AZ7420器件文档内容

                                                                                                                                                                '06'07

                                                                                                                                                Limit Switches

                                                                                                               Limit Switches '06'07

Please contact ..........  These materials are printed on ECF pulp.                                            Matsushita Electric Works, Ltd.
                           These materials are printed with earth-friendly vegetable-based (soybean oil) ink.
ARCT1B272E 200609-1YT
                                   Matsushita Electric Works, Ltd.

                                              Automation Controls Business Unit
                                                Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan
                                                Telephone: +81-6-6908-1050 Facsimile: +81-6-6908-5781

                                              http://www.nais-e.com/

                           All Rights Reserved 2006 COPYRIGHT Matsushita Electric Works, Ltd.                                                                 Limit Switches
                                                                                                                                                                ARCT1B272E '06.9
                           Specifications are subject to change without notice.  Printed in Japan.
                                                                                                                                                                                         Matsushita Electric Works, Ltd.
                                                      COMPACT SIZE                      ML (AZ7)
                                                     LIMIT SWITCHES                  Limit Switches

Terminal mold types (epoxy-sealed terminal type) also available.

                        Standard type      FEATURES                                  4. The switch itself is constructed to
                     (Short roller lever)                                            be dust-proof and oil resistant
                                           1. Long life                              The switch itself is closed flush with the
RoHS Directive compatibility information   High efficiency coil spring switching     diaphragm and the compressed rubber
       http://www.nais-e.com/              mechanism for long life: More than 107    ring, so that the terminal mold type
                                           mechanical operations.                    (epoxy-sealed terminal type) is perfectly
                                           2. Great mechanical strength while        flush with the terminal parts.
                                           being compact and lightweight
                                           The attachment pitch is 25.4mm            TYPICAL APPLICATIONS
                                           (1.000inch), same as for the Z basic
                                           model microswitch. Also, the outer cover  Used in sequence control of food pro-
                                           cap uses a strong plastic with excellent  cessing machines, automatic packaging
                                           mechanical characteristics. An M4 bolt    machines, conveyers, and processors.
                                           can be used for the attachment.           Ideal for light industry machinery when
                                           3. The overtravel (O.T.) is large with    installation pace is limited and a protec-
                                           great shock absorption                    tive construction is sought.

PRODUCT TYPE                                                                   2. Terminal mold type (epoxy-sealed terminal type)

1. Standard type

                       Actuator            Part No.                                                              Cord outlet direction
Short push plunger                         AZ7100
Push plunger                               AZ7110                                                Actuator        N.C.              COM
Hinge lever                                AZ7120
Roller lever                               AZ7121                              Short push plunger                        Part No.
One-way roller lever                       AZ7124                              Push plunger
Hinge short lever                          AZ7140                              Hinge lever                       AZ7400            AZ7401
Short roller lever                         AZ7141                              Roller lever
One-way short roller lever                 AZ7144                              One-way roller lever              AZ7405            AZ7406
Panel mount push plunger                   AZ7310                              Hinge short lever
Panel mount roller plunger                 AZ7311                              Short roller lever                AZ7410            AZ7411
Panel mount cross roller plunger           AZ7312                              One-way short roller lever
Flexible rod                               AZ7166                              Panel mount push plunger          AZ7415            AZ7416
                                                                               Panel mount roller plunger
                                                                               Panel mount cross roller plunger  AZ7420            AZ7421
                                                                               Flexible rod
                                                                                                                 AZ7425            AZ7426

                                                                                                                 AZ7430            AZ7431

                                                                                                                 AZ7435            AZ7436

                                                                                                                 AZ7440            AZ7441

                                                                                                                 AZ7445            AZ7446

Notes) 1. When ordering an overseas-specified product,refer to the foreign                                       AZ7450            AZ7451
             standards overview.
                                                                                                                 AZ7460            AZ7461
          2. Cadmium free contact types are available on a custom-made basis.
             Please add an "F" to the end of the part number when ordering.

                                                                                                                                           33
ML (AZ7)

FOREIGN STANDARDS                                                         Applicable product                                                  Part No.
                                                                                                                                  Order by standard part No.
                            Standards                       File No.          : E122222
                                 UL
                                                            Ratings           : 10A 250V AC
                                C-UL
                                                            Product type : Standard type only
                                TV
                                                            File No.          : E122222

                                                            Ratings           : 10A 250V AC

                                                            Product type : Standard type only

                                                            File No.          : J9551204

                                                            Ratings           : AC-15 2A/250V~

                                                            Product type : Standard type only

SPECIFICATIONS                                Load   Resistive load (cos]1)         Inductive load (cos]0.4)                      Motor or lamp load

1. Rating                                                         10A                              6A         N.C. contact                                    N.O. contact
                                                                  10A                              4A
Rated control voltage                                             0.4A                           0.05A                      3A                                         1.5A
                             125V AC
                             250V AC                                                                                        1.5A                                       1A
                             115V DC
                                                                                                                                                                      

2.Characteristics

Contact arrangement                                                       1 Form C
Initial contact resistance, max.                                          15m* (By voltage drop 6 to 8V DC at rated current)
Contact material                                                          AgCdO contact
Initial insulation resistance (At 500V DC)                                Min. 100 M
                                                                          1,500 Vrms for 1 min Between non-consecutive terminals
Initial breakdown voltage                                                 2,000 Vrms for 1 min Between dead metal parts and each terminal
                                                                          2,000 Vrms for 1 min Between ground and each terminal
Shock resistance           In the free position                           Max. 98m/s2 {10G}
                           In the full operating position                 Max. 294m/s2 {30G}
                                                                          55 Hz, double amplitude of 1.5 mm
Vibration resistance                                                      107 (at 50 cpm)
                                                                          2  105 (at 20 cpm)
Expected life              Mechanical                                     20 to +60C 4 to +140F/Max. 95% R.H. (at 20C 68F)
(Min. operation)           Electrical                                     120 cpm

Ambient temperature/Ambient humidity

Max. operating speed

* The resistance of a copper wire is not included.

3.EN60947-5-1 performance                                                Rating                                                 DATA
                                                                        250VAC
                                Item                                                                                            1. Life curve
Rated insulation voltage (Ui)                                           2.5kV
Rated impulse withstand voltage (Uimp)                                  2.5kV                                                          108
Switching over voltage                                                    10A
Rated enclosed thermal current (Ithe)                                    100A                                                    Operations (104)  107
Conditional short-circuit current                                     10A fuse
Short-circuit protection device                                     IP64 (switch)                                                                  106       125V AC cos  1
Protective construction
Pollution degree                                                           3

4. Operating characteristics                                                                                                                        105

          Characteristics O.F. (N{gf})        R.F. (N{gf})   Pretravel     Movement      Overtravel     Operating Position                                          5         10
                                     max.         min.      (P.T.), max.   Differential  (O.T.), min.     (O.P.) mm inch
Actuator                                                                  (M.D.), max.                                                                        Load current (A)
                                              0.98 {100}      mm inch       mm inch       mm inch      300.8 1.181.031
                                              0.98 {100}                                               441.2 1.732.047
Short push plunger                5.88 {600}   0.39 {40}    2.0 .079 0.8 .031 0.8 .031                 252.0 .984.079
Push plunger                      5.88 {600}   0.49 {50}                                               401.9 1.575.75
Hinge lever                       1.47 {150}   0.59 {60}    2.0 .079 0.8 .031 5.0 .197                 502.0 1.969.079
Roller lever                      1.77 {180}   0.59 {60}                                               251.3 .984.051
One-way roller lever              1.96 {200}   0.78 {80}    13.5 .531 3.2 .126 4.0 .157                401.6 1.575.063        WIRING DIAGRAM
Hinge short lever                 2.16 {200}  0.98 {100}                                               501.6 1.969.063
Short roller lever                2.35 {240}  0.98 {100}    11.0 .433 2.4 .094 3.0 .118                21.80.8 .858.031                              Circuit
One-way short roller lever        2.75 {280}  0.98 {100}                                               33.31.2 1.311.047
Panel mount push plunger          5.88 {600}  0.98 {100}    11.0 .433 2.4 .094 3.0 .118                33.31.2 1.311.047                                 ML
Panel mount roller plunger        5.88 {600}                                                           36 1.417 (T.T.)                                                                 COM
Panel mount cross roller plunger  5.88 {600}               8.5 .335 2.0 .079 2.5 .098                                                                                                 N.C.
Flexible rod                      1.18 {120}                                                                                                                                           N.O.
                                                            6.5 .256 1.5 .059 2.0 .079
                                                                                                                                                    Terminal
                                                            6.5 .256 1.5 .059 2.0 .079

                                                            2.0 .079 0.8 .031 6.0 .236

                                                            2.0 .079 0.8 .031 6.0 .236

                                                            2.0 .079 0.8 .031 6.0 .236

                                                            25 .984                     11 .433

Note) For the operating characteristics, refer to the TECHNICAL INFORMATION.

5. Protective characteristics                                                                                                                            COM  N.O.            N.C.

Protective construction               Standard type               Terminal mold type                                                                          Standard type
            IEC                                             (Epoxy-sealed terminal type)
            IP60                              
            IP64                                                            
                                                                              

34
DIMENSIONS                                                                                                                                                                                                                              ML (AZ7)

Short push plunger                                                                                                                                                                                                                                     mm inch

                                                                                                                                        Push plunger

                      AZ7100                                                                                                                                                                AZ7110

                                                                                                                                                                                                   23.30.3               (P.T.) 2 max.                 12 dia.
                                                                                                                                                                                                  .917.012                     .079                   .472

                                 23.30.3                                                  (P.T.) 2 max.                       12 dia.                                                                                                         8 dia.
                                .917.012                                                        .079                         .472                                                                                                           .315

                          16 dia.                                                                                     7 dia.
                          .630                                                                                      .276

                                                                                                     (O.P.)                                                                                 16 dia.                  (25)   (O.P.)
                                                                                            (25) 300.8                                                                                     .630                    (.984)
                                                                                           (.984) 1.181.031                                                                                                                441.2
                                                                                                                                                                                                                            1.732.047

                                                                                             170.8                                                                                                                   170.8
                                                                                           .669.031                                                                                                                .669.031

                                                                25.40.15  14.3            4.20.2 dia.                                                                                     25.40.15                     4.20.2 dia.
                                                                  1 inch   .563                                                                                                               1 inch
                                                                                                                           21.4                                                               540.2          14.3
                                                                  540.2                                                                                                                                      .563                           21.4

               16.5 max.  2.126.008                                                                                       .843                                                  16.5 max.  2.126.008                                       .843
                                                                                                                                                                                 .650
               .650
                                                                                                                                        Roller lever
                                                                                                                                                                                                                    General tolerance: 0.4 .016

Hinge lever

                     AZ7120                                                                                                                                                                 AZ7121

                                                                                                                      8.50.1                                                               48.351.0               (P.T.) 11.0 max.         8.0
                                                                                                                      .335.004                                                             1.904.039                       .433            .315

                                                                                  63.51.0                     (P.T.) 13.5 max.                                                                                                                              12.5 dia.
                                                                                 2.500.039                             .531                                                                                                                                 .492

                                                                                                                (O.P.)                                                                                                (O.P.)
                                                                                                                 252.0
                                                                                                               .984.079                                                                                               401.9
                                                                                                                                                                                                                    1.575.075

                                                                                                                 170.8                                                                                                170.8
                                                                                                               .669.031                                                                                             .669.031

                                                                25.40.15                  14.3       4.20.2 dia.                                                                          25.40.15   14.3        4.20.2 dia.
                                                                  1 inch                   .563                                                                                               1 inch    .563
                                                                                                                                                                                                                                                       21.4
                                                                  540.2                                                         21.4                                                         540.2                                                   .843
                                                                                                                                                                                            2.126.008
                                                     16.5 max.  2.126.008                                                       .843                                    16.5 max.                                     General tolerance: 0.4 .016
                                                     .650                                                                                                                .650

One-way roller lever                                                                                                                   Hinge short lever

                      AZ7124                                                                                                                                                                AZ7140

                                                48.351.0                                             UNOPERATING                                                                                                              8.50.1
                                               1.904.039                                                                                                                                                                      .335.004
                      OPERATING DIRECTION                                                             DIRECTION            8.0

                                                              max                                                          .315

                                                                           aSnwiglveel90                      12.5 dia.                                                                                 39.21.0
                                                                                                                                                                                                        1.543.039
                                                                                                      10       .492                                                                                                       (P.T.) 8.5 max.
                                                                                                      .394 (F.P.)                                                                                                                 .335

                                                                                                      (O.P.)   572.0
                                                                                                       502.0  2.244.079

                                                                                                 1.969.079

                                                                                                                                                                                                                           (O.P.)

                                                                                                                                                                                                                           251.3
                                                                                                                                                                                                                          .984.051

                                                                                                        170.8                                                                                                             170.8
                                                                                                      .669.031                                                                                                           .669.031

                                                                25.40.15   14.3                 4.20.2 dia.                                                                                          25.40.15               4.20.2 dia.
                                                                  1 inch    .563                                                                                                                          1 inch
                                                                  540.2                                                   21.4                                                                          540.2     14.3

               16.5 max.                                        2.126.008                                                 .843                                                                        2.126.008   .563                           21.4

               .650                                                                                                                                     16.5 max.                                                                                  .843
                                                                                                                                                        .650
                                                                                                                                                                                                                    General tolerance: 0.4 .016

                                                                                                                                                                                                                                                                 35
ML (AZ7)                                                                                                         One-way short roller lever                                                                                       mm inch

Short roller lever

                                   AZ7141                                                                                                               AZ7144

                                                                                                                                                                              30.21.0               UNOPERATING
                                                                                                                                                                            1.189.039
                                                                                                                                                   OPERATING DIRECTIONmax                            DIRECTION                     8.0

                                                                             (P.T.) 6.5 max.                                                                                                                                       .315
                                                                                      .256
                                                   30.21.0                                      8.0                                                                  aSnwiglveel90
                                                  1.189.039                                     .315

                                                                                                                 12.5 dia.                                                                                              12.5 dia.
                                                                                                                 .492
                                                                                                                                                                                                    10 (F.P.)           .492

                                                                                                                                                                                                    .394 551.6
                                                                                                                                                                                                     2.165.063

                                                                               (O.P.)                                                                                                                 (O.P.)
                                                                               401.6                                                                                                                 501.6
                                                                             1.575.063                                                                                                             1.969.063

                                                                                170.8                                                                                                                170.8
                                                                              .669.031                                                                                                             .669.031
                                                                             4.20.2 dia.
                                                  25.40.15                                                                                                            25.40.15        14.3         4.20.2 dia.
                                                     1 inch                                                                                                               1 inch
                                                    540.2        14.3                                                                                                   540.2         .563                                       21.4
                                                                  .563
                                                  2.126.008                                     21.4                                                                  2.126.008
                                   16.5 max.                                                     .843                                              16.5 max.                                                                       .843
                                   .650                                                                                                            .650
                                                                                                                                                                                                  General tolerance: 0.4 .016

Panel mount push plunger                                                                                       Panel mount roller planger

                                   AZ7310                                                                                                          AZ7311

                                                                                                         17                                         23.30.5                          (P.T.) 2 max.                     3.8
                                                                                                        .669                                       .917.020                                .079                        .150

                           M12(P=1.0)          23.30.5            (P.T.) 2 max.                8 dia.                                                                                                                               12.5 dia.
                                              .917.020                  .079                 .315                                                                                                                                   .492
    2-panel mounting nut
    Thickness 3.2 .126                                            (O.P.)                                                               M12(P=1.0)             15.3                    (O.P.)
    Length of opposite side 17 .669                               21.80.8
                                                                  .858.031                                     2-panel mounting nut                          .602                    33.31.2
             Teethed washer                                                                                     Thickness 3.2 .126
                                                                                                                Length of opposite side 17 .669                                       1.311.047

                                                                                                                         Teethed washer

                                                                      (25)                                                                                                             (25)
                                                                     (.984)                                                                                                           (.984)

                                                                    170.8                                                                                                              170.8
                                                                  .669.031                                                                                                           .669.031

                                              25.40.15   14.3       4.20.2 dia.                                                                  25.40.15                          4.20.2 dia.
                                                1 inch    .563                                                                                       1 inch
                                                540.2                                           21.4                                                540.2            14.3
                                              2.126.008                                         .843                                                                  .563                                             21.4

                                   16.5 max.                                                                                        16.5 max.      2.126.008                                                           .843
                                   .650
                                                                                                                                    .650                                                          General tolerance: 0.4 .016

Panel mount cross roller planger                                                                               Flexible rod

                                                                                                                                                   Total travel (36)

                                                                                                                                                              (1.417)
                                                                                                                                                   Pretravel (25)
                                                                                                                                                                       23.3
                                                                                                                                                              (.984)
                                                                                                                                                                       .917

                                   AZ7312                                                                                                                                                                                               24.5
                                                                                                                                                                                                                                        .965

                                                                                                                                                                                                                                    (Range of
                                                                                                                                                                                                                                    operating
                                                                                                                                                                                                                                    position)

                                    23.30.5              (P.T.) 2 max.                          12.5 dia.3.8                                                                                        107.51.5                          16 dia.
                                   .917.020                    .079                             .492 dia..150                                                                                       4.232.059                         .630

                       M12(P=1.0)           15.3        (O.P.)                                                                                                                                       17.5
                                            .602         33.31.2                                                                                                                                    .689
2-panel mounting nut                                    1.311.047
Thickness 3.2 .126
Length of opposite side 17 .669

         Teethed washer

                                                           (25)                                                                                                                                       24
                                                          (.984)                                                                                                                                     .945

                                                            170.8                                                                                                                                     170.8
                                                          .669.031                                                                                                                                  .669.031

                                   25.40.15      14.3    4.20.2 dia.                                                                                                 25.40.15                          4.20.2 dia.
                                     1 inch       .563                                                                                                                    1 inch              14.3
                                     540.2                                                                                                                              540.2
                                                                                           21.4                             AZ7166                                                            .563                            21.4
                                                                                           .843                                                                        2.126.008
    16.5 max.                      2.126.008                                                                                             16.5 max.                                                                           .843
    .650                                                                                                                                  .650
                                                                                                                                                                                                  General tolerance: 0.4 .016

36
Terminal Mold Type (Epoxy-Sealed Terminal Type)                                                                 ML (AZ7)

The waterproof type (IP64) has its terminals sealed with epoxy resin.                               Epoxy resin filled up for reliable watertightness
1. Type of product                                                                                  and heat resistance.
All the standard type have this epoxy-sealed
terminal types.                                                                                                                         3-core vinyl cabtire cable
2. Appearance
The dimensions are the same as
those of the standard type.
The cord outlet is located either at
the N.C. or COM side.
The cord is 1 m 3.281ft. long.

Cord outlet direction: N.C.                    Cord outlet direction: COM

                                                                                              COM terminal
                                                                                                            N.O. terminal
                                                                                                                            N.C. terminal

                                                                                              Cord specifications

                                                                                              Type  Vinyl cabtire cable (VCT)(3 1.25mm2)

                                                                                              Cord length 1m 3.281ft.

                                                                                                                 Black: COM
                                                                                              Lead colors Red: N.C.

                                                                                                                 White: N.O.

CAUTIONS                                       9) When used outdoors (in places where         N.C.                                         COM
                                               there is exposure to direct sunlight or
1. Ambient conditions                          rain such as in multistory car parks) or in    Side mounting
1) When the switch is to be used in            environments where ozone is generated,         To mount onto a side, use M4 screws
places where oil or is abundant, bore a        the influence of these environments may        with washers and secure it firmly. The
drain hole in the bottom of the terminal       cause deterioration of the rubber materi-      tightening torque should be 1.18 to 1.47
cover.                                         al. Please consult us if you intend to use     Nm (12 to 15 kgcm).
2) Avoid places where highly acid or           a switch in environments such as these.         Panel mounting
alkaline fluids are used or high tempera-      10) Do not store in places where organic
tures prevail.                                 gas might be generated or in places of          (panel mount plunger type)
3) This model uses silver terminals.           high dust content or high humidity.            When installing the panel mounting type
Therefore, if used at relatively low fre-      2.Mounting and wiring                          onto a panel, the tightening torque for
quencies for long periods of time, or if       1) Remove the terminal cover with a v          the hex. nut should be 7.84 Nm (80
used with very small loads, the oxidiza-       driver. Insert the lead wire through the       kgcm).
tion that forms on the contact surfaces        knock-out of the terminal cover.                For terminal mold types (epoxy-sealed
will not wear away and eventually cause        (The terminal cover of the epoxy-sealed        terminal types), there are two types by
improper contact. For such applications,       terminal type is filled with resin. It cannot  the cord outlet direction; N.C. side and
use limit switches with gold/metal con-        be removed.)                                   COM side.
tacts (e.g. VL limit switches) or ones                                                        3. Flexible rod
meant for small loads (e.g. HL limit                           Standard type                  1) Put the detective object to the tip of
switches).                                                                                    plastic part.
4) This switch is not designed for under-      2) Connect the lead wire to the terminal.      2) Avoid pushing the tip of actuating
water use. Do not use the unit under-          When connecting the terminals with the         spring in the direction of axis. In the
water.                                         fasten lug, those with the insulation          places of oil or water splashes and much
5) To improve reliability during actual        sleeve are recommended.                        dust area, use the limit switch with keep-
use, it is recommended that the opera-         Tightening torque: 1.18 to 1.47 Nm {12        ing the actuating spring in the vertical
tion be checked under installation condi-      to 15 kgcm}                                   direction.
tions.                                         3) The terminal cover can be mounted in
6) If OT is too big, the life of limit switch  both directions.                                                                                  37
will be shortened switching friction. Use it    In this case, fasten the terminal cover in
with enough margin of OT. 70% of OT            the opposite direction.
standard value will be good for use.
7) Do not use the switch in a silicon
atmosphere. Case should be taken
where organic silicon rubber, adhesive,
sealing material, oil, grease or lead wire
generates silicon.
8) Avoid use in excessively dusty envi-
ronments where actuator operation
would be hindered.
SELECTOR CHART

Classification                                                 Subminiature size                           HL (AZH)                               HL (AZH)                         Compact size                              ML (AZ7)                      ML (AZ7)
Product name                                                                                            Limit Switches                         Limit Switches                                                             Limit Switches               Limit Switches
                                                                 SL (AZ3) Micro                         (Die cast case)                        (Die cast case)                        HL (AZH)                                                     (Epoxy-Sealed terminal type)
                                                                  Limit Switches                                                                                                   Limit Switches                           (standard)
                                                                                                                                                                                   (Plastic case)

Appearance

Head code                                                                                                                   AZH20                                                                      AZH10

                                                                                      AZ3                                   22                                      AZH23                                 12                                  AZ7                      AZ7

                                                                A limit switch with                     High sealability that                High sealability that             Bifurcated type                      Switches installed An ML compact limit
                                                                                                                                                satisfies IEC IP67.                 available.
                                                               high-density mounting satisfies IEC IP67.                                                                                                                  with both economical switch with an
                                                                                                                                                Less wiring, less                  Perfect for applica-
                                                               that improves stroke Wiring is screw-ter-                                      installation connec-                tions that prioritize                 and compact Z-basic epoxy-sealed case
                                                                                                                                                tor type.                           economy.
Feature                                                        capacity through an minal type.                                                                                                                            microswitches and that completely
                                                                                                                                                LED lamp type also                             
                                                               O.T. absorption-type Bifurcated type also                                      available.                                                                limit switch protective encloses the

                                                               spring.                                  available.                                                                                                        construction.            terminal.

                                                                LED lamp type also                                                                                                                                        Coil spring system

                                                               available.                                                                                                                                                 provides long life.

With lamps Protective construction  Dust-proof type  IP60      Rubber-cover type Socket with cord type                                                                                                                                             
                                                                             

                                    Abrasion-proof type IP64                                                                                                                                                                                     

                                    Surge-proof type IP65                                                                                                                                                                                                 

                                    Corrosion-proof type IP67                                                                                                                                                                                             

                                    Oil-resistant type                                                                                                                                                                                          

                                    Neon                                                                                                                                                                                                                

                                    LED                                                                                                       (with LED lamps)                                                                                         

                                                                4A250V AC                               [Standard type]     [Bifurcated type]  [Bifurcated type]                   [Standard type]     [Bifurcated type]  10A250V AC               10A250V AC
                                                                4A125V AC                               5A125V AC           0.1A125V AC                                            5A125V AC           0.1A125V AC        10A125V AC               10A125V AC
Ratings                                                          4A30V DC                               5A250V AC           0.1A8V DC          without LEDlamps     with LEDlamps  5A250V AC           0.1A8V DC          0.4A115V DC              0.4A115V DC
(load resistance)                                              0.1A 125V DC                             5A8V DC             0.1A14V DC         0.1A125V AC          0.1A24V AC     5A8V DC             0.1A14V DC
                                                                                                        5A14V DC            0.1A30V DC         0.1A8V DC                           5A14V DC            0.1A30V DC                107                      107
                                                                                                        5A30V DC                               0.1A14V DC                          5A30V DC                                    2x105                    2x105
                                                                                                        0.5A125V DC                            0.1A30V DC                          0.5A125V DC
                                                                                                        0.25A250V DC                                                               0.25A250V DC

Life                                      Mechanical                    107                             107                                           107                                 107
                                                                        105
(Min.ope.) Electrical                                                                                   5x105                                         5x105                               5x105

Operating force                                                 0. 98N {100gf}                           2.45N {250gf}                          2.45N {250gf}                                                             1.47N {150gf}, 1.77N {180gf}, 1.47N {150gf}, 1.77N {180gf},
(max.)                                                          1. 96N {200gf}                          3. 92N {400gf}                          3.92N {400gf}
(hinge lever type)                                             (short lever type)                       11.8N {1,200gf}                        11.8N {1,200gf}                     2.45N {250gf}                          1.96N {200gf}, 2.16N {220gf}, 1.96N {200gf}, 2.16N {220gf},
                                                                2. 94N {300gf}                           (Plunger type)                         (Plunger type)                     3. 92N {400gf}
                                                                                                                                                                                                                          2.35N {240gf}, 2.75N {280gf}, 2.35N {240gf}, 2.75N {280gf},

                                                                                                                                                                                                                          5.88N {600gf} max.       5.88N {600gf} max.

Available
actuators

Terminals                                                       Rubber cover (Solder                     Screw terminal                       Connector terminal                    Screw terminal                          Screw terminal        Vinyl cabtire cable
                                                                and quick connect                                                                                                                                                                      (1m 3.281ft)
                                                                (#110) terminal)                            Cabtire code                           Cabtire code                        Cabtire code                           Cabtire cable
                                                                                                                                                                                                                                                      Cabtire cable
                                                                Socket with cord                        33mm 1.299inch                         33mm 1.299inch                      33mm 1.299inch                        25.4mm 1.000inch
                                                                                                             (M4 screw)                             (M4 screw)                          (M4 screw)                             (M4 screw)          25.4mm 1.000inch
Wiring                                                         Cabtire code                                                                                                                                                                            (M4 screw)
                                                                                                        UL, CSA, TV, CE                       UL, CSA, TV, CE                    UL, CSA, TV, CE                       UL, C-UL, TV, CE
Mounting pitch                                                 Cross-angled wiring                               P.18                                   P.18                                P.18                                    P.33                     
(Applicable screw)                                                  28  14mm                                                                                                                                                                                P.33

Available standards                                             1.102  .551inch
Page                                                                (M4 screw)

                                                                      UL, CSA

                                                                         P.13

Note: Excludes limit switch replacement parts

Actuators

                                    Push plunger               Roller plunger                           Cross-roller plunger                   Roller arm                          Adjustable roller arm                  Adjustable rod           Fork

         Spring wire                                           Flexible rod                                Hinge lever                         Roller lever                        One-way roller lever                   Roller lever
                                                                                                        Short
2                                                                                                                                              Short                               Short
                                                                                                                     Long
                                                                                                                                                                 Long                               Long
Classification                                            Subminiature size                            Compact size vertical type                              Vertical type                            Touch type                       Door switch
Product name                                                  vertical type
                                                                                                                                                                     AZ5                             VL-T Mini Touch
                                                          QL (AZ4) Micro                       DL (AZD1) Mini            VL (AZ8) Mini                         Limit Switches                         Limit Switches        Compact            Magnelimit
                                                          Limit Switches                       Limit Switches            Limit Switches                                                                                    Magnelimit

Appearance

Head code                                                                           AZ4                         AZD1                         AZ8                                   AZ5                     AZ84                          AZC3                AZC1

                                                          A subminiature, highly accu- Excellent safety even if the   In addition to the                   Built-in dedicated                   Operate just by      Secured by magnet Secured by magnet
                                                                                                                          characteristics of                    circuit breaker                       touching lightly.
                                                          rate limit switch with built-in contact point is welded,        stand mounted limit                   (1 Form A                                                   Built-in switch detection Built-in switch detection
                                                                                                                          switches, is com-                     1 Form B).                            Comes with sen-
                                                          environment-proof functions. due to the forced contact          pact, easily instal-                                                        sitivity adjustment
                                                                                                                          lable, highly reli-                   Different types of                   function and indi-
Feature                                                    Cord extraction can be             opening mechanism.         able, lightweight,                    actuator avail-                       cates operations.    Dual-role switch in Dual-role switch in
    Dust-proof type                                                                                                       and economical.                       able.
                                                          changed in four directions, Block mount system makes                                                                                     VL type touch       one unit.           one unit.
                                                                                                                                                                                                      limit switch
                                                          due to the dedicated L socket. parts replacement easy.                                                                                                            Safe design prevents Construction possi-
                                                                                                                                                                                                               
                                                          LED lamp can also be                Conforms to DIN stan-                                                                                                     operator making     ble with 100V AC

                                                          attached.                            dards.                                                                                                                      errors.             power.

With lamps Protective construction        IP60            L socket type Socket with cord type                                                                                                                                                           
                                                                           

                                    Abrasion-proof type IP64                                                                                                                                                                                            

                                    Surge-proof type IP65                                                                                                                                                                                           

                                    Corrosion-proof type IP67                                                                                                                                                          1)                             

                                    Oil-resistant type                                                                                                                                                                                                

                                    Neon                                                                                                                                                                                                          

                                    LED                                                                                                                                                                                                             

Ratings                                                   5A250V AC                            6A250V AC                 [Standard type]     [With lamp type]  [Standard type]     [With lamp type]   Input voltage        2)                  5A 125V AC
(load resistance)                                                                              6A380V AC                 5A250V AC           [Neon lamp type]  10A125V AC          [Neon lamp type]    12-24V DC                               5A 250V AC
                                                                                               5A24V DC                  5A125V AC           5A 240V AC        6A250V AC           10A 125V AC       Output current         5A (2A) 125V AC     5A 30VDC
                                                                                                                         0.4A125V DC         5A 125V AC        2A500V AC           6A 240V AC                               5A (2A) 250V AC
                                                                                                                                             [LED lamp type]   0.8A125V DC         [LED lamp type]       150mA               5A (2A) 30VDC
                                                                                                                                             3A 24V DC                             6A 24V DC

Life                                      Mechanical                 107                               107                  107                                   107                                107                            105                105

(Min.ope.) Electrical                                                3x105                             1.5x105              3x105                                 5x105                                                   5x104                      5x104

Operating force                                              6.86N {700gf}                     6.37N {650gf}               0.88N {90gf},                         1.39N {142gf}                                                               3.43N {350gf}
(max.)                                                       (Plunger type)                    4.90N {500gf}              5.88N {600gf},                       26.67N {2,720gf}
(hinge lever type)                                        1.11N {113gf}, 4.41N {450gf}         3.29N {400gf}              8. 83N {900gf},
                                                                                                                         19.16N {2,000gf}
                                                               (Arm type)

Available
actuators

                                                          L socket (Solderand Screw terminal                                                                                                         Free attachment

Terminals                                                 quick connect                        (Conduit connec-           Screw terminal                        Screw terminal                        Screw terminal       Tab #110 terminal    Screw terminal
                                                                                                                                                                                                                                Lead wire
Wiring                                                    (#110) terminal) tors: PF: 1/2, PG:                               Cabtire cord                         Cabtire cable                         Cabtire cord                              Cabtire cord
                                                                                                                           Cap tire cable                         (wiring type)                        Cabtire cable          Cabtire cord
Mounting pitch                                             Socket with code 13.5 types)                                                                                                                21  56mm                               52mm 2.047inch
(Applicable screw)                                                                                                          21  56mm                            30.2  58.7mm                         827  2.205inch         30mm 1.181inch             (M4)
                                                          Cabtire code                         Cabtire code              .827  2.205inch                       1.189  2.311inch                        (M4 screws)                  (M3)

                                                          14  28mm                             22  (47mm)                   (M4 screws)                           (M5 screws)

                                                          .551  1.102inch .866  1.850inch

                                                          (M4 screws)                          (M4 screws)

Available standards                                              UL, CSA                       UL, C-UL, TV, CE UL, C-UL, TV, CE                                UL                                                      UL, C-UL            UL, C-UL, CE
                                                                                                                                                                                                     P.68                     P.72                   P.74
Page                                                                 P.38                              P.44                 P.52                                  P.61

Notes: 1) Excludes exposed part of terminals, externally mounted components, and magnet catches.
         2) Figures in parentheses ( ) indicate rated current of water-resistant type.

Other listed products

Product name                                                                                   PS Hall Sensors

Appearance

                                                                                                                                                  AN9
                                                                                                          Detector distance 2.5mm .098inch

Feature                                    Magnetic detector type subminiature sensor
                                           Perfect for slide table limiting
                                           Economical price with operating display lamp attached.

Page                                                                                                   P.76

                                                                                                                                                                                                                                                                         3
ACTUATOR SELECTION

   Type  Classification        Pretravel  Overtravel  Operating     Accuracy   Vibration  Characteristics
                                 (P.T.)      (O.T.)   force (O.F.)               shock

         Push plunger type     Small      Medium      Large         Excellent  Excellent  High-level accuracy gives firm detection for position
                                                                                          fixing, etc., by using perpendicular movement.

         Roller plunger type   Small      Medium      Large         Excellent                  Operating range can be widened by mounting
         (includes cross                                                       Excellent accessory actuators like cams, dogs, cylinders, etc.
         roller plunger)
                                                                                               High-level detection for position fixing.

         Roller arm type       Small to   Large       Medium        Good to    Excellent  The stroke in the direction of revolution is large at
                                 large                              excellent             between 45 and 90 and the lever angle can be set
                                                                                          at will to within 360 for easy use. Wide angle type
                                                                                          (large O.T.) available. Can be used for wide-range
                                                                                          position fixing.

         Adjustable roller     Small to   Large       Medium        Good to    Good       Lever length can be altered to allow rough operation
         arm type                large                              excellent             detection using the roller lever characteristics.

         Adjustable rod type Large        Large       Medium        Good       Good       Wide range of operations, and convenient for
                                                                                          uneven mountings. Lightest operation among the
                                                                                          revolving operation type of limit switches. Rod length
                                                                                          is adjustable, and bending is also easy.

         Fork                   Large     Medium      Medium        Good       Excellent  If operated up to 55 position, revolves automatically
                               Medium      Large       Small                              to retain 90 position. Two dog operation enables
         Spring wire and                                                                  recovery operation through single dog, or for any-
         flexible rod                                                                     thing that has caused the roller position to slip.

         Hinge lever type                                           Possible   Possible   Excluding the thread direction, direction can be
                                                                                          adjusted up to 360. Operating power is the lowest
                                                                                          of the limit switches, and is effective in detecting
                                                                                          when direction and conditions are uneven. In order
                                                                                          to absorb the movements after operation in the actu-
                                                                                          ator part, work slippage tolerances are also large.

                               Large      Medium      Small         Possible   Possible   Using a low speed, low torque cam, the lever can
                                                                                          assume various shapes suited to the operation. The
                                                                                          lever is very sturdy.

         Roller lever type     Large      Medium      Small         Possible   Possible   Suited to high speed cams through the attachment
                                                                                          of a hinge roller lever.

         One way roller lever  Medium     Medium      Medium        Possible   Possible   Operation is possible with both hinge lever type and
         type                                                                             one way operation, but the roller will break if operat-
                                                                                          ed in the opposite direction, rendering the unit inop-
                                                                                          erable. Can be used to prevent opposite direction
                                                                                          movement.

         Roller lever type     Medium Medium Medium Possible Possible The roller position can be changed.

4
TECHNICAL INFORMATION

Standard glossary                                                    CONSTRUCTION                                                       OPERATING CHAR-
Fixed rating values                                                 Actuator
                                                                                                                                           ACTERISTICS
  The values that guarantee the stan-                                  This part directly detects movement
  dards for the limit switch characteris-                              of the dog, cam, and so forth in the                              Operating Force (O.F.)
  tics and functions. For example, the                                 operating unit, and transmits external                             The force required to cause contact
  rated current and rated voltage,                                     force to the changeover mechanism,                                 snap-action. It is expressed in terms
  which are preset conditions (load                                    thereby engaging the moveable con-                                 of force applied to the actuator.
  type, current, voltage, frequency,                                   tact and operating the switch.
  etc.)                                                                                                                                  Release Force (R.F.)
                                                                      Headblock                                                          The force to be applied to the actua-
Operating object                                                     An independent part of the actuator                                tor, at the moment contact snaps
  The mechanism and mountings that                                     mechanism of the Limit Switch.                                     back from the operated position to
  operate the limit switch actuator.                                                                                                      unoperated position.
  Used for mechanical operators                                       Wiring vent (cord vent)
  such as cams and dogs.                                               The seal on the wiring at the mouth                               Pretravel (P.T.)
                                                                       of the wiring vent. Also called the                                Distance of the actuator movement
Detective object                                                     conduit vent for the screw hole used                               from free position to operating posi-
  The unit other than mechanical                                       in the wiring.                                                     tion.
  mountings that operate the limit
  switch. Products, parts, jigs, etc.                                 Terminals                                                         Overtravel (O.T.)
                                                                       The part of the wiring work in the                                 The distance which the actuator is
Reaction spring (movable spring)                                     wiring that forms the circuit for elec-                            permitted to travel after actuation
  The mechanical part that switches                                    trical input and output.                                           without any damage to the switching
  the limit switch contact is called                                                                                                      mechanism.
  either the reaction spring or the                                                  Roller                Head block
  moveable spring.                                                   Actuator Arm                                                       Total Travel (T.T.)
                                                                                                                                  Cam     The distance which the actuator is
Contact                                                                                                                       Roller    permitted to travel from free position
  When the counter-spring revolves,                                                                                           Plunger     without any damage to the switching
  power is switched on and off through                                                                                 Reset spring       mechanism.
  the contact between metal parts                                                                                        Pushbutton
                                                                                                                                        Movement Differential (M.D.)
Contact gap                                                                       Front view                         Cord vent          The distance from operating to
  The effective clearance between the                                                        Cam                                          release position of the actuator.
  fixed contact and the moveable con-                                                       Roller
  tact. Also called breaking distance.                                                       Reset spring                               Operating Position (O.P.)
                                                                                           Pushbutton                                     The position of the actuator when the
Contact arrangement                                                                                                                     traveling contact snaps to the fixed
  The construction of the electrical                                 VL limit switch                                                      contact.
  input/output circuit depending on
  use. For example, the following two                                                                                                    Release Position (R.P.)
  applications:                                                                                                                           The position of the actuator when the
                                                                                                                                          traveling contact snaps back from
                                  F                                                                                                       the operating position to its original
                                                                                                                                          position.
                     N.O. N.C. [1 Form C(Single Pole Double Throw)]
                 F                                                                                                                      Free Position (F.P.)
                                                                                                                                          Position of the actuator when no
                                            N.C.                                                                                          force is applied to it.

            COM                                                                                                                                     Free position
N.C.
                                                                                                                                        O. P. Operating position  O. P. Operating position

                                                                                                                                                                  P.T. P.T.

N.O.             [1 Form Z(Double Break Double Make)]                                                                                   O.T.                                       O.T.
                   N.O.                                                                                                                      M.D.                             M.D.

                                                                                                                                              R.P.                           R.P.

Contact type                                                                                                                                                               R.F.
  Used in opposition to a semiconduc-
  tor switch that has switching charac-                                                                                                                  O.F.          R.T.
  teristics. Fulfills switch functions                                                                                                              P.T.          M.D.
  through a mechanical ON/OFF con-
  tact.                                                                                                                                                           O.T.T.F.         T.T.

Terminal mold                                                                                                                         F.P.
  After wiring, the connecting part is                                                                                                                  O.P.
  molding by epoxy resin for water-
  proof, oil-resistant and dust-proof                                                                                                                                        R.P.
  capabilities.
                                                                                                                                                                                Standard position

                                                                                                                                        Note: F.P., O.P., and R.P. are expressed as distances
                                                                                                                                                from the standard position.

                                                                                                                                                                                                   5
TECHNICAL INFORMATION

Glossary relating to the EN60947-5-1

EN60947-5-1                                    Rated impulse withstand voltage         Pollution degree
  EN standard same as IEC947-5-1                  (Uimp)                                   Expresses in levels the environment
                                                  The peak impulse current value           in which the switch is used. The four
Utilization categories                          which enables the switch to resist       levels are shown below.
  The following examples express the              without insulation breakdown.            Limit switches come under contami-
  classification of switches by category                                                   nation level 3.
  of use.                                        Rated enclosed thermal current
                                                  (Ithe)
   Current  Category          Contents            The current value that enables cur-    Pollution                  Contents
     type                                         rent to flow without exceeding the      degree
                                                  specified maximum temperature in                  No contamination or, even if conta-
                      Controls electromagnetic    the recharging contact switch. If the       1     mination is present, only non-con-
                                                  pins are made of brass, the maxi-                 ducting contamination is generated.
   AC       AC-15 loads in excess of 72VA         mum temperature limit is 65C 149F.        2
                                                                                                    Normally, only non-conducting cont-
                      (Volt Amperes.)            Conditional short circuit current           3     amination is generated, but there
                                                  The current the switch can resist           4     remains the possibility of temporary
                      Controls resistance         until the short circuit protection                conducting contamination when the
                                                  device is activated.                              circuit is formed.
   DC       DC-12 loads and semiconductor
                                                 Short circuit protection device                   Conducting contamination is gener-
                      loads.                      A device that protects the switch                 ated, or else dry non-conducting
                                                  from short circuits through a circuit             contamination is generated by cir-
Rated operational voltage (Ue)                  break (breakers, fuses, etc.)                     cuits which can be anticipated.
  The maximum rated voltage for
  switch operation. This must never             Switching overvoltage                             Permanent conducting contamina-
  exceed the maximum ratings insula-              The surge momentarily generated                   tion is generated by dust, rain,
  tion voltage (Ui).                              when a circuit is closed. Must be                 snow, and other conductors.
                                                  lower than the Uimp value.
Rated operational current (Ie)
  The maximum rated current for
  switch operation.

Rated insulation voltage (Ui)
  The maximum rated current value
  which guards the switch's insulation
  functions, forming the parameters for
  the resistance values and the mount-
  ing distance.

6
PROTECTIVE CONSTRUCTION

Protective construction

Expresses the degree of protective construction that guards the level of functionability of the switch against ingress of solid
objects, water, and oil. The standards are IEC529 (IEC: International Electrotechnical Commission) standards. IEC standards
determine the level of protection against both water and solid objects, but not against oil.

Protection against both water and solid objects

IP-                 Level Protection level                                     Protection level and test methods

                    0  --                                                                   No particular protection

                                            Protection against rain fall

                    3 Rain-proof                                                               No damage incurred when sprayed with water
                                               Protection against flying foam                  continuously for 10 minutes at angles of up to 60
                                                                                               from the perpendicular.

                    4 Foam-proof

Protection                                                                                     No damage incurred when sprayed with water
against water                                                                                  continuously for 10 minutes at angles of up to 180
                                                                                               from the perpendicular across a wide area.

                                            Protection against spray

                    5 Spray-proof                       Nozzle radius 6.3mm .248inch
                                                        Water pressure 30kP
                                                                                               No damage incurred when sprayed with a jet of water
                                              3m                                               for 3 minutes from all directions, as per the diagram
                                            9.843ft.                                           on the left.

                                            Protection against waves

                                                      Nozzle radius 12.5mm .492inch
                                                      Water pressure 100kP

                    6 Water proof

                                              3m                                               Water does not invade the interior when sprayed with
                                            9.843ft.                                           a jet of water for 3 minutes from all directions, as per
                                                                                               the diagram on the left.

                                            Protection against corrosion while
                                            immersed in water

                    7  Corrosion-                                              1m
                          proof                                                   3.281ft.

                                                                                               Water does not invade the interior during immersion
                                                                                               for 30 minutes at a depth of 1m 3.281ft..

                    Level Protection level                                     Protection level and test methods

                                            Protection against solid

                                            objects exceeding                   1.0 .039 dia.

                                            1mm .039inch in size.

                    4  --

                                                                                               A hard wire 1mm dia. .039 inch dia. across cannot
                                                                                               penetrate the inside.

Protection against                          Protection against dust
solid objects

                    5  --

                                                                                               The unit is left for 8 hours in an atmosphere in which
                                                                                               2kg of talcum powder per 1m3 is floating. No damage
                                                                                               incurred from talcum powder penetrating the inside.

                                            Protection againt dust
                                            (dust does not penetrate)

                    6 Dust-proof

                                                                                               The unit is left for 8 hours in an atmosphere in which
                                                                                               2kg of talcum powder per 1m3 is floating. The talcum
                                                                                               powder does not penetrate the inside.

Note: 1. All of the tests cited above were conducted with the cord vent (conduit vent) tightly shut.
         2. The above protective constructions are based on IEC standard but major differences may arise due to length of use and operating environment.
             This should be thoroughly discussed and verified.
         3. When the corrosion-proof model is immersed in water for 30 minutes or more, verify that no water has penetrated the inside before use.

                                                                                                                                                          7
CAUTIONS FOR USE

DESIGN OF OPERATING DOG AND OPERATING SPEED

Pay attention to the following points                    3) 0.5m/s ! V&2m/s                                           5) Roller plunger type
when designing the dog for limit switch
operation.                                                                                                                                    
1. Make the dog faceplate as smooth                                             V
as possible.                                                                                                                                       h
2. Adjust both the dog angle and the                                                                            h
set arm angle as below, depending on                                                                         F
the operating speed.
3. The depth (h) of the dog effects the                             o
lifespan of the limit switch. Therefore,
set the depth to a maximum of 80% of                                                                                         Vmax (m/s)         h
the Total Travel (T.T.)
4. The relationship between the speed                                  Vmax (m/s)                                     20    0.5              (0.5 to 0.7) T.T.
of the dog (V = m/s) and the tip angle
() is as follows:                                        40           0.7                                            30    0.25             (0.6 to 0.8) T.T.

1) V&0.2m/s                                              35           0.9                                            Even if overriding the dog, set the for-
                                                                                                                      wards and rearwards motion exactly
                         = 45 to 90                    30           1.3                                            the same, and avoid any settings that
                 V                                                                                                    make the actuator accelerate rapidly
                                                         25           2.0                                            from the dog.
                                                      h                                                               5. Operation speed
                                                         The maximum tolerable speed can be                           1) When the operation (acting and
                                                         extended by further reducing the dog                         reverting) speed is exceedingly slow,
                                                         rise angle from 45 when 0.5m/s !                            switching of the contacts will become
                                                         V&2m/s. It is necessary to set the arm                       unstable and this could cause prob-
                                                         so that the dog's cutting surfaces are                       lems such as failure to make contact
                                                         always parallel ( o = 90 )                                 and welding. As a guide, the speed
                                                                                                                      should be at least 1mm/s.
                                                         4) Overriding the dog (V&0.2m/s)                             2) When the operation (acting and
                                                                                                                      reverting) speed is exceedingly fast,
              Vmax (m/s)                                                                                              be careful because the violent motion
      45          0.2                                                                                                could cause breakage and with
      60          0.1                                                                                             h  increased frequency, contact switching
   60 to 90      0.05                                                                                                will not be able to keep up. As a guide,
                                                                                                                      the switching frequency should be
When V&0.2m/s, set the arm to per-                                     Vmax (m/s)                                     within 20 times per minute.
pendicular and set the arm rise angle
to between 45 and 90. If the dog rise                  45           0.2
angle is reduced, the maximum tolera-
ble speed is increased.                                  60           0.1
As a rule,  = 45 is optimum.
                                                         60 to 90     0.05

2) V&0.5m/s                                              If overriding the dog, set the arm per-
                                                         pendicularly, so that  =45. If the dog
                    = 45                                angle is reduced, the tolerable speed
   V                                                     is increased.

                                         h

              F

    o = 45

Because the arm jiggle is as a mini-
mum at a comparative speed such as
V&0.5m/s, setting both the dog angle
so that it travels perpendicularly and
the arm angle to 45 is optimum.

8
PROTECTION CIRCUIT                                                                                           CAUTIONS FOR USE

1. The ON/OFF circuit for the guidance                      2. Do not connect either irregular poles          3. Avoid circuits where power may find
load may suffer contact damage due to                       or power sources to a switch contact.             a way between the contact points (as
surges or inrushes when the power is                        Power connection examples (irregular              this may cause welding.)
turned either ON or OFF.                                    pole connection)
Consequently, insertion of a protective                                                                                           NO GOOD
circuit as per the following diagram is
recommended, in order to protect the                        NO GOOD
contacts.
                                                                                                  Load
                                                                                                    L

                                                                                                              L  ~         200V
                                                                                                                        ~
        Circuit                    Cautions for use
Limit switch contact                                             Load                                            100V
                                (1) r must be a minimum     GOOD
                                    of 10;                                                        Load
                                                                                                    L         4. Using electronic switch circuits (low
                                (2) When using AC power:                                                      power, low current)
rc        R                        Q Impossible when R                                                        1) Bouncing and chattering are gener-
                                       impedance is large.                                                    ated due to collision between the con-
                                   W Possible when c, r                                                 Load  tacts when the limit switch is switching
                                       impedance is suffi-                 Load connected to same pole        between them, and this sometimes
                                       ciently small com-                                                     causes such problems as white noises
Limit switch contact                   pared with R imped-                                                    and error pulses in both the electronic
                                       ance.                                                                  circuit and the reverberation equip-
                       r                                    Example of unsuitable power connec-               ment.
                             R  Can be used with both       tion (abnormal power connection)                  2) If the generation of bouncing and
                                AC and DC as appro-                                                           chattering becomes a problem, it is
                       c        priate.                     Risk of AC and DC being mixed.        Load        necessary to consider installing a CR
                                                               NO GOOD                              L         circuit or other absorption circuit given
Limit switch contact            r~R                                                                           the circuit design.
                                                                                   AC                         3) This is particularly necessary when
                                C: 0.1 F                                                                     high contact reliability is needed, and
Diode     R                                                                                                   is unsuitable for silver contact switch-
                                (1) Dedicated DC use.                                                         es. Switches with gold contacts pos-
                                (2) AC is impossible                                                          sess excellent performance.

                                                                       DC

Limit switch contact

ZNR       R                     Can be used with both                                       Load
Varistor                        AC and DC as appro-                                           L
                                priate.

                                                                                                                                 9
CAUTIONS FOR USE                           7) Do not apply unreasonable force to     12) Long term storage (including dur-
                                           the actuator, as this may result in dam-  ing transport) in high temperature or
CAUTIONS FOR USE                          age and impaired movement.                high humidity environments or where
                                           8) The switch, if dropped, may break      the atmosphere contains organic or
1) Do not attempt to physically alter      due to excessive vibration and impact.    sulfide gas, will cause sulfide or oxide
any part of the switch itself, such as     Therefore, please use extra caution       membrane to form on the contact sur-
the actuator, or switch attachment         when transporting and installing.         faces. This in turn will cause unstable
vent, as this may cause alterations to     9) Condensation inside the switch may     or failed contacting that may lead to
both characteristics and performance,      occur if there are rapid ambient tem-     functional malfunction. Please verify
and damage the insulation.                 perature changes when the switch is in    the atmosphere when storing and
2) Do not pour any lubricants such as      a high temperature and humidity.          transporting.
oil or grease onto the moving parts of     Since this occurs easily during marine    13) Packaging should be designed to
the actuator, as there is a possibility    transport, be extra cautious of what the  reduce as much as possible the poten-
that this will cause a malfunction due     environment will be when shipping.        tial influence of humidity, organic gas,
to seepage into the inside, and impair     Condensation is the phenomenon in         and sulfide gas, etc.
the motion. Silicon-based grease in        which water vapor condenses into          14) Please avoid sudden changes in
particular affects the contact points      switch-adhering water droplets when       temperature. This is a cause of switch
badly.                                     the temperature rapidly drops in a        deformation and encourages the seal
3) If the switches are not to be used for  high-temperature, high-humidity           structure to breathe, which may lead to
an extended period of time, their con-     atmosphere or when the switch is          seal failure and operational malfunc-
tact reliability may be reduced due to     quickly moved from a low temperature      tion.
oxidation of the contact points.           location to a place of high temperature   15) If installing a thermoplastic resin
Because accidents may result from the      and high humidity. It is the cause of     case, the use of a spring washer tight-
impaired conductivity, always imple-       insulation deterioration and of rust.     ened directly against the case will
ment a check beforehand.                   10) Be careful of freezing in tempera-    cause the case to collapse and
4) Prolonged continuous use of the         tures below 0C. Freezing is the phe-     become damaged. Therefore, please
switch hastens deterioration of the        nomenon in which moisture adhering        add a flat washer before tightening.
parts (especially the seal rubber) and     to the switch from condensation or        Also, be careful not to install if the
may cause a malfunction in the             when in unusually high-humidity envi-     case is being twisted.
release. For this reason, always imple-    ronments freezes onto the switch          16) For the purpose of improving quali-
ment a check beforehand.                   when the temperature drops below the      ty, materials and internal structure may
5) Usage in the vicinity of either the     freezing point. Please extra caution      be changed without notice.
switch operating position (O.P.) or the    because freezing can lock moving          17) When used outdoors (in places
release position (R.P.) results in unsta-  parts, cause operational delays, or       where there is exposure to direct sun-
ble contacts. If using the NC contact      interfere with conductivity when there    light or rain such as in multistory car
point, set the actuator to return to the   is ice between the contacts.              parks) or in ambient temperature envi-
free position (F.P.) Also, is using the    11) In low-temperature, low-humidity      ronments where ozone is generated,
NO contact point, hold the ratings val-    conditions, plastic becomes brittle and   the influence of these environments
ues down to 70 to 100% for the over-       the rubber and grease harden, which       may cause deterioration of the rubber
travel (O.T.)                              may lead to malfunction.                  material. Please consult us if you
6) If the actuator is forced beyond its                                              intend to use a switch in such environ-
total travel (T.T.), the internal mecha-                                             ments.
nism may be damaged. Always use
within the T.T.

PRECAUTIONS RELATING TO THE INSTALLATION ENVIRONMENT

Avoid using in silicon environments
such as organic silicon-based rubber,
solvents, sealants, oil, grease, or
wiring.

10
IMPROVEMENT EXAMPLES

   Poor design                                                       Improved design                                        Explanation

@                                              r                                                      Problem Dog adjustment is difficult.
                                                                                                      Solution Separate each one until the dog

                                                                                                                       can be adjusted.

@                                                                                                     Problem The dog axis is too long, and slips
                                                                                                                       out during operation.
   Dog axle                                    r
                                                                                                                      For this reason, the limit switch
                                                                                                                       operating position slips.

                                                                                                      Solution Firmly fix the dog plate to the base.

@  Detector                           Printer                                                         Problem The detector sinks, applying force
                                                                                                                       to the limit switch.
                                               r  Detector
                                                   Conveyer                                                          The limit switch O.T. cannot be set.
                                                                                      Rotation axle   Solution Relieve the pressure using an

                            Conveyer                                                                                   additional actuator, and the O.T.
                                                                                                                       can also be set.
@
                                                                                                      Problem The area around the actuator coil
                                               r                                                                       is easily damaged.

                                                                                      Rotation axle                   Friction generated during opera-
                                                                                                                       tion.

                                                                                                      Solution Relieve the friction by installing an
                                                                                                                       additional actuator.

                                                                                                                      Change the type of limit switch.

@                                                                                                     Problem Workers keep bumping the actua-
                                                                                                                       tor.
                         r
                                                                                                      Solution Fit a protective cover to the side of
                                  Limit                                                                                the limit switch.

@                                                 Protective cover                                    Problem    Because the cord vent for the limit
                                                                    High temperature                  Solution   switch faces upwards, water droplets
                         r                                                                                       and so forth can easily penetrate the
                                                                                                                 interior.

                                                                                                                The cord is constantly moving and
                                                                                                                 thus easily damaged.

                                                                                                                Fix the limit switch position on the
                                                                                                                 stationary board.

                                                                                                                Fit a protective cover, so that water
                                                                                                                 and oil cannot come into direct con-
                                                                                                                 tact with the limit switch.

@                                                                                                     Problem The cord is not fixed, and gets
                                                                                                                       pulled during work.
                         r
                                                                                                                      Dog adjustment is ineffective.
                                                                                                      Solution Change the limit switch position,

                                                                                                                       and fix the cord.

                                                                                                                      Attach an adjustment mechanism
                                                                                                                       to the dog.

@                                                                                                     Problem The limit switch is near a high-tem-
                                                                                                                       perature area.
                                               r
                                                                                                                      Dog adjustment is ineffective, and
   High temperature                                                                                                    the dog keeps bumping the lever.

                                                                                                      Solution Move the limit switch further away.
                                                                                                                      Make dog adjustment possible,
                                                                                                                       and change the shape of the unit.

                                                                                                                                                            11
IMPROVEMENT EXAMPLES

    Poor design              Improved design                                 Explanation

@   Detector  Dumper                                   Problem The detector is scratched.
                                                                      Limit attachment adjustments are
    Conveyer            r                                              difficult
                                                                      The actuator is damaged.
@                            Rotation axle                            Specimen transfer is impeded.
@
                        r                              Solution Fix the limit position to behind the
                                                                        dumper to solve the above prob-
              Conveyer                      Conveyer                    lems.

    Detector                 Detector                  Problem The transfer path of the detector is
                                                                        not fixed, and it keeps bumping the
                          r                                             actuator.

                      Dog                                              The operating position is unstable.
                                                                      The actuator is damaged.
@                                                      Solution Stabilize the operating position by

                         r                                              fitting an additional actuator.
                                                                      Make limit switch adjustment possible.

                                                       Problem Stroke adjustment ineffective.
                                                                      Release the limit switch position,
                                                                        and ensure that the dog does not
                                                                        bump the lever.

                                                       Solution Make dog adjustment possible.
                                                                      Change the limit switch position,
                                                                        and sure that the dog does not
                                                                        bump the lever.

                                                       Problem The cam shape is unsuitable
                                                                        (especially during release and
                                                                        strike release.)

                                                                      Direction of limit switch attachment
                                                                        is unsuitable.

                                                       Solution Render the cam shape smooth.
                                                                      Change the limit switch position.

12
Table of Recommended Substitute Products for Discontinued Products

         Products to be discontinued    Recommended substitute products   Page
AZ1 series Limit switches                      ML (AZ7) Limit switches    P.33
AZ2 series Limit switches                      ML (AZ7) Limit switches    P.33
Slitted type Limit switches (AZ6)              ML (AZ7) Limit switches    P.33
New slitted type Limit switches (AZ66)         ML (AZ7) Limit switches    P.33

Products to be discontinued              Recommended substitute products  Installation
                                        AZ7
AZ1   You cannot use this nut
      for panel installation.

                                                                          Please note that installation method and
                                                                          operation characteristics are different.

AZ2                                     AZ7

                                                                          Please note that installation method and
                                                                          operation characteristics are different.

AZ6                                     AZ7

                                                                          Please note that installation method and
                                                                          operation characteristics are different.

AZ66                                    AZ7

                                                                          Please note that installation method and
                                                                          operation characteristics are different.

                                                                                                                    77
FOREIGN STANDARDS OVERVIEW

1. International Standards                                                       3. Europe                   European Standards/Norme Europeennee
                                                                                                             (France)/Europaishe Norm (Germany)
IEC standard                                                                     EN standard                 Abbreviation for European Standards. A unified
                            International Electrotechnical Commission                                        standard enacted by CEN/CENELEC (European
                            By promoting international cooperation toward all    (1) Germany                 Standards Committee/European Electrical
                            problems and related issues regarding                                            Standards Committee). EU and EFTA member
                            standardization in the electrical and electronic        VDE                      nations employ the content of the EN standards into
                            technology fields, the IEC, a non-governmental                                   their own national standards and are obligated to
                            organization, was started in October, 1908, for the               TV Rheinland  abolish those national standards that do not agree
                            purpose of realizing mutual understanding on an                                  with the EN standards.
                            international level. To this end, the IEC standard
                            was enacted for the purpose of promoting                                         VDE (Verband Deutscher Elektrotechniker)
                            international standardization.                                                   The VDE laboratory was established mainly by the
                                                                                                             German Electric Technology Alliance, which was
2. North America                                                                                             formed in 1893. It carries out safety experiments
                                                                                                             and passes approval for electrical devices and
                        UL (Underwiters Laboratories Inc.)                                                   parts. Although VDE certification is not enforced
                                                                                                             under German law, punishment is severe should
    LISTING MARK        This is a non-profit testing organization formed in                                  electrical shock or fire occur; therefore, it is, in fact,
                        1894 by a coalition of U.S. fire insurance firms,                                    like an enforcement.

                        which tests and approves industrial products                                         TV (Technischer berwachungs-Verein)
                                                                                                             TV is a civilian, non-profit, independent
                        (finished products). When electrical products are                                    organization that has its roots in the German Boiler
                                                                                                             Surveillance Association, which was started in 1875
                        marketed in the U.S., UL approval is mandated in                                     for the purpose of preventing boiler accidents. A
                                                                                                             major characteristic of TV is that it exists as a
    Fig. 1              many states, by state law and city ordinances. In                                    combination of 14 independent organizations (TV
                        order to obtain UL approval, the principal parts                                     Rheinland, TV Bayern, etc.) throughout Germany.
                                                                                                             TV carries out inspection on a wide variety of
                        contained in industrial products must also be UL-                                    industrial devices and equipment, and has been
                                                                                                             entrusted to handle electrical products, as well, by
RECOGNITION MARK        approved parts.                                                                      the government. TV inspection and certification is
                        UL approval is divided into two general types. One                                   based mainly on the VDE standard.
                                                                                                             TV certification can be obtained from any of the 14
                        is called "listing" (Fig. 1), and applies to industrial                              TVs throughout Germany and has the same
                                                                                                             effectiveness as obtaining VDE certification.
                        products (finished products). Under this type of

    Fig. 2              approval, products must be approved
                        unconditionally. The other type is called

                        "recognition" (Fig. 2), and is a conditional approval

                        which applies to parts and materials.

         Certification  CSA (Canadian Standards Association)
                        This was established in 1919 as a non-profit, non-
        Fig. 3          governmental organization aimed at promoting
                        standards. It sets standards for industrial products,
Component Acceptance    parts, and materials, and has the authority to judge
                        electrical products to determine whether they
        Fig. 4          conform to those standards.The CSA is the ultimate
                        authority in the eyes of both the government and the
        Fig. 5          people in terms of credibility and respect. Almost all
                        states and provinces in Canada require CSA
                        approval by law, in order to sell electrical products.
                        As a result, electrical products exported from Japan
                        to Canada are not approved under Canadian laws
                        unless they have received CSA approval and
                        display the CSA mark. Approval is called
                        "certification", and products and parts which have
                        been approved are called "certified equipment", and
                        display the mark shown in Fig. 3. The mark shown
                        in Fig. 4 is called the "Component Acceptance"
                        mark, and indicates conditional approval which is
                        applicable to parts. The C-UL mark shown in Fig. 5
                        (finished products) and Fig. 6 (parts) indicates that
                        the product has been tested and approved in UL
                        laboratories, based on UL and CSA standards,
                        through mutual approval activities.

    Fig. 6

78
SAFETY STANDARDS RECOGNITION

Limit switches

                   Product name                            UL recognized                 CSA certified                                                      TV approval
                                                                                                                                                                 Approved ratings
                                               File No.    Approved ratings    File No.      Approved ratings                                     File No.                 
                                                                               LR55880                                                               
SL limit switches                              E122222     4A 250V AC                           4A 250V AC
                                                                                                5A 250V AC
            Dies-cast case standard load type               5A 250V AC                         Pilot duty B300                                               DC-12 1A 30V-
                                                           Pilot duty B300                                                                                  DC-12 0.1A 30V-
                                                                                                                                                  J9650514
            Die-cast case low level load type
HL limit    (includes connector type)          E122222      0.1A 30V DC        LR55880                                            0.1A 30V DC               AC-15 2A 250V~
switches                                                                                                                                                     DC-12 1A 30V-
            Plastic case standard load type                 5A 250V AC                                                            5A 250V AC
                                                           Pilot duty B300                                                       Pilot duty B300            DC-12 0.1A 30V-
                                                                                                                                                  J9650515

            Plastic case low level load type               0.1A 30V DC                                                           0.1A 30V DC

ML limit    Standard type                      E122222         10A 250V AC     E122222                                           10A 250V AC      J9551204  AC-15 2A 250V~
switches    Epoxy-sealed terminal type                                         (C-UL)
                                                                                                                                                                 
            With lamp                                                                                                                                              
                                               E122222          5A 250V AC                                                      5A 250V AC                          
QL limit switches                              E122222                                                                                            J9551203  AC-15 2A 250V~
                                               E122222          5A 250V AC     LR55880                                                                               
                                               E99838         Pilot duty B300
VL limit    Standard type                                                      E122222                                            5A 250V AC      J9551205  AC-15 2A 250V~
switches    With neon lamp                     E43149           6A 380V AC      (C-UL)                                           Pilot duty B300
                                                              Pilot duty A300
DL limit switches                              E122222     10A 1/2HP 125V AC   E122222                                            6A 380V AC
                                                            6A 1/2HP 250V AC    (C-UL)                                           Pilot duty A300

Vertical limit switches                                         5A 250V AC                                                                               

Compact     Standard type                                       2A 250V AC     E43149                                             5A 250V AC               
Magnelimit  Water-resistant type                                                (C-UL)
                                                                5A 250V AC                                                        2A 250V AC               
                                                              Pilot duty B300  E43149                                             5A 250V AC
Magnelimit                                                                      (C-UL)                                           Pilot duty B300           

                                                                               E122222
                                                                                (C-UL)

CE MARKINGS OVERVIEW

Limit switches conforming to EN/IEC standards                                                                                    The EN standards were established as
                                                                                                                                 universal EU standards in order to facili-
The limit switches shown below conform to both EN and IEC standards, and may dis-                                                tate EU directives. These standards
play the CE markings.                                                                                                            were merged with the international IEC
                                                                                                                                 standards and henceforth reflect the
Product classification   Product name   Suitable standard  Approving body            File No.                                    standards in all countries. Also, the CE
    Limit switches              HL        EN60947-5-1             TV        J9650514/J9650515                                   markings show that products conform to
                                ML        EN60947-5-1             TV                                                            EC directives, and guarantee the free
                                VL        EN60947-5-1             TV               J9551204                                     flow of products within the EC.
                                DL        EN60947-5-1             TV               J9551203
                                          EN60947-5-1                              J9551205                                     Appropriate EC directives
                           Magnelimit                                                                                            for control equipment
                                                                                                                                products

Note: Refer to the page for each individual product for detailed approval conditions and approved types. Moreover, the HL limit  The main EC directives that are to do
        switch alone does not display the CE mark as standard. If the CE mark is necessary, add (CE) to the end of the part No.  with machinery and electrical equipment
        when ordering.                                                                                                           are the machinery directive, the EMC
                                                                                                                                 directive, the low voltage directive, and
What are EN standards?                         CE markings and EC                                                                the telecom directive. Although these
                                               directives                                                                        directives have already been issued, the
An abbreviation of Norme Europeenne                                                                                              date of their enactment is different for
(in French), and called European               The world's largest single market, the                                            each one. The machinery directive was 1
Standards in English. Approval is by vote      European Community (EC) was born on                                               January 1995. The EMC directive was 1
among the CEN/CENELEC member                   1 January 1993 (changing its name to                                              January 1996, and the low voltage direc-
countries, and is a unified standards lim-     EU in November 1993. It is now always                                             tive was enacted from 1 January 1997.
ited to EU member countries, but the           expressed as EU, apart from EC direc-                                             The telecom directive was established by
contents conform to the international          tives.) EU member country products                                                the separate CTR (Common Technology
ISO/IEC standards.                             have always had their quality and safety                                          references.)
If the relevant EN standard does not           guaranteed according to the individual
exist, it is necessary to obtain approval      standards of each member country.                                                                                                    79
based on the relevant IEC standard or, if      However, the standards of each country
the relevant IEC standard does not exist,      being different prevented the free flow of
the relevant standard from each country,       goods within the EU. For this reason, in
such as VDE, BS, SEMKO, and so forth.          order to eliminate non-tariff barriers due
                                               to these standards, and to maximize the
                                               merits of EU unification, the EC direc-
                                               tives were issued concomitant to the
                                               birth of the EU.
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company