CJ1G-CPU44P

器件型号:CJ1G-CPU44P
器件类别:热门应用    测试测量   
文件大小:45585.93KB,共14页
厂商名称:OMRON
厂商官网:https://www.omron.com
标准:  
下载文档

器件描述

control logic cpu44 W process

参数
Datasheets:
CJ Series:
Standard Package : 1
Category: Industrial Controls, Meters
Family: Controllers - Programmable Logic (PLC)
Series: CJ1
Number of Inputs and Type: -
Number of Outputs and Type: -
Voltage - Supply: -
Display Type: -
Status Indicator: Yes
Expandable: Yes
Communications: -
Memory Size: 64K words
Battery Backup: Yes
Response Time: -
Features: -
Operating Temperature: -
Software: CX-One
Mounting Height: 2.91" (73.9mm)
Ingress Protection: -
Approvals: CE, UC1
Mechanical Life: -
Other Names: CJ1GCPU44P

CJ1G-CPU44P器件文档内容

                                                   Read and Understand this Catalog                                                                                           Series

Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have any                              Programmable Controllers
questions or comments.
                                                                                                                                                             CJ1G-CPU P Loop-control CPU Unit
                                                  Warranty and Limitations of Liability
WARRANTY                                                                                                                                                     Unit Version 3.0 (Version Upgrade)

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or                              CJ1W-P  Process Input Units
other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,                                                                   Fully Integrated Sequence and Loop Control
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT                                                      New Built-in Loop Controller
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT,
WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS
UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND
MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                         Application Considerations
SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the
product in the customer's application or use of the product.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be
used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY
RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                    Disclaimers
CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your
OMRON representative at any time to confirm actual specifications of purchased product.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a
warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements.
Actual performance is subject to the OMRON Warranty and Limitations of Liability.

Note: Do not use this document to operate the Unit.                             Printed on 100%
                                                                                Recycled Paper

OMRON Corporation                OMRON ELECTRONICS LLC                            Authorized Distributor:
                                 1 East Commerce Drive, Schaumburg,             Note: Specifications subject to change without notice.
Control Devices Division H.Q.    IL 60173 U.S.A.
Shiokoji Horikawa, Shimogyo-ku,  Tel : (1)847-843-7900 / Fax : (1)847-843-8568
Kyoto, 600-8530 Japan

Tel: (81)75-344-7109             OMRON ASIA PACIFIC PTE. LTD.

Fax: (81)75-344-7149             83 Clemenceau Avenue,

                                 #11-01, UE Square,

Regional Headquarters            Singapore 239920

OMRON EUROPE B.V.                Tel:(65)6835-3011/Fax: (65)6835-2711

Wegalaan 67-69, NL-2132 JD Hoofddorp OMRON (CHINA) CO., LTD.

The Netherlands                  Room 2211, Bank of China Tower,

Tel:(31)2356-81-300/             200 Yin Cheng Zhong Road,

Fax : (31)2356-81-388            PuDong New Area, Shanghai, 200120 China

                                 Tel: (86)21-5037-2222/Fax: (86)21-5037-2200                                                            Cat. No. R128-E1-02
                                                                                                                                        Printed in Japan
                                                                                                                                        0106-2M
            Introducing the New Style of Loop Control

   Advanced controller functions integrated with the same CJ-series
   functionality and high-speed capabilities

                                                            Ultra-small size fits in most                                                    Super compact: Only 90 mm High and 65 mm Deep, and
                                                            devices                                                                          Backplane-free structure enables flexible width design.
                                                            Backplane-free structure provides
                                                            the functions you need in                                               Compact PLC Aids Machine Downsizing by Fitting Just About Anywhere.
                                                            minimum space.                                                          Wide Array of I/O Units, Special I/O Units, and CPU Bus Units Are Available to Suit Your Application.
                                                            Low-cost solution for controlling
                                                            multiple loops

   Function block programming for
   easy engineering
   Seamless integration of sequence
   control and loop control.
   HMI windows can be simply
   generated from function blocks
   automatically.

                                                                      Control functions have the added
                                                                      ability to control multiple loops.
                                                                      Consolidating the proven
                                                                      CS-series loop-control technology
                                                                      Effective maintenance functions

                                                                                                                                                                                                        Duct

                                                                                                                                                                                     90 mm high                                Power supply SSR  Contactor

                                                                                                                                                                   Greatly                                                     S82K  G3J         J7AN
                                                                                                                                                               reduces space
                                                                                                                                                               between ducts

                                                                                                                                                                                                        Duct

   Integrated Loop Control and Sequence Control                                                                                           High-speed sequence control functions can be used directly for
                                                                                                                                          high-speed, advanced loop control.
   An engine for controlling analog quantities (e.g., temperature, pressure, flowrate) is built into the CPU Unit together
   with the engine for executing sequence control, delivering high-speed sequence control and high-speed, advanced                  Sequence control: Executes 20-Kstep ladder programs in 1 ms (with basic instructions only).
   analog quantity control in a single Unit.

                                                                                                                                    PCMIX = 7.4 LD or OUT executed in 40 ns

                                                                                                                                    Loop control: Executes PID operations for 20 loops in up to 10 ms. This is a guide for general

   Sequence Control Engine                                            Loop Control Engine                                           applications. (See note.)

   CPU Unit element:                          69 mm                   Loop Controller Element:                              Sequencing
   CJ1G-CPU4 H                                                        Up to 300 or 50 function blocks
                                                                                                                            PCMIX Values                                             Note: Loop configuration: Ai4 Terminal + Segment Linearizer + Basic PID + Ao4 Terminal
   CX-Programmer sequence control program                             CX-Process loop control program (function blocks)                                                                      The external I/O response time in the overall system refers to the conversion time.
   (ladder, function block, structured text)
                                                                                                                            CJ1G                               7.4

                                                                                                                            SYSMAC        1.4

                                     90 mm

                                                                                                                            Dedicated microcomputer board      SYSMAC CJ-series PLC                     Digital Controller

   Execute 20-Kstep ladder                                  D: 65 mm  Execute PID Control for
   programs in 1 ms (See note.)                                       20 Loops in 10 ms (See note.)
                                              Loop-control
   Note: Basic instructions only                 CPU Unit             Note: General application (e.g., loop
                                                                      configuration: Ai4 Terminal + Segment
                                                                      Linearizer + Basic PID + Ao4 Terminal)                                                   The same level of high-speed processing  High-speed processing
                                                                                                                                                                                                        (Example: 50 ms)
                                                                                                                            High-speed processing                     Only One CPU Unit Needed
                                                                                                                            (Example: 1-ms response)

2                                                                                                                                                                                                                                                                                 3
                      Function blocks make loop-control programming easy. You can also create                                                                                                                                                                                        Simply turn the DIP Switch ON/OFF to save or read the
                      CX-Process Tool tuning windows to help adjust loops. Controller faceplates                                                                                                                                                                                     user program including function blocks using the
                      can be created automatically for touch panel displays.                                                                                                                                                                                                         Memory Card.

                   Sequence control programs: Standardize and simplify programs using structured programming. Special I/O                                                                                                                   Simple backup function enables backup, recovery, and comparison of all PLC data including the
                   Unit and CPU Bus Unit settings are easy with function blocks (using ladder programming language or                                                                                                                       function block programs for the Loop Control Board using the Memory Card.
                   structured text).                                                                                                                                                                                                        Save tag settings, comments, annotations, and connection data created using the CX-Process
                   Loop control programs: By combining function blocks, a wide array of control methods can be easily                                                                                                                       Tool to either a Memory Card or a Loop-control CPU Unit. Note: Supported by unit version 3.0 or later.
                   configured, from basic PID control used by Temperature Controllers to program, cascade, and feed-forward
                   control.

   Engineering Example: Program Control                                                                                                                                                                                                                                                                                                                CPU Unit
                                                                                                                                                                                                                                                                                                                                                                              Function
   Loop-control CPU Unit                                 CX-Process Tool (Software for Personal Computer)         Face Plate Auto-Builder for NS                                                                                            Press the                                                                                                                           block
                                                                                                                                                                                                                                            Memory Card                                                                                                                       program
         SP                                              1 Combine function blocks and connect graphically        3 Touch panel windows are automatically generated.                                                                        power supply
                                                           using the mouse.                                               NT-series PT                                                                                                      switch for 3 s.                                                                                                     Sequence
                                               Time                                                                                                                                                                                                                                                                                                              program
                                                         Analog Input            Basic PID  Analog Output                                                       Control window
                                                         Field Terminal        PV           Field Terminal                                                                                                                                                                                                                                                        I/O memory

                                                                       Y1                    X1                                                                                                                                                                                                                                                                Parameter Area

                                                         Y2                                 X2                                                                                                                                                                                                                                                         Condition: Pin 7 is ON           Memory
                                                                                                                                                                                                                                                                                                                                                                                           Card
                                                         Y3                    RSP MV       X3
                                                                                                                                                                                                                                                                                                                                                                                        Simple backup
                                                         Y4                                 X4                                                                                                                                                                                                                                                                                          to Memory
                                                                                                                                                                                                                                                                                                                                                                                        Card, including
           RSP                                                                                                                   Serial or                                                                                                                                                                                                                                              function block
                                                                                                                                 Ethernet                                                                                                                                                                                                                                               data.
       PV             TIC MV                                                                                                     communications

       Analog             Analog                         Segment               2 Adjust PID and other parameters                                         Tuning window
       Input             Output                          Program                  in the tuning window.
       Unit                                                                                                       Loop-control CPU Unit
                              Unit                                  Y1
       Input
       channel 1         Output
                      channel 1

   Temperature Heater output                                                                                      Segment program                                                                                                           Consolidating OMRON's expertise in temperature and process control
   input                                                                                                          parameter setting window                                                                                                  cultivated over many years to provide you with effortless solutions
                                                                                                                                                                                                                                            using proven algorithms.
                                                                        Lineup includes low-cost models that use up to 50 function
                                                                        blocks and models that allow up to 300 blocks designed for                                                                                                          Loop control: Proven functionality of Temperature Controllers and CS-series Loop Control
                                                                        large-scale systems and complicated operations.
                                                                                                                                                                                                                                            Boards (see note 1) in a compact size.                                                                            Conventional PID gain adjustment

                   Loop control: Programming with function blocks to suit the application.                                                                                                                                                  New Algorithm Further Enhances Control                                                                                 Longer time required
                                                                                                                                                                                                                                            Stability                                                                                                              to stabilize
                   System configuration: Choose and combine functions from a broad selection of I/O Units. Process Input                                                                                                                                                                                                       Disturbance generated
                                                                                                                                                                                                                             Units, Analog  Disturbance Overshoot Adjustment                                                                                  Using the Disturbance
                                                                                                                                                                                                                                                                                                                                                              Overshoot Adjustment function
                                                                                                                                                I/O Units, etc.                                                                             This function restrains overshoot when a disturbance is                            Disturbance
                                                                                                                                                                                                                                            generated, allowing faster stabilization.                                                                               Faster stabilization
   Read data from                   Perform PID              Perform                        Control output        System Configuration                                                                                                      [Example]                                                                                       Overshoot
    Analog Input                       control           heating/cooling                     from Analog                                                                                                                                     Temperature drops when adding objects to a furnace
         Units                                                                               Output Unit                                                                                                                                     Control disturbances when retooling
                                                              control

                                                                                                                                                                                                                                                                                                                                            Time required to
                                                                                                                                                                                                                                                                                                                                            stabilize

   Analog Input                     Basic PID            Split Conversion                   Analog Output
   Field Terminal                                                                           Field Terminal
                                    PV               SP  X1                Y1                                     Expansion Rack 10 Units max.
                  Y1                                                                          X1
                  Y2                                 DV                    Y2                 X2
                  Y3                                                                          X3
                  Y4                RSP MV                                                    X4
                  Y5                                                                          X5
                  Y6                                                                          X6                  Expansion Rack 10 Units max.  Expansion                                                                                   Optimum Tuning to Suit the Application
                  Y7                                                                          X7                                                Rack: 3
                  Y8                                                                          X8                                                Racks                                                                                       Fine Tuning
                                                                                                                                                max.
                                                                                                                                                (See note.)                                                                                 Adjust PVs, SPs, and MVs while monitoring, and save
                                                                                                                                                                                                                                            data as CSV files from the software tuning window.
   Segment                                               Bank Conversion          Switch PID                                                                                                                                                Autotuning (AT) and fine-tuning functions can also be
   Program 2                                                                   constants to SPs                                                                                                                                             used for automatically calculating PID constants (see note
                                                            X1 C_BNK                                                                                                                                                                        2).
   X1      Y1                                                         C_PID                                       Expansion Rack 10 Units max.
                                                                      C_SP
           Y2         Perform program                                 C_P
                            control                                   C_I
                                                                      C_D
                                                                      C_MH                                                                    10 Units max.                                                                                 Note 1: For details on CS-series Loop Control Boards, refer to the PLC-based       CS-Process Tool Tuning Window
                                                                      C_ML                                                                                                                                                                             Process Control Catalog (Cat. No. P051).
                                                                                                                  Note: CJ1G-CPU44P/45P
                                                                                                                  (CJ1G-CPU42P/43P: Expand up to 2 Racks)                                                                                          2: Control can be fine-tuned by automatically tuning PID parameters using
                                                                                                                                                                                                                                                       previous control parameters and three user-set requirements to execute
                                                                                                                                                                                                                                                       fuzzy logic.

4                                                                                                                                                                                                                                                                                                                                                                                                        5
   Applications                                                                                                                                                         Loop Control Machines and Product Variations

   The Loop-control CPU Unit Provides You with Solutions for the Complex and Advanced                                                                                      Model Selection
   Functions Demanded by Control Devices in an Increasingly Diverse Range of Equipment.
                                                                                                                                                                        Compact CJ-series Loop-control CPU units are ideal for equipment with built-in applications. CS-series and CS1D
                                                                                                                                                                        models designed for duplex systems are also available for processing equipment that requires high reliability.

   Sterilization and Disinfection of                                                      Industrial Furnace                                                            Processing facilities
   Pharmaceuticals, Food and Beverages                                                                                                                                  Chemical/
                                                                                                      NS-series PT
              NS-series PT                                                                                                                                               pharmaceutical
                                                                                                                                             Monitoring and operation    Utilities                                                                                        CS1D-series
                                                                   Logging Trend Data                                                         windows or heaters and    DCS replacement                                                                                  Process-control CPU Unit (See note 2.)
                                                               (monitoring and operation                                                                                 Water treatment
                                                                                                                                                temperature sensors      Etc.                                                                                              High-speed and highly reliable (duplex)
                                                                           windows)

                                                                                                                                             Loop-control CPU Unit                                                                       CS-series/CS1D-S
                                                                                                                                                                                                                                         Loop Control Board (See note 2.)
                                                                                                                                                 Cascade control of
                                                          Loop-control CPU Unit                                                                     tunnel furnace      Machinery
                                                              Program pattern                                                                                           Semi-conductor/
   Control outputs                                                   control                                                                                                                                   CJ1G-CPU4 P CJ-series
                    Pressure                                                                                                                                             electrical components                 Loop-control CPU Unit
                                     Control outputs                                                                                                                     Industrial furnaces

                               Temperature                                                                                                                               (firing)
                                                                                                                                                                         Food machines
                                                                                                                        Heater  Temperature  N2 atmosphere
                                                                                                                Workpiece       sensor         Solder                    (sterilization)
                                                                                                                                                                         Testing equipment
                                                                                          Conveyor
                                                                                                                                                                         Etc.

                                                                                                                                                                                                CJ-series
                                                                                                                                                                                                Temperature Control Unit
                                                                                                                                                                                                (See note 1.)

                                               SCR                                                                                                                      Packaging
                                            Thyristor                                                                                                                    machines

                                                                                                                                                                         General food
                                                                                                                                                                         machines

                                                                                                                                                                                               Easy                                      Controlling analog quantities

   Providing Solutions to Other Problems

   Electrical parts equipment                                                                             Fermentation equipment requiring temperature,                 Note 1: The Temperature Control Unit integrates control and I/O for either 2 loops or 4 loops.
   requiring                                                                                              pressure, flowrate, and                                                  Temperature control is achieved simply by setting parameters. (CX-Process cannot be used.)
   high-speed                                                                                             pH control.
   temperature                                                                                                                                                                 2: For details on CS-series Loop Control Boards and Process-control CPU Units, refer to the PLC-based Process Control Catalog (Cat. No. P051).
   control for                              Food machines, semi-conductor devices and
   higher precision                         other machines                                                                                                                 System Configuration Example
   and                                      requiring
   improved                                 multipoint                                                                                                                                                                      PLC
   tact time.                               temperature                                                                                                                                                                                                                                                                                       PT
                                            control.
                                                                                                                                                                        Personal computer for                                               Compensating
                                                                                                                                                                                                                                            Conductor
                                                                                                                                                                        programming/
                                                                                                                                                                                                                                                                           4 to 20 mA
                                                                                                                                                                        monitoring              4 to 20 mA     4 to       4 to           4 to 20 mA
                                                                                                                                                                                                               20 mA      20 mA                      Thermo-
                                                                                                                                                                                                                                                     couple

                                                                                                                                                                                                Sensor Flow Rate Sensor   Capacitive
                                                                                                                                                                                                                          Flow Rate Sensor
                                                                                                                                                                                                                                                     Process

   Diffusion furnaces that perform cascade                                                                                      Testing devices that frequently         Example of Peripheral Devices
   control of heater                                                                                                                                change setting
   temperatures                                                                                                                                           conditions        Temperature Sensors                               Input               Control               Output                                                                     Position Control
   and internal                                                                                                                                        and program                                                                                                                                                                                G3PX Power Controller
   chamber                                                                                                                                                   settings.     E52                                        CJ1W-P             CJ1G-CPU P           CJ1W-DA                                                                              Cycle Control
   temperatures.                                                                                                                                                           Thermocouples                              Analog Process     Loop-control         Analog Output Unit                                                                  G32A-EA + G3PA
                                                                                                                                                                           Platinum-resistance                        Input Unit         CPU Unit             (linear output)                                                                      SSR
                                                                                                                                                                           Thermometers                               CJ1W-AD                                 CJ1W-OD                                                                             G3PA/B/C, G3NA, etc.
                                                                                                                                                                                                                      Analog Input Unit                       Transistor Output Unit
                                                                                                                                                                        Analog quantities (e.g., temperature,                                                 (pulse output)                                                                      ON/OFF Control
                                                                                                                                                                        flowrate, concentration)
                                                                                                                                                                                                                                                              CJ1W-OC                                                                              Optimum Cycle Control
                                                                                                                                                                           ES1/ES1B                                                                           Relay Output Unit                                                                   G3ZA
                                                                                                                                                                           Infrared Thermosensors
                                                                                                                                                                           Flow Rate Sensors,                                                                                         RS-485 communications:                                                              7
                                                                                                                                                                           Displacement Sensors,                                                                                      Built-in serial port on CPU Unit
                                                                                                                                                                           Signal Converters, etc.                                                                                    CJ1W-SCU 1-V1

                                                                                                                                                                                                                                         SYSMAC CJ Series

6
Peripheral Devices                                                                       New Products

Input Devices                                                                            G3ZA Multi-channel Power Controller Catalog No.: J147

E52-series Temperature Controllers                                                       Multi-channel Power Controller with Zero-cross SSRs. Receives MVs from the PLC Using RS-485 Serial
                                                                                         Communications (via FB* or Protocol Macro**), and Controls the Heater Power with High Precision Using the SSR.

Plenty of Variation to Suit an Extensive Range of Applications                             Optimum Cycle Control for High-precision Control with Low Noise            Smaller than a Normal Power Controller
  Select from a variety of choices in number of elements, shape, protective              Delay control: Energy-efficient, enabling equipment downsizing by          Same height as G3PA and G3PB, enabling smaller panels and saving
  tubing length, and terminal type.                                                      using the peak current cut method, which delays the output timing          space. One Controller can control up to 8 SSRs.
  Economical models and special models are available as well as general-                 between channels.                                                          Models with 8 channels (control points) or with 4 channels and heater
  purpose models.Select from a diverse range of models to suit the application:          Control variable conversion: Enables processing and output of input        burnout detection are available.
  Models for high temperatures, metal patterns, surface measurement, and                 control quantities using the internal gradient and internal offset         RS-485 communications to set manipulated variables and heater
  room temperatures, waterproof and anti-corrosive models, models for moving             settings.                                                                  burnout detection.
  parts, and models with double elements.

   Model Structure                                                                                    PLC               Serial Communications Unit                                     Multi-channel Open-loop Heater Controller
Example: E52-CA185A D:3.2 2M
                              Element type                 Protective tubing model                                                                                                     Number of connections per communications line
                              Protective tubing length     Lead wire length                                                                                                               Multi-channel Power Controllers: 31 Units max.
                              Terminal type                                                                                                                                               Number of control channels: 124 channels (with failure
                                                                                         PMCR                                                                                             detection for all channels) or 248 channels (without
                                                                                         instruction                                                                                      failure detection for all channels).

                                                                                         or                                                                                            *Select from 4-channel and 8-channel models as required.
                                                                                                                                                                                       *Several SSRs can be connected to each channel.
ES1/ES1B-series Infrared Thermosensors                                                                RS-485
                                                                                                      (CompoWay/F)
Hygienic temperature measurement without damaging the workpiece.Ideal for
workpieces on conveyors or other applications in which contact measurement is            Control variable
difficult.                                                                               command

  ES1 Series: Designed for high-precision, small-spot, high-temperature                                    Load status
  measurements.                                                                                            monitor
  Two types of small spot: 3-mm dia. and 8-mm dia.
  High-precision and high-speed measurement with a repeatability of 0.5C
  and response speed of 0.4 s (95%).
  Models are available for medium (500 to 500C), mid-low (50 to 500C),
  and high (0 to 1000C) temperature ranges.

                                                                                                                        G3ZA                                                                       SSR

Output Devices                                                                            *: Use the CPU Unit's built-in serial port or a Serial Communications Unit to execute serial communications using FB Library objects. A CJ1W-CIF11 RS-422A Adapter is required

                                                                                               to use the CPU Unit's built-in serial port.

                                                                                         **: Use the Serial Communications Unit to execute serial communications from the Loop-control CPU Unit using a protocol macro.

G3PX-series Power Controllers                                                            Storage and Processing Unit                                                Catalog No.: V301

Single-phase Power Controller for phase control systems requiring precision              CJ1W-SPU01 SYSMAC SPU Unit
temperature control. Models with base up and soft start functions also available.
                                                                                         The SPU Unit can read the PLC's I/O memory using specific data collection methods, and record the data in CSV files.

Model Structure                                                                            Record Production Histories, Inspection Data, and Process Data                                               Explorer
                                                                                         Data can be collected by environment-resistant PLC Units, without
                              Example: G3PX-220EUN-CT03                                   using a personal computer.                                                                                             Files shared on
                                                                                         Because the Unit has a direct bus connection to the PLC and does not                                                  Windows network
   Load power supply voltage  Phase                        Current transformer types      require communications, it can collect large quantities of data at high                                           Ethernet
2: 200/220 V                                                                              speed.
                              D: Three-phase               03: 30-cm lead                Data can be collected by means of a simple settings, with no need to
   Load current                                                                           alter the ladder program.
20: 20 A                      Function classification 10: 1-m lead
40: 40 A                                                                                   Collecting Data on Equipment Operation to Analyze Errors and
60: 60 A                      UN: Single function                                          Detect Operating Trends
                                                                                         Data collection settings can be changed and collection can be
                              H: Heater burnout detection                                 restarted without stopping the PLC.
                                                                                         Files can be created in the desired data structure for only the required
                              HN: Multiple heater burnout detection                       data in the PLC.
                                                                                         Sampling Mode can be selected for high-speed, detailed sampling, or
                              C: Constant current                                         Data Storage Mode can be selected for data collection at specified
                                                                                          times or when a specified events occur.
*Three-phase Power Controllers are also available.

G3PA/B/C Power Solid-state Relay

G3PA New Power Solid-state Relay                                                                                                                                    Computer running
  Dielectric strength of 4,000 VAC with a super slim profile and built-in heat sink                                                                                 Windows
  Mount either using screws or DIN Track.
                                                                                         7-segment display              LED                                                                             SYSMAC SPU Unit
G3PB Three-phase Solid-state Relay (Contactor)                                                                          Unit number switch                                                              Memory Card
  Upgraded heat sink saves space and labor costs.                                                                                                                   Data in CPU Unit's I/O memory
  480-VAC models for a broad range of applications.

G3PC SSR with Failure Detection Function                                                 Card slot                      Card button
  Detects SSR failure, which is difficult to identify in heater temperature control,
  and outputs alarm signals simultaneously.                                                    DIP switch               COMM port                                                                                                                               Sampling_000
  Contributing to safe design and improved maintenance of heater control                                                Enter button                                                                                                                                  0.csv
  systems.                                                                               SELECT switch
                                                                                                 LAN port                                                           SYSMAC
                                                                                                                                                                    CJ-series PLC
     For details, refer to the Temperature Controllers Selection Guide (Cat. No. Y101).
                                                                                                                                                                                         High-speed, high-capacity data collection
8
                                                                                                                                                                                                                                    9
Loop-control CPU Units                                                                                Loop-control CPU Units

Loop-control CPU Units

Loop-control CPU Units

        Model                                          CPU Unit element                               Loop Controller element

CJ1G-CPU45P          I/O bit capacity  Program              Data memory capacity       Programming    Number of Programming
CJ1G-CPU44P                            capacity
CJ1G-CPU43P                                                                            software       function blocks software
CJ1G-CPU42P
                 1,280 bits (Up to 3 60 Ksteps         128 K words (DM: 32 K words, CX-Programmer, 300 blocks      CX-Process
                 Expansion Racks)                      EM: 32 K words 3 banks) CX-Simulator, etc.

                                            30 Ksteps  64 K words (DM: 32 K words,
                                                       EM: 32 K words 1 bank)
                 960 bits (Up to 2 20 Ksteps
                 Expansion Racks) 10 Ksteps                                                           50 blocks

Loop Controller Element Specifications

               Item                                                               Specification

Name                                   Loop-control CPU Unit

Model Number                           CJ1G-CPU@@P

Applicable PLCs                        CJ-series PLCs

Area for data CPU Unit's                Loop Controller element-to-CPU Unit element:
exchange Auxiliary Area                  Run Status Flag, PV Error Input Flag, MV Error Input Flag, Execution Error Flag, Function Block Data-
with CPU Unit                            base (RAM) Error Flag, Automatic Cold Start Execution Flag, Backup during Operation Flag, Function
                                         Block Changed Flag, etc.

                                        CPU Unit element-to-Loop Controller element:
                                         Start Mode at Power ON: Hot/Cold Start bit.

               User allocations in User link tables are used to allocate function block ITEM data in any part of I/O memory in the CPU Unit.

               I/O Memory              (CIO, Work, Holding, or DM Areas, or EM Area bank 0)

               Allocations for all HMI function used to allocate function block ITEM data for Control, Operation, External Controller, and

               data                    System Common blocks in the specified bank of the EM Area in the CPU Unit.

Settings                               None

Indicators                             Two LED indicators: RUN and ready

Super capacitor backup data            All function block data (including sequence tables, step ladder program commands), stored error log data

Super capacitor backup time            5 minutes at 25C

Data stored in flash memory            Function block data

Backup from RAM to flash memory Executed from CX-Process Tool (as required).

Recovery from flash memory to          Automatically transferred when power to CPU Unit is turned ON if startup mode is set for a cold start, or
RAM                                    executed from CX-Process Tool (as required).

Influence on CPU Unit cycle time 0.8 ms max. (depends on function block data contents)

Current consumption (supplied          1.06 A for 5 VDC (current consumption for Loop-control CPU Unit including CPU Unit element and Loop
from Power Supply Unit)                Controller element)

                                       Note: Increased by 150 mA when NT-AL001 Link Adapter is used.

10
Loop-control CPU Units                                                                   Loop Controller Element Specifications

Loop Controller Element Specifications

                         Item                                                            Specifications

Model                                                     CJ1G-CPU42P                         CJ1G-CPU43/44/45P

Operation method                                          Function block method

Loop Controller element                                   LCB01                               LCB03

Function    Control and     PID and other control         50 blocks max.                      300 blocks max.

block analog operation      functions, square root op-

operations blocks           eration, time operations,

                            pulse train operation, and

                            other operation functions

                            for various processes.

Sequence    Step ladder     Logic sequence and step 20 blocks max.                            200 blocks max.
control     program                                                                           4,000 commands total
            blocks          sequence functions            2,000 commands total                100 commands max. per block
                                                                                              Separable into 100 steps max.
                                                          100 commands max. per block

                                                          Separable into 100 steps max.

I/O blocks  Field terminal Analog I/O function with 30 blocks max.                            CJ1G-CPU43P: 30 blocks max.
                                                                                              CJ1G-CPU44/45P: 40 blocks max.
            blocks          Analog I/O Unit, contact

                            I/O function with Basic I/O

                            Unit

            User link ta- Analog data I/O and con- 2,400 data items max.

            bles            tact data I/O function for

                            CPU Unit

            HMI function    I/O function for the speci- Allocated 1 EM Area bank              Allocated 1 EM Area bank
                            fied bank of the EM Area Operation and Control blocks:            Operation and Control blocks:
                            in the CPU Unit for func- 50 blocks max. 20 send/receive words  300 blocks max. 20 send/receive words
                            tion block ITEM data used
                            for Control, Operation, System Common blocks:                     System Common blocks:
                            External Controller, and 20 send/receive words                    20 send/receive words
                            System Common blocks
                            for the HMI function.

            System Com- System common opera-              Single block
            mon block tion cycle setting, run/

                                 stop command, load rate
                                 monitor, etc.

Method for creating and transferring function blocks      Created using CX-Process Tool (purchased separately) and transferred to Loop
                                                          Controller.

External I/O response time                                The time from external input of analog signals up to external output of analog signals
                                                          on a single control loop depends on the function block's operation cycle and the
                                                          CPU Unit's cycle time.

Operation cycle                                           0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1, or 2 s (default: 1 s) (See note.)
                                                          Can be set for each function block.

                                                          Note: 0.01, 0.02, and 0.05 s cannot be set for some blocks.

Internal operation          Number of control loops The maximum number of loops that can be used if the LCB load rate is 80% for a
                                                                     standard applications (e.g., with each loop consisting of one Ai4 Terminal, Seg-
                                                                     ment Linearizer, Basic PID, and A04 terminal) is shown in the following table.

                                                            Operation     Maximum number Operation              Maximum number
                                                                cycle                                                  of loops
                                                                                 of loops                cycle
                                                          0.01 s                                                150 loops
                                                          0.02 s          20 loops            0.2 s             (See note.)
                                                          0.05 s
                                                          0.1 s           35 loops (see note) 0.5 s

                                                                          70 loops (see note) 1 s

                                                                          100 loops (see note) 2 s

                                                          Note: Loop Controller element LCB01: 25 loops max.

Control method              PID control method            PID with 2 degrees of freedom
Alarms
                            Control combinations          Any of the following function blocks can be combined:
                                                          Basic PID control, cascade control, feed-forward control, sample PI control, Smith
                                                          dead time compensation control, PID control with differential gap, override control,
                                                          program control, time-proportional control, etc.

                            PID block internal alarms 4 PV alarms (upper upper-limit, upper limit, lower limit, lower lower-limit) and 1
                                                                  deviation alarm per PID block

                            Alarm blocks                  High/low alarm blocks, deviation alarm blocks

                                                                                                                                          11
List of Function Blocks                                                                                             System Common Block

List of Function Blocks

System Common Block                                                Operation Blocks

   Type      Block Name                    Function                Type                 Block Name                        Function
---      System Common
                         Makes settings common to all func-        Alarm/Signal   High/Low Alarm          Provides the alarm contact outputs for the high
                         tion blocks and outputs signals for the   restrictions/  (See note.)             and low limits of single analog signals.
                         system.                                   Hold
                                                                                  Deviation Alarm         Provides the alarm contact outputs for the devia-
                                                                                  (See note.)             tion of two analog signals.

                                                                                  Rate-of-change Opera- Provides the alarm contact outputs for the high

Control Blocks                                                                    tion and Alarm          and low limits of rate-of-change operation when

                                                                                  (See note.)             the analog signal rate-of-change is output.

                                                                                  High/Low Limit          Limits the high and low limits of single analog sig-
                                                                                  (See note.)             nals.

Type     Block Name      Function                                                 Deviation Limit         Calculates the deviation between two analog sig-
                                                                                  (See note.)             nals, and limits the deviation within that range.
Controller 2-position ON/OFF 2-position type ON/OFF controller
                (See note.)                                                       Analog Signal Hold      Holds the maximum, minimum or instantaneous
                                                                                  (See note.)             value of single analog signals.

         3-position ON/OFF 3-position type ON/OFF controller for   Arithmetic     Addition or Subtraction Performs addition/subtraction with gain and bias

         (See note.)     heating/cooling ON/OFF control                           (See note.)             on up to 4 analog signals.

         Basic PID       Performs basic PID control.                              Multiplication (See note.) Performs multiplication with gain and bias on up to
         (See note.)                                                                                                 2 analog signals.

                                                                                  Division (See note.)    Performs division with gain and bias on up to 2 an-
                                                                                                          alog signals.
         Advanced PID    Performs advanced PID control for
         (See note.)     enabling deviation/MV compensation,                      Arithmetic Operation    Performs various math operation (trigonometric,
                         MV tracking, etc.                                        (See note.)             logarithmic, etc.) on floating-point decimal values
                                                                                                          converted (to industrial units) from up to 8 analog
                                                                                                          inputs.

         Blended PID     Performs PID control on the cumula-                      Range Conversion        Easily converts up to 8 analog signals simply by in-
                         tive value (cumulative deviation) be-                    (See note.)             putting the 0% and 100% input values and 0% and
                         tween the accumulated value PV and                                               100% output values.
                         accumulated value Remote Set Point.
                                                                   Functions      Square Root             Performs square root extraction (with low end cut-
                                                                                  (See note.)             out) on single analog signals.

         Batch Flowrate  Functions to open the valve at a fixed                   Absolute Value          Outputs the absolute value of single analog sig-
         Capture         opening until a fixed batch accumulat-                   (See note.)             nals.
                         ed value is reached.
                                                                                  Non-linear Gain         Performs non-linear (3 gain values) operation on
         Fuzzy Logic     Outputs up to 2 analog outputs based                     (Dead Band)             single analog signals. Analog signals can also set
                         on fuzzy logic performed on up to 8                      (See note.)             as a dead band (with different gap).
                         analog inputs.
                                                                                  Low-end Cutout          Sets output to zero close to the zero point of single
                                                                                  (See note.)             analog signals.

         Indication and Set- Manual setter with PV indication and                 Segment Linearizer      Converts single analog signals to 15 segments be-
         ting (See note.) SP setting functions                                    (See note.)             fore the signals are output.

                                                                                  Temperature and Pres-   Performs temperature and pressure correction.
                                                                                  sure Correction
         Indication and Op- Manual setter with PV indication and                  (See note.)
         eration (See note.) MV setting functions
                                                                   Time Function First-order Lag          Performs first-order lag operation on single analog
         Ratio Setting   Ratio and bias setter with PV indica-                          (See note.)       signals.
         (See note.)     tion and ratio setting function
                                                                                  Rate-of-change Limit    Performs rate-of-change restriction on single ana-
                                                                                  (See note.)             log signals.

         Indicator       PV indicator with PV alarm                               Moving Average          Performs moving average operation on single an-
         (See note.)                                                              (See note.)             alog signals.

                                                                                  Lead/Delay (See note.) Performs lead/delay operation on single analog
                                                                                                                     signals.

                                                                                  Dead Time (See note.) Performs dead time and first-order lag operations
                                                                                                                     on single analog signals.

                                                                                  Dead Time Compensa- Used for Smith's dead time compensation PID

                                                                                  tion                    control.

                                                                                  Accumulator for instanta- Accumulates analog signals, and outputs 8-digit

                                                                                  neous value input       accumulated value signals.

                                                                                  Run Time Accumulator Accumulates the operating time, and outputs the
                                                                                                                     pulse signal per specified time.

                                                                                  Time Sequence Data      Records time sequence data from analog signals
                                                                                  Statistics (See note.)  and calculates statistics, such as averages and
                                                                                                          standard deviations.

                                                                                  Ramp Program            Ramp program setter for combining ramps for time
                                                                                                          and hold values.

                                                                                  Segment Program         Segment program setter setting the output values
                                                                                                          with respect to time.

                                                                                  Segment Program 2       Segment program setting with wait function for
                                                                                                          setting the output values with respect to time.

Note: The Function Blocks dealing with high-speed operation (operation cycle: 0.01, 0.02, and 0.05 seconds is possible).

12
List of Function Blocks

                                                                                              Sequence Control

Type                  Block Name               Function                                          Type  Block Name                       Function
                                                                                              ---
Signal Selec- Rank Selector       Selects the rank of up to 8 analog signals.                          Step Ladder Pro- Performs logic sequence and step
tion/Switching (See note.)                                                                             gram (See note.) progression control.

           Input Selector (See    Selects the specified analog signals specified by
           note.)                 the contact signal from up to 8 analog signals.

           3-input Selector       Selects and outputs one of three analog input               Field Terminals
           (See note.)            signals.

           3-output Selector      Outputs one analog input signal in three switched
           (See note.)            directions.

           Constant Selector      Selects 8 preset constants by the contact signal.           Type     Block Name                       Function
           (See note.)
                                                                                              Contact  DI 8-point Termi- Inputs 8 contacts from 8-point Input
                                                                                              I/O
           Constant Generator     Outputs 8 independent constants.                            (See     nal                Unit.
           (See note.)                                                                        note.)

           Ramped Switch          Switches two analog inputs (or constants) with a                     DI 16-point Termi- Inputs 16 contacts from 16-point In-
                                  ramp.
                                                                                                       nal                put Unit.

           Bank Selector          Records the PID parameters (SP, P, I, D, MH, ML)                     DI 32-point Termi- Inputs 32 contacts from 32-point In-
                                  in up to 8 sets in advance, and switches the PID
                                  parameter for Basic/Advanced/Blended PID                             nal                put Unit.
                                  Blocks according to the analog input range
                                  (zone) or input bits.                                                DI 64-point Termi- Inputs 64 contacts from 64-point In-

           Split Converter        Inputs the MV from the Basic PID block or Ad-                        nal                put Unit.
                                  vanced PID block, converts the MV into two ana-
                                  log outputs for V characteristics or parallel                        DO 8-point Termi- Outputs 8 contacts from 8-point Out-
                                  characteristics (e.g., MV for heating or cooling)
                                  and outputs them.                                                    nal                put Unit.

Constant   Constant ITEM Setting Writes the constant to the specified ITEM at the                      DO 16-point Ter- Outputs 16 contacts from 16-point

ITEM Setting (See note.)          rising edge of the send command contact.                             minal              Output Unit.

           Variable ITEM Setting Writes the analog signal to the specified ITEM at                     DO 32-point Ter- Outputs 32 contacts from 32-point

           (See note.)            the rising edge of the send command contact.                         minal              Output Unit.

           Batch Data Collector   Stores each of max. 8 analog inputs to buffer by                     DO 64-point Ter- Outputs 64 contacts from 64-point
           (See note.)            a certain timing within sequential processing.

Pulse Train Accumulated Value In- Adds up to four accumulated value signals.                           minal              Output Unit.
Operation put Adder

           Accumulated Value Ana- Multiplies analog signals by the accumulated val-                    DI 16-point/Do16- Inputs and outputs 16 contacts each
                                                                                                       point Terminal from 16-point Input/16-point Output
           log Multiplier         ue signals.
                                                                                                                                 Units.
           Accumulator for accu- Converts 4-digit accumulated value signals to 8

           mulated value input    digits.                                                     Analog I/O AI 4-point Termi- Inputs 4 analog signals from CJ1W-

           Contact input/Accumu- Counts low-speed contact pulses, and outputs 8-              (See     nal (PTS51)        PTS51 (Isolated-type Thermocouple

           lated value output     digit accumulated signals.

           Accumulated Value In- Converts 4-digit accumulated value signals to                note.)                      Input Unit)

           put/Contact Output     low-speed contact pulses before they are output.                     AI 4-point Termi- Inputs 4 analog signals from CJ1W-

Others     Analog/Pulse Width     Changes the ON/OFF duration ratio in a constant                      nal (PTS52)        PTS52 (Isolated-type Temperature
           Converter (See note.)  cycle duration so that it is proportional to the an-
                                  alog signal.                                                                            Resistance Input Unit).

Sequence   Contact Distributor    Connect contact signals between function blocks                      AI 2-point Termi-  Inputs 2 analog signals from CJ1W-
Operation                         in a 1:1 connection.                                                 nal (PTS15/16,     PTS15 (Isolated-type Thermocouple
                                                                                                       PDC15)             Input Unit), CJ1W-PTS16 (Isolated-
           Constant Comparator    Compares up to eight sets of analog signals and                                         type Temperature Resistance Input
           (See note.)            constants, and outputs the comparison results as                                        Unit), or CJ1W-PDC15 (Isolated-
                                  contacts.                                                                               type DC Input Unit).

           Variable Comparator    Compares up to eight pairs of analog signals,
           (See note.)            and outputs the comparison results as contacts.

           Timer (See note.)      2-stage output type addition timer for forecast                      AI 8-point Termi- Inputs 8 analog signals from the
                                  values and reached values. Can also output the
                                  present value.                                                       nal (AD081)        CJ1W-AD081(-V1).

           ON/OFF Timer           Timer for performing ON-OFF operation at preset                      AO 8-point Termi- Outputs 8 analog signals from the
           (See note.)            ON and OFF times.                                                    nal (DA08V/C) CJ1W-DA08V/DA08C.

           Clock Pulse (See note.) Outputs a clock pulse at the setting time interval                  AI 4-point Termi- Inputs 4 analog signals from the
                                             for a single operation cycle.

           Counter (See note.)    2-stage output type addition timer for forecast                      nal (AD041)        CJ1W-AD041(-V1).
                                  values and arrival values. Can also output the
                                  current value.                                                       AO 4-point Termi- Outputs 4 analog signals from the

           Internal Switch        Temporary storage contact for accepting relays in                    nal (DA041)        CJ1W-DA041(-V1).
           (See note.)            the Step Ladder Program block.
                                                                                                       AO 2-point Termi- Outputs 4 analog signals from the
                                  Note: (One internal switch is already allocated
                                           as "temporary storage" in CX-Process                        nal (DA021)        CJ1W-DA021.
                                           Tool.)

           Level Check (See note.) Checks an analog input for 8 levels and outputs                     AI 4-point/AO 2-   Inputs 4 analog signals and outputs
                                             a contact corresponding to the level. The level           point Terminal     2 analog signals each from the
                                             number is also output as an analog value at the           (MAD42)            CJ1W-MAD42.
                                             same time.

Contact Type ON/OFF Valve Manipu- Manipulates and monitors ON/OFF valves with                          AI 4-point Termi- Inputs 4 analog signals from a
                                                                                                       nal (DRT1-AD04) DRT1-AD04 DeviceNet Slave Ana-
Control Target lator              open/close limit switches.
                                                                                                                                 log Input Unit.
           Motor Manipulator      Manipulates and monitors motor operation.

           Reversible Motor Manip- Manipulates and monitors reversible motor oper-                     AO 2-point Termi- Outputs two analog signals from a
                                                                                                       nal (DRT1-DA02) DRT1-DA02 DeviceNet Slave Ana-
           ulator                 ation.
                                                                                                                                 log Output Unit.
           Motor Opening Manipu- Inputs a target opening, and manipulates an

           lator                  electric positional-proportional motor.

Note: The Function Blocks dealing with high-speed operation (operation cycle: 0.01, 0.02, and 0.05 seconds is possible).

                                                                                                                                                           13
CX-Process Tool and Monitor                                                                                  Software Specifications

CX-Process Tool and Monitor

Software Specifications

                  Item                                                         Specifications

                                                            CX-Process Tool                                CX-Process Monitor Plus

Name                                     CX-Process                                                CX-Process Monitor Plus
Model number
Applicable PLCs                          WS02-LCTC1-EV5                                            WS02-LCMC1-E
Applicable Units
Compatible com-                          CS-series PLCs
puters                                   CJ-series PLCs

Communications                           CJ-series Loop-control CPU Units                          CJ-series Loop-control CPU Units
method                                   CS-series Loop Control Units/Boards                       CS-series Loop Control Units/Boards
                                         CS1D Process-control CPU Units                            CS1D Process-control CPU Units

                  Computer               IBM PC/AT or compatible

                  CPU                    Minimum:        Pentium 133 MHz min.

                                         Recommended: Celeron 400 MHz min.

                  OS                     Microsoft Windows 2000 (Service Pack 3 or higher), NT4.0 Microsoft Windows 2000, NT4.0 or XP

                                         (Service Pack 6a), 98SE, Me (See note 2), or XP

                  Memory                 Minimum:        32 Mbytes                                 Minimum:      96 Mbytes

                                         Recommended: 64 Mbytes min.                               Recommended: 128 Mbytes min.

                  Hard disk storage      Minimum:        50 Mbytes free space                      Minimum:      400 Mbytes free space

                                         Recommended: 100 Mbytes min. free space                   Recommended: 500 Mbytes min. free space

                  Monitor                Minimum: XGA                                              Minimum requirement: XGA
                                         Recommended: SXGA 65,536 colors or more                   (XGA or above recommended)

                  CD-ROM drive           1 drive min.

                  Sound board            ---                                                       1

                  Mouse                  Recommended: Microsoft mouse or compatible pointing device

                  Connection with CPU Unit When FinsGateway Serial Unit driver is used:

                  (or Serial Communica-  Communications protocol with PLC: Host Link Host Link (Peripheral Bus is not supported.) (See note 3.)
                  tions Board/Unit)       Connect the computer to the peripheral port or built-in RS-232C port of the CPU Unit, or to the

                                         RS-232C port of the Serial Communications Board/Unit.

                                          Connecting cable:
                                           For connecting to peripheral port of CPU Unit: CS1W-CN@@@ (2 m or 6 m)
                                           For connecting to RS-232C port of CPU Unit: XW2Z-@@@-@ (2 m or 5 m)

                                         When CX-Server is used:                                   CX-Server is not supported.

                                         Communications protocol with PLC: Host Link or Peripher-
                                         al Bus

                                         Connecting Cable:

                                          For connecting to peripheral port of CPU Unit:

                                         CS1W-CN@@@ (2 m or 6 m)

                                         For connecting to RS-232C port of CPU Unit:

                                         XW2Z-@@@-@ (2 m or 5 m)

                  Connection via Controller When FinsGateway Controller Link driver or CX-Server is used:

                  Link                   Install the software in a computer with a Controller Link Support Board to communicate with a PLC with a

                                         Controller Link Unit mounted.

                  Connection via Ethernet When FinsGateway ETN_UNIT driver or CX-Server is used:

                                                       Install the software in a computer with an Ethernet Board to communicate with a PLC with an Ethernet Unit
                                                       mounted.

14
CX-Process Tool and Monitor                                                                                               Connections to PLC

                           Item                                                          Specifications
Offline functions
                                 ITEM data settings for function blocks                   Construction of user screens
Online functions
                                  Software connections for analog signals

                                  Displaying and printing text strings (annotation)

                                    pasted on function block diagrams and ladder

                                    diagrams.

                                  Instructions for step ladder blocks and commands for

                                    sequence table blocks

                                  Tag settings for CX-Process Monitor

                                  Transfer of function block data (Downloading/Upload- User screens

                                    ing for Loop Control Boards/Units.)                   Overview screen

                                  Starting/stopping all function blocks (LCU/LCB)         Control screen

                                  Monitoring system operation: Monitoring and             Tuning screen

                                    controlling the System Common block (including Trend screen
                                    LCB/LCU load rates)
                                                                                           Graphic screen
                                   Validating LCB/LCU operation: Checking function
                                    block connections (including starting and starting    Operating guide message screen
                                    individual function blocks), validating ladder        System screens
                                    diagrams and sequence tables, and monitoring          Alarm history screen

                                    ITEMs                                                 System monitor screen

                                  Tuning PID constants and other parameters               Operation log screen

                                    (fine tuning and autotuning)

                                  Initialization of Loop Control Unit memory (RAM)

Note: 1. The CX-Process functions that can be used depend on the version. For details, refer to the operation manuals (Cat. No.: W372-E1-@ and
            W373-E1-@).

        2. When using Windows Me, the CPU must be a Pentium 150 MHz or higher.
        3. Peripheral Bus cannot be used when FinsGateway V3 is used.

Connections to PLC

The following 4 methods can be used to connect to a PLC.

                 Communications network                                                   Communication driver

                                                                          FinsGateway V3  FinsGateway Version             CX-Server V2.2
                                                                                            2003 (See note 1.)

Host Link                        Connection via PLC's peripheral port or  Supported (Serial Unit version is used.)        Supported
Peripheral Bus                   RS-232C port                                                                             (See note 2.)
Controller Link
                                                                          Not supported   Supported                       Supported
Ethernet                                                                                                                  (See note 2.)

                                 Connection to PLC with Controller Link Unit via Supported (See note 3.) (CLK (PCI) version is used.) Supported
                                 Controller Link Support Board (PCI board).

                                 Connection to PLC with Controller Link Unit via Supported (CLK (ISA) version is used.)   Supported
                                 Controller Link Support Board (ISA board).

                                 Connection to PLC with Ethernet Unit via Ethernet Supported (Ethernet version is used.)  Supported
                                 Board.

Note: 1. The Windows 2000 and XP operating systems are supported. (Windows 95, 98, and Me are not supported.)
        2. When CX-Server is used for communications, CX-Programmer can be simultaneously connected via the same COM port.
        3. The Windows 95 operating system cannot be used.

                                                                                                                                                 15
Utility Software                                                                                                                                          Touch Panel Software

Utility Software

Touch Panel Software

Face Plate Auto-Builder for NS

Simply specify the CSV tag file created using the CX-Process Tool to automatically create a project constructed with a Face Plate for Loop-control
CPU Units for use with OMRON's NS-series Programmable Terminals.

Function Overview

Create windows for monitoring and tuning PID and other function blocks for up to 100 loops (NS System version 4 or higher).
NS project files for monitoring multiple Loop-control CPU Units from a single NS-series PT can be generated from CX-Process projects for up to

  32 multiple nodes.
When a Segment Program 2 function block is used for program operation, the Detailed Setting Windows (Time Interval vs. Output Value Setting

  Window, Wait Interval Setting Window) used for the parameter settings are also automatically generated.

Basic Specifications

                        Item                                                                                Specifications
Name
Model number                                 Face Plate Auto-Builder for NS
Applicable PLC products
                                             WS02-NSFC1-EV2
Applicable PTs
                                             CJ-series Loop-control CPU Units
System require- Computer                     CS-series Loop Control Boards (unit version 1.0 or later)
                                             CS-series Loop Control Units (unit version 2.0 or later)
ments            CPU                         CS1D Process-control CPU Units

                 OS                          NS-series NS12, NS10, and NS8 (PT version 2.0 or later)
                                             CX-Designer
                 Memory
                                             IBM PC/AT or compatible
                 Hard disk storage
                                             Celeron 400 MHz or better recommended
                 Monitor
                                             Microsoft Windows 95 (see note.), 98, Me, NT4.0, 2000, or XP
Basic functions
                                             Recommended: 32 Mbytes min.

                                             Recommended: 200 Mbytes free space min.

                                             Minimum: 640 x 480 dots

                                             Number of generated loops:100 max., control windows and tuning windows
                                             Applicable face plates: 2-position ON/OFF, 3-position ON/OFF, Basic PID, Advanced PID, Indication and Op-

                                                                             eration, Indicator, Segment Program 2 (includes the parameter setting windows)
                                             Number of loops in control windows: 6 loops per window for NS12, 4 loops per window for NS10/NS8
                                             Realtime trend in tuning window: 1-second cycle

Example of Automatically Created Windows

                                             To Tuning Window                                                  Alarm setting Parameter settings           To Control
                                                                                                                                                          Window
                     Tag No.                                                                   Switch status              Tuning Window
                     Tag comment                                                                                                                          Function
                     Status display 1                        Status display 2                                  Write/read setting data                    Block Face
                     (AUTO, MAN, CAS)                        (PV error, MV error)                                                                         Plate

                     Alarm status                            PV numerical value display
                     indicators
                                                             SP numerical value display/input
                        PV bar display
                                                             Unit display                Realtime trend
                                                             CAS button/display          display

                              Alarm set                      SP bar display
                              value display                  Up/Down buttons to change SP

                      MV indicator                           AUTO button/display
                                                             MAN button/display
                                                                                               Time interval,
                     MV bar display                          MV numerical value                output value,
                                                                                               and unit for
                      Up/Down                                display/input                     each step

                      buttons to change

                      MV

                                     Basic PID Block Screen

                                                                                         Setting confirmation
                                                                                         graph (horizontal axis
                                                                                         shows steps)

                                                                                                                  Segment program details setting window

16
Dimensions                                                                                                                  CPU Units
                                                                                                                                     17
Dimensions

CPU Units

Loop-control CPU Units

CJ1G-CPU42P
CJ1G-CPU43P
CJ1G-CPU44P
CJ1G-CPU45P

                                                  2.7

                                                       SYSMAC          RUN              LCB03   RDY
                                                                       ERR/ALM                 EXEC
                                                       CJ1G-CPU44P             INH
                                                       PROGRAMMABLE                     INNER LOOP CONTROLLER
                                                       CONTROLLER         PRPHL
                                                                          COMM

                                                               OPEN

                                                               MCPWR
                                                               BUSY

            90

                                             PERIPHERAL

                                                 PORT                                                           65
                                                                                                               73.9
            2.7
                                       69

Process Input Units

CJ1W-P@@@@

                                                  2.7

                                                       PTS51           B1           A1

                                                                  RUN
                                                                  ERC
                                                                  ERH

                                                       MACH
                                                       No.

            90

            2.7                                                                                                         65
                              31                                                                               89
Ordering Information                                                                                              Basic Configuration Units

Ordering Information

Basic Configuration Units

    Name                                              Specifications                                              Model                    Standards

Loop-control I/O bits               Program           Data memory capacity LD instruction Number of func- ---                              ---

CPU Unit                            capacity                                     execution time tion blocks

               1,280 (3 Expansion 60 Ksteps           128 K words (DM: 32K 0.04 s                  300 blocks                             UC1, CE, N
               Racks)                                 words, EM: 32 K words 3
                                                      banks)                                                      CJ1G-CPU45P

               960 (2 Expansion     30 Ksteps         64 K words (DM: 32K                                         CJ1G-CPU44P
               Racks)               20 Ksteps         words, EM: 32 K words 1                                   CJ1G-CPU43P
                                    10 Ksteps         bank)                                                       CJ1G-CPU42P

                                                                                                    50 blocks

CPU Units      I/O bits             Program           Data memory capacity       LD instruction     Built-in I/O  ---                      ---
                                    capacity                                     execution time     ---           CJ1H-CPU67H              UC1, CE, N, L
(without Loop                                         448 K words (DM: 32K
                                    250 Ksteps        words, EM: 32 K words x    0.02 s
Control Engine) 2,560 (3 Expansion                    13 banks)

               Racks)

                                    120 Ksteps        256 K words (DM: 32K                                        CJ1H-CPU66H
                                                      words, EM: 32K words 7
                                                      banks)

                                    60 Ksteps         128 K words (DM: 32K                                        CJ1H-CPU65H
                                                                                                                  CJ1G-CPU45H
               1,280 (3 Expansion   30 Ksteps         words, EM: 32K words 3   0.04 s
               Racks)               20 Ksteps         banks)                                                      CJ1G-CPU44H
                                    10 Ksteps                                                                     CJ1G-CPU43H
               960 (2 Expansion                       64 K words (DM: 32K                                         CJ1G-CPU42H
               Racks)                                 words, EM: 32K words 1
                                                      bank)

               640 (1 Expansion     20 Ksteps         32 K words (DM: 32K        0.1 s                           CJ1M-CPU13
               Rack)                                  words, no EM)

               320 (no expansion) 10 Ksteps                                                                       CJ1M-CPU12

               160 (no expansion) 5 Ksteps                                                                        CJ1M-CPU11

               640 (1 Expansion     20 Ksteps                                                       10 inputs and 6 CJ1M-CPU23
               Rack)
                                                                                                    outputs       (See note 1.)

               320 (no expansion) 10 Ksteps                                                                       CJ1M-CPU22
                                                                                                                  (See note 1.)

               160 (no expansion) 5 Ksteps                                                                        CJ1M-CPU21
                                                                                                                  (See note 1.)

Power Supply 100 to 240 V AC (with RUN output), Output capacity: 5 A, 5 V DC                                      CJ1W-PA205R
                                                                                                                  CJ1W-PA202
Units          100 to 240 V AC, Output capacity: 2.8 A, 5 V DC

               24 V DC, Output capacity: 5 A, 5 V DC                                                              CJ1W-PD025

RS-422A Adapt- Converts RS-232C to RS-422A/RS-485.                                                                CJ1W-CIF11
er

I/O Control Unit Mount 1 Unit on the CJ-series CPU Rack when connecting a CJ-series Expansion Rack.               CJ1W-IC101

I/O Interface  1 required on each CJ-series Expansion Rack                                                        CJ1W-II101
Unit

I/O Connecting For connecting CJ-series Expansion Racks to the CJ-series CPU Cable length: 0.3 m                  CS1W-CN313               L, CE
                                                                                                                  CS1W-CN713
Cable          Rack or another CJ-series Expansion Rack.                         Cable length: 0.7 m

                                                                                 Cable length: 2 m                CS1W-CN223

                                                                                 Cable length: 3 m                CS1W-CN323

                                                                                 Cable length: 5 m                CS1W-CN523

                                                                                 Cable length: 10 m               CS1W-CN133

                                                                                 Cable length: 12 m               CS1W-CN133-B2

Memory Cards Flash memory, 30 MB                                                                                  HMC-EF372 (See note 2.)

               Flash memory, 64 MB                                                                                HMC-EF672 (See note 2.)

               Memory Card Adapter (for computer PCMCIA slot)                                                     HMC-AP001                CE

Note: 1. The CJ1M-CPU23/22's connector for built-in I/O is not included. Purchase one of the connectors in the following table separately.

        2. The HMC-EF172, HMC-EF372, and HMC-EF672 Memory Cards cannot be used with the following products. The following CPU Units
             with lot numbers of 020108 or earlier (manufactured 8 January 2002 or earlier): CS1G-CPU@@H, CS1H-CPU@@H, CJ1G-CPU@@H,
             and CJ1H-CPU@@H, and NS7-series PTs with lot numbers of 0852 or earlier (manufactured 8 May 2002 or earlier).

18
Ordering Information                                                                                           Programming Devices

Programming Devices

            Name                                        Specifications                                         Model        Standards

Programming Consoles          An English Keyboard Note: Connects to peripheral port on CPU Unit           CQM1H-PRO01-E     U, C, CE
                                                                                                          CQM1-PRO01-E      U, C, N, CE
                              sheet (CS1W-KS001-E)      only (cannot be connected to RS-232C              C200H-PRO27-E

                              is required.              port).

Programming Console           For CQM1H-PRO01-E, CQM1-PRO01-E, and C200H-PRO27-E                          CS1W-KS001-E      CE
Key Sheet

Programming Console           Connects the CQM1-PRO01-E Programming Console. (Length: 0.05 m)             CS1W-CN114
Connecting Cables             Connects the C200H-PRO27-E Programming Console. (Length: 2.0 m)             CS1W-CN224

                              Connects the C200H-PRO27-E Programming Console. (Length: 6.0 m) CS1W-CN624

CX-One In- 1 license          CX-One is a package that integrates Support Software for OMRON PLCs CXONE-AL01C-E             ---

tegrated    3 license         and components. It can be run in a Windows 98SE, Me, NT 4.0 (Service        CXONE-AL03C-E
Tool Pack-                    Pack 6a), 2000 (Service Pack 3 or later) or XP environment.

age Ver.    10 licenses       CX-One includes CX-Programmer Ver 6.@, CX-Simulator Ver. 1.@, CX-Pro- CXONE-AL10C-E
1.1         30 licenses
            50 licenses       tocol Ver. 1.@, CX-Process Tool Ver. 5.@, CX-Designer Ver. 1.@, and NS-se- CXONE-AL30C-E
                              ries Face Plate Auto Builder Ver. 2.@. Refer to the CX-One catalog (R134)

                              for details. (See note.)                                                    CXONE-AL50C-E

            The CX-Programmer, CX-Simulator, CX-Protocol, CX-Process Tool, CX-Designer, and NS-series Face Plate Auto Builder can still
            be ordered separately, using the following model numbers as before.

CX-Pro-     1 license         Windows-based Support Software                                              WS02-CXPC1-E-V6@ ---
gram-       3 licenses
mer Ver.                      OS: Windows 98SE, Me, NT 4.0 (Service Pack 6a), 2000 (Service Pack 3 or WS02-CXPC1-EL03-
6.@         10 licenses
                              later), or XP                                                               V6@

                                                                                                          WS02-CXPC1-EL10-
                                                                                                          V6@

CX-Pro- 1 license             Support Software for loop control                                           WS02-LCTC1-EV5 ---
cess
Tool Ver.                     OS: Windows 98SE, Me, NT 4.0 (Service Pack 6a), 2000 (Service Pack 3 or
5.@                           later), or XP

CX-Sim- 1 license             Support Software for simulation of ladder program operation                 WS02-SIMC1-E      ---

ulator                        OS: Windows 98SE, Me, NT 4.0 (Service Pack 6a), 2000 (Service Pack 3 or
Ver. 1.@                      later), or XP

CX-Pro- 1 license             Support Software for creating protocol macros                               WS02-PSTC1-E      ---

tocol Ver.                    Use with CJ1G/CJ1H Ver. 1.2 or later, or CJ1M Ver. 1.3 or later.
1.@                           OS: Windows 98SE, Me, NT 4.0 (Service Pack 6a), 2000 (Service Pack 3 or

                              later), or XP

CX-De- 1 license              NS-series PT screen design software                                         NS-CXDC1-V1       ---

signer                        OS: Windows 98SE, Me, NT 4.0 (Service Pack 6a), 2000 (Service Pack 3 or
Ver. 1.@                      later), or XP

                              CX-Designer Ver. 1.0 includes Ladder Monitor software.

                              Note: Ladder Monitor software is NS-series PT software for monitoring lad-
                                      der programs in CS/CJ-series PLCs. To use it, a Memory Card and
                                      Memory Card Adaptor must be ordered separately.

NS-se- 1 license              NS-series PT software for automatic generation of screen data               WS02-NSFC1-EV2 ---
ries Face
Plate                         OS: Windows 98SE, Me, NT 4.0 (Service Pack 6a), 2000 (Service Pack 3 or
Auto                          later), or XP
Builder
Ver. 2.@

CX-Pro- 1 license             Loop control monitoring software for Windows NT4.0, 2000, or XP.            WS02-LCMC1-E      ---
cess Moni- 3 licenses
tor Plus                                                                                                  WS02-LCMC1-EL03

                 10 licenses                                                                              WS02-LCMC1-EL10

Peripheral Device Connect- Connects DOS computers, D-Sub 9-pin receptacle Note: Conversion cable CS1W-CN118                 CE

ing Cables (for peripheral (Length: 0.1 m)                                            to connect RS-

port)                                                                                 232C cable to pe-

                                                                                      ripheral port

                              Connects DOS computers, D-Sub 9-pin (Length: Note: Peripheral bus or CS1W-CN226

                              2.0 m)                                                  Host Link

                              Connects DOS computers, D-Sub 9-pin (Length:                                CS1W-CN626
                              6.0 m)

Note: Site licenses are also available for users that need to use the CX-One on many computers. Ask your OMRON representative for details.

                                                                                                                                 19
Ordering Information                                                                                                               Basic I/O Units

       Name                               Specifications                                                            Model                      Standards
                                                                                                                                               ---
Peripheral Device Connect- Connects DOS computers, D-Sub 9-pin (Length:                   Note: Peripheral Bus XW2Z-200S-CV
                                                                                                  and Host Link,
ing Cables (for RS-232C 2.0 m)                                                                    and ESD connec- XW2Z-500S-CV
                                                                                                  tor (antistatic)
port)                             Connects DOS computers, D-Sub 9-pin (Length:

                                  5.0 m)

                                  Connects DOS computers, D-Sub 9-pin (Length:            Note: Host Link only. XW2Z-200S-V
                                  2.0 m)
                                                                                              Peripheral Bus is
                                  Connects DOS computers, D-Sub 9-pin (Length:
                                  5.0 m)                                                      not possible.         XW2Z-500S-V

USB-Serial Conversion             USB-to-RS-232C Conversion Cable (Length: 0.5 m) and PC driver (on                 CS1W-CIF31
Cable                             CD-ROM), Complies with USB Specification 1.1
                                  On personal computer end: USB (A plug connector, male)
                                  On PLC end: RS-232C (D-sub 9-pin, male)
                                  Driver: Provided for Windows 98, Me, 2000, and XP

Basic I/O Units

Classification             Name                                      Specifications                                Model                      Standards
Input Units
Output Units     DC Input Units           12 to 24 VDC, 8 inputs, 10 mA                                             CJ1W-ID201                 UC, CE, N, L

I/O Units                                 24 V DC, 16 inputs, 7 mA                                                  CJ1W-ID211                 UC1, CE, N, L

                                          24 V DC, 32 inputs, 4.1 mA (Fujitsu-compatible connector)                 CJ1W-ID231 (See note 1.)

                                          24 V DC, 32 inputs, 4.1 mA (MIL connector)                                CJ1W-ID232 (See note 1.)

                                          24 V DC, 64 inputs, 4.1 mA (Fujitsu-compatible connector)                 CJ1W-ID261 (See note 1.)

                                          24 V DC, 64 inputs, 4.1 mA (MIL connector)                                CJ1W-ID262 (See note 1.)

                 AC Input Units           100 to 120 V AC, 7 mA (100 V, 50 Hz), 16 inputs, terminal block           CJ1W-IA111

                                          200 to 240 V AC, 10 mA (200 V, 50 Hz), 8 inputs, terminal block           CJ1W-IA201

                 Interrupt Input Unit     24 VDC, 7 mA, 16 inputs, terminal block                                   CJ1W-INT01

                 High-speed Input Unit 24 VDC, 7 mA, 16 inputs, terminal block                                      CJ1W-IDP01

                 Relay Bit Output Units 250 V AC/24 V DC, 2 A, independent contacts, 8 outputs max.                 CJ1W-OC201

                                          250 V AC/24 V DC, 2 A, independent contacts, 16 outputs max.              CJ1W-OC211

                 Transistor Output Units 250 V AC/24 V DC, 2 A, independent contacts, 8 outputs max.                CJ1W-OD201

                                          24 V DC, 2 A, 8 outputs, sourcing, load short-circuit protection, alarm,  CJ1W-OD202
                                          terminal block

                                          12 to 24 V DC, 0.5 A, 8 outputs, sinking, terminal block                  CJ1W-OD203

                                          24 V DC, 0.5 A, 8 outputs, sourcing, load short-circuit protection, alarm, CJ1W-OD204
                                          terminal block

                                          12 to 24 V DC, 0.5 A, 16 outputs, sinking, terminal block                 CJ1W-OD211

                                          24 V DC, 0.5 A, 16 outputs, sourcing, load short-circuit protection, discon- CJ1W-OD212
                                          nection detection, alarm, terminal block

                                          12 to 24 V DC, 0.5 A, 32 outputs, sinking, Fujitsu-compatible connector CJ1W-OD231 (See note 1.)

                                          24 VDC, 0.5 A, 32 outputs, sourcing, load short-circuit protection, alarm, CJ1W-OD232 (See note 1.)
                                          MIL connector

                                          12 to 24 VDC, 0.5 A, 32 outputs, sinking, MIL connector                   CJ1W-OD233 (See note 1.)

                                          12 to 24 VDC, 0.3 A, 64 outputs, sinking, Fujitsu-compatible connector CJ1W-OD261 (See note 1.)

                                          24 VDC, 0.3 A, 64 outputs, sourcing, MIL connector                        CJ1W-OD262 (See note 1.)

                                          12 to 24 VDC, 0.3 A, 64 outputs, sinking, MIL connector                   CJ1W-OD263 (See note 1.)

                 Triac Output             Unit 250 VAC, 0.6 A, 8 outputs, terminal block                            CJ1W-OA201

                 DC Input/Transistor Out- 16 inputs, 24 V DC, 7 mA                            Fujitsu-compatible    CJ1W-MD231 (See note 2.) UC1, CE, N

                 put Units                16 outputs, 12 to 24 V DC, 0.5 A, sinking outputs connector

                                          16 inputs, 24 V DC, 7 mA                            MIL connector         CJ1W-MD232 (See note 2.)

                                          16 outputs, 24 V DC, 0.5 A, sourcing outputs, load
                                          short-circuit protection, alarm

                                          16 inputs, 24 V DC, 7 mA                            MIL connector         CJ1W-MD233 (See note 2.)

                                          16 outputs, 12 to 24 V DC, 0.5 A, sinking outputs

                                          32 inputs, 24 V DC, 4.1 mA                          Fujitsu-compatible    CJ1W-MD261 (See note 1.)

                                          32 outputs, 12 to 24 V DC, 0.3 A, sinking outputs connector

                                          32 inputs, 24 V DC, 4.1 mA                          MIL connector         CJ1W-MD263 (See note 1.)

                                          32 outputs, 12 to 24 V DC, 0.3 A, sinking outputs

                 TTL I/O Unit             32 inputs, 5 V DC, 35 mA                            MIL connector         CJ1W-MD563 (See note 1.)

                                          32 outputs, 5 V DC, 35 mA

20
Ordering Information                                                                                                               Special I/O Units

Classification      Name                                       Specifications                                              Model              Standards
B7A Interface Units                                                                                           CJ1W-B7A14                     CE
                                          64 inputs                                                           CJ1W-B7A04
                                          64 outputs                                                          CJ1W-B7A22
                                          32 inputs/32 outputs

Note: 1. Connectors are not provided with these connector models. Either purchase one of the following 40-pin Connectors, or use an OMRON
            XW2@ Connector-Terminal Block Conversion Unit or a G7@ I/O Relay Terminal.

        2. Connectors are not provided with these connector models. Either purchase one of the following 20-pin or 24-pin Connectors, or use an
            OMRON XW2@ Connector-Terminal Block Conversion Unit or a G7@ I/O Relay Terminal.

                                                                                                              This eco label is displayed
                                                                                                              only on products that satisfy
                                                                                                              stringent environmental
                                                                                                              standards established by
                                                                                                              OMRON.

Special I/O Units

     Type                       Name                            Specifications                                Model                            Standards
             Analog Input Units                                                                                                              UC1, CE, N, L
Special I/O                               8 inputs (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA)   CJ1W-AD081-V1                  UC1, CE, N
Units                                     Resolution: 1/8000, Conversion speed: 250 s/point max.                                            UC1, CE, N, L
                                          (Settable to 1/4000 and 1 ms/point.)                                                               UC1, CE

                                          4 inputs (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA)   CJ1W-AD041-V1                  UC1, CE, N L
                                          Resolution: 1/8000, Conversion speed: 250 s/point max.
                                          (Settable to 1/4000 and 1 ms/point.)                                                               ---

             Analog Output Units          8 outputs (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V)              CJ1W-DA08V
                                          Resolution: 1/4000, Conversion speed: 1 ms/point max.

                                          (Settable to 1/8000, 250 s/point)

                                          8 outputs (4 to 20 mA)                                              CJ1W-DA08C

                                          Resolution: 1/4000, Conversion speed: 1 ms/point max.
                                          Settable to 1/8000, 250 s/point)

                                          4 outputs (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA)  CJ1W-DA041
                                          Resolution: 1/4,000, Conversion speed: 1 ms/point max.

                                          2 outputs (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA)  CJ1W-DA021
                                          Resolution: 1/4000, Conversion speed: 1 ms/point max.

             Analog I/O Units             4 inputs, 2 outputs (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA) CJ1W-MAD42
             Process Input Units          Resolution: 1/4000, Conversion speed: 1 ms/point max.
             (High Resolution Models)     (Settable to 1/8000, 250 s/point)

             Process Input Units          2 inputs, B, E, J, K, L, N, R, S, T, U; WRe5-26; PL II; 100 mV     CJ1W-PTS15
             (Economy Models)
             Temperature Control Units    Resolution: 1/64,000; Conversion speed: 10 ms/Unit

                                          2 inputs, Pt 100  (JES, IEC), JPt 100 , Pt 50 , Ni 508              CJ1W-PTS16
                                          Resolution: 1/64,000; Conversion speed: 10 ms/Unit

                                          2 inputs, 0 to 100 V, 10 V, 0 to 5 V, 5 V, 0 to 1.25 V, 1.25 V   CJ1W-PDC15

                                          Resolution: 1/64,000; Conversion speed: 10 ms/Unit

                                          4 inputs, R, S, K, J, T, L, B; Conversion speed: 250 ms/4 inputs    CJ1W-PTS51

                                          4 inputs, Pt 100  (JIS, IEC), JPt100 , Conversion speed: 250 ms/4 in- CJ1W-PTS52
                                          puts

                                          4 loops, thermocouple input, NPN output                             CJ1W-TC001

                                          4 loops, thermocouple input, PNP output                             CJ1W-TC002

                                          2 loops, thermocouple input, NPN output, heater burnout detection func- CJ1W-TC003
                                          tion

                                          2 loops, thermocouple input, PNP output, heater burnout detection func- CJ1W-TC004
                                          tion

                                          4 loops, platinum resistance thermometer input, NPN output          CJ1W-TC101

                                          4 loops, platinum resistance thermometer input, PNP output          CJ1W-TC102

                                          2 loops, platinum resistance thermometer input, NPN output, heater burn- CJ1W-TC103
                                          out detection function

                                          2 loops, platinum resistance thermometer input, PNP output, heater burn- CJ1W-TC104
                                          out detection function

             High-speed Counter Unit      2 inputs, max. input frequency: 500 kpps                            CJ1W-CT021
             CompoBus/S Master Unit
             ID Sensor Units (See note.)  CompoBus/S remote I/O, 256 points max.                              CJ1W-SRM21

                                          For V600 Series, 1 R/W Head                                         CJ1W-V600C11

                                          For V600 Series, 2 R/W Heads                                        CJ1W-V600C12

Note: Refer to the FA System Devices Group Catalog for details on the V600 Series RFID System.

                                                                                                                                             21
Ordering Information                                                                                                         CPU Bus Units

CPU Bus Units

     Type               Name                                                       Specifications      Model                   Standards
                                                                                                                             UC1, CE, N, L
CPU Bus    Controller Link Units  Wired (Shielded twisted-pair cable)                                  CJ1W-CLK21-V1         ---
Units                                                                                                                        CE
           Controller Link Relay Terminal Wired                                                        CJ1W-TB101            UC1, CE
                                                        Includes 5 Terminals
                                                                                                                             UC1, CE, N, L
           Controller Link Support Board Twisted pair, PCI bus (wired), with Support Software          3G8F7-CLK21-EV1
                                                                                                                             UC1, CE, N, L
           Controller Link Repeater Units Wired-wired type                                             CS1W-RPT01
                                                                                                                             UC1, CE
                                  Wired-optical (H-PCF) type                                           CS1W-RPT02            UC1, CE, N, L
                                                                                                                             ---
                                  Wired-optical (GI) type                                              CS1W-RPT03

           Serial Communications Units 1 RS-232C port and 1 RS-422/485 port                            CJ1W-SCU41-V1

                                  2 RS-232C ports                                                      CJ1W-SCU21-V1

           Ethernet Units         10Base-T                                                             CJ1W-ETN11

                                  100Base-TX                                                           CJ1W-ETN21

           FL-net Unit            100Base-TX                                                           CJ1W-FLN22

           DeviceNet Unit         Functions as master and/or slave; allows control of 32,000 points max. per CJ1W-DRM21
                                  master.

           Position Control Unit  Equipped with MECHATROLINK-II, multiple axis control for 16 axes max. CJ1W-NCF71

NS-series Programmable Terminals

            Model name                                           Specifications            Case color          Model number   Standards
NS12                                                                          Ethernet  Ivory                                CU, CE
NS10                                                                                    Black          NS12-TS00-V2
NS8                           12-inch TFT, 800 600 dots No                            Ivory          NS12-TS00B-V2         CE, CU
NS5                                                                                     Black          NS12-TS01-V2          (approval
                                                                              Yes       Ivory          NS12-TS01B-V2         pending)
NS5 Hand-held                                                                           Black          NS10-TV00-V2
                              10-inch TFT, 640 480 dots No                            Ivory          NS10-TV00B-V2
                                                                                        Black          NS10-TV01-V2
                                                                              Yes       Ivory          NS10-TV01B-V2
                                                                                        Black          NS8-TV00-V2
                              8-inch TFT, 640 480 dots No                             Ivory          NS8-TV00B-V2
                                                                                        Black          NS8-TV01-V2
                                                                              Yes       Ivory          NS8-TV01B-V2
                                                                                        Black          NS5-SQ00-V2
                              5-inch STN, 320 240 dots No                             Ivory          NS5-SQ00B-V2
                                                                                        Black          NS5-SQ01-V2
                                                                              Yes       Ivory          NS5-SQ01B-V2
                                                                                        Black          NS5-TQ00-V2
                              5-inch TFT, 320 240 dots No                             Ivory          NS5-TQ00B-V2
                                                                                        Black          NS5-TQ01-V2
                                                                              Yes       Ivory          NS5-TQ01B-V2
                                                                                        Black          NS5-MQ00-V2
                              5-inch, monochrome,                             No        Ivory          NS5-MQ00B-V2
                                                                                        Black          NS5-MQ01-V2
                              320 240 dots                                            Black          NS5-MQ01B-V2
                                                                                                       NSH5-SQR001B-V2
                                                                              Yes

                              5-inch STN, 320 240 dots No

22
Ordering Information                                                                                         Ordering Information

Model name                                          Specifications                                     Model number
                                                                                               XW2Z-S002
Cable (See note 1.)         Screen transfer cable for DOS/V                                    NS-US52 (5 m)
                                                                                               NS-US22 (2 m)
                            USB Host Cable, cable length: 5 m                                  CS1W-CIF31
                                                                                               NSH5-422CW-10M
                            USB Host Cable, cable length: 2 m                                  NSH5-232CW-3M
                                                                                               NSH5-232CW-10M
                            USB-RS-232C Conversion Cable, cable length: 0.5 m                  XW2Z-200T
                                                                                               XW2Z-500T
NSH5 Cables                 RS-422A cable (loose wires), Cable length: 10 m                    NSH5-ATT02

                            RS-232C cable (loose wires), Cable length: 3 m

                            RS-232C cable (loose wires), Cable length: 10 m

PT-to-PLC Connecting Cable PT connection: 9 pins                             Length: 2 m

                            PLC connection: 9 pins                           Length: 5 m

NSH5 Wall-mounting Bracket

Note: 1. Use an OMRON USB Host Cable to connect an NS-series PT to a printer.
        2. Site licenses are also available for users that need to use the CX-One on many computers. Ask your OMRON representative for details.

Options

            Model name                              Specifications                             Model number
RS-422A Adapter
                            Transmission distance: 500 m total length                          NS-AL002
Sheet/Cover
                            Note: Use this model when connecting PT models without a V@ suf-
                                    fix.

                            Note: PT models with a suffix of V@ can also be connected.

                            Transmission distance: 50 m total length                           CJ1W-CIF11

                            Note: Only PT models with a suffix of V@ are connectable. Use the
                                    NS-002 to connect models without a V@ suffix.

                            Anti-reflection Sheets (5 surface sheets)        NS12/10           NS12-KBA04

                                                                             NS8               NS7-KBA04

                                                                             NS5               NT30-KBA04

                            Protective Covers (5 pack)                       NS12/10           NS12-KBA05
                            (anti-reflection coating)                        NS8               NS7-KBA05

                                                                             NS5               NT31C-KBA05

                            Protective Covers (5 covers included)            NS12/10           NS12-KBA05N

                            (Transparent)                                    NS8               NS7-KBA05N

                                                                             NS5               NT31C-KBA05N

Ordering Information

International Standards                                                EMC-related performance will vary depending on the configuration,
                                                                       wiring, and other conditions of the equipment or control panel in
The standards indicated in the "Standards" column are those cur-     which the PLC is installed. The customer must, therefore, perform
  rent for UL, CSA, cULus, cUL, NK, and Lloyd standards and EC         final checks to confirm that the overall machine or device conforms to
  Directives as of the end of September 2004. The standards are        EMC standards.
  abbreviated as follows: U: UL, UR: UL Recognition Mark, U1: UL
  Class I Division 2 Products for Hazardous Locations, C: CSA, UC:     Note: The applicable EMS standard depends on the product.
  cULus, UC1: cULus Class I Division 2 Products for Hazardous
  Locations, CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.          Low Voltage Directive

Ask your OMRON representative for the conditions under which the     Applicable Standard: EN61131-2
  standards were met.
                                                                       Devices that operate at voltages from 50 to 1,000 V AC or 75 to 150
EMC Directives                                                         V DC must satisfy the appropriate safety requirements. With PLCs,
                                                                       this applies to Power Supply Units and I/O Units that operate in these
Applicable Standards                                                   voltage ranges.
   EMI: EN61000-6-4                                                    These Units have been designed to conform to EN61131-2, which is
   EMS: EN61131-2 and EN61000-6-2 (See note.)                          the applicable standard for PLCs.

PLCs are electrical devices that are incorporated in machines and
manufacturing installations. OMRON PLCs conform to the related
EMC standards so that the devices and machines into which they are
built can more easily conform to EMC standards. The actual PLCs
have been checked for conformity to EMC standards. Whether these
standards are satisfied for the actual system, however, must be
checked by the customer.

                                                                                                                     23
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved