meter dpm lcd 3.5digit 2V IN

参数
Datasheets:
DPM500:
Product Photos:
DPM500 Series:
Standard Package : 1
Category: Industrial Controls, Meters
Family: Panel Meters
Series: Legacy
Type: Voltage (Voltmeter)
Measuring Range: 0 ~ 2VDC
Display Type: LCD - Black Characters
Number Of Characters Per Row: 3.5
Display Characters - Height: 0.492" (12.50mm)
Output Type: Reference
Voltage - Supply: 9VDC
Panel Cutout Dimensions: Rectangular - 57.00mm x 27.00mm
Mounting Type: Panel Mount - Bezel
Termination Style: PC Pin
Ingress Protection: -
Features: -
Operating Temperature: 0°C ~ 50°C
Weight: -
Other Names: 227-1010

DPM500-2器件文档内容

DPM 500                                                                                                                                                                                  3 Digit LCD Module

The DPM 500 uses advanced components and construction techniques to provide a uniquely compact unit. The meter is in a 40 pin
DIL integrated circuit format that can be plugged directly into a DIL socket or panel mounted using the snap in bezel. For single rail use,
the DPM 500S-BL features a built in negative rail generator, enabling the meter to measure a signal referenced to its own power supply
0V.

     12.5mm (0.5") Digit Height

Programmable Decimal Points                                                                                                                            -+                                    CF
Auto-zero                                                                                                                                                                                    A
Auto-polarity
200mV d.c. Full Scale Reading (F.S.R.)                                                                                                                                                       mV
                                                                                                                                                                                             k
                                                                                                                                                                                            MHz

Backlit Single Rail Version (DPM 500S-BL)

Annunciators

SCALING                                                                                                                Standard Meter                                                                    Stock Number
                                                                                                                       Backlit Single Rail Version                                                          DPM 500
Two resistors Ra and Rb may be fitted in order to alter the                                                                                                                                                DPM 500S-BL
full scale reading (F.S.R.) of the meter - see table.
Meter will need re-calibration.                                                                                        Specification                                   Min.          Typ.          Max.            Unit
                                                                                                                                                                                     0.05           0.1        % (1 count)
                                                                                                                       Accuracy (overall error)*                         0                          1
                                                                                                                                                                        7.5            3                           count
                                                                                                                       Linearity                                        3.5                          50         sample/sec
                                                                                                                                                                                     100
                                                                                                                       Sample rate                                                     9            14                C
                                                                                                                                                                                       5            6.5           ppm/C
Required F.S.R.                        Ra           Rb                                                                 Operating temperature range
2V                                    910k         100k                                                                                                                              150                              V
20V                 Note               1M          10k                                                                 Temperature stability                                         250
200V                Note               1M           1k
2kV                 Note               1M          100R                                                                Supply         DPM 500                                         30
200A               Note               0R           1k                                                                                                                                 1
2mA                                    0R          100R                                                                voltage        DPM 500S-BL
20mA                                   0R          10R
200mA                                  0R           1R                                                                 Supply current DPM 500                                                                  A

                                                                                                                       (not inc. backlighting) DPM 500S-BL

                                                                                                                       Backlight      Voltage                                                      5              V

                                                                                                                       (DPM 500S-BL) Current                                                       60          mA

                                                                                                                       Input leakage current (Vin = 0V)                                            10          pA

NOTE                                                                                                                    * To ensure maximum accuracy, re-calibrate periodically.
Ensure link 10 is cut if fitting Ra.
                                                                                                                       CONNECTOR SOURCING GUIDE

SAFETY                                                                                                                 METHOD                                          40 Pin DIL IC Socket

To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module's pins must not exceed 60Vdc. If voltages to the

measuring inputs do exceed 60Vdc, then fit scaling resistors externally to the module. The user must ensure that the incorporation of the

DPM into the user's equipment conforms to the relevant sections of BS EN 61010 (Safety Requirements for Electrical Equipment for

Measuring, Control and Laboratory Use).

DIMENSIONS All dimensions in mm (inches)

                             60.0 (2.36)                                                                1.1 8.2
                                                                                                     (0.04) (0.32)

                                                                                                                                      45.0 (1.77)                          a. DPM 500              6.7 (0.26)

                                                                                                                                                                             DPM 500S-BL 12.1 (0.48)

30.0 (1.18)                                                                                                                                                                b. 4.80 (0.19)
                                                                                           16.0 (0.63)
                                                                                                                                                                           Panel cut-out = 57 x 27 (2.24 x 1.06)

                                                                                                                                      Display in TEST mode

             5.0             52 (2.05)                                                                                 a 4.0 (0.16)
            (0.19)

               1          7           12           20                                                                                                                        9       11

8.5 (0.33)     V+                                                                                    b 15.2 (0.60)                            1                 7      12                20        DPM 500S-BL ONLY
                   V                                                                                      24.8 (0.98)                           13 12               5                              ON-BOARD LINKS
                       m                                                                                                                           10                                    8
                            A                                                                                                                     Rb   3                                           OPTIONAL SCALING
                                F                                                                                                                           2                                     RESISTORS
                                    C
                                                                                                                                                         14
                                                                M                                                                                              Ra
                                                                  K
                                                                            ~

                                                          -

                                                                                  XB3
                                                                                   :

                                                                                           E3
                                                                                            AB
                                                                                                POL

            -                                                                                                                         -                                          15

            +                                                                                                                         +                                      14

               40                                  21

               V+                                                                                                                             40           7                             21
                  
                       Hz

                            TEST
                               REF
                                 HI
                                    REF
                                      LO

                                         REF+
                                               REF-
                                                   COM
                                                      IN HI
                                                          IN LO

                                                               BG
                                                                   -5V
                                                                       XDP

                                                                           V-
                                                                                DP1
                                                                                       DP2
                                                                                            DP3
                                                                                             XG3

                                                                                                 BP

            1.87          0.5               2.54                                                                                                           REAR VIEW

            (0.07)        (0.02)            (0.1)

PANEL FITTING

Fit the bezel to the front of the panel and locate the meter into the bezel from behind. Alternatively the meter and bezel may be assembled before

fitting to the front of the panel but care must be taken not to use excessive force. Finally fit the window into the front of the bezel.
                                        Martel Electronics, Corp. P.O. Box 770 Londonderry, NH 03053
                                        Toll Free: (800) 821-0023 Phone: (603) 434-1433 Fax: (603) 434-1653

PIN FUNCTIONS

1, 40. V+          Positive power supply.

2 -7, 12-14, 17, 38, 39 See SPECIAL NOTE: ANNUNCIATORS.

15. -              Input for the polarity annunciator. Internally linked to POL (pin 20). If this is to be externally controlled, cut link 11.

16, 18, 19, 22 XB3, E3, AB, XG3. Outputs for use in auto-ranging applications.

20. POL            Drive for "-" annunciator. Internally connected by link 11.

21. BP             LCD backplane drive waveform.

23. DP3            1.999

24. DP2            19.99 See SPECIAL NOTE: ANNUNCIATORS.

25. DP1            199.9

26. V-             Negative power supply. Note that if the DPM 500S-BL is being used, the voltage between V+ and V- must not exceed 6.5V.

27. XDP            Connect to required annunciators/DPs (see note).

28. -5V            Output from negative rail generator circuit. This output is an inversion of V+ (DPM 500S BL ONLY).

29. BG             Input for bandgap reference. (1.22V nom).

30. IN LO Negative measuring input. Analogue inputs must be no closer than 1V to either the positive or negative supply. The negative

31. IN HI          Positive measuring input. supply of the DPM 500S-BL is generated internally and mirrors the positive supply voltage.

32. COM            The ground for the analogue section of the A/D converter, held actively at 2.8V (nom) below V+. COM must not be allowed to sink

                   excessive current (> 100A) by connecting it directly to a higher voltage.

33. REF-           Negative output from internal reference.

34. REF+ Positive output from internal reference.

35. REF LO Negative input for reference voltage.

36. REF HI Positive input for reference voltage.

37. TEST           Connecting this pin to V+ turns on the segments as illustrated. It should not be operated for more than a few seconds as the DC

                   voltage applied to the LCD may "burn" the display. This pin is nominally at 5V below V+ and is the ground for the digital section

                   of the meter, it can be used as a negative supply to power external logic up to a maximum of 1mA.

40. V+/CLK Normally tied to V+ via Link 12 but can be used to over ride the internal oscillator and control the sample rate by cutting Link 12 and

                   making Link 13.

LED BACKLIT VERSIONS: Apply 5V DC to the backlight tab on the side of the meter. Typical current is 30mA. For higher voltages, fit a resistor in series.
E.g. For 9V use 150R. Maximum current = 60mA.

SPECIAL NOTE: ANNUNCIATORS: The DPM annunciators (DPs, C, etc.) can be displayed by connecting them to XDP. However as these
annunciators are normally `floating', under certain conditions they may appear when not wanted. To suppress unwanted annunciators, link them to
the backplane (BP). If the annunciators are being switched, connect them via a 1M resistor to the BP (pin 21). The annunciators will then operate
normally when connected to XDP. Ensure that an annunciator is not connected directly to the XDP and BP at the same time.

VARIOUS OPERATING MODES                                                                                             Normally
                                                                                                                    SHORTED
ON-BOARD LINKS: In order to quickly and easily change operating modes for                                           Cut to                          Normally
                                                                                                                    OPEN                            OPEN
different applications, the meter has several "on-board links". They are designed                                                                   Solder to
                                                                                                                                                    SHORT
to be easily opened(cut) or shorted (soldered).

Do not connect more than one meter to the same power supply if the meters cannot

use the same signal ground. Taking any input beyond the power supply rails will

damage the meter.                                                                                      V+

                                  1 V+                                                            1  14V max                                       V+
                                V+                                                             V+    7V min                                   1
                                                                                      31 IN HI                                              V+

                   + 31 IN HI                                                   +     30 IN LO                                + 31 IN HI
                   - 30 IN LO
         200mV                                               200mV                                                200mV          30
                                                                                                                                         IN LO
                                                                                -                                             -

                                                                        0V

                                        V-                           1V min               V-                                                       V-
                                           26                                                                                                        26 0V
                                               V-                                         26         V-
                                                                                                                              Links 1, 3 & 4 SHORTED.
                 Links 1, 2, 3 & 4 SHORTED.                          Links 1, 3 & 4 SHORTED.
                                                                                                                    Measuring a single ended input
       Measuring a floating voltage                           Split supply operation (DPM 500).                     referenced to supply (DPM 500S-BL).
       source of 200mV full scale.

                                  V+                                                             V+                    IIN                              V+
                                1                                                             1                                             1
                   31 IN HI V+                                                                                      6R2
                                                                                   +  31       V+                                   31        V+
                                                                                          IN HI                       IOUT                  HI
                                                                                                                                        IN
                                                                     V1 - 30 IN LO
             R                                                                                                                220K

                            30                                           + 36 REF HI                                                30 IN LO
                                                                     V2 - 35 REF LO                                                 32 COM
                                IN LO                                                                                         5K
                                                                                        V-
         R=  0.2                V-                                                         26                                               V-
             IFSR                                                                             V-

                                   26 V-                                                                                                    26
             Links 1, 2, 3, 4 SHORTED.                                                                                                          V-

                                                                                                                              Links 1, 3 & 4 SHORTED.

       Measuring current                                      Measuring the ratio of two voltages.                  Measuring 4-20mA to read 0-999
       (supply MUST be isolated).                             Reading = 1000 V1/V2                                  (supply must be isolated).
                                                              50mV< V2<200mV
                                                              V1<2V2.

Specifications liable to change without prior warning         DPM 500                     Issue 4        July/1999  M.C.                Applies to DPM 500/7
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved