din rail power supplies industrial power supplies

参数

Manufacturer: Delta
Product Category: DIN Rail Power Supplies
RoHS: Yes
Product: Switching Supplies
Commercial/Medical: Commercial
Output Power Rating: 480 W
Input Voltage: 320 VAC to 600 VAC, 360 VAC to 600 VAC
Number of Outputs: 3
Output Voltage-Channel 1: 24 V
Output Current-Channel 1: 20 A
Output Voltage-Channel 2: 24 V
Output Current-Channel 2: 30 A
Output Voltage-Channel 3: 24 V
Output Current-Channel 3: 40 A
Dimensions: 121 mm L x 140 mm W
Brand: Delta Electronics / Power
Isolation Voltage: 4 kV
Mounting Style: DIN Rail
Open Frame/Enclosed: Enclosed
Output Type: DC

DRP024V480W3BN器件文档内容

TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 480W 3 Phase / DRP024V480W3B

                                                            Highlights & Features

                                                             Universal AC input voltage: 3 x 320Vac 600Vac (3-Phase)
                                                                  or 2 x 360Vac 600Vac (2-Phase)

                                                             Power will not de-rate for the entire input voltage range
                                                             Power Boost of 150% for 5 seconds and 200% for 2 seconds
                                                             Full corrosion resistant aluminium chassis
                                                             Conformal coating on PCBA to protect against chemical and

                                                                  dust pollutants
                                                             Hazardous Locations approval to ATEX and Class I, Div 2

                                                                  (DRP024V480W3BA)

                                                            Safety Standards

                                                            CB Certified for worldwide use

                                                            Model Number:           DRP024V480W3B

                                                            Unit Weight:            1.35 kg

                                                            Dimensions (L x W x D): 121 x 140 x 117.3 mm

General Description

The CliQ II 3-phase DIN rail power supply series offers output voltage of 24V. These products are encased in rugged yet lightweight full
aluminium body that can withstand shock and vibration according to IEC 60068-2 standard. The series of 3-phase products can
operate over a wide temperature range of -25C to +80C. These products also feature universal AC input voltage range for 3-phase
from 320Vac to 600Vac or 2-phase from 360Vac to 600Vac, and the power will not de-rate throughout the entire range. Another great
feature is the conformal coating on the PCBA which allows selected models to be certified to ATEX and Class I, Div 2 for use in
hazardous locations. The design conforms to harmonic current emission IEC/EN 61000-3-2, Class A.

Model Information
CliQ II DIN Rail Power Supply

Model Number                   Input Voltage Range          Output Voltage                  Output Current
DRP024V480W3B                                               24Vdc                           20.0A
                               3 x 320-600Vac (3-Phase) or
                               2 x 360-600Vac (2-Phase)

Model Numbering

DR        P                    024V  480W                   3                       B               
DIN Rail  Power Supply                                      Three Phase             CliQ II Series
                               Output Voltage Output Power                                          A - Metal Case,
                                                                                                         with Class I, Div 2

                                                                                                    N - Metal Case,
                                                                                                         without Class I, Div 2

1         All parameters are specified at 25C ambient unless otherwise indicated.
          www.DeltaPSU.com (May 2014, Rev. 01)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 480W 3 Phase / DRP024V480W3B

Specifications                                          3 x 400-500Vac
Input Ratings / Characteristics                         3 x 320-600Vac (3-Phase) or 2 x 360-600Vac (2-Phase)
                                                        50-60Hz
Nominal Input Voltage                                  47-63Hz
Input Voltage Range                                    450-800Vdc
Nominal Input Frequency                                < 1.00A @ 3 x 400Vac, < 0.75A @ 3 x 500Vac
Input Frequency Range                                  > 91.0% @ 3 x 400Vac & 3 x 500Vac
DC Input Voltage Range*                                < 50A @ 3 x 400Vac & 3 x 500Vac
Input Current                                          > 0.95 @ 3 x 400Vac, > 0.94 @ 3 x 500Vac
Efficiency at 100% Load                                < 3.5mA @ 500Vac
Max Inrush Current (Cold Start)
Power Factor at 100% Load                              24Vdc
Leakage Current                                        2% (initial set point tolerance from factory)
                                                        24-28Vdc
*Safety approval according to IEC/EN/UL 60950-1.        20.0A (continuously operating at 24V)
                                                        30.0A (Power Boost for 5 seconds at 24V, refer to the
Output Ratings / Characteristics                        details in the Functions section)
                                                        40.0A (Power Boost for 2 seconds at 24V, refer to the
Nominal Output Voltage                                 details in the Functions section)
Output Voltage Tolerance                               480W (continuously operating at 24V)
Output Voltage Adjustment Range                        720W (Power Boost for 5 seconds at 24V, refer to the
Output Current                                         details in the Functions section)
                                                        960W (Power Boost for 2 seconds at 24V, refer to the
Output Power                                           details in the Functions section)
                                                        < 0.5% typ. (@ 3 x 320-600Vac input, 100% load)
Line Regulation                                        < 1% typ. (@ 3 x 320-600Vac input, 0-100% load)
Load Regulation                                        < 150mVpp
PARD (20MHz)                                           < 100ms @ nominal input (100% load)
Rise Time                                              < 1,000ms @ nominal input (100% load)
Start-up Time                                          > 20ms @ 3 x 400Vac & 3 x 500Vac (100% load)
Hold-up Time                                           5% @ 10-90% load
Dynamic Response (Overshoot & Undershoot O/P Voltage)  10,000F Max
Start-up with Capacitive Loads

2  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 01)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 480W 3 Phase / DRP024V480W3B

Mechanical                            Input              Aluminium
Case Cover / Chassis               Output               121 x 140 x 117.3 mm
Dimensions (L x W x D)                                  1.35 kg
Unit Weight                          Input              Green LED (DC OK)
Indicator                          Output               Convection
Cooling System                                          4 Pins (Rated 600V/35A)
Terminal                                                4 Pins (Rated 300V/30A)
                                                         AWG 18-8
Wire                                                    AWG 12-10
                                                         Standard TS35 DIN Rail in accordance with EN 60715
Mounting Rail                                           Sound Pressure Level (SPL) < 40dBA
Noise (1 Meter from power supply)
                                              Operating  -25C to +80C (Cold Start at -40C)
Environment                                     Storage
Surrounding Air Temperature                             -40C to +85C
                                    Vertical Mounting
Power De-rating                                         > 50C de-rate power by 2.5% / C,
Operating Humidity                                      > 70C de-rate power by 5% / C
Operating Altitude
Shock Test (Non-Operating)                              5 to 95% RH (Non-Condensing)
Vibration (Non-Operating)
Pollution Degree                                        0 to 2,500 Meters for ITE application (@ 50C)
                                                         0 to 2,000 Meters for Industrial application (@ 50C)
Protections
Overvoltage                                             IEC 60068-2-27, 30G (300m/S) for a duration of 18ms,
Overload / Overcurrent                                  1 time per direction, 2 times in total
Over Temperature
Short Circuit                                           IEC 60068-2-6, 10Hz to 500Hz @ 30m/S (3G peak);
Degree of Protection                                    60 min per axis for all X, Y, Z direction
Protection Against Shock
                                                         2
*PE: Primary Earth
                                                         32V 10%, SELV Output, Hiccup Mode,
                                                         Non-Latching (Auto-Recovery)

                                                         > 200% of rated load current, Hiccup Mode,
                                                         Non-Latching (Auto-Recovery)

                                                         < 80C Surrounding Air Temperature @ 100% load,
                                                         Non-Latching (Auto-Recovery)

                                                         Hiccup Mode, Non-Latching
                                                         (Auto-Recovery when the fault is removed)

                                                         IP20

                                                         Class I with PE* connection

3  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 01)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 480W 3 Phase / DRP024V480W3B

Reliability Data                                                  > 500,000 hrs. as per Telcordia SR-332
MTBF                                                             I/P: 3 x 400Vac, O/P: 100% load, Ta: 25C
Expected Cap Life Time
Safety Standards / Directives                                     10 years (3 x 400Vac & 3x 500Vac, 50% load @ 40C)
Electrical Equipment in Power Installations
Electrical Safety                                                EN 50178 / IEC 62103
Industrial Control Equipment
Hazardous Location / ATEX (DRP024V480W3BA)                       SIQ to EN 60950-1, UL/cUL recognized to UL 60950-1
                                                                  and CSA C22.2 No. 60950-1, CB scheme to
     II 3G ATEX 94/9/EC (DRP024V480W3BA)                          IEC 60950-1
CE
                                                                  UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01,
Material and Parts                                               CSA to CSA C22.2 No. 107.1-01 (File No. 181564)
Galvanic Isolation
                                                                  cCSAus to CSA C22.2 No. 213-M1987, ANSI / ISA
                                                                  12.12.01:2007 [Class I, Division 2, Group A, B, C, D T4,
                                                                  Ta = -25C to +80C (> +50C derating)]

                                                                  EN 60079-0:2012, EN 60079-15:2010 [ II 3G Ex nA
                                                                  IIC T4 Gc, Ta= -25C to +80C (> +50C derating)]
                                                                  Certificate No. EPS 13 ATEX 1 575 X

                                                                  In conformance with EMC Directive 2004/108/EC and
                                                                  Low Voltage Directive 2006/95/EC

                                                 Input to Output  DRP024V480W3BA:
                                                Input to Ground   In conformance with Equipment for explosive
                                              Output to Ground    atmospheres (ATEX) directive 94/9/EC
                                                                  RoHS Directive 2011/65/EU Compliant

                                                                  4.0KVac

                                                                  2.0KVac

                                                                  1.5KVac

4  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 01)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 480W 3 Phase / DRP024V480W3B

EMC                                                                 IEC 61000-4-2  CISPR 22, EN 55022, CISPR 11, EN 55011,
EMC / Emissions                                                    IEC 61000-4-3  FCC Title 47: Class B
Component Power Supply for General Use
Immunity to                                                        IEC 61000-4-4  EN 61204-3
                                                                    IEC 61000-4-5
         Electrostatic Discharge                                    IEC 61000-4-6  EN 55024, EN 61000-6-2
                                                                    IEC 61000-4-8  Level 4 Criteria A1)
         Radiated Field                                            IEC 61000-4-11  Air Discharge: 15kV
                                                                                   Contact Discharge: 8kV
         Electrical Fast Transient / Burst
         Surge                                                                     Level 3 Criteria A1)
                                                                                   80MHz-1GHz, 10V/M, 80% modulation (1KHz)
         Conducted                                                                 1.4GHz-2GHz, 3V/M, 80% modulation (1KHz)
         Power Frequency Magnetic Fields                                           2GHz-2.7GHz, 1V/M, 80% modulation (1KHz)
         Voltage Dips                                                              Level 3 Criteria A1)
         Low Energy Pulse Test (Ring Wave)                                         2kV
                                                                                   Level 3 Criteria A1)
Harmonic Current Emission                                                         Common Mode2): 2kV
Voltage Fluctuation and Flicker                                                   Differential Mode3): 1kV

1) Criteria A: Normal performance within the specification limits                  Level 3 Criteria A1)
2) Asymmetrical: Common mode (Line to earth)                                       150kHz-80MHz, 10Vrms
3) Symmetrical: Differential mode (Line to line)
                                                                                   Criteria A1)
                                                                                   30A/Meter

                                                                                   100% dip; 1 cycle (20ms); Self Recoverable

                                                                   IEC 61000-4-12  Level 3 Criteria A1)
                                                                                   Common Mode2): 2kV
                                                                                   Differential Mode3): 1kV
                                                                                   IEC/EN 61000-3-2, Class A
                                                                                   IEC/EN 61000-3-3

5  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 01)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 480W 3 Phase / DRP024V480W3B

Block Diagram

Device Description

1) Input terminal block connector
2) Output terminal block connector
3) DC Voltage adjustment potentiometer
4) DC OK control LED (Green)
5) Universal mounting rail system

6  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 01)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 480W 3 Phase / DRP024V480W3B

Dimensions
L x W x D: 121 x 140 x 117.3 mm

Engineering Data                                                             Note
De-rating
                                                                             1. Power supply components may degrade, or
    Fig. 1 De-rating for Vertical Mounting Orientation                             be damaged, when the power supply is
                > 50C de-rate power by 2.5% / C,                                 continuously used outside the shaded region,
                > 70C de-rate power by 5% / C                                    refer to the graph shown in Fig. 1.

                                                                             2. If the output capacity is not reduced when the
                                                                                   surrounding air temperature >50C (Vertical),
                                                                                   the device may run into Over Temperature
                                                                                   Protection. When activated, the output
                                                                                   voltage will go into bouncing mode and will
                                                                                   recover when the surrounding air
                                                                                   temperature is lowered or the load is reduced
                                                                                   as far as necessary to keep the device in
                                                                                   working condition.

                                                                             3. In order for the device to function in the
                                                                                   manner intended, it is also necessary to keep
                                                                                   a safety distance of 5mm (for Vertical
                                                                                   Mounting) with adjacent units while the
                                                                                   device is in operation.

                                                                             4. Depending on the surrounding air
                                                                                   temperature and output load delivered by the
                                                                                   power supply, the device can be very hot!

                                                                             5. If the device has to be mounted in any other
                                                                                   orientation, please do not hesitate to contact
                                                                                   info@deltapsu.com for more details.

7  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 01)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 480W 3 Phase / DRP024V480W3B

Output De-rating VS. Input Voltage

                                                                              No output power de-rating across the entire
                                                                                    input voltage range 3 x 320-600Vac
                                                                                    (3-Phase) or 2 x 360-600Vac (2-Phase)

Assembly & Installation
The power supply unit (PSU) can be mounted on 35mm DIN rails in accordance with EN 60715. For Vertical Mounting, the device
should be installed with input terminal block at the bottom.

Each device is delivered ready to install.

Mounting                                                   Dismounting

Fig. 2.1 Mounting                                          Fig. 2.2 Dismounting

Snap on the DIN rail as shown in Fig. 2.1:                 To uninstall, pull or slide down the latch with screw driver as
1. Tilt the unit upwards and insert it onto the DIN rail.  shown in Fig. 2.2. Then slide the power supply unit (PSU) in
2. Push downwards until stopped.                           the opposite direction, release the latch and pull out the power
3. Press against the bottom front side for locking.        supply unit (PSU) from the rail.
4. Shake the unit slightly to ensure that it is secured.

In accordance to EN 60950 / UL 50950, flexible cables require ferrules.
Use appropriate copper cables designed to sustain operating temperature of:
1. 60C, 60C / 75C for USA
2. At least 75C for ambient not exceeding 50C, and 90C for ambient exceeding 50C for Canada.

8  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 01)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 480W 3 Phase / DRP024V480W3B

Safety Instructions                                                           Horizontal Mounting
Vertical Mounting

ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit. If mains are not
      turned OFF, there is risk of explosion / severe damage.

To guarantee sufficient convection cooling, keep a distance of 50mm above and below the device as well as a lateral
      distance of 5mm to other units.

Note that the enclosure of the device can become very hot depending on the surrounding air temperature and load of the power
      supply. Risk of burns!

Only plug in and unplug connectors when power is turned off!
DO NOT insert any objects into the unit.
Hazardous voltages may be present for up to 5 minutes after the input mains voltage is disconnected. Do not touch the unit during

      this time.
The power supplies unit should be installed in minimum IP54 rated enclosure.
The power supplies are built in units and must be installed in a cabinet or room (condensation free environment and indoor

      location) that is relatively free of conductive contaminants.
CAUTION: "For use in a controlled environment".
It is NOT advised to install in horizontal mounting orientation, since it may cause damage to the PSU.

For DRP024V480W3BA:
The power supplies unit must be installed in an IP54 enclosure or cabinet in the final installation. The enclosure or cabinet must

      comply with EN60079-0 or EN60079-15.
Warning: Explosion Hazard - Substitution of components may impair suitability for Class I, Division 2.
Warning: Explosion Hazard - Do not disconnect equipment or adjust potentiometer unless the power has been switched off or the

      area is known to be non-hazardous.

9  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 01)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 480W 3 Phase / DRP024V480W3B

Functions
Graph illustrating the Start-up Time, Rise Time, and Hold-up Time

Start-up Time
The time required for the output voltage to reach 90% of its set value, after the input voltage is applied.

Rise Time
The time required for the output voltage to change from 10% to 90% of its set value.

Hold-up Time

Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time
required for the output to reach 90% of its set value, after the input voltage is removed.

Inrush Current                                                     Dynamic Response

Inrush current is the peak, instantaneous, input current measured  The power supply output voltage will remains within 5% of its
and, occurs when the input voltage is first applied. For AC input  steady state value, when subjected to a dynamic load from 10 to
voltages, the maximum peak value of inrush current will occur      90% of its rated current.
during the first half cycle of the applied AC voltage. This peak
value decreases exponentially during subsequent cycles of AC
voltage.

10  All parameters are specified at 25C ambient unless otherwise indicated.
    www.DeltaPSU.com (May 2014, Rev. 01)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 480W 3 Phase / DRP024V480W3B

Power Boost

Power Boost is the reserve power available
constantly that allows reliable startup to
support sudden and short spike of loads
with high inrush current typically during turn
on to remove the need of more expensive
higher rated power supply unit. After the
output has reached its steady state set
value, the power supply can support surge
loads with a higher short-term power
demand up to 200% of maximum rated load
(IO Max), for a maximum duration of 2
seconds, or 150% of maximum rated load
for a maximum duration of 5 seconds. The
Power Boost is also available to repeatedly
basis with according to the condition of an
average (R.M.S) output power shall not
exceed continuous operating condition or
refer to duty cycle calculation below.

      (%) =            
                  

                                                (    ) + (-   )
       () =                                             

              OR

    -             =            - (                            )
                                               

An example of Power Boost and Average Output Power

Power Boost    Peak Power   Power Boost          Duty Cycle     Non-Peak     Non-Peak Power       Total Time
                     (WP)    Duration (TP)                     Power (WN)       Duration (TN)            (T)
200%                        2 sec               5%            455W
150%          960           5 sec               10%           453W            38 sec           40 sec
150%          720           5 sec               35%           351W            45 sec           50 sec
120%          720           10 sec              20%           456W            9.3 sec          14.3 sec
120%          576           10 sec              35%           428W            40 sec           50 sec
              576                                                             18.5 sec         28.5 sec

It is not recommended to prolong the duration of Power Boost to be longer than the specified duty cycle calculation, this may cause
damage to the PSU.

11  All parameters are specified at 25C ambient unless otherwise indicated.
    www.DeltaPSU.com (May 2014, Rev. 01)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 480W 3 Phase / DRP024V480W3B

Overload & Overcurrent Protections                                    Overvoltage Protection

The power supply's Overload (OLP) and Overcurrent (OCP)               The power supply's overvoltage circuit will be activated when its
Protections will be activated when output current exceeds 200%        internal feedback circuit fails. The output voltage shall not exceed
of IO (Max load). In such occurrence, the VO will start to droop and  its specifications defined on Page 3 under "Protections".
once the power supply has reached its maximum power limit, the
protection is activated and the power supply will go into "Hiccup
mode" (Auto-Recovery). The power supply will recover once the
fault condition of the OLP and OCP is removed and IO is back
within the specifications.

It is not recommended to prolong the duration of IO when it is        Over Temperature Protection
<200% but >100%, since it may cause damage to the PSU.
                                                                      As mentioned above, the power supply also has Over
Short Circuit Protection                                              Temperature Protection (OTP). In the event of a higher operating
                                                                      temperature at 100% load, the power supply will run into OTP
The power supply's output OLP/OCP function also provides              when the operating temperature is beyond what is recommended
protection against short circuits. When a short circuit is applied,   in the de-rating graph. When activated, the output voltage will go
the output current will operate in "Hiccup mode", as shown in the     into bouncing mode until the temperature drops to its normal
illustration in the OLP/OCP section on this page. The power           operating temperature as recommended in the de-rating graph.
supply will return to normal operation after the short circuit is
removed.

12  All parameters are specified at 25C ambient unless otherwise indicated.
    www.DeltaPSU.com (May 2014, Rev. 01)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 480W 3 Phase / DRP024V480W3B

Operating Mode

Fig. 3 Redundancy / Parallel Operation Connection Diagram

Redundancy Operation
In order to ensure proper redundancy operation for the power supply unit (PSU), ensure that the output voltage difference between the
two units is kept at 0.45~0.50V for 24V supplies. Follow simple steps given below to verify:

Step 1.
Measure output voltage of PSU 1 and PSU 2. If PSU 1 is the master unit, then VO of PSU 1 must be higher than PSU 2.

In order to set the output voltage, connect the power supply to 50% load and set the PSU 1 and PSU 2 output voltage.

Step 2.
Connect the right DRR module, 40A as per the system requirement to the power supply units PSU 1 and PSU 2 at Vin 1 & Vin 2
respectively.

Step 3.
Connect the system load from Vout. Please note that output voltage Vout from DRR module will be = VO (output voltage of power
supply) Vdrop* (in DRR module).

Parallel Operation
These DRR modules can also be used for Parallel function in order to increase the output power by N+1 (e.g. 2.5A + 2.5A = 5A or 2.5A
+ 2.5A + 2.5A = 7.5A) or current sharing, and thus increasing the power supply and system reliability. Though the DRP024V480W3B
is not designed for current sharing, a good current sharing between two power supplies can be achieved by following simple steps as
below (Refer to Fig. 3 for the Connection Diagram).

Step 1.                                                         Step 3.
Set output load condition for both supplies at 50% and measure  Connect PSU 1 and PSU 2 with the DRR-40A module and
the output voltages.                                            measure at Vin 1 & Vin 2 to verify the voltage difference. Ensure
                                                                the voltages are within 25mV.
Step 2.
Adjust output voltages to the same level or within 25mV        Step 4.
difference.                                                     Output voltage from DRR module Vout will be = VO (output
                                                                voltage of power supply) Vdrop* (in DRR module).

*Vdrop will vary from 0.60V to 0.90V (Typical 0.65V) depending on the load current and surrounding air temperature.

13  All parameters are specified at 25C ambient unless otherwise indicated.
    www.DeltaPSU.com (May 2014, Rev. 01)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 480W 3 Phase / DRP024V480W3B

Others
Delta RoHS Compliant

                               Restriction of the usage of hazardous substances
                               The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead,
                               mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and
                               electronic equipment. RoHS is the abbreviation for "Restriction of the use of certain hazardous substances in
                               electrical and electronic equipment".
                               This product conforms to this standard.

Conformal Coating
                               The Protective Coating Technology
                               Delta Electronics Group has designed the perfect dipping technique which penetrates everywhere including
                               under device, and prevents leakage. The conformal coating dipping can be applied to PCBAs or circuit board.
                               The coating preserves the performance of precision electronic primarily by preventing ionizable contaminants
                               such as salt from reaching circuit nodes, where the material slumps around sharp edges. This can be a problem
                               especially in highly conversing atmosphere.

PFC Norm EN 61000-3-2
                               Line Current Harmonic content
                               Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor.
                               In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying
                               to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial
                               aspects such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard,
                               therefore, it is important to know whether it is mandatory to meet this standard for a specific application.

14  All parameters are specified at 25C ambient unless otherwise indicated.
    www.DeltaPSU.com (May 2014, Rev. 01)
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Delta:

  DRP024V480W3BN
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company

小广播

DRP024V480W3BN器件购买:

数量 单价(人民币) mouser购买
1 ¥1,037.25 购买
5 ¥1,005.41 购买
10 ¥973.51 购买
25 ¥941.47 购买
50 ¥909.57 购买
100 ¥877.66 购买
250 ¥860.66 购买

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved