器件描述

controllers 1/4din TC voltage AC

参数

Manufacturer: Omron
Product Category: Controllers
RoHS: No
Brand: Omron Automation and Safety
Analog / Digital: Digital
Type: Digital Temperature Controller
Display Type: 11-Segment, 4 Digit
Supply Voltage: 100 VAC to 240 VAC
Mounting: Bracket
Control Method: ON/OFF, PID Control
Size: 96 mm x 96 mm
Features: Large white PV display that?s easier to read easy to use
Number of Inputs: 1
Number of Outputs: 4
Output Type: Control Output
Series: E5CC/E5EC/E5AC

E5AC-QX4A5M-000器件文档内容

New Product

Digital Temperature Controller

E5CC/E5EC/E5AC/E5DC

The new standard in temperature control is
higher in every respect
E5CC (48 48 mm) / E5EC (48 96 mm) / E5AC (96 96 mm)
E5DC (22.5 mm Wide, and DIN Track-mounting Type)

      Large White PV Display That's Easier to Read.
      Easy to Use, from Model Selection to Setup and Operation.
      A Complete Range of I/O Capacities, Functions, and Performance.
      Handles More Applications.
      New Models That Mount to DIN Track and Are Ideal for HMI/PLC Connections.

48 48 mm  48 96 mm                         22.5 mm Wide, and
    E5CC        E5EC    96 96 mm DIN Track-mounting Type

                        E5AC  E5DC

                                                                                 1
   Digital Temperature Controller

   E5CC (48 48 mm)

   Large White PV Display That's Easier to Read.
   Easy to Use, from Model Selection to
   Setup and Operation.
   A Complete Range of I/O Capacities,
   Functions, and Performance.
   Handles More Applications.

    The white PV display with a height of 15.2 mm improves visibility.

    High-speed sampling at 50 ms.                                       48 48 mm
    Models are available with up to 3 auxiliary outputs, up to 4 event      E5CC

   inputs, a transfer output, and a remote SP input to cover a wide      Refer to your OMRON website for the most recent
   range of applications.                                                information on applicable safety standards.

    Short body with depth of only 60 mm.

    Set up the Controller without wiring the power supply by            Refer to Safety Precautions on page 50.

   connecting to the computer with a Communications Conversion

   Cable (sold separately). Setup is easy with the CX-Thermo (sold

   separately).

    Easy connections to a PLC with programless communications. Use component communications to link

   Temperature Controllers to each other.

   Main I/O Functions

   Sensor Input                                         E5CC             Dual displays: PV/SV 4-digit displays
     Universal input
                                           PF (shift) Key              Control Output 1
    Thermocouple                           Temperature status display   Relay output
    Pt                                     Simple programming          Voltage output (for driving SSR)
    Analog current/voltage                Independent heating and      Linear current output

        Indication Accuracy                 cooling PID control          Control Output 2
         Thermocouple input:               Changed parameter display    None
         0.3% of PV                        Display brightness setting   Voltage output (for driving SSR)
         Pt input: 0.2% of PV
         Analog input:                                                  Auxiliary Outputs
        0.2% of FS                                                      3

        Sampling Period                                                   Transfer Output
         50 ms                                                            None
                                                                          1
   Event Inputs
    None
   2
   4

   Remote SP Input
    None
   1

   Serial Communications
    None
    RS-485

   This datasheet is provided as a guideline for selecting products.
   Be sure to refer to the following manuals for application precautions and other information required for operation before attempting
   to use the product.

      E5@C Digital Temperature Controllers User's Manual (Cat. No. H174)
      E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)

2
                                                                                                                                                E5CC

Model Number Legend and Standard Models

Model Number Legend

E5CC-@@ @ @ @ @ -@@@ (Example: E5CC-RX3A5M-000)

           -- - - - - ---
             A BC DE F

                   A           B          C        D         E   F

Model     Control outputs   No. of    Power    Terminal  Input  Options                                        Meaning
E5CC            1 and 2     auxiliary  supply     type    type
                            outputs    voltage

                                                                                                             48 48 mm

                                                                                    Control output 1                                       Control output 2

       RX                                                                               Relay output                                            None
       QX
*1 *3 CX                                                                             Voltage output                                             None
       QQ                                                                           (for driving SSR)

       CQ                                                                      Linear current output *2                                         None

                                                                                     Voltage output                                         Voltage output
                                                                                    (for driving SSR)                                      (for driving SSR)

                                                                               Linear current output *2                                     Voltage output
                                                                                                                                           (for driving SSR)

                            3                                                                           3 (one common)

                                       A                                                                100 to 240 VAC

                                       D                                                                     24 VAC/DC

                                                5                                       Screw terminals (with cover)

                                                          M                                             Universal input

                                                                          HB alarm and  Communications                             Event   Remote Transfer
                                                                          HS alarm                                                 inputs  SP Input output

                                                                 000      ---                           ---                        ---     ---        ---

                                                                *1 001    1                             ---                        2       ---        ---

                                                                          2

                                                                *1 003 (for 3-phase RS-485                                         ---     ---        ---

                                                                          heaters)

                                                                *3 004    ---                           RS-485                     2       ---        ---

                                                                 005      ---                           ---                        4       ---        ---

                                                                 006      ---                           ---                        2            Provided.

                                                                 007      ---                           ---                        2 Provided. ---

*1. Options with HB and HS alarms (001 and 003) cannot be selected if a linear current output is selected for the control output.

*2. The control output cannot be used as a transfer output.

*3. Option 004 can be selected only when "CX" is selected for the control outputs.

Heating and Cooling Control

Using Heating and Cooling Control

A Control Output Assignment
If there is no control output 2, an auxiliary output is used as the cooling control output.
If there is a control output 2, the two control outputs are used for heating and cooling.
(It does not matter which output is used for heating and which output is used for cooling.)
B Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.

                                                                                                                                                              3
   E5CC

   Optional Products (Order Separately)                                  Front Covers         Model
                                                                                            Y92A-48H
   USB-Serial Conversion Cable                                                       Type   Y92A-48D
                                                                          Hard Front Cover
                         Model                                            Soft Front Cover
                      E58-CIFQ2

   Terminal Covers                                                       CX-Thermo Support Software

                         Model                                                                 Model
                     E53-COV17                                                            EST2-2C-MV4
                     E53-COV23
   Note: The E53-COV10 cannot be used.                                   Note: CX-Thermo version 4.5 or higher is required for the E5CC.
           Refer to page 12 for the mounted dimensions.                          For the system requirements for the CX-Thermo, refer to
                                                                                 information on the EST2-2C-MV4 on the OMRON website
   Waterproof Packing                                                            (www.ia.omron.com).

                         Model
                        Y92S-P8
   Note: This Waterproof Packing is provided with the Digital
           Temperature Controller.

   Current Transformers (CTs)

   Hole diameter   Model
       5.8 mm     E54-CT1
       12.0 mm    E54-CT3

   Adapter

                         Model
                        Y92F-45
   Note: Use this Adapter when the panel has already been prepared for
           an E5B@ Controller.

   Waterproof Cover

                         Model
                       Y92A-48N

   Mounting Adapter

                         Model
                        Y92F-49
   Note: This Mounting Adapter is provided with the Digital Temperature
           Controller.

   DIN Track Mounting Adapter

                         Model
                        Y92F-52

4
                                                                                                                             E5CC

Specifications

Ratings

Power supply voltage                 A in model number: 100 to 240 VAC, 50/60 Hz
                                     D in model number: 24 VAC, 50/60 Hz; 24 VDC

Operating voltage range              85% to 110% of rated supply voltage

Power consumption                    Models with option selection of 000: 5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at 24 VAC or
                                                                                     1.6 W max. at 24 VDC

                                     All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC

Sensor input                         Temperature input
                                          Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Input impedance                           Platinum resistance thermometer: Pt100 or JPt100
Control method                            Infrared temperature sensor (ES1B): 10 to 70C, 60 to 120C, 115 to 165C, or 140 to 260C

                                     Analog input
                                           Current input: 4 to 20 mA or 0 to 20 mA
                                           Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

                                     Current input: 150  max., Voltage input: 1 M min.
                                     (Use a 1:1 connection when connecting the ES2-HB/THB.)

                                     ON/OFF control or 2-PID control (with auto-tuning)

Control    Relay output              SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations,
output                               minimum applicable load: 5 V, 10 mA *
           Voltage output
           (for driving SSR)         Output voltage: 12 VDC 20% (PNP), max. load current: 21 mA, with short-circuit protection circuit
           Linear current output
                                     4 to 20 mA DC/0 to 20 mA DC, load: 500  max., resolution: approx. 10,000*

Auxiliary  Number of outputs         3
output     Output specifications
                                     SPST-NO relay outputs, 250 VAC, Models with 3 outputs: 2 A (resistive load),
                                     Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V

                   Number of inputs  2 or 4 (depends on model)
                                     Contact input: ON: 1 k max., OFF: 100 k min.
Event input External contact input   Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
                   specifications    Current flow: Approx. 7 mA per contact

Transfer   Number of outputs         1 (only on models with a transfer output)
output     Output specifications
                                     Contact output: 4 to 20 mA DC, load: 500  max., resolution: approx. 10,000
Setting method                       Linear voltage output: 1 to 5 VDC, load: 1 k max, resolution: Approx. 10,000

                                     Digital setting using front panel keys

Remote SP input                      Current input: 4 to 20 mA DC or 0 to 20 mA DC (input impedance: 150  max.)
                                     Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V (input impedance: 1 M min.)

Indication method                    11-segment digital display and individual indicators
                                     Character height: PV: 15.2 mm, SV: 7.1 mm

Multi SP                             Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or
Bank switching                       serial communications.

                                     None

Other functions                      Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater
Ambient operating temperature        burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital
                                     filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root,
                                     MV change rate limit, simple calculations, temperature status display, simple programming, moving
                                     average of input value, and display brightness setting

                                     -10 to 55C (with no condensation or icing),
                                     for 3-year warranty: -10 to 50C (with no condensation or icing)

Ambient operating humidity           25% to 85%

Storage temperature                  -25 to 65C (with no condensation or icing)

* You cannot select a relay output or linear current output for control output 2.

                                                                                                                                                     5
   E5CC

   Input Ranges

   Thermocouple/Platinum Resistance Thermometer (Universal inputs)

   Input type                                 Platinum resistance                                                               Thermocouple                                                          Infrared temperature
                                                   thermometer
      Name                                                                                                                                                                                                   sensor

                2300                               Pt100          JPt100                 K              J               T       EL          U                  NR           S     B     W       PLII  10 to  60 to 115 to 140 to
                1800                                                                                                                                                                                  70C   120C 165C 260C
                1700                                                                               850             400 400.0                                               1700  1800  2300
                1600                                                                                        400.0  -200 -199.9
                1500                                                                                                                                                 1700    0
                1400                                                                               -100 -20.0       9 10
                1300                                                            1300                                                                           1300        17                   1300
                1200                                                                                78
                1100  Temperature range (C)  850                                                                                         850
                1000
                                                   500.0          500.0                     500.0                               600
                  900                                                                                                                               400 400.0
                  800
                  700                                      100.0         100.0                                                                                                                                                      260
                  600                                                                                                                                                                                          120 165
                  500                                                                                                                                                                                 90
                  400
                  300                                      0.0           0.0                                                                                         0           100            0     0      0  0    0
                  200                                                                                                                                                                        0
                  100                                                                       -20.0                                     -100
                                                                                                                                                                                 18 19
                     0                        -200 -199.9         199.9         -200                                            -200        -200 -199.9 -200
                 -100
                 -200                         0123456                                                                           11 12 13 14 15 16                                               20 21 22 23 24

     Setting
    number

                                              Shaded settings are the default settings.

   The applicable standards for the input types are as follows:                                    JPt100: JIS C 1604-1989, JIS C 1606-1989
   K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 60584-1                                            Pt100: JIS C 1604-1997, IEC 60751
   L: Fe-CuNi, DIN 43710-1985                                                                      PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)
   U: Cu-CuNi, DIN 43710-1985
   W: W5Re/W26Re, ASTM E988-1990

   Analog input

                      Input type                           Current                                 Voltage

   Input                                           4 to 20 mA 0 to 20 mA 1 to 5 V 0 to 5 V                         0 to 10 V
   specification                                                                                                       29

   Setting range                                   Usable in the following ranges by scaling:
                                                   -1999 to 9999, -199.9 to 999.9,
                                                   -19.99 to 99.99 or -1.999 to 9.999

   Setting number 25                                                     26                 27     28

6
                                                                                                                                                   E5CC

Alarm Outputs

Each alarm can be independently set to one of the following 19 alarm types. The default is 2: Upper limit. (see note.)
Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed.

        To use alarm 1, set the output assignment to alarm 1.

Set                                                     Alarm output operation
value
               Alarm type              When alarm value X When alarm value X                                      Description of function

                                            is positive                        is negative

0 Alarm function OFF                                              Output OFF                    No alarm

                                       ON                LH                                     Set the upward deviation in the set point for the alarm upper
                                       OFF                                                      limit (H) and the lower deviation in the set point for the alarm
1          Upper- and lower-limit *1                              PV *2                         lower limit (L). The alarm is ON when the PV is outside this
                                                                                                deviation range.
                                                         SP

    2                                  ON                      X          ON   X                  Set the upward deviation in the set point by setting the alarm
(default)                              OFF                                                  PV value (X). The alarm is ON when the PV is higher than the
           Upper-limit                                            PV      OFF

                                                         SP                    SP               SP by the deviation or more.

                                       ON                X                ON         X          Set the downward deviation in the set point by setting the

3 Lower-limit                          OFF                        PV      OFF               PV alarm value (X). The alarm is ON when the PV is lower than
                                                           SP
                                                                               SP               the SP by the deviation or more.

           Upper- and lower-limit      ON                LH                                     Set the upward deviation in the set point for the alarm upper
           range *1                    OFF                                                      limit (H) and the lower deviation in the set point for the alarm
4                                                                 PV *3                         lower limit (L). The alarm is ON when the PV is inside this de-
                                                                                                viation range.
                                                         SP

5          Upper- and lower-limit      ON                LH       PV *4                         A standby sequence is added to the upper- and lower-limit
                                                          SP                                    alarm (1). *6
           with standby sequence *1 *5 OFF

           Upper-limit with standby    ON                      X          ON   X
           sequence                    OFF
6                                                                 PV      OFF               PV A standby sequence is added to the upper-limit alarm (2). *6

                                                         SP                    SP

7          Lower-limit with standby    ON                X                ON       X
           sequence                    OFF                SP
                                                                  PV      OFF            PV A standby sequence is added to the lower-limit alarm (3). *6

                                                                               SP

           Absolute-value upper-lim- ON                     X             ON      X             The alarm will turn ON if the process value is larger than the

8          it                          OFF                        PV      OFF           0 PV alarm value (X) regardless of the set point.
                                                      0

                                       ON                   X             ON      X             The alarm will turn ON if the process value is smaller than the
                                       OFF
9          Absolute-value lower-limit                             PV      OFF           0 PV alarm value (X) regardless of the set point.

                                            0

           Absolute-value upper-lim- ON                     X             ON      X             A standby sequence is added to the absolute-value upper-

10         it with standby sequence OFF 0                         PV      OFF           0 PV limit alarm (8). *6

           Absolute-value lower-limit ON                    X             ON      X             A standby sequence is added to the absolute-value lower-

11         with standby sequence       OFF                        PV      OFF           0 PV limit alarm (9). *6
                                                      0

12 LBA (alarm 1 type only)                                             -                        *7

13 PV change rate alarm                                                -                        *8

           SP absolute-value           ON        X                        ON      X             This alarm type turns ON the alarm when the set point (SP)
           upper-limit alarm           OFF  0
14                                                                SP      OFF           0 SP is higher than the alarm value (X).

           SP absolute-value           ON        X                        ON      X             This alarm type turns ON the alarm when the set point (SP)
           lower-limit alarm           OFF  0
15                                                                SP      OFF           0 SP is lower than the alarm value (X).

                                       Standard Control Standard Control

                                       ON                   X             ON      X

                                       OFF                        MV      OFF               MV
                                                      0
           MV absolute-value                                                            0       This alarm type turns ON the alarm when the manipulated
           upper-limit alarm *9
16                                     Heating/Cooling                    Heating/Cooling       variable (MV) is higher than the alarm value (X).

                                       Control (Heating MV) Control (Heating MV)

                                       ON                   X

                                       OFF                        MV Always ON
                                                      0

                                       Standard Control Standard Control

                                       ON                   X             ON      X

                                       OFF  0                     MV      OFF           0   MV

17         MV absolute-value           Heating/Cooling                    Heating/Cooling       This alarm type turns ON the alarm when the manipulated
           lower-limit alarm *9        Control (Cooling MV)               Control (Cooling MV)  variable (MV) is lower than the alarm value (X).

                                       ON                   X

                                       OFF                        MV Always ON
                                                      0

           RSP absolute-value          ON        X                        ON      X             This alarm type turns ON the alarm when the remote SP
           upper-limit alarm *10       OFF  0                             OFF
18                                                                RSP                   0 RSP (RSP) is higher than the alarm value (X).

           RSP absolute-value          ON        X                        ON      X             This alarm type turns ON the alarm when the remote SP
           lower-limit alarm *10       OFF  0                             OFF
19                                                                RSP                   0 RSP (RSP) is lower than the alarm value (X).

                                                                                                                                                                  7
   E5CC

   *1 With set values 1, 4 and 5, the upper and lower limit values can be set  *4 Set value: 5, Upper- and lower-limit with standby sequence
         independently for each alarm type, and are expressed as "L" and "H."
                                                                                       For Upper- and Lower-Limit Alarm Described Above *2
   *2 Set value: 1, Upper- and lower-limit alarm
                                                                                     Case 1 and 2
   Case 1          Case 2          Case 3 (Always ON)     H<0, L<0                     Always OFF when the upper-limit and lower-limit hysteresis overlaps.
                                        H SP L
          L H SP     SP L H                               H<0, L>0                   Case 3: Always OFF
       H<0, L>0        H>0, L<0       H L SP               |H|  |L|
        |H| < |L|       |H| > |L|             SP H L      H>0, L<0             *5. Set value: 5, Upper- and lower-limit with standby sequence
                                                           |H|  |L|                    Always OFF when the upper-limit and lower-limit hysteresis overlaps.

   *3 Set value: 4, Upper- and lower-limit range                               *6 Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.
                                                                                     H174) for information on the operation of the standby sequence.
   Case 1          Case 2          Case 3 (Always OFF)    H<0, L<0
                                                                               *7 Refer to the E5@C Digital Temperature Controllers User's Manual (Cat.
          L H SP     SP L H               H SP L          H<0, L>0                   No.H174) for information on the loop burnout alarm (LBA).
       H<0, L>0        H>0, L<0        H L SP              |H|  |L|
        |H| < |L|       |H| > |L|                                              *8 Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.
                                                                                     H174) for information on the PV change rate alarm.
                                                  SP H L  H>0, L<0
                                                           |H|  |L|            *9 When heating/cooling control is performed, the MV absolute upper limit
                                                                                     alarm functions only for the heating operation and the MV absolute lower
                                                                                     limit alarm functions only for the cooling operation.

                                                                               *10 This value is displayed only when a remote SP input is used. It functions in
                                                                                     both Local SP Mode and Remote SP Mode.

8
                                                                                                                                E5CC

Characteristics

                                       Thermocouple: (0.3% of PV or 1C, whichever is greater) 1 digit max. *1

Indication accuracy                    Platinum resistance thermometer: (0.2% of PV or 0.8C, whichever is greater) 1 digit
(at the ambient temperature of 23C)
                                       Analog input:    0.2% FS 1 digit max.

                                       CT input:        5% FS 1 digit max.

Transfer output accuracy               0.3% FS max.

Remote SP Input Type                   0.2% FS 1 digit max.

Influence of temperature *2            Thermocouple input (R, S, B, W, PL II): (1% of PV or 10C, whichever is greater) 1 digit max.
Influence of voltage *2                Other thermocouple input: (1% of PV or 4C, whichever is greater) 1 digit max. *3
                                       Platinum resistance thermometer: (1% of PV or 2C, whichever is greater) 1 digit max.
                                       Analog input: 1%FS 1 digit max.
                                       CT input: 5% FS 1 digit max.
                                       Remote SP input: 1% FS 1 digit max.

Input sampling period                  50 ms

Hysteresis                             Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                       Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

Proportional band (P)                  Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                       Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I)                      0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D)                    0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Proportional band (P) for cooling      Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                       Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I) for cooling          0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D) for cooling        0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Control period                         0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)

Manual reset value                     0.0 to 100.0% (in units of 0.1%)

Alarm setting range                    -1999 to 9999 (decimal point position depends on input type)

Influence of signal source resistance  Thermocouple: 0.1C/ max. (100 max.)
                                       Platinum resistance thermometer: 0.1C/ max. (10  max.)

Insulation resistance                  20 M min. (at 500 VDC)

Dielectric strength                    2,300 VAC, 50/60 Hz for 1 min between terminals of different charge

Vibration   Malfunction                10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
            Resistance                 10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions

Shock       Malfunction                100 m/s2, 3 times each in X, Y, and Z directions
            Resistance                 300 m/s2, 3 times each in X, Y, and Z directions

Weight                                 Controller: Approx. 120 g, Mounting Bracket: Approx. 10 g

Degree of protection                   Front panel: IP66, Rear case: IP20, Terminals: IP00

Memory protection                      Non-volatile memory (number of writes: 1,000,000 times)

Setup Tool                             CX-Thermo version 4.5 or higher

Setup Tool port                        E5CC top panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect to a USB port on
                                                                the computer. *5

                   Approved standards  UL 61010-1, CSA C22.2 No. 611010-1 (evaluated by UL), KOSHA certified (some models) *6, Korean
Standards                              Radio Waves Act (Act 10564)

            Conformed standards EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II, Lloyd's standards *7

                                       EMI:                                                 EN61326

                                       Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A

                                       Noise Terminal Voltage:                              EN 55011 Group 1, class A

                                       EMS:                                                 EN 61326

EMC                                    ESD Immunity:                                        EN 61000-4-2
                                       Electromagnetic Field Immunity:                      EN 61000-4-3

                                       Burst Noise Immunity:                                EN 61000-4-4

                                       Conducted Disturbance Immunity:                      EN 61000-4-6

                                       Surge Immunity:                                      EN 61000-4-5

                                       Voltage Dip/Interrupting Immunity:                   EN 61000-4-11

*1 The indication accuracy of K thermocouples in the -200 to 1300C range, T and N thermocouples at a temperature of -100C max., and U and
     L thermocouples at any temperatures is 2C 1 digit max. The indication accuracy of the B thermocouple at a temperature of 400C max. is
     not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800C is 3C max. The indication accuracy of the R and
     S thermocouples at a temperature of 200C max. is 3C 1 digit max. The indication accuracy of W thermocouples is (0.3% of PV or 3C,
     whichever is greater) 1 digit max. The indication accuracy of PL II thermocouples is 0.3% of PV or 2C, whichever is greater, 1 digit max.

*2 Ambient temperature: -10C to 23C to 55C, Voltage range: -15% to 10% of rated voltage
*3 K thermocouple at -100C max.: 10C max.
*4 The unit is determined by the setting of the Integral/Derivative Time Unit parameter.
*5 External communications (RS-485) and USB-serial conversion cable communications can be used at the same time.
*6 Access the following website for information on certified models. http://www.ia.omron.com/support/models/index.html
*7 Refer to information on maritime standards in Shipping Standards on page 52 for compliance with Lloyd's Standards.

                                                                                                                                                     9
E5CC

USB-Serial Conversion Cable                                                                                                     When Digital Temperature Controllers are con-
                                                                                                                                nected, the parameters can be copied from the
    Applicable OS          Windows 2000, XP, Vista, or 7                                                                        Digital Temperature Controller that is set as the
                                                                                                                                master to the Digital Temperature Controllers that
    Applicable software    CX-Thermo version 4.5 or higher                                                                      are set as slaves.
                                                                                                                                Number of connected Digital Temperature Con-
    Applicable models      E5@C Series and E5CB Series                                                                          trollers: 32 max. (including master)

    USB interface standard Conforms to USB Specification 2.0.                Communications                                     When Digital Temperature Controllers are con-
                                                                             between components*                                nected, set points and RUN/STOP commands
    DTE speed              38400 bps                                                                                            can be sent from the Digital Temperature Control-
                                                                                                                                ler that is set as the master to the Digital Temper-
    Connector              Computer: USB (type A plug)                                                                          ature Controllers that are set as slaves.
    specifications         Digital Temperature Controller:                                                                      Slope and offsets can be set for the set point.
                           Special serial connector                                                                             Number of connected Digital Temperature Con-
                                                                                                                                trollers: 32 max. (including master)
    Power supply           Bus power (Supplied from USB host controller.)*

    Power supply voltage 5 VDC

    Current consumption    450 mA max.                                       MELSEC is a registered trademark of Mitsubishi Electric Corporation.
    Output voltage
                           4.70.2 VDC                                       * A Temperature Controller with version 1.1 or higher is required.
                           (Supplied from USB-Serial Conversion Cable to
                           the Digital Temperature Controller.)              Current Transformer (Order Separately)
                                                                             Ratings
    Output current         250 mA max.
                           (Supplied from USB-Serial Conversion Cable to
                           the Digital Temperature Controller.)

    Ambient operating      0 to 55C (with no condensation or icing)         Dielectric strength                                1,000 VAC for 1 min
    temperature                                                              Vibration resistance                               50 Hz, 98 m/s2

    Ambient operating      10% to 80%                                        Weight                                             E54-CT1: Approx. 11.5 g,
    humidity                                                                                                                    E54-CT3: Approx. 50 g
                                                                             Accessories
    Storage temperature -20 to 60C (with no condensation or icing)          (E54-CT3 only)                                     Armatures (2)
                                                                                                                                Plugs (2)
    Storage humidity       10% to 80%

    Altitude               2,000 m max.

    Weight                 Approx. 120 g                                     Heater Burnout Alarms and SSR Failure
                                                                             Alarms
Windows is a registered trademark of Microsoft Corporation in the
                                                                             CT input (for heater                               Models with detection for singlephase
United States and or other countries.                                        current detection)                                 heaters: One input
                                                                                                                                Models with detection for singlephase or
* Use a high-power port for the USB port.                                    Maximum heater                                     three-phase heaters: Two inputs
Note: A driver must be installed on the computer. Refer to the               current
                                                                             Input current                                      50 A AC
        Instruction Manual included with the Cable for the installation      indication accuracy
        procedure.                                                           Heater burnout                                     5% FS 1 digit max.
                                                                             alarm setting range
Communications Specifications                                                *1                                                 0.1 to 49.9 A (in units of 0.1 A)
                                                                             SSR failure alarm                                  Minimum detection ON time: 100 ms *3
    Transmission line      RS-485: Multidrop                                 setting range *2
    connection method      RS-485 (two-wire, half duplex)                                                                       0.1 to 49.9 A (in units of 0.1 A)
                           Start-stop synchronization                                                                           Minimum detection OFF time: 100 ms *4
    Communications         CompoWay/F, or Modbus
                           19200, 38400, or 57600 bps
    Synchronization
    method

    Protocol

    Baud rate

    Transmission code      ASCII                                             *1 For heater burnout alarms, the heater current will be measured
    Data bit length*
    Stop bit length*       7 or 8 bits                                            when the control output is ON, and the output will turn ON if the

    Error detection        1 or 2 bits                                            heater current is lower than the set value (i.e., heater burnout

    Flow control           Vertical parity (none, even, odd)                      detection current value).
                           Block check character (BCC) with
                           CompoWay/F or CRC-16 Modbus                       *2 For SSR failure alarms, the heater current will be measured when
                                                                                  the control output is OFF, and the output will turn ON if the heater
                           None                                                   current is higher than the set value (i.e., SSR failure detection
                                                                                  current value).
    Interface              RS-485
                                                                             *3 The value is 30 ms for a control period of 0.1 s or 0.2 s.
    Retry function         None                                              *4 The value is 35 ms for a control period of 0.1 s or 0.2 s.

    Communications buffer  217 bytes                                         Electrical Life Expectancy Curve for
                                                                             Relays (Reference Values)
    Communications         0 to 99 ms
    response wait time     Default: 20 ms

* The baud rate, data bit length, stop bit length, and vertical parity can   Life ( 104 operations)  500
  be individually set using the Communications Setting Level.                                         300

Communications Functions

                           You can use the memory in the PLC to read and                              100
                           write E5@C parameters, start and stop operation,
                           etc. The E5@C automatically performs communi-                               50
                           cations with PLCs. No communications program-                               30
                           ming is required.
    Programless            Number of connected Temperature Controllers:                               10
    communications*        32 max.
                           Applicable PLCs
                                                                                                      5       E5CC
                              OMRON PLCs
                                  SYSMAC CS Series, CJ Series, or                                     3       250 VAC, 30 VDC
                                  CP Series
                                                                                                              (resistive load)
                              Mitsubishi Electric PLCs
                                  MELSEC Q Series or L Series                                                 cos = 1

                                                                                                      1

                                                                                                           0  1        2        3  4  5  6

                                                                                                                                   Switching current (A)

10
                                                                                                                                                 E5CC

External Connections

E5CC                                                                                       E5CC-@@ 3 @ 5 M - @@@

        Control output 1                                                                       (1) (2) (3) (4) (5) (6)

      Relay output                     Control output 2          Auxiliary outputs 1 to 3                              
      250 VAC, 3A                                                                                              Terminal type
      (resistive load)                 Voltage output           Relay outputs
      Voltage output                   (for driving SSR)        Models with 3 auxiliary    The E5CC is set for a K-type thermocouple (input type = 5) by
      (for driving SSR)                12 VDC, 21 mA            outputs: 250 VAC, 2 A      default. An input error (s.err) will occur if the input type setting does
      12 VDC, 21 mA                                             (resistive load)           not agree with the temperature sensor. Check the input type.
      Linear current output
      0 to 20 mA DC
      4 to 20 mA DC
      Load: 500  max.

(1) Control outputs 1, 2                                           QQ

     RX              QX                          CX                                     CQ

Models with  Models with 1             Models with Models with 2                     Models with 2 Outputs: Linear Current  (2) Auxiliary Outputs
1 Relay      Voltage Output                                     Voltage Outputs      Output and Voltage (for Driving SSR)            Auxiliary outputs 1, 2, 3
Output       (for Driving SSR)         1 Linear
                                       Current Output (for Driving SSR)

1            OUT1 1          +  OUT1   1             +    OUT1  1             OUT1      1    OUT1                                 7   Auxiliary output 3
2            R2              -  Q      2             -    C     2           +Q             +C
                                       3                                                                                          8
                                                                            -  Q        2  -   Q                                         Auxiliary output 2
                                                                            +  OUT2     3  +   OUT2                               9
3            3                                                  3                                                                        Auxiliary output 1

                                                                                                                                  10  

                                                                                     1     13              7

                                                                                     2     14              8

(5) Sensor (Temperature/Analog) Input                                                3     15              9                (3) Input Power Supply
                                                                                                                             100 to 240 VAC 24 VAC/DC
   TC            Pt                 I        V                                       4     16        10
    4        A4
-5            B                +4             4                                      5     17        11
                             mA 5        -5
+6                5                    V6                                            6     18        12                     11               11
              B                 -        +
                                    6                                                                                       12               12
                  6

                                                                                                                                          (no polarity)

(6) Options                     003                       004                              005                006                         007
    001                         Communications            Communications                   Event Inputs       Event Inputs                Event Inputs
    Event Inputs 1              (RS-485), CT1,            (RS-485), and                    1 to 4             1 and 2, and                1 and 2, and
    and 2, and CT1              and CT2                   Event Inputs 3 and 4                                Transfer Output             Remote SP Input
                                                                                                       13
         13                            B(+)                         B(+)                                                      13                                      13
                                                                                                       14
EV1 14                                       13                           13                                           EV1 14                   EV1 14
                                                                                                 EV1               EV2 15
EV2 15                             RS-485                       RS-485                                                                 +  EV2 15
                                                                                            EV2 15                            16  +V
CT1      16                                  14                           14                           16                         I       +     +                     16
                                                                                                                              17                mA
         17                            A(-)                         A(-)                        EV3 17                                 -     V                        17
                                                                                            EV4 18                            18
         18                                  15                           15                                                              -                           18

                                             16                           16

                                  CT1                             EV3 17
                                                               EV4 18
                                       COM 17

                                  CT2

                                             18

Note: 1. The application of the terminals depends on the model.
        2. Do not wire the terminals that are shown with a gray background.
        3. When complying with EMC standards, the cable that connects the sensor must be 30 m or less.
            If the cable length exceeds 30 m, compliance with EMC standards will not be possible.
        4. Connect M3 crimped terminals.

Isolation/Insulation Block Diagrams

Models with 3 Auxiliary Outputs

     Power                   Sensor input, CT inputs, and remote SP input
     supply                         Communications and event inputs
                                     Voltage output (for driving SSR),

                                linear current output, and transfer output

                                                  Relay output
                                           Auxiliary outputs 1, 2, 3

                      : Reinforced insulation
                      : Functional isolation

Note: Auxiliary outputs 1 to 3 are not insulated.

                                                                                                                                                                          11
E5CC                                         Front panel

Nomenclature

E5CC

                       Temperature unit                                                                                     No. 1 display
                  Operation indicators                                                                                   PV or specified parameter

                                                                                                                             No. 2 display                                                  Top View of E5CC
                                                                                                                         SP or specified parameter value

                                                                                                                                                        Top-panel Setup Tool port

                                                                                                                    Use the U D Keys to set the
                                                                                                                    parameter.

                                Press O Key once to go to Adjustment Level.                                         Use S Key to change the digit (default setting).
                                Press O Key for at least 3 seconds to go to Initial Setting Level.                   Use the M Key to change to another parameter.

Dimensions                                                                                                                                                                                                    (Unit: mm)

Controllers

E5CC                                                                                                                                                                               Panel Cutout

                                                                   73.1                                                                               Mounted Separately                           Group Mounted
                                         4
                                                                                                                                                                                                   (48 number of units - 2.5)+10.0
                                                               60
                  48 48                         1

                                                                                                                                                                                                                             45+00.6

                                                                                                                    44.8 44.8 48.8 58               60 min.                                      Group mounting does
                                                                                                                                                                                                   not allow waterproofing.

                                                                                                                                                                                   45+00.6

                  Waterproof Packing         Mounting Adapter                                                       Terminal Cover                            45+00.6
                  (Accessory)                (Accessory)                                                            (E53-COV17)
                                                                                                                    (Sold separately)    Recommended panel thickness is 1 to 5 mm.
                                                                                                                                          Group mounting is not possible in the vertical direction. (Maintain
                  The Setup Tool port is on the top of the Temperature Controller.
                  It is used to connect the Temperature Controller to the computer                                                         the specified mounting space between Controllers.)
                  to use the Setup Tool.                                                                                                 To mount the Controller so that it is waterproof, insert the
                  The E58-CIFQ2 USB-Serial Conversion Cable is required to
                  make the connection.                                                                                                     waterproof packing onto the Controller.
                  Refer to the instructions that are provided with the USB-Serial                                                         When two or more Controllers are mounted, make sure that the
                  Conversion Cable for the connection procedure.
                                                                                                                                           surrounding temperature does not exceed the allowable operating
                  Note: Do not leave the USB-Serial Conversion Cable                                                                       temperature specified in the specifications.
                          connected when you use the Temperature Controller.                                                             To attach the USB-Serial Conversion Cable to the control panel,
                                                                                                                                           use a panel thickness of 1 to 2.5 mm.

Accessories (Order Separately)                                                                                                                        (2,110)                                                 (5) (15)
                                                                                                                                                                   (13)
USB-Serial Conversion Cable
E58-CIFQ2                                                                                                                                       (87)                                        1,740
                                                                                                                                       LED (RD)
                                                                                                               250

                                                                                                                                                                                   (250)

                                         USB connector (type A plug)

Terminal Covers                         48                                                                                                               LED (PWR)                                                 Serial connector
                                                                                                                                                          LED (SD)
E53-COV17                                                                                                                                                                                                     Terminal Cover
                                                                                                                     Terminal Covers                                                                          (E53-COV23)
                  48.8                                                                                              E53-COV23 (Three Covers provided.)

                  22                                                                                                                                                          2 3.8
                  9.1                                                                                                                                             10

                                                                                                                                                      44.8

12
                                                                                                                                                                                                            E5CC

Waterproof Packing                                                       The Waterproof Packing is provided with the Temperature Controller.
Y92S-P8 (for DIN 48 48)                                                 Order the Waterproof Packing separately if it becomes lost or damaged.
                                                                          The Waterproof Packing can be used to achieve an IP66 degree of protection.
                                                                          (Deterioration, shrinking, or hardening of the waterproof packing may occur depending on the
                                                                          operating environment. Therefore, periodic replacement is recommended to ensure the level of
                                                                          waterproofing specified in IP66. The time for periodic replacement depends on the operating
                                                                          environment. Be sure to confirm this point at your site.
                                                                          Consider three years a rough standard.)
                                                                          The Waterproof Packing does not need to be attached if a waterproof structure is not required.

Current Transformers                                                     21                                                        Thru-current (Io) vs. Output Voltage (Eo)
E54-CT1                                                                   15
                                                                                                           2.8                      (Reference Values)
                                                               25 3                      5.8 dia.                     7.5
                                                                                                                                    E54-CT1
                                                                      10
                                                                                                                                    Maximum continuous heater current: 50 A (50/60 Hz)
E54-CT3
                                                                                                                                    Number of windings:                                                4002
                                                               40 40
                                                                                                                                    Winding resistance:                                                182

                                                                                                   10.5                             Output voltage (Eo) V (r.m.s.)  100V Frequency: 50 Hz

                                                                          40                                                                                              10                                Distortion
                                                                                            Two, 3.5 dia.                                                                  1
                                                                                                                                                                                 1k                         factor
                                                                                                                                                                    100mV
                                                                                                                                                                                                            10%

                                                                                                                                                                                                             3%
                                                                                                                                                                                                         1%

                                                                           30                                                                                       10                          100

                                                                                                             2.36 dia.                                              1                           RL=10
                                                                          30

                                                                                           12 dia.
                                                                                                                                 9

                                                                                                                                                                    100V

                                                                                                                                                                    10

                                                                                                                                                                              1  10 100mA 1          10     100 1,000A

                                                                                                                                                                                                Thru-current (Io) A (r.m.s.)

                                                                                                                                    Thru-current (Io) vs. Output Voltage (Eo)

                                                                   Two, M3 (depth: 4)                                               (Reference Values)
                           15
                                                                                                                                    E54-CT3
                                                   30
                                                                                                                                    Maximum continuous heater current: 120 A (50/60 Hz)

                                                                                                                                    (Maximum continuous heater current for an OMRON
                                                                                                                                    Digital Temperature Controller is 50 A.)

E54-CT3 Accessories                                                                                                                 Number of windings:                                              4002
Armature
                                                                          Connection Example                                        Winding resistance:                                              80.8
  Approx. 3 dia.
                                                                                                   Armature                         Output voltage (Eo) V (r.m.s.)  100V Frequency: 50 Hz

                                                                          Plug                                                                                      10                                              Distortion
                                                                                                                                                                                                                    factor
                                                                                                                                                                                 1k                                 10%

                                                                                                           Lead                                                                  500                               3%
                                                                                                                                                                                                                 1%
                                                                                                                                                                    1

Plug               18                                                                                                                                             100mV                        100
                (22)                                                                                                                                                      10                    50
Approx. 6 dia.                                                                                                                                                             1
                                                                                                                                                                                                RL=10

                                                                                                                                                                    100V         10 100mA    1       10     100 1,000A
                                                                                                                                                                         10
                                                                                                                                                                            1

                                                                                                                                                                                                Thru-current (Io) A (r.m.s.)

                                                                                                                                                                                                                              13
E5CC

Adapter  Note: 1. Use this Adapter when the Front Panel has already been prepared for the E5B@.
                  2. Only black is available.
Y92F-45           3. You cannot use the E58-CIFQ2 USB-Serial Conversion Cable if you use the Y92F-45 Adapter. To use the USB-Serial
                      Conversion Cable to make the settings, do so before you mount the Temperature Controller in the panel.

                                                                                             Fixture (Accessory)

                                                   4.7                              76

                                                                               69.6 to 77.6

                             72 72

                                                                                             67 67 87

Mounted to E5CC                                    Panel (1 to 8 mm)                    Mounting Adapter
                                                                                        Y92F-30
                             72 72                                                    (Accessory)

                                          48 48

                                          2.2           4.7

                                                                  62.8
                                                        To back of the E5CC

DIN Track Mounting Adapter

Y92F-52   Note: This Adapter cannot be used together with the Terminal Cover.
                  Remove the Terminal Cover to use the Adapter.

                                                                                             This Adapter is used to mount the

                                                                                                 E5CC to a DIN Track.

                                                                               61

                                                                                                 If you use the Adapter, there is no

                                                                                             need for a plate to mount in the

                                                                                             panel or to drill mounting holes in

                                                                               3.5           the panel.

                             50                    38

    Mounted to E5CC

                                      48

                                                             80.5

14
                                                                                                     E5CC

Watertight Cover                                       21.9 14                    Mounting Adapter
                                                         (2)
Y92A-48N                                                                          Y92F-49
                                                                            69
                   87.7 79.2                                                                                           The Mounting Adapter is provided with the
                                                  67.6                        12                                       Temperature Controller.
                                                                                                                       Order this Adapter separately if it becomes
                                                                                                                       lost or damaged.

Protective Cover                                                                  Protective Cover

Y92A-48D  Note: This Protective Cover cannot be used Y92A-48H

                  if the Waterproof Packing is installed.                                            This Protective Cover is hard type.

                   This Protective Cover is soft type.                                               Please use it for the mis-operation
                   It is able to operate the controller with using                                   prevention etc.

                   this cover.

                                                                                                                                                                    15
    Digital Temperature Controller

    E5EC/E5AC (48 96 mm/96 96 mm)

Large White PV Display That's Easier to Read.
Easy to Use, from Model Selection to
Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.

    A white LCD PV display with a height of approx. 18 mm for the

    E5EC and 25 mm for the E5AC improves visibility.

    Tool ports are provided both on the top panel and the front panel.

    Set up the Controller without wiring the power supply by                  48 96 mm         96 96 mm
    connecting to the computer with a Communications Conversion                   E5EC               E5AC
    Cable (sold separately). Setup is easy with the CX-Thermo (sold

     separately).                                                             Refer to your OMRON website for the most recent
    High-speed sampling at 50 ms.                                           information on applicable safety standards.

    Models are available with up to 4 auxiliary outputs, up to 6 event

    inputs, a transfer output, and a remote SP input to cover a wide          Refer to Safety Precautions on page 50.

    range of applications.

    Short body with depth of only 60 mm.

    Easy connections to a PLC with programless communications.

    Use component communications to link Temperature Controllers to each other.

    The new position-proportional control models allow you to control valves as well.

Main I/O Functions

    Sensor Input                            E5EC      E5AC
      Universal input
                                                                              Three-level Display       4-digit
    Thermocouple                                                            PV, SV, and MV displayed  displays
    Pt                                                                      at the same time.
    Analog current/voltage
                                                                              Control Output 1
          Indication Accuracy
          Thermocouple input:                                                Relay output
          0.3% of PV                                                          Voltage output (for driving SSR)
          Pt input: 0.2% of PV                                              Linear current output
          Analog input: 0.2% of FS
                                                                              Control Output 2
          Sampling Period
          50 ms                                                             Voltage output (for driving SSR)
                                                                               Relay output
     Event Inputs                                                             Linear current output
    None
    2                                       PF (shift) Key                  Auxiliary Outputs
    4                                       Setup Tool port on front panel  4
    6                                       Temperature status display
                                             Simple programming              Transfer Output
    Remote SP Input                         Independent heating and          None
    None                                                                    1
    1                                       cooling PID control
                                             Changed parameter display
    Serial Communications                   Display brightness setting
    None
    RS-485

    This datasheet is provided as a guideline for selecting products.
    Be sure to refer to the following manuals for application precautions and other information required for operation before attempting
    to use the product.

       E5@C Digital Temperature Controllers User's Manual (Cat. No. H174)
       E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)

16
                                                                                                                                 E5EC/E5AC

Model Number Legend and Standard Models

Model Number Legend

E5EC-@@ @ @ @ @ -@@@ (Example: E5EC-RX4A5M-000)

           -- - - - - ---
             A BC DE F

E5AC-@@ @ @ @ @ -@@@ (Example: E5AC-RX4A5M-000)

           -A- - B - C -D - E -F--

                     A                 B          C         D                  E   F

Model           Control outputs     No. of auxil- Power  Terminal           Input  Options                   Meaning
                      1 and 2         iary out- supply     type             type
                                        puts voltage

E5EC                                                                                                         48 96 mm

E5AC                                                                                                         96 96 mm

                                                                                                      Control output 1           Control output 2

            RX                                                                                        Relay output                    None

            QX                                                                                         Voltage output                 None
                                                                                                      (for driving SSR)

        *2 CX                                                                                    Linear current output                None

            QQ                                                                                         Voltage output             Voltage output
                                                                                                      (for driving SSR)          (for driving SSR)

            QR                                                                                         Voltage output            Relay output
                                                                                                      (for driving SSR)

            RR                                                                                        Relay output               Relay output

        *2 CC                                                                                    Linear current output           Linear current out-
                                                                                                                                           put

        *2 CQ                                                                                    Linear current output            Voltage output
                                                                                                                                 (for driving SSR)

            PR                                                                              Position-proportional relay output   Position-proportion-
                                                                                                                                    al relay output

                                 *3 4                                                       4 (auxiliary outputs 1 and 2 with same common and auxilia-
                                                                                                         ry outputs 3 and 4 with same common)

                                               A                                                        100 to 240 VAC

                                               D                                                             24 VAC/DC

                Control outputs 1 and 2                  5                                            Screw terminals (with cover)

            For RX,                                                         M                           Universal input

            QX, QQ, For CX or       For PR                                                  HB alarm  Communications     Event   Remote Transfer
            QR, RR, or CC                                                                   and                          inputs  SP Input output
                                                                                            HS alarm
            CQ

            Selectable Selectable Selectable                                       000      ---         ---              ---     ---        ---

Option                  Selectable Selectable                                      004      ---         RS-485           2       ---        ---

selection               Selectable                                                 005      ---         ---              4       ---        ---

conditions                                                                                  2

*1          Selectable                                                             009 (for 3-phase RS-485               2       ---        ---

                                                                                            heaters)

            Selectable                                                             010      1           ---              4       ---        ---

            Selectable                                                             011      1           ---              6 Provided. Provided.

                        Selectable                                                 013      ---         ---              6 Provided. Provided.

                        Selectable Selectable                                      014      ---         RS-485           4 Provided. Provided.

*1. The options that can be selected depend on the type of control output.
*2. The control output cannot be used as a transfer output.
*3. A model with four auxiliary outputs must be selected.

Heating and Cooling Control

l Using Heating and Cooling Control

A Control Output Assignment
If there is no control output 2, an auxiliary output is used as the cooling control output.
If there is a control output 2, the two control outputs are used for heating and cooling.
(It does not matter which output is used for heating and which output is used for cooling.)
B Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.

                                                                                                                                                      17
E5EC/E5AC

Optional Products (Order Separately)                                  Current Transformers (CTs)

USB-Serial Conversion Cable                                           Hole diameter   Model
                                                                          5.8 mm     E54-CT1
                      Model                                               12.0 mm    E54-CT3
                   E58-CIFQ2

Communications Conversion Cable                                       CX-Thermo Support Software

                      Model                                                                 Model
                 E58-CIFQ2-E                                                           EST2-2C-MV4

Note: Always use this product together with the E58-CIFQ2.            Note: CX-Thermo version 4.5 or higher is required for the E5EC.
        This Cable is used to connect to the front-panel Setup Tool           For the system requirements for the CX-Thermo, refer to
        port.                                                                 information on the EST2-2C-MV4 on the OMRON website
                                                                              (www.ia.omron.com).
Terminal Covers

                      Model
                  E53-COV24

Waterproof Packing

    Applicable Controller     Model
               E5EC          Y92S-P9

    E5AC                     Y92S-P10

Note: This Waterproof Packing is provided with the Digital
        Temperature Controller.

Waterproof Cover               Model
                             Y92A-49N
Applicable Controller       Y92A-96N
             E5EC
             E5AC

Front Port Cover

                      Model
                     Y92S-P7
Note: This Front Port Cover is provided with the Digital Temperature
        Controller.

Mounting Adapter

                      Model
                     Y92F-51
Note: This Mounting Adapter is provided with the Digital Temperature
        Controller.

18
Specifications            E5EC                                                                   E5EC/E5AC
Ratings                   E5AC
                                     A in model number: 100 to 240 VAC, 50/60 Hz
Power supply voltage                D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range             85% to 110% of rated supply voltage
                                     Models with option selection of 000:6.6 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or
Power consumption
                                                                                     2.3 W max. at 24 VDC
Sensor input                         All other models: 8.3 VA max. at 100 to 240 VAC, and 5.5 VA max. at 24 VAC or 3.2 W max. at 24 VDC
                                     Models with option selection of 000:7.0 VA max. at 100 to 240 VAC, and 4.2 VA max. at 24 VAC or
Input impedance
                                                                                     2.4 W max. at 24 VDC
Control method                       All other models: 9.0 VA max. at 100 to 240 VAC, and 5.6 VA max. at 24 VAC or 3.4 W max. at 24 VDC
                                     Temperature input
Control       Relay output           Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
output                               Platinum resistance thermometer: Pt100 or JPt100
              Voltage output         Infrared temperature sensor (ES1B): 10 to 70C, 60 to 120C, 115 to 165C, or 140 to 260C
Auxiliary     (for driving SSR)      Analog input
output        Linear current output  Current input: 4 to 20 mA or 0 to 20 mA
              Number of outputs      Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
                                     Current input: 150  max., Voltage input: 1 M min.
              Output specifications  (Use a 1:1 connection when connecting the ES2-HB/THB.)
                                     ON/OFF or 2-PID control (with autotuning)
              Number of inputs       SPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations,
                                     minimum applicable load: 5 V, 10 mA
Event input External contact input   Output voltage: 12 VDC 20% (PNP), max. load current: 40 mA, with short-circuit protection circuit
                   specifications    (The maximum load current is 21 mA for models with two control outputs.)
                                     4 to 20 mA DC/0 to 20 mA DC, load: 500  max., resolution: approx. 10,000
Transfer      Number of outputs      4
output        Output specifications  SPST-NO. relay outputs, 250 VAC, Models with 4 outputs: 2 A (resistive load),
                                     Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V
Remote SP input                      2, 4 or 6 (depends on model)
                                     Contact input: ON: 1 k max., OFF: 100 k min.
Potentiometer input                  Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Setting method                       Current flow: Approx. 7 mA per contact
                                     1 (only on models with a transfer output)
Indication method                    Current output: 4 to 20 mA DC, Load: 500  max., Resolution: Approx. 10,000
                                     Linear voltage output: 1 to 5 VDC, load: 1 k max, Resolution: Approx. 10,000
Multi SP                             Current input: 4 to 20 mA DC or 0 to 20 mA DC (input impedance: 150  max.)
Bank switching                       Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V (input impedance: 1 M min.)
                                     100  to 10 k
Other functions                      Digital setting using front panel keys
                                     11-segment digital display and individual indicators
Ambient operating temperature        Character height: E5EC: PV: 18.0 mm, SV: 11.0 mm, MV: 7.8 mm

Ambient operating humidity                                     E5AC: PV: 25.0 mm, SV: 15.0 mm, MV: 9.5 mm
Storage temperature                  Three displays Contents: PV/SV/MV, PV/SV/Multi-SP, or PV/SV/Remaining soak time
                                     Numbers of digits: 4 digits each for PM, SV, and MV displays
                                     Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or
                                     serial communications.
                                     None
                                     Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater
                                     burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital
                                     filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root,
                                     MV change rate limit, simple calculations, temperature status display, simple programming, moving
                                     average of input value, and display brightness setting
                                     -10 to 55C (with no condensation or icing),
                                     for 3-year warranty: -10 to 50C (with no condensation or icing)
                                     25% to 85%
                                     -25 to 65C (with no condensation or icing)

                                     19
E5EC/E5AC

Input Ranges

Thermocouple/Platinum Resistance Thermometer (Universal inputs)

    Input type                              Platinum resistance                                              Thermocouple                                                                   Infrared temperature
                                                 thermometer                                                                                                                                         sensor

    Name                                    Pt100         JPt100               K              J           T  EL                             U          N      R     S     B     W     PLII  10 to  60 to 115 to 140 to
                                                                                                                                                                                            70C   120C 165C 260C

                            2300                                                                                                                                                2300
                            1800
                            1700                                                                                                                                          1800

                                                                                                                                                              1700  1700

                            1600

                            1500

                            1400                                         1300                                                                          1300                           1300
                            1300
    Temperature range (C)
                            1200

                            1100

                            1000                                                         850                                          850
                                       850

                             900

                            800

                            700                                                                                                  600
                                                                                                 400.0 400 400.0
                            600             500.0         500.0                   500.0

                            500                                                                                                             400 400.0

                            400                                                                                                                                                                                                         260
                                                                                                                                                                                                                   120 165
                            300                                                                                                                                                                          90
                                                                                                                                                                          100
                            200                    100.0          100.0

                            100

                            -100                   0.0            0.0                                                                                         0     0           0     0     0      0  0  0

                            -200                                                  -20.0 -100 -20.0                                    -100

                                  -200 -199.9             -199.9         -200                        -200 -199.9 -200                       -200 -199.9 -200

    Setting                       0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
     range

                            Shaded settings are the default settings.

The applicable standards for the input types are as follows:                                     JPt100: JIS C 1604-1989, JIS C 1606-1989
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 60584-1                                             Pt100: JIS C 1604-1997, IEC 60751
L: Fe-CuNi, DIN 43710-1985                                                                       PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)
U: Cu-CuNi, DIN 43710-1985
W: W5Re/W26Re, ASTM E988-1990

Analog input

    Input type                                         Current                                   Voltage

    Input                                   4 to 20 mA 0 to 20 mA 1 to 5 V 0 to 5 V                          0 to 10 V
    specification                                                                                                29

    Setting range                           Usable in the following ranges by scaling:
                                            -1999 to 9999, -199.9 to 999.9,
                                            -19.99 to 99.99 or -1.999 to 9.999

    Setting number                                 25             26              27             28

20
                                                                                                                                  E5EC/E5AC

Alarm type

Each alarm can be independently set to one of the following 19 alarm types. The default is 2: Upper limit. (see note.)
Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed.

        To use alarm 1, set the output assignment to alarm 1.

Set                                                     Alarm output operation
value
               Alarm type              When alarm value X When alarm value X                                      Description of function

                                            is positive                        is negative

0 Alarm function OFF                                              Output OFF                    No alarm

                                       ON                LH                                     Set the upward deviation in the set point for the alarm upper
                                       OFF                                                      limit (H) and the lower deviation in the set point for the alarm
1          Upper- and lower-limit *1                              PV *2                         lower limit (L). The alarm is ON when the PV is outside this
                                                                                                deviation range.
                                                         SP

    2                                  ON                      X          ON   X                  Set the upward deviation in the set point by setting the alarm
(default)                              OFF                                                  PV value (X). The alarm is ON when the PV is higher than the
           Upper-limit                                            PV      OFF

                                                         SP                    SP               SP by the deviation or more.

                                       ON                X                ON         X          Set the downward deviation in the set point by setting the

3 Lower-limit                          OFF                        PV      OFF               PV alarm value (X). The alarm is ON when the PV is lower than
                                                           SP
                                                                               SP               the SP by the deviation or more.

           Upper- and lower-limit      ON                LH                                     Set the upward deviation in the set point for the alarm upper
           range *1                    OFF                                                      limit (H) and the lower deviation in the set point for the alarm
4                                                                 PV *3                         lower limit (L). The alarm is ON when the PV is inside this de-
                                                                                                viation range.
                                                         SP

5          Upper- and lower-limit      ON                LH       PV *4                         A standby sequence is added to the upper- and lower-limit
                                                          SP                                    alarm (1). *6
           with standby sequence *1 *5 OFF

           Upper-limit with standby    ON                      X          ON   X
           sequence                    OFF
6                                                                 PV      OFF               PV A standby sequence is added to the upper-limit alarm (2). *6

                                                         SP                    SP

7          Lower-limit with standby    ON                X                ON       X
           sequence                    OFF                SP
                                                                  PV      OFF            PV A standby sequence is added to the lower-limit alarm (3). *6

                                                                               SP

           Absolute-value upper-lim- ON                     X             ON      X             The alarm will turn ON if the process value is larger than the

8          it                          OFF                        PV      OFF           0 PV alarm value (X) regardless of the set point.
                                                      0

                                       ON                   X             ON      X             The alarm will turn ON if the process value is smaller than the
                                       OFF
9          Absolute-value lower-limit                             PV      OFF           0 PV alarm value (X) regardless of the set point.

                                            0

           Absolute-value upper-lim- ON                     X             ON      X             A standby sequence is added to the absolute-value upper-

10         it with standby sequence OFF 0                         PV      OFF           0 PV limit alarm (8). *6

           Absolute-value lower-limit ON                    X             ON      X             A standby sequence is added to the absolute-value lower-

11         with standby sequence       OFF                        PV      OFF           0 PV limit alarm (9). *6
                                                      0

12 LBA (alarm 1 type only)                                             -                        *7

13 PV change rate alarm                                                -                        *8

           SP absolute-value           ON        X                        ON      X             This alarm type turns ON the alarm when the set point (SP)
           upper-limit alarm           OFF  0
14                                                                SP      OFF           0 SP is higher than the alarm value (X).

           SP absolute-value           ON        X                        ON      X             This alarm type turns ON the alarm when the set point (SP)
           lower-limit alarm           OFF  0
15                                                                SP      OFF           0 SP is lower than the alarm value (X).

                                       Standard Control Standard Control

                                       ON                   X             ON      X

                                       OFF                        MV      OFF               MV
                                                      0
           MV absolute-value                                                            0       This alarm type turns ON the alarm when the manipulated
           upper-limit alarm *9
16                                     Heating/Cooling                    Heating/Cooling       variable (MV) is higher than the alarm value (X).

                                       Control (Heating MV) Control (Heating MV)

                                       ON                   X

                                       OFF                        MV Always ON
                                                      0

                                       Standard Control Standard Control

                                       ON                   X             ON      X

                                       OFF  0                     MV      OFF           0   MV

17         MV absolute-value           Heating/Cooling                    Heating/Cooling       This alarm type turns ON the alarm when the manipulated
           lower-limit alarm *9        Control (Cooling MV)               Control (Cooling MV)  variable (MV) is lower than the alarm value (X).

                                       ON                   X

                                       OFF                        MV Always ON
                                                      0

           RSP absolute-value          ON        X                        ON      X             This alarm type turns ON the alarm when the remote SP
           upper-limit alarm *10       OFF  0                             OFF
18                                                                RSP                   0 RSP (RSP) is higher than the alarm value (X).

           RSP absolute-value          ON        X                        ON      X             This alarm type turns ON the alarm when the remote SP
           lower-limit alarm *10       OFF  0                             OFF
19                                                                RSP                   0 RSP (RSP) is lower than the alarm value (X).

                                                                                                                                                                  21
E5EC/E5AC

*1 With set values 1, 4 and 5, the upper and lower limit values can be set  *4. Set value: 5, Upper- and lower-limit with standby sequence
     independently for each alarm type, and are expressed as "L" and "H."
                                                                                    For Upper- and Lower-Limit Alarm Described Above *2
*2. Set value: 1, Upper- and lower-limit alarm
                                                                                  Case 1 and 2
    Case 1          Case 2          Case 3 (Always ON)                              Always OFF when the upper-limit and lower-limit hysteresis overlaps.

      L H SP        SP L H                        H SP L  H<0, L<0                Case 3: Always OFF
                                                H L SP
    H<0, L>0         H>0, L<0                             H<0, L>0          *5. Set value: 5, Upper- and lower-limit with standby sequence
    |H| < |L|         |H| > |L|                            |H|  |L|               Always OFF when the upper-limit and lower-limit hysteresis overlaps.
                                                          H>0, L<0
                                                SP H L     |H|  |L|         *6. Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.
                                                                                  H174) for information on the operation of the standby sequence.
*3. Set value: 4, Upper- and lower-limit range
                                                                            *7. Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.
    Case 1          Case 2          Case 3 (Always OFF)   H<0, L<0                H174) for information on the PV change rate alarm. This setting cannot be
                                                                                  used with a position-proportional model.
           L H SP     SP L H               H SP L         H<0, L>0
        H<0, L>0        H>0, L<0        H L SP             |H|  |L|         *8. Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.
         |H| < |L|       |H| > |L|                                                H174) for information on the PV change rate alarm.

                                                SP H L    H>0, L<0          *9. When heating/cooling control is performed, the MV absolute upper limit
                                                           |H|  |L|               alarm functions only for the heating operation and the MV absolute lower
                                                                                  limit alarm functions only for the cooling operation.

                                                                            *10. This value is displayed only when a remote SP input is used. It functions in
                                                                                  both Local SP Mode and Remote SP Mode.

22
                                                                                                                    E5EC/E5AC

Characteristics

Indication accuracy                Thermocouple: (0.3% of PV or 1C, whichever is greater) 1 digit max. *1
(at the ambient temperature of     Platinum resistance thermometer: (0.2% of PV or 0.8C, whichever is greater) 1 digit
23C)                              Analog input: 0.2% FS 1 digit max.
                                   CT input: 5% FS 1 digit max.
                                   Potentiometer input: 5% FS 1 digit max.

Transfer output accuracy           0.3% FS max.

Remote SP Input Type               0.2% FS 1 digit max.

Influence of temperature *2        Thermocouple input (R, S, B, W, PL II): (1% of PV or 10C, whichever is greater) 1 digit max.
Influence of voltage *2            Other thermocouple input: (1% of PV or 4C, whichever is greater) 1 digit max. *3
                                   Platinum resistance thermometer: (1% of PV or 2C, whichever is greater) 1 digit max.
                                   Analog input: 1%FS 1 digit max.
                                   CT input: 5% FS 1 digit max.
                                   Remote SP input: 1% FS 1 digit max.

Input sampling period              50ms

Hysteresis                         Temperature input: 0.1 to 999.9C or F (in units of 0.1C orF)
                                   Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

Proportional band (P)              Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                   Analog input: 0.1 to 999.9% FS (in units of 0.1% FS)

Integral time (I)                  Standard, heating/cooling, or Position-proportional (Close): 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in
                                   units of 0.1 s)
                                   Position-proportional (Floating): 1 to 9999 s (in units of 1 s), 0.1 to 999.9 s (in units of 0.1 s)*4

Derivative time (D)                0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Proportional band (P) for cooling  Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                   Analog input: 0.1 to 999.9% FS (in units of 0.1% FS)

Integral time (I) for cooling      0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D) for cooling    0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Control period                     0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)

Manual reset value                 0.0 to 100.0% (in units of 0.1%)

Alarm setting range                -1999 to 9999 (decimal point position depends on input type)

Influence of signal source resis-  Thermocouple: 0.1C/ max. (100  max.)
tance                              Platinum resistance thermometer: 0.1C/ max. (10  max.)

Insulation resistance              20 M min. (at 500 VDC)

Dielectric strength                2,300 VAC, 50/60 Hz for 1 min between terminals of different charge

Vibration   Malfunction            10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
            Resistance             10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions

Shock       Malfunction            100 m/s2, 3 times each in X, Y, and Z directions
            Resistance             300 m/s2, 3 times each in X, Y, and Z directions

Weight                 E5EC        Controller: Approx. 210 g, Mounting Brackets: Approx. 4 g 2
                       E5AC        Controller: Approx. 250 g, Mounting Brackets: Approx. 4 g 2

Degree of protection               Front panel: IP66, Rear case: IP20, Terminals: IP00

Memory protection                  Non-volatile memory (number of writes: 1,000,000 times)

Setup Tool                         CX-Thermo version 4.5 or higher

Setup Tool port                    E5EC/E5AC top panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect to a USB port
                                                                     on the computer.*5

                                   E5EC/E5AC front panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion
                                                                     Cable are used together to connect to a USB port on the computer.*5

                  Approved standards UL 61010-1, CSA C22.2 No. 611010-1 (evaluated by UL), Korean Radio Waves Act (Act 10564)
Standards

                  Conformed standards EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II, Lloyd's standards *6

                                   EMI                                                  EN61326

                                   Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A

                                   Noise Terminal Voltage:                              EN 55011 Group 1, class A

                                   EMS:                                                 EN 61326

EMC                                ESD Immunity:                                        EN 61000-4-2

                                   Electromagnetic Field Immunity:                      EN 61000-4-3

                                   Burst Noise Immunity:                                EN 61000-4-4

                                   Conducted Disturbance Immunity:                      EN 61000-4-6

                                   Surge Immunity:                                      EN 61000-4-5

                                   Voltage Dip/Interrupting Immunity:                   EN 61000-4-11

*1 The indication accuracy of K thermocouples in the -200 to 1300C range, T and N thermocouples at a temperature of -100C max., and U and L thermocouples at
     any temperatures is 2C 1 digit max. The indication accuracy of the B thermocouple at a temperature of 400C max.
     is not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800C is 3C max. The indication accuracy of the R and S thermocouples
     at a temperature of 200C max. is 3C 1 digit max. The indication accuracy of W thermocouples is (0.3% of PV or 3C, whichever is greater) 1 digit max. The
     indication accuracy of PL II thermocouples is (0.3% of PV or 2C, whichever is greater) 1 digit max.

*2 Ambient temperature: -10C to 23C to 55C, Voltage range: -15% to 10% of rated voltage
*3 K thermocouple at -100C max.: 10C max.
*4 The unit is determined by the setting of the Integral/Derivative Time Unit parameter.

*5 External communications (RS-485) and USB-serial conversion cable communications can be used at the same time.

*6 Refer to information on maritime standards in Shipping Standards on page 52 for compliance with Lloyd's Standards.

                                                                                                                                                   23
E5EC/E5AC

USB-Serial Conversion Cable                                                                                               When Digital Temperature Controllers are con-
                                                                                                                          nected, the parameters can be copied from the
    Applicable OS        Windows 2000, XP, Vista, or 7                                                                    Digital Temperature Controller that is set as the
                                                                                                                          master to the Digital Temperature Controllers that
    Applicable software  CX-Thermo version 4.5 or higher                                                                  are set as slaves.
                                                                                                                          Number of connected Digital Temperature Con-
    Applicable models    E5@C Series and E5CB Series                                                                      trollers: 32 max. (including master)

    USB interface standard Conforms to USB Specification 2.0.                      Communications                         When Digital Temperature Controllers are con-
                                                                                   between components*                    nected, set points and RUN/STOP commands
    DTE speed            38,400 bps                                                                                       can be sent from the Digital Temperature Control-
                                                                                                                          ler that is set as the master to the Digital Temper-
    Connector            Computer: USB (type A plug)                                                                      ature Controllers that are set as slaves.
    specifications       Digital Temperature Controller:                                                                  Slope and offsets can be set for the set point.
                         Special serial connector                                                                         Number of connected Digital Temperature Con-
                                                                                                                          trollers: 32 max. (including master)
    Power supply         Bus power (Supplied from USB host controller.)*

    Power supply voltage 5 VDC

    Current consumption  450 mA max.                                               MELSEC is a registered trademark of Mitsubishi Electric Corporation.
    Output voltage
                         4.70.2 VDC                                               * A Temperature Controller with version 1.1 or higher is required.
                         (Supplied from USB-Serial Conversion Cable to
                         the Digital Temperature Controller.)                      Current Transformer (Order Separately)
                                                                                   Ratings
    Output current       250 mA max.
                         (Supplied from USB-Serial Conversion Cable to
                         the Digital Temperature Controller.)

    Ambient operating    0 to 55C (with no condensation or icing)                 Dielectric strength                    1,000 VAC for 1 min
    temperature                                                                    Vibration resistance                   50 Hz, 98 m/s2

    Ambient operating    10% to 80%                                                Weight                                 E54-CT1: Approx. 11.5 g,
    humidity                                                                                                              E54-CT3: Approx. 50 g
                                                                                   Accessories
    Storage temperature -20 to 60C (with no condensation or icing)                (E54-CT3 only)                         Armatures (2)
                                                                                                                          Plugs (2)
    Storage humidity     10% to 80%

    Altitude             2,000 m max.

    Weight               Approx. 120 g                                             Heater Burnout Alarms and SSR Failure
                                                                                   Alarms
Windows is a registered trademark of Microsoft Corporation in the
                                                                                   CT input (for heater                   Models with detection for singlephase
United States and or other countries.                                              current detection)                     heaters: One input
                                                                                                                          Models with detection for singlephase or
* Use a high-power port for the USB port.                                                                                 three-phase heaters: Two inputs

Note: A driver must be installed on the computer. Refer to the
        Instruction Manual included with the Cable for the installation
        procedure.

Communications Specifications                                                      Maximum heater                         50 A AC
                                                                                   current

    Transmission line    RS-485: Multidrop                                         Input current indica-                  5% FS 1 digit max.
    connection method                                                              tion accuracy

    Communications       RS-485 (two-wire, half duplex)                            Heater burnout
                                                                                   alarm setting range
    Synchronization      Start-stop synchronization                                *1                                     0.1 to 49.9 A (in units of 0.1 A)
    method                                                                                                                Minimum detection ON time: 100 ms *3

    Protocol             CompoWay/F, or Modbus                                     SSR failure alarm                      0.1 to 49.9 A (in units of 0.1 A)
                                                                                   setting range *2                       Minimum detection OFF time: 100 ms *4
    Baud rate            19200, 38400, or 57600 bps

    Transmission         ASCII                                                     *1. For heater burnout alarms, the heater current will be measured when the
    code                                                                                 control output is ON, and the output will turn ON if the heater current is
                                                                                         lower than the set value (i.e., heater burnout detection current value).
    Data bit length*     7 or 8 bits
                                                                                   *2. For SSR failure alarms, the heater current will be measured when the
    Stop bit length*     1 or 2 bits                                                     control output is OFF, and the output will turn ON if the heater current is
                                                                                         higher than the set value (i.e., SSR failure detection current value).
    Error detection      Vertical parity (none, even, odd)
                         Block check character (BCC) with                          *3. The value is 30 ms for a control period of 0.1 s or 0.2 s.
                         CompoWay/F or CRC-16 Modbus                               *4. The value is 35 ms for a control period of 0.1 s or 0.2 s.

    Flow control         None

    Interface            RS-485

    Retry function       None                                                      Electrical Life Expectancy Curve for
                                                                                   Relays (Reference Values)
    Communications buffer 217 bytes
                                                                                        500
    Communications       0 to 99 ms                                                     300Life ( 104 operations)
    response wait time   Default: 20 ms

* The baud rate, data bit length, stop bit length, and vertical parity can be in-
    dividually set using the Communications Setting Level.

Communications Functions                                                                                    100           E5EC/E5AC

                                                                                                                          250 VAC, 30 VDC

                                                                                                                          (resistive load)

                         You can use the memory in the PLC to read and                                      50            cos = 1
                         write E5@C parameters, start and stop operation,
                         etc. The E5@C automatically performs communi-                                      30
                         cations with PLCs. No communications program-
    Programless          ming is required.                                                                  10
    communications*      Number of connected Temperature Controllers:                                        5
                         32 max.                                                                             3
                         Applicable PLCs
                                                                                                            1
                            OMRON PLCs
                                SYSMAC CS Series, CJ Series, or CP Se-                                           0  1  2  3  4              5  6
                                ries
                                                                                                                             Switching current (A)
                            Mitsubishi Electric PLCs
                                MELSEC Q Series or L Series

24
                                                                                                                                                                              E5EC/E5AC

External Connections

E5EC/E5AC

                      E5EC-@@ 4 @ 5 M - @@@ E5AC-@@ 4 @ 5 M - @@@

                                    (1) (2) (3) (4) (5) (6)                                  (1) (2) (3) (4) (5) (6)                                 The E5EC is set for a K-type thermocouple (input
                                                                                                                                                     type = 5) by default. An input error (s.err) will occur
                                                                                                                                                     if the input type setting does not agree with the
                                              Terminal type                                            Terminal type
                                                                                                                                                     temperature sensor. Check the input type.

   Control output 1                Control output 2                Auxiliary outputs 1 to 4          (6) Options

  Relay output                  Relay output                       Relay output                             004                      005                  009                         010
  250 VAC, 5 A                  250 VAC, 5 A                       Models with 4 auxiliary                  Communications           4 event inputs       Communications, 2 event     4 event inputs
  (resistive load)              (resistive load)                   outputs: 250 VAC, 2 A                    and 2 event inputs                            inputs, and 2 CT inputs     and 1 CT input
  Voltage output                Voltage output                     (resistive load)
  (for driving SSR)             (for driving SSR)                                                               B(+)                             13           B(+)                              13
  12 VDC, 40 mA                 12 VDC, 21 mA                                                                            13                                            13
  When There Is a               Linear current output                                                                                      EV3 14                                     EV3 14
  Control Output 2:             0 to 20 mA DC                                                               RS-485                               15       RS-485                                15
  21 mA                         4 to 20 mA DC                                                                            14          EV4                               14             EV4
  Linear current output         Load: 500  max.
  0 to 20 mA DC                                                                                                 A(-)                                          A(-)
  4 to 20 mA DC                                                                                                          15                                            15
  Load: 500  max.
                                                                                                                  16                             16                16                           16
(1) Control output
                                                                                                            EV1   17                       EV1   17                    17             EV1       17
                                                                                                                                                               EV1
                                                                                                                  18                             18                18                           18
                                                                                                            EV2                      EV2                  EV2                         EV2
                                                                                                                  19                             19                19                           19
                                                                                                                                                                                      CT1
                                                                                                                  20                             20       CT1                                   20

                                                                                                                                                               COM 20

                                                                                                                  21                             21       CT2      21                           21

   RX                      QX                    CX                                                                          011
                                                                                                                             6 event Inputs, 1 CT input,
Models with           Models with 1          Models with 1                                                                   transfer output, and remote SP input
1 Relay Output        Voltage Output         Linear Current Output
                      (for Driving SSR)

    3          OUT1 3           +   OUT1     3           +  OUT1    (3) Input Power Supply                                                                     13
    4                           -            4           -  C
               R      4             Q                                                                                                                     EV3 14

    5                 5                      5                      100 to 240 VAC           24 VAC/DC                                               EV4       15
                                                                                    1                    1
                                                                                                                                                 28            16
    6                 6                      6
                                                                                         2           2                                  EV5 29            EV1 17

QQ                                  QR                                                       (no polarity)                           EV6         30  EV2       18

Models with 2 Voltage Models with Voltage Output (for                                                                                +           31            19
Outputs (for Driving SSR) Driving SSR) and Relay Output                                                                      Transfer V +            CT1
                                                                                                                                                 32            20
                                                                                                                             output        I
               OUT1                       OUT1
    3  +                     3         +                            1 25 13                                                          -           33            21
    4  -       Q             4         -  Q                         2 26 14
                                                                    3 27 15                                                          +           34
                                                                    4 28 16                                                                +
                                                                                                                             Remote     V  mA    35
                                                                                                                             SP
    5  +       Q             5            R                                                                                          -           36
    6  -                     6            OUT2
               OUT2

RR                PR                CC                              5 29 17                                                  013                                   014
                                                                    6 30 18                                                  6 event Inputs, transfer              Communications, 4 event Inputs,
Models with 2 Models with 2         Models with 2                   7 31 19                                                  output, and remote SP input           transfer output, and remote SP input
                                                                    8 32 20
Relay Outputs Position-proportional Linear Current                  9 33 21                                                                                                                          B(+)
                                                                    10 34 22                                                                                                                                  13
       OUT1       Relay Output Open Outputs     OUT1                11 35 23                                                                              13
                                                                                                                                                                                                 RS-485
3      R          3          R3              +  C                                                                                                    EV3 14                                                   14
4                                    4       -
                  4                                                                                                                                                                                   A(-)
                                                                                                                                                          15                                                  15
                                                                                                                                                     EV4
5             5                        5     +                                                                                             28                                     28                16
6      R                                     -  C                                                                                                         16
       OUT2 6                R
                                       6        OUT2                12 36 24                                                                 29      EV1 17                   EV5 29       EV1      17
                             Close                                           Potentiometer Input                                     EV5

CQ                                                                                                                           EV6           30        EV2  18           EV6        30       EV2      18

Models with 2 Outputs: Linear Current Output                                                                                 +             31             19              +       31                19
and Voltage (for Driving SSR)                                                                                     Transfer V +                            20   Transfer V +       32
                                                                                                                                           32                                                       20
                                                                                                                  output             I                         output         I
               OUT1
    3  +                 (2) Auxiliary Outputs                                                                               -             33             21               -      33                21
    4  -       C                  Auxiliary outputs 1, 2, 3, 4
                                                                                                                             +             34                              +      34
                                                                                            O 19                                     +                                        +
    5  +                                  7                                                 W 20                  Remote V           mA    35                  Remote V       mA  35
    6  -                                      Auxiliary output 4                            C 21                  SP -                     36                  SP -               36
               Q
                                          8
               OUT2                           Auxiliary output 3

                                          9                                                                                          Note: 1. The application of the terminals depends on
                                                                                                                                                   the model.
                                          10                        (5) Sensor (Temperature/Analog) Input
                                               Auxiliary output 2                                                                             2. Do not wire the terminals that are shown with
                                                                       TC                        Pt          I         V                           a gray background.
                                          11                                                 A
                                               Auxiliary output 1      22                              + 22            22                     3. When complying with EMC standards, the
                                                                    - 23                         22  mA 23         - 23                            cable that connects the sensor must be 30 m
                                          12                        + 24                     B                   V 24                              or less. If the cable length exceeds 30 m,
                                                                                                       -           +                               compliance with EMC standards will not be
                                                                                                 23        24                                      possible.
                                                                                             B 24

                                                                                                                                              4. Connect M3 crimped terminals.

Isolation/Insulation Block Diagrams

Models with 4 Auxiliary Outputs

       Power          Sensor input, CT inputs, potentiometer input, and remote SP input
       Supply                          Communications and event inputs
                                       Voltage output (for driving SSR),

                                  linear current output, and transfer output

                                                     Relay output
                                               Auxiliary outputs 1, 2
                                               Auxiliary outputs 3, 4

                             : Reinforced insulation
                             : Functional isolation

Note: Auxiliary outputs 1 to 2 and 3 to 4 are not insulated.

                                                                                                                                                                                                                  25
E5EC/E5AC

Nomenclature

E5EC

                                 Front panel

             Temperature unit                                              No. 1 display                                       Top View of E5EC
     Operation indicators                                               PV or specified parameter
                                                                                                                                                                 Top-panel
    Front-panel Setup Tool port                                           No. 2 display                                                                          Setup
                                                                        SP or specified parameter value                                                          Tool port

                                                                           No. 3 display
                                                                        Manipulated value or other value
                                                                         MUansieputhlaeteUd vaDlueKoeryosthtoersveatlue

                                                                          the parameter.

                                                                          Use S Key to change the digit (default setting).

                                                                                Use the M Key to change to another parameter.

    Press O Key once to go to Adjustment Level.

    Press O Key for at least 3 seconds to go to Initial Setting Level.

E5AC

                                 Front Panel

         Temperature unit                                                                                                               Top View of E5AC
     Operation indicators
                                                                                     No. 1 display
    Front-panel Setup Tool port                                                  PV or specified parameter

                                                                                     No. 2 display
                                                                                SP or specified parameter value

                                                                                     No. 3 display
                                                                                Manipulated value or other value

                                                                                Press the U or D Key to set the parameter.                                Top-panel
                                                                                Press the S Key to change the digit (default setting).                    Setup
                                                                                                                                                          Tool port

    Press the O Key once to go to the Adjustment Level.                         Press the M Key to change to another parameter.
    Press the O Key for at least 3 seconds to go to the Initial Setting Level.

26
Dimensions                                                                                                        E5EC/E5AC

Controllers                                                                                                                     (Unit: mm)

E5EC

                            48  4                              (64)                                  44
                                1                               60               110

                96                                                                                            The Setup Tool port is on the top of the Tem-
                                                                                                              perature Controller.
                                                                                                              It is used to connect the Temperature Con-
                                                                                                              troller to the computer to use the Setup Tool.
                                                                                                              The E58-CIFQ2 USB-Serial Conversion
                                                                                                              Cable is required to make the connection.
                                                                                                         91 Refer to the instructions that are provided
                                                                                                              with the USB-Serial Conversion Cable for the
                                                                                                              connection procedure.

                                                                                                             Note: Do not leave the USB-Serial
                                                                                                                      Conversion Cable connected when
                                                                                                                      you use the Temperature Controller.

                            Waterproof
                            Packing (Accessory) Mounting Adapter

                                                           (Accessory)

      Mounted Separately     Group Mounted *                                     * Selections for Control Outputs 1 and 2: QQ, QR, RR, CC, PR, or CQ
                                                                                     If you also specify 011, 013, or 014 for the option selection and use
                   45+0.06  (48 number of units - 2.5)+10.0                        group mounting, the ambient temperature must be 45C or less.
                                                                                     If the ambient temperature is 55C, maintain the following mounting
                                92+00.8                                              spaces between Controllers.

                                                                                                                        60 min.
                                                                                                             45-00.6

      120 min.              Group mounting does not
                            allow waterproofing.

                                                                                                         92+00.8

                92-00.8

                                                                                 120 min.

       Recommended panel thickness is 1 to 8 mm.

       Group mounting is not possible in the vertical direction. (Maintain the
        specified mounting space between Controllers.)

       To mount the Controller so that it is waterproof, insert the waterproof
        packing onto the Controller.

       When two or more Controllers are mounted, make sure that the
        surrounding temperature does not exceed the allowable operating
        temperature specified in the specifications.

       To attach the USB-Serial Conversion Cable to the control panel, use a
        panel thickness of 1 to 2.5 mm.

                                                                                                                                                            27
E5EC/E5AC                                                                                          (64)

E5AC

                                                                                             4     60

                                                                          96 x 96               1             91 x 91

                                                                                                         110  91

                                                                               Waterproof
                                                                               Packing (Accessory) Mounting Adapter

                                                                                                               (Accessory)

                                                 The Setup Tool port is on the top of the Temperature Controller.
                                                 It is used to connect the Temperature Controller to the computer to use the Setup Tool.
                                                 The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection.
                                                 Refer to the instructions that are provided with the USB-Serial Conversion Cable for the connection procedure.

                                                 Note: Do not leave the USB-Serial Conversion Cable connected when you use the Temperature Controller.

               Mounted Separately                    Group Mounted *                            Recommended panel thickness is 1 to 8 mm.

                               92+00.8           (96 number of units - 3.5)+10.0               Group mounting is not possible in the vertical direction. (Maintain the
                                                                                                  specified mounting space between Controllers.)
    120 min.                                                                        92+00.8
                                                                                                 To mount the Controller so that it is waterproof, insert the waterproof
                                                 Group mounting does not                          packing onto the Controller.
                                                 allow waterproofing.
                                                                                                 When two or more Controllers are mounted, make sure that the
                                                                                                  surrounding temperature does not exceed the allowable operating
                                                                                                  temperature specified in the specifications.

                                                                                                 To attach the USB-Serial Conversion Cable to the control panel, use a
                                                                                                  panel thickness of 1 to 2.5 mm.

                                        92+00.8

28
                                                                                                                                        E5EC/E5AC

Accessories (Order Separately)

USB-Serial Conversion Cable                                                                           (2,110)
                                                                                                                    (13)
E58-CIFQ2                                                                                                                                      (5) (15)
                                                                    250                          (87)                            1,740     Serial connector
                                                                                        LED(RD)                                         1510
                                                                                                                          (250)

                                                       USB connector (type A plug)

                                                                                                       LED(PWR)
                                                                                                       LED(SD)

Conversion Cable                                                   Connecting to the E58-CIFQ2 USB-Serial Conversion Cable
E58-CIFQ2-E
                                                                                                       (2110)
              Conversion Cable
                                                                    250                                                   263
                                               (1510)

                                                                                        E58-CIFQ2 (Order Separately)                    Conversion Cable

Note: Always use this product together with the E58-CIFQ2.

Terminal Covers                                                     Waterproof Packing
E53-COV24 (Three Covers provided.)                                  Y92S-P9 (for DIN 48 96)

                                                             2 3.8                              The Waterproof Packing is provided with the Temperature
                                                  10                                            Controller.
                                                                                                The degree of protection when the Waterproof Packing is used
                                       91                                                       is IP66.
                                                                                                Also, keep the Port Cover on the front-panel Setup Tool port
                                                                    Y92S-P10 (for DIN 96 96)  of the E5EC/E5AC securely closed.
                                                                                                To maintain an IP66 degree of protection, the Waterproof
                                                                                                Packing and the Port Cover for the front-panel Setup Tool port
                                                                                                must be periodically replaced because they may deteriorate,
                                                                                                shrink, or harden depending on the operating environment.
                                                                                                The replacement period will vary with the operating
                                                                                                environment.
                                                                                                Check the required period in the actual application.
                                                                                                Use 3 years or sooner as a guideline.
                                                                                                If a waterproof structure is not required, then the Waterproof
                                                                                                Packing does not need to be installed.

Setup Tool Port Cover for top panel                                                     Mounting Adapter
Y92S-P7                                                                                 Y92F-51 (for DIN 48 96)

                                                       Order this Port Cover                                                     One pair is provided with the
                                                       separately if the Port Cover on                                           Controller.
                                                       the front-panel Setup Tool port                                           Order this Adapter
                                                       is lost or damaged. The                                                   separately if it becomes lost
                                                       Waterproof Packing must be                                                or damaged.
                                                       periodically replaced because
                                                       it may deteriorate, shrink, or
                                                       harden depending on the
                                                       operating environment.

                                                                                                                                                                29
E5EC/E5AC                                                                                                                            Watertight Cover
                                                                                                                                    Y92A-96N (96 96)
Watertight Cover
Y92A-49N (48 96)

                                                                          21.9  (2)                                                                                                                                                    21.9 (2)

                131.7                                                                                                               131.7

                                             67.6                                29.4                                                                                      115.6                                                       29.4

Current Transformers                                                      21                                                              Thru-current (Io) vs. Output Voltage (Eo)
E54-CT1                                                                                                         2.8                        (Reference Values)
                                                                                                                                           E54-CT1
                                                               25 3        15
                                                                                            5.8 dia.                                       Maximum continuous heater current: 50 A (50/60 Hz)
                                                                      10                                                    7.5
                                                                                                                                           Number of windings:                                                                         4002
E54-CT3                                                                                             10.5
                                                                           40                                                              Winding resistance:                                                                         182
                                                               40 40
                                                                                              Two, 3.5 dia.                                                                Output voltage (Eo) V (r.m.s.)  100V Frequency: 50 Hz

                                                                          30                                                                                                                                     10                                  Distortion
                                                                                                                                                                                                                  1
                                                                                                             2.36 dia.                                                                                                         1k                    factor
                                                                          30                                                                                                                               100mV
                                                                                                                                                                                                                                                     10%
                                                                                            12 dia.
                                                                                                                                 9                                                                                                                       3%
                                                                                                                                                                                                                                                     1%

                                                                                                                                                                                                               10                      100

                                                                                                                                                                                                               1                       RL=10

                                                                                                                                                                                                           100V

                                                                                                                                                                                                               10

                                                                                                                                                                                                               1     10 100mA 1                  10  100 1,000A

                                                                           Two, M3 (depth: 4)                                                                                                                 Thru-current (Io) A (r.m.s.)
                                  15
                                                                                                                                           Thru-current (Io) vs. Output Voltage (Eo)
                                                          30                                                                               (Reference Values)
                                                                                                                                           E54-CT3

                                                                                                                                           Maximum continuous heater current: 120 A (50/60 Hz)

                                                                                                                                           (Maximum continuous heater current for an OMRON Digital
                                                                                                                                           Temperature Controller is 50 A.)

                                                                                                                                           Number of windings:                                                                         4002

E54-CT3 Accessories                                                                                                                        Winding resistance:                                                                         80.8
Armature
                                                                          Connection Example                                               Output voltage (Eo) V (r.m.s.)  100V Frequency: 50 Hz
  Approx. 3 dia.
                                                                                                                                                                                                           10                                           Distortion
                                                                                                                                                                                                                                                        factor
                                                                                     Armature                                                                                                                        1k                                 10%

                                                                          Plug                                                                                                                                       500                               3%
                                                                                                                                                                                                                                                     1%
                                                                                                                                                                                                           1

                                                                                               Lead

Plug                        18                                                                                                                                           100mV                                                        100
                       (22)                                                                                                                                                      10                                                    50
Approx. 6 dia.                                                                                                                                                                    1
                                                                                                                                                                                                                                       RL=10

                                                                                                                                                                           100V                                      10 100mA       1        10      100 1,000A
                                                                                                                                                                                10
                                                                                                                                                                                   1

                                                                                                                                                                                                                                       Thru-current (Io) A (r.m.s.)

30
MEMO

                                            31
    Digital Temperature Controller

    E5DC (22.5 mm Wide, and DIN Track-mounting Type)

The E5DC Mounts to DIN Track and Is Ideal
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and
Advanced Performance as the Rest of the
E5@C Series.

    A slim body at 85 22.5 mm (D W) that fits into narrow control

    panels and mounts to DIN Track.

    Removable terminal block for easy replacement to simplify maintenance.

    High-speed sampling at 50 ms for applications with high-speed

    temperature increases.

    Easy connections to a PLC with programless communications.

    Set up the Controller without wiring the power supply by connecting

     to the computer with a Communications Conversion Cable (sold separately).       22.5 mm Wide, and
     Setup is easy with the CX-Thermo (sold separately).                         DIN Track-mounting Type
    Models are available with up to 2 auxiliary outputs and 1 event input to
                                                                                               E5DC

     complete basic functions.                                                   Refer to your OMRON website for the most recent
    A white PV display (height: 8.5 mm) is easy to read when setting up,       information on applicable safety standards.

    checking alarms, and making settings in a control panel.                     Refer to Safety Precautions on page 50.

Main I/O Functions                                              E5DC             Dual displays: PV/SV 4-digit displays

                    Sensor Input                   PF (shift) Key              Control Output 1
                      Universal input               Temperature status display   Relay output
                                                    Simple programming          Voltage output (for driving SSR)
                     Thermocouple                  Independent heating and      Linear current output
                     Pt
                     Analog current/voltage        cooling PID control           Auxiliary Outputs
                                                    Changed parameter display    None
                          Indication Accuracy       Display brightness setting  2
                           Thermocouple input:
                           0.3% of PV
                           Pt input: 0.2% of PV
                           Analog input:
                          0.2% of FS

                           Sampling Period
                           50 ms

                     Event Inputs
                     None
                    1

                     Serial Communications
                     None
                     RS-485

    This datasheet is provided as a guideline for selecting products.
    Be sure to refer to the following manuals for application precautions and other information required for operation before attempting
    to use the product.
    E5@C Digital Temperature Controllers User's Manual (Cat. No. H174)
    E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)

32
                                                                                                                                          E5DC

Model Number Legend and Standard Models

Model Number Legend

E5DC-@@ @ @ @ @ -@@@ (Example: E5DC-RX0ASM-015)

           -- - - - - ---
             A BC DE F

Model      A          B                C         D                      E             F                 Meaning
E5DC                                                                               Options
        Control     No. of           Power    Terminal                 Input
        output 1   auxiliary         supply      type                  type
                   outputs           voltage

                                                                                                    22.5 mm wide and mounts to DIN Track

                                                                                                         Control output 1

        RX                                                                                               Relay output

        QX                                                                                                Voltage output
                                                                                                         (for driving SSR)
        CX
                       0                                                                                 Linear current output *5
                       2
                                      A                                                                  None
                                      D
                                                     S                                                   2 (one common)
                                                                    M
                                                                                                         100 to 240 VAC

                                                                                                         24 VAC/DC

                                                                                                         Screw terminals

                                                                                                         Universal input

                                                                                            HB alarm and HS alarm Communications Event input

                                                                              *1 000                ---                        ---        ---
                                                                              *2 002
                                                                              *3 015                1          RS-485                     ---
                                                                              *4 016
                                                                              *2 017                ---        RS-485                     ---

                                                                                                    ---                        ---        1

                                                                                                    1                          ---        1

*1 Option 000 can be selected only if two auxiliary outputs are selected.
*2 Options 002 and 017 can be selected only if the control output is a relay output or voltage output and two auxiliary outputs are selected.
*3 Option 015 cannot be selected if the control output is a relay output or voltage output and two auxiliary outputs are selected.
*4 Options 016 can be selected only if the control output is a linear current output and two auxiliary outputs are selected.
*5 The control output cannot be used as a transfer output.

List of Models

                                                                       Options                                      Model                      Model

Control output     No. of auxiliary  HB alarm and HS        No. of event inputs Communications           Power supply voltage       Power supply voltage
                        outputs              alarm
                                                                                                             100 to 240 VAC                24 VAC/DC
                   ---                                                                      RS-485
                                                ---                                                       E5DC-RX0ASM-015            E5DC-RX0DSM-015
                                                                              ---           ---           E5DC-RX2ASM-000            E5DC-RX2DSM-000
Relay output                                                                                              E5DC-RX2ASM-002            E5DC-RX2DSM-002
                   2                                                                        RS-485        E5DC-RX2ASM-017            E5DC-RX2DSM-017
                                     Detection for single-                                                E5DC-QX0ASM-015            E5DC-QX0DSM-015
                                                                                                          E5DC-QX2ASM-000            E5DC-QX2DSM-000
                                     phase heater                             1             ---           E5DC-QX2ASM-002            E5DC-QX2DSM-002
                                                                                                          E5DC-QX2ASM-017            E5DC-QX2DSM-017
                   ---                                                                      RS-485        E5DC-CX0ASM-015            E5DC-CX0DSM-015
                                                ---                                                       E5DC-CX2ASM-000            E5DC-CX2DSM-000
                                                                              ---           ---           E5DC-CX2ASM-015            E5DC-CX2DSM-015
Voltage output                                                                                            E5DC-CX2ASM-016            E5DC-CX2DSM-016

(for driving SSR)  2                 Detection for single-                                  RS-485

                                     phase heater                             1             ---

                   ---                                                                      RS-485

Linear current                                ---                             ---           ---

output             2                                                                        RS-485

                                                                              1             ---

Note: These products are sold as a set with a terminal block (i.e., Terminal Unit).

Heating and Cooling Control

Using Heating and Cooling Control

A Control Output Assignment
An auxiliary output is used as the cooling control output.
B Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.

                                                                                                                                                          33
E5DC

Optional Products (Order Separately)                                 End Plate  Model
                                                                     Spacer     PFP-M
USB-Serial Conversion Cable
                                                                                Model
                      Model                                                     PFP-S
                   E58-CIFQ2

Conversion Cable

                      Model                                          DIN Tracks

                 E58-CIFQ2-E                                                               Model
                                                                                         PFP-100N
Note: Always use this product together with the E58-CIFQ2.                               PFP-50N
        This Cable is used to connect to the front-panel Setup Tool
        port.

Current Transformers (CTs)

    Hole diameter              Model                                 Unit Labels
        5.8 mm                E54-CT1
        12.0 mm               E54-CT3                                                      Model
                                                                                          Y92S-L2
Mounting Adapters

                      Model
                     Y92F-53

Short Bars

                      Model
                    Y92S-P11

CX-Thermo Support Software

                      Model
                 EST2-2C-MV4

Note: CX-Thermo version 4.6 or higher is required for the E5DC.
        For the system requirements for the CX-Thermo, refer to
        information on the EST2-2C-MV4 on the OMRON website
        (www.ia.omron.com).

34
                                                                                                                        E5DC

Specifications

Ratings

Power supply voltage               A in model number: 100 to 240 VAC, 50/60 Hz
                                   D in model number: 24 VAC, 50/60 Hz; 24 VDC

Operating voltage range            85% to 110% of rated supply voltage

Power consumption                  4.9 VA max. at 100 to 240 VAC, and 2.8 VA max. at 24 VDC or 1.5 W max. at 24 VDC

Sensor input                       Temperature input
Input impedance                         Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
                                        Platinum resistance thermometer: Pt100 or JPt100
                                        Infrared temperature sensor (ES1B): 10 to 70C, 60 to 120C, 115 to 165C, or 140 to 260C

                                   Analog input
                                        Current input: 4 to 20 mA or 0 to 20 mA
                                        Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

                                   Current input: 150  max., Voltage input: 1 M min. (Use a 1:1 connection when connecting the ES2-HB/
                                   THB.)

Control method                     ON/OFF control or 2-PID control (with auto-tuning)

Control    Relay output            SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5
output                             V, 10 mA
           Voltage output
           (for driving SSR)       Output voltage 12 VDC 20% (PNP), max. Load current: 21 mA, with short-circuit protection circuit
           Linear current output
                                   4 to 20 mA DC/0 to 20 mA DC, load: 500  max., resolution: Approx. 10,000

Auxiliary  Number of outputs       2 (depends on model)

outputs    Output specifications   SPST-NO relay outputs: 250 VAC, 2 A (resistive load),
                                   Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V

Event      Number of inputs        1 (depends on model)
inputs                             Contact input ON: 1 k max., OFF: 100 k min.
           External contact input  Non-contact input ON: Residual voltage 1.5 V max.; OFF: Leakage current 0.1 mA max.
           specifications          Current flow: approx. 7 mA per contact

Setting method                     Digital setting using front panel keys

Indication method                  11-segment digital displays and individual indicators
                                   Character height: PV: 8.5 mm, SV: 8.0 mm

Multi SP                           Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or
                                   serial communications.*

Bank switching                     None
Other functions
Ambient operating temperature      Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burn-
                                   out (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self
                                   tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change
                                   rate limit, simple calculations, temperature status display, simple programming, moving average of input
                                   value, and display brightness setting

                                   -10 to 55C (with no condensation or icing), for 3-year warranty: -10 to 50C (with no condensation or
                                   icing)

Ambient operating humidity         25% to 85%
Storage temperature                -25 to 65C (with no condensation or icing)

* Only two set points are selectable for event inputs.

                                                                                                                                                35
E5DC

Input Ranges

Thermocouple/Platinum Resistance Thermometer (Universal inputs)

    Input type                                Platinum resistance                                                         Thermocouple                                                          Infrared temperature
                                                   thermometer                                                                                                                                           sensor
       Name
                                                   Pt100            JPt100               K            J          T        EL                    U          N       R     S     B     W    PLII  10 to 60 to 115 to 140 to
                 2300                                                                                                                                                                           70C 120C 165C 260C
                 1800                                                                            850                                                              1700  1700  1800  2300  1300
                 1700                                                            1300                     400.0                                            1300
                 1600                                                                                                                                               0     0   100     0     0
                 1500 Temperature range (C)  850                                                -100 -20.0                               850
                 1400                                                                                                                                             16    17    18    19    20
                 1300                              500.0          500.0                  500.0    78                                 600
                 1200                                                                                            400 400.0
                 1100                                                                                                                           400 400.0
                 1000
                                                           100.0          100.0                                                                                                                                               260
                   900                                                                                                                                                                                   120 165
                   800                                                                                                                                                                          90
                   700
                   600                                     0.0            0.0                                                                                                                   0  0  0  0
                   500
                   400                                                                    -20.0                                           -100
                   300                                                           -200
                   200                        -200 -199.9         -199.9                                         -200 -199.9 -200               -200 -199.9 -200
                   100                                                            56
                                              01234                                                              9 10 11 12 13 14 15                                                            21 22 23 24
                  -100
                  -200

      Setting
       range

                                              Shaded settings are the default settings.

The applicable standards for the input types are as follows:                                         JPt100: JIS C 1604-1989, JIS C 1606-1989
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 60584-1                                                 Pt100: JIS C 1604-1997, IEC 60751
L: Fe-CuNi, DIN 43710-1985                                                                           PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)
U: Cu-CuNi, DIN 43710-1985
W: W5Re/W26Re, ASTM E988-1990

Analog input

          Input type                                                Current                                      Voltage
    Input specification
                                                           4 to 20 mA 0 to 20 mA 1 to 5 V 0 to 5 V                        0 to 10 V
    Setting range                                                                                                             29
                                                           Usable in the following ranges by scaling:
    Setting number                                         -1999 to 9999, -199.9 to 999.9,
                                                           -19.99 to 99.99 or -1.999 to 9.999

                                                                25               26              27              28

36
                                                                                                                                                  E5DC

Alarm Types

Each alarm can be independently set to one of the following 17 alarm types. The default is 2: Upper limit. (See note.)
Auxiliary outputs are allocated to alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not

        displayed.
        To use alarm 1, set the output assignment to alarm 1.

Set                                                     Alarm output operation
value
               Alarm type              When alarm value X When alarm value X                                     Description of function

                                            is positive                       is negative

0 Alarm function OFF                                              Output OFF                   No alarm

                                       ON                LH                                    Set the upward deviation in the set point for the alarm upper
                                       OFF                                                     limit (H) and the lower deviation in the set point for the alarm
1          Upper- and lower-limit *1                              PV *2                        lower limit (L). The alarm is ON when the PV is outside this
                                                                                               deviation range.
                                                         SP

    2                                  ON                      X         ON   X                  Set the upward deviation in the set point by setting the alarm
(default)                              OFF                                                 PV value (X). The alarm is ON when the PV is higher than the
           Upper-limit                                            PV     OFF

                                                         SP                   SP               SP by the deviation or more.

                                       ON                X               ON         X          Set the downward deviation in the set point by setting the

3 Lower-limit                          OFF                        PV     OFF               PV alarm value (X). The alarm is ON when the PV is lower than
                                                           SP
                                                                              SP               the SP by the deviation or more.

           Upper- and lower-limit      ON                LH                                    Set the upward deviation in the set point for the alarm upper
           range *1                    OFF                                                     limit (H) and the lower deviation in the set point for the alarm
4                                                                 PV *3                        lower limit (L). The alarm is ON when the PV is inside this de-
                                                                                               viation range.
                                                         SP

5          Upper- and lower-limit      ON                LH       PV *4                        A standby sequence is added to the upper- and lower-limit
                                                          SP                                   alarm (1). *6
           with standby sequence *1 *5 OFF

           Upper-limit with standby    ON                      X         ON   X
           sequence                    OFF
6                                                                 PV     OFF               PV A standby sequence is added to the upper-limit alarm (2). *6

                                                         SP                   SP

7          Lower-limit with standby    ON                X               ON       X
           sequence                    OFF                SP
                                                                  PV     OFF            PV A standby sequence is added to the lower-limit alarm (3). *6

                                                                              SP

           Absolute-value upper-lim- ON                     X            ON      X             The alarm will turn ON if the process value is larger than the

8          it                          OFF                        PV     OFF           0 PV alarm value (X) regardless of the set point.
                                                      0

                                       ON                   X            ON      X             The alarm will turn ON if the process value is smaller than the
                                       OFF
9          Absolute-value lower-limit                             PV     OFF           0 PV alarm value (X) regardless of the set point.

                                            0

           Absolute-value upper-lim- ON                     X            ON      X             A standby sequence is added to the absolute-value upper-

10         it with standby sequence OFF 0                         PV     OFF           0 PV limit alarm (8). *6

           Absolute-value lower-limit ON                    X            ON      X             A standby sequence is added to the absolute-value lower-

11         with standby sequence       OFF                        PV     OFF           0 PV limit alarm (9). *6
                                                      0

12 LBA (alarm 1 type only)                                            -                        *7

13 PV change rate alarm                                               -                        *8

           SP absolute-value           ON        X                       ON      X             This alarm type turns ON the alarm when the set point (SP)
           upper-limit alarm           OFF  0
14                                                                SP     OFF           0 SP is higher than the alarm value (X).

           SP absolute-value           ON        X                       ON      X             This alarm type turns ON the alarm when the set point (SP)
           lower-limit alarm           OFF  0
15                                                                SP     OFF           0 SP is lower than the alarm value (X).

                                       Standard Control Standard Control

                                       ON                   X            ON      X

                                       OFF                        MV     OFF               MV
                                                      0
           MV absolute-value                                                           0       This alarm type turns ON the alarm when the manipulated
           upper-limit alarm *9
16                                     Heating/Cooling                   Heating/Cooling       variable (MV) is higher than the alarm value (X).

                                       Control (Heating MV) Control (Heating MV)

                                       ON                   X

                                       OFF                        MV Always ON
                                                      0

                                       Standard Control Standard Control

                                       ON                   X            ON      X

                                       OFF  0                     MV     OFF           0   MV

17         MV absolute-value           Heating/Cooling                   Heating/Cooling       This alarm type turns ON the alarm when the manipulated
           lower-limit alarm *9        Control (Cooling MV)              Control (Cooling MV)  variable (MV) is lower than the alarm value (X).

                                       ON                   X

                                       OFF                        MV Always ON
                                                      0

                                                                                                                                                                 37
E5DC

*1 With set values 1, 4, and 5, the upper- and lower-limit values can  *4 Set value: 5, Upper- and lower-limit with standby sequence
     be set independently for each alarm type, and are expressed as         For Upper- and Lower-Limit Alarm Described Above at *2
     "L" and "H."                                                            In cases 1 and 2 above, the alarm is always OFF if the upper-

*2 Set value: 1, Upper- and lower-limit alarm                                   and lower-limit hysteresis overlaps.

    Case 1     Case 2        Case 3 (Always OFF)                            In case 3, the alarm is always OFF.

    L H SP     SP L H          H SP L              H<0, L<0            *5 Set value: 5, Upper- and lower-limit alarm with standby sequence
                             H L SP                                         The alarm is always OFF if upper- and lower-limit hysteresis
    H<0, L>0    H>0, L<0                          H<0, L>0                  overlaps.
    |H| < |L|    |H| > |L|                         |H|  |L|
                                                   H>0, L<0            *6 Refer to the E5@C Digital Temperature Controllers User's Manual
                             SP H L                 |H|  |L|                (Cat. No. H174) for information on the operation of the standby
                                                                            sequence.
*3 Set value: 4, Upper- and lower-limit range     H<0, L<0
                                                  H<0, L>0             *7 Refer to the E5@C Digital Temperature Controllers User's Manual
    Case 1     Case 2        Case 3 (Always ON)    |H|  |L|                 (Cat. No. H174) for information on the LBA.
                                                  H>0, L<0
     L H SP    SP L H          H SP L              |H|  |L|            *8 Refer to the E5@C Digital Temperature Controllers User's Manual
                             H L SP                                         (Cat. No. H174) for information on the PV change rate alarm.
    H<0, L>0     H>0, L<0
    |H| < |L|     |H| > |L|                                            *9 When heating/cooling control is performed, the MV absolute-
                                                                            value upper-limit alarm functions only for the heating operation
                             SP H L                                         and the MV absolute-value lower-limit alarm functions only for the
                                                                            cooling operation.

38
                                                                                                                                   E5DC

Characteristics

Indication accuracy                 Thermocouple:*1 (0.3 % of PV or 1C, whichever is greater) 1 digit max.
(when mounted individually, ambi-
ent temperature of 23C)            Platinum resistance thermometer: (0.2 % of PV or 0.8C, whichever is greater) 1 digit max.

                                    Analog input:    0.2% FS 1 digit max.

                                    CT input:        5% FS 1 digit max.

Influence of temperature *2         Thermocouple input (R, S, B, W, PL II): (1% of PV or 10C, whichever is greater) 1 digit max.
Influence of voltage *2             Other thermocouple input: (1% of PV or 4C, whichever is greater) 1 digit max. *3
                                    Platinum resistance thermometer: (1% of PV or 2C, whichever is greater) 1 digit max.
                                    Analog input: 1% FS 1 digit max.
                                    CT input: 5% FS 1 digit max.

Installation influence (E5DC only)  R, S, B, W, or PLII thermocouple: (1% of PV or 10C, whichever is greater) 1 digit max.
                                    Other thermocouple: (1% of PV or 4C, whichever is greater) 1 digit max. *3

Input sampling period               50 ms

Hysteresis                          Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                    Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

Proportional band (P)               Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                    Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I)                   0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D)                 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Proportional band (P) for cooling   Temperature input: 0.1 to 999.9C or F (in units of 0.1C or F)
                                    Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I) for cooling       0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D) for cooling     0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Control period                      0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)

Manual reset value                  0.0% to 100.0% (in units of 0.1%)

Alarm setting range                 -1,999 to 9,999 (decimal point position depends on input type)

Influence of signal source resis-   Thermocouple: 0.1C/ max. (100  max.), Platinum resistance thermometer: 0.1C/ max. (10  max.)
tance

Insulation resistance               20 M min. (at 500 VDC)

Dielectric strength                 2,300 VAC, 50/60 Hz for 1 min between terminals of different charge

                 Malfunction        10 to 55 Hz, 20 m/s2 for 10 min each in X, Y and Z directions
Vibration                           10 to 55 Hz, 20 m/s2 for 2 hr each in X, Y, and Z directions

                 Resistance

Shock       Malfunction             100 m/s2, 3 times each in X, Y, and Z directions
            Resistance              300 m/s2, 3 times each in X, Y, and Z directions

Weight                              Controller: Approx. 120 g

Degree of protection                Main unit: IP20, Terminal unit: IP00

Memory protection                   Non-volatile memory (number of writes: 1,000,000 times)

Setup Tool                          CX-Thermo version 4.6 or higher

Setup Tool port                     E5DC bottom panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect a USB port on the
                                    computer. *5
                                    E5DC front panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion Cable are
                                    used together to connect a USB port on the computer.*5

                 Approved standards UL 61010-1, CSA C22.2 No. 611010-1 (evaluated by UL), Korean Radio Waves Act (Act 10564)
Standards

                 Conformed standards EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II

                                    EMI:                                              EN61326

                                    Radiated Interference Electromagnetic Field Strength: EN55011 Group 1, class A

                                    Noise Terminal Voltage:                           EN55011 Group 1, class A

                                    EMS:                                              EN61326

EMC                                 ESD Immunity:                                     EN61000-4-2

                                    Electromagnetic Field Immunity:                   EN61000-4-3

                                    Burst Noise Immunity:                             EN61000-4-4

                                    Conduction Disturbance Immunity:                  EN61000-4-6

                                    Surge Immunity:                                   EN61000-4-5

                                    Voltage Dip/Interrupting Immunity:                EN61000-4-11

*1 The indication accuracy of K thermocouples in the -200 to 1,300C range, T and N thermocouples at a temperature of -100C or less, and U
     and L thermocouples at any temperature is 2C 1 digit max. The indication accuracy of B thermocouples at a temperature of 400C max. is
     not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800C is 3C max.
     The indication accuracy of R and S thermocouples at a temperature of 200C max. is 3C 1 digit max. The indication accuracy of W
     thermocouples is (0.3% of PV or 3C, whichever is greater) 1 digit max.
     The indication accuracy of PLII thermocouples is (0.3% of PV or 2C, whichever is greater) 1 digit max.

*2 Ambient temperature: -10 to 23 to 55C, Voltage range: -15% to 10% of rated voltage
*3 K thermocouple at -100C max: 10C max.
*4 The unit is determined by the setting of the Integral/Derivative Time Unit parameter.

*5 External serial communications (RS-485) and USB-Serial Conversion Cable communications can be used at the same time.

                                                                                                                                      39
E5DC

USB-Serial Conversion Cable                                                      Communications Functions
Specifications
                                                                                                                              You can use the memory in the PLC to read and write
    Applicable OS           Windows 2000, XP, Vista, or 7                        Programless                                  E5@C parameters, start and stop operation, etc.
    Applicable software     CX-Thermo version 4.6 or higher                      communications *                             The E5@C automatically performs communications
    Applicable models       E5@C Series and E5CB Series                                                                       with the PLC. No communications programming is re-
    USB interface stan-                                                                                                       quired.
    dard                    Conforms to USB Specification 2.0                                                                 Number of connected Digital Temperature Controllers:
    DTE speed                                                                                                                 32 max.
                            38,400 bps                                                                                        Applicable PLCs: OMRON PLCs
    Connector               Computer: USB (Type A plug)
    specifications          Digital Temperature Controller: Special serial con-                                                          SYSMAC CS Series, CJ Series, or CP Series
                            nector                                                                                                Mitsubishi Electric PLCs
    Power supply            Bus power (supplied from the USB host controller) *
    Power supply voltage    5 VDC                                                                                                        MELSEC Q Series or L Series
    Current consumption     450 mA max.
                            4.70.2 VDC (Supplied from USB-Serial Conver-        Communications                               When Digital Temperature Controllers are connected,
    Output voltage          sion Cable to the Digital Temperature Controller.)   between                                      the parameters can be copied from the Digital Temper-
                            250 mA max. (Supplied from USB-Serial Conver-        components *                                 ature Controller that is set as the master to the Digital
    Output current          sion Cable to the Digital Temperature Controller.)                                                Temperature Controllers that are set as slaves.
                                                                                                                              Number of connected Digital Temperature Controllers:
    Ambient operating       0 to 55C (with no condensation or icing)                                                         32 max. (including master)
    temperature
    Ambient operating       10% to 80%                                                                                        When Digital Temperature Controllers are connected,
    humidity                                                                                                                  set points and RUN/STOP commands can be sent from
    Storage temperature     -20 to 60C (with no condensation or icing)                                                       the Digital Temperature Controller that is set as the
    Storage humidity        10% to 80%                                                                                        master to the Digital Temperature Controllers that are
    Altitude                2,000 m max.                                                                                      set as slaves.
    Weight                  Approx. 120 g                                                                                     Slope and offsets can be set for the set point.
                                                                                                                              Number of connected Digital Temperature Controllers:
                                                                                                                              32 max. (including master)

                                                                                 MELSEC is a registered trademark of Mitsubishi Electric Corporation.

                                                                                 * A Digital Temperature Controller with version 1.0 or higher is required.

                                                                                 Current Transformer (Order Separately)
                                                                                 Ratings

Windows is a registered trademark of Microsoft Corporation in the United         Dielectric strength                                   1,000 VAC for 1 min
States and other countries.                                                      Vibration resistance
                                                                                 Weight                                                50 Hz, 98 m/s2
* Use a high-power port for the USB port.
                                                                                 Accessories (E54-CT3 only)                            E54-CT1: Approx. 11.5 g,
Note: A driver must be installed on the computer. Refer to the                                                                         E54-CT3: Approx. 50 g
        Instruction Manual included with the Cable for the installation
        procedure.                                                                                                                     Armatures (2)
                                                                                                                                       Plugs (2)

Communications Specifications                                                    Heater Burnout Alarms and SSR Failure
                                                                                 Alarms
    Transmission line connection  RS-485: Multidrop
    method

    Communications                RS-485 (two-wire, half-duplex)                 CT input (for heater current Models with detection for single-phase heat-

    Synchronization method        Start-stop synchronization                     detection)                                            ers: 1 input

    Protocol                      CompoWay/F or Modbus                           Maximum heater current                                50 A AC

    Baud rate                     9,600, 19,200, 38,400, or 57,600 bps           Input current                                         5% FS 1 digit max.
                                                                                 indication accuracy

    Transmission code             ASCII                                          Heater burnout alarm                                  0.1 to 49.9 A (in units of 0.1 A)
                                                                                 setting range *1                                      Minimum detection ON time: 100 ms *3
    Data bit length *             7 or 8 bits

    Stop bit length *             1 or 2 bits                                    SSR failure alarm setting                             0.1 to 49.9 A (in units of 0.1 A)
                                                                                 range *2                                              Minimum detection OFF time: 100 ms *4
                                  Vertical parity (none, even, or odd)
    Error detection               Block check character (BCC)                    *1 For heater burnout alarms, the heater current will be measured when the
                                  with CompoWay/F or                                  control output is ON, and the output will turn ON if the heater current is
                                  CRC-16 with Modbus                                  lower than the set value (i.e., heater burnout detection current value).

    Flow control                  None                                           *2 For SSR failure alarms, the heater current will be measured when the
                                                                                       control output is OFF, and the output will turn ON if the heater current is
    Interface                     RS-485                                               higher than the set value (i.e., SSR failure detection current value).

    Retry function                None                                           *3 The value is 30 ms for a control period of 0.1 s or 0.2 s.
                                                                                 *4 The value is 35 ms for a control period of 0.1 s or 0.2 s.

    Communications buffer         217 bytes

    Communications response       0 to 99 ms                                     Electrical Life Expectancy Curve for
    wait time                     Default: 20 ms                                 Control Output Relay (Reference Values)

* The baud rate, data bit length, stop bit length, and vertical parity can       Life ( 104 operations)  500
  be individually set using the Communications Setting Level.                                             300

                                                                                                          100

                                                                                                           50
                                                                                                           30

                                                                                                          10

                                                                                                          5       E5DC

                                                                                                          3       250 VAC, 30 VDC

                                                                                                                  (resistive load)

                                                                                                                  cos = 1

                                                                                                          1

                                                                                                               0  1        2        3  4        5    6

                                                                                                                                       Switching current (A)

40
                                                                                                                                                  E5DC

External Connections

E5DC                                   Auxiliary outputs 1 and 2      The E5DC is set for a K-type thermocouple (input type = 5) by default.
                                                                      An input error (s.err) will occur if the input type setting does not agree
           Control output          Relay outputs                      with the temperature sensor. Check the input type.
                                    250 VAC: 2 A (resistive load)
  Relay output
   250 VAC, 3 A (resistive load)                                                     E5DC

Voltage output (for driving SSR)                                                          Control output      Options
   12 VDC, 21 mA
                                   Input Power Supply                                Control Output
Linear current output             100 to 240 VAC 24 VAC/DC
   0 to 20 mA DC
   4 to 20 mA DC
   Load: 500  max.

                                             1           1                                  RX                QX              CX

                                                                                           1 relay     1 voltage output   1 linear
                                                                                           output      (for driving SSR)  current output

                                             2           2                           5              R       5  +  Q       5         +  C
                                                                                     6                      6  -          6         -
                                                    (no polarity)

                                   Options                            159                              Auxiliary Outputs
                                                                      2 6 10                              9 Auxiliary output 2
                                   002                                                                   10 Auxiliary output 1
                                   Communications and 1 CT                       11                      11

                                   B(+)

                                   RS-485    3                     7

                                             4      CT1            8

                                   A(-)

                                   015                                                              Sensor (Temperature/Analog) Input

                                   Communications                                                      TC         Pt             I        V
                                                                                                               A
                                   B(+)                            7                                    12                  + 12          12
                                                                                                    - 13           12     mA 13       - 13
                                   RS-485    3                                   12                            B                    V 14
                                                                      3 7 13                        + 14                     -        +
                                             4                     8  4 8 14                                       13           14
                                                                                                               B
                                   A(-)
                                                                                                                   14

                                   016                                                              Do not connect anything to the terminals
                                   One event input                                                  that are shaded gray.

                                   -         3                     7

                                   +    EV1  4                     8

                                   017
                                   One event input and one CT

                                   -            3                  7

                                   +                CT1            8

                                        EV1     4

Note: 1. The application of the terminals depends on the model.
        2. Do not wire the terminals that are shown with a gray background.
        3. When complying with EMC standards, the cable that connects the sensor must be 30 m or less. If the cable length exceeds 30m,
            compliance with EMC standards will not be possible.
        4. Connect M3 crimped terminals.

Isolation/Insulation Block Diagrams

Power                       Sensor input and CT input
supply                   Communications and event input
        Voltage output (for driving SSR) and linear current output

                                      Relay output
                              Auxiliary outputs 1 and 2

                             : Reinforced insulation
                             : Functional isolation

Note: Auxiliary outputs 1 to 2 are not insulated.

                                                                                                                                                  41
E5DC                                                  Front panel
Nomenclature

E5DC

                                                                         No. 1 display                                                         Bottom View of E5DC
                                                                       PV or specified parameter
              Operation indicators
                                                                         No.2 display
             Press O Key once to go to                                 SP or specified parameter value
             Adjustment Level.
                                                                         Use the M Key to change to another
                                                                         parameter.

                    Press O Key for at least 3                               Use the U D Keys to              Bottom-
                    seconds to go to Initial                                 set the parameter.               panel Setup
                    Setting Level.                                                                            Tool port

    Use S Key to change the digit (default setting).                         Front-panel Setup Tool port

Dimensions                                                                                                                                                          (Unit: mm)

Controllers                                    4                             (85)
                        22.5                                                   81
E5DC
                                                                                                                                         22.5

              96                                                                       35 110             91

                                                                                       4

                                            Mounting Adapter
                                             (Accessory: Sold separately)

              The Setup Tool port is on the bottom of the Temperature Controller.
              It is used to connect the Temperature Controller to the computer to use the Setup Tool.
              The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection.
              Refer to the instructions that are provided with the USB-Serial Conversion Cable for the
              connection procedure.

              Note: Do not leave the USB-Serial Conversion Cable connected when you use
                      the Digital Temperature Controller.

              Mounted Separately                                   Two-Unit Mounting              Group Mounted

                                                      22.7  +0.3                 +0.6             (22.5 number of units) +1.0
                                                            0                    0                                                         0

                                                                             45

              92  +0.8                                             92  +0.8            92  +0.8
                  0                                                    0                   0

                                                      120 min

               Recommended panel thickness is 1 to 8 mm.
               Group mounting is not possible in the vertical direction. (Maintain the specified mounting space between Controllers.)
               When two or more Digital Temperature Controllers are mounted, make sure that the surrounding temperature does

                not exceed the allowable operating temperature specified in the specifications.
               To attach the USB-Serial Conversion Cable to the control panel, use a panel thickness of 1 to 2.5 mm.

42
Accessories (Order Separately)                                                                                                                                                                                    E5DC

USB-Serial Conversion Cable                                                                                                                        (2110)                                                  1510
                                                                                                                                                                                   263                                 Serial connector
E58-CIFQ2                                                                           250
                                                                                                                               LED (RD)                                                                      1510

                                                                     USB connector
                                                                     (type A plug)

                                                                                                                                                               LED (PWR)
                                                                                                                                                               LED (SD)

Conversion Cable                                                          Connecting to the E58-CIFQ2 USB-Serial Conversion Cable
E58-CIFQ2-E
                                                                                                                                                               (2110)
           Conversion Cable
                                                                                                    250                                                                     263
                                          (1510)

Note: Always use this product together with the E58-CIFQ2.                                                                     E58-CIFQ2 (sold separately)                                          Conversion Cable

Current Transformers                                                      21                                                  Thru-current (Io) vs. Output Voltage (Eo) (Reference Values)
E54-CT1                                                                    15
                                                                                                            2.8                E54-CT1
                                                               25 3                       5.8 dia.                     7.5

                                                                                                                               Maximum continuous heater current: 50 A (50/60 Hz)

                                                                                                                               Number of windings:                                                4002

                                                                                                                               Winding resistance:                                                182

                                                                                                                               Output voltage (Eo) V (r.m.s.)  100V Frequency: 50 Hz

                                                                                                    10.5                                                             10                             Distortion
                                                                                                                                                                      1
                                                                           40                                                                                               1k                      factor
                                                                                             Two, 3.5 dia.                                                     100mV
                                                                                                                                                                                                    10%

                                                   10                                                                                                                                                   3%
                                            40 40                                                                                                                                                 1%

                                                                       30                                                                                      10                          100

E54-CT3                                                                                                 2.36 dia.
                                                                     30
                                                                                                                                                               1                           RL=10
                                                                                      12 dia.
                                                                                                                            9

                                                                                                                                                               100V

                                                                                                                                                               10

                                                                                                                                                                         1  10 100mA 1          10  100 1,000A

                                                                                                                                                                                           Thru-current (Io) A (r.m.s.)

                                                                                                                               Thru-current (Io) vs. Output Voltage (Eo) (Reference Values)

                                                                                     Two , M3 holes (depth: 4)                 E54-CT3
                                                  15
                                                                                                                               Maximum continuous heater current: 120 A (50/60 Hz) (Maximum
                                                                          30                                                   continuous heater current for an OMRON Digital Temperature Con-
                                                                                                                               troller is 50 A.)
E54-CT3 Accessories
Armature                                                                                                                     Number of windings: 4002

  Approx. 3 dia.                                                                                                               Winding resistance: 80.8

                                                  Connection Example                                                           Output voltage (Eo) V (r.m.s.)  100V Frequency: 50 Hz

                                                                                    Armature                                                                   10                                              Distortion
                                                                                                                                                                            1k                                 factor
                                                                                                                                                                                                               10%
                                                                     Plug                                                                                                   500                               3%
                                                                                                                                                                                                            1%
                                                                                                                                                               1

                                                                                                    Lead

                                        18                                                                                                                     100mV                        100
                                                                                                                                                                     10                    50
Plug                                                                                                                                                                1
                                                                                                                                                                                           RL=10

Approx. 6 dia.                                                                                                                                                 100V         10 100mA    1       10  100 1,000A
                                  (22)                                                                                                                               10
                                                                                                                                                                        1

                                                                                                                                                                                           Thru-current (Io) A (r.m.s.)

                                                                                                                                                                                                                           43
E5DC                                                                                                                        Short Bars
                                                                                                                           Y92S-P11 (Four included.)
  Mounting Adapters
Y92F-53 (Two included.)                                                                                                   Use this product to connect between terminals (for power supplies,
                                                                                                                           communications, etc.) when you use multiple E5DC Controllers.
This accessory is not included with the
product. Order it separately to mount                                                                                                                                                 27.5
the product to a panel.
                                                                                                                                                                  2.4                 22.5
                                                                                                 34.7

                                                                        12

                                                                                                                                                                       24.8

                11.8 9.4                                                                                                                                          0.8                            3

                                                                                                                                                                                                 5

     End Plate                                                                                                              DIN Tracks
    PFP-M                                                                                                                  PFP-100N
                                                                                                                           PFP-50N
     Spacer
    PFP-S                                 10
                                                 6.2
                                                           1.8

                   M48                                                                                1
                   pan head                                                                                     35.5 35.3
                   screw
                50                                                                                       1.8

                  11.5                                                                                 1.3                                                                            7.30.15
                                                                                                                                                                                         350.3
                                 10                                                                    4.8                 4.5
                        M4 spring washer

                                                                                                                                                                                                 270.15

                                                                                                                                15 25 10 25               25  10  25         15 (5)*             1

                                                                                                                                             1000 (500)*

                                                                                                                                             * Dimensions in parentheses are for the PFP-50N.

                                                                                                                            Unit Labels
                                                                                                                           Y92S-L2

                                                                                                       16

                          5                                                                            12                                                 The Unit Labels for the Digital Panel
                                                                                                                                                          Meter are used. Use either the C or F
                                                                                                                                                          label from the sheet.

                                                                    34.8
                                          44.3

                                                                                                       16.5

44
MEMO

                                            45
E5CC/E5EC/E5AC/E5DC

Operation

Setting Levels Diagram

This diagram shows all of the setting levels. To move to the advanced function setting level and calibration level, you must enter passwords. Some
parameters are not displayed depending on the protect level setting and the conditions of use.
Control stops when you move from the operation level to the initial setting level.

               Only when Manual Mode was                                          Press the O and M          Protect Level
               used just before power OFF
                                                                                  Keys for at least 1 s.    Used to set protection
                    Press the O Key or the                                                                       for operations.
                     S Key for at least 1 s.                   Power ON
                                                                                                                      Press the O and M Keys
                                                     Level changes
                                                     automatically.                                                        for at least 3 s.*2

    Operating  Manual Control                         Operation Level             O Key once.             Adjustment Level
                      Level
                                                     Used for SP, alarm values,                         Used to change adjustment
                    Used to set the                  and other basic settings                           parameters (PID constants,
                    MV manually.                     and monitoring.
                                                                                  O Key once. adjustment sensitivity, etc.).

               O Key pressed for at least 3 s *2

               or S Key pressed for at least 1 s *1

               while A-M is displayed

                                     Press the O Key                     Press the O Key

                                     for at least 3 s.*2                 for at least 1 s.

                                                     Initial Setting Level         Press O Key once

                                                      Used to set the input type    (models with communications only).
                                                      and other basic settings.
                                                                                                    Communications
                                                                                                       Setting Level

                                                                                  O Key once. Used to set communications.

    Stopped.   Release protection and then                               Press the O Key for at least 1 s.
               enter the password (-169)
               for the amoV (Move to Advanced
               Setting Level) parameter.

                                                     Advanced Function
                                                         Setting Level

                                                       Used to set application
                                                                 functions.

                                     Enter the password
                                     (1201) for the Move to
                                     Calibration Level parameter.

                                                              Calibration Level

*1. To use a key procedure to move to Manual Control Level, set the Auto/Manual Select Addition parameter to ON and set the PF Setting parameter to a-m (Auto/
      Manual).

*2. The No. 1 display will flash in the middle when the keys are pressed for 1 s or longer.

46
                                                                                       E5CC/E5EC/E5AC/E5DC

Error Displays (Troubleshooting)

When an error occurs, the No. 1 display or No. 2 display shows the error code.
Take necessary measure according to the error code, referring the following table.

Display  Name                             Meaning                                  Action                                 Operation

s.err Input error       The input value exceeded the control    Check the wiring for input to be sure    After the error occurs and it is
                        range.*                                 it is wired correctly, not broken, and   displayed, the alarm output will
                        The input type is not set correctly.    not shorted. Also check the input        operate as if the upper limit was
                        The sensor is disconnected or short-    type.                                    exceeded.
                        circuited.                              If there are no problems in the wiring   It will also operate as if transfer
                        The sensor is not wired correctly.      or input type settings, cycle the        output exceeded the upper limit.
                        The sensor is not wired.                power supply.                            If an input error is assigned to a
                                                                If the display remains the same,         control output or auxiliary output, the
                        * Control Range                         replace the Digital Temperature          output will turn ON when the input
                        Temperature resistance                  Controller.                              error occurs.
                        thermometer or thermocouple input:      If the display is restored to normal,    The error message will appear in the
                                                                then the probable cause is external      display for the PV.
                          SP Lower Limit - 20C to SP Upper     noise affecting the control system.
                          Limit + 20C                          Check for external noise.                Note: 1. The heating and cooling
                          (SP Lower Limit - 40F to SP Upper                                                         control outputs will turn
                          Limit + 40F)                         Note: For a temperature resistance                   OFF.
                        ESIB input:                                     thermometer, the input is
                          Same as specified input range.                considered disconnected if               2. When the manual MV, MV
                        Analog input:                                   the A, B, or B' line is broken.              at stop, or MV at error is
                          Scaling range -5% to 105%                                                                  set, the control output is
                                                                                                                     determined by the set
                                                                                                                     value.

                                      This is not an error. It

[[[[     Display        Below -1,999  is displayed when the                         -                    Control continues and operation is
]]]]     range          Above 9,999   control range is wider                                             normal.
         exceeded                     than the display                                                   The value will appear in the display
                                      range and the PV                                                   for the PV.
                                      exceeds the display                                                Refer to the E5@C Digital
                                      range. The PV is                                                   Temperature Controllers User's
                                      displayed for the                                                  Manual (Cat. No. H174) for
                                      range that is given on                                             information on the
                                      the left (the number                                               controllable range.
                                      without the decimal

                                      point).

e333     A/D            There is an error in the internal       First, cycle the power supply.           The control outputs, auxiliary
         converter      circuits.                               If the display remains the same, the     outputs, and transfer outputs turn
e111     error                                                  controller must be repaired.             OFF. (A current output will be approx.
                                                                If the display is restored to normal,    0 mA and a linear voltage output will
ffff     Memory         There is an error in the internal       then a probable cause can be             be approx. 0V.)
         error          memory operation.                       external noise affecting the control
ct1                                                             system. Check for external noise.        The control outputs, auxiliary
ct2      Overcurrent    This error is displayed when the peak   First, cycle the power supply.           outputs, and transfer outputs turn
lcr1                    current exceeds 55.0 A.                 If the display remains the same, the     OFF. (A current output will be approx.
lcr2                                                            controller must be repaired.             0 mA and a linear voltage output will
         HB or HS       If there is a HB or HS alarm, the No.   If the display is restored to normal,    be approx. 0V.)
----     alarm          1 display will flash in the relevant    then a probable cause can be
                        setting level.                          external noise affecting the control     Control continues and operation is
                                                                system. Check for external noise.        normal.
                        "----" will be displayed for the Valve                                           The error message will appear for the
                                                                                       -                 following displays.
                        Opening Monitor parameter if any of                                              Heater Current Value 1 Monitor
                                                                                       -                 Heater Current Value 2 Monitor
                        the following error occurs.                                                      Leakage Current Value 1 Monitor
                                                                Check for the above errors.              Leakage Current Value 2 Monitor
         Potentiometer   Motor calibration has not been                                                 The No. 1 display for the following
         Input Error                                                                                     parameter flashes in Operation Level
         (Position-       performed.                                                                     or Adjustment Level.
                         The wiring of the potentiometer is                                             Heater Current Value 1 Monitor
                                                                                                         Heater Current Value 2 Monitor
         proportional   incorrect or broken.                                                             Leakage Current Value 1 Monitor
                                                                                                         Leakage Current Value 2 Monitor
         Models Only) The potentiometer input value is                                                 However, control continues and
                                                                                                         operation is normal.

                                                                                                         Close control: The control output is
                                                                                                         OFF or the value that is set for the
                                                                                                         MV at PV Error parameter is output.
                                                                                                         Floating control: Operation will be
                                                                                                         normal.

                        incorrect (e.g., the input is out of

                        range or the potentiometer has

                        failed).

                                                                                                                                                  47
E5CC/E5EC/E5AC/E5DC

Operation

Parameters

The related setting items in each level are described below. If you press the Mode Key at the last setting item, the display will return to the first
setting item in the same level.

                                                                                                                    Power ON                                                                                                                                                                                            S Key*2

                                                                            Starting in Manual Mode.                                                                         Starting in             Press the O Key for at least 3 s.                                                                                                   S Key*2
                                                                                                                                                                             Automatic
                                                                                         Manual Control Level                                                                Mode.                   Other than the Auto/Manual Switch display

                                            Press the S Key                                                                       Press the O                                                                                                                                                            Initial Setting Level
                                            for at least 1 s.
                                                                                                        C  25       PID           Key or the S                                                                                                                                                           Press the         Press the O Key for less than 1 s.
                                                             *1                                                     Control                                                                                                                                                                              O Key for
                                                                                                           0 only                 Key for at least                                                                                                                                                       at least 1 s.       in-t Input Type
                                      Press the O Key less than 1 s.                                                                                                                                                                                                                                                                       5
                                                                                                        PV/MV                     1 s.            *1                                                                                                                                                                             M
                                        Press the O Key less than 1 s.
    Adjustment                                                                                                                             Operation Level                                                                                                                                                                   in-h Scaling Upper Limit
    Level                                                                                                                                                                                                                                                                                                                              100

                   Adjustment Level                                                                                 25 Process Value/                                        al1h Alarm Value                                                                                                                                  M
                   Display                                                                                             0 Set Point 1                                         0            Upper Limit                                                                                                                      in-l Scaling Lower Limit
                   Displayed only     ins Process Value Input                orl MV Change Rate                                                                                           1
                                           0.0 Shift                                      Limit                      M                                                                                                                                                                                                                0
    l.adj once when                      M                                             0                            25 Process Value/                                        M
                   entering                                                     M                                                                                                                                                                                                                                          M
                   adjustment level.  inrt Process Value Slope                 db Position                             0 Set Point 2                                         al1l Alarm Value                                                                                                                              dp Decimal Point
                                           1.000 Coefficient                              Proportional                                                                                     Lower Limit
      M                                                                             2.0 Dead Band *4                                                                                   01                                                                                                                                      0 For input type of analog
        at AT Execute/Cancel                                                    M
                                                                                                                         M                                                   M                          Set either of these parameters. Set either of these parameters. Set either of these parameters.                    M
            off                                                             oc-h Open/Close                          a-m Auto/Manual Switch
                                      M                                             0.8 Hysteresis *4                                                                        al-2         Alarm                                                                                                                            d-u Temperature Unit
         M                                                                      M                                                 PID control only.                          0            Value 2                                                                                                                                    C, F
    cmwt Communications                                                                                                           Added when
                                      rss Remote SP Input Shift             sqrp Extraction of          Press the                                                                                                                                                                                                                     c  For input type of
                   Writing                 0.0 *4                                         Square Root   O Key            M auto/manual select
            off                                                                       0 Low-cut Point   for at                    addition is ON.                            M                                                                                                                                             M             temperature
                                                                                M
         M                            M                                                                 least 3 s.  m-sp Multi-SP Set                                        al2h Alarm Value                                                                                                                              sl-h SP Upper Limit
    spmd SP Mode                                                            w1on Work Bit 1                                       Point Selection                                          Upper Limit                                                                                                                           1300
                                      rsrt Remote SP Input                                ON Delay                             0                                                       02
           lsp *4
                                      1.000  Slope Coefficient                  M                                     M                                                           M                                                                                                                                        M             Limit the set point
         M                                   *4                             w1of Work Bit 1                         rsp Remote SP Monitor                                    al2l Alarm Value
      ct1 Heater Current 1
                                      M                                                   OFF Delay                      0.0 *4                                                            Lower Limit                                                                                                                     sl-l SP Lower Limit
                   Value Monitor                                                                                                                                                       02                                                                                                                                        -200
              0.0                     p Proportional Band                       M
                                                                            w2on Work Bit 2                             M                                                    M                                                                                                                                                 M
        M                             8.0                                                                           sp-m Set Point During                                                                                                                                                                                  cntl PID ON/OFF
      hb1 Heater Burnout                                                                  ON Delay
                                      M                                                                                           SP Ramp                                    al-3         Alarm                                                                                                                                  onof
                   Detection 1         i Integral Time                          M                                              0                                             0            Value 3
              0.0                                                           w2of Work Bit 2
                                      233                                                                               M                                                         M                                                                                                                                            M
        M                                                                                 OFF Delay                 ct-1 Heater Current 1 Value                                                                                                                                                                            s-hc Standard or
      ct2 Heater Current 2            M      PID settings                                                                                                                    al3h Alarm Value
                                                                                M                                                 Monitor                                                  Upper Limit                                                                                                                          stnd Heating/Cooling
                   Value Monitor       d Derivative Time                    w3on Work Bit 3                                  0.0                                                       03
             0.0 *4                                                                                                                                                                                                                                                                                                            M
                                       40                                                 ON Delay                      M                                                         M
        M                                                                                                           ct-2 Heater Current 2 Value                              al3l Alarm Value                                                                                                                                 st ST (Self-tuning)
      hb2 Heater Burnout              M                                         M                                                                                                                                                                                                                                                  on For input type of
                                                                            w3of Work Bit 3                                       Monitor                                                  Lower Limit                                                                                                                                       temperature, standard
                   Detection 2                                                                                              0.0 *4                                                     03
             0.0 *4                                                                       OFF Delay                                                                                                                                                                                                                            M control, or PID
                                      c-p Proportional Band                                                             M                                                    M
        M                                  8.0 (Cooling)                        M                                   lcr1 Leakage Current 1                                                                                                                                                                                 ptrn Program Pattern
    lcr1 Leakage Current 1                                                  w4on Work Bit 4                                                                                  al-4         Alarm                                                                                                                                   off When assigning PID or
                                        M                                                                                         Monitor                                    0            Value 4                                                                                                                              M control output to ON/OFF
                   Monitor            c-i Integral Time                                   ON Delay                           0.0                                                                                                                                                                                                        output
              0.0
                                          233 (Cooling)                         M                                       M                                                         M                                                                                                                                        cp Control Period (Heating)
        M                                                                   w4of Work Bit 4                         lcr2 Leakage Current 2                                   al4h Alarm Value
      hs1 HS Alarm 1                    M
                                      c-d Derivative Time                                 OFF Delay                               Monitor                                                  Upper Limit
            50.0                                                                                                            0.0 *4                                                     04
                                           40 (Cooling)                         M
        M                                                                   w5on Work Bit 5                             M                                                         M                                                                                                                                        20            Set the ON/OFF
    lcr2 Leakage Current 2              M                                                                           prst Program Start                                       al4l Alarm Value
                                                                                          ON Delay                                                                                                                                                                                                                         M             output cycle.
                   Monitor                                                                                                rset                                                             Lower Limit
             0.0 *4                   c-db Dead Band                            M                                                                                                      04                                                                                                                                  c-cp Control Period (Cooling)
                                               0.0                          w5of Work Bit 5                             M                                                                                                                                                                                                           20
         M                                                                                                          sktr Soak Time Remain                                         M
      hs2 HS Alarm 2                      M                                               OFF Delay
                                      of-r Manual Reset Value                                                                  0                                             o MV Monitor                                                                                                                                  M
           50.0 *4                                                              M
                                                   Clear the offset during  w6on Work Bit 6                                                                                  0.0 (Heating)                                                                                                                                 orev Direct/Reverse Operation
         M                                  50.0 stabilization of P or PD                                                                                                                                                                                                                                                        or-r
    sp-0 SP 0                                                                             ON Delay                    M                                                         M
                                          M control.                                                                r-s RUN/STOP                                             c-o MV Monitor                                                                                                                                M
                0                      hys Hysteresis (Heating)                 M
                                                                            w6of Work Bit 6                             run                                                             (Cooling)                                                                                                                          alt1 Alarm 1 Type
         M                                     1.0                                                                                                                                 0.0                                                                                                                                                2
    sp-1 SP 1                                                                             OFF Delay
                                          M Hysteresis settings                                                     M                                                          M
                0                     chys Hysteresis (Cooling)                 M                                                                                            v-m Valve Opening
                                                                            w7on Work Bit 7                         al-1          Alarm    Set either of                                                                                                                                                                       M
         M                                     1.0                                                                             0  Value 1  these                                        Monitor *4                                                                                                                         alh1 Alarm 1
    sp-2 SP 2                                                                             ON Delay                                         parameters.                             0.0
                                          M                                                                         M                                                                                                                                                                                                              0.2 Hysteresis
                0                     soak Soak Time                            M                                                                                               M
                                                                            w7of Work Bit 7
         M                                       1                                                                                                                                                                                                                                                                         M
    sp-3 SP 3                                                                             OFF Delay
                                          M                                                                Press the O and M Keys for                                        Press the O and M Keys     Press the O Key
                0                     wt-b Wait Band                            M                          at least 3 s.                                                     for at least 1 s.          less than 1 s.
                                                                            w8on Work Bit 8
         M                                    off                                                                            Protect Level                                   Communications
    sp-4 SP 4                                                                             ON Delay
                                                                                                                                                                             Setting Level
                0                                                               M
                                                                            w8of Work Bit 8                    The time taken to move to the protect level                   Displayed only for models with                                                                                                             * Used with programless communications
         M                                                                                                     can be adjusted by changing the "Move to                      communications. Changes are
    sp-5 SP 5                                                                             OFF Delay            protect level time" setting.                                  effective after cycling power or
                                                                                                                                                                             after a software reset.
                0                                                               M                                   pmov Move to Protect Level:                                                                                                                                                                                          up 1 Upload
                                                                            plcm Communications                     0        Displayed only when a                              psel Protocol Setting:                                                                                                                                             0 Setting 1
         M                            mv-s MV at Stop                                                                        password is set. Restricts                                         Switches between                                                                                         maxu Highest
    sp-6 SP 6                                  0.0                               1234 Monitor                                                                                            cwf CompoWay/F and                                                                                                           Communications
                                          M                                                                         M moving to protect level.                                                  Modbus.                                                                                                            0 Unit No.                      M
                0                                                               M                                                                                                    M                                                                                                                       M *3
                                      mv-e MV at PV Error                                                                    Operation/Adjustment Protect:                                                                                                                                                                               up13          Upload
         M                                     0.0                                                                                                                              u-no Communications                                                                                                      area Area                                  0  Setting 13
    sp-7 SP 7                                                                                                       oapt Restricts displaying and                                               Unit No.                                                                                                            0
                                          M                                                                         0        modifying menus in operation,                                    1
                0                     sprt SP Ramp Set Value                                                                 adjustment, and manual                                                                                                                                                          M                               M
                                                                                                                                                                                     M                                                                                                                   adrh First Address              dn 1 Download
         M                                    off                                                                   M control levels.                                            bps Communications
                                                                                                                    icpt Initial Setting/Communications Protect:                                                                                                                                                   0 Upper Word                    0 Setting 1
                                          M                                                                                        This protect level restricts movement to                     Baud Rate
                                      sprl SP Ramp Fall Value                                                       1 the initial setting, communications setting,                        9.6 CompoWay/F                                                                                                     M
                                                                                                                                                                                                                                                                                                                                             M
                                            same                                                                    M and advanced function setting levels.                          M only                                                                                                                                              dn13 Download

                                          M                                                                         wtpt Setting Change Protect:                                                                                                                                                                                              1000 Setting 13
                                                                                                                    off      Protects changes to setups by
                                      ol-h MV Upper Limit                                                                    operating the front panel keys.                 len Communications                                                                                                          adrl First Address
                                           100.0                                                                                                                                    7 Data Length                                                                                                                  0 Lower Word              M
                                                                                                                    M                                                          M                                                                                                                             M                           copy Copy
                                          M
                                      ol-l MV Lower Limit                                                           pfpt PF Key Protect                                                                                                                                                                                                       off *3
                                                                                                                            off
                                               0.0                                                                                                                           sbit Communications                                                                                                         rwat Receive Data
                                                                                                                    M                                                                      Stop Bits                                                                                                     1000              Wait Time
                                          M                                                                                                                                             2                                                                                                                                  *3                          SP Slope
                                                                                          &nbs