CUB4CL20

器件型号:CUB4CL20
器件类别:热门应用    测试测量   
厂商名称:Red Lion Controls, Inc.
厂商官网:http://www.redlion.net/
标准:  
下载文档

器件描述

loop W/red neg bklting

参数
Datasheets:
CUB4LP/CL:
Product Photos:
CUB4CL20:
3D Model:
CUB4CL.dwg:
Standard Package : 1
Category: Industrial Controls, Meters
Family: Panel Meters
Series: CUB4CL
Type: Process Meter
Measuring Range: 4 ~ 50mA
Display Type: LCD - Red Characters, Backlight
Number Of Characters Per Row: 3.5
Display Characters - Height: 0.600" (15.20mm)
Output Type: -
Voltage - Supply: Loop Power, 9 ~ 28VDC (Backlight)
Panel Cutout Dimensions: Rectangular - 68.00mm x 33.00mm
Mounting Type: Panel Mount
Termination Style: Screw Terminal
Ingress Protection: IP65 (Face)
Features: -
Operating Temperature: 0°C ~ 60°C
Weight: 0.206 lb (93.44g)
Dynamic Catalog: CUB4CL and CUB4LP Series
Other Names: RLC159

CUB4CL20器件文档内容

                                                                                                                           Bulletin No. CUB4LP-M
                                                                                                                           Drawing No. LP0318
                                                                                                                           Released 12/13

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

MODEL CUB4LP - LOOP POWERED PROCESS INDICATOR
MODEL CUB4CL - CURRENT LOOP INDICATOR

                                                                                               DUAL RANGE, 4 to 20 mA OR 10 to 50 mA

                                                                                               3-DIGIT, 0.6" (15.2 mm) HIGH DIGITS

                                                                                               POSITIVE IMAGE TRANSFLECTIVE LCD WITH RED BACKLIGHT
                                                                                                 OR POSITIVE IMAGE REFLECTIVE LCD (CUB4LP)

                                                                                               POSITIVE IMAGE TRANSFLECTIVE LCD WITH RED BACKLIGHT
                                                                                                 OR NEGATIVE IMAGE TRANSMISSIVE WITH RED OR YELLOW/
                                                                                                 GREEN BACKLIGHT (CUB4CL)

                                                                                               SPAN AND OFFSET CAPABILITY

                                                                                               NEGATIVE AND OVERRANGE INDICATION

                                                                                               SELECTABLE DECIMAL POINT POSITION

                                                                                               NEMA 4X/IP65 SEALED FRONT PANEL BEZEL

                                                                                               FITS DIN STANDARD CUT-OUT 2.68" (68 mm) X 1.30" (33 mm)

FOR USE IN HAZARDOUS LOCATIONS:
   Class I, Division 2, Groups A, B, C, and D
   Class II, Division 2, Groups F and G
   Class III, Division 2

DESCRIPTION                                                                                   SAFETY SUMMARY

   The CUB4LP and CUB4CL are additions to the CUB4 product line. The                             All safety related regulations, local codes and instructions that appear in the
CUB4LP uses a 4 to 20 mA or a 10 to 50 mA input signal as operating power.                    manual or on equipment must be observed to ensure personal safety and to
The input signal is also used to power the backlighting on the CUB4LP40 unit.                 prevent damage to either the instrument or equipment connected to it. If
The CUB4CL uses a 4 to 20 mA or a 10 to 50 mA input signal to power the unit.                 equipment is used in a manner not specified by the manufacturer, the protection
An external power supply is used to power the CUB4CL backlighting to provide                  provided by the equipment may be impaired.
a brighter, more consistent display and a lower compliance voltage.
                                                                                                            WARNING - EXPLOSION HAZARD - SUBSTITUTION
   The units have a 3-digit LCD display with 0.6" (15.2 mm) high digits and                                OF ANY COMPONENTS MAY IMPAIR SUITABILITY FOR
a DIP switch selectable decimal point. The CUB4LP display is available in                                   CLASS I, DIVISION 2 / CLASS II, DIVISION 2 / CLASS III, DIVISION 2
positive image reflective (dark digits, reflective background) or positive image
transflective (dark digits, illuminated background) with red backlighting. The                SPECIFICATIONS
CUB4CL display is available in positive image transflective (dark digits,
illuminated background) with red or yellow/green backlighting or negative                     1. DISPLAY: 3-digit (-1999 to 1999), 0.6" (15.2 mm) high digits.
image transmissive (illuminated digits, dark background) with red or yellow/                     The CUB4LP is available with a positive image reflective LCD or a red
green backlighting.                                                                              backlit positive image transflective LCD. The intensity of the backlighting
                                                                                                 will vary with the input signal.
   The ability to scale the display allows indication in any desired unit of                     The CUB4CL is available with a positive image transflective LCD with red
measurement such as temperature, pressure, humidity, fluid flow, etc. The unit                   or yellow/green backlighting or a negative image transmissive with red or
is calibrated at the factory with 0.0 displayed @ 4 mA input and 100.0 displayed                 yellow/green backlight.
@ 20 mA input.                                                                                   A minus sign is displayed when the indicator is adjusted for a negative offset.
                                                                                                 Overrange: Overrange is indicated by a "1" in the most significant digit and
   The units are contained in a lightweight, high impact plastic case with a clear                  the blanking of the three least significant digits.
viewing window. When properly installed, the sealed front panel meets NEMA
4X/IP65 specifications for wash-down and dusty environments.                                  2. EXTERNAL BACKLIGHT POWER: (CUB4CL only)
                                                                                                 9 - 28 VDC, @ 35 mA typ., 50 mA max. Power Supplies must be Class 2
                                                          CAUTION: Risk of Danger.               (NEC) or SELV rated. Above 26 VDC, derate the operating temperature to
                                                     Read complete instructions prior to         50C.
                                                  installation and operation of the unit.
                                                                                              3. DECIMAL POINTS: Three DIP switch selectable, decimal point positions
                                                                                                 allow the display to be read in tenths, hundredths or thousandths.

DIMENSIONS In inches (mm)           Note: Recommended minimum clearance (behind the panel) for
                                            mounting clip installation is 2.15" (54.6) H x 3.00" (76.2) W.

                                                 .13 (3.3)                                                 PANEL CUT-OUT

                                    1.54 (39.1)                                               1.29 (32.8)  2.68+-..000205  1.30  +.024
                                                                                                           (68+-..80 )           -.000
                                                                                                                           (33+-..60 )

                       2.95 (74.9)  .15 (3.8)    1.96 (49.8)

                                                                                           1
SPECIFICATIONS (Cont'd)                                                               14. CERTIFICATIONS AND COMPLIANCES:
                                                                                         CE Approved
4. MAXIMUM VOLTAGE DROP:                                                                    EN 61326-1 Immunity to Industrial Locations
   3.2 VDC for CUB4LP00                                                                     Emission CISPR 11 Class B
   4.0 VDC for CUB4LP40                                                                  Safety requirements for electrical equipment for measurement, control, and
   3.2 VDC for CUB4CL all models                                                            laboratory use:
                                                                                            EN 61010-1: General Requirements
5. EQUIVALENT RESISTANCE:                                                                RoHS Compliant
   CUB4LP00: 800  max. @ 4 mA; 160  max. @ 20 mA                                         UL Hazardous: File #E184589
             320  max. @ 10 mA; 65  max. @ 50 mA                                         Type 4X Indoor Enclosure rating (Face only)
   CUB4LP40: 1000  max. @ 4 mA; 200  max. @ 20 mA                                        IP65 Enclosure rating (Face only)
             400  max. @ 10 mA; 80  max. @ 50 mA                                         Refer to the EMC Installation Guidelines of this bulletin for additional
   CUB4CL (all models): 800  max. @ 4 mA; 160  max. @ 20 mA                                 information.
             320  max. @ 10 mA; 65  max. @ 50 mA
                                                                                      15. ENVIRONMENTAL CONDITIONS:
6. MAXIMUM ALLOWABLE INPUT CURRENT: 100 mA                                               Operating Temperature: 0 to 60C
7. SCALING RANGE:                                                                           (Derate backlight voltage to 26 VDC above 50C.)
                                                                                         Storage Temperature: -40 to 80C
   Span: Two potentiometers provide a coarse and fine span adjustment. Span              Operating and Storage Humidity: 85% max. (non-condensing) from 0C to
      range = 0 to 2000.                                                                    60C.
                                                                                         Vibration to IEC 68-2-6: Operational 5 to 500 Hz, 5g
   Offset: Two potentiometers provide a coarse and fine zero offset adjustment.          Shock to IEC 68-2-27: Operational 30 g
      Offset range = -1999 to 1999.                                                      Altitude: Up to 2000 meters

8. LINEARITY: (@ 23C, Less than 85% RH) (0.1% + 1 digit).                           16. WEIGHT: 3.3 oz. (93.5 g)
9. READING RATE: 2.5 per second, nominal.
10. RESPONSE TIME: 1.5 seconds to settle for a step change.
11. NORMAL MODE REJECTION: 60 dB 50/60 Hz
12. TEMPERATURE EFFECTS:

   Span Temperature Coefficient: 100 PPM/C
   Offset Temperature Coefficient: 0.2 digits/C
13. CONSTRUCTION: High impact plastic case with clear viewing window.
   (Panel gasket and mounting clips included.) This unit is rated for NEMA 4X/
   IP65 indoor use. Installation Category I, Pollution Degree 2

INSTALLATION                                                                       MOUNTING SCREW
                                                                                       NUT FASTENER
   When properly installed, the CUB4LP/CL meets
NEMA 4X/IP65 requirements for indoor use. The                                                          MOUNTING CLIP         EXISTING PANEL
units are intended to be mounted into a suitably rated                                                                         .05" to .20"
enclosed panel. A sponge rubber gasket, mounting
clip, two screws, and nut fasteners are provided to                                                                          (1.3 to 5.1mm)
install and seal the unit in the panel cutout.                                                                                     THICK

Installation Environment                                 LATCHING
                                                         FEATURE
   The unit should be installed in a location that does
not exceed the maximum operating temperature and
provides good air circulation. Placing the unit near
devices that generate excessive heat should be
avoided.

   The bezel should be cleaned only with a soft cloth
and neutral soap product. Do NOT use solvents.

   Continuous exposure to direct sunlight may
accelerate the aging process of the bezel.

   The following procedure assures proper installation:                                    GASKET      LATCHING
1. Cut the panel opening to the specified dimensions.                                 0.093" (2.4 mm)  FEATURE

   Remove burrs and clean the panel opening.                                                 THICK
2. Slide nut fastener into slot on mounting clip and then insert
                                                                                                                      BEZEL
   mounting screw through nut on both sides of mounting clip. The
   tip of mounting screw should not project through hole on clip.                     6. If the gasket is not adequately compressed and the mounting screws cannot
3. Slide the panel gasket over the rear of the unit to the back of the bezel.            be tightened any further, loosen the mounting screws and insure that the clip
   Install CUB4LP/CL unit through panel cutout.                                          is latched as closely as possible to the panel.
4. Slide mounting clip over rear of unit until the clip is against back of panel.
   The mounting clip and CUB4LP/CL housing have a latching feature to hold            7. Repeat Step #6 for tightening the mounting screws.
   the unit in place until tightened.

   Note: Hold the CUB4LP/CL front bezel in place when sliding the mounting
      clip into position.

5. Alternately tighten each mounting screw to ensure uniform gasket pressure.
   Visually inspect the gasket for proper seal. The gasket should be compressed
   to approximately 75 to 80% of its original thickness.
   (Recommended torque is 28 to 36 in-oz.)

                                                                                   2
EMC INSTALLATION GUIDELINES                                                           effective. The following EMI suppression devices (or equivalent) are

   Although Red Lion Controls Products are designed with a high degree of             recommended:
immunity to Electromagnetic Interference (EMI), proper installation and wiring
methods must be followed to ensure compatibility in each application. The type        Fair-Rite part number 0443167251 (RLC part number FCOR0000)
of the electrical noise, source or coupling method into a unit may be different
for various installations. Cable length, routing, and shield termination are very     Line Filters for input power cables:
important and can mean the difference between a successful or troublesome
installation. Listed are some EMI guidelines for a successful installation in an             Schaffner # FN2010-1/07 (Red Lion Controls # LFIL0000)
industrial environment.
1. A unit should be mounted in a metal enclosure, which is properly connected         6. To protect relay contacts that control inductive loads and to minimize radiated

   to protective earth.                                                               and conducted noise (EMI), some type of contact protection network is
2. Use shielded cables for all Signal and Control inputs. The shield connection
                                                                                      normally installed across the load, the contacts or both. The most effective
   should be made as short as possible. The connection point for the shield
   depends somewhat upon the application. Listed below are the recommended            location is across the load.
   methods of connecting the shield, in order of their effectiveness.
   a. Connect the shield to earth ground (protective earth) at one end where the      a. Using a snubber, which is a resistor-capacitor (RC) network or metal oxide

      unit is mounted.                                                                varistor (MOV) across an AC inductive load is very effective at reducing
   b. Connect the shield to earth ground at both ends of the cable, usually when
                                                                                      EMI and increasing relay contact life.
      the noise source frequency is over 1 MHz.
3. Never run Signal or Control cables in the same conduit or raceway with AC          b. If a DC inductive load (such as a DC relay coil) is controlled by a transistor

   power lines, conductors, feeding motors, solenoids, SCR controls, and              switch, care must be taken not to exceed the breakdown voltage of the
   heaters, etc. The cables should be run through metal conduit that is properly
   grounded. This is especially useful in applications where cable runs are long      transistor when the load is switched. One of the most effective ways is to
   and portable two-way radios are used in close proximity or if the installation
   is near a commercial radio transmitter. Also, Signal or Control cables within      place a diode across the inductive load. Most RLC products with solid state
   an enclosure should be routed as far away as possible from contactors, control
   relays, transformers, and other noisy components.                                  outputs have internal zener diode protection. However external diode
4. Long cable runs are more susceptible to EMI pickup than short cable runs.
5. In extremely high EMI environments, the use of external EMI suppression            protection at the load is always a good design practice to limit EMI.
   devices such as Ferrite Suppression Cores for signal and control cables is
                                                                                      Although the use of a snubber or varistor could be used.

                                                                                      RLC part numbers: Snubber: SNUB0000

                                                                                                        Varistor: ILS11500 or ILS23000

                                                                                      7. Care should be taken when connecting input and output devices to the

                                                                                      instrument. When a separate input and output common is provided, they

                                                                                      should not be mixed. Therefore a sensor common should NOT be connected

                                                                                      to an output common. This would cause EMI on the sensitive input common,

                                                                                      which could affect the instrument's operation.

                                                                                         Visit RLC's web site at http://www.redlion.net/Support/InstallationConsiderations.
                                                                                      html for more information on EMI guidelines, Safety and CE issues as they
                                                                                      relate to Red Lion Controls products.

WIRING CONNECTIONS                                                                                      OFFSET SPAN

   All conductors should meet voltage and current ratings for                         10-50
each terminal. Also cabling should conform to appropriate                                 0.0
standards of good installation, local codes and regulations. It is                            0.00
recommended that power supplied to the unit (AC or DC) be                                         0.000
protected by a fuse or circuit breaker.                                                                                      COARSE
                                                                                                                                    FINE
   The electrical connections are made via screw-clamp terminals                                                                            COARSE
located on the back of the unit. When wiring the unit, use the                                                                                      FINE
label to identify the wire position with the proper function. Strip
the wire, leaving approximately " of bare wire (stranded wires                       1234                                                                         4 SIG +
should be tinned with solder). Insert the wire into the screw-                                                                                                          (SENSOR)
clamp terminal and tighten the screw until the wire is clamped                        3 CUB4LP/CL       OFFSET SPAN
tightly. Each terminal can accept up to two #14 AWG wires.                                                                                                         2 VDC +
                                                                                      SIG.-      10-50                                                          4        (CL ONLY)
                                                                                                     0.0                                                  SIG.+
                                                                                             ON          0.00                                                      1 COM
                                                                                                             0.000                                              2        (CL ONLY)
                                                                                                                    COARSE                                    V+
                                                                                                                           FINE                            (CL)    3 SIG -
                                                                                                                                   COARSE                               (SENSOR)
                                                                                                                                           FINE

                                                                                      1 COM

                                                                                      (CL)       1 234

                                                                                                 RED LION CONTROLS                                        M1721C

                                                                                                 YORK, PA. MADE IN U.S.A.

CUB4LP/CL SIGNAL INPUT                                                                SPAN ADJUSTMENTS

   The current range is selected by setting DIP switch S1 to the OFF position            Span is defined as the numerical range that the display traverses, disregarding
for a 4 to 20 mA input or ON for a 10 to 50 mA input. Attach the signal wires         the decimal point, when the input signal is varied from minimum to maximum
to terminals 3 (SIG-) and 4 (SIG+) observing the correct polarity. The (SIG-)         (4 to 20 mA or 10 to 50 mA). For example; if a unit is to display 250 @ 4 mA
signal input circuit is not reverse polarity protected.                               and 1000 @ 20 mA, the span is 750 (the difference between 250 and 1000). Had
                                                                                      the minimum display been -250, the span would be 1250 (1000 - (-250) = 1250).
Backlight Power (CUB4CL only)                                                         The CUB4LP/CL can be set to operate over a wide span range by adjusting the
   Attach a 9 to 28 VDC supply to terminals 1 (COM) and 2 (V+) to power the           Coarse and Fine Span adjustment pots. The Coarse Span pot is used to get the
                                                                                      display to within a couple of counts of the desired reading, and the Fine Span
backlight. Terminals 3 (SIG-) and 1 (COM) are AC coupled with a capacitor.            pot is used to adjust for the exact reading.
This limits the isolation between these terminals to 50 VDC maximum.
                                                                                                           WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT
OFFSET ADJUSTMENTS                                                                                         EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF
                                                                                                           OR THE AREA IS KNOWN TO BE NON-HAZARDOUS.
   The minimum currents are not zero based with 4 to 20 mA and 10 to 50 mA
signals. To obtain a zero minimum display reading, the display must be offset.                          THISEQUIPMENTISSUITABLEFOR USE IN:
The display on the CUB4LP/CL can be offset by adjusting the Coarse and Fine                             Class I, Division 2, Groups A, B, C, and D
Offset pots.                                                                                            Class II, Division 2, Groups F and G
                                                                                                        Class III, Division 2 or Non Hazardous locations.

                                                                                   3
DECIMAL POINT POSITION SELECTION                                                    APPLICATION EXAMPLE

   The decimal point position is DIP switch selectable for one of three locations.     Operation of a refinery process required a local display of the position of a
                                                                                    remote pipeline valve. The display would indicate 0 (zero) when the valve was
The CUB4LP/CL can be set up to read in 10ths, 100ths, or 1000ths. If all the        fully closed with an input signal of 4 mA. When the valve was fully open the
                                                                                    display would indicate 100 with an input signal of 20 mA.
DIP switches are set to the "OFF" position, no decimal point will appear on the
                                                                                       Both the CUB4LP and the CUB4CL meet the necessary requirements.
display. The DIP switches are located at the rear of the unit.

                                                                                                                    +                                +
                                                                                                    CONTROL                                          - VALVE
                                                                                                    DEVICE -

                                                                                                                             SIG +

                                                                                                                             COMM
                                                                                                                             (SIG -)

                                                                                                                             CUB4LP

CALIBRATING THE DISPLAY                                                                                                BLOCK DIAGRAM

   Calibrating the CUB4LP/CL requires either an accurate adjustable constant           COM 1              0.1 f             FINE                         BACKLIGHTPROCESS
current supply or the CUB4LP/CL can be installed and scaled with the process                              50 VDC             OFFSET                             -VCIRCUITRY
sensor connected to the CUB4LP/CL. To calibrate the unit, proceed as follows.       (CL ONLY)
                                                                                                                S1                          COARSE   GND
1. Set DIP switching for the desired current range.                                   +VDC 2                                                 OFFSET             +V
2. Select the desired decimal point position.                                                                                                                         S4 S3 S2
3. Apply the minimum input signal to the CUB4LP/CL and adjust the COARSE            (CL ONLY)

    OFFSET to display the approximate desired minimum value.                           SIG- 3
4. Apply the maximum input signal to the CUB4LP/CL and adjust the COARSE
                                                                                                    12.7                     COARSE
    SPAN to display the approximate desired maximum value.                                                                    SPAN
5. Repeat steps 3 and 4 until the minimum and maximum values are within the         Connection for                     8.25
                                                                                        CUB4LP40
    desired values.
6. Apply the minimum input signal to the CUB4LP/CL and adjust the FINE                                                               FINE
                                                                                                                                     SPAN
    OFFSET to display the exact desired minimum value.
7. Apply the maximum input signal to the CUB4LP/CL and adjust the FINE              SIG+ 4

    SPAN to display the exact desired maximum value.
8. Apply the minimum input signal and verify that the display indicates

    correctly.
9. Apply the maximum input signal and verify that the display indicates

    correctly.
10. Repeat Steps 6 through 9 until display reads exact.

   Note: The CUB4LP/CL display is factory calibrated to indicate 0.0 to 100.0
      with an input of 4 to 20 mA at approximately 25C.

                                                                                    ORDERING INFORMATION

                                                                                    MODEL NO.                                     DESCRIPTION                       PART NUMBERS
                                                                                     CUB4LP                                                                           CUB4LP00
                                                                                                    Reflective LCD Loop Powered Process Indicator                     *CUB4LP40
                                                                                                                                                                      CUB4CL10
                                                                                                    Red Backlit LCD Loop Powered Process Indicator                    CUB4CL20
                                                                                                    Positive Image Transflective LCD                                  CUB4CL30
                                                                                                                                                                      CUB4CL40
TROUBLESHOOTING                                                                                     Yel/Grn Backlit LCD External Powered Process                      MLPS1000
                                                                                                    Indicator Negative Image Transmissive LCD
   For further technical assistance, contact technical
                                                                                                    Red Backlit LCD External Powered Process
support at the appropriate company numbers listed.                                                  Indicator Negative Image Transmissive LCD

                                                                                    CUB4CL          Yel/Grn Backlit LCD External Powered Process
                                                                                                    Indicator Positive Image Transflective LCD

                                                                                                    Red Backlit LCD External Powered Process
                                                                                                    Indicator Positive Image Transflective LCD

                                                                                    MLPS            Micro Line/Sensor Power Supply
                                                                                                    (Non-hazardous use only)

                                                                                    *Backlight intensity will vary depending on signal level.

Red Lion Controls              Red Lion Controls                                             Red Lion Controls                                                            Red Lion Controls
Headquarters                          Europe                                                          India                                                                               China
20 Willow Springs Circle
York PA 17406                   Softwareweg 9                                        201-B, 2nd Floor, Park Centra                                                   Unit 302, XinAn Plaza
Tel +1 (717) 767-6511     NL - 3821 BN Amersfoort                                    Opp 32 Mile Stone, Sector-30                                    Building 13, No.99 Tianzhou Road
Fax +1 (717) 764-0839     Tel +31 (0) 334 723 225                                   Gurgaon-122002 Haryana, India
                          Fax +31 (0) 334 893 793                                                                                                          ShangHai, P.R. China 200223
                                                                                          Tel +91 984 487 0503                                                      Tel +86 21 6113 3688
                                                                                                                                                                   Fax +86 21 6113 3683
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved