器件描述

Magnetic Sensor Development Tools AS5600 REF Module

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
ams
产品种类:
Product Category:
Magnetic Sensor Development Tools
RoHS:YES
产品:
Product:
Reference Designs
类型:
Type:
Magnetic Position Sensors
工具用于评估:
Tool Is For Evaluation Of:
AS5600
工作电源电压:
Operating Supply Voltage:
3.3 V
封装:
Packaging:
Bulk
系列:
Series:
AS5600
商标:
Brand:
ams
产品类型:
Product Type:
Magnetic Sensor Development Tools
工厂包装数量:
Factory Pack Quantity:
1
子类别:
Subcategory:
Development Tools
零件号别名:
Part # Aliases:
990600800

AS5600-SO_RD_ST器件文档内容

Operation Manual: AS5600-SO_RD_ST

AS5600

12-bit Programmable Contactless Potentiometer

www.ams.com  Revision  1.01 / 30.06.2014       page 1/11
AS5600-SO_RD_ST

Operation Manual

Table of Contents

1         General Description ............................................................................................................. 3

1.1       Kit Content ........................................................................................................................... 3

2         Getting Started ..................................................................................................................... 3

2.1       Adapter Board Pin-Out......................................................................................................... 3

2.2       Adapter Board Description ................................................................................................... 4

2.3       Mechanical Setup................................................................................................................. 5

2.4       Electrical Setup .................................................................................................................... 6

2.4.1     3-Wire Mode......................................................................................................................... 6

2.4.2     I2C Mode .............................................................................................................................. 6

3         AS5600 Configuration .......................................................................................................... 7

3.1       Programming the output range ............................................................................................ 7

3.2       Programming a configuration ............................................................................................... 7

3.2.1     Low Power Mode ................................................................................................................. 7

3.2.2     Hysteresis ............................................................................................................................ 7

3.2.3     Output selection ................................................................................................................... 7

3.2.4     Slow Filter ............................................................................................................................ 7

3.2.5     Fast Filter ............................................................................................................................. 7

3.2.6     Watchdog ............................................................................................................................. 8

4         Board Schematics, Layout and BOM................................................................................... 8

4.1       Schematics........................................................................................................................... 8

4.2       Layout and Board Dimensions ............................................................................................. 8

4.3       Bill of Materials ..................................................................................................................... 9

5         Evaluation tools .................................................................................................................. 10

6         Ordering Information .......................................................................................................... 10

Copyright ........................................................................................................................................... 11

Disclaimer .......................................................................................................................................... 11

Revision History

Revision     Date        Owner            Description

1.0          30.06.2014  rph              Initial Revision

1.1          31.07.2014  rph              Minor corrections

www.ams.com                     Revision  1.1 / 30.06.2014   page 2/11
AS5600-SO_RD_ST

Operation Manual

1         General Description

The reference design allows an easy and fast evaluation of the AS5600 rotary magnetic position

sensor in the lab. Additionally it is possible to replace an existing potentiometer with the AS5600-

SO_RD_ST. The module is fully assembled with and pcb including the AS5600 position sensor and

its necessary external components. All relevant signals are available on a 7-way connector and can

be easily wired to an existing application. Additionally there are tree-pin header to replace existing

potentiometers.

The AS5600 is a programmable Hall-based rotary magnetic position sensor with a high-resolution

12-bit analog or PWM output for contactless potentiometers. Based on planar Hall technology, this

device measures the orthogonal component of the flux density (Bz) from an external magnet while

rejecting stray magnetic fields.

The default range of the output is 0 to 360 degrees, but the full resolution of the device can be

applied to smaller range by programming a zero angle (start position) and maximum angle (stop

position).

The I²C interface is used for configuration and user programming of non-volatile parameters in the

AS5600 without requiring a dedicated programmer.

1.1  Kit Content

This kit contains following material listed in Table 1. Additional material can be found on our

webpage.

Table 1:

Kit Content

No.         Item                  Description        Info

1           AS5600-SO_RD_ST                          Reference Module including PCB

2           Quick Start Guide

2         Getting Started

The AS5600 reference design is a contactless potentiometer. It can be programmed in 3-Wire Mode

or over I2C.

2.1  Adapter Board Pin-Out

The pin-out of the reference module pcb is shown in

Table 2. For additional information on the AS5600 pins refer to the product datasheet.

www.ams.com                       Revision  1.1 / 30.06.2014                                          page 3/11
AS5600-SO_RD_ST

Operation Manual

Table 2:

Adapter Board Pin-Out (J1)

Pin       Symbol  Description                Info

1         VDD     Positive Power Supply

2         OUT     Output Pin                 Analog Output default, PWM possible, Is used

                                             for programming option B

3         DIR     Direction input            CCW default. Pulled to GND using R2. Remove

                                             R2 and insert at R1 for CCW direction.

4         PGO     Programming Mode           Pull to GND using R4 for Programming Option B

                                             (refer to the datasheet)

5         SDA     I2C Data

6         SCL     I2C Clock

7         GND     Ground

Table 3:

Adapter Board Pin-Out (J2)

Pin       Symbol  Description                Info

1         VDD     Positive Power Supply

2         OUT     Output Pin                 Analog Output default, PWM possible, Is used

                                             for programming option B

7         GND     Ground

2.2  Adapter Board Description

The AS5600 is connected over the 7-way header or by using the 3-Wire Mode. Connect the desired

pins of the AS5600 using the headers and resistors.

www.ams.com                        Revision  1.1 / 30.06.2014                              page 4/11
AS5600-SO_RD_ST

Operation Manual

Figure 1:

AS5600-SO_RD_ST   PCB     Description

                                Short J1

                                to operate

                                in 3.3V

                                mode

                                Use 0R for R4                         Use R1 or R2

                  3-Way Header         to enable                      to select the

     7-Way Header               PGO mode                              direction

2.3  Mechanical Setup

The contactless potentiometer reference design comes with the AS5600-SO_RD_ST               PCB

assembled. The PCB holds all necessary components to operate the AS5600 in a contactless

potentiometer application. The configuration of the reference module is shown in Figure 2.

Figure 2:

Mechanical Configuration

                                                 Potentiometer Shaft

                                                 Bearing

                                                 Sensor Magnet

                                                 AS5600

                                                 PCB

www.ams.com                            Revision  1.1 / 30.06.2014                                page 5/11
AS5600-SO_RD_ST

Operation Manual

The magnet is already aligned to get AGC values in the middle of the AGC range.

Note: If the magnetic field seen by the AS5600 would be below 8mT, the output would be switched

off and permanent angle programming would not be possible.

2.4    Electrical Setup

The reference module is many used in following configurations in 5V or in 3.3V mode.:

2.4.1  3-Wire Mode

In this mode, the power supply and the output pin of the reference module are connected. To

program a custom angular output range, short R4 using a 0R resistor to enable the programming

option B. Follow the step-by-step instructions in the AS5600 datasheet to program the device.

Figure 3:

Using the board in 3-Wire Mode

                         +

                   µC    -

       Analog or PWM IN

2.4.2  I2C Mode

Using the I2C Interface, all functions  of the AS5600 can be configured and permanently

programmed. Additionally the output     and a raw angle (unmodified value) can be read from    the

output registers.

Figure 4:

Using the reference module in I2C       Mode

                         +

                         -

                   µC

                       SDA

                       SCL

www.ams.com                             Revision  1.1 / 30.06.2014                             page 6/11
AS5600-SO_RD_ST

Operation Manual

3         AS5600 Configuration

All options to configure the AS5600 are shown below. The AS5600 operates with a default

configuration if no configuration was programmed.

3.1     Programming the output range

To adjust a custom angle to the full output range or to modify the Zero Position of the device, the

AS5600 must be programmed. Following options are availbale:

         Progamming start and stop position with I2C (Option A)

         Progamming start and stop position in 3-Wire Mode (Option B)

         Programming an angular excursion with I2C (Option C)

Follow the step-by-step instructions in the AS5600 datasheet for one of the above programming

options.

Note: To program only the zero position with Option B, Program an angular excursion of 360deg

using Option C first.

3.2     Programming a configuration

A configuration must be written using the I2C interface. The Burn_Setting command (Write 0x40

into register 0xFF) can be used to permanently program a configuration.

3.2.1     Low Power Mode

Three low power modes are available to reduce the power consumption down to 1,5mA max.

3.2.2     Hysteresis

A 1 to 3 LSB hysteresis of the 12-bit resolution can be enabled.

3.2.3     Output selection

Per default, the Analog Output is active if a magnet is present. Additionally the Output Pin can be

switched to PWM with the option to select a PWM frequency (115Hz,230Hz,460Hz,920Hz)

3.2.4     Slow Filter

The slow filter allows improving the output noise. The default setting for the Slow Filter is 16x and

can be reduced for faster response.

3.2.5     Fast Filter

The fast filter is active by selecting a Fast Filter Threshold. If the output value remains below the

threshold, the output noise is defined by the slow filter setting. When exceeding the threshold, the

output noise is defined from the fast filter for fast output response. The output noise is again defined

by the slow filter as soon as the output stays in the threshold again.

www.ams.com                          Revision  1.1 / 30.06.2014                                        page 7/11
AS5600-SO_RD_ST

Operation Manual

3.2.6  Watchdog

If the watchdog is active, the AS5600 automatically enters Low Power  Mode 3 after one  minute if

the output value stays within a threshold of 4 LSB.

4      Board Schematics, Layout and BOM

The schematic, layout and BOM of the adapterboard are shown below     for reference.

4.1    Schematics

The schematic of the board is shown below in Figure 5.

Figure 5:

Reference Module PCB Schematic

4.2    Layout and Board Dimensions

The PCB layout is shown below in Figure 6.

www.ams.com                     Revision    1.1 / 30.06.2014                            page       8/11
AS5600-SO_RD_ST

Operation Manual

Figure 6:

Reference Module PCB layout

4.3   Bill of Materials

The BOM of the pcb is below in Table   4.

Table 4:

Bill of Materials

Designator   Part                      Footprint                   Manufact  Comment

                                                                   urer

J1           Picoblade 7 Pin           Picoblade 7 Pin

J2           Header / not populated

R1           Resistor / not populated  R0603

R2           0R                        R0603                                 clockwise direction default

R3           Resistor / not populated  R0603

C1           C0603                     0603

C2           C0805                     0805

TVS1         SP0504BAHT                SP0504BAHT-SOT23

TVS2         SP0502BAHT                SP0502BAHT-SOT23

R4           Resistor / not populated  R0603

U1           AS5600                    SOIC-8                      amsAB     Smart Potentiometer IC

www.ams.com                            Revision  1.1 / 30.06.2014                     page                9/11
AS5600-SO_RD_ST

Operation Manual

5         Evaluation tools

To configure the AS5600, no dedicated programmer is needed. For fast setup time the USB I&P

Box can be used to configure the AS5600 over I2C. The USB I&P Box can be ordered from the ams

webpage.

Please find the ordering information below in Table 5.

Table 5:

Ordering Information for Evaluation Tools

Ordering Code         Description                       Image

USB I&P Box           To configure the AS5600

6         Ordering Information

Please find the ordering information below in Table 6.

Table 6:

Ordering Information

Ordering Code         Description                       Comments

AS5600-SO_RD_ST       AS5600 Reference Module           For rapid evaluation  and  prototyping

Get additional support material online at http://www.ams.com/AS5600.

www.ams.com                        Revision  1.1 / 30.06.2014                                page 10/11
AS5600-SO_RD_ST

Operation Manual

Copyright

Copyright ams AG, Tobelbader Strasse 30, 8141 Unterpremstätten, Austria-Europe. Trademarks

Registered. All rights reserved. The material herein may not be reproduced, adapted, merged,

translated, stored, or used without the prior written consent of the copyright owner.

Disclaimer

Devices  sold    by   ams   AG   are    covered   by    the  warranty     and  patent    indemnification  provisions

appearing    in  its  Term  of   Sale.  ams   AG   makes     no  warranty,     express,  statutory,  implied,  or  by

description  regarding      the  information  set  forth     herein.  ams      AG  reserves  the  right   to  change

specifications and prices at any time and without notice. Therefore, prior to designing this product

into a system, it is necessary to check with ams AG for current information. This product is intended

for use in commercial applications. Applications requiring extended temperature range, unusual

environmental requirements, or high reliability applications, such as military, medical life-support or

life-sustaining equipment are specifically not recommended without additional processing by ams

AG for each application. This Product is provided by ams “AS IS” and any express or implied

warranties, including, but not limited to the implied warranties of merchantability and fitness for a

particular purpose are disclaimed.

ams AG shall not be liable to recipient or any third party for any damages, including but not limited

to personal injury, property damage, loss of profits, loss of use, interruption of business or indirect,

special, incidental or consequential damages, of any kind, in connection with or arising out of the

furnishing, performance or use of the technical data herein. No obligation or liability to recipient or

any third party shall arise or flow out of ams AG rendering of technical or other services.

Contact Information

Headquarters

ams AG

Tobelbader Strasse 30

8141 Unterpremstaetten

Austria

T. +43 (0) 3136 500 0

For Sales Offices, Distributors and Representatives, please visit:

http://www.ams.com/contact

www.ams.com                                   Revision  1.1 / 30.06.2014                                      page 11/11
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory,  Delivery  &  Lifecycle  Information:

ams:

AS5600-SO_RD_ST

小广播

AS5600-SO_RD_ST器件购买:

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved