电子工程世界电子工程世界电子工程世界

型号

产品描述

搜索

E2E2-X2Y1

器件型号:E2E2-X2Y1
器件类别:传感器   
文件大小:4268.84KB,共10页
厂商名称:OMRON
厂商官网:https://www.omron.com
下载文档

器件描述

Proximity Sensors PROX LONG M12 2mm AC2W-NO 2M

参数

产品属性属性值
产品种类:
Product Category:
Proximity Sensors
制造商:
Manufacturer:
Omron
RoHS:No
Sensing Method:Inductive
Sensing Distance:2 mm
安装风格:
Mounting Style:
Panel
Output Configuration:NO
最大工作温度:
Maximum Operating Temperature:
+ 85 C
最小工作温度:
Minimum Operating Temperature:
- 40 C
商标:
Brand:
Omron Automation and Safety
Description/Function:NO
高度:
Height:
21 mm
长度:
Length:
70 mm
系列:
Series:
E2E2
工厂包装数量:
Factory Pack Quantity:
1
宽度:
Width:
21 mm
单位重量:
Unit Weight:
2.292808 oz

E2E2-X2Y1器件文档内容

                   R

Long Barrel Inductive Prox                                                       E2E2  2-WIRE          AC

Rugged Inductive Prox Sensors

Meet IP67 Requirements

H  Solid potted internal circuitry withstands

   shocks and water washdown to IP67

H  Thick nickel-plated brass barrel has

   wrench flats for easy installation

H  High visibility indicator

H  Connector and prewired versions

Ordering Information

J PRE-WIRED  SENSORS

Type         Size             Sensing distance                   Part number

                                                                 NO                    NC

Shielded     M12              2  mm                              E2E2-X2Y1-US          E2E2-X2Y2-US

             M18                 5 mm                            E2E2-X5Y1-US          E2E2-X5Y2-US

             M30                     10           mm             E2E2-X10Y1-US         E2E2-X10Y2-US

Unshielded   M12                 5 mm                            E2E2-X5MY1-US         E2E2-X5MY2-US

             M18                     10           mm             E2E2-X10MY1-US        E2E2-X10MY2-US

             M30                                      18  mm     E2E2-X18MY1-US        E2E2-X18MY2-US

J SENSORS   WITH CONNECTORS

Type         Size             Sensing distance                   Part number

                                                                 NO                    NC

Shielded     M12              2  mm                              E2E2-X2Y1-M4          E2E2-X2Y2-M4

             M18                 5 mm                            E2E2-X5Y1-M4          E2E2-X5Y2-M4

             M30                     10           mm             E2E2-X10Y1-M4         E2E2-X10Y2-M4

Unshielded   M12                 5 mm                            E2E2-X5MY1-M4         E2E2-X5MY2-M4

             M18                     10           mm             E2E2-X10MY1-M4        E2E2-X10MY2-M4

             M30                                      18  mm     E2E2-X18MY1-M4        E2E2-X18MY2-M4

Note:  Connector cordsets, use OMRON Y96E-33VAV.

                                                              2
E2E2 2-WIRE AC                                                                                                                  E2E2 2-WIRE AC

J  ACCESSORIES

Description                                                                                                  Part number

Mounting brackets                                Fits  M12 size sensors                                      Y92E-B12

                                                 Fits  M18 size sensors                                      Y92E-B18

                                                 Fits  M30 size sensors                                      Y92E-B30

Silicone rubber covers for shielded sensors      Fits  M12 size sensors                                      Y92E-E12-2

                                                 Fits  M18 size sensors                                      Y92E-E18-2

                                                 Fits  M30 size sensors                                      Y92E-E30-2

Connector cordsets                               See   Y96E Connector Cordsets       data        sheet  for  details

J  REPLACEMENT PARTS

Description                                                                                                  Part number

Mounting hardware including one pair of          Fits  M12 size sensors                                      M12-MHWS

metal nuts and one washer                        Fits  M18 size sensors                                      M18-MHWS

                                                 Fits  M30 size sensors                                      M30-MHWS

Specifications

Part number                     E2E2-X2Yj-US     E2E2-X5Mj-US        E2E2-X5Yj-US                E2E2-X10MYj-US       E2E2-X10j-US        E2E2-X18MYj-US

Size                            M12                                  M18                                              M30

Type                            Shielded         Unshielded          Shielded                    Unshielded           Shielded            Unshielded

Sensing distance                2 mm (0.08 in)   5 mm (0.20 in)      5 mm (0.20 in)              10 mm (0.39 in)      10 mm (0.39         18 mm (0.71 in)

                                ±10%             ±10%                ±10%                        ±10%                 in) ±10%            ±10%

Supply voltage (operating       24 to 240 VAC, 50/60 Hz (20 to 264 VAC)

voltage range)

(See Note 1.)

Leakage current                 1.7 mA max.

Sensing object                  Magnetic metals

Setting distance                0 to 1.6 mm      0 to 4.0 mm         0 to 4.0 mm                 0 to 8.0 mm          0 to 8.0 mm         0 to 14.0 mm

                                (0 to 0.06 in)   (0 to 0.16 in)      (0 to 0.16 in)              (0 to 0.31 in)       (0 to 0.31 in)      (0 to 0.55 in)

Standard object (mild steel)    12 x 12 x        15 x 15 x           18 x 18 x                   30 x 30 x 1 mm       30 x 30 x           54 x 54 x 1 mm

                                1 mm (0.47 x     1 mm (0.59 x        1 mm (0.71 x                (1.18 x 1.18 x       1 mm (1.18 x        (2.13 x 2.13 x

                                0.47 x 0.04 in)  0.59 x 0.04 in)     0.71 x 0.04 in)             0.04 in)             1.18 x 0.04 in)     0.04 in)

Differential travel             10% max. of sensing distance

Response frequency              25 Hz

Operation (with sensing         Y1 models: Load ON

object approaching)             Y2 models: Load OFF

Control output (switching       5 to 200 mA                          5 to 300 mA (see note 2)

capacity)

Indicator                       Operation indicator (red LED)

Ambient              Operating  --40°C to 85°C (--40°F to 185°F) with no icing

temperature

Ambient              Operating  Operating: 35% to 95%

humidity

Temperature influence           ±15% max. of sensing distance at 23°C in temperature range of --40°C                  to 85°C (--40°F to  185°F)

                                ±10% max. of sensing distance at 23°C in temperature range of --25°C                  to 70°C (--13°F to  158°F)

Voltage influence               ±1% max. of sensing distance in rated voltage range ±15%

Residual voltage                Refer to Engineering Data

Insulation resistance           50 MΩ min. (at 500 VDC) between current carry parts and case

Dielectric strength             4,000 VAC for 1 min. between current carry parts and case

Vibration resistance            10 to 55 Hz, 1.5-mm double amplitude for 10 times each in X, Y, and Z                 axes

                                                       (This table continues on the next page.)

                                                                  3
E2E2 2-WIRE AC                                                                                                   E2E2 2-WIRE AC

Specifications Table     --   continued from previous page

Part number                    E2E2-X2Yj-US     E2E2-X5Mj-US   E2E2-X5Yj-US           E2E2-X10MYj    -US  E2E2-X10j-US  E2E2-X18MYj-US

Shock resistance               1,000 m/s2 (approx. 100G) for 10 times each in X,  Y, and Z axes

Enclosure    IEC               IP67

rating       NEMA              1, 4, 6, 12, 13

Weight                         65 g                            150 g                                      220 g

Approvals    UL                Recognized, File Number E76675

             CSA               Certified, File Number LR45951

Material     Body              Brass

             Sensing  face     PBT

Note: 1.  When using an M18 or M30 size E2E2 at an ambient     temperature between 70°C and 85°C (158°F to 185°F), make sure the

          E2E2 has a control output of 200 mA maximum.

      2.  When supplying 24 VAC to any of the above models,    make sure that the operating ambient temperature range is --25°C to 85°C

          (--13°F to 185°F).

Operation

J  OUTPUT CIRCUIT                                                     J  TIMING CHART

                               Brown 1 (or 3)                                              Yes

                               Load                                   Sensing object       No

                                                                      Control output       ON

Main                                                                                       OFF
circuit
                                                                                           Lit
                                                                      Red indicator
                                                                                           Not lit

                               Blue 2 (or 4)

Engineering Data

J OPERATING RANGE (TYPICAL)

Shielded Models E2E2-XjYj

             Sensing distance                                                     Sensing  distance
             X (mm)                                                               X (mm)

                                                                                                     E2Ej-X10j

                              E2Ej-X2j

                                                                                                     E2Ej-X5j

                 Y (mm)                                                               Y (mm)

                                                               4
E2E2 2-WIRE AC                                                                                                                                  E2E2 2-WIRE AC

Unshielded Models E2E2-XjMYj

                             Sensing distance                                                                Sensing  distance
                                                                                                             X (mm)
                             X (mm)

                                        E2Ej-X5Mj

                                                                                                                      E2Ej-X18Mj

                                                                                                                           E2Ej-X10Mj

                             Y (mm)                                                                                Y (mm)

J                LEAKAGE CURRENT (TYPICAL)

(mA)

Leakage current  Proximity              Protective
                 Sensor
                 (when                  resistance

                 OFF)                               AC

                                                    power
                                                    supply

                             Supply voltage (V)

J                RESIDUAL OUTPUT VOLTAGE                                      (TYPICAL)

                                                                              Residual output voltage                           Residual output voltage

(V)                                                                 (V)                                               (V)

V                                                                   V                                                 V

vLoltage                     Residual output   voltage              voltage                                           voltage

                                                                                   Proximity                                         Proximity
                                                                                   Sensor                                            Sensor
load                                                                load                                              load
                             Proximity                                                                       100 VAC                                          200   VAC

Residual                     Sensor                                 Residual                                          Residual

                 Residual                                   24 VAC            Residual                                          Residual

                 load volt-                                                   load volt-                                        load volt-
                                                                                                                                age
                 age                                                          age

                             Load current      (mA)                                           Load  current  (mA)                               Load current  (mA)

                                                                                           5
E2E2 2-WIRE AC                                                                                                                                                                   E2E2 2-WIRE AC

J SENSING DISTANCE VS.                                          SENSING OBJECT (TYPICAL)

E2E2-X2Yj                                                       E2E2-X5Yj                                                                   E2E2-X10Yj

(mm)                                                Mild steel  (mm)                                                 Mild steel             (mm)                                                      Mild steel

Sensing distance                    Stainless steel (SUS304)    Sensing distance                   Stainless steel (SUS304)                 Sensing distance                         Stainless  steel (SUS304)

                                                                                                                                                                                                      Brass

                                                    Brass                                                            Brass                                                                            Aluminum

                                                    Aluminum                                                         Aluminum

                  Side length  of   sensing object d (mm)                         Side length  of  sensing object d (mm)                                      Side length        of  sensing    object d (mm)

E2E2-X5MYj                                                      E2E2-X10MYj                                                                 E2E2-X18MYj

(mm)                                                            (mm)                                                 Mild steel          (mm)

                                                    Mild steel                                                                                                                                        Mild steel

Sensing distance                    Stainless steel (SUS304)    distance                           Stainless  steel  (SUS304)            distance                                    Stainless  steel (SUS304)

                                                    Brass       Sensing                                              Brass               Sensing                                                      Brass

                                                    Aluminum                                                         Aluminum                                                                         Aluminum

                  Side length of sensing object d (mm)                            Side length of sensing object d (mm)                                        Side  length       of  sensing    object d (mm)

Dimensions

Unit: mm (inch)

J PRE-WIRED SENSORS

E2E2-X2jj                                                                                          E2E2-X5Mjj

                  21 dia.           60 (2.36)                                                         21 dia.                               60 (2.36)

                  (0.83)            55 (2.17)                                                         (0.83)         7                      55 (2.17)

                                                                                                                     (0.28)

                                                                                                                     9 dia.

                           M12 × 1                  Operation indicator                                                          M12  ×  1                                       Operation indicator

                                    Two clamping nut            Round vinyl-insulated cable                                                                   Two clamping  nut      Round vinyl-insulated cable

                                    Toothed washer              4 dia. (0.08 dia. x 60)                                                     Toothed washer                           4 dia. (0.08 dia. x 60)
                                                                                                                                                                                     2/3 cores
                                                                2/3 cores                                                                                                            Standard length: 2 m
                                                                Standard length: 2 m

                                                                                                   6
E2E2 2-WIRE AC                                                                                                                                                  E2E2 2-WIRE                AC

E2E2-X5jj                                                                                    E2E2-X10Mjj

   29 dia.                               65 (2.56)                                                      29 dia.                                 65 (2.56)

   (1.14)                                60 (2.36)                                                      (1.14)                   10             60 (2.36)

                                                                                                                                 (0.39)

                                                                                                                   14.8        dia.

                     M18 × 1                                 Operation indicator                                                     M18  ×  1                    Operation indicator

                                         Two clamping nut          Round vinyl-insulated     cable                                              Two clamping nut

                              Toothed    washer                    6 dia. (0.12 dia. x 45)                                                      Toothed washer    Round vinyl-insulated    cable
                                                                                                                                                                  6 dia. (0.12 dia. x 45)
                                                                   2/3 cores                                                                                      2/3 cores
                                                                   Standard length: 2 m
                                                                                                                                                                  Standard length: 2 m

E2E2-X10jj

       42 dia.                                    70 (2.76)

       (1.65)                            65 (2.56)

                                                                    Operation indicator                 Round vinyl-insulated cable
                                                                                                        6 dia. (0.12 dia. x 45)
                     M30  × 1.5                                                                         2/3 cores
                                         Two clamping nut
                                                                                                        Standard length: 2 m
                                 Toothed washer

E2E2-X18Mjj

            42 dia.                                     70 (2.76)

            (1.65)               13                     65 (2.56)

                              (0.51)

                              26.8 dia.

                                                                                  Operation  indicator           Round vinyl-insulated cable
                                                                                                                 6 dia. (0.12 dia. x 45)
                                         M30 × 1.5                                                               2/3 cores
                                                             Two clamping nut
                                                                                                                 Standard length: 2 m
                                                    Toothed washer

J  SENSORS                WITH CONNECTORS

E2E2-X2Yj-M4                                                                                 E2E2-X5MYj-M4

                                                                                                        21 dia.                                 70 (2.76)

   21 dia.                               70 (2.76)                                                      (0.83)                               55 (2.17)

   (0.83)                              55 (2.17)                                                        17                  7                4             10              1/2-20unf
                                                                                                                   (0.28)
   17                         4                     10              1/2-20unf

                                                                                                                   9 dia.                                       Operation  indicator

                                                             Operation indicator                                                 M12 x    1     Two clamping nut

                     M12  x1

                                         Two clamping nut                                                                                    Toothed washer

                              Toothed washer

                                                                                  7
E2E2 2-WIRE        AC                                                                                                                         E2E2          2-WIRE AC

E2E2-X5Yj-M4                                                               E2E2-X10MYj-M4

                                          75 (2.95)                                                                                           75 (2.95)

        29 dia.                                                                            29 dia.                                    60 (2.36)
                                                                                           (1.14)
        (1.14)                      60 (2.36)
                                                                                           24                           10               4
        24                                                                                                              (0.39)                   10                1/2-20unf
                                 4             10
                                                                       1/2-20unf

                                                            Operation  indicator                             14.8 dia.                                      Operation indicator

                   M18  x  1                                                                                            M18        x  1

                                       Two clamping nut                                                                                          Two clamping nut

                                                                                                                                         Toothed washer

                           Toothed washer

E2E2-X10Yj-M4                                                                     E2E2-X18MYj-M4

        42 dia.                                80 (3.15)                                           42 dia.                                          80 (3.15)

        (1.65)                            65 (2.56)                                                (1.65)                                        65 (2.56)

            36                         5                    10                                      36                                   13      5             10

                                                                                                                                      (0.51)

                                                                                                                        26.8 dia.

                                                                       1/2-20unf                                                                                   1/2-20unf

                        M30 x 1.5                        Operation     indicator                                                                            Operation indicator

                                               Two clamping nut                                                                       M30 x 1.5             Two clamping nut

                                       Toothed washer                                                                                         Toothed washer

J  MOUNTING        HOLES

   F

Dimensions                          M12                                              M18                                              M30

F (mm)                              12.5 mm    (0.49   in)  dia.                     18.5  mm  (0.73    in)  dia.                     30.5 mm (1.20 in) dia.

Installation

J PIN ARRANGEMENT

E2E2-XjYj-M4

Applicable models  Pin arrangement

E2E2-XjYj-M4                                   Load

                              3     2                                  AC

                                                                                  8
E2E2 2-WIRE AC                                                                         E2E2       2-WIRE  AC

J  MOUNTING

Do not tighten the nut with excessive force. A washer must be
used with the nut.

                                                                                          d dia.

       Shielded Model                  Unshielded Model

                    Part B  Part A             Part B    Part A

Note:  The table below shows the tightening torques for part A and
       part B nuts. In the previous examples, the nut is on the sen-
       sor head side (part B) and hence the tightening torque for
       part B applies. If this nut is in part A, the tightening torque for
       part A applies instead.

Type                                   Torque

M12                                    30 N S m (310 kgf S cm)

M18                                    70 N S m (710 kgf S cm)

M30                                    180 N S m (1,800 kgf S cm)

J  EFFECTS OF SURROUNDING METAL

When mounting the E2E2 within a metal panel, ensure that the
clearances given in the table below are maintained. Failure to
maintain these distances may cause deterioration in the perfor-
mance of the sensor.

Type                                Dimension                   M12         M18           M30

Shielded                            ℓ                           0 mm        0 mm          0 mm

                                    d                           12 mm       18 mm         30 mm

                                    D                           0 mm        0 mm          0 mm

                                    m                           8 mm        20 mm         40 mm

                                    n                           18 mm       27 mm         45 mm

Unshielded                          ℓ                           15 mm       22 mm         30 mm

                                    d                           40 mm       55 mm         90 mm

                                    D                           15 mm       22 mm         30 mm

                                    m                           20 mm       40 mm         70 mm

                                    n                           36 mm       54 mm         90 mm

J  MUTUAL INTERFERENCE                                                              A  B

When installing two or more Sensors face to face or side by side,
ensure that the minimum distances given in the following table
are maintained.

Type                                Dimension                   M12         M18           M30

Shielded                            A                           30 mm       50 mm         100 mm

                                    B                           20 mm       35 mm         70 mm

Unshielded                          A                           120 mm      200 mm        300 mm

                                    B                           100 mm      110 mm        200 mm

                                                                      9
E2E2 2-WIRE AC                                                                                                      E2E2 2-WIRE AC

Precautions

J INSTALLATION                                                            or welding machine) near the Proximity Sensor, connect a surge
                                                                          absorber to the machine.

Power Reset Time                                                          Leakage Current

The Proximity Sensor is ready to operate within 100 ms after              When the Proximity Sensor is OFF, the Proximity Sensor has
                                                                          leakage current. Refer to Leakage Current Characteristics. In this
power is supplied. If power supplies are connected to the Proxim-         case, the load is imposed with a small voltage and the load may
ity Sensor and load respectively, be sure to supply power to the
Proximity Sensor before supplying power to the load.                      not be reset. Before using the Proximity Sensor, make sure that
                                                                          this voltage is less than the load reset voltage. The AC 2-wire
Power OFF                                                                 Proximity Sensor cannot be connected to any card-lift-off relay

The Proximity Sensor may output a pulse signal when it is turned          (e.g., the G2A) because contact vibration of the relay will be
off. Turn off the load before turning off the Proximity Sensor.
                                                                          caused by the leakage current and the life of the relay will be
                                                                          shortened.
Power Supply Transformer

When using a DC power supply, make sure that the DC power                 Countermeasures Against Leakage Current
supply has an insulated transformer. Do not use a DC power
supply with an auto-transformer.                                          AC 2-wire Models

Target Object                                                             Connect a bleeder resistor as the bypass for the leakage current
                                                                          so that the current flowing into the load will be less than the load
                                                                          reset current.
Metal Coating

The sensing distances of the Proximity Sensor vary with the met-          As shown in the following diagram, connect the bleeder resistor
                                                                          so that the current flowing into the Proximity Sensor will be 10
al coating on target objects.                                             mA minimum and the residual voltage imposed on the load will

J WIRING                                                                  be less than the load reset voltage.

High-tension Lines                                                                               Load

Wiring through Metal Conduit                                                                                        VAC power
                                                                                          Bleeder resistor R        supply VS
If there is a power or high-tension line near the cable of the Prox-
imity Sensor, wire the cable through an independent metal con-
duit to prevent against Proximity Sensor damage or malfunction-
ing.                                                                      Refer to the following to calculate the bleeder resistance and the
                                                                          allowable power of the bleeder resistor.

Cable Tractive Force                                                      R ≦ VS/(10 -- I) (kΩ)

Do not pull cables with the tractive forces exceeding the follow-         P > VS2/R (mW)
ing.
                                                                          P:  The allowable power of the bleeder resistor. (The actual pow-
                                                                              er capacity of the bleeder resistor must be at least a few
Diameter                          Tractive force                              times as large as the allowable power of the bleeder resistor.)

4 mm dia. max.                    30 N max.                               I:  Load current (mA)

4 mm dia. min.                    50 N max.                               The following resistors are recommended.

                                                                          100 VAC (supply voltage): A resistor with a resistance of 10 kΩ
                                                                          maximum and an allowable power of 3 W minimum
J MOUNTING                                                                200 VAC (supply voltage): A resistor with a resistance of 20 kΩ

The Proximity Sensor must not be subjected to excessive shock             maximum and an allowable power of 10 W minimum
                                                                          If these resistors generate excessive heat, use a resistor with a
with a hammer when it is installed, or the Proximity Sensor may           resistance of 10 kΩ maximum and an allowable power of 5 W
be damaged or lose its water-resistance.
                                                                          minimum at 100 VAC and a resistor with a resistance of 20 kΩ
J ENVIRONMENT                                                             maximum and an allowable power of 10 W minimum at 200 VAC
                                                                          instead.
Water Resistance

Do not use the Proximity Sensor underwater, outdoors, or in the
rain.

Operating Environment

Be sure to use the Proximity Sensor within its operating ambient
temperature range and do not use the Proximity Sensor outdoors
so that its reliability and life expectancy can be maintained. Al-
though the Proximity Sensor is water resistant, a cover to protect
the Proximity Sensor from water or water-soluble machining oil is
recommended so that its reliability and life expectancy can be
maintained.
Do not use the Proximity Sensor in an environment with chemical
gas (e.g., strong alkaline or acid gasses including nitric, chromic,
and concentrated sulfuric acid gases).

J CONNECTING LOAD

Refer to the following before using AC 2-wire Proximity Sensors.

Surge Protection

Although the Proximity Sensor has a surge absorption circuit, if
there is any machine that has a large surge current (e.g., a motor

                                                                      10
E2E2 2-WIRE AC                                                                         E2E2 2-WIRE AC

NOTE: DIMENSIONS SHOWN          ARE  IN MILLIMETERS. To convert millimeters            to inches divide by 25.4.

                         R           OMRON ON--LINE

OMRON ELECTRONICS LLC                                                                  OMRON CANADA, INC.
One East Commerce Drive                                                                885 Milner Avenue
Schaumburg, IL 60173                 Global -- http://www.omron.com                    Scarborough, Ontario M1B 5V8

1-800-55-OMRON                       USA -- http://www.omron.com/oei                   416-286-6465

                                     Canada -- http://www.omron.com/oci

Cat. No. CEDSAX4         11/01       Specifications subject to change without notice.                     Printed in U.S.A.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

   E2E2-X10C2  E2E2-X2Y1-M4   E2E2-X10MY1-US  E2E2-X10Y1-US    E2E2-X18MC1     E2E2-X18MY1-US  E2E2-X2C1

   E2E2-X5Y1-M4  E2E2-X10B2-M1  E2E2-X10MC1   E2E2-X10MY1      E2E2-X10MY2-M4  E2E2-X10Y1-M4   E2E2-

X10Y1-US 5M    E2E2-X10Y2-M4  E2E2-X10Y2-US   E2E2-X18MB15 5M  E2E2-X18MB1 5M  E2E2-X18MB15-M1

E2E2-X18MC1 7M   E2E2-X18MY1 5M  E2E2-X18MY2-M4       E2E2-X18MY2-US  E2E2-X18MY2-US 5M    E2E2-X2B1-M1-

1  E2E2-X2B2   E2E2-X2C2   E2E2-X2Y1  E2E2-X2Y1 5M  E2E2-X2Y1-US  E2E2-X2Y1-US 5M    E2E2-X2Y2  E2E2-

X2Y2-US   E2E2-X2Y2-US 5M    E2E2-X5B2  E2E2-X5C1   E2E2-X5C2  E2E2-X5MB1 5M   E2E2-X5MC1  E2E2-X5MY1

E2E2-X5MY1 5M    E2E2-X5MY1-US  E2E2-X5MY1-US 5M      E2E2-X5MY2-M4   E2E2-X5MY2-US  E2E2-X5MY2-US 5M

E2E2-X5Y1  E2E2-X5Y1 5M    E2E2-X5Y1-US 5M    E2E2-X5Y2-US  E2E2-X5Y2-US 5M    E2E2-X10MB1-M1 OMS     E2E2-

X5Y1-US   E2E2-X10MY1-M4     E2E2-X10MY2  E2E2-X10Y1  E2E2-X10Y2  E2E2-X18MY1-M4     E2E2-X2Y2-M4  E2E2-

X5MY1-M4   E2E2-X5Y2    E2E2-X18MY2 2M    E2E2-X5MY2 2M  E2E2-X18MY1  E2E2-X10MY2-US  E2E2-X5Y2-M4

小广播

E2E2-X2Y1器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved