Controllers Relay,HB 4 event AC volt

参数

产品属性属性值
产品种类:
Product Category:
Controllers
制造商:
Manufacturer:
Omron
Analog / Digital:Digital
类型:
Type:
Programmable Temperature Controller
Display Type:11-Segment, 4 Digit
工作电源电压:
Operating Supply Voltage:
240 VAC
Mounting:Panel
大小:
Size:
96 mm x 96 mm
商标:
Brand:
Omron Automation and Safety
Number of Inputs:4
Number of Outputs:1
输出类型:
Output Type:
Relay
系列:
Series:
E5_C-T
工厂包装数量:
Factory Pack Quantity:
1
单位重量:
Unit Weight:
8.818490 oz

E5AC-TRX4A5M-010器件文档内容

New Product

Digital Temperature Controller

E5@C/E5@C-T

Large White PV Display That's Easier to Read.

Easy to Use, from Model Selection to Setup and Operation.

New Plug-in Models That Are Convenient for Maintenance and Replacement

as replacing temperature controllers is possible without changing wiring.

New Models That Mount to DIN Track and Are Ideal for HMI/PLC Connections.

And Programmable Models to Support a Wider Range of Applications.

                                E5GC                       DIN 48 × 24 mm

                                                           page 2

                                E5CC                       DIN   48  ×  48  mm

                                                           page  16

                                E5CC-U

Digital Temperature Controller

E5@C                            E5EC                       DIN   48  ×  96  mm

                                                           page  34

Series

                                E5AC                       DIN   96  ×  96  mm

                                                           page  34

                                                           22.5 mm wide

                                E5DC                       Mounts to DIN

                                                           Track     page 50

Programmable                    E5CC-T                     DIN   48  ×  48  mm

Temperature Controller                                     page  64

(Digital Controller)

E5@C-T                          E5EC-T                     DIN   48  ×  96  mm

Series                                                     page  80

                                E5AC-T                     DIN   96  ×  96  mm

                                                           page  80

                                                                                1
   Digital Temperature Controller

   E5GC                                     (48 × 24 mm)

   Easy Operation and High Performance of

   the E5@C Series in a Compact 48 × 24-

   mm Body

   • A compact body of 48 × 24 × 90 mm (W × H × D) that is ideal for

   small equipment, laboratory instruments, and others.

   • White PV display with a height of 10.5 mm for high visibility even

   with the compact body.

   • Removable terminal block to simplify maintenance. Select from

   screw terminals or screwless clamp terminals for the wiring

   method.                                                                          48 × 24 mm               48 × 24 mm

   • High-speed sampling at 50 ms.                                                  Models with Screw     Models with Screwless

                                                                                    Terminal Blocks       Clamp Terminal Blocks

   • Easy connections to a PLC with programless communications.                     E5GC-@6                  E5GC-@C

   • Set up the Controller without wiring the power supply by

   connecting to the computer with a Communications Conversion                      Refer to your OMRON website for the most recent

   Cable (sold separately). Setup is easy with the CX-Thermo (sold                  information on applicable safety standards.

   separately).                                                                     Refer to Safety Precautions on page 104.

   Main  I/O Functions

            Sensor Input                                  E5GC

            Universal input

            • Thermocouple                                                          Dual displays: PV/SV     4-digit             displays

            • Pt

            • Analog current/voltage

                  Indication Accuracy                                               Control Output 1

                  • Thermocouple input:                                             • Relay output

                  ±0.3% of PV                                                       • Voltage output (for driving SSR)

                  • Pt input: ±0.2% of PV                                           • Linear current output

                  • Analog input: ±0.2% of  FS

                  Sampling Period                                                   Auxiliary Outputs

                  • 50 ms

                                                • PF (shift) Key                    • None

            Event Inputs                        • Temperature status display        •1

            • None                              • Simple programming                •2

            •1                                  • Independent heating and

            •2                                  cooling PID control

                                                • Changed parameter display

            Serial Communications               • Display brightness setting

            • None                              • Simple transfer output (only on

                                                models with liner current outputs)

            • RS-485                            • Work Bit Message

   This datasheet is provided as a guideline for selecting products.

   Be sure to refer to the following manuals for application precautions and other information required for operation before attempting

   to use the product.

   E5@C Digital Temperature Controllers User’s Manual (Cat. No. H174)

   E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)

2
                                                                                                                                            E5GC

Model Number Legend and Standard Models

Model Number Legend

E5GC-@@           @ @ @ M-@@@ (Example: E5GC-RX1A6M-015)
       −−         − − − − −−−
           A      BC     DE         F

               A         B          C         D                E          F

Model      Control       No. of     Power  Terminal            Input                                        Meaning

           outputs 1  auxiliary  supply       type             type       Options

           and 2      outputs    voltage

E5GC                                                                                                        48 × 24 mm

                                                                                     Control output 1                        Control output 2

           RX                                                                        Relay output                                     None

           QX                                                                        Voltage output                                   None

                                                                                     (for driving SSR)

      *1   CX                                                                        Linear current output                            None

                  *2  0                                                                                     None

                      1                                                                                     1

                      2                                                                                     2

                                 A                                                                          100 to 240 VAC

                                 D                                                                          24 VAC/DC

                                           6                                                            Screw terminals (with cover)

                                           C                                                            Screwless clamp terminals

                                                            M                                               Universal input

                                                                                     HB alarm and HS alarm  Communications                  Event inputs

                                                                          000        ---                                  ---                  ---

                                                                          015        ---                                  RS-485               ---

                                                                      *3  016        ---                                  ---                  1

                                                               *3, *4     023        1                                    ---                  ---

                                                                      *5  024        ---                                  ---                  2

*1  The control output can be used as a simple transfer output.

*2  Only option 000 can be selected if an auxiliary output is zero.

*3  Option 016 and 023 can be selected only if two auxiliary outputs are selected.

*4  Option with HB and HS alarms (023) cannot be selected if a linear current output is selected for the control output.

*5  Option 024 can be selected only if one auxiliary output is selected.

Heating and Cooling Control

●Using Heating and Cooling Control

A Control Output Assignment

An auxiliary output is used as the cooling control output.

B Control

If PID control is used, you can set PID control separately for heating and cooling.

This allows you to handle control systems with different heating and cooling response characteristics.

                                                                                                                                                          3
   E5GC

   Optional Products (Order Separately)

   USB-Serial Conversion Cable                                           Waterproof Packing

                Model                                                                  Model

          E58-CIFQ2                                                                    Y92S-P12

   Communications Conversion Cable                                       Note: This Waterproof Packing is provided with the Digital

                                                                         Temperature Controller.

                Model                                                    Draw-out Jig

          E58-CIFQ2-E

   Note: Always use this product together with the E58-CIFQ2.                          Model

   This Cable is used to connect to the bottom-panel Setup     Tool                    Y92F-55

   port.

   Current Transformers (CTs)                                            CX-Thermo Support Software

   Hole diameter                Model                                                  Model

   5.8 mm                      E54-CT1                                   EST2-2C-MV4

   12.0 mm                     E54-CT3                                   Note: CX-Thermo version 4.62 or higher is required for the E5GC.

   Mounting Adapter                                                      For the system requirements for the CX-Thermo, refer to

                                                                         information on the EST2-2C-MV4 on the OMRON website

                Model                                                    (www.ia.omron.com).

          Y92F-53 (2pcs)

   Note: This Mounting Adapter is provided with the Digital Temperature

   Controller.

4
                                                                                                                                          E5GC

Specifications

Ratings

Power supply voltage                   A in model number: 100 to 240 VAC, 50/60 Hz

                                       D in model number: 24 VAC, 50/60 Hz; 24 VDC

Operating voltage range                85% to 110% of rated supply voltage

Power consumption                      5.9 VA max. at 100 to 240 VAC, and 3.2 VA max. at 24 VAC or 1.8 W max. at 24 VDC

                                       Temperature input

                                       Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II

                                       Platinum resistance thermometer: Pt100 or JPt100

Sensor input                           Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C

                                       Analog input

                                       Current input: 4 to 20 mA or 0 to 20 mA

                                       Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

Input impedance                        Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB/

                                       THB.)

Control method                         ON/OFF control or 2-PID control (with auto-tuning)

           Relay output                SPST-NO, 250 VAC, 2 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5

Control                                V, 10 mA (reference value)

output     Voltage output              Output voltage 12 VDC ±20% (PNP), max. Load current: 21 mA, with short-circuit protection circuit

           (for driving SSR)

           Linear current output       4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: Approx. 10,000

Auxiliary  Number of outputs           1 or 2 (depends on model)

output     Output specifications       SPST-NO relay outputs, 250 VAC, 2 A (resistive load),

                                       Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value)

           Number of inputs            1 or 2 (depends on model)

Event      External contact input      Contact input ON: 1 kΩ max., OFF: 100 kΩ min.

input      specifications              Non-contact input ON: Residual voltage 1.5 V max.; OFF: Leakage current 0.1 mA max.

                                       Current flow: approx. 7 mA per contact

Setting method                         Digital setting using front panel keys

Indication method                      11-segment digital displays and individual indicators

                                       Character height: PV: 10.5 mm, SV: 5.0 mm

Multi SP                               Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or

                                       serial communications.*

Bank switching                         None

                                       Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burn-

                                       out (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self

Other functions                        tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change

                                       rate limit, logic operations, temperature status display, simple programming, moving average of input val-

                                       ue, display brightness setting, simple transfer output, and work bit message

Ambient operating temperature          −10 to 55°C (with no condensation or icing), For 3-year warranty: −10 to 50°C with standard mounting (with

                                       no condensation or icing)

Ambient operating humidity             25% to 85%

Storage temperature                    −25 to 65°C (with no condensation or icing)

Altitude                               2,000 m max.

Recommended fuse                       T2A, 250 VAC, time-lag, low-breaking capacity

Installation environment               Installation Category II, Pollution Degree 2 (IEC 61010-1 compliant)

* Only four set points are selectable  for event inputs.

                                                                                                                                                    5
   E5GC

   Input Ranges

   ●Thermocouple/Platinum Resistance Thermometer (Universal inputs)

   Sensor                                   Platinum resistance                                                                 Thermocouple                                                Infrared temperature

   type                                      thermometer                                                                                                                                           sensor

   Sensor

   specifica-                                Pt100            JPt100             K               J               T         E      L           U         N     R     S     B     W     PLII  10 to  60 to  115 to  140 to

                                                                                                                                                                                            70°C   120°C  165°C   260°C

                           tion

                                 2300                                                                                                                                           2300

                                 1800                                                                                                                                     1800

                                 1700                                                                                                                         1700  1700

                                 1600

   Temperature range (°C)        1500

                                 1400                                      1300                                                                         1300                          1300

                                 1300

                                 1200

                                 1100

                                 1000  850                                                 850                                    850

                                 900

                                 800

                                 700                                                                                       600

                                 600         500.0          500.0                   500.0

                                 500                                                                400.0  400      400.0               400      400.0

                                 400                                                                                                                                                                              260

                                 300                                                                                                                                                               120    165

                                 200                 100.0          100.0                                                                                                                   90

                                 100                                                                                                                                      100

                                 -100                0.0            0.0                                                                                       0     0           0     0     0      0      0       0

                                 -200                                               -20.0  -100     -20.0                         -100

                                       -200  -199.9         -199.9         -200                            -200  -199.9    -200         -200  -199.9    -200

   Set value                           0     1       2        3     4      5        6      7         8     9        10     11     12    13       14     15    16    17    18    19    20    21     22     23      24

                           Shaded settings are the default settings.

   The applicable standards for the input types are as follows:

   K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 60584-1                                             JPt100: JIS C 1604-1989, JIS C 1606-1989

   L: Fe-CuNi, DIN 43710-1985                                                                       Pt100: JIS C 1604-1997, IEC 60751

   U: Cu-CuNi, DIN 43710-1985                                                                       PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)

   W: W5Re/W26Re, ASTM E988-1990

   ●Analog input

                           Input type                         Current                                      Voltage

   Input specification                               4 to 20 mA     0 to 20 mA             1 to 5 V        0 to 5 V        0 to 10 V

                                                     Usable in the following ranges by scaling:

   Setting range                                     -1999 to 9999, -199.9 to 999.9,

                                                     -19.99 to 99.99 or -1.999 to 9.999

   Set value                                              25               26              27              28                 29

6
                                                                                                                                                 E5GC

Alarm Types

Each alarm can be independently set to one of the following 17 alarm types. The default is 2: Upper limit. (See note.)

Auxiliary outputs are allocated to alarms. ON delays and OFF delays (0 to 999 s) can also be specified.

Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not

    displayed.

    To use alarm 1, set the output assignment to alarm 1.

Set                                                Alarm output operation

value           Alarm type             When alarm value X           When alarm value X                             Description of function

                                                is positive              is negative

0          Alarm function OFF                                Output OFF                       No alarm

                                                                                              Set the upward deviation in the set point for the alarm upper

                                           ON      L     H                                    limit (H) and the lower deviation in the set point for the alarm

1          Upper- and lower-limit *1       OFF               PV     *2                        lower limit (L). The alarm is ON when the PV is outside this

                                                   SP

                                                                                              deviation range.

2                                                        X                    X               Set the upward deviation in the set point by setting the alarm

           Upper-limit                     ON                       ON                        value (X). The alarm is ON when the PV is higher than the

(default)                                  OFF     SP        PV     OFF       SP          PV  SP by the deviation or more.

                                                   X                                X         Set the downward deviation in the set point by setting the

3          Lower-limit                     ON                       ON                        alarm value (X). The alarm is ON when the PV is lower than

                                           OFF     SP        PV     OFF       SP          PV

                                                                                              the SP by the deviation or more.

                                                                                              Set the upward deviation in the set point for the alarm upper

           Upper- and lower-limit          ON      L     H                                    limit (H) and the lower deviation in the set point for the alarm

4          range *1                        OFF               PV     *3                        lower limit (L). The alarm is ON when the PV is inside this de-

                                                   SP

                                                                                              viation range.

           Upper- and lower-limit          ON      L     H                                    A standby sequence is added to the upper- and lower-limit

5          with standby sequence *1        OFF               PV     *4                        alarm (1). *6

                                       *5          SP

           Upper-limit with standby        ON            X          ON        X

6          sequence                        OFF               PV     OFF                   PV  A standby sequence is added to the upper-limit alarm (2). *6

                                                   SP                         SP

           Lower-limit with standby        ON      X                ON              X

7          sequence                        OFF               PV     OFF                   PV  A standby sequence is added to the lower-limit alarm (3). *6

                                                   SP                         SP

           Absolute-value upper-lim-       ON         X             ON           X            The alarm will turn ON if the process value is larger than the

8          it                              OFF               PV     OFF                   PV  alarm value (X) regardless of the set point.

                                                0                                      0

                                           ON         X             ON           X            The alarm will turn ON if the process value is smaller than the

9          Absolute-value lower-limit      OFF               PV     OFF                   PV  alarm value (X) regardless of the set point.

                                                0                                      0

           Absolute-value upper-lim-       ON         X             ON           X            A standby sequence is added to the absolute-value upper-

10         it with standby sequence        OFF               PV     OFF                   PV  limit alarm (8). *6

                                                0                                      0

           Absolute-value lower-limit      ON         X             ON           X            A standby sequence is added to the absolute-value lower-

11         with standby sequence           OFF               PV     OFF                   PV  limit alarm (9). *6

                                                0                                      0

12         LBA (alarm 1 type only)                               -                            *7

13         PV change rate alarm                                  -                            *8

           SP absolute-value               ON         X             ON           X            This alarm type turns ON the alarm when the set point (SP)

14         upper-limit alarm               OFF               SP     OFF                   SP  is higher than the alarm value (X).

                                                0                                      0

           SP absolute-value               ON         X             ON           X            This alarm type turns ON the alarm when the set point (SP)

15         lower-limit alarm               OFF               SP     OFF                   SP  is lower than the alarm value (X).

                                                0                                      0

                                       Standard Control             Standard  Control

                                           ON         X             ON           X

                                           OFF  0            MV     OFF                   MV

           MV absolute-value                                                           0      This alarm type turns ON the alarm when the manipulated

16         upper-limit alarm *9        Heating/Cooling              Heating/Cooling           variable (MV) is higher than the alarm value (X).

                                       Control (Heating MV)         Control (Heating MV)

                                           ON         X

                                           OFF  0            MV     Always ON

                                       Standard Control             Standard  Control

                                           ON         X             ON           X

                                           OFF  0            MV     OFF                0  MV

17         MV absolute-value           Heating/Cooling                                        This alarm type turns ON the alarm when the manipulated

           lower-limit alarm *9        Control (Cooling MV)         Heating/Cooling           variable (MV) is lower than the alarm value (X).

                                                                    Control (Cooling MV)

                                           ON         X

                                           OFF  0            MV     Always ON

                                                                                                                                                                7
   E5GC

   *1  With set values 1, 4, and 5, the upper- and lower-limit values can      *4  Set value: 5, Upper- and lower-limit with standby sequence

       be set independently for each alarm type, and are expressed as              For Upper- and Lower-Limit Alarm Described Above at *2

       “L” and “H.”                                                                •  In cases 1 and 2 above, the alarm is always OFF if the upper-

   *2  Set value: 1, Upper- and lower-limit alarm                                     and lower-limit hysteresis overlaps.

       Case 1             Case 2     Case 3 (Always OFF)                           •  In case 3, the alarm is always OFF.

                                                                    H<0, L<0   *5  Set value: 5, Upper- and lower-limit alarm with standby sequence

               L  H  SP   SP L    H     H               SP    L                    The alarm is always OFF if upper- and lower-limit hysteresis

               H<0, L>0   H>0, L<0                                  H<0, L>0       overlaps.

               |H| < |L|  |H| > |L|  H             L SP             |H| ≥ |L|  *6  Refer to the E5@C Digital Temperature Controllers User’s Manual

                                                                    H>0, L<0       (Cat. No. H174) for information on the operation of the standby

                                                        SP H     L  |H| ≤ |L|      sequence.

   *3  Set value: 4,      Upper- and lower-limit range                         *7  Refer to the E5@C Digital Temperature Controllers User’s Manual

       Case 1             Case 2     Case 3 (Always ON)                            (Cat. No. H174) for information on the LBA.

                                                                    H<0, L<0   *8  Refer to the E5@C Digital Temperature Controllers User’s Manual

       L          H  SP   SP L    H     H               SP    L                    (Cat. No. H174) for information on the PV change rate alarm.

       H<0, L>0           H>0, L<0                                  H<0, L>0   *9  When heating/cooling control is performed, the MV absolute-

       |H| < |L|          |H| > |L|  H             L SP             |H| ≥ |L|      value upper-limit alarm functions only for the heating operation

                                                                    H>0, L<0       and the MV absolute-value lower-limit alarm functions only for the

                                                        SP H     L  |H| ≤ |L|      cooling operation.

8
                                                                                                                                        E5GC

Characteristics

                                   Thermocouple:    (±0.3 % of indication value or ±1°C, whichever is greater) ±1 digit max.*1

Indication accuracy                Platinum resistance thermometer: (±0.2 % of indication value or ±0.8°C, whichever is greater) ±1 digit max.

(at the temperature of 23°C)       Analog input:    ±0.2% FS ±1 digit max.

                                   CT input:        ±5% FS ±1 digit max.

Simple transfer output accuracy    ±0.3% FS max.*2

Influence of temperature       *3  Thermocouple input (R, S, B, W, PL II): (±1% of indication value or ±10°C, whichever is greater) ±1 digit

                                   max.

                                   Other thermocouple input: (±1% of indication value or ±4°C, whichever is greater) ±1 digit max.      *4

Influence of voltage   *3          Platinum resistance thermometer: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max.

                                   Analog input: ±1% FS ±1 digit max.

                                   CT input: ±5% FS ±1 digit max.

Input sampling period              50 ms

Hysteresis                         Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                   Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

Proportional band (P)              Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                   Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I)                  0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5

Derivative time (D)                0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5

Proportional band (P) for cooling  Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                   Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I) for cooling      0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5

Derivative time (D) for cooling    0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5

Control period                     0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)

Manual reset value                 0.0% to 100.0% (in units of 0.1%)

Alarm setting range                −1,999 to 9,999 (decimal point position depends on input type)

Influence of signal source resis-  Thermocouple: 0.1°C/Ω max. (100 Ω max.), Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.)

tance

Insulation resistance              20 MΩ min. (at 500 VDC)

Dielectric strength                100 to 240 VAC: 3,000 VAC, 50/60 Hz for 1 min between terminals of different charge

                                   24 VAC/DC: 2,300 VAC, 50/60 Hz for 1 min between terminals of different charge

Vibration   Malfunction            10 to 55 Hz, 20 m/s2 for 10 min each in X, Y and Z directions

            Resistance             10 to 55 Hz, 20 m/s2 for 2 hr each in X, Y, and Z directions

Shock       Malfunction            100 m/s2, 3 times each in X, Y, and Z directions

            Resistance             300 m/s2, 3 times each in X, Y, and Z directions

Weight                             Controller: Approx. 80 g, Adapter: Approx. 4 g × 2

Degree of protection               Front panel: IP66, Rear case: IP20, Terminals: IP00

Memory protection                  Non-volatile memory (number of writes: 1,000,000 times)

Setup Tool                         CX-Thermo version 4.62 or higher

                                   E5GC side panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect a USB port on the com-

Setup Tool port                    puter. *6

                                   E5GC bottom panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion Cable

                                   are used together to connect a USB port on the computer.*6

Standards   Approved standards     UL 61010-1, Korean Radio Waves Act (Act 10564)

            Conformed standards    EN 61010-1 (IEC 61010-1): Pollution Degree 2 , overvoltage category II

                                   EMI:                                                      EN61326

                                   Radiated Interference Electromagnetic Field Strength:     EN55011            Group  1, class A

                                   Noise Terminal Voltage:                                   EN55011            Group  1, class A

                                   EMS:                                                      EN61326

EMC                                ESD Immunity:                                             EN61000-4-2

                                   Electromagnetic Field Immunity:                           EN61000-4-3

                                   Burst Noise Immunity:                                     EN61000-4-4

                                   Conducted Disturbance Immunity:                           EN61000-4-6

                                   Surge Immunity:                                           EN61000-4-5

                                   Voltage Dip/Interrupting Immunity:                        EN61000-4-11

*1  The indication accuracy of K thermocouples in the −200 to 1,300°C range, T and N thermocouples at a temperature of −100°C max., and U

    and L thermocouples at any temperature is ±2°C ±1 digit max. The indication accuracy of B thermocouples at a temperature of 400°C max. is

    not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800°C is ±3°C max.

    The indication accuracy of R and S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W

    thermocouples is (±0.3% of PV or ±3°C, whichever is greater) ±1 digit max.

    The indication accuracy of PLII thermocouples is (±0.3% of PV or ±2°C, whichever is greater) ±1 digit max.

*2  However, the precision between 0 and 4 mA for a 0 to 20 mA output is ±1% FS max.

*3  Ambient temperature: −10°C to 23°C to 55°C, Voltage range: −15% to 10% of rated voltage

*4  K thermocouple at −100°C max.: ±10°C max.

*5  The unit is determined by the setting of the Integral/Derivative Time Unit parameter.

*6  External serial communications (RS-485) and USB-Serial Conversion Cable communications can be used at the same time.

                                                                                                                                                9
E5GC

USB-Serial Conversion Cable                                                                                                 When Digital Temperature Controllers are connected, set

                                                                                                                            points and RUN/STOP commands can be sent from the Dig-

    Applicable OS           Windows XP/Vista/7/8                                    Component                               ital Temperature Controller that is set as the master to the

    Applicable software     CX-Thermo version 4.62 or higher                        Communica-                              Digital Temperature Controllers that are set as slaves.

                                                                                    tions                                   Slope and offsets can be set for the set point.

    Applicable models       E5@C-T Series, E5@C Series, and E5CB Series                                                     Number of connected Digital Temperature Controllers: 32

    USB interface standard  Conforms to USB Specification 2.0                                                               max. (including master)

    DTE speed               38,400 bps                                                                                      When Digital Temperature Controllers are connected, the pa-

                                                                                    Copying*                                rameters can be copied from the Digital Temperature Control-

    Connector               Computer: USB (Type A plug)                                                                     ler that is set as the master to the Digital Temperature

    specifications          Digital Temperature Controller: Special serial con-                                             Controllers that are set as slaves.

                            nector                                               MELSEC is a registered trademark of Mitsubishi Electric Corporation.

    Power supply            Bus power (Supplied from the USB host controller) *  KEYENCE is a registered trademark of Keyence Corporation.

    Power supply voltage    5 VDC                                                *                           Both the programless communications and the component communications

    Current consumption     450 mA max.                                                                      support the copying.

    Output voltage          4.7±0.2 VDC (Supplied from USB-Serial Conver-        Current Transformer (Order Separately)

                            sion Cable to the Digital Temperature Controller.)

    Output current          250 mA max. (Supplied from USB-Serial Conver-        Ratings

                            sion Cable to the Digital Temperature Controller.)

    Ambient operating       0 to 55°C (with no condensation or icing)               Dielectric strength                                  1,000 VAC for 1 min

    temperature                                                                     Vibration resistance                                 50 Hz, 98 m/s2

    Ambient operating       10% to 80%                                                                                                   E54-CT1: Approx. 11.5 g,

    humidity                                                                        Weight                                               E54-CT3: Approx. 50 g

    Storage temperature     −20 to 60°C (with no condensation or icing)                                                                  Armatures (2)

    Storage humidity        10% to 80%                                              Accessories (E54-CT3 only)                           Plugs (2)

    Altitude                2,000 m max.

    Weight                  Approx. 120 g                                        Heater Burnout Alarms and SSR Failure

Windows is a registered trademark of Microsoft Corporation in the                Alarms

United States and or other countries.

*   Use a high-power port for the USB port.                                         CT input (for heater current                         Models with detection for single-phase heat-

Note: A driver must be installed on the computer. Refer to the                      detection)                                           ers: One input

           Instruction Manual included with the Cable for the installation          Maximum heater current                               50 A AC

           procedure.                                                               Input current                                        ±5% FS ±1 digit max.

                                                                                    indication accuracy

Communications Specifications                                                       Heater burnout alarm                                 0.1 to 49.9 A (in units of 0.1 A)

                                                                                    setting range *1                                     Minimum detection ON time: 100 ms *3

    Transmission line connection    RS-485: Multidrop                               SSR failure alarm setting                            0.1 to 49.9 A (in units of 0.1 A)

    method                                                                          range *2                                             Minimum detection OFF time: 100 ms *4

    Communications                  RS-485 (two-wire, half duplex)               *1                          For heater burnout alarms, the heater current will be measured when the

    Synchronization method          Start-stop synchronization                                               control output is ON, and the output will turn ON if the heater current is

    Protocol                        CompoWay/F, or Modbus                                                    lower than the set value (i.e., heater burnout detection current value).

                                                                                 *2                          For SSR failure alarms, the heater current will be measured when the

    Baud rate*                      9,600, 19,200, 38,400, or 57,600 bps                                     control output is OFF, and the output will turn ON if the heater current is

    Transmission code               ASCII                                                                    higher than the set value (i.e., SSR failure detection current value).

                                                                                 *3                          The value is 30 ms for a control period of 0.1 s or 0.2 s.

    Data bit length *               7 or 8 bits                                  *4                          The value is 35 ms for a control period of 0.1 s or 0.2 s.

    Stop bit length *               1 or 2 bits                                  Electrical Life Expectancy Curve for

                                    Vertical parity (none, even, odd)

    Error detection                 Block check character (BCC)                  Control Output Relay (Reference Values)

                                    with CompoWay/F or

                                    CRC-16 with Modbus                              Life (× 104 operations)  500

    Flow control                    None                                                                     300

    Interface                       RS-485                                                                   200

    Retry function                  None                                                                     100

    Communications buffer           217 bytes                                                                                            E5GC

    Communications response         0 to 99 ms                                                               50                          250 VAC, 30 VDC

                                                                                                                                         (resistive load)

    wait time                       Default: 20 ms                                                           30                          cosφ = 1

* The baud rate, data bit length, stop bit length, and vertical parity can                                   20

    be individually set using the Communications Setting Level.                                              10

Communications Functions

                     You can use the memory in the PLC to read and write E5@C                                5

                     parameters, start and stop operation, etc.                                              3

                     The E5@C automatically performs communications with                                     2

                     PLCs. No communications programming is required.

                     Number of connected Digital Temperature Controllers: 32                                 1

    Programless      max. (Up to 16 for the FX Series)                                                            0.1  0.2  0.3  0.5  1  2           3  5        10

    communica-       Applicable PLCs: OMRON PLCs                                                                                         Switching current (A)

    tions                   CS Series, CJ Series, or CP Series

                       Mitsubishi Electric PLCs

                            MELSEC Q Series, L Series, or FX Series (compati-

                            ble with the FX2 or FX3 (excluding the FX1S))

                       KEYENCE PLCs

                            KEYENCE KV Series

10
                                                                                                                                                                                E5GC

External Connections

E5GC

Control Outputs

Relay output                                                                                                    E5GC-@ @ @ @ @ M - @ @ @

250 VAC, 2 A                                                                                                            (1)    (2)(3)(4)(5)   (6)

(resistive load)                                                                                                                      ↑

Voltage output (for driving SSR)                                                                                               Terminal type

12 VDC, 21 mA                              Auxiliary outputs 1, 2

Linear current output                                                             The E5GC is set for a K-type thermocouple (input type = 5) by

0 to 20 mA DC                           Relay outputs                             default. An input error (s.err) wil occur if the input type setting

4 to 20 mA DC                           250 VAC, 2 A                              does not agree with the temperature sensor. Check the input type.

Load: 500 Ω max.                        (resistive load)

                                  (6) Options                                                                                                          (5) Sensor

                                  015                              016                   023                    024                                        (Temperature/

                                  Communications                   Event input 1         CT input               Event inputs 1 and 2                       Analog) Input

                                  (RS-485)                                                                      EV2  −         +                                  −         +

                                        RS-485                           −     +                    CT                  +

                                  B(+)           A(−)              EV1                                          EV1

                                                                                                                                                       TC  10     11        12

                                        7     8  9                       7     8  9              7      8  9         7  8      9

                                                                                                                                                              A         B   B

                                                                                                                                                       Pt  10     11        12

                                  (3) Input Power Supply                                                                                                   +     mA      −

                                  100 to 240 VAC       24 VAC/DC

                                        1     2                                                         7  8    9  10   11     12                      I   10     11        12

                                                                   1        2

                                                                                                                                                                  −      V  +

                                                                                                        1  2    3    4  5      6                       V

                                                       (no polarity)                                                                                       10     11        12

                                                                                                                               (2) Auxiliary  Outputs

                                  (1) Control Outputs                                                                             Auxiliary   Auxiliary outputs      1,  2

                                                                                                                                  output 1             Auxiliary

                                  RX                   QX                                CX                                                            output 2

                                  Relay output         Voltage output (for driving SSR)  Linear current output                                     9

                                           R                          Q                          C

                                                                   +     −                   +      −

                                                                                                                                   5     6                    5      6

                                        3     4                    3        4                3      4                          Auxiliary               Auxiliary

                                                                                                                               output 1                output 1

Note: 1.   The application of the terminals depends on the model.

       2.  Do not wire the terminals that are shown with a gray background.

       3.  When complying with EMC standards, the cable that connects the                                          sensor      must be 30 m or less.

           If the cable length exceeds 30 m, compliance with EMC standards                                           will not  be possible.

       4.  Connect M3 crimped terminals.

Isolation/Insulation Block Diagrams

                                           Sensor input and CT input

                                           Communications and event inputs

       Power      Voltage output (for driving SSR) and linear current                    output

       supply

                                                 Relay output

                                              Auxiliary outputs 1 and 2

                  : Reinforced insulation

                  : Functional isolation

Note:  Auxiliary  outputs 1 to 2 are not insulated.

                                                                                                                                                                                11
E5GC

Wiring Methods

    E5GC-@6                                                                                         E5GC-@C

    Controllers with Screw Terminal Blocks (M3 Screws)                                              Controllers with Screwless Clamp Terminal Blocks

                                           Controllers with Screw Terminal Blocks                                                    Controllers with Screwless Clamp Terminals Blocks

                                           • Terminal type: Forked or round crimped terminals                                        • Wire stripping length: 8 to 12 mm

                                           • Tightening torque for all terminals: 0.43 to 0.58 N·m                                   • Ferrules: 8 to 12 mm

                                                                                                                                                                 0.8 to 1.4 mm

                                                   5.8 mm max.

                                                                                                                                     8 to 12 mm                                 8 to 12 mm

                                                   5.8 mm max.

Wires: AWG24 to AWG18 (equal to a cross-sectional area of 0.205 to 0.823 mm2) braided or solid wires

Nomenclature

E5GC                                               Front panel

                                                                                                                                     Left Side View of the E5GC

                                                                                                    No. 1 display                                                    Left-panel

                                                                                                                                                                     Setup Tool

             Temperature unit                                                                       PV or specified parameter                                        port

                                                                                                    No.2 display

                                                                                                    SP or specified parameter value  Bottom View of E5GC

             Operation indicators

      Press O Key once to go to Adjustment Level.

      Press O Key for at least 3 seconds                                           Use the U D Keys to set the parameter.

      to go to the Initial Setting Level.                                                                                                                 Bottom-panel Setup

                                                                                                                                                          Tool port

                                           Use the M Key to change                 Use S Key to change the

                                           to another parameter.                   digit (default setting).

12
                                                                                                                                                         E5GC

Dimensions                                                                                                                                               (Unit: mm)

Controllers

E5GC-@6                                                                             Waterproof Packing (Accessory)

Controllers with Screw                                                              Mounting Adapter (Accessory)

Terminal Blocks                          63.6             4                         90                                   Terminal Cover (Accessory)

                                         48                                                                                     44.8

                                                             1

                         24                               40.8                                            22                                  22

                 • Use two Mounting Adapters, either on the top and bottom or on the right and left.

                 • Setup Tool ports are provided as standard feature. Use these ports to connect a computer to the Digital Temperature Controller. The E58-

                    CIFQ2 USB-Serial Conversion Cable is required to connect to the port on the side panel. The E58-CIFQ2 USB-Serial Conversion Cable

                    and E58-CIFQ2-E Communications Conversion Cable are required to connect to the port on the bottom panel. (You cannot leave either

                    port connected constantly during operation.)

                    Mounted Separately                  Horizontally Group Mounted

                                                                L1

                                                                                22.2+00.3             To mount the Temperature Controller so that it is waterproof,

                 40 min                                                                               insert the Waterproof Packing onto the Temperature Controller.

                            45+0.60                       L1=(48×n-2.5)   +1.0                        Group mounting does not allow waterproofing.

                                                                          +0

                                         22.2+00.3  n: Number of mounted Controllers (2 ≤ n ≤ 6)

                 •  To install the Temperature Controller, insert it into a square hole in a panel with a thickness of 1 to 8 mm, and then insert the enclosed

                    adapter so that it locks into the grooves on the top and bottom or on the left and right of the rear case.

                 •  Tighten the two mounting screws on the top and bottom or on the right and left of the Mounting Adapters alternately little by little to main-

                    tain a balance, and tighten them to a torque of between 0.29 and 0.39 N·m.

                 •  When two or more Temperature Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable

                    operating temperature range given below.

                    Horizontal group mounting: −10 to 55°C

                 •  Use Temperature Controllers with Screwless Clamp Terminal Blocks for vertical group mounting.

E5GC-@C                                                                                           Waterproof Packing (Accessory)

Controllers with Screwless                                                                        Mounting Adapter (Accessory)

Clamp Terminal Blocks                               63.6            4                             93

                                                    48                                                                                  44.8

                                                                       1

                                     24                         40.8                                                 22                              22

                 •  Use two Mounting Adapters, either on the top and bottom or on the right and left.

                 •  Setup Tool ports are provided as standard feature. Use these ports to connect a computer to the Digital Temperature Controller. The E58-

                    CIFQ2 USB-Serial Conversion Cable is required to connect to the port on the side panel. The E58-CIFQ2 USB-Serial Conversion Cable

                    and E58-CIFQ2-E Communications Conversion Cable are required to connect to the port on the bottom panel. (You cannot leave either

                    port connected constantly during operation.)

                    Mounted Separately              Horizontally Group Mounted                        Vertically Group Mounted

                                                                L1                                    45  +0.6

                                                                                                          +0

                                                                                22.2+00.3                                         To mount the Temperature Controller so

                 40 min                                                                                                           that it is waterproof, insert the Waterproof

                            45+0.60                       L1=(48×n-2.5)   +1.0                                                    Packing onto the Temperature Controller.

                                                                          +0

                                                    n: Number of mounted Controllers (2 ≤ n ≤ 6)                     L2           Group mounting does not allow waterproof-

                                         22.2+00.3                                                                                ing.

                                                                                                      L2=(24×n-1.5)  +1.0

                                                                                                                     +0

                 •  To install the Temperature Controller, insert it into a square hole in a panel with a thickness of 1 to 8 mm, and then insert the enclosed

                    adapter so that it locks into the grooves on the top and bottom or on the left and right of the rear case.

                 •  Tighten the two mounting screws on the top and bottom or on the right and left of the Mounting Adapters alternately little by little to main-

                    tain a balance, and tighten them to a torque of between 0.29 and 0.39 N·m.

                 •  When two or more Temperature Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable

                    operating temperature range given below.

                    Horizontal group mounting: −10 to 55°C

                    Vertical group mounting of two Controllers: −10 to 45°C

                    Vertical group mounting of three or more Controllers: −10 to 40°C

                 •  If you use vertical group mounting, you cannot draw out the interior body of the Controller.

                                                                                                                                                                                13
E5GC

Accessories (Order Separately)

● USB-Serial Conversion Cable                                                                                                           (2110)

E58-CIFQ2                                                    250                                                                                      263                                    1510

                                                                                             LED (RD)

                                              USB connector

                                              (type A plug)                                                                                                                                             Serial connector

                                                                                                                                        LED (PWR)

                                                                                                                                        LED (SD)

● Conversion Cable

E58-CIFQ2-E

            Conversion Cable                        Connecting to               the     E58-CIFQ2 USB-Serial Conversion Cable

                                                                                                                                        (2110)

                          (1510)                                       250                                                                            263                                       1510

Note: Always use this product together        with the  E58-CIFQ2.                           E58-CIFQ2  (Order separately)                                                              Conversion Cable

● Current Transformers

E54-CT1                                                                                                 Thru-current (Io) vs. Output Voltage (Eo) (Reference                                              Values)

                                                    21                          2.8

                                                    15       5.8 dia.                                   E54-CT1

                                                                                                        Maximum continuous heater current:                                          50 A (50/60 Hz)

                                                                                        7.5             Number of windings:                                                         400±2

                                                                                                        Winding resistance:                                                         18±2 Ω

                                  25      3

                                                                                                        Output voltage (Eo) V (r.m.s.)  100V      Frequency: 50 Hz

                                                                       10.5

                                                                                                                                        10                          ∞                   Distortion

                                                    40                                                                                                1kΩ                               factor

                                                             Two, 3.5 dia.                                                              1                                               10%

                                                                                                                                                                                        3%

                                          10                                                                                                                                        1%

                                                                                                                                        100mV

                                                    30

                                                                                                                                        10                                100Ω

E54-CT3                                                                      2.36 dia.

                                              30                                                                                        1                                 RL=10Ω

                                                             12 dia.

                                                                                        9

                                                                                                                                        100μV

                                  40 × 40                                                                                               10

                                                                                                                                               1  10  100mA            1        10      100  1,000A

                                                                                                                                                                          Thru-current (Io) A (r.m.s.)

                                                                                                        Thru-current (Io) vs. Output Voltage (Eo) (Reference Values)

                                                        Two , M3 holes (depth:     4)                   E54-CT3

                                      15                                                                Maximum continuous heater current: 120 A (50/60 Hz) (Maximum

                                                                                                        continuous heater current for an OMRON Digital Temperature Con-

                                                                                                        troller is 50 A.)

                                              30                                                        Number of windings: 400±2

E54-CT3 Accessories                                                                                     Winding resistance: 8±0.8 Ω

                                                                                                        Output voltage (Eo) V (r.m.s.)  100V      Frequency: 50 Hz

    • Armature                            Connection    Example                                                                                                     ∞                        Distortion

                                                                                                                                        10            1kΩ                                    factor

                                                             Armature                                                                                                                        10%

    Approx. 3 dia.                            Plug                                                                                                    500Ω                                   3%

                                                                                                                                        1                                                   1%

                                                                             Lead

                                                                                                                                        100mV

                                                                                                                                                                                100Ω

                          18                                                                                                            10                                50Ω

    • Plug                                                                                                                                                                RL=10Ω

                                                                                                                                        1

    Approx. 6 dia.                                                                                                                      100μV

                    (22)                                                                                                                10

                                                                                                                                               1  10  100mA            1        10      100  1,000A

                                                                                                                                                                          Thru-current (Io) A (r.m.s.)

14
                                                                                                                                                         E5GC

●  Mounting Adapter

Y92F-53 (Two provided.)

One pair is provided with the Termperature

Controller. Order this Adapter separately if it                                  34.7

becomes lost or damaged.

                                                                       12

                                                                 11.8  9.4

● Waterproof Packing

Y92S-P12

                                                 The Waterproof Packing is provided with the Temperature Controller.

                                                 Order the Waterproof Packing separately if it becomes lost or damaged.

                                                 The Waterproof Packing can be used to achieve an IP66 degree of protection.

                                                 (Deterioration, shrinking, or hardening of the waterproof packing may occur depending on the operating

                                                 environment. Therefore, periodic replacement is recommended to ensure the level of waterproofing

                                                 specified in IP66. The time for periodic replacement depends on the operating environment.

                                                 Be sure to confirm this point at your site. Consider three years a rough standard.)

                                                 The Waterproof Packing does not need to be attached if a waterproof structure is not required.

● Draw-out Jig

Y92F-55

Use this Draw-out Jig to remove the interior

body of the Digital Temperature Controller

from the case to perform maintenance

without removing the terminal wiring.

                                                           32.9

                                                 15        30.5  1.4

                                                                           27.4

                                                     28.7              22

                                                                 20

                                                                                 23

                                                                                                                                                         15
    Digital Temperature Controller

    E5CC/E5CC-U                                                           (48 × 48 mm)

Large White PV Display That’s Easier to Read.

Easy to Use, from Model Selection to

Setup and Operation.

A Complete Range of I/O Capacities,

Functions, and Performance.

Handles More Applications.

    • The white PV display with a height of 15.2 mm improves visibility.

    • High-speed sampling at 50 ms.                                             48 × 48 mm                        48 × 48 mm

    • Models are available with up to 3 auxiliary outputs, up to 4 event        E5CC                              E5CC-U

    inputs, a transfer output, and a remote SP input to cover a wide      Refer to your OMRON website for the most recent information on

    range of applications.                                                applicable safety standards.

    • E5CC: Short body with depth of only 60 mm.

    • Set up the Controller without wiring the power supply by                              Refer to Safety Precautions on page 104.

    connecting to the computer with a Communications Conversion

    Cable (sold separately). Setup is easy with the CX-Thermo (sold

    separately).

    • Easy connections to a PLC with programless communications. Use component communications to link

    Temperature Controllers to each other.

Main I/O Functions

    Sensor Input                                  E5CC/E5CC-U

    Universal input

    • Thermocouple                                                              Dual displays: PV/SV              4-digit displays

    • Pt

    • Analog current/voltage

          Indication Accuracy                                                   Control Output 1

          • Thermocouple input:                                                 • Relay output

          ±0.3% of PV                                                           • Voltage output (for driving     SSR)

          • Pt input: ±0.2% of PV                                               • Linear current output

          • Analog input:

          ±0.2% of FS                                                           Control Output 2

                                                                                                  

          Sampling Period                                                       • None                  • None

                                                                                • Voltage output

          • 50 ms                                                               (for driving SSR)

    Event Inputs                                                                Auxiliary Outputs

                              • PF (shift) Key                                      

    • None               • None             • Temperature status display        •3                      • None

    •2                                      • Simple programming                                        •1

    •4                                      • Independent heating and                                   •2

                                            cooling PID control                 Transfer Output

    Remote SP Input                         • Changed parameter display

                              • Display brightness setting                          

    • None               • None                                                 • None                  • None

    •1                                                                          •1

    Serial Communications

                   

    • None               • None

    • RS-485

    This datasheet is provided as a guideline for selecting products.

    Be sure to refer to the following manuals for application precautions and other information required for operation before attempting

    to use the product.

    E5@C Digital Temperature Controllers User’s Manual (Cat. No. H174)

    E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)

16
                                                                                                                                             E5CC/E5CC-U

Model Number Legend and Standard Models

Model Number Legend

●Models with Screw Terminals

E5CC-@@         3  @  5  M -@@@ (Example: E5CC-RX3A5M-000)
       −−       − − − − −−−
            A   BC    DE         F

                   A                B          C                 D         E             F

Model           Control outputs     No. of  Power             Terminal  Input                                                       Meaning

                1 and 2          auxiliary  supply               type      type          Options

                                 outputs    voltage

E5CC                                                                                                                                48 × 48 mm

                                                                                                            Control output 1                    Control output 2

            RX                                                                                                  Relay output                         None

            QX                                                                                                  Voltage output                       None

                                                                                                            (for driving SSR)

     *1 *3  CX                                                                                         Linear current output *2                      None

            QQ                                                                                                  Voltage output                  Voltage output

                                                                                                            (for driving SSR)                   (for driving SSR)

            CQ                                                                                         Linear current output *2                 Voltage output

                                                                                                                                                (for driving SSR)

                                 3                                                                              3 (one common)

                                            A                                                                   100 to 240 VAC

                                            D                                                                                       24 VAC/DC

                                                              5                                                 Screw terminals (with cover)

                                                                        M                                       Universal input

                                                                                                  HB alarm and  Communications      Event       Remote     Transfer

                                                                                                  HS alarm                          inputs      SP Input   output

                                                                                         000      ---           ---                 ---         ---        ---

                                                                                     *1  001      1             ---                          2  ---        ---

                                                                                                  2

                                                                                     *1  003      (for 3-phase  RS-485              ---         ---        ---

                                                                                                  heaters)

                                                                                     *3  004      ---           RS-485                       2  ---        ---

                                                                                         005      ---           ---                          4  ---        ---

                                                                                         006      ---           ---                          2             Provided.

                                                                                         007      ---           ---                          2  Provided.  ---

*1.  Options with HB and HS alarms (001 and 003) cannot be selected if a linear current output is selected for the control output.

*2.  The control output cannot be used as a transfer output.

*3.  Option 004 can be selected only when "CX" is selected for the control outputs.

Heating and Cooling Control

● Using Heating and Cooling Control

A Control Output Assignment

If there is no control output 2, an auxiliary output is used as the cooling control output.

If there is a control output 2, the two control outputs are used for heating and cooling.

(It does not matter which output is used for heating and which output is used for cooling.)

B Control

If PID control is used, you can set PID control separately for heating and cooling.

This allows you to handle control systems with different heating and cooling response characteristics.

                                                                                                                                                                      17
E5CC/E5CC-U

Model Number Legend

●Plug-in Models

E5CC-@@                @ @ U M -000 (Example: E5CC-RW0AUM-000)

            A          B    C  D     E   F

                    A        B           C          D         E            F

    Model   Control          No. of   Power      Terminal  Input                                                       Meaning

            outputs       auxiliary   supply        type      type  Options

            1 and 2       outputs     voltage

    E5CC                                                                                                          48 × 48 mm

                                                                                     Control output 1                              Control output  2

            RW                                                                       Relay output (SPDT)                             None

            QX                                                                       Voltage output (for driving SSR)                None

            CX                                                                       Linear current output*                          None

                          0                                                                                            None

                          1                                                                                            1

                          2                                                                                  2 (one common)

                                     A                                                                            100 to 240 VAC

                                     D                                                                                 24 VAC/DC

                                                 U                                                                Plug-in model

                                                           M                                                      Universal input

                                                                                     HB alarm and HS  Communi-         Event inputs  Remote SP     Transfer  out-

                                                                                     alarm            cations                        Input            put

                                                                           000       ---                     ---             ---     ---              ---

* The control output can be used as a simple transfer output for the Digital Temperature Controllers manufactured in May 2014 or later.

List of Models

                                                                    Options                                  Model                        Model

    Control output     No. of auxiliary                                                               Power supply voltage           Power supply voltage

                             outputs        HB alarm and      No. of event      Communications

                                                 HS alarm          inputs                             100 to 240 VAC                 24 VAC/DC

                       ---                                                                      E5CC-RW0AUM-000                    E5CC-RW0DUM-000

    Relay output       1                    ---               ---               ---             E5CC-RW1AUM-000                    E5CC-RW1DUM-000

                       2                                                                        E5CC-RW2AUM-000                    E5CC-RW2DUM-000

                       ---                                                                      E5CC-QX0AUM-000                    E5CC-QX0DUM-000

    Voltage output     1                    ---               ---               ---             E5CC-QX1AUM-000                    E5CC-QX1DUM-000

    (for driving SSR)

                       2                                                                        E5CC-QX2AUM-000                    E5CC-QX2DUM-000

                       ---                                                                      E5CC-CX0AUM-000                    E5CC-CX0DUM-000

    Linear current     1                    ---               ---               ---             E5CC-CX1AUM-000                    E5CC-CX1DUM-000

    output

                       2                                                                        E5CC-CX2AUM-000                    E5CC-CX2DUM-000

Heating and Cooling Control

●Using Heating and Cooling Control

A Control Output Assignment

An auxiliary output is used as the cooling control output.

B Control

If PID control is used, you can set PID control separately for heating and cooling.

This allows you to handle control systems with different heating and cooling response characteristics.

18
                                                                                                         E5CC/E5CC-U

Optional Products (Order Separately)

USB-Serial Conversion Cable                                           Front Covers

             Model                                                    Type                        Model

         E58-CIFQ2                                                    Hard Front Cover         Y92A-48H

                                                                      Soft Front Cover         Y92A-48D

Terminal Covers (for E5CC)

             Model                                                    CX-Thermo Support Software

         E53-COV17                                                                      Model

         E53-COV23 (3pcs)                                             EST2-2C-MV4

Note: The Terminal Covers E53-COV23 are provided only with E5CC       Note: CX-Thermo version 4.5 or higher is required for the E5CC.

Controllers. The E53-COV10 cannot be used.                            CX-Thermo version 4.61 or higher is required for the E5CC-U.

Refer to page 28 for the mounted dimensions.                          For the system requirements for the CX-Thermo, refer to

Waterproof Packing                                                    information on the EST2-2C-MV4 on the OMRON website

                                                                      (www.ia.omron.com).

             Model

         Y92S-P8

Note: The Waterproof Packing is provided only with E5CC

Controllers.

The E5CC-U cannot be waterproofed even if the Waterproof

Packing is attached.

Current Transformers (CTs)

Hole diameter                Model

5.8 mm                      E54-CT1

12.0 mm                     E54-CT3

Adapter

             Model

         Y92F-45

Note: Use this Adapter when the panel has already been prepared for

an E5B@ Controller.

Waterproof Cover

             Model

         Y92A-48N

Mounting Adapter

             Model

         Y92F-49

Note: This Mounting Adapter is provided with the Digital Temperature

Controller.

DIN Track Mounting Adapter

             Model

         Y92F-52

Sockets (for E5CC-U)

                  Type                          Model

Front-connecting Socket                         P2CF-11

Front-connecting Socket with Finger Protection  P2CF-11-E

Back-connecting Socket                          P3GA-11

Terminal Cover for Back-connecting socket       Y92A-48G

with Finger Protection

                                                                                                                                       19
E5CC/E5CC-U

Specifications

Ratings

    Power supply voltage                   A in model number: 100 to 240 VAC, 50/60 Hz

                                           D in model number: 24 VAC, 50/60 Hz; 24 VDC

    Operating voltage range                85% to 110% of rated supply voltage

                                           Models with option selection of 000: 5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at 24 VAC or

    Power consumption                                                              1.6 W max. at 24 VDC

                                           All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC

                                           Temperature input

                                           Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II

                                           Platinum resistance thermometer: Pt100 or JPt100

    Sensor input                           Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C

                                           Analog input

                                           Current input:     4 to 20 mA or 0 to 20 mA

                                           Voltage input:     1 to 5 V, 0 to 5 V, 0 to 10 V,or 0 to 50 mV (The 0 to 50 mV range applies to the

                                                              E5CC-U only for those manufactured in May 2014 or later.)

    Input impedance                        Current input: 150 Ω max., Voltage input: 1 MΩ min.

                                           (Use a 1:1 connection when connecting the ES2-HB/THB.)

    Control method                         ON/OFF control or 2-PID control (with auto-tuning)

                                           E5CC:    SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum ap-

                  Relay output                      plicable load: 5 V, 10 mA (reference value)

    Control                                E5CC-U:  SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applica-

    output                                          ble load: 5 V, 10 mA (reference value)

                  Voltage output           Output voltage: 12 VDC ±20% (PNP), max. load current: 21 mA, with short-circuit protection circuit

                  (for driving SSR)

                  Linear current output    4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000

                  Number of outputs        E5CC: 3

    Auxiliary                              E5CC-U: 1 or 2 (depends on model)

    output                                 SPST-NO relay outputs, 250 VAC, Models with 1 or 2 outputs: 3 A (resistive load), or Models with 3

                  Output specifications    outputs: 2 A (resistive load), Electrical life: 100,000 operations, Minimum applicable load: 10 mA at

                                           5 V (reference value)

                  Number of inputs         2 or 4 (depends on model)

    Event         External contact input   Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.

    input*        specifications           Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.

                                           Current flow: Approx. 7 mA per contact

    Transfer      Number of outputs        1 (only on models with a transfer output)

    output*       Output specifications    Current output: 4 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000

                                           Linear voltage output: 1 to 5 VDC, load: 1 kΩ min., resolution: Approx. 10,000

    Setting method                         Digital setting using front panel keys

    Remote SP input*                       Current input: 4 to 20 mA DC or 0 to 20 mA DC (input impedance: 150 Ω max.)

                                           Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V (input impedance: 1 MΩ min.)

    Indication method                      11-segment digital display and individual indicators

                                           Character height: PV: 15.2 mm, SV: 7.1 mm

    Multi SP*                              Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations,

                                           or serial communications.

    Bank switching                         None

                                           Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater

                                           burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital

    Other functions                        filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root,

                                           MV change rate limit, logic operations, temperature status display, simple programming, moving

                                           average of input value, and display brightness setting

    Ambient operating temperature          −10 to 55°C (with no condensation or icing), For 3-year warranty: −10 to 50°C with standard mounting

                                           (with no condensation or icing)

    Ambient operating humidity             25% to 85%

    Storage temperature                    -25 to 65°C (with no condensation or icing)

    Altitude                               2,000 m max.

    Recommended fuse                       T2A, 250 VAC, time-lag, low-breaking capacity

    Installation environment               Installation Category II, Pollution Degree 2 (IEC 61010-1 compliant)

* There are no optional functions for the  E5CC-U. Refer to Model Number Legend and List of Models on page 18.

20
                                                                                                                                                                                       E5CC/E5CC-U

Input Ranges

●Thermocouple/Platinum Resistance Thermometer (Universal inputs)

Sensor                                   Platinum resistance                                                                 Thermocouple                                                    Infrared temperature

                        type              thermometer                                                                                                                                               sensor

Sensor

specifica-                                Pt100          JPt100                K               J               T          E     L           U              N   R     S     B     W     PLII  10 to  60 to  115 to  140 to

                                                                                                                                                                                             70°C   120°C  165°C   260°C

                        tion

                              2300                                                                                                                                               2300

                              1800                                                                                                                                         1800

                              1700                                                                                                                             1700  1700

                              1600

Temperature range (°C)        1500

                              1400                                       1300                                                                          1300                            1300

                              1300

                              1200

                              1100

                              1000  850                                                  850                                    850

                              900

                              800

                              700                                                                                         600

                              600         500.0          500.0                    500.0

                              500                                                                 400.0  400      400.0               400      400.0

                              400                                                                                                                                                                                  260

                              300                                                                                                                                                                   120    165

                              200                 100.0         100.0                                                                                                                        90

                              100                                                                                                                                          100

                               0                  0.0           0.0                                                                                            0     0           0     0     0      0      0       0

                              -100                                                -20.0  -100     -20.0                         -100

                              -200  -200  -199.9         199.9           -200                            -200     -199.9  -200        -200     -199.9  -200

Set                     value       0     1       2      3        4      5        6      7        8      9         10     11    12    13       14      15      16    17    18    19    20    21     22     23      24

                        Shaded settings are the default settings.

The applicable standards for the input types are as follows:

K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 60584-1                                              JPt100: JIS C 1604-1989, JIS C 1606-1989

L: Fe-CuNi, DIN 43710-1985                                                                        Pt100: JIS C 1604-1997, IEC 60751

U: Cu-CuNi, DIN 43710-1985                                                                        PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)

W: W5Re/W26Re, ASTM E988-1990

●Analog input

Input type                                               Current                                                   Voltage

Input                                     4 to 20 mA            0 to 20 mA           1 to 5 V            0 to 5 V            0 to 10 V      0  to      50 mV*

specification

                                          Usable in the following ranges by scaling:

Setting range                             -1999 to 9999, -199.9 to 999.9,

                                          -19.99 to 99.99 or -1.999 to 9.999

Set value                                         25                 26                  27                    28               29                     30

* The range applies to the E5CC-U only for those manufactured in May 2014 or later.

                                                                                                                                                                                                                           21
E5CC/E5CC-U

Alarm Types

Each alarm can be independently set to one of the following 19 alarm types. The default is 2: Upper limit. (see note.)

Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.

Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed.

        To use alarm 1, set the output assignment to alarm 1.

    Set                                                Alarm output operation

    value          Alarm type              When alarm value X            When alarm value X                              Description of function

                                                    is positive               is negative

    0          Alarm function OFF                                Output OFF                         No alarm

                                                                                                    Set the upward deviation in the set point for the alarm upper

                                               ON      L     H                                      limit (H) and the lower deviation in the set point for the alarm

    1          Upper- and lower-limit *1       OFF               PV      *2                         lower limit (L). The alarm is ON when the PV is outside this

                                                       SP

                                                                                                    deviation range.

    2                                                        X                     X                Set the upward deviation in the set point by setting the alarm

               Upper-limit                     ON                        ON                         value (X). The alarm is ON when the PV is higher than the

    (default)                                  OFF     SP        PV      OFF       SP          PV   SP by the deviation or more.

                                                       X                                 X          Set the downward deviation in the set point by setting the

    3          Lower-limit                     ON                        ON                         alarm value (X). The alarm is ON when the PV is lower than

                                               OFF     SP        PV      OFF       SP          PV

                                                                                                    the SP by the deviation or more.

                                                                                                    Set the upward deviation in the set point for the alarm upper

               Upper- and lower-limit          ON      L     H                                      limit (H) and the lower deviation in the set point for the alarm

    4          range *1                        OFF               PV      *3                         lower limit (L). The alarm is ON when the PV is inside this de-

                                                       SP

                                                                                                    viation range.

               Upper- and lower-limit          ON      L     H                                      A standby sequence is added to the upper- and lower-limit

    5          with standby sequence *1        OFF               PV      *4                         alarm (1). *6

                                           *5          SP

               Upper-limit with standby        ON            X           ON        X

    6          sequence                        OFF               PV      OFF                   PV   A standby sequence is added to the upper-limit alarm (2). *6

                                                       SP                          SP

               Lower-limit with standby        ON      X                 ON              X

    7          sequence                        OFF               PV      OFF                   PV   A standby sequence is added to the lower-limit alarm (3). *6

                                                       SP                          SP

               Absolute-value upper-lim-       ON         X              ON           X             The alarm will turn ON if the process value is larger than the

    8          it                              OFF               PV      OFF                   PV   alarm value (X) regardless of the set point.

                                                    0                                       0

                                               ON         X              ON           X             The alarm will turn ON if the process value is smaller than the

    9          Absolute-value lower-limit      OFF               PV      OFF                   PV   alarm value (X) regardless of the set point.

                                                    0                                       0

               Absolute-value upper-lim-       ON         X              ON           X             A standby sequence is added to the absolute-value upper-

    10         it with standby sequence        OFF               PV      OFF                   PV   limit alarm (8). *6

                                                    0                                       0

               Absolute-value lower-limit      ON         X              ON           X             A standby sequence is added to the absolute-value lower-

    11         with standby sequence           OFF               PV      OFF                   PV   limit alarm (9). *6

                                                    0                                       0

    12         LBA (alarm 1 type only)                                -                             *7

    13         PV change rate alarm                                   -                             *8

               SP absolute-value               ON         X              ON           X             This alarm type turns ON the alarm when the set point (SP)

    14         upper-limit alarm               OFF               SP      OFF                   SP   is higher than the alarm value (X).

                                                    0                                       0

               SP absolute-value               ON         X              ON           X             This alarm type turns ON the alarm when the set point (SP)

    15         lower-limit alarm               OFF               SP      OFF                   SP   is lower than the alarm value (X).

                                                    0                                       0

                                           Standard Control              Standard Control

                                               ON         X              ON           X

                                               OFF  0            MV      OFF                   MV

               MV absolute-value                                                            0       This alarm type turns ON the alarm when the manipulated

    16         upper-limit alarm *9        Heating/Cooling               Heating/Cooling            variable (MV) is higher than the alarm value (X).

                                           Control (Heating MV)          Control (Heating MV)

                                               ON         X

                                               OFF  0            MV      Always ON

                                           Standard Control              Standard  Control

                                               ON         X              ON           X

                                               OFF  0            MV      OFF                0  MV

    17         MV absolute-value           Heating/Cooling                                          This alarm type turns ON the alarm when the manipulated

               lower-limit alarm *9        Control (Cooling MV)          Heating/Cooling            variable (MV) is lower than the alarm value (X).

                                                                         Control (Cooling MV)

                                               ON         X

                                               OFF  0            MV      Always ON

               RSP absolute-value              ON         X              ON           X             This alarm type turns ON the alarm when the remote SP

    18         upper-limit alarm *10           OFF               RSP     OFF                   RSP  (RSP) is higher than the alarm value (X).

                                                    0                                       0

               RSP absolute-value              ON         X              ON           X             This alarm type turns ON the alarm when the remote SP

    19         lower-limit alarm *10           OFF               RSP     OFF                   RSP  (RSP) is lower than the alarm value (X).

                                                    0                                       0

22
                                                                                                                               E5CC/E5CC-U

*1  With set values 1, 4 and 5, the upper and lower limit values can be set       *4   Set value: 5, Upper- and lower-limit with standby sequence

    independently for each alarm type, and are expressed as “L” and “H.”               For Upper- and Lower-Limit Alarm Described Above *2

*2  Set value: 1, Upper- and lower-limit alarm                                         • Case 1 and 2

    Case 1            Case 2                    Case 3 (Always ON)                     Always OFF when the upper-limit and lower-limit hysteresis overlaps.

                                                                       H<0, L<0        • Case 3: Always OFF

            L  H  SP  SP L    H                    H  SP    L

    H<0, L>0          H>0, L<0                                         H<0, L>0   *5.  Set value: 5, Upper- and lower-limit with standby sequence

    |H| < |L|         |H| > |L|                 H     L SP             |H| ≥ |L|       Always OFF when the upper-limit and lower-limit hysteresis overlaps.

                                                                       H>0, L<0   *6   Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.

                                                      SP H          L  |H| ≤ |L|       H174) for information on the operation of the standby sequence.

                                                                                  *7   Refer to the E5@C Digital Temperature Controllers User's Manual (Cat.

*3  Set value: 4, Upper- and lower-limit range                                         No.H174)  for information on the loop burnout alarm (LBA).

    Case 1            Case 2     Case 3 (Always OFF)                              *8   Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.

                                                                       H<0, L<0        H174) for information on the PV change rate alarm.

    L          H  SP  SP L    H                    H  SP    L                     *9   When heating/cooling control is performed, the MV absolute upper limit

    H<0, L>0          H>0, L<0                                         H<0, L>0        alarm functions only for the heating operation and the MV absolute lower

    |H| < |L|         |H| > |L|                 H     L SP             |H| ≥ |L|       limit alarm functions only for the cooling operation.

                                                                       H>0, L<0   *10  This value is displayed only when a remote SP input is used. It functions in

                                                                       |H| ≤ |L|       both Local SP Mode and Remote SP Mode.

                                                      SP H     L                       Remote SP input is supported only for the E5CC.

                                                                                                                                                                     23
E5CC/E5CC-U

Characteristics

                                           E5CC

                                           Thermocouple:    (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1

                                           Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max.

    Indication accuracy                    Analog input:    ±0.2% FS ±1 digit max.

    (at the ambient temperature of 23°C)   CT input:        ±5% FS ±1 digit max.

                                           E5CC-U

                                           Thermocouple:    (±1% of indication value or ±2°C, whichever is greater) ±1 digit max. *1

                                           Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max.

                                           Analog input:    ±0.2% FS ±1 digit max.

    Transfer output accuracy               ±0.3% FS max.

    Simple transfer output accuracy        ±0.3% FS max.*2

    Remote SP Input Type                   ±0.2% FS ±1 digit max.

    Influence of temperature       *3      Thermocouple input (R, S, B, W, PL II): (±1% of indication value or ±10°C, whichever is greater) ±1 digit max.

                                           Other thermocouple input: (±1% of indication value or ±4°C, whichever is greater) ±1 digit max. *4

                                           Platinum resistance thermometer: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max.

    Influence of voltage   *3              Analog input: ±1%FS ±1 digit max.

                                           CT input: ±5% FS ±1 digit max.

                                           Remote SP      input: ±1% FS ±1 digit max.

    Input sampling period                  50 ms

    Hysteresis                             Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                           Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

    Proportional band (P)                  Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                           Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

    Integral time (I)                      0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5

    Derivative time (D)                    0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5

    Proportional band (P) for cooling      Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                           Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

    Integral time (I) for cooling          0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5

    Derivative time (D) for cooling        0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5

    Control period                         0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)

    Manual reset value                     0.0 to 100.0% (in units of 0.1%)

    Alarm setting range                    -1999 to 9999 (decimal point position depends on input type)

    Influence of signal source resistance  Thermocouple: 0.1°C/Ω max. (100 Ωmax.)

                                           Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.)

    Insulation resistance                  20 MΩ min. (at 500 VDC)

    Dielectric strength                    3,000 VAC, 50/60 Hz for 1 min between terminals of different charge

    Vibration   Malfunction                10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions

                Resistance                 10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions

    Shock       Malfunction                100 m/s2, 3 times each in X, Y, and Z directions

                Resistance                 300 m/s2, 3 times each in X, Y, and Z directions

    Weight                                 E5CC: Controller: Approx. 120 g, Adapter: Approx. 10 g

                                           E5CC-U: Controller: Approx. 100 g, Adapter: Approx. 10 g

    Degree of protection                   E5CC: Front panel: IP66, Rear case: IP20, Terminals: IP00

                                           E5CC-U: Front panel: IP50, Rear case: IP20, Terminals: IP00

    Memory protection                      Non-volatile memory (number of writes: 1,000,000 times)

    Setup Tool                             E5CC: CX-Thermo version 4.5 or higher

                                           E5CC-U: CX-Thermo version 4.61 or higher

    Setup Tool port                        E5CC/E5CC-U top panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect to a USB

                                                                    port on the computer. *6

    Standards   Approved standards         UL 61010-1*7, KOSHA certified (some models) *8, Korean Radio Waves Act (Act 10564)

                Conformed standards        EN 61010-1 (IEC 61010-1): Pollution Degree 2, overvoltage category II, Lloyd's standards *9

                                           EMI:                                                           EN61326

                                           Radiated Interference Electromagnetic Field Strength:          EN 55011 Group 1, class A

                                           Noise Terminal Voltage:                                        EN 55011 Group 1, class A

                                           EMS:                                                           EN 61326

    EMC                                    ESD Immunity:                                                  EN 61000-4-2

                                           Electromagnetic Field Immunity:                                EN 61000-4-3

                                           Burst Noise Immunity:                                          EN 61000-4-4

                                           Conducted Disturbance Immunity:                                EN 61000-4-6

                                           Surge Immunity:                                                EN 61000-4-5

                                           Voltage Dip/Interrupting Immunity:                             EN 61000-4-11

*1  The indication accuracy of K thermocouples in the -200 to 1,300°C range, T and N thermocouples at a temperature of -100°C max., and U and

    L thermocouples at any temperatures is ±2°C ±1 digit max. The indication accuracy of the B thermocouple at a temperature of 400°C max. is

    not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800°C is ±3°C max. The indication accuracy of the R and

    S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W thermocouples is (±0.3% of PV or ±3°C,

    whichever is greater) ±1 digit max. The indication accuracy of PL II thermocouples is (±0.3% of PV or ±2°C, whichever is greater) ±1 digit max.

*2  However, the precision between 0 and 4 mA for a 0 to 20 mA output is ±1% FS max.

*3  Ambient temperature: -10°C to 23°C to 55°C, Voltage range: -15% to 10% of rated voltage

*4  K thermocouple at -100°C max.: ±10°C max.

*5  The unit is determined by the setting of the Integral/Derivative Time Unit parameter.

*6  External communications (RS-485) and USB-serial conversion cable communications can be used at the same time.

*7  The E5CC-U plug-in model is certified for UL listing only when used together with the OMRON P2CF-11 or P2CF-11-E Socket. The P3GA-11

    is not certified for UL listing.

*8  Access the following website for information on certified models. http://www.ia.omron.com/support/models/index.html

*9  Refer to information on maritime standards in Shipping Standards on page 106 for compliance with Lloyd's Standards.

24
                                                                                                                                                   E5CC/E5CC-U

USB-Serial Conversion Cable                                                                                                    When Digital Temperature Controllers are con-

                                                                                                                               nected, set points and RUN/STOP commands

Applicable OS           Windows XP/Vista/7/8                                                                                   can be sent from the Digital Temperature Control-

                        CX-Thermo version 4.5 or higher (Version 4.61 or    Component                                          ler that is set as the master to the Digital Temper-

Applicable software     higher is required for the E5CC-U.)                 Communications*1                                   ature Controllers that are set as slaves.

                                                                                                                               Slope and offsets can be set for the set point.

Applicable models       E5@C-T Series, E5@C Series, and E5CB Series                                                            Number of connected Digital Temperature Con-

USB interface standard  Conforms to USB Specification 2.0.                                                                     trollers: 32 max. (including master)

DTE speed               38400 bps                                                                                              When Digital Temperature Controllers are con-

                                                                                                                               nected, the parameters can be copied from the

Connector               Computer: USB (type A plug)                         Copying*2                                          Digital Temperature Controller that is set as the

specifications          Digital Temperature Controller:                                                                        master to the Digital Temperature Controllers that

                        Special serial connector                                                                               are set as slaves.

Power supply            Bus power (Supplied from USB host controller.)*     MELSEC is a registered trademark of Mitsubishi Electric Corporation.

Power supply voltage    5 VDC                                               KEYENCE is a registered trademark of Keyence Corporation.

Current consumption     450 mA max.                                         *1                       A Temperature Controller with version 1.1 or higher is required.

                        4.7±0.2 VDC                                                                  A Temperature Controller with version 2.1 or higher is required for

Output voltage          (Supplied from USB-Serial Conversion Cable to                                the FX Series or the KV Series.

                        the Digital Temperature Controller.)                *2                       Both the programless communications and the component

                        250 mA max.                                                                  communications support the copying.

Output current          (Supplied from USB-Serial Conversion Cable to       Current Transformer (Order Separately)

                        the Digital Temperature Controller.)

Ambient operating       0 to 55°C (with no condensation or icing)           Ratings

temperature

Ambient operating       10% to 80%                                          Dielectric strength                                1,000 VAC for 1 min

humidity                                                                    Vibration resistance                               50 Hz, 98 m/s2

Storage temperature     -20 to 60°C (with no condensation or icing)                                                            E54-CT1: Approx. 11.5 g,

Storage humidity        10% to 80%                                          Weight                                             E54-CT3: Approx. 50 g

Altitude                2,000 m max.                                        Accessories                                        Armatures (2)

Weight                  Approx. 120 g                                       (E54-CT3 only)                                     Plugs (2)

Windows is a registered trademark of Microsoft Corporation in the

United States and or other countries.                                       Heater Burnout Alarms and SSR Failure

* Use a high-power port for the USB port.                                   Alarms

Note: A driver must be installed on the computer. Refer to the

Instruction Manual included with the Cable for the installation                                                                Models with detection for single-phase

procedure.                                                                  CT input (for heater                               heaters: One input

Communications Specifications                                               current detection)                                 Models with detection for singlephase or

                                                                                                                               three-phase heaters: Two inputs

Transmission line       RS-485: Multidrop                                   Maximum heater                                     50 A AC

connection method                                                           current

Communications          RS-485 (two-wire, half duplex)                      Input current                                      ±5% FS ±1 digit max.

Synchronization         Start-stop synchronization                          indication accuracy

method                                                                      Heater burnout

Protocol                CompoWay/F, or Modbus                               alarm setting range                                0.1 to 49.9 A (in units of 0.1 A)

Baud rate*              9600, 19200, 38400, or 57600 bps                    *1                                                 Minimum detection ON time: 100 ms *3

Transmission code       ASCII                                               SSR failure alarm                                  0.1 to 49.9 A (in units of 0.1 A)

Data bit length*        7 or 8 bits                                         setting range *2                                   Minimum detection OFF time: 100 ms *4

Stop bit length*        1 or 2 bits                                         *1                       For heater burnout alarms, the heater current will be measured

                        Vertical parity (none, even, odd)                                            when the control output is ON, and the output will turn ON if the

Error detection         Block check character (BCC) with                                             heater current is lower than the set value (i.e., heater burnout

                        CompoWay/F or CRC-16 Modbus                                                  detection current value).

Flow control            None                                                *2                       For SSR failure alarms, the heater current will be measured when

Interface               RS-485                                                                       the control output is OFF, and the output will turn ON if the heater

Retry function          None                                                                         current is higher than the set value (i.e., SSR failure detection

Communications buffer   217 bytes                                                                    current value).

Communications          0 to 99 ms                                          *3                       The value is 30 ms for a control period of 0.1 s or 0.2 s.

response wait time      Default: 20 ms                                      *4                       The value is 35 ms for a control period of 0.1 s or 0.2 s.

* The baud rate, data bit length, stop bit length, and vertical parity can  Electrical Life Expectancy Curve for

be individually set using the Communications Setting Level.                 Relays (Reference Values)

Communications Functions                                                    Life (× 104 operations)  500

                        You can use the memory in the PLC to read and                                300

                        write E5@C parameters, start and stop operation,

                        etc. The E5@C automatically performs communi-

                        cations with PLCs. No communications program-                                100

                        ming is required.

                        Number of connected Digital Temperature Con-                                 50

                        trollers: 32 max. (Up to 16 for the FX Series)                               30

Programless             Applicable PLCs

communications*1        OMRON PLCs

                              CS Series, CJ Series, or                                               10

                              CP Series

                        Mitsubishi Electric PLCs                                                     5       E5CC

                              MELSEC Q Series, L Series, or FX Series                                3       250 VAC, 30 VDC

                              (compatible with the FX2 or FX3 (excluding                                     (resistive load)

                              the FX1S))                                                                     cosφ = 1

                        KEYENCE PLCs                                                                 1

                              KEYENCE KV Series                                                           0  1         2       3  4       5        6

                                                                                                                                  Switching current (A)

                                                                                                                                                                                     25
E5CC/E5CC-U

External Connections

E5CC

          Control output 1

       Relay output                                                                                                  E5CC- @ @             3  @       5      M - @@@

       250 VAC, 3A                                                                                                                    (1)  (2) (3) (4) (5)              (6)

       (resistive load)

       Voltage output                                                                                                                                     ↑

       (for driving SSR)                                                          Auxiliary outputs 1, 2, 3                                   Terminal type

       12 VDC, 21 mA                             Control output 2              Relay outputs

       Linear current output                     Voltage output                Models with 3 auxiliary                    The E5CC is set for a K-type thermocouple (input type = 5) by

       0 to 20 mA DC                                                           outputs: 250 VAC, 2 A                      default. An input error (s.err) will occur if the input type setting does

       4 to 20 mA DC                             (for driving SSR)             (resistive load)

       Load: 500 Ω max.                          12 VDC, 21 mA                                                            not agree with the temperature sensor. Check the input type.

    (1) Control outputs 1, 2                                                      QQ

             RX                 QX                            CX                                                     CQ

    Models with             Models with 1                 Models with          Models with 2                   Models with 2 Outputs: Linear Current               (2) Auxiliary Outputs

    1 Relay                 Voltage Output                1 Linear             Voltage Outputs                 Output and Voltage (for Driving SSR)                     Auxiliary outputs 1, 2, 3

    Output                  (for Driving SSR)             Current Output       (for Driving SSR)

          1           OUT1  1               OUT1          1              OUT1  1             OUT1                 1             OUT1                                         7
                                                                      +                   +Q                                +C                                                      Auxiliary output 3
                      R                  +  Q                            C                                                                                                   8
                                         -
          2                 2                             2           -        2          -  Q                    2          -  Q                                                   Auxiliary output 2

          3                 3                             3                    3          +  OUT2                 3         +   OUT2                                         9      Auxiliary output 1

                                                                                                                                                                             10      ●  ●

                                                                                                               1            13         7

                                                                                                               2            14         8

    (5) Sensor (Temperature/Analog) Input                                                                      3            15         9                           (3) Input Power Supply

             TC             Pt              I             V                                                    4            16         10                            100 to 240 VAC        24 VAC/DC

                 4      A   4            +  4             4                                                    5            17         11

          -             B       mA                     -                                                       6            18         12                               11                         11

                 5       B  5            -  5             5

                 6          6               6       V     6                                                                                                             12                         12

          +                                            +

                                                                                                                                                                                           (no polarity)

    (6) Options

       001                                  003                             004                                      005                              006                                  007

       Event Inputs 1                       Communications                  Communications                           Event Inputs                     Event Inputs                         Event Inputs

       and 2, and CT1                       (RS-485), CT1,                  (RS-485), and                            1 to 4                           1 and 2, and                         1 and 2, and

                                            and CT2                         Event Inputs 3 and              4                                         Transfer Output                      Remote SP Input

       -            13                              B(+)  13                      B(+)       13                      -             13                        -          13                                 13

                                               RS-485                             RS-485                                                                                                   -

          +         14                                    14                                 14                          +         14                           +       14                         +       14
             EV1
    +                                               A(-)                          A(-)                               +      EV1                              +     EV1                     +          EV1

    EV2             15                                    15                                 15                         EV2        15                           EV2     15                      EV2        15

                    16                                    16                   -             16                      -             16                                   16          +      +               16

    CT1             17                         CT1        17                      +          17                          +         17                                   17   +V                    V   +   17

                                                    COM                              EV3                                    EV3                                                                       mA

                    18                      CT2           18                   +             18                      +             18                                   18   I      -           -          18

                                                                                  EV4                                   EV4

E5CC-U

                                            The E5CC-U is set for a K-type thermocouple (input type =                            E5CC-                UM-000

                                            5) by default. An input error (s.err) will occur if the input                          Control output 1

                                            type setting does not agree with the temperature sensor.

                                            Check the input type.                                                                      Auxiliary outputs 1, 2

                                                                                                                                   Relay output

                                                                                                                                   250 VAC, 3 A (resistive load)

                                                                                       Control output 1

                                                                                                                                      Auxiliary output 1

                                                                   I                                                                             Auxiliary output 2:

                                                                      +                      Pt  A                                               Control output (cooling     side)

                                                              mA               V       TC

                                                                               −       −         B

                                                                      −     V

                                                                               +       +         B                                    Input power supply

                                                                      Sensor (temperature/analog) input                                    • 100 to 240 VAC

          Control output 1                                                                                                                 • 24 VAC/DC (no polarity)

    Voltage output (for driving SSR)                      Control output 1:

    12 VDC, 21 mA                                                        QX                                          CX                                      RW

    Linear current output                                     Models with 1                                    Models with 1                          Models with 1

    4 to 20 mA DC                                             Voltage Output                                   Linear Current                         Relay Output

    0 to 20 mA DC                                             (for Driving SSR)                                Output

    Load: 500 Ω max.                                               −                                           −                           Output 1

    Relay output (three terminals used)                   Output 1                               Output 1                                     R

    SPDT, 250 VAC, 3 A                                        Q    +                                     C

    (resistive load)                                                                                           +

Note: 1.            The application of the terminals depends on the model.

             2.     Do not wire the terminals that are shown with a gray background.

             3.     When complying with EMC standards, the cable that connects the sensor must be 30 m or less.

                    If the cable length exceeds 30 m, compliance with EMC standards will not be possible.

             4.     Connect M3 crimped terminals.

                    Connect M3.5 crimped terminals for the E5CC-U.

26
                                                                                                                                                               E5CC/E5CC-U

Isolation/Insulation Block Diagrams

• E5CC

Models with 3 Auxiliary Outputs

              Sensor input, CT inputs, and remote SP input

              Communications and event inputs

      Power   Voltage output (for driving SSR),

      supply  linear current output, and transfer output

                                       Relay output

                                      Auxiliary outputs 1, 2, 3

              : Reinforced insulation

              : Functional isolation

Note: Auxiliary outputs 1 to 3 are not insulated.

• E5CC-U

Models with 2 Auxiliary Outputs

                                       Sensor input

      Power   Voltage output (for driving SSR) and linear current output

      supply

                                       Relay output

                                      Auxiliary outputs 1 and 2

              : Reinforced insulation

              : Functional isolation

Nomenclature

E5CC                                                             Front panel

E5CC-U        Temperature unit                                                                                     Top View of E5CC  Top View of E5CC-U

              Operation indicators                                                No. 1 display

                                                                                  PV or specified parameter

                                                                                  No. 2 display

                                                                                  SP or specified parameter value

                                                                                  Use the U D Keys to set the

                                                                                  parameter.

                                                                                                                                    Top-panel Setup Tool port

              Press O Key once to go to Adjustment Level.                         Use S Key to change the digit (default setting).

              Press O Key for at least 3 seconds to go to Initial Setting Level.

                                                                                  Use the M Key to change to another parameter.

                                                                                                                                                                            27
E5CC/E5CC-U

Dimensions                                                                                                                                                     (Unit: mm)

Controllers

E5CC

                                           4            73.1

                                                        60

                 48 × 48                         1                                                           48 × 48

                                                                      44.8 × 44.8  48.8             58

                       Waterproof Packing           Mounting Adapter

                       (Accessory)                  (Accessory)       Terminal Cover

                                                                      (E53-COV17)

                                                                      (Sold separately)

             The Setup Tool port is on the top of the Temperature Controller.

             It is used to connect the Temperature Controller to the computer to use the Setup Tool.

             The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection.

             Refer to the instructions that are provided with the USB-Serial Conversion Cable for the connection procedure.

             Note: Do not leave the USB-Serial Conversion Cable connected when you use the Temperature Controller.

                                           Panel Cutout

             Mounted Separately                                   Group Mounted

                                                                 (48 × number of units - 2.5)+10.0

                                                                                                        •  Recommended panel thickness is 1 to 5 mm.

                                                                                   45+00.6              •  Group mounting is not possible in the vertical direction. (Maintain

                                                                                                           the specified mounting space between Controllers.)

             60 min.                                                                                    •  To mount the Controller so that it is waterproof, insert the

                                                                                                           waterproof packing onto the Controller.

                                        45+00.6                                                         •  When two or more Controllers are mounted, make sure that the

                                                                                                           surrounding temperature does not exceed the allowable operating

                                                                                                           temperature specified in the specifications.

                          45+00.6                                                                       •  Use a control panel thickness of 1 to 3 mm if the Y92A-48N and a

                                                                                                           USB-Serial Conversion Cable are used together.

E5CC-U                                                      76.8

                      48 × 48           4               58.6          14.2

                                                                                                    48 × 48

                                                                      58

                                                    Mounting Adapter

                                                    (Accessory)

             The Setup Tool port is on the top of the Temperature Controller.

             It is used to connect the Temperature Controller to the computer to use the Setup Tool.

             The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection.

             Refer to the instructions that are provided with the USB-Serial Conversion Cable for the connection procedure.

             Note: Do not leave the USB-Serial Conversion Cable connected when you use the Temperature Controller.

                                                 Panel  Cutout

                 Mounted Separately                               Group Mounted

                                                                  (48 × number of units - 2.5)+10.0

                                                                                                        • Recommended panel thickness is 1 to 5 mm.

                                                                                      45+00.6           • Group mounting is not possible in the vertical direction. (Maintain

                                                                                                           the specified mounting space between Controllers.)

             60  min.                                                                                   • When two or more Controllers are mounted, make sure that the

                                                                                                           surrounding temperature does not exceed the allowable operating

                                                                                                           temperature specified in the specifications.

                                        45+00.6                                                         • Use a control panel thickness of 1 to 3 mm if the Y92A-48N and a

                                                                                                           USB-Serial Conversion Cable are used together.

                               45+00.6

28
                                                                                                                               E5CC/E5CC-U

Accessories (Order Separately)

● USB-Serial Conversion Cable

E58-CIFQ2                                                                                     (2110)

                                                                  250                                              263           1510

                                                                                 LED (RD)

                                             USB connector

                                             (type A plug)                                    LED (PWR)                                Serial connector

                                                                                              LED (SD)

● Terminal Covers                            48                                ● Terminal     Covers

E53-COV17                                                                      E53-COV23      (Three Covers        provided.)

                                                                                                                2  3.8

                           48.8

                                                                                                            10

                                                                                                                                 Terminal Cover

                                                                                                                                 (E53-COV23)

                           22                                                                 44.8

                           9.1

● Terminal Cover (for  the P3GA-11 Back-connecting                      Socket)

Y92A-48G

                                Twelve, 6.4-dia.

                   34      Y92A-48G  UP      47.7×47.7                  48×48

                                       P  C

                                                  16.5      24.6

                                                                  27.6

                                 47.4

                   Note: You  can attach     the P3GA-11 Back-connecting Socket for finger protection.

● Waterproof Packing                              The Waterproof Packing is provided only with the E5CC.

Y92S-P8 (for DIN 48 × 48)                         Order the Waterproof Packing separately if it becomes lost or damaged.

                                                  The Waterproof Packing can be used to achieve an IP66 degree of protection.

                                                  (Deterioration, shrinking, or hardening of the waterproof packing may occur depending on the

                                                  operating environment. Therefore, periodic replacement is recommended to ensure the level of

                                                  waterproofing specified in IP66. The time for periodic replacement depends on the operating

                                                  environment. Be sure to confirm this point at your site.

                                                  Consider three years as a rough standard.)

                                                  The Waterproof Packing does not need to be attached if a waterproof structure is not required.

                                                  The E5CC-U cannot be waterproofed even if the Waterproof Packing is attached.

                                                                                                                                                         29
E5CC/E5CC-U

● Current Transformers

E54-CT1                                                                                Thru-current (Io) vs. Output Voltage (Eo)

                                          21                            2.8

                                          15                                           (Reference Values)

                                                    5.8 dia.                           E54-CT1

                                                                               7.5

                                                                                       Maximum continuous heater current:                                        50 A (50/60 Hz)

                              25      3                                                Number of windings:                                                       400±2

                                                                                       Winding resistance:                                                       18±2 Ω

                                                              10.5

                                                                                       Output voltage (Eo) V (r.m.s.)  100V      Frequency: 50 Hz

                                          40

                                                      Two, 3.5 dia.                                                    10                          ∞                    Distortion

                                                                                                                                     1kΩ                                factor

                                                                                                                                                                        10%

                                      10                                                                               1

                                                                                                                                                                       3%

                                                                                                                                                                   1%

                                          30                                                                           100mV

E54-CT3                                                                                                                10                                100Ω

                                                                    2.36 dia.

                                          30                                                                           1                                 RL=10Ω

                                                    12 dia.

                                                                                    9

                                                                                                                       100μV

                                                                                                                       10

                              40 × 40                                                                                         1  10  100mA            1        10      100     1,000A

                                                                                                                                                         Thru-current (Io) A (r.m.s.)

                                                                                       Thru-current (Io) vs. Output Voltage (Eo)

                                                    Two, M3 (depth: 4)                 (Reference Values)

                                  15                                                   E54-CT3

                                                                                       Maximum continuous heater current:                                      120 A (50/60 Hz)

                                          30                                           (Maximum continuous heater current for an OMRON

                                                                                       Digital Temperature Controller is 50 A.)

E54-CT3 Accessories                                                                    Number of windings:                                                     400±2

    •  Armature                           Connection  Example                          Winding resistance:                                                     8±0.8 Ω

                                                                                       Output voltage (Eo) V (r.m.s.)  100V      Frequency: 50 Hz

                                                              Armature                                                                             ∞                        Distortion

    Approx. 3 dia.                            Plug                                                                     10                                                   factor

                                                                                                                                     1kΩ                                    10%

                                                                             Lead                                                    500Ω                                   3%

                                                                                                                       1                                                   1%

                          18                                                                                           100mV

                                                                                                                                                         100Ω

    • Plug                                                                                                             10                                50Ω

                                                                                                                                                         RL=10Ω

    Approx. 6 dia.                                                                                                     1

                                                                                                                       100μV

                    (22)

                                                                                                                       10     1  10  100mA            1        10      100  1,000A

                                                                                                                                                         Thru-current (Io) A (r.m.s.)

30
                                                                                                                                      E5CC/E5CC-U

● Adapter

Y92F-45    Note: 1.  Use this Adapter when the Front Panel has already been prepared for the E5B@.

                 2.  Only black is available.

                 3.  You cannot use the E58-CIFQ2 USB-Serial Conversion Cable if you use the Y92F-45 Adapter. To use the USB-Serial

                     Conversion Cable to make the settings, do so before you mount the Temperature Controller in the panel.

                                                                                                                     Fixture (Accessory)

                                                                         4.7                        76

                                                                                         69.6 to 77.6

                                               72 × 72

                                                                                                                          67 × 67 87

Mounted to E5CC                                                          Panel (1 to 8 mm)              Mounting Adapter

                                               72 × 72                                                  Y92F-30

                                                                                                        (Accessory)

                                                                48 × 48

                                                                2.2           4.7

                                                                                         62.8

                                                                              To back of the E5CC

● DIN Track Mounting Adapter

Y92F-52    Note: This Adapter cannot be used together with the Terminal Cover.

                 Remove the Terminal Cover to use the Adapter.

                                                                                                                 This Adapter is used to mount the

                                                                                         61                      E5CC to a DIN Track.

                                                                                                                 If you use the Adapter, there is no

                                                                                                                 need for a plate to mount in the

                                                                                                                 panel or to drill mounting holes in

                                                                                               3.5               the panel.

                                               50                        38

Mounted to E5CC

                                                        48

                                                                                   80.5

                                                                                                                                                      31
E5CC/E5CC-U

● Watertight Cover                                                                          ● Mounting Adapter

Y92A-48N                                                                                    Y92F-49

                                                21.9       14                                                                     The Mounting Adapter is provided with the

                                                      (2)                                                                         Temperature Controller.

                                                                                                                                  Order this Adapter separately if it becomes

                                                                                                                                  lost or damaged.

          87.7  79.2                                                 69

                                                                          12

                      67.6                      28.9

● Protective Cover                                                                          ● Protective             Cover

    Y92A-48D          Note: This Protective Cover cannot be used                            Y92A-48H

                            if the Waterproof Packing is installed.                                                               This Protective Cover is hard type.

                         This Protective Cover is soft type.                                                                      Please use it for the mis-operation

                         It is able to operate the controller with using                                                          prevention etc.

                         this cover.

● E5CC-U Wiring Socket

Front-connecting Socket

P2CF-11

                            Eleven, M3.5 × 7.5                            3                 4.5        Terminal  Layout/Internal Connections

                            sems screws                    7.8                                                       (Top View)

                                                                                                                     8  7   6  5                    Mounting Holes

                                                                                                                                  4

                                                                                                                                                    Two, 4.5 dia. mounting holes

                            70 max.                                                         35.4

                                                           Two,                                                                                            40±0.2

                                                           4.5-dia.                                                  9            3

                                                           holes                                                     10 11  1  2                   Note: Can also be mounted

                                                                                                                                                    to a DIN track

                                4            50 max.                          31.2 max.

Note: 1.  A model with finger protection (P2CF-11-E) is also available.

    2.    You cannot use the P2CF-11 or P2CF-11-E together with the                         Y92F-45.

Back-connecting Socket

P3GA-11

                                                                                                       Eleven, M3.5  Terminal Layout/Internal Connections

                                      27dia.                                             4       7  3  sems screws                   (Bottom View)

                                                                                                                                     5  6  7   8

                                                                                                                                     4

                            45                                               25.6

                                                                                                                                     3         9

                                                                                                                                     2  1  11  10

                                         45                4.5 16.3  6.2

                                                                                                                 6

                                                                                   8.7

Note: 1.  Using any other sockets will adversely affect accuracy. Use only the specified sockets.

    2.    A Protective Cover for finger protection (Y92A-48G) is also available.

    3.    You cannot use the P3GA-11 together with the Y92F-45.

    4.    You cannot use this Adapter together with the Y92F-49 Adapter that is provided with the E5CC Temperature Controller.

32
MEMO

      33
    Digital Temperature Controller

    E5EC/E5AC                                                          (48 × 96 mm/96 × 96 mm)

Large White PV Display That’s Easier to Read.

Easy to Use, from Model Selection to

Setup and Operation.

A Complete Range of I/O Capacities,

Functions, and Performance.

Handles More Applications.

    • A white LCD PV display with a height of approx. 18 mm for the

    E5EC and 25 mm for the E5AC improves visibility.

    • Tool ports are provided both on the top panel and the front panel.

    Set up the Controller without wiring the power supply by                        48 × 96 mm                    96 × 96 mm

    connecting to the computer with a Communications Conversion                     E5EC                           E5AC

    Cable (sold separately). Setup is easy with the CX-Thermo (sold

    separately).                                                                    Refer to your OMRON website for the most recent

    • High-speed sampling at 50 ms.                                                 information on applicable safety standards.

    • Models are available with up to 4 auxiliary outputs, up to 6 event

    inputs, a transfer output, and a remote SP input to cover a wide                     Refer to Safety Precautions on page 104.

    range of applications.

    • Short body with depth of only 60 mm.

    • Easy connections to a PLC with programless communications.

    Use component communications to link Temperature Controllers to each other.

    • The new position-proportional control models allow you to control valves as well.

Main I/O Functions

    Sensor Input                            E5EC                       E5AC

    Universal input

    • Thermocouple

    • Pt                                                                                 Three-level Display

    • Analog current/voltage                                                             PV, SV, and MV displayed                4-digit

                                                                                         at the same time.                       displays

          Indication Accuracy

          • Thermocouple input:                                                          Control Output 1

          ±0.3% of PV                                                                    • Relay output

          • Pt input: ±0.2% of PV                                                        • Voltage output (for driving SSR)

          • Analog input: ±0.2% of  FS                                                   • Linear current output

          Sampling Period

          • 50 ms                                                                        Control Output 2

                                                                                         • Voltage output (for driving SSR)

                                                                                         • Relay output

    Event Inputs                                                                         • Linear current output

    • None                                  • PF (shift) Key

    •2                                      • Setup Tool port on front panel             Auxiliary Outputs

    •4                                      • Temperature status display                 •4

    •6                                      • Simple programming

    Remote SP Input                         • Independent heating and                    Transfer Output

    • None                                  cooling PID control

    •1                                      • Changed parameter display                  • None

                                            • Display brightness setting                 •1

    Serial Communications

    • None

    • RS-485

    This datasheet is provided as a guideline for selecting products.

    Be sure to refer to the following manuals for application precautions and other information required for operation before attempting

    to use the product.

        E5@C Digital Temperature Controllers User’s Manual (Cat. No. H174)

        E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)

34
                                                                                                                                        E5EC/E5AC

Model Number Legend and Standard Models

Model Number Legend

●Models with Screw Terminals

E5EC-@@           4  @  5     M -@@@ (Example: E5EC-RX4A5M-000)
           −−     − − − − −−−
            A     BC       DE       F

E5AC-@@           4  @  5     M -@@@ (Example: E5AC-RX4A5M-000)
           −−     − − − − −−−
            A     BC       DE       F

                        A                 B                    C        D         E   F

    Model         Control outputs      No. of auxil-        Power    Terminal  Input                                       Meaning

                     1 and 2              iary out-         supply      type   type   Options

                                          puts              voltage

E5EC                                                                                                              48 × 96 mm

E5AC                                                                                                              96 × 96 mm

                                                                                                         Control output 1               Control output 2

            RX                                                                                               Relay output                       None

            QX                                                                                           Voltage output                         None

                                                                                                         (for driving SSR)

           *2 CX                                                                                         Linear current output                  None

            QQ                                                                                           Voltage output                 Voltage output

                                                                                                         (for driving SSR)              (for driving SSR)

            QR                                                                                           Voltage output                    Relay output

                                                                                                         (for driving SSR)

            RR                                                                                               Relay output                  Relay output

           *2 CC                                                                                         Linear current output          Linear current out-

                                                                                                                                                put

           *2 CQ                                                                                         Linear current output          Voltage output

                                                                                                                                        (for driving SSR)

            PR                                                                                 Position-proportional relay output       Position-proportion-

                                                                                                                                        al relay output

                                   *3  4                                                       4 (auxiliary outputs 1 and 2 with same common and auxilia-

                                                                                                         ry outputs 3 and 4 with same common)

                                                            A                                                100 to 240 VAC

                                                            D                                                     24 VAC/DC

                                                                     5                                       Screw terminals (with cover)

                  Control outputs 1    and 2                                   M                             Universal input

            For RX,

            QX, QQ,     For CX or      For PR                                                  HB alarm                         Event   Remote     Transfer

            QR, RR, or  CC                                                                     and           Communications     inputs  SP Input   output

            CQ                                                                                 HS alarm

            Selectable  Selectable     Selectable                                     000           ---      ---                ---        ---        ---

Option                  Selectable     Selectable                                     004           ---      RS-485             2          ---        ---

selection               Selectable                                                    005           ---      ---                4          ---        ---

conditions                                                                                          2

*1          Selectable                                                                009      (for 3-phase  RS-485             2          ---        ---

                                                                                               heaters)

            Selectable                                                                010           1        ---                4          ---        ---

            Selectable                                                                011           1        ---                6       Provided.  Provided.

                        Selectable                                                    013           ---      ---                6       Provided.  Provided.

                        Selectable     Selectable                                     014           ---      RS-485             4       Provided.  Provided.

*1.  The options that can be selected depend on the type of control output.

*2.  The control output cannot be used as a transfer output.

*3.  A model with four auxiliary outputs must be selected.

Heating and Cooling Control

l    Using Heating and Cooling Control

A Control Output Assignment

If there is no control output 2, an auxiliary output is used as the cooling control output.

If there is a control output 2, the two control outputs are used for heating and cooling.

(It does not matter which output is used for heating and which output is used for cooling.)

B Control

If PID control is used, you can set PID control separately for heating and cooling.

This allows you to handle control systems with different heating and cooling response characteristics.

                                                                                                                                                              35
E5EC/E5AC

Optional Products (Order Separately)

USB-Serial Conversion Cable                                           Current Transformers (CTs)

                 Model                                                Hole diameter         Model

           E58-CIFQ2                                                  5.8 mm                E54-CT1

Communications Conversion Cable                                       12.0 mm               E54-CT3

                 Model                                                CX-Thermo Support Software

           E58-CIFQ2-E                                                               Model

Note: Always use this product together with the E58-CIFQ2.                   EST2-2C-MV4

    This Cable is used to connect to the front-panel Setup Tool       Note: CX-Thermo version 4.5 or higher is required for the E5EC/

    port.                                                             E5AC.

Terminal Covers                                                       For the system requirements for the CX-Thermo, refer to

                                                                      information on the EST2-2C-MV4 on the OMRON website

                 Model                                                (www.ia.omron.com).

    E53-COV24 (3pcs)

Note: The Terminal Covers E53-COV24 are provided with the Digital

    Temperature Controller.

Waterproof Packing

    Applicable Controller    Model

    E5EC                     Y92S-P9

    E5AC                     Y92S-P10

Note: This Waterproof Packing is provided with the Digital

    Temperature Controller.

Waterproof Cover

    Applicable Controller    Model

    E5EC                     Y92A-49N

    E5AC                     Y92A-96N

Front Port Cover

                 Model

           Y92S-P7

Note: This Front Port Cover is provided with the Digital Temperature

    Controller.

Mounting Adapter

                 Model

           Y92F-51 (2pcs)

Note: This Mounting Adapter is provided with the Digital Temperature

    Controller.

36
                                                                                                                       E5EC/E5AC

Specifications

Ratings

Power supply voltage                   A in model number: 100 to 240 VAC, 50/60 Hz

                                       D in model number: 24 VAC, 50/60 Hz; 24 VDC

Operating voltage range                85% to 110% of rated supply voltage

                                       Models with option selection of 000:6.6 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or

                                 E5EC                                          2.3 W max. at 24 VDC

Power consumption                      All other models: 8.3 VA max. at 100 to 240 VAC, and 5.5 VA max. at 24 VAC or 3.2 W max. at 24 VDC

                                       Models with option selection of 000:7.0 VA max. at 100 to 240 VAC, and 4.2 VA max. at 24 VAC or

                                 E5AC                                          2.4 W max. at 24 VDC

                                       All other models: 9.0 VA max. at 100 to 240 VAC, and 5.6 VA max. at 24 VAC or 3.4 W max. at 24 VDC

                                       Temperature input

                                       Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II

                                       Platinum resistance thermometer: Pt100 or JPt100

Sensor input                           Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C

                                       Analog input

                                       Current input: 4 to 20 mA or 0 to 20 mA

                                       Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

Input impedance                        Current input: 150 Ω max., Voltage input: 1 MΩ min.

                                       (Use a 1:1 connection when connecting the ES2-HB/THB.)

Control method                         ON/OFF or 2-PID control (with auto-tuning)

              Relay output             SPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations,

                                       minimum applicable load: 5 V, 10 mA (reference value)

Control       Voltage output           Output voltage: 12 VDC ±20% (PNP), max. load current: 40 mA, with short-circuit protection circuit

output        (for driving SSR)        (The maximum load current is 21 mA for models with two control outputs.)

              Linear current output    4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000

Auxiliary     Number of outputs        4

output        Output specifications    SPST-NO. relay outputs, 250 VAC, Models with 4 outputs: 2 A (resistive load),

                                       Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value)

              Number of inputs         2, 4 or 6 (depends on model)

Event input   External contact input   Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.

              specifications           Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.

                                       Current flow: Approx. 7 mA per contact

Transfer      Number of outputs        1 (only on models with a transfer output)

output        Output specifications    Current output: 4 to 20 mA DC, Load: 500 Ω max., Resolution: Approx. 10,000

                                       Linear voltage output: 1 to 5 VDC, load: 1 kΩ min., Resolution: Approx. 10,000

Remote SP input                        Current input: 4 to 20 mA DC or 0 to 20 mA DC (input impedance: 150 Ω max.)

                                       Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V (input impedance: 1 MΩ min.)

Potentiometer input                    100 Ω to 10 kΩ

Setting method                         Digital setting using front panel keys

                                       11-segment digital display and individual indicators

                                       Character height:  E5EC: PV: 18.0 mm, SV: 11.0 mm, MV: 7.8 mm

Indication method                                         E5AC: PV: 25.0 mm, SV: 15.0 mm, MV: 9.5 mm

                                       Three displays Contents: PV/SV/MV, PV/SV/Multi-SP, or PV/SV/Remaining soak time

                                       Numbers of digits: 4 digits each for PM, SV, and MV displays

Multi SP                               Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations,

                                       or serial communications.

Bank switching                         None

                                       Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater

                                       burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital

Other functions                        filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root,

                                       MV change rate limit, logic operations, temperature status display, simple programming, moving av-

                                       erage of input value, and display brightness setting

Ambient operating temperature          −10 to 55°C (with no condensation or icing), For 3-year warranty: −10 to 50°C with standard mounting

                                       (with no condensation or icing)

Ambient operating humidity             25% to 85%

Storage temperature                    -25 to 65°C (with no condensation or icing)

Altitude                               2,000 m max.

Recommended fuse                       T2A, 250 VAC, time-lag, low-breaking capacity

Installation environment               Installation Category II, Pollution Degree 2 (IEC 61010-1 compliant)

                                                                                                                                                       37
E5EC/E5AC

Input Ranges

●Thermocouple/Platinum Resistance Thermometer (Universal inputs)

    Sensor                                   Platinum resistance                                                                    Thermocouple                                               Infrared temperature

    type                                      thermometer                                                                                                                                             sensor

    Sensor

    specifica-                                Pt100          JPt100               K               J               T              E  L           U          N     R     S     B     W     PLII  10 to  60 to  115 to  140 to

                                                                                                                                                                                               70°C   120°C  165°C   260°C

                            tion

                                  2300                                                                                                                                             2300

                                  1800                                                                                                                                       1800

                                  1700                                                                                                                           1700  1700

                                  1600

    Temperature range (°C)        1500

                                  1400                                      1300                                                                           1300                          1300

                                  1300

                                  1200

                                  1100

                                  1000  850                                                 850                                     850

                                  900

                                  800

                                  700                                                                                        600

                                  600         500.0          500.0                   500.0

                                  500                                                                400.0  400      400.0                400      400.0

                                  400                                                                                                                                                                                260

                                  300                                                                                                                                                                 120    165

                                  200                 100.0          100.0                                                                                                                     90

                                  100                                                                                                                                        100

                                  -100                0.0            0.0                                                                                         0     0           0     0     0      0      0       0

                                  -200                                               -20.0  -100     -20.0                          -100

                                        -200  -199.9         -199.9         -200                            -200     -199.9  -200         -200     -199.9  -200

    Set value                           0     1       2      3       4      5        6      7        8      9        10      11     12    13       14      15    16    17    18    19    20    21     22     23      24

                            Shaded settings are the default settings.

The applicable standards for the input types are as follows:

K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 60584-1                                                 JPt100: JIS C 1604-1989, JIS C 1606-1989

L: Fe-CuNi, DIN 43710-1985                                                                           Pt100: JIS C 1604-1997, IEC 60751

U: Cu-CuNi, DIN 43710-1985                                                                           PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)

W: W5Re/W26Re, ASTM E988-1990

●Analog input

    Input type                                            Current                                    Voltage

    Input                                     4 to 20 mA     0 to 20 mA           1 to 5 V           0 to 5 V        0 to 10 V

    specification

                                              Usable in the following ranges by scaling:

    Setting range                             -1999 to 9999, -199.9 to 999.9,

                                              -19.99 to 99.99 or -1.999 to 9.999

    Set value                                         25             26              27                 28                   29

38
                                                                                                                                          E5EC/E5AC

Alarm Types

Each alarm can be independently set to one of the following 19 alarm types. The default is 2: Upper limit. (see note.)

Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.

Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed.

    To use alarm 1, set the output assignment to alarm 1.

Set                                                Alarm output operation

value          Alarm type              When alarm value X            When alarm value X                              Description of function

                                                is positive               is negative

0          Alarm function OFF                                Output OFF                         No alarm

                                                                                                Set the upward deviation in the set point for the alarm upper

                                           ON      L     H                                      limit (H) and the lower deviation in the set point for the alarm

1          Upper- and lower-limit *1       OFF               PV      *2                         lower limit (L). The alarm is ON when the PV is outside this

                                                   SP

                                                                                                deviation range.

2                                                        X           ON        X                Set the upward deviation in the set point by setting the alarm

           Upper-limit                     ON                                                   value (X). The alarm is ON when the PV is higher than the

(default)                                  OFF     SP        PV      OFF       SP          PV

                                                                                                SP by the deviation or more.

                                           ON      X                 ON              X          Set the downward deviation in the set point by setting the

3          Lower-limit                     OFF               PV      OFF                   PV   alarm value (X). The alarm is ON when the PV is lower than

                                                   SP                          SP               the SP by the deviation or more.

                                                                                                Set the upward deviation in the set point for the alarm upper

           Upper- and lower-limit          ON      L     H                                      limit (H) and the lower deviation in the set point for the alarm

4          range *1                        OFF               PV      *3                         lower limit (L). The alarm is ON when the PV is inside this de-

                                                   SP

                                                                                                viation range.

           Upper- and lower-limit          ON      L     H                                      A standby sequence is added to the upper- and lower-limit

5          with standby sequence *1        OFF               PV      *4                         alarm (1). *6

                                       *5          SP

           Upper-limit with standby        ON            X           ON        X

6          sequence                        OFF               PV      OFF                   PV   A standby sequence is added to the upper-limit alarm (2). *6

                                                   SP                          SP

           Lower-limit with standby        ON      X                 ON              X

7          sequence                        OFF               PV      OFF                   PV   A standby sequence is added to the lower-limit alarm (3). *6

                                                   SP                          SP

           Absolute-value upper-lim-       ON         X              ON           X             The alarm will turn ON if the process value is larger than the

8          it                              OFF               PV      OFF                   PV   alarm value (X) regardless of the set point.

                                                0                                       0

                                           ON         X              ON           X             The alarm will turn ON if the process value is smaller than the

9          Absolute-value lower-limit      OFF               PV      OFF                   PV   alarm value (X) regardless of the set point.

                                                0                                       0

           Absolute-value upper-lim-       ON         X              ON           X             A standby sequence is added to the absolute-value upper-

10         it with standby sequence        OFF               PV      OFF                   PV   limit alarm (8). *6

                                                0                                       0

           Absolute-value lower-limit      ON         X              ON           X             A standby sequence is added to the absolute-value lower-

11         with standby sequence           OFF               PV      OFF                   PV   limit alarm (9). *6

                                                0                                       0

12         LBA (alarm 1 type only)                                -                             *7

13         PV change rate alarm                                   -                             *8

           SP absolute-value               ON         X              ON           X             This alarm type turns ON the alarm when the set point (SP)

14         upper-limit alarm               OFF               SP      OFF                   SP   is higher than the alarm value (X).

                                                0                                       0

           SP absolute-value               ON         X              ON           X             This alarm type turns ON the alarm when the set point (SP)

15         lower-limit alarm               OFF               SP      OFF                   SP   is lower than the alarm value (X).

                                                0                                       0

                                       Standard Control              Standard Control

                                           ON         X              ON           X

                                           OFF  0            MV      OFF                   MV

           MV absolute-value                                                            0       This alarm type turns ON the alarm when the manipulated

16         upper-limit alarm *9        Heating/Cooling               Heating/Cooling            variable (MV) is higher than the alarm value (X).

                                       Control (Heating MV)          Control (Heating MV)

                                           ON         X

                                           OFF  0            MV      Always ON

                                       Standard Control              Standard  Control

                                           ON         X              ON           X

                                           OFF  0            MV      OFF                0  MV

17         MV absolute-value           Heating/Cooling                                          This alarm type turns ON the alarm when the manipulated

           lower-limit alarm *9        Control (Cooling MV)          Heating/Cooling            variable (MV) is lower than the alarm value (X).

                                                                     Control (Cooling MV)

                                           ON         X

                                           OFF  0            MV      Always ON

           RSP absolute-value              ON         X              ON           X             This alarm type turns ON the alarm when the remote SP

18         upper-limit alarm *10           OFF               RSP     OFF                0  RSP  (RSP) is higher than the alarm value (X).

                                                0

           RSP absolute-value              ON         X              ON           X             This alarm type turns ON the alarm when the remote SP

19         lower-limit alarm *10           OFF               RSP     OFF                   RSP  (RSP) is lower than the alarm value (X).

                                                0                                       0

                                                                                                                                                                  39
E5EC/E5AC

*1   With set values 1, 4 and 5, the upper and lower limit values can be set       *4.  Set value: 5, Upper- and lower-limit with standby sequence

     independently for each alarm type, and are expressed as “L” and “H.”                  For Upper- and Lower-Limit Alarm Described Above *2

*2.  Set value: 1, Upper- and lower-limit alarm                                         • Case 1 and 2

     Case 1         Case 2                       Case 3 (Always ON)                        Always OFF when the upper-limit and lower-limit hysteresis overlaps.

                                                                        H<0, L<0

     L       H  SP  SP L    H                       H  SP    L                          •  Case 3: Always OFF

     H<0, L>0       H>0, L<0                                            H<0, L>0   *5.  Set value: 5, Upper- and lower-limit with standby sequence

     |H| < |L|      |H| > |L|                    H     L SP             |H| ≥ |L|       Always OFF when the upper-limit and lower-limit hysteresis overlaps.

                                                                        H>0, L<0   *6.  Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.

                                                       SP H          L  |H| ≤ |L|       H174) for information on the operation of the standby sequence.

*3.  Set value: 4, Upper- and lower-limit range                                    *7.  Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.

                                                                                        H174) for information on the loop burnout alarm (LBA). This setting cannot

     Case 1         Case 2     Case 3 (Always OFF)                                      be used with a position-proportional model.

                                                                        H<0, L<0   *8.  Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.

     L       H  SP  SP L    H                       H  SP    L                          H174) for information on the PV change rate alarm.

     H<0, L>0       H>0, L<0                                            H<0, L>0   *9.  When heating/cooling control is performed, the MV absolute upper limit

     |H| < |L|      |H| > |L|                    H     L SP             |H| ≥ |L|       alarm functions only for the heating operation and the MV absolute lower

                                                                        H>0, L<0        limit alarm functions only for the cooling operation.

                                                       SP H     L       |H| ≤ |L|  *10. This value is displayed only when a remote SP input is used. It functions in

                                                                                        both Local SP Mode and Remote SP Mode.

40
                                                                                                                                        E5EC/E5AC

Characteristics

                                   Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1

Indication accuracy                Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max.

(at the ambient temperature of     Analog input: ±0.2% FS ±1 digit max.

23°C)                              CT input: ±5% FS ±1 digit max.

                                   Potentiometer input: ±5% FS ±1 digit max.

Transfer output accuracy           ±0.3% FS max.

Remote SP Input Type               ±0.2% FS ±1 digit max.

Influence of temperature *2        Thermocouple input (R, S, B, W, PL II): (±1% of indication value or ±10°C, whichever is greater) ±1 digit

                                   max.

                                   Other thermocouple input: (±1% of indication value or ±4°C, whichever is greater) ±1 digit max. *3

                                   Platinum resistance thermometer: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max.

Influence of voltage *2            Analog input: ±1%FS ±1 digit max.

                                   CT input: ±5% FS ±1 digit max.

                                   Remote SP   input: ±1% FS ±1 digit max.

Input sampling period              50ms

Hysteresis                         Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or°F)

                                   Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

Proportional band (P)              Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                   Analog input: 0.1 to 999.9% FS (in units of 0.1% FS)

                                   Standard, heating/cooling, or Position-proportional (Close): 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in

Integral time (I)                  units of 0.1 s)

                                   Position-proportional (Floating): 1 to 9999 s (in units of 1 s), 0.1 to 999.9 s (in units of 0.1 s)*4

Derivative time (D)                0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Proportional band (P) for cooling  Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                   Analog input: 0.1 to 999.9% FS (in units of 0.1% FS)

Integral time (I) for cooling      0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D) for cooling    0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Control period                     0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)

Manual reset value                 0.0 to 100.0% (in units of 0.1%)

Alarm setting range                -1999 to 9999 (decimal point position depends on input type)

Influence of signal source resis-  Thermocouple: 0.1°C/Ω max. (100 Ω max.)

tance                              Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.)

Insulation resistance              20 MΩ min. (at 500 VDC)

Dielectric strength                3,000 VAC, 50/60 Hz for 1 min between terminals of different charge

Vibration   Malfunction            10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions

            Resistance             10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions

Shock       Malfunction            100 m/s2, 3 times each in X, Y, and Z directions

            Resistance             300 m/s2, 3 times each in X, Y, and Z directions

Weight                    E5EC     Controller: Approx. 210 g, Adapter: Approx. 4 g × 2

                          E5AC     Controller: Approx. 250 g, Adapter: Approx. 4 g × 2

Degree of protection               Front panel: IP66, Rear case: IP20, Terminals: IP00

Memory protection                  Non-volatile memory (number of writes: 1,000,000 times)

Setup Tool                         CX-Thermo version 4.5 or higher

                                   E5EC/E5AC top panel:     An E58-CIFQ2 USB-Serial Conversion Cable is used to connect to a USB port

Setup Tool port                                             on the computer.*5

                                   E5EC/E5AC front panel:   An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion

                                                            Cable are used together to connect to a USB port on the computer.*5

Standards   Approved standards     UL 61010-1, Korean Radio Waves Act (Act 10564)

            Conformed standards    EN 61010-1 (IEC 61010-1): Pollution Degree 2, overvoltage category II, Lloyd's standards *6

                                   EMI                                                                       EN61326

                                   Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A

                                   Noise Terminal Voltage:                                                   EN 55011 Group 1, class A

                                   EMS:                                                                      EN 61326

EMC                                ESD Immunity:                                                             EN 61000-4-2

                                   Electromagnetic Field Immunity:                                           EN 61000-4-3

                                   Burst Noise Immunity:                                                     EN 61000-4-4

                                   Conducted Disturbance Immunity:                                           EN 61000-4-6

                                   Surge Immunity:                                                           EN 61000-4-5

                                   Voltage Dip/Interrupting Immunity:                                        EN 61000-4-11

*1  The indication accuracy of K thermocouples in the -200 to 1,300°C range, T and N thermocouples at a temperature of -100°C max., and U and L thermocouples

    at any temperatures is ±2°C ±1 digit max. The indication accuracy of the B thermocouple at a temperature of 400°C max.

    is not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800°C is ±3°C max. The indication accuracy of the R and S thermocouples

    at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W thermocouples is (±0.3% of PV or ±3°C, whichever is greater) ±1 digit max. The

    indication accuracy of PL II thermocouples is (±0.3% of PV or ±2°C, whichever is greater) ±1 digit max.

*2  Ambient temperature: -10°C to 23°C to 55°C, Voltage range: -15% to 10% of rated voltage

*3  K thermocouple at -100°C max.: ±10°C max.

*4  The unit is determined by the setting of the Integral/Derivative Time Unit parameter.

*5  External communications (RS-485) and USB-serial conversion cable communications can be used at the same time.

*6  Refer to information on maritime standards in Shipping Standards on page 106 for compliance with Lloyd's Standards.

                                                                                                                                                                      41
E5EC/E5AC

USB-Serial Conversion Cable                                                                                                    When Digital Temperature Controllers are con-

                                                                                                                               nected, set points and RUN/STOP commands

    Applicable OS           Windows XP/Vista/7/8                                                                               can be sent from the Digital Temperature Control-

    Applicable software     CX-Thermo version 4.5 or higher                             Component                              ler that is set as the master to the Digital Temper-

                                                                                        Communications*1                       ature Controllers that are set as slaves.

    Applicable models       E5@C-T Series, E5@C Series, and E5CB Series                                                        Slope and offsets can be set for the set point.

    USB interface standard  Conforms to USB Specification 2.0.                                                                 Number of connected Digital Temperature Con-

                                                                                                                               trollers: 32 max. (including master)

    DTE speed               38,400 bps                                                                                         When Digital Temperature Controllers are con-

    Connector               Computer: USB (type A plug)                                                                        nected, the parameters can be copied from the

    specifications          Digital Temperature Controller:                             Copying*2                              Digital Temperature Controller that is set as the

                            Special serial connector                                                                           master to the Digital Temperature Controllers that

    Power supply            Bus power (Supplied from USB host controller.)*                                                    are set as slaves.

    Power supply voltage    5 VDC                                                       MELSEC is a registered trademark of Mitsubishi Electric Corporation.

    Current consumption     450 mA max.                                                 KEYENCE is a registered trademark of Keyence Corporation.

                            4.7±0.2 VDC                                                 *1                       A Temperature Controller with version 1.1 or higher is required.

    Output voltage          (Supplied from USB-Serial Conversion Cable to                                        A Temperature Controller with version 2.1 or higher is required for

                            the Digital Temperature Controller.)                                                 the FX Series or the KV Series.

                            250 mA max.                                                 *2                       Both the programless communications and the component

    Output current          (Supplied from USB-Serial Conversion Cable to                                        communications support the copying.

                            the Digital Temperature Controller.)

    Ambient operating       0 to 55°C (with no condensation or icing)                   Current Transformer (Order Separately)

    temperature                                                                         Ratings

    Ambient operating       10% to 80%

    humidity                                                                            Dielectric strength                    1,000 VAC for 1 min

    Storage temperature     -20 to 60°C (with no condensation or icing)                 Vibration resistance                   50 Hz, 98 m/s2

    Storage humidity        10% to 80%                                                                                         E54-CT1: Approx. 11.5 g,

    Altitude                2,000 m max.                                                Weight                                 E54-CT3: Approx. 50 g

    Weight                  Approx. 120 g                                               Accessories                            Armatures (2)

Windows is a registered trademark of Microsoft Corporation in the                       (E54-CT3 only)                         Plugs (2)

United States and or other countries.

*   Use a high-power port for the USB port.                                             Heater Burnout Alarms and SSR Failure

Note: A driver must be installed on the computer. Refer to the

          Instruction Manual included with the Cable for the installation               Alarms

          procedure.

                                                                                                                               Models with detection for singlephase

Communications Specifications                                                           CT input (for heater                   heaters: One input

                                                                                        current detection)                     Models with detection for singlephase or

    Transmission line       RS-485: Multidrop                                                                                  three-phase heaters: Two inputs

    connection method                                                                   Maximum heater

    Communications          RS-485 (two-wire, half duplex)                              current                                50 A AC

    Synchronization         Start-stop synchronization                                  Input current indica-

    method                                                                              tion accuracy                          ±5% FS ±1 digit max.

    Protocol                CompoWay/F, or Modbus

    Baud rate*              9600, 19200, 38400, or 57600 bps                            Heater burnout                         0.1 to 49.9 A (in units of 0.1 A)

    Transmission                                                                        alarm setting range                    Minimum detection ON time: 100 ms *3

    code                    ASCII                                                       *1

    Data bit length*        7 or 8 bits                                                 SSR failure alarm                      0.1 to 49.9 A (in units of 0.1 A)

    Stop bit length*        1 or 2 bits                                                 setting range *2                       Minimum detection OFF time: 100 ms *4

                            Vertical parity (none, even, odd)                           *1.                      For heater burnout alarms, the heater current will be measured when the

    Error detection         Block check character (BCC) with                                                     control output is ON, and the output will turn ON if the heater current is

                            CompoWay/F or CRC-16 Modbus                                                          lower than the set value (i.e., heater burnout detection current value).

    Flow control            None                                                        *2.                      For SSR failure alarms, the heater current will be measured when the

    Interface               RS-485                                                                               control output is OFF, and the output will turn ON if the heater current is

                                                                                                                 higher than the set value (i.e., SSR failure detection current value).

    Retry function          None                                                        *3.                      The value is 30 ms for a control period of 0.1 s or 0.2 s.

    Communications buffer   217 bytes                                                   *4.                      The value is 35 ms for a control period of 0.1 s or 0.2 s.

    Communications          0 to 99 ms

    response wait time      Default: 20 ms                                              Electrical Life Expectancy Curve for

*   The baud rate, data bit length, stop bit length, and vertical parity  can  be  in-  Relays (Reference Values)

    dividually set using the Communications Setting Level.

Communications Functions                                                                Life (× 104 operations)  500

                                                                                                                 300

                            You can use the memory in the PLC to read and

                            write E5@C parameters, start and stop operation,                                                   E5EC/E5AC

                            etc. The E5@C automatically performs communi-                                        100           250 VAC, 30 VDC

                            cations with PLCs. No communications program-                                                      (resistive load)

                            ming is required.                                                                    50            cosφ = 1

                            Number of connected Digital Temperature Con-                                         30

                            trollers: 32 max. (Up to 16 for the FX Series)

    Programless             Applicable PLCs

    communications*1        OMRON PLCs                                                                           10

                                  CS Series, CJ Series, or CP Series

                            Mitsubishi Electric PLCs                                                             5

                                  MELSEC Q Series, L Series, or FX Series                                        3

                                  (compatible with the FX2 or FX3 (excluding

                                  the FX1S))

                            KEYENCE PLCs                                                                         1

                                  KEYENCE KV Series                                                                   0  1  2  3         4        5   6

                                                                                                                                  Switching current (A)

42
                                                                                                                                                                                                                       E5EC/E5AC

External Connections

E5EC/E5AC

                       E5EC- @ @                    4     @     5     M - @@@                    E5AC- @ @             4         @      5   M - @@@

                                          (1)      (2) (3) (4) (5)             (6)                             (1)     (2) (3) (4) (5)                       (6)                     The E5EC is set for a K-type thermocouple (input

                                                                ↑                                                                       ↑                                            type = 5) by default. An input error (s.err) will occur

                                                       Terminal type                                                      Terminal type                                              if the input type setting does not agree with the

                                                                                                                                                                                     temperature sensor. Check the input type.

   Control output 1                       Control output 2                     Auxiliary outputs 1, 2, 3, 4            (6) Options

Relay output                          Relay output                             Relay output                                      004                               005                        009                                  010

250 VAC, 5 A                          250 VAC, 5 A                             Models with 4 auxiliary                           Communications                    4 event    inputs          Communications, 2 event              4 event inputs

(resistive load)                      (resistive load)                         outputs: 250 VAC, 2 A                             and 2 event inputs                                           inputs, and 2 CT inputs              and 1 CT input

Voltage output                        Voltage output                           (resistive load)                                     B(+)       13               -               13                 B(+)     13                  -

(for driving SSR)                     (for driving SSR)                                                                          RS-485                                                       RS-485                                         13

12 VDC, 40 mA                         12 VDC, 21 mA                                                                                   A(-)     14                     +  EV3    14                 A(-)     14                     +EV3      14

When There Is a                       Linear current output                                                                                    15               +               15                          15              +                15

Control Output 2:                     0 to 20 mA DC                                                                              -                              -  EV4                        -                                 EV4
                                                                                                                                                                                                                                -
21 mA                                                                                                                                          16                               16                          16                               16

                                      4 to 20 mA DC                                                                                 +          17                     +         17                 +        17                     +         17

Linear current output                 Load: 500 Ω max.                                                                           +     EV1     18               +        EV1    18            +    EV1      18              +       EV1      18

0 to 20 mA DC                                                                                                                    EV2                               EV2                        EV2                               EV2

4 to 20 mA DC                                                                                                                                  19                               19                          19                     CT1       19

Load: 500 Ω max.                                                                                                                               20                               20            CT1           20                               20

                                                                                                                                                                                                      COM

                                                                                                                                               21                               21            CT2           21                               21

(1) Control output

    RX                        QX                          CX                                                                                       011

Models with            Models with 1                Models with 1                                                                                  6 event Inputs, 1 CT input,

1 Relay Output         Voltage Output               Linear Current Output                                                                          transfer output, and remote SP input

                       (for Driving SSR)

    3           OUT1       3          +   OUT1            3        +  OUT1          (3) Input Power        Supply                                                                       -          13

    4           R          4          -   Q                        -  C                                                                                                                    +       14

                                                          4                         100 to 240 VAC           24 VAC/DC                                                                +    EV3

    5                      5                              5                                                                                                                             EV4        15

                                                                                                    1                  1                                        -             28        -          16

    6                      6                              6                                                            2                                              +       29           +       17

                                                                                                    2                                                         +       EV5               +  EV1

   QQ                                     QR                                                                   (no polarity)                                    EV6           30        EV2        18

Models with 2 Voltage         Models with Voltage Output (for                                                                                                      +          31                   19

Outputs (for Driving SSR)     Driving SSR) and Relay Output                                                                                        Transfer V            +    32         CT1       20

                OUT1                            OUT1                                                                                               output                I

    3        +  Q                 3          +  Q                                   1               25     13                                                      -          33                   21

    4        -                    4          -                                      2               26     14                                                      +     +    34

    5                             5                                                 3               27     15                                      Remote V              mA   35

             +  Q                               R                                                                                                  SP input                   36
                                                                                                                                                                   -
    6        -                    6                                                 4               28     16
                OUT2                            OUT2

RR                 PR                     CC                                        5               29     17                                      013                                                 014

Models with 2      Models with 2          Models with 2                             6               30     18                                      6 event Inputs, transfer                            Communications, 4 event Inputs,

Relay Outputs      Position-proportional  Linear Current                            7               31     19                                      output, and remote SP input                         transfer output, and remote SP input

                   Relay Output   Open    Outputs                                   8               32     20                                                                                                                            B(+)

3            OUT1   3                        3               OUT1                                                                                                                 -           13                                        RS-485     13

             R                    R                    +     C                      9               33     21                                                                        +        14                                                   14
                                                       -
4                   4                        4                                      10              34     22                                                                   +     EV3                                                A(-)
                                                                                                                                                                                              15                                                   15
                                                                                                                                                                                    EV4
5                   5                        5         +                            11              35     23                                                            28       -                           -             28        -            16
                                                             C                                                                                         -                                      16
             R                    R                    -
6                   6                        6                                      12              36     24                                                +                       +                              +       29           +
             OUT2                 Close                      OUT2                                                                                                        29                   17                       EV5                         17
                                                                                                                                                              EV5                     EV1                                                   EV1
CQ                                                                                                                                                    +                           +                           +             30        +            18
                                                                                                                                                                         30                   18
                                                                                                                                                       EV6                          EV2                       EV6                       EV2
Models with 2 Outputs: Linear Current Output
                                                                                                                                                          +              31                   19                 +          31                     19
                                                                                                                                                                   +                                                   +
and Voltage (for Driving SSR)                                                                                                               Transfer V                                                Transfer      V       32                     20
                                                                                                                                                                         32                   20
                                                                                                                                            output                 I                                  output           I
                OUT1
    3        +                   (2)  Auxiliary Outputs                                          Potentiometer         Input                              -              33                   21                 -          33                     21
                C
             -                                                                                                                                            +              34                                      +          34
    4                                     Auxiliary outputs        1, 2, 3, 4                                  19                                                  +                                                   +
                                                                                                        O                                   Remote V                                                  Remote        V
                                                                                                                                                                         35                                                 35
    5                                           7                                                              20                                                  mA                                 SP input-        mA
             +                                                                                          W                                   SP inpu-t
                Q                                   Auxiliary      output 4                                                                                              36                                                 36
             -                                  8                                                              21
    6           OUT2                                                                                    C
                                                    Auxiliary      output 3
                                                9
                                                                                                                                                              Note:         1.    The application of the terminals depends on

                                                10  Auxiliary      output 2                                                                                                       the model.

                                                11                                  (5) Sensor (Temperature/Analog) Input                                                   2.    Do not wire the terminals that are shown with

                                                12  Auxiliary      output 1                         TC             Pt               I              V                              a gray background.

                                                                                                    22       A     22         +     22             22                       3.    When complying with EMC standards, the

                                                                                                 -  23         B   23  mA           23         -   23                             cable that connects the sensor must be 30 m

                                                                                                    24         B 24           -     24      V      24                             or less. If the cable length exceeds 30 m,

                                                                                                 +                                             +                                  compliance with EMC standards will not be

                                                                                                                                                                                  possible.

                                                                                                                                                                            4.    Connect M3 crimped terminals.

Isolation/Insulation Block Diagrams

Models with 4 Auxiliary Outputs

                       Sensor input, CT inputs, potentiometer input, and remote SP input

                                          Communications and event inputs

                                          Voltage output (for driving SSR),

        Power                         linear current output, and transfer output

        Supply

                                                          Relay output

                                                   Auxiliary outputs 1, 2

                                                   Auxiliary outputs 3, 4

                       : Reinforced insulation

                       : Functional isolation

Note:   Auxiliary   outputs 1 to 2 and 3 to 4 are not insulated.

                                                                                                                                                                                                                                                       43
E5EC/E5AC

Nomenclature

E5EC

                                 Front panel

                                                                                No. 1 display

                                                                                PV or specified parameter                                             Top View of  E5EC

      Temperature unit

      Operation indicators                                                      No. 2 display

                                                                                SP or specified parameter value

                                                                                No. 3 display                                                                               Top-panel

    Front-panel Setup Tool port                                                 Manipulated value or other value                                                            Setup

                                                                                MUansieputhlaeteUd vaDlueKoeryosthtoersveatlue                                              Tool port

                                                                                the parameter.

                                                                                Use S Key to change the digit                   (default  setting).

                                                                                Use the M Key to change to another parameter.

    Press O Key once to go to Adjustment Level.

    Press O Key for at least 3 seconds to go to Initial Setting  Level.

E5AC

                                 Front Panel

                                                                                                                                                      Top          View of  E5AC

    Temperature unit                                                            No. 1 display

    Operation indicators                                                        PV or specified parameter

                                                                                No. 2 display

                                                                                SP or specified parameter value

    Front-panel Setup Tool port                                                 No. 3 display

                                                                                Manipulated value or other value

                                                                                Press the U or D Key to set                     the       parameter.                              Top-panel

                                                                                                                                                                                  Setup

                                                                                                                                                                                  Tool port

                                                                                Press the S Key to change the digit (default setting).

    Press the O Key once to go to the Adjustment Level.                         Press the M Key to change to another parameter.

    Press the O Key for at least 3 seconds to go to the Initial Setting Level.

44
                                                                                                                                                 E5EC/E5AC

Dimensions                                                                                                                                              (Unit: mm)

Controllers

E5EC

                                                                      4            (64)

                                                       48             1            60                     44

                                                                                                                                 The Setup Tool ports are on the front and top

                                                                                                                                 of the Digital Temperature Controller.

                                                                                                                                 It is used to connect the Temperature Con-

                                                                                                                                 troller to the computer to use the Setup Tool.

                                                                                                                                 The E58-CIFQ2 USB-Serial Conversion

                                                                                                                                 Cable is required to make the connection.

                                       96                                                            110                     91  Refer to the instructions that are provided

                                                                                                                                 with the USB-Serial Conversion Cable for the

                                                                                                                                 connection procedure.

                                                                                                                                 Note:  Do not leave the USB-Serial

                                                                                                                                        Conversion Cable connected when

                                                                                                                                        you use the Temperature Controller.

                                                       Waterproof

                                                       Packing (Accessory)         Mounting Adapter

                                                                                   (Accessory)

             Mounted Separately                 Group Mounted *

                                                (48 × number of units − 2.5)+10.0                    *    Selections for Control Outputs 1 and 2: QQ, QR, RR, CC, PR, or CQ

                       45+0.06                                                                            If you also specify 011, 013, or 014 for the option selection and use

                                                                                                          group mounting, the ambient temperature must be 45°C or less.

                                                                                                          If the ambient temperature is 55°C, maintain the following mounting

                                                                                                          spaces between Controllers.

                                                                      92+00.8

                                                                                                                             60 min.

                                                                                                                    45-00.6

             120 min.                           Group mounting does not

                                                allow waterproofing.

                                                                                                                                        92+00.8

                                       92-00.8

                                                                                                          120 min.

      •  Recommended panel thickness is 1 to 8 mm.

      •  Group mounting is not possible in the vertical direction. (Maintain the

         specified mounting space between Controllers.)

      •  To mount the Controller so that it is waterproof, insert the waterproof

         packing onto the Controller.

      •  When two or more Controllers are mounted, make sure that the

         surrounding temperature does not exceed the allowable operating

         temperature specified in the specifications.

                                                                                                                                                                                 45
E5EC/E5AC

E5AC                                                                                                     (64)

                                                                                                   4     60

                                                                    96 x 96                           1                             91 x 91

                                                                                                                     110                            91

                                                                              Waterproof

                                                                              Packing (Accessory)  Mounting Adapter

                                                                                                   (Accessory)

                                           The Setup Tool ports are on the front and top of the Digital Temperature Controller.

                                           It is used to connect the Temperature Controller to the computer to use the Setup Tool.

                                           The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection.

                                           Refer to the instructions that are provided with the USB-Serial Conversion Cable for the connection procedure.

                                           Note: Do not leave the USB-Serial Conversion Cable connected when you use the Temperature Controller.

              Mounted Separately           Group Mounted *

                                           (96 × number of units − 3.5)+10.0                          • Recommended panel thickness is 1 to 8 mm.

              92+00.8

                                                                                                      • Group mounting is not possible in the vertical direction. (Maintain the

                                                                                                      specified mounting space between Controllers.)

                                                                                                      • To mount the Controller so that it is waterproof, insert the waterproof

                                                                                                      packing onto the Controller.

                                                                              92+00.8                 • When two or more Controllers are mounted, make sure that the

                                                                                                      surrounding temperature does not exceed the allowable operating

                                                                                                      temperature specified in the specifications.

    120 min.                               Group mounting does not

                                           allow waterproofing.

                                  92+00.8

46
                                                                                                                                E5EC/E5AC

Accessories (Order Separately)

● USB-Serial Conversion Cable

E58-CIFQ2                                                                               (2110)

                                                        250                                                  263                      1510

                                                                              LED (RD)

                                         USB connector

                                         (type A plug)                                                                                        Serial connector

                                                                                        LED (PWR)

                                                                                        LED (SD)

● Conversion Cable

E58-CIFQ2-E

           Conversion Cable                     Connecting to        the  E58-CIFQ2     USB-Serial Conversion Cable

                                                                                                     (2110)

                         (1510)                                 250                                               263                       1510

                                                                          E58-CIFQ2     (Order Separately)                      Conversion Cable

Note: Always use this product together with     the E58-CIFQ2.

● Terminal Covers                                       ● Waterproof Packing

E53-COV24 (Three Covers provided.)                      Y92S-P9 (for DIN 48 × 96)

                                 2  3.8

                                                                                        The Waterproof Packing is provided with the Temperature

                                                                                        Controller.

                         10                                                             Order the Waterproof Packing separately if it becomes lost or

                                                                                        damaged.

                                                                                        The degree of protection when the Waterproof Packing is used

                                                                                        is IP66.

                                                                                        Also, keep the Port Cover on the front-panel Setup Tool port

                                                                                        of the E5EC/E5AC securely closed.

                     91                                                                 To maintain an IP66 degree of protection, the Waterproof

                                                                                        Packing and the Port Cover for the front-panel Setup Tool port

                                                                                        must be periodically replaced because they may deteriorate,

                                                                                        shrink, or harden depending on the operating environment.

                                                        Y92S-P10 (for DIN 96 × 96)      The replacement period will vary with the operating

                                                                                        environment.

                                                                                        Check the required period in the actual application.

                                                                                        Use 3 years or sooner as a guideline.

                                                                                        If a waterproof structure is not required, then the Waterproof

                                                                                        Packing does not need to be installed.

● Setup  Tool  Port  Cover   for    top  panel                            ● Mounting Adapter

Y92S-P7                                                                   Y92F-51 (Two Adapters              provided.)

                                         Order this Port Cover                                                           One pair is provided with the

                                         separately if the Port Cover on                                                 Controller.

                                         the front-panel Setup Tool port                                                 Order this Adapter

                                         is lost or damaged. The                                                         separately if it becomes lost

                                         Waterproof Packing must be                                                      or damaged.

                                         periodically replaced because

                                         it may deteriorate, shrink, or

                                         harden depending on the

                                         operating environment.

                                                                                                                                                                47
E5EC/E5AC

● Watertight Cover                                                                         ● Watertight Cover

Y92A-49N (48 × 96)                                                                         Y92A-96N (96 × 96)

                                                      21.9    (2)                                                                                                                                       21.9        (2)

                    131.7                                                                  131.7

                                 67.6                 28.9                                                                        115.6                                                                 28.9

● Current Transformers

E54-CT1                                                                                           Thru-current (Io) vs. Output Voltage (Eo)

                                                  21                         2.8                  (Reference Values)

                                                  15          5.8 dia.

                                                                                                  E54-CT1

                                                                                   7.5            Maximum continuous heater current:                                                                    50 A (50/60 Hz)

                                                                                                  Number of windings:                                                                                   400±2

                                       25      3                                                  Winding resistance:                                                                                   18±2 Ω

                                                              10.5                                                                Output voltage (Eo) V (r.m.s.)  100V          Frequency: 50 Hz

                                                  40                                                                                                                     10                       ∞                           Distortion

                                                              Two, 3.5 dia.                                                                                                                   1kΩ                             factor

                                                                                                                                                                                                                              10%

                                                                                                                                                                         1

                                           10                                                                                                                                                                             3%

                                                                                                                                                                                                                      1%

                                                  30                                                                                                              100mV

                                                                                                                                                                         10                                100Ω

E54-CT3

                                                                        2.36 dia.                                                                                        1                                 RL=10Ω

                                                  30

                                                              12 dia.

                                                                                        9                                                                         100μV

                                                                                                                                                                         10

                                                                                                                                                                             1      10     100mA        1         10          100  1,000A

                                       40  × 40                                                                                                                                                            Thru-current (Io) A (r.m.s.)

                                                                                                  Thru-current (Io) vs. Output Voltage (Eo)

                                                                                                  (Reference Values)

                                                            Two, M3 (depth: 4)                    E54-CT3

                                           15                                                     Maximum continuous heater current:                                                                    120 A (50/60 Hz)

                                                                                                  (Maximum continuous heater current for an OMRON Digital

                                                                                                  Temperature Controller is 50 A.)

                                                  30                                              Number of windings:                                                                                   400±2

                                                                                                  Winding resistance:                                                                                   8±0.8 Ω

E54-CT3 Accessories                                                                               Output voltage (Eo) V (r.m.s.)  100V

    • Armature                                    Connection  Example                                                                                                    Frequency: 50 Hz

                                                                                                                                                                                           ∞                                  Distortion

                                                                        Armature                                                                                  10                    1kΩ                                   factor

    Approx. 3 dia.                                    Plug                                                                                                                              500Ω                                  10%

                                                                                                                                                                                                                              3%

                                                                                                                                                                  1                                                      1%

                                                                                  Lead

                                                                                                                                  100mV

                                                                                                                                                                                                              100Ω

                                 18                                                                                                                               10                                       50Ω

    • Plug                                                                                                                                                                                                 RL=10Ω

                                                                                                                                                                  1

    Approx. 6 dia.                                                                                                                100μV

                           (22)                                                                                                                                   10  1         10  100mA            1        10         100  1,000A

                                                                                                                                                                                                        Thru-current (Io) A (r.m.s.)

48
MEMO

      49
    Digital Temperature Controller

    E5DC                       (22.5 mm Wide, and DIN Track-mounting Type)

The E5DC Mounts to DIN Track and Is Ideal

for Connections to HMIs and PLCs.

It provides the Same Easy Operation and

Advanced Performance as the Rest of the

E5@C Series.

    • A slim body at 85 × 22.5 mm (D × W) that fits into narrow control

    panels and mounts to DIN Track.

    • Removable terminal block for easy replacement to simplify maintenance.

    • High-speed sampling at 50 ms for applications with high-speed

    temperature increases.

    • Easy connections to a PLC with programless communications.

    • Set up the Controller without wiring the power supply by connecting

    to the computer with a Communications Conversion Cable (sold separately).           22.5 mm Wide, and

    Setup is easy with the CX-Thermo (sold separately).                                 DIN Track-mounting Type

    • Models are available with up to 2 auxiliary outputs and 1 event input to                     E5DC

    complete basic functions.                                                   Refer to your OMRON website for the most recent

    • A white PV display (height: 8.5 mm) is easy to read when setting up,      information on applicable safety standards.

    checking alarms, and making settings in a control panel.                        Refer to Safety Precautions on page 104.

Main  I/O Functions

      Sensor Input                                                     E5DC

      Universal input

      • Thermocouple

      • Pt                                                                      Dual displays: PV/SV           4-digit  displays

      • Analog current/voltage

            Indication Accuracy                                                 Control Output 1

            • Thermocouple input:                                               • Relay output

            ±0.3% of PV                                                         • Voltage output (for driving  SSR)

            • Pt input: ±0.2% of PV                                             • Linear current output

            • Analog input:

            ±0.2% of FS

                                                                                Auxiliary Outputs

            Sampling Period                                                     • None

            • 50 ms                                                             •2

      Event Inputs

      • None                         • PF (shift) Key

      •1                             • Temperature status display

      Serial Communications          • Simple programming

      • None                         • Independent heating and

                                     cooling PID control

      • RS-485                       • Changed parameter display

                                     • Display brightness setting

    This datasheet is provided as a guideline for selecting products.

    Be sure to refer to the following manuals for application precautions and other information required for operation before attempting

    to use the product.

    E5@C Digital Temperature Controllers User’s Manual (Cat. No. H174)

    E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)

50
                                                                                                                                                E5DC

Model Number Legend and Standard Models

Model Number Legend

●Models with Screw Terminals

E5DC-− @@−         − @ − @ − @ − M-@−@−@−(Example: E5DC-RX0ASM-015)
            A      BC       DE          F

                A             B         C           D              E         F

Model       Control      No. of         Power       Terminal     Input                                              Meaning

            output 1  auxiliary      supply         type         type        Options

                      outputs        voltage

E5DC                                                                                                22.5 mm wide and mounts to DIN Track

                                                                                      Control output 1                               Control output 2

            RX                                                                                      Relay output                          None

            QX                                                                                   Voltage output                           None

                                                                                                 (for driving SSR)

        *1  CX                                                                        Linear current output *1                            None

                      0                                                                                                  None

                      2                                                                                             2 (one common)

                                     A                                                                              100 to 240 VAC

                                     D                                                                              24 VAC/DC

                                               S                                      Screw terminals (Main Unit and Terminal Unit together)

                                               U                                                      Main Unit only (no Terminal Unit)

                                                              M                                                     Universal input

                                                                                      HB alarm and HS alarm                Communications       Event input

                                                                        *2   000                      ---                            ---               ---

                                                                        *3   002                      1                          RS-485                ---

                                                                        *4   015                      ---                        RS-485                ---

                                                                        *5   016                      ---                            ---               1

                                                                        *3   017                      1                              ---               1

*1  The control output can be used as a simple transfer output for the Digital Temperature Controllers manufactured in July 2014 or later.

*2  Option 000 can be selected only if two auxiliary outputs are selected.

*3  Options 002 and 017 can be selected only if the control output is a relay output or voltage output and two auxiliary outputs are selected.

*4  Option 015 cannot be selected if the control output is a relay output or voltage output and two auxiliary outputs are selected.

*5  Options 016 can be selected only if the control output is a linear current output and two auxiliary outputs are selected.

List of Models

                   No. of auxiliary                                Options                                          Model                  Model

Control output        outputs           HB alarm and HS       No.  of event  inputs   Communications       Power supply voltage           Power supply voltage

                                           alarm                                                           100 to 240 VAC                 24 VAC/DC

                         ---                                                          RS-485               E5DC-RX0ASM-015                E5DC-RX0DSM-015

                                               ---                                                         E5DC-RX0AUM-015                E5DC-RX0DUM-015

                                                                        ---           ---                  E5DC-RX2ASM-000                E5DC-RX2DSM-000

Relay output                                                                                               E5DC-RX2AUM-000                E5DC-RX2DUM-000

                         2                                                            RS-485               E5DC-RX2ASM-002                E5DC-RX2DSM-002

                                     Detection for single-                                                 E5DC-RX2AUM-002                E5DC-RX2DUM-002

                                     phase heater                       1             ---                  E5DC-RX2ASM-017                E5DC-RX2DSM-017

                                                                                                           E5DC-RX2AUM-017                E5DC-RX2DUM-017

                         ---                                                          RS-485               E5DC-QX0ASM-015                E5DC-QX0DSM-015

                                               ---                                                         E5DC-QX0AUM-015                E5DC-QX0DUM-015

                                                                        ---           ---                  E5DC-QX2ASM-000                E5DC-QX2DSM-000

Voltage output                                                                                             E5DC-QX2AUM-000                E5DC-QX2DUM-000

(for driving SSR)        2                                                            RS-485               E5DC-QX2ASM-002                E5DC-QX2DSM-002

                                     Detection for single-                                                 E5DC-QX2AUM-002                E5DC-QX2DUM-002

                                     phase heater                       1             ---                  E5DC-QX2ASM-017                E5DC-QX2DSM-017

                                                                                                           E5DC-QX2AUM-017                E5DC-QX2DUM-017

                         ---                                                          RS-485               E5DC-CX0ASM-015                E5DC-CX0DSM-015

                                                                                                           E5DC-CX0AUM-015                E5DC-CX0DUM-015

                                                                        ---           ---                  E5DC-CX2ASM-000                E5DC-CX2DSM-000

Linear current                                 ---                                                         E5DC-CX2AUM-000                E5DC-CX2DUM-000

output                   2                                                            RS-485               E5DC-CX2ASM-015                E5DC-CX2DSM-015

                                                                                                           E5DC-CX2AUM-015                E5DC-CX2DUM-015

                                                                        1             ---                  E5DC-CX2ASM-016                E5DC-CX2DSM-016

                                                                                                           E5DC-CX2AUM-016                E5DC-CX2DUM-016

Heating and Cooling Control

●Using Heating and Cooling Control

A Control Output Assignment                                                           B Control

An auxiliary output is used as the cooling control output.                            If PID control is used, you can set PID control separately for heating

                                                                                      and cooling.

                                                                                      This allows you to handle control systems with different heating and

                                                                                      cooling response characteristics.

                                                                                                                                                                51
E5DC

Optional Products (Order Separately)

Terminal Unit                                                      End Plate

               Model                                                            Model

            E5DC-SCT1S                                                          PFP-M

USB-Serial Conversion Cable                                        Spacer

               Model                                                            Model

            E58-CIFQ2                                                           PFP-S

Communications Conversion Cable                                    DIN Tracks

               Model                                                            Model

            E58-CIFQ2-E                                                         PFP-100N

Note: Always use this product together with the E58-CIFQ2.                      PFP-50N

    This Cable is used to connect to the front-panel Setup   Tool

    port.                                                          Unit Labels

Current Transformers (CTs)                                                      Model

    Hole diameter            Model                                              Y92S-L2

    5.8 mm                   E54-CT1

    12.0 mm                  E54-CT3                               End Cover

                                                                                Model

Mounting Adapter                                                                Y92F-54

               Model

           Y92F-53 (2pcs)

Short Bars

               Model

           Y92S-P11 (4 pcs)

CX-Thermo Support Software

               Model

            EST2-2C-MV4

Note: CX-Thermo version 4.6 or higher is required for the E5DC.

    For the system requirements for the CX-Thermo, refer to

    information on the EST2-2C-MV4 on the OMRON website

    (www.ia.omron.com).

52
                                                                                                                                      E5DC

Specifications

Ratings

Power supply voltage               A in model number: 100 to 240 VAC, 50/60 Hz

                                   D in model number: 24 VAC, 50/60 Hz; 24 VDC

Operating voltage range            85% to 110% of rated supply voltage

Power consumption                  4.9 VA max. at 100 to 240 VAC, and 2.8 VA max. at 24 VDC or 1.5 W max. at 24 VDC

                                   Temperature input

                                   Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II

                                   Platinum resistance thermometer: Pt100 or JPt100

Sensor input                       Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C

                                   Analog input

                                   Current input: 4 to 20 mA or 0 to 20 mA

                                   Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

Input impedance                    Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB/

                                   THB.)

Control method                     ON/OFF control or 2-PID control (with auto-tuning)

           Relay output            SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5

Control                            V, 10 mA (reference value)

output     Voltage output          Output voltage 12 VDC ±20% (PNP), max. Load current: 21 mA, with short-circuit protection circuit

           (for driving SSR)

           Linear current output   4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: Approx. 10,000

Auxiliary  Number of outputs       2 (depends on model)

output     Output specifications   SPST-NO relay outputs: 250 VAC, 2 A (resistive load),

                                   Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value)

           Number of inputs        1 (depends on model)

Event      External contact input  Contact input ON: 1 kΩ max., OFF: 100 kΩ min.

input      specifications          Non-contact input ON: Residual voltage 1.5 V max.; OFF: Leakage current 0.1 mA max.

                                   Current flow: approx. 7 mA per contact

Setting method                     Digital setting using front panel keys

Indication method                  11-segment digital displays and individual indicators

                                   Character height: PV: 8.5 mm, SV: 8.0 mm

Multi SP                           Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or

                                   serial communications.*1

Bank switching                     None

                                   Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burn-

                                   out (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self

Other functions                    tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change

                                   rate limit, logic operations, temperature status display, simple programming, moving average of input val-

                                   ue, display brightness setting, simple transfer output,*2 and work bit message*2

Ambient operating temperature      −10 to 55°C (with no condensation or icing), For 3-year warranty: −10 to 50°C with standard mounting (with

                                   no condensation or icing)

Ambient operating humidity         25% to 85%

Storage temperature                −25 to 65°C (with no condensation or icing)

Altitude                           2,000 m max.

Recommended fuse                   T2A, 250 VAC, time-lag, low-breaking capacity

Installation environment           Installation Category II, Pollution Degree 2 (IEC 61010-1 compliant)

*1  Only two set points are selectable for event inputs.

*2  Usage is possible for the Digital Temperature Controllers manufactured in July 2014 or later.

                                                                                                                                                53
E5DC

Input Ranges

●Thermocouple/Platinum Resistance Thermometer (Universal inputs)

    Sensor                                   Platinum resistance                                                                 Thermocouple                                                Infrared temperature

    type                                      thermometer                                                                                                                                           sensor

    Sensor

    specifica-                                Pt100            JPt100             K               J               T         E      L           U         N     R     S     B     W     PLII  10 to  60 to  115 to  140 to

                                                                                                                                                                                             70°C   120°C  165°C   260°C

                            tion

                                  2300                                                                                                                                           2300

                                  1800                                                                                                                                     1800

                                  1700                                                                                                                         1700  1700

                                  1600

    Temperature range (°C)        1500

                                  1400                                      1300                                                                         1300                          1300

                                  1300

                                  1200

                                  1100

                                  1000  850                                                 850                                    850

                                  900

                                  800

                                  700                                                                                       600

                                  600         500.0          500.0                   500.0

                                  500                                                                400.0  400      400.0               400      400.0

                                  400                                                                                                                                                                              260

                                  300                                                                                                                                                               120    165

                                  200                 100.0          100.0                                                                                                                   90

                                  100                                                                                                                                      100

                                  -100                0.0            0.0                                                                                       0     0           0     0     0      0      0       0

                                  -200                                               -20.0  -100     -20.0                         -100

                                        -200  -199.9         -199.9         -200                            -200  -199.9    -200         -200  -199.9    -200

    Set value                           0     1       2        3     4      5        6      7         8     9        10     11     12    13       14     15    16    17    18    19    20    21     22     23      24

                            Shaded settings are the default settings.

The applicable standards for the input types are as follows:

K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 60584-1                                                 JPt100: JIS C 1604-1989, JIS C 1606-1989

L: Fe-CuNi, DIN 43710-1985                                                                           Pt100: JIS C 1604-1997, IEC 60751

U: Cu-CuNi, DIN 43710-1985                                                                           PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)

W: W5Re/W26Re, ASTM E988-1990

●Analog input

                            Input type                         Current                                      Voltage

    Input specification                               4 to 20 mA     0 to 20 mA             1 to 5 V        0 to 5 V        0 to 10 V

                                                      Usable in the following ranges by scaling:

    Setting range                                     -1999 to 9999, -199.9 to 999.9,

                                                      -19.99 to 99.99 or -1.999 to 9.999

    Set value                                              25               26              27              28                 29

54
                                                                                                                                                 E5DC

Alarm Types

Each alarm can be independently set to one of the following 17 alarm types. The default is 2: Upper limit. (See note.)

Auxiliary outputs are allocated to alarms. ON delays and OFF delays (0 to 999 s) can also be specified.

Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not

    displayed.

    To use alarm 1, set the output assignment to alarm 1.

Set                                                Alarm output operation

value           Alarm type             When alarm value X           When alarm value X                             Description of function

                                                is positive              is negative

0          Alarm function OFF                                Output OFF                       No alarm

                                                                                              Set the upward deviation in the set point for the alarm upper

                                           ON      L     H                                    limit (H) and the lower deviation in the set point for the alarm

1          Upper- and lower-limit *1       OFF               PV     *2                        lower limit (L). The alarm is ON when the PV is outside this

                                                   SP

                                                                                              deviation range.

2                                                        X          ON        X               Set the upward deviation in the set point by setting the alarm

           Upper-limit                     ON                                                 value (X). The alarm is ON when the PV is higher than the

(default)                                  OFF     SP        PV     OFF        SP         PV

                                                                                              SP by the deviation or more.

                                           ON      X                ON              X         Set the downward deviation in the set point by setting the

3          Lower-limit                     OFF               PV     OFF                   PV  alarm value (X). The alarm is ON when the PV is lower than

                                                   SP                          SP             the SP by the deviation or more.

                                                                                              Set the upward deviation in the set point for the alarm upper

           Upper- and lower-limit          ON      L     H                                    limit (H) and the lower deviation in the set point for the alarm

4          range *1                        OFF               PV     *3                        lower limit (L). The alarm is ON when the PV is inside this de-

                                                   SP

                                                                                              viation range.

           Upper- and lower-limit          ON      L     H                                    A standby sequence is added to the upper- and lower-limit

5          with standby sequence *1        OFF               PV     *4                        alarm (1). *6

                                       *5          SP

           Upper-limit with standby        ON            X          ON        X

6          sequence                        OFF               PV     OFF                   PV  A standby sequence is added to the upper-limit alarm (2). *6

                                                   SP                          SP

           Lower-limit with standby        ON      X                ON              X

7          sequence                        OFF               PV     OFF                   PV  A standby sequence is added to the lower-limit alarm (3). *6

                                                   SP                          SP

           Absolute-value upper-lim-       ON         X             ON           X            The alarm will turn ON if the process value is larger than the

8          it                              OFF               PV     OFF                   PV  alarm value (X) regardless of the set point.

                                                0                                      0

                                           ON         X             ON           X            The alarm will turn ON if the process value is smaller than the

9          Absolute-value lower-limit      OFF               PV     OFF                   PV  alarm value (X) regardless of the set point.

                                                0                                      0

           Absolute-value upper-lim-       ON         X             ON           X            A standby sequence is added to the absolute-value upper-

10         it with standby sequence        OFF               PV     OFF                   PV  limit alarm (8). *6

                                                0                                      0

           Absolute-value lower-limit      ON         X             ON           X            A standby sequence is added to the absolute-value lower-

11         with standby sequence           OFF               PV     OFF                   PV  limit alarm (9). *6

                                                0                                      0

12         LBA (alarm 1 type only)                               -                            *7

13         PV change rate alarm                                  -                            *8

           SP absolute-value               ON         X             ON           X            This alarm type turns ON the alarm when the set point (SP)

14         upper-limit alarm               OFF               SP     OFF                   SP  is higher than the alarm value (X).

                                                0                                      0

           SP absolute-value               ON         X             ON           X            This alarm type turns ON the alarm when the set point (SP)

15         lower-limit alarm               OFF               SP     OFF                   SP  is lower than the alarm value (X).

                                                0                                      0

                                       Standard Control             Standard Control

                                           ON         X             ON           X

                                           OFF  0            MV     OFF                   MV

           MV absolute-value                                                           0      This alarm type turns ON the alarm when the manipulated

16         upper-limit alarm *9        Heating/Cooling              Heating/Cooling           variable (MV) is higher than the alarm value (X).

                                       Control (Heating MV)         Control (Heating MV)

                                           ON         X

                                           OFF  0            MV     Always ON

                                       Standard Control             Standard  Control

                                           ON         X             ON           X

                                           OFF  0            MV     OFF                0  MV

17         MV absolute-value           Heating/Cooling                                        This alarm type turns ON the alarm when the manipulated

           lower-limit alarm *9        Control (Cooling MV)         Heating/Cooling           variable (MV) is lower than the alarm value (X).

                                                                    Control (Cooling MV)

                                           ON         X

                                           OFF  0            MV     Always ON

                                                                                                                                                                55
E5DC

*1  With set values 1, 4, and 5, the upper- and lower-limit values can      *4  Set value: 5, Upper- and lower-limit with standby sequence

    be set independently for each alarm type, and are expressed as              For Upper- and Lower-Limit Alarm Described Above at *2

    “L” and “H.”                                                                •  In cases 1 and 2 above, the alarm is always OFF if the upper-

*2  Set value: 1, Upper- and lower-limit alarm                                     and lower-limit hysteresis overlaps.

    Case 1             Case 2     Case 3 (Always OFF)                           •  In case 3, the alarm is always OFF.

                                                                 H<0, L<0   *5  Set value: 5, Upper- and lower-limit alarm with standby sequence

            L  H  SP   SP L    H     H               SP    L                    The alarm is always OFF if upper- and lower-limit hysteresis

            H<0, L>0   H>0, L<0                                  H<0, L>0       overlaps.

            |H| < |L|  |H| > |L|  H             L SP             |H| ≥ |L|  *6  Refer to the E5@C Digital Temperature Controllers User’s Manual

                                                                 H>0, L<0       (Cat. No. H174) for information on the operation of the standby

                                                     SP H     L  |H| ≤ |L|      sequence.

*3  Set value: 4,      Upper- and lower-limit range                         *7  Refer to the E5@C Digital Temperature Controllers User’s Manual

    Case 1             Case 2     Case 3 (Always ON)                            (Cat. No. H174) for information on the LBA.

                                                                 H<0, L<0   *8  Refer to the E5@C Digital Temperature Controllers User’s Manual

    L          H  SP   SP L    H     H               SP    L                    (Cat. No. H174) for information on the PV change rate alarm.

    H<0, L>0           H>0, L<0                                  H<0, L>0   *9  When heating/cooling control is performed, the MV absolute-

    |H| < |L|          |H| > |L|  H             L SP             |H| ≥ |L|      value upper-limit alarm functions only for the heating operation

                                                                 H>0, L<0       and the MV absolute-value lower-limit alarm functions only for the

                                                     SP H     L  |H| ≤ |L|      cooling operation.

56
                                                                                                                                        E5DC

Characteristics

Indication accuracy                 Thermocouple:    (±0.3 % of indication value or ±1°C, whichever is greater) ±1 digit max.*1

(when mounted individually, ambi-   Platinum resistance thermometer: (±0.2 % of indication value or ±0.8°C, whichever is greater) ±1 digit max.

ent temperature of 23°C)            Analog input:    ±0.2% FS ±1 digit max.

                                    CT input:        ±5% FS ±1 digit max.

Simple transfer output accuracy     ±0.3% FS max.*2

Influence of temperature       *3   Thermocouple input (R, S, B, W, PL II): (±1% of indication value or ±10°C, whichever is greater) ±1 digit

                                    max.

                                    Other thermocouple input: (±1% of indication value or ±4°C, whichever is greater) ±1 digit max.     *4

Influence of voltage   *3           Platinum resistance thermometer: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max.

                                    Analog input: ±1% FS ±1 digit max.

                                    CT input: ±5% FS ±1 digit max.

Installation influence (E5DC only)  R, S, B, W, or PLII thermocouple: (±1% of PV or ±10°C, whichever is greater) ±1 digit max.

                                    Other thermocouple: (±1% of PV or ±4°C, whichever is greater) ±1 digit max. *4

Input sampling period               50 ms

Hysteresis                          Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                    Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

Proportional band (P)               Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                    Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I)                   0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5

Derivative time (D)                 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5

Proportional band (P) for cooling   Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                    Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I) for cooling       0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5

Derivative time (D) for cooling     0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5

Control period                      0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)

Manual reset value                  0.0% to 100.0% (in units of 0.1%)

Alarm setting range                 −1,999 to 9,999 (decimal point position depends on input type)

Influence of signal source resis-   Thermocouple: 0.1°C/Ω max. (100 Ω max.), Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.)

tance

Insulation resistance               20 MΩ min. (at 500 VDC)

Dielectric strength                 3,000 VAC, 50/60 Hz for 1 min between terminals of different charge

Vibration   Malfunction             10 to 55 Hz, 20 m/s2 for 10 min each in X, Y and Z directions

            Resistance              10 to 55 Hz, 20 m/s2 for 2 hr each in X, Y, and Z directions

Shock       Malfunction             100 m/s2, 3 times each in X, Y, and Z directions

            Resistance              300 m/s2, 3 times each in X, Y, and Z directions

Weight                              Main unit: Approx. 80 g, Terminal unit: Approx. 40 g

Degree of protection                Main unit: IP20, Terminal unit: IP00

Memory protection                   Non-volatile memory (number of writes: 1,000,000 times)

Setup Tool                          CX-Thermo version 4.6 or higher

                                    E5DC bottom panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect a USB port on the

Setup Tool port                     computer. *6

                                    E5DC front panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion Cable are

                                    used together to connect a USB port on the computer.*6

Standards   Approved standards      UL 61010-1, Korean Radio Waves Act (Act 10564)

            Conformed standards     EN 61010-1 (IEC 61010-1): Pollution Degree 2, overvoltage category II, Lloyd's standards *7

                                    EMI:                                                     EN61326

                                    Radiated Interference Electromagnetic Field Strength:    EN55011            Group  1, class A

                                    Noise Terminal Voltage:                                  EN55011            Group  1, class A

                                    EMS:                                                     EN61326

EMC                                 ESD Immunity:                                            EN61000-4-2

                                    Electromagnetic Field Immunity:                          EN61000-4-3

                                    Burst Noise Immunity:                                    EN61000-4-4

                                    Conducted Disturbance Immunity:                          EN61000-4-6

                                    Surge Immunity:                                          EN61000-4-5

                                    Voltage Dip/Interrupting Immunity:                       EN61000-4-11

*1  The indication accuracy of K thermocouples in the −200 to 1,300°C range, T and N thermocouples at a temperature of −100°C max., and U

    and L thermocouples at any temperature is ±2°C ±1 digit max. The indication accuracy of B thermocouples at a temperature of 400°C max. is

    not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800°C is ±3°C max.

    The indication accuracy of R and S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W

    thermocouples is (±0.3% of PV or ±3°C, whichever is greater) ±1 digit max.

    The indication accuracy of PLII thermocouples is (±0.3% of PV or ±2°C, whichever is greater) ±1 digit max.

*2  However, the precision between 0 and 4 mA for a 0 to 20 mA output is ±1% FS max.

*3  Ambient temperature: −10°C to 23°C to 55°C, Voltage range: −15% to 10% of rated voltage

*4  K thermocouple at −100°C max.: ±10°C max.

*5  The unit is determined by the setting of the Integral/Derivative Time Unit parameter.

*6  External serial communications (RS-485) and USB-Serial Conversion Cable communications can be used at the same time.

*7  Refer to information on maritime standards in Shipping Standards on page 106 for compliance with Lloyd's Standards.

                                                                                                                                                 57
E5DC

USB-Serial Conversion Cable                                                                                          When Digital Temperature Controllers are connected, set

                                                                                                                     points and RUN/STOP commands can be sent from the Digi-

    Applicable OS           Windows XP/Vista/7/8                                 Component                           tal Temperature Controller that is set as the master to the Dig-

    Applicable software     CX-Thermo version 4.6 or higher                      Communica-                          ital Temperature Controllers that are set as slaves.

                                                                                 tions*1                             Slope and offsets can be set for the set point.

    Applicable models       E5@C-T Series, E5@C Series, and E5CB Series                                              Number of connected Digital Temperature Controllers: 32

    USB interface standard  Conforms to USB Specification 2.0                                                        max. (including master)

    DTE speed               38,400 bps                                                                               When Digital Temperature Controllers are connected, the pa-

                                                                                 Copying*2                           rameters can be copied from the Digital Temperature Control-

    Connector               Computer: USB (Type A plug)                                                              ler that is set as the master to the Digital Temperature

    specifications          Digital Temperature Controller: Special serial con-                                      Controllers that are set as slaves.

                            nector                                               MELSEC is a registered trademark of Mitsubishi Electric Corporation.

    Power supply            Bus power (Supplied from the USB host controller) *  KEYENCE is a registered trademark of Keyence Corporation.

    Power supply voltage    5 VDC                                                *1                       A Temperature Controller with version 2.1 or higher is required for

    Current consumption     450 mA max.                                                                   the FX Series or the KV Series.

    Output voltage          4.7±0.2 VDC (Supplied from USB-Serial Conver-        *2                       Both the programless communications and the component

                            sion Cable to the Digital Temperature Controller.)                            communications support the copying.

    Output current          250 mA max. (Supplied from USB-Serial Conver-

                            sion Cable to the Digital Temperature Controller.)   Current Transformer (Order Separately)

    Ambient operating       0 to 55°C (with no condensation or icing)            Ratings

    temperature

    Ambient operating       10% to 80%                                           Dielectric strength                                   1,000 VAC for 1 min

    humidity                                                                                                                           50 Hz, 98 m/s2

    Storage temperature     −20 to 60°C (with no condensation or icing)          Vibration resistance

    Storage humidity        10% to 80%                                           Weight                                                E54-CT1: Approx. 11.5 g,

                                                                                                                                       E54-CT3: Approx. 50 g

    Altitude                2,000 m max.                                                                                               Armatures (2)

    Weight                  Approx. 120 g                                        Accessories (E54-CT3 only)                            Plugs (2)

Windows is a registered trademark of Microsoft Corporation in the

United States and or other countries.                                            Heater Burnout Alarms and SSR Failure

*   Use a high-power port for the USB port.                                      Alarms

Note: A driver must be installed on the computer. Refer to the

    Instruction Manual included with the Cable for the installation              CT input (for heater current                          Models with detection for single-phase heat-

    procedure.                                                                   detection)                                            ers: One input

                                                                                 Maximum heater current                                50 A AC

Communications Specifications                                                    Input current                                         ±5% FS ±1 digit max.

                                                                                 indication accuracy

    Transmission line connection    RS-485: Multidrop                            Heater burnout alarm                                  0.1 to 49.9 A (in units of 0.1 A)

    method                                                                       setting range *1                                      Minimum detection ON time: 100 ms *3

    Communications                  RS-485 (two-wire, half duplex)               SSR failure alarm setting                             0.1 to 49.9 A (in units of 0.1 A)

    Synchronization method          Start-stop synchronization                   range *2                                              Minimum detection OFF time: 100 ms *4

    Protocol                        CompoWay/F, or Modbus                        *1                       For heater burnout alarms, the heater current will be measured when the

    Baud rate*                      9,600, 19,200, 38,400, or 57,600 bps                                  control output is ON, and the output will turn ON if the heater current is

                                                                                                          lower than the set value (i.e., heater burnout detection current value).

    Transmission code               ASCII                                        *2                       For SSR failure alarms, the heater current will be measured when the

    Data bit length *               7 or 8 bits                                                           control output is OFF, and the output will turn ON if the heater current is

                                                                                                          higher than the set value (i.e., SSR failure detection current value).

    Stop bit length *               1 or 2 bits                                  *3                       The value is 30 ms for a control period of 0.1 s or 0.2 s.

                                    Vertical parity (none, even, odd)            *4                       The value is 35 ms for a control period of 0.1 s or 0.2 s.

    Error detection                 Block check character (BCC)                  Electrical Life Expectancy Curve for

                                    with CompoWay/F or

                                    CRC-16 with Modbus

    Flow control                    None                                         Control Output Relay (Reference Values)

    Interface                       RS-485                                       Life (× 104 operations)  500

    Retry function                  None                                                                  300

    Communications buffer           217 bytes

    Communications response         0 to 99 ms

    wait time                       Default: 20 ms                                                        100

* The baud rate, data bit length, stop bit length, and vertical parity can                                50

    be individually set using the Communications Setting Level.                                           30

Communications Functions

                     You can use the memory in the PLC to read and write E5@C                             10

                     parameters, start and stop operation, etc.

                     The E5@C automatically performs communications with                                  5

                     PLCs. No communications programming is required.                                             E5DC

                     Number of connected Digital Temperature Controllers: 32                              3       250 VAC, 30 VDC

    Programless      max. (Up to 16 for the FX Series)                                                            (resistive load)

    communica-       Applicable PLCs: OMRON PLCs                                                                  cosφ = 1

    tions *1                CS Series, CJ Series, or CP Series                                            1

                       Mitsubishi Electric PLCs                                                                0  1         2       3  4          5           6

                            MELSEC Q Series, L Series, or FX Series (compati-                                                          Switching current (A)

                            ble with the FX2 or FX3 (excluding the FX1S))

                       KEYENCE PLCs

                            KEYENCE KV Series

58
                                                                                                                                                                                    E5DC

External Connections

E5DC

       Control output                  Auxiliary outputs 1, 2                           The E5DC is set for a K-type thermocouple (input type = 5) by default.

Relay output                      Relay outputs                                         An input error (s.err) will occur if the input type setting does not agree

250 VAC, 3 A (resistive load)     250 VAC: 2 A (resistive load)                         with the temperature sensor. Check the input type.

Voltage output (for driving SSR)

12 VDC, 21 mA                                                                                  E5DC                 SM

Linear current output

0 to 20 mA DC                                                                                        Control output            Options

4 to 20 mA DC

Load: 500 Ω max.                  Input Power Supply                                           Control Output

                                  100 to 240 VAC      24 VAC/DC                                         RX                 QX                         CX

                                                1                 1                                  1 relay        1 voltage output               1 linear

                                                                                                     output         (for driving SSR)              current output

                                                2                 2                                  5        R         5      +            Q      5                +  C

                                                      (no polarity)                                  6                  6      -                   6                -

                                                                                     1  5  9

                                                                                     2  6  10                    Auxiliary Outputs

                                  Options                                                                           9

                       &nb