器件描述

控制器 Wireless PB Receiver PNP, US or Canada Master Unit, 922.5 MHz frequency, Sourcing Outputs

参数
产品属性属性值
制造商:Omron
产品种类:控制器
发货限制:Mouser目前不销售该产品。
系列:A2W
商标:Omron Automation and Safety
产品类型:Controllers
工厂包装数量:1
子类别:Controllers
零件号别名:A2WRCPWC1US

A2W-RCP-WC1 US器件文档内容

Wireless Pushbutton Switch
A2W

Wireless switch using sub-GHz band

Combines wireless reliability and

ease-of-use in consideration of work

environments

• Sub-GHz band for reduced interference and better signal

propagation to difficult-to-reach areas

• Visualization of impedance to wireless transmission because of

damage or noise, using Master Unit error output

• Visualization of Slave button reception status using reception

confirmation LEDs

• Transmission distance independent of the transmission                      For the most recent information on models that have  been certified for

position of the Slave button                                                 safety standards, refer to your OMRON website.

• Visualization of configuration using PC tools * that avoid

erroneous ID registration

• Visualization of signal quality in display and usage environments using PC tools *

• 8 outputs with focus on decentralized control

• Self-power generation eliminates battery replacement and enhances safety and energy saving in the                               Slave button

• Slave button's shape allows easy use of buttons

* Release planned for April 2018

System Components

                                                                          Display board or PT, etc.

Master Unit A2W-R@@-WC1                                            PLC, etc.

                                                          Transistor output

                                                          Up to 8 points

Wireless                                                           The Slave button transmits an operation

                                                                   signal to the Master Unit, and the Master

                                                                   Unit responds a reception confirmation

                                                                   signal to the Slave button.

Slave              button         A2W-T@-WC1  (Up  to  8  points)

                                                                                                                                                      9
A2W

Model Number Structure

Model Number Structure

Slave button

A       2  W- @ @ - WC@                     @@@@                          @

              1            2         3      4                     5    6  7

    1.                           2.                                             3.                               4.

           Slave button                  Frequency (MHz)                               Protocol                          Area

           T                         C                         922.5                1  OMRON's protocol              US  United States or

                                                                                                                         Canada

    5.                           6.                                             7.

           Button type                      Button color                               Flange color

        1  Mushroom                  R                         Red                  R  Red

        2  Full guard                G                         Green                Y  Yellow

                                     Y                         Yellow               B  Black

                                     A                         Blue

                                     W                         White

                                     B                         Black

Note: This product is a wireless device that conforms to the radio regulations      of United States or Canada.

           It cannot be used outside of United States or Canada.

           For product details, please contact us separately.

Master Unit

A 2 W- @ @ @ - WC@                          @@

           1            2     3          4                     5

    1.                           2.                                             3.

           Master Unit                   Frequency (MHz)                               Output Configuration

           R                         C                         922.5                N  Sinking Outputs

                                                                                    P  Sourcing Outputs

    4.                           5.

           Protocol                         Area

        1  OMRON's protocol          US     United States or

                                                               Canada

Note: This product is a wireless device that conforms to the radio regulations of United States or Canada.

           It cannot be used outside of United States or Canada.

           For product details, please contact us separately.

10
                                                                                                                                        A2W

Ordering Information

Unit

      Type          Button type         Frequency (MHz)         Area        Button color  Flange color               Model

                                                         United States  or  Red           Black             A2W-TC-WC1 US1RB

                                                                Canada

                                                         United States  or  Green         Black             A2W-TC-WC1 US1GB

                                                                Canada

                                                         United States  or  Yellow        Black             A2W-TC-WC1 US1YB

                                                                Canada

                                                         United States  or  Blue          Black             A2W-TC-WC1 US1AB

                    Mushroom                                    Canada

                                                         United States  or  White         Black             A2W-TC-WC1 US1WB

                                                                Canada

                                                         United States  or  Black         Red               A2W-TC-WC1 US1BR

                                                                Canada

                                                         United States  or  Black         Yellow            A2W-TC-WC1 US1BY

                                                                Canada

                                                         United States  or  Black         Black             A2W-TC-WC1 US1BB

Slave button                            922.5                   Canada

                                                         United States  or  Red           Black             A2W-TC-WC1 US2RB

                                                                Canada

                                                         United States  or  Green         Black             A2W-TC-WC1 US2GB

                                                                Canada

                                                         United States  or  Yellow        Black             A2W-TC-WC1 US2YB

                                                                Canada

                                                         United States  or  Blue          Black             A2W-TC-WC1 US2AB

                    Full guard                                  Canada

                                                         United States  or  White         Black             A2W-TC-WC1 US2WB

                                                                Canada

                                                         United States  or  Black         Red               A2W-TC-WC1 US2BR

                                                                Canada

                                                         United States  or  Black         Yellow            A2W-TC-WC1 US2BY

                                                                Canada

                                                         United States  or  Black         Black             A2W-TC-WC1 US2BB

                                                                Canada

Master Unit

      Type          Frequency (MHz)                             Area        Output configuration                     Model

Master Unit                922.5                   United States or Canada          Sinking Outputs         A2W-RCN-WC1 US

                                                                                    Sourcing Outputs        A2W-RCP-WC1 US

Note: This product is a wireless device that conforms to the radio regulations of United States or Canada.

It cannot be used outside of United States or Canada.

For product details, please contact us separately.

Options (sold separately)

              Type                                       Model                                              Remarks

High-sensitivity magnetic-base antenna  A2W-AT2.5-WC1                       Frequencies: all frequencies supported, cable length 2.5 m

                                                                            Degree of protection: IP65

      Slave button holder               A2W-H-WC1                           One A2W-H-WC1 is included at purchase of a slave unit.

      Slave button strap                A2W-S-WC1

                                                                                                                                        11
A2W

Ratings

Wireless Specifications

    Item                  Slave button model                                     A2W-TC-WC1@@@@@

                          Master Unit model                                      A2W-RC@-WC1 @@

    Set frequency                               922.5 MHz

    Frequency channels                          1 channel

    Transmission power                          50 mV/m max.

    Wireless service area communications        100 kbit/s

    speed

    Communications method                       Simplex communications

    Number of wireless pushbuttons              8 max.

    connected

    Communications distance (line of sight)     Approx. 100 m outdoors (with the included pencil antenna)

    Transmission time                           Approx. 3 ms (from Slave button transmission to Slave button         reception)

    Repeater function                           Not supported.

Applicable Standards

              Area                           Wireless standards                  Safety standards                                EMC  standards

                            Approved by 47 CFR 15.205                            Approved by cULus 62368-1

    United States or        Approved by 47 CFR 15.209                            Conforms to IEC 623680-1            Conforms to      EN 301 489-1

    Canada                  Approved by 47 CFR 15.249                            Conforms to EN 62368-1              Conforms to      EN 301 489-3

                            Approved by RS-210

Conformance to EN Standards

Use a DC power line less than 3 m to conform to EN standards.

If a power line of 3 m or longer is required, extend the length at the Switching Power Supply's primary side (i.e.,  the AC power     line).

Slave button

Ratings

                       Item                                                      Specifications

    Operating force                             25 N max.

    Number of operations                        1,000,000 operations

    Vibration resistance                        Frequency: 10 to 55 Hz, half amplitude: 0.75 mm

                                                Sweep 5 min, 2 h

    Shock resistance                            1,000 m/s2

                                                Direction: 3-axis, 6 directions

    Ambient operating temperature range         -10 to +55°C (no condensation or freezing)

    Ambient operating humidity range            20% to 90%, (no condensation)

    Atmosphere                                  No corrosive gas

    Storage temperature range                   -40 to +70°C (no condensation or freezing)

    Storage humidity range                      20% to 90%, (no condensation)

    Degree of protection                        IP65

    Altitude                                    2,000 m max.

    Weight                                      100 g max.

Reception Confirmation LED

                       Item                                                                 Details

    Green                                       Reception success (received field strength “Strong”)

    Yellow                                      Reception success (received field strength “Weak”)

    Red                                         Reception failure

    Not lit                                     Slave button fault (no signal transmission from Slave button)

Operating Characteristics

                       Item                                 Code                            Unit                     Initial standard value

    Operating force                                              OF                              N                   25 N max.

    Total travel                                                 TT                         mm                       6 mm

12
                                                                                                                          A2W

Master Unit

Ratings

                     Item                                                              Specifications

                  Rated voltage              24 VDC

Master Unit       Allowable voltage range    21.6 to 26.4 VDC

power supply      Power consumption          2.4 W max.

                  Input current              0.1 A max.

                  Output points              Output 8 points

                                             One other point for error output

                  Output circuit shared      30 VDC max.

                  voltage

                  Maximum load current       50 mA per point

Output rated      Leakage current            0.1 mA max.

                  Residual voltage           2.0 V max.

                  Output logic               One-shot (500 ms)

                  Response time              30 ms or less (from Slave button transmission to Master Unit signal output)

                  Number of connected        8 max.

                  Slave buttons

Error clear       Residual voltage at short  1.5 V or less, ON

terminal          Leakage current            0.1 mA or less, OFF (current at short: approx. 7 mA)

                                             20 MΩ max. (100 VDC)

Insulation resistance                        Between the case and power supply terminals and all outputs    terminals

                                             Between all power supply terminals and all outputs terminals

                                             1,000 VAC, 1 min.

Dielectric strength                          Between the case and power supply terminals and all outputs    terminals

                                             Between all power supply terminals and all outputs terminals

Vibration resistance                         Frequency: 10 to 55 Hz, half amplitude: 0.42mm

                                             3-Directional, 120 minutes each (1 sweep, 1 min. ×120 sweeps)

                                             150 m/s2

Shock resistance                             Direction of shock: 3-axis, 6 directions

                                             Shock frequency: 3 × each direction, total 18

Ambient operating temperature range          -10 to +55°C (no condensation or freezing)

Ambient operating humidity range             20% to 90% (no condensation)

Surrounding atmospheric conditions           No corrosive gas

Ambient storage temperature range            -40 to +70°C (no condensation or freezing)

Ambient operating humidity                   20% to 90% (no condensation)

Degree of protection                         IP20

Altitude                                     2,000 m max.

Memory protection                            Non-volatile memory (Number of write operations: 1,000,000)

Weight                                       150 g (not including antenna)

                                             160 g (including antenna)

Mounting                                     DIN rail mounting

                                             Screw mounting

                                                                                                                          13
A2W

Parts Names                        and  Functions

    Slave button                                  Button

                                                  Flange

                                                  Reception Confirmation     LED

                                                  Strap  hole

    Master  Unit      AB           CDE            Q            P

            S

                                                                      R

            T                                                         U

            W                                                         V

                             FG     HI  J      K  L  MNO

    Number  Terminal  Name                               Functions                        Number  Terminal  Name                          Functions

            name                                                                                  name

    A       24 VDC                                                                                          Output     Used to register or delete the ID of the Slave

    B       24 VDC    Power                                                               R       -         settings   button to or from the output of the Master Unit.

            0V1       supply        Supply 24 VDC.                                                          switch     Also used to reset the error output without

    C                 terminals                                                                                        using the error clear terminal.

    D       0V2                                                                                             Mode       Set the operation mode of the Master Unit to

    E       CLR       Error clear   Connect the error clear terminal  to  0V      (GND).  S       -         settings   ID mode, TEST mode, and RUN mode.

                      terminal                                                                              switch

    F       OUT  1                                                                        T       -         Power LED  Lit green when the power is ON.

    G       OUT  2                                                                                          (PWR)

    H       OUT  3                  Connects the output signal line.                                                   Lit red when there is a possibility that

                                    There are two output types: sinking and               U       -         Error LED  abnormality occurs in the master unit and it

    I       OUT  4    Output        sourcing.                                                               (ERR)      will not output correctly according to the Slave

    J       OUT  5    terminals     • A2W-R@N-WC1 @@: Sinking Outputs                                                  button operation.

    K       OUT  6                  • A2W-R@P-WC1 @@: Sourcing Outputs                                                 •  RUN mode or TEST mode

                                                                                                                          It lights according to the received electric

    L       OUT  7                                                                                                        field strength of the received data.

    M       OUT  8                                                                                                        Lit green:  Received field strength is "Strong"

                                    Connects the error signal line.                                                       Lit red:    Received field strength is "Weak"

                      Error         There are two output types: sinking and                                            •  ID mode

            ERR       output        sourcing.                                                               Received      Lit green when registration or deletion is

    N                                                                                     V       -         field         success.

                      terminal      • A2W-R@N-WC1 @@: Sinking Outputs                                       strength      Flashing green when registration or

                                    • A2W-R@P-WC1 @@: Sourcing Outputs                                      LED (RCV)     deletion is failure.

                      Common                                                                                           •  When error output occurs

    O       COM       terminal for  Used as common for output and error output.                                           Lit green when the Master Unit setting data

                      outputs                                                                                             error is detected.

                                    Connect the included pencil antenna.                                                  Lit yellow when there is a possibility that the

                                    (Optional antenna A2W-AT2.5-WC1 can also                                              Master Unit will not output properly according

    P       -         Antenna       be connected.)                                                                        to the Slave button operation.

                      terminal      It transmits and receives data by wireless                                         •  RUN mode

                                    communications via the antenna.                                                       When outputting to the output terminal, the

                                    •  Delete the Slave button registration                                               corresponding output LED lit yellow.

                                       information corresponding to the output                              Output     •  TEST mode

                                       settings switch.                                   W       -         LED           It does not output to the output terminal,

                                    •  By pressing the output settings switch in the                        (OUTPUT       and the corresponding output LED lit

            -         Reset            "ERR CLR" state when an error output is                              1 to 8)       yellow.

    Q                 switch                                                                                           •  ID mode

                                       generated, error output will be reset.                                             The output LED corresponding to the

                                    •  When the power is turned ON in the                                                 output setting switch lit yellow.

                                       pressed state, it is reset to the factory

                                       setting.

14
                                                                                                                                                                                   A2W

Display Section

    LED           Color      Enabled mode                 Status                                                           Meaning

name

PWR             Green    Always enabled              Lit           During Power Supply

                                                     Not lit       No power supplied

                                                                   Received field strength monitor:

                         RUN/TEST                    Lit/Not lit   Lit green:         Received field strength is “Strong” (lit up for 500 msec)

                                                                   Lit yellow:        Received field strength is “Weak” (lit up for 500 msec)

                                                                   Not lit:           No received

                                                                   ID registration:

                                                                   Lit green:            ID registration successful (lit up for 3 s)

                Green                                              Not lit:              Data for ID registration not received

RCV             or       ID                          Lit/Not lit/  Flashing green: ID registration failed (flashes for 3 s after every 250 ms)

                yellow                               Flashing      Delete ID:

                                                                   Lit green:            ID deletion successful (lit up for 3 s)

                                                                   Not lit:              Data for ID deletion not received

                                                                   Flashing green: ID deletion failed (flashes for 3 s after every 250 ms)

                         Enabled only when                         Lit green:      Error in Master Unit setting data

                         ERR LED is lit              Lit/Not lit   Lit yellow:     Error in the most important function (wireless received, registration/verification, or output)

                                                                   All not lit:    Error in CPU initialization process during startup

                         RUN/TEST                    Lit           Data is received from the ID assigned to the corresponding output

OUTPUT                                               Not lit       Data is not received from the ID assigned to the corresponding output

1 to 8          Yellow                               Lit           Reads corresponding output settings switch values 1 to 8

                         ID                          All Lit       Reads output settings switch value DEL

                                                     All not lit   Reads output settings switch value ERR_CLR

                                                     Lit           Error in CPU initialization processing at startup, or in Master Unit setting data, or in the most important

ERR             Red      Always enabled                            function (wireless received, registration/verification, or output)

                                                     Not lit       No Master Unit error

Note: For received field strength LED (RCV) green flashing, this also flashes even when attempting to select or reset a non-registered output

        settings No. and delete or reset.

Settings Switch                                                                                    Setting Procedures

Mode Settings Switch                                                                               Slave buttons Registration Setting

Set the operation mode of the Master Unit.                                                         •   Set the output for the Slave button ID.

Factory setting: ID                                                                                •   When the mode settings switch has been set to "ID", the Slave

Operation mode                                      Function                                           button ID that has received the data during the same operation of

RUN                     Communications mode: carry out normal communications                           the Slave button three or more times within three seconds, and the

                                                                                                       contents set in the output settings switch are linked.

TEST                    Test mode: Perform installation test such as reception                     •   If you make "Wireless Push Buttons Registration setting" while

                        intensity measurement *                                                        another system is operating in the vicinity, erroneous settings may be

ID                      ID mode: Register or delete Slave buttons                                      made. Therefore, make the "Wireless Push Buttons Registration

* There is no output from the output terminal.                                                         setting" in an environment in which other systems are not operating.

Output Settings Switch                                                                             •   In the ID deletion procedure, if the received field strength LED

Register or delete the Slave button ID * for each output number of the                                 (RCV) flashes, then a non-registered port ID may be selected.

Master Unit.                                                                                       •   At Slave button registration (ID registration/deletion procedures), confirm that

Factory setting: 1                                                                                     the output LCD is lighting correctly for the output setting No. to select.

         Enabled               Other settings                                                      Wireless push button registration/deletion procedure

No.          mode              requirements                        Function                        * Using the wireless push button

                         Continuous data                  Register the ID of the target            1.  Set the mode settings switch of the Master Unit to "ID".

                         reception within a fixed         Slave button to be registered            2.  Set the output settings switch of the Master Unit.

                         period from the Slave            in the specified output                      1 to 8: The output destination is set as outputs 1 to 8.

1 to 8                   button to be registered          number                                       DEL: The information about the received ID is deleted from the

                                                          Delete IDs of all Slave                      registration list.

                         Press the Reset switch           buttons registered in the                3.  Press the wireless push button three or more times to make sure

                         (ON)                             specified output number                      that the received field strength LED (RCV) is lit.

         ID              Continuous data reception                                                 4.  Set the mode settings switch of the Master Unit to "RUN" or "TEST".

                         within a fixed period from       Delete the ID of the Slave               Wireless push button deletion procedure

                         the Slave button for which       button to be deleted from the            * Using the RESET switch

DEL                      the registration is to be        registration list                        1.  Set the mode settings switch of the Master Unit to "ID".

                         deleted                                                                   2.  Set the output settings switch of the Master Unit.

                         Press the Reset switch           Delete all IDs from the                      1 to 8: The ID information registered in outputs 1 to 8 is deleted.

                         (ON)                             registration list                            DEL: The information about all IDs is deleted from the registration list.

         ERR LED                                                                                   3.  Press the Reset switch of the Master Unit until the received field

ERR      lit red         Press the Reset switch           Execute the software reset of                strength LED (RCV) is lit.

CLR          +           (ON)                             the Master Unit                          4.  Set the mode settings switch of the Master Unit to "RUN" or "TEST".

         RCV LED                                                                                   Resetting Error Output (RCV indicator lit yellow.)

         lit yellow

* This is the identification number of the Slave button for wireless                               Using the RESET switch

communications.                                                                                    1.  Set the output settings switch of the Master Unit to "ERR_CLR".

Reset Switch                                                                                       2.  Press the Reset switch.

Execute resets of Master Unit.                                                                     Using the error clear terminal

Factory Setting: Not pressed (OFF)                                                                 1.  Connect the error clear terminal to GND.

                                                                                                                                                                                         15
A2W

Dimensions                                                                                                                                       (Unit:         mm)

Unit

Slave button

A2W-@@-WC1-@@1@@

                                 42                    65 max.                                         32

                                     40 dia.

                                                                                                                Two, M3x6

                         42                                                                                     Fine screw

                                                 26.5                         35.2

                                                                       (2.5)

A2W-@@-WC1-@@2@@

                                 42                    65 max.                                         32

                                     34.4 dia.

                                                                                                                Two, M3x6

                         42                                                                                     Fine screw

                                                 26.5                         35.2

                                                                       (2.5)

Holder                                                                                         24

A2W-H-WC1                                                                                                    Four, 5.6 dia.

One A2W-H-WC1 is

included at purchase of                                                46.6                                     24

a Slave button.

                             60.3

                                                                                    Mounting   Hole Dimensions

                                                                                                           Two, M5 screw     hole  or  5.2-dia.  mounting hole

                                           24.8

                                                                                               24±0.1

                             46.3

Strap

A2W-S-WC1                            32

                                                 Four, 3.2 dia.        Slave button mounting screws:

                                                                       Accessories (2 places)

                             32                                        Be sure to use the accessory screws.

                                                 1/4-20UNC (2 places)

                             33.5

                                     46.3                                           70.1

16
                                                                                                                             A2W

Master Unit

A2W-@@@-WC@@@

                                                                         50

                                                                         46

                           34                                                34.5

                                                                                                                     (161.5)

                                                (4.5)

                                         94 *                                           90                           (79.1)

                                                (2)

                           70                                                                                (60.8)

                                         * 108  mm at      installation  on  the  wall              (143.2)

High-sensitivity Magnetic  Base Antenna

A2W-AT2.5-WC1                                              3 dia.

                                                       1.2 dia.

                               83±3

                                     36

                                               27 dia. ±2                               2500  +100

                                                                                              –0

                                                                                                                              17
A2W

Connection

Internal Connection Diagram (Master Unit)

                            Fuse                                         Electrical circuit                                              Antenna

           24V DC

    INPUT                                      Noise filter     DC/DC converter  DC/DC converter                        RF module

                                                                (24V DC  5V DC)  (5V DC        3.3V DC)

           0V DC

                  CLR                                                                                                   Memory

                                                                                                                        (EEPROM)

                                                                                               Voltage

                                                                                               detection                                 Output circuit ×  8

                                                                                                                                         Photo coupler

                                                                                                                                                                         1

                                                                                 Power LED (PWR)                                                                            OUTPUT

                                                                                                                                                                         8

                                                                                 Error LED (PWR)                        Control section

                                                                                 Received field strength                (CPU)                                            ERR

                                                                                             LED (RCV)

                                                                                 Output LED × 8                                                                          COM

                                                                                 (OUTPUT1 to 8)

                                                                                 Operation switch

                                                                                 • Mode settings switch

                                                                                 • Output settings switch

                                                                                 • Reset switch

                                                                                                                        Serial

                                                                                                                 communications                                          PC CONN

                                                                                                                        section

Output Specifications

Operation Timing Chart                                                                                    Error Output Signal (Master Unit)

                                               Press operation

           Slave button                                                                                   Error output

                                                                Lit                                                     Power ON         Momentary         Continuously  error

                                                                                                                                         power failures

    Slave button                                                                                                 Status                  Internal transistor

    reception confirmation

    LED                                                                                                         Power is OFF.            OFF

                                                                                                           Normal operation              ON

                                                                                                           Error, or momentary           OFF

                                                                                                                 power failure

                                                                         Lit

    Master Unit RCV LED

                                                                     Master Unit output ON

                                                                     (Internal transistor ON)

    Master Unit OUTPUT

                                               500 ms

Note: If you press two or more Slave buttons simultaneously within 2

           ms, operation of the Slave button after that may not be sent to

           the Master Unit.

Output/Error Output Circuit Diagram (Master                                                               Unit)

           Output/Error output circuits diagram                          Output/Error output circuits diagram

                            (Sinking Outputs)                                    (Sourcing Outputs)

                                               OUT1                                                        COM

                                                                                                           OUT1

                                               OUT8

                                               ERR                                                         OUT8

                                               COM                                                         ERR

18
                                                                                                                                                  A2W

Recommended Ferrules and Crimp Tools

Coating peeling amount                                                                 Recommended Flat-Blade Screwdrivers

                                                          Stripping length             Use a flat-blade screwdriver to connect and remove wires.

          Recommend Wire Type                            (Ferrules not used)           Use one of the following flat-blade screwdrivers.

0.25 to 1.5 mm2/AWG 24 to AWG 16                            8 mm                       The following table shows manufacturers and models as of 2015/Dec.

2 to 2.5 mm2/AWG 14                                         10 mm                                    Side view  Front view

Applicable                                            Recommended ferrules                                              2.5 mm dia.

wire              Ferrule      Stripping

                  conductor    length (mm)    Manufactu-    Manufactu-        Manufa-

(mm2)     (AWG)   length       (Ferrules not  red by        red             ctured by

                  (mm)         used)          Phoenix       by Wago         Weidmul-

                                              Contact                           ler                   0.4 mm    2.5 mm

0.25          24  8            10             AI 0, 25-8    H0.25/12        216-301             Model                       Manufacture

                  10           12             AI 0, 25-10   ---                 ---    ESD 0,40 × 2,5           Wera

0.34          22  8            10             AI 0, 34-8    H0.34/12        216-302    SZS 0,4 × 2,5

                  10           12             AI 0, 34-10   ---                 ---    SZF 0-0,4 × 2,5 *        Phoenix Contact

0.5           20  8            10             AI 0, 5-8     H0.5/14         216-201    0.4 × 2.5 × 75 302       Wiha

                  10           12             AI 0, 5-10    H0.5/16         216-241    AEF.2,5 × 75             Facom

0.75          18  8            10             AI 0, 75-8    H0.75/14        216-202    210-719                  Wago

                  10           12             AI 0, 75-10   H0.75/16        216-242    SDI 0,4 × 2,5 × 75       Weidmuller

1/1.25    18/17   8            10             AI 1-8        H1.0/14         216-203    * The SZF 0-0,4 × 2,5 (manufactured by Phoenix Contact) can be

                  10           12             AI 1-10       H1.0/16         216-243    procured through an OMRON exclusive purchase form (XW4Z-00B).

1.25/1.5  17/16   8            10             AI 1, 5-8     H1.5/14         216-204

                  10           12             AI 1, 5-10    H1.5/16         216-244

2.5           14  10           12             AI 2,5-10     H2.5/16DS

                                              CRIMPFOX6                     Variocrim

Recommended       Crimp Tools                 CRIMPFOX6T-F  PZ6 roto        p4

                                              CRIMPFOX10S

Note: 1.      Make sure that the outer diameter of the wire coating is

              smaller than the inner diameter of the insulation sleeve of

              the recommended ferrule.

          2.  Make sure that the ferrule processing dimensions conform

              to the following figures.

                               8 to 10 mm

              2.6 mm max.      2.8 mm max.

                                                                                                                                                           19
    MEMO

20
             Terms and Conditions Agreement

Read and understand this catalog.

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have

any questions or comments.

Warranties.

(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship

                     for a period of twelve months from the date of sale by Omron (or such other period expressed in writing

                     by Omron). Omron disclaims all other warranties, express or implied.

(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT

             NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE

             PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL

             SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.

Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products

or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,

to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the

non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price

of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other

claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,

installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by

Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or

unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system

assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in

writing, are not to be construed as an amendment or addition to the above warranty.

See http://www.omron.com/global/ or contact your Omron representative for published information.

Limitation on Liability; Etc.

OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,

LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,

WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.

Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.

Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the

combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable

third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is

not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,

or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with

respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE

QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE

OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.

Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.

Performance Data.

Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining

suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it

to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.

Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice

to change part numbers when published ratings or features are changed, or when significant construction changes are made.

However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be

assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to

confirm actual specifications of purchased Product.

Errors and Omissions.

Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is

assumed for clerical, typographical or proofreading errors or omissions.
OMRON Corporation                  Industrial Automation Company                              Authorized Distributor:

Kyoto, JAPAN

                  Contact:    www.ia.omron.com

Regional Headquarters

OMRON EUROPE B.V.                              OMRON SCIENTIFIC TECHNOLOGIES INC.

Wegalaan 67-69, 2132 JD Hoofddorp              6550 Dumbarton Circle Fremont

The Netherlands                                CA 94555 U.S.A.

Tel: (31)2356-81-300/Fax: (31)2356-81-388      Tel: (1) 510-608-3400/Fax: (1) 510-744-1442

OMRON ASIA PACIFIC PTE. LTD.                   OMRON (CHINA) CO., LTD.                        © OMRON Corporation 2018  All Rights Reserved.

No. 438A Alexandra Road # 05-05/08 (Lobby 2),  Room 2211, Bank of China Tower,                In the interest of product improvement,

Alexandra Technopark,                          200 Yin Cheng Zhong Road,                      specifications are subject to change without notice.

Singapore 119967                               PuDong New Area, Shanghai, 200120, China       CSM_1_1_0118

Tel: (65) 6835-3011/Fax: (65) 6835-2711        Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200  Cat. No. A268-E1-01                      0118(0118)
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

A2W-RCN-WC1 US    A2W-TC-WC1 US2RB  A2W-TC-WC1 US2BY        A2W-TC-WC1 US2GB  A2W-TC-WC1 US1RB

A2W-TC-WC1 US1YB  A2W-TC-WC1 US1BB        A2W-TC-WC1 US1BR  A2W-TC-WC1 US1BY  A2W-TC-WC1 US1GB

A2W-H-WC1  A2W-RCP-WC1 US  A2W-TC-WC1 US2WB  A2W-TC-WC1 US2AB  A2W-TC-WC1 US2BB  A2W-S-WC1

A2W-TC-WC1 US1WB        A2W-TC-WC1 US2YB  A2W-TC-WC1 US1AB  A2W-AT2.5-WC1     A2W-TC-WC1 US2BR
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved