CCL225DA2-ACF2

器件型号:CCL225DA2-ACF2
器件类别:电路保护   
厂商名称:ETC
下载文档

器件描述

TIME DELAY BLOW ELECTRIC FUSE, 100A, 125VDC, INLINE/HOLDER

CCL225DA2-ACF2器件文档内容

                                                                                                                                     TYPE:
                                                                                                                                     CATALOG NO.:

General Description                                                 CCL/TCL Series
   The CCL/TCL Series provides functional emer-
                                                                    High Capacity Steel Emergency Lighting Units
gency lighting in a variety of wattages up to 450
watts. High performance electronics and rugged                      6 and 12 Volt, 75 to 450 Watts
18 gauge steel construction ensure long-term life                   Wet Cell Lead Calcium Battery
safety reliability.
                                                                    Housing
Illumination                                                        Constructed of 18 gauge steel with a tan epoxy powder
   Illumination is accomplished with up to three                    coat finish.

lamp heads mounted on the top of the unit. The                      Knockouts provided for mounting up to three lamp
most popular lamp head for use with the CCL/TCL                     heads.
Series is the "D" Series round sealed beam Par 36
tungsten lamp head. The "D" head is available up                    Bi-color LED charge monitor/indicator and a "press-to
to 30 watts.                                                        test" switch are located on the front of the cabinet.

Dimensions                                                          Choice of wedge base, sealed beam tungsten, or halogen
CCL75, CCL100, CCL150, CCL225,                                      lamp heads
TCL150, TCL200
                                                                    Electronics                                                                         Shown: CCL150DL2
                                              6.0"
                                                                    120/277 VAC dual voltage input with surge-protected,               Battery
                                                         (15.2 cm)  solid-state circuitry provides for a reliable charging             Low maintenance, free electrolyte, wet cell, lead
                                                                    system.                                                            calcium battery

           16.0"                   12.0"                            Charging system is complete with low voltage                       Specific gravity disk indicators show relative state
                                                                    disconnect, AC lockout, brownout protection,                       charge at a glance
             (40.6 cm)               (30.5 cm)                      AC indicator lamp and test switch.
                                                                                                                                       Operating temperature range of battery is 65F
TCL300, TCL450           7.6"                                       Includes two fused output circuits.                                (19C) to 85F (30C)

                        (19.3 cm)                                   Utilizes a fully automatic voltage regulated two-rate cur- Battery supplies 90 minutes of emergency power

                                        6.0"                        rent limited solid-state charger -- initially provides a high

                                          (15.2 cm)                 rate charge upon restoration of AC power, and provides Code Compliance

                                        12.0"                       trickle charge to maintain batteries at full capacity once UL 924 listed

                                           (30.5 cm)                float voltage is attained.                                         NFPA 101

                                                                    Optional ACCU-TEST Self Diagnostics includes an auto-              NEC BOCA and OSHA illumination standard
                                                                    matic 3 minute discharge test every 30 days. A manual

                                                                    test is available from 1 to 90 minutes.                            Performance

27.0"                                    7.6"                      Warranty                                                           Input power requirements
                                                                    Three year full electronics warranty                                 120 VAC - 0.66 amps, 80 watts
(12.7 cm)                                (19.3 cm)                                                                                       277 VAC - 0.30 amps, 80 watts
                                                                    One year full plus four year prorated battery warranty

Ordering Information

CCL                     150                                         DL                                           2  TD1

    SERIES                   DC                                            LAMP                 # OF                FACTORY INSTALLED
                         WATTAGE                                          HEADS               HEADS
CCL = 6 Volt            6 Volt                                      6 Volt                   3 = Three                          OPTIONS 1               ACCESSORIES
TCL = 12 Volt           75 = 75 Watts                               DY = 8 Watt, Tungsten    2 = Two                A = Ammeter 2
                        100 = 100 Watts                             DA = 18 Watt, Tungsten   1 = One
                        150 = 150 Watts                             DL = 25 Watt, Tungsten                          ACF1 = 120 VAC Fuse                 LMSHELF = Mounting Shelf 300-450W
                        225 = 225 Watts                             DC = 30 Watt, Tungsten                          ACF2 = 277 VAC Fuse                 MXSHELF = Mounting Shelf 72-200W
                                                                                                                    ACP1 = 120 VAC Power Switch

                                                                                                                    ACP2 = 277 VAC Power Switch

                                                                                                                    AD = ACCU-TEST Self-Diagnostics

                        12 Volt (Includes standard voltmeter)       12 Volt                                         ADAL = ACCU-TEST with Alarm
                        150 = 150 Watt                              DNY = 12 Watt, Tungsten
                        200 = 200 Watt                              DE = 28 Watt, Tungsten                          ADTD = ACCU-TEST with Time Delay 3
                        300 = 300 Watt                              DK = 25 Watt, Tungsten
                        450 = 450 Watt                              DG = 30 Watt, Tungsten                          DCP = DC Power Switch

                                                                                                                    EX = Special Input Transformer (Specify voltage and frequency)

                                                                                                                    TD1 = 120 VAC Time Delay 3
                                                                                                                    TTD2 = 277 VAC Time Delay 3

                                                                    (Suggested lamp heads listed                    V = Voltmeter 2
                                                                    above. Refer to the Accessories Section for
Notes:                                                              additional lamp head choices.)                  W = White Housing
1) Some option combinations may impact UL list-
ing. consult factory for specifics.
2) Not available witj AD, ADAL, or ADTD options.
3) 15 minute delay.

                                                                                                                                                                                    C1063R4
                                                                                                                                                                                    9/02 IH
Specification Data for CCL/TCL Series Steel Emergency Lighting Units

Housing                                                    Electronics                                               Self-Diagnostics
18 gauge steel housing with a tan epoxy powder coat        120/277 VAC dual voltage input with surge-protect-        The ACCU-TEST Self-Diagnostics option conducts
finish.                                                    ed, solid-state charging circuitry provides for a         automatic and manual tests, and indicates real time
                                                           reliable charging system. The charging system is          status of the lamp, battery and charger via LED indica-
Knockouts provided for mounting up to three lamp           furnished with low voltage disconnect, AC lockout,        tor lamps. Automatic tests include: Systems analysis
heads.                                                     brownout protection, AC indicator lamp and test           every 10 seconds, with actual load tests performed for
                                                           switch.                                                   a 3 minute duration every 30 days. A manual tests is
The suggested lamp head is the "D" Series round                                                                      available from 1 to 90 minutes.
sealed beam Par 36 tungsten. To order lamp heads           The low voltage disconnect (LVD) feature will dis-
other than the suggested "D" head, refer to Chloride       connect the battery prior to an unacceptable deep         Battery
Accessories Section..                                      discharge, but not before the required 90 minute          Low maintenance, free electrolyte, wet cell, lead calci-
                                                           emergency operation.                                      um battery.
Lamp Head Photometrics
(For DL, suggested head for CCL)                           The AC lockout feature prevents battery drain prior to    Standard sustained emergency operation is for 90
                                                           the initial energizing of utility power, and allows the   minutes with the illumination source providing full
                 Horizontal                                installer to complete all wiring and electrical connec-   light output.
                                                           tions without energizing the emergency circuit.
      Left 30

       20                                                  The brownout protection circuitry will automatically
                                                           switch the unit into the emergency mode if the utility
       10           1         .5      .3 .2      .1        voltage sags below 20% of nominal.                        The suggested operating temperature range for lead
feet 0                                                                                                               calcium batteries is 65F (19C) to 85F (30C) and
                                                           Battery charging circuitry is entirely solid-state, and   should provide a service life of 5 years.
       10                                                  utilizes a fully automatic, voltage regulated charger.
                                                           Battery recharge time after full discharge is less than   Performance
       20                                                  the required UL 924 standard.                             Input power requirements

Right 30                                                   Line sensitive electronics cause an instantaneous           120 VAC - 0.66 amps, 80 watts
                                                           transfer to battery power if utility power is lost, or a    277 VAC - 0.30 amps, 80 watts
           0        10 20 30 40 50 60 70           80      brownout condition is detected. When line voltage is
                                                           present and stabilized, the transfer circuitry switches   Code Compliance
Up 20                                                      back to normal operation and begins recharging the        The CCL/TCL Series meets or exceeds all performance
                                                           battery. The transfer circuitry can be tested via a       standards as required by UL 924, NFPA 70, NFPA 101,
       10                  1      .5  .3 .2            .1  momentary test switch located on the housing.             NEC and OSHA.
feet 0

       10

Down 20

           0        10 20     30 40   50 60 70         80

                           Photometric No. 3

(For DK, suggested head for TCL)

                      Horizontal

             Left 20

                                                           Operation

              10    1 .5 .3 .2               .1            DC                                                        Suggested            Watts to 871/2
       feet 0                                                                                                        Lamp Head         of Rated Voltage*
                                                                                                                                11/2 hrs. 2 hrs. 4 hrs. 8 hrs.
                                                           Voltage  Unit                                                 DL       75 56 28.5 15
                                                                                                                         DL      100 75 38 20
           10                                                                                                            DL      150 112.5 57 30
                                                                                                                         DL      225 169 85.5 45
Right 20            10 20 30          40 50 60 70          6        CCL75                                                DK      150 112.5 57 30
                 0                                                                                                       DK      200 150 96 34
                                                                                                                         DK      300 225 114 60
                                                                    CCL100                                               DK      450 337.5 171 90

               Vertical                                             CCL150

       Up 20

                                                                    CCL225

              10                                           12 TCL150
       feet 0
                    1 .5 .3 .2               .1                     TCL200

           10                                                       TCL300

Down 20                                                             TCL450
                 0
                    10 20 30 40 50 60 70

Suggested Specification
Furnish and install Chloride Systems emergency lighting unit model ________. The unit shall be constructed to meet Underwriter's Laboratories, Inc. Standard #924
and the National Electrical Code (NEC).

INSTALLATION AND OPERATION - Unit shall be easily field connected to a 120 or 277 VAC, 60 hertz, unswitched power source. Installation must comply with the
NEC as well as other applicable codes. Upon utility power failure or brownout, the unit shall automatically transfer to battery power and maintain the required illumina-
tion level for a minimum period of 90 minutes. Upon restoration of utility power, the charger shall restore the battery to full charge within UL 924 requirements follow-
ing a rated discharge of not more than 90 minutes.

CHARGER - Product shall utilize a fully automatic, voltage regulated, two-rate current limited solid-state charger. The charging system shall maintain the battery at
full capacity without the need for periodic exercising or equalization. The following features shall be standard: Low voltage disconnect (LVD), brownout protection and
AC lockout.

BATTERY - The battery shall be a low maintenance, free electrolyte, wet cell, lead calcium battery. The lead calcium battery shall provide trouble-free operation in
temperatures up to 85F (30C).

HOUSING - The unit housing shall be constructed of 18 gauge steel with a tan epoxy powder coat finish.

A2528               ISO 9001                               272 West Stag Park Service Road Burgaw NC 28425                    C1063R4
                                                           Telephone: (910) 259 1000 Facsimile: (800) 258 8803                9/02 IH
                                                           www.chloridesys.com
Chloride Systems
This datasheet has been downloaded from:
             www.EEworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved