWAY) only
                                                                                                           Setting change protect
                                                                                                   off Protects changes to setups by                M
                                                                                                           operating the front panel keys.
                                                                                                   M                                                len        Communications
                                                                                                                                                         7     data length

                                                                                                                                                    M

                                                                                                                                                    sbit Communications stop bits
                                                                                                                                                            2

                                                                                                                                                    M

                                                                                                                                                    prty Communications parity
                                                                                                                                                      even

                                                                                                                                                       M

                                                                                                                                                    sdwt Send data wait time
                                                                                                                                                          20

                                                                                                                                                       M

28
                                                                                                                                        E5@Z

       Initial Setting Level                   Press the O Key for at least 1 s.
Press the O Key less than 1 s.                         Advanced Function Setting Level

P in-t Input type                              init P  Parameter initialization  pvad P    Additional PV display  amad Auto/manual select
           5                                                                                                                  addition
                                                                                                                       off
M                                              off                               off

P in-h Scaling upper limit                     M                                 M                                M

       100                                     ev-m P  Number of multi-SP uses   P o-dp MV display                hsu P   HS alarm use

M                                                      Two SPs: 1                off
                                               1 Four SPs: 2
P in-l Scaling lower limit                                                                                        on

           0                                   M                                 M                                M

M                                              ev-1 P  Event input               ret P     Automatic display      hsl P   HS alarm latch
                                                                                           return time
                                               none    assignment 1              off
dp P                                                                                                              off
        Decimal point
                                                                                 M
     0                                         M                                                                  M
                For input type of analog
M                                              ev-2 P  Event input               P a1lt Alarm 1 latch             hsh P   HS alarm hysteresis
                                                       assignment 2
d-u P   Temperature unit                       stop                              off                              0.1
        C, F
     c                 For input type of       M                                 M                                M
                       temperature
M                                              P mspu Multi-SP uses              P a2lt Alarm 2 latch             lba P   LBA detection time

C sl-h SP upper limit                          off                               off                              0

1300                   Limit the set point     M                                 M                                M

M                                              spru P  SP ramp time unit         P a3lt Alarm 3 latch             C lbal LBA level

C sl-l SP lower limit                          m                                 off                                      8.0

     -200                                      M                                 M                                M

M                                              rest P  Standby sequence          prlt P    Move to protect level  C lbab LBA band

P cntl PID ON/OFF                                      reset                            3  time                           3.0

     onof                                      a

                                               M                                 M                                M

M                                              al1n P  Alarm 1 open in alarm     sero P    Input error output     out1 P  Control output 1

s-hc P  Standard or heating/cooling            n-o                               off                              o assignment

stnd                   For input type of tem-  M                                 M                                M

M                      perature, standard              Alarm 1 hysteresis        cjc P     Cold junction compen-
                       control, or PID         alh1 C                                                             P alm1 Alarm output 1
P st ST                When assigning PID                                        on        sation method               alm1 assignment

on      (self-tuning) or control output to     0.2

M                              pulse output    M                                 M                                M

cp P                                           al2n P  Alarm 2 open in alarm     rlrv P    MB command logic       P alm2 Alarm output 2
                                                                                           switching                   alm2 assignment
        Control period (heating)               n-o                               off

20                                             M                                 M                                M

M               Set the pulse output cycle.

P c-cp Control period (cooling)                alh2 C  Alarm 2 hysteresis        P a1on Alarm 1 ON delay          alm3 P  Alarm output 3
                                                                                                                          assignment
         20                                    0.2                                          0                     alm3 (E5AZ/E5EZ only)

M                                              M                                 M                                M

oreV P  Direct/reverse operation               al3n P  Alarm 3 open in alarm     P a2on Alarm 2 ON delay          csel P  Character select

or-r                                           n-o                                      0                         on

M                                              M                                 M                                M

P alt1 Alarm 1 type                            alh3 C  Alarm 3 hysteresis        P a3on Alarm 3 ON delay

           2                                   0.2                                      0

M                                              M                                 M

P alt2 Alarm 2 type                            P hbu HB ON/OFF                   a1of P    Alarm 1 OFF delay

           2                                   on                                       0

M                                              M                                 M

P alt3 Alarm 3 type                            hbl P   Heater burnout latch      a2of P    Alarm 2 OFF delay

           2                                   off                                      0

M                                              M                                 M

P tr-t Transfer output type                    hbh P   Heater burnout            a3of P    Alarm 3 OFF delay

off                    Linear output           0.1     hysteresis                       0

M                                                                                M

tr-h P  Transfer output upper limit            M

100.0                                          C st-b ST stable range            istp P    Input shift type

M                                              15.0                              ins1

tr-l P  Transfer output lower limit            M                                 M

0.0                                            P alfa

M                                              0.65

P o1-t Linear current output                   M

4-20                                           inf P   Input digital filter
  M
                            Linear output      0.0

amov P  Move to advanced function              M
        setting level
        Displayed when initial setting/
     0  communications protection is           Move by setting password (-169).

M set to 0.

                                                                                                                                               29
E5@Z                                                           Precautions in Replacing Previous Controllers

Improved Functions                                              Previous E5@Z Controllers cannot be removed from the case for
                                                                  replacement with new models. Replace the case at the same time.
Changes

Model numbers have been changed to allow for universal input
specifications.

Before Change

  E5@Z-@@@ (models for thermocouples and platinum resistance
  thermometers)
  None (models for analog input)
  None (models for 24 VAC/VDC)

After Change

  E5@Z-@@@T (models for thermocouples and platinum resistance
  thermometers)
  E5@Z-@@@L (models for analog input)
  E5@Z-@@@@D (models for 24 VAC/VDC)

    The following items have not changed in comparison to the previous E5@Z models: Panel cutout, Internal
    panel dimensions for panel mounting, wiring screw sizes, wiring terminal arrangement, and parameter setting
    methods.

Improved Functions

The previous and new models can be easily differentiated by looking at the front panel. The OMRON logo is in a different position.

                        Item  Previous models (OMRON logo: lower left)  Improved models (OMRON logo: upper left)
    Front panel

    E5CZ/E5CZ-U               ALM1
                              ALM2
                              HB
                              OUT1 STOP
                              OUT2 CMW

    E5AZ

    E5EZ

30
                                                                         E5@Z

Specifications (Main Changes)

Ratings

         Item                                      Previous models                                 Improved models
            E5CZ
                         7 VA (100 to 240 VAC, 50/60 Hz)                 7.5 VA (100 to 240 VAC, 50/60 Hz)
                         4 VA/3 W (24 VAC, 50/60 Hz or 24 VDC)           5.5 VA/3.5 W (24 VAC, 50/60 Hz or 24 VDC)

Power     E5CZ-U         (No models with plug-in type)                   6 VA (100 to 240 VAC, 50/60 Hz)
                                                                         4.5 VA/2.5 W (24 VAC, 50/60 Hz or 24 VDC)
consump-                 9 VA (100 to 240 VAC, 50/60 Hz)
                         5 VA/4 W (24 VAC, 50/60 Hz or 24 VDC)           8.5 VA
tion      E5AZ           9 VA (100 to 240 VAC, 50/60 Hz)                 6 VA/4 W
                         5 VA/4 W (24 VAC, 50/60 Hz or 24 VDC)
          E5EZ                                                           8.5 VA
                                                                         6 VA/4 W
Sensor input             (No models with analog inputs)
                                                                         E5@Z-@@@@L@ (Models with analog inputs added.)
                         E5CZ-R@@@                                         Current input: 4 to 20 mA or 0 to 20 mA
                           SPST-NO, 250 VAC, 3 A (resistive load)          Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
                           Electrical life: 100,000 operations
                                                                         E5CZ-R@@@@
          Relay          (No models with plug-in type)                     SPST-NO, 250 VAC, 3 A (resistive load)
                                                                           Electrical life: 100,000 operations
                         E5AZ-R@@@
                           SPST-NO, 250 VAC, 5 A (resistive load)        E5CZ-R@@@U
                           Electrical life: 100,000 operations             SPDT, 250 VAC, 3 A (resistive load)
                                                                           Electrical life: 100,000 operations
                         E5EZ-R@@@
                           SPST-NO, 250 VAC, 5 A (resistive load)        E5AZ-R@@@@@
                           Electrical life: 100,000 operations             SPST-NO, 250 VAC, 5 A (resistive load)
                                                                           Electrical life: 100,000 operations
                         E5CZ-Q@@@
                           12 VDC 15% (PNP)                             E5EZ-R@@@@@
                           Max. load current: 21 mA                        SPST-NO, 250 VAC, 5 A (resistive load)
                           With short-circuit protection                   Electrical life: 100,000 operations

Control                  (No models with plug-in type)                   E5CZ-Q@@@@
output 1 Voltage                                                           12 VDC 15% (PNP)
                         E5AZ-Q@@@                                         Max. load current: 21 mA
                Current    12 VDC +15%/-20% (PNP)                          With short-circuit protection
                           Max. load current: 40 mA
                           With short-circuit protection                 E5CZ-Q@@@U
                                                                           12 VDC 15% (PNP)
                         E5EZ-Q@@@                                         Max. load current: 21 mA
                           12 VDC +15%/-20% (PNP)                          With short-circuit protection
                           Max. load current: 40 mA
                           With short-circuit protection                 E5AZ-Q@@@@@
                                                                           12 VDC +15%/-20% (PNP)
                         E5CZ-C@@@                                         Max. load current: 40 mA
                           4 to 20 mA DC                                   With short-circuit protection
                           Load: 600  max.
                           Resolution: Approx. 2,600                     E5EZ-Q@@@@@
                                                                           12 VDC +15%/-20% (PNP)
                         E5AZ-C@@@                                         Max. load current: 40 mA
                           4 to 20 mA DC                                   With short-circuit protection
                           Load: 600  max.
                           Resolution: Approx. 2,600                     E5CZ-C@@@@
                                                                           4 to 20 mA DC or 0 to 20 mA DC
                         E5EZ-C@@@                                         Load: 600  max.
                           4 to 20 mA DC                                   Resolution: Approx. 2,700
                           Load: 600  max.
                           Resolution: Approx. 2,600                     E5AZ-C@@@@
                                                                           4 to 20 mA DC or 0 to 20 mA DC
Display   E5CZ/CZ-U 7-segment digital display and single-LED indicators    Load: 600  max.
method    E5AZ/EZ 7-segment digital display and single-LED indicators      Resolution: Approx. 2,700

Transfer output          (No models with transfer outputs)               E5EZ-C@@@@
                                                                           4 to 20 mA DC or 0 to 20 mA DC
                                                                           Load: 600  max.
                                                                           Resolution: Approx. 2,700

                                                                         11-segment digital display and single-LED indicator
                                                                         (Improved visibility)
                                                                         (A 7-segment digital display also possible.)

                                                                         11-segment digital display and single-LED indicator
                                                                         (Improved visibility)
                                                                         (A 7-segment digital display also possible.)

                                                                         E5@Z-C@@@@
                                                                           Allocated to current output
                                                                           4 to 20 mA DC or 0 to 20 mA DC
                                                                           Load: 600  max.
                                                                           Resolution: Approx. 2,700 (4 to 20 mA DC)

                                                                                                                              31
E5@Z

Other Functions

           Item                            Previous models                                                           Improved models
                                                                                         Display character switch (7-segment/11-segment)
    Display               ---                                                            Temperature input shift (2-point shift also possible for
                                                                                         temperature input)
    Input                 Temperature input shift (1-point shift for temperature input,  Manual outputs
                          2-point shift for no-contact sensor input)                     Loop break alarm
                                                                                         Control period: 0.5 or 1 to 99 s
    Output                ---                                                            Alarm delays

                          ---

    Control               Control period: 1 to 99 s

    Alarm                 ---

Characteristics

                    Item                             Previous models                             Improved models
    Sampling period
                                   500 ms                                                250 ms

Communications Specifications

                 Item                                Previous models                                             Improved models
                                                                                         CompoWay/F (SYSWAY), Modbus
    Communications protocols CompoWay/F (SYSWAY)                                         1200, 2400, 4800, 9600, 19200, 38400 bps

    Baud rate                      1200, 2400, 4800, 9600, 19200 bps

Heater Burnout/Heater Short Alarm Characteristics

           Item                                      Previous models                                             Improved models
                                                                                         E5CZ-@2M@@ with E53-CZH@
                          E5CZ     E5CZ-@2M@ with E53-CNH@N                              Single-phase 50 A AC
                                   Single-phase 50 A AC
                                                                                         E5@Z-@3HM@@
    Maximum heater        E5AZ/EZ  E5@Z-A3 with E53-AZM and E53-AZH                      Single-phase 50 A AC
    current                        E5@Z-R3 with E53-AZM and E53-AZH
                                   E5@Z-Q3 with E53-AZM and E53-AZH                      Heater short alarm
                                   Single-phase 50 A AC

    Heater short alarm             ---

32
Precautions                                                                                               E5@Z

                            !CAUTION                          Do not allow pieces of metal or wire cuttings to get inside
                                                              connectors. Failure to do so may occasionally result in
Do not touch the terminals while power is being supplied.     minor electric shock, fire, or damage to equipment.
Doing so may occasionally result in minor injury due to
electric shock.                                               Do not allow dust and dirt to collect between the pins in
                                                              the connector on the Conversion Cable. Failure to do so
Do not allow pieces of metal, wire clippings, or fine         may occasionally result in fire.
metallic shavings or filings from installation to enter the
product. Doing so may occasionally result in electric         When inserting the body of the Temperature Controller
shock, fire, or malfunction.                                  into the case, confirm that the hooks on the top and
                                                              bottom are securely engaged with the case. If the body of
Do not use the product where subject to flammable or          the Temperature Controller is not inserted properly, faulty
explosive gas. Otherwise, minor injury from explosion         contact in the terminal section or reduced water
may occasionally occur.                                       resistance may occasionally result in fire or malfunction.

Do not leave the conversion cable connected to the            Note: 1. An SELV circuit is one separated from the power supply
product. Malfunction may occur due to noise in the cable.                 with double insulation or reinforced insulation, that does not
                                                                          exceed 30 V r.m.s. and 42.4 V peak or 60 VDC.
Do not use the Temperature Controller or Conversion
Cable if it is damaged. Doing so may occasionally result              2. A class 2 power supply is one tested and certified by UL as
in minor electric shock or fire.                                          have the current and voltage of the secondary output
                                                                          restricted to specific levels.
Never disassemble, modify, or repair the product or touch
any of the internal parts. Minor electric shock, fire, or             3. The tightening torque for E5CZ-U is 0.5 Nm.
malfunction may occasionally occur.

CAUTION - Risk of Fire and Electric Shock
a) This product is UL recognized as Open Type Process

    Control Equipment. It must be mounted in an
    enclosure that does not allow fire to escape externally.
b) More than one disconnect switch may be required to
    de-energize the equipment before servicing the
    product.
c) Signal inputs are SELV, limited energy. (See note 1.)
d) Caution: To reduce the risk of fire or electric shock, do
    not interconnect the outputs of different Class 2
    circuits. (See note 2.)

If the output relays are used past their life expectancy,
contact fusing or burning may occasionally occur.
Always consider the application conditions and use the
output relays within their rated load and electrical life
expectancy. The life expectancy of output relays varies
considerably with the output load and switching
conditions.

Tighten the terminal screws to between 0.74 and
0.90 Nm. Loose screws may occasionally result in fire.
(See note 3.)

Set the parameters of the product so that they are
suitable for the system being controlled. If they are not
suitable, unexpected operation may occasionally result in
property damage or accidents.

A malfunction in the product may occasionally make
control operations impossible or prevent alarm outputs,
resulting in property damage. To maintain safety in the
event of malfunction of the product, take appropriate
safety measures, such as installing a monitoring device
on a separate line.

                                                              33
E5@Z

    Precautions for Safe Use                                                     18.Always touch a grounded piece of metal before touching the
                                                                                     Temperature Controller to discharge static electricity from your
      Be sure to observe the following precautions to prevent malfunction            body.

      or adverse affects on the performance or functionality of the product.     19.Control output that is voltage output is not isolated from the
                                                                                     internal circuits. When using a grounded thermocouple, do not
      Not doing so may occasionally result in faulty operation.                      connect any of the control output terminals to ground. (Doing so
                                                                                     may result in an unwanted circuit path, causing error in the
      1. This product is specifically designed for indoor use only.                  measured temperature.
          Do not use this product outdoors or in any of the following places:
          Places directly subject to heat radiated from heating equipment.     20.When replacing the body of the Temperature Controller, check the
                                                                                     condition of the terminals. If corroded terminals are used, contact
          Places subject to splashing liquid or oil atmosphere.                    failure in the terminals may cause the temperature inside the
                                                                                     Temperature Controller to increase, possibly resulting in fire. If the
          Places subject to direct sunlight.                                       terminals are corroded, replace the case as well.

          Places subject to dust or corrosive gas (in particular, sulfide gas  21.Use suitable tools when taking the Temperature Controller apart
                                                                                     for disposal. Sharp parts inside the Temperature Controller may
            and ammonia gas).                                                        cause injury.

          Places subject to intense temperature change.                        22.Check the orientation of the connectors on the Conversion Cable
                                                                                     before connecting the Conversion Cable. Do not force a connector
          Places subject to icing and condensation.                                if it does not connect smoothly. Using excessive force may
                                                                                     damage the connector.
          Places subject to vibration and large shocks.
                                                                                 23.Do not place heavy object on the Conversion Cable, bend the
      2. Use and store the product within the rated ambient temperature              cable past its natural bending radius, or pull on the cable with
          and humidity.                                                              undue force.
          Gang-mounting two or more Temperature Controllers, or
          mounting Temperature Controllers above each other may cause            24.Do not connect or disconnect the Conversion Cable while
          heat to build up inside the Temperature Controllers, which will            communications are in progress. Product faults or malfunction
          shorten their service life. In such a case, use forced cooling by          may occur.
          fans or other means of air ventilation to cool down the
          Temperature Controllers.                                               25.Make sure that the Conversion Cable's metal components are not
                                                                                     touching the external power terminals.
      3. To allow heat to escape, do not block the area around the product.
          Do not block the ventilation holes on the product.                     26.Do not touch the connectors on the Conversion Cable with wet
                                                                                     hands. Electrical shock may result.
      4. Be sure to wire properly with correct polarity of terminals.
      5. Use the specified size (M3.5, width 7.2 mm or less) crimped             Precautions for Correct Use

          terminals for wiring. To connect bare wires to the terminal block,     Service Life
          use stranded or solid copper wires with a gage of AWG24 to
          AWG14 (equal to a cross-sectional area of 0.205 to 2.081 mm2).         1. Use the product within the following temperature and humidity
          (The stripping length is 5 to 6 mm.) Up to two wires of the same           ranges:
          size and type or two crimp terminals can be inserted into a single         Temperature: -10 to 55C (with no icing or condensation)
          terminal.                                                                  Humidity: 25% to 85%
      6. Do not wire the terminals that are not used.                                If the product is installed inside a control board, the ambient
      7. To avoid inductive noise, keep the wiring for the product's terminal        temperature must be kept to under 55C, including the
          block away from power cables carry high voltages or large                  temperature around the product.
          currents. Also, do not wire power lines together with or parallel to
          product wiring. Using shielded cables and using separate conduits      2. The service life of electronic devices like Temperature Controllers
          or ducts is recommended.                                                   is determined not only by the numberof times the relay is switched
          Attach a surge suppressor or noise filter to peripheral devices that       but also by the service life of internal electronic components.
          generate noise (in particular, motors, transformers, solenoids,            Component service life is affected by the ambient temperatrue: the
          magnetic coils, or other equipment that have an inductance                 higher the temperature, the shorter the service life and, the lower
          component).                                                                the temperature, the longer the service life. Therefore, the service
          When a noise filter is used at the power supply, first check the           life can be extended by lowering the temperature of the
          voltage or current, and attach the noise filter as close as possible       Temperature Controller.
          to the product.
          Allow as much space as possible between the product and                3. When two or more Temperature Controllers are mounted
          devices that generate powerful high frequencies (high-frequency            horizontally close to each other or vertically next to one another,
          welders, high-frequency sewing machines, etc.) or surge.                   the internal temperature will increase due to heat radiated by the
      8. Use this product within the rated load and power supply.                    Temperature Controllers and the service life will decrease. In such
      9. Make sure that the rated voltage is attained within 2 seconds of            a case, use forced cooling by fansor other means of air ventilation
          turning ON the power by using a switch or relay contact. If the            to cool down the Temperature Controllers. When providing forced
          voltage is applied gradually, the power may not be reset or output         cooling, however, be careful not to cool down the terminals
          malfunctions may occur.                                                    sections alone to avoid measurement errors.
      10.Make sure that the Temperature Controller has 30 minutes or
          more to warm up after turning ON the power before starting actual      Measurement Accuracy
          control operations to ensure the correct temperature display.
      11.When executing self-tuning, turn ON power to the load (e.g.,            1. When extending or connecting the thermocouple lead wire, be
          heater) at the same time as or before supplying power to the               sure to use compensating wires that match the thermocouple
          product. If power is turned ON to the product before turning ON
          power to the load, self-tuning will not be performed properly and          types.
          optimum control will not be achieved.
      12.A switch or circuit breaker must be provided close to the product.      2. When extending or connecting the lead wire of the platinum
          The switch or circuit breaker must be within easy reach of the             resistance thermometer, be sure to use wires that have low
          operator, and must be marked as a disconnecting means for this
          unit.                                                                      resistance and keep the resistance of the three lead wires the
      13.Always turn OFF the power supply before pulling out the interior of
          the product, and never touch nor apply shock to the terminals or           same.
          electronic components. When inserting the interior of the product,
          do not allow the electronic components to touch the case.              3. Mount the product so that it is horizontally level.
      14.Do not use paint thinner or similar chemical to clean with. Use         4. If the measurement accuracy is low, check to see if input shift has
          standard grade alcohol.
      15.Design the system (e.g., control panel) considering the 2 seconds           been set correctly.
          of delay that the product's output to be set after power ON.
      16.The output may turn OFF when shifting to certain levels. Take this      Waterproofing
          into consideration when performing control.
      17.The number of EEPROM write operations is limited. Therefore,            The degree of protection is as shown below. Sections without any
          use RAM write mode when frequently overwriting data during             specification on their degree of protection or those with IP@0 are not
          communications or other operations.                                    waterproof.

34                                                                               E5CZ    Front panel: IP66 (indoor use)
                                                                                 E5AZ    Rear case: IP20, Terminal section: IP00
                                                                                 E5EZ

                                                                                 E5CZ-U  Front panel: Equivalent to IP50, rear case: IP20,
                                                                                         Terminals: IP00
                                                                                                                                                       E5@Z

Precautions for Operation                                                                     E5EZ/E5AZ

1. It takes approximately 2 seconds for the outputs to turn ON from                                                            Mounting
    after the power supply is turned ON. Due consideration must be                                                             Bracket
    given to this time when incorporating Temperature Controllers in a                                                         (Accessory)
    sequence circuit.
                                                                                                                                                Panel
2. When using self-tuning, turn ON power for the load (e.g., heater)
    at the same time as or before supplying power to the Temperature                          Terminal Cover                   E5EZ
    Controller. If power is turned ON for the Temperature Controller                          (E53-COV11)
    before turning ON power for the load, self-tuning will not be                             (order separately)
    performed properly and optimum control will not be achieved.
                                                                                                           Waterproof packing
3. When starting operation after the Temperature Controller has                                            (Accessory)
    warmed up, turn OFF the power and then turn it ON again at the
    same time as turning ONpower for the load. (Instead of turning the                                                         Mounting     Panel
    Temperature Controller OFF and ON again, switching from STOP                                                               Bracket
    mode to RUN mode can also be used.)                                                                                        (Accessory)

4. Avoid using the Controller in places near a radio, television set, or                      Terminal Cover
    wireless installing. These devices can cause radio disturbances                           (E53-COV11)
    which adversely affect the performance of the Controller.
                                                                                                         Waterproof packing          E5AZ
USB-Serial Conversion Cable                                                                              (Accessory)

1. The disk that is included with theConversion Cable is designed for                         1. For waterproof mounting, waterproof packing must be installed on
    a computer CD-ROM driver. Never attempt to play the disk in a                                 the Controller. Waterproofing is not possible when group mounting
    general-purpose audio player.                                                                 Controllers. Waterproof packing is not necessary when there is no
                                                                                                  need for the waterproof function.
2. Do not connect or disconnect the Conversion Cable connector
    repeatedly over a short period of time. The computer may                                  2. Insert the E5AZ/E5EZ into the square mounting hole in the panel
    malfunction.                                                                                  (thickness: 1 to 8 mm). Attach the Mounting Brackets provided
                                                                                                  with the product to the mounting grooves on the top and bottom
3. After connecting the Conversion Cable to the computer, check the                               surfaces of the rear case.
    COM port number before starting communications. The computer
    requires time to recognize the cable connection. This delay does                          3. Use a ratchet to alternately tighten the screws on the top and
    not indicate failure.                                                                         bottom Mounting Brackets little by little to maintain balance, until
                                                                                                  the ratchet turns freely.
4. Do not connect the Conversion Cable through a USB hub. Doing
    so may damage the Conversion Cable.                                                       Mounting the Terminal Cover

5. Do not use an extension cable to extend the Conversion Cable                               For the E5CZ, make sure the "UP" characters on the Cover are in the
    length when connecting to the computer. Doing so may damage                               correct position and insert the Cover into the holes at the top and
    the Conversion Cable.                                                                     bottom.
                                                                                              For the E5EZ or E5AZ, fit the E53-COV11 Terminal Cover over the
6. For models with communications, the same port is used by the                               upper hook. Mount it in the direction shown in the above diagram. If
    Setting Tool port and for communications via the communications                           the Terminal Cover is mounted in the opposite direction, proper
    terminals. Do not use communications via the communications                               mounting of the fixtures may not be possible.
    terminals when using the Setting Tool port.

Mounting

Mounting to the Panel
E5CZ

                                                                  Order the P2CF-11 or
                                                                  P3GA-11 Socket separately.

           Terminal Cover

           E53-COV17
           (order separately)

                             Adapter
                             (order separately)

                               E5CZ-U

Waterproof packing             For Front-mounting Socket
(Accessory)                    (Panel mounting is also possible.)

                  Panel  E5CZ

1. For waterproof mounting, waterproof packing must be installed on
    the Controller. Waterproofing is not possible when group mounting

    Controllers. Waterproof packing is not necessary when there is no

    need for the waterproof function.

    There is no waterproof function for the E5CZ-U.

2. Insert the E5CZ/E5CZ-U into the mounting hole in the panel.
3. Push the adapter from the terminals up to the panel, and

    temporarily fasten the E5CZ/E5CZ-U.

4. Tighten the two fastening screws on the adapter. Alternately
    tighten the two screws little by little to maintain a balance. Tighten

    the screws to a torque of 0.29 to 0.39 Nm.

                                                                                                                                                       35
E5@Z                        0.4
                                       2.0
Removing the Temperature Controller from the
Case                                            20 min.

E5CZ/EZ/AZ

The Temperature Controller can be removed from the case to perform
maintenance without removing the terminal leads. This is possible for
only the E5CZ, E5AZ, and E5EZ, and not for the E5CZ-U. Check the
specifications of the case and Temperature Controller before
removing the Temperature Controller from the case.

                                                                  Flat-blade screwdriver
                                                                  (Unit: mm)

                                 (1)
                                 (2)
                                 (3)
                                  (1)

          E5CZ/CZ-U

                                                                 (1)
          (1)

                                                                 (2)
          (2)

          (3)                                                            (3)

          (1)                                                            (1)

    E5EZ       E5AZ

1. Insert a flat-blade screwdriver into the two tool insertion holes (one
    on the top and one on the bottom) to release the hooks.

2. Insert the flat-blade screwdriver in the gap between the front panel
    and rear case, and pull out the front panel slightly. Hold the top and
    bottom of the front panel and carefully pull it out toward you,
    without applying unnecessary force.

3. When inserting the E5CZ/EZ/AZ, check to make sure that the
    sealing rubber is in place and push the E5CZ/EZ/AZ toward the
    rear case until it snaps into position. While pushing the E5CZ/EZ/
    AZ into place, push down on the hooks on the top and bottom
    surfaces of the rear case so that the hooks are securely locked in
    place. Be sure that electronic components do not come into
    contact with the case.

Precautions when Wiring

Separate input leads and power lines in order to prevent external
   noise.

Use wires with a gage of AWG24 (cross-sectional area:
   0.205 mm2) to AWG14 (cross-sectional area: 2.081 mm2) twisted-
   pair cable (stripping length: 5 to 6 mm).

Use crimp terminals when wiring the terminals.
Tighten the terminal screws to a torque of 0.74 to 0.90 Nm.
Use the following types of crimp terminals for M3.5 screws.

               7.2 mm max.

                                                            7.2 mm max.

    Do not remove the terminal block. Doing so may result in
      malfunction or failure.

36
Digital Position-Proportional Controllers

E5EZ-PRR

A position proportional control model for the E5EZ-
PRR series

Depth of only 78 mm.
Various temperature inputs (thermocouple, platinum resistance thermometer,

  infrared temperature sensor, voltage inputs) and analog inputs (current, voltage)
Makes use of high-visibility LCD, with three lines of 4-digit display, for simplicity

  and clarity
3 lines of display to observe PV/ SV/ MV (valve open percentage), clearly

  displaying the state of control (operations)
Event input enables multi-SP selection and run/ stop function
Alarm delay function
Communications function
Able to choose closed/floating control. In floating control,

  position proportional control can be performed without a potentiometer
Equipped with a manual output function (equipped with an automatic/manual key)
CE marking and UL/CSA certification

Note: Refer to Precautions on page 59.

Model Number Structure

Model Number Legend
E5EZ-PRR@@@

             123456

1. Control method           4. Number of alarms               5. Option                  6. Input Type
                               Blank: Not available              Blank: Not available       T: Temperature
   P: Valve control                                              01: RS-232C                L: Analog input (current, voltage)
2. Control output 1            2: Two alarms                     03: RS-485
                                                                 B: 2 event inputs
   R: Relay (OPEN)
3. Control output 2

   R: Relay (CLOSE)

Ordering Information

        Size  Power supply  Input type      Control          Number of    Communica-     Event input  Model
                  voltage                   method             alarms           tions
1/8DIN
48 96 78                                               None              function    None         E5EZ-PRRT
(W H D)                                                                              2 points     E5EZ-PRR2T
                            Temperature                                 None             None         E5EZ-PRR2BT
                                                                                                      E5EZ-PRR201T
                            Input Type                     2            RS-232C          None         E5EZ-PRR203T
                                                                        RS-485           2 points     E5EZ-PRRL
              100 to                        Valve Control  None                          None         E5EZ-PRR2L
              240 VAC                                      2            None                          E5EZ-PRR2BL
                                                                                                      E5EZ-PRR201L
                            Analog                                      RS-232C                       E5EZ-PRR203L
                            (Current,                                   RS-485
                            Voltage) Input
                            Type

Accessories (Order Separately)                                   Terminal Cover

Unit Label                                                        Connectable models
                                                                  Model
Model                  Y92S-L1                                                           Terminal block models
                                                                                         E53-COV18

                                                                                                                    37
E5EZ-PRR

Input Range

Thermocouples / Platinum Resistance Thermometer

Input type                        Platinum resistance                                            Thermocouple                                                                     ES1B Infrared        Analog input
                                       thermometer                                                                                                                             temperature sensor

                                                                                                                                                                               10 60 115 140
    Name                             Pt100           JPt100               K            J      T            EL                   U             N R S B to to to to                                      0 to 50 mV
                                                                                                                                                                               70C 120C 165C 260C

                            1800                                                                                                                                         1800                          Usable in the
                            1700                                                                                                                      1700 1700                                        following ranges
                            1600

                            1500                                                                                                                                                                       by scaling:

    Temperature range (C)  1400                                    1300                                                                   1300                                                        -1999 to 9999 or
                            1300
                            1200                                                                                                                                                                       -199.9 to 999.9

                            1100

                            1000

                            900 850                                              850                                       850
                            800

                            700                                                                                       600
                                                                                       400.0 400 400.0
                            600      500.0           500.0                500.0
                            500
                                                                                                                                400 400.0
                            400

                            300                                                                                                                                                       165  260

                            200               100.0          100.0                                                                                                             70  120
                                                                                                                                                                                            115 140
                            100                                                                                                                             100

                            0                 0.0            0.0          -20.0        -20.0               0                                          0  0                     10 60
                            -100
                                                                                 -100                                      -100
                            -200 -200 -199.9                                                  -200 -199.9                           -200 -199.9 -200
                                                     -199.9         -200

Setting number 0 1 2 3 4 5 6 7 8 9 22 10 11 12 23 13 14 15 16 17 18 19 20                                                                                                                              21

The applicable standards for each of the above input ranges are as follows:

K, J, T, E, N, R, S, B: JIS C1602-1995, IEC 584-1

L:                                            Fe-CuNi, DIN 43710-1985

U:                                            Cu-CuNi, DIN 43710-1985

JPt100:                                       JIS C 1604-1989, JIS C 1606-1989

Pt100:                                        JIS C 1604-1997 IEC 751

Models with Analog Inputs                                                              Current [mA]                             Voltage [V]

Parameters                                                                      4 to 20 0 to 20 1 to 5 0 to 5 0 to 10

Set value                                                                             0         1                         2               3             4
Minimum Setting Unit (Set Value, Alarm)
                                                                                 (Scaling, according to the location of the decimal point)
     indicates factory settings.

Optional Functions

                                Type                                                        Performance
                            RS-232C                  Baud Rate: 1200/2400/4800/9600/19200bps
                            RS-485                   ON: Maximum of 1 K OFF: Minimum of 100 K
                            Event Input

38
                                                                                                                 E5EZ-PRR

Specifications

Ratings

Power supply voltage           100 to 240 VAC, 50/60 Hz
Operating voltage range
Power consumption              85% to 110% of rated supply voltage

Sensor input                   10 VA (10 W)

Control output  Relay output   Temperature input type
                (OUT1,OUT2)    Thermocouple: K, J, T, E, L, U, N, R, S, B
                               Platinum resistance thermometer: Pt100, JPt100
Potentiometer input            Infrared temperature sensor: 10 to 70C, 60 to 120C, 115 to 165C, 140 to 260C
                               Voltage input: 0 to 50 mV
Alarm output
                               Analog (current, voltage) input type
Event input     Contact input    Current input: 4 to 20 mA, 0 to 20 mA
                                 Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V
                Non-contact
                input          SPST-NO, 250 VAC 1A (resistive load)
                               Electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
Control method                 100  to 2.5 K
Setting method
                               SPST-NO, 250 VAC 2 A (resistive load)
Indication method              Electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA.
                               ON: 1 k max., OFF: 100 k min.
Other functions
Ambient operating temperature  ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Ambient operating humidity
Storage temperature            Outflow current: Approx. 7 mA per point

                               2-PID control

                               Digital setting using front panel keys

                               7-segment digital display and single-lighting indicators
                               Character height: PV: 9 mm; SV: 7 mm; MV: 6.8 mm

                               According to controller model
                               -10 to 55C (with no icing or condensation)

                               25% to 85%
                               -25 to 65C (with no icing or condensation)

Communications Specifications

Transmission line connection   RS-485: Multidrop
                               RS-232C:Point-to-point
Communications method (See
note 1.)                       RS-485 (two-wire, half duplex)/RS-232C
Synchronization method
Baud rate                      Start-stop synchronization
Communications code            1,200/2,400/4,800/9,600/19,200 bps
Data length (See note 2.)      ASCII
Stop bits (See note 2.)        7 or 8 bits
                               1 or 2 bits
Error detection                Vertical parity (none, even, odd)
                               Block check character (BCC)
Flow control                   Not available
Interface                      RS-485/RS-232C
Retry function                 Not available

                                                                                                                 39
E5EZ-PRR                   Thermocouple:
Specifications             (0.5% of indicated value or 1C, whichever is greater) 1 digit max. (See note 1.)
                           Platinum resistance thermometer:
Characteristics            (0.5% of indicated value or 1C, whichever is greater) 1 digit max.
                           Analog Input: 0.5% FS 1 digit max.
Indication accuracy       Potentiometer Input: 5% FS 1 digit max.

Influence of temperature  R, S, and B thermocouple inputs:
(See note 2.)             (1% of PV or 10C, whichever is greater) 1 digit max.
Influence of voltage      Other thermocouple inputs:
(See note 2.)             (1% of PV or 4C, whichever is greater) 1 digit max.
                           *10C for -100C or less for K sensors
                           Platinum resistance thermometer inputs:
                           (1% of PV or 2C, whichever is greater) 1 digit max.
                           Analog inputs:
                           (1% of FS) 1 digit max.

    Proportional band (P)  0.1 to 999.9 EU (in units of 0.1 EU)

    Integral time (I)      0 to 3999 s (in units of 1 s) With floating control, 1 to 3999 s

    Derivative time (D)    0 to 3999 s (in units of 1 s)

    Control period         1 to 99 s (in units of 1 s)

    Manual reset value     0.0% to 100.0% (in units of 0.1%)

    Alarm setting range    -1999 to 9999 (decimal point position depends on input type)

    Sampling period        500 ms

    Insulation resistance  20 M min. (at 500 VDC)

    Dielectric strength    2000 VAC, 50 or 60 Hz for 1min (between terminals of different charge)

    Vibration resistance   10 to 55 Hz, 20 m/s2 for 10min each in X,Y, and Z directions

    Shock resistance       100 m/s2, 3 times each in X, Y, and Z directions

    Weight                 Approx. 260 g

    Memory protection      EEPROM (non-volatile memory) (number of writes: 100,000 operations)

                           Emission enclosure:                EN55011 (GB/T 6113.1, 2) 1 group, type A
                           Emission AC mains:                 EN55011 (GB/T 6113.1, 2) 1 group, type A (See note 2.)
                           Immunity ESD:                      IEC61000-4-2 (GB/T 17626.2) 4 kV contact discharge (series 2)

                                                                                                         6 kV air discharge (series 3)

    EMC

                           Immunity RF interference:          IEC61000-4-3 (GB/T 17626.3): 10 V/m, 80 MHz-1 GHz (series)

                           Immunity-conducted disturbance: EC61000-4-6 (GB/T 17626.6): 3 V(0.15-80 MHz) (series 3)

                           Surges (shocks):                   IEC61000-4-5 (GB/T 17626.5): 2 kV power supply line (series 3)

                                                                                             1 kV I/O signal line (series 4)

    Approved standards     UL61010C-1,CSA C22.2 No.1010.1

    Conformed standards    EN61326, EN61010-1 (IEC61010-1)

Note: 1. The indication accuracy of K thermocouples in the -200 to 1300C range, T and N thermocouples at a temperature of -100C max., and
            U and L thermocouples at any temperature is 2C 1 digit maximum. The indication accuracy of the B thermocouple at a temperature
            of 400C max. is not specified. The indication accuracy of the R and S thermocouples at a temperature of 200C max. is 3C 1 digit

            max.

        2. For E5EZ-PRR@03-model products, in order to satisfy the conduction and emission specifications of EN61326CLASSA, a magnetic ring
            (TDK: ZAT1730-0730) should be added to the communications line between the K3SC unit and the controller.

40
                                                                                                                     E5EZ-PRR

Dimensions

Note: All units are in millimeters unless otherwise indicated.

                                                                Panel Cutout

                                                                Mounted Separately  Group Mounted
                                                                           45
                                                                                    (48    number               of  units  -2.5)  +1.0
                                                                                                                                     0

                                                                91                   Recommended panel thickness is 1 to 8 mm.
                                                                  above 120
                                                                                      92 Group mounting is not possible in the vertical
                                                                                                                                                  92direction. (Maintain the specified mounting
                                                                                      space between Controllers.)

                                                                                     When two or more Controllers are mounted,
                                                                                      make sure that the surrounding temperature
                                                                                      does not exceed the allowable operating
                                                                                      temperature specified in the specifications.

Package Content

  1 Temperature Gauge
  2 Metallic Components For Installation
  1 Operating Manual
  1 Quality Certificate

  During removal, please use a screwdriver
  to remove the clips on the top and bottom
  of the front covering panel, and then
  remove the temperature gauge's front
  panel.

Accessories                                  11.8               Terminal Covers (Order Separately)
                                                         4.8
Unit Labels (Order Separately)                                  E53-COV18 (Available only for E5EZ-PRR)

       Y92S-L1 Type                                                                                           3

                                                                44

                                                                                              41
E5EZ-PRR

Wiring Terminals

Standard insulation is appliedto the temperature gauge's I/O sections. If reinforced insulation is required, connect the input and output terminals
  to a device without any exposed current-carrying parts, or to a device with standard insulation suitable for the maximum operation voltage of
  the power supply I/O section.

For E5EZ-PRR@03-model products, in order to satisfy the conduction and emission specifications of EN61326CLASSA, a magnetic ring (TDK:
  ZAT1730-0730) should be added to the communications line between the K3SC unit and the controller.

E5EZ-PRR

                                                                                                          Event Input  Communications                                            Communications

                                                                                                          EV1                         RS232C                                     RS485

                                                                          1                           12               12             SD      12                                 B(+)

100 to 240 VAC 50/60 Hz                                                                               13 EV2           13             RD      13

                                                                          2

                                                       3                                              14               14             SG      14                                 DO NOT
              Control Output 1 (OPEN Output)
                                                                                                                                                                                 USE
                                                       4
              Control Output 2 (CLOSE Output)

                                                       5

                             OPEN                                                      6

Potentiometer                WIPE                                                      7

                           CLOSE                                                       8

                                                                                    A

              +         DO NOT DO NOT                                                  9              20
                                                                                                                      Alarm Output 2
              mA        USE                                                    USE  B
                                                                                                      21
                                                                                       10                 Alarm Output 1

                 DO NOT V                                                                 B           22
                 USE +
                             +                                                              11
                                                                                    Pt
          Analog Input       TC

Nomenclature

E5EZ-PRR

                                                                                    Temperature Unit

                                                                                    The temperature unit is displayed when parameters are set to display a temperature.
                                                                                    The display is determined by the currently selected "temperature unit" parameter set value.
                                                                                    c indicates C and f indicates F.

                                                    Operation Indicators                                  PV           No. 1 Display
                    1. ALM1 (alarm 1)                                                                     SV           Displays the process value or parameter type.
                                                                                                                       Lights for approximately one second during startup.
                       Lights when alarm 1 output is ON.
                       ALM2 (alarm 2)                                                                                  No. 2 Display
                       Lights when alarm 2 output is ON.                                                               Displays the set point, parameter operation read
                    2. OUT1, OUT2 (control output 1, control output 2)                                                 value, or the variable input value.
                       Lights when control output 1 or control output 2                                                Lights for approximately one second during startup.
                       is ON.
                    3. STOP (Stop)                                                                        MV           No. 3 Display
                       Lights when operation is stopped.
                       During operation, this indicator lights when                             MANU                   Displays valve open percentage when valve opening
                       operation is stopped by an event or by using the                                                display is on.
                       RUN/STOP function.                                                                              Nothing will be displayed when valve opening display
                    4. CMW (Communications Writing Control)                                                            is switched off.
                       Lights when communications writing is enabled
                       and is not lit when it is disabled.                                                             Up Key
                    5. MANU (Manual Mode)
                       Lights when the auto/manual mode is set to                                                      Each press of this key increments the value displayed
                       manual mode.                                                                                    on the No. 2 display or advances the setting. Holding
                                                                                                                       the key down speeds up the incrementation.
                                                                    Mode Key
                              Press this key to change parameters                               A                      Automatic/ Manual Key
                              within a setting level.                                             M
                                                                                                                       Press this key for at least one second to switch
                                                                    Level Key                                          between automatic and manual mode.
                             Press this key to move between setting
                             levels. The setting level is selected in                           Down Key
                             the following order: operation level:
                             adjustment level, initial setting level,                           Each press of this key decrements values displayed on the No. 2 display or
                             communications setting level.                                      reverses the setting. Holding the key down speeds up the decrementation.

42
                                                                                                                                         E5EZ-PRR

Operation

Initial hardware setup, including the sensor input type, alarm types, control periods, and other settings is done using parameter displays. The O
and M keys are used to switch between parameters, and the amount of time that you press the keys determines which parameter you move to.
Two typical examples are described as follows.

Explanation of Examples

Changing Parameters

in-t                in-h                     A image means that there
                                             are parameters.
       0                100                  Continue pressing the M key
l.ini               l.ini M                 to change parameters until you
                                             reach the intended parameter.
       M            in-l
                                  Changing Numbers
intl                        0
                      l.ini               c  25  Numeric data and
  onof                                           selections in each screen
  l.ini                       M              0 can be changed by using
                                             100. 0 the U and D keys.
                    intl

                       onof
                      l.ini

Typical Example 1

Input Type : 5K thermocouple -200C to 1300C    Setup Procedure                                    Power ON

                                                        Power ON

Control Method : PID Control                                                     Operation level

Alarm 1 Type : 2 upper limit (deviation)

Alarm Value 1 : 20C (deviation)                                                                    c 25

Set value  : 100C                                                                                           0   Process value/set
                                                                                                        100. .0  value/valve open

                                                                                                                 percentage

                                  Initial setting level                          Initial setting level           Press the L key for at
                                                                                                                 least 3 seconds

                                                                                                                     Control stops.

                                                    Set input                    Check input type.      in-t
                                                 specifications
                                                  Set control                                                 5 Input type 5
                                                 specifications                                          l.ini
                                                  Set alarm
                                                                                                            M
                                                      type
                                                                                 Check alarm type.      alt1 Alarm 1

                                                                                                               2
                                                                                                         l.ini Alarm 2

                                                                                                        M

                                                                                                                 Press the L key for at
                                                                                                                 least 1 second

                                                                                                                     Control starts.

                                                                                 Operation level

                                                                                 Use the U and      c 25 Process value/set value/
                                                                                 D keys to set
                                                                                 the SP to 100C.        100 valve open percentage
                                                                                                       100. .0 100 C

                                                                                                        M

                                                                                 Confirm that           r-5 Running run
                                                                                 control is
                                                                                 running.                 run
                                                                                                        l.ini Stopped stop
                                             Operation level
                                                                                                           M
                                                                      Set alarm
                                                                        values   Use the U and      c al-1 Alarm value 1: 20
                                                                                 D keys to set
                                                                                 the alarm value            20
                                                                                 to 20C.              l.ini

                                                                                                          M

                                                 Start operation                                  Start operation

                                                                                                                                         43
E5EZ-PRR

Typical Example 2                                                                  Power ON

     Input type : 9T thermocouple -200C to 400C
     Control method : PID control
     Calculate PID constants by AT (auto-tuning).
     Alarm 1 type : 2 upper limit
     Set value : 150C

               Setup Procedure

                                    Power ON

                                                                 Operation level                      Process value/
                                                                                                      set value/valve
                                                                                  c 25                open
                                                                                                      percentage
                                                                                                   0
                                                                                             100. .0

    Initial setting level                                        Initial setting level     Press the L key for
                                                                                           at least 3 seconds
                            Set input                                                       Control stops.
                         specifications
                         Set alarm type                          Use the U and in-t

                                                                 D keys to select          9 Input type 9
                                                                                           l.ini
                                                                 the input type.

                                                                                           M

                                                                 Check the                 alt1
                                                                 alarm type.                    2 Alarm 1 type: 2

                                                                                            l.ini

                                                                                           M

                                         PV/SP            25     Operation level           Press theLkey for
                                         after AT is                                       at least 1 second
                                         stopped          100
                                                        100. .0  Use the U              c  25         Process value/
                                                                 and D keys to                        set value/valve
                                                                                           150 open
                                                                 set the SP to             100. .0 percentage 150
                                         The set          25     150C.
                                         point flashes
    Adjustment level                     during           100    Adjustment level          Press the L key for
                                         auto-tuning    100. .0                            less than 1 second
                         AT execution    (AT)
                                         execution.              Execute AT.                  at Execute AT: ON
     Operation level
                                                           at                                 off
                       Set alarm value
                                                           off                             l. adj Cancel AT: OFF
                                                        l. adj
                                         After AT is                                       Press the L key for
                                         stopped                                           less than 1 second

                                                           at    Operation level Control starts

                                         During AT          on   Confirm that           c 25          Process value/
                                         execution      l. adj   the set point is                     set value/
                                                                 150C.                      150      valve open
                                                                                           100. .0    percentage
                                                                 Confirm that
                                                                 control is                   M       Running
                                                                 running.                             run
                                                                                           r-5
                                                                                                      Stopped
                                                                                             run      stop

                                                                                              M

                                                                 Use the U and c al-1
                                                                 D keys to set
                                                                                           30 Alarm       30
                                                                 the alarm value                 value 1
                                                                 to 30C.
                                                                                           M
          Start operation

                                                                                  Start operation

44
                                                                                                                                      E5EZ-PRR

Setting Level Configuration and Key Operations

Parameters are divided into groups, each called a "level." Each of the set values (setup items) in these levels are called a "parameter."
The parameters on the E5EZ-PRR are divided into the following seven levels:

        Started in manual mode        Power ON
                                                Started in automatic mode
             Press the A key
             for at least 1 s.

                                      Operation Level                    Adjustment Level                                     L+ M key:

                                                         Press L key                                  Press the                 PV display flashes
                                                                                                      L+M
                                                         less than 1 s.                               keys               c 25
                                                                                                      for at least 1 s.
                       Press the      Press the                                  Press the L key                              100
                       A key for                                      c 25                                                  100. 0
                                      L key for                                  for at least 1 s;
                       at least 1 s.                                       100   display will flash.                          L*+ M key
                                      at least 1 s.                      100. 0
Manual                                                                           Press the L key for                             for at least 3 s
Mode                                                     See note 1.
                                                                                 at least 3 s.
                                                                                 Control stops.

        Manual                        Initial Setting Level                           Communications  See note 2.
        Control Level                                                                 Setting Level
                                                                                                              Protect Level
                                                                      Press L key

                                                                      less than 1 s.

                                      Press L key                     Input password.
                                      for at least 1 s.               Set value -169

                                                         Advanced Function                    * The time taken to move to the
                                                         Setting Level                           protect level can be adjusted by
                                                                                                 changing the "Move to protect level
                                                                                                 time" setting.

                                                                                                      Control in progress

                                                                                                      Control stopped

                                                                                                      Not displayed for some models
                                                                                                      Level change

Note: 1. When returning from the initial setting level to the operation level, the
            default in the operation level will be displayed.

        2. When returning from the protect level to the operation level, the
            default in the operation level will be displayed.

                                      Control in Progress Control Stopped

Protect level                         Can be set.                                ---

Operation level                       Can be set.                                ---

Adjustment level                      Can be set.                                ---

Manual control level                  Can be set.                                ---

Initial setting level                 ---                                        Can be set.

Advanced function setting level (See note.) ---                                  Can be set.

Communications setting level          ---                                        Can be set.

Note: Set the parameters in the "initial setting/communications protect" under "protect level" to "0", to activate advanced function setting level.
        Of these levels, the initial setting level, communications setting level, and advanced function setting level can be used only when control has
        stopped. Note that controller outputs are stopped when any of these three levels are selected.
        With the exception of operation level, the present level will be displayed. No. 3 display will show the following when settings are being
        changed:

        No. 3 Display                                  Level name
Manual MV                             Manual control level
l.prt                                 Protect level
                                      Operation level
No display                            Adjustment level
la. dj                                Initial setting level
l.ini                                 Communications setting level
l.com                                 Advanced function setting level
la. dv

                                                                                                                                                    45
E5EZ-PRR                         To select this level, simultaneously press the L and M keys for
                                   at least 3 seconds. This level is to prevent unwanted or acciden-
Descriptions of Each Level         tal modification of parameters. Protected levels will not be dis-
                                   played, and so the parameters in that level cannot be modified.
Protect Level
Operation Level                   This level is displayed when you turn the power ON. You can
                                   move to the protect level, initial setting level, manual control level
Adjustment Level                   and adjustment level from this level.

Manual Control Level             Normally, select this level during operation. During operation, the
                                   process value and manipulated variable can be monitored, and
Initial Setting Level              the set points, alarm values, and upper- and lower-limit alarms
                                   can be monitored and modified.
Advanced Function Setting Level
Communications Setting Level      To select this level, press the L key for less than one second.
                                  This level is for entering set values and offset values for control.

                                   This level contains parameters for setting the AT (auto-tuning),
                                   communications writing enable/disable, hysteresis, multi-SP, in-
                                   put shift values, heater burnout alarm (HBA) and PID constants.
                                   You can move to the top parameter of the operation level, initial
                                   setting level and protect level from here.

                                  Pressing the A key under the operation/adjustment level for 1
                                   second or more will activate manual mode, and switch to the
                                   manual control level.
                                   Under manual control, only "process value/set value/valve open
                                   percentage (manual MV)" can be displayed. Under the "process
                                   value/set value/valve open percentage (manual MV)" manual
                                   control level, pressing the A key for 1 second or more will switch
                                   to automatic mode, switch to the operation level, display the de-
                                   fault in the level, and allow manual operation of MV in this mode.

                                  To access this level, press the L key for 3 or more seconds in
                                   the operation level or adjustment level. 1 second later, the PV dis-
                                   play will blink. This level is used to indicate input type and select
                                   control method, control period, direct/reverse operation, and
                                   alarm type. You can move to the advanced function setting level
                                   or communications setting level from this level. Press the L key
                                   for at least 1 second to switch to the operation level. Press the L
                                   key less than 1 second to switch to the communications level.

                                  To activate this level, set the parameters in the "initial setting/
                                   communications protect" under the "protect level" to "0" and then
                                   enter the password ("-169") in the initial setting level.

                                  The initial setting level can be accessed from this level.
                                  This level is for setting the automatic display return time, MV lim-

                                   iter, event input assignment, standby sequence, alarm hystere-
                                   sis, and ST (self-tuning).

                                  To select this level, press the L key less than one second inthe
                                   initial setting level. When the communications function is used,
                                   set the communications conditions in this level. Communicating
                                   with a personal computer (host computer) allows set points to be
                                   read and written, and manipulated variables to be monitored.

46
                                                                                    E5EZ-PRR

Setting the Input Type        The Controller supports four input types: platinum resistance thermometer, thermocouple, infrared
                              temperature sensor, and analog inputs. Set the input type that matches the sensor that is used. In the
    in-t                      product specifications, there are models with thermocouple/resistance thermometer inputs (universal
                              input) and models with analog input. The settings differ depending on the model.
             5 Input Types 5  Check to make sure which model you are using.
       l.ini
                              List of Input Types

                                 Input Type  Specifications   Set value          Input temperature setting range
                              Platinum                             0          -200 to 850 (C) / -300 to 1500 (F)
                              Resistance           Pt100           1     -199.9 to 500.0 (C) / -199.9 to 900.0 (F)
                              Thermometer                          2          0.0 to 100.0 (C) / 0.0 to 210.0 (F)
                                                  JPt100           3     -199.9 to 500.0 (C) / -199.9 to 900.0 (F)
                              Thermocouple                         4          0.0 to 100.0 (C) / 0.0 to 210.0 (F)
                                                      K            5        -200 to 1300 (C) / -300 to 2300 (F)
                              Infrared                             6      -20.0 to 500.0 (C) / 0.0 to 900.0 (F)
                              temperature             J            7          -100 to 850 (C) / -100 to 1500 (F)
                              sensor,                              8      -20.0 to 400.0 (C) / 0.0 to 750.0 (F)
                              ES1B                    T            9          -200 to 400 (C) / -300 to 700 (F)
                                                      E           22     -199.9 to 400.0 (C) / -199.9 to 700.0 (F)
                                                      L           10
                                                      U           11               0 to 600 (C) / 0 to 1100 (F)
                                                      N           12          -100 to 850 (C) / -100 to 1500 (F)
                                                      R           23          -200 to 400 (C) / -300 to 700 (F)
                                                      S           13     -199.9 to 400.0 (C) / -199.9 to 700.0 (F)
                                                      B           14        -200 to 1300 (C) / -300 to 2300 (F)
                                              10C to 70C        15
                                             60C to 120C        16             0 to 1700 (C) / 0 to 3000 (F)
                                             115C to 165C       17             0 to 1700 (C) / 0 to 3000 (F)
                                             140C to 260C       18          100 to 1800 (C) / 300 to 3200 (F)
                                                                  19
                                                                  20                0 to 90 (C) / 0 to 190 (F)
                                                                                   0 to 120 (C) / 0 to 240 (F)
                              Analog Input        0 to 50 mV  21                   0 to 165 (C) / 0 to 320 (F)
                                                                                   0 to 260 (C) / 0 to 500 (F)
                                                                            Either of the following ranges, by scaling:
                                                                                 -1999 to 9999 or -199.9 to 999.9

                              The default is "5"

                              Analog Input   Input Type  Specifications  Set value      Input temperature setting range
                              Type           Current     4 to 20 mA           0
                                             Input       0 to 20 mA           1     Use the following scales based on the
                                                         1 to 5 V             2     range of measurements:
                                             Voltage     0 to 5 V             3     -1999 to 9999
                                             Input       0 to 10 V            4     -199.9 to 999.9
                                                                                    -19.99 to 99.99
                                                                                    -1.999 to 9.999

                              The default is "0"

                                                                                                                                      47
E5EZ-PRR

Alarm Types

Alarm outputs are determined by a combination of "alarm type," "alarm value," and "alarm hysteresis" alarm output conditions.
This section describes the "alarm type," "alarm value," "upper-limit alarm" and "lower-limit alarm" parameters.

    alt1      Alarm1    Set                    Type                                  Alarm output operation
              Type 2  values
           2                                                                    When X is positive When X is negative
     l.ini
                      0 Alarm function OFF                                                         Output OFF

                          1        Upper-and lower-limit                        ON      LH                See note 2.
                                                                                OFF      SP
                      See note 1.

                                                                                ON              X         ON                      X

                      2 Upper-limit                                             OFF     SP                OFF                     SP

                      3 Lower-limit                                             ON      X                 ON                         X
                                                                                OFF      SP               OFF
                          4        Upper-and lower-limit range                  ON      LH
                                                                                OFF      SP                              SP
                      See note 1.                                                                         See note 3.

                          5        Upper-and lower-limit with standby sequence  ON      LH                See note 4.
                                                                                OFF      SP (See note 5)
                      See note 1.                                               ON
                                                                                OFF        X
                      6 Upper-limit with standby sequence                               SP                ON                      X

                                                                                                          OFF                     SP

                      7 Lower-limit with standby sequence                       ON      X                 ON                         X
                                                                                                          OFF
                                                                                OFF     SP
                                                                                                                         SP

                      8 Absolute-value upper-limit                              ON         X              ON                         X
                      9 Absolute-value lower-limit
                      10 Absolute-value upper-limit with standby sequence       OFF  0                    OFF                           0
                      11 Absolute-value lower-limit with standby sequence
                                                                                ON      X                 ON                      X
                                                                                OFF                       OFF

                                                                                     0                                                  0

                                                                                ON         X              ON                         X

                                                                                OFF  0                    OFF
                                                                                                                               0

                                                                                ON      X                 ON                      X
                                                                                OFF                       OFF

                                                                                     0                                                  0

                      Note 1. Upper and lower-limit values can be set independently for each alarm type, and are
                                expressed as L and H. The set values are 1, 4, and 5.

                             2. Set value: 1 (Upper-and lower-limit alarm)

                      Case 1                   Case 2           Case 3 (Always ON)

                            L H SP               SP L H           L SP H             H < 0, L < 0
                            H< 0.L >0            H> 0.L <0      H LSP
                             |H| < |L|             |H| > |L|                         H < 0, L > 0
                                                                        SP H L         |H|  |L|

                                                                                     H > 0, L < 0
                                                                                       |H|  |L|

                      3. Set value: 4 (Upper-and lower-limit range)

                      Case 1                   Case 2           Case 3 (Always OFF)

                                   L H SP      SP L H             L SP H             H< 0.L <0
                                                                H L SP
                                   H< 0.L >0   H> 0.L <0                             H< 0.L <0
                                    |H| < |L|   |H| > |L|                             |H|  |L|

                                                                SP H L               H< 0.L <0
                                                                                      |H|  |L|

                      4. Set value: 5 (Upper-and lower-limit with standby sequence)

                               The upper and lower limit alarms described above.
                               In cases 1 and 2, if there is significant overlap between the upper and lower limit values

                               after hysteresis, the alarm will always be OFF.
                               Examples of case 1 and 2: In case 3, under general conditions, the alarm is turned OFF.

                      5. Set value: 5 (Upper-and lower-limit with standby sequence)

                         If there are any overlaps in the upper and lower limits for hysteresis, the alarm will always
                         be OFF.

                         There are alarm types 1 to 2 (initial setting level), and settings should be made
                         independently for each alarm.
                         The default is 2: upper limit.

48
                                                                                                                                        E5EZ-PRR

Parameters

Parameters related to setting items for each level are marked in boxes in the following flowchart and brief descriptions are given as required. After
finishing each setting, press the mode key to return to the beginning of each level.

        Started in manual mode                Power ON
                                                        Started in automatic mode

        Press A key for at least 1 s.

                                              Operation Level                    Adjustment Level                                     L+ M key:

                                                                 Press L key                                  Press the                 PV display flashes
                                                                                                              L+M
                                                                 less than 1 s.                               keys               c 25
                                                                                                              for at least 1 s.
                       Press A key for        Press the                                  Press the L key                              100
                       at least 1 s.          L key for                       c 25                                                  100. 0
                                              at least 1 s.                              for at least 1 s;
                                                                                   100   display will flash.                          L*+ M key
Manual                                                                           100. 0
Mode                                                                                     Press the L key for                             for at least 3 s
                                                                 See note 1.
                                                                                         at least 3 s.
                                                                                         Control stops.

        Manual                                Initial Setting Level                           Communications     See note 2.
        Control Level                                                                         Setting Level
                                                                                                                         Protect Level
                                                                              Press L key

                                                                              less than 1 s.

                                              Press L key                     Input password.
                                              for at least 1 s.               Set value -169

                                                                 Advanced Function              * The time taken to move to the
                                                                 Setting Level                     protect level can be adjusted by
                                                                                                   changing the "Move to protect level
                                                                                                   time" setting.

                                                                                                                 Control in progress

Note 1: When returning from the initial setting level to the operation level, the                                Control stopped
           default in the operation level will be displayed.                                                     Not displayed for some models
                                                                                                                 Level change
       2: When returning from the pro tect level to the o peration level, the de-
           fault in the operation level will be displayed.

Display                25                     No. 1 Display
                                              No. 2 Display
                 c                            No. 3 Display

                         0
                    100 0

                            Press the key     Initial setting level           Press the key       Power ON       Press the key          Adjustment level
                            for at least 1 s                                  for at least 1 s  Operation level  for less than 1 s

Advanced function                                                             Press the key                      Press the key
    setting level                                                             for at least 3 s                   for less than 1 s

                                              Note: To select the advanced function
                                                       setting level, you must input the
                                                       password (-169) in the initial
                                                       setting level.

                                                                                                                                                            49
E5EZ-PRR

Parameter Flow

In each level, if you press the mode key on the final parameter, you will return to the parameter at the top of the level.

    Advanced function setting level                                                                       Initial setting level

    init                                                a1lt                                              in-t
      off Parameter initialization                        off Alarm 1 latch                                    5 Input type

    l.                                                  l.                                                l.ini

             Number of multi-SP                         a2lt Alarm 2 latch                  Activate      in-h
             uses                                          off                              alarm latch     100 Scaling upper limit
             Select 2 or 4.
    en-m                                                l.                                                l.ini
         1

    l.

             Event input assignment 1 Input setting:                                                      in-l                             For analog input
                                                                                                               0 Scaling lower limit
    none                             Multi-SP/RUN/      prlt       Move to protect level time
                                                             3                                            l.ini
    l.                               STOP
                                                        l.

    stop Event input assignment 2                       sero                                                 dp     Decimal point
    l.                                                     off Input error output                              0

                                                        l.                                                l.ini

    ospu Multi-SP uses                                   cjc       Cold junction                          d-u       Temperature unit C / F
                                                           on      compensation method                                 is Celsius, and is Fahrenheit
    l.  off  on off                                                                                            c
                                                        l.                                                l.ini

    rest     Standby sequence reset                                                                       Csl-h     SP upper limit
             Reset conditions after
        a standby sequence is                                                                                1300
    l.       canceled.                                    off MB command logic switching                    l.ini
                                                        l.                                                                                 Limit the set point

      al1n Alarm 1 open in alarm                        a1on       Alarm 1                                Csl-l     SP lower limit
         n-o                                                       ON delay                                  -200
                                     ON/OFF setting          0                                               l.ini
      l.                             of alarm output 1  l.

    Calh1                                               a2on       Alarm 2                                           Direct / reverse operation
          0 2 Alarm 1 hysteresis                                   ON delay                                          Direct operation: on-d
                                                             0                                            l.ini Reverse operation: or-r
       l.                                               l.

      al2n Alarm 2 open in alarm                        a1of       Alarm 1                  Alarm ON/OFF  alt1
         n-o                                                       OFF delay                delays             2 Alarm 1 type
                                                             0
       l.                            ON/OFF setting     l.                                                l.ini
                                     of alarm output 2
    Calh2                                                                                                                                  Select alarm mode
          0 2 Alarm 2 hysteresis
                                                        a2of Alarm 2                                      alt2      Alarm 2 type
      l.                                                                                                       2
                                                             0     OFF delay
                                                        l.                                                l.ini

    alfa                                                          Additional MV                           clfl Closed / floating
             2 PID parameters                                                                                       Floating: flot
      0.65                                                off for stop/error                              flot      Closed: clos
    l.                                                  l.                                                l.ini

     inf     Input digital filter                       Cp-db      Process value dead band                calb      Motor calibration
                  Set the time constant,                                                                            Motor calibration: on
       00         in units of s                                 0                                            off    Cancel: off
    l.                                                    l.                                               l.ini

             Additional PV display                                                                         mot
                                                                                                             30 Travel time
      off    Displayed first in the operation level         on Valve opening display
    l.                                                  l.                                                l.ini

     ret     Automatic display return time              oanl Manual MV                                               Switch to advanced function setting level
      off        Automatic return to operation              on Limits in effect                                      To switch to the advanced function
    l.           level when the keys on the front                                                             0 setting level, the initial setting/
                 panel are operated.                    l.                                                           communications protect parameters
                                                                                                                     must be set to 0.

50
                                                                                                                                         E5EZ-PRR

Operation level                                           Adjustment level

C 25                        Added when                       at      AT execute/cancel                                MV at stop
             Process value  Additional PV                            AT execute: on                                   Hold: hold
                            display is ON.                  off      AT cancel: off                                   Open: open
                                                          l.adj                                             l.adj     Close: close

C 25       Process value/                                 cmwt       Communications writing                 l.adj     MV at PV error
           set value/valve                                  off      Enabled: on                                      Hold: hold
        0  open percentage                                           Disabled: off                                    Open: open
   1000.                                                  l.adj                                                       Close: close

m-sp                                                      Csp-0      SP 0                                   Csprt     SP ramp set value
     0 Multi-SP set point setting                                 0
                                                                                                                 off
                                                             l.adj                                             l.adj

C sp-m     Set point during SP ramp                       Csp-1      SP 1                                   ol-h
        0                                                                                                    1000. MV upper limit
                                                                  0                          SP used by                                  MV limit value
                                                            l.adj                            Multi-SP       l.adj

              RUN/STOP                                    Csp-2      SP 2                                   ol-l      MV lower limit
              Run: run
              Stop: stop                                          0                                            0.0
                                                            l.adj                                           l.adj
C al-1
        0 Alarm value 1                                   Csp-3      SP 3                                      db     Position proportional dead band

                                                                  0                                             20
                                                            l.adj                                           l.adj

Cal1h      Alarm value               Set either of these  C in5      Temperature             1 point shift  oc-h      Open/ close hysteresis
        0  upper-limit 1             parameters                      input shift values                        0. 8
                                                                00
                                                             l.adj                                          l.adj

Cal1l      Alarm value                                    Cin5h      Upper-limit
        0  lower-limit 1                                             temperature shift
                                                                 00  (When using a Infrared
                                                             l.adj   temperature sensor)

                                                                                             2 point shift

Cal-2      Alarm value 2                                  Cin5l      Lower-limit
        0                                                            temperature shift
                                                                00   (When using a
                                                             l.adj   Infrared temperature
                                                                     sensor)

Cal2h      Alarm value               Set either of these  Cp         Proportional band
        0  upper-limit 2             parameters
                                                                80
                                                            l.adj

C al2l     Alarm value                                        i Integral time                PID settings
        0  lower-limit 2                                    233 (Unit: seconds)
                                                          l.adj

                                                              d      Derivative time
                                                                     (Unit: seconds)
                                                             40
                                                          l.adj

                                                                                                                                                         51
E5EZ-PRR

    Protect level                    Operation/ Adjustment Protect

                                     The following table shows the relationship between set values and the range of protection.

    oapt     Operation /                  Level                                                  Set value
             adjustment protect
          0                                                 0                      1                        2                         3
    l.prt

                                                PV Can be displayed Can be displayed Can be displayed Can be displayed

    icpt     Initial setting /       Operation  PV/SP     Can be displayed         Can be displayed  Can be displayed        Can be displayed
             communications          level      Others    and changed              and changed       and changed
          1  protect
    l.prt                                                 Can be displayed         Can be displayed  Cannot be displayed Cannot be displayed
                                                          and changed              and changed       and moving to other and moving to other
    wtpt                                                                                             levels is not possible levels is not possible

       off   Setting change protect                                                Cannot be displayed Cannot be displayed Cannot be displayed
    l.prt                                                                          and moving to other and moving to other and moving to other
                                     Adjustment level     Can be displayed         levels is not possible levels is not possible levels is not possible
                                                          and changed

    keyp     Automatic/ manual       Parameters are not protected when the set value is set to 0.
             key protect
       off                            The default is 0.
    l.prt

                                     Initial Setting/ Communications Protect

                                     This protect level restricts movement to the initial setting level, communications setting level, and advanced
                                     function setting level.

                                     Set value Initial setting level        Communications setting level    Advanced function setting level
                                                                            Movement possible               Movement possible
                                     0          Movement possible           Movement possible               Movement not possible
                                                                            Movement not possible           Movement not possible
                                     1          Movement possible

                                     2          Movement not possible

                                     The default is 1.

                                     Setting Change Protect

                                     This protect level restricts key operations.

                                     Set value                                        Description

                                     OFF         Settings can be changed using key operations.

                                     ON          Settings cannot be changed using key operations. (The protect level settings, however, can be
                                                 changed.)

                                     The default is OFF.

                                     Automatic/ Manual Key Protect

                                     This protect level restricts key operations.

                                     Set value                                        Description

                                     OFF         Settings can be changed between automatic and manual mode using A key operations.

                                     ON          Settings cannot be changed between automatic and manual mode using A key operations. (The
                                                 protect level settings, however, can be changed.)

                                     The default is OFF.

    Communications setting level     Setting Communications Parameters
      u-no
            1 Communications          Each parameter is enabled when the power is reset.
       l.com Unit number               Match the communications specifications of the E5EZ-PRR and the host computer. If multiple devices are

                                        connected, ensure that the communications specifications for all devices in the system (except the
                                        Communications unit number) are the same.

                                          Parameters        Symbol     Set (monitor) values          Settings                Default     Unit
                                     Communications          u-no
    bps      Baud rate               Unit number                       0 to 99                                            1           None
                                                              bps
       96                            Baud rate                len                                    1.2, 2.4, 4.8, 9.6,
    l.com                                                    sbit                                    19.2
                                     Data length             prty
    len      Data length             Stop bits                         1.2, 2.4, 4.8, 9.6, 19.2      none, even, odd      9.6         Kbps
                                     Parity
          7                                                            7, 8                                               7           Length
    l.com                                                              1, 2                                               2           Bit
                                                                       None, even, odd                                    Even        None

    sbit
         2 Stop bits

    l.com

              Parity

    l.com

52
                                            E5EZ-PRR

Error Displays      When an error occurs, the error contents are shown on the No.1 display.
                    This section describes how to check error codes on the display, and the actions
                    to be taken to remedy the problems.

5.err Input Error

Meaning             The input v alue has e xceeded the input indication r ange(-1999 (-199.9) to
Action              9999 (999.9)).

Operation at Error  Check the wiring of inputs for miswiring, disconnections, and short-circuits and
                    check the input type.
                    If no abnormality is found in the wiring and input type, turn the power OFF then
                    back ON again.
                    If the display remains the same, the Controller must be replaced. If the display is
                    restored, then the probable cause is electrical noise affecting the control system.
                    Check for electrical noise.

                    After an error occurs, the error is displayed and the alarm outputs function as if
                    the upper limit has been exceeded.
                    When the "input error output" parameter in the advanced function level is set to
                    ON, the alarm 1 output turns ON whenever an input error occurs.
                    An error message is displayed when the PV or PV/SV/valve open percentage is
                    displayed.
                    Note. When the manual MV, MV at stop , or MV at PV error is set, th e control
                    output corresponds to the set value.

                    Display Range Exceeded

Meaning             Though this is not an error, it is displayed if the process value exceeds the dis-
Operation at Error  play range when the control range is larger than the display range.
                    The display ranges are shown below.
                     When less than -1,999 (-199.9) [[[[
                     When more than 9,999 (999.9) ]]]]

                    Control continues, allowing normal operation. The message is displayed when
                    the PV or PV/SV/valve open percentage is displayed.

                                                                                                         53
E5EZ-PRR

    Platinum resistance thermometer input (Except for models with             Platinum resistance thermometer input (Except for models with
                                                                              a setting range of -199.9. to 500.0C)
    a setting range of -199.9 to 500.0C)                                     Thermocouple input (Except for models with a setting range of
                                                                              -199.9 to 400.0C)
    Thermocouple input (Except for models with a setting range of
                                                                                                                  Control range
    -199.9 to 400.0C)

    ES1B  Control range

    s.err display Numeric display s.err display                               s.err display [[[[ display     Numeric display                             s.err display
                        Input indication range                                                             Input indication range

    Analog (current, voltage) Input                                                                        Analog Input
    When display range < control range                                                                   When display range > control range

                                                      Control range                                                             Control range

    s.err display [[[[ display              Numeric display                   ]]]] display  s.err display  s.err display Numeric display                 s.err display
                                          Input indication range                                                                 Input indication range
                                                                                                                                                             9999
                                 -1999     Display range              9999                                  -1999    Display range                         (999.9)
                                (-199.9)                             (999.9)                               (-199.9)

    e111                        Memory Error

Meaning                                                              Internal memory operation is in error.
Action                                                               First, turn the power OFF then back ON again. If the display remains the same,
                                                                     the Controller must be repaired. If the display is restored, then the probable
                                                                     cause is electrical noise affecting the control system. Check for electrical noise.

Operation at Error                                                   Control output and alarm output turn OFF.

    ----                        Potentiometer Input Error

Meaning                                                              Valve opening has exceeded its regular range of -10% to 110%.
Action
                                                                     Check to see if there have been any wiring errors, burnouts, or short-circuits in
Operation at Error                                                   the potentiometer.
                                                                     If there are no problems with the wiring, you can restart the power supply. If the
                                                                     display remains the same, the Controller must be replaced. If the display is re-
                                                                     stored, then the probable cause is interference which should be avoided.

                                                                     Control output will output MV based on the "MV during error" setting position.
                                                                     Alarm output will operate as normal.

    err                         Motor Calibration Error

Meaning                                                              Motor calibration did not completely finish.
Action
Operation at Error                                                   After confirming the potentiometer and the wiring of the motor driving valve, per-
                                                                     form motor calibration again.

                                                                     Control output and alarm output set to OFF.

54
                                                                                               E5EZ-PRR

Position proportional control of a ceramic kiln

The control method whereby a potentiometer is used to read the amount of opening of a valve and then open or close the valve by means of an
attached control motor is called position proportional control or on/off servo control.

Application

                                             To control a gas kiln using a position proportional control valve, select the control valve control type and
                                             configure the instrumentation as shown in the following example.

Temperature Input

Analog Input                           Potentiometer

                                                             SP

                   PV                                                                                               SP ramp

                                                      SP after change

SP SP Ramp                                                                                                                                           SP ramp
                                  PID                                                                                                                set value
                                  MV                                                                                         SP ramp in units of time

                                                      SP before change                                                                                 Time
                                                                                 Point of change
OUT1                                   OUT2

                                                      E5EZ-PRR
                                                          8 8 8 8 PV
                                                            8 8 8 8 SV
                                                            8 8 8 8 MV

                                                                                                              MANU
                                                                                          A
                                                                                             M

                                                                                                                             Temperature
                                                                                                                             Sensor

                                                                                                                    Burner

                                                      Note:  The SP ramp function allows limits to be placed on temperature changes which
                                                             control the temperature within a specific range. This is useful for ceramic kiln,
                                                             in which severe temperature changes may cause damage or corruption.

                                                                                                                                                                55
E5EZ-PRR

Wiring

                                                  Input should be connected to terminals 9, 10, and 11 depending on input type. Connect the open
                                                  side of the position proportional valve to OUT1, and connect the closed side to OUT2.

                                                                                                          1             12

                                                                                                          2             13

                                                                                                          3             14

                                                  Ceramic kiln                                            4
                                                  (combustion)

                                                                    Sensor    C WO                        5

                                                                             CLOSE
                                                                             OPEN
                                                                             Valve

                                                                                                          6

                                                                                                          7

                                                                                                          8

                                                                     Burner  Position proportional valve  9             20

                                                                                                          10            21

                                                                                                          11            22

Settings

                                                  Select the value control type and perform floating control using Position-proportional value with travel
                                                  time* of 45 seconds. Set SP ramp to change SP within a width of 10.0C/minute.
                                                  *Time from completely open to completely close.

                                                  The related setting data and settings are as follows:

                                                  Direct/ reverse operation         = or-r: Reverse operation (initial setting)

                                                  Closed/ floating                  = flot: Floating (initial setting)

                                                  Travel time                       = 45 seconds

                                                  SP ramp set value                 = "10"

    in-t                                          The travel time and SP ramp set value are set in the following, and the initial settings are used for
                                                  all other parameters.
           5
    l.ini                                         1. Press the L key for at least 3 seconds to switch from the operation level to the initial setting
                                                      level.

               Travel time

    mot

    30                45                          2. Press the M key repeatedly to select "mot: Travel time". Press the U key to set the value to
                                                      "45".
    l.ini U

    Operation level                               3. Press the L key for at least 1 second to return to the "operation level". When "present value/
                                                      set value/valve open percentage" is displayed, press the U key to set the set value to "250".
                       Process value/ set value/

         25 valve open percentage

    0                 25 0

    100.0 U

    Adjustment level

      at                                          4. Press the L key for less than 1 second to switch from operation level to adjustment level.

      off                                         5. Press the M key repeatedly to select sprt: SP ramp set value. Press the U key, to set the
    l.adj                                             value to "10".

    sprt SP ramp set value

           0 10
     l.adj U

56
                                                                        E5EZ-PRR

Adjustment                              To adjust the PID constants, run AT.
                                        When position proportional control is selected, "Closed/Floating", "Motor calibra-
Settings for position                   tion", "Travel time", "Position proportional dead band", "Open/Close hysteresis",
proportional control                    "Operation at potentiometer input error", and "PV dead band" can be used.

Closed/Floating                         Closed control
                                            Control whereby a potentiometer is connected to feed back the amount of
                                            opening of the valve.

                                        Floating control
                                            Control without feedback of the amount of opening of the valve. Control is
                                            possible without connecting a potentiometer.

Motor calibration and travel time       Run "Motor calibration" when a potentiometer is connected for closed control or
                                        floating control that monitors the amount of valve opening.
                                        This will also automatically set the "Travel time", which is the amount of time from
                                        when the valve is completely open to when the valve is completely closed.
                                        When performing floating control without a potentiometer, it is necessary to man-
                                        ually set the "Travel time". Set the travel time to the amount of time from when
                                        the valve is completely open to when the valve is completely closed.

Position proportional dead band and     The valve output hold interval (the duration of ON/OFF switching of open output
Open/Close hysteresis                   and closed output) is set in "Position proportional dead band", and the hysteresis
                                        is set in "Open/Close hysteresis".
                                        The relation to valve opening is shown below.

                                                 Open/close hysteresis
                                                          Dead band

                                        ON       0                      MV-Valve opening  100%
                                        OFF

                                          -100%

PV dead band                            When the present value is inside the PV dead band, this function is used to per-
                                        form control for PV = SP and stop unnecessary output when the PV is close to
                                        the SP.

Operation at potentiometer input error  Use this setting to select whether to stop control or switch to floating control and
                                        continue when a potentiometer error occurs during closed control.

                                                                                                                              57
E5EZ-PRR

Meeting all of your temperature control needs in a wide range of
applications

ES1B Infrared Temperature Sensor

Perform measurements with a contract-free sensor at minimal costs!

                                           Outputs electromotive forces identical to those of thermocouples, so that it can be connected
                                            directly to temperature controllers that generally use thermocouple input.

                                           4 types of specifications. Can be used in all types of temperature measurements, from food
                                            products, packaging, and finished product, all the way to electrical engineering.

                                           300 ms high-speed response (63% response time), 1% and PV's reenactment capabilities,
                                            ensuring high-accuracy temperature measurements.

                                           Compared to thermocouples, this product has the advantage of being resistant to aging, and can
                                            maintain steady real-time control.

Note: For more detailed information, please refer to other ES1B-related materials.

                            Shape, visual features               40 mm  60 mm           Specifications      Type
                                                                               (temperature testing range)  ES1B
                                                     2 mm 20 mm
                                                                                           10 to 70C

                                                                                          60 to 120C

                                                                                         115 to 165C

                                                                               140 to 260C

                            2            20                      40     60

ES1-L Series of Infrared Temperature Sensors

Able to measure temperatures without contact.
Damage-free, clean, and effective temperature management.

Comes in two spot diameters: 3 mm dia. and 8 mm dia.
Recreation accuracy kept within 0.5C, with a response speed of 0.4

  seconds (95%), along with high accuracy, realizing fast measurement.
In addition to the original unit for use in medium temperatures (0 to

  +500C), there are new models for use in medium to low temperatures
  (-50 to +500C) and high temperatures (0 to +1000C).
New long distance types enable measuring from distances of 500 mm and
  1000 mm.
By using a programmer (order separately), it is possible to monitor
  temperatures as well as make changes to the rate of emissions, switches
  between functions, and range of output.
  (The picture shows a programmer installed onto an ES1 unit.)

    Type                    Range of temperature                        Spot dimensions (See note 2.)             Type
                                measurements
                                                                                                            ES1-LW100H
    For use with high       0 to +1,000C                        35 mm dia. (distance of 1000 mm)           ES1-LW50H
    temperatures                                                 Below 40 mm dia. (distance of 500 mm)      ES1-LW100
                                                                                                            ES1-LW50
    For use with medium to  -50 to +500C (See note 1.) 35 mm dia. (distance of 1000 mm)                    ES1-LP3
    low temperatures                                                 Below 40 mm dia. (distance of 500 mm)  ES1-LP10

    For use with medium     0 to +500C                          3 mm dia. (distance of 30 mm)
    temperatures                                                 8 mm dia. (distance of 100 mm)

Note: 1. At the time of shipment, the ES1-PRO model's range will have to be changed for
            0 to +500C, -50C.

        2. This value is based on the energy restriction of 90%. The actual item must be at
            least 1.5 times larger.

Note: For more detailed information, please refer to other ES1-L-related materials.

E52 Series of Temperature Sensors

Providing a diverse array of high-accuracy temperature sensors

Used as a sensor for temperature controllers.
Guaranteed that clients will be able to easily select the right model according to

  their temperature, location, and ambient operating conditions.
Able to provide numerous models of various different categories, cases,

  lengths, and terminal shapes.
Able to provide low-cost made-to-order models, as well as models for universal

  use.

Note: For more detailed information, please refer to other E52-related materials.

58
Safety Precautions                                                                                           E5EZ-PRR

                            !CAUTION                                    Precautions for Safe Use

Do not touch the terminals while power is being supplied.               Be sure to observe the following precautions to prevent operation
Doing so may occasionally result in minor injury due to                 failure, malfunction, or adverse affects on the performance and
electric shock.                                                         functions of the product. Not doing so may occasionally result in
                                                                        unexpected events.
Operate the Temperature Controller properly. Improper                   1. The product is designed for indoor use only. Do not use the
operation may cause minor or moderate injury or property
damage.                                                                     product outdoors or in any of the following locations.

Do not allow pieces of metal, wire clippings, or fine                        Places directly subject to heat radiated from heating equipment.
metallic shavings or filings from installation to enter the
product. Doing so may occasionally result in electric                        Places subject to splashing liquid or oil atmosphere.
shock, fire, or malfunction.
                                                                            Places subject to direct sunlight.
Do not use the product where subject to flammable or
explosive gas. Otherwise, minor injury from explosion                        Places subject to dust or corrosive gas (in particular, sulfide gas
may occasionally occur.                                                       and ammonia gas).

Never disassemble, modify, or repair the product or touch                   Places subject to intense temperature change.
any of the internal parts. Minor electric shock, fire, or
malfunction may occasionally occur.                                          Places subject to icing and condensation.

CAUTION - Risk of Fire and Electric Shock                                    Places subject to vibration and large shocks.
a) This product is UL listed as Open Type Process
                                                                        2. Use and store the product within the rated temperature and
    Control Equipment. It must be mounted in an                             humidity ranges.
    enclosure that does not allow fire to escape externally.                Group-mounting two or more Temperature Controllers, or
b) More than one disconnect switch may be required to                       mounting Temperature Controllers above each other may cause
    de-energize the equipment before servicing the                          heat to build up inside the Temperature Controllers, which will
    product.                                                                shorten their service life. In such a case, use forced cooling by
c) Signal inputs are SELV, limited energy. (See note 1.)                    fans or other means of air ventilation to cool down the
d) Caution: To reduce the risk of fire or electric shock, do                Temperature Controllers.

                not interconnect the outputs of different Class         3. To allow heat to escape, do not block the area around the product.
                2 circuits. (See note 2.)                                   Do not block the ventilation holes on the product.

If the output relays are used past their life expectancy,               4. Use the specified size (M3.5, width of 7.2 mm or less) crimped
contact fusing or burning may occasionally occur. Always                    terminals for wiring. To connect bare wires to the terminal block,
consider the application conditions and use the output                      use copper braided or solid wires with a gage of AWG24 to
relays within their rated load and electrical life                          AWG14 (equal to a cross-sectional area of 0.205 to 2.081 mm2).
expectancy. The life expectancy of output relays varies                     (The stripping length is 5 to 6 mm.) Up to two wires of the same
considerably with the output load and switching                             size and type, or two crimp terminals can be inserted into a single
conditions.                                                                 terminal.

Loose screws may occasionally result in fire.                           5. Be sure to wire properly with correct polarity of terminals. Do not
Tighten terminal screws to the specified torque of 0.74 to                  wire any of the I/O terminals incorrectly.
0.90 Nm.
                                                                        6. Do not wire the terminals that are not used.
Unexpected operation may result in equipment damage                     7. The voltage output (control output) is not electrically isolated from
or accidents if the settings are not appropriate for the
controlled system. Set the Temperature Controller as                        the internal circuits. When using a grounded temperature sensor,
follows:                                                                    do not connect any of the control output terminals to ground.
                                                                            Otherwise unwanted current paths will cause measurement
A malfunction in the Temperature Controller may                             errors.
occasionally make control operations impossible or                      8. To avoid inductive noise, keep the wiring for the Temperature
prevent alarm outputs, resulting in property damage.                        Controller's terminal block away from power cables carrying high
To maintain safety in the event of malfunction of the                       voltages or large currents. Also, do not wire power lines together
Temperature Controller, take appropriate safety                             with or parallel to Temperature Controller wiring. Using shielded
measures, such as installing a monitoring device on a                       cables and using separate conduits or ducts is recommended.
separate line.                                                              Attach a surge suppressor or noise filter to peripheral devices that
                                                                            generate noise (in particular, motors, transformers, solenoids,
Be sure that the platinum resistance thermometer type                       magnetic coils or other equipment that have an inductance
and the input type set on the Temperature Controller are                    component).
the same.                                                                   When a noise filter is used at the power supply, first check the
                                                                            voltage or current, and attach the noise filter as close as possible
Note: 1. A SELV circuit is one separated from the power supply with         to the temperature controller.
            double insulation or reinforced insulation, that does not       Allow as much space as possible between the Temperature
            exceed 30 V r.m.s. and 42.4 V peak or 60 VDC.                   Controller and devices that generate powerful high frequencies
                                                                            (high-frequency welders, high-frequency sewing machines, etc.)
        2. A class 2 power supply is one tested and certified by UL as      or surge.
            having the current and voltage of the secondary output      9. To reduce the risk of fire or electric shock, install the Temperature
            restricted to specific levels.                                  Controller in a controlled environment relatively free of
                                                                            contaminants.
                                                                        10.The outputs may turn OFF when shifting to certain levels. Take
                                                                            this into consideration when performing control.
                                                                        11.When turning OFF the power, use a switch or relay to ensure the
                                                                            voltage decreases immediately. Incorrect operation and data
                                                                            storage errors may occur if the voltage decreases slowly.
                                                                        12.Make sure that any Option Units are installed correctly. Do not
                                                                            remove the internal PCB when installing an Option Unit.
                                                                        13.When inserting the Temperature Controller into the case, do not
                                                                            force it into the case. Doing so will damage internal parts.
                                                                        14.The EEPROM has a limited write life. When overwriting data
                                                                            frequently, e.g., via communications, use RAM Mode.
                                                                        15.Use the product within the rated load and power supply.
                                                                        16.Use a switch, relay, or other contact so that the power supply
                                                                            voltage reaches the rated voltage within 2 seconds. If the applied
                                                                            voltage is increased gradually, the power supply may not be reset
                                                                            or malfunctions may occur.

                                                                        59
E5EZ-PRR

17.When using PID operation (self-tuning), turn ON the power supply           Precautions for Correct Use
    to the load (e.g., heater) at the same time or before turning the
    power supply to the Temperature Controller ON. If power is turned         Service Life
    ON for the Temperature Controller before turning ON power
    supply to the load, self-tuning will not be performed properly and        1. Use the product within the following temperature and humidity
    optimum control will not be achieved.                                         ranges:

18.Design the system (e.g., control panel) to allow for the 2 seconds             Temperature: -10 to 55C (with no icing or condensation)
    of delay required for the Temperature Controller's output to
    stabilize after the power is turned ON.                                       Humidity: 25% to 85%

19.A switch or circuit breaker should be provided close to this unit.             If the product is installed inside a control board, the ambient
    The switch or circuit breaker should be within easy reach of the              temperature must be kept to under 55C, including the
    operator, and must be marked as a disconnecting means for this                temperature around the product.
    unit.
                                                                              2. The service life of electronic devices like Temperature Controllers
20.Approximately 30 minutes is required for the correct temperature               is determined not only by the numberof times the relay is switched
    to be displayed after turning the power supply to the Temperature             but also by the service life of internal electronic components.
    Controller ON. Turn the power supply ON at least 30 minutes prior             Component service life is affected by the ambient temperatrue: the
    to starting control operations.                                               higher the temperature, the shorter the service life and, the lower
                                                                                  the temperature, the longer the service life. Therefore, the service
21.When extending the thermocouple lead wires, always use                         life can be extended by lowering the temperature of the
    compensating conductors suitable for the type of thermocouple.                Temperature Controller.
    Do not extend the lead wires on a platinum resistance
    thermometer. Use only low-resistance wire (5  max. per line) for          3. When two or more Temperature Controllers are mounted
    lead wires and make sure that the resistance is the same for all              horizontally close to each other or vertically next to one another,
    three wires.                                                                  the internal temperature will increase due to heat radiated by the
                                                                                  Temperature Controllers and the service life will decrease. In such
22.When drawing out the Temperature Controller from the case, do                  a case, use forced cooling by fansor other means of air ventilation
    not apply force that would deform or alter the Temperature                    to cool down the Temperature Controllers. When providing forced
    Controller.                                                                   cooling, however, be careful not to cool down the terminals
                                                                                  sections alone to avoid measurement errors.
23.When drawing out the Temperature Controller from the case to
    replace the Temperature Controller, check the status of the               Measurement Accuracy
    terminals. If corroded terminals are used, contact faults with the
    terminals may cause the temperature inside the Temperature                1. When extending or connecting the thermocouple lead wire, be
    Controller to increase, possibly resulting in fire. If the terminals are      sure to use compensating wires that match the thermocouple
    corroded, replace the rear case as well.                                      types.

24.When drawing out the Temperature Controller from the case, turn            2. When extending or connecting the lead wire of the platinum
    the power supply OFF first, and absolutely do not touch the                   resistance thermometer, be sure to use wires that have low
    terminals or electronic components or apply shock to them. When               resistance and keep the resistance of the three lead wires the
    inserting the Temperature Controller, do not allow the electronic             same.
    components to come into contact with the case.
                                                                              3. Mount the product so that it is horizontally level.
25.Static electricity may damage internal components. Always touch            4. If the measurement accuracy is low, check to see if input shift has
    grounded metal to discharge any static electricity before handling
    the Temperature Controller. When drawing out the Temperature                  been set correctly.
    Controller from the case, do not touch the electronic components
    or patterns on the board with your hand. Hold the Temperature             Operating Precautions
    Controller by the edge of the front panel when handling it.
                                                                              1. It takes approximately two seconds for the outputs to turn ON from
26.Do not use paint thinner or similar chemical to clean with. Use                after the power supply is turned ON. Due consideration must be
    standard grade alcohol.                                                       given to this time when incorporating Temperature Controllers in a
                                                                                  sequence circuit.
27.Use tools when separating parts for disposal. Contact with the
    sharp internal parts may cause injury.                                    2. When using self-tuning, turn ON power for the load (e.g., heater)
                                                                                  at the same time as or before supplying power to the Temperature
                                                                                  Controller. If power is turned ON for the Temperature Controller
                                                                                  before turning ON power for the load, self-tuning will not be
                                                                                  performed properly and optimum control will not be achieved.

                                                                              3. When starting operation after the Temperature Controller has
                                                                                  warmed up, turn OFF the power and then turn it ON again at the
                                                                                  same tim