器件描述

Board Mount Temperature Sensors

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Maxim Integrated
产品种类:
Product Category:
Board Mount Temperature Sensors
输出类型:
Output Type:
Digital
Configuration:Local
Accuracy:+/- 2 C
最大工作温度:
Maximum Operating Temperature:
+ 100 C
最小工作温度:
Minimum Operating Temperature:
- 55 C
接口类型:
Interface Type:
1-Wire
Resolution:12 bit
电源电压-最大:
Supply Voltage - Max:
5.5 V
电源电压-最小:
Supply Voltage - Min:
3 V
Shutdown:No Shutdown
Temperature Threshold:Programmable
安装风格:
Mounting Style:
Through Hole
封装 / 箱体:
Package / Case:
TO-92-3
产品:
Product:
Sensor with Alarm
系列:
Series:
DS18B20-PAR
商标:
Brand:
Maxim Integrated
工作电源电流:
Operating Supply Current:
1.5 mA
零件号别名:
Part # Aliases:
DS18B20

DS18B20-PAR-TR器件文档内容

                                                                                                        DS18B20-PAR

                                                                                     1-Wire Parasite-Power

                                                                                     Digital Thermometer

   www.maxim-ic.com

FEATURES                                                                        PIN ASSIGNMENT

•    Unique 1-Wire® interface requires only one

     port pin for communication                                                                DALLAS

•    Derives    power    from   data   line                (“parasite                          18B20P

     power”)—does not need a local power supply

•    Multi-drop   capability   simplifies    distributed                                       1    2   3

     temperature sensing applications

•    Requires no external components

•    ±0.5°C accuracy from –10°C to +85°C

•    Measures     temperatures     from      –55°C         to

     +100°C (–67°F to +212°F)

•    Thermometer      resolution  is   user-selectable

     from 9 to 12 bits

•    Converts temperature to 12-bit digital word in                                            GND  DQ  NC

     750 ms (max.)

•    User–definable      non-volatile      temperature

     alarm settings

•    Alarm    search     command       identifies          and                                 1    2   3

     addresses    devices   whose      temperature         is

     outside  of  programmed      limits   (temperature                                     (BOTTOM VIEW)

     alarm condition)                                                                          TO-92

•    Software compatible with the DS1822-PAR                                         (DS18B20-PAR)

•    Ideal for use in remote sensing applications

     (e.g., temperature probes) that do not have a

     local power source                                                         PIN DESCRIPTION

                                                                                GND  - Ground

                                                                                DQ   - Data In/Out

                                                                                NC   - No Connect

DESCRIPTION

The DS18B20-PAR digital thermometer provides 9 to 12–bit centigrade temperature measurements and

has  an  alarm    function  with  nonvolatile              user-programmable         upper     and  lower   trigger  points.  The

DS18B20-PAR does not need an external power supply because it derives power directly from the data

line (“parasite power”).       The DS18B20-PAR communicates over a 1-Wire bus, which by definition

requires only one data line (and ground) for communication with a central microprocessor.                            It has an

operating temperature range of –55°C to +100°C and is accurate to ±0.5°C over a range of –10°C to

+85°C.

Each DS18B20-PAR has a unique 64-bit identification code, which allows multiple DS18B20-PARs to

function on the same 1–wire bus; thus, it is simple to use one microprocessor to control many DS18B20-

PARs distributed over a large area.          Applications that can benefit from this feature include HVAC

environmental controls, temperature monitoring systems inside buildings, equipment or machinery, and

process monitoring and control systems.

1-Wire is a registered trademark of Dallas Semiconductor.              1 of 19                                       101207
                                                                                         DS18B20-PAR

DETAILED PIN DESCRIPTIONS                      Table 1

PIN          SYMBOL                                             DESCRIPTION

1            GND           Ground.

2            DQ            Data Input/Output pin. Open-drain 1-Wire interface pin. Also provides power

                           to the device when used in parasite power mode (see “Parasite Power” section.)

3            NC            No Connect. Doesn’t connect to internal circuit.

OVERVIEW

The DS18B20-PAR uses Dallas’ exclusive 1-Wire bus protocol that implements bus communication

using one control signal.  The control line requires a weak pullup resistor since all devices are linked to

the bus via a 3-state or open-drain port (the DQ pin in the case of the DS18B20-PAR).              In this bus

system, the microprocessor (the master device) identifies and addresses devices on the bus using each

device’s unique 64-bit code.  Because each device has a unique code, the number of devices that can be

addressed on one bus is virtually unlimited.   The 1-Wire bus protocol, including detailed explanations of

the commands and “time slots,” is covered in the 1-WIRE BUS SYSTEM section of this datasheet.

An important feature of the DS18B20-PAR is its ability to operate without an external power supply.

Power is instead supplied through the 1-Wire pullup resistor via the DQ pin when the bus is high.             The

high bus signal also charges an internal capacitor (CPP), which then supplies power to the device when the

bus is low. This method of deriving power from the 1-Wire bus is referred to as “parasite power.”

Figure 1 shows a block diagram of the DS18B20-PAR, and pin descriptions are given in Table 1.                 The

64-bit  ROM  stores  the   device’s    unique  serial  code.    The  scratchpad  memory  contains  the      2-byte

temperature register that stores the digital output from the temperature sensor. In addition, the scratchpad

provides access to the 1-byte upper and lower alarm trigger registers (TH and TL).       The TH and TL

registers are nonvolatile (EEPROM), so they will retain their data when the device is powered down.

DS18B20-PAR          BLOCK DIAGRAM             Figure 1

        VPU

4.7K                       PARASITE POWER                            MEMORY CONTROL  DS18B20-PAR

                              CIRCUIT                                LOGIC

        DQ

                                                                                     TEMPERATURE SENSOR

                              INTERNAL VDD     64-BIT ROM

                                                       AND                           ALARM HIGH TRIGGER (TH)

                                               1-wire PORT           SCRATCHPAD          REGISTER (EEPROM)

                              CPP                                                    ALARM LOW TRIGGER (TL)

                                                                                         REGISTER (EEPROM)

        GND                                                                          CONFIGURATION REGISTER

                                                                                         (EEPROM)

                                                                                         8-BIT CRC GENERATOR

                                                       2 of 19
                                                                                                             DS18B20-PAR

PARASITE POWER

The DS18B20-PAR’s parasite power circuit allows the DS18B20-PAR to operate without a local external

power supply. This ability is especially useful for applications that require remote temperature sensing or

that are very space constrained.       Figure 1 shows the DS18B20-PAR’s parasite-power control circuitry,

which “steals” power from the 1-Wire bus via the DQ pin when the bus is high.                       The stolen charge

powers the DS18B20-PAR while the bus is high, and some of the charge is stored on the parasite power

capacitor (CPP) to provide power when the bus is low.

The 1-Wire bus and CPP can provide sufficient parasite power to the DS18B20-PAR for most operations

as  long  as  the  specified   timing  and  voltage   requirements       are  met  (refer  to  the  DC   ELECTRICAL

CHARACTERISTICS and the AC ELECTRICAL CHARACTERISTICS sections of this data sheet).

However, when the DS18B20-PAR is performing temperature conversions or copying data from the

scratchpad memory to EEPROM, the operating current can be as high as 1.5 mA.                       This current can cause

an unacceptable voltage drop across the weak 1-Wire pullup resistor and is more current than can be

supplied by CPP.     To assure that the DS18B20-PAR has sufficient supply current, it is necessary to

provide a strong pullup on the 1-Wire bus whenever temperature conversions are taking place or data is

being copied from the scratchpad to EEPROM.                This can be accomplished by using a MOSFET to pull

the bus directly to the rail as shown in Figure 2.         The 1-Wire bus must be switched to the strong pullup

within 10 μs (max) after a Convert T [44h] or Copy Scratchpad [48h] command is issued, and the bus

must be held high by the pullup for the duration of the conversion (tconv) or data transfer (twr = 10 ms).

No other activity can take place on the 1-Wire bus while the pullup is enabled.

SUPPLYING THE DS18B20-PAR DURING TEMPERATURE CONVERSIONS

Figure 2

                                                      VPU

                                                                         DS18B20-PAR

                                VPU                                      GND       DQ

             Micro-

          processor                  4.7K

                                                           1-Wire Bus                              To Other

                                                                                                   1-Wire Devices

OPERATION – MEASURING TEMPERATURE

The core functionality of the DS18B20-PAR is its direct-to-digital temperature sensor. The resolution of

the temperature sensor is user-configurable to 9, 10, 11, or 12 bits, which corresponds to increments of

0.5°C, 0.25°C, 0.125°C, and 0.0625°C, respectively. The default resolution at power-up is 12-bit.

The DS18B20-PAR powers-up in a low-power idle state; to initiate a temperature measurement and A-to-

D conversion, the master must issue a Convert T [44h] command.                        Following the conversion, the

resulting thermal data is stored in the 2-byte temperature register in the scratchpad memory and the

DS18B20-PAR        returns  to  its  idle  state.     The  DS18B20-PAR        output   data    is  calibrated  in  degrees

centigrade;   for  Fahrenheit   applications,      a  lookup  table  or  conversion    routine     must  be    used.  The

temperature data is stored as a 16-bit sign-extended two’s complement number in the temperature register

(see Figure 3). The sign bits (S) indicate if the temperature is positive or negative: for positive numbers S

= 0 and for negative numbers S = 1.         If the DS18B20-PAR is configured for 12-bit resolution, all bits in

the temperature register will contain valid data.          For 11-bit resolution, bit 0 is undefined.          For 10-bit

                                                           3 of 19
                                                                                                                        DS18B20-PAR

resolution, bits 1 and 0 are undefined, and for 9-bit resolution bits 2, 1 and 0 are undefined. Table 2 gives

examples  of     digital  output      data   and  the     corresponding          temperature    reading     for  12-bit     resolution

conversions.

TEMPERATURE REGISTER FORMAT                                      Figure 3

                 bit 7           bit 6            bit 5          bit 4           bit 3          bit 2            bit 1         bit 0

LS Byte          23               22              21             20              2-1            2-2              2-3           2-4

                 bit 15          bit 14           bit 13         bit 12          bit 11         bit 10           bit 9         bit 8

MS Byte               S               S           S              S               S              26               25            24

TEMPERATURE/DATA RELATIONSHIP                                        Table 2

                      TEMPERATURE                 DIGITAL OUTPUT                 DIGITAL OUTPUT

                                                              (Binary)                          (Hex)

                          +85°C*                  0000 0101 0101 0000                           0550h

                          +25.0625°C              0000 0001 1001 0001                           0191h

                          +10.125°C               0000 0000 1010 0010                           00A2h

                          +0.5°C                  0000 0000 0000 1000                           0008h

                                 0°C              0000 0000 0000 0000                           0000h

                              -0.5°C              1111 1111 1111 1000                           FFF8h

                          -10.125°C               1111 1111 0101 1110                           FF5Eh

                          -25.0625°C              1111 1110 0110 1111                           FE6Fh

                              -55°C               1111 1100 1001 0000                           FC90h

                 *The power-on reset value of the temperature register is +85°C

OPERATION – ALARM SIGNALING

After the DS18B20-PAR performs a temperature conversion, the temperature value is compared to the

user-defined two’s complement alarm trigger values stored in the 1-byte TH and TL registers (see Figure

4). The sign bit (S) indicates if the value is positive or negative: for positive numbers S = 0 and for

negative numbers S = 1.          The TH and TL registers are nonvolatile (EEPROM) so they will retain data

when the device is powered down.             TH and TL can be accessed through bytes 2 and 3 of the scratchpad as

explained in the MEMORY section of this datasheet.

TH AND TL REGISTER FORMAT                                 Figure 4

          bit 7           bit 6          bit 5            bit 4           bit 3          bit 2          bit 1           bit 0

          S               26             25               24              23             22             21              20

Only bits 11 through 4 of the temperature register are used in the TH and TL comparison since TH and TL

are 8-bit registers.     If the result of a temperature measurement is higher than or equal to TH or lower than

or equal to TL, an alarm condition exists and an alarm flag is set inside the DS18B20-PAR.                               This flag is

updated after every temperature measurement; therefore, if the alarm condition goes away, the flag will

be turned off after the next temperature conversion.

                                                                 4 of 19
                                                                                                DS18B20-PAR

The master device can check the alarm flag status of all DS DS18B20-PARs on the bus by issuing an

Alarm Search [ECh] command.      Any DS18B20-PARs with a set alarm flag will respond to the command,

so the master can determine exactly which DS18B20-PARs have experienced an alarm condition.                   If an

alarm condition exists and the TH or TL settings have changed, another temperature conversion should be

done to validate the alarm condition.

64-BIT LASERED ROM CODE

Each DS18B20-PAR contains a unique 64–bit code (see Figure 5) stored in ROM. The least significant 8

bits of the ROM code contain the DS18B20-PAR’s 1–wire family code: 28h. The next 48 bits contain a

unique serial number. The most significant 8 bits contain a cyclic redundancy check (CRC) byte that is

calculated from the first 56 bits of the ROM code.       A detailed explanation of the CRC bits is provided in

the CRC GENERATION section.                The 64–bit ROM code and associated ROM function control logic

allow the DS18B20-PAR to operate as a 1–wire device using the protocol detailed in the 1-WIRE BUS

SYSTEM section of this datasheet.

64-BIT LASERED ROM CODE                      Figure 5

          8-BIT CRC                        48-BIT SERIAL NUMBER              8-BIT FAMILY CODE (28h)

MSB                              LSB   MSB                              LSB  MSB                              LSB

MEMORY

The DS18B20-PAR’s memory is organized as shown in Figure 6.                  The memory consists of an SRAM

scratchpad with nonvolatile EEPROM storage for the high and low alarm trigger registers (TH and TL)

and configuration register.      Note that if the DS18B20-PAR alarm function is not used, the TH and TL

registers can serve as general-purpose memory. All memory commands are described in detail in the

DS18B20-PAR FUNCTION COMMANDS section.

Byte   0  and  byte  1  of  the  scratchpad  contain  the    LSB  and   the  MSB     of  the  temperature  register,

respectively.  These bytes are read-only.         Bytes 2 and 3 provide access to TH and TL registers.     Byte 4

contains  the  configuration     register  data,  which  is  explained  in   detail  in  the  CONFIGURATION

REGISTER section of this datasheet.          Bytes 5, 6 and 7 are reserved for internal use by the device and

cannot be overwritten.

Byte 8 of the scratchpad is read-only and contains the cyclic redundancy check (CRC) code for bytes 0

through 7 of the scratchpad.     The DS18B20-PAR generates this CRC using the method described in the

CRC GENERATION section.

Data is written to bytes 2, 3, and 4 of the scratchpad using the Write Scratchpad [4Eh] command, and the

data must be transmitted to the DS18B20-PAR starting with the least significant bit of byte 2.             To verify

data integrity, the scratchpad can be read (using the Read Scratchpad [BEh] command) after the data is

written.  When reading the scratchpad, data is transferred over the 1-Wire bus starting with the least

significant bit of byte 0.   To transfer the TH, TL and configuration data from the scratchpad to EEPROM,

the master must issue the Copy Scratchpad [48h] command.

Data in the EEPROM registers is retained when the device is powered down; at power-up the EEPROM

data is reloaded into the corresponding scratchpad locations.     Data can also be reloaded from EEPROM

to the scratchpad at any time using the Recall E2 [B8h] command.        The master can issue “read time slots”

(see the 1-WIRE BUS SYSTEM section) following the Recall E2 command and the DS18B20-PAR will

indicate the status of the recall by transmitting 0 while the recall is in progress and 1 when the recall is

done.

                                                      5 of 19
                                                                                                      DS18B20-PAR

DS18B20-PAR MEMORY MAP                    Figure 6

                   SCRATCHPAD (Power-up State)

           byte 0   Temperature LSB   (50h)      (85°C)

           byte 1   Temperature MSB (05h)                                           EEPROM

           byte 2   TH Register or User Byte 1*                              TH Register or User Byte 1

           byte 3   TL Register or User Byte 2*                              TL Register or User Byte 2

           byte 4   Configuration Register*                                  Configuration Register

           byte 5   Reserved (FFh)

           byte 6   Reserved

           byte 7   Reserved (10h)

           byte 8   CRC*

                   *Power-up state depends on value(s) stored

                    in EEPROM

CONFIGURATION REGISTER

Byte 4 of the scratchpad memory contains the configuration register, which is organized as illustrated in

Figure 7.  The user can set the conversion resolution of the DS18B20-PAR using the R0 and R1 bits in

this register as shown in Table 3.    The power-up default of these bits is R0 = 1 and R1 = 1 (12-bit

resolution). Note that there is a direct tradeoff between resolution and conversion time. Bit 7 and bits 0-4

in the configuration register are reserved for internal use by the device and cannot be overwritten.

CONFIGURATION REGISTER                Figure 7

                    bit 7      bit 6  bit 5      bit 4         bit 3  bit 2  bit 1  bit 0

                       0       R1     R0         1             1      1      1        1

THERMOMETER RESOLUTION CONFIGURATION                                         Table 3

                    R1        R0      Resolution               Max Conversion Time

                    0          0      9-bit                    93.75 ms         (tCONV/8)

                    0          1      10-bit                   187.5 ms         (tCONV/4)

                    1          0      11-bit                      375 ms        (tCONV/2)

                    1          1      12-bit                      750 ms            (tCONV)

CRC GENERATION

CRC bytes are provided as part of the DS18B20-PAR’s 64-bit ROM code and in the 9th byte of the

scratchpad memory.  The ROM code CRC is calculated from the first 56 bits of the ROM code and is

contained in the most significant byte of the ROM.             The scratchpad CRC is calculated from the data

stored in the scratchpad, and therefore it changes when the data in the scratchpad changes.              The CRCs

provide the bus master with a method of data validation when data is read from the DS18B20-PAR.               To

verify that data has been read correctly, the bus master must re-calculate the CRC from the received data

                                                    6 of 19
                                                                                                       DS18B20-PAR

and then compare this value to either the ROM code CRC (for ROM reads) or to the scratchpad CRC (for

scratchpad reads). If the calculated CRC matches the read CRC, the data has been received error free. The

comparison of CRC values and the decision to continue with an operation are determined entirely by the

bus master.  There is no circuitry inside the DS18B20-PAR that prevents a command sequence from

proceeding if the DS18B20-PAR CRC (ROM or scratchpad) does not match the value generated by the

bus master.

The equivalent polynomial function of the CRC (ROM or scratchpad) is:          CRC = X8 + X5 + X4 + 1

The bus master can re-calculate the CRC and compare it to the CRC values from the DS18B20-PAR

using the polynomial generator shown in Figure 8. This circuit consists of a shift register and XOR gates,

and the shift register bits are initialized to 0. Starting with the least significant bit of the ROM code or the

least significant bit of byte 0 in the scratchpad, one bit at a time should shifted into the shift register.

After shifting in the 56th bit from the ROM or the most significant bit of byte 7 from the scratchpad, the

polynomial generator will contain the re-calculated CRC.          Next, the 8-bit ROM code or scratchpad CRC

from the DS18B20-PAR must be shifted into the circuit.               At this point, if the re-calculated CRC was

correct, the shift register will contain all 0s. Additional information about the Dallas 1-Wire cyclic

redundancy   check  is  available  in   Application  Note     27     entitled  “Understanding     and  Using  Cyclic

Redundancy Checks with Dallas Semiconductor Touch Memory Products.”

CRC GENERATOR                  Figure 8                                                                INPUT

                                              XOR                XOR                                   XOR

     (MSB)                                                                                 (LSB)

1-WIRE BUS SYSTEM

The 1-Wire bus system uses a single bus master to control one or more slave devices.                   The DS18B20-

PAR is always a slave. When there is only one slave on the bus, the system is referred to as a “single-

drop” system; the system is “multi-drop” if there are multiple slaves on the bus.

All data and commands are transmitted least significant bit first over the 1-Wire bus.

The  following     discussion  of  the  1-Wire  bus  system      is  broken    down  into  three  topics:  hardware

configuration, transaction sequence, and 1-Wire signaling (signal types and timing).

HARDWARE CONFIGURATION

The 1-Wire bus has by definition only a single data line.        Each device (master or slave) interfaces to the

data line via an open drain or 3–state port.       This allows each device to “release” the data line when the

device is not transmitting data so the bus is available for use by another device.         The 1-Wire port of the

DS18B20-PAR (the DQ pin) is open drain with an internal circuit equivalent to that shown in Figure 9.

The 1-Wire bus requires an external pullup resistor of approximately 5 kΩ; thus, the idle state for the 1-

Wire bus is high.   If for any reason a transaction needs to be suspended, the bus MUST be left in the idle

state if the transaction is to resume.   Infinite recovery time can occur between bits so long as the 1-Wire

bus is in the inactive (high) state during the recovery period.       If the bus is held low for more than 480 μs,

all components on the bus will be reset.        In addition, to assure that the DS18B20-PAR has sufficient

supply current during temperature conversions, it is necessary to provide a strong pullup (such as a

MOSFET) on the 1-Wire bus whenever temperature conversions or EEPROM writes are taking place (as

described in the PARASITE POWER section).

                                                     7 of 19
                                                                                                 DS18B20-PAR

HARDWARE CONFIGURATION                   Figure 9

                                 VPU

             Micro-                            VPU

         processor               Strong                              DS18B20-PAR  1-WIRE PORT

                                 Pullup

                                         4.7K                   DQ

                                                                Pin                          RX

         RX                                         1-wire bus

                                                                     5 μA

                                                                     Typ.                    TX

         TX                                                                               100 Ω

                                                                                          MOSFET

                                         RX = RECEIVE

                                         TX = TRANSMIT

TRANSACTION SEQUENCE

The transaction sequence for accessing the DS18B20-PAR is as follows:

Step 1.  Initialization

Step 2.  ROM Command (followed by any required data exchange)

Step 3.  DS18B20-PAR Function Command           (followed by any required data exchange)

It is very important to follow this sequence every time the DS18B20-PAR is accessed, as the DS18B20-

PAR will not respond if any steps in the sequence are missing or out of order. Exceptions to this rule are

the  Search  ROM     [F0h]  and  Alarm  Search  [ECh]  commands.     After  issuing  either  of  these  ROM

commands, the master must return to Step 1 in the sequence.

INITIALIZATION

All transactions on the 1-Wire bus begin with an initialization sequence. The initialization sequence

consists of a reset pulse transmitted by the bus master followed by presence pulse(s) transmitted by the

slave(s). The presence pulse lets the bus master know that slave devices (such as the DS18B20-PAR) are

on the bus and are ready to operate.     Timing for the reset and presence pulses is detailed in the

1-WIRE SIGNALING section.

ROM COMMANDS

After the bus master has detected a presence pulse, it can issue a ROM command. These commands

operate on the unique 64–bit ROM codes of each slave device and allow the master to single out a

specific device if many are present on the 1-Wire bus.          These commands also allow the master to

determine how many and what types of devices are present on the bus or if any device has experienced an

alarm condition.  There are five ROM commands, and each command is 8 bits long.           The master device

must issue an appropriate ROM command before issuing a DS18B20-PAR function command.                        A

flowchart for operation of the ROM commands is shown in Figure 10.

SEARCH ROM [F0h]

When a system is initially powered up, the master must identify the ROM codes of all slave devices on

the bus, which allows the master to determine the number of slaves and their device types.        The master

learns the ROM codes through a process of elimination that requires the master to perform a Search ROM

                                                    8 of 19
                                                                                            DS18B20-PAR

cycle (i.e., Search ROM command followed by data exchange) as many times as necessary to identify all

of the slave devices.  If there is only one slave on the bus, the simpler Read ROM command (see below)

can be used in place of the Search ROM process.                      For a detailed explanation of the Search ROM

procedure, refer to the iButton® Book of Standards at www.ibutton.com/ibuttons/standard.pdf.                  After

every Search ROM cycle, the bus master must return to Step 1 (Initialization) in the transaction sequence.

READ ROM [33h]

This command can only be used when there is one slave on the bus.    It allows the bus master to read the

slave’s 64-bit ROM code without using the Search ROM procedure.      If this command is used when there

is more than one slave present on the bus, a data collision will occur when all the slaves attempt to

respond at the same time.

MATCH ROM [55h]

The match ROM command followed by a 64–bit ROM code sequence allows the bus master to address a

specific slave device on a multi-drop or single-drop bus.            Only the slave that exactly matches the 64–bit

ROM code sequence will respond to the function command issued by the master; all other slaves on the

bus will wait for a reset pulse.

SKIP ROM [CCh]

The master can use this command to address all devices on the bus simultaneously without sending out

any ROM code information. For example, the master can make all DS18B20-PARs on the bus perform

simultaneous temperature conversions by issuing a Skip ROM command followed by a Convert T [44h]

command.  Note, however, that the Skip ROM command can only be followed by the Read Scratchpad

[BEh] command when there is one slave on the bus. This sequence saves time by allowing the master to

read from the device without sending its 64–bit ROM code.            This sequence will cause a data collision on

the bus if there is more than one slave since multiple devices will attempt to transmit data simultaneously.

ALARM SEARCH [ECh]

The operation of this command is identical to the operation of the Search ROM command except that

only slaves with a set alarm flag will respond.             This command allows the master device to determine if

any DS18B20-PARs experienced an alarm condition during the most recent temperature conversion.

After every Alarm Search cycle (i.e., Alarm Search command followed by data exchange), the bus master

must return to Step 1 (Initialization) in the transaction sequence.  Refer to the OPERATION – ALARM

SIGNALING section for an explanation of alarm flag operation.

DS18B20-PAR FUNCTION COMMANDS

After the bus master has used a ROM command to address the DS18B20-PAR with which it wishes to

communicate, the master can issue one of the DS18B20-PAR function commands.                 These commands

allow the master to write to and read from the DS18B20-PAR’s scratchpad memory, initiate temperature

conversions and determine the power supply mode.            The DS18B20-PAR function commands, which are

described below, are summarized in Table 4 and illustrated by the flowchart in Figure 11.

CONVERT T [44h]

This command initiates a single temperature conversion.              Following the conversion, the resulting thermal

data is stored in the 2-byte temperature register in the scratchpad memory and the DS18B20-PAR returns

to its low-power idle state.      Within 10 μs (max) after this command is issued the master must enable a

strong pullup on the 1-Wire bus for the duration of the conversion (tconv) as described in the PARASITE

POWER section.

WRITE SCRATCHPAD [4Eh]

This command allows the master to write 3 bytes of data to the DS18B20-PAR’s scratchpad.      The first

data byte is written into the TH register (byte 2 of the scratchpad), the second byte is written into the TL

register (byte 3), and the third byte is written into the configuration register (byte 4).  Data must be

iButton is a registered trademark of Dallas Semiconductor.  9 of 19
                                                                                                   DS18B20-PAR

transmitted least significant bit first. All three bytes MUST be written before the master issues a reset, or

the data may be corrupted.

READ SCRATCHPAD [BEh]

This command allows the master to read the contents of the scratchpad.         The data transfer starts with the

least significant bit of byte 0 and continues through the scratchpad until the 9th byte (byte 8 – CRC) is

read.  If only part of the scratchpad contents is required, the master may issue a reset to terminate reading

at any time.

COPY SCRATCHPAD [48h]

This command copies the contents of the scratchpad TH, TL and configuration registers (bytes 2, 3 and 4)

to EEPROM.    Within 10 μs (max) after this command is issued the master must enable a strong pullup on

the 1-Wire bus for at least 10 ms as described in the PARASITE POWER section.

RECALL E2 [B8h]

This command recalls the alarm trigger values (TH and TL) and configuration data from EEPROM and

places the data in bytes 2, 3, and 4, respectively, in the scratchpad memory.  The master device can issue

“read time slots” (see the 1-WIRE BUS SYSTEM section) following the Recall E2 command and the

DS18B20-PAR will indicate the status of the recall by transmitting 0 while the recall is in progress and

1 when the recall is done.  The recall operation happens automatically at power-up, so valid data is

available in the scratchpad as soon as power is applied to the device.

DS18B20-PAR Function Command Set                    Table 4

                                                                         1-Wire Bus Activity

       Command              Description                        Protocol  After Command is Issued     Notes

                            TEMPERATURE CONVERSION COMMANDS

Convert T         Initiates temperature                        44h                     None                    1

                  conversion.

                               MEMORY COMMANDS

Read Scratchpad   Reads the entire scratchpad                  BEh       DS18B20-PAR transmits up              2

                  including the CRC byte.                                to 9 data bytes to master.

Write Scratchpad  Writes data into scratchpad                  4Eh       Master transmits 3 data               3

                  bytes 2, 3, and 4 (TH, TL, and                         bytes to DS18B20-PAR.

                  configuration registers).

Copy Scratchpad   Copies TH, TL, and                           48h                     None                    1

                  configuration register data from

                  the scratchpad to EEPROM.

Recall E2         Recalls TH, TL, and                          B8h       DS18B20-PAR transmits

                  configuration register data from                       recall status to master.

                  EEPROM to the scratchpad.

NOTES:

1.  The master must enable a strong pullup on the 1-Wire bus during temperature conversions and copies

    from the scratchpad to EEPROM. No other bus activity may take place during this time.

2.  The master can interrupt the transmission of data at any time by issuing a reset.

3.  All three bytes must be written before a reset is issued.

                                                  10 of 19
                                                                                                                          DS18B20-PAR

ROM  COMMANDS FLOW CHART                                    Figure 10

                     Initialization          MASTER TX

                     Sequence                RESET PULSE

                                             DS18B20-PAR

                                             TX PRESENCE

                                             PULSE

                                             MASTER TX ROM

                                             COMMAND

     33h             N               55h        N                     F0h          N  ECh                 N     CCh       N

     READ ROM           MATCH ROM                                 SEARCH ROM          ALARM SEARCH              SKIP ROM

     COMMAND            COMMAND                                   COMMAND             COMMAND                   COMMAND

     Y                               Y                                     Y               Y                    Y

                        MASTER TX

                               BIT 0

                                                            DS18B20-PAR TX BIT     0  DS18B20-PAR TX BIT  0

                                                            DS18B20-PAR TX BIT     0  DS18B20-PAR TX BIT  0

                                                                  MASTER TX BIT 0     MASTER TX BIT 0

     DS18B20-PAR TX

     FAMILY CODE

     1 BYTE

                                                N           N                         DEVICE(S)              N

                               BIT 0                                 BIT 0            WITH ALARM

                               MATCH?                             MATCH?              FLAG SET?

     DS18B20-PAR TX

     SERIAL NUMBER                        Y                       Y                        Y

     6 BYTES

                                                            DS18B20-PAR TX BIT     1

     DS18B20-PAR TX     MASTER TX                           DS18B20-PAR TX BIT     1

     CRC BYTE                  BIT 1

                                                                  MASTER TX BIT 1

                                             N              N

                                     BIT 1                           BIT 1

                               MATCH?                             MATCH?

                                     Y                                      Y

                                                            DS18B20-PAR TX BIT 63

                        MASTER TX                           DS18B20-PAR TX BIT 63

                               BIT 63

                                                               MASTER TX BIT 63

                                             N                 N

                               BIT 63                                BIT 63

                               MATCH?                             MATCH?

                                          Y                       Y

                                                          MASTER TX

                                                            FUNCTION

                                                            COMMAND

                                                          (FIGURE 11)

                                                                  11 of  19
                                                                                                                    DS18B20-PAR

DS18B20-PAR  FUNCTION COMMANDS                                 FLOW              CHART  Figure 11

MASTER TX                           44h                                                 48h

                                    CONVERT       N                                     COPY                  N

FUNCTION                         TEMPERATURE                                            SCRATCHPAD

COMMAND                             ?                                                   ?

                                       Y                                                      Y

                                                                                        MASTER ENABLES

                                 MASTER ENABLES                                         STRONG PULL-UP ON DQ

                        STRONG PULLUP ON DQ

                                                                                        DATA COPIED FROM

                        DS18B20-PAR CONVERTS                                        SCRATCHPAD TO EEPROM

                                 TEMPERATURE

                                                                                        MASTER DISABLES

                                 MASTER DISABLES                                        STRONG PULLUP

                                 STRONG PULLUP

N            B8h                                     N             BEh                                    4Eh

             RECALL E2                                             READ                 N                 WRITE

                ?                                                  SCRATCHPAD                    SCRATCHPAD

                                                                   ?                                          ?

                   Y                                                    Y                                        Y

                                                                                              MASTER TX TH BYTE

                                                        MASTER RX DATA BYTE                   TO SCRATCHPAD

             MASTER BEGINS DATA                                FROM SCRATCHPAD

          RECALL FROM E2 PROM

                                                                                             MASTER TX TL BYTE

                                                                                              TO SCRATCHPAD

                                                                   MASTER        Y

                                                                   TX RESET

                                                                   ?

             DEVICE                                                                     MASTER TX CONFIG.           BYTE

             BUSY RECALLING      N                                      N                     TO SCRATCHPAD

             DATA

                ?

             Y                                       N

                                                                   HAVE 8 BYTES

                                                                   BEEN READ

                                                                   ?

             MASTER                 MASTER                              Y

             RX “0s”                RX “1s”

                                                     MASTER RX SCRATCHPAD

                                                                   CRC BYTE

                                         RETURN TO INITIALIZATION

                                       SEQUENCE (FIGURE 10) FOR

                                             NEXT TRANSACTION

                                                     12 of 19
                                                                                            DS18B20-PAR

1-WIRE SIGNALING

The DS18B20-PAR uses a strict 1-Wire communication protocol to insure data integrity. Several signal

types are defined by this protocol: reset pulse, presence pulse, write 0, write 1, read 0, and read 1.     All of

these signals, with the exception of the presence pulse, are initiated by the bus master.

INITIALIZATION PROCEDURE: RESET AND PRESENCE PULSES

All communication with the DS18B20-PAR begins with an initialization sequence that consists of a reset

pulse from the master followed by a presence pulse from the DS18B20-PAR.                    This is illustrated in

Figure 12.  When the DS18B20-PAR sends the presence pulse in response to the reset, it is indicating to

the master that it is on the bus and ready to operate.

During the initialization sequence the bus master transmits (TX) the reset pulse by pulling the 1-Wire bus

low for a minimum of 480 μs. The bus master then releases the bus and goes into receive mode (RX).

When the bus is released, the 5k pullup resistor pulls the 1-Wire bus high.                 When the DS18B20-PAR

detects this rising edge, it waits 15–60 μs and then transmits a presence pulse by pulling the 1-Wire bus

low for 60–240 μs.

INITIALIZATION TIMING  Figure 12

                     MASTER TX RESET PULSE                                   MASTER RX

                     480 μs minimum                                         480 μs minimum

                                                                     DS18B20-PAR TX

                       DS18B20-PAR                                   presence pulse

                       waits 15-60 μs                                60-240 μs

VPU

1-WIRE BUS

GND

                       LINE TYPE LEGEND

                                                    Bus master pulling low

                                                    DS18B20-PAR pulling low

                                                    Resistor pullup

READ/WRITE TIME SLOTS

The bus master writes data to the DS18B20-PAR during write time slots and reads data from the

DS18B20-PAR during read time slots. One bit of data is transmitted over the 1-Wire bus per time slot.

WRITE TIME SLOTS

There are two types of write time slots: “Write 1” time slots and “Write 0” time slots.     The bus master

uses a Write 1 time slot to write a logic 1 to the DS18B20-PAR and a Write 0 time slot to write a logic 0

to the DS18B20-PAR.  All write time slots must be a minimum of 60 μs in duration with a minimum of a

1 μs recovery time between individual write slots.      Both types of write time slots are initiated by the

master pulling the 1-Wire bus low (see Figure 13).

To generate a Write 1 time slot, after pulling the 1-Wire bus low, the bus master must release the 1-Wire

bus within 15 μs. When the bus is released, the 5k pullup resistor will pull the bus high. To generate a

Write 0 time slot, after pulling the 1-Wire bus low, the bus master must continue to hold the bus low for

the duration of the time slot (at least 60 μs).

                                                        13 of 19
                                                                                                                             DS18B20-PAR

The DS18B20-PAR samples the 1-Wire bus during a window that lasts from 15 μs to 60 μs after the

master initiates the write time slot. If the bus is high during the sampling window, a 1 is written to the

DS18B20-PAR. If the line is low, a 0 is written to the DS18B20-PAR.

READ/WRITE                 TIME SLOT TIMING                    DIAGRAM                 Figure 13

                  START                                                       START

                  OF SLOT                                                     OF SLOT

                                  MASTER WRITE “0” SLOT                                       MASTER WRITE    “1”  SLOT

                                                                                       ∞ 1 μs < TREC <

                                  60 μs < TX “0” < 120                                        > 1 μs

     VPU

     1-WIRE BUS

     GND

                                        DS18B20-PAR samples                                           DS18B20-PAR samples

                                  MIN    TYP                    MAX                                   MIN     TYP        MAX

                           15 μs  15 μs                  30 μs                         15 μs          15 μs           30 μs

                                  MASTER READ “0” SLOT                                           MASTER READ “1” SLOT

     VPU                                                                               1 μs   <  ∞ TREC <

     1-WIRE BUS

     GND

                                  Master samples                    > 1 μs                            Master samples

          > 1 μs

                           15 μs         45 μs                                         15 μs

                                  LINE TYPE LEGEND

                                        Bus master pulling low                       DS18B20-PAR pulling low

                                        Resistor pullup

READ TIME SLOTS

The  DS18B20-PAR           can    only  transmit         data   to  the     master     when      the  master  issues     read  time  slots.

Therefore, the master must generate read time slots immediately after issuing a Read Scratchpad [BEh]

command, so that the DS18B20-PAR can provide the requested data. In addition, the master can generate

read time slots after issuing a Recall E2 [B8h] command to find out the recall status as explained in the

DS18B20-PAR FUNCTION COMMAND section.

All read time slots must be a minimum of 60 μs in duration with a minimum of a 1 μs recovery time

between slots.    A read time slot is initiated by the master device pulling the 1-Wire bus low for a

minimum of 1 μs and then releasing the bus (see Figure 13).                            After the master initiates the read time slot,

the DS18B20-PAR will begin transmitting a 1 or 0 on bus. The DS18B20-PAR transmits a 1 by leaving

the bus high and transmits a 0 by pulling the bus low.                        When transmitting a 0, the DS18B20-PAR will

release the bus by the end of the time slot, and the bus will be pulled back to its high idle state by the

pullup resister. Output data from the DS18B20-PAR is valid for 15 μs after the falling edge that initiated

                                                                    14 of 19
                                                                                                           DS18B20-PAR

the read time slot.  Therefore, the master must release the bus and then sample the bus state within 15 μs

from the start of the slot.

Figure 14 illustrates that the sum of TINIT, TRC, and TSAMPLE must be less than 15 μs for a read time slot.

Figure 15 shows that system timing margin is maximized by keeping TINIT and TRC as short as possible

and by locating the master sample time during read time slots towards the end of the 15 μs period.

DETAILED MASTER READ 1 TIMING                         Figure 14

VPU

1-WIRE BUS                                                                  VIH of Master

GND

                              TINT > 1 μs             TRC                         Master samples

                                                      15 μs

RECOMMENDED MASTER READ                            1  TIMING        Figure  15

VPU

1-WIRE BUS                    VIH of Master

GND

               TINT =  TRC =                                                Master  samples

               small   small

                                                      15 μs

                                           LINE TYPE LEGEND

                                                   Bus master pulling low

                                                   Resistor pullup

DS18B20-PAR OPERATION EXAMPLE 1

In this example there are multiple DS18B20-PARs on the bus. The bus master initiates a temperature

conversion in a specific DS18B20-PAR and then reads its scratchpad and recalculates the CRC to verify

the data.

MASTER MODE                  DATA (LSB FIRST)                               COMMENTS

           TX                 Reset                   Master issues reset pulse.

           RX                 Presence                DS18B20-PARs respond with presence pulse.

           TX                 55h                     Master issues Match ROM command.

           TX                 64-bit ROM code         Master sends DS18B20-PAR ROM code.

           TX                 44h                     Master issues Convert T command.

           TX                DQ line held high by     Master applies strong pullup to DQ for the duration  of  the

                              strong pullup           conversion (tconv).

           TX                 Reset                   Master issues reset pulse.

           RX                 Presence                DS18B20-PARs respond with presence pulse.

           TX                 55h                     Master issues Match ROM command.

           TX                 64-bit ROM code         Master sends DS18B20-PAR ROM code.

           TX                 BEh                     Master issues Read Scratchpad command.

                                                      15 of 19
                                                                                                DS18B20-PAR

MASTER MODE  DATA (LSB FIRST)                                  COMMENTS

RX           9 data bytes          Master reads entire scratchpad including CRC. The master

                                   then recalculates the CRC of the first eight data bytes from the

                                   scratchpad and compares the calculated CRC with the read

                                   CRC (byte 9). If they match, the master continues; if not, the

                                   read operation is repeated.

DS18B20-PAR OPERATION EXAMPLE 2

In this example there is only one DS18B20-PAR on the bus. The master writes to the TH, TL, and

configuration registers in the DS18B20-PAR scratchpad and then reads the scratchpad and recalculates

the CRC to verify the data. The master then copies the scratchpad contents to EEPROM.

MASTER MODE  DATA (LSB FIRST)                                  COMMENTS

TX           Reset                 Master issues reset pulse.

RX           Presence              DS18B20-PAR responds with presence pulse.

TX           CCh                   Master issues Skip ROM command.

TX           4Eh                   Master issues Write Scratchpad command.

TX           3 data bytes          Master sends three data bytes to scratchpad (TH, TL, and config).

TX           Reset                 Master issues reset pulse.

RX           Presence              DS18B20-PAR responds with presence pulse.

TX           CCh                   Master issues Skip ROM command.

TX           BEh                   Master issues Read Scratchpad command.

RX           9 data bytes          Master reads entire scratchpad including CRC. The master then

                                   recalculates the CRC of the first eight data bytes from the

                                   scratchpad and compares the calculated CRC with the read CRC

                                   (byte 9). If they match, the master continues; if not, the read

                                   operation is repeated.

TX           Reset                 Master issues reset pulse.

RX           Presence              DS18B20-PAR responds with presence pulse.

TX           CCh                   Master issues Skip ROM command.

TX           48h                   Master issues Copy Scratchpad command.

TX           DQ line held high by  Master applies strong pullup to DQ for at least 10 ms while copy

             strong pullup         operation is in progress.

                                   16 of 19
                                                                                                  DS18B20-PAR

ABSOLUTE MAXIMUM RATINGS*

Voltage on any pin relative to ground            –0.5V to +6.0V

Operating temperature                            –55°C to +100°C

Storage temperature                              –55°C to +125°C

Soldering temperature                            See J-STD-020A Specification

*These are stress ratings only and functional operation of the device at these or any other conditions

    above those indicated in the operation sections of this specification is not implied. Exposure to absolute

    maximum rating conditions for extended periods of time may affect reliability.

DC ELECTRICAL CHARACTERISTICS                                 (-55°C to +100°C; VPU=3.0V to 5.5V)

PARAMETER              SYMBOL               CONDITION         MIN       TYP         MAX   UNITS   NOTES

Pullup Supply          VPU                                    3.0                   5.5       V           1,2

Voltage

Thermometer Error      tERR                 -10°C to +85°C                          ±½        °C                3

                                            -55°C to +100°C                         ±2

Input Logic Low        VIL                                    -0.3                  +0.8      V           1,4,5

Input Logic High       VIH                                    3.0                   5.5       V           1,6

Sink Current           IL                   VI/O=0.4V         4.0                         mA                    1

Active Current         IDQA                                             1           1.5   mA                    7

DQ Input Current       IDQ                                              5                 µA                    8

Drift                                                                   ±0.2                  °C                9

NOTES:

1.  All voltages are referenced to ground.

2.  The Pullup Supply Voltage specification assumes that the pullup device (resistor or transistor) is

    ideal, and therefore the high level of the pullup is equal to VPU.      In order to meet the VIH spec of the

    DS18B20-PAR, the actual supply rail for the strong pullup transistor must include margin for the

    voltage drop across the transistor when it is turned on; thus: VPU_ACTUAL = VPU_IDEAL + VTRANSISTOR.

3.  See typical performance curve in Figure 16.

4.  Logic low voltages are specified at a sink current of 4 mA.

5.  To always guarantee a presence pulse under low voltage parasite power conditions, VILMAX may have

    to be reduced to as low as 0.5V.

6.  Logic high voltages are specified at a source current of 1 mA.

7.  Active current refers to supply current during active temperature conversions or EEPROM writes.

8.  DQ line is high (“hi-Z” state).

9.  Drift data is based on a 1000 hour stress test at 125°C.

AC ELECTRICAL CHARACTERISTICS:                         NV MEMORY

                                                              (-55°C to +100°C; VPU=3.0V to 5.5V)

       PARAMETER       SYMBOL               CONDITION                   MIN   TYP         MAX     UNITS

NV Write Cycle Time                  twr                                            2     10         ms

EEPROM Writes                NEEWR          -55°C to +55°C              50k                       writes

EEPROM Data Retention                tEEDR  -55°C to +55°C              10                        years

                                                 17 of 19
                                                                                                                        DS18B20-PAR

AC ELECTRICAL CHARACTERISTICS                                               (-55°C to +100°C; VPU=3.0V to 5.5V)

PARAMETER                                       SYMBOL   CONDITION           MIN          TYP            MAX        UNITS  NOTES

Temperature Conversion                          tCONV    9-bit resolution                                93.75      ms     1

Time                                                     10-bit resolution                               187.5      ms     1

                                                         11-bit resolution                               375        ms     1

                                                         12-bit resolution                               750        ms     1

Time to Strong Pullup                           tSPON    Start Convert T or                              10         µs

On                                                       Copy Scratchpad

                                                         Command Issued

Time Slot                                       tSLOT                        60                          120        µs     1

Recovery Time                                   tREC                              1                                 µs     1

Write 0 Low Time                                rLOW0                        60                          120        µs     1

Write 1 Low Time                                tLOW1                             1                      15         µs     1

Read Data Valid                                 tRDV                                                     15         µs     1

Reset Time High                                 tRSTH                        480                                    µs     1

Reset Time Low                                  tRSTL                        480                         960        µs     1,2

Presence Detect High                            tPDHIGH                      15                          60         µs     1

Presence Detect Low                             tPDLOW                       60                          240        µs     1

Capacitance                                     CIN/OUT                                                  25         pF

NOTES:

1.  Refer to timing diagrams in Figure 17.

2.  If tRSTL > 960 μs, a power on reset may occur.

TYPICAL                             PERFORMANCE CURVE    Figure 16

                                                         DS18B20-PAR Typical Error Curve

                           0.5

                           0.4

                           0.3

                                                                                          +3σ Error

    Thermometer Error (C)  0.2

                           0.1

                           0

                                 0  10          20       30                  40                      50             60     70

                           -0.1

                           -0.2

                                    Mean Error

                           -0.3

                           -0.4

                                                                                                         -3σ Error

                           -0.5

                                                         Reference  Temp     (C)

                                                         18 of 19
                                      DS18B20-PAR

TIMING DIAGRAMS  Figure 17

                            19 of 19
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory,  Delivery  &  Lifecycle  Information:

Maxim Integrated:

DS18B20-PAR  DS18B20-PAR/T&R

DS18B20-PAR-TR器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved