heavy duty power connectors sb50 housing only orange - bulk

参数

Manufacturer: Anderson Power Products
Product Category: Heavy Duty Power Connectors
RoHS: Yes
Brand: Anderson Power Products
Packaging: Bulk
Factory Pack Quantity: 500

992G7-BK器件文档内容

                             Legal Info & Global Presence

APP Global Distribution Network Includes the Following Countries Along With Many Others:
Argentina, Australia, Belgium, Brazil, Canada, Chile, China, Columbia, Denmark, France, Germany, Greece, Hong Kong, Ireland,
Israel, Italy, Japan, Mexico, New Zealand, Norway, Peru, Poland, Portugal, Singapore, Slovenia, South Africa, South Korea, Spain,
Switzerland, Thailand, Turkey, United Kingdom and United States.

APP's philosophy is to provide products and services within the trading markets of our customers. We currently serve
our worldwide customer base from customer support and manufacturing facilities in Sterling, MA, U.S.A., Warrington
UK for European customers, as well as three Asia Pacific facilities: Shenzhen, China, Shatin Hong Kong and Taichung
City 407, Taiwan (R.O.C.).
Today, as a result of innovative design and development, APP has evolved into a valued supplier for a wide variety of
markets including Back-up Power, Telecom / Datacom, Alternative Energy Generation & Distribution, Medical Equipment,
Defense, and the Material Handling Industries.
APP has established a reputation for high quality products, on-time deliveries, and excellent customer service. As a
result of modern manufacturing techniques and rigorous quality control measures, APP assures customers receive
the quality products they deserve.
As a global company dedicated to best environmental practice, APP has taken steps to meet the RoHS directive for
virtually all products. The RoHS status for individual APP products is readily accessible to customers twenty-four hours
a day, seven days a week online. APP looks forward to the challenges posed by the new technologies of the future and
will continue its century long tradition of design excellence and superior customer support to meet customers' needs.

Anderson Power Products may revise terms and conditions from time to time without notice. APP maintains this catalog as a service to its customers. The entire content
(images and text) is copyrighted 2012 and may not be distributed, downloaded, modified, reused, reposted, or otherwise used, except as provided herein, without the
express written permission of APP. You may use and download the content only for your personal, non-commercial use.
APP will use reasonable efforts to include accurate and up-to-date content in the catalog. All product information contained in the catalog including ordering information,
illustrations, specifications, and dimensions, are believed to be reliable as of the date of publishing, but is subject to change without notice. APP makes no warranty or
representation as to its accuracy. Content in the catalog may contain technical inaccuracies, typographical errors and may be changed or updated without notice. APP
may also make improvements and/or changes to the products and/or to the programs described in the content at any time without notice. Current sales drawings and
specifications are available upon request.
Neither APP nor any party involved in creating, producing, or delivering this catalog shall be liable for any direct, incidental, consequential, indirect, or punitive damages
arising out of your use of this catalog or any errors or omissions in its content.
All product names, whether or not appearing in large print or with the trademark symbol, including, but not limited to A, A in circle , Anderson Power Products, Anderson,
APP, Powerpole, SB, SBE, SBO, SBS, SBX, SPEC Pak, Saf-D-Grid, Power Clip, Power Drawer, PowerMod, are trademarks of APP, its affiliates, related companies,
licensers, and/or joint venture partners. The use or misuse of these trademarks, or any other content of this catalog, except as permitted herein, is expressly prohibited
and may be in violation of intellectual property laws, which shall be aggressively enforced.
SECTION 1                                                                   SECTION 3
    Index & Product Selector .............................. 1             Multipole Connectors ....................................... 44
    Technical Reference ..................................... 4            - SBS ................................................... 49
    Glossary ........................................................ 10   - SB50 ................................................. 57
    Engineering Reference ................................. 12             - SB120 ............................................... 62
                                                                             - SB175 ............................................... 66
SECTION 2                                                                    - SB350 ............................................... 71
    Powerpole Connectors ............................... 16               - SBE80 / SBO60 ............................... 77
                                                                             - SBE160 / SBX175 ........................... 82
- PP15 to PP45 ....................................... 20                   - SBE320 / SBX350 ........................... 88
- Powerpole Pak .................................... 23
- Powerpole PP75 ................................. 30                     SECTION 4
- Powerpole PP120 ............................... 36                           Tooling ......................................................... 95
- Powerpole PP180 ............................... 39
                                                                            SECTION 5
                                                                                 Part Number Page Reference ..................... 101

                                           Powerpole Connector Family      Multipole Connector Family
                                                                                               44
Page Number                                      16
Amps (UL) Per Pole                           Up to 350                                    Up to 450
Volts (UL) Per Pole                          Up to 600                                    Up to 600
Wire Gauge (AWG)                              20 - 3/0                                 16 - 300 mcm
Wire Gauge (mm)                             0.5 - 85.0                                   1.3 - 152
Number of Power Circuits                   1 / Stackable                           2 - 3 / Not Stackable
Ground
Auxiliary                                                                                       
PCB Mount                                                                                       
Bus Bar                                                                                         
Panel Mount                                                                                    
Blind Mate                                                                                      
Hot Plug                                         
Touch Safe                                                                                      
Strain Relief                                                                                   
Polarized Housing                                                                              
Mechanically Keyed                                                                              
Latching                                                                                       
Handle                                          
Air Supply System                                                                              
                                                                                                

All Data Subject To Change Without Notice                                   www.andersonpower.com - 1 -
SECTION 1                                       APP Custom Connector Capabilities

    Index / Prod. Selector  Anderson Power Products specializes in design and manufacture of high current connection systems to meet specific
                            customer needs. Our expertise in high amperage connections, multiple types of contact technology, and molded
                            plastic insulators allow us to provide durable, high power connections that fulfill the project requirements of OEM's.

                            We look forward to working with OEM's on their manufacturing scale projects to provide connector solutions which
                            our current product portfolio may not satisfy. APP Marketing, Engineering, Quality, Safety Agency, and Manufacturing
                            teams all contribute through the integrated product development process to create and deliver custom connectors
                            that exceed our customers' needs and meet APP high standards.

                            Contact your local customer service representative or regional sales manager to explore how APP custom design
                            and manufacturing capabilities can meet your high volume connection needs.

                            | How to Use this Catalog |

                            The information in this catalog is provided in layers to allow you to quickly find the information you are looking for.

                                 1) Selection Guides are featured at the front of the catalog and at the beginning of each product section to enable quick
                                    connector selection by electrical attributes and other features.

                                 2) A Technical Reference is provided to give important information common to all connectors in this catalog. Answers
                             to common questions, definitions of terminology, and technical charts are all included.

                                 3) Overviews at the beginning of each product main section describe the similarities and call out common features of
                             products within that section.

                                 4) Introductions to the features and benefits of each product are supplied at the beginning of each sub-product
                             section (SB50, SB120, etc).

                                 5) Specifications and Temperature Charts are shown after the main connector components in each sub-product
                                    section to provide detailed technical information (SB50, SB120, etc).

                                 6) Tooling Charts are provided at the end of each connector family (SB, SBS etc) to quickly identify the correct tooling.

- 2 - www.andersonpower.com  All Data Subject To Change Without Notice
| Product Selection Worksheet |

Prior to selecting an interconnect solution from Anderson Power Products, we recommend you gather the following    SECTION 1
information. This will aid you in quickly identifying the best product for your particular need.
                                                                                                                  Index / Prod. Selector
Amps                                       max amps at ___________ volts
            Continuous ________________    max amps ___________ seconds
            Peak _____________________

Temperature

Operating _____________                    Storage ____________

Circuit Definition

                Number of Circuits:        Wire Gauge:
                                           ________________________
Power ____________________                 ________________________
                                           ________________________
Ground ____________________                ________________________

Auxiliary ____________________

Other ____________________

Application                                 Wire to PCB   Wire to Bus Bar           Wire to Wire
             PCB to PCB
             Wire to Panel                  Other _______________________________

Mounting Method (if applicable)

PCB                                        Panel         Blind Mate

Contacts                                    Individual    Reeled
             Mating Cycles _____            Silver        Gold
             Tin                            Right Angle
             Straight

Other Features

Hot Plug                                                 Touch Safe per _______

Flame Resistance per ___________                         IP rating of __________

Sequencing                                               Strain Relief

Polarized Housing                                        Mechanical Housing Key

Latching                                                 Handle

Other _____________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

NOTES:

All Data Subject To Change Without Notice                                          www.andersonpower.com - 3 -
SECTION 1                | General Application Notes |

    Technical Reference  There are common considerations when using APP connectors. Additional considerations may apply based on the
                         particular connector being used, the application, and conditions in which the connector is being used. This information
                         is intended to provide a basic understanding and is provided for reference only. APP connectors should be assembled
                         and used according to the equipment manufacturer's instructions, as well as in compliance with local and international
                         electrical codes.

                         The maximum amperage ratings provided in the specifications are based on use of APP recommended assembly
                         tooling and the maximum wire size for the connector being used. Amperage ratings are based on not exceeding the
                         maximum operating temperature of the connector housing, factoring in an ambient temperature of 25C or 77F.
                         A wire with an appropriate insulation temperature rating should be selected to meet or exceed the total connector
                         temperature (heat rise + ambient).

                         As an example: if the maximum operating temperature for a connector operation is 105C and the ambient temperature
                         is 25C, the maximum heat rise attributable to the connector is 105C - 25C = 80C. The expected heat rise based
                         on the connector and wire size used can be estimated using the heat rise charts, but should be confirmed by testing
                         in the specific application with the specific wire to be used.

                         Connector devices are rated or derated by the wiring configuration and the environment. Factors to be considered include:
                         enclosure characteristics, connector housing and wire insulation characteristics, number of wires in an enclosed area
                         such as a raceway or conduit, as well as the ambient temperature.

                         Underwriter Laboratories Inc. amperage ratings are based on not exceeding the maximum operating temperature of
                         the connector housing. This means connectors can be extremely hot when used at the UL amperage ratings. For this
                         reason UL amperage ratings should only be applied to connectors when they are used inside an enclosure not accessible
                         to untrained persons. Canadian Standards Association ratings are based on not exceeding a 30C temperature rise
                         above ambient temperatures. For this reason CSA amp ratings are a good point of reference for connectors that are
                         user operated. APP does not recommend exceeding a 30C temperature rise above ambient temperatures for connections
                         accessible during operation to untrained persons.

                         | How to Read Temperature Charts |

                         Tempearture Rise at Constant Current Charts                                                                                      SB50
                                                                                                                                    Temperature Rise at Constant Current
                         Temperature Rise at Constant Current charts show the associated heat rise
                         as a result of applied current to the connector. An example of the SB50                            60
                         Temperature Rise chart is included to follow along with this explanation.
                                                                                                                             50
                         The chart is based on an ambient temperature of 25C (77F room
                         temperature). Accordingly if the temperature C on the Y axis of the chart is at  Temperature (C)  40
                         30C, the expected total connector temperature would be 55C.
                                                                                                                             30
                         Separate curves are shown for #6, #8, #10, and #12 AWG wire. Interpreting
                         the curves, if 50 amps are applied continuously to the connector, the heat rise                     20
                         will be 23C for #6, 35C for #8, 55C for #10, and #12 wire is not suitable for
                         this amperage.                                                                                      10

                         Where T = Temperature, heat rise is expressed as a TC.                                             0 0 10 20 30 40 50 60 70 80 90
                         T ambient - T (ambient + heat from applied current) = TC.
                                                                                                                                 Amperes Applied

                                                                                                                                  6 AWG   8 AWG
                                                                                                                                 10 AWG  12 AWG

- 4 - www.andersonpower.com                                                                                                      All Data Subject To Change Without Notice
Derating vs. Ambient Temperature Charts                                                                                    SB50            SECTION 1

Derating vs. Ambient Temperature charts show the maximum amperage                                       Derating vs. Ambient Temperature  Technical Reference
capability of a connector at a given ambient temperature. An example of                      125
the SB50 chart is included to follow along with this explanation.
                                                                           Temperature (C)  100
All data points are based on the maximum operating temperature of the
connector, most often 105C or 221F. Accordingly if the temperature C                      75
on the Y axis of the chart is at 105C, there is no amperage capability
because the connector housing is already at the maximum operating                            50
temperature.
                                                                                             25
Separate curves are shown for #6, #8, #10, and #12 AWG wire.                                     0 10 20 30 40 50 60 70 80 90 100
Interpreting the curves, at a 75C ambient temperature the maximum
amperage capability that can be applied continuously to the connector is:                         Amperes Applied
58A for #6, 46A for #8, 37A for #10, and 31A for #12 wire.
                                                                                                   6 AWG   8 AWG
                                                                                                  10 AWG  12 AWG

Notes on Temperature Rise Charts

Note that these charts are constructed using calculations based on actual test data. For this reason the chart
information may vary slightly from the safety agency ratings. Safety agency ratings and compliance with electrical
codes take precedent over these charts. The charts are designed to provide a guideline as to the connectors' capability.
Actual results can vary based on the specific wire used, crimp tooling and assembly, as well as the environment the
connector is used in.

CSA ratings are based on not exceeding a 30C temperature rise above ambient or a total temperature of 55C. This
is considered the maximum temperature to safely handle a connector at. UL ratings can be based on the operating
temperature limit of the connector. Often for APP connectors this is 105C or an 80C temperature rise above an
ambient temperature of 25C. To provide a margin of safety, the heat rise charts are limited to a 60C temperature rise.

| Compatible Wires |

Al Cu

APP connectors are designed to be crimped and/or soldered to multi-stranded copper conductor wires only.
Alternate conductor materials including aluminum should not be used. Aluminum conductors crimped into APP
contacts can result in a galvanic reaction occurring between the aluminum wire and the more cathodic metals
used in APP contacts including copper, tin, silver, and gold. Additionally softer metals like aluminum flow or
loosen from crimps much easier than copper.

Multi-stranded wire is recommended for all APP connectors and is required when crimp terminating wires or when a
connector with flat wiping contact technology is used (such as Powerpole and SB). Solid wires do not adequately
compress and retain in crimp barrels after being crimped. For this reason if solid wire is used, it should be with solder
termination only.

Solid wires also do not flex and bend as easily as multi-stranded equivalents and can act as a lever arm and impede
or alter the natural state of a flat wiping contact in the housing. This impediment or alteration to the flat wiping contact's
natural state can cause intermittency and shorts as well as higher resistance and temperature at a given amperage
than is shown in APP specifications. Mating and unmating forces may also be impacted.

All Data Subject To Change Without Notice                                                         www.andersonpower.com - 5 -
SECTION 1                | Different Contact Technologies |

    Technical Reference  Flat Wiping:
                               Same contacts on the "male" and "female" side reduce inventory costs and increase ease of assembly.
                               Low resistance connection has a large conducting surface and a high normal force in comparison to typical pin

                          and socket contacts.
                               Sacrificial tip confines damage to non-conducting area when mating or breaking under load.
                               Raised surface on the mating side of the contacts secures the connector in the mated condition, limiting the

                          need for latching on outer housings.
                               Over wiping design cleans the mating surface when mating and unmating.

                                                            - VS -

                                             Solid line                           Select points of
                                             of electrical                        electrical contact.
                                             contact.
                                                                    Pin & Socket Technology
                         Flat Wiping Technology

                         Pin & Socket:
                               Different contacts on male and female sides. Female socket contacts are typically more expensive than the

                          simple geometries of the pin contacts.
                               Often higher resistance than flat wiping connectors of the same wire size and plating due to the reduced mating

                          surface area and lower normal force. Gold plating often used to compensate and minimize resistance.
                               Best for compact connection needs such as signal and low power due to static position in housings and

                          symmetrical shape.
                               Socket contacts can catch and hold debris inside the socket body causing mating problems.

                         | Use of APP Connectors in Applications Exceeding 600V |

                         The approved voltage ratings for APP connectors are usually limited by the category under which a safety agency
                         such as UL approves our connector for use. UL typically defers to National Electric Code (NEC) on the voltage limitations
                         for any given device our connector could be used in. For most common applications NEC restricts voltage to a maximum
                         of 600V AC or DC which is what our connector voltage ratings are based on.

                         To achieve UL 1977 approval for a 600V rating, we test our connectors for dielectric withstanding voltage. The connector
                         is tested at 2 times the rated voltage of 600V plus 1000V or 2200VAC for 1 minute. For applications exceeding 600V,
                         UL / NEC / IEC may require application specific review for creepage and clearance resistance.

                         | Frequently Asked Questions |

                         Q: Can I cross mate low and high mating force contacts?

                         A: Yes, however this would not be a connection solution we have tested for safety agency approval. Additionally the
                         contacts may wear at an accelerated rate causing the mating cycle rating to be reduced. The mating and unmating
                         force expected would be somewhere in between the high and low mating force specification.

                         Q: Can I crimp multiple wires into 1 crimp barrel?

                         A: Yes, however this would not be a connection solution we have tested for safety agency approval. Particular care
                         should be used that the bundle of wires do not interfere with the movement of the contact in the housing during mating
                         and unmating (see maximum wire O.D. specification). The total circular mils of all conductor stands should be within
                         + or 5% of the wire size the contact is intended for. Twist the conductor strands together and crimp using APP
                         tooling with range taking capabilities such as the 1368 series. To crimp with other APP recommended tools, contact
                         customer service for the recommended setting or die and locator combination.

- 6 - www.andersonpower.com                                                                            All Data Subject To Change Without Notice
Q: Will the crimp tool I have for standard color-coded lugs, Mil Spec contacts, or another connector                         SECTION 1
manufacturer, work for crimping APP contacts?
                                                                                                                           Technical Reference
A: No. APP contacts generally do not conform to standard crimp barrel dimensions used for lugs, Mil Spec contacts,
or other connector manufacturers. The tooling recommended by APP must be used to ensure the performance
designed by APP is achieved. Alternate tooling will void APP warranties and can affect safety agency approvals. In
some instances Mil Spec tools are approved for crimping contacts with the dies and locators recommended by APP.
See tooling charts for specific instances, or contact customer service for more information.

Q: Can metric sized wires be used with APP contacts?

A: Yes. The majority of our crimp tooling recommendations are based on testing and verification we have performed
with AWG sized cables. Metric cables of the same or slightly smaller circular mils equivalent to the AWG wire recommended
can typically be successfully terminated in APP contacts. There is a wire conversion chart at the end of this catalog
section that can be used as a reference when converting AWG to mm sizes. The 1368 series crimp tooling has a
range taking capability that produces a reliable crimp with metric equivalents of AWG cables. Please contact customer
service for metric tooling recommendations for other APP crimp tools.

Q: Are APP connectors suitable for use in applications where the voltage exceeds 600V AC/DC?

A: Possibly. See "Use of APP Connectors in Applications Exceeding 600V", contact customer service with further
questions.

Q: How do Powerpole and Multipole connectors stay securely mated without latches?

A: The proven flat wiping technology used in these connectors features a detent or bump in the contact surface along
with powerful stainless steel springs that hold the connectors in the mated position. High mating force contacts have
a detent that is raised higher than low mating force contacts. The higher the detent, the more force is required to mate
and unmate the contacts. In many applications the detent and spring force is enough to securely hold the connectors
in the mated position without the need for latches. Latching shells, clips, or other external devices can be used to
secure flat wiping connectors in applications where shock, vibration, or cable strain may overcome the inherent force
holding the connectors together.

Q: How does APP's genderless connector design work to make a mated pair.

A: Genderless Powerpole and Multipole housings do not have a male(pin) and female(socket) side. For wire-to-wire
applications the exact same housings and contacts are used on both sides of the mated pair. If your application calls
for wire-to-PCB or wire-to-busbar connections then different contacts and possibly housings will be required on each
half (similar to male and female connectors).

To make a mated pair of Powerpole or Multipole connectors simply assemble the connectors closely following the
assembly instructions. After each connector half is fully assembled take one half and flip it over. The two halves will
mate together. Multi-row Powerpole assemblies will need to be stacked in mirror images of each other to properly
mate the correct circuits. This information is detailed at the beginning of the Powerpole section.

All Data Subject To Change Without Notice  www.andersonpower.com - 7 -
SECTION 1                | Touch Safety & Ingress Protection (IP) |

    Technical Reference  UL 1977 Section 10.2:
                         Typically required for applications where the connector is external to the end device and operating over 30V or 200A,
                         where wet conditions may be present (600V category).

                         Testing is performed using a probe that mimics a child's finger. All features of the connector are tested for live parts
                         in the unmated state (no pressure applied). A smaller 3 mm probe is then applied in the mated state to test for live
                         parts. Note that some applications may require the connector to not expose live parts to the 3 mm probe in the mating
                         interface.

                         IEC 60950:
                         From the standard for Information Technology Equipment Safety, the requirements are harmonized with UL1950. Typically
                         required for commercial and industrial applications where operators may need some degree of protection while acessing
                         or servicing equipment.

                         Testing is performed using a probe that mimics an adult finger. All features of the connector are tested for live parts in
                         the unmated state with 30 N of force applied to the probe.

                         IEC 60529:
                         Standard for Degrees of Protection Provided by Enclosures is harmonized with EN 60529.

                         Protection degree number is assigned to both solids and liquids in that order. For example: a connector with an IP20 rating
                         is protected against fingers, but has no protection against ingress of liquids. APP takes a conservative approach in rating
                         our connectors against liquid ingress and consider any meaningful water ingress to have a harmful effect.

                         Protection          Solids (First Digit)                         Liquids (Second Digit)

                         Degree Description Protected Against             Description               Protected Against

                         0                        Not Protected                                     Not Protected

                                                  Large body part such as Vertically dripping water Duration: 10 minute

                         1           > 50 mm      back of hand            (no harmful effect)       Water: 1 mm / minute rainfall

                                                                                                    Pressure: N/A

                                                  Adult fingers or similarly Tilted 15 degrees up   Duration: 10 minute

                         2           > 12.5 mm    sized objects           dripping water            Water: 3 mm / minute rainfall

                                                                          (no harmful effect)       Pressure: N/A

                                                  Typical screw drivers or Water spray up to 60     Duration: 5 minute

                         3           > 2.5 mm     large wires             degree angle              Water: 0.7 liter / minute

                                                                          (no harmful effect)       Pressure: 80-100 kN/m

                                                  Small pointy tools and Water splash from          Duration: 5 minute

                         4           > 1 mm       small wires             any direction             Water: 10 liter / minute

                                                                          (no harmful effect)       Pressure: 80-100 kN/m

                                                  Complete physical       Water jet from any        Duration: 3+ minute

                         5           Dust protected protection, no functional direction             Water: 12.5 liter / minute

                                                  interference from dust  (no harmful effect)       Pressure: 30 kN/m @ 3 m distance

                                                  Complete physical       Strong water jet from Duration: 3+ minute

                         6           Dust sealed  protection and sealed   any direction             Water: 100 liter / minute

                                                  from dust ingress       (no harmful effect)       Pressure: 100 kN/m @ 3 m distance

                                                                          No ingress of water       Duration: 30 minute

                         7                                                in harmful quantity       Water: Immersion
                                                                          when immersed up          Pressure: 1 m depth

                                                  N/A                     to 1 m depth

                                                                          No ingress of water       Duration: Mfg. specified

                         8                                                in harmful quantity       Water: Immersion
                                                                          when subject to tests     Pressure: 1+ m depth. Mfg. specified

                                                                          in excess of condition 7

- 8 - www.andersonpower.com                                                                                        All Data Subject To Change Without Notice
| Preventative Maintenance |

Damaged connectors, contacts and cables may present hazards, resulting in inefficient battery and charger operation.           SECTION 1
To avoid these problems, conduct the following maintenance checks at least once annually. When you see a problem,
take corrective action immediately.                                                                                          Technical Reference

1. Dirty Connectors
When engaged and disengaged, the contact surfaces of Anderson SB Connectors "over wipe," thus providing
a self cleaning action. To ensure the continued benefit of this feature, clean the contact surfaces and lubricate
the connector. Use a "white" lithium grease, which may be obtained from hardware stores and automotive parts
suppliers.

2. Melting Connectors
Connector housings overheat and melt for many reasons. To prevent this:

     A. Examine the crimp between cable and contact. Ensure the crimp tooling recommended by APP has been
used. Improper crimping, corrosion, and broken wires result in unnecessary resistance causing the contact
to heat up.

     B. Check contact surfaces for signs of "pitting" caused by dirt or disengaging connectors under load. One
badly pitted contact, particularly in a connector attached to a battery charger, can lead to pitting on surfaces
of other contacts. If not corrected, this can result in an epidemic of bad connectors throughout a fleet of electric
vehicles and in chargers and batteries.

     C. Check to see if batteries are being disconnected while the charger is still on. This causes the contacts to arc
at the tips, resulting with progressive pitting and silver removal from tip to crown. If this practice is occurring,
discontinue it now to avoid major repairs in the future.

3. Other Conditions
If any of the following conditions exist, the connector housing, contact and/or cable should be replaced immediately.

     A. Housing: Cracks, missing pieces, evidence of excessive heat, discoloration. You may consider replacing the existing
housing with a Chemical Resistant equivalent for improved durability against UV rays and common solvents and
hydrocarbons.

     B. Contacts: Pitting, burns, corrosion, excessive wear, cracked crimp barrels,
discoloration.

C. Cable: Exposed copper near housing, cracked cable, peeling or frayed insulation.

D. Handles: Loose attachment and signs of damage as missing or loose hardware
   and cracked or broken plastic (Handles should be used for connectors that are
   hard to reach or move.)

     E. Cable Clamps: Loose attachments, signs of abraded cable jacket, missing      Uncrimped Good  Damaged
or loose hardware. (Cable clamps should be used to relieve strain on                Contact         Contact
unmounted cable.)
                                                                                                       B
                                           A

All Data Subject To Change Without Notice                                            www.andersonpower.com - 9 -
SECTION 1     Amp / Ampere: Measurement increment of electric current. Abbreviated         Flammability: The measure of a material's ability to support combustion.
              as "I".                                                                      Often tested per UL94.
    Glossary
              Applicator: A semi-automatic termination machine consisting of an            Flat Wiping: The sliding action which occurs when contacts are mated.
              upper and lower half that is used to crimp contacts onto wire. Used in       Wiping has the effect of removing small amounts of contamination from
              conjunction with an electrical/ mechanical press.                            the contact surfaces, thus establishing better conductivity.

              AWG: American Wire Gauge. A standard system for designating wire             Genderless: See "Hermaphroditic"
              diameters.
                                                                                           Heat Rise: Temperature rise associated with the electrical load applied
              Blindmate: To join two connector halves in a normal engaging mode            to a mated connection.
              without visual orientation.
                                                                                           Hermaphroditic (Genderless) Connector: A connector in which both
              Busbar: Three dimensional constructions enabling electrical distribution     mating members are exactly alike at their mating face. There are no
              of current in power electronic modules. Typically constructed of cop-        male or female members, but designs provide correct polarity.
              per, busbars are most frequently used in power dense applications
              where the busbar offers a cost or space savings over wire.                   Hot Plug / Hot Swap: Live connector insertion / extractions.

              Color Coding: A system of identification for terminals and related devices.  IEC: International Electrotechnical Commission, a standard writing
                                                                                           organization.
              Contact Resistance: The electrical resistance of metallic surfaces
              at their interface in the contact area under specified conditions when       Insulation Resistance: Ratio of applied voltage to the total current
              carrying a specified test current.                                           between the two electrodes in contact with a specific insulation.

              Contact Retention: Minimum axial load in either direction which a            IP: Ingress Protection, a standard per IEC 60529 for measurement of
              contact must withstand while remaining firmly fixed in its normal position   ingress for solids and liquids into an enclosure.
              within a housing.
                                                                                           Locator / Positioner: Device for positioning contacts into crimping dies.
              Crimp Retention: The axial load which a contact can withstand without
              separation from the wire.                                                    Make-First / Break-Last (Premate): Sequencing of contact(s) so
                                                                                           that they engage prior to the main power contacts. Typically used
              Crimp Termination: A connection in which a metal sleeve is secured           for ground / positive earth / neutral positons as a protective measure
              to a conductor by mechanically deforming the sleeve with presses or          against excess currents, short-circuits, and ground faults.
              automated crimping machines, eliminating the need for solder. Not
              suitable for solid (non-stranded wires).                                     Make-Last / Break-First (Postmate): Sequencing of contact(s) so that
                                                                                           they engage after the main power contacts. Typically used for signal or
              CSA: Canadian Standards Association, a safety standard writing and           auxiliary power positions to ensure communications are not started or
              testing organization.                                                        power circuits switched on until the power contacts are fully engaged.

              Cycle Controlled: To determine if repetitive on/off conditions result        Mating Force: Force required to join two connector halves in a normal
              in degrading the contact system which may lead to failures such as           engaging mode.
              "thermal run away".
                                                                                           Modular: Refers to similar parts or modules used as building blocks. A
              Detent: A bump or raised section projecting from the surface of a contact    modular connector is one in which similar or identical sections can be
              for keeping the contact in position relative to another and released by      assembled together to provide the appropriate connector type or size
              greater force.                                                               for the application.

              Dielectric Strength (Withstanding Voltage): The highest potential            Ohms: Measurement increment of resistance.
              difference (voltage) that an insulation material of given thickness can
              withstand for a specified time without occurrence of electrical breakdown    Operating Temperature Range: Connector temperature rating
              through its bulk.                                                            established by materials used, plastic, finish, and the base metal.
                                                                                           Applying an electrical load will result in a temperature rise that is
              Finger Proof: A connector intended for usage external to the end             additive to the operating ambient.
              equipment shall have live parts protected against exposure to contact
              by persons when assembled, installed, and mated as intended, as              PCB: Acronym for Printed Circuit Board
              determined by UL Articulated probe.
                                                                                           Polarization: A technique of eliminating symmetry so that parts may
                                                                                           only be mated one way.

- 10 - www.andersonpower.com                                                               All Data Subject To Change Without Notice
Pulse (Surge) Current: Highest instantaneous current that will run          Storage Battery: A voltaic battery consisting of two or more storage       SECTION 1
through a system.                                                           cells. Energy is accumulated by chemical activity in the charging
                                                                            process and released on demand in the form of electric current.          Glossary
REACH: The European Community Regulation on chemicals and their
safe use. It deals with the Registration, Evaluation, Authorization and     Strain Relief: A means of termination or installation that reduces the
Restriction of Chemical substances.                                         transfer of mechanical stress from the conductor.

Reducing Bushing: Separate tubular sleeve used to downsize the              Termination: Means of joining contacts to a conductor.
diameter of a crimp barrel to accept a smaller size wire.
                                                                            Touch Safe: See "Finger Proof"
Reeled Contacts: Contacts attached to a feeder strip for use in a high
volume crimping tool.                                                       Turret / Positioner: See "Locator"

Resistance: The opposition to the passage of an electric current            TUV: The TV Rheinland Group is provider of technical services that
through that element. Abbreviated as "R".                                   certifies products to standards written by other organizations.

RoHS: Restriction of Hazardous Substances Directive. The European           UL: Underwriters Laboratory, a safety standard writing and testing
directive on the restriction of the use of certain hazardous substances     organization.
in electrical and electronic equipment.
                                                                            Volts: Measurement increment of electric potential. Abbreviated as "E".
Sacrificial Tip: An area of a contact system that absorbs electric arching
to limit damage to the actual mating surface of the contacts.               VDE: A German standard writing and testing organization responsible
                                                                            standards and safety specifications covering the areas of electrical
Self-Wiping: The sliding action which occurs when contacts are mated.       engineering, electronics and information technology.
Wiping has the effect of removing small amounts of contamination
from the contact surfaces, establishing better conductivity.                Watt: Measurement increment of electric power. Abbreviated as "W".

Spring Loaded: A means of providing contact normal force with the
use of a mechanical spring.

All Data Subject To Change Without Notice                                   www.andersonpower.com - 11 -
SECTION 1                  | Conversion Chart for American Wire Guage to Metric System |

    Engineering Reference                                   Approximate                               Approximate

                           AWG   Metric  Circ.       Equivalent Wire Diameter  AWG   Metric Circ.  Equivalent Wire Diameter
                           Size  mm     Mils                                  Size  mm Mils
                                                     Circ.Mils in.  mm          1/0                Circ.Mils in.  mm
                              -   0.5       -                                   2/0
                             20     -    1020         937   0.032   0.81             -    106mcm*  -  0.373 9.46
                              -  0.75                   -   0.036   0.91         -
                             18     -       -               0.039   0.99        3/0  -    133mcm*  -  0.419 10.60
                              -   1      1620        1480
                             16     -                                            -   70   -        138.1mcm 0.430 10.90
                              -   1.5       -                                   4/0
                             14     -    2580        -      0.046 1.16               -    168mcm*  -  0.471 12.00
                              -   2.5                                            -
                             12     -       -        1974   0.051 1.30           -   95   -        187.5mcm 0.504 12.80
                              -    4     4110                                    -
                             10     -                -      0.051 1.29           -   -    212mcm*  -  0.528 13.40
                              -    6        -                                    -
                              8     -    6530        2960   0.063 1.60           -   120  -        237.8mcm 0.567 14.40
                              -   10                    -   0.073 1.84           -
                              6     -       -               0.081 2.06           -   -    250mcm   -  0.575 14.60
                              -   16     10380       4934   0.092 2.32           -
                              4     -                   -                        -   150 300mcm    -  0.630 16.00
                              -   25        -                                    -
                              2     -    16510                                   -   -    350mcm   -  0.681 17.30
                              -   35
                              1     -       -        7894   0.102 2.59           -   185  -        365.1mcm 0.700 17.80
                              -   50     26240                                   -
                                                     -      0.116 2.93           -   -    400mcm   -  0.728 18.50
                                            -                                    -
                                         41740       11840  0.126 3.21               240  -        473.6mcm 0.801 20.30

                                            -           -   0.146   3.70             -    500mcm   -  0.814 20.70
                                         66360       19740  0.162   4.12
                                                            0.184   4.66             300  -        592.1mcm 0.891 22.60
                                            -           -   0.204   5.18
                                         83690       31580                           -    600mcm   -  0.893 22.70

                                            -                                        -    700mcm   -  0.964 24.50

                                                     -      0.232 5.88               -    750mcm   -  0.999 25.40

                                                     49340  0.260 6.60               400  -        789.4mcm 1.026 26.10

                                                     -      0.292 7.42               -    800mcm   -  1.032 26.20

                                                     69070  0.305   7.75             500           986.8mcm 1.152 29.30
                                                        -   0.332   9.43
                                                            0.365   9.27             -    1000mcm  -  1.153 29.30
                                                     98680
                                                                                     625  -        1233.7mcm 1.287 32.70

                           * Rounded for simplicity

                           NOTE: The above wire diameters and circular mils are based on an average of the most commonly available wires. The wire
                           manufacturer's specification should be referenced for information specific to the wire being used.

- 12 - www.andersonpower.com                                                                       All Data Subject To Change Without Notice
| Volts Amps Ohms Watts Conversion |                                                                       SECTION 1

                                                                                                               Engineering Reference

WR                                         E                        E                   EI

                                           R                        I

W                                          W                        W                   I R

I                                                         R         I

IR                                         W                        E                  E
                                                                    W                   R
                                           E

Volts = Watts x Ohms                       Amperes = Volts          Ohms = Volts        W atts = Volts x Amps
Volts = W atts                                               Ohms               Amps

            Amps                           Amperes = Watts          Ohms = W atts W atts = Amps x Ohms
Volts = Amps x Ohms                                          Ohms               Amps

                                           Amperes = Watts          Ohms = Volts       W atts = Volts
                                                             Volts              W atts              Ohms

Wattage Varies Directly as a Ratio of Voltages Squared.

W = W E x                            Total Watts
             E                            Volts x 1.732

3 Phase Amperes =

All Data Subject To Change Without Notice                                               www.andersonpower.com - 13 -
                                                          | Standard to Metric Conversions |

SECTION 1                          Approximate Conversions                             Approximate Conversions
                                                                                          From: SI / Metric Units
    Engineering Reference         From: Standard / US Customary
                                                                                     To: Standard / US Customary
                                   To: SI / Metric Units

                                   When         Multiply                                When         Multiply
                                    You             By                                   You
                           Symbol  Know                       To Find Symbol    Symbol               By        To Find     Symbol
                                                                                        Know
                                                                                                                               in
                                                LENGTH                                               LENGTH                     ft

                           in      inches       25.4          millimeters mm    mm      millimeters  0.039     inches

                           ft      feet         0.305         meters       m    m       meters       3.28      feet

                                                AREA                                                 AREA

                           in 2    square                     square       mm2  mm 2 millimeters     0.0016    square      in2
                                                                            m2
                                   inches       645.2         millimeters                                      inches
                                                                            mL
                           ft 2    square feet  0.093         square        L   m2      square       10.764 square feet    ft2
                                                              meters        m3          meters
                                                                             g
                                                VOLUME                      kg                       VOLUME

                                   fluid                                    oC  mL      milliliters  0.034     fluid       fl oz

                           fl oz   ounces       29.57         milliliters    N                                 ounces
                                                                           kPa
                           gal     gallons      3.785          liters           L       liters       0.264     gallons     gal
                                                0.028          cubic
                           ft 3    cubic feet                 meters            m3      cubic        35.314    cubic feet  ft3
                                                                                        meters

                                                MASS                                                 MASS

                           oz      ounces       28.35         grams             g       grams        0.035     ounces      oz

                           lb      pounds       0.454         kilograms         kg      kilograms    2.202     pounds      lb

                                            TEMPERATURE                                         TEMPERATURE

                           oF      Fahrenheit (F-32) x 5 / Celsius              oC      Celsius 1.8C + 32 Fahrenheit       oF

                                                9
                                                or

                                                (F-32) / 1.8

                                  FORCE and PRESSURE or STRESS                       FORCE and PRESSURE or STRESS

                           lbf     poundforce   4.45          newtons           N       newtons      0.225     poundforce    lbf
                                                                                                                           lbf/in2
                           lbf/in 2 poundforce  6.89          kilopascals       kPa     kilopascals  0.145     poundforce

                                   per square                                                                  per square

                                   inch                                                                        inch

- 14 - www.andersonpower.com                                                                                 All Data Subject To Change Without Notice
                                           | Scratch Pad |

                                                              SECTION 1

                                                            Engineering Reference

All Data Subject To Change Without Notice                   www.andersonpower.com - 15 -
                                                         

                      Powerpole Connectors
                      - PP15 to PP180

SECTION 2                                                   This versatile connector series invented by Anderson Power
                                                            Products meets a wide range of power connection needs.
   Powerpole Family                                        There are four basic housing sizes in the Powerpole
                                                            product family that allow specific amperage or wire size
                                                            needs to be filled in the most compact footprint. Powerpole
                                                            can handle up to 350 amperes per pole and accommodate
                                                            wire ranges of #20 AWG (0.5 mm) to 3/0 (70 mm). A wide
                                                            range of colored housing options can be stacked together to
                                                            create a proven reliable custom connector. These housings
                                                            can be used with different contacts to create wire-to-wire,
                                                            wire-to-board, or wire-to-busbar connections. The
                                                            Powerpole combines high quality materials and a cost
                                                            effective innovative design to allow powerful versatility.

                                                                                Stackable Modular Housings
                                                                                Available in four sizes to right
                                                                                size your connection need

                                                                                                                         Color Coded Housings
                                                                                                                         Help ensure that connectors
                                                                                                                         are assembled and mated
                                                                                                                         correctly

                      Genderless Housings
                      Provide simplified assembly
                      and minimize the number of
                      components

                                                            Low Resistance Connection
                                                            Silver or tin plated contacts
                                                            inside housings that strongly
                                                            force the contacts together

                      Self Securing Design              Hot Plugging AC or DC
                      Stainless steel springs create    Contacts feature a sacrificial
                      a robust force between the        tip that allow high current
                      contacts that holds the con-      circuit interrupt
                      nector in the mated condition,
                      but allows it to be quickly dis-
                      connected

- 16 - www.andersonpower.com                                                            Connection Versatility
                                                                                        Contacts for wire, PCB,
                                                                                        or busbar all fit into the
                                                                                        same housings

                                                                                                                                    All Data Subject To Change Without Notice
| POWERPOLE FAMILY SELECTION GUIDE |

Powerpole Size PP15 to 45 Page # PP75 Page #                              PP120 Page # PP180       Page #
                                                                                                       39
Connector Types      Standard                          20  Standard    30  Standard  36   Standard     40

                     Finger Proof 20                       Locking     31                 Busbar

                     PCB                               21  Busbar      31

                     Ground                            21  PCB         31

                     Power Pak 23

Amps (UL) Per Pole                         0 to 55            120               240            350
                                                              600               600            600
Volts (UL) Per Pole                        600               16 - 6           6 - 1/0        10 - 3/0
                                                           1.3 - 13.3       13.3 - 53.5     5.3 - 85.0
Wire Gauge (AWG)                           20 - 10                         1 / Stackable                      SECTION 2
                                                                                          1 / Stackable
Wire Gauge (mm)                           0.05 - 6.0                                                       Powerpole Family
                                                                                                      
Number of              1 / Stackable                       1 / Stackable                              
Power Circuits                  
Ground                                                                                                
PCB Mount                                                            
Busbar                                                                                                
Panel Mount          Powerpole Pak
Blind Mate                                                            
Hot Plug                        
Touch Safe                                                            
Polarized Housing               
Latching             Powerpole Pak
Strain Relief        Powerpole Pak

Actual Size - Connector Half

                     ............................... Powerpole Housings ...............................

                     PP15/45 PP75                                          PP120          PP180

All Data Subject To Change Without Notice                                                           www.andersonpower.com - 17 -
Powerful Versatility

- Create Your Own Custom Connector from Durable Proven Components

  Powerpole connectors can be easily customized to each power connection need. Choose from a wide range of
  colored housings and stack them together into a multiple position connection. Durable silver or tin plated contacts
  crimp and poke into housings and are available for a broad range of wire sizes. PCB and busbar contacts can also
  be simply snapped into place using the same housings. Pre-mate ground / power housings and contacts can be
  used for safety or sequencing and stack along with standard housings.

How to Create Mating Blocks of Stacked Powerpole Connectors
A Single Row Assembly such as the 1x3 shown below will mate to itself. If an assembly has more than one row
such as the Two Row Assembly 2x1 shown below, then a different mirror image mating assembly is required.

Single Row Assembly 1x3                                      Two Row Assembly 2x1

SECTION 2

   Powerpole Family

                                                                                                                                   Column 1
                                                                                                                                                    Column 2
                                                                                                                                                                     Column 3
To Create a Mirror Image Mating Assembly:
When mating blocks are viewed with their hoods in the respective orientation (down or up), the column position of
connectors is unchanged. The rows themselves are mirror images of each other. So in the below example, what
is column 1 on side A, is column 3 on side B.

Side A Hood Down                                                                                                                                                                        Side B Hood Up
                                             Column 3
                            Column 2
           Column 1

                                                       C  B  A                                                                                                                 Hood Up

Hood Down                     A  B  C

                              DEF                      FED

                              GHI                      I  HG

- 18 - www.andersonpower.com                                                                                                                                                   All Data Subject To Change Without Notice
Use the Same Housings for Wire, PCB, or Busbar Connections
The Powerpole connection system allows the same housings to hold different contacts for terminating to wire,
printed circuit boards, or busbars. See some of the many ways Powerpole components can be assembled to
create a custom connection solution.



                                           Wire-to-Wire

                                                                                                                 SECTION 2

                                                                                                               Powerpole Family

                                           Wire-to-PCB

                                           Wire-to-Busbar

All Data Subject To Change Without Notice                  www.andersonpower.com - 19 -
                          Powerpole Connectors                                                 PP15-45 series are the smallest Powerpole housings. They can be
                          - PP15 to PP45 :                                                      used for wire-to-wire or wire-to-board applications. Wire sizes from
                          up to 55 Amps                                                         #20 AWG (0.5 mm) to #10 (6 mm) offer power capabilities up to 55
                                                                                                amps per pole. Finger proof housings and the ability to incorporate
SECTION 2                                                                                       first-mate last-break ground connectors enhance the capabilities of
                                                                                                this Powerpole series.
   Powerpole PP15 to 45
                                                                                                High Power Density

                                                                                                 Up to 55 amps in a compact footprint

                                                                                                Wire-to Wire & Wire-to-Board Configurations

                                                                                                 Wire & PCB contacts can be used in the same housings

                                                                                                Finger Proof Housings Available

                                                                                                 Protects against accidental contact with live circuits

                          | PP15-45 ORDERING INFORMATION |

                          PP15-45 Finger Proof Housings
                          Improved on the original APP design by adding ribs to mating interface to protect against accidental

                          contact with live circuits. Meets the requirements of UL1977 section 10.2 and is rated IP20. Will not

                          m ate w ith standard housings.                                                                  PP15-45 Finger Proof & Standard & Ground Housing Dimensions

                          Description    ------------ Part Numbers ------------
                                                                                    200 ..... Finger Proof                [ 7.9 ] Front View
                          Minimum Quantity ... 2,500                                     R ib Fea ture                    0.31                                             Mated Length

                          Red            1327FP-BK        1327FP                                                                              [ 26.6 ]
                          Green          1327G5FP-BK                                                                                           0.97
                                                          1327G5FP

                          Black          1327G6FP-BK      1327G6FP                                                               [ 7.9 ]                                   [ 8.4 ]
                          White          1327G7FP-BK      1327G7FP                                                               0.31                                      0.33
                          Blue           1327G8FP-BK      1327G8FP
                                                                                                                                              [ 41.2 ]
                          Yellow         1327G16FP-BK 1327G16FP
                                                                                                                                                        1.62

                          PP15-45 Standard Housings                                                              45A Premate Ground Housings

                          The original housing design has an open interface and is available                     Green housings are keyed to prevent accidental mating

                          in a wide array of colors. Will not mate with finger proof housings.                   with standard or finger proof Powerpole housings.

                          Description    ------- Part Numbers ------                                             Description     ------- Part Number -------

                          Minimum Quantity ... 2,500      200 ...                                                Minimum Quantity ... 2,500   200 ...

                          Red            1327-BK          1327                                                   Green           1827G1-BK 1827G1
                          Green          1327G5-BK        1327G5
                          Black          1327G6-BK        1327G6
                          White          1327G7-BK        1327G7
                          Blue           1327G8-BK        1327G8
                          Yellow         1327G16-BK       1327G16
                          Orange         1327G17-BK       1327G17
                          Gray           1327G18-BK       1327G18
                          Brown          1327G21-BK       1327G21
                          Pink           1327G22-BK       1327G22
                          Purple         1327G23-BK       1327G23

                          PP15-45 Tin Plated Power Contacts

                          Offer cost effective performance up to 1,500 mating cycles. See specifications and temperature

                          charts for amperage ratings by wire size.

                                                                                                            Dimensions

                                                          Mating Loose Piece Reeled                         -A-

                          Barrel AWG     mm              Force -------- Part Numbers ------- inches mm

                          Minimum Quantity .......................................  200  5,000 .........................

                          Open 14 to 10 K* 2.1 to 5.3 High 269G3-LPBK 269G3 0.21 5.33

                          Open 14 to 10 K* 2.1 to 5.3 Low 261G2-LPBK 261G2 0.20 5.08                                                          Open Barrel Contact

                          Open 14 to 10 SF* 2.1 to 6.0 High 201G1H-LPBK 201G1H 0.24 6.10

                          Open 14 to 10 SF* 2.1 to 6.0 Low 200G1L-LPBK 200G1L 0.24 6.10                                                       [ 17.27 ]                    [ 6.35 ]
                                                                                                                                                0.68                        0.25
                          Open 16 to 12  1.3 to 3.3 High 269G1-LPBK 269G1 0.18 4.57

                          Open 16 to 12  1.3 to 3.3 Low 261G1-LPBK 261G1 0.18 4.57

                          Open 20 to 16  0.52 to 1.3 High 269G2-LPBK 269G2 0.16 4.06                                                                    [ 3.81 ]
                                                                                                                                                         0.15
                          Open 20 to 16  0.52 to 1.3 Low 262G1-LPBK 262G1 0.16 4.06                                                                                     A

                          Open 20 to 16 SF* 0.52 to 1.5 Low 200G2L-LPBK 200G2L 0.20 5.08

                          K* - For #10 AWG class K stranded wire or smaller. For larger wires use superflex contacts.
                          SF*- Indicates wires with high stranding such as Super Flex.

- 20 - www.andersonpower.com                                                                                                                  All Data Subject To Change Without Notice
PP15-45 Silver Plated Power Contacts                                                                                                                                    Open Barrel Contact

Maximize performance by offering up to 10,000 mating cycles and are recommended for circuit interrupt or                                                                [ 17.27 ]
hot plug applications. See specifications and temperature charts for amperage ratings by wire size. Only closed                                                           0.68
barrel contacts are suitable for soldering.

                                                                                                                     Dimensions                                                                   [ 6.35 ]
                                                                                                                                                                                                   0.25

                                           Mating                  Loose Piece            Reeled                     -A-          - B -

Barrel AWG              mm                Force -------- Part Number ---------           Part Number                inches mm inches mm                                         [ 3.81 ]  A
                                                                                                                                                                                  0.15
Minimum Quantity .......................................... 5,000            200           5,000                     .................................................

Open         14 to 10 K* 2.1 to 5.3        Low                       -      261G3-LPBK    261G3                      0.20 5.08 -  -
Open                                       High                      -              -     201G3H
Open         14 to 10 SF* 2.1 to 6.0       Low                       -                    200G3L                     0.24 6.10 -  -
Open                                       Low                       -      200G3L-LPBK   261G4
Open         14 to 10 SF* 2.1 to 6.0       Low                       -      261G4-LPBK    262G2                      0.24 6.10 -  -                                     Closed Barrel Contact
Open                                       Low                       -      262G2-LPBK    200G4L
Closed       16 to 12   1.3 to 3.3         Low                  1331-BK                                              0.18 4.57 -  -                                      [ 16.26 ]
Closed                                     Low                  1332-BK             -         -                                                                             0.64
             20 to 16   0.52 to 1.3                                         1331              -                      0.16 4.06 -  -                                                               [ 7.35 ]
                                                                            1332                                                                                                          B        0.29
             20 to 16 SF* 0.52 to 1.5                                                                                0.20 5.08 -  -                                          [ 3.81 ] A

             16 to 12   1.3 to 3.3                                                                                   0.15 3.81 0.10 2.54                                       0.15

             20 to 16   0.52 to 1.3                                                                                  0.12 3.05 0.07 1.78                                                                              SECTION 2

K* - For #10 AWG class K stranded wire or smaller. For larger wires use superflex contacts.                                                                                                                         Powerpole PP15 to 45
SF*- Indicates wires with high stranding such as Super Flex.

45A Premate Ground Wire Contacts                                                                                                           Open Barrel Premate Contact

Tin or silver plated contacts are rated for ground or power. Hand tools are available for loose piece                                      [ 3.6 ]                        [ 19.1 ]
contacts. Reeled contacts can be used with high volume press and applicator tooling. Tin contacts                                          0.14                             0.75
are rated for up to 1,500 mating cycles. Silver contacts are rated up to 10,000 mating cycles.
                                                                                                                                                                        [ 6.4 ]
                                                                                  Reeled                                                                                0.25

                                           Mating Loose Piece Part

Type         AWG        mm                Force - Part Numbers - - Numbers -                                                                                               [ 6.1 ]
                                                                                                                                                                             0.24
Minimum Quantity .............................................     200               5,000 .....                                                                        [ 6.1 ]
                                                                                                                                                                        0.24
Open, Tin    14 to 10 2.1 to 6.0 Low                            1830G1-LPBK       1830G1
                                                                1830G2-LPBK       1830G2
Open, Silver 14 to 10 2.1 to 6.0 Low

25A Right Angle PCB Contacts Tin Plated

Suitable for right angle applications up to 25A per pole. Tin plating enhances solderability.
C anno t be mixed with 45A PCB contacts. For mating with wire contacts only.

                                                                         Dimensions

           Mating       Loose Piece                             -A-                  -B-

Row          Force ------- Part Numbers ------- inches mm inches mm

Minimum Quantity ... 1,000                 100                  ...................................................

Top        Low         1377G1-BK      1377G1 0.59 14.80 1.52                         38.60                                                     A
Bottom     High        1317G1-BK      1317G1                                         34.50                                                                                            [ 9.9 ]
Top        Low         1377G2-BK      1377G2 0.29 7.20 1.36                          30.70                                                                                             0.39
Bottom     High        1317G2-BK      1317G2                                         25.70
           Low         1377G11-BK     1377G11 0.59 14.80 1.21                                                                                                      B
           High        1317G11-BK     1317G11                                                                                     Use mounting staples with right angle contacts
           Low         1377G12-BK     1377G12 0.29 7.20 1.01                                                                      (see accessories).
           High        1317G12-BK     1317G12                                                                                     See website for PCB layout drawing.



25A Vertical PCB Contacts Tin Plated

For mating with wire contacts only. Suitable for vertical applications up to 25A per pole,
tin plating enhances solderability.

                                                                Dimensions

Mating                 Loose Piece                              -A-

Force ---------------- Part Numbers --------------- inches mm

Minimum Quantity .... 1,000            100         .......................                                                        [ 3.1 ]

Low                1377G3-BK        1377G3         2.22 56.40                                                                     0.12                                           A
High               1317G3-BK        1317G3         2.22 56.40
Low                1377G4-BK        1377G4         1.76 44.70                                                                     Housing end
High               1317G4-BK        1317G4         1.76 44.70
Low                1377G13-BK       1377G13        1.17 29.70                                                                                                                       [ 36.5 ]
High               1317G13-BK       1317G13        1.17 29.70                                                                                                                        1.44
                                                                                                                                                                                        [ 28.6 ]
45A Right Angle and Vertical PCB Contacts Tin Plated                                                                                                                    [ 5.8 ]           1.13
                                                                                                                                                                        0.23
Suitable for right angle or vertical applications up to 45A per pole. Tin plating                                    Vertical                                                                     [ 16.3 ]
enhances solderability. Right angle contacts cannot be mixed with 25A PCB                                                                                                                          0.64
contacts. For mating with wire contacts only.

                                           Loose Piece                                    [ 29.7 ]                   [ 5.1 ]                                                                      PP15/45 Housings
                                                                                           1.17                      0.20                                                                         (1327 Series)
Description                  ----------- Part Numbers -----------                          REF
                                                                                                                                                                                            Right Angle Contact
Minimum Quantity ............. 1,000            100 ....................                   [ 7.9 ]                                                                                          Horizontal (bottom)
                                                                                            0.31                                                                                            Cat.No. 1336G1
Vertical                     3-5911P1           1335G1                                      TYP                                   [ 7.9 ]                               Right Angle Contact
Right Angle Bottom Row       3-5912P1           1336G1                                                                            0.31                                  Horizontal (top), Cat.No. 1337G1
Right Angle Top Row          3-5913P1           1337G1                                                                            TYP

                                                                                                  Use mounting staples with right angle contacts (see accessories).

All Data Subject To Change Without Notice                                                                                                                               www.andersonpower.com - 21 -
                          45A Premate Ground PCB Contacts

                          Right angle contacts are suitable for power or ground. Use to mate with 45A                      [ 45.3 ]                      [ 7.9 ]
                                                                                                                            1.78 [ 41.2 ]              0.31 TYP
                          ground wire contacts. Tin plated contacts are rated up to 1,500 mating cycles.         [ 14.7 ]            1.62
                                                                                                                 0.578                                   [ 8.4 ]
                          C an be u sed wit h other 45A PCB connectors in the bottom row.                                                              0.33 TYP

                                               Mating                        Loose Piece                                         [ 5.6 ]                 Pre-mate wire
                                                                                                                                  0.22           [ 7.9 ] connector
                                               Force ------- Part Numbers -------                                [ 3.6 ]                         0.31
                                                                                                                 0.14          [ 28.1 ]
                          Minimum Quantity ...................  1000         100 ....                                           1.11                     Mated Pair

                          PCB, Bottom Row Low                   3-5952P1 1836G1

                          | PP15-45 ULTRASONICALLY BONDED ASSEMBLIES |

SECTION 2                 Assemblies feature housings that are ultrasonically welded to create a one piece connector unit using an APP special process. After welding,
                          retaining pins are no longer required to secure the stacked housings to each other. This allows Powerpole 15-45 connectors to be used as a
   Powerpole PP15 to 45  durable one piece connector header. Contact customer service for configurations not shown below.

                          Single Row 1x2 Assemblies

                                                                                               Housings with     Housings with

                                                                                               45A Vertical      45A Right Angle                 Color & Type

                          Circuit Description                                Housings Only     PCB Contacts      PCB Contacts                    Position Matrix

                          Minimum Quantity ................................  500                      500        500              .....             1                   2

                          DC 2 Wire Standard Housings                        ASMPP30-1X2-RK    ASMPV45-1X2-RK    ASMPR45-1X2-RK                  RED / STD BLK / STD

                          DC 2 Wire Reverse Standard Housings ASMPP30-1X2-KR                   ASMPV45-1X2-KR    ASMPR45-1X2-KR                  BLK / STD RED / STD

                          DC 2 Wire Finger Proof                             ASMFP30-1X2-RK    ASMFV45-1X2-RK    ASMFR45-1X2-RK                  RED / FP BLK / FP

                          DC 2 Wire Finger Proof Reverse                     ASMFP30-1X2-KR    ASMFV45-1X2-KR    ASMFR45-1X2-KR                  BLK / FP RED / FP

                          

                          Single Row 1x3 Assemblies

                                                                                               Housings with     Housings with

                                                                                               45A Vertical      45A Right Angle                       Color & Type

                          Circuit Description                                Housings Only     PCB Contacts      PCB Contacts                          Position Matrix

                          Minimum Quantity ................................  500                      500                 500             .....  1                      2             3

                          DC 2 Wire Finger Proof with Ground                 ASMFP30-1X3-KER          N/A        ASMFR45-1X3-KER BLK / FP GRN / GND RED / FP

                          AC Single Phase Finger Proof                       ASMFP30-1X3-KEW ASMFV45-1X3-KEW ASMFR45-1X3-KEW BLK / FP GRN / GND WHT / FP

                          Two Row 2x1 Assemblies

                                                                                               Housings with     Housings with

                                                                                               45A Vertical      45A Right Angle                 Color & Type

                          Circuit Description                                Housings Only     PCB Contacts      PCB Contacts                    Position Matrix

                          Minimum Quantity ................................  500                      500                 500             ....   1                2

                          DC 2 Wire Finger Proof                             ASMFP30-2X1-KR    ASMFV45-2X1-KR    ASMFR45-2X1-KR                  BLK / FP RED / FP

                          DC 2 Wire Finger Proof Mate                        ASMFP30-2X1-RK    ASMFV45-2X1-RK    ASMFR45-2X1-RK                  RED / FP BLK / FP

                          

                          Two Row 2x2 Assemblies

                                                                                               Housings with     Housings with
                                                                                               45A Vertical
                                                                                               PCB Contacts      45A Right Angle                                        Color & Type

                          Circuit Description                                Housings Only               500     PCB Contacts                                     Position Matrix
                                                                                                         N/A
                          Minimum Quantity ................................  500               ASMFV45-2X2-WEKR           500             .....  1     2                   3                   4
                                                                                                                                                                                         GRN / GND
                          AC 3 Phase, 3 Wire Finger Proof                    ASMFP30-2X2-KRWE                             N/A                    BLK / FP RED / FP WHT / FP              RED / FP

                          AC 3 Phase, 3 Wire Finger Proof Mate ASMFP30-2X2-WEKR                                  ASMFR45-2X2-WEKR WHT / FP GRN / GND BLK / FP

                             12                                              1 23                                       1                                 12
                                                                                                                        2                                 34
                          Single Row 1x2 Assembly                            Single Row 1x3 Assembly
                                                                                                                 Two Row 2x1 Assembly                  Two Row 2x2 Assembly

                          Type                                  Hood Up

                          STD = Standard Housing
                          FP = Finger Proof Housing
                          GND = Ground Housing

- 22 - www.andersonpower.com                                                                                                                           All Data Subject To Change Without Notice
Powerpole Pak Connectors                                                           Powerpole Pak connector shells enclose stacked
- PP15 to PP45                                                                      groupings of PP15-45 sized housings in a durable black
                                                                                    shell for a finished connector appearance and additional
                        Plug shell                                                  features. Inline, panel mount, and blindmate configurations
                        with latch                                                  are available. Plug shells offer the option of integral latches
                                                                                    and strain relief to help secure your connection.
Snap-in
                                                                                     Package Groupings of PP15-45 Connectors
                                                  Blindmate
                                                                                      Provides a finished appearance while protecting the individual
             T-Pak            Plug shell                                              connectors with an outer shell                                                                       SECTION 2
                              without latch
                                                                                     Inline, Panel Mount, "T" or Blindmate Configurations                                               Powerpole Pak

                                                                                      Allows one connection system to meet multiple needs

                                                                                     Optional Latching and Strain Relief

                                                                                      Secures your connection and wires

For environmentally sealed connector shells to hold Powerpole
15-180 connectors, see APP's SPEC Pak product series on our
website, www.andersonpower.com

| Powerpole Pak ORDERING INFORMATION |                                                         Powerpole housings and contacts are sold separately.

                                                                                                See page 20 for ordering information.

Plug Shell without Latch

Can mate inline with other plug shells with or without latches, or mate to a panel

mount receptacle. For use with Powerpole wire connectors only. Cable Clamp                                                                                     [ 53.09 ]
                                                                                                                                                                  2.09
and Hardware Pak or Retaining Pins must be ordered separately.                                                                                 [ 21.59 ]
                                                                                                                                                 0.85
                                                             Dimensions

                                                                -A-

Description         -------------- Part Numbers -------------- inches mm                                                                                                              A

Minimum Quantity ... 1,000                 500    25 .............................                                                  [ 49.28 ]                   Retaining Pin
                                                                                                                                      1.94                        Top View
Black, 2-4 Poles 1461G1-BK                 -      1461G1 1.24 31.50
                                                                                                                                    Side View
Black, 5-6 Poles        -           1461G2-BK 1461G2 1.56 39.62

Black, 7-8 Poles        -           1461G3-BK 1461G3 1.87 47.50

                                                                                                             NOTE: Retaining pins are used to secure and position
                                                                                                             Powerpoles in one of three positions in plug shells.

Plug Shell with Latch                                                                                        Max wire O.D. for 2-4 pole plug shells is 0.60 inches [15.2mm].
                                                                                                             For all other plug shells is 0.63 inches [ 16.0 mm].

Can mate inline with other plug shells without latches, or mate to a panel mount receptacle. For use

with Powerpole wire connectors only. Cable Clamp and Hardware Pak or Retaining Pins must

be ordered seperately.                                                                                                                         Side View

                                                                                    Dimensions

- B -                                                                          -C-                   -D-                           [ 21.59 ]
                                                                          inches mm             inches mm                             0.85
Description         ------------- Part Numbers -------------- inches mm

Minimum Quantity ..... 1,000               500 25 ................................................................................                        B

Black, 2-4 Poles 1460G1-BK                 - 1460G1 1.94 49.28 2.25 57.15 1.24 31.50

Black, 5-6 Poles        -           1460G2-BK 1460G2 1.94       49.28 2.25          57.15 1.56        39.62                                    Top View
                                    1460G3-BK 1460G3 1.94       49.28 2.25          57.15 1.87        47.50                                                  C
Black, 7-8 Poles        -           1460G4-BK 1460G4 2.51       63.75 2.82          71.63 1.84        46.74

Black, 9-10 Poles       -

                                                                                                                                                                       D
                                                                                                                                               Retaining Pin

All Data Subject To Change Without Notice                                                                                                      www.andersonpower.com - 23 -
                   Snap-in Receptacle Shell

                   Mate to plug shells without latches, or mate to another panel mount receptacle to create a bulkhead to

                   bulkhead connection. For use with Powerpole wire or PCB connectors. Order the number of retaining pins for

                   each receptacle as shown below separately.                         Number of           Dimensions  Knock Out Size                                [ 27.94 ]  [ 1.78 ]  [ 19.56 ]
                                                                                      Retaining Pins           -E-       - Width -                                    1.10      0.07       0.77
                                                                                      to Order
                                                                                                          inches mm   inches mm

                  

                   Description        ---------------- Part Numbers ----------------

                   Minimum Quantity ... 1,000            500                    25 ...............................................................................             E

                   Black, 2-4 Poles 1470G1-BK            -           1470G1 1                             1.50 38.10 1.25 31.75

                   Black, 5-6 Poles        -           1470G2-BK 1470G2 2                                 1.88 47.75 1.62 41.15                                                          Retaining Pin
                                                       1470G3-BK 1470G3 3                                 2.13 54.10 1.88 47.75
                   Black, 7-8 Poles        -

                   Black, 9-10 Poles       -           1470G4-BK 1470G4 4                                 2.44 61.98 2.19 55.63

                   * Height = [25.4 mm] 1.0 in.                                                                            NOTE: Retaining pins are used to secure and position

                                                                                                                           Powerpoles in one of two positions in receptacle shells.

SECTION 2          Cable Clamp & Hardware Pak                                                                                                                                            Retaining Pin

   Powerpole Pak  Includes cable clamp, 2 screws, and required amount of retaining pins for each configuration.

                                  Screw Head Cable                                                                                                Cable Clamp
                                                                                                                                                  With Screws
                   Description Type                Type           ------------ Part Numbers ------------
                                                                                                                      Plug Shell Without Latch Shown
                   Minimum Quantity .................................... 1,000        500  25 ...
                                                                                                                      Shell, housing and contacts
                   2-4 Poles      Straight Slot Bundled 115G1-BK                      -    115G1                      are sold separately.

                   5-6 Poles      Straight Slot Bundled 115G2-BK                      -    115G2

                   7-8 Poles      Straight Slot Bundled 115G3-BK                      -    115G3

                   9-10 Poles Straight Slot Bundled               -             115G4-BK 115G4

                   2-4 Poles      Philips          Bundled 115G7-BK                   -    115G7

                   5-6 Poles      Philips          Bundled 115G8-BK                   -    115G8

                   Flexible Conduit Clamp & Hardware Pak                                                                                                                                 Retaining Pin

                   Includes cable clamp, 2 screws, and need amount of retaining pins for each configuration.

                   Description        Part Number

                   Minimum Quantity ...... 100 ......                                                                                       Conduit Clamp
                                                                                                                                            With Screws
                   2-4 Poles               110G10
                                                                                                                      Plug Shell With Latch Shown
                                                                                                                      Shell, housing and contacts
                                                                                                                      are sold separately.

                   Retaining Pin for Snap-in Receptacle

                   Order the number of retaining pins for each receptacle shown in the Snap-in Receptacle
                   Shell ordering information. Pins are also required for the plug side when the Cable Clamp &
                   Hardware Pak is not ordered.

                   Description        ------ Part Number -------

                   Minimum Quantity ...... 1,000       100 ....

                   Retaining Pin           110G9-BK 110G9                                                                  Shell and housing are sold separately.

- 24 - www.andersonpower.com                                                                                                                                                   All Data Subject To Change Without Notice
Blindmate Pak Connector                                                                                                  [ 88.6 ]   [ 50.8 ]  [ 36.7 ]  [ 58.93 ]                 [ 24.38 ]
                                                                                                                 [ 76.4 ] 3.49       2.00      1.45      2.320                     0.960
Ideal for panel to panel, bulkhead to bulkhead, or rack mount applications that require the
power connector to compensate for up to 0.45 in. [11.43 mm] of misalignment in either axis.                       3.01
Eight positions can be filled with Powerpole 10-45 connectors. The receptacle side can be
used with wire or PCB contacts. Hardware bag includes retaining pins.

Description                                           ---------- Part Numbers ----------

Minimum Quantity .................................................... 50  25 ..........        [ 5.0 ]           [ 38.6 ]                     [ 3.05 ]  [47.24]                   [ 13.46 ]
                                                                                              0.20 4             1.52                        0.120     1.860                     0.530
2x4 Blindmate Plug Shell, Hardware & Pins                        -        BMPP10-45P

2x4 Blindmate Receptacle Shell, Hardware & Pins                  -        BMPP10-45R

2x4 Blindmate Plug Shell                              BMHSG-P             -                                      Plug Outline                           Receptacle Outline

2x4 Blindmate Receptacle Shell                        BMHSG-R             -

Hardware Bag Plug Side                                           -        110G50                                                                        [ 29.14 ]
                                                                                                                                                         1.147
Hardware Bag Receptacle Side                                     -        110G51                     [ 30.2 ]
                                                                                                      1.19

                                                                                                                            [21.5]            [ 36.7 ]                            [ 0.64 ]     SECTION 2
                                                                                                                            0.85               1.45                               0.025
                                                                                                                                                                                             Powerpole Pak
                                                                                                                 [4.4]                                        [ 0.64 ]
                                                                                                                 0.17                                          0.025

See APP's innovative MARC Connector that offers straight-on or rotational blindmate capability.
MARC holds 6 PP15/45 power contacts and 2 PP15/45 premate ground contacts in a high temperature
housing. Visit our website, www.andersonpower.com to learn more.

"T" Pak 2 Way Splitter

The Powerpole "T" Pak connector is a 2 way electrical splitter that splits electrical current from
one incoming circuit into two outgoing circuits. The standard configuration is pre-wired for AC
3 phase, 3 wire plus ground configurations. The "T" Pak can also be used for AC single phase
plus ground or DC 2 wire plus ground applications by not using either the red or white power
positions. "T" Pak is pre-wired from the factory allowing plug and play field installation
of modular office and industrial equipment. UL recognition up to 20 amps and 600 volts is
achieved when mating Powerpole Pak plugs are used with #12 AWG wire.

For OEM manufacturing scale applications, the "T" Pak can be loaded with custom                                                                                         [ 86.2 ]
                                                                                                                                                                         3.39
configurations of any of APP's finger proof, standard, or ground housings and contacts                          [ 102.2 ]
                                                                                                                   4.03
i n the  PP15-45 series. Contact APP sales or customer service for additional information.
                                                                                                                  [ 43.2 ]
Description                                    - Part Numbers -                                                     1.70                                                [ 85.8 ]
                                                                                                                                                                         3.38
Minimum Quantity ............................  80 ........

Assembled "T" Pak                              20-01

Mating Plug Shell with Latch 2x2               26-01                                                                                                    [ 53 ]
                                                                                                                                                        2.09
Mating Plug Shell without Latch 2x2            27-01

Standard configuration for each side of the T includes (1) each Red, Black, and White Standard                                                [ 51.1 ]
PP 15-45 Housings & 261G2-LPBK contacts with (1) 45A Green Premate Ground Housing and                                                          2.01
1830G1-LPBK contact.

Mating plug shells include (1) each Red, Black, and White Standard PP 15-45 Housings &
(3) 261G2-LPBK contacts with (1) 45A Green Premate Ground Housing and 1830G1-LPBK
contact. Cable clamp & hardware pak also included.

                                       A

                                         B                                                         27 - 01                                               26 - 01
All Data Subject To Change Without Notice                                                                                                                Mates With A & C
                                                                                                   Mates With B
                                                                          C                                                                   www.andersonpower.com - 25 -
                          | PP15-45 & POWERPOLE PAK SPECIFICATIONS |

                          Electrical                                                       Mechanical

                          Current Rating Amperes                         UL 1977 CSA/TUV  Wire Size Range                                 AWG                    mm
                                                                                                                                                                  0.5 to 6.0
                          Singlepole Wire to Wire (10 AWG)                55         40                                                    20 to 10
                                                                                                                                                                  mm
                          Singlepole Ground Wire to Wire or PCB (10 AWG) 45          35                                                                           4.450

                          3x3 Block Wire to Wire (10 AWG)                 40         27    Max. Wire Insulation Diameter                   in.                    C
                                                                                                                                                                  -20 to 105
                          Singlepole 25A PCB to Wire (12 AWG)             25         -                                                     0.175
                                                                                                                                                                  Tin (Sn)
                          2x3 Block 25A PCB to Wire (12 AWG)              25         22 *                                                                         1,500
                                                                                                                                                                  1,500
                          Singlepole 45A PCB to Wire (10 AWG)             45         40 *  Operating Temperature                          F
                                                                                                                                                                  N
                          2x3 Block 45A PCB to Wire (10 AWG)              45         25 *  Powerpole Housings & Powerpole Pak Shells -4 to 221                13
                                                                                                                                                                  22
                                                                                                                                                                  9

                          Voltage Rating AC/DC                                             Mating Cycles No Load by Plating                Silver (Ag)            N
                                                                                                                                                                  90
                          UL 1977                                         600              PCB to Wire                                     -
                                                                                                                                                                  N
                                                                                           Wire to Wire                                    10,000                 667

SECTION 2                 PCB Connector Recommended Voltage                                                                                                      (2.3-3.8)

   Powerpole PP15 to 45  per IEC 60950-1 Table 2L Pollution Degree2                       Avg. Mating / Unmating Force                    Lbf.                   mm
                                                                                                                                                                  5.1
                          25A Contacts Adjacent Poles                     495              Low Force Wire, High Force PCB, & Ground        3                      1.7

                          25A Contacts Separated by Spacer                1,000            High Force Wire                                 5

                          45A Contacts Adjacent Poles                     160              Low Force PCB                                   2

                          45A Contacts Separated by Spacer                970              

                                                                                           Min. Contact / Spring Retention Force           Lbf.

                          Dielectric Withstanding Voltage                                                                                  20

                          Volts AC                                        2,200            

                                                                                           Powerpole Pak Latch Avg. Defeat Force          Lbf.

                          Avg. Mated Contact Resistance Milliohms                                                                         150

                          15A Wire Contact with 5/8" of #16 AWG           0.875            

                          30A Wire Contact with 5/8" of #12 AWG           0.600            PCB Specifications

                          45A Wire Contact with 5/8" of #10 AWG           0.525            Mounting Style                                  Plated Through Hole

                          45A PCB Contact to Contact                      0.500            PCB Thickness- in. [mm]                         0.090 - 0.150

                          25A PCB Contact to Contact                      0.600            25A PCB Recommended Traces                      #12 AWG Cross Section

                                                                                           45A PCB Recommended Traces                      #10 AWG Cross Section

                          UL Hot Plug Current Rating Amperes                              

                          250 cycles at 72V DC                            45A              Min. Creepage / Clearance Distance PCB          in.

                          250 cycles at 120V DC                           30A              25A Creepage & Clearance Adjacent Poles         0.201

                                                                                           45A Creepage & Clearance Adjacent Poles         0.067

                          UL Ground Short Time Current Test - 45A Premate Ground

                          750 Amps, #10 AWG Wire                          4 Seconds        Protection

                          470 Amps, #12 AWG Wire                          4 Seconds        Touch Safety with Finger Proof Housings & Wire

                                                                                           Contacts or PCB Mating Interface

                          Materials                                                        UL1977 Sec. 10.2 Pass

                          Housing                                                          IEC 60950        Pass
                           Plastic Resin
                           Contact Retention Spring        Polycarbonate                   IEC 60529        IP20
                                                           Stainless Steel

                                                                                           Touch Safety Standard Housings

                          Housing Flammability Rating                                      IEC 60529        IP10

                          UL94                             V-0

                          Contact                          Copper Alloy                    * No TUV Recognition
                           Base                            Tin or Silver                   1 Based on: 105C rated or better cable of the largest size, Properly calibrated APP
                           Plating
                                                                                            recommended tooling, and a 25C ambient temperature. UL rating not to exceed the
                          Contact Termination Methods      Wire Contacts                    maximum operating temperature. CSA rating below a 30C temperature rise.
                           Crimp                          Wire and PCB Contacts           2 Limited by the thermal properties of the connector plastic housing.
                           Hand Solder                     PCB Contacts                    3 Use APP recommended tooling only. Alternate tools may adversely affect the
                           Solder Dip                      PCB Contacts                      performance of our connectors along with UL and CSA recognition.
                           Wave Solder

- 26 - www.andersonpower.com                                                                                                                    All Data Subject To Change Without Notice
| PP15-45 TEMPERATURE CHARTS |

                                      PP15-45 Singlepole                                                     PP15-45 Multipole                                                        PP25 PCB
                          Temperature Rise at Constant Current                                  Temperature Rise at Constant Current                                Temperature Rise at Constant Current
                  60                                                                   60                                                                   60

                  50                                                                   50                                                                   50

Temperature (C)  40                                                 Temperature (C)  40                                                 Temperature (C)  40

                  30                                                                   30                                                                   30

                  20                                                                   20                                                                   20

                  10                                                                   10                                                                   10

                      0                                                                0                                                                    0
                                                                                                                                                               0 5 10 15 20 25 30 35 40
                         0  10 20 30 40 50 60                                               0  10              20      30             40                                                                     SECTION 2

                                        Amperes Applied                                                Amperes Applied                                                         Amperes Applied             Powerpole PP15 to 45

                            10 AWG      12 AWG            14 AWG                               10 AWG          12 AWG       14 AWG                                 Singlepole  2-Pole           Multipole
                                                                                                                            20 AWG
                            16 AWG      18 AWG            20 AWG                               16 AWG          18 AWG

                                         PP15-45 Singlepole                                                   PP15-45 Multipole                                                         PP25 PCB
                               Derating vs. Ambient Temperature                                    Derating vs. Ambient Temperature
                  125                                                                  125                                                                              Derating vs. Ambient Temperature
                                                                                                                                                            125

Temperature (C)  100                                                Temperature (C)  100                                                Temperature (C)  100

                  75                                                                   75                                                                   75

                  50                                                                   50                                                                   50

                  25        10 20 30 40 50                60 70                        25      10          20      30       40        50                    25     5 10 15 20 25 30 35 40
                       0                                                                   0                                                                    0
                                                          14 AWG
                                        Amperes Applied   20 AWG                                       Amperes Applied                                                         Amperes Applied

                            10 AWG      12 AWG                                                 10 AWG          12 AWG       14 AWG                                 Singlepole  2-Pole           Multipole
                            16 AWG      18 AWG                                                                              20 AWG
                                                                                               16 AWG          18 AWG

                                            PP45 PCB                                                              PP45 PCB
                         Temperature Rise at Constant Current                                     Derating vs. Ambient Temperature
                  60                                                                   125

                  50

Temperature (C)                                                     Temperature (C)  100

                  40

                  30                                                                   75

                  20

                                                                                       50

                  10

                  0                                       50 60                        25      10 20 30 40 50               60 70
                     0 10 20 30 40                        Multipole                        0                                Multipole
                                         Amperes Applied
                                                                                                           Amperes Applied

                            Singlepole  2-Pole                                                 Singlepole      2-Pole

NOTE: Temperature rise charts are based on a 25C ambient temperature. PP25 PCB charts based on 0.002 in foil on board side, mated to #12 AWG conductor on
wire side. PP45 PCB charts based on #10 AWG equivalent copper foil on board side, mated to #10 AWG conductor on wire side.

All Data Subject To Change Without Notice                                                                                                                          www.andersonpower.com - 27 -
                          | Powerpole 15-45 Accessories |

                          Mounting Wing

                          Secure dovetailed Powerpole 15-45 series housings by passing fasteners through the wings
                          in either a horizontal or vertical orientation. Useful for sheet metal panels, printed circuit boards,

                          and many other mounting surfaces. Fasteners not included.

                          Description  ------- Part Numbers -------                                                                                                                                       Mounting Wings

                          Minimum Quantity ... 2,500                100 ....                                                                          [ 4.6 ]
                                                                                                                                                      0.180
                          Red          1399G9-BK 1399G9

                          Blue         1399G8-BK 1399G8                                                                                                                   [ 7.9 ]
                                                                                                                                                                          0.312

                                                                                                                                                      [ 16.6 ]
                                                                                                                                                      0.655

SECTION 2                 Spacer

   Powerpole PP15 to 45  Used to separate housings under high power to minimize derating. They are
                          recommended for squaring off a block of Powerpole 15-45 housings for use in connector shells
                          and mounting clamps. Use a combination of long and short spacers opposite eachother in a
                          mated block to add keying features or use two short spacers to avoid interference. Spacers with
                          holes can also be used to fasten the blocked housings to a surface with a fastener.

                          Description  ------ Part Numbers -------

                          Minimum Quantity ..... 2,500              100 .....

                          Red, Short w/ Hole 1399G1-BK 1399G1                                                                                                                                                     [ 7.9 ]
                                                                                                                                                                                                                  0.312
                          Red, Long    1399G2-BK 1399G2                                                     [ 7.9 ]                                                                [ 7.9 ]
                                                                                                            0.312                                                                  0.312                  Long
                          Red, Short   1399G6-BK 1399G6
                                                                                    [ 16.6 ]
                          Black, Long  1399G10-BK 1399G10                           0.655                                                                       [ 16.6 ]                      [ 24.6 ]
                                                                                                                                                                0.655                         0.968
                          Blue, Short  1399G13-BK 1399G13                                  Short with Hole

                          White, Short w/ Hole 1399G14-BK 1399G14                                                                                                         Short without Hole

                          White, Long  1399G17-BK 1399G17

                          Retaining Pins

                          Keep stacked Powerpole 15-45 series housings from separating. Retaining pins are inserted in

                          the circular opening between two housings stacked side by side.

                                                                                    Dimensions

                                                                               -A-                        -B-

                          Description ----- Part Numbers ----- inches  mm inches mm

                          Minimum Quantity ... 1,000                100 ............................................................................

                          1 Block High H1507P38 110G16 0.0942.390 0.250 6.350

                          2 Block High 111812P5 110G17 0.099 / 0.1060.251 / 2.69 0.440 11.180

                                                                                                                                                                                   B
                                                                                                                                                                                                       A

                          Mounting Clamp

                          Mounting clamps can be used for fastening a block of Powerpole 15-45 series
                          housings to a panel. Connector blocks must be a complete square for the clamps
                          to work properly. Fastening hardware not included.

                          Description  -- Part Numbers --

                          Minimum Quantity ... 100 sets of 2 .....

                          2 or 4 Pole  1462G1

                          3 or 6 Pole  1462G2

                          4 or 8 Pole  1462G3                                                                                                                   2 or 4 Pole        3 or 6 Pole            4 or 8 Pole

- 28 - www.andersonpower.com                                                                                                                                                       All Data Subject To Change Without Notice
PCB Mounting Staples

PCB staples are soldered into place to secure Powerpole 15-45 series housings
in a horizontal configuration to the board. Reduce strain on soldering joints during
mating and unmating.

                                                Dimensions

Part                                       -A-              -B-

Numbers H x W Length inches mm                        inches mm

Minimum Quantity 100 ................................................................................

114555P1 1 x 1 Short   0.47                     12.0  0.28       7.0                                   A
                                                                                                                         B
114555P2 1 x 2 Short   0.47                     12.0  0.57       14.5

114555P11 1 x 2 Long   0.67                     17.0  0.57       14.5

114555P3 1 x 3 Short   0.47                     12.0  0.89       22.5

114555P7 1 x 4 Short   0.47                     12.0  1.20       30.5

114555P12 1 x 4 Long   0.67                     17.0  1.20       30.5                                                                                       SECTION 2

114555P8 1 x 6 Short   0.47                     12.0  1.83       46.5                                                                                     Powerpole PP15 to 45

114555P13 2 x 2 Long   0.91                     23.0  1.83       46.5

114555P10 2 x 1 Short  0.79                     20.0  0.28       7.0

114555P6 2 x 2 Short   0.79                     20.0  0.57       14.5

114555P9 5 x 2 Long    0.91                     23.0  0.57       14.5

114555P14 2 x 5 Long   0.91                     23.0  1.52       38.5

114555P4 3 x 2 Short   1.10                     28.0  0.57       14.5



Retention Clip

Retention clips prevent Powerpole 15-45 blocks from unintended disconnects.

They feature a tab for easy insertion and removal.

Description    -- Part Number --

Minimum Quantity ........ 100 .........

1 Block High   110G68



Block Lok

Block locks secure mated Powerpole 15-45 series housings together. For use in

h igh vibration or sh ock applications where connectors are unmated infrequently.

Description    - Part Numbers -

Minimum Quantity .......... 100 .........                                                                             2 Pole        4 Pole
                                                                                                       Shown without Powerpoles  Shown with Powerpoles
2 Pole, Black  110G21

4 Pole, Black  110G12



Splash Boot

Splash boots protect a 2x2 block of any combination of Powerpole 15-45 series
housings and feature snip off sealed ends for flexibility in wire O.D. Designed for
through panel or inline applications. Not a hermetic seal.

Description    - Part Numbers -

Minimum Quantity ........ 25 ...........

Female, Black  1441G1

Male, Black    1442G1

For environmentally sealed connector shells to hold Powerpole
15-180 connectors, see APP's SPEC Pak product series on our
website, www.andersonpower.com

All Data Subject To Change Without Notice                                                                                         www.andersonpower.com - 29 -
                    Powerpole Connectors                                                  PP75 series Powerpole housings can be used for wire-to-wire,
                    - PP75: up to 120 Amps                                                 wire-to-board, and wire-to-busbar applications. Wire sizes
                                                                                           from #16 AWG (1.3 mm) to #6 (13.3 mm) offer power
                                    PP75 with                                              capabilities up to 120 amps per pole. Locking housings offer
                                    Mounting Wings                                         the capability to secure Powerpole housings to each other
                                                                                           and to mounting pads. Housings made from chemical
SECTION 2                                                                                  resistant (CR) resin withstand industrial solvents better than
                                                                                           standard housings.
   Powerpole PP75
                                                                                           Large Wire Range Accommodates up to #6 (10mm) Wire
                                                                                             Reducing bushings allow as small as #16 (1.5 mm) wire to be used

                                                                                           Wire, PCB, and Busbar Contacts
                                                                                             Allows one connection system to meet multiple needs

                                                                                           Mini-Powerclaw PCB Contacts Minimize PCB Footprint

                                                                                             Removes the PP75 housing from the board side

                    | PP75 ORDERING INFORMATION |

                    PP75 Standard Housings

                    The second smallest Powerpole housing can be used with wire contacts

                    for up to 6 AWG [10mm] as well as PCB and busbar contacts.

                    Description  ------- Part Numbers --------

                    Minimum Quantity ... 1,000     100 ......

                    Red          5916G7-BK 5916G7

                    Green        5916G6-BK 5916G6                                          [ 15.9 ]
                                                                                            0.62
                    Black        5916G4-BK 5916G4                                                                   [ 47.9 ]
                                                                                                                     1.88
                    White        5916G5-BK 5916G5

                    Blue         5916-BK        5916                                                      [ 15.9 ]                               [ 17.0 ]
                                                                                                           0.62                                   0.67
                    Yellow       5916G15-BK 5916G15
                                                                                           Front View
                    Orange       5916G14-BK 5916G14                                                                                    [ 81.3 ]
                                                                                                                                        3.20
                    Gray         5916G16-BK 5916G16
                                                                                                                    Mated Length

                    

                    PP75 Chemical Resistant (CR) Housings

                    Has the same form and dimensions of the standard
                    PP75 housing in a chemical resistant PBT/ PC blend
                    housing. Suitable for use to -40C.

                    Description  - Part Numbers -                                                                   Material ID                  V0 = Standard

                    Minimum Quantity ... 1,000 .......                                                              Located Here P = Chemical Resistant

                    Red          P5916G7-BK

                    Black        P5916G4-BK

                    White        P5916G5-BK

                    Blue         P5916-BK

                    

- 30 - www.andersonpower.com                                                                                                     All Data Subject To Change Without Notice
PP75 Locking Dovetail Housings

Offers dovetails for stacking housings that have a locking feature to prevent housings separating.

Can mate to standard and chemical resistant housings, but cannot be stacked with them.

Description            ---------- Part Numbers -----------

Minimum Quantity ....  1,000                100 .....

Red                    75LOKRED-BK 75LOKRED

Green                  75LOKGRN-BK 75LOKGRN

Black                  75LOKBLK-BK 75LOKBLK

White                  75LOKWHT-BK 75LOKWHT                                                                                                                          [ 47.9 ]
                                                                                                                                                                      1.88
Blue                   75LOKBLU-BK 75LOKBLU

Gray                   75LOKGRA-BK 75LOKGRA

PP75 Silver Plated Wire Contacts                                                                                                                                                                SECTION 2

Silver plated contacts offer the best electrical performance and durability up to 10,000 mating cycles.                                                                                       Powerpole PP75

                                                               Dimensions
                                                                      -A-
                       Mating              Loose Piece
                                                               inches mm
AWG            mm     Force               -- Part Numbers --  ........................
                                                               0.22 5.59
Minimum Quantity ........................ 1,000 100            0.22 5.59
                                                               0.19 4.83
6              13.3    Low                 1307-BK 1307        0.14 3.56
                                                               0.14 3.56
6              13.3    High                5900-BK 5900                                                  [ 11.4 ]                      [ 30.0 ]
                                                                                                          0.45                          1.18
8              8.4     High                5952-BK 5952
                                                                                                           A
12 to 10 3.3 to 5.3 Low                    5953-BK 5953
                                                                                                         [ 7.2 ]
12 to 10 3.3 to 5.3 High                   5915-BK 5915                                                   0.28

                                                                                                                                                                               [ 7.1 ]
                                                                                                                                                                               0.28
PP75 Tin Plated Reeled Wire Contacts
                                                                                                                                                                                    [ 17.1 ]
Reeled contacts are for use with the recommended high volume press and applicator tooling.                                                                                           0.68
Tin plating is rated for up to 1,500 mating cycles. Silver plated or low mating force contacts
may be available for high volume applications. Inquire with customer service.

                       Reeled                                  Dimensions

                       Mating Part                       -A-               -B-

AWG mm                Force Numbers inches mm inches mm

Minimum Quantity ....................... 2,000 ........................................................                                          A

8 to 6 8.4 to 13.3 High                    265G5 0.26 6.60 0.36 9.14

12 to 10 3.3 to 5.3 High                   265G6 0.17 4.32 0.29 7.37                                                         [ 32.2 ]  B
                                                                                                                              1.27


PP75 Silver Plated Busbar Contacts

Provide a quick disconnect input or output busbar connection. Busbar contacts are

for mating with wire contacts only. Part number 75BBS includes lock nuts. Locknuts                                           See Busbar contact drawing on
                                                                                                                             website for further detail.
m ust b e ordered separately for B01956P4.
                                                                                                                                                            [ 2.0 ]
                       Mating                                                                                                                               0.08
                                                                                                                                                   [ 69.1 ]
Type         Thread Force -------------------- Part Numbers --------------------                                                                     2.72

Minimum Quantity ................. 1,000    120                20          10 ...

Busbar #10-24 High B01956P4 B01956P4                           -       75BBS

Lock Nut #10-24 -              H1216P8      -                  110G54      -

55A Right Angle Standard Powerclaw PCB Contacts                                                                                                          Second housing
                                                                                                                                                         and contact in two
Standard Powerclaw contacts are for use inside a PP75 housing and                                                                                        pole version only.

provide a color coded right angle connection to the PCB.                                                                                         [ 32.8 ]
                                                                                                                                                  1.29
Description          --- Loose Piece Part Numbers --                    [ 5.2 ]                                              [ 17.0 ]
                                                                         0.20                                                 0.67
Minimum Quantity ..... 500                 100 ........
                                                                       [ 22.2 ]
Tin Plated           PC5930T-BK PC5930T                                 0.87

Silver Plated        PC5930S-BK PC5930S

                                           PP75 Housing                                                            [ 48.0 ]                      See PCB contact drawing on
                                                                                                                    1.89                         website for further detail.

                                                                                                         [ 66.0 ]
                                                                                                          2.60

            Standard Powerclaw Contact

All Data Subject To Change Without Notice                                                                                                        www.andersonpower.com - 31 -
                    55A Right Angle Mini Powerclaw PCB Contacts                                                                    [ 8.1 ]                                                      [ 12.19 ]
                                                                                                                                    0.32                                                         0.480
                    Right angle Mini Powerclaw contacts can be used on the PCB edge
                    without a PP75 housing on the PCB side. A self polarizing design only                                     [ 7.6 ]
                    allow PP75 wire housings to mate to PCB contacts one way.                                                 0.30

                                                       Loose Piece                                        [ 58.4 ]             [ 2.42 ]                     [ 24.6 ]
                                                                                                           2.30                 0.095                        0.97
                    Description                -------- Part Numbers --------                                       [ 15.6 ]
                                                                                                                     0.61          [ 6.10 ]
                    Minimum Quantity ... 1,000                  100 ......                                                          0.240

                    Tin Plated PC5934T-BK PC5934T                                                                                                                                                          [ 25.4 ]
                                                                                                                                                                                                            1.00
                    Silver Plated PC5934S-BK PC5934S                                                                                                                                  [ 17.5 ]
                                                                                                                                                                                       0.69                      [ 1.27 ]
                                                                                                                                                                                                                  0.050

                    55A Vertical Mini Powerclaw PCB Contacts                                                                                                                          [ 12.2 ]             [ 6.25 ]
                                                                                                                                                                                       0.48                0.246
                    Vertical Mini Powerclaw contacts save space by not
                    requiring a PP75 housing on the PCB side. The guide
                    housing is required for 2 pole applications to provide a
                    polarized connection. (See PP75 accessories).

                                                       Loose Piece                                                                                [ 24.3 ]
                                                                                                                                                   0.96
SECTION 2           Description                --------- Part Numbers -------

   Powerpole PP75  Minimum Quantity ... 1,500                  100 ......                                                                        [ 9.7 ] [2.32]
                                                                                                                                                  0.38 0.091
                    Tin Plated                 PC5933T-BK PC5933T                                                                                                                                           [ 1.27 ]
                                                                                                                                                                                                            0.050
                    Silver Plated              PC5933S-BK PC5933S
                                                                                                                                                                                                           [ 4.98 ]
                                                                                                                                                                                      [ 10.29 ]            0.196
                                                                                                                                                                                       0.405

                                                                                                                              See PCB contact drawing on website for further detail.

| PP75 TEMPERATURE CHARTS |

                                               PP75 Singlepole                                                        PP75 Multipole                                                                 Mini Powerclaw
                                                                                                          Derating vs. Ambient Temperature
                                      125    Derating vs. Ambient Temperature                        125                                                                                 Derating vs. Ambient Temperature
                                                                                                                                                                              125

                    Temperature (C)  100                                          Temperature (C)  100                                                    Temperature (C)  100

                                      75                                                             75                                                                       75

                                      50                                                             50                                                                       50

                                      25     20 40 60 80 100 120                                     25                                                                       25      10 20 30 40 50 60 70 80 90 100110
                                          0                                                              0 10 20 30 40 50 60 70 80 90 100                                          0                Amperes Applied

                                               Amperes Applied                                            Amperes Applied

                                               6 AWG    8 AWG                                             6 AWG      8 AWG                                                            Singlepole           2-Pole
                                               10 AWG  12 AWG                                             10 AWG    12 AWG

                                             PP75 Singlepole Loose Piece Contact                             PP75 Multipole Loose Piece Contact                                                     Mini Powerclaw
                                             Temperature Rise at Constant Current                                                                                                    Temperature Rise at Constant Current
                                      60                                                                    Temperature Rise at Constant Current                              60
                                                                                                     60

                                      50                                                             50                                                                       50

                    Temperature (C)  40                                           Temperature (C)  40                                                     Temperature (C)  40

                                      30                                                             30                                                                       30

                                      20                                                             20                                                                       20

                                      10                                                             10                                                                       10

                                      0                                                              0                                                                        0
                                         0 10 20 30 40 50 60 70 80 90 100 110 120                      0 10 20 30 40 50 60 70 80 90                                              0 10 20 30 40 50 60 70 80 90
                                                                                                                                                                                                    Amperes Applied
                                               Amperes Applied                                            Amperes Applied

                                               6 AWG    8 AWG                                             6 AWG      8 AWG                                                            Singlepole           2-Pole
                                               10 AWG  12 AWG                                             10 AWG    12 AWG

                    NOTE: Temperature rise charts are based on a 25C ambient temperature. Powerclaw charts are based on #8 AWG equivalent copper foil on board side, mated to
                    #6 AWG conductor on wire side.

- 32 - www.andersonpower.com                                                                                                                                                          All Data Subject To Change Without Notice
| PP75 SPECIFICATIONS |

Electrical                                                  Mechanical

Current Rating Amperes                    UL 1977 CSA      Wire Size Range                      AWG                     mm
Wire to Wire (6 AWG)
Wire to PCB (6-AWG)                       120    70                                             16 to 6                 1.3 to 13.3
Wire to Busbar (6 AWG)
                                           55     50        

                                           75               Max. Wire Insulation Diameter        in.                     mm

                                                                                                 0.437                   11.100

Voltage Rating AC/DC                                       

UL 1977                                    600              Operating Temperature               F                      C

                                                            Standard                             -4 to 221             -20 to 105

PCB Connector Recommended Voltage 3                         Chemical Resistant*                  -40 to 221             -40 to 105

per IEC 60950-1 Table 2L Pollution Degree 2                 *Chemical resistant material not available for PCB guide housings

Mini Vert. Contact Adjacent Poles          220              

Mini Horiz. Contact Adjacent Poles         200              Mating Cycles No Load by Plating     Silver (Ag)             Tin (Sn)

Standard Contact Adjacent Poles            635              Wire and PCB Contacts                10,000                  1,500                                        SECTION 2

                                                                                                                                                                    Powerpole PP75

Dielectric Withstanding Voltage                             Avg. Mating / Unmating Force         Lbf.                    N

Volts AC                                   2,200            Wire to Wire Low Force Contacts      5                       22

                                                            Wire to Wire High Force Contacts     7                       31

Avg. Mated Contact Resistance Milliohms                    Standard Powerclaw to Wire           7                       31

Wire Contact with 1 1/4" of #6 AWG 0.200                    Mini Powerclaw to Wire               4                       17

PCB Contact to Contact                     0.500            

                                                            PCB Specifications

UL Hot Plug Current Rating Amperes - 250 cycles at 120V DC  Mounting Style                       Plated Through Hole

Wire- wire                                 50A              Max PCB Thickness- in. [mm]          Standard: 0.15 [0.381]

PCB- wire (Vertical Mini Powerclaw) 40A                                                          Mini: 0.25 [0.635]

                                                            Recommended Traces                   #8 AWG Cross Section

Materials                                                   

Housing                                                     Min. Contact / Spring Retention Force Lbf.                   N
Standard Plastic Resin
Chem. Resistant Resin       Polycarbonate                  Wire Housing                         50                      222
Contact Retention Spring    Polycarbonate / PBT blend
                             Stainless Steel               

                                                            Min. Creepage / Clearance Distance PCB in.                   mm

                                                            Standard Powerclaw Adjacent Poles    0.260                   6.6

Housing Flammability Rating                                 Mini Vert. Powerclaw Adjacent Poles  0.087                   2.2

UL94                         V-0                            Mini Horz. Powerclaw Adjacent Poles  0.079                   2.0

Contact                                                     Protection
Base
Wire Plating                Copper Alloy                   Touch Safety with Wire Contacts
PCB Plating                 Silver
                             Sn or Ag over Ni               IEC 60529        IP10

Contact Termination Methods

Crimp4                       Wire Contacts

Hand Solder                  Wire and PCB Contacts

Solder Dip*                  PCB Contacts

Wave Solder*                 PCB Contacts

Wrench / Socket              Busbar Contacts

Based on: 105C rated or better cable of the largest size, Properly calibrated APP recommended tooling, and a 25C ambient temperature. UL rating not to exceed
the maximum operating temperature. CSA rating below a 30C temperature rise.
Limited by the thermal properties of the connector plastic housing.
Without use of spacers to increase creepage and clearance distances.
4 Use APP recommended tooling only. Alternate tools may adversely affect the performance of our connectors along with UL and CSA recognition.

All Data Subject To Change Without Notice                                                               www.andersonpower.com - 33 -
                    | Powerpole PP75 Accessories |

                    Strain Relief Grommets

                    Use for strain relief in the back side of a PP75 housing. Wire gauge given for reference

                    only, use grommet ID and wire OD to determine suitability in the end application.

                                                       Dimensions

                                                       -A-

                    Description           - Part Numbers - inches mm

                    Minimum Quantity ...     100       .......................

                    #6 AWG, Black            114411P2  0.35 8.89

                    #8 AWG, Black            114411P1  0.25 6.35                                                                           A

                    #10 - 12 AWG, Black 114411P3       0.17 4.32

SECTION 2           Mounting Wing for Standard or CR Housings

   Powerpole PP75  Mounting wings can be used to secure dovetailed Powerpole 75 series housings by
                    passing fasteners through the wings in either a horizontal or vertical orientation. Useful for
                    sheet metal panels, printed circuit boards, and many other mounting surfaces. Fasteners
                    not included.

                    Description           ------- Part Numbers -------                                                                             [ 27.4 ]                   [ 27.4 ]
                                                                                                                                                     1.08                       1.08
                    Minimum Quantity ... 1,000         100 ...
                                                                                                                                           [ 15.9 ]                    [ 15.9 ]
                    Blue, Round Hole 1399G20-BK 1399G20                                                                                     0.63                        0.63
                                                                                                                                              [ 15.9 ]                    [ 15.9 ]
                    Blue, Oval Hole       1399G7-BK 1399G7                                                                                      0.63                       0.63

                    Mounting Wing for Locking Housings

                    Mounting wings can be used to secure Powerpole 75 series housings with locking

                    dovetails by passing fasteners through the wings in either a horizontal or vertical orientation.

                    Useful for sheet metal panels, printed circuit boards, and many other mounting surfaces.

                    Fasteners not included.                                                                           [ 2.6 ]                                            [ 5.1 ]
                                                                                                                                                                        0.20
                    Description           --------------------- Part Numbers ---------------------                    R 0.10                                 [ 15.9 ]
                                                                                                                                [ 6.9 ]                                Round Hole
                    Minimum Quantity ...     1,000                      100                ...                                                                         - Mounting Wing Top
                                                                                                                      Oval Hole0.2 7 0.63
                    Blue, Oval Hole          75LOKWNGBLU-BK 75LOKWNGBLU                                                                    [ 01 .56.39 ]

                    Blue, Round Hole         75LOKWNGBLU-R-BK 75LOKWNGBLU-R                                           - Mounting Wing Top

                                                                                                                      Left Side View                                       [ 5.1 ]      [ 27.4 ]
                                                                                                                      - Both Versions                                     .20          1.08

                                                                                                                                                             Right Side View
                                                                                                                                                             - Both Versions

                    Surface Mount for Locking Housings                                                                         [ 2.8 ]     [ 15.7 ]
                                                                                                                               0.11         0.62
                    Use to secure Powerpole 75 series housings with locking dovetails to a flat surface.
                    Useful for sheet metal panels, printed circuit boards, and many other mounting surfaces.                               [ 7.9 ]                          [ 43.2 ]    [ 4.9 ]
                    Fasteners not included.                                                                                                0.31                              1.70       0.19

                    Description           ----------------- Part Numbers ----------------                             [ 3.6 ]                                          Side View
                                                                                                                      0.14 Top View
                    Minimum Quantity ...     1,000                      100 ...

                    Blue                  75LOKSMTBLU-BK 75LOKSMTBLU

                    

                    

- 34 - www.andersonpower.com                                                                                                                                 All Data Subject To Change Without Notice
Guide Housings for Vertical Mini Powerclaw Contacts

Prevents polarity being reversed when a two pole PP75 block is mated to

vertical mini Powerclaw contacts. Fastening hardware not included.



Description             ----------- Part Numbers ------------

Minimum Quantity ...    1,000                        100 ...                                                           PP75 Connector
                                                                                                                      Mini Vertical
Black Guide Housing PC-HSG-PP-BK PC-HSG-PP                                                                            Powerclaw Contact

                                                                                                                           Guide Housing
                                                                                                                                        PCB

Mounting Clamp                                                                                                                                                                     SECTION 2

Mounting clamps can be used for fastening a block of Powerpole 75 series                                                                                                        Powerpole PP75
housings to a panel. Connector blocks must be a complete square for the
clamps to work properly. Fastening hardware not included.

Description     -- Part Numbers --

Minimum Quantity ... 50 sets of 2 ...

2 or 4 Pole             1463G1                                                           Mounting Clamp

3 or 6 Pole             1463G2

                                                                                         Panel

                                                                                                                                                  2 Pole  3 Pole

Retaining Pins

Retaining pins are used to keep stacked Powerpole 75 series housings from separating.

Retaining pins are inserted in the circular opening between two housings stacked side by side.

Dimension B is +/- 0.015 in or 0.38 mm.

                                                                             Dimensions

                                                               - A -                     -B-

Description           ------ Part Numbers ------ inches                      mm          inches mm

Minimum Quantity ... 1,000      100 ................................................................................

1 Block High            111812P7 110G19 0.196 / 0.207 4.98 / 5.26 0.560 14.220

2 Block High            111812P6 110G18 0.196 / 0.207 4.98 / 5.26 1.000 25.400

PCB Mounting Staples                                                                                                                                      B
                                                                                                                                                                              A
Reduce strain on solder joints during mating and unmating. Staples bend over the underside

of the PCB board to lock the housings in place. Staples are an interference fit with housings.

---- Part Numbers ----  Number of                                                                          Staple
Minimum Quantity .....  Stacked Powerpoles                                                   Housings
PCSTAPLE-1              HxW
PCSTAPLE-2              100 .......................                                                   PCB
                        1x1
                        1x2                                                                                                                                    Fasten the staple by
                                                                                                                                                               bending the leads on the
                                                                                                                      Slide staple over housings and           bottom of the board.

Reducing Bushings                                                                                                     into the holes in the board.        ID
                                                                                                                                                          Wire Entrance
Use with contact part number 5900-BK or 1307-BK to allow a smaller wire to

be used with the connector. Electrical capability is derated with smaller wire.

                                                                                                    Dimensions

                                                                                         - ID -                       - Length -

Contact Barrel Size Wire Size            ------------------ Part Numbers ------------ inches mm Inches mm

Minimum Quantity .................................................... 3,000   1,000 100 ........................................................
                                                                             5912-BK 5912 0.18 4.57 0.45 11.43
#6 AWG [13.3 mm] #8 AWG [8.4 mm]                             -                                                                                  Length

#6 AWG [13.3 mm] #12- 10 AWG [3.3- 5.3 mm] 5910-BK                             -  5910 0.14 3.56 0.47 11.94

#6 AWG [13.3 mm] #16- 14 AWG [1.3- 2.1 mm] 5913-BK                             -  5913 0.09 2.29 0.47 11.94

   For environmentally sealed connector shells to hold Powerpole                                                                                 www.andersonpower.com - 35 -
   15-180 connectors, see APP's SPEC Pak product series on our
   website, www.andersonpower.com

All Data Subject To Change Without Notice
                     Powerpole Connectors
                     - PP120: up to 240 Amps

SECTION 2                                                                              PP120 series Powerpole housings are designed
                                                                                       to accommodate up to 1/0 (50 mm) wires and handle
   Powerpole PP120                                                                    high currents up to 240 amps. Reducing bushings allow
                                                                                       PP120 to accept down to #8 (10 mm) wires. Multiple
                                                                                       colors of stackable housings combine with APP's low
                                                                                       resistance flat wiping technology to offer powerful
                                                                                       connection capability.

                                                                                        Large Wire Range Accommodates up to 1/0 (50mm) Wire
                                                                                         Reducing bushings allow as small as #8 (10 mm) wire to be used

                                                                                        Low Resistance Silver Plated Copper Contacts
                                                                                        Allows currents up to 240 amps

                                                                                        UL Rated for Hot Plugging up to 60 Amps
                                                                                        Great for battery or other applications where the ability to
                                                                                         interrupt circuits is required

                     | PP120 ORDERING INFORMATION |

                     PP120 Housings

                     The second to largest Powerpole housing can be used with

                     wire contacts for up to 1/0 AWG [50mm] or busbar contacts.

                     Description       -------- Part Numbers --------                  [ 22.2 ]
                                                                                        0.88
                     Minimum Quantity ... 500       50 .......                                                                          [ 69.9 ]
                                                                                                     [ 22.2 ]                            2.75
                     Red               1321G3-BK 1321G3                                                0.88
                                                                                                                                                [ 117.5 ]
                     Green             1321G4-BK 1321G4                                                                                           4.63     [ 23.7 ]
                                                                                                                                                            0.93
                     Black             1321G1-BK 1321G1

                     White             1321G2-BK 1321G2

                     Blue              1321-BK      1321

                     Gray              1321G8-BK 1321G8

                     PP120 Silver Plated Wire Contacts

                     Silver plated contacts offer superior electrical performance and durability up to 10,000 mating cycles.

                     New contacts for #1 to 1/0 AWG (35 to 50 mm) offer extended capability in the same housings.

                                  Mating                                          -A-  -B-

                     AWG mm Force -------- Loose Piece Part Numbers --------     inches mm inches mm

                     Minimum Quantity ........ 600  500         50                ....................................................

                     1/0 53.5 Low      1323G2-BK          -     1323G2            0.52 13.21 0.44 11.18

                     1      42.4 Low   1323G1-BK          -     1323G1            0.47 11.94 0.39 9.91

                     2      33.6 Low           - 6811G6-BK 6811G6                 0.44 11.18 0.22 5.59

                     2      33.6 High          - 1319-BK 1319                     0.44 11.18 0.22 5.59

                     4      21.1 Low           - 6811G5-BK 6811G5                 0.44 11.18 0.30 7.62

                     4      21.1 High          - 1319G4-BK 1319G4                 0.44 11.18 0.30 7.62

                     6      13.3 Low           - 6811G4-BK 6811G4                 0.44 11.18 0.34 8.64

                     6      13.3 High          - 1319G6-BK 1319G6                 0.44 11.18 0.34 8.64

                                                                                            [ 21.3 ]                                    [ 50.8 ]
                                                                                             0.84                                         2.0
                                                                                              B
                                                                                                                                                           [ 10.4 ]
                                                                                                A                                                           0.41

- 36 - www.andersonpower.com                                                                                                                      All Data Subject To Change Without Notice
| PP120 SPECIFICATIONS |

Electrical                                                Mechanical

Current Rating Amperes                     UL 1977  CSA  Wire Size Range                                                                           AWG          mm
                                                     155                                                                                                         5.3 to 53.5
Singlepole UL 1977 (1/0 AWG)                240      110                                                                                            10 to 1/0    mm
                                                                                                                                                                 15.240
2x2 Block UL 1977 (1/0 AWG)                 200                                                                                                                  C
                                                                                                                                                                 -20 to 105
                                                          Max. Wire Insulation Diameter                                                             in.
                                                                                                                                                                 N
Voltage Rating AC/DC                                                                                                                                0.600        36
                                                                                                                                                                 N
UL 1977                                     600                                                                                                                  267

                                                          Operating Temperature                                                                    F

Dielectric Withstanding Voltage                                                                                                                     -4 to 221

Volts AC                                    2,200         

                                                          Mating Cycles No Load by Plating Silver (Ag)

Avg. Mated Contact Resistance Milliohms                                Wire Contacts                                                               10,000

5 1/2" of #2 AWG wire                       0.136                                                                                                                                SECTION 2

                                                          Avg. Mating / Unmating Force                                                              Lbf.                       Powerpole PP120

UL Hot Plug Current Rating Amperes                                                                                                                  8

250 cycles at 120V DC                       60A           

                                                          Min. Contact / Spring Retention Force Lbf.

                                                                                                                                                    60

Materials                                                 Protection

Housing                       Polycarbonate               Touch Safety with Wire Contacts
Plastic Resin                Stainless Steel
Contact Retention Spring                                                                                      IEC 60529  IP10

Housing Flammability Rating                         Based on: 105C rated or better cable of the largest size, Properly calibrated APP recommended tooling, and
                                                    a 25C ambient temperature. UL rating not to exceed the maximum operating temperature. CSA rating below
UL94                          V-0                   a 30C temperature rise.

Contact                       Copper Alloy          Limited by the thermal properties of the connector plastic housing.
Base                         Silver                Use APP recommended tooling only. Alternate tools may adversely affect the performance of our connectors
Plating
                                                    along with UL and CSA recognition.

Contact Termination Methods

Crimp                        Wire Contacts

Hand Solder                   Wire Contacts

| PP120 TEMPERATURE CHARTS |

                      PP120 Singlepole                                                                                                PP120 Multipole
         Temperature Rise at Constant Current                                                                          Temperature Rise at Constant Current

60                                                                                                             60

50                                                                                                             50

Temperature (C)40                                                                                             40
                                                                                             Temperature (C)
30                                                                                                             30

20                                                                                                             20

10                                                                                                             10

0     0      50 100 150 200 250                                                                                0   0      50 100 150 200 250

                   Amperes Applied                                                                                                 Amperes Applied

          1/0 AWG             1 AWG         2 AWG                                                                         1/0 AWG  1 AWG                 2 AWG
            4 AWG             6 AWG                                                                                         4 AWG  6 AWG

NOTE: Temperature rise charts are based on a 25C ambient temperature.
          Derating charts on the following page.

All Data Subject To Change Without Notice                                                                                                                        www.andersonpower.com - 37 -
                                                             PP120 Singlepole                                                           PP120 Multipole
                                                  Derating vs. Ambient Temperature                                          Derating vs. Ambient Temperature
                                       125                                                                     125

                     Temperature (C)  100                                                   Temperature (C)  100

                                       75                                                                      75

                                       50                                                                      50

                                       25     50 100 150 200            250 300                                25      50 100 150 200                     250 300
                                           0                               2 AWG                                    0            Amperes Applied             2 AWG

                                                       Amperes Applied

SECTION 2                                     1/0 AWG          1 AWG                                                   1/0 AWG                     1 AWG
                                                4 AWG          6 AWG                                                     4 AWG                     6 AWG
   Powerpole PP120
                     | Powerpole PP120 Accessories |

                     Mounting Clamp

                     Mounting clamps can be used for fastening a block of Powerpole 120 series housings to a
                     panel. Connector blocks must be a complete square for the clamps to work properly. Fastening
                     hardware not included.

                     Description              - Part Numbers -                                                         Mounting Clamp
                                                                                                                                  Panel
                     Minimum Quantity ... 20 sets of 2 ......

                     2 Pole                            1464G1

                     3 Pole                            1464G2

                                                                                                                                                                    2 Pole                 3 Pole

                     Retaining Pins

                     Retaining pins are used to keep stacked Powerpole 120 series housings from
                     separating. Retaining pins are inserted in the circular opening between two
                     housings stacked side by side. Dimension B is +/- 0.015 in or 0.38 mm.

                                                                                             Dimensions

                                                                                    - A -                              -B-

                     Description              ----- Part Numbers -----  inches               mm inches mm

                     Minimum Quantity ... 1,000                100      .........................................................................

                     1 Block High             111812P7 110G19           0.196 / 0.207 4.98 / 5.26 0.560 14.220

                     2 Block High             111812P8 110G20           0.196 / 0.207 4.98 / 5.26 1.500 38.100

                                                                                                                                                                    B
                                                                                                                                                                                        A

                     Reducing Bushings

                     Use with contact part number 1319-BK or 6811G6-BK to allow a smaller wire to be used

                     with the connector. Electrical capability is derated with smaller wire.

                                                                                                                       Dimensions

                                                                                                                            - ID -

                     Contact Barrel Size Wire Size                                  --------- Part Numbers --------- inches mm                                      [ 21.4 ]
                                                                                                                                                                     0.84
                     Minimum Quantity ................................................... 2,000 1,000 100 ........................

                     #2 AWG [33.6 mm] #4 AWG [21.2 mm]                            5919-BK  -                      5919 0.28 7.11

                     #2 AWG [33.6 mm] #6 AWG [16 mm]                              -        5920-BK 5920 0.23 5.84                                       ID                               [ 8.4 ]
                                                                                                                                                                                           0.33
                     #2 AWG [33.6 mm] #10 - 8 AWG [5.3 - 8.4 mm] 5921-BK                                          5921 0.18 4.57

                     For environmentally sealed connector shells to hold Powerpole
                     15-180 connectors, see APP's SPEC Pak product series on our
                     website, www.andersonpower.com

- 38 - www.andersonpower.com                                                                                                                                        All Data Subject To Change Without Notice
Powerpole Connectors                                                      PP180 are the largest of the Powerpole series housings.                                                               SECTION 2
- PP180: up to 350 Amps                                                    They are designed to accommodate up to 3/0 (70 mm)
                                                                           wires and handle high currents up to 350 amps. Busbar                                                                Powerpole PP180
                                                Wire to Busbar             contacts are also available for power inputs and takeoffs.
                                                                           Color-coded housings minimize user confusion and the
                                                                           potential of cross mating circuits.

                                                                           Low Resistance Silver Plated Copper Contacts
                                                                            Allows currents up to 350 amps

                                                                           UL Rated for Hot Plugging up to 75 Amps
                                                                            Great for battery or other applications where the ability to
                                                                           interrupt circuits is required

                                                                           Busbar Contacts Work with Standard Housings
                                                                            Provides a hot swappable quick disconnect system for busbar
                                                                           power distribution

| PP180 ORDERING INFORMATION |

PP180 Housings

The largest Powerpole housing can be used with wire

contacts for up to 3/0 AWG [85mm] or busbar contacts.

Description   -------- Part Numbers --------

Minimum Quantity ... 250                   50 .......               [ 28.6 ]                    [ 82.6 ]
                                                                      1.13                       3.25
Red           1381G3-BK 1381G3
                                                                                   [ 28.6 ]             [ 129.7 ]
Green         1381G4-BK 1381G4                                                       1.13                  5.5

Black         1381G1-BK 1381G1                                      Front View                      Mated Length                [ 30.0 ]
                                                                                                                                 1.18
White         1381G2-BK 1381G2

Blue          1381-BK                      1381

PP180 Silver Plated Wire Contacts

Silver plated contacts offer superior electrical performance and durability up to 10,000 mating cycles.

New contacts for 2/0 to 3/0 AWG (70 to 85 mm) offer extended capability in the same housings.

                                                                                                         Dimensions

             Mating                                                        -A-                           -B-               -C-  -D-

AWG mm Force ---------- Loose Piece Part Numbers -----------        inches mm inches mm inches mm inches mm

Minimum Quantity ........ 500                    300   250      50   ..............................................................................................................

3/0 85 Low                -                      - 1328G2-BK 1328G2  2.35                    59.69 0.70 17.78 0.58 14.73 1.04 26.42

2/0 67.4 Low              -                1328G1-BK -      1328G1   2.35                    59.69 0.64 16.26 0.49 12.45 1.04 26.42

1/0 53.5 High 1382-BK                            -     -    1382     2.35                    59.69 0.52 13.21 0.44 11.18 1.04 26.42

1      42.4 High 1347-BK                         -     -    1347     2.35                    59.69 0.52 13.21 0.39 9.91 1.04 26.42

2      33.6 High 1383-BK                         -     -    1383     2.35                    59.69 0.52 13.21 0.35 8.89 1.04 26.42

4      21.1 High 1384-BK                         -     -    1384     2.35                    59.69 0.52 13.21 0.30 7.62 1.04 26.42

6      13.3 High 1348-BK                         -     -    1348     2.10                    53.34 0.37 9.40 0.22 5.59 0.80 20.32

                                                                                                                        A
                                                                                               D
                                                                                             C

                                                                                             B                                                                                       [ 12.70 ]
                                                                                                                                                                                       050

All Data Subject To Change Without Notice                                                                                       www.andersonpower.com - 39 -
                     PP180 Silver Plated Busbar Contacts                                                         See Busbar contact drawing on                   [ N/A ]
                                                                                                                 website for further detail.                     1/4-20
                     Use 2 busbar contacts per housing to provide a quick disconnect input or
                     output busbar connection. Busbar contacts are for mating with wire contacts                          [ 109.7 ]                                        [ 25.4 ]
                     only. Part number 180BBS includes lock nuts. Locknuts must be ordered                                   4.3                                              1.0
                     separately for 180BBS-BK.

                                         Mating                                                                                           [ 2.7 ]
                                                                                                                                          0.50

                     Thread              Force          ------ Loose Piece Part Numbers ------

                     Minimum Quantity ................  1,000            120   10 .....

                     Busbar 1/4-20       High           180BBS-BK 180BBS       -

                     Lock Nut 1/4-20     N/A            H1216P7       110G56 110G55                                                                [ 4.6 ]
                                                                                                                                                   0.18

SECTION 2            | PP180 SPECIFICATIONS |

   Powerpole PP180  Electrical                                                                 Mechanical

                     Current Rating Amperes                          UL 1977  CSA              Wire Size Range                      AWG           mm
                      Singlepole (wire-wire) (3/0 AWG)                350      230                                                                 5.3 to 85
                      2x2 Block (wire-wire) (3/0 AWG)                 350                                                            10 to 3/0     mm
                      Singlepole (wire-busbar) (1/0 AWG)              180                                                                          22.860
                                                                                                                                                   C
                                                                                                                                                   -20 to 105
                                                                                                Max. Wire Insulation Diameter        in.
                                                                                                                                                   N
                                                                                                                                     0.900         44
                                                                                                                                                   N
                                                                                                                                                   534

                     Voltage Rating AC/DC                                                       Operating Temperature               F

                     UL 1977                                          600                                                            -4 to 221

                                                                                                

                     Dielectric Withstanding Voltage                                            Mating Cycles No Load by Plating     Silver (Ag)

                     Volts AC                                         2,200                     Wire and Busbar Contacts             10,000

                                                                                                

                     Avg. Mated Contact Resistance Milliohms                                   Avg. Mating / Unmating Force         Lbf.

                     6" of 1/0 AWG wire                               0.100                     Wire & Busbar Contacts               10

                                                                                                

                     UL Hot Plug Current Rating Amperes                                         Min. Contact / Spring Retention Force Lbf.

                     250 cycles at 120V DC                            75A                                                            120

                     Materials                                                                  Protection

                     Housing                                                                    Touch Safety with Wire Contacts
                      Plastic Resin
                      Contact Retention Spring          Polycarbonate                           IEC 60529        IP10
                                                        Stainless Steel

                     Housing Flammability Rating

                     UL94                               V-0

                     Contact                            Copper Alloy          Based on: 105C rated or better cable of the largest size, Properly calibrated APP recommended tooling, and
                      Base                              Silver                 a 25C ambient temperature. UL rating not to exceed the maximum operating temperature. CSA rating below a
                      Plating                                                  30C temperature rise.

                     Contact Termination Methods                               Limited by the thermal properties of the connector plastic housing.
                      Crimp                                                   Use APP recommended tooling only. Alternate tools may adversely affect the performance of our connectors
                      Hand Solder
                      Wrench / Socket*                                          along with UL and CSA recognition.

                     *Busbar Contacts Only

- 40 - www.andersonpower.com                                                                                                                       All Data Subject To Change Without Notice
| PP180 TEMPERATURE CHARTS |

                                       PP180 Singlepole                                                         PP180 Multipole
                                                                                                 Temperature Rise at Constant Current
                         Temperature Rise at Constant Current                             60
                  60

                  50                                                                      50

Temperature (C)  40                                                    Temperature (C)  40

                  30                                                                      30

                  20                                                                      20

                  10                                                                      10

                  0                                                                       0                                              SECTION 2
                     0 50 100 150 200 250 300 350                                            0 50 100 150 200 250 300 350
                                                                                                                                       Powerpole PP180
                                Amperes Applied                                                         Amperes Applied

                       3/0 AWG  2/0 AWG          1/0 AWG                                       3/0 AWG  2/0 AWG          1/0 AWG
                         1 AWG    2 AWG            4 AWG                                         1 AWG    2 AWG            4 AWG

                                         PP180 Singlepole                                                         PP180 Multipole
                             Derating vs. Ambient Temperature                                        Derating vs. Ambient Temperature
                                                                                          125
                  125

Temperature (C)  100                                                   Temperature (C)  100

                  75                                                                      75

                  50                                                                      50

                  25                                                                      25
                      0 50 100 150 200 250 300 350 400                                        0 50 100 150 200 250 300 350 400

                                Amperes Applied                                                         Amperes Applied

                       3/0 AWG  2/0 AWG          1/0 AWG                                       3/0 AWG         2/0 AWG   1/0 AWG
                         1 AWG    2 AWG            4 AWG                                         1 AWG           2 AWG     4 AWG

NOTE: Temperature rise charts are based on a 25C ambient temperature.

All Data Subject To Change Without Notice                                                                        www.andersonpower.com - 41 -
                     | Powerpole PP180 Accessories |

                     Mounting Clamp                                                                           Mounting Clamp
                                                                                                                        Panel
                     Mounting clamps can be used for fastening a block of
                     Powerpole 180 series housings to a panel. Connector
                     blocks must be a complete square for the clamps to work
                     properly. Fastening hardware not included.

                     Description   - Part Numbers -

                     Minimum Quantity ... 20 sets of 2 .....                                                                                                      2 Pole  3 Pole

                     2 Pole        1465G1

                     3 Pole        1465G2

SECTION 2            Retaining Pins

   Powerpole PP180  Retaining pins are used to keep stacked Powerpole 180 series housings from separating.
                     Retaining pins are inserted in the circular opening between two housings stacked side by side.
                     Dimension "B" is +/- .015 in or .38 mm.

                                                                                                   Dimensions

                                                                              -A-                              -B-

                     Description   ----- Part Numbers -----                   inches                           mm

                     Minimum Quantity ... 1,000     100 ..................................................................................

                     1 Block High  111812P6 110G18 0.196 / 0.207 4.98 / 5.26 1.000 25.400

                     2 Block High  111812P8 110G20 0.196 / 0.207 4.98 / 5.26 1.500 38.100

                     

                                                                                                                                                                  B
                                                                                                                                                                                      A

                     Reducing Bushings

                     Use with contact part number 1382-BK to allow a smaller wire to be used with the connector. Electrical

                     capability is derated with smaller wire.

                                                                                                                                            Dimensions

                                                                                                                                            - ID -

                     Contact Barrel Size Wire Size            ----------------- Part Numbers ---------------- inches mm

                     Minimum Quantity ..................................................... 1,500  1,000 500        100 ............................

                     1/0 AWG [53.5 mm] #1 AWG [42.4 mm]     -                                    -  5687-BK 5687 0.39 9.91                            [ 25.4 ]
                                                                                                                                                          1.0
                     1/0 AWG [53.5 mm] #2 AWG [33.6 mm]     5690-BK -                               -             5690 0.34 8.64                                         ID
                                                                                                                                                                          Wire Entrance
                     1/0 AWG [53.5 mm] #4 AWG [21.2 mm]     -                                    5693-BK -        5693 0.27 6.86

                     1/0 AWG [53.5 mm] #6 AWG [13.3 mm]     -                                    5663-BK -        5663 0.22 5.59

                     1/0 AWG [53.5 mm] #10 - 8 AWG [5.3 - 8.4 mm] 5648-BK -                         -             5648 0.19 4.83

                     For environmentally sealed connector shells to hold Powerpole
                     15-180 connectors, see APP's SPEC Pak product series on our
                     website, www.andersonpower.com

- 42 - www.andersonpower.com                                                                                                                                      All Data Subject To Change Without Notice
Powerpole
- Tooling Information

W ire Size Loose Piece Part Numbers Loose Piece Contact Crimp Tool                                               Reeled Part Numbers Reeled Contact Crimp Tools

AWG mm                Tin                 Silver                Pneumatic                               Number    Tin         Silver         ATS      ATS    Air Feed
                     Plating               Plating   Hand Bench                          + Locator of Crimps     Plating       Plating     Applicator  Press     Kit*
                                                    Tool or Tool + Die

                                                                        PP15 / 45 Flat Wiping Power & Ground

16 / 20  1.3 / 0.52  N/A                   1332                         1367G1                                     N/A           N/A       N/A         N/A    N/A
12 / 16
16 / 20  3.3 / 1.3   N/A                   1331     1309G2                                                       262G1         262G2
16 / 20                                                or                                                        200G2L        200G4L
         1.3 / 0.52 262G1-LPBK 262G2-LPBK                                                                        269G2                     1385519-1
                                                    1309G8                                                       261G1            N/A
         1.5 / 0.52 200G2L-LPBK 200G4L-LPBK                                                                      261G2          261G4      TBD
                                                                                                                 269G1          261G3
16 / 20 1.3 / 0.52 269G2-LPBK              N/A                                                                   269G3                     1385519-1                             SECTION 2
                                                                                                                 200G1L          N/A
12 / 16 3.3 / 1.3 261G1-LPBK 261G4-LPBK                                 N/A     N/A      N/A      Single         201G1H          N/A       1385520-1                           Powerpole Tooling
                                                                                                                 1830G1        200G3L
10 / 14 5.3 / 2.1 261G2-LPBK 261G3-LPBK 1309G3                                                                                 201G3H      1385458-1 1725900-2 1424266-1
                                                                                                                               1830G2                  or     or
12 / 16 3.3 / 1.3 269G1-LPBK               N/A      or                                                                                     1385520-1 [3-54500-1] [354578-1]

                                                    1309G8

10 / 14 5.3 / 2.1 269G3-LPBK               N/A                                                                                             1385458-1

10 / 14  6.0 / 2.1 200G1L-LPBK 200G3L-LPBK 1309G6                                                                                          1385460-1
10 / 14  6.0 / 2.1 201G1H-LPBK 201G3H-LPBK or
10 / 14                                                                                                                                    1385460-1
                                                                1309G8
         6.0 / 2.1 1830G1-LPBK 1830G2-LPBK                                                                                                 1385460-1

                                                                                         PP75

#6       13.3                              1307                                 1388G6                           265G5                     1385523-1 2-565435-2 692655-1
                                           5900                                                                                       N/A
#8       8.4         N/A                   5952     1309G4              1387G1           1389G6   Single
                                                                                                                 265G6
                                           5953                                                                                                        1725900-2 1424266-1
                                           5915
#10 / 12 5.3 / 3.3                                                              1388G7                                                     1385522-1   or     or

                                                                                                                                                       [3-54500-1] [354578-1]

1/0      53.5                              1323G2                                         PP120
                                           1323G1                               1388G3
#1       42.4

#2       33.6        N/A                   1319     1368 1387G1                          1389G4 Single                    N/A                          N/A

#4       21.2                              1319G4                               1388G4

#6       13.3                              1319G6

                                                                                         PP180

3/0      85                                1328G2                               1303G12
                                           1328G1
2/0      53.5                                                           1387G2           1304G32  Double
                                            1382
1/0      53.5                                                                   1303G13

#1       42.4        N/A                   1347     1368 1387G1 1388G3 1389G3 Single                                      N/A                          N/A

#2       33.6                              1383                         1387G2 1303G13 1304G32    Double
                                           1384                         1387G1 1388G3 1389G3      Single
#4       21.1                              1348                         1387G2 1303G13 1304G32    Double
                                                                        1387G1 1388G4 1389G3      Single
#6       13.3

* All ATS applicators for APP contacts are air feed style, (except 1385870) and require the press to have an air feed kit installed.
NOTE: See website for the most current information.

All Data Subject To Change Without Notice                                                                                                  www.andersonpower.com - 43 -
Overview of SBS, SB & SBX / SBO
- Main Differentiating Features

SECTION 3                                                                    SBS: The "Storage Battery Safety" connector provides
                                                                             a compact connection with a touch safe interface. The
    Multipole Family                                                         newest series of the Multipole connector continues to add
                                                                             new features and capabilities.

                                                                             SB: Based on the original "Storage Battery" connector that
                                                                             pioneered flat wiping contact technology over a half century
                                                                             ago. Two to three positions in a genderless mechanically-keyed
                                                                             housing are suitable for a wide array of power connection
                                                                             applications.

                                                                             SBX: The addition of auxiliary positions to the SB created
                                                                             the "Storage Battery Auxiliary" connector. Up to 8 auxiliary
                                                                             positions allow expanded capabilities for the Multipole family
                                                                             by allowing intelligent power switching, monitoring of battery
                                                                             charge status, and other signal functions to be integrated
                                                                             into a single connector.

                                                                             SBE: By modifying the SBX housing the "Storage Battery
                                                                             European" connector was created. The SBE housings are
                                                                             molded from a chemical resistant PBT resin and the SBE320
                                                                             features improved touch safety over the SBX350 design.

                                                                             SBO: Designed to meet the needs of connecting office
                                                                             equipment, the "Storage Battery Office" connector is molded
                                                                             out of durable PC like the original SB but incorporates the
                                                                             auxiliary positions of the SBX in a housing similar to the
                                                                             SBE80.

                      Hot Plugging AC or DC                    Genderless Housings
                      Contacts feature a sacrificial tip that  Provide simplified assembly and
                      allow high current circuit interrupt     minimize the number of components

                      Low Resistance Connection                              Keyed & Color Coded Housings
                      Silver or tin plated contacts                          Prevents accidental cross mating
                      inside housings that strongly                          of circuits
                      force the contacts together
                                                                                                                      Compact Power to Size Ratio
                                          Self Securing Design                                                        Maximizes valuable PCB edge
                                          Stainless steel springs create a                                            real estate with a compact high
                                          robust force between the contacts                                           power design
                                          that holds the connector in the
                                          mated condition

                                                                             Auxiliary or Ground Positions
                                                                             For signal transmission or the
                                                                             added safety of a premate
                                                                             ground

- 44 - www.andersonpower.com                                                                                 All Data Subject To Change Without Notice
| MULTIPOLE FAMILY SELECTION GUIDE |

                                           SBS Connector SB Connector  SBX / SBE / SBO Connectors
                                                                                               77
Page Number                                    49          57
Amps Per Pole                               50 - 110   50 - 450                            60 - 350
Volts (UL) Per Pole                                                                           600
Wire Gauge (AWG)                               600        600
Wire Gauge (mm)                             16 - 6    16 - 300                            16 - 300
Number of Power Circuits                   1.3 - 13.3  1.3 - 152                         13.3 - 152
Number of Auxiliary Circuits                  2-3
PCB Mount                                                 2-3                                  2
Bus Bar                                         4           0                                  8
Panel Mount                                                
Hot Plug                                                                                       
Touch Safe                                                                                      
Mechanically Keyed                                                                              
Handle                                                                                          
Air Supply System                                                                              
                                                            

Actual Size - Connector Half                                                                              SECTION 3

                                                                                                        Multipole Family

SB50                                                  SB120            SB175 - 2 Pole

All Data Subject To Change Without Notice                                        www.andersonpower.com - 45 -
                      Actual Size - Connector Half

SECTION 3             SB175 - 3 Pole               SB350

    Multipole Family

                              SBE60 - SBO80       SBE160 - SBX175

- 46 - www.andersonpower.com                                                                All Data Subject To Change Without Notice
                                                                           SBS50

                                                                                      SECTION 3

                                                                                    Multipole Family

                               SBE320 - SBX350                           SBS75X
                                                                                 &

                                                                           SBS75G

Explanation of Mechanical Voltage Keys

Features molded into the mating interface of the connector housing
prevent accidental cross mating of circuits. This molded feature
mechanically keys the connection so that only housings with the same
mating interface can be mated together.

Different mechanical keys can be easily recognized by the color of
the housing. This color coding corresponds to a voltage that industrial
trucks, batteries, and chargers have adopted as a standard to prevent
incompatible voltages from cross mating.

The same mechanical keying and color coding that is so successful for
industrial trucks, is also widely used in power electronics applications.
UPS systems, power supplies, personal mobility, and alternative
energy applications have all used this feature to ensure user safety.

Note: Some housings in the SB50, SB175, and SB350 series have
different colored housings with a shared mechanical keying feature.
Please see the specific data sheet for details.

All Data Subject To Change Without Notice                                  www.andersonpower.com - 47 -
                              | Scratch Pad |

SECTION 3

    Multipole Family

- 48 - www.andersonpower.com                   All Data Subject To Change Without Notice
SBS Connectors
- up to 105 amps

     SBS75G                                                  The patented SBS connector family is designed to
                                                              provide high power in a compact ergonomic housing
                                           SBS75X            with protection against accidental contact with live circuits.
                                           Wire to Wire       This is of particular importance in applications where
                                                              DC voltages exceed 30 volts and can be health
                                                              threatening.                                                                 SECTION 3

                                                              Wire-to-wire and wire-to-board configurations both                         SBS
                                                              provide power contacts rated up to 105 amps. The
                                                              SBS75X offers up to 4 mate-last break-first auxiliary
                                                              power contacts rated up to 20 amps. The SBS75G
                                                              features a third first-mate last-break ground or power
                                                              contact. All contact positions are rated for circuit
                                                              interruption (hot plugging).

                                                               Touch Safe Interface
                                                              - Can safely be used in through panel applications
                                                              - Minimizes potential contact with live circuits per IEC 60950

                                                               Wire-to-Wire and Wire-to-Board Configurations
                                                                 Allows one connector to meet multiple needs

                                                               Ground or Auxiliary Contacts Integrated into the
                                                                One Piece Housing
                                                                Meets all connection requirements in one compact
                                                                connector housing

| SBS ORDERING INFORMATION |

SBS50 Standard Housings

Polycarbonate housings feature 2 positions all finger proof.
Genderless design mates with itself. Mechanical keys are
color coded.

              Voltage                                                                                [ 19.1 ]
                                                                                                      0.75
              Color                                            [ 3.6 ]                                         [ 6.3 ]
                                                              0.14 (2)                                         0.25
Description Code ----------- Part Numbers -----------

Minimum Quantity ......  500               50 ...

Red           24V        SBS50RED-BK SBS50RED

Gray          36V        SBS50GRA-BK SBS50GRA

Blue          48V        SBS50BLU-BK SBS50BLU                                                                           [ 36.1 ]
                                                                                                                          1.42
Green         72V        SBS50GRN-BK SBS50GRN
                                                                                                               Material ID
Black         80V        SBS50BLK-BK SBS50BLK                 [ 18.0 ]                                         P = Chemical Resistant
                                                               0.71
Brown         96V        SBS50BRN-BK SBS50BRN                                                                                  [ 16.5 ]
                                                                          [ 55.8 ]                                              0.65
White         192V SBS50WHT-BK SBS50WHT                                     2.20

SBS50 Chemical Resistant (CR) Housings                                                      [84.8]
                                                                                              3.34
Same features as the standard housings, but molded out of a

chemical resistant PBT/ PC blend. Suitable for use to -40C.

              Voltage

              Color

Description Code ------------ Part Numbers -------------

Minimum Quantity ......  500               50 ...

Red           24V        PSBS50RED-BK PSBS50RED

Gray          36V        PSBS50GRA-BK PSBS50GRA

Blue          48V        PSBS50BLU-BK PSBS50BLU

Green         72V        PSBS50GRN-BK PSBS50GRN

Black         80V        PSBS50BLK-BK PSBS50BLK

Brown         96V        PSBS50BRN-BK PSBS50BRN

All Data Subject To Change Without Notice                                                            www.andersonpower.com - 49 -
           SBS75X Standard Housings                                                                                                 Front View
                                                                                                                            Primary Power Contacts
           Polycarbonate housings feature 4 auxiliary and 2 primary positions
           all finger proof. Genderless design mates with itself, or the PCB
           connector. Mechanical keys are color coded.

                  Voltage                                                                                                                                [ 15.2 ]
                                                                                                                                                          0.60
                  Color

           Description Code ------------ Part Numbers -------------

           Minimum Quantity .....  250  50 ...                                                                              Pin                  Socket

           Black  80V              SBS75XBLK-BK SBS75XBLK                                                                        [ 46.0 ] 1.81

           Brown  96V              SBS75XBRN-BK SBS75XBRN

           SBS75X Chemical Resistant (CR) Housings                                             Bottom View

           Same features as the standard housings, but molded out of a                                                      [ 32.5 ]                                           [ 28.9 ]
                                                                                                                             1.28                                                1.14
           chemical resistant PBT/ PC blend. Suitable for use to -40C.
                                                                                                                               [ 32.5 0.13 ]                 [ 84.8 ]
                  Voltage                                                             [ 55.9 ]                                 0.750 0.005                    3.34
                                                                                       2.20
                  Color                                                                                                                                  Mated Length

           Description Code ------------- Part Numbers --------------                                                                                    Mated Length
                                                                                                                                                                [ 74.9 ]
           Minimum Quantity .....  250  50 ....                                                                                                                   2.95

           Green  72V              PSBS75XGRN-BK PSBS75XGRN

           Black  80V              PSBS75XBLK-BK PSBS75XBLK

                                                                                               Material ID
                                                                                               P = Chemical Resistant

           SBS75X Assembled PCB Connector                                                      Back View [ 15.7 ]                    Side View
                                                                                                                      0.62             [ 46.1 ]
           Fully assembled PCB connector is designed to mate with SBS75X                                                                1.81
           Wire connector. All positions are preloaded with contacts including
           standard mating length auxiliary positions. Press fit board locks
           help secure the connector to the PCB before and after soldering.

                  Voltage

SECTION 3         Color                                                                                                     [ 26.92 ]
                                                                                                                              1.06
   SBS    Description Code ---------------- Part Numbers ---------------                       [ 56.8 ]                        [ 41.00 ]
                                                                                                 2.24                             1.614
           Minimum Quantity .....  100  50 .....                                    [ 4.0 ]                   [ 4.1 ]
                                                                                   0.16 (4)                  0.16 (4)
           Black  80V              SBS75XPRBLK-BK SBS75XPRBLK

                                                                                   See PCB connector drawing on website for further detail.

           SBS75G Wire Housings                                                                                                                           [ 46.0 ]
                                                                                                                                                             1.81
           Polycarbonate housings feature three finger proof positions. The
           center position can be used for pre-mate power or ground. Genderless                                                                                                    [ 15.2 ]
           design mates with itself, or the PCB connector. Mechanical keys are color                                                                                                 0.60
           coded. Inquire with customer service for chemical resistant housings.
                                                                                                                                                Premate Ground / Power
                  Voltage                                                                                                   [ 41.4 ]                                          [ 28.9 ]
                                                                                                                             1.63                                               1.14
                  Color                                                               [ 59.4 ]
                                                                                       2.34                                                                     [ 84.8 ]
           Description Code ------------ Part Numbers -------------                                                                                               3.34

           Minimum Quantity .....  250  50 .....                                                                                                           Mated Length

           Gray   36V              SBS75GGRA-BK SBS75GGRA

           Blue   48V              SBS75GBLU-BK SBS75GBLU                                                                          [ 14.5 ]
                                                                                                                                     0.57
           Black  80V              SBS75GBLK-BK SBS75GBLK
                                                                                                Material ID
           Brown  96V              SBS75GBRN-BK SBS75GBRN                                       P = Chemical Resistant

           SBS75G Assembled PCB Connector                                                      Back View                             Side View          Mated Length
                                                                                                   [ 56.8 ]                           [ 49.6]                 [ 74.9 ]
           Fully assembled PCB connector is designed to mate with SBS75G                            2.24                               1.95                   2.95
           Wire connector. Has press fit board locks to help secure the connector
           to the PCB before and after soldering.

                  Voltage                                                                                    [ 5.7 ]
                                                                                                             0.62
                  Color

           Description Code ---------------- Part Numbers ---------------

           Minimum Quantity .....  100  50 ......                                     [ 4.0 ]                [ 3.4 ]        [ 19.1 ]
                                                                                      0.16                   0.13            0.75
           Black  80V              SBS75GPRBLK-BK SBS75GPRBLK                         TYP                    TYP

           See PCB connector drawing on website for further detail.

- 50 - www.andersonpower.com                                                                                                                     All Data Subject To Change Without Notice
SBS Silver Plated Primary Power Wire Contacts                                                                          [ 7.6 ]
                                                                                                                        0.30
Use two silver plated contacts per housing for the best electrical performance

and durability up to 10,000 mating cycles. Standard contacts are for use in all

primary  power p ositions for SBS 50, 75X, & 75G wire housings.                                                                              [ 39.4 ]
                                                                                                                                                1.55
                                                                       Dimensions                                                                                                  [ 12.4 ]
                                                                                                                                                                                     0.49
                                           Loose Piece                 -A-
                                                                                                                                                                          A
Type         AWG  mm ------ Part Numbers ------ inches mm                                                                                                                                   [ 7.3 ]
                                                                                                                                                                                             0.29
Minimum Quantity .................. 1,000            100 ...................

Standard 6        16      1339G2-BK 1339G2 0.22 5.59

Standard 8        10      1339G5-BK 1339G5 0.19 4.83

Standard 12 to 10 4 to 6 1339G3-BK 1339G3 0.14 3.56

SBS75G Silver Plated Pre-Mate Wire Contacts                                                                                                                            Ground Indicator

Pre-Mate contacts are for the center Pre-Mate position on the SBS75G wire housings.                                    [ 7.6 ]
                                                                                                                        0.30
                                                                       Dimensions

                                           Loose Piece                 -A-

Type         AWG  mm ------ Part Numbers ------ inches mm                                                                                     [  41.9  ++--01..056  ]
                                                                                                                                                  1.65
Minimum Quantity .................. 500                 50 .....................                                                                                                  [ 12.4 ]
                                                                                                                                                                                    0.49
Pre-Mate 6        16      1340G1-BK 1340G1 0.22 5.59
                                                                                                                                                                          A
Pre-Mate 8        10      1340G2-BK 1340G2 0.19 4.83                                                                                                                                        [ 7.3 ]
                                                                                                                                                                                             0.29
Pre-Mate 12 to 10 4 to 6 1340G3-BK 1340G3 0.14 3.56

Pin Contacts for 1x4 Auxiliary Connector

G old plated contacts are availa ble in 4 lengths to allow sequencing of circuits.

Description           AWG mm                                          ----------------- Part Numbers ----------------                                                                                  SECTION 3

Minimum Quantity ....................................................  500             50 ...........                                                                                                 SBS

Standard Length 7.7mm 12                   2.5                         PM16P12S30      PM16P12S30-50

                      16 to 14 1.0 to 1.5                              PM16P1416S30 PM16P1416S30-50                                                      Retention Clip

                      20 to 16 0.75 to 1.0 PM16P1620S30 PM16P1620S30-50                                                                                                           [ 1.60 ]

                      24 to 20 0.50 to 0.75 PM16P2024S30 PM16P2024S30-50                                                         ID                                                0.06

Pre-Mate 9.3mm        12                   2.5                         PM16P12A30      PM16P12A30-50

                      16 to 14 1.0 to 1.5                              PM16P1416A30 PM16P1416A30-50

                      20 to 16 0.75 to 1.0 PM16P1620A30 PM16P1620A30-50                                                                                               L1
                                                                                                                                                         L
                      24 to 20 0.50 to 0.75 PM16P2024A30 PM16P2024A30-50

Pre-Mate 8.5mm        12                   2.5                         PM16P12B30      PM16P12B30-50

                      16 to 14 1.0 to 1.5                              PM16P1416B30 PM16P1416B30-50

                      20 to 16 0.75 to 1.0 PM16P1620B30 PM16P1620B30-50                                                          Auxiliary Pin                              -L-       - L1 -
                                                                                                                                 Contact Lengths                        in. mm     in. mm
                      24 to 20 0.50 to 0.75 PM16P2024B30 PM16P2024B30-50                                                         Standard Length 7.7mm                  0.77 19.6  0.30 7.7
                                                                                                                                 Pre-Mate 9.3mm                         0.83 21.2  0.37 9.3
Post-Mate 6.4mm       12                   2.5                         PM16P12C30      PM16P12C30-50                             Pre-mate 8.5mm                         0.80 20.4  0.33 8.5
                                                                                                                                 Post-Mate 6.6mm                        0.72 18.3  0.25 6.4
                      16 to 14 1.0 to 1.5                              PM16P1416C30 PM16P1416C30-50

                      20 to 16 0.75 to 1.0 PM16P1620C30 PM16P1620C30-50

                      24 to 20 0.50 to 0.75 PM16P2024C30 PM16P2024C30-50

Socket Contacts for 1x4 Auxiliary Connector

S electively gold plate d contacts offer low resistance and durability up to 10,000 mating cycles.                                                                      [ 19.6 ]
                                                                                                                                                                        0.77

Description AWG mm -------------------- Part Numbers -------------------

Minimum Quantity ..................................  500                           50  .............

Socket Contact 12 2.5 PM16S12S32 PM16S12S32-50                                                                                             ID

16 to 14 1.0 to 1.5 PM16S1416S32 PM16S1416S32-50                                                                                                 Retention             Socket              [ 2.6 ]
                                                                                                                                                        Clip             Insert             0.10

20 to 16 0.75 to 1.0 PM16S1620S32 PM16S1620S32-50

24 to 20 0.50 to 0.75 PM16S2024S32 PM16S2024S32-50

                                                                                                                                 Auxiliary Socket Contacts
                                                                                                                                 Crimp Barrel ID

                                                                                                                                 Wire Gauge in. mm.

                                                                                                                                 #24 / 20         0.04 1.1

                                                                                                                                 #20 / 16         0.07 1.7
                                                                                                                                 #16 / 14         0.08 2.1
                                                                                                                                 #12              0.10 2.6

All Data Subject To Change Without Notice                                                                                                                www.andersonpower.com - 51 -
           | SBS CONNECTOR SPECIFICATIONS |

           Electrical                                                        Mechanical

           Current Rating Amperes                   UL 1977 CSA/TUV         Wire Size Range                         AWG             mm

           Primary Power (6 AWG)                     110        75           Power Contacts                          16 to 6         1.3 to 13.3

           Auxiliary (12 AWG)                        20         10           Auxiliary Contacts                      24 to 12        0.25 to 3.3

                                                                             

           Voltage Rating AC/DC                                              Max. Wire Insulation Diameter           in.             mm

           UL 1977                                   600                     SBS75G Power & Ground                  0.380           9.652

                                                                             SBS50 & SBS75X Power Contacts         0.410           10.414

           Dielectric Withstanding Voltage                                   SBS75X Auxiliary Contacts              0.140           3.600

           Volts AC                                  2,200                  

                                                                             Operating Temperature                  F              C

           Avg. Mated Contact Resistance Milliohms                          Standard                                -4 to 221 -20 to 105

           Power & Ground: 1 1/4" of #6 AWG wire 0.200                       Chemical Resistant                      -40 to 221 -40 to 105

           Auxiliary: Wire & PCB                     3.000                  

                                                                             Mating Cycles No Load by Plating        Silver (Ag) Tin (Sn)         Gold (Au)

           UL Hot Plug Current Rating Amperes - 250 cycles at 120V DC        Power & Ground Contacts Wire            10,000

           Wire & PCB Power                          50A                     Power & Ground Contacts PCB                             1,500

           Wire & PCB Auxiliary                      5A                      Auxiliary Contacts                                                   10,000

                                                                             

           UL Ground Short Time Current Test - SBS75G Wire & PCB             Avg. Mating / Unmating Force            Lbf.            N

           1530 Amps, #6 AWG Wire                    6 seconds               SBS75X and SBS75G Wire to Wire        16              70

                                                                             SBS50 Wire to Wire                     8               36

                                                                             SBS75X and SBS75G Wire to PCB         8               36

                                                                             

                                                                             Min. Contact / Spring Retention Force   Lbf.            N

           Materials                                                         Power, Standard Housing                 50              222

           Housing                                                           Power, Chem. Resistant Housing          30              133
            Standard Plastic Resin
            Chem. Resistant Resin           Polycarbonate                    Aux. Standard Housing                   15              67
            Contact Retention Spring        Polycarbonate / PBT blend
                                            Stainless Steel                  Aux. Chem. Resistant Housing            10              44

                                                                             

                                                                             PCB Specifications

           Housing Flammability Rating                                       Mounting Style                          Plated Through Hole

SECTION 3  UL94                             V-0                              Max PCB Thickness- in. [mm]             0.093 [2.4]

   SBS                                                                      Recommended Traces Power & Ground #6 AWG Cross Section

           Wire Power & Ground Contact Silver Plated Copper Alloy            Recommended Traces Auxiliary            #12 AWG Cross Section

                                                                             

           PCB Power & Ground Contact Tin Plated Copper Alloy                Min. Creepage / Clearance Distance PCB in.              mm

                                                                             Power to Aux. Creepage SBS75X          0.41            10.4

           SBS75X Auxiliary Contacts                                         Power to Aux. Clearance SBS75X         0.24            6.1
            Pin
            Socket                          Copper alloy, Au over Ni         Power to Ground Creepage SBS75G        0.35            8.9
            Socket Body                     BeCu, Au over Ni
            Retention Clip                  Copper alloy, Sn bright over Ni  Power to Ground Clearance SBS75G       0.26            6.7
                                            Stainless Steel
                                                                             Auxiliary Creepage SBS75X              0.12            3.0

                                                                             Auxiliary Clearance SBS75X             0.12            3.0

           PCB Press Fit Retainers          Brass - Tin Plated               Protection

                                                                             Touch Safety with Wire Contacts & PCB Mating Interface

           Contact Termination Methods                                       IEC 60950           Pass
            Crimp
            Hand Solder                     Wire Contacts                    IEC 60529           IP20
            Solder Dip                      Wire and PCB Contacts
            Wave Solder                     PCB Contacts
                                            PCB Contacts

           Auxiliary contacts are available for SBS75X only.
           SBS75X and SBS75G PCB connectors are designed to mate only with the wire connector of the same series.

            Based on: 105C rated or better cable of the largest size, Properly calibrated APP recommended tooling, and a 25C ambient temperature. UL rating not to exceed
             the maximum operating temperature. CSA rating below a 30C temperature rise.

            Limited by the thermal properties of the connector plastic housing.
            Use APP recommended tooling only. Alternate tools may adversely affect the performance of our connectors along with UL and CSA recognition.

- 52 - www.andersonpower.com                                                                                               All Data Subject To Change Without Notice
| SBS CONNECTOR TEMPERATURE CHARTS |

                             SBS75x Primary Contacts Only                                 SBS75x Primary Contacts Only                                                   SBS50
                                                                                          Derating vs. Ambient Temperature                             Temperature Rise at Constant Current
                         Temperature Rise at Constant Current
                  60                                                              125.0                                                        60

                  50                                                                                                                           50

Temperature (C)                                                Temperature (C)  100.0                                      Temperature (C)

                  40                                                                                                                           40

                  30                                                              75.0                                                         30

                  20                                                                                                                           20

                                                                                  50.0

                  10                                                                                                                           10

                  0                                                               25.0    20 40 60 80 100 120 140                              0
                     0 10 20 30 40 50 60 70 80 90 100 110 120                          0                                                         0 20 40 60 80 100 120
                                                                                                                                                                    Amperes Applied
                      Amperes Applied                                                     Amperes Applied

                       6 AWG                8 AWG                                          6 AWG   8 AWG                                            6 AWG  10 AWG  12 AWG
                      10 AWG               12 AWG                                         10 AWG  12 AWG

                           SBS75x Auxiliary Contacts @ 10A                               SBS75x Auxiliary Contacts @ 10A                                                  SBS50
                         Temperature Rise at Constant Current                             Derating vs. Ambient Temperature
                  60                                                                                                                                      Derating vs. Ambient Temperature
                                                                                  125.0                                                        125

                  50

Temperature (C)                                                Temperature (C)  100.0                                      Temperature (C)  100

                  40

                  30                                                              75.0                                                         75                                              SECTION 3

                  20                                                                                                                                                                         SBS

                                                                                  50.0                                                         50

                  10

                  0                                                               25.0                                                         25
                     0 10 20 30 40 50 60 70 80 90 100 110                              0 10 20 30 40 50 60 70 80 90 100 110                        0 20 40 60 80 100 120 140

                      Amperes Applied                                                     Amperes Applied                                                            Amperes Applied

                       6 AWG   8 AWG                                                       6 AWG   8 AWG                                            6 AWG  10 AWG  12 AWG
                      10 AWG  12 AWG                                                      10 AWG  12 AWG

                            SBS75x Auxiliary Contacts @ 20A                              SBS75x Auxiliary Contacts @ 20A
                                                                                          Derating vs. Ambient Temperature
                          Temperature Rise at Constant Current
                  60                                                              125.0

                  50

Temperature (C)                                                Temperature (C)  100.0

                  40

                  30                                                              75.0

                  20

                                                                                  50.0

                  10

                  0                                                               25.0
                     0 10 20 30 40 50 60 70 80 90 100 110                               0 10 20 30 40 50 60 70 80 90 100110

                      Amperes Applied                                                     Amperes Applied

                       6 AWG   8 AWG                                                       6 AWG   8 AWG
                      10 AWG  12 AWG                                                      10 AWG  12 AWG

NOTE: Temperature rise charts are based on a 25C ambient temperature.

All Data Subject To Change Without Notice                                                                                                           www.andersonpower.com - 53 -
                                        SBS75G All Contacts Powered                                 SBS75GPR All Contacts Powered                                  SBS75G Primary Contacts Only
                                                                                                   Temperature Rise at Constant Current                                   No Power Center Contact
                                    Temperature Rise at Constant Current
                             60                                                             60                                                                    Temperature Rise at Constant Current
                                                                                                                                                           60

                             50                                                             50                                                             50

           Temperature (C)  40                                           Temperature (C)  40                                           Temperature (C)  40

                             30                                                             30                                                             30

                             20                                                             20                                                             20

                             10                                                             10                                                             10

                             0                                                              0                                                              0
                                0 20 40 60 80 100 120                                          0 10 20 30 40 50 60 70 80 90 100                               0 10 20 30 40 50 60 70 80 90 100 110 120

                                    Amperes Applied                                                        Amperes Applied                                        Amperes Applied

                                     6 AWG   8 AWG                                                          6 AWG             8 AWG                                6 AWG     8 AWG
                                    10 AWG  12 AWG                                                         10 AWG            12 AWG                               10 AWG    12 AWG

                                          SBS75G All Contacts Powered                                 SBS75GPR All Contacts Powered                                  SBS75G Primary Contacts Only
                                        Derating vs. Ambient Temperature                                                                                                    No Power Center Contact
                             125                                                                       Derating vs. Ambient Temperature
                                                                                            125                                                                       Derating vs. Ambient Temperature
                                                                                                                                                           125

           Temperature (C)  100                                          Temperature (C)  100                                          Temperature (C)  100

                             75                                                             75                                                             75

                             50                                                             50                                                             50

                             25     20 40 60 80 100 120 140                                 25                                                             25     20 40 60 80 100 120 140
                                 0                                                              0 20 40 60 80 100 120                                          0

                                    Amperes Applied                                                        Amperes Applied                                        Amperes Applied

SECTION 3                            6 AWG   8 AWG                                                          6 AWG             8 AWG                                6 AWG     8 AWG
                                    10 AWG  12 AWG                                                         10 AWG            12 AWG                               10 AWG    12 AWG
   SBS
           NOTE: Temperature rise charts are based on 25 C ambient temperature.

           | SBS Accessories |

           Mounting Clamp for SBS50                                                                               [ 20.8 ]  [ 20.8 ]    [ 20.8 ]                 [ 1.5 ]
                                                                                                                    0.82      0.82        0.82 [ 4.6 ]            0.06
           Mounting clamps can be used for fastening a SBS50 series                                                                               0.18 TYP
                                                                                                                                                                            [ 26.4 ]
           housings to a panel. Fastening hardware not included.                                                                                                             1.04

           Description                      --- Part Number ---

           Minimum Quantity .......................... 20 sets of 2 .....                                  [ 25.1 ]                      [ 33.5 ]
                                                                                                            0.99                          1.32
           Panel Mount Bracket for SBS50            1466G1

                                                                                                                                                                  [ 28.2 ]
                                                                                                                                                                   1.11

                                                                                                                             [ 50.0 ]
                                                                                                                              1.97

           T-Handle for SBS50 and SBS75X

           The "T" handle makes mating and unmating the connector easier. The

           non-conductive red plastic material is strong and safe. (2) Self tapping

           s crews are used to  secure the handle to the conn ector housing.

           Description                               ---------- Part Numbers ----------

           Minimum Quantity ............................... 1,000                           50 ..........

           Red "T" Handle + Hardware Bag             -                    SBS50-HDL-RED

           Hardware Bag (2 Screws)                   -                    104G17

           Red "T" Handle Only                       113899P1                               -

           #8 x 5/8" Screw (Order 2 Per Handle) H1120P41                                    -

           

- 54 - www.andersonpower.com                                                                                                                                      All Data Subject To Change Without Notice
T-Handle for SBS75G

The "T" handle makes mating and unmating the connector easier. The non-conductive

red plastic material is strong and safe. (2) Machine screws and lock nuts.

Description                                      --- Part Number ---

Minimum Quantity ..............................           50 .........

Red "T" Handle + Hardware Bag                    SBS75GHDL-RED



Dust Cover SBS50                                                                                                                                                               Shown with the SB50

Prevents dust and dirt from entering the mating interface of the                                                                                                             Slide cover over
                                                                                                                                                                             mating end.
connector when unmated. NOTE: Not a Hermetic Seal.

Description                                      ---- Part Number ----

Minimum Quantity ............................... 500            50 ...

Dust Cover with Lanyard Strap, Red 113890P1 134G1

Cable Clamps for SBS50

Durable metal cable clamps securely hold cables to prevent accidental strain or pulls from dislodging
wire or contacts from the housing. Cable clamps are recommended for solder terminated wires. 5905

                                                 Cable Size

                                                 AWG or                 mm or                                                                                           Shown with the SB50
                                                                                                                                                                         Bolt on bundled
Description                                      (Inches O.D.) (mm O.D.)                   ----- Part Numbers -----                                                      conductors.                    SECTION 3

Minimum Quantity ............................................................................................ 500       50 ...                 The given wire O.D. information is an esti-            SBS
                                                                                                                                               mate. Cable clamps should be evaluated for
Self Attaching for Discrete Conductor 8 to 6                            10                 990-BK                       990                    performance with the actual wire to be used.

Self Attaching for Discrete Conductor 12 to 10                          4 to 6             990G2-BK 990G2

Bolt On for Discrete Conductor                   12 to 6                4 to 10            990G1-BK 990G1

Bolt On for Bundled Conductor                    (0.320 to 0.450) (4.27 to 11.43) 5905-BK 5905

                                                                                           990

                                                          Self attaching discrete conductor.

Cable Clamps for SBS75X with Integral Handle

Rugged chemical resistant PBT/ PC plastic cable clamps securely hold cables to prevent accidental strain or pulls from dislodging

wire or contacts from the housing. Cable clamps are recommended for solder terminated wires.

                                                 Cable Size AWG or mm or

Description                                      (Inches O.D.)              (mm O.D.)                                   ------------------ Part Numbers -------------------

Minimum Quantity .....................................................................................................  100 25 .....

Large Wire Clamp Kit w/ Hardware 12 to 6 (0.39 to 0.60) 4 to 10 (9.9 to 15.2)                                           SBS75XCLP1-BK          SBS75XCLP1

Small Wire Clamp Kit w/ Hardware 12 to 6 (0.34 to 0.55) 4 to 10 (8.6 to 14.0)                                           SBS75XCLP2-BK          SBS75XCLP2

                                                                                           [ 21.8 ]                               [ 36.4 ]
                                                                                            0.86                                   1.44

                                                                                                                                                       The given wire O.D. information is

                                                                                                                                            [  45.9 ]  an estimate. Cable clamps should
                                                                                                                                               1.81
                                                                                 [ 48.3 ]                               [ 55.5 ]                       be  evaluated         for  performance  with
                                                                                  1.90                                   2.18
                                                                                                                                                       the actual wire to be used.

                                                                                 Clamp hardware requires phillips or flat blade
                                                                                 screwdriver to assemble.

All Data Subject To Change Without Notice                                                                                                                  www.andersonpower.com - 55 -
           Reducing Bushings

           Use with contact part number 1339G2-BK or 1340G1-BK to allow a smaller wire to be used with the connector. Electrical

           c apab ility is derated with smaller wire.

                                                                                                               Dimensions

                                                                                                               - ID -   - Length -

           Contact Barrel Size  Wire Size                  -------- Part Numbers -------- inches mm inches mm

           Minimum Quantity ...................................................... 3,000  1,000 100 .....................................................                Length  ID

           #6 AWG [13.3 mm] #8 AWG [8.4 mm]              -                              5912-BK 5912 0.18 4.57 0.45 11.43

           #6 AWG [13.3 mm] #12- 10 AWG [3.3- 5.3 mm] 5910-BK                              -       5910 0.14 3.56 0.47 11.94

           #6 AWG [13.3 mm] #16- 14 AWG [1.3- 2.1 mm] 5913-BK                              -       5913 0.09 2.29 0.47 11.94                                                   Wire Entrance

           SBS
           - Tooling Information

           Wire Size

                                Power Contact              Pneumatic Bench                                              Number of
                                 Part Number                                                                              Crimps
            AWG        mm                                 Tool                              + Die          + Locator                                      Hand Tool
              #6       13.3          1339G2                                                                                                                 1309G4
              #8        8.4          1339G5                                                  1388G6            1389G9
                     5.3 / 3.3       1339G3                                                                    1389G20
           #10 / 12    13.3          1340G1                1387G1                            1388G7                     Single
              #6        8.4          1340G2                                                  1388G6
              #8     5.3 / 3.3       1340G3
                                                                                             1388G7
           #10 / 12

           Wire Size

SECTION 3                                                                                    Mil Std. Hand                                                 Locator for:

   SBS                         Auxiliary Contact APP Hand Tool w/                              Tool*       Pneumatic                                      TM0001 &

           AWG       mm        Part Number                Integral Locator                  M22520/1-01       Tool* Number of Crimps TP0001

           #12 / 24 2.5 / 0.25 All Crimp Pins              PM1000G1                       O  TM0001         O  TP0001   Single                                   TL0001
                                        All Crimp Sockets                                 R                 R                                              +

                                                                                                                                                                 TL0002

           * TP0001 and TM0001 tools require locators TL0001 for Pins and TL0002 for Sockets.
             NOTE: See website for the most current information.

- 56 - www.andersonpower.com                                                                                                                               All Data Subject To Change Without Notice
SB 50 Connectors
- up to 120 amps

                                                                 Based off the design pioneered by Anderson in 1953,
                                                                 APP's two pole SB connectors set the standard for
                                                                 DC power distribution and battery connections. SB50
                                                                 connectors feature a one piece plastic housing using
                                                                 stainless steel springs to hold low resistance contacts in
                                                                 place. Wires sizes from #16 (1.5 mm) to #6 (13.3 mm)
                                                                 are held in the smallest of the SB series housings.

                                                                  Low Resistance Silver or Tin Plated Copper Contacts
                                                                   Allows UL rated currents up to 120 amps

                                                                  UL Rated for Hot Plugging up to 50 Amps
                                                                   Great for battery or other applications where the ability to
                                                                   interrupt circuits is required

                                                                  Wire, PCB, and Busbar Contacts
                                                                   Allows one connection system to meet multiple needs

| SB50 ORDERING INFORMATION |                                                                                                     SECTION 3

SB50 Standard Housings                                                                                                          SB 50

The smallest SB housings work with wire contacts up to

6 AWG [10 mm] as well as PCB, and busbar contacts.

Genderless design mates with itself. Mechanical keys are

c olor co ded.
                   Voltage

        Color

Description Code ---- Part Numbers ----                                    Bottom View

Minimum Quantity .... 500                  100 ...                                                [ 3.7 ]
                                                                                                 0.14
Yellow  12V 992G5-BK 992G5                                                                     (2) PLC'S

Orange  18V 992G7-BK 992G7                                                                     Material ID
                                                                                               P = Chemical Resistant
Red     24V 992G1-BK 992G1                                       [ 35.1 ]
                                                                  1.38                         [ 6.4 ]
Gray    36V 992-BK                         992                                                 0.25

Blue    48V 992G4-BK 992G4

Green   72V 992G6-BK 992G6

Black   80V 992G2-BK 992G2                                                 [ 22.5 ]  [ 19.1 ]
                                                                            0.89      0.75
NOTE: SB50 Black and Gray housings have the

same keying features and can be intermated.

SB50 Chemical Resistant Housings                                      [ 81.3 ]
                                                                        3.20
Same features as the Standard SB50 but molded in a
                                                                 Mated Length
c hemica l resista nt PBT/ PC blend. Suitable for use to -40C.                                [ 15.9 ]
                   Voltage                                                                      0.63

        Color

Description Code ---- Part Numbers ----

Minimum Quantity .... 500                  100 ...

Red     24V P992G1-BK P992G1

Gray    36V P992-BK P992

Black   80V P992G2-BK P992G2

NOTE: SB50 Black and Gray housings have the

same keying features and can be intermated.

All Data Subject To Change Without Notice                                                      www.andersonpower.com - 57 -
           SB50 Silver Plated Wire Contacts

           Use two silver plated contacts per housing for the best electrical

           performance and durability up to 10,000 mating cycles.

                                                                    Dimensions

                              Mating    Loose Piece                 -A-

           AWG          mm   Force --- Part Numbers --- inches mm

           Minimum Quantity ................... 1,000 100 .........................

           6            13.3  Low       1307-BK 1307                0.22 5.59                                                              A
                                                                                                                  D
           6            13.3  High      5900-BK 5900                0.22 5.59                                   C

           8            8.4   High      5952-Bk 5952                0.19 4.83                                     B

           12 to 10 3.3 to 5.3 Low      5953-BK 5953                0.14 3.56

           12 to 10 3.3 to 5.3 High     5915-BK 5915                0.14 3.56                                                                                                            [ 7.1 ]
                                                                                                                                                                                         0.28

           SB50 Tin Plated Reeled Wire Contacts

           Use two reeled contacts per housing. Reeled contacts are for use with the recommended

           h igh volum e press  and applic ator tooli ng. Rated for up to 1,500 mating cycles.

                                                                    Dimensions

                              Mating       Reeled                   -A-              -B-

           AWG mm            Force - Part Numbers - inches mm inches mm

           Minimum Quantity ...................... 2,000     .................................................                                                          A

           8 to 6 8.4 to 13.3 High         265G5             0.26 6.60 0.36 9.14

           12 to 10 3.3 to 5.3 High        265G6             0.17 4.32 0.29 7.37                                                    [ 32.2 ]            B

                                                                                                                                    1.27

           SB50 Silver Plated Busbar Contacts                                                                                 See Busbar contact drawing on
                                                                                                                               website for further detail.
           Use 2 busbar contacts per housing to provide a quick disconnect input or output
           busbar connection. Busbar contacts are for mating with wire contacts only. Part number                                                              [ 2.0 ]
           75BBS includes lock nuts. Locknuts must be ordered separately for B01956P4.                                                                          0.08
                                                                                                                                                      [ 69.1 ]
                              Mating                                                                                                                    2.72                             [ 17.1 ]
                                                                                                                                                                                          0.68

SECTION 3  Type         Thread Force ----------- Loose Piece Part Numbers -----------

   SB 50  Minimum Quantity ................. 1,000       120            20          10 ...

           Busbar #10-24 High           -                 B01956P4       -           75BBS

           Lock Nut #10-24 -          H1216P8             -         110G54           -

           55A Right Angle Standard Powerclaw PCB Contacts                                                                Top View

           Standard Powerclaw contacts are for use inside a SB50 housing                                       [ 21.6 ] [ 19.05 ]                                            Side View
                                                                                                                 0.85 0.750
           and provide a color coded right angle connection to the PCB.                                                                       [ 22.6 ]     [ 23.7 ]     [x]
                                                                                                                                               0.89         0.93         x
           Description        - Loose Piece Part Numbers -                           [ 8.0 ]
                                                                                     0.32                                                                                                [ 15.6 ]
           Minimum Quantity .... 500                 100 .......                                                                                                                          0.62

           Tin Plated         PC5930T-BK PC5930T

           Silver Plated      PC5930S-BK PC5930S                                     [ 27.4 ]                                                 [ 35.0 ]
                                                                                      1.08                                                    1.380

                                                                                                                                                                           [ 63.6 ]
                                                                                                                                                                            2.51

                                                                                             [ 11.4 ]              [ 3.7 ]          See PCB contact drawing on website for further detail.
                                                                                              0.45               0.14 (2)

           55A Right Angle Mini Powerclaw PCB Contacts                                                               [ 8.1 ]        [ 24.6 ]               [ 12.19 ]
                                                                                                                      0.32           0.97                   0.480
           Right angle Mini Powerclaw contacts can be used on the PCB edge
           without a SB50 housing on the PCB side. A self polarizing design only                               [ 7.6 ]
           allow SB50 wire housings to mate to PCB contacts one way.                                           0.30

           Description        - Loose Piece Part Numbers -                                                       [ 2.42 ]                                               [ 25.4 ]
                                                                                                                  0.095                                                  1.00
           Minimum Quantity .... 1,000               100 .......                                                                              [ 17.5 ]
                                                                                                                     [ 6.10 ]                  0.69                           [ 1.27 ]
           Tin Plated         PC5934T-BK PC5934T                                                                      0.240                                                    0.050

           Silver Plated      PC5934S-BK PC5934S

- 58 - www.andersonpower.com                                                                                                                               All Data Subject To Change Without Notice
55A Vertical Mini Powerclaw PCB Contacts                                                                                  [ 12.2 ]              [ 6.25 ]
                                                                                                                           0.48                  0.246
Vertical Mini Powerclaw contacts save space by not requiring a SB50
housing on the PCB side. The guide housing is required for to provide a                              [ 24.3 ]                                [ 1.27 ]
polarized connection. (See SB50 accessories).                                                        0.96                                   0.050
                                                                                                                                            [ 4.98 ]
Description    - Loose Piece Part Numbers -                                                               [ 9.7 ] [2.32]                    0.196
                                                                                                          0.38 0.091
Minimum Quantity .... 1,500                     100 .........

Tin Plated     PC5933T-BK PC5933T                                                                                         [ 10.29 ]
                                                                                                                           0.405
Silver Plated  PC5933S-BK PC5933S

| SB50 CONNECTOR SPECIFICATIONS |

Electrical                                                               Mechanical

Current Rating Amperes                    UL 1977 CSA                   Wire Size Range                   AWG                       mm

Wire to Wire UL 1977 (6 AWG) 120                  50                                                       16 to 6                   1.3 to 13.3

Wire to PCB UL 1977 (6 AWG) 50                                          

                                                                         Max. Wire Insulation Diameter     in.                       mm

Voltage Rating AC/DC                                                                                       0.440                     11.200

UL 1977                                    600                           

                                                                         Operating Temperature            F                        C

PCB Connector Recommended Voltage                                        Standard                          -4 to 221 -20 to 105

per IEC 60950-1 Table 2L Pollution Degree2                               Chemical Resistant*               -40 to 221 -40 to 105

Mini Vert. Contact                         522                           *Chemical resistant material not available for PCB guide housings

Mini Horiz. Contact                        504

Standard Contact                           950                           

                                                                         Mating Cycles No Load by Plating  Silver (Ag) Tin (Sn)                                   SECTION 3

Dielectric Withstanding Voltage                                          Wire and PCB Contacts             10,000                    1,500                      SB 50

Volts AC                                   2,200                        

                                                                         Avg. Mating / Unmating Force      Lbf.                      N

Avg. Mated Contact Resistance Milliohms                                 Wire to Wire Low Force Contacts   10                        44

1 1/4" of #6 AWG wire                      0.200                         Wire to Wire High Force Contacts  15                        67

PCB Contact to Contact                     0.500                         Standard Powerclaw to Wire        15                        66

                                                                         Mini Powerclaw to Wire            8                         36

UL Hot Plug Current Rating Amperes - 250 cycles at 120V DC               

Wire- wire                                 50A                           PCB Specifications

PCB- wire                                  40A                           Mounting Style                    Plated Through Hole

(Vertical Mini Powerclaw)                                                Max PCB Thickness- in. [mm]       Standard: 0.15 [0.381]

                                                                                                           Mini: 0.25 [0.635]

Materials                                                                Recommended Traces                #8 AWG Cross Section

Housing                                                                  
Standard Plastic Resin
Chem. Resistant Resin                     Polycarbonate                 Min. Contact / Spring Retention Force Lbf.                  N
Contact Retention Spring                  Polycarbonate / PBT blend
                                           Stainless Steel               Wire Housing                      50                        222

                                                                        

                                                                         Min. Creepage / [Clearance] Distance in.                    mm

Housing Flammability Rating                                              Standard Powerclaw                0.374                     9.5

UL94                                       V-0                           Mini Vert. Powerclaw              0.213                     5.4

                                                                         Mini Horz. Powerclaw              0.205                     5.2

Contact                                    Copper Alloy                  Protection
Base                                      Silver
Wire Plating                              Sn or Ag over Ni              Touch Safety with Wire Contacts
PCB Plating
                                                                         IEC 60529             IP10

Contact Termination Methods                Wire Contacts                  Based on: 105C rated or better cable of the largest size, Properly calibrated APP
Crimp                                    Wire and PCB Contacts          recommended tooling, and a 25C ambient temperature. UL rating not to exceed
Hand Solder                               PCB Contacts                   the maximum operating temperature. CSA rating below a 30C temperature rise.
Solder Dip*                               PCB Contacts
Wave Solder*                              Busbar Contacts                Limited by the thermal properties of the connector plastic housing.
Wrench / Socket                                                          Use APP recommended tooling only. Alternate tools may adversely affect the

                                                                          performance of our connectors along with UL and CSA recognition.

All Data Subject To Change Without Notice                                                                                 www.andersonpower.com - 59 -
           | SB50 CONNECTOR TEMPERATURE CHARTS |

                                                          SB50                                                                      SB50
                                    Temperature Rise at Constant Current
                                                                                                                  Derating vs. Ambient Temperature
                             60                                                                        125

           Temperature (C)  50                                                      Temperature (C)
                                                                                                                  100

                             40

                             30                                                                        75

                             20                                                                        50

                             10

                             0 0 10 20 30 40 50 60 70 80 90                                            25
                                                   Amperes Applied                                         0 10 20 30 40 50 60 70 80 90 100

                                                                                                                        Amperes Applied

                                  6 AWG                       8 AWG                                                      6 AWG   8 AWG
                                 10 AWG                      12 AWG                                                     10 AWG  12 AWG

                                                   Mini Powerclaw                                                             Mini Powerclaw
                                    Temperature Rise at Constant Current
                             60                                                                                   Derating vs. Ambient Temperature
                                                                                                       125

           Temperature (C)  50                                                      Temperature (C)
                                                                                                                   100

                             40

                             30                                                                        75

                             20
                                                                                                                    50

                             10

SECTION 3                    0                                                                         25               10 20 30 40 50 60 70 80 90 100110
                                0 10 20 30 40 50 60 70 80 90                                                0                         Amperes Applied
   SB 50                                          Amperes Applied                                                                                SB50

                                                             SB50

           NOTE: Temperature rise charts are based on a 25C ambient temperature. Powerclaw charts are based on #8 AWG
           equivalent copper foil on board side, mated to #6 AWG conductor on wire side.

           | SB Accessories |

           "T" Handle                                                                                                                               (2) Self-tapping
                                                                                                                                                    Screws
           The "T" handle makes mating and unmating the connector easier. The
           non-conductive red plastic material is strong and safe. (2) Self tapping                                                      Handle
           screws are used to secure the handle to the connector housing.

           Description                                       --------- Part Numbers ---------                                                                         Connector
           Minimum Quantity ...............................                                                                                                           Housing
           Red "T" Handle + Hardware Bag
           Hardware Bag (2 Screws)                           1,000        50 ........
           Red "T" Handle Only
           #8 x 5/8" Screw (Order 2 Per Handle)              -            SB50-HDL-RED
           
                                                             -            104G17

                                                             113899P1             -

                                                             H1120P41             -

           Dust Cover

           Prevents dust and dirt from entering the mating interface of

           the connector when unmated. NOTE: Not a Hermetic Seal.

           Description                                       ---- Part Numbers ----

           Minimum Quantity .............................. 500            50 ...                                                                    Slide cover over
                                                                                                                                                    mating end.
           Dust Cover with Lanyard Strap, Red 113890P1 134G1

- 60 - www.andersonpower.com                                                                                                                               All Data Subject To Change Without Notice
Guide Housings for Vertical Mini Powerclaw Contacts                                                               SB50 Connector

Prevents polarity being reversed when a SB50 is mated                                                            Mini-vertical
                                                                                                                  Powerclaw Contacts
to vertical mini Powerclaw contacts.
                                                                                                                                 Guide
Description            ------------ Part Numbers -----------                                                                     Housing

Minimum Quantity ....  1,000                  50 ......                                                                             PCB

Black Guide Housing PC-HSG-SB-BK PC-HSG-SB

Cable Clamps

Durable metal cable clamps securely hold cables to prevent accidental strain or pulls from dislodging

wire or contacts from the housing. Cable clamps are recommended for solder terminated wires.

                                                    Cable Size

                                           AWG or             mm or

Description                                (Inches O.D.) (mm O.D.)             ---- Part Numbers ----

Minimum Quantity ........................................................................................... 500  50 ...

Self Attaching for Discrete Conductor 8 to 6                  10               990-BK                             990

Self Attaching for Discrete Conductor 12 to 10                4 to 6           990G2-BK 990G2

Bolt on for Discrete Conductor             12 to 6            4 to 10          990G1-BK 990G1

Bolt on for Bundled Conductor              (0.320 to 0.450) (4.27 to 11.43) 5905-BK 5905

                                                                                                                                                                          SECTION 3

                                                                                                                                                                        SB 50

                       990                                                       990G1                                                                            5905
                                                                                                                              Bolt on bundled conductors.
Self attaching discrete conductor.                  Bolt on discrete conductor.

The given wire O.D. information is an estimate. Cable clamps should
be evaluated for performance with the actual wire to be used.

Reducing Bushings

Use with contact part number 5900-BK or 1307-BK to allow a smaller wire to be used with the connector.

Electrical capability is derated with smaller wire.

                                                                                                                  Dimensions

                                                                                                                  - ID -  - Length -

Contact Barrel Size Wire Size                       -------- Part Numbers -------- inches mm inches mm

Minimum Quantity ...................................................... 3,000  1,000 100 ...................................................

#6 AWG [13.3 mm] #8 AWG [8.4 mm]                  -                          5912-BK 5912 0.18 4.57 0.45 11.43                              Length  ID

#6 AWG [13.3 mm] #12- 10 AWG [3.3- 5.3 mm] 5910-BK - 5910 0.14 3.56 0.47 11.94

#6 AWG [13.3 mm] #16- 14 AWG [1.3- 2.1 mm] 5913-BK - 5913 0.09 2.29 0.47 11.94

                                                                                                                                                      Wire Entrance

All Data Subject To Change Without Notice                                                                                                     www.andersonpower.com - 61 -
            SB120 Connectors
            - up to 240 Amps

                                                                           Like the other Multipole connectors, the SB120 offers
                                                                           color-coded mechanically keyed housings. Keys can be
                                                                           used to identify and separate different circuits, or prevent
                                                                           users from accidentally cross mating different voltages.
                                                                           Wires sizes from #10 (5.3 mm) to #1 (42.4 mm) are held
                                                                           in the second smallest SB housing.

                                                                            New extended range contacts expand wire size up
                                                                             to #1 AWG (42.4 mm)
                                                                             Allows UL rated currents up to 240 amps

                                                                            Chemical resistant housing option
                                                                             Extends temperature range down to -40C, while offering
                                                                             enhanced UV and chemical resistance

                                                                            Panel mounting grooves
                                                                             With use of mounting clamps, can be easily mounted through panels

            | SB120 ORDERING INFORMATION |

SECTION 3   SB120 Standard Housings                                                          Bottom View

   SB 120  The second to smallest SB housings work with wire                                [ 63.5 ]
            contacts up to 1 AWG [35 mm] as well as busbar                                    2.50
            contacts. Genderless design mates with itself.                                              [ 37.6 ]
            Mechanical keys are color coded.                                                              1.48

                  Voltage

                  Color                                                              [ 2.5 ]
                                                                                     0.10
            Description Code ----- Part Numbers -----

            Minimum Quantity ...... 250   50 ....                                                                   [ 5.1 ]
                                                                                                                     0.20
            Red   24V 6810G3-BK 6810G3                                                                            (2) PLC'S

            Gray  36V 6810G1-BK 6810G1                                                                              Material ID
                                                                                                                    P = Chemical Resistant
            Blue  48V 6810G2-BK 6810G2                                     [ 46.4 ]
                                                                            1.83                                        [ 8.6 ]
                                                                                                                         0.34
            SB120 Chemical Resistant (CR) Housings                                           [ 19.1 ]
                                                                                               0.75                          [ 20.6 ]
            Same features as the Standard SB120 but molded in a chemical                                                      0.81
                                                                                                       [ 104.6 ]
            r esista nt PBT/ PC blend. Suitable for use to -40C.                                        4.12

                  Voltage                                                                        Mated Length

                  Color

            Description Code ------- Part Numbers -------

            Minimum Quantity ......  250  50 .....

            Red   24V P6810G3-BK P6810G3

            Gray  36V P6810G1-BK P6810G1

- 62 - www.andersonpower.com                                                                                      All Data Subject To Change Without Notice
SB120 Silver Plated Wire Contacts

Silver plated contacts offer superior electrical performance and durability up to 10,000 mating cycles.

                                                                       Dimensions

            Mating                                                     -A-         -B-

AWG mm     Force ------- Loose Piece Part Numbers -------      inches mm inches mm

Minimum Quantity ...........  600          500         50    ...............................................

1     42.4  Low               1323G1-BK    -        1323G1      0.47 11.94 0.39 9.91

2     33.6  Low               -            6811G6-BK 6811G6     0.44 11.18 0.22 5.59

2     33.6  High              -            1319-BK  1319        0.44 11.18 0.22 5.59

4     21.1  Low               -            6811G5-BK 6811G5     0.44 11.18 0.30 7.62                          [ 21.3 ]  [ 50.8 ]
                                                                                                               0.84       2.0
4     21.1  High              -            1319G4-BK 1319G4     0.44 11.18 0.30 7.62                            B

6     13.3  Low               -            6811G4-BK 6811G4     0.44 11.18 0.34 8.64                              A

6     13.3  High              -            1319G6-BK 1319G6     0.44 11.18 0.34 8.64

                                                                                                                                                                                   [ 10.4 ]
                                                                                                                                                                                    0.41

SB120 Silver Plated Busbar Contacts                                                                                                                                                 SECTION 3

Use 2 busbar contacts per housing to provide a quick disconnect input or                                                                                                           SB 120
output busbar connection. Busbar contacts are for mating with wire contacts only.
Part number 120BBS includes lock nuts. Locknuts must be ordered separately
for B01997P1.

            Mating

Type  Thread Force ------------ Loose Piece Part Numbers ------------

Minimum Quantity ............... 1,000     300 20            10 ....                                          See Busbar contact drawing on
                                                                                                              website for further detail.
Busbar #10-24 High            -            B01997P1 -      120BBS
                                                                                                                                              [ 77.0 ]
Lock Nut #10-24 -             H1216P8      - 110G54          -                                                                                  3.03             #10 - 24 THD

                                                                                                                                 [ 9.5 ]                                 [ 11.1 ]
                                                                                                                                  0.38                                     0.44

                                                                                                                                                        [ 2.5 ]
                                                                                                                                                        0.10

All Data Subject To Change Without Notice                                                                               www.andersonpower.com - 63 -
            | SB120 CONNECTOR SPECIFICATIONS |

            Electrical                                                                                             Mechanical

            Current Rating Amperes                  UL 1977              CSA                                      Wire Size Range                     AWG          mm
                                                                          130                                                                                       5.3 - 42.4
            Wire to Wire (1 AWG)                     240                                                           Wire Contacts with Bushings         10 - 1
                                                                                                                                                                    mm
            Wire to Busbar (2 AWG)                   120                                                                                                            15.240

                                                                                                                   Max. Wire Insulation Diameter       in.          C
                                                                                                                                                                    -20 to 105
            Voltage Rating AC/DC                                                                                                                       0.600        -40 to 105

            UL 1977                                  600                                                                                                            N
                                                                                                                                                                    89
                                                                                                                   Operating Temperature              F

            Dielectric Withstanding Voltage                                                                        Standard                            -4 to 221

            Volts AC                                 2,200                                                         Chemical Resistant*                 -40 to 221

                                                                                                                  

            Avg. Mated Contact Resistance Milliohms                                                               Mating Cycles No Load by Plating    Silver (Ag)

            5 1/2" of #2 AWG wire                    0.136                                                         Wire and Busbar Contacts            10,000

                                                                                                                  

            Hot Plug Current Rating Amperes - Wire & Busbar                                                        Avg. Mating / Unmating Force        Lbf.

            250 cycles at 120V DC                    60A                                                           Wire to Wire                        20

                                                                                                                  

            Materials                                                                                              Min. Contact / Spring Retention Force

            Housing                                                                                                lbf                                 75
             Standard Plastic Resin
             Chem. Resistant Resin       Polycarbonate                                                             N                                   333.6
             Contact Retention Spring    Polycarbonate / PBT blend
                                         Stainless Steel                                                           Protection

                                                                                                                   Touch Safety with Wire Contacts

            Housing Flammability Rating                                                                            IEC 60529            IP10

            UL94                         V-0

            Wire & Busbar Contacts       Copper Alloy
             Base                        Silver
             Plating

SECTION 3   Contact Termination Methods  Wire Contacts
             Crimp                      Wire Contacts
   SB 120   Hand Solder                 Busbar Contacts Only
             Wrench / Socket

             Based on: 105C rated or better cable of the largest size, Properly calibrated APP recommended tooling, and a 25C ambient temperature. UL rating not to exceed
             the maximum operating temperature. CSA rating below a 30C temperature rise.

             Limited by the thermal properties of the connector plastic housing.
             Use APP recommended tooling only. Alternate tools may adversely affect the performance of our connectors along with UL and CSA recognition.

            | SB120 CONNECTOR TEMPERATURE CHARTS |

                                                        SB120                                                                SB120
                                    Temperature Rise at Constant Current
                                                                                                            Derating vs. Ambient Temperature
                              60                                                                 125

            Temperature (C)  50                                               Temperature (C)
                                                                                                              100

                              40

                              30                                                                 75

                              20
                                                                                                               50

                              10

                              0                                                                  25
                                0 25 50 75 100 125 150 175 200 225                                    0 25 50 75 100 125 150 175 200 225 250

                                  Amperes Applied                                                                             Amperes Applied

                                  1 AWG       2 AWG                                                                     1 AWG                   2 AWG

                                  4 AWG       6 AWG                                                                     4 AWG                   6 AWG

            NOTE: Temperature rise charts are based on a 25C ambient temperature.

- 64 - www.andersonpower.com                                                                                                                                   All Data Subject To Change Without Notice