电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

DF104S

器件型号:DF104S
器件类别:半导体    分立半导体   
厂商名称:Thermtrol Corporation
厂商官网:http://www.thermtrol.com/
下载文档

器件描述

1.5 A, 200 V, SILICON, BRIDGE RECTIFIER DIODE

文档预览

DF104S器件文档内容

FEATURES                              The Thermal DF Series Thermal Cutoffs are single action devices that open when
                                 a preset temperature is reached. They do not reset. The active component of a ther-
Various temperature settings   mal cutoff is an electrically insulated thermal pellet. This pellet holds a spring loaded
Miniature size                 contact against a fixed contact under normal operating temperatures. (See Fig. 1)
Current rating: 15 Amp/125     When the preset temperature of the cutoff is reached, the pellet liquifies, the springs
                                 relax, and the spring loaded contact is moved away from the fixed contact, opening the
   Vac, 10 Amp/250 Vac           circuit. (See Fig. 2) The DF Series is the right choice for applications requiring an inex-
Economical                     pensive limit protector with 15A capability.
Accurate
Large inventory; same day      DF Series                                                  (Fig. 1) CLOSED
                                                                                            (Fig. 2) OPEN
   shipping
Various mounting options       A                    B                                  C

APPLICATIONS                                                                          D
                                               E
Thermal cutoffs are widely
used to prevent damage
from overheating in electrical
products
APPLIANCES - space

  heaters, irons, stoves,
  electric blankets, hair
  dryers, clothes dryers,
  cookers, toaster ovens,
  crock pots, mixers, toasters,
  microwave ovens, etc.
MOTORS - air conditioners,
  copiers, fans, washing
  machines, compressors,
  etc.
ELECTRONICS - TVs,
  stereos, tape recorders,
  video recorders, fluorescent
  lamps, transformers,
  computers, surge suppres-
  sors, telecommunication
  equipment, etc.

                                            Standard Dimensions (mm)

                                    A       B                        C                   D      E
                                 25.41                                                     4.00.1
                                            10.50.5                 351  10.05

                                 Custom lead lengths are available.

www.thermtrol.com                8914 Pleasantwood Ave., N.W. P.O. Box 2501 North Canton, OH 44720 (330) 497-4148 Fax (330) 497-4189

E-mail: sales@thermtrol.com
Precautions When Using                                                  Handling and Installation
                                                                        Instructions
Thermal Cutoffs
                                                                        When using thermal cutoffs, considerable caution should be exer-
      The following information describes the correct methods of        cised as follows:
using thermal cutoffs to insure proper and safe performance. To
achieve the full use and capacity of a thermal cutoff, it is necessary  A. Installation
for the customer to exercise proper storage and execute appropriate      Mount the thermal cutoff in a location where uniform radiation of
circuit design, proper installation, and adequate testing. Thermtrol    heat is sustained over the body of the unit.
Corporation does not assume responsibility for problems which occur      Keep the leads as long as possible to maximize the area of expo-
as a result of improper storage and installation, or inappropriate      sure to heat.
circuit design, evaluations or tests.                                    Place and connect the thermal cutoff in a manner so that no
Do not use thermal cutoffs for purposes other than for what they are  external mechanical force will be applied to the body and/or leads of
intended. Thermal cutoffs operate only when they sense an ambient       the thermal cutoff.
temperature greater than the factory pre-set temperature. They have      Allow adequate space for mounting the thermal cutoff.
no ability to function by current overload and are not current
limiting devices.                                                       B. Lead Bending
Do not use thermal cutoffs in equipment, appliances or devices         When bending a lead, bend at a location 5mm minimum from the
intended to be used in the aerospace industry, aviation, nuclear        body of the thermal cutoff.
power generation systems, life support systems, engine control          Take caution not to damage either the thermal cutoff body or the lead.
systems, or safety control systems for transportation. Thermal cutoffs   Keep the thermal cutoff body free from any push, pull or twist force.
are applicable for electrical household devices, appliances and
electronics. Other applications include: office automation equipment,   C. Soldering
audiovisual equipment, communication systems, measuring instru-         NOTE: The special sealant joining the lead wires to the case will
ments and specific transportation systems.                              soften during soldering. Care must be taken to not move the leads
Do not use thermal cutoffs in applications exceeding the listed       or body during the soldering process as the softened joints could
ratings in the specification chart.                                     shift and become disconnected. The sealant will resume its initial
Do not use thermal cutoffs in a liquid, in a corrosive atmosphere     strength after cooling.
such as sulfurous gas, or in a high humidity environment.                Minimize the conduction of excessive heat to the thermal cutoff
Customers shall choose the thermal cutoff appropriate for the         body when soldering.
application and determine the proper mounting position and/or            Maximum soldering time is shown in table above.
method. To judge whether the selected thermal cutoff and chosen          Solder 20 mm minimum from the thermal cutoff body.
position and method of mounting is suitable for the final application,   During soldering, both the thermal cutoff body and leads should be
we recommend that the customer fully test and evaluate the unit in an   free of any push, pull or twist force.
environment that duplicates the final application as closely as          After soldering, allow the thermal cutoff to cool for 30
possible. This includes mounting and securing the thermal cutoff        seconds minimum without moving it.
identically to the method that will be used in production.

        Electrical Ratings and Selected Agency Approvals

        Functioning              c                                      Maximum soldering time at solder bath
                                                                        temperature of 300C
Part Temperature (C) TH TM 15 Amp/125Vac 15 Amp/125Vac 10 Amp/250Vac

Number Tol: +0C/-4C (C) (C) 10 Amp/250Vac 10 Amp/250Vac

DF66S   66            42 130                                            Opening Temp. Max. Soldering Time

DF72S   72            50 110                                            Under 120 C  2 seconds

DF77S   77            55 130                                            Over 120 C   3 seconds

DF84S   84            60 114                                 

DF91S   91            67 121                                 

DF98S   98            76 130                                 

DF100S  100           78 135                                 

DF104S  104           80 150                                            Terminology:

DF110S  110           88 140                                            Functioning Temperature (TF)
                                                                        The temperature at which a thermal cutoff changes its state of
DF119S  119           95 170                                            conductivity to open a circuit with detection current of 10mA or less
                                                                        as the only load. The temperature tolerance for the UL and CSA
DF128S  128           106 155                                           standard is +0C / -10C.

DF139S  139           117 170                                           Holding Temperature (TH)
                                                                        The maximum temperature at which a thermal cutoff can be main-
DF141S  141           117 171                                           tained while conducting rated current for 168 hrs. without functioning.

DF144S  144           120 240                                           Maximum Temperature (TM)
                                                                        The maximum temperature at which mechanical and electrical prop-
DF152S  152           128 175                                           erties of a thermal cutoff can be maintained for 10 minutes without
                                                                        resuming conductivity after functioning.
DF170S  170           146 190                                
                                                                                                                                            12/13
DF184S  184           160 214                                

DF192S  192           167 210                                **

DF198S  198           170 244                                

DF216S  216           186 241                                **

DF228S  228           193 248                                **

DF240S  240           200 260                                **

UL/ CUL: E117626                  Approved  Pending
VDE: 115369, *116219
This datasheet has been downloaded from:
             www.EEworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播