Amphenol ® ACA-B
Reverse Bayonet Coupling
Connectors
12-027-1
The Industrial Connector for Factory Automation, Robotics,
Process Control and Test & Measurement Equipment.
Amphenol
Table of Contents Page No.
Amphenol® ACA-B Reverse Bayonet Coupling Connectors
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Insert availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Insert alternate positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Contact arrangements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-24
ACA-B Connector Classes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
ACA 3100F-B wall mount receptacle for front panel mounting . . . . . . . . . . . . . . . . 26
ACA 3100E-B wall mount receptacle for front panel mounting . . . . . . . . . . . . . . . . 27
ACA 3100G-B wall mount receptacle for front panel mounting . . . . . . . . . . . . . . . . 28
ACA 3100R-B wall mount receptacle for front panel mounting . . . . . . . . . . . . . . . . 29
ACA 3101F-B cable connecting receptacle . . . . . . . . . . . . . . . . . . . . . 30
ACA 3101E-B cable connecting receptacle . . . . . . . . . . . . . . . . . . . . . 31
ACA 3101G-B cable connecting receptacle . . . . . . . . . . . . . . . . . . . . . 32
ACA 3101R-B cable connecting receptacle . . . . . . . . . . . . . . . . . . . . . 33
ACA 3102E-B box mount receptacle for front panel mounting . . . . . . . . . . . . . . . . 34
ACA 3103F-B wall mount receptacle for rear panel mounting . . . . . . . . . . . . . . . . 35
ACA 3103E-B wall mount receptacle for rear panel mounting . . . . . . . . . . . . . . . . 36
ACA 3103G-B wall mount receptacle for rear panel mounting . . . . . . . . . . . . . . . . 37
ACA 3103R-B wall mount receptacle for rear panel mounting . . . . . . . . . . . . . . . . 38
ACA 3106F-B straight plug . . . . . . . . . . . . . . . . . . . . . . . . . 39
ACA 3106E-B straight plug . . . . . . . . . . . . . . . . . . . . . . . . . 40
ACA 3106G-B straight plug . . . . . . . . . . . . . . . . . . . . . . . . . 41
ACA 3106R-B straight plug . . . . . . . . . . . . . . . . . . . . . . . . . 42
ACA 3107A-B jam nut receptacle. . . . . . . . . . . . . . . . . . . . . . . . 43
ACA 3108F-B 90 degree angle plug . . . . . . . . . . . . . . . . . . . . . . . 44
ACA 3108E-B 90 degree angle plug . . . . . . . . . . . . . . . . . . . . . . . 45
Connector Accessories - sealing gaskets . . . . . . . . . . . . . . . . . . . . . . 46
Connector Accessories - receptacle protection caps . . . . . . . . . . . . . . . . . . . 47
Accessories - plug protection caps . . . . . . . . . . . . . . . . . . . . . . . . 48
Accessories - rear mounting data - receptacles, sealing plugs, sealing ranges. . . . . . . . . . . . . 49
Accessories - crimp and solder contact information. . . . . . . . . . . . . . . . . . . 50-52
ACA-B Connectors How to Order, connector intermateability. . . . . . . . . . . . . . . . . . . . . 53
Sales office listing
For further information on your individual application requirements, contact:
Amphenol Corporation
Amphenol Industrial Operations
40-60 Delaware Avenue
Sidney, New York 13838-1395
Phone: 607-563-5011 Fax: 607-563-5351
View and download or print Amphenol catalogs on-line at: www.amphenol-industrial.com
Amphenol Aerospace is a Certified ISO 9001 Manufacturer
Amphenol ® ACA-B Connectors
with reverse bayonet coupling
Features of the Amphenol ® ACA-B Reverse
Bayonet Coupling Connectors with MIL-DTL-
5015 insert patterns:
• Quick positive coupling
• Audible and tactile indication of full coupling
• Waterproof - IP67 rated The ACA-B is designed for commercial and Industrial
• No lockwiring required environments requiring a rugged bayonet style connec-
• High shock and vibration capabilites tor for heavy duty power and signal applications.
• Inserts available in Neoprene A comprehensive selection of insert arrangements and acces-
• Available in both crimp and solder terminations sory hardware configurations are featured to accommodate
• Contacts available in gold and silver plating heavy-duty, commercial wire and cable.
• Numerous finishes available ACA-B is manufactured in accordance with MIL-DTL-5015 and
• Zinc alloy plating (cadmium free) available VG95234. The insulators are made of high quality polychloro-
• Rugged construction prene material and can withstand temperatures of –55 to +125
• Intermateable with existing VG95234 connectors degrees C. The rugged shell is made from aluminum alloy and
• 500 couplings minimum plated with a variety of finishes to meet any application. Con-
• Up to 50% more ampacity with the use of RADSOK® tacts are machined from copper alloy or brass and can be
socket contacts. Consult Amphenol Industrial Opera- plated with gold or silver.
tions for more information or see Amphenol® Amphe- Common applications include automation, machine tool, robot-
Power Connectors with RADSOK® Technology, SL-
391 (online at www.amphenol-industrial.com). ics, instrumentation, process control, material handling, and
• Operating temperature range: -55°c to 125°c test and measurement.
RoHS Compliant Product Amphenol
Available – Consult RoHS
Amphenol Industrial Operations.
EU / 2002 / 95 / EC
1
ACA-B
insert availability
Insert Total Contact Size Insert Total Contact Size
Arrange- Service Con- Coax Arrange- Service Con- Coax
ment Rating tacts 0 4 8 12 16 0 4 8 12 ment Rating tacts 0 4 8 12 16 0 4 8 12
10SL-3 A 3 3 20-2 D 1 1
10SL-4† A 2 2 20-3 D 3 3
14S-2 Inst. 4 4 20-4 D 4 4
14S-4 D 1 1 20-6 D 3 3
14S-5 Inst. 5 5 20-7 D/A 8 8
14S-6 Inst. 6 6 20-8 Inst. 6 2 4
14S-7 A 3 3 20-9 D/A 8 1 7
14S-9 A 2 2 20-11 Inst. 13 13
14S-10 Inst. 4 4 20-12 A 2 1 1
14S-12 A 3 3 20-14 A 5 2 3
14S-A7 A 7 7 20-15 A 7 7
16S-1 A 7 7 20-16 A 9 2 7
16S-3 B 1 1 20-17 A 6 5 1
16S-4 D 2 2 20-18 A 9 3 6
16S-5 A 3 3 20-19 A 3 3
16S-6 A 3 3 20-20 A 4 1 3
16S-8 A 5 5 20-21 A 9 1 8
16-2 E 1 1 20-22 A 6 3 3
16-7 A 3 1 2 20-23 A 2 2
16-9 A 4 2 2 20-24 A 4 2 2
16-10 A 3 3 20-25 Inst. 13 13
16-11 A 2 2 20-26 A 19 19
16-12 A 1 1 20-27 A 14 14
16-13 A 2 2 20-29 A 17 17
16-59 A 4 4 20-30 Inst. 13 13
18-1 A/Inst. 10 10 20-33 A 11 11
18-3 D 2 2 20-51 A 3 3
18-4 D 4 4 20-57 A 7 7*
18-5 D 3 2 1 20-58 A 10 5 5
18-6 D 1 1 20-59 A 3 3*
18-7 B 1 1 20-66 A 6 5* 1
18-8 A 8 1 7 20-79 A/D 8 1 7
18-9 Inst. 7 2 5 22-1 D 2 2
18-10 A 4 4 22-2 D 3 3
18-11 A 5 5 22-4 A 4 2 2
18-12 A 6 6 22-5 D 6 2 4
18-13 A 4 1 3 22-6 D 3 2 1
18-14 A 2 1 1 22-7 E 1 1
18-15 A 4 4 22-8 E 2 2
18-17 Inst. 7 2 5 22-9 E 3 3
18-19 A 10 10 22-10 E 4 4
18-20 A 5 5 22-11 B 2 2
18-22 D 3 3 22-12 D 5 2 3
18-24 A/Inst. 10 10 22-13 D/A 5 4 1
18-29 A 5 5 22-14 A 19 19
18-30 A 5 5 22-15 E/A 6 5 1
18-31 A 5 5 †10SL-4 arrangement available only with pin contacts in receptacle and socket
*Crimp contacts accommodate wire the same size as the contact as well as wire of contacts in plug
the next smaller, even size. Arrangements identified with an asterisk (*) are excep- **Coaxial cable data can be found on insert arrangement drawings, pages 6-24.
tions. See insert arrangement drawings on pages 6-24 for application wire size. For further information on coaxial contacts and cable see catalog 12-130.
2
ACA-B
insert availability, cont.
Insert Total Contact Size Contact Size
Coax** Insert Total Coax**
Arrange Service Con- Arrange Service Con-
ment Rating tacts 0 4 8 12 16 0 4 8 12 ment Rating tacts 0 4 8 12 16 0 4 8 12
22-16 A 9 3 6 24-84 A 19 1 18
22-17 D/A 9 1 8 24-96 Inst. 28 28
22-18 D/A 8 8 24-AJ A 25 25
22-19 A 14 14 28-1 D/A 9 3 6
22-20 A 9 9 28-2 D 14 2 12
22-21 A 3 1 2 28-3 E 3 3
22-22 A 4 4 28-4 E/D 9 2 7
22-23 D/A 8 8 28-5 D 5 2 1 2
22-24 D/A 6 2 4 28-6 D 3 3
22-27 D/A 9 1 8 28-7 D 2 2
22-28 A 7 7 28-8 E/D/A 12 2 10
22-33 D/A 7 7 28-9 D 12 6 6
22-34 D 5 3 2 28-10 D/A 7 2 2 3
22-63 A 12 4 8 28-11 A 22 4 18
22-65 D/A 8 8* 28-12 A 26 26
22-70 A 13 8 5 28-13 A 26 26
22-80 A 3 3* 28-15 A 35 35
24-2 D 7 7 28-16 A 20 20
24-3 D 7 2 5 28-17 B/D/A 15 15
24-5 A 16 16 28-18 C/D/A/ 12 12
24-6 D/A 8 8 Inst.
24-7 A 16 2 14 28-19 B/D/A 10 4 6
24-9 A 2 2 28-20 A 14 10 4
24-10 A 7 7 28-21 A 37 37
24-11 A 9 3 6 28-22 D 6 3 3
24-12 A 5 2 3 28-51 A 12 12
24-16 D/A 7 1 3 3 28-59 A 17 7 10
24-17 D 5 2 3 28-66 A 16 2 14
24-19 A 12 12 28-72 Coax 3 3
24-20 D 11 2 9 28-74 A 16 7* 9
24-21 D 10 1 9 28-75 A 16 7* 9
24-22 D 4 4 28-79 A 16 7 9
24-27 E 7 7 28-82 D 6 2 4
24-28 Inst. 24 24 28-84 A 9 9
24-51 A 5 5 28-AY A 9 4 5
24-52 Hi Volt. 1 1 32-1 E/D 5 2 3
24-53 A 5 5 32-2 E 5 3 2
24-58 A 13 3 3 7 32-3 D 9 1 2 2 4
24-59 A 14 7 7 32-4 A/D 14 2 12
24-60 A 7 7* 32-5 D 2 2
24-65 A 15 11 4 32-6 A 23 2 3 2 16
24-66 D 7 7 32-7 Inst./A 35 7 28
24-67 Inst. 19 19 32-8 A 30 6 24
24-71 A 7 7* 32-9 D 14 2 12
24-75 A 7 7* 32-10 E/B/D/A 7 2 2 3
24-79 A 5 5 32-12 A/D 15 5 10
24-80 Inst. 23 23 32-13 D 23 5 18
*Crimp contacts accommodate wire the same size as the contact as well as wire of **Coaxial cable data can be found on insert arrangement drawings, pages 6-24.
the next smaller, even size. Arrangements identified with an asterisk (*) are excep- For further information on coaxial contacts and cable see catalog 12-130.
tions. See insert arrangement drawings on pages 6-24 for application wire size.
3
ACA-B
insert availability, cont.
Insert Total Contact Size Insert Total Contact Size
Arrange- Service Con- Coax** Arrange- Service Con- Coax**
ment Rating tacts 0 4 8 12 16 0 4 8 12 ment Rating tacts 0 4 8 12 16 0 4 8 12
32-15 D 8 2 6 36-11 A 48 48
32-16 A 23 2 3 2 16 36-12 A 48 48
32-17 D 4 4 36-13 E/A 17 2 15
32-22 A 54 54 36-14 D 16 5 5 6
32-25 A 25 25 36-15 D/A 35 35
32-31 A 31 31 36-16 A 47 7 40
32-48 Inst. 48 48 36-17 A 47 7 40
32-52 D 8 2 6 36-18 A 31 1 2 14 14
32-53 E/Inst. 42 5 37 36-20 A 34 2 2 30
32-56 A 30 6* 24 36-22 D 22 22
32-57 Coax 8 6 2 36-51 D 4 2 2
32-58 Coax 4 4 36-52 A 52 52
32-59 A 42 40 2 36-54 A 39 8 31
32-60 A 23 15 8 36-55 A 39 8* 31
32-62 Coax 23 2 1 2 16 2 36-59 A 53 3* 50
32-64 Inst. 54 54 36-60 A 47 7* 40
32-68 A 16 12 4 36-64 Coax 4 4
32-73 A 46 46 36-65 Coax 4 4
32-75 Coax 9 2 7 36-71 A 53 3 50
32-76 A 19 19 36-73 Coax 7 7
32-79 D 5 4 1 36-74 A 44 43 1
32-82 A 16 4 12 36-75 A 48 48*
32-AF A 55 55 36-76 A 47 47
32-AM A 1 1 size 4/0 36-77 D 7 7
36-1 D 22 4 18 36-78 A 14 12 2
36-3 D 6 3 3 36-79 A 20 20
36-4 D/A 3 3 36-80 A 20 20*
36-5 A 4 4 36-83 Coax 7 7
36-6 A 6 2 4 36-85 A/D 35 35*
36-7 A 47 7 40 36-97 C 1 1 size 4/0
36-8 A 47 1 46 36-99 D 12 3 3 3 3
36-9 A 31 1 2 14 14 36-AF A 48 48
36-10 A 48 48 **Coaxial cable data can be found on insert arrangement drawings, pages 6-24.
*Crimp contacts accommodate wire the same size as the contact as well as For further information on coaxial contacts and cable see catalog 12-130.
wire of the next smaller, even size. Arrangements identified with an asterisk (*)
are exceptions. See insert arrangement drawings on pages 6-24 for applica-
tion wire size.
4
ACA-B
insert alternate positioning
To avoid cross-plugging problems in applications requir- The following insert arrangements have the same alter-
ing the use of more than one connector of the same size nate insert rotations for W, X, Y and Z, which are:
and arrangement, alternate rotations are available as
indicated in the accompanying charts. Degrees
As shown in the diagram below, the front face of the pin W X Y Z
insert is rotated within the shell in a clockwise direction 80 110 250 280
from the normal shell key. The socket insert would be
rotated counter-clockwise the same number of degrees 16-7 20-16 22-18 24-4 24-28 28-16 32-10
in respect to the normal shell key. 18-5 20-20 22-19 24-5 24-AJ 28-17 32-12
18-9 20-22 22-21 24-6 28-1 28-19 32-13
18-13 22-3 22-24 24-7 28-4 28-20 32-22
18-14 22-6 22-25 24-12 28-8 28-21 32-AF
A B
A B 20-7 22-12 22-29 24-14 28-9 32-1 36-1
B A
B A 20-8 22-14 22-33 24-16 28-10 32-3 36-7
20-9 22-15 22-34 24-17 28-11 32-4 36-8
Position W Position X Position Y Position Z 20-12 22-16 24-1 24-20 28-14 32-6 36-13
20-14 22-17 24-3 24-21 28-15 32-9
View looking into front face of pin insert or rear of socket insert.
Insert Degrees Insert Degrees Insert Degrees
Arrangement W X Y Z Arrangement W X Y Z Arrangement W X Y Z
10SL-4 63 – – – 20-21 35 110 250 325 28-12 90 180 270 –
14S-2 – 120 240 – 20-23 35 110 250 325 28-18 70 145 215 290
14S-5 – 110 – – 20-24 35 110 250 325 28-22 70 145 215 290
14S-7 90 180 270 – 20-27 35 110 250 325 28-AY 45 110 250 –
14S-9 70 145 215 290 20-29 80 – – 280 32-2 70 145 215 290
16-9 35 110 250 325 20-33 – – – 280 32-5 35 110 250 325
16-10 90 180 270 – 22-1 35 110 250 325 32-7 80 125 235 280
16-11 35 110 250 325 22-2 70 145 215 290 32-8 80 125 235 280
16-13 35 110 250 325 22-4 35 110 250 325 32-15 35 110 250 280
16S-1 80 – – 280 22-5 35 110 250 325 32-17 45 110 250 –
16S-4 35 110 250 325 22-8 35 110 250 325 32-25 60 120 – –
16S-5 70 145 215 290 22-9 70 145 215 290 32-64* 80 100 110 250
16S-6 90 180 270 – 22-10 35 110 250 325 32-68 30 – – –
16S-8 – 170 265 – 22-11 35 110 250 325 32-82 30 – – –
18-1 70 145 215 290 22-13 35 110 250 325 36-3 70 145 215 290
18-3 35 110 250 325 22-20 35 110 250 325 36-4 70 145 215 290
18-4 35 110 250 325 22-22 – 110 250 – 36-5 – 120 240 –
18-8 70 – – 290 22-23 35 – 250 – 36-6 35 110 250 325
18-10 – 120 240 – 22-27 80 – 250 280 36-9 80 125 235 280
18-11 – 170 265 – 22-28 80 – – 280 36-10 80 125 235 280
18-12 80 – – 280 24-2 80 – – 280 36-14 90 180 270 –
18-15 – 120 240 – 24-9 35 110 250 325 36-15 60 125 245 305
18-20 90 180 270 – 24-10 80 – – 280 36-AF 65 – – –
18-22 70 145 215 290 24-11 35 110 250 325 *Additional rotations available; consult Amphenol for
18-29 90 180 270 – 24-22 45 110 250 – information.
20-3 70 145 215 290 24-27 80 – – 280
20-4 45 110 250 – 24-96 65 – – –
20-5 35 110 250 325 28-2 35 110 250 325
20-6 70 145 215 290 28-3 70 145 215 290
20-15 80 – – 280 28-5 35 110 250 325
20-17 90 180 270 – 28-6 70 145 215 290
20-18 35 110 250 325 28-7 35 110 250 325
20-19 90 180 270 –
5
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
E A
B A D A
A C C B B
B D
Front of Front of C
Socket Insert Socket Insert
Insert Arrangement 10SL-3 10SL-4 14S-2 14S-4 14S-5
Service Rating A A Inst. D Inst.
Number of Contacts 3 2 4 1 5
Contact Size 16 16 16 16 16
F A 100˚ 100˚ A
B A B
D A F G
E B C A C A C
C B E
D C B B D
100° Rotation 100° Rotation
of 14S-2 of 14S-7
Insert Arrangement 14S-6 14S-7 14S-9 14S-10 14S-12 14S-A7
Service Rating Inst. A A Inst. A A
Number of Contacts 6 3 2 4 3 7
Contact Size 16 16 16 16 16 16
F A E
A C D A
E A
G B
B A
D C C B B B
C
Insert Arrangement 16S-1 16S-3 16S-4 16S-5 16S-6 16S-8
Service Rating A B D A A A
Number of Contacts 7 1 2 3 3 5
Contact Size 16 16 16 16 16 16
A B A
C D B
C
Insert Arrangement 16-2 16-7 16-9
Service Rating E A A
Number of Contacts 1 1 2 2 2
Contact Size 12 8 16 12 16
CONTACT LEGEND 16 12 8 4 0
6
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
C A A
B A A B
B C D
B
Insert Arrangement 16-10 16-11 16-12 16-13 16-59
Service Rating A A A A A
Number of Contacts 3 2 1 2* 4
Contact Size 12 12 4 12 12
H A
G D A A
I B
F J B A C B
C C B
E D
Insert Arrangement 18-1 18-3 18-4 18-5 18-6 18-7
Service Rating B, C, F, G = A; Bal. = Inst. D D D D B
Number of Contacts 10 2 4 2 1 1 1
Contact Size 16 12 16 12 16 4 8
G F C E F D
F A D A E A
E B D A
E H B G C A
C D A C B C B D B
D C B
Insert Arrangement 18-8 18-9 18-10 18-11 18-12 18-13
Service Rating A Inst. A A A A
Number of Contacts 1 7 2 5 4 5 6 1 3
Contact Size 12 16 12 16 12 12 16 8 12
A 100˚ A
F C B C A B
E B D E F G
B D B G
A C H J E C
D A K D
100° Rotation
of 18-9
Insert Arrangement 18-14 18-15 18-17 18-19 18-20
Service Rating A A Inst. A A
Number of Contacts 1 1 4** 2 5 10 5
Contact Size 4 16 12 12 16 16 16
CONTACT LEGEND 16 12 8 4 0
* A = Iron; B = Constantan
**A, C = Iron; B, D = Constantan 7
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
H A 110˚ A B
G E A A B
G B
I
A B 250˚ F J C E C E C
C D B
E D D 260˚ D
250° Rotation 110° Rotation 260° Rotation
of 18-1 of 18-20 of 18-20
Insert Arrangement 18-22 18-24 18-29 18-30 18-31 20-2
Service Rating D B, C, F, G = A; Bal. = Inst. A A A D
Number of Contacts 3 10 5 5 5 1
Contact Size 16 16 16 16 16 0
A C A
A D A A
G B E F B G B
H H
F C
F C
C B C B D A E D
C B E D
Insert Arrangement 20-3 20-4 20-6 20-7 20-8 20-9
Service Rating D D D A, B, H, G = D; C, D, E, F = A Inst. H = D; Bal. = A
Number of Contacts 3 4 3 8 2 4 1 7
Contact Size 12 12 16 16 8 16 12 16
L E F G E
A E F A
B C D A
M F A E G B D I H
D F
G E H B
N K B C B
A D C C A
D J C B
Insert Arrangement 20-11 20-12 20-14 20-15 20-16 20-17
Service Rating Inst. A A A A A
Number of Contacts 13 1 1 2 3 7 2 7 5 1
Contact Size 16 4 16 8 12 12 12 16 12 16
CONTACT LEGEND 16 12 8 4 0
8
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
H A F
G A A D A H B A
F I B I E A
C G C
D B
E C C B F D
D E C B
B
Insert Arrangement 20-18 20-19 20-20 20-21 20-22 20-23
Service Rating A A A A A A
Number of Contacts 3 6 3 1 3 1 8 3 3 2
Contact Size 12 16 8 4 12 12 16 8 16 8
100˚ M A B
A L L A J A M L
B C U N I B N C B C
M F K V B K L M F
J C H T P D
E T P N L E
N G H K C K S R N G H K
D B H S R D G M D E
C D A J G E J D A J
F E F 250˚
F H G
100° Rotation 250° Rotation
of 20-11 of 20-11
Insert Arrangement 20-24 20-25 20-26 20-27 20-29 20-30
Service Rating A Inst. A A A Inst.
Number of Contacts 2 2 13 19 14 17 13
Contact Size 8 16 16 16 16 16 16
A J E
K B C A F A H K C A
M D E A D A
J C E G B F
L L
H D C C B C B
D
F E B F B
Insert Arrangement 20-33 20-51 20-57 20-58 20-59 20-66
Service Rating A A A A A A
Number of Contacts 11 3* 7* 5 5 3* 1 5
Contact Size 16 8 12 for #14 or 16 wire 12 16 8 for #10 or 12 wire 16 12 for #10 wire
* Solderless CONTACT LEGEND 16 12 8 4 0
9
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
A A
G B A F A
H E B
F C
B A D B
E D C B
C D C
Insert Arrangement 20-79 22-1 22-2 22-4 22-5
Service Rating H=D; Bal. =A D D A D
Number of Contacts 7* 1* 2 3 2 2 2 4
Contact Size 16 12 for #16 wire 8 8 8 12 12 16
A A D A
B B A
C B C B
C
Insert Arrangement 22-6 22-7 22-8 22-9 22-10
Service Rating D E E E E
Number of Contacts 2 1 1 2 3 4
Contact Size 8 16 0 12 12 16
A L M A
A
E B D A K U N B F B
B A E J T V P C
C B H S R D
E C
D C G E D
F
Insert Arrangement 22-11 22-12 22-13 22-14 22-15
Service Rating B D E = D; A, B, C, D = A A D= E; A, B, C, E, F = A
Number of Contacts 2 2 3 4 1 19 5 1
Contact Size 16 8 16 12 16 16 12 16
* Solderless CONTACT LEGEND 16 12 8 4 0
10
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
A G A A
A K B G H A
F G H B H B L
G C F H B J P M C
F J B
J J
E C F E H N D
D C
G E E D C
D E D F
Insert Arrangement 22-16 22-17 22-18 22-19 22-20
Service Rating A A = D; Bal. = A A, B, F, G, H = D; C, D, E = A A A
Number of Contacts 3 6 1 8 8 14 9
Contact Size 12 16 12 16 16 16 16
G A H A
A F A F B B
C D A H J
B G
E C C
E
B C B D F D
C
D E
Insert Arrangement 22-21 22-22 22-23 22-24 22-27
Service Rating A A H = D; Bal. =A C, D, E = D; A, B, F = A J= D; Bal. = A
Number of Contacts 1 2 4 8 2 4 1 8
Contact Size 0 16 8 12 12 16 8 16
D A A B C G
F A F A
C B L H
E G B A D B
C E B N M E
E D K E C
D C G F J F D
H
Insert Arrangement 22-28 22-33 22-34 22-63 22-65
Service Rating A A, B, C, D = D; E. F. G = A D A H = D; Bal. = A
Number of Contacts 7 7 3 2 4 8 8*
Contact Size 12 16 12 16 12 16 12 for #14 or 16 wire
* Solderless CONTACT LEGEND 16 12 8 4 0
11
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
J A A F A F A A B
K C
H B G G D E
L E B E B F G H
P M J K
F C L M N
N C B
E D D C D C P R
S
Insert Arrangement 22-70 22-80 24-2 24-3 24-5
Service Rating A A D D A
Number of Contacts 8 5 3* 7 2 5 16
Contact Size 12 16 8 for #10 or 12 wire 12 12 16 16
A A B C
G A L B F A
F H B K M C B A G
P N E B D E F
J D
E C I O E G I
D C
D H F H
G
Insert Arrangement 24-6 24-7 24-9 24-10 24-11
Service Rating A, G, H = D; Bal. = A A A A A
Number of Contacts 8 2 14 2 7 3 6
Contact Size 12 12 16 4 8 8 12
A D N A J A B
A F B C E M B
G H C
E L C K L
D B E C G D
K D
C B A
D J H F E F E
Insert Arrangement 24-12 24-16 24-17 24-19 24-20
Service Rating A A, B, F, G = D; C, D, E= A D A D
Number of Contacts 2 3 1 3 3 2 3 12 2 9
Contact Size 4 12 8 12 16 12 16 16 12 16
* Solderless CONTACT LEGEND 16 12 8 4 0
12
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
A
H B D A A A B C D
F B E F G H J E A
G J K C K L M N P Q
D B
G R S T U V
F D E C
C B D
E W X Y Z C
Insert Arrangement 24-21 24-22 24-27 24-28 24-51
Service Rating D D E Inst. A
Number of Contacts 1 9 4 7 24 5*
Contact Size 8 16 8 16 16 B, E for AN #10 or 12 wire
A, C, D for AN #8 wire
P H J P J
N K F A
E A N K R G
F D M H A L E B
D B M L
F B
E
C A E C D C
C B D
Insert Arrangement 24-52 24-53 24-58 24-59 24-60
Service Rating Hi-Volt A A A A
Number of Contacts 1 5* 3 3 7 7 7 7*
Contact Size 12 8 8 12 16 12 16 8 for #10 or 12 wire
L A E 90˚
K F A F D F A F A
M R
J B E G B S P E G B E G B
S N G V C
H T N B
H R P C J U A
D C D C D C
F D K M
E L
Insert Arrangement 24-65 24-66 24-67 24-71 24-75
Service Rating A D Inst. A A
Number of Contacts 11 4 7 19 2* 5* 5 2
Contact Size 12 16 12 12 8 8 for #10 or 12 wire 8 8 for #16 wire
* Solderless CONTACT LEGEND 16 12 8 4 0
13
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
A B C D E 90˚ 15 16 1
F D 14 24 2 A B C D
E F G H J R 17 3 G
E A S P 13 23 28 E F H J
K L M N P Q G V C 4 K M Q
D B H B 12 22 27 25 18 L N P
S T U T N T
R V J U A 11 26 5 R S U V
21 19
10 20 6 W X Y Z
C W X Z K M 9 7 a
L 8
Insert Arrangement 24-79 24-80 24-84 24-96 24-AJ
Service Rating A Inst. A Inst. A
Number of Contacts 5 23 1 18 28 25
Contact Size 8 16 12 12 (Coax) RG-188/U 16 16
or RG-174/U
H A B K A A
S A B
J L B
G J C P M P C D
H C
G E F
G N D C B
F E D F E
Insert Arrangement 28-1 28-2 28-3 28-4
Service Rating A, J, E = D; Bal. = A D E G, P, S = E; Bal. = D
Number of Contacts 3 6 2 12 3 2 7
Contact Size 8 12 12 16 8 12 16
H
A A
A G
E B B A M J
B
F K
L
C B E
D C C
D
Insert Arrangement 28-5 28-6 28-7 28-8
Service Rating D D D L, M = E; B = D; Bal. = A
Number of Contacts 2 1 2 3 2 2 10
Contact Size 4 12 16 4 4 12 16
CONTACT LEGEND 16 12 8 4 0
14
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
J N J E R A
H A F A P S
F a T B
K U P K A
G B G N Z b U C
E B V R G B M
L D
F M L C W S H C Y d V
L E
X D W
M K X F
T I J G
E D D C H
Insert Arrangement 28-9 28-10 28-11 28-12
Service Rating D G= D; Bal. = A A A
Number of Contacts 6 6 2 2 3 4 18 26
Contact Size 12 16 4 8 12 12 16 16
100˚ P R A A B K A C D
S C D E F G B B
a T B H J K L M N H J K
C J T L M C E
N Z b U P R S T U V W A G L
M F
D X Y Z a b c S V U N
Y d V D
L E e g H R Q P R M
W d h
K X F f P
j k
J G l m G F E N
H
100° Rotation
of 32-6
Insert Arrangement 28-13 28-15 28-16 28-17
Service Rating A A A R= B; M, N, P = D; A to L = A
Number of Contacts 26 35 20 15
Contact Size 16 16 16 16
A A B J A
L B B
L C
K N K
C K M E H P
M C
J D
E G M L
H J G D
G F H F
E
Insert Arrangement 28-18 28-19 28-20
Service Rating M = C; G, H, J, K,L = D; A, B= A; Bal. = Inst. H, M = B; A, B, = D; Bal. = A A
Number of Contacts 12 4 6 10 4
Contact Size 16 12 16 12 16
* Solderless CONTACT LEGEND 16 12 8 4 0
15
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
B C J A L M N
A D C A
E F G H J F H B P R S T U
K L M N P R K
S T U V W X Z N L A B C D
a b c d e f B
M
g h j k m F C E H
E D F
n p r s E D J K
Insert Arrangement 28-21 28-22 28-51 28-59
Service Rating A D A A
Number of Contacts 37 3 3 12 7 10
Contact Size 16 4 16 12 12 16
P R C N A N A
A M P B M P B
N S D T R T R
L C L C
E K D K D
M
B A
L T F J S E J S E
C B H F H F
K H
J
Insert Arrangement 28-66 28-72 28-74 28-75
Service Rating A – A A
Number of Contacts 2 14 3 9* 4* 3* 9* 7*
Contact Size 8 12 4 (Coax) RG-59A/U 16 8 8 for #10 wire 16 8 for #10 wire
or RG-62A/U (S, T, R)
N A B C
M P B 1 3 2 H A A
T R
L C
K D G I B D E F
F C
S 4 5 G H
J E J
H F E D
6
Insert Arrangement 28-79 28-82 28-84 28-AY
Service Rating A D A A
Number of Contacts 7 9 2 4 9 4 5
Contact Size 8 16 8 12 8 4 16
* Solderless CONTACT LEGEND 16 12 8 4 0
16
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
A B F
A A C A K
E D E F G L
E B B
C O
B H
G J D M
D C D H
C E N
J
Insert Arrangement 32-1 32-2 32-3 32-4
Service Rating A = E; B, C, D, E = D E D F, J, K, N = A:, Bal. = D
Number of Contacts 2 3 3 2 1 2 2 4 2 12
Contact Size 0 12 4 16 0 4 12 16 12 16
A B P J
A C D W
E F c E
G H X R K
I J d F
K P L M R N h e Y S L A
G B
j Z M
O S f T H C
T k N
g a U D
U V I
W X b
B V O
Insert Arrangement 32-5 32-6 32-7
Service Rating D A A, B, h, j = Inst.; Bal. = A
Number of Contacts 2 2 3 2 16 7 28
Contact Size 0 4 8 12 16 12 16
M
T H F A
Y N D A B
c U I A
Z O E
V J B E G B
d P
a F C D E F G
W K C
e R D C
b G H I J K
S L
X L M N
Insert Arrangement 32-8 32-9 32-10
Service Rating A D A, F = E; G = B; B, E = D; C, D = A
Number of Contacts 6 24 2 12 2 2 3
Contact Size 12 16 4 16 4 8 16
CONTACT LEGEND 16 12 8 4 0
17
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
A B N A A A B
M B 100˚ C D
C D E F G P E G H J F
L X R C B C I
Y K P L M R N
H J K K W S D D E
Z O S
J V T E T
L M N U F H U V
H F
O P W X
G G
100° Rotation
of 32-6
Insert Arrangement 32-12 32-13 32-15 32-16
Service Rating C, D, E, F, G = A; Bal. = D D D A
Number of Contacts 5 10 5 18 2 6 2 3 2 16
Contact Size 12 16 12 16 0 12 4 8 12 16
A B 13 1 1
C D E 2 16 2
F G H J 12
D A K L M 11 3 15 17 3
N O P R 23 14
S T U V W 18 4
X Y Z a 25 24 14 26 27 19
b c d e f 19 22 16 15 25
21 17 13 28 5
g h j k 30 31 20
m n p q r 12
s t u v 10 4 24 29 21 6
w x y 20 18 23
AB z AC 11 7
C B AA 9 5 22
AD AE 10 8
AF AG 8 7 6 9
Insert Arrangement 32-17 32-22 32-25 32-31
Service Rating D A A A
Number of Contacts 4 54 25 31
Contact Size 4 16 12 16
A B 90˚ M N P M
C D E F H A L R T H
J K L M N P K a b c S Y N D
B C J Z T c U I A
R S T U V W X Y j k d
H X i m f U Z O E
Y Z a b c d f g W h q r n g V J B
h i j m n p D E F p s V d P
k a F
q r s t u v A B D E W K C
C e R
w x y z AA F H v t u b G
w L
X S
BB CC G
90° CW Rotation
of 32-15
Insert Arrangement 32-48 32-52 32-53 32-56
Service Rating Inst. D t, u = E; Bal. = Inst. A
Number of Contacts 48 2 6 5 37 24 6
Contact Size 16 0 12 12 16 16 12 for #10 wire
CONTACT LEGEND 16 12 8 4 0
18
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
A Y A R H
X B
W p q Z C
B C a F S A
V n D P Z J
w T b T
D E D A U m E a
v s t c Y U
C B T k F E B
j U d N X V K
F H S i f H W
R h g J D C
P K
G N M L M L
Insert Arrangement 32-57 32-58 32-59 32-60
Service Rating ** – A A
Number of Contacts 6 2 4 40 2 15 8
Contact Size 12 0 (Coax) RG-71/U 4 (Coax) RG-161/U 16 8 (Coax) RG-161/U 16 8 (Coax) RG-124/U
or RG-179/U
A B A B
C D C D E
F G H J A B
E G H F K L M
I J N O P R
K L M R N S T U V W C D
P E
X c Y Z a
b d e f
O S g h j k F G H K L M
T m n p q r
s t u v J
U V w x y AC N P
AB z AA
W X AD AE Q R
AF AG
Insert Arrangement 32-62 32-64 32-68
Service Rating ** Inst. A
Number of Contacts 2 1 2 16 2 54 12 4
Contact Size 4 8 12 16 8 (Coax) RG-124/U 16 16 4 (Coax) RG-58C/U
20 21 1
19 22 2 1 2 3 D A
18 36 3
35 37 23 4 8 1 9 4 5 6 7
17 34 44 38 24
45 5 8 9 10 11 12
16 33 43 39 25 E
46 26 6 6 7 2
15 42
32 40 27
14 41 7 13 14 15 16
31 28
13 30 29 8 5 3
12 9 17 18 19 C B
11 10 4
Insert Arrangement 32-73 32-75 32-76 32-79
Service Rating A 8, 9 = D A D
Number of Contacts 46 2 7 19 4 1
Contact Size 16 12 8 (Coax) RG-180B/U 12 4 8
CONTACT LEGEND 16 12 8 4 0
** Consult Amphenol, Sidney, NY for service rating of power contacts.
19
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
A B A B C
A B C D E
F G H J
K L M D E F G H
N O P R
C D E S T U V W
X Y Z a
b c d e f I J K L M N
F G H K L M g h j k
m n p q r
J s t u v
N P w x y
z AA O P R S T
AB AH AC
Q R AD AE
AF AG U V W
Insert Arrangement 32-82 32-AF 32-AM 36-1
Service Rating A A A D
Number of Contacts 4 12 55 1 4 18
Contact Size 4 16 16 4/0 12 16
A A A
F
D B
E B
C B
D C
C
Insert Arrangement 36-3 36-4 36-5
Service Rating D A = D; B, C = A A
Number of Contacts 3 3 3 4
Contact Size 0 12 0 0
A A D B A
C E B D E C
F G F
F B H I J G H
K L M N I J M K L
O P R S T N O P R
U V W X S V
c W T Y U a
Y Z a b X Z
d e f g b c d e
E C h j k m f g k h j
t n
n u v p p r
m s u t
r w s v w
x y x z y
D z
Insert Arrangement 36-6 36-7 36-8
Service Rating A A A
Number of Contacts 2 4 7 40 1 46
Contact Size 0 4 12 16 12 16
CONTACT LEGEND 16 12 8 4 0 4/0
.
20
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
S M A B A B
U I C D E F G 100˚ C D E F G
Z O D
a E H J K L M N H J K L M N
V J A
P O P Q R S T U O P Q R S T U
d H
e Y B V W X Y Z a b c V W X Y Z a b c
f W K C d e f g h j k d e f g h j k
b R F m n p q r s m n p q r s
c X L w
G t u v w x t u v x
T N y z y z
100° Rotation
of 36-10
Insert Arrangement 36-9 36-10 36-11
Service Rating A A A
Number of Contacts 1 2 14 14 48 48
Contact Size 4 8 12 16 16 16
A B A
C D E F G 110˚ P N J B
H J K L M N M L
I P K C
O P Q R S T U R S
K A Q
V W X Y Z a b c
d e f g h j k J B H N L D
m n p q r s H Q C M
t u v w x G D G E
F E
y z F
110° Rotation
of 36-10
Insert Arrangement 36-12 36-13 36-14
Service Rating A N, P, Q = E; Bal. = A D
Number of Contacts 48 2 15 5 5 6
Contact Size 16 12 16 8 12 16
S A A B A B
R B 100˚ C D E D
T F G C E 110˚
Q d U C H J F G
K I N H I J
c V O L M T K L M N
P k e D P R S O P T
W R S
m U V X U V W X
j f Y Z a b c Y a b c
N E d e f g d Z e f g
b W m
h g h j t k m h j t k
M a X F n u v p n u v p
w w
L Z Y G r s r s
K H x y x y
J z z
100° Rotation 110° Rotation
of 36-7 of 36-7
Insert Arrangement 36-15 36-16 36-17
Service Rating M= D; Bal. =A A A
Number of Contacts 35 7 40 7 40
Contact Size 16 12 16 12 16
CONTACT LEGEND 16 12 8 4 0
21
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
S M A B 14 1
100˚ U I C D E F G 13 2
Z O D
H J K L M N 12 21 15
a V J E A 3
P P 20
d R S T U V W 22
Y H B 16
e X Y Z a b c 11 4
f W K C d e h j f g
b R 19 5
L F 10 17
c X G k m 18
9 6
T N 8 7
100° Rotation
of 36-9
Insert Arrangement 36-18 36-20 36-22
Service Rating A A D
Number of Contacts 1 2 14 14 2 2 30 22
Contact Size 4 8 12 16 8 12 16 12
A B C D a b A
A Z B
E F H J K C
Y c D
L M N P R S X
T U V W X Y Z k s m d E
W t n F
a b c d f g h i r
j k m n p q r V j q p f H
D C s t u v w x U i g J
y z AA AB AC T K
h
AD AH S L
B R P M
AE AF N
Insert Arrangement 36-51 36-52 36-54
Service Rating D A A
Number of Contacts 2 2 52 8 31
Contact Size 0 4 16 8 16
a b A A B C D A B
B C D E
Z C E F H J K
Y c F G
D L M N P R S T U H I J
X m E O K L M N
k s d Y Z a b P R S T
W F V W X U V W X
r t n c d f g h i j k c
Y Z a b
V H m n p q r s t d e f g
j q p f h j k m
i g u v w x y z AA AB t p
U J n u v
T K AC AE AH
h r w s
S L AD AF x y
R P M
N AJ z
Insert Arrangement 36-55 36-59 36-60
Service Rating A A A
Number of Contacts 31 8 50 3 40 7
Contact Size 16 8 for #6 wire 16 12 for #10 wire 16 12 for #10 wire
CONTACT LEGEND 16 12 8 4 0
22
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
A B C D
A A
E F H J K
L M N P R S T U
D B D B V W X Y Z a b
c d f g h i j k
m n p q r s t
u v w x y z AA AB
AC AE AH
C C AD AF
AJ
Insert Arrangement 36-64 36-65 36-71
Service Rating – – A
Number of Contacts 4 4 3 50
Contact Size 0 (Coax) RG-11/U 0 (Coax) RG-59/U, RG-62/U 12 16
RG-12/U, or RG-13/U or RG-71/U
A 1 2
48 49 31 32 3 4 5
F B 50 51 52
53 54 29 33 34 37 6 7
55 56 57 28 30 36 35 38 9 8
58 59 60 61
62 63 64 65 66 27 26 48 41 40 39 10 11
67 68 69 70
E C 71 72 73 74 75 25 47 46 42 43 13 12
G 76 77 78 79 24 23 45 44 15 14
80 81 82 83
84 85 22 21 20 18 16
86 91 87
19 17
D 88 89
90
Insert Arrangement 36-73 36-74 36-75
Service Rating – A A
Number of Contacts 7 43 1 48
Contact Size 4 (Coax) RG-62B/U 16 8 (Coax) RG-187/B 16 for #14 wire
1 3 2 A 10 1
4 5
6 7 8 F B 9 11 2
9 10 11 12
13 14 15 16 17
18 19 20 21 8 14 12 3
22 23 24 25 26
27 28 29 30 E C
31 32 33 34 35 G 13
36 37 38 39 7 4
40 41 42
43 44
45
46 47 D 6 5
Insert Arrangement 36-76 36-77 36-78
Service Rating A D A
Number of Contacts 47 7 2 12
Contact Size 16 4 16 8
CONTACT LEGEND 16 12 8 4 0
23
ACA-B
contact arrangements
front face of pin insert or rear face of socket insert illustrated
1 1
A
2 3 4 5 2 3 4 5
F B
6 7 8 9 10 6 7 8 9 10
11 12 13 14 15 11 12 13 14 15 E C
G
16 17 18 19 16 17 18 19
D
20 20
Insert Arrangement 36-79 36-80 36-83
Service Rating A A –
Number of Contacts 20 20 7
Contact Size 12 12 for #10 wire 4 (Coax) RG-58/U
S A 1
R
Q d T B
U 2 8
P c e C
k V 9
10 12
N f D
b j m 3 7
W E
M h g
a X F 4 11 6
L Z Y
K G
J H 5
Insert Arrangement 36-85 36-97 36-99
Service Rating M = D; Bal. = A C D
Number of Contacts 35 1 3 3 3 3
Contact Size 16 for #12 wire 4/0 4 8 12 16
z d e
y Q A f
x P B
O g
w Y R C h
v N c S D
X Z j
M b a T E
u L W U F k
K V
t J H G m
s n
r q p
Insert Arrangement 36-AF
Service Rating A
Number of Contacts 48
Contact Size 16
CONTACT LEGEND 16 12 8 4 0 4/0
24
ACA-B
Connector
Classes
25
ACA 3100F-B
wall mount receptacle for front panel mounting
• Receptacle with solid backshell and rear accessory threads
• Four through mounting holes or optional metric threaded holes
• Includes grommet and grommet sleeve
T M P B
THRU HOLE
R S N F
T1
THREAD K
R
S L
Inches
T
B M N Thru Hole
Shell Thread F K L + .016 + .000 P R S + .004
Size Class 2A Min. Min. Max. – .000 – .006 ± .008 ± .004 ± .012 – .000
10SL .6250-24 UNEF .409 .374 1.969 .717 .717 .110 .717 1.000 .126
14S .7500-20 UNEF .520 .374 1.969 .717 .969 .126 .906 1.181 .126
16S .8750-20 UNEF .638 .374 1.969 .717 1.079 .126 .969 1.280 .126
16 .8750-20 UNEF .638 .374 2.362 .846 1.079 .126 .969 1.280 .126
18 1.0000-20 UNEF .756 .374 2.362 .907 1.213 .157 1.063 1.378 .126
20 1.1875-18 UNEF .867 .374 2.362 .907 1.346 .157 1.157 1.496 .126
22 1.1875-18 UNEF .965 .374 2.362 .907 1.472 .157 1.252 1.614 .126
24 1.4375-18 UNEF 1.094 .374 2.560 .907 1.610 .157 1.374 1.752 .146
28 1.4375-18 UNEF 1.228 .374 2.560 .947 1.839 .157 1.563 2.000 .146
32 1.7500-18 UNS 1.488 .433 2.560 .947 2.102 .157 1.752 2.244 .169
36 2.0000-18 UNS 1.780 .465 3.150 .947 2.346 .157 1.937 2.500 .169
Millimeters
T T1
M N Thru Hole
Shell F K L + 0.4 + 0.00 P R S + 0.1 Metric
Size Min. Min. Max. – 0.0 – 0.15 ± 0.2 ± 0.1 ± 0.3 – 0.0 Thread
10SL 10.4 9.5 50 18.2 18.2 2.8 18.2 25.4 3.2 M4
14S 13.2 9.5 50 18.2 24.6 3.2 23.0 30.0 3.2 M4
16S 16.2 9.5 50 18.2 27.4 3.2 24.6 32.5 3.2 M4
16 16.2 9.5 60 21.5 27.4 3.2 24.6 32.5 3.2 M4
18 19.2 9.5 60 23.0 30.8 4.0 27.0 35.0 3.2 M4
20 22.0 9.5 60 23.0 34.2 4.0 29.4 38.0 3.2 M4
22 24.5 9.5 60 23.0 37.4 4.0 31.8 41.0 3.2 M4
24 27.8 9.5 65 23.0 40.9 4.0 34.9 44.5 3.7 M4
28 31.2 9.5 65 24.1 46.7 4.0 39.7 50.8 3.7 M5
32 37.8 11.0 65 24.1 53.4 4.0 44.5 57.0 4.3 M5
36 45.2 11.8 80 24.1 59.6 4.0 49.2 63.5 4.3 M5
All dimensions for reference only.
26
ACA 3100E-B
wall mount receptacle for front panel mounting
• Receptacle with cable clamp and telescopic bushing
• Includes grommet and grommet sleeve
• Four through mounting holes or optional metric threaded holes
T M P
THRU HOLE
R S A Z KK
T1
THREAD R L
S LL
Inches
T
M N Thru Hole
Shell L + .016 + .000 P R S + .004 Z KK LL
Size Max. – .000 – .006 ± .008 ± .004 ± .012 – .000 Max. Max. Max.
10SL 2.362 .717 .717 .110 .717 1.000 .126 .256 .894 4.720
14S 2.440 .717 .969 .126 .906 1.181 .126 .354 1.083 4.720
16S 2.756 .717 1.079 .126 .969 1.280 .126 .433 1.181 4.720
16 2.756 .846 1.079 .126 .969 1.280 .126 .433 1.181 4.921
18 3.031 .907 1.213 .157 1.063 1.378 .126 .559 1.300 4.921
20 3.031 .907 1.346 .157 1.157 1.496 .126 .622 1.476 4.921
22 3.031 .907 1.472 .157 1.252 1.614 .126 .622 1.476 4.921
24 3.346 .907 1.610 .157 1.374 1.752 .146 .843 1.705 4.921
28 3.346 .947 1.839 .157 1.563 2.000 .146 .843 1.705 4.921
32 3.346 .947 2.102 .157 1.752 2.244 .169 1.051 2.035 4.921
36 4.134 .947 2.346 .157 1.937 2.500 .169 1.248 2.283 5.315
Millimeters
T T1
M N Thru Hole
Shell L + 0.4 + 0.00 P R S + 0.1 Metric Z KK LL
Size Max. – 0.0 – 0.15 ± 0.2 ± 0.1 ± 0.3 – 0.0 Thread Max. Max. Max.
10SL 60 18.2 18.2 2.8 18.2 25.4 3.2 M4 6.5 22.7 120
14S 62 18.2 24.6 3.2 23.0 30.0 3.2 M4 9.0 27.5 120
16S 70 18.2 27.4 3.2 24.6 32.5 3.2 M4 11.0 30.0 120
16 70 21.5 27.4 3.2 24.6 32.5 3.2 M4 11.0 30.0 125
18 77 23.0 30.8 4.0 27.0 35.0 3.2 M4 14.2 33.0 125
20 77 23.0 34.2 4.0 29.4 38.0 3.2 M4 15.8 37.5 125
22 77 23.0 37.4 4.0 31.8 41.0 3.2 M4 15.8 37.5 125
24 85 23.0 40.9 4.0 34.9 44.5 3.7 M4 21.4 43.3 125
28 85 24.1 46.7 4.0 39.7 50.8 3.7 M5 21.4 43.3 125
32 85 24.1 53.4 4.0 44.5 57.0 4.3 M5 26.7 51.7 125
36 105 24.1 59.6 4.0 49.2 63.5 4.3 M5 31.7 58.0 135
All dimensions for reference only.
27
ACA 3100G-B
wall mount receptacle for front panel mounting
• Receptacle with endbell for heat shrink termination
• Does not include grommet and grommet sleeve
• Four through mounting holes or optional metric threaded holes
T M P
THRU HOLE
R S N Z BB JJ KK
T1
THREAD J
R K
S L
Inches
T
M N Thru Hole
Shell J K L + .016 + .000 P R S + .004 Z BB JJ KK
Size ± .008 ± .020 Max. – .000 – .006 ± .008 ± .004 ± .012 – .000 Min. Max. ± .008 ± .008
10SL .138 .461 1.969 .717 .717 .110 .717 1.000 .126 .303 .524 .610 .669
14S .138 .461 1.969 .717 .969 .126 .906 1.181 .126 .417 .669 .752 .791
16S .138 .461 1.969 .717 1.079 .126 .969 1.280 .126 .531 .862 .941 .925
16 .138 .453 2.362 .846 1.079 .126 .969 1.280 .126 .531 .862 .941 .925
18 .138 .453 2.362 .907 1.213 .157 1.063 1.378 .126 .575 .862 .941 1.043
20 .138 .500 2.559 .907 1.346 .157 1.157 1.496 .126 .736 1.031 1.165 1.189
22 .138 .500 2.559 .907 1.472 .157 1.252 1.614 .126 .819 1.031 1.165 1.323
24 .138 .500 2.559 .907 1.610 .157 1.374 1.752 .146 .969 1.358 1.488 1.421
28 .138 .500 2.559 .947 1.839 .157 1.563 2.000 .146 1.062 1.358 1.488 1.630
32 .138 .598 2.756 .947 2.102 .157 1.752 2.244 .169 1.311 1.717 1.882 1.913
36 .138 .598 3.150 .947 2.346 .157 1.937 2.500 .169 1.516 1.717 1.882 2.157
Millimeters
T T1
M N Thru Hole
Shell J K L + 0.4 + 0.00 P R S + 0.1 Metric Z BB JJ KK
Size ± 0.2 ± 0.5 Max. – 0.0 – 0.15 ± 0.2 ± 0.1 ± 0.3 – 0.0 Thread Min. Max. ± 0.2 ± 0.2
10SL 3.5 11.7 50 18.2 18.2 2.8 18.2 25.4 3.2 M4 7.7 13.3 15.5 17.0
14S 3.5 11.7 50 18.2 24.6 3.2 23.0 30.0 3.2 M4 10.6 17.0 19.1 20.1
16S 3.5 11.7 50 18.2 27.4 3.2 24.6 32.5 3.2 M4 13.5 21.9 23.9 23.5
16 3.5 11.5 60 21.5 27.4 3.2 24.6 32.5 3.2 M4 13.5 21.9 23.9 23.5
18 3.5 11.5 60 23.0 30.8 4.0 27.0 35.0 3.2 M4 14.6 21.9 23.9 26.5
20 3.5 12.7 65 23.0 34.2 4.0 29.4 38.0 3.2 M4 18.7 26.2 29.6 30.2
22 3.5 12.7 65 23.0 37.4 4.0 31.8 41.0 3.2 M4 20.8 26.2 29.6 33.6
24 3.5