  Micro Programmable Controller

CPM2A

The CPM2A brick-style controllers offer one of
the most powerful, small-scale control solutions
in the industry today. They provide 20, 30, 40
or 60 I/O point CPUs, pulse I/O for position
control, multiple communications ports and a
powerful instruction set.

D Expandable up to 120 I/O points
D Peripheral and RS-232C ports standard for direct

   connection to serial devices and programming tools
D Removable terminals
D Synchronized pulse control coordinates input devices

   with control devices
D Auxiliary 24 VDC supply (AC type only)
D Relay or Transistor outputs
D Analog I/O expansion modules available
D Temperature sensor input expansion modules available
D Real-time clock
D 20 kHz high-speed counter input
D Two, 10 kHz pulse outputs for position control

   applications

Basic Configuration

Up to three Expansion I/O Modules or Special I/O Modules can be connected to any CPM2A CPU. The mounting order does not affect
the number of modules that can be mounted.

Optional Serial Com-     CPU  Expansion I/O Module Expansion I/O Module Expansion I/O Module
munications Adapters          or Special I/O Module or Special I/O Module or Special I/O Module
CPM1-CIF01/CIF11
modify the Peripheral
Port for use as an
additional serial port.

A--46 Micro Programmable Controller CPM2A
Ordering Information

J CPU

Stock Note: Shaded models are normally stocked.

Description              Input                   Output  Power   Part number    Transistor outputs
CPUs with 20 I/O points  points                  points  supply  Relay outputs
                                                                                NPN (Sinking)       PNP (Sourcing)
                         12                      8       AC      CPM2A-20CDR-A
                                                                                --                  --

                                                         DC      CPM2A-20CDR-D CPM2A-20CDT-D CPM2A-20CDT1-D

AC model  DC models

CPUs with 30 I/O points  18                      12      AC      CPM2A-30CDR-A --                   --

                                                         DC      CPM2A-30CDR-D CPM2A-30CDT-D CPM2A-30CDT1-D

AC model  DC models

CPUs with 40 I/O points  24                      16      AC      CPM2A-40CDR-A --                   --

                                                         DC      CPM2A-40CDR-D CPM2A-40CDT-D CPM2A-40CDT1-D

AC model  DC models

CPUs with 60 I/O points  36                      24      AC      CPM2A-60CDR-A --                   --

                                                         DC      CPM2A-60CDR-D CPM2A-60CDT-D CPM2A-60CDT1-D

AC model  DC models

                                                             Micro Programmable Controller CPM2A A--47
J EXPANSION I/O AND SPECIAL I/O MODULES

Stock Note: Shaded models are normally stocked.

Description                Max. number Inputs              Outputs       Output type          Part number
Expansion I/O              of Units                        8
                                                                         Relay                CPM1A-20EDR1
                           3 max.                12                      Transistor (NPN)     CPM1A-20EDT
                                                                         Transistor (PNP)     CPM1A-20EDT1
                                                 8         --            --                   CPM1A-8ED
                                                                         Relay                CPM1A-8ER
                                                 --        8             Transistor (NPN)     CPM1A-8ET
                                                                         Transistor (PNP)     CPM1A-8ET1
                                                 --        8             Analog               CPM1A-MAD01

Analog I/O                 3 max.                2         1                                  CPM1A-MAD11

Temperature Sensor Inputs  3 max.                2         --            Thermocouple         CPM1A-TS001
CompoBus/S I/O Link        1 (See Note.)                                                      CPM1A-TS002
                           3 max.                4         --            Platinum resistance  CPM1A-TS101
                                                                         thermometer          CPM1A-TS101-DA
                           1 (See Note.)         2         --                                 CPM1A-TS102
                           3 max.                                        --                   CPM1A-SRT21
                                                 2         1 analog

                                                 4         --

                                                 I/O Link of 8 input
                                                 bits and 8 output bits

DeviceNet I/O Link         3 max.                32 input bits from the --                    CPM1A-DRT21
Module                                           Master and 32 output
                                                 bits to the Master

Profibus-DP Slave          3 max.                16 bits 16 bits --                           CPM1A-PRT21
Module                                           (Inputs (Outputs                             Belden #3079A cable
                                                 from the to the
                                                 Master) Master)

                           Shielded twisted pair cable, available commercially

Note: If a CPM1A-TS002/102 is connected, only one other module (and not a CPM1A-TS002/102) can be connected.

J PROGRAMMING CONSOLES AND CABLES

Stock Note: Shaded models are normally stocked.

Product                                                                                       Part number
                                                                                              CQM1H-PRO01-E
Programming console (2 m cable attached), connects directly to peripheral port                CQM1-PRO01-E
                                                                                              C200H-PRO27-E
Programming console (2 m cable attached); order CS1W-CN114 adapter for peripheral port        C200H-CN222
                                                                                              C200H-CN422
Programming console (Requires separate cable. See below.)

Connecting cable for C200H-PRO27-E                                              2 m cable

                                                                                4 m cable

A--48 Micro Programmable Controller CPM2A
J SUPPORT SOFTWARE

Stock Note: Shaded models are normally stocked.

Product                                  Functions                                                        Part number
                                                                                                          WS02-CXPC1-EJ-Vj.j
CX-Programmer Jr.                        Windows-based programming software; reduced instruction set
                                         and networking commands.                                         WS02-CXPC1-E-Vj.j

CX-Programmer                            Full programming software package programs micro, small and
                                         larger controllers.

J SERIAL COMMUNICATIONS ADAPTERS AND CABLES

Stock Note: Shaded models are normally stocked.

CPM2A port  Name             Appearance             Comments                             Cable length     Part number
Peripheral                                                                               3.3 m (10.8 ft)  CQM1-CIF02
            RS-232C                                 Cable-mounted communication
            Adapter                                 adapter converts peripheral port to  3.3 m (10.8 ft)  CPM1-CIF01
                                                    DB9-pin serial port.

                                                    DIN mount communication adapter
                                                    converts peripheral port to DB9-pin
                                                    serial port.

RS-232C     RS-232C                                 Program download cable from          2 m (6.6 ft)     C200HS-CN220-EU
            Cable                                   computer to Omron DB9 serial         3 m (9.8 ft)     CBL-202*
                                                    port.                                                 C200H-CN320-EU
                                                                                                          CBL-804*
                                                    Communication cable to other Om-                      C200H-CN520-EU
                                                    ron devices with DB9 serial port
                                                                                                          NT31C-CN510-EU
                                                    Communication cable to other Om-     5 m (16.4 ft)    NT31C-CN320-EU
                                                    ron devices with DB9 serial port                      CBL-803*
                                                                                         50 cm            NT31C-CN520-EU
                                                    Communication cable for NT31C        3m
                                                    (port "B" only).                                      C200H-CN229-EU
                                                                                                          CBL-202*
Peripheral  RS-422/                                 Communication cable for NT31C        5m               XW2Z-200S
            RS-485                                  (port "B" only).                     2m               XW2Z-500S
            Adapter                                                                                       CPM1-CIF11
                                                    Programmable download cable          2m
                                                    from D-sub 9-pin computer port to    5m
                                                    RS-232C port.                        3.3 m (10.8 ft)

                                                    Programmable download cable
                                                    from D-sub 25-pin computer port to
                                                    RS-232C port.

                                                    Converts CPM2A peripheral port to
                                                    RS-422/RS-485 communications.

* Available in Canada only.

J BATTERY

Stock Note: Shaded models are normally stocked.

Product                                  Function                                                         Part number
Backup Battery Replacement                                                                                CPM2A-BAT01
                                         Backs up memory in the CPM2A CPU Unit. (One battery is al-
                                         ready installed in the unit.)

J PROGRAM TRANSFER EQUIPMENT

Stock Note: Shaded models are normally stocked.

                                                    Micro Programmable Controller CPM2A A--49
Product                Description                                                                    Part number
Expansion Memory Unit                                                                                 CPM1-EMU01-V1
                        Uploads and downloads program and setup memory areas to and
EEPROM (256 kbits)     from the controller.                                                           EEPROM-CPM1-EMU01

J MANUALS               Used with the Expansion Memory Unit

Product                Description                                                                    Part number
Operation manual       CPM2A operation manual                                                         W352
Programming manual     CPM1/CPM1A/CPM2A/CPM2C/SRM1(-V2) Programming Manual                            W353

Specifications

J GENERAL SPECIFICATIONS

Item                                    CPUs with               CPUs with            CPUs with         CPUs with
                                        20 I/O points           30 I/O points        40 I/O points     60 I/O points
Supply voltage
                       AC power         100 to 240 VAC, 50/60 Hz
Operating voltage      DC power
range                  AC power         24 VDC
Power consumption      DC power
                       AC power         85 to 264 VAC
Inrush current         DC power
                       AC power         20.4 to 26.4 VDC
External power         DC power
supply (AC power       Supply voltage   60 VA max.
supplies only)         Output capacity
Insulation resistance                   20 W max. (See separate table following this one for details)
Dielectric strength    AC power
                       DC power         60 A max.
Noise immunity
Vibration resistance                    20 A max.

Shock resistance                        24 VDC
Ambient temperature
                                        300 mA (See Notes 1, 2, 3.)
Humidity
Atmosphere                              20 M min. (at 500 VDC) between the external AC terminals and protective earth terminals.
Terminal screw size
Power interrupt time                    2,300 VAC 50/60 Hz for 1 min between the external AC and protective earth terminals, leak-
                                        age current: 10 mA max.
CPU weight
                                        Conforms to IEC61000-4-4, 2 kV (power lines)
Expansion weight
                                        10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s2 in X, Y, and Z direc-
                                        tions for 80 minutes each.
                                        (Time coefficient; 8 minutes coefficient factor 10 = total time 80 minutes)

                                        147 m/s2 three times each in X, Y, and Z directions.

                                        Operating: 0 to 55C

                                        Storage: --20 to 75C

                                        10% to 90% (with no condensation)

                                        Must be free from corrosive gas

                                        M3

                                        AC power supply: 10 ms min.
                                        DC power supply: 2 ms min.

                                        650 g max.              700 g max.           800 g max.        1,000 g max.

                                        550 g max.              600 g max.           700 g max.        900 g max.

                                        Units with 20 I/O points:        300 g max.
                                        Units with 8 output points:      250 g max.
                                        Units with 8 input points:       200 g max.
                                        MAD01 Analog I/O Unit:           150 g max.
                                        MAD11 Analog I/O Unit:           250 g max.
                                        Temperature Sensor Units:        250 g max.
                                        CompoBus/S I/O Link Unit:        200 g max.
                                        DeviceNet I/O Link Unit:         200 g max.
                                        Profibus-DP Slave Unit:          125 g

Note: 1.    Use the external power supply as the power supply for input devices only. (It cannot be used to drive output devices.)
        2.  If the external power supply current exceeds the rated current, or there is a short-circuit, the external power supply voltage will
            drop and PLC operation will stop.
        3.  If there are 3 CPM1A-MAD11 modules mounted to a CPM2A-60CDR-A, the current for the external power supply must not
            exceed 200 mA.

A--50 Micro Programmable Controller CPM2A
J CHARACTERISTICS

Control method             Stored program method
I/O control method
Programming language       Cyclic scan with direct output (Immediate refreshing can be performed with IORF(97).)
Instruction length
Instructions               Ladder diagram

                           1 step per instruction, 1 to 5 words per instruction

                           Basic instructions: 14
                           Special instructions: 105 instructions, 185 variations

Execution time             Basic instructions: 0.64 s (LD instruction)
                           Special instructions: 7.8 s (MOV instruction)

Program capacity           4,096 words

User data memory           2,048 words

I/O       CPU Unit only    20 points              30 points                        40 points        60 points
capacity
          With Expansion   80 points max.         90 points max.                   100 points max.  120 points max.
          I/O Modules

Memory protection          HR area, AR area, program contents, read/write DM area contents, and counter values maintained
                           during power interruptions.
Memory backup
                           Flash memory:
Self-diagnostic functions  Program, read-only DM area, and PC Setup
Program checks
Communications functions   Battery backup:
                           The read/write DM area, HR area, AR area, and counter values are backed up by a battery. (Battery life
Functions provided by      is approximately 5 years.)
Expansion Modules
                           CPU failure (watchdog timer), I/O bus error, and memory failure, battery error

                           No END instruction and programming errors are checked at the start of operation.

                           Built-in peripheral port:
                           Supports host link, peripheral bus, no-protocol, or Programming Console connections.

                           Built-in RS-232C port:
                           Supports Host Link, No-protocol, 1:1 Slave Unit link, 1:1 Master Unit link, or 1:1 NT Link connections.

                           Analog I/O Module: Provides 2 analog inputs and 1 analog output.

                           CompoBus/S I/O Link Module: Provides 8 inputs and 8 outputs as a CompoBus/S Slave.

                           Temperature Sensor Modules: Provide 2 or 4 thermocouple inputs, or 2 or 4 temperature-resistance
                           thermometer inputs.

                                                  Micro Programmable Controller CPM2A A--51
J I/O ALLOCATION

Input bits                   IR 00000 to IR 00915 (Words not used for input bits can be used for work bits.)
Output bits
Work bits                    IR 01000 to IR 01915 (Words not used for output bits can be used for work bits.)

Special bits (SR area)       928 bits: IR 02000 to IR 04915 (Words IR 020 to IR 049) and IR 20000 to IR 22715 (Words IR 200 to
Temporary bits (TR area)     IR 227)
Holding bits (HR area)
Auxiliary bits (AR area)     448 bits: SR 22800 to SR 25515 (Words IR 228 to IR 255)
Link bits (LR area)
Timers/Counters              8 bits (TR0 to TR7)

Data memory                  320 bits: HR 0000 to HR 1915 (Words HR 00 to HR 19)

Basic in-  Interrupt         384 bits: AR 0000 to AR 2315 (Words AR 00 to AR 23)
terrupts   processing
                             256 bits: LR 0000 to LR 1515 (Words LR 00 to LR 15)
High-      Interval timer
speed      interrupts        256 timers/counters (TIM/CNT 000 to TIM/CNT 255)
counter
           High-speed                     1-ms timers: TMHH(----)
           counter                        10-ms timers: TIMH(15)
                                          100-ms timers: TIM
           Interrupt inputs               1-s/10-s timers: TIML(----)
           (counter mode)                 Decrementing counters: CNT
                                          Reversible counters: CNTR(12)
Pulse output
                             Read/Write: 2,048 words (DM 0000 to DM 2047)
Synchronized pulse control   Error Log is contained in DM 2000 to DM 2021
                             Read-only: 456 words (DM 6144 to DM 6599)
Quick-response inputs        PC Setup: 56 words (DM 6600 to DM 6655)
Analog controls
Input time constant          External interrupts: 4
                             (Shared by the external interrupt inputs (counter mode) and the quick-response inputs.)
Clock function               1 (Scheduled Interrupt Mode or Single Interrupt Mode)

                             One high-speed counter: 20 kHz single-phase or 5 kHz two-phase (linear count method)

                             Counter interrupt: 1 (set value comparison or set-value range comparison)
                             Four inputs (Shared with external interrupt inputs (counter mode) and quick-response inputs.)

                             Counter interrupts: 4 (Shared by the external interrupt inputs and quick-response inputs.)
                             Two points with no acceleration/deceleration, 10 to 10 kHz each, and no direction control.
                             One point with waveform acceleration/deceleration, 10 to 10 kHz, and direction control.
                             Two points with variable duty-ratio outputs using PWM(----).

                             (Pulse outputs can be used with transistor outputs only, they cannot be used with relay outputs.)

                             One point:
                             A pulse output can be created by combining the high-speed counter with the pulse output and multiply-
                             ing the frequency of the input pulses from the high-speed counter by a fixed factor.

                             (This output is possible with transistor outputs only, it cannot be used with relay outputs.)
                             Four points (Min. input pulse width: 50 s min.)
                             2 controls, setting range: 0 to 200

                             Can be set for all input points.
                             (1 ms, 2 ms, 3 ms, 5 ms, 10 ms, 20 ms, 40 ms, or 80 ms; default setting: 10 ms)

                             Shows the year, month, day of the week, day, hour, minute, and second. (Battery backup)

A--52 Micro Programmable Controller CPM2A
J I/O SPECIFICATIONS

CPU Input

Item                   Inputs              Specification                                              Input
Input voltage          All                 24 VDC +10%/--15%                                          LED
Input impedance        IN00000 to IN00001  2.7 k
                       IN00002 to IN00006  3.9 k                                                             Internal
Input current          IN00007 and up      4.7 k                                                             Circuits
                       IN00000 to IN00001  8 mA typical
ON voltage/current     IN00002 to IN00006  6 mA typical
                       IN00007 and up      5 mA typical
OFF voltage/current    IN00000 to IN00001  17 VDC min., 5 mA
ON delay               IN00002 and up      14.4 VDC min., 3 mA
OFF delay              All                 5.0 VDC max., 1 mA
Circuit configuration  All                 1 to 80 ms max. Default: 10 ms (See Note.)
                       All                 1 to 80 ms max. Default: 10 ms (See Note.)
                       IN00000 to IN00001
                                                                                           10,000 pF

                                                                              2.7 k 680

                       IN00002 to IN00006                                                             Input
                                                                                                      LED
                                                             750
                                                        3.9 k                                               Internal
                                                                                                            Circuits

                       IN00007 and up                                                                 Input
                                                                                                      LED
                                                             750
                                                        4.7 k                                                Internal
                                                                                                             Circuits

Note: The input time constant can be set to 1, 2, 3, 5, 10, 20, 40, or 80 ms in the PLC Setup.

High-speed Counter Inputs

Inputs IN00000 through IN00002 can be used as high-speed counter inputs, as shown in the following table. The maximum count fre-
quency is 5 kHz in differential phase mode and 20 kHz in the other modes.

Input    Function

IN00000  Differential phase mode       Pulse + direction input mode Up/down input mode                Increment mode
IN00001
IN00002  A-phase pulse input           Pulse input      Increment pulse input                         Increment pulse input

         B-phase pulse input           Direction input  Decrement pulse input                         Normal input

         Z-phase pulse input/Hardware reset input (IN00002 can be used as a normal input when it is not used as a high-speed
         counter input.)

Interrupt Inputs

Inputs IN00003 through IN00006 can be used as interrupt inputs (interrupt input mode or counter mode) and quick-response inputs. The
minimum pulse width for these inputs is 0.05 ms.

                                                        Micro Programmable Controller CPM2A A--53
Expansion I/O Module Input

Item                     Specification
Input voltage            24 VDC +10%/--15%
Input impedance          4.7 k
Input current            5 mA typical
ON voltage               14.4 VDC min.
OFF voltage              5.0 VDC max.
ON delay                 1 to 80 ms max. Default: 10 ms (See note.)
OFF delay                1 to 80 ms max. Default: 10 ms (See note.)
Circuit configuration

                                                       750           Input
                                                 4.7 k               LED

                                                                            Internal
                                                                            Circuits

Note: The input time constant can be set to 1, 2, 3, 5, 10, 20, 40, or 80 ms in the PLC Setup.

J OUTPUT SPECIFICATIONS (CPU AND EXPANSION I/O MODULE)

Relay Output

Item                     Specification
Max. switching capacity
                         2 A, 250 VAC (cos = 1)
Min. switching capacity  2 A, 24 VDC
Service life of relay    (4 A/common)

ON delay                 10 mA, 5 VDC
OFF delay
Circuit configuration    Electrical:   150,000 operations (30 VDC resistive load)
                         Mechanical:   100,000 operations (240 VAC inductive load, cos = 4)

                                       20,000,000 operations

                         15 ms max.

                         15 ms max.

                                                             Output                             OUT
                                                             LED

                                                 Internal                                       OUT
                                                 Circuits
                                                                                                COM Maximum
                                                                                                          250 VAC: 2 A
                                                                                                          24 VDC: 2 A

A--54 Micro Programmable Controller CPM2A
Transistor Output (Sinking)

Item                     Specification
Max. switching capacity
                         20CDT-D        30CDT-D     40CDT-D                60CDT-D         8ET         20EDT1
Leakage current                                                                                        24 VDC+10%/--5%,
Residual voltage         OUT01000, 01001: 4.5 to 30 VDC, 0.2 A/output                                  0.3 A/output
ON delay                 OUT01002 and up: 4.5 to 30 VDC, 0.3 A/output                                  0.9 A/common
OFF delay                                                                                              1.8 A/Unit
                         0.8 A/common 0.8 A/common 0.8 A/common 0.8 A/common 0.9 A/common
Fuse (See Note)                                                                                        0.1 ms max.
Circuit configuration    1.6 A/Unit     2.4 A/Unit  3.2 A/Unit             4.8 A/Unit      1.8 A/Unit
                                                                                                       1 ms max.
                         0.1 mA max.                                                                   24 VDC
                                                                                                       +10%/--5%,
                         1.5 V max.                                                                    5 to 300 mA)
                                                                                                       1 fuse/common
                         OUT01000 and OUT01001: 20 s max.

                         OUT01002 and up:           0.1 ms max.

                         OUT01000 and OUT01001: 40 s max. (4.5 to 26.5 V, 10 to 100 mA)

                                                    0.1 ms max. (4.5 to 30 V, 10 to 300 mA)

                         OUT01002 and up:           1 ms max. (4.5 to 30 V, 10 to 300 mA)

                         1 fuse/output

                                                                       Output              OUT
                                                                       LED

                                                    Internal                               OUT 24 VDC
                                                    Circuits                               COM (--)

Note: Cannot be replaced by the user.

Transistor Output (Sourcing)

Item                     Specification
Max. switching capacity
                         20CDT1-D       30CDT1-D    40CDT1-D               60CDT1-D        8ET1        20EDT1
Leakage current                                                                                        24 VDC+10%/--5%,
Residual voltage         OUT01000, 01001: 4.5 to 30 VDC, 0.2 A/output                                  0.3 A/output
ON delay                 OUT01002 and up: 4.5 to 30 VDC, 0.3 A/output                                  0.9 A/common
OFF delay                                                                                              1.8 A/Unit
                         0.8 A/common 0.8 A/common 0.8 A/common 0.8 A/common 0.9 A/common
Fuse (See Note)                                                                                        0.1 ms max.
Circuit configuration    1.6 A/Unit     2.4 A/Unit  3.2 A/Unit             4.8 A/Unit      1.8 A/Unit
                                                                                                       1 ms max.
                         0.1 mA max.                                                                   24 VDC+10%/--5%,
                                                                                                       5 to 300 mA)
                         1.5 V max.                                                                    1 fuse/common

                         OUT01000 and OUT01001: 20 s max.

                         OUT01002 and up:           0.1 ms max.

                         OUT01000 and OUT01001: 40 s max. (4.5 to 26.5 V, 10 to 100 mA)

                                                    0.1 ms max. (4.5 to 30 V, 10 to 300 mA)

                         OUT01002 and up:           1 ms max. (4.5 to 30 V, 10 to 300 mA)

                         1 fuse/output

                                                                           Output
                                                                           LED

                                                                 Internal                    COM (+)
                                                                 Circuits                    OUT 24 VDC

                                                                                             OUT

Note: Cannot be replaced by the user.

                                                    Micro Programmable Controller CPM2A A--55
J ANALOG I/O MODULE

Up to 3 Expansion I/O Modules or Expansion Modules (including
the CPM1A-MAD01 Analog I/O Module) can be connected to a
CPM2A CPU.

                                                                           CPM1A--MAD01                      CPM1A--MAD11

Item                            CPM1A-MAD01                                CPM1A-MAD11

                                Voltage I/O           Current I/O          Voltage I/O                   Current I/O
                                                                           2 (allocated 2 words)
Analog    Number of inputs      2                                          0 to 5 V, 1 to 5 V, 0 to      0 to 20 mA, 4 to 20 mA
inputs    Input signal ranges                                              10 V, --10 to 10 V            30 mA
                                0 to 10 V or 1 to 5 V 4 to 20 mA           15 V                         250
          Maximum rated input                                              1 M min.
          External input        15 V                 30 mA
          impedance             1 M min.              250  rated
          Resolution
          Overall precision     1/256                                      1/6,000 (full scale)
                                1.0% of full scale
                                                                           25_C:          0.3% of full 25_C:       0.4% of full
                                                                                          scale                     scale

                                                                           0 to 55_C: 0.6% of full 0 to 55_C: 0.8% of full

                                                                                          scale                     scale

          Converted A/D data    8-bit binary                               Binary data (4-digit hexadecimal)

                                                                           --10 to 10 V:         F448 to 0BB8 Hex full scale

                                                                           Other:                0000 to 1770 Hex full scale

Analog    Averaging             --                                         Supported (set for each input with DIP switch)
output    Disconnected line     --
(See      detection                                                        Supported
Note 1.)  Number of outputs
          Output signal ranges  1                                          1 (allocated 1 word)
                                                      4 to 20 mA                                         0 to 20 mA, 4 to 20 mA
          External output max.  0 to 10 V or --10 to  --                   1 to 5 V, 0 to 10 V, --10 to  --
          current               10 V                                       10 V

          External output       5 mA                                       --
          allowed load
          resistance            --                    350                  1 k min.                      600  max.

          External output       --                                         0.5  max.                     --
          impedance
                                1/256 (1/512 when the output signal range  1/6,000 (full scale)
          Resolution            is --10 to 10 V.)
                                1.0% of full scale
          Overall precision                                                25_C: 0.4% of full scale
                                8-bit binary with sign bit
                                --                                         0 to 55_C: 0.8% of full scale

          Data setting          10 ms/Unit max.                            --
          D/A data setting      Photocoupler isolation between I/O termi-
                                nals and PC                                Binary data (4-digit hexadecimal)
                                (There is no isolation between the analog
                                I/O signals.)                              --10 to 10 V:         F448 to 0BB8 Hex full scale

                                                                           Other:                0000 to 1770 Hex full scale

Conversion time (See Note 2.)                                              2 ms/point (6 ms/all analog I/O)
Isolation method
                                                                           Photocoupler isolation between analog I/O and inter-
                                                                           nal circuits. (Individual analog I/O signals are not iso-
                                                                           lated.)

Note: 1. The voltage output and current output can be used at the same time, but the total output current cannot exceed 21 mA.
        2. The conversion time is the total time for 2 analog inputs and 1 analog output.

A--56 Micro Programmable Controller CPM2A
J TEMPERATURE SENSOR MODULES

By connecting a Temperature Sensor Module
(CPM1A-TS001/TS002/TS101/TS101A/TS102) to the CPM2A,
inputs can be received from thermocouples or temperature-
resistance thermometers. Inputs converted to binary data (4-digit
hexadecimal) and stored in the IR area.

Specifications

Item               Specification                          CPM1A-TS101/TS102                     CPM1A-TS101-DA
Model              CPM1A-TS001/TS002
Number of inputs   TS001: 2; TS002: 4                     TS101: 2; TS102: 4                    2
Input types        Thermocouple types K or J, selectable
(See Note 1)                                              Platinum resistance thermometer types Pt100 and JPt1100, selectable
Input resolution
Input accuracy     0.1C in 2's complement format         0.1C in 2's complement format        1.0% max. full scale
                   0.5% or 2% of the stored value       0.5% or 1% of the stored value
Number of outputs  whichever is larger 1 digit max.      whichever is larger 1 digit max.     1
Output types       (See Note 2)                           (See Note 2)                          Voltage or current output
Output resolution  None                                   None                                  1/256 (0 to 10 V)
                   --                                     --                                    1/512 (--10 to +10 V)
Output accuracy    --                                     --                                    1/256 (4 to 20 mA)
Conversion cycle                                                                                1.0% max. full scale
Converted          --                                     --                                    60 ms max. for all points
temperature data   250 ms for all points                                                        Binary data (8-digit hexadecimal)
Isolation method   Binary data (4-digit hexadecimal)

                   Photocoupler isolation between I/O terminals and the PLC

Note: 1. The same input type must be used for all inputs.
        2. Accuracy for K thermocouples at temperatures less than --100C: 4C 1 digit max.

Input Temperature Ranges

The input type is selected with a rotary switch. The ranges for each of the input types are shown in the following table.

Model           CPM1A-TS001/TS002                                          CPM1A-TS101/TS101-DA/TS102
Input type      Thermocouple type K
Range in C     --200 to 1,300, 0.0 to 500.0  Thermocouple type J          Platinum RTD Pt100      Platinum RTD JPt100
Range in F     --300 to 2300, 0.0 to 900.0   --100 to 850, 0.0 to 400.0
                                              --100 to 1500, 0.0 to 750.0  --200.0 to 650.0        --200.0 to 650.0

                                                                           --300.0 to 1200.0       --300.0 to 1200.0

                                                                   Micro Programmable Controller CPM2A A--57
J COMPOBUS/S I/O LINK MODULE

The CPM2A PLC can function as a Slave to a CompoBus/S Master Module (or SRM1 CompoBus/S Master Controller) when a CPM1A-
SRT21 CompoBus/S I/O Link Module is connected. The CompoBus/S I/O Link Module establishes an I/O link of 8 inputs and 8 outputs
between the Master Module and the CPM2A. Up to 3 Expansion I/O Modules or Expansion Modules can be connected to a CPM2A CPU.

CompoBus/S Master Module     CPM2A CPU                                         CPM1A-SRT21
(or SRM1 CompoBus/S                                                            CompoBus/S I/O
Master Controller)                                                             Link Module

CS1j, C200Hj,
CQM1 (H), or SRM1 PC

                      SCA1-4F10 flat cable or twisted pair Belden #9409 cable  Up to 16 Slaves can be connected.
                                                                               (Up to 8 Slaves with the CQM1-SRM21-V1.)

Specifications

Item                         Specification
Model number                 CPM1A-SRT21
Master/Slave                 CompoBus/S Slave
Number of I/O bits           8 input bits, 8 output bits
Number of words occupied in  1 input word, 1 output word
CPM2A I/O memory             (Allocated in the same way as other Expansion I/O Units or Expansion Units)
Node number setting          Set using the DIP switch.

Note: See the CompoBus/S section of Omron's Remote I/O and Wiring Solutions Catalog (GC RIO1)for more details on CompoBus/S
         communications.

J CPM1A-DRT21 DEVICENET I/O LINK MODULE

The CPM1A-DRT21 DeviceNet I/O Link Module can be connected to the CPM2A to function as a slave under a DeviceNet Master Mod-
ule. This enables an I/O Link with the Master Module via 32 input and 32 output points.

                             CPM2A CPU Module  CPM1A--DRT21 DeviceNet I/O Link Module

DeviceNet Master Module

CS1j, C200Hj, CJ1j,                            Connect up to 63 nodes
CV-series or CVM1                              (with an CS1 Master Module)
PLC

A--58 Micro Programmable Controller CPM2A
Specifications

Item                                                   Specification
Model number
Master/slave                                           CPM1A-DRT21
I/O capacity to master
I/O memory allocated in CPM2A                          DeviceNet slave
Node address setting
Maximum number of nodes (depending on the PC to which  32 input and 32 output points
Master Unit is mounted)
                                                       2 input words and 2 output words (same as other Expansion Units)

                                                       DIP switch (Set before turning ON power for the CPU Unit.)

                                                       CS1:              63 nodes
                                                       CJ1:              63 nodes
                                                       CVM1/CV           32nodes
                                                       C200HX/HG/HE:     25 nodes
                                                       C200HS            16 nodes

J PROFIBUS-DP SLAVE MODULE

The CPM2A controller can function as a Slave to a Profibus-DP Master Module when a CPM1A-PRT21 Profibus-DP Slave Module is
connected. The Profibus-DP Slave Module establishes an I/O link of 16 inputs and 16 outputs between the master and the controller. A
maximum of 3 Profibus-DP Slave Modules can be connected to a CPM1A or CPM2A to create I/O links for up to 96 points (48 inputs and
48 outputs).

Profibus-DP Master Module

                           PLC supporting Profibus-DP Master,
                           e.g., CSI, C200Hj, CJ1j

                                                       CPM2A CPU Module               CPM1A-PRT21 Profibus-DP
                                                                                      Slave Module

                                                                                                         Each module enables

                                                                                      PRT21              remote I/O communica-

                                                                                                         tions for 16 inputs and

                                                                                                         16 output points as a

                                                                                                         Profibus-DP Slave.

                                          Shielded twisted pair                       Up to 124 nodes
                                          Belden #3079A cable                         (using repeaters)

Specifications             --20 to +75C
                           0 to +55C
Storage temperature       10 to 90% (non-condensing)
Ambient temperature       EN 50081-2, EN 61131-2
Ambient humidity          100 mA from the PLC I/O bus
EMC compliance            125 g (typical)
Current consumption       From CPU to unit: none
Weight                    From unit to CPU: none
Control data              2 bytes input, 2 bytes output
Status data
I/O data (in bytes)

                                                                 Micro Programmable Controller CPM2A A--59
J COMMUNICATIONS ADAPTER

RS-232C Adapter and RS-422 Adapter                                        CPM1--CIF01          CPM1--CIF11

Part number                      CPM1-CIF01                                        CPM1-CIF11
Functions
                                 Level conversion between the CMOS level           Level conversion between the CMOS level
Insulation                       (CPU side) and the RS-232C (peripheral            (CPU side) and the RS-422 (peripheral device
                                 device side)                                      side)
Power supply
Power consumption                The RS-232C (peripheral device side) is insu- The RS-422 (peripheral device side) is insu-
Transmission speed               lated by a DC/DC converter and photocoupler. lated by a DC/DC converter and photocoupler.
Vibration resistance
                                 Power is supplied by the CPU.
Shock resistance
Ambient temperature              0.3 A max.

Ambient humidity                 38.4 kbits/s max.
Ambient environment
Weight                           10 to 57 Hz with an amplitude of 0.075 mm, and 57 to 150 Hz with an acceleration of 1 G in the X,
                                 Y and Z directions for 80 minutes each (i.e. for 8 minutes each, 10 times).

                                 1.5 G in the X, Y and Z directions 3 times each.

                      Operating  0C to 55C (32F to 131F)                       0C to 55C (32F to 131F)
                      Storage
                      Operating  --20C to 75C (--4F to 167F)                   --20C to 75C (--4F to 167F)
                      Operating
                                 10% to 90% RH (with no condensation)

                                 With no corrosive gas

                                 200 g max.

A--60 Micro Programmable Controller CPM2A
Dimensions                                                                        CPUs with DC Power      CPUs with AC Power

Unit: mm (inch)

J CPU

CPM2A-20CDj-j/30CDj-j

                                                                    90
                                                                  (3.54)

                                          130 (5.12)                                           55 (2.17)              90 (3.54)

CPM2A-40CDj-j                                                                     CPUs with DC Power      CPUs with AC Power

                                                                            90
                                                                          (3.54)

                                                     150 (5.91)                           55 (2.17)       90 (3.54)

CPM2A-60CDj-j

                                                                                  CPUs with DC Power      CPUs with AC Power

                                                                                    90
                                                                                  (3.54)

                                                      195 (7.68)                          55 (2.17)       90 (3.54)

                                                                          Micro Programmable Controller CPM2A A--61
J EXPANSION I/O AND SPECIAL I/O MODULES                                            CPM1A-8jjj Expansion I/O Modules

CPM1A-20EDj Expansion I/O Modules

                        90                                                                                              90
                      (3.54)                                                                                          (3.54)

           86 (3.39)                                                    50 (1.97)                       66 (2.60)                     50 (1.97)

CPM1A-MAD01 Analog I/O Module                                                      CPM1A-MAD11 Analog I/O Module

                                                                  90                                                               5
                                                                (3.54)
                                                                                                                                      100
                                                                                                                                     0.2
                                                                                                                                 90

                                                                                              76 0.2             5              8
                                                                                                 86
           66 (2.60)                                                                                                              50

                                                                        50 (1.97)                                  Two, 4.5 dia.

CPM1A-TSjjj Temperature Sensor Input Modules

Two, 10               73 (2.99)
dia. hole

                                                                          90
                                                                        (3.54)

           43 (1.69)                                                               50 (1.97)
                         86 (3.39)

A--62 Micro Programmable Controller CPM2A
Unit: mm (inch)                                       CPM1A-DRT21 DeviceNet I/O Link Module

CPM1A-SRT21 CompoBus/S I/O Link Module

                                  90
                                (3.54)

                     66 (2.60)             50 (1.97)

CPM1A-PRT21 Profibus-DP Slave Module

J COMMUNICATION ADAPTER MODULES

CPM1-CIF01                                            CPM1-CIF11

          30 (1.18)             56 (2.20)                         30 (1.18)  61 (2.40)
              21                     50                                21           50

90                                                    90
(3.54)                                                (3.54)

      81                                                     81

                                                      Micro Programmable Controller CPM2A A--63
Functions

J CONFIGURATION                                                       The CPM2A easily communicates with personal computers, other
                                                                      OMRON PLCs, and OMRON Programmable Terminals. These
The CPM2A PLCs incorporate a variety of features, including           communications capabilities allow the user to design a low-cost
synchronized pulse control, interrupt inputs, pulse outputs,          distributed production system.
analog settings, and a clock function. Use the CPM2A CPU as a
stand-alone controller for a broad range of machine control
applications.

                                                                      The CPU contains 20, 30, 40, or 60 I/O points and Expansion I/O
                                                                      blocks can be added to provide a total I/O capacity of up to 120 I/O
                                                                      points. Analog I/O modules, Temperature Sensor modules, and
                                                                      CompoBus/S I/O Link modules can also be connected.

Peripheral Port                                                       RS-232C Port
Use this port for programming devices (compa-                         This port can be used for a Host
tible with other OMRON PLCs) as well as Host                          Link, no-protocol, 1:1 data link, or
Link and no-protocol communications.                                  1:1 NT Link communications.

J TIME-PROPORTIONAL CONTROL                                           For temperature monitoring applications, CPM2A accepts up to 6
                                                                      inputs (two per module) from Temperature Sensor Input modules.
The CPM2A performs simple-to-program, time-proportional               The PID instruction can manipulate the input from either
control using up to three Analog I/O modules (maximum 6 analog        thermocouple or platinum resistance thermometer sensors.
inputs and 3 analog outputs) and the PID and PWM expansion
instructions. These instructions set the parameters for PID
control and a pulse output with variable duty ratio. For increased
reliability, an open-circuit detection function can be used with the
1 to 5 VDC and 4 to 20 mA analog input settings.

J DISTRIBUTED I/O CONTROL                                             Master   CompoBus/S Master Module                    CompoBus/S I/O
                                                                        PLC                                                   Link Module
Omron's CompoBus/S Network provides distributed CPU control                                                       CPM2A
based on a "PLC + compact PLC" configuration which provides                                                       (Slave)
improvements over distributed control based on "PLC + remote
I/O" configurations. The distributed CPU control makes                Distributed                                          CompoBus/S
equipment module, so designs can be standardized, special             CPU control
needs can be addressed and modules can be replaced easily in
the event of breakdown without affecting the main CPU.

J BUILT-IN MOTOR CONTROL CAPABILITY

Synchronized Pulse Control (transistor output models only)            Encoder      CPM2A                                   3G3MV Drive
                                                                                                                                                 Motor
Synchronized output pulse control provides an easy way to
coordinate the operation of a peripheral piece of equipment with      Pulses are output as a fixed multiple of the input frequency.
the main equipment. The output pulse frequency can be
controlled as a multiple of the input pulse frequency, allowing the
speed of a peripheral piece of equipment (such as a supply
conveyor) to be synchronized with the speed of the main piece of
equipment.

A--64 Micro Programmable Controller CPM2A
J HIGH-SPEED COUNTERS AND INTERRUPTS

The CPM2A has a total of five high-speed counter inputs. The        Easy Position Control with Pulse Outputs
one high-speed counter input has a response frequency of            (transistor output models only)
20 kHz/5 kHz, and the four interrupt inputs (in counter mode)
have a response frequency of 2 kHz.                                 The CPM2A PLCs with transistor outputs have two outputs that
                                                                    can produce 10 Hz to 10 kHz pulses (single-phase outputs).
Four Input Modes
                                                                    When used as single-phase pulse outputs, there can be two
The high-speed counter can be used in any one of the four input     outputs with a frequency range of 10 Hz to 10 kHz with a fixed
modes: differential phase mode (5 kHz), pulse plus direction input  duty ratio or 0.1 to 999.9 Hz with a variable duty ratio (0 to 100%
mode (20 kHz), up/down pulse mode (20 kHz), or increment            duty ratio).
mode (20 kHz). Interrupts can be triggered when the count
matches a set value or falls within a specified range.              When used as pulse plus direction or up/down pulse outputs,
                                                                    there can be just one output with a frequency range of 10 Hz to
Interrupt Inputs                                                    10 kHz.

The interrupt inputs (counter mode) can be used for incrementing
counters or decrementing counters (2 kHz) and trigger an
interrupt (executing the interrupt program) when the count
matches the target value. Use this for target-value comparison or
range comparison control that is unaffected by the cycle time.

                           Counter inputs

                           Reset inputs (for differential phase inputs)

                                                                                    Sensor   Rotary encoder
                                                                                            (such as E6C2-C)

Input  Response frequency  Input mode (count value)                                 Control method
       5 kHz
00000  20 kHz              Differential phase input mode (-8,388,608 to 8,388,607)  Target value comparison interrupts
00001                                                                               Range comparison interrupts
00002                      Pulse + direction input mode (-8,388,608 to 8,388,607)
                           Up/down pulse input mode (-8,388,608 to 8,388,607)
                           Increment mode (0 to 16,777,215)

                                                                    Micro Programmable Controller CPM2A A--65
J PULSE OUTPUTS

The CPM2A has two pulse outputs. You can configure these outputs as two single-phase outputs without acceleration and deceleration,
two variable duty-ratio pulse outputs, or pulse outputs with trapezoidal acceleration/deceleration (one pulse + direction output and one
up/down pulse output). The pulse output's PV coordinate system can also be specified in the PLC Setup as either relative or absolute.

                                                                                                                                                 Stepping motor

                                                                                          SmartStep Servodriver

                                            Pulse outputs

Item                        Single-phase pulse             Variable duty-ratio  Single-phase pulse output with trapezoidal
                                                                                acceleration/deceleration
                            output without                 pulse output

                            acceleration/deceleration                           Pulse + direction output    Up/down pulse output

Controlling instruction(s)  PULS(65) and SPED(64)          PWM(-- -- )          PULS(65) and ACC(----)

Output  01000               Pulse output 0                 Pulse output 0       Pulse     Pulse output      Pulse  CW pulse
number                      (See Note.)                    (See Note.)
                            Pulse output 1                 Pulse output 1       output 0                    output 0 output
                            (See Note.)                    (See Note.)
        01001               10 Hz to 10 kHz                0.1 Hz to 999.9 Hz             Direction output         CCW pulse
                                                                                                                   output
                            10 Hz                          0.1 Hz
Output frequency range                                                          10 Hz to 10 kHz             10 Hz to 10 kHz
                   Pitch    50%                            0 to 100%
                                                                                10 Hz                       10 Hz
Duty ratio
                                                                                50%                         50%

Note: With single-phase pulse outputs, pulse outputs 0 and 1 can each be output independently.

Application Example: Adjusting Film/Paper Web Speed in Packaging and Printing

        SYSDRIVE Inverter

                            Encoder

                                                                                          CPM2A PLC

                            Main Motor

                                                           W-Series Servo Motor/Servo Drive

A--66 Micro Programmable Controller CPM2A
J HIGH-SPEED INPUT CAPABILITIES FOR                                  J OTHER FUNCTIONS
    MACHINE CONTROL
                                                                     Analog Settings
High-speed Interrupt Input Function
                                                                     There are two controls on the CPU that can be turned to change
There are four inputs used for interrupt inputs (shared with quick-  the analog settings (0 to 200 BCD) of timers and counters. These
response inputs and interrupt inputs in counter mode) with a         controls can be used to easily change or fine-tune machine
minimum input signal width of 50 s and a response time of           settings such as a conveyor belt's pause time or feed rate.
0.3 ms. When an interrupt input goes ON, the main program is
stopped and the interrupt program is executed.                       Calendar/Clock

Quick-response Input Function                                        The built-in clock (accuracy within 1 minute/month) can be read
                                                                     from the program to show the current year, month, day, day of the
There are four inputs used for quick-response inputs (shared with    week, and time. The clock can be set from a programming device
interrupt inputs and interrupt inputs in counter mode) that can      (such as a Programming Console) or the time can be adjusted by
reliably read input signals with a signal width as short as 50 s.
Quick-response inputs are received into an internal buffer, so       rounding up or down to the nearest minute.
signals that change status within a cycle can be processed.
                                                                     Long-term Timer
Stabilizing Input Filter Function
                                                                     The long-term timer provides an easy way to control equipment
The input time constant for all inputs can be set to 1 ms, 2 ms,     scheduling. Use two instructions to set this up. The long-term
3 ms, 5 ms, 10 ms, 20 ms, 40 ms, or 80 ms. The effects of            timer instruction (TIML) lets you set values up to 99,990 seconds
chattering and external noise can be reduced by increasing the       (27 hours, 46 minutes, 30 seconds) and the Seconds-to-Hours
input time constant.                                                 conversion instruction (HMS) lets you schedule this with other
                                                                     clock functions.
Interval Timer Interrupts

The interval timer offers a 0.5 and 319,968 ms range and can be
set to generate just one interrupt (one-shot mode) or periodic
interrupts (scheduled interrupt mode) to match the application.

Communications

J NT LINK FOR PROGRAMMABLE TERMINALS

The CPM2A can be connected directly to an OMRON NT-Series Programmable Terminal in NT Link mode (1:1) for high-speed transmis-
sion of data. No separate drivers are required Use the RS-232C port for the NT Link connection.

Serial Port                                                          CBL-804*

    Peripheral
    Port

                                                                     CBL-803*                     Operator Interface
                                                                     C200H-CN_0-EU,               Terminal
                                                                     NT31C-CN_0-EU,

                                                                     (for NT31C Port B only)

                                                                     * Available in Canada only.

                                                                     Micro Programmable Controller CPM2A A--67
J HOST LINK

A Host Link connection can be made through the CPM2A's RS-232C port or Peripheral port. A personal computer or Programmable Ter-
minal connected in Host Link mode can be used for operations such as reading/writing data in the CPM2A's I/O memory or reading/chan-
ging the controller's operating mode.

1:1 Host Link Communications                                                       1:N Host Link Communications

                                                      Peripheral port connection*                        Computer with
                                                                                                        RS-422/RS-485

Responses                           CPM2A using
                                         Commandsdirect RS-232C
                                   port connection.
                                                                  Responses
                                                                                                                                   CommandsCPM1-CIF01*

                                                                                   CPM1-CIF11*

*Optional communications adapter                                                                                                             CPM2A
  converts the Peripheral port to                                                                                                (RS-232C port connection)
                RS-232C.
                                                                                   *Optional communications adapter converts the
                                                                                    Peripheral Port to RS-422/RS-485. (Up to 32
                                                                                               CPM2As can be connected.)

No-Protocol Communications

The transmit TXD (48) and receive RXD (47) instructions can be used in No-Protocol mode to exchange data with standard serial de-
vices. For example, data can be received from a bar code reader or transmitted to a serial modem. The serial devices can be connected
directly to the RS-232C port or the Peripheral port using the CPM1-CIF01 serial communications adapter.

Inputting data from a bar                                                          Outputting data to a
        code reader                                                                    serial modem

Bar code reader                                                                    Serial modem

                                                                                                                                             *An RS-232C Adapter is needed
                                                                                                                                             to connect to the Peripheral port.

                                        CPM2A                                                                         CPM2A
                           (RS-232C port connection*)                                                    (RS-232C port connection*)

J 1:1 DATA LINKS

A CPM2A can be linked directly to another CPM2A, CQM1H, CPM1, CPM1A, CPM2C, SRM1(-V2), or a C200HS or C200HX/HG/HE
programmable controller. The 1:1 PLC Link allows automatic data link connections or sharing of memory between two Omron CPUs. The
controller must be connected through the RS-232C port; it cannot be connected through the Peripheral port.

Example of a 1:1 Link between CPM2As

Master                               Slave                                                     LR 00      Link bits                         Link bits      LR 00
                                                                                   WRITE                 WRITE area                          READ area                 READ
    CPM2A                              CPM2A                                                             READ area                           WRITE area
(RS-232C port                      (RS-232C port                                                LR 07                                                       LR 07
                                                                                                LR 08                                                       LR 08
  connection)                        connection)
                                                                                   READ                                                                                WRITE

                                                                                                LR 15                                                       LR 15

A--68 Micro Programmable Controller CPM2A
J PROGRAM TRANSFER UNIT

Use Omron's EEPROM program transfer unit to update programs in machines or program multiple controllers with the same program.
The CPM1-EMU01-V1 Expansion Memory Unit connects to the peripheral port of micro and small PLCs.

                           Uploading

                                    Downloading

EEPROM  Omron SRM1, CPM1A, CPM2A,
         CPM2B, CPM2C and CQM1H
             programmable controllers

        Micro Programmable Controller CPM2A A--69
&HUWDLQ 7HUPV DQG &RQGLWLRQV RI 6DOH

2IIHU $FFHSWDQFH 7KHVH WHUPV DQG FRQGLWLRQV WKHVH 7HUPV DUH GHHPHG                          :DUUDQWLHV D ([FOXVLYH :DUUDQW\ 6HOOHU
V H[FOXVLYH ZDUUDQW\ LV WKDW WKH
     SDUW RI DOO FDWDORJV PDQXDOV RU RWKHU GRFXPHQWV ZKHWKHU HOHFWURQLF RU LQ ZULW                 *RRGV ZLOO EH IUHH IURP GHIHFWV LQ PDWHULDOV DQG ZRUNPDQVKLS IRU D SHULRG RI
     LQJ UHODWLQJ WR WKH VDOH RI JRRGV RU VHUYLFHV FROOHFWLYHO\ WKH *RRGV E\                     WZHOYH PRQWKV IURP WKH GDWH RI VDOH E\ 6HOOHU RU VXFK RWKHU SHULRG H[SUHVVHG
     2PURQ (OHFWURQLFV //& DQG LWV VXEVLGLDU\ FRPSDQLHV  6HOOHU 6HOOHU KHUHE\                    LQ ZULWLQJ E\ 6HOOHU 6HOOHU GLVFODLPV DOO RWKHU ZDUUDQWLHV H[SUHVV RU LPSOLHG
     REMHFWV WR DQ\ WHUPV RU FRQGLWLRQV SURSRVHG LQ %X\HU
V SXUFKDVH RUGHU RU RWKHU                E /LPLWDWLRQV 6(//(5 0$.(6 12 :$55$17< 25 5(35(6(17$7,21
     GRFXPHQWV ZKLFK DUH LQFRQVLVWHQW ZLWK RU LQ DGGLWLRQ WR WKHVH 7HUPV 3OHDVH                    (;35(66 25 ,03/,(' $%287 121,1)5,1*(0(17 0(5&+$17$%,/
     FRQWDFW \RXU 2PURQ UHSUHVHQWDWLYH WR FRQILUP DQ\ DGGLWLRQDO WHUPV IRU VDOHV                   ,7< 25 ),71(66 )25 $ 3$57,&8/$5 385326( 2) 7+( *22'6
     IURP \RXU 2PURQ FRPSDQ\                                                                       %8<(5 $&.12:/('*(6 7+$7 ,7 $/21( +$6 '(7(50,1(' 7+$7 7+(
                                                                                                   *22'6 :,// 68,7$%/< 0((7 7+( 5(48,5(0(176 2) 7+(,5
3ULFHV $OO SULFHV VWDWHG DUH FXUUHQW VXEMHFW WR FKDQJH ZLWKRXW QRWLFH E\                          ,17(1'(' 86( 6HOOHU IXUWKHU GLVFODLPV DOO ZDUUDQWLHV DQG UHVSRQVLELOLW\ RI
     6HOOHU %X\HU DJUHHV WR SD\ WKH SULFH LQ HIIHFW DW WLPH RI VKLSPHQW                            DQ\ W\SH IRU FODLPV RU H[SHQVHV EDVHG RQ LQIULQJHPHQW E\ WKH *RRGV RU RWKHU
                                                                                                   ZLVH RI DQ\ LQWHOOHFWXDO SURSHUW\ ULJKW F %X\HU 5HPHG\ 6HOOHU
V VROH REOLJD
'LVFRXQWV &DVK GLVFRXQWV LI DQ\ ZLOO DSSO\ RQO\ RQ WKH QHW DPRXQW RI                              WLRQ KHUHXQGHU VKDOO EH WR UHSODFH LQ WKH IRUP RULJLQDOO\ VKLSSHG ZLWK %X\HU
     LQYRLFHV VHQW WR %X\HU DIWHU GHGXFWLQJ WUDQVSRUWDWLRQ FKDUJHV WD[HV DQG                       UHVSRQVLEOH IRU ODERU FKDUJHV IRU UHPRYDO RU UHSODFHPHQW WKHUHRI WKH QRQ
     GXWLHV DQG ZLOO EH DOORZHG RQO\ LI L WKH LQYRLFH LV SDLG DFFRUGLQJ WR 6HOOHU
V               FRPSO\LQJ *RRG RU DW 6HOOHU
V HOHFWLRQ WR UHSD\ RU FUHGLW %X\HU DQ DPRXQW
     SD\PHQW WHUPV DQG LL %X\HU KDV QR SDVW GXH DPRXQWV RZLQJ WR 6HOOHU                           HTXDO WR WKH SXUFKDVH SULFH RI WKH *RRG SURYLGHG WKDW LQ QR HYHQW VKDOO 6HOOHU
                                                                                                   EH UHVSRQVLEOH IRU ZDUUDQW\ UHSDLU LQGHPQLW\ RU DQ\ RWKHU FODLPV RU H[SHQVHV
2UGHUV 6HOOHU ZLOO DFFHSW QR RUGHU OHVV WKDQ  QHW ELOOLQJ                                         UHJDUGLQJ WKH *RRGV XQOHVV 6HOOHU
V DQDO\VLV FRQILUPV WKDW WKH *RRGV ZHUH
*RYHUQPHQWDO $SSURYDOV %X\HU VKDOO EH UHVSRQVLEOH IRU DQG VKDOO EHDU DOO                          SURSHUO\ KDQGOHG VWRUHG LQVWDOOHG DQG PDLQWDLQHG DQG QRW VXEMHFW WR FRQWDPL
                                                                                                   QDWLRQ DEXVH PLVXVH RU LQDSSURSULDWH PRGLILFDWLRQ 5HWXUQ RI DQ\ JRRGV E\
     FRVWV LQYROYHG LQ REWDLQLQJ DQ\ JRYHUQPHQW DSSURYDOV UHTXLUHG IRU WKH LPSRU                   %X\HU PXVW EH DSSURYHG LQ ZULWLQJ E\ 6HOOHU EHIRUH VKLSPHQW 6HOOHU VKDOO QRW
     WDWLRQ RU VDOH RI WKH *RRGV                                                                   EH OLDEOH IRU WKH VXLWDELOLW\ RU XQVXLWDELOLW\ RU WKH UHVXOWV IURP WKH XVH RI *RRGV
7D[HV $OO WD[HV GXWLHV DQG RWKHU JRYHUQPHQWDO FKDUJHV RWKHU WKDQ JHQHUDO                          LQ FRPELQDWLRQ ZLWK DQ\ HOHFWULFDO RU HOHFWURQLF FRPSRQHQWV FLUFXLWV V\VWHP
     UHDO SURSHUW\ DQG LQFRPH WD[HV LQFOXGLQJ DQ\ LQWHUHVW RU SHQDOWLHV WKHUHRQ                   DVVHPEOLHV RU DQ\ RWKHU PDWHULDOV RU VXEVWDQFHV RU HQYLURQPHQWV $Q\
     LPSRVHG GLUHFWO\ RU LQGLUHFWO\ RQ 6HOOHU RU UHTXLUHG WR EH FROOHFWHG GLUHFWO\ RU              DGYLFH UHFRPPHQGDWLRQV RU LQIRUPDWLRQ JLYHQ RUDOO\ RU LQ ZULWLQJ DUH QRW WR EH
     LQGLUHFWO\ E\ 6HOOHU IRU WKH PDQXIDFWXUH SURGXFWLRQ VDOH GHOLYHU\ LPSRUWDWLRQ                 FRQVWUXHG DV DQ DPHQGPHQW RU DGGLWLRQ WR WKH DERYH ZDUUDQW\
     FRQVXPSWLRQ RU XVH RI WKH *RRGV VROG KHUHXQGHU LQFOXGLQJ FXVWRPV GXWLHV
     DQG VDOHV H[FLVH XVH WXUQRYHU DQG OLFHQVH WD[HV VKDOO EH FKDUJHG WR DQG                  'DPDJH /LPLWV (WF 6(//(5 6+$// 127 %( /,$%/( )25 63(&,$/ ,1',
     UHPLWWHG E\ %X\HU WR 6HOOHU                                                                   5(&7 25 &216(48(17,$/ '$0$*(6 /266 2) 352),76 25 352
)LQDQFLDO ,I WKH ILQDQFLDO SRVLWLRQ RI %X\HU DW DQ\ WLPH EHFRPHV XQVDWLVIDFWRU\                   '8&7,21 25 &200(5&,$/ /266 ,1 $1< :$< &211(&7(' :,7+ 7+(
     WR 6HOOHU 6HOOHU UHVHUYHV WKH ULJKW WR VWRS VKLSPHQWV RU UHTXLUH VDWLVIDFWRU\                 *22'6 :+(7+(5 68&+ &/$,0 ,6 %$6(' ,1 &2175$&7 :$55$17<
     VHFXULW\ RU SD\PHQW LQ DGYDQFH ,I %X\HU IDLOV WR PDNH SD\PHQW RU RWKHUZLVH                    1(*/,*(1&( 25 675,&7 /,$%,/,7< )XUWKHU LQ QR HYHQW VKDOO OLDELOLW\ RI
     FRPSO\ ZLWK WKHVH 7HUPV RU DQ\ UHODWHG DJUHHPHQW 6HOOHU PD\ ZLWKRXW OLDELOLW\                 6HOOHU H[FHHG WKH LQGLYLGXDO SULFH RI WKH *RRG RQ ZKLFK OLDELOLW\ LV DVVHUWHG
     DQG LQ DGGLWLRQ WR RWKHU UHPHGLHV FDQFHO DQ\ XQVKLSSHG SRUWLRQ RI *RRGV VROG
     KHUHXQGHU DQG VWRS DQ\ *RRGV LQ WUDQVLW XQWLO %X\HU SD\V DOO DPRXQWV LQFOXG               ,QGHPQLWLHV %X\HU VKDOO LQGHPQLI\ DQG KROG KDUPOHVV 6HOOHU LWV DIILOLDWHV DQG
     LQJ DPRXQWV SD\DEOH KHUHXQGHU ZKHWKHU RU QRW WKHQ GXH ZKLFK DUH RZLQJ WR LW                   LWV HPSOR\HHV IURP DQG DJDLQVW DOO OLDELOLWLHV ORVVHV FODLPV FRVWV DQG
     E\ %X\HU %X\HU VKDOO LQ DQ\ HYHQW UHPDLQ OLDEOH IRU DOO XQSDLG DFFRXQWV                       H[SHQVHV LQFOXGLQJ DWWRUQH\
V IHHV DQG H[SHQVHV UHODWHG WR DQ\ FODLP LQYHV
&DQFHOODWLRQ (WF 2UGHUV DUH QRW VXEMHFW WR UHVFKHGXOLQJ RU FDQFHOODWLRQ                           WLJDWLRQ OLWLJDWLRQ RU SURFHHGLQJ ZKHWKHU RU QRW 6HOOHU LV D SDUW\ ZKLFK DULVHV
     XQOHVV %X\HU LQGHPQLILHV 6HOOHU IXOO\ DJDLQVW DOO FRVWV RU H[SHQVHV DULVLQJ LQ                RU LV DOOHJHG WR DULVH IURP %X\HU
V DFWV RU RPLVVLRQV XQGHU WKHVH 7HUPV RU LQ
     FRQQHFWLRQ WKHUHZLWK                                                                          DQ\ ZD\ ZLWK UHVSHFW WR WKH *RRGV :LWKRXW OLPLWLQJ WKH IRUHJRLQJ %X\HU DW
)RUFH 0DMHXUH 6HOOHU VKDOO QRW EH OLDEOH IRU DQ\ GHOD\ RU IDLOXUH LQ GHOLYHU\                     LWV RZQ H[SHQVH VKDOO LQGHPQLI\ DQG KROG KDUPOHVV 6HOOHU DQG GHIHQG RU VHWWOH
     UHVXOWLQJ IURP FDXVHV EH\RQG LWV FRQWURO LQFOXGLQJ HDUWKTXDNHV ILUHV IORRGV                   DQ\ DFWLRQ EURXJKW DJDLQVW 6HOOHU WR WKH H[WHQW WKDW LW LV EDVHG RQ D FODLP WKDW
     VWULNHV RU RWKHU ODERU GLVSXWHV VKRUWDJH RI ODERU RU PDWHULDOV DFFLGHQWV WR                   DQ\ *RRG PDGH WR %X\HU VSHFLILFDWLRQV LQIULQJHG LQWHOOHFWXDO SURSHUW\ ULJKWV RI
     PDFKLQHU\ DFWV RI VDERWDJH ULRWV GHOD\ LQ RU ODFN RI WUDQVSRUWDWLRQ RU WKH                    DQRWKHU SDUW\
     UHTXLUHPHQWV RI DQ\ JRYHUQPHQW DXWKRULW\
6KLSSLQJ 'HOLYHU\ 8QOHVV RWKHUZLVH H[SUHVVO\ DJUHHG LQ ZULWLQJ E\ 6HOOHU                      3URSHUW\ &RQILGHQWLDOLW\ 7KH LQWHOOHFWXDO SURSHUW\ HPERGLHG LQ WKH *RRGV LV
     D 6KLSPHQWV VKDOO EH E\ D FDUULHU VHOHFWHG E\ 6HOOHU                                          WKH H[FOXVLYH SURSHUW\ RI 6HOOHU DQG LWV DIILOLDWHV DQG %X\HU VKDOO QRW DWWHPSW WR
     E 6XFK FDUULHU VKDOO DFW DV WKH DJHQW RI %X\HU DQG GHOLYHU\ WR VXFK FDUULHU                   GXSOLFDWH LW LQ DQ\ ZD\ ZLWKRXW WKH ZULWWHQ SHUPLVVLRQ RI 6HOOHU 1RWZLWKVWDQG
                                                                                                   LQJ DQ\ FKDUJHV WR %X\HU IRU HQJLQHHULQJ RU WRROLQJ DOO HQJLQHHULQJ DQG WRROLQJ
         VKDOO FRQVWLWXWH GHOLYHU\ WR %X\HU                                                        VKDOO UHPDLQ WKH H[FOXVLYH SURSHUW\ RI 6HOOHU $OO LQIRUPDWLRQ DQG PDWHULDOV
     F $OO VDOHV DQG VKLSPHQWV RI *RRGV VKDOO EH )2% VKLSSLQJ SRLQW XQOHVV RWK                     VXSSOLHG E\ 6HOOHU WR %X\HU UHODWLQJ WR WKH *RRGV DUH FRQILGHQWLDO DQG SURSUL
                                                                                                   HWDU\ DQG %X\HU VKDOO OLPLW GLVWULEXWLRQ WKHUHRI WR LWV WUXVWHG HPSOR\HHV DQG
         HUZLVH VWDWHG LQ ZULWLQJ E\ 6HOOHU DW ZKLFK SRLQW WLWOH WR DQG DOO ULVN RI ORVV RI       VWULFWO\ SUHYHQW GLVFORVXUH WR DQ\ WKLUG SDUW\
         WKH *RRGV VKDOO SDVV IURP 6HOOHU WR %X\HU SURYLGHG WKDW 6HOOHU VKDOO UHWDLQ D
         VHFXULW\ LQWHUHVW LQ WKH *RRGV XQWLO WKH IXOO SXUFKDVH SULFH LV SDLG E\ %X\HU         0LVFHOODQHRXV D :DLYHU 1R IDLOXUH RU GHOD\ E\ 6HOOHU LQ H[HUFLVLQJ DQ\ ULJKW
     G 'HOLYHU\ DQG VKLSSLQJ GDWHV DUH HVWLPDWHV RQO\                                              DQG QR FRXUVH RI GHDOLQJ EHWZHHQ %X\HU DQG 6HOOHU VKDOO RSHUDWH DV D ZDLYHU
     H 6HOOHU ZLOO SDFNDJH *RRGV DV LW GHHPV SURSHU IRU SURWHFWLRQ DJDLQVW QRUPDO                  RI ULJKWV E\ 6HOOHU E $VVLJQPHQW %X\HU PD\ QRW DVVLJQ LWV ULJKWV KHUHXQGHU
         KDQGOLQJ DQG H[WUD FKDUJHV DSSO\ WR VSHFLDO FRQGLWLRQV                                    ZLWKRXW 6HOOHU
V ZULWWHQ FRQVHQW F $PHQGPHQW 7KHVH 7HUPV FRQVWLWXWH WKH
&ODLPV $Q\ FODLP E\ %X\HU DJDLQVW 6HOOHU IRU VKRUWDJH RU GDPDJH WR WKH                            HQWLUH DJUHHPHQW EHWZHHQ %X\HU DQG 6HOOHU UHODWLQJ WR WKH *RRGV DQG QR SUR
     *RRGV RFFXUULQJ EHIRUH GHOLYHU\ WR WKH FDUULHU PXVW EH SUHVHQWHG LQ ZULWLQJ WR                YLVLRQ PD\ EH FKDQJHG RU ZDLYHG XQOHVV LQ ZULWLQJ VLJQHG E\ WKH SDUWLHV
     6HOOHU ZLWKLQ  GD\V RI UHFHLSW RI VKLSPHQW DQG LQFOXGH WKH RULJLQDO WUDQVSRUWD                G 6HYHUDELOLW\ ,I DQ\ SURYLVLRQ KHUHRI LV UHQGHUHG LQHIIHFWLYH RU LQYDOLG VXFK
     WLRQ ELOO VLJQHG E\ WKH FDUULHU QRWLQJ WKDW WKH FDUULHU UHFHLYHG WKH *RRGV IURP               SURYLVLRQ VKDOO QRW LQYDOLGDWH DQ\ RWKHU SURYLVLRQ H 6HWRII %X\HU VKDOO KDYH
     6HOOHU LQ WKH FRQGLWLRQ FODLPHG                                                               QR ULJKW WR VHW RII DQ\ DPRXQWV DJDLQVW WKH DPRXQW RZLQJ LQ UHVSHFW RI WKLV
                                                                                                   LQYRLFH I $V XVHG KHUHLQ LQFOXGLQJ PHDQV LQFOXGLQJ ZLWKRXW OLPLWDWLRQ

&HUWDLQ 3UHFDXWLRQV RQ 6SHFLILFDWLRQV DQG 8VH

6XLWDELOLW\ RI 8VH 6HOOHU VKDOO QRW EH UHVSRQVLEOH IRU FRQIRUPLW\ ZLWK DQ\ VWDQ               3URJUDPPDEOH 3URGXFWV 6HOOHU VKDOO QRW EH UHVSRQVLEOH IRU WKH XVHU
V SUR
     GDUGV FRGHV RU UHJXODWLRQV ZKLFK DSSO\ WR WKH FRPELQDWLRQ RI WKH *RRG LQ WKH                  JUDPPLQJ RI D SURJUDPPDEOH *RRG RU DQ\ FRQVHTXHQFH WKHUHRI
     %X\HU
V DSSOLFDWLRQ RU XVH RI WKH *RRG $W %X\HU
V UHTXHVW 6HOOHU ZLOO SURYLGH
     DSSOLFDEOH WKLUG SDUW\ FHUWLILFDWLRQ GRFXPHQWV LGHQWLI\LQJ UDWLQJV DQG OLPLWDWLRQV        3HUIRUPDQFH 'DWD 3HUIRUPDQFH GDWD JLYHQ LQ WKLV FDWDORJ LV SURYLGHG DV D
     RI XVH ZKLFK DSSO\ WR WKH *RRG 7KLV LQIRUPDWLRQ E\ LWVHOI LV QRW VXIILFLHQW IRU D             JXLGH IRU WKH XVHU LQ GHWHUPLQLQJ VXLWDELOLW\ DQG GRHV QRW FRQVWLWXWH D ZDUUDQW\
     FRPSOHWH GHWHUPLQDWLRQ RI WKH VXLWDELOLW\ RI WKH *RRG LQ FRPELQDWLRQ ZLWK WKH                 ,W PD\ UHSUHVHQW WKH UHVXOW RI 6HOOHU
V WHVW FRQGLWLRQV DQG WKH XVHU PXVW FRUUH
     HQG SURGXFW PDFKLQH V\VWHP RU RWKHU DSSOLFDWLRQ RU XVH 7KH IROORZLQJ DUH                      ODWH LW WR DFWXDO DSSOLFDWLRQ UHTXLUHPHQWV $FWXDO SHUIRUPDQFH LV VXEMHFW WR WKH
     VRPH H[DPSOHV RI DSSOLFDWLRQV IRU ZKLFK SDUWLFXODU DWWHQWLRQ PXVW EH JLYHQ                    6HOOHU
V :DUUDQW\ DQG /LPLWDWLRQV RI /LDELOLW\
     7KLV LV QRW LQWHQGHG WR EH DQ H[KDXVWLYH OLVW RI DOO SRVVLEOH XVHV RI WKLV *RRG
     QRU LV LW LQWHQGHG WR LPSO\ WKDW WKH XVHV OLVWHG PD\ EH VXLWDEOH IRU WKLV *RRG            &KDQJH LQ 6SHFLILFDWLRQV 3URGXFW VSHFLILFDWLRQV DQG DFFHVVRULHV PD\ EH
     L 2XWGRRU XVH XVHV LQYROYLQJ SRWHQWLDO FKHPLFDO FRQWDPLQDWLRQ RU HOHFWULFDO                  FKDQJHG DW DQ\ WLPH EDVHG RQ LPSURYHPHQWV DQG RWKHU UHDVRQV ,W LV RXU SUDF
          LQWHUIHUHQFH RU FRQGLWLRQV RU XVHV QRW GHVFULEHG LQ WKLV GRFXPHQW                        WLFH WR FKDQJH SDUW QXPEHUV ZKHQ SXEOLVKHG UDWLQJV RU IHDWXUHV DUH FKDQJHG
     LL (QHUJ\ FRQWURO V\VWHPV FRPEXVWLRQ V\VWHPV UDLOURDG V\VWHPV DYLDWLRQ                       RU ZKHQ VLJQLILFDQW FRQVWUXFWLRQ FKDQJHV DUH PDGH +RZHYHU VRPH VSHFLILFD
          V\VWHPV PHGLFDO HTXLSPHQW DPXVHPHQW PDFKLQHV YHKLFOHV VDIHW\                             WLRQV RI WKH *RRG PD\ EH FKDQJHG ZLWKRXW DQ\ QRWLFH :KHQ LQ GRXEW VSHFLDO
          HTXLSPHQW DQG LQVWDOODWLRQV VXEMHFW WR VHSDUDWH LQGXVWU\ RU JRYHUQPHQW                   SDUW QXPEHUV PD\ EH DVVLJQHG WR IL[ RU HVWDEOLVK NH\ VSHFLILFDWLRQV IRU \RXU
          UHJXODWLRQV                                                                              DSSOLFDWLRQ 3OHDVH FRQVXOW ZLWK \RXU 6HOOHU
V UHSUHVHQWDWLYH DW DQ\ WLPH WR
     LLL 6\VWHPV PDFKLQHV DQG HTXLSPHQW WKDW FRXOG SUHVHQW D ULVN WR OLIH RU                      FRQILUP DFWXDO VSHFLILFDWLRQV RI SXUFKDVHG *RRG
          SURSHUW\ 3OHDVH NQRZ DQG REVHUYH DOO SURKLELWLRQV RI XVH DSSOLFDEOH WR
          WKLV *RRG                                                                            (UURUV DQG 2PLVVLRQV 7KH LQIRUPDWLRQ LQ WKLV FDWDORJ KDV EHHQ FDUHIXOO\
     1(9(5 86( 7+( 352'8&7 )25 $1 $33/,&$7,21 ,192/9,1* 6(5,286                                    FKHFNHG DQG LV EHOLHYHG WR EH DFFXUDWH KRZHYHU QR UHVSRQVLELOLW\ LV DVVXPHG
     5,6. 72 /,)( 25 3523(57< :,7+287 (1685,1* 7+$7 7+( 6<67(0                                     IRU FOHULFDO W\SRJUDSKLFDO RU SURRIUHDGLQJ HUURUV RU RPLVVLRQV
     $6 $ :+2/( +$6 %((1 '(6,*1(' 72 $''5(66 7+( 5,6.6 $1' 7+$7
     7+( 6(//(5
6 352'8&7 ,6 3523(5/< 5$7(' $1' ,167$//(' )25
     7+( ,17(1'(' 86( :,7+,1 7+( 29(5$// (48,30(17 25 6<67(0
    &RPSOHWH 7HUPV DQG &RQGLWLRQV RI 6DOH IRU SURGXFW SXUFKDVH DQG XVH DUH RQ 2PURQV ZHEVLWH
    DW ZZZRPURQFRPRHL XQGHU WKH $ERXW 8V WDE LQ WKH /HJDO 0DWWHUV VHFWLRQ

$// ',0(16,216 6+2:1 $5( ,1 0,//,0(7(56

7R FRQYHUW PLOOLPHWHUV LQWR LQFKHV PXOWLSO\ E\  7R FRQYHUW JUDPV LQWR RXQFHV PXOWLSO\ E\

20521 (/(&7521,&6 //&                        20521 &$1$'$ ,1&      20521 21/,1(

2QH &RPPHUFH 'ULYH                            0LOQHU $YHQXH        *OREDO  KWWSZZZRPURQFRP
6FKDXPEXUJ ,/                                7RURQWR 2QWDULR 0% 9  86$  KWWSZZZRPURQFRPRHL
                                                                   &DQDGD  KWWSZZZRPURQFD
                                             

)RU 86 WHFKQLFDO VXSSRUW RU RWKHU LQTXLULHV



Cat. No. R301-E3-01  2/04                    Specifications subject to change without notice  Printed in USA
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved