NEW                     Radiometrix

                        Hartcran House, 231 Kenton Lane, Harrow, HA3 8RP, England

Issue A, 03 April 2008  Tel: +44 (0) 20 8909 9595, Fax: +44 (0) 20 8909 2233       BHX2

    NBFM Multi-channel 500mW UHF Transceiver

The BHX2 transceiver module offers a
500mW RF power output in the UK
458MHz band. This makes the BHX2
ideally suited to those low power
applications where existing multi-
channel narrow band devices like
TR2M have insufficient range.

                                                      Figure 1: BHX2-458-5-SMA

Features

         Conforms to EN 300 220-3 and EN 301 489-3
         Any 5MHz band module from 420 - 480MHz available as factory tuned custom variant
         High performance double superhet, 128 channel PLL Synthesizer with TCXO
         Data rates up to 5 kbps for standard module
         Usable range over 5km
         Fully screened
         Feature-rich interface (RSSI, automatic noise squelch, analogue and digital baseband)
         Incorporates a 1200baud dumb modem
         User configurable via RS232 interface
         Low power requirements

Applications

         Handheld terminals
         Heavy vehicle/machine remote controls
         EPOS equipment, barcode scanners
         Data loggers
         Industrial telemetry and telecommand
         In-building environmental monitoring and control
         High-end security and fire alarms
         Vehicle data up/download

Technical Summary

     Operating frequency: 458.5-459.1MHz
     Custom variants from 420MHz to 480MHz on any 5MHz band
     23 channels in 458MHz band (128 channels max.)
     Transmit power: +27dBm (500mW) nominal
     Supply range: 5.5V - 15V

     Current consumption: 350mA transmit, 30mA receive
     Data bit rate: 5kbps max. (standard module)
     Receiver sensitivity: -118dBm (for 12 dB SINAD)
     Size: 85 x 39 x 13 mm (RF pin version)

Radiometrix Ltd                BHX2 Data Sheet                                     page 1
                                  Figure 2: BHX2 block diagram

Radiometrix Ltd  BHX2 Data Sheet                                page 2
                 Figure 3: BHX2 Footprint (Top) view

User Interface

Pins  Name       Function
1     TXE        Transmitter Enable. Low = ON, Open = RX mode. Internal 10k pull-up to
                 4V
2     TXD        DC coupled digital data input for 3-12V CMOS logic. Leave open if unused
3     AF in      50mV - 2.5v p-p AC coupled input. Variable gain
4     RSSI       DC level between 0.5V and 2.5V. 60dB dynamic range
5     SQF        Noise operated carrier detect. Open collector. ON/low = no signal
6     AF out     200mVpk-pk audio. DC coupled, approx 1V bias. Muted by squelch
7     RXD        Open collector output of data slicer suitable for Biphase codes
8     +4.4V out  Regulated DC supply. 75mA max. drain. Present if unit is powered
9     0V         Ground
10    PGM        Serial programming/configuration input at RS232 level
11    P1
12    P2         Parallel frequency select inputs. Inverted logic, internal 10k pullups to
13    P3         4.4V

Notes:
    1. BHX2 transmitter section inverts sense of the baseband stream, so a logical inversion is
         present between input of TX and output on RX
    2. Carrier detect mutes the AF and DATA outputs. It can be disabled by rotating the level
         set trimmer fully ACW.
    3. There are no pullups on the open collector outputs.
    4. The sofware incorporates a 1200baud dumb modem, compatible with that implemented
         in TX2M, RX2M, TR2M, SMX2 and UHX2 radios ( i1200 tones and format ).
    5. RS232 input pins (10 and 11) tolerate true +/- levels. No buffering is required.
    6. This unit actually consists of a TR2C RF board and an AFS2-458 amplifier module,
         combined with a 5v LDO
    7. In future versions of the software, pin 13 will have a modem handshake function
    8. The BHX2 has the same footprint/pinout/function as the TR2M (TR2B), but the case is
         longer, and the RF output is a coaxial connector. Compared to an TR2M, the minimum
         supply voltage is higher (5.5v vesus 4.5v).

Radiometrix Ltd  BHX2 Data Sheet                      page 3
                     TXE (MOD TX_ON) (1)                         Transmit Enable
                                       TXD (2)                   Data Out
                                      AF in (3)                                    Host Microcontroller
                                       RSSI (4)                  ADC
                                       SQF (5)                                                                      PC serial port
                                                 1kCarrier Detect                                                                      1
                 BHX2 AF out (6)                                          Data In                                                 6
                                       RXD (7)                                                                                            TXD
                              +4.4V out (8)          10k         VDD                                                                  2   SGD
                                      GND (9)                                                                                     73
                                    PGM (10)              100nF                                                                   8
                                        P1(11)
                                       P2 (12)                                                                                        4
                                       P3 (13)                                                                                    9

                                                                                                                                      5

                                                                 Parallel
                                                                 Channel
                                                                 Select

Figure 4: BHX2 interfaced to host microcontroller and serial port for configuration

BHX2 can be directly interfaced to a host microcontroller which can generally be powered by
the regulated +4.4V output on pin 8 of BHX2. Three I/O pins on the microcontroller port can
be assigned to select the first 8 channels on frequency table of the appropriate band for which
the module is configured by pulling the P1-P3 pins low. Channel select pins of BHX2 have
internal pull-up to 4V supply rail, hence channel selection operate on inverted logic.

                 Channel                             P3:P2:P1                      458MHz band
                 0                                   111                           458.525
                 1                                   110                           458.550
                 2                                   101                           458.575
                 3                                   100                           458.600
                 4                                   011                           458.625
                 5                                   010                           458.650
                 6                                   001                           458.675
                 7                                   000                           458.700

Digital Received Data Output (RXD) pin is an open collector output, which should be pulled-
up to required voltage swing level (e.g. +4.4V or Vcc).

BHX2 has an automatic noise squelching function which is activated when there is not any RF
signal at detectable level on the channel or if the non-coherent noise like interference level is
high enough to block any weak RF signal from being received. SQF is provided as an open-
collector output for monitoring which should be pulled-up to required voltage swing level. SQF
output will jump to pull-up voltage level if received RF signal level at the RF In/Out pin of the
module is about 3dB below the level required to produce 12dB SINAD level on demodulated
AF Output signal. SQF pin can be connected to an LED to act as a Carrier Detect indicator.

Pull-up resistor value should be reduced (e.g. 1k) according to the current requirement to
produce satisfactory brightness on the LED used.

BHX2 can be configured using any PC/Laptop/PDA having a serial port and modem/terminal
program. TXD (pin 3) of DB9M connector can be directly wired to PGM (pin C10) of the BHX2
and SGN (pin 5) of DB9M connector should be either connected to common ground or pin C9 of
the BHX2.

The whole frequency/channel table is user reconfigurable to 128 channels within 5MHz band
of supplied frequency subject to regulatory band limits. Serial Channel Selection via PGM pin
gives access to the whole of regulatory band allocation for 458.525MHz-458.925MHz (23
channels).

Radiometrix Ltd                                           BHX2 Data Sheet                                                                      page 4
                                        Received Signal StrengthRSSI output (V)
             2.5
             2.3
             2.1
             1.9
             1.7
             1.5
             1.3
             1.1
             0.9
             0.7
             0.5

                 -130 -120 -110 -100 -90 -80 -70 -60 -50 -40
                                                      RF Level (dBm)

                           Figure 5: RSSI voltage variation with respect to RF level at BHX2

If the microcontroller has a built-in Analogue to Digital Converter (ADC), the Received Signal
Strength Indicator (RSSI) output voltage level can be read by the microcontroller to estimate
its distance from transmitting BHX2 unit or identify areas of weak signal reception.
RSSI can also be used to make a decision to switch to the second antenna in fixed installations
within building where the probability of null-spots are higher.

Radiometrix Ltd  BHX2 Data Sheet  page 5
                        BHX2 serial configuration commands

2400 baud RS232. 8 bit data, no parity, 1 start bit, 1 or 2 stop bits, No flow control

SINGLE nnnnn            Set value of N for single channel operation

GOCHAN xx               Serial select of channel xx (0 to 127)

LOADMX xx               Set highest permitted (serial selected) channel xx (others default to
                        ch0)

LOAD aa nnnnn           Set value of N for channel aa (channels 0 to 15)

LOADTB nnnnn            Set value of N for channel 16 (channels 17 to 127 then in sequence)

RVALUE rrrr             Enter value for R register

SETPAR                  Channel selected by 3 bit parallel input (0 to 7). Disable modem

SETSER                  Channel selected by most recent 'gochan' operation

SETMOD                  Enable internal modem. Frequency selected by most recent 'gochan'
                        or 'single'

OFFSET                  Set receive frequency offset (for 25KHz this is 1800)

GOTEST                  250Hz test tone transmission

                    Process entry

/                       Clear all buffers

xx = channel number from 00 to 127
aa = two digit channel number from 00 to 15

nnnnn = synthesizer N register value, (up to 65535)
rrrr = synthesizer R register value, (up to 16383)

N = f RF = 458.525MHz = 18341                R = fTCXO = 13MHz , So R=520
      f Channelspacing  25kHz                     f channelspacing 25kHz

On receive, the local oscillator operates at 45MHz (the first IF) below the carrier.
An OFFSET value is subtracted from the channel's N value when the unit is switched into RX

      OFFSET = First IF / Fc, so, OFFSET = 45MHz / 25KHz = 1800 (usually)

Notes:
    1. A pause of at least 50ms must be allowed between command strings (EEPROM
         programming time)
    2. SINGLE mode does not store the N value in EEPROM. Therefore the unit is inoperative
         after a power down until either another valid SINGLE command is received, or mode is
         changed by a GOCHAN, SETPAR or SETSER command. SINGLE mode is intended
         for frequency agile applications.
    3. /SETPAR command should be issued at the end of channel programming to put the
         module back into parallel frequency select mode
    4. In 458MHz band, channel 12 (458.825MHz) and channel 15 (458.900MHz) are
         allocated specifically for fixed alarm and radio keys/vehicle paging applications
         respectively and should not be used for general purpose applications.
    5. User can modify the frequency table of 128 channels to any desired frequency by

         changing N, R values of synthesizer within 2.5MHz of factory set Channel 0 frequency
         subject to the Radio Regulatory Band Allocation in the country of intended use.
    6. All other frequency, power, analogue input gain and automatic noise squelching
         adjustment will be treated as custom variants of the module to be set by factory.

Radiometrix Ltd                        BHX2 Data Sheet                                    page 6
                 Pin description of BHX2 with Modem mode selected

The 'modem' mentioned is a 1200 baud RS232 semi-intelligent unit (Transmit keyed when
valid serial data is present, so no separate TX control needed. Coding in the datastream also
permits the receiver to ignore noise and only output valid serial data). This is a half duplex
unit, so collisions between transmitted and received packets must be dealt with by the user.

Pin Name         Function
                 Open = normal modem operation. Low = constant TX (for test). 10k
1  MOD TX_ON     pullup to 4V
                 Leave open
2  MOD NC        Leave open
                 DC level between 0.5V and 2.5V. 60dB dynamic range
3  MOD NC        Leave open
                 Modem tones or noise present
4  RSSI          Leave open
                 Regulated DC supply. 75mA max. drain. Present if unit is powered
5  MOD NC        Ground

6  AF out        Serial programming/configuration input at RS232 level

7  NC            RS232 data input (true). 10k pullup to 4V
                 Inverted RS232 data out (to inverting buffer like MAX232)
8  +4.4V out     Leave open

9  0V

10 PGM

11 MOD TXD

12 MOD RXD

13 MOD NC

BHX2s on both ends should be configured to required operating frequency using
GOCHAN command before starting to use the internal 1200 baud modem, because the
P1-P3 pins will be used as Modem Data pins and the modem will operate on the last
serially selected channel after SETMOD command is used to enable the Modem.

                      TXE (MOD TX_ON) (1)                           Serial COM Port
                          TXD (MOD NC) (2)
                                                   SW1                   1  RXD
                         AF in (MOD NC) (3)                 VDD     62      TXD
                                         RSSI (4)                   73
                                                                    8       SGD
                          SQF (MOD NC) (5)
                                     AF out (6)                         4
                                                                    9
                          RXD (MOD NC) (7)
                                                                        5
                 BHX2+4.4V out (8)
                                       GND (9)
                                     PGM (10)
                         P1 (MOD TXD) (11)
                         P2 (MOD RXD) (12)
                          P3 (MOD NC) (13)

                                                                                                 RS232 driver

                               Figure 6: BHX2 interfaced to PC serial port in modem mode

Note:
Baud rate used for Modem is half that of used for serial configuration. Attached RS232
devices should be set with the following:

         1200bps, 8 Data bits, No Parity, 1/2 stop bits, no flow control

TXD (Pin 3) of a Serial Port can be switched from PGM (Pin C10) to MOD TXD (Pin
C11) with no RS232 driver in between. However, MOD RXD (Pin C12) requires an
RS232 line driver before it can be connected to RXD (pin 2) of a serial port. Some of
the RS232 line drivers can be powered from the regulated +4.4V out (Pin C8).

Radiometrix Ltd                                    BHX2 Data Sheet                   page 7
Condensed specifications

Frequency                     458.5-459.1MHz (any 5MHz band from 420-480MHz)
                              and any 3MHz band from 210 270MHz
         Frequency stability  +/- 1.5kHz
         Channel spacing      25kHz (12.5kHz by special order)
         Number of channels   128 channels controlled via RS232 interface (8 parallel
                              selected)
Transmit
Output power                  +27dBm (500mW) 1dB
TX on switching time          50 ms
Modulation type               FM, FSK (F1D, F3D)
TX modulation bandwidth       DC 3kHz
Adjacent channel TX power     -37dBm
Inputs                        analogue, data (CMOS/TTL compatible)

Receive                       -118dBm for 12 dB SINAD
                              -70dB
Sensitivity                   -85dB
     image / spurious         <-65dB (Tested per. ETSI EN 301 489-3)
     blocking                 RSSI, carrier detect, audio, data
     adjacent channel         Compliant with ETSI EN 300 220-3 and EN 301 489-3
                              28ms (no noise mute)
Outputs                       45ms (with noise mute)
Spurious radiations           50ms (with or without mute)
Power on to valid audio
Power on to valid audio
Power on to stable data out
(50:50 mark / space)

Supply           Voltage      5.5 - 15V (+5V regulated version available)
                 Current      350mA nominal transmit
                              30mA receive

Interface

                 user         13pin 0.1" pitch molex
                 Power
                 RF           2pin 0.1" pitch molex
                              3pin 0.1" pitch molex
Recommended PCB hole size     or SMA (long, bulkhead mounted type) or MCX
Size
                              1.2mm (min.)
                              85 x 39 x 13 mm Case only (RF pins version)
                              92 x 39 x 13mm (including MCX)
                              105 x 39 x 13mm (including SMA)

Operating temperature         -20 to +60 C (Storage -30 to +70 C)
Intended approval             ETSI Radio standard EN 300 220-3 and EMC standard EN
                              301 489-3

Notes: 1.The data slicer cannot be depended upon for data waveform frequencies below 250Hz

        2. When RX is on and a transmitter keys up, again a 50ms period is required to
          stabilise data output mark/space. i.e. allow at least 50ms of preamble

Radiometrix Ltd               BHX2 Data Sheet                                           page 8
                  Radiometrix Ltd

                        Hartcran House
                       231 Kenton Lane
                      Harrow, Middlesex

                            HA3 8RP
                           ENGLAND
                  Tel: +44 (0) 20 8909 9595
                  Fax: +44 (0) 20 8909 2233
                   sales@radiometrix.com
                    www.radiometrix.com

Copyright notice

   This product data sheet is the original work and copyrighted property of Radiometrix Ltd. Reproduction
   in whole or in part must give clear acknowledgement to the copyright owner.

Limitation of liability

   The information furnished by Radiometrix Ltd is believed to be accurate and reliable. Radiometrix Ltd
   reserves the right to make changes or improvements in the design, specification or manufacture of its
   subassembly products without notice. Radiometrix Ltd does not assume any liability arising from the
   application or use of any product or circuit described herein, nor for any infringements of patents or other
   rights of third parties which may result from the use of its products. This data sheet neither states nor
   implies warranty of any kind, including fitness for any particular application. These radio devices may be
   subject to radio interference and may not function as intended if interference is present. We do NOT
   recommend their use for life critical applications.
   The Intrastat commodity code for all our modules is: 8542 6000

R&TTE Directive

After 7 April 2001 the manufacturer can only place finished product on the market under the provisions of the
R&TTE Directive. Equipment within the scope of the R&TTE Directive may demonstrate compliance to the
essential requirements specified in Article 3 of the Directive, as appropriate to the particular equipment.
Further details are available on The Office of Communications (Ofcom) web site:

      http://www.ofcom.org.uk/radiocomms/ifi/

Information Requests                       European Radiocommunications Office (ERO)
Ofcom                                      Peblingehus
Riverside House                            Nansensgade 19
2a Southwark Bridge Road                   DK 1366 Copenhagen
London SE1 9HA                             Tel. +45 33896300
Tel: +44 (0)845 456 3000 or 020 7981 3040  Fax +45 33896330
Fax: +44 (0)20 7783 4033                   ero@ero.dk
information.requests@ofcom.org.uk          www.ero.dk
This datasheet has been downloaded from:
             www.EEworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company

BHX2-458-5-SMA器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved