器件型号:84874130
器件类别:热门应用    机电_工控_自动化   
文件大小:1675.05KB,共4页
厂商名称:Crouzet
标准:
下载文档

器件描述

controllers ht81 24 240vac/DC PT

参数

Manufacturer: Crouzet
Product Category: Controllers
RoHS: Yes
Analog / Digital: Analog
Type: Temperature Controller
Display Type: LED Display
Supply Voltage: 24 V to 240 V
Mounting: DIN Rail
Control Method: Stored program control
Size: 90 mm x 60 mm x 35 mm
Brand: Crouzet Control
Features: Independent setting of high and low thresholds
Number of Inputs: 1
Number of Outputs: 2
Output Type: 2 x SPST NO
Series: HWT81

84874130器件文档内容

23/06/2014                                                                                                                                               www.crouzet.com

Temperature control relay for lift service rooms - according to EN81 - 35 mm HWT81 Part number 84874130

                                               Control relay designed to monitor the temperature in lift machine rooms in accordance with standard EN81

                                               PT100 input

                                               Adjustable control between 5 °C and 40 °C

                                               Independent setting of high and low thresholds

                                               Built-in phase control option

Part numbers

              Type          Function                                                                                             Nominal voltage (V)     3-phase control

84874130      HWT81         Under/Overtemperature window mode + phase sequence and failure                                       24 →240 V AC/DC         3 x 208 →480 V AC

Specifications

Supply

Supply voltage Un                                           24 V →240 V AC/DC

Voltage supply tolerance                                    -15 %, + 10 % AC

                                                            -10 %, +10 % DC

Operating range                                             20,4 V →264 V AC

                                                            21,6 V →264 V DC

Polarity with DC voltage                                    No

AC supply voltage frequency                                 50 / 60 Hz ±10 %

Power consumption at Un                                     3.5 VA in AC/0.6 W in DC

Immunity from micro power cuts                              10 ms

Inputs and measuring circuit

Low temperature measurement selection                       -1 °C, 1 °C, 3 °C, 5 °C, 7 °C, 9 °C, 11 °C

High temperature measurement selection                      34 °C, 36 °C, 38 °C, 40 °C, 42 °C, 44 °C, 46 °C

Temperature measurement input resistance                    1330 Ω

Fixed hysteresis                                            2 °C

Display precision                                           ±2%

Max. length of Pt100 probe cables                           10 m

Timing

Delay on thresold crossing                                  1 →10 s

Display precision                                           0, + 10 %

Reset time                                                  8s

Delay on pick-up                                            200 ms

Maximum response time on disappearance of fault             3.5 s for a temperature fault

                                                            500 ms for a phase fault

Output

Type of contacts                                            No cadmium

Maximum breaking voltage                                    250 V AC/DC

Max. breaking current                                       5 A AC/DC

Min. breaking current                                       10 mA / 5 V DC

Electrical life (number of operations)                      1 x 104

Breaking capacity (resistive)                               1250 VA AC

Maximum rate                                                360 operations/hour at full load

Operating categories acc. to IEC/EN 60947-5-1               AC 12, AC 13, AC 14, AC 15, DC    12,       DC          13,  DC  14

Mechanical life (operations)                                30 x 106

Insulation

Insulation coordination (IEC/EN 60664-1)                    Overvoltage category III : degree of pollution 3

Rated impulse withstand voltage (IEC/EN 60664-1)            4 kV (1,2 / 50 μs)

Dielectric strength (IEC/EN 60664-1)                        2 kV AC 50 Hz 1 min.

Insulation resistance (IEC/EN 60664-1)                      > 100 MΩ - 500 V DC

General characteristics

Display power supply                                        Green LED

Temperature indication                                      Yellow LED (HWT81)

"Phase" indication                                          Yellow LED (HWT81)

High threshold relay                                        Yellow LED (HT81, HT81-2)

Low threshold relay                                         Yellow LED (HT81, HT81-2)

Casing                                                      35 mm

Mounting                                                    On 35 mm symmetrical DIN rail, IEC/EN 60715

Mounting position                                           All positions

Unless otherwise specified, the characteristics given are  applicable to all or part of the product range selected
23/06/2014                                                                                                                                                              www.crouzet.com

Material : enclosure plastic type VO to UL94 standard  Incandescent wire test according to IEC 60695-2-11          & NF       EN  60695-2-11

Protection (IEC/EN 60529)                              Terminal block : IP 20

                                                       IP 30 casing

Weight                                                 121 g

Connecting capacity IEC/EN 60947-1                     Rigid : 1 x 42 - 2 x 2.52 mm2

                                                       1 x 11 AWG - 2 x 14 AWG

                                                       Flexible with ferrules : 1 x 2.52 - 2 x 1.52 mm2

                                                       1 x 14 AWG - 2 x 16 AWG

Max. tightening torques IEC/EN 60947-1                 0,6 →1 Nm / 5,3 →8,8 Lbf.In

Operating temperature IEC/EN 60068-2                   -20 →+50 °C

Storage temperature IEC/EN 60068-2                     -40 →+70 °C

Humidity IEC/EN 60068-2-30                             2 x 24 hr cycle 95 % RH max. without condensation           55 °C

Vibrations according to IEC/EN60068-2-6                10 →150 Hz, A = 0.035 mm

Shocks IEC/EN 60068-2-6                                5g

Standards

Marking                                                CE (LVD) 73/23/EEC - EMC 89/336/EEC

Product standard                                       NF EN 60255-6 / IEC 60255-6 / UL 508 / CSA C22.2 N°14 / EN 81-1

Electromagnetic compatibility                          Immunity EN 61000-6-2/IEC 61000-6-2

                                                       Emission EN 61000-6-4/EN 61000-6-3

                                                       IEC 61000-6-4/IEC 61000-6-3

                                                       Emission EN 55022 class B

Certifications                                         UL, CSA, GL

Conformity with environmental directives               RoHS, WEEE

Inputs and measuring circuit

Phase control voltage range                            208 V →480 V (-15 % / +10 %) *

Phase failure detection with regeneration              > 30 % of the average of the 3 phases

Frequency of measured signal                           50 →60 Hz ± 1 Hz

Relay drop-out voltage (phase failure)                 70 %

3-phase input resistors                                600 KΩ

Timing

Maximum response time in the event of a 3-phase fault  500 ms

(ms)

Output

Type of output                                         2 single pole NO relay

Insulation

Galvanic isolation of power supply/measurement         Yes, between power supply and PT100 (transformer)

                                                       Yes, between power supply and output (transformer and relay)

                                                       Yes, between power supply and 3-phase network (transformer) Yes, between 3-phase network               and       output (relay)

                                                       No, between 3-phase network and PT100 (leakage current limited by several high-value resistors)

                                                       Yes, between PT 100 and output (relay)

Nominal insulation voltage                             400 V

Comments

Accessories

Description                                                                                                                                                   Code

Removable sealable cover for 35 mm casing                                                                                                                     84800001

Principles

Overview

Temperature control relays for lift machine rooms are designed for monitoring the temperature between 5            °C and 40  °C according to standard EN81.

Principles

Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
23/06/2014                                                                                                                                                                    www.crouzet.com

HWT81 operating principle :

As long as the temperature controlled by the PT100 stays between the two preset thresholds on the front face, the temperature relay is closed.

When the temperature exceeds one of the preset thresholds on the front face (upper or lower threshold), the preset time delay on the front face (Tt) is activated. The yellow temperature LED (R1)

flashes. At the end of the time delay, if the temperature still exceeds the preset threshold, the output relay opens and the yellow LED is extinguished.

The output relay R1 closes instantaneously when the temperature returns within the window of the two preset thresholds on the front face plus or minus the fixed hysteresis.

The unit also monitors correct sequencing of phases L1, L2 and L3 of the 3-phase network and the total phase failure in the event of phase regeneration (<70 %).

After a time delay on pick-up (t) and as long as the presence and sequence of the phases are correct, relay R2 and the R2 "phase" LED are active. When a fault appears, the "phase" relay opens

and the R2 "phase" LED is extinguished instantly (response time from the appearance of a fault).

On disappearance of the fault, both relay R2 and the phase control LED are activated (response time from the disappearance of a fault). See "Phase failure and phase sequence" curve on page

If the PT100 probe is wired incorrectly (missing or short-circuited), output relay R1 opens and the yellow R1 LED flashes.

No           Legend

             High threshold

             Low threshold

             Hysteresis

             Monitored temperature

             Threshold crossing delay adjustable on front face (Tt)

Dimensions (mm)

mm

Connections

Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
23/06/2014                                                                                                            www.crouzet.com

HWT81

No          Legend

            Fusible ultra rapide 1 A ou coupe circuit

Product  adaptations

                      Customisable colours and labels

                      Fixed threshold in the generic measurement  range

                      Fixed or adjustable time delay

                      Adjustable fixed hysteresis

Unless otherwise specified, the characteristics given are applicable to all or part of the  product  range  selected
This datasheet has been downloaded from:

datasheet.eeworld.com.cn

Free Download

Daily Updated Database

100% Free Datasheet Search Site

100% Free IC Replacement Search Site

Convenient Electronic Dictionary

Fast Search System

www.EEworld.com.cn

All Datasheets Cannot Be Modified Without Permission

               Copyright © Each Manufacturing Company

小广播

84874130器件购买:

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved