电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

CONNECTOR FOR K3TE

器件型号:CONNECTOR FOR K3TE
器件类别:热门应用    机电/工控/自动化   
文件大小:1869.7KB,共7页
厂商名称:All Sensors
下载文档

器件描述

控制器 connector for k3te

参数
制造商: Omron
产品种类: 控制器
RoHS:

CONNECTOR FOR K3TE器件文档内容

Digital Panel Meter

K3TE

Easy-to-use, Low-cost Digital Panel Meter
that Accepts DC Input

Compact DIN-size (96 x 48 (W x H)) body.
Mounting thickness of only 3.5 mm required.
Highly visible display with 14.2-mm-high LEDs.
Easy-to-mount snap-in construction.
Conforms to EMC standards EN61010-1 (IEC61010-1).

Model Number Structure

Model Number Legend      3. Series No.
                             1: Current series
K3TE -
                          4. Supply Voltage
                 1 2 34
                             4: 100 to 120 VAC
1, 2. Input Code             5: 200 to 240 VAC
                             6: 24 VDC (internally insulated)
       V1: 199.9 mV
       V2: 1.999 V
       V3: 19.99 V
       V4: 199.9 V
       A1: 199.9 A
       A2: 1.999 mA
       A3: 19.99 mA
       A4: 199.9 mA
       A5: 1.999 A

http://www.ia.omron.com/                             (c)Copyright OMRON Corporation 2007 All Rights Reserved.  1
                                                                                                        K3TE

Ordering Information

List of Models

Range       Measuring ranges                                   Supply voltage
                                                               200 to 240 VAC
                                  100 to 120 VAC                                          24 VDC
                                                                                (internally insulated)
DC voltage  199.9 mV             K3TE-V114                    K3TE-V115       K3TE-V116
DC current  1.999 V              K3TE-V214                    K3TE-V215       K3TE-V216
            19.99 V              K3TE-V314                    K3TE-V315       K3TE-V316
            199.9 V              K3TE-V414                    K3TE-V415       K3TE-V416
            199.9 A              K3TE-A114                    K3TE-A115       K3TE-A116
            1.999 mA             K3TE-A214                    K3TE-A215       K3TE-A216
            19.99 mA             K3TE-A314                    K3TE-A315       K3TE-A316
            199.9 mA             K3TE-A414                    K3TE-A415       K3TE-A416
            1.999 mA             K3TE-A514                    K3TE-A515       K3TE-A516

Note: The K3TE-V4@@ does not conform to CE marking standards.

Accessories (Order Separately)

                      Name                   Appearance                             Model
Water-resistive Soft Front Cover                                               K32-L49SC

Water-resistive Mounting Bracket                                               K32-L49MB
Note: Be sure to use the Soft Front Cover and Mounting Bracket as a set.

            http://www.ia.omron.com/                                      (c)Copyright OMRON Corporation 2007 All Rights Reserved.  2
                                                                                                                   K3TE

Specifications

Ratings

Supply voltage                  100 to 120 VAC; 200 to 240 VAC (50/60 Hz); 24 VDC (internally insulated)
Operating voltage range
Power consumption               -15% to +10% of supply voltage
Insulation resistance
Dielectric strength             3 VA (at max. AC load); 1.3 W (at max. DC load) (see note)
Noise immunity
Vibration resistance            10 M min. (at 500 VDC) between external terminal and case
Shock resistance
Ambient temperature             AC model: 2,000 VAC min. for 1 min between input terminal and power supply
Ambient humidity                DC model: 500 VDC min. for 1 min between input terminal and power supply
Ambient operating atmosphere    AC/DC model: 2,000 VAC min. for 1 min between external terminal and case
EMC
                                AC model:       1,500 V on power supply terminals in normal or common mode
Approved standards              DC model:       480 V on power supply terminals in normal mode
                                                1,500 V on power supply terminals in common mode

                                Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in X, Y, and Z directions
                                Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions

                                Malfunction: 98 m/s2 for 3 times each in 6 directions
                                Destruction: 294 m/s2 for 3 times each in 6 directions

                                Operating:      -10 to 55C (with no icing)
                                Storage:        -20 to 65C (with no icing)

                                Operating: 35% to 85% (with no condensation)

                                No corrosive gas

                                (EMI)                             EN61326+A1  Industry

                                Emission Enclosure:               CISPR 11 Group 1 class A: CISRP16-1/-2

                                Emission AC Mains:                CISPR 11 Group 1 class A: CISRP16-1/-2

                                (EMS)                             EN61326+A1  Industry

                                Immunity ESD:                     EN61000-4-2: 4 kV contact discharge (level 2)

                                                                              8 kV air discharge (level 3)

                                Immunity RF-interference:         EN61000-4-3: 10 V/m (amplitude-modulated,

                                                                              80 MHz to 1 GHz) (level 3)

                                Immunity Fast Transient Noise: EN61000-4-4: 2 kV (power line) (level 3)

                                Immunity Burst Noise:                         1 kV line to line (I/O signal line)

                                Immunity Surge:                   EN61000-4-5: 1 kV line to line

                                                                              2 kV line to ground (power line)

                                Immunity Conducted Disturbance EN61000-4-6: 3 V (0.15 to 80 MHz) (level 2)

                                Immunity Voltage Dip/Interrupting EN61000-4-11: 0.5 cycles, 0, 180, 100% (rated voltage)

                                Conforms to EN61326+A1, EN61010-1 (IEC61010-1)
                                Conforms to VDE0106/P100 (finger protection) when the terminal cover is mounted.

Note: 1. An inrush current of approximately 0.5 A will flow at the moment the power is turned on and continued for approximately 2 ms.
        2. The K3TE-V4@@ does not conform to CE marking standards.

Characteristics

Input signal                    DC voltage/current
A/D conversion method
Sampling period                 Double integral method
Display refresh period
Max. displayed digits           2.5 times/s
Display
Decimal point display position  2.5 times/s
Sign display
Overflow/underflow display      3 1/2 digits (1999)

Zero suppression                7-segment red LED
External control
Degree of protection            By short-circuiting terminals

                                "-" is displayed automatically with a negative input signal

                                Overflow: 1@@@
                                Underflow: -1@@@

                                Not supported.

                                Process value hold (terminals on rear panel short-circuited)

                                Front panel: IEC IP51 (see note)

                                Case:        IEC IP20

                                Terminals: IEC IP00

Note: IP51 is maintained when the water-resistive soft cover and bracket are used. IP50 will be, however, maintained without these water-resistive
        accessories.

http://www.ia.omron.com/                                          (c)Copyright OMRON Corporation 2007 All Rights Reserved.                          3
Measuring Ranges                                                                                                     K3TE

Input range       Measuring range    Max. resolution          Input impedance              Accuracy          Max. permissible load
DC voltage    199.9 mV             100 V                    100 M              0.1%rdg 1 digit           250 V
              1.999 V              1 mV                     100 M              0.1%rdg 1 digit           250 V
DC current    19.99 V              10 mV                    10 M               0.1%rdg 1 digit           250 V
              199.9 V              100 mV                   10 M               0.1%rdg 1 digit           350 V
              199.9 A              100 nA                   1 k                0.1%rdg 1 digit           10 mA
              1.999 mA             1 A                      100                0.1%rdg 1 digit           50 mA
              19.99 mA             10 A                     10                 0.1%rdg 1 digit           150 mA
              199.9 mA             100 A                    1                  0.1%rdg 1 digit           500 mA
              1.999 mA             1 mA                     0.1                0.3%rdg 1 digit           3 A

Note: The above accuracy is at an ambient temperature of 235C.

Connections

External Connections                                             DC Power Supply

Connector and connector screws are provided with the model.

AC Power Supply

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18                      1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

+  -          COM HOLD  103 102 101                               +  -          COM HOLD       103 102 101

Signal input  Decimal position AC power supply                    Signal input                 Decimal position DC power supply

Note: 1. Terminals 3 and 7 of the AC and DC models are not internally insulated. Connect a relay with high contact reliability and insulation
           (with a minimum load current of 0.3 mA) or a photocoupler with high insulation (with a residual voltage of 1 V max. and a current
           leakage of 0.1 mA max.) to these terminals for external control.

        2. The terminals marked with a white rectangular box are not used. Do not use these terminals for transmission of signals.

Nomenclature

                                                                  Select the decimal position  103 102 101
                                                                  with terminal 12, 13, or 14
                                                                  on the rear panel.

              PV display                Unit name

              http://www.ia.omron.com/                                          (c)Copyright OMRON Corporation 2007 All Rights Reserved.       4
                                                                                                                                     K3TE

Dimensions                                                                                      Panel Cutouts

Note: All units are in millimeters unless otherwise indicated.                                                            92+-00.8

                                                                    92                                                                      75 min.

                                                                                     45+-00.6

                                                                                                       120 min.

                                                                                     Note: The values above are recommended

                                                                                                values. Do not group-mount the meters

                                                                                                at intervals less than the

                                              48                                 43             recommended ones.

                                                                                                LED Indicator Size

               96                                                            70

                                                                        3.5                                    14.2 mm

                                                                                                       7.8 mm

Application Examples

High DC Voltage Measurement                                                      Large DC Current Measurement

When voltage exceeding the maximum voltage in the                                When large DC current exceeding 2 A is measured, a
standard range is measured (for example: more than                               shunt is connected externally.
200 V), a divider is connected externally.

           Divider                                                                     Hi                    Hi
                                   Hi                                            Input Current
                                                                                                       Voltage
           R1                          Digital                                                         (mV)                 Digital
                                                                                                                            panel
Input  E1  R2  E2                      panel                                                                                meter

                                       meter

Lo             Lo                                                                Lo                    Lo

                                                                                                Shunt  When current range DPM is

                                       E2 = R2                                                         used, disconnect the internal
                                       E1 R1 + R2
                                                                                                       shunt resistor.

       http://www.ia.omron.com/                                                  (c)Copyright OMRON Corporation 2007 All Rights Reserved.            5
Safety Precautions                                                                                             K3TE

Mounting                                                                 Accessories (Order Separately)

Recommended panel thickness is 1 to 3.2 mm.                              Water-resistive Soft Front Cover
When mounting, insert the Digital Panel Meter in the mounting hole
and make sure that the Digital Panel Meter is secured with mounting      Before mounting the Digital Panel Meter to a panel, attach the water-
hooks.                                                                   resistive soft front cover and mounting bracket to the Digital Panel
Always attach the Mounting Bracket before wiring the terminals. Also,    Meter properly so that the Digital Panel Meter will maintain IP51
always remove the wiring before removing the Mounting Bracket.           water-resistive standards. Before you calibrate Digital Panel Meters,
Mount the Digital Panel Meter as horizontally as possible.               remove the water-resistive soft front cover. Refer to the operation
Never use the Digital Panel Meter in locations where corrosive gas       manual included with the Digital Panel Meter for the calibration pro-
(particularly sulfide or ammonia gas) is generated.                      cedure.
As much as possible avoid use of the Digital Panel Meter in a loca-
tion subject to severe shock or vibration, excessive dust, or exces-                                                                           Mounting
sive moisture.                                                                                                                                 Bracket
Select a mounting location where the Digital Panel Meter can be
used at an ambient operating temperature -10 to 55C.                                     Soft Cover
No product is shipped with the unit label attached. Select a unit label            Note: Be sure to use the Water-resistive Soft Front Cover and
from the sheet provided, and attach it to the Digital Panel Meter.
                                                                                           mounting bracket together.

Calibration

Calibrate the Digital Panel Meter regularly so that the Digital Panel
Meter can maintain processing accuracy.

Use a standard signal generator with an accuracy of 99.99% min. for
calibration.

For the precise calibration methods, refer to the Instruction Sheet for
the Digital Panel Meter.

After the front panel cover is removed to calibrate the K3TE, be sure
not to touch components other than the calibration adjustor. Keep
metal objects off the K3TE while calibrating, especially when power
is turned on.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                  In the interest of product improvement, specifications are subject to change without notice.

http://www.ia.omron.com/                                                 (c)Copyright OMRON Corporation 2007 All Rights Reserved.                        6
                                                                 Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability
WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL
LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR
STRICT LIABILITY.

In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                             Application Considerations
SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the product.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety
   equipment, and installations subject to separate industry or government regulations.

Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

                                                                        Disclaimers
CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased product.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS
The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent
the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

COPYRIGHT AND COPY PERMISSION
This catalog shall not be copied for sales or promotions without permission.

This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this
catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.

OMRON Corporation                                                                                                                                      2007. 3
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                      (c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved