器件描述

Digital Panel Meters 0-1.999mA input rge 3 1/2 Digit Grn LED

参数

产品属性属性值
产品种类:
Product Category:
Digital Panel Meters
制造商:
Manufacturer:
Murata
RoHS:YES
Equipment Type:DC Ammeters
Display Type:LED, 3.5 Digit, Green
工作电源电压:
Operating Supply Voltage:
8 VDC to 36 VDC
工作电源电流:
Operating Supply Current:
100 mA, 25 mA/DC
Input Current:2 mA
系列:
Series:
DCA-20PC
商标:
Brand:
Murata Power Solutions
Description/Function:Built in shunts
Dimensions:26.4 mm L x 35 mm W x 22 mm H
高度:
Height:
22 mm
长度:
Length:
26.4 mm
安装风格:
Mounting Style:
Panel Mount
封装:
Packaging:
Bulk
工厂包装数量:
Factory Pack Quantity:
12
宽度:
Width:
35 mm
单位重量:
Unit Weight:
0.608123 oz

DCA-20PC-2-DC4-GS-C器件文档内容

   www.murata-ps.com                                                                                                                                               DCA-20PC Series

                                                                                        LED Display, Subminiature DC Ammeters with Built-In Shunts

FEATURES                                                                       Murata Power Solutions’ new DCA-20PC Series are the first digital dc ammeters to include built-in

Built-in shunts for digitally measuring dc currents                          shunts for measuring dc currents up to 20A. Six ranges provide for precision measurement of

   from 200uA to 20A                                                           dc currents from 200uA to 20A. These ammeters are 100% self-contained; no calibration or

                                                                               user-supplied components are required—they even include terminal blocks for your external load

Functionally complete – no additional components                             circuit, a feature that enables simple 3-wire operation!

   required                                                                             Two shunt-configurations are offered: grounded-shunt (“low side”), 5-40V-powered models

Wide power supply inputs:                                                    for cost-sensitive applications, and 8-36V isolated-supply models for high side or floating shunt

   5 to 40Vdc for 5V/12/24V/28V applications                                   applications. A versatile power supply design accommodates all popular supply voltages from 5 to

   36-75V option for telecom supplies                                          75Vdc. Reverse-polarity-protected supply inputs ensure trouble free installation. And, because many

                                                                               dc ammeters are installed in battery backup applications, power consumption is typically below 1

8-36Vdc Isolated-supply models for high-side shunts                          Watt for 8-36V models, and below 75mW for 5-40V models. To further reduce overall power con-

20mV internal shunt minimizes power loss                                     sumption, the voltage dropped across its built-in series shunt is only 20mV!

                                                                                        DCA-20PC Series ammeters are housed in subminiature, 1.38˝ x 0.88˝ (35mm x 22mm),

Includes load connections for easy 3 or 4-wire                               rugged packages that feature a large, 0.37˝/9.4mm high, LED display. A built-in, high-contrast

   operation                                                                   color filter ensures that legibility is not compromised: the display can be easily read at distances

High resolution; Factory calibrated to ±0.1% accuracy                        up to 15 feet (5 meters). Available LED-display colors include brilliant blue, bright green, and

                                                                              standard red.

   Large, easy-to-read, LED display with 0.37” (9.4mm)                                  Built-in shunts, Precision electronics, miniature size, wide power supply inputs, low power

   high digits                                                                 consumption, and no-hassle 3-wire installation make DCA-20PC Series the ideal choice for all

Available with red, blue or green LED displays                               your 200uA to 20A ammeter-applications.

Small 1.38˝ x 0.88˝ x 1.0˝ package

                                                                          LED  DISPLAY

                                                                   –                                                       +5V

                                                      INPUT                                   A/D                                                    POWER

                                                AMPLIFIER          +                       CONVERTER                                             CONVERTER

                                                                                                                           –5V

                                                                BUILT-IN                   *                                                                            POWER

                                                                SHUNT                                                                                                   GROUND

                                                –               +                                   SIGNAL

                                                                                                    GROUND

                                                   1         2                                                                             1         22     3

                                                                                                                                              1  2

                                                                   TB1         *        Open on isolated-supply models                                             TB2

                                                                               **       Applies to isolated-supply models only

                                        –SHUNT                  +SHUNT                                                          LOAD  (+)        +V         –V **

                                        (–V)                                            –                               +

                                                                                           EXTERNAL

                                                                                              LOAD

                                                                                        –                               +

                                                                                           EXTERNAL

                                                                                           DC SUPPLY

                For full details go to

                www.murata-ps.com/rohs                                         Figure 1. Simplified Schematic

   www.murata-ps.com/support

                                                                                                                                                                                MPM_DCA-20PC.C01 Page 1 of 6
                                                                                                                           DCA-20PC Series

Performance/Functional Specifications                                                    LED  Display, Subminiature DC Ammeters with Built-In Shunts

Typical at TA = +25°C, unless otherwise noted.

Full Scale Load Current ➀       Min.                 Typ.   Max.                 Units          Physical/Environmental (continued)

DCA-20PC-1                                      –    –      199.9                µAdc           Humidity (non-condensing)                    0        –           85               %

DCA-20PC-2                                      –    –      1.999                mAdc           Case Material                                         Polycarbonate

DCA-20PC-3                                      –    –      19.99                mAdc           Dimensions                                      1.38"W x 0.88" x 1.0" nominal

DCA-20PC-4                                      –    –      199.9                mAdc           Weight                                                0.6 ounces (17 grams)

DCA-20PC-5                                      –    –      1.999                Adc

DCA-20PC-6                                      –    –      19.99                Adc            Ordering Information

Overcurrent Rating (<6 sec.) ➁                  1.5x rated full-scale load current              DCA-20PC - 1 - DC1 - R L - C

Internal Shunt Resistance                                                                                                                                Add -C for RoHS

DCA-20PC-1                                      –    –      100                  Ohms

DCA-20PC-2                                      –    –      10                   Ohms                                                                 LED Color:

                                                                                                                                                      BL = Low-Power Blue

DCA-20PC-3                                      –    –      1.0                  Ohm            Input Range:                                          BS = Super Blue

DCA-20PC-4                                      –    –      0.1                  Ohm                                                                  GS = Standard Green

                                                                                                Full-scale load current                               PGL = Low-Power Green

DCA-20PC-5                                      –    –      0.01                 Ohm            1 = 199.9µA                                           RL = Low-Power Red

DCA-20PC-6                                      –    –      0.001                Ohm            2 = 1.999mA              Power Supply:

                                                                                                3 = 19.99mA                DC1 = +5-40Vdc, non-isolated power

Shunt Input to Power Supply Isolation ➂                                                         4 = 199.9mA                          (available with -RL, -BL, or -PGL LEDs)

DCA-20PC-X-DC4 models only                      500  –      –                    Volts          5 = 1.999A                 DC4 = +8-36Vdc, isolated power

                                                                                                6=      19.99A                       (available with -RL, -BS, or -GS LEDs)

Performance

Sampling Rate                                        2.5 reading per second                     See www.murata-ps.com/dpm-availability for model-specific availability.

Accuracy                                             ±0.15%FS

Zero-Current Reading ➃          “–001”               “000”  “001”                Counts             Accessories:

                                                                                                        DMS-20-CP        Panel Cutout Punch

Temperature Drift (0 = +60°C)                   –    ±0.2   ±0.4                 Cnts/°C                A DMS-BZL4-C bezel assembly with sealing gasket is

Operating Supply Voltage (TB2 Terminals 1, 2 and 3) ➄                                                   supplied with each ammeter.

DCA-20PC-X-DC1-XX               +5.0                 –      +40                  Vdc         ➀  The noted full-scale values are the external load currents that the ammeter is

DCA-20PC-X-DC4-XX                               +8   –      +36                  Vdc            designed to measure. This current enters TB-1 (-SHUNT), passes through the am-

                                                                                                meter’s built-in shunt and exits via TB1-2 (+SHUNT). For all models, this same full-

Operating Supply Current (TB2 Terminals 1, 2 and 3) ➄                                           scale load current can also be routed, if the user so chooses, through TB2-1 and

DCA-20PC-X-DC1-XX (@ 5-40V)                     –    10     15                   mAdc           TB2-2 (connection to positive rail of power supply). See detailed wiring diagrams.

DCA-20PC-X-DC4-XX (@ 8V)                        –    100    150                  mAdc           Measuring positive and negative currents (bipolar operation): In applications

                                                                                                where both positive and negative currents must be measured, Murata Power Solu-

DCA-20PC-X-DC4-XX (@ 36V)                       –    25     40                   mAdc           tions recommends using ‘-DC4’ 8-36V isolated supply models. Negative current

TB1 and TB2 Terminal Blocks                                                                     flow is denoted by the illumination of the display’s negative (-) sign; the absence

                                                                                                of a negative sign implies positive current flow. Contact MPS if you have any ques-

Wire Size                                            12-20AWG, (solid)                          tions regarding bipolar operation of DCA-20PC ammeters.

                                                14-20AWG, (stranded) copper wire             ➁  For all models, the application of 1.5 times the rated full-scale load current is

Insulation Strip Length                              0.250 inches                               permissible as long as this overcurrent condition does not exceed 6 seconds and

Screw Tightening Torque                              4.4 pound/inches (0.5Nm)                   occurs no more than once in a 60 second interval (10% duty cycle).

Rated Current                                   20A with 12AWG solid copper wire;            ➂  Breakdown (isolation) voltage applies only to ‘-DC4’ isolated-power models. Break-

                                                15A with 14AWG solid or stranded                down voltage is tested with TB1-1 tied to TB1-2 (-SHUNT shorted to +SHUNT),

                                                     copper wire                                and TB2-1, TB2-2, and TB2-3 all tied together (+V shorted to -V). 500Vdc is then

                                                                                                applied between the two shorted terminal-block pairs; the maximum permissible

Display                                                                                         leakage current is 5uA.

Display Type and Size           3½ digit, 0.37"/9.4mm high red, blue or                      ➃  Zero reading is measured with TB1-1 (-SHUNT) shorted to TB1-2 (+SHUNT).

                                                     green LED                               ➄  The Operating power supply voltage is applied to TB2-1-2 (+V) and TB2-3 (-V)

Overrange Indication                                 "–1_ _ _" for negative Vin                 on ‘-DC4’ models, and to TB1-1 (-SHUNT) and TB2-2 (+V) on ‘-DC1’ models. On

                                                     "1_ _ _" for positive Vin                  all models, TB2-1 and TB2-2 are internally tied together (+V). Operating supply

Display Reading/Decimal Point                        Model dependent                            current is the current which powers the meter’s analog and digital circuits; it is

                                                                                                measured with zero load-current passing through the ammeter’s built-in shunt

Physical/Environmental                                                                          (i.e., with the display reading “000” and one decimal point enabled).

Operating Temperature                           0    –      +60                     °C          On 5-40Vdc powered (‘-DC1’), grounded-shunt models, the ammeter’s operating

Storage Temperature                             –20  –      +75                     °C          supply current enters TB1-1 (-Shunt) but is not included in the displayed reading

                                                                                                (i.e., it does not pass through the built-in shunt).

www.murata-ps.com/support

                                                                                                                                                      MPM_DCA-20PC.C01 Page 2 of 6
                                                                                                                                             DCA-20PC Series

                                                                                   LED Display, Subminiature DC Ammeters with Built-In Shunts

TECHNICAL NOTES

To ensure safe and reliable operation, DCA-20PC dc ammeters                                                               DCA-20PC ammeters’ power supply and shunt terminals are not

must be installed and serviced by qualified technical personnel.                                                           internally fused. Therefore, the supply wires connected to both the

DC ammeter applications can expose a user to potentially lethal                                                           meter and the load must be fused according to the maximum current

currents and voltages. Power and load connections must be made                                                            rating (or lower) of the wire gauge used, in accordance with applicable

with all associated power sources de-energized. Contact Murata                                                            regulatory codes.

Power Solutions if you have any questions regarding installation                                                          Wiring Insulation should be stripped to within +/-10% of the stated

or operation of any of our digital instruments.                                                                           dimensions. All wires must be inserted into the terminal block openings

1. Calibration: DCA-20PC ammeters are factory calibrated using a high-                                                    such that the screw terminal does not pinch any insulation. After final

precision current source. Under normal indoor operating conditions,                                                       assembly, inspect all terminal block connections for shorts between

periodic recalibration is not necessary. The calibration potentiometer,                                                   adjacent conductors; this step is particularly important when using

located on the back of the ammeter, is a ¾ turn type; do not force its                                                    stranded wire.

adjustment screw past the two end stops. If recalibration is necessary,                                                   3. Terminal Block Torque Ratings and Wire Size: It is important to

it must be performed by qualified personnel. Calibration is performed                                                      tighten all TB1 and TB2 screw-terminals to their torque specification

by applying a precision current source to TB1’s -SHUNT and +SHUNT                                                         of 4.4 pound-inches (0.5Nm). Proper tightening will minimize thermal/

terminals. For best results, use a load current that is approximately                                                     electrical losses and ensure reliable operation. Under severe operation

95% of the ammeter’s full-scale rating.                                                                                   conditions (for example, vibration, high continuous load currents, and

The calibration current source and power supply inputs must be con-                                                       wide variations in ambient temperature), 25% over-tightening is permis-

nected per the appropriate model-specific wiring diagram shown later                                                       sible. Applications subject to vibration should use stranded wire.

in this data sheet. Using an insulated slotted tool, adjust the calibra-                                                  Proper terminal block torque is extremely important on all 20A models

tion potentiometer until the display is within ±1 count of the desired                                                    (DCA-20PC-6 part numbers). Loose connections can overheat, thereby

reading. Please note, the potentiometer provides an adjustment range                                                      posing a potential fire hazard to the terminal blocks, the load and

of approximately ±1%. Contact Murata Power Solutions if additional                                                        supply wiring, the ammeters themselves, and nearby equipment. 20A

information is required regarding calibration or setup of DCA-20PC                                                        models must use either 14AWG stranded or 12 AWG solid copper

ammeters.                                                                                                                 wires only. However, in some applications, regulations can limit the

2. Wiring and Fusing: Power supply (TB2) and input (TB1) wiring must be                                                   continuous current flowing in 14AWG solid or stranded copper wire to

rated for the electrical and environmental conditions under which the                                                     15A maximum.

ammeters will be operated. They must also comply with any regula-                                                  4. High-Side versus Low-Side Shunts: Incorrect shunt connections

tory or application-mandated requirements pertaining to the user’s                                                        are one of the most common problems encountered when applying

installation. Connections to DCA-20PC ammeters must be made with                                                          digital dc-ammeters. Incorrect shunt connections can cause permanent

all power sources de-energized. Refer to the Functional Specifications                                                     damage to the ammeter and its associated equipment.

section for detailed wire type and wire gauge information.

                    DCA-20PC-X-DC1-XX                                                      DCA-20PC-X-DC1-XX                                                     DCA-20PC-X-DC1-XX

                                                     1                                                                    1                                                                      1

                                                        J3 MUST BE                                                           J3 MUST BE                                                             REMOVE J3

                                                        INSTALLED                                                            INSTALLED                                                              FOR 36-75Vdc

                                          J3            (FACTORY                                               J3            (FACTORY                                                               SUPPLIES

                    CAL                                 SETTING                            CAL              1                SETTING                             CAL                    J3

                                       1                                                                                     FOR 5-40Vdc                                             1

                                       2                FOR 5-40Vdc                                         2                                                                        2

                                                        SUPPLIES)                                                            SUPPLIES)

         1       2                  1         2                                 1       2                1         2                         SHUNT    1       2                   1       2

SHUNT       TB1                        TB2                             SHUNT       TB1                      TB2                                          TB1                         TB2

MUST BE                                                 TB2-1 & TB2-2  MUST BE                                               TB2-1 & TB2-2   MUST BE                                                TB2-1 & TB2-2

IN LOW                                                  INTERNALLY     IN LOW                                                INTERNALLY      IN LOW                                                 INTERNALLY

SIDE                                                    SHORTED        SIDE                                                  SHORTED         SIDE                                                   SHORTED

–SHUNT              +SHUNT      +V               +V                    –SHUNT              +SHUNT                     +V                     –SHUNT              +SHUNT       +V             +V

(–V)                                                                   (–V)                                                                  (–V)

                    –  LOAD     +                                                          –  LOAD  +                                                            –            +

                                                                                                                                                                    LOAD

                    LOAD CURRENT                                                   LOAD CURRENT                                                                  LOAD CURRENT

                                                                                   –    DC SUPPLY #2     +

                 –  DC SUPPLY       +                                                   (For Load Only)                                                       –  DC SUPPLY        +

                       5-40Vdc                                                                                                                                      36-75Vdc

                                                                                   –    DC SUPPLY #1     +

                                                                                           5-40Vdc                                           Figure 3. Low-Side Shunt Connections for "-DC1"

Figure 2A. Low-Side Shunt Connections for "-DC1"                       Figure 2B. Low-Side Shunt Connections for "-DC1"                      Models Modified for 36-75Vdc Non-Isolated Power

         5-40Vdc Non-Isolated Supply Models                                     Models using Two Power Supplies                                          (See Technical Note 6)

www.murata-ps.com/support

                                                                                                                                                                    MPM_DCA-20PC.C01 Page 3 of 6
                                                                                                                              DCA-20PC Series

                                                                            LED     Display,  Subminiature DC Ammeters with Built-In Shunts

TECHNICAL NOTES

Low-side shunts: Applications that employ a single power supply to                            7.  Decimal Points: DCA-20PC ammeters’ decimal points are factory con-

power both the load and the ammeter, and the external shunt is located                            figured for the respective full-scale input range. However, the decimal

in the negative side of the supply (commonly referred to as “low side” or                         points serve as placeholders only, they have no affect on the ammeter’s

“grounded shunt”) should use ‘-DC1’ non-isolated power DCA-20PC Series                            displayed accuracy or resolution.

ammeters. Figures 2 and 3 depict typical low-side shunt connections.

High-side shunts: ‘-DC4’ 8-36Vdc isolated-power models must be                                                             DCA-20PC-X-DC4-XX

used in all applications that employ a single power supply to power                                                                                          1

both the load and the ammeter and the shunt is located in the high side

(positive terminal) of the power supply. Figures 4 and 5 depict typical                                                    CAL

high-side shunt connections. As shown in Figure 5, ‘-DC4’ isolated-

power models can also be used in applications where one supply

powers the ammeter and a second supply powers the load, but the two

supply-grounds cannot be tied together. ‘-DC4’ models include a built-in                          SHUNT IS IN   1                          1

                                                                                                  HIGH SIDE        TB1  2                     TB2  2      3

dc/dc converter to provide a minimum 500Vdc isolation between the                                                                                                TB2-1 AND TB2-2

shunt (TB1) and power supply (TB2) inputs.                                                                                                                       ARE INTERNALLY

                                                                                                                                                                 SHORTED

5. Replacing Analog Panel Meters: DCA-20PC ammeters can be used

as replacements for analog panel meters if a suitable dc voltage                                     –SHUNT                +SHUNT             +V             –V

is available for powering the ammeter. In retrofit applications, it is

important to determine the shunt’s electrical configuration (i.e., high or                         +                                           +              –

low side). If any doubt exists as to the shunt’s location, use only ‘-DC4’

isolated-supply models. All rewiring must be performed with the load                              LOAD                                        DC SUPPLY #1

and power supply de-energized.                                                                    –                                                8-36Vdc

6. Operation With 36 to 75Vdc Power: As shipped, all ‘-DC1’ models’                                                    LOAD

                                                                                                                   CURRENT

rated operating supply range is +5 to +40Vdc. However, ‘-DC1’

models can be user configured for 36 to 75Vdc operation by removing                                           –  DC SUPPLY     +

(opening) jumper J3. Please note that this modification can only be                                                 #2

performed on ‘-DC1’ power models. Also, all ‘-DC1’ models – including                             Figure 5. Using "-DC4" Isolated-Power Models to Maintain       Isolation

those that have been modified for 36-75Vdc operation – can only be                                                  Between Two Power Supplies

connected in low-side, grounded-shunt applications. See Figure 3 for

                                                                                                                           DCA-20PC-X-DC4-XX

                            DCA-20PC-X-DC4-XX

                                                                                                                                                             1

                                                               1

                                                                                                                           CAL

                                CAL

SHUNT IS IN                                                                                                     1       2                  1       2      3

HIGH SIDE        1       2                   1       2      3                                     SHUNT IS IN      TB1                        TB2

                    TB1                         TB2                                               LOW SIDE                                                       TB2-1 AND TB2-2

                                                                   TB2-1 AND TB2-2                                                                               ARE INTERNALLY

                                                                   ARE INTERNALLY                                                                                SHORTED

                                                                   SHORTED

                                                                                                     –SHUNT                +SHUNT      +V             +V     –V

–SHUNT                      +SHUNT       +V             +V     –V

                                                                                                                           –  LOAD     +

             +

LOAD                                                                                                                       LOAD CURRENT

             –              LOAD CURRENT

                                                                                                                        –  DC SUPPLY       +

                         –  DC SUPPLY        +                                                                                8-36Vdc

                                8-36Vdc

Figure 4. High-Side Shunt Connections for                      "-DC4"                                Figure        6. Using "-DC4" Isolated-Power Models

                 8-36Vdc Isolated-Power Models                                                                     in Low-Side Shunt Applications

www.murata-ps.com/support

                                                                                                                                              MPM_DCA-20PC.C01            Page    4  of  6
                                                                                                                                      DCA-20PC Series

                                                                              LED Display, Subminiature DC Ammeters with Built-In Shunts

TECHNICAL NOTES

    If desired, an alternative decimal point by can be enable by opening the                                illumination of the display’s negative (-) sign; the absence of a negative

    factory closed solder gap and then closing one of the other two solder                                  sign implies positive current flow. Contact Murata Power Solutions

    gaps. The closing of SG1, SG2, or SG3 selects DP1 (“1.XXX”), DP2                                        if you have any questions regarding bipolar operation of DCA-20PC

    (“1X.XX”), or DP3 (“1XX.X”), respectively.                                                              ammeters. detailed wiring information. Any reconfiguration of J3 must

8.  Noisy Power Supplies: Some power supplies contain high-frequency                                        be made prior to connecting the power supply and load to the ammeter.

    switching devices that may conduct and/or radiate significant noise                                                                   DCA-20PC-X-DC1-XX

    onto the low-level signal developed across the internal shunt. Even                                                                                                1

    though DCA-20PC ammeters incorporate built-in input filtering, some

    portion of this noise may be amplified and subsequently measured by                                                                   CAL                  J3

    its sensitive input circuitry. The amplified noise introduces errors that                                                                               1

                                                                                                                                                           2

    are particularly noticeable at zero load current (i.e., the ammeter may

    not display a relatively steady “000” reading).                                                            SHUNT

                                                                                                               MUST BE

    Connecting an external, unpolarized capacitor across TB1’s -SHUNT                                       IN LOW SIDE

    and +SHUNT inputs can help reduce noise-related display errors.                                                           1       2                 1  TB2  2

                                                                                                                                 TB1

    In certain situations, the use of twisted pair or shield wiring may be

    required. As a general rule, avoid using excessively long leads between

    the ammeter and the load.                                                                                  –SHUNT                    +SHUNT                    +V

9.  ‘Power ON’ LED: DCA-20PC ammeters include a rear-mounted ‘Power                                                     (–V)

    On’ LED. The bright illumination of this LED indicates that the meter’s

    internal power converter is operational. It does not signify that the                                                                –  LOAD     +

    ammeter and the external load are connected correctly.

10. Measuring positive and negative currents (bipolar operation):                                                                     LOAD CURRENT

    In applications where both positive and negative currents must be

    measured, Murata Power Solutions recommends using ‘-DC4’ 8-36V                                                                    –  DC SUPPLY      +

    isolated supply models. Negative current flow is denoted by the                                                                          5-40Vdc

                                                                                                                        Figure 7. 3-Wire Connections for "-DC1"

PANEL INSTALLATION                                                                                                               5-40Vdc Powered Models

    All connections and modifications must be made after the ammeter                  ammeter. See the Mechanical Specifications section for detailed panel

    is securely attached to the panel, with all load and supply voltages             cutout and ammeter dimensions.

    de-energized (off).                                                              Following the four-step sequence shown in Figure 8 below, being careful

    The installed wire-positions should be such that minimal forces are applied      not to apply excessive force or twisting motions, insert the ammeter into

    to TB1, TB2, and the ammeter itself. In high-vibration environments, the         the panel opening. When using the DMS-BZL4’s sealing gasket, make

    use of wiring strain-reliefs is recommended.                                     sure it is positioned between the ammeter’s flange and the panel’s front

    To insure a secure panel-mount installation, MPS recommends using                surface. Be sure to use and securely tighten all four screws supplied with

    the DMS-BZL4 (with sealing gasket) bezel assembly supplied with each             the bezel assembly.

    Step 1.                                          Step 2.                         Step 3.                                                  Step 4.

                               PANEL                                          PANEL                            PANEL                                               PANEL

    1                                                                                                       3                                     BEZEL

                                                     2

                                                                                     4

                                                                                                                                                 GASKET

                                                                                                                                                 (optional)

                                                                              Figure 8. Panel Installation

    www.murata-ps.com/support

                                                                                                                                                        MPM_DCA-20PC.C01  Page 5 of 6
                                                                                                                                      DCA-20PC Series

                                                                    LED Display, Subminiature DC Ammeters with Built-In Shunts

MECHANICAL SPECIFICATIONS

MECHANICAL DIMENSIONS: Inches (mm)                                                                               0.475

                                                                                                                 (12.1)    1.04

TOLERANCES:  2 PL DEC ±0.02 (±0.51)                                                                                        (26.4)

             3 PL DEC ±0.010 (±0.254)

                                                       0.040                   1.30                                 0.040                     0.80

                                                       (1.02)            (33.0)                                  (1.02)                       (20.3)

                                                                               1.38                                                           0.88

                                                                         (35.1)                                                               (22.4)

                                                                                                                                                      1.42

                                                                                                                                                      (36.1)

                                                            FRONT VIEW                          BACK VIEW                                  BACK VIEW

                                                            ALL MODELS            DCA-20PC-X-DC4 MODELS                          DCA-20PC-X-DC1 MODELS

                                                                                                                        1                                               1

                                                                                                                                                                 J3

                                                                                                   CAL                     SG3                CAL             1            SG3

                                                                                                                                                              2

                                                                                                                           SG2                                             SG2

                                                                                                                           SG1                                             SG1

                                                                                     1          2       1   TB2  2  3              1       2          1     TB2      2

                                                                                           TB1                                        TB1

                                                       DP1     DP2  DP3

                                                                                  –SHUNT                +V          –V          –SHUNT                +V

                                                                                     +SHUNT                 +V                        +SHUNT                     +V

BEZEL INSTALLATION AND RECOMMENDED                     DRILL AND         PANEL CUTOUT

                                                                                  0.093 (2.362) DIAMETER (4 REQUIRED)

             #2-56 INSERT              0.187                                      ONLY WHEN USING SUPPLIED BEZEL ASSEMBLY

             0.156 (3.96) DEEP         (4.75)                                                                                                                           0.116  (2.95)

FRONT VIEW                                                                                 INTERNAL CORNER RADII:

                                                                                                        0.032 (0.81) MAX.

             DMS-BZL4 BEZEL                    1.280                     1.07                                                                                              0.838

                                              (32.51)                    (27.18)                                                                                           (21.29)

                                                                                                            1.336 (33.93)                                        0.145 (3.68)

             1.826 (46.38)

                                                                                                            1.626 (41.30)

Murata Power Solutions, Inc.                                                                       This product is subject to the following operating requirements

11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.                                                 and the Life and Safety Critical Application Sales Policy:

ISO 9001 and 14001 REGISTERED                                                                      Refer to: http://www.murata-ps.com/requirements/

                                                                                  Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other

                                                                                  technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply

                                                                                  the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without

                                                                                  notice.                                                                                      © 2015 Murata Power Solutions, Inc.

www.murata-ps.com/support

                                                                                                                                                              MPM_DCA-20PC.C01 Page 6 of 6
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Murata:

DCA-20PC-3-DC1-RL       DCA-20PC-1-DC1-RL  DCA-20PC-4-DC1-RL    DCA-20PC-2-DC1-RL  DCA-20PC-4-DC4-RL

DCA-20PC-5-DC4-RL  DCA-20PC-5-DC1-RL       DCA-20PC-6-DC4-GS    DCA-20PC-2-DC4-GS  DCA-20PC-5-DC4-GS

DCA-20PC-1-DC4-GS  DCA-20PC-3-DC4-GS       DCA-20PC-4-DC4-GS    DCA-20PC-1-DC4-RL  DCA-20PC-2-DC4-RL

DCA-20PC-4-DC4-BS  DCA-20PC-2-DC4-BS       DCA-20PC-6-DC4-BS    DCA-20PC-3-DC4-BS  DCA-20PC-1-DC4-BS

DCA-20PC-5-DC4-BS  DCA-20PC-5-DC1 (RL)     DCA-20PC-6-DC1 (RL)  DCA-20PC-1-DC1-BL-C  DCA-20PC-1-DC1-

PGL-C  DCA-20PC-1-DC1-RL-C  DCA-20PC-1-DC4-BS-C  DCA-20PC-1-DC4-GS-C   DCA-20PC-1-DC4-RL-C  DCA-

20PC-2-DC1-BL-C  DCA-20PC-2-DC1-PGL-C      DCA-20PC-2-DC1-RL-C  DCA-20PC-2-DC4-BS-C  DCA-20PC-2-DC4-

GS-C   DCA-20PC-2-DC4-RL-C  DCA-20PC-3-DC1-BL-C  DCA-20PC-3-DC1-PGL-C  DCA-20PC-3-DC1-RL-C  DCA-

20PC-3-DC4-BS-C  DCA-20PC-3-DC4-GS-C       DCA-20PC-3-DC4-RL-C  DCA-20PC-4-DC1-BL-C  DCA-20PC-4-DC1-

PGL-C  DCA-20PC-4-DC1-RL-C  DCA-20PC-4-DC4-BS-C  DCA-20PC-4-DC4-GS-C   DCA-20PC-4-DC4-RL-C  DCA-

20PC-5-DC1-BL-C  DCA-20PC-5-DC1-PGL-C      DCA-20PC-5-DC1-RL-C  DCA-20PC-5-DC4-BS-C  DCA-20PC-5-DC4-

GS-C   DCA-20PC-5-DC4-RL-C  DCA-20PC-6-DC1-BL-C  DCA-20PC-6-DC1-PGL-C  DCA-20PC-6-DC1-RL-C  DCA-

20PC-6-DC4-BS-C  DCA-20PC-6-DC4-GS-C       DCA-20PC-6-DC4-RL-C  DCA-20PC-3-DC4-RL    DCA-20PC-6-DC1-RL

DCA-20PC-6-DC4-RL

小广播

DCA-20PC-2-DC4-GS-C器件购买:

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved