器件描述

din rail power supplies industrial power supplies

参数

Manufacturer: Delta
Product Category: DIN Rail Power Supplies
RoHS: Yes
Product: Switching Supplies
Commercial/Medical: Commercial
Output Power Rating: 120 W
Input Voltage: 320 VAC to 600 VAC, 360 VAC to 600 VAC
Number of Outputs: 3
Output Voltage-Channel 1: 24 V
Output Current-Channel 1: 5 A
Output Voltage-Channel 2: 24 V
Output Current-Channel 2: 7.5 A
Dimensions: 121 mm L x 50 mm W
Brand: Delta Electronics / Power
Isolation Voltage: 4 kV
Mounting Style: DIN Rail
Open Frame/Enclosed: Enclosed
Output Type: DC

DRP024V120W3BN器件文档内容

TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 120W 3 Phase / DRP024V120W3B

                                                            Highlights & Features

                                                             Universal AC input voltage: 3 x 320Vac 600Vac (3-Phase)
                                                                  or 2 x 360Vac 600Vac (2-Phase)

                                                             Power will not de-rate for the entire input voltage range
                                                             Power Boost of 150% for 5 seconds
                                                             Full corrosion resistant aluminium chassis
                                                             Conformal coating on PCBA to protect against chemical and

                                                                  dust pollutants
                                                             Hazardous Locations approval to ATEX and Class I, Div 2

                                                                  (DRP024V120W3BA)

                                                            Safety Standards

                                                            CB Certified for worldwide use

                                                            Model Number:           DRP024V120W3B

                                                            Unit Weight:            0.66 kg

                                                            Dimensions (L x W x D): 121 x 50 x 117.3 mm

General Description

The CliQ II 3-phase DIN rail power supply series offers output voltage of 24V. These products are encased in rugged yet lightweight full
aluminium body that can withstand shock and vibration according to IEC 60068-2 standard. The series of 3-phase products can
operate over a wide temperature range of -25C to +80C. These products also feature universal AC input voltage range for 3-phase
from 320Vac to 600Vac or 2-phase from 360Vac to 600Vac, and the power will not de-rate throughout the entire range. Another great
feature is the conformal coating on the PCBA which allows selected models to be certified to ATEX and Class I, Div 2 for use in
hazardous locations. The design conforms to harmonic current emission IEC/EN 61000-3-2, Class A.

Model Information
CliQ II DIN Rail Power Supply

Model Number                   Input Voltage Range          Output Voltage                  Output Current
DRP024V120W3B                                               24Vdc                           5.00A
                               3 x 320-600Vac (3-Phase) or
                               2 x 360-600Vac (2-Phase)

Model Numbering

DR        P                    24V  120W                    3                       B               
DIN Rail  Power Supply                                      Three Phase             CliQ II Series
                               Output Voltage Output Power                                          A - Metal Case,
                                                                                                         with Class I, Div 2

                                                                                                    N - Metal Case,
                                                                                                         without Class I, Div 2

1         All parameters are specified at 25C ambient unless otherwise indicated.
          www.DeltaPSU.com (May 2014, Rev. 02)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 120W 3 Phase / DRP024V120W3B

Specifications                                             3 x 400-500Vac
Input Ratings / Characteristics                            3 x 320-600Vac (3-Phase) or 2 x 360-600Vac (2-Phase)
                                                           50-60Hz
Nominal Input Voltage                                     47-63Hz
Input Voltage Range*                                      450-800Vdc
Nominal Input Frequency                                   < 0.50A @ 3 x 400Vac, < 0.40A @ 3 x 500Vac
Input Frequency Range                                     > 88.0% @ 3 x 400Vac & 3 x 500Vac
DC Input Voltage Range**                                  < 30A @ 3 x 400Vac & 3 x 500Vac
Input Current                                             < 3.5mA @ 500Vac
Efficiency at 100% Load
Max Inrush Current (Cold Start)                           24Vdc
Leakage Current                                           2% (initial set point tolerance from factory)
                                                           24-28Vdc
*Fulfills test conditions for up to 600Vac input voltage.  5.00A (continuously operating at 24V)
**Fulfills the test conditions for this range.             7.50A (Power Boost for 5 seconds at 24V, refer to the
                                                           details in the Functions section)
Output Ratings / Characteristics                           120W (continuously operating at 24V)
                                                           180W (Power Boost for 5 seconds at 24V, refer to the
Nominal Output Voltage                                    details in the Functions section)
Output Voltage Tolerance                                  < 0.5% typ. (@ 320-600Vac input, 100% load)
Output Voltage Adjustment Range                           < 1% typ. (@ 320-600Vac input, 0-100% load)
Output Current                                            < 150mVpp
                                                           < 100ms @ nominal input (100% load)
Output Power                                              < 1,000ms @ nominal input (100% load)
                                                           > 20ms @ 3 x 400Vac,
Line Regulation                                           > 40ms @ 3 x 500Vac (100% load)
Load Regulation                                           5% @ 0-100% load
PARD (20MHz)                                              10,000F Max
Rise Time
Start-up Time
Hold-up Time

Dynamic Response (Overshoot & Undershoot O/P Voltage)
Start-up with Capacitive Loads

2  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 02)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 120W 3 Phase / DRP024V120W3B

Mechanical                                     Input         Aluminium
Case Cover / Chassis                        Output          121 x 50 x 117.3 mm
Dimensions (L x W x D)             Input / Output           0.66 kg
Unit Weight                                                 Green LED (DC OK)
Indicator                                                   Convection
Cooling System                                              4 Pins (Rated 600V/35A)
Terminal                                                    4 Pins (Rated 300V/28A)
                                                             AWG 18-12
Wire                                                        Standard TS35 DIN Rail in accordance with EN 60715
Mounting Rail                                               Sound Pressure Level (SPL) < 40dBA
Noise (1 Meter from power supply)
                                                 Operating   -25C to +80C (Cold Start at -40C)
Environment                                         Storage
Surrounding Air Temperature                                 -40C to +85C
                                       Vertical Mounting
Power De-rating                                             > 50C de-rate power by 2.5% / C,
                                    Horizontal Mounting      > 70C de-rate power by 5% / C
Operating Humidity
Operating Altitude                                          > 40C de-rate power by 2.5% / C,
Shock Test (Non-Operating)                                  > 60C de-rate power by 5% / C
Vibration (Non-Operating)
Pollution Degree                                            5 to 95% RH (Non-Condensing)

Protections                                                  0 to 2,500 Meters for ITE application (@ 50C)
Overvoltage                                                 0 to 2,000 Meters for Industrial application (@ 50C)
Overload / Overcurrent
Over Temperature                                            IEC 60068-2-27, 30G (300m/S) for a duration of 18ms,
Short Circuit                                               1 times per direction, 2 times in total
Degree of Protection
Protection Against Shock                                    IEC 60068-2-6, 10Hz to 500Hz @ 30m/S (3G peak);
                                                             60 min per axis for all X, Y, Z direction
*PE: Primary Earth
                                                             2

                                                             32V 10%, SELV Output, Hiccup Mode,
                                                             Non-Latching (Auto-Recovery)

                                                             > 150% of rated load current, Hiccup Mode,
                                                             Non-Latching (Auto-Recovery)

                                                             < 80C Surrounding Air Temperature @ 100% load,
                                                             Non-Latching (Auto-Recovery)

                                                             Hiccup Mode, Non-Latching
                                                             (Auto-Recovery when the fault is removed)

                                                             IP20

                                                             Class I with PE* connection

3  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 02)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 120W 3 Phase / DRP024V120W3B

Reliability Data                                                    > 800,000 hrs. as per Telcordia SR-332
MTBF                                                               I/P: 3 x 400Vac, O/P: 100% load, Ta: 25C
Expected Cap Life Time
                                                                    10 years (3 x 400Vac & 3 x 500Vac, 50% load @ 40C)

Safety Standards / Directives

Electrical Equipment in Power Installations                         EN 50178 / IEC 62103
Electrical Safety
                                                                    SIQ to EN 60950-1, UL/cUL recognized to UL 60950-1
Industrial Control Equipment                                        and CSA C22.2 No. 60950-1, CB scheme to
Hazardous Location / ATEX (For DRP024V120W3BA)                      IEC 60950-1

                                                                    UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01,
                                                                    CSA to CSA C22.2 No. 107.1-01 (File No. 181564)

                                                                    cCSAus to CSA C22.2 No. 213-M1987, ANSI / ISA
                                                                    12.12.01:2007 [Class I, Division 2, Group A, B, C, D T4,
                                                                    Ta = -25C to +80C for Vertical (> +50C derating) and
                                                                    -25C to +70C for Horizontal (> +40C derating)]

    II 3G ATEX 94/9/EC (For DRP024V120W3BA)                         EN 60079-0:2012, EN 60079-15:2010 [ II 3G Ex nA
CE                                                                  IIC T4 Gc, Ta= -25C to +80C for Vertical (> +50C
                                                                    derating) and -25C to +70C for Horizontal (> +40C
                                                                    derating)]

                                                                    Certificate No. EPS 13 ATEX 1 575 X

                                                                    In conformance with EMC Directive 2004/108/EC and
                                                                    Low Voltage Directive 2006/95/EC

Material and Parts                                 Input to Output  For DRP024V120W3BA:
Galvanic Isolation                                Input to Ground   In conformance with Equipment for explosive
                                                Output to Ground    atmospheres (ATEX) directive 94/9/EC
                                                                    RoHS Directive 2011/65/EU Compliant

                                                                    4.0KVac

                                                                    2.0KVac

                                                                    1.5KVac

4  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 02)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 120W 3 Phase / DRP024V120W3B

EMC                                                                 IEC 61000-4-2  CISPR 22, EN 55022, CISPR 11, EN 55011,
EMC / Emissions                                                                   FCC Title 47: Class B
                                                                    IEC 61000-4-3
Component Power Supply for General Use                             IEC 61000-4-4  EN 61204-3
Immunity to                                                        IEC 61000-4-5
                                                                                   EN 55024, EN 61000-6-2
         Electrostatic Discharge                                    IEC 61000-4-6  Level 4 Criteria A1)
                                                                    IEC 61000-4-8  Air Discharge: 15kV
         Radiated Field                                            IEC 61000-4-11  Contact Discharge: 8kV
                                                                   IEC 61000-4-12  Level 3 Criteria A1)
         Electrical Fast Transient / Burst                                         80MHz-1GHz, 10V/M, 80% modulation (1kHz)
                                                                                   Level 3 Criteria A1)
         Surge                                                                     2kV
                                                                                   Level 3 Criteria A1)
         Conducted                                                                 Common Mode2): 2kV
                                                                                   Differential Mode3): 1kV
         Power Frequency Magnetic Fields                                           Level 3 Criteria A1)
                                                                                   150kHz-80MHz, 10Vrms
         Voltage Dips                                                              Criteria A1)
         Low Energy Pulse Test (Ring Wave)                                         10A/Meter

Harmonic Current Emission                                                         100% dip; 1 cycle (20ms); Self Recoverable
Voltage Fluctuation and Flicker                                                   Level 3 Criteria A1)
                                                                                   Common Mode2): 2kV
1) Criteria A: Normal performance within the specification limits                  Differential Mode3): 1kV
2) Asymmetrical: Common mode (Line to earth)
3) Symmetrical: Differential mode (Line to line)                                   IEC/EN 61000-3-2, Class A

                                                                                   IEC/EN 61000-3-3

5  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 02)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 120W 3 Phase / DRP024V120W3B

Block Diagram

Device Description

1) Input terminal block connector
2) Output terminal block connector
3) DC Voltage adjustment potentiometer
4) DC OK control LED (Green)
5) Universal mounting rail system

6  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 02)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 120W 3 Phase / DRP024V120W3B

Dimensions
L x W x D: 121 x 50 x 117.3 mm

Engineering Data                                                             Note
De-rating
                                                                             1. Power supply components may degrade, or
    Fig. 1 De-rating for Vertical Mounting Orientation                             be damaged, when the power supply is
                > 50C de-rate power by 2.5% / C,                                 continuously used outside the shaded region,
                > 70C de-rate power by 5% / C                                    refer to the graph shown in Fig. 1.
                De-rating for Horizontal Mounting Orientation
                > 40C de-rate power by 2.5% / C,                           2. If the output capacity is not reduced when the
                > 60C de-rate power by 5% / C                                    surrounding air temperature >50C (Vertical)
                                                                                   or >40C (Horizontal), the device may run
                                                                                   into Over Temperature Protection. When
                                                                                   activated, the output voltage will go into
                                                                                   bouncing mode and will recover when the
                                                                                   surrounding air temperature is lowered or the
                                                                                   load is reduced as far as necessary to keep
                                                                                   the device in working condition.

                                                                             3. In order for the device to function in the
                                                                                   manner intended, it is also necessary to keep
                                                                                   a safety distance of 5mm with adjacent units
                                                                                   while the device is in operation.

                                                                             4. Depending on the surrounding air
                                                                                   temperature and output load delivered by the
                                                                                   power supply, the device can be very hot!

                                                                             5. If the device has to be mounted in any other
                                                                                   orientation, please do not hesitate to contact
                                                                                   info@deltapsu.com for more details.

7  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 02)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 120W 3 Phase / DRP024V120W3B

Output De-rating VS. Input Voltage

                                                                              No output power de-rating across the entire
                                                                                    input voltage range 3 x 320-600Vac
                                                                                    (3-Phase) or 2 x 360-600Vac (2-Phase)

Assembly & Installation
The power supply unit (PSU) can be mounted on 35mm DIN rails in accordance with EN 60715. For Vertical Mounting, the device
should be installed with input terminal block at the bottom. For Horizontal Mounting, the device should be installed with input terminal
block on the left side.

Each device is delivered ready to install.

Mounting                                                   Dismounting

Fig. 2.1 Mounting                                          Fig. 2.2 Dismounting

Snap on the DIN rail as shown in Fig. 2.1:                 To uninstall, pull or slide down the latch with screw driver as
1. Tilt the unit upwards and insert it onto the DIN rail.  shown in Fig. 2.2. Then slide the power supply unit (PSU) in
2. Push downwards until stopped.                           the opposite direction, release the latch and pull out the power
3. Press against the bottom front side for locking.        supply unit (PSU) from the rail.
4. Shake the unit slightly to ensure that it is secured.

In accordance to EN 60950 / UL 50950, flexible cables require ferrules.
Use appropriate copper cables designed to sustain operating temperature of:
1. 60C, 60C / 75C for USA
2. At least 75C for ambient not exceeding 50C, and 90C for ambient exceeding 50C for Canada.

8  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 02)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 120W 3 Phase / DRP024V120W3B

Safety Instructions   Horizontal Mounting
Vertical Mounting

ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit. If mains are not
      turned OFF, there is risk of explosion / severe damage.

To guarantee sufficient convection cooling, keep a distance of 50mm above and below the device as well as a lateral
      distance of 5mm (for Vertical Mounting) or 50mm (for Horizontal Mounting) to other units.

Note that the enclosure of the device can become very hot depending on the surrounding air temperature and load of the power
      supply. Risk of burns!

Only plug in and unplug connectors when power is turned off!
DO NOT insert any objects into the unit.
Hazardous voltages may be present for up to 5 minutes after the input mains voltage is disconnected. Do not touch the unit during

      this time.
The power supplies unit should be installed in minimum IP54 rated enclosure.
The power supplies are built in units and must be installed in a cabinet or room (condensation free environment and indoor

      location) that is relatively free of conductive contaminants.
CAUTION: "For use in a controlled environment".

For DRP024V120W3BA:
The power supplies unit must be installed in an IP54 enclosure or cabinet in the final installation. The enclosure or cabinet must

      comply with EN60079-0 or EN60079-15.
Warning: Explosion Hazard - Substitution of components may impair suitability for Class I, Division 2.
Warning: Explosion Hazard - Do not disconnect equipment or adjust potentiometer unless the power has been switched off or the

      area is known to be non-hazardous.

9  All parameters are specified at 25C ambient unless otherwise indicated.
   www.DeltaPSU.com (May 2014, Rev. 02)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 120W 3 Phase / DRP024V120W3B

Functions
Graph illustrating the Start-up Time, Rise Time, and Hold-up Time

Start-up Time
The time required for the output voltage to reach 90% of its set value, after the input voltage is applied.

Rise Time
The time required for the output voltage to change from 10% to 90% of its set value.

Hold-up Time

Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time
required for the output to reach 90% of its set value, after the input voltage is removed.

Inrush Current                                                     Dynamic Response

Inrush current is the peak, instantaneous, input current measured  The power supply output voltage will remains within 5% of its
and, occurs when the input voltage is first applied. For AC input  steady state value, when subjected to a dynamic load from 0 to
voltages, the maximum peak value of inrush current will occur      100% of its rated current.
during the first half cycle of the applied AC voltage. This peak
value decreases exponentially during subsequent cycles of AC
voltage.

10  All parameters are specified at 25C ambient unless otherwise indicated.
    www.DeltaPSU.com (May 2014, Rev. 02)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 120W 3 Phase / DRP024V120W3B

Power Boost

Power Boost is the reserve power available
constantly that allows reliable startup to support
sudden and short spike of loads with high inrush
current typically during turn on to remove the
need of more expensive higher rated power
supply unit. After the output has reached its
steady state set value, the power supply can
support surge loads with a higher short-term
power demand up to 150% of maximum rated
load (IO Max), for a maximum duration of 5
seconds. The Power Boost is also available to
repeatedly basis with according to the condition of
an average (R.M.S) output power shall not
exceed continuous operating condition or refer to
duty cycle calculation below.

      (%) =            
                  

                                                (    ) + (-   )
       () =                                             

              OR

    -             =            - (                                 )
                                               

An example of Power Boost and Average Output Power

Power Boost    Peak Power   Power Boost               Duty Cycle     Non-Peak  Non-Peak Power       Total Time
                     (WP)    Duration (TP)                          Power (WN)    Duration (TN)            (T)
150%                                                 10%
150%          180           5 sec                    35%           113W         45 sec           50 sec
120%          180           5 sec                    20%           88W          9.3 sec          14.3 sec
120%          144           10 sec                   35%           114W         40 sec           50 sec
              144           10 sec                                 107W         18.5 sec         28.5 sec

It is not recommended to prolong the duration of Power Boost to be longer than the specified duty cycle calculation, this may cause
damage to the PSU.

11  All parameters are specified at 25C ambient unless otherwise indicated.
    www.DeltaPSU.com (May 2014, Rev. 02)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 120W 3 Phase / DRP024V120W3B

Overload & Overcurrent Protections                                    Overvoltage Protection

The power supply's Overload (OLP) and Overcurrent (OCP)               The power supply's overvoltage circuit will be activated when its
Protections will be activated when output current exceeds 150%        internal feedback circuit fails. The output voltage shall not exceed
of IO (Max load). In such occurrence, the VO will start to droop and  its specifications defined on Page 3 under "Protections".
once the power supply has reached its maximum power limit, the
protection is activated and the power supply will go into "Hiccup
mode" (Auto-Recovery). The power supply will recover once the
fault condition of the OLP and OCP is removed and IO is back
within the specifications.

It is not recommended to prolong the duration of IO when it is        Over Temperature Protection
<150% but >100%, since it may cause damage to the PSU.
                                                                      As mentioned above, the power supply also has Over
Short Circuit Protection                                              Temperature Protection (OTP). In the event of a higher operating
                                                                      temperature at 100% load, the power supply will run into OTP
The power supply's output OLP/OCP function also provides              when the operating temperature is beyond what is recommended
protection against short circuits. When a short circuit is applied,   in the de-rating graph. When activated, the output voltage will go
the output current will operate in "Hiccup mode", as shown in the     into bouncing mode until the temperature drops to its normal
illustration in the OLP/OCP section on this page. The power           operating temperature as recommended in the de-rating graph.
supply will return to normal operation after the short circuit is
removed.

12  All parameters are specified at 25C ambient unless otherwise indicated.
    www.DeltaPSU.com (May 2014, Rev. 02)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 120W 3 Phase / DRP024V120W3B

Operating Mode                                                                 Redundancy Operation
Fig. 3 Redundancy / Parallel Operation Connection Diagram                     In order to ensure proper redundancy
                                                                              operation for the power supply unit
                                                                              (PSU), ensure that the output voltage
                                                                              difference between the two units is kept
                                                                              at 0.45~0.50V for 24V supplies. Follow
                                                                              simple steps given below to verify:

                                                                              Step 1.
                                                                              Measure output voltage of PSU 1 and
                                                                              PSU 2. If PSU 1 is the master unit, then
                                                                              VO of PSU 1 must be higher than PSU 2.

                                                                              In order to set the output voltage, connect
                                                                              the power supply to 50% load and set the
                                                                              PSU 1 and PSU 2 output voltage.

                                                                              Step 2.
                                                                              Connect the right DRR module, 20A as
                                                                              per the system requirement to the power
                                                                              supply units PSU 1 and PSU 2 at Vin 1 &
                                                                              Vin 2 respectively.

                                                                              Step 3.
                                                                              Connect the system load from Vout.
                                                                              Please note that output voltage Vout from
                                                                              DRR module will be = VO (output voltage
                                                                              of power supply) Vdrop* (in DRR
                                                                              module).

Parallel Operation
These DRR modules can also be used for Parallel function in order to increase the output power by N+1 (e.g. 2.5A + 2.5A = 5A or 2.5A
+ 2.5A + 2.5A = 7.5A) or current sharing, and thus increasing the power supply and system reliability. Though the DRP024V120W3B
is not designed for current sharing, a good current sharing between two power supplies can be achieved by following simple steps as
below (Refer to Fig. 3 for the Connection Diagram).

Step 1.                                                         Step 3.
Set output load condition for both supplies at 50% and measure  Connect PSU 1 and PSU 2 with the DRR-20A module and
the output voltages.                                            measure at Vin 1 & Vin 2 to verify the voltage difference. Ensure
                                                                the voltages are within 25mV.
Step 2.
Adjust output voltages to the same level or within 25mV        Step 4.
difference.                                                     Output voltage from DRR module Vout will be = VO (output
                                                                voltage of power supply) Vdrop* (in DRR module).

*Vdrop will vary from 0.60V to 0.90V (Typical 0.65V) depending on the load current and surrounding air temperature.

13  All parameters are specified at 25C ambient unless otherwise indicated.
    www.DeltaPSU.com (May 2014, Rev. 02)
TECHNICAL DATASHEET

CliQ II DIN Rail Power Supply
24V 120W 3 Phase / DRP024V120W3B

Others
Delta RoHS Compliant

                               Restriction of the usage of hazardous substances
                               The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead,
                               mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and
                               electronic equipment. RoHS is the abbreviation for "Restriction of the use of certain hazardous substances in
                               electrical and electronic equipment".
                               This product conforms to this standard.

Conformal Coating
                               The Protective Coating Technology
                               Delta Electronics Group has designed the perfect dipping technique which penetrates everywhere including
                               under device, and prevents leakage. The conformal coating dipping can be applied to PCBAs or circuit board.
                               The coating preserves the performance of precision electronic primarily by preventing ionizable contaminants
                               such as salt from reaching circuit nodes, where the material slumps around sharp edges. This can be a problem
                               especially in highly conversing atmosphere.

14  All parameters are specified at 25C ambient unless otherwise indicated.
    www.DeltaPSU.com (May 2014, Rev. 02)
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Delta:

  DRP024V120W3BN
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company

小广播

DRP024V120W3BN器件购买:

数量 单价(人民币) mouser购买
1 ¥506.24 购买
5 ¥490.94 购买
10 ¥475.57 购买
25 ¥460.28 购买
50 ¥444.91 购买
100 ¥429.61 购买
250 ¥421.90 购买

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved