电子工程世界电子工程世界电子工程世界

产品描述

搜索

80PK-3A

器件型号:80PK-3A
器件类别:热门应用    测试测量   
文件大小:124206.29KB,共72页
厂商名称:Fluke
标准:
下载文档

器件描述

environmental test equipment probe surface

参数
Manufacturer: Fluke
Product Category: Environmental Test Equipment
RoHS: Yes
Brand: Fluke
Equipment Type: Surface Probe
Measures: Temperature
Factory Pack Quantity: 1
Part # Aliases: 874610

80PK-3A器件文档内容

Test Tools Catalog

Volume one, 2007

                        Fluke Ti20

                        Thermal Imager

                        Fluke 975

                        AirMeter™

                        Fluke 1587

                        Insulation Multimeter

Find it. Fix it. Fast.  Fluke 199C

                        Color ScopeMeter®
                                          Test Tools Catalog

                                             Volume 37, 2007

                                                                                              Contents                                                  Contact us:

                                                                                                                                                        United States

                                                                                                                                                        General product and sales

   Fluke tools for:                                                          Process Calibration Tools                                                  information: 1-888-44-FLUKE

   Commercial Electricians...................................... 3           Process Tools Selection Guide.......................... 37                 Fluke Thermal Imagers:

   Industrial Electricians.......................................... 4       744, 743B, 741B Documenting Process                                        1-800-760-4620 (U.S. only) all

   HVAC/IAQ Technicians......................................... 5           Calibrators........................................................... 38  other regions 1-425-446-4620

   Online resource centers................................... 6              726, 725 Precision Multifunction Process                                   Service and calibration:

   Fluke test tool information.............................. 7               Calibrators........................................................... 39  1-800-993-5853

   Safety and its importance................................ 8               724, 714, 712 Temperature Calibrators............40                        Parts: 1-800-526-4731

   Service, repair, and calibration..................... 9                   718, 717 Pressure Calibrator, 700 Series                                   Canada

   Digital Multimeters                                                       Pressure Modules................................................ 41        General product and sales

   Multimeter Selection Guide............................... 10              715, 707, 705 Loop Calibrators.........................42                  information: 1-800-36-FLUKE

                                                                             789, 787 Process Meters...................................43               Service, parts and calibration:

   Faster, Safer Multimeters................................... 11           771 Milliamp Process Clamp Meter..................44                       1-800-36-FLUKE

   189 Logging Multimeter.................................... 12                                                                                        canada@fluke.com

   FlukeView Forms® Software............................. 13                 9102S, 9100S Handheld Drywell                                              Australia

   87V Industrial Multimeter................................. 14             Temperature Calibrators....................................44              General product and sales

   179 Digital Multimeter....................................... 15          Intrinsically Safe Products                                                information: (2) 8850-3333

   Family of True-rms Digital Multimeters........... 16                      707Ex, 718Ex, 725Ex, 700PEx, 574-NI,                                       Parts: (2) 8850-3333

                                                                             68IS, 87V Ex........................................................45     Service and calibration:

   117 and 115 True-rms Digital Multimeters.......17                                                                                                    (2) 9771-9300

   116 and 114 True-rms Digital Multimeters..... 18                          Thermal Imagers                                                            Singapore

   77-IV and 73-III Digital Multimeters............... 19                    Ti40/Ti50 Series IR FlexCam®                                               General product and sales

   27 Waterproof Multimeter................................. 19              Thermal Imagers...........................................46-47            information: 6738-5655

   88V Automotive Multimeter..............................20                 Ti20 Thermal Imager.........................................48             info.asean@fluke.com

   8845A/8846A 6.5 Digit Precision                                           Ti30™ Thermal Imager.......................................49              Service, parts and calibration:

   Multimeters.......................................................... 21  TiR4, TiR3, TiR2 IR FlexCam™                                               6737-2922

                                                                             Thermal Imagers and IR InSight XS,                                         service.asean@fluke.com

   Electrical Testers                                                        XST Thermal Imagers.........................................50             Japan

   T3 and T5 Electrical Testers, VoltAlert™..........22                                                                                                 General product and sales

   9040 Rotary Field Indicator..............................22               Thermometers                                                               information: +81-3-3434-0180

                                                                             570 Series Infrared Thermometers.................. 51                      Service, parts and calibration:

   Earth Ground Testers                                                      54 Series II Contact Thermometers.................52                       +81-3-3434-0188

   1625 and 1623 Geo Earth Ground Testers.....23                             561 HVACPro Thermometer..............................52                    Other countries: 1+(425) 446-5500

   1630 Earth Ground Clamp Meter,                                            60 Series Infrared Thermometers....................53

   Handy Geo Earth Ground Tester.......................24

   Power Quality Analyzers                                                   HVAC/Indoor Air Quality Tools

   430 Series Power Quality Analyzers...............25                       975 AirMeter,™ 902 True-rms

   43B Power Quality Analyzer.............................26                 HVAC Clamp Meter.............................................54

   1760 Power Quality Recorder, 1650 RPM                                     971 Temperature Humidity Meter,

   Power Recorder.................................................. 27       983 Particle Counter..........................................55

   1740 Series Three-Phase PQ Loggers,                                       ScopeMeter® Test Tools

   VR101S Voltage Event Recorder System.........28                           ScopeMeter Test Tools Selection Guide...........56                         Application

   1735 Three-Phase Power Logger,                                            124 Industrial ScopeMeter Test Tools.............. 57                      segment key

   Norma 4/5000 Power Analyzers......................29                      190 Series Color ScopeMeter Test Tools..........58                         To help you better identify the

   Clamp Meters                                                              Fluke ScopeMeter Accessories..........................59                   right product for your job, you

   Fluke 345 and LH1050, LH1060                                              Accessories                                                                will find the applicable icons

   Power Clamp Meters..........................................30                                                                                       located on the outside edge of

                                                                             Accessory Selection Guide................................60                each product page.

   Fluke 360 and LH41 Current Clamp Meters,                                  Accessory Sets and Kits..................................... 61

   LH2015 True-rms Clamp Meter........................ 31                    SureGrip™ Accessories.......................................62

   Better Clamp Meters from Fluke.......................32                   Accessories for Electronic and Automotive

   330 and 320 Series Clamp Meters..................33                       Applications and High Voltage Probes............63

   902 True-rms HVAC Clamp Meter....................54                       Lights, Software and Specialty

   Insulation Testers and MegOhmMeters                                       Accessories................................................... 64-65

   1550B and 1520 Megohmmeters.....................34                        Current Clamps.............................................66-67

   1587 and 1577 Insulation Multimeters............35                        Temperature Accessories............................ 68-69

   1507 and 1503 Insulation Testers....................36                    Cases, Holsters and Fuses........................... 70-71

                                                                             What’s new from Fluke....................back cover


                                           Fluke test tools to

              help you get the job done

            Fluke tools for commercial electricians                           Legend

                                                                                        Power Distribution Center

                                                                                        Heat Exchanger

                                                                                        HVAC Blower

                                                                                        Drive Control

                                                                                        Motor and Motor Control Center

                                                                                        Electrical

              • • • •• •

                               • • • •• •

Fluke 1AC II VoltAlert Voltage             Fluke 116 Digital Multimeter    Fluke 62 Mini IR

Detector                                                                   Thermometer

Best suited for:                           Best suited for:                Best suited for:

•  Non-contact voltage                     •  Measures volts, ohms,        •  Surface temperature

   detection on electrical circuits           capacitance and                 readings

•  Detecting voltage before work begins       temperature                  •  Finding heating and

See page 22 for details                    •  Resistance and continuity       ventilation problems

                                           •  600 V ac and dc              •  Non-contact monitoring

                                              measurement range               of electrical motors and

                                           See page 18 for details            panels

                                                                           See page 53 for details

Fluke T5 Voltage, Continuity               Fluke 322 Clamp Meter           Fluke 87V Industrial True-rms

and Current Tester                                                         Multimeter w/temp

Best suited for:                           Best suited for:                Best suited for:

•  Measure loads on a branch               •  Verify the presence of       •  VSD motor drive

   circuit at a service level                 load current, ac/dc voltage     installation and

•  Measure the load side                      and continuity                  troubleshooting

   voltage of a circuit breaker            •  Current measurements up to   •  Accurate frequency and

   or fuse                                    400 A in tight cable            voltage measurements

•  Map outlets to breakers                    compartments                    on motor drives and

•  Check individual voltages               •  Higher resolution for           in electrically noisy

   (either ac or dc)                          loads below 40 A                environments

•  Determine resistances up to             See page 33 for details         •  Built-in thermometer

   1000 ohms                                                                  for temperature

•  Check circuit continuity                                                   measurements

See page 22 for details                                                    •  CAT III 1000 V rated to protect against

                                                                              high voltage transients up to 8 kV

                                                                           See page 14 for details

                                                                                                                        
                                  Fluke test tools to

                 help you get the job done

                      Fluke tools for industrial electricians                                      Legend

                                                                                                           Pumps

                                                                                                           Drive Control

                                                                                                           Blowers

                                                                                                           Motors

                                                    • • • •• •

                      • • • •• •

   Front line troubleshooting tools

   Fluke 87V Industrial True-rms                 Fluke 1587 Insulation                          Fluke 337 AC/DC True-rms

   Multimeter w/temp                             Multimeters                                    Clamp Meter

   Best suited for: VSD motor                    Best suited for: Work on                       Best suited for: Measure inrush

   drive installation and                        motors, generators, cables or                  current on electric motor startup

   troubleshooting.                              switch-gear.                                   and electric motor testing and

   Features:                                     Features:                                      troubleshooting

   •  Accurate frequency and                     •  Measuring insulation test                   Features:

      voltage measurements                          voltages to 1000 V                          •  Inrush current measurements

      on motor drives and                        •  Prevents insulation test if                    to measure start up current

      in electrically noisy                         voltage > 30 V is detected                     on electric motors

      environments                                  for added user protection                   •  Frequency measurements to

   •  Built-in thermometer for                   •  Filter for motor drive                         help track down power

      temperature measurements                      measurements                                   quality problems

   See page 13 for details                       See page 35 for details                        See page 33 for details

   Preventive and predictive maintenance

   Fluke 434 Three-Phase PQ                      Fluke 576 Photographic IR                      Fluke Ti20 Thermal

   Analyzer                                      Thermometer                                    Imager

   Best suited for: Trouble-                     Best suited for: Measuring                     Best suited for: Displaying

   shooting and preventing                       surface temperatures, quickly                  a visual image of surface

   problems in power distri-                     locating lubrication problems,                 temperatures to easily and

   bution systems.                               overloads, short-circuits or                   safely identify potential

   Features:                                     misaligned and overheated                      problems.

   •  Simultaneously measure                     equipment.                                     For use on:

      voltage and current on all                 Features:                                      •  Electrical power distribu-

      three phases and neutral                   •  Last ten temperature                           tion systems

   •  High-resolution color screen simplifies       readings displayed on                       •  Electro-mechanical equipment

      operation                                     bar graph for easy reference                •  Process instrumentation

   •  Tough enough for industrial environments,  •  Customizable log names, alarms and          •  Facility maintenance

      easy to carry, works for seven hours per      emissivity values for more efficient, less  See page 48 for details

      battery charge                                error-prone predictive maintenance

   See page 25 for details                          routes

                                                See page 51 for details
                               Fluke test tools to

               help you get the job done

                  Fluke tools for HVAC/IAQ technicians                  Legend

                                                                              Indoor Air Comfort

                                                                              Superheat and Subcooling

                                                                              Electrical

                                                                              Motors/Pumps/Compressors

                                                                              Building Diagnostics

                                                                              Filtration and Ventilation

                                                                              Furnace

                               000124

Fluke 975 AirMeter™                    Fluke 983 Particle Counter    Fluke 116 Digital Multimeter

Best suited for:                       Best suited for:              Best suited for:

Optimizing HVAC ventilation            Troubleshooting and           Troubleshooting HVAC

settings for ASHRAE 62                 maintaining indoor            equipment and flame

recommendations                        air quality                   sensors

•  Simultaneously measures,            •  Measures particle size,    •  Thermometer and

   logs and displays tempera-             temperature, and relative     microamps

   ture, humidity, velocity,              humidity                   •  Volts ac/dc, resistance,

   CO2 and CO                          •  Data logging and six-         diode, continuity, and

See page 54 for details                   channel particle size         Min/Max/Avg

                                          display                    See page 18 for details

                                       See page 55 for details

Fluke 902 True-rms                     Fluke 561 HVACPro IR          Fluke IR Insight XS/XST

HVAC Clamp Meter                       Thermometer                   Thermal Imagers

Best suited for: HVAC                  Best suited for: Measuring    Best suited for:

system diagnosis and repair            hot, moving, electrical       Quick, accurate building

•  Capacitance and true-rms            energized objects             diagnostic surveys

•  DC current to 200 µA                •  Contact and non-contact    •  High resolution

•  Contact temperature                    measurement                   images and display

See page 54 for details                •  Compatible with            •  Industry -leading

                                          standard type-K               thermal sensitivity

                                          thermocouple               •  Simple, one-button

                                       •  Includes Velcro® pipe         operation

                                          probe                      See page 50 for details

                                       See page 52 for details

                                                                                                          
              Online resource centers

                                                 Test tool applications                         Solve more

                                                                                                problems with

                                                                                                Fluke Tools

   Electrical Resource Center                    HVAC/IAQ Resource Center                       Fluke is more than digital

   www.fluke.com/electrical_resource_ctr         www.fluke.com/IAQ                              multimeters. These days, Fluke

   Product demos, software downloads, earth      FAQs, white papers, case studies and           offers the ultimate go-everywhere

   ground education, application notes, train-   application notes, downloads, and              DMM as well as specialized tools

   ing and events information.                   product demos.                                 for electrical, industrial, HVAC, and

                                                                                                electronic applications.

                                                                                                Increasingly, technicians are

                                                                                                using their Fluke tools together,

                                                                                                in a one-two troubleshooting

                                                                                                combination.

                                                                                                Use a thermal imager to find a

                                                                                                problem, then use a DMM, clamp

                                                                                                meter, or power quality analyzer to

                                                                                                fix it.

                                                                                                Use a power logger to check

                                                                                                power usage, use an AirMeter to

                                                                                                optimize the HVAC system, and then

                                                                                                log power again to see the impact of

                                                                                                your adjustments.

                                                                                                The online resource centers on

                                                                                                this page can help you find the right

                                                                                                tools for your applications, learn

                                                                                                how to use them, and get to work.

                                                                                                Your site-specific knowledge plus

   Plant Maintenance                             Thermal Imaging                                Fluke tools makes for an impressive

   Resource Center                               Resource Center                                troubleshooting team.

   www.fluke.com/plant_resource_ctr              www.fluke.com/thermal_resource                 Plus, the new generation of Fluke

   ROI calculator, PDM program, maintenance      Online product selection guide, product        tools is smaller, lighter, and easier

   techniques, tool profiles, common culprits.   information, application notes, software       to use than ever. They meet higher

                                                                                                safety standards. They download to

                                                                                                reports. And they’re as reliable and

                                                                                                tough as ever.

                                                                                                By offering a system of tools that

                                                                                                work together, Fluke aims to help

                                                                                                you solve more problems, faster and

                                                                                                better, no matter where you work.

                                                 Building Diagnostics                           Utilities Resource Center

                                                 Resource Center                                www.fluke.com/utilities_resource_ctr

                                                 www.fluke.com/buildings                        Training and events information, product

                                                 Image gallery, application notes, and          demos, specialized technical support,

   Biomedical Resource Center                    expert tips on using thermography to           application notes, and power quality,

   www.fluke.com/biomed_resource_ctr             identify structural, thermal, moisture, and    thermography and earth ground infor-

   Product news and information, catalog,        air leakage problems in buildings.             mation for utilities.

   trade-up program, and tradeshow

   schedule.                                     Precision Measurement and

                                                 Calibration Resource Center

   Electronics Resource Center                   www.fluke.com/precision_resource_ctr

   www.fluke.com/electronics_resource_ctr        New product information, e-news bulletins,

   Tips from the field, product demos, applica-  total solutions newsletter, industry links,

   tion notes, and product showcase.             users community, used certified equipment,

                                                 technical papers and application notes.

   Intrinsic Safety Resource Center              Process Control

   www.fluke.com/ex

   Standards explanations, industry applica-     Resource Center

   tions, guidelines, and product information.   www.fluke.com/process_resource_ctr

                                                 Process calibration glossary, industry infor-

                                                 mation, ROI calculator, application notes,

                                                 and product demos.

  Online Resource Centers
                                                              Fluke...

            more than just tools

                                            Test tool information                      Fluke News

                                                                                       www.fluke.com/flukenews

                                                                                       Fluke News is published two times

Since 1949 the Fluke Corporation has been dedicated to the design                      a year with new tips, tools and

and manufacturing of innovative test and measurement instruments.                      articles in each issue.

Fluke also leads the way in providing programs, training and                           Fluke Electrical News

resources that help you stay at the forefront of your profession.                      For electrical

                                                                                       contractors or

                                                                                       electricians

FlukePlus                                   Electrical Measure-                        working in

Tool Info Online                            ment Safety Program                        residential,

www.fluke.com/flukeplus                     www.fluke.com/safety                       commercial,

                                                                                       or industrial

FlukePlus is a website for test tool users  Get a free safety video, a summary of      environments.

who want to learn more. Sign up and get:    safety standards and helpful articles on

•  Product tips and “how to” articles       safe electrical measurement practices.

•  Previews of the newest Fluke tools       (Available only in the U.S.)

•  Special offers and promotions

•  Direct connection to Fluke technical

   support

                                                                                       Fluke Plant News

                                                                                       For electricians,

                                                                                       electrical

                                                                                       supervisors,

                                                                                       field service

                                                                                       technicians,

                                                                                       plant

                                                                                       technicians

                                                                                       and process

                                                                                       engineers

                                            Test Tool Users                            maintaining

                                                                                       industrial

                                            Online Community                           equipment in

                                            www.fluke.com/community                    the field or

                                            See what other test tool users are saying  plant.

                                            and get your questions answered, fast!

                                            The Test Tool Community online bulletin    Fluke Electronics  News

                                            board is free and open to everyone.        For electronics

                                                                                       or electrical

                                                                                       engineers who

Fluke Education                                                                        use DMMs,

                                                                                       benchtop

Partnership Program                                                                    meters, and

www.fluke.com/education                                                                oscilloscopes

We’ve teamed up with colleges, trade,                                                  in prototyping,

technical, vocational schools, and appren-                                             design and

ticeship programs to bring the latest                                                  field evaluation

application information and tools into the                                             situations.

classroom. Currently available in USA,

Canada, Brunei, Burma, India, Indonesia,

Laos, Malaysia, Philippines, Singapore,

Taiwan, Thailand and Vietnam.

                                            Application Notes                          Fluke HVAC/IAQ News

                                                                                       All-new articles

                                            www.fluke.com/appnotes                     about tools,

                                            Fluke has a                                measuring

                                            complete library                           practices,

                                            of applica-                                and business

                                            tion notes and                             opportunities

                                            white papers on                            for HVAC and

                                            topics ranging                             Indoor Air

                                            from predictive                            Quality (IAQ)

                                            maintenance to                             professionals.

                                            maintaining

                                            motors and

                                            drives to

                                            automotive

                                            troubleshooting

                                            and more.

                                                                                       Fluke Test Tool Information        
                                                  Safety and You

                                            Why is safety important?

                                                      Why should you care?

                                                                                                                          Underwriters

                                                                                                                          Laboratories (UL)

   Between five and ten times on any given

   day, arc flash explosions, sufficient to send

   a victim to a special burn center, take place

   in the U.S. These incidents and other less                                                                             Canadian Standards

   serious electrical accidents result in injury                                                                          Association (CSA)

   —sometimes death—lost work time, medical

   costs and insurance claims, downtime, the

   list goes on.                                                                                                          TUV and VDE

      The cost to both the victim, the victim’s                                                                           (German standards

   family and the company involved, are                                                                                   organizations) are

   high. Yet many of these accidents can be                                                                               approval/listing

   prevented. The combination of training,                                                                                agencies

   good measurement technique, and the use

   of proper tools can significantly reduce the

   chance of an accident occurring.

   What are the Standards?                                                                                                United States

   To provide improved protection for users,                                                                              Department of

   industry standards organizations have                                                                                  Labor Mine Safety

   taken steps to clarify the hazards present           Go to www.fluke.com/safety to view The                            and Health

   in electrical supply environments. The               Fluke Electrical Measurement Safety Program                       Administration

                                                        and order your free copy of the Fluke Safety

   American National Standards Institute                video. This video makes the standards easy

   (ANSI), the Canadian Standards Association           to understand and can be used as part of

   (CSA), and the International Electro-                your own internal safety program.

   Technical Commission (IEC), have created                                                           That’s why independent testing is

   more stringent standards for voltage test                                                          so important. To be confident, check

   equipment used in environments of up to 1000 volts.                                                the product for the symbol and listing

      ANSI, CSA and IEC define four measurement categories of over-voltage transient                  number of Underwriters Laboratories

   impulses. The rule of thumb is that the closer the technician is working to the power              (UL), the Canadian Standards Associa-

   source, the greater the danger and the higher the measurement category number. Lower               tion (CSA), TÜV or another recognized

   category installations usually have greater impedance, which dampens transients and                testing organization. Those symbols can

   helps limit the fault current that can feed an arc.                                                only be used if the product successfully

   •  CAT (Category) IV is associated                                                                 completed testing to the agency’s

      with the origin of installation.                                                                standard, which is based on national/

      This refers to power lines at                                                                   international standards. That is the

      the utility connection, but also                                                                closest you can come to ensuring that

      includes any overhead and                                                                       the test tool you choose was actually

      underground outside cable runs,                                                                 tested for safety.

      since both may be affected by                                                                   What does the CE symbol indicate?

      lightning.                                                                                      A product is marked CE (Conformité

   •  CAT III covers distribution level                                                               Européenne) to show it conforms

      wiring. This includes 480-volt                                                                  to health, safety, environment and

      and 600-volt circuits such as                                                                   consumer protection requirements

      3-phase bus and feeder circuits,                                                                established by the European Commis-

      motor control centers, load                                                                     sion. Products from outside the Euro-

      centers and distribution panels.                                                                pean Union cannot be sold there unless

      Permanently installed loads are                                                                 they comply with applicable directives.

      also classed as CAT III. CAT III                                                                But manufacturers are permitted to

      includes large loads that can                                                                   self-certify that they have met the

      generate their own transients. At this level, the trend to using higher voltage levels in       standards, issue their own Declaration

      modern buildings has changed the picture and increased the potential hazards.                   of Conformity, and mark the product

   •  CAT II covers the receptacle circuit level and plug-in loads.                                   “CE.” The CE mark is not, therefore, a

   •  CAT I refers to protected electronic circuits.                                                  guarantee of independent testing.

   Some installed equipment may include multiple categories. A motor drive panel, for                 Why are Fluke products different?

   example, may be CAT III on the 480-volt power side, and CAT I on the control side.                 Don’t be confused by “Listed” vs.

                                                                                                      “Designed to” in your test tools.

   Independent testing labs help ensure safety compliance                                             IEC sets the standards but does not

   You want your tools and equipment to help you work safely. But how do you know that                test or inspect for compliance. So a

   a tool designed to meet a safety standard will actually deliver the performance you are            manufacturer can claim to “design

   paying for?                                                                                        to” a standard with no independent

      Unfortunately it’s not enough to just look on the box. The IEC (International                   verification. To be UL-Listed, CSA or

   Electrotechnical Commission) develops and proposes standards, but it is not responsible            TUV-Certified, a manufacturer must

   for enforcing the standards. Wording like “Designed to meet specification...” may not mean         employ the listing agency to TEST

   a test tool actually performs up to spec. Designer’s plans are never a substitute for an           the product’s compliance with the

   actual independent test.                                                                           standard. Look for the listing agency’s

                                                                                                      emblem on the meter.

   For more information, go to www.fluke.com/safety

  Safety
                              Service Information

                            Think of Fluke first for technical                                               Application note, literature code

                            service, repair and calibration                                                  2153519:

                                                                                                             Why calibrate test

Fluke customer support is ready to help                                                                      equipment?

                                                                                                             Why would

                                                                                                             a digital test

                                                                                                             tool need to be

                                                                                                             calibrated? It’s

                                                                                                             not as though

                                                                                                             any analog

                                                                                                             parts will go

                                                                                                             out of balance.

                                                                                                             Well, have any

                                                                                                             events occurred

                                                                                                             that would

                                                                                                             render your

                                                                                                             instruments

                                                                                                             less accurate or

                                                                                                             unsafe? Is accu-

                                                                                                             rate measurement essential to your

                                                                                                             operations? Are you trending data?

                                                                                                             Read this application note to find out

                                                                                                             what causes calibration problems

                                                                                                             and whether you should consider

                                                                                                             calibrating your test instruments.

                                                                                                             Visit www.fluke.com/why-calibrate

                                                                                                             Application note, literature code

                                                                                                             2138394:

Calibrating a thermometer.                                                                                   Shocking treatment

Technical service at your fingertips                                                                         Because of

We know Fluke tool users put their tools through the paces, so we’re ready to answer                         our commit-

your questions and help keep your tools in top shape. No matter what application, in                         ment to safety,

what industry. And we’ll do it through real technical service professionals in Everett,                      all Fluke

Washington.                                                                                                  equipment

                                                                                                             is designed

When you need questions answered, call Sales and Application Support at                                      to provide as

1-888-44-Fluke or email fluke-info@fluke.com                                                                 much protec-

The Fluke experts answering your call can help with just about any test tool question.                       tion as pos-

They specialize in:                                                                                          sible from

•  Advice on what to buy, from problem analysis to tool compatibility and configuration                      the inherent

   “If I’m working with three phase motors, what’s the best tool to use?”                                    dangers of

•  Help on how to use your tools in any application, from automotive to industrial                           working in the

   “How come I’m not getting a reading?”                                                                     unsettled sea

   “How do I transfer my test results?” “How do I measure harmonics?”                                        of electricity.

When your Fluke tools need repair or calibration, call Customer Support Services                             Fluke products are dropped, shocked,

at 1-888-99-Fluke or email service.status@fluke.com. Customers outside the U.S.                              short circuited, injected with thou-

email service.international@fluke.com or visit www.fluke.com/service to find your                            sands of volts of electricity and

nearest location.                                                                                            forced to endure extreme tempera-

If your tool isn’t working correctly, or if you dropped it, ran over it, or dunked it in the pool,           ture, just to get out the door.

call Fluke. If it’s not under warranty, we’ll give you a cost estimate over the phone. Once                  To learn more about our product tests,

you send it in, we’ll verify the problem, fix it, test it and put it back in the mail often in               visit www.fluke.com/shocking

less than five working days.

   Fluke recommends having your DMMs, Calibrators and ScopeMeter test tools calibrated

once a year—especially if you use them often or need accurate measurements to meet

regulations requirements. Calibration compares your tool’s measurements to the accuracy

standard—sort of like setting your watch to match an atomic clock. Some test tools live a

pretty rough life. If you calibrate them, you know they’re accurate—even after what you

put them through.

For more information on servicing your Fluke tools outside of the U.S., see page 2 for contact information.

                                                                                                                                 Service             
                                           Pick the right digital

                                                 multimeter for you

                               Digital Multimeter Selection Guide

                                                 Highest                            True-rms and      Designed          Designed          Waterproof

                                                 accuracy with     Industrial       built-in          for building      for HVAC/R        and chemical    Two powerful     4-20 mA loop

                                                 data logging      troubleshooting  thermometer       maintenance       technicians       resistant       tools in one     diagnostics

    Models                                            189          87V                   179               117               116          27              1587                  789

    Basic features                                                                                                           •

    True-rms readings                                 AC+DC        AC                    AC                AC                AC                           AC                    AC

    Basic dc accuracy                            0.025 %           0.05 %                0.09 %            0.5 %             0.5 %        0.1 %           0.09 %                0.1 %

    Wide bandwidth                               100 kHz           20 kHz                                                                 30 kHz

    Auto/manual ranging                               •            •                     •                 •                 •            •               •                     •

    Digits                                            4-1⁄2        4-1⁄2                 3-1⁄2             3-1⁄2             3-1⁄2        3-1⁄2                                 3-1⁄2

    Counts                                            50000        20000                 6000              6000              6000         3200            6000                  4000

    Measurements

    Voltage ac/dc                                     1000 V       1000 V                1000 V            600 V             600 V        1000 V          1000 V                1000 V

    Current ac/dc                                     10 A         10 A                  10 A              10 A              600 µA       10 A            400 mA                1A

    Resistance                                   500 MW            50 MW                 50 MW             40 MW             40 MW        32 MW           50 MW                 40 MW

    Frequency                                         1 MHz        200 kHz          100 kHz                50 kHz            50 kHz                       100 kHz               20 kHz

    Capacitance                                       50 mF        10 mF                 10 mF             10 mF             10 mF                        10 mF

    Temperature                                  +1350 °C          +1090 °C         +400 °C                             +400 °C                           +500 °C

    dB                                                60 dB

    Conductance                                       50 nS        50 nS                                                                  32 nS

    Duty cycle/pulse width                            •            •

    Motor drive measurements/low pass filter                       •                                                                                      •

    Continuity with beeper                            •            •                     •                 •                 •            •               •                     •

    Diode test                                        •            •                     •                 •                 •            •               •                     •

    Display

    Dual display                                      •                                                                                                                         •

    Analog bargraph                                   •            •                     •                 •                 •            •                                     •

    Backlight                                         •            •                     •                 •                 •                            •                     •

    Data storage and exchange

    Min/Max recording                                              •                     •                 •                 •            •               •                     •

    Min/Max recording/with time stamp                 •                                                                                                   •

    Fast Min/Max                                      250 µs       250  µs

    Display Hold/Auto (Touch) Hold                    •            •                     •                 •                 •            •                                     •

    Relative reference                                •            •                                                                      •                                     •

    PC interface                                      •                                                                                                                         •

    Data logging                                      •                                                                                                                    with     PC

    Readings memories                                 100

    Other features

    Automatic selection, LoZ                                                                               •

    Insulation test range                                                                                                                                 0.01 MW to 2 GW

    VoltAlert, non-contact ac voltage detector)                                                            •

    Real time clock                                   •

    Overmolded case, integrated holster               •                                  •                                                                                      •

    Removable holster                                              •                                       •                 •                            •

    ToolPak Magnetic Hangar compatibility             •            •                     •                 •                 •                                                  •

    Closed case calibration                           •            •                     •                 •                 •                            •                     •

    Separate battery door                             •            •                     •                 •                 •            •               •                     •

    Completely sealed/watertight                                                                                                          •

    Automatic power off                               •            •                     •                 •                 •                            •                     •

    Low battery indication                            •            •                     •                 •                 •            •               •                     •

    Operating temperature range                  –20  °C, +55  °C  –20 °C, +55 °C   –10  °C, +50  °C  –10  °C, +50  °C  –10  °C, +50  °C  –40 °C, +55 °C                   –20  °C, +55  °C

    4-20 mA                                                                                                                                                                     •

    24 V loop supply                                                                                                                                                            •

    Warranty and electrical safety

    Limited lifetime warranty                         •            •                     •                                                •

    Warranty (years)                                                                                       3                 3                            3                     3

    Input alert                                       •            •

    Dangerous voltage indication                      •            •                     •                 •                 •                            •                     •

    CAT III measurements                              1000 V       1000 V                1000 V            600 V             600 V        1000 V          1000 V                1000 V

    CAT IV measurements                               600 V        600 V                 600 V                                            600 V           600 V

    See page                                          12           14                    15                17                18           19              35                    43

                                                                                    More comprehensive              information       is  available       at www.fluke.com/dmm

10  Digital Multimeters
                                   Test faster and safer

                                                    with a new Fluke

                                  Move up to more measurement

                                                         performance and safety

Move up from your old 87 and benefit from more than a dozen improvements

Function                    Original 87             87V                           Benefit

Selectable filter for       No                      Yes                           Accurate voltage and frequency

motor drives                                                                      measurements on pulse width

                                                                                  modulated signals

Built-in thermometer        No                      Yes                           No separate thermometer required

Capacitance                 5 nf to 5 µF            5 nf to 10,000 µF             Measure more capacitors

V dc accuracy and           0.1 %, 10 µV            0.05 %, 10 µV                 Precise measurements in a

resolution                                                                        handheld tool

Display digits              13.5 mm x 7 mm          15.25 mm x 8.5 mm             30 % larger makes it easy to read

Backlight                   Green                   2-level, bright white         Easier to read in dark locations       87                          87V

Magnetic hanger             No                      Optional (included with kit)  Position meter for easy viewing

Peak capture                1 ms                    250 µS                        Record intermittent problems four      Get accurate voltage and frequency

                                                                                  times faster                           measurements on adjustable speed

CAT electrical safety       No                      Yes, 2nd edition ANSI and     Increased protection from 8 kV         motor drives with the 87V.

rating                                              IEC 61010                     spikes that can cause arc flash

Battery door                No                      Yes                           Change battery quickly without

                                                                                  breaking cal seal

Warranty                    Expired                 Limited lifetime              Lower cost of ownership

Move up from your old 8060 or 8062 and benefit from                             more than 20 improvements

Function                    8060                    189                           Benefit

Built-in recorder with      No                      Yes                           Record and view intermittent

time stamp                                                                        problems without a chart recorder

PC interface                No                      Yes, software optional        Transfer readings to a PC for

                                                                                  analysis and documentation

Built-in thermometer        No                      Yes, probe optional           No need to carry a separate

                                                                                  thermometer

Capacitance                 No                      5 nf to 50,000 µF             Measure capacitors with one tool

V dc and V ac               10 µV                   1 µV                          Precise measurements in a

resolution                                                                        handheld tool                          8060                        189

dBv and dBm                 Yes                     Yes                           Measure communication circuits

Duty cycle and pulse        No                      Yes                           Measure control circuits               Use the built-in data logging fea-

width                                                                                                                    ture of the 189 to record readings

In-line current             2A                      10 A, 1000 V fuse             Safely measure five times more         and the time they occurred to catch

                                                                                  current                                intermittent problems.

Relative offset             No                      Yes                           Remove test lead resistance

                                                                                  See small signal variations

Range selection             Manual,    8  switches  Auto/Manual range             Simpler to use, more durable

Peak capture,               No                      250 µS                        Record intermittent problems

MIN/MAX

Backlight                   No                      2-level, bright white         Easier to read in dark locations

Holster                     No                      Integrated overmold           Stands up to accidental drops

Magnetic hanger             No                      optional TPAK                 Position meter for easy viewing

CAT electrical              No                      Yes, 2nd edition              Increased protection from 8 kV

safety rating                                       ANSI and IEC                  spikes that can cause arc flash

Battery door                No                      Yes                           Change battery quickly without

                                                                                  breaking cal seal

Warranty                    Expired                 Limited lifetime              Lower cost of ownership

Move up from your old 70 or 20                      series and benefit from more than 15 improvements

Feature                            Original 77      179                Benefit

True-rms                           No               Yes                Accurate on non-linear signals

Accuracy, basic dc                 0.3 %            0.09 %             Three times more accurate

Temperature                        No               Yes                No need for a separate thermometer

Min/Max/Average                    No               Yes                Capture intermittent problems

Display size                       Small            20 % larger        Large, easy to read

Display backlight                  No               Yes                Easy to read in dark locations

Simple to use                      Yes              Yes                No retraining required

Probe holders                      Yes              Improved           One-hand operation                                77                          179

Latest electrical measure-         Not rated        1000 V CAT III,    Designed to withstand 8,000 volt peak transient

ment safety standards                               600 V CAT IV       impulses and protect against arc flash            The ultimate multi-purpose meter,

Optional magnetic hanger           No               Yes                Position meter in best location                   the 179 combines precision, safety

Warranty                           Expired          Limited lifetime   Lower cost of ownership                           and reliability to help you get any

Frequency                          No               Yes                Built in frequency counter                        job done.

Capacitance                        No               Yes                Measure motor capacitors and components

Max. ac voltage                    750              1000               Wider measurement range

Battery door                       No               Yes                Change battery quickly without breaking cal seal

                                                                                                                                    Digital Multimeters       11
                                               TFeluskteTo18o9ls LCoagtagliong

                                                                            M Voulultimmeet3e6r

                 Solve          complex problems for electronic                                                                     Log and document

                                                   and industrial appCliocnatteionnts

                                                The Fluke 189 is the most advanced meter with features,

                                                precision and accuracy to troubleshoot industrial and

                                                electronic equipment in the field or on the bench. The

                                                Fluke 189 has a built-in data logger to record measure-

                                                ments unattended. Recorded data can be viewed on

                                                the 189 or transferred to a PC with optional FlukeView®

                                                Forms software.

                                                •  Built in data logger (Fluke 189) records reading and

                                                   time to catch intermittent problems

                                                •  True-rms, 100 KHz bandwidth for precise

                                                   measurement of non linear signals

                                                •  0.025 % dc accuracy and 1 microvolt resolution for                               NEW! The 189/FVF2

                                                   bench meter performance in a handheld package                                    Data Logging Multimeter

                                                •  Measure 20 A for up to 30 seconds, 10 A continuous

                                                •  Temperature, capacitance, dB, frequency, pulse width                             and Software Combo Pack

                                                   and duty cycle to find more problems with one tool                               gives you a practical,

                                                •  Large bright white display with dual parameter                                   affordable approach to

                                                   readout to view multiple readings at once                                        predictive maintenance.

                                                •  Min/Max with timestamp to record signal fluctuations

                                                •  Peak capture to measure transients as short as 250 µS                            •  With built-in data logger, the

                                                •  Isolated IR communication port to send data to a PC                                 189 helps you track down

                                                   (with optional FVF pack)                                                            elusive, intermittent problems,

                                                •  Premium test leads and alligator clips (AC72) included                              monitoring equipment with

                                                •  New! Optional USB data cable with FlukeView Forms                                   any of its functions, while you

                                                •  New! Optional battery pack (BP189) extends battery                                  do other jobs

                                                   life to over 400 hours                                                           •  Overlay data from six meters

                                                                                                                                       or six time periods to find

                                                Electrical safety                                                                      cause and effect relationships

                                                All inputs are protected to measurement CAT III 1000 V                                 or for condition monitoring

                                                and CAT IV 600 V.                                                                      applications

                                                                                                                                    •  With break-through accuracy

                                                                                                                                       and precision, catch events as

                                                                                                                                       brief as 50 ms

                                                Available in non-logging version as Fluke 187                                       •  Designed for harsh environ-

                                                                                                                                       ments that would ruin most

                                                                                                                                       data loggers or multimeters

    Specifications – 189 and 187 DMMs                                                                                               •  Log up to 450 hours of data

                                                                                                                                       using the extended battery pack

                                                                                                                                    •  Turn data into meaningful

                                                                                                                               Best accuracy                graphs and tables using

    Function     Range and resolution                                                                     180 Series                   FlukeView Forms software

    V dc         50.000 mV, 500.00 mV, 3000.0 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0                 V  ± 0.025 %                 •  TPAK™ Magnetic Hanger

    V ac         50.000 mV, 500.00 mV, 3000.0 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0                 V  ± 0.4 %                      allows you to securely hang

    A dc         500.00 µA, 5,000 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A*                           ± 0.15 %                     your meter for monitoring or

    A ac         500.00 µA, 5,000 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A*                           ± 0.75 %                     hands-free use

    Resistance   500.00 W to 500.0 MW                                                                     ± 0.05 %                  •  Soft carrying case to protect

    Capacitance  1.000 nF to 50.00 mF                                                                     ± 1.00 %                     your investment

    Frequency    500.00 Hz, 5.0000 kHz, 50.000 kHz, 999.99 kHz                                            ± 0.005 %                 •  USB cable included with kit

    Temperature  -200 ºC to 1350 ºC (-328 ºF to 2462 ºF)                                                  ± 1 % of reading

    Duty cycle   10 % to 90 %, resolution 0.01 %                                                          —

    Pulse width  2 ranges, 499.99 ms and 999.9 ms, best resolution 0.01 ms                                3%

    dBm, dBv     -62 to +60, resolution 0.01dB                                                            0.1 dB

    *10 A continuous, 20 A for up to 30 seconds and not specified.                                                                  Included accessories

    Battery life: 72 hours typical (alkaline), 450 hours typical with Battery Extender (BP189)                                      Every 180 series meter comes pack-

    Size (LxWxD): 203 mm x 100 mm x 50 mm (8.00 in x 3.94 in x 1.97 in)                                                             aged with TL71 Silicone Test Leads,

    Weight: 0.545 kg (19.2 oz)                                                                                                      probe holders, two AC72 Alligator

                                                                                                                                    Clips, four AA batteries (installed),

    Recommended accessories – 189 and 187 DMMs                                                                                      CD-ROM (users manual and techni-

                                                                                                                                    cal notes) and operator’s guide.

                                                                                                                                    Ordering information

                                                                                                                                    Fluke-189/FVF2 Logging Multimeter

                                                                                                                                                       and Software

                                                                                                                                                       Combo Pack

          TL910                 TL81A                               C125                        BP189     FVF-SC2                   Fluke-189          Logging Multimeter

    Electronic Test Probes      Test Lead Kit             Meter Case      High Capacity Battery Pack      FlukeView Forms Software  Fluke-187          Digital Multimeter

    See page 63                 See page 63        See page 70              See page 65                   See page 65               FVF-SC2            FlukeView Forms

                                                                                                                                                       Software w/cable

    For more information and detailed           specifications, go        to www.fluke.com/dmm

12  Digital Multimeters
                                       FlukeView® Forms

                                                             Software

                                       Utilize this powerful tool to                                 Customize reports using your

                                analyze your measurements                                            specific data or company logo,

                                                                                                     spot trends and document

                                                                                                     interruptions or spikes.

                                            Harness the power of the data logging

                                            function on your Fluke Digital Multimeter.

                                            FlukeView Forms offers an easy-to-use,

                                            customizable solution to help you document

                                            logged data. Easy-to-use wizards allow you

                                            to download readings from your Fluke tool

                                            and display individual readings or a series of

                                            measurements.

                                            •  Graph data to help you detect trends,

                                               analyze, predict and prevent problems

                                            •  Print, save and share logged data

                                            •  Log live readings while connected to a PC,

                                               or leave your Fluke 189 in place to capture

                                               up to 1,000 readings for download to a PC

                                            •  Display readings from up to six different

                                               meters on the same graph to show links                A single graph overlaying two time

                                               between multiple processes, events and                periods makes analysis easier.

                                               locations

                                            •  Record and display any function the

                                               meter measures: volts, ohms, frequency,

                                               capacitance, temperature, diode testing

                                               and more

                                            •  Free demo-reader download allows

                                               co-workers or clients to open your report

                                               and interact with captured data

                                            •  Export data into Microsoft® Excel

To take a test drive of the power

of FlukeView Forms, download

demonstration software for free at

www.fluke.com/flukeviewforms

                                                                                                     Use the FlukeView designer to turn

                                                                                                     simple time and event data into

                                                                                                     fully customized reports.

                                            You can share reports and add notes to draw

                                            attention to and explain anomalies.

Fluke 189,                   189/FVF2       Kit and 187 capabilities

                             189/FVF2  189     187  Benefit

Fluke 180 Series Multimeter  •         •       •    Fluke’s top-of-the-line multimeter with maximum

and premium test leads                              feature set to troubleshoot any situation.

PC connectable               •         •       •    Use to download and document test results.

Logging capabilities         •         •            Reduce man-hours by using logging to find

                                                    problems and intermittent glitches.

FlukeView Forms software     •                      Document and print measurement data in a clear   Compatible with

                                                    and organized format.

Overlay and graph data from  •         •            Find elusive cause/effective relationships.      FVF-SC2  Fluke 187 and 189

up to six meters                                                                                              Digital Multimeters,

Compatible with FlukeView    •         •       •    Allow data to be distributed and shared with              Fluke 1550B

Forms Demo Reader                                   individuals throughout a company for free.                MegOhmMeter,

                                                                                                              Fluke 789

                                                                                                              ProcessMeter™

                                                                                                     FVF-SC1  Fluke 53-II and 54-II

                                                                                                              Thermometers

                                                                                                     FVF-SC3  Fluke 45 Bench Meter

For more information and detailed specifications, go to www.fluke.com/flukeviewforms

                                                                                                              Digital Multimeters        13
                                                                                        Fluke 87V

                                    Industrial Multimeter

                                                          Diagnostic functions for                                             Application note, literature code

                                    maximum industrial productivity                                                            2155830:

                                                                                                                               Multimeter measurements

                                                       The Fluke 87V has measurement functions, trouble-                       on adjustable speed drives

                                                       shooting features, resolution and accuracy to solve more                utilizing the Fluke 87V DMM

                                                       problems on motor drives, in-plant automation, power                    How do I

                                                       distribution and electro-mechanical equipment.                          troubleshoot

                                                       New features for maximum productivity                                   an adjustable

                                                       •                                                                       speed drive

                                                          Unique function for accurate voltage and frequency                   with a digital

                                                          measurements on adjustable speed motor drives and                    multimeter?

                                                          electrically noisy equipment (87V and 87V Ex)                        Read this and

                                                       •  Large digit display with bright two level backlight                  other applica-

                                                          makes the 87V significantly easier to read                           tion notes at

                                                       •  Measure 20 A for up to 30 sec, 10 A continuously                     www.fluke.

                                                       •  Optional magnetic hanger for easy setup and viewing                  com/library

                                                          while freeing your hands for other tasks (TPak)

                                                       •  Expanded capacitance range to 10,000 µF

                                                       •  Built-in thermometer (87V)

                                                       Electrical safety

                                                       All inputs are protected to CAT III 1000 V and CAT IV

                                                       600 V. They can withstand impulses in excess of 8,000 V

                                                       to help protect you from arc blast resulting from surges

                                                       and spikes.

                                                       Available in intrinsically safe version as the

                                                       Fluke 87V Ex.

                                                       Also available as 83V average responding

                                                       multimeter, see below for specifications

    Features – 87V and 83V DMMs                                                                                             Fluke 87V/E2 Industrial

                                                                                                                            Electrician’s Combo Kit

    Feature                                                                                87V Ex  87V             83V      Make industrial troubleshooting even

    ATEX II 2G EEx ia IICT4 safety rating for use in Zone 1 and Zone 2                     •                               more productive with accessories.

    True-rms ac voltage and current for accurate measurements on non linear signals        •            •                  •  87V Industrial Multimeter

    Selectable filter for accurate voltage and frequency measurements on motor drives      •            •                  •  New! C35 lightweight soft case

    0.05 % dc accuracy                                                                     •            •                     to provide optimal protection

    4-1/2 digit mode for precise measurements                                              •            •                      and storage

    Built-in thermometer lets you carry one less tool                                      •            •                   •  TL224 1.5 m silicone leads

    Large display digits and two level bright white backlight for increased visibility     •            •          •           resist heat

    10,000 µF capacitance range for components and motor caps                              •            •          •        •  TP238 removable probes with

    Peak capture to record transients as fast as 250 µs                                    •            •                      4 mm of exposed metal for use

    Measure up to 1000 V ac and dc                                                         •            •          •           on industrial circuits

    Measure up to 10 A, 20 A for up to 30 seconds                                          •            •          •        •  AC220 retractable long reach

    Auto and manual ranging for maximum flexibility                                        •            •          •           alligator clips

    Analog bargraph                                                                        •            •          •        •  ToolPak™ meter hanging accessory

    Frequency to 200 kHz and % duty cycle                                                  •            •          •           to hold meter to steel surfaces

    Min/Max and average recording to capture variations automatically                      •            •          •        •  80BK K-type temperature probe

    Relative mode to remove test lead resistance from low ohms measurements                •            •          •

    Access door for fast battery changes without breaking the calibration seal             •            •          •

                                                                                                                               Included accessories

    Specifications – 87V and 83V DMMs                                                                                          Every Fluke 83V and 87V meter

                                                                                                                               comes packaged with TL75 Test

                                                                                                                               Leads, AC72 Alligator Clips,

                                                                                                   Basic accuracy              holster, 9 V battery (installed),

    Function                   Range and resolution                                                87V             83V         80BK Temperature Probe (87V only)

    DC volts                   600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V                         0.05 %         0.1 %        CD-ROM (users manual and techni-

    AC volts                   600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V                    0.7 % (true-rms)    0.5 %        cal notes) and operator’s guide.

    DC current                 600.0 µA, 6000 µA, 60.00 µA, 600.O mA, 6.000 A, 10.00 A             0.2 %          0.4 %

    AC current                 600.0 µA, 6000 µA, 60.00 µA, 600.O mA, 6.000 A, 10.00 A        1.0 % (true-rms)    1.2 %        Ordering information

    Temperature (excl. probe)  -200 °C to 1090 °C (-328 °F to 1994 °F)                             1.0 %           —           Fluke-87-5       Industrial True-rms

    80BK Temperature Probe     -40 °C to 260 °C (-40 °F to 500 °F)                                 2.2 °C or 2 %   —                            Multimeter with

    Resistance                 600.0 W, 6.000 kW, 60.00 kW, 600.0 kW, 6.000 MW, 50.00 MW           0.2 %          0.4 %                         Temperature

    Capacitance                10.00 nF, 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 9,999 µF          1.0 %          1.0 %        Fluke-87-5/E2 Industrial

    Frequency                  199.99 Hz, 1.9999 kHz, 19.999 kHz, 199.99 kHz                       0.005 %        0.005 %                       Electrician’s

    Battery life: 400 hours typical with backlight off. Size (LxWxD): 201 mm x 98 mm x 52     mm (7.9 in x 3.8 in x 2 in).                      Combo Kit

    Weight: 355 g (22 oz)                                                                                                      Fluke-83-5       Industrial Multimeter

    For more information and detailed specifications, go to www.fluke.com/dmm

14  Digital Multimeters
                                                      Fluke 179 Digital

                                                                                     Multimeter

                              Versatile meters for maintenance

                                                                                     and field service

                                                   The 179 true-rms Multimeter has the features needed

                                                   to find most electrical and HVAC problems. Simple

                                                   to use with significant improvements over the original

                                                   Fluke 70 Series like true-rms, the 179 has more

                                                   measurement functions, conformance to the latest

                                                   safety standards and a much larger display that’s

                                                   easier to view.

                                                   Features include:                                                                                 179/EDA2 Electronics
                                                   •
                                                      Wide 1000 V measurement range                                                                  Multimeter and Deluxe

                                                   •  True-rms for precise measurement of non                                                        Accessory Combo Kit

                                                      linear signals                                                                                 •  179 True-rms Digital Multimeter

                                                   •  Capacitance, resistance, continuity and frequency                                              •  New! C35 lightweight soft case

                                                   •  Built-in thermometer (Fluke 179 only)                                                             to provide optimal protection

                                                   •  Large, easy-to-read display                                                                       and storage

                                                   •  Backlight for work in dimly lit areas                                                          •  TL910 Electronic Test Probes

                                                      (Fluke 177 and179 only)                                                                        •  TL224 SureGrip™ Silicone Test

                                                   •  Min/Max/Avg to record signal fluctuations                                                         Leads resist heat

                                                   •  Free your hands with the optional TPAK magnetic                                                •  AC280 SureGrip™ Heavy Duty

                                                      hanger (Fluke TPAK)                                                                               Hook Clips

                                                   Electrical safety                                                                                 •  80BK Type-K temperature probe

                                                   All inputs are protected to measurement CAT III 1000 V                                            •  ToolPak™ meter hanging accessory

                                                   and CAT IV 600 V. This meter can withstand transient                                                 to hold meter to steel surfaces

                                                   impulses in excess of 8000 V to help protect you from

                                                   arc blasts resulting from surges and spikes.

Features – 175,                                    177  and              179              DMMs

Feature                                                                                   179                    177               175

Max voltage                                                                               1000                   1000              1000

True-rms                                                                                     •                        •              •           179/1AC-II Electrician’s

Temperature                                                                                    •                                                 Multimeter and Voltage

Basic dc accuracy                                                                         0.09 %           0.09 %         0.15 %

Backlight                                                                                      •                   •                             Tester Combo Kit

Min/Max/Avg                                                                                    •                   •                   •        •  179 True-rms Digital Multimeter

ToolPak meter hanging    kit  with  magnet                                                Opt                    Opt               Opt            •  1AC-II VoltAlert™ Non-Contact

                                                                                                                                                     Voltage Detector

                                                                                                                                                  •  New! C35 lightweight soft case to

Specifications – 179, 177 and 175                                                                          DMMs                                      provide optimal protection and storage

                                                                                                                                                  •  AC220 retractable long reach

Function                                           Range and resolution                                             Best accuracy                    alligator clips

DC voltage                          600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V                         ±  0.09 % (Models 177 and           179)  •  TP220 sharp 12 mm stainless steel

                                                                                                           ± 0.15 % (Model 175)                      tip provides reliable contact

AC voltage1                         600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V                            ± 1.0 % of reading                     •  TL224 1.5 m silicone leads resist heat

DC current                                  60.00 mA, 400.0 mA, 6.000 A, 10.00 A2                          ± 1.0 % of reading                     •  ToolPak™ meter hanging accessory

AC current2                                 60.00 mA, 400.0 mA, 6.000 A, 10.00 A2                          ± 1.5 % of reading                        to hold meter to steel surfaces

Resistance                    600.0 W, 6.000 kW, 60.00 kW, 600.0 kW, 6.000 MW, 50.00 MW                    ± 0.9 % of reading                     •  80BK K-type temperature probe

Capacitance                                   1000 nF, 10.00 µF, 100.0 µF, 9999 µF                         ± 1.2 % of reading

Frequency3                                  99.99 Hz, 999.9 Hz, 9.999 Hz, 99.99 kHz                        ± 0.1 % of reading

Temperature (Model 179)                       -40 ºC to +400 ºC (-40 ºF to +752 ºF)                              1.0 % of reading                    Included accessories

1All ac voltage and ac current ranges are specified from 5 % of range to 100 % of range.
210 A continuous, 20 A for up to 30 seconds.
3Voltage frequency is specified from 2 Hz to 100 kHz. Current Frequency is specified from 2 Hz to 30                                                 Every Fluke 170 Series meter
                                                                                                           kHz.
                                                                                                                                                     comes packaged with TL75 test
Battery life: 200 hours typical for alkaline. Size (HxWxL): 4.3 cm x 9.0 cm x 18.5 cm (1.7 in x 3.5 in     x 7.3 in)
                                                                                                                                                     leads, 9 V battery (installed) and

Recommended accessories – 179, 177 and 175 DMMs                                                                                                      manual. The Fluke 179 comes with

                                                                                                                                                     an 80BK Temperature Probe.

                                                                                                                                                     Ordering information

                                                                                                                                                     Fluke-179         Digital Multimeter

                                                                                                                                                     Fluke-179/1AC-II Electricians

                                                                                                                                                                       Combo Kit

         L210                       TL220               C510                              PV350                           i400s                      Fluke-179/EDA2    Electronics

     Probe Extender           SureGrip Industrial       Carrying Case                Pressure-Vacuum                      AC Current Clamp                             Combo Kit

     with light               Test Lead Set             See page 70                       Module                          See page 66

     See page 64              See page 61                                                               See page 65                                                                     Fluke-175         Digital Multimeter

For  more information and detailed specifications, go to                 www.fluke.com/dmm                                                           Fluke-177         Digital Multimeter

                                                                                                                                                                Digital Multimeters          15
                       Fluke Family of True-rms

                                                 Digital Multimeters

                                                 Engineered by Fluke for

                                                     working professionals

    Commercial                         electricians                            HVAC/R technicians

                                                 Fluke 117                                              Fluke 116

                                                 • VoltAlert™ non-contact                               • Temperature to 400 °C
                                                     voltage detection                                  • Resistance, continuity,

                                                 • LoZ low impedance                                    frequency and

                                                     input for safer                                    capacitance

                                                     troubleshooting                                    • LoZ low impedance

                                                 • Resistance, continuity,                              input for safer

                                                     frequency and                                      troubleshooting

                                                     capacitance                                        • AC/DC voltage to 600 V,

                                                 • AC/DC voltage to 600 V,                              ac/dc current to 600 μA

                                                     ac/dc current to 10 A

            Fluke 112                                                          Fluke 12, 16

    Field           service            technicians                             Basic electrical

                                                 Fluke 115                                              Fluke 114

                                                 • Resistance, continuity,                              • LoZ low impedance
                                                     frequency and                                      input for safer

                                                     capacitance                                        troubleshooting

                                                 • AC/DC voltage to 600 V                               • Resistance and
                                                 • AC/DC current to 10 A                                continuity

                                                                                                        • AC/DC voltage to 600 V

    Fluke 110, 111                                                             Fluke  7-600

    Basic features                                                             114              115     116                  117

    True-rms readings                                                          ac               ac      ac                   ac

    Basic dc accuracy                                                          0.5 %            0.5 %   0.5 %                0.5 %

    Digits                                                                     3-1⁄2            3-1⁄2   3-1⁄2                3-1⁄2

    Counts                                                                     6000             6000    6000                 6000

    Measurements

    Voltage ac/dc                                                              600 V           600 V   600 V               600 V

    Current ac/dc                                                              —                10 A    600 µA               10 A

    Resistance                                                                 40 MW            40 MW   40 MW                40 MW

    Frequency                                                                  —                50 kHz  50 kHz               50 kHz

    Capacitance                                                                —                10 mF   10 mF                10 mF

    Temperature                                                                —                —       +400 °C              —

    Display

    Analog bargraph                                                            •                •       •                    •

    Large backlit display                                                      •                •       •                    •

    Data storage and exchange

    Min/Max recording                                                          •                •       •                    •

    Display hold/auto touch hold                                               •                •       •                    •

    Other features

    Automatic selection, LoZ                                                   •                        •                    •

    VoltAlert, non-contact ac voltage  detector                                                                              •

    For more information and detailed specifications, go to www.fluke.com/dmm

16  Digital Multimeters
       Fluke 117 and 115 True-rms

                                           Digital Multimeters

               Designed for commercial electricians                                                                Application note, literature code

                                        and field service technicians                                              1260729:

                                                                                                                   Why true-rms?

                                           Fluke 117                                                               If you’re

                                                                                                                   measuring

                                           The Fluke 117 is the ideal meter for demanding settings                 non-linear             Why true-rms?

                                           like commercial buildings, hospitals and schools. The 117               loads like             Non-linear loads need a true-rms

                                                                                                                                    current clamp for accurate readings                                                                    Application Note

                                           includes integrated non-contact voltage detection to help               variable                                                                                                                can usually be separated into

                                                                                                                                                                                                                                           one of three categories:

                                                                                                                                                                                                                                           1. Too much current.

                                           get the job done faster.                                                                                                                                                                        2. Too much heat in the

                                                                                                                   frequency                                                                                                               electrical enclosure.

                                                                                                                                                                                                                                           3. Faulty circuit breaker

                                                                                                                                                                                                                                           (or fuse).

                                                                                                                                                                                                                                           Your first instinct will probably

                                                                                                                                                                                                                                           be to measure the current with

                                                                                                                   drives, solid                                                                                                           a current clamp while the load

                                                                                                                                                                                                                                           is on. If the current is within

                                           The 117 features include:                                                                                                                                                                       the circuit rating, you may be

                                                                                                                                                                                                                                           tempted to replace the circuit

                                                                                                                                                                                                                                           breaker.

                                           •        VoltAlert™ Technology for integrated non-contact               state heater

                                                    voltage detection                                              drives, or                  Figure 1.  One current—two readings. Which do you trust? The branch circuit above feeds a

                                                                                                                                               non-linear load with distorted current. The true-rms clamp reads correctly but the average

                                                                                                                                               responding clamp reads low by 32 percent.

                                                                                                                   electronics,                                                                                                            Figure 2.  A computer load.

                                           •        AutoVolt feature for automatic ac/dc voltage selection                                     Introduction                                                                                Non-linear loads that cause

                                                                                                                                                                                                                                           measurement errors.

                                                                                                                                               Troubleshooting the electrical             lower cost. They give correct

                                                                                                                                               service feeding adjustable                 readings for linear loads such

                                                                                                                   you need a                  speed motor loads can be diffi-            as standard induction motors,

                                           •                                                                                                   cult if you don’t have the right           resistance heaters, and incan-

                                                    LoZ: low input impedance prevents false readings due                                       tools. New solid state motor               descent lights. But when loads

                                                                                                                                               drives and heating controls                are non-linear, containing

                                                                                                                                               often conduct non-sinusoidal               semiconductors, the average

                                                                                                                                               (distorted) current. In other              responding meters typically

                                                                                                                   true-rms tool               words, the current occurs in               read low. Worst case non-

                                                                                                                                               short pulses rather than the               linear loads include small

                                                    to “ghost voltage”                                                                         smooth sine wave drawn                     adjustable speed drives (5 hp

                                                                                                                                               by a standard induction motor.             or less) connected line to line

                                                                                                                                               The current wave shape can                 across two phases of a 480 V,

                                                                                                                                               have a drastic effect on a                 three-phase system, solid state

                                                                                                                   to get accurate             current clamp reading.                     heater controls connected

                                           •                                                                                                   Basically, there are two                   single phase to 240 V, or

                                                    Large display and white LED backlight to work in                                           types of current clamps                    computers connected to 120 V.

                                                                                                                                               commonly available: “average               When troubleshooting a branch

                                                                                                                                               responding” and “true-rms.”                circuit that suffers from circuit

                                                                                                                                               The average responding units               breaker tripping (or fuse blow-

                                                                                                                   readings.                   are widely used and are usually            ing), the cause of the trouble

                                                                                                                                                                                                                                           Figure 3.  An adjustable speed  motor  load.

                                                    poorly lit areas more effectively                                               From  the  Fluke      Digital          Library        @  www.fluke.co                                  m/library

                                           •        Compact design for one-handed operation                        Average

                                           •        Min/Max/Average to record signal fluctuations                  responding meters will read low,

                                           •        Compatible with optional magnetic hanger (ToolPak™)            up to 30 or 40 percent low in some

                                                    for hands free operation                                       cases. This application note explains

                                           •        Current measurement 20 A (30 seconds momentary;                what true-rms is and when you need

                                                    10 A continuous)                                               it in your test tool.

                                           •        Resistance, continuity, frequency and capacitance              Want to read more? Download this

                                           Fluke 115                                                               and other application notes at

                                                                                                                   www.fluke.com/library

                                           The new Fluke 115 is the solution for a wide variety of

                                           electrical and electronic testing applications.

                                           The 115 features include:

                                           •        Large display and white LED backlight to work in poor-

                                                    ly lit areas more effectively

                                           •        Compact ergonomic design for

                                                    one-handed operation

                                           •        Min/Max/Average to record signal

                                                    fluctuations

                                           •        Resistance, continuity, frequency and capacitance

Features – 117 and 115                                            DMMs

Feature                                                                                117                 115

VoltAlert™                                                                             •

AutoVolt/LoZ                                                                           •

Analog bargraph                                                                        •                   •

Large backlit digital display                                                          •                   •    117/322 Electrician’s

True-rms for accurate measurements  on  non-linear  loads                              •                   •    Combo Kit

Min/Max recording                                                                      •                   •    •

Display hold                                                                           •                   •       117 True-rms digital multimeter

3-1⁄2 digits                                                                           •                   •       with non-contact voltage detection

6000 counts                                                                            •                   •    •  New! C115 Deluxe carrying case

CAT III 600 V safety rated                                                             •                   •       with shoulder strap

                                                                                                                •  322 Compact clamp meter

Specifications – 117 and 115 DMMs                                                                               •  TL75 Hard Point Test Lead Set

                                                                                                                •  ToolPak Magnetic Meter Hanging

                                                                                                                   Strap

Function                                            Range and resolution                    Best accuracy

Volts ac/dc                                                600 V                            0.5 % + 2

Current ac/dc                                              10 A                             1.0 % + 3              Included accessories

Resistance                                                 40 MW                            0.9 % + 2

Capacitance                                         1 nF to 9,999 µF                        1.9 % + 2              TL75 Test leads, holster, users

Frequency                                                  5 Hz to 50 kHz                   0.1 % + 2              manual and 9 V battery (installed).

Diode                                                      2V                               0.9 % + 2              Ordering information

Recommended accessories – 117 and 115 DMMs                                                                         Fluke-117        Multimeter with

                                                                                                                                    Non-Contact Voltage

                                                                                                                   Fluke-117/322    Electrician’s

                                                                                                                                    Combo Kit

                                                                                                                   Fluke-115        Multimeter

       ToolPak™                     TL220                                  C50

Meter Hanger                   SureGrip Industrial                Carrying Case

       See page 71             Test Lead Set                      See page 70

                                             See page 61

For more information and detailed specifications, go to www.fluke.com/dmm

                                                                                                                                  Digital Multimeters                                                                                                                                    17
                                                Fluke 116 and 114

                                            Digital Multimeters

                                   Designed for HVAC/R technicians                                                                 Application note, literature code

                                        and electrical troubleshooting                                                             2434064:

                                                                                                                                   Fossil fuel heating

                                            Fluke 116                                                                              equipment

                                            The Fluke 116 was specifically designed for the HVAC                                   This            Fossil fuel heating

                                                                                                                                   application     equipment

                                            professional. It has everything needed in an HVAC meter                                                principles and troubleshooting

                                                                                                                                   note explains   techniques                                                                              Application                     Note

                                            including temperature and microamp measurements to                                                     This application note was written

                                                                                                                                   the basic       to provide you with an understand-

                                                                                                                                                   ing of the basic principles of fossil

                                                                                                                                                   fuel heating systems and how to

                                            quickly troubleshoot problems with HVAC equipment and                                                  troubleshoot these systems using

                                                                                                                                                   thermometers, digital multimeters

                                                                                                                                   principles      (DMMs), clamp meters, pressure/

                                                                                                                                                   vacuum modules and other acces-

                                                                                                                                                   sories. Heat pumps and forced air

                                            flame sensors.                                                                                         electric heat furnaces are discussed

                                                                                                                                   of fossil fuel  in other application notes available

                                                                                                                                                   from Fluke.

                                                                                                                                   heating         Heating systems

                                            The 116 features include:                                                                              principles

                                                                                                                                                   Forced-air heat is generated at

                                                                                                                                                   a central furnace and is then

                                                                                                                                                   distributed and delivered to the

                                            •                                                                                      systems         conditioned space via a duct                    DMM with microamps capability testing the flame rectification circuit.

                                                Built in thermometer for HVAC applications                                                         system. A properly designed

                                                                                                                                                   heating system will generate

                                                                                                                                                   quiet, filtered, and comfortable       •  A heat exchanger                while newer high efficiency

                                                                                                                                                   air into the conditioned zone.         •  A flue gas exhaust chamber      furnaces are 78 % to 85 %

                                                                                                                                                   Modern systems have been               •  A forced air circulating fan    efficient when used with induced

                                            •   Microamps to test flame sensors                                                    (gas and oil)   recently designed that will also          and,                            draft fans. Modern condensing

                                                                                                                                                   filter the air electronically, modu-   •  A controller section.           furnaces, however, are 90-95 %

                                                                                                                                                   late airflow as zone temperatures      Newer units often include a        efficient.

                                                                                                                                                   change, and bring in fresh outside     secondary heat exchanger to        Modern fossil fuel furnaces also

                                                                                                                                                   air based on occupied time.            increase efficiency and an auxil-  come equipped with electronic

                                            •                                                                                                            There are three types of fossil  iary fan for combustion gases.     controls for ignition, fan speed

                                                Min/Max/Average to record signal fluctuations                                      and how to      fuel heating systems predomi-          Since the newer units substan-     control, electronic thermostats,

                                                                                                                                                   nantly available on the market         tially cool the combustion gases,  and safety controls. The typical

                                                                                                                                                   today. These include natural gas,      removing water vapor from the      operating pressure of the natural

                                                                                                                                                   liquefied petroleum (LP) and fuel      combustion gases, they often are   gas furnaces at the burner is

                                                                                                                                                   oil forced-air furnaces.               called condensing high-efficiency  3.5 inches of water column.

                                            •                                                                                      troubleshoot                                           furnaces. Additionally, they       Natural gas is predominantly

                                                Large white LED backlight to work in poorly lit areas                                              Fossil fuel forced-air                 will have plastic flue gas piping  used as the preferred fuel in

                                                                                                                                                   heating                                instead of older more traditional  larger cities and communities

                                                                                                                                                   Forced-air fossil fuel furnaces are    metal flue pipe since the gas      where main gas lines are

                                                                                                                                                   factory manufactured, packaged         temperatures are much lower        available. Fuel oil and Liquid

                                                                                                                                                   heating units that include:            than less efficient older units.   Petroleum (LP) heating furnaces

                                            •   Compact ergonomic design for one-handed operation                                  them using      •     A combustion chamber                Older standard gas furnaces     are more popular in rural

                                                                                                                                                         designed for gas or oil          were 65 % to 78 % efficient,       communities.

                                            •   Min/Max/Average to record signal fluctuations                                      thermometers,            From  the             Fluke   Digital  Library               @   www.fluke.com/library

                                            •   Compatible with optional magnetic hanger (ToolPak™)                                DMMs,

                                            •   Resistance, continuity, frequency and capacitance                                  clamp meters, pressure/vacuum

                                                                                                                                   modules, and other accessories. The

                                            Fluke 114                                                                              instructions cover the thermostat

                                            The new Fluke 114 is the troubleshooting tool for “go/                                 controls, fan controls, flame

                                            no-go” testing. It includes a feature to prevent false                                 verification controls, and cad cell

                                            readings caused by ghost voltage.                                                      testing.

                                            The 114 features include:                                                              Want to read more? Download this

                                            •   AutoVolt: Automatic ac/dc voltage                                                  and other application notes at

                                                selection                                                                          www.fluke.com/library

                                            •   LoZ: Helps prevent false readings due to ghost voltage

                                            •   Large white LED backlight to work in poorly lit areas

                                            •   Compact ergonomic design for

                                                one-handed operation

                                            •   Resistance, continuity, frequency and capacitance

    Features – 116 and 114                                             DMMs

    Feature                                                                                  116                 114

    Temperature measurements                                                                 •

    AutoVolt/LoZ                                                                             •                    •

    Analog bargraph                                                                          •                    •             116/62 HVAC Combo Kit

    Large backlit digital display                                                            •                    •             •  Fluke 116 HVAC Multimeter with

    True-rms for accurate measurements  on  non-linear  loads                                •                    •                Temperature and Microamps

    Min/Max recording                                                                        •                    •             •  Fluke 62 Infrared Thermometer

    Display hold                                                                             •                    •             •  TL75 Hard Point Test Lead Set

    3-1⁄2 digits                                                                             •                    •             •  ToolPak™ Magnetic Meter

    6000 counts                                                                              •                    •                Hanging Strap

    CAT III 600 V safety rated                                                               •                    •             •  New! C115 Deluxe carrying case

                                                                                                                                   with shoulder strap

    Specifications – 116 and 114 DMMs                                                                                           •  New! 80PK-11 Pipe Wrap

                                                                                                                                   Thermocouple

                                                                                                                                •  Fluke 80AK Thermocouple Adapter

    Function                                            Range and resolution                      Best accuracy                 •  Fluke 80BK B-Type Integrated

    Volts ac/dc                                                600 V                              0.5 % + 2                        Temperature Probe

    Current ac/dc                                              10 A                               1.0 % + 3

    Temperature (116 only)                                     +400 °C                            1.0 % + 18

    Resistance                                                 50 kHz                             0.9 % + 2                        Included accessories

    Capacitance (116 only)                                  1 nF to 9,999 µF                      1.9 % + 2                        TL75 Test Leads, 80BK Integrated

    Frequency (116 only)                                       5 Hz to 50 kHz                     0.1 % + 2                        Temperature Probe (116 only),

    Diode (116 only)                                           2V                                 0.9 % + 2                        holster, users manual and 9 V

                                                                                                                                   battery (installed).

    Recommended accessories – 116 Digital Multimeter                                                                               Ordering        information

                                                                                                                                   Fluke-116       HVAC Multimeter

                                                                                                                                                   with Temperature

                                                                                                                                                   and Microamps

                                                                                                                                   Fluke-116/62    HVAC Combo Kit

             80AK                  80PK-24                                     80PK-8                    80BK                             Fluke-114       Electrical Multimeter

    DMM Adapter             SureGrip Air Temperature Probe     Pipe Clamp Temperature Probe  Integrated DMM Temperature  Probe

    See page 69                    See page 68                       See page 68                  ships with 116

                                                                                                                              See page 68

    For more information and detailed specifications, go to www.fluke.com/dmm

18  Digital Multimeters
                                                                           Fluke 77-IV

                                            Digital Multimeter

                             Versatile meters for field service                                                                Fluke 27 waterproof

                                                                                or bench repair                                multimeter

                                                                                                                               Completely

                                         The new 77-4 digital multimeter has the features needed                               sealed for extreme

                                         to repair most electrical and electronic problems.                           This     conditions

                                         meter is simple to use and has significant improvements                               Designed for U.S.

                                         over Fluke’s original 70 Series with more measurement                                 military, mining and

                                         functions, conformance to the latest safety standards, and                            other extreme appli-

                                         a much larger display that’s easier to view.                                          cations. A special

                                                                                                                               case with o-rings

                                         Measures                                                                              prevents water from

                                         •  Wide 1000 V measurement range                                                      entering the input

                                         •  Average responding ac measurements                                                 jacks, switches and

                                         •  0.3 % accuracy                                                                     fuse door. Meets

                                         •  10 Amps continuous                                                                 military specifica-

                                         •  Frequency and capacitance                                                          tions for vibration,

                                         •  Resistance and continuity                                                          shock and water

                                         Features                                                                              resistance.

                                         •  Large display                                                                      •  Waterproof design

                                         •  Backlight for work in dim areas                                                       with rugged, o-ring

                                         •  Min / Max to record signal fluctuations                                               sealer case protects

                                         •  Integral holster with probe holders                                                   rotary switch, input

                                         •  Free your hands with the optional TPAK                       magnetic                 jacks, battery and

                                            hanger                                                                                fuse door

                                         •  Auto and Manual ranging                                                            •  Operates from -15 °C

                                                                                                                                  to +55 °C (5 °F to

                                                                                                               Made               131 °F) and 95 %

                                                                                                               in the             relative humidity

                                                                                                               U.S.A.

                                                                                                                            Fluke 73-III

                                                                                                                            The Fluke 73-III product

Features – 77-IV                            Digital Multimeter                                                              represents one of the best

                                                                                                                            selling multimeter designs

                                                                                                                            of all time. It’s classic

Feature                                     Old 77                   New 77-IV     Benefit                                  simplicity combined with

Accuracy                                        0.3 %                0.3 %         Same great accuracy                      attractive feature set make

True-rms                                        No                   No            Same familiar readings                   this meter the perfect

Frequency                                       No                   Yes           Built in frequency counter               choice for electronic and

Capacitance                                     No                   Yes           Test components                          automotive applications.

Maximum ac voltage                              750                  1000          Wider measurement range

Min/Max/Average                                 No                   Yes           Capture transients automatically         The 73-III features

Display backlight                               No                   Yes           Usable in dim areas                      include:

Battery door                                    No                   Yes           Fast battery changes                     •  Average responding

Probe holders                                   No                   Yes           One-hand operation                       •  Measures both amps and milliamps

Overvoltage category safety  rating         Not rated                600 V CAT IV  Higher level of protection               •  Removable high impact holster

Optional magnet hanger                          No                   Yes           Position meter in best location          •  Manual or autoranging

Specifications – 77-IV                                      Digital Multimeter

Function                                 Range                       Best accuracy                      Best resolution

V dc                                 600.0 mV to 1000 V              ± (0.3 % + 1)                         0.1 mV

V ac                                     6.000 V to 1000 V           ± (2.0 % + 2)                         1.0 mV              Fluke 77-IV

A dc                                     60.00 mA to 10 A            ± (1.5 % + 2)                         0.01mA              included accessories

A ac                                     60.00 mA to 10 A            ± (2.5 % + 2)                         0.01 mA             TL75 test leads, 9 V battery

Resistance                               600.0 Ω to 50 MΩ            ± (0.5 % + 1)                             0.1 Ω           (installed) and manual.

Capacitance                              1 nF to 9,999 µF            ± (1.2 % + 2)                             1 nF

Frequency                            99.99 Hz to 99.99 kHz           ± (0.1 % + 1)                         0.01 Hz             Fluke 27

                                                                                                                               included accessories

                                                                                                                               TL75 test leads, alligator clips, 9 V

Recommended accessories – 77-IV Digital Multimeter                                                                             battery (installed) and manual.

                                                                                                                               Ordering information

                                                                                                                               Fluke-77-4        Digital Multimeter

                                                                                                                               Fluke-73-3        Digital Multimeter

                                                                                                                               Fluke-27-YEL      Multimeter

      i400s                  C35                           ToolPak™

AC Current Clamp             Meter Case         Meter Hanger

See page 66                                                   See page 71

For more information and detailed specifications, go to www.fluke.com/dmm

                                                                                                                                             Digital Multimeters      19
                                       Complete automotive

                                                                 diagnostic tools

                                                                 Tools designed to help                                                 Application note, literature code

                                                                              you beat the book                                         1547394:

                                                                                                                                        Beat the book

                                                      Fluke 88V Automotive Multimeter                                                   This amazing reference covers test

                                                                                                                                        procedures commonly used by

                                                      The Fluke 88V Automotive Multimeter is designed                                   experienced automotive technicians.

                                                      to help automotive professionals beat the book.                                   Covers basic troubleshooting

                                                      This DMM has more measurement functions, trou-                                    techniques and measurements using

                                                      bleshooting features and accuracy to solve virtually                              a DMM and

                                                      any problems on conventional and hybrid vehicles.                                 describes

                                                      •   Automotive test functions include dc and ac volt-                             tests for the              Beat the Book

                                                                                                                                                                   Automotive electrical diagnosis.

                                                                                                                                                                   Better diagnosis, faster repair.

                                                          age, resistance and current                                                   charging                                                                                                Application                           Note

                                                      •                                                                                                            Work safely

                                                          Min/Max recording for logging the highest and                                 system,                    This application note is intended

                                                                                                                                                                   as a guide for the professional

                                                                                                                                                                   mechanic. It describes some of

                                                                                                                                                                   the test procedures commonly

                                                                                                                                                                   used by experienced technicians.

                                                          lowest readings over time                                                     starting                   However, some of the procedures

                                                                                                                                                                   require you to take certain pre-

                                                                                                                                                                   cautions to avoid personal injury

                                                                                                                                                                   and/or damage to equipment or

                                                                                                                                                                   vehicles. Fluke cannot anticipate

                                                      •   Frequency measurements for magnetic sensors                                                              all possible precautions that you

                                                                                                                                        system, fuel               must take on all the different

                                                                                                                                                                   vehicles for which this guide is

                                                                                                                                                                   applicable. For this reason, you

                                                                                                                                                                   should thoroughly familiarize

                                                                                                                                                                   yourself with proper safety

                                                          and ac/dc frequency signals                                                                              habits and take all precautions

                                                                                                                                        and air system,            described in the vehicle’s

                                                                                                                                                                   repair manuals to avoid injury

                                                                                                                                                                   or damage.

                                                      •                                                                                                            Testing automotive

                                                          Duty Cycle for variable duty cycle signals with                               ignition                   systems with an

                                                                                                                                                                   analog/digital multimeter

                                                                                                                                                                   Perhaps the most important tool

                                                                                                                                                                   you’ll use in troubleshooting auto

                                                                                                                                                                   electrical systems is the multime-

                                                          selectable trigger slope and level                                            system, and                ter. The basic multimeter

                                                                                                                                                                   measures voltage, current and

                                                                                                                                                                   resistance, while more elaborate

                                                                                                                                                                   multimeters, such as the new

                                                                                                                                                                   Fluke 88-V, have features that

                                                      •   Pulse width for fuel injector on time measurements                                                       can check things such as

                                                                                                                                        the body                   frequency, duty cycle, pulse

                                                                                                                                                                   width, make diode tests, and

                                                                                                                                                                   even measure temperature.              Although automotive multime-          The common analog type mul-

                                                                                                                                                                      In this application note you        ters with various capabilities        timeter is not only inadequate, it

                                                      •                                                                                                            will find troubleshooting tech-        have been around for years,           can damage delicate computer

                                                          Conductance testing for secondary ignition coils                              electric/engine            niques using the high quality,         many of them didn’t have the          circuitry. Both analog meters and

                                                                                                                                                                   affordable and popular line of         scales and functions required for     test lights, due to their low inter-

                                                                                                                                                                   Fluke analog/digital multimeters       todays’ automotive applications.      nal resistance (input impedance),

                                                                                                                                                                   and automotive troubleshooting         Hybrid, electric and fuel cell        draw too much power from the

                                                                                                                                                                   accessories.  Fluke’s analog/          powered vehicles have special         device they’re testing to be used

                                                      •                                                                                                            digital combination has distinct       requirements, ones met with the       on computers. What’s more,

                                                          RPM measurements for DIS and                                                  management/                advantages over either digital         new 88-V. Now that computers          many analog meters use 9V to

                                                                                                                                                                   or analog meters alone, and            and their sensors are a part of       power the resistance test, which

                                                                                                                                                                   the accessories are designed to        everyday automobile trou-             is enough to destroy sensitive

                                                                                                                                                                   make your job easier and more          bleshooting, you need a true          digital components.

                                                                                                                                                                   profitable.                            multimeter to do the job.

                                                          conventional ignition systems                                                 cooling system.   F  r  o  m  the        Fluke  Digita         l  Library  @  www.fl                 u  ke.com/library

                                                      •   Built-in thermometer                                                          Want to read more? Download this

                                                      Fluke 73-III (see pg 19 for details)                                              and other application notes at

                                                      •   Simple interface for                                                          www.fluke.com/library

                                                          one-handed operation

                                                      •   Current measurement (A and mA)

                                                      •   Auto or manual ranging

    Features – 88V and 73                                               DMMs

                                                                                                                                     For the complete diagnostics

    Feature                                                                                    88V              73                   package and maximum value,

    Digital display with analog bargraph                                                       •                •                    pick up the 88V/A combo kit.

    Continuity for detecting opens and shorts                                                  •                •                    •  Includes Fluke 88 Series V

    Diode test for alternator testing                                                          •                •                       Automotive Multimeter

    Peak Min/Max captures intermittence as fast as 250 microseconds                            •                                     •  TL224 Heat Resistant Silicone

    Min/Max average to monitor trends in oxygen sensor values for fuel  trim                   •                                        Test Leads

    Pulse width for fuel injector on time measurements                                         •                                     •  TP220 Removable Sharp Point

    Milliamp ranges to find low current parasitic drains                                       •                                        Test Probes

    Lo-Ohms (.01 W) for low resistance sensor and coil measurements                            •                                     •  AC285 Large Jaw Alligator Clips

    Duty cycle for pulse width modulated signals                                               •                                     •  TPAK Magnetic Hanger

    RPM for ignition systems                                                                   •                                     •

    Temperature for coolant and air temperature sensors                                        •                                        80BK Temperature Probe

    Dwell for points and feedback carburetors                                                                                        •  RPM80 Inductive Pick-up

    Limited lifetime warranty                                                                  •                •                    •  Automotive Backprobe Pins

                                                                                                                                     •  Insulation Piercing Probe

                                                                                                                                     •  Packaged in a durable carrying case

    Buy accessory kits and save                                                                                                         (C800)

                                                                                                                                        Fluke 88V

                                                                                                                                        included accessories

    TLK281                                     TLK282                                TL28A               TL82                                  Test leads, 9 V battery (installed),

    Automotive Test Lead Kit   Deluxe Automotive Test Lead Kit       Automotive Test Lead Set  Automotive Pin & Socket Adapter  Set     RPM pickup, carrying case and

    See page 61                           See page 61                   See page 62            See page 63                              users manual.

    Recommended automotive accessories – 88V DMM                                                                                        Ordering information

                                                                                                                                        Fluke-88-5                    Automotive

                                                                                                                                                                      Multimeter

                                                                                                                                        Fluke-88-5/A KIT              Automotive

                                                                                                                                                                      Multimeter

    TP81 or TP82                                      TP84                                  TP88                TP40                                                                Combo Kit

    Insulation                         Oxygen Sensor Insulation         Rigid Backprobe        Automotive Back                          Fluke-73-3                    Digital Multimeter

    Piercing Probes                       Piercing Probe                      Pin Set          Probe Pin Set

    See page 63                           See page 63                   See page 63            See page 63

    For more information and detailed specifications, go to www.fluke.com/dmm

20  Digital Multimeters
                       Fluke 8845A and 8846A

6.5         Digit Precision Multimeters

                                                  Precision and versatility for                                                        Application note, literature code

                                         bench or systems applications                                                                 2547797:

                                                                                                                                       Understanding specifications

                                                       The Fluke 8845A and 8846A, 6.5 digit precision                                  for precision multimeters

                                                       multimeters have the precision and versatility to                               A solid understanding of

                                                       handle your most demanding measurements on the                                  specifications

                                                       bench or in a system.                                                           is critical

                                                       Dual display offers versatile graphical                                         when you’re     5NDERSTANDINGSPECIlCATIONS

                                                                                                                                                       FORPRECISIONMULTIMETERS

                                                       capabilities: The 8845A and 8846A feature a unique                              evaluating the                                                                                           !PPLICATION.OTE

                                                                                                                                       suitability of                                                                      $IGITALMULTIMETERSARETHEWORKHORSESOFTHE

                                                       graphical display that can reveal signal quality                                                                                                                    ELECTRONICSINDUSTRY!LMOSTALLOFTHEELECTRONIC

                                                                                                                                                                                                                           PRODUCTSWEUSEINOURPERSONALANDPROFESSIONAL

                                                                                                                                                                                                                           LIVESAREBUILTORSERVICEDUSINGMULTIMETERS

                                                                                                                                                                                                                                  $IFFERENT$--APPLICATIONSREQUIREDIFFER

                                                                                                                                       DMMs for an                                                                         ENTDEGREESOFATTENTIONTOSPECS!TECHNICIAN

                                                       issues like drift, intermittent and stability by viewing                                                                                                            CHECKINGALOGICPOWERSUPPLYCANUSEHISTRUSTY

                                                                                                                                                                                                                           BENCH$--CONlDENTLYTOVERIFYTHATTHESUPPLY

                                                                                                                                                                                                                           ISWITHINAFEWPERCENTOF6(OWEVER WHEN

                                                                                                                                                                                                                           THEJOBREQUIRESTESTINGCRITICALCIRCUITS CHECKING

                                                                                                                                       application,                                                                        PRECISIONCOMPONENTS MAKINGlNEADJUSTMENTS

                                                       the measurement data as a real time TrendPlot,™                                                                                                                     INPRODUCTION VERIFYINGCOMPLIANCEWITHINDUSTRY

                                                                                                                                                                                                                           STANDARDS ORTAKINGMEASUREMENTSOUTSIDETHE

                                                                                                                                                                                                                           CONTROLLEDENVIRONMENTOFTHELAB THENYOULLNEED

                                                                                                                                                                                                                           TOEVALUATESPECIlCATIONSCAREFULLY

                                                                                                                                       or when                                                                                    !SOLIDUNDERSTANDINGOFSPECIlCATIONSISCRITICAL

                                                       Histogram or Statistics using the unique analyze                                                                                                                    WHENYOUREEVALUATINGTHESUITABILITYOF$--S

                                                                                                                                                                                                                           FORANAPPLICATION ORWHENYOUMUSTBECONlDENT

                                                                                                                                                                                                                           THATYOURREADINGSACCURATELYREmECTREALITY4HIS

                                                                                                                                                                                                                           APPLICATIONNOTEDISCUSSESSOMEOFTHETHINKING

                                                                                                                                       you must be                                                                         BEHIND$--SPECIlCATIONSANDSPECSHEETS)T

                                                       mode.                                                                                                                                                               DElNESTHEVARIOUSELEMENTSOF$--SPECSAND

                                                                                                                                                                                                                           GIVESTIPSONHOWTOAPPLYTHEM

                                                                                                                                       confident that  3PECIlCATIONSANDTHE                &ROMTHISFORMALDElNITIONWE       MUSTSTANDlRMLYBEHINDTHEIR

                                                       Wide measurement ranges: Resistance or                                                          SPECSHEET                            CANDRAWTHECHARACTERISTICSOF     SPECSANDYOUSHOULDFULLYEXPECT

                                                                                                                                                       7HENEVERWETAKEAMEASURE
           GOODSPECIlCATIONS                  THATTHEINFORMATIONYOUARE

             Fluke 8845A                                                                                                                               MENTWITHANYMETER WERE           s #OMPLETENESSnANYFACTOR       GETTINGISACCURATEANDCOMPLETE

                                                                                                                                                       GAMBLING7EREGAMBLINGTHAT        THATIMPACTSUNCERTAINTYIS         /NTHESPECSHEET YOUSHOULD

                                                                                                                                                       THEINSTRUMENTISGOINGTOGIVEUS   COVERED INCLUDINGOPERAT
           SEEMEASUREMENTUNCERTAINTY

                                                                                                                                       your readings   THEhREALvREADING&ORTUNATELY      INGLIMITSSUCHASHUMIDITY         SPECSANDMODIlERSTHATAFFECT

                                                       current has been extended to cover the widest range                                             ITSAVERYSAFEBETTHATAQUALITY  ALTITUDE ORVIBRATION               THEUNCERTAINTY9OUWILLALSOSEE

                                                                                                                                                       MULTIMETERWILLDELIVERREADINGS     s #LARITYnALLEFFORTSSHOULDBE  OPERATINGLIMITSTHATCONSTRAIN

                                                                                                                                                       THATCOINCIDEWITHREALITY3PECIl
   MADETOMAKETHESPECIlCA
           THEENVIRONMENTINWHICHTHE

                                                                                                                                                       CATIONSQUANTIFYTHECONlDENCEOF    TIONSSTRAIGHTFORWARD                UNCERTAINTYSPECIlCATIONSWILL

                                                                                                                                                       GETTINGACCURATEREADINGSANDTHE    s /BJECTIVITYnDOESNOTATTEMPT   HOLDTRUE4HESEARESTATEDIN

                                                       possible.                                                                       accurately      RISKOFSEEINGINACCURATEREADINGS   TOMISLEADFORTHESAKEOF          NUMERICALVALUESEGHUMIDITY

                                                                                                                                                       !SPECIlCATIONSDOCUMENTIS          PROMOTION                            ORWITHREFERENCETOINTERNATIONAL

                                                                                                                                                       ACLEARLYWRITTENDESCRIPTIONOF     !WELL
WRITTENSPECIlCATION         STANDARDSSHOCKANDVIBRATION 

                                                                                                                                                       ANINSTRUMENTSPERFORMANCE         SHOULDMAINTAINTHESAMELEVEL      &IRSTLETSTAKEACLOSERLOOKAT

                                                                                                                                                       )TSHOULDQUANTIFYANINSTRU
         OFINTEGRITYASAMEDICALCHARTOR  HOWWEQUANTIFYMEASUREMENT

                                                                                                                                       reflect         MENTSCAPABILITIESOBJECTIVELY      BANKSTATEMENT-ANUFACTURERS       UNCERTAINTY

                                                       Perform 4-wire measurements easily with                                                         UNDERWELL
DElNEDOPERATING

                                                                                                                                                       CONDITIONS

                                                       two leads: Patented split terminal jacks for 2x4                                reality. This    À œ “ Ê Ì … i Ê   Õ Ž i Ê ˆ } ˆ Ì >  Ê  ˆ L À > À Þ Ê J Ê Ü Ü Ü° v  Õ Ž i ° V œ “ É  ˆ L À > À Þ

                                                       ohms function allow you to perform precise 4-wire                               application

                                                       measurements with only two leads instead of four.                               note discusses some of the thinking

                                                       Optional Kelvin leads accessories are available to                              behind DMM specifications and

                                                       enable you to establish a 4-wire connection even in                             spec sheets. It defines the various

                                                       tight spaces.                                                                   elements of DMM specs and gives

                                                       Systems capabilities: Both instruments include                                  tips on how to apply them.

                                                       an RS-232, IEEE-488 and Ethernet interface as                                   Want to read more? Go to www.

                                                       standard, with popular DMM emulation modes that                                 fluke.com/library to download this

             Fluke 8846A                               make systems integration a simple task.                                         and other application notes, or get

                                                       Software: Transfer data points from your meter to                               info specific to your industry and

                                                       your PC with the free copy of FlukeView Forms Basic.                            sign up for Fluke News publications

                                                       To customize your forms, upgrade with FVF-UG.                                   at www.fluke.com/subscribe.

Features – 8845A and 8846A

Feature                                                        8845A                                      8846A

Display                                                                           Dual VFD Dot Matrix

Resolution                                                                              6.5 Digits

Continuity / Diode Test                                                                 Yes                                            Use the built-in TrendPlot paperless chart recorder

Analytical Functions                                                   Statistics, Histogram, TrendPlot™, Limit Test                   to graphically identify the extent of drift and inter-

Math Functions                                                 Zero, Min/Max/Average, Std Dev; mx + b, dB/dBm                          mittent events in analog circuits.

USB Device Port                                                        —                                  USB memory drive port

Real Time Clock                                                        —                                  Yes

Interfaces                                             RS-232, IEEE-488.2, Ethernet, USB (with optional adapter)

Programming Languages/Emulation          Modes                         SCPI (IEEE-488.2), Agilent 34401A, Fluke 45

Safety                                                 Designed to comply with IEC 61010-2000-1, ANSI / ISA-S82.01-1994,

                                                       CAN / CSA-C22.2 No.1010.1-92 1000 V CAT I / 600 V CATII

                                                                                                                                       View results in Histogram mode to reveal stability

                                                                                                                                       or noise problems in analog circuits.

Specifications – 8845A and 8846A

                                                       8845A                                              8846A

Function*                                Range         Resolution      Accuracy* (%)    Range             Resolution  Accuracy* (%)

Voltage dc                               1000 V        100 nV             0.0035        1000 V            100 nV              0.0024

Voltage ac (freq. 300   Hz)              750 V         100 nV             0.06          1000 V            100 nV                 0.06

Resistance (2x4 wire)                    100 MΩ        100 µΩ             0.01          1 GΩ              10 µΩ                  0.01

Current dc                               10 A          100 pA             0.05          10 A              100 pA                 0.05  Handle even the most demanding measurements

Current ac (freq. 3 Hz   to 10  kHz)     10 A          1 µA               0.10          10 A              10 nA                  0.10  with high accuracy and 6.5 digit resolution.

Freq/period                              300 kHz       1 µHz              0.01          1 MHz             1 µHz                  0.01

Capacitance                              —             —                  —             1 nF to 0.1 F     1 pF                   1

Temperature RTD                          —             —                  —             -200 °C to        0.001°              0.06°    Included accessories

                                                                                        +600 °C

*Accuracy = ± (% of reading)                                                                                                           LCI Line Power Cord, TL71 Test

Size (HxWxD): 88 mm x 217 mm         x  297 mm (3.45  in x 8.54 in x  11.69 in) Weight:3.6 kg (7.9 lb)  One-year warranty            Lead Set, Spare Line Power fuse,

                                                                                                                                       Programmers Manual/User Manual

Recommended accessories – 8845A and 8846A Precision Multimeters                                                                        on CD-ROM, FVF-BASIC FlukeView

                                                                                                                                       Forms Software Basic Version.

                                                                                                                                       Ordering information

                                                                                                                                       Fluke-8845A        6.5 Digit Precision

                                                                                                                                                       Multimeter, 35 ppm

TL2X4W-PT                             TL2X4W-TWE                          884X-512M                                   FVF-UG           Fluke-8846A        6.5 Digit Precision

2x4 Wire Ohms Test Lead               2x4 Wire Ohms                    USB Memory 512M                    FlukeView Forms                              Multimeter, 24 ppm

2 mm probe tip                           Tweezer                                                                        Software Upgrade

For more information and detailed specifications, go to www.fluke.com/884X

                                                                                                                                                       Digital Multimeters                                                                                                             21
                                                                 Fluke T5 and T3

                                                              Electrical Testers

                                                              Alternatives to traditional                                          Fluke 9040

                                                                                  solenoid testers                                 Rotary Field
                                                                                                                                   Indicator

                                                                                                                                   The Fluke 9040 is

                                                              Fluke T5 Voltage, Continuity and                                     a premium phase

                                                              Current Tester                                                       rotation tester with

                                                              •  Excellent front-line troubleshooting and                          a CAT III, 600 V rat-

                                                                 measurement tool                                                  ing. The frequency

                                                              •  Available in 600 V and 1000 V models                              range is from 15 Hz

                                                              •  Digital display                                                   to 400 Hz for

                                                              •  OpenJaw™ current measurement                                      demanding appli-

                                                              •  Rotary switch selects volts, amps and ohms                        cations. The clear

                                                                 functions                                                         liquid crystal display and the holster

                                                              •  Heavy-duty test leads                                             make it suitable for rough outdoor

                                                                                                                                   applications. This instrument is sup-

                                                              Fluke T3 Voltage and Continuity Tester                               plied with three unique, expandable,

                                                              •  LED voltage indicators                                            test probes which fit most sockets.

                                                              •  Seven key voltage levels                                          For more information, visit

                                                              •  Automatically switches to continuity beeper or                    www.fluke.com/9040

                                                                 ac/dc voltage

                                                              •  Heavy-duty test leads

                                                                                                                                Fluke

                                                                                                                                1AC-II/1LAC-II

                                                                                                                                VoltAlert

                                                                                                                                The pocket-sized voltage detector

                                                                                                                                The next generation VoltAlert™ ac

                                                                                                                                non-contact voltage testers from

                                                                                                                                Fluke are easy to use—just touch

    Specifications –                                    T5 and              T3 Testers                                          the tip to a terminal strip, outlet, or

                                                                                                                                supply cord. When the tip glows

                                                              T5-1000              T5-600                    T3                 red and the unit beeps, you know

       Measure dc voltage                                        1000 V            600 V              Preset 6 V, 12 V, 24 V,   there is voltage present. Electricians,

                                                                                                      36 V, 48 V, 110 V and     maintenance, service, safety personnel

                                                                                                             220 V*             and homeowners can quickly test for

       Measure ac voltage                                        1000 V            600 V              Preset 24 V, 48 V, 120    energized circuits in the workplace or

                                                                                                      V, 208 V, 240 V, 277 V    at home. Certified up to CAT IV 1000 V.

                                                                                                             and 480 V*

       Measure ac current (average)                              100 A             100 A                     N/A                Two models to choose from:

       Measure continuity                                        < 25 W            < 25 W                    < 20,000 W         •  1AC-II – detects voltage from

       Measure resistance                                        1000 W            1000 W                    N/A                   90 V ac to 1000 V ac

       DC polarity indicator                                     Yes               Yes                       Yes                •  1LAC-II – detects voltage from

       Detachable probe tips with                                Yes               Yes                       N/A                   20 V ac to 90 V ac

       optional probe tips styles

       Safety rating                                    1000 V Overvoltage        600 V Overvoltage   1000 V Overvoltage

                                                                 CAT III           CAT III                   CAT III

       Warranty                                               Two-years            Two-years                 One-year

    *  Voltage levels will vary depending  on  country  of intended use.                                                           Included accessories

                                                                                                                                   The T5-1000 and T5-600 come with

    Buy Electrical Tester Kits and Save                                                                                            detachable probes and instruction

                                                                                                                                   sheet. The T3 has fixed test leads

                                                                                                                                   and probes.

                                                                                                                                   Ordering information

                                                                                                                                   T5-1000        1000 V Voltage,                

    T3 Tester Kit                                T5-1000 Tester Kit                      VoltAlert™ Multi Pack                                    Continuity and

    Combo kit includes:                          Combo kit includes:                     Includes five Fluke VoltAlerts.                          Current Tester

    •  Fluke T3 Voltage and                      •      Fluke T5-1000 Voltage            The special kit pricing gets you          T5-600         600 V Voltage,                

       Continuity Tester                                Electrical Tester                the fifth VoltAlert™ free. Outfit                        Continuity and

    •  Fluke VoltAlert™                          •      Fluke VoltAlert™                 your entire staff.                                       Current Tester

                                                 •      Fluke H5 Holster                                                           T3             Voltage and Continuity

                                                                                                                                                  Tester

    Recommended accessories – Electrical Testers                                                                                   T3-1AC Kit     Voltage and Continuity

                                                                                                                                                  Tester Kit

                                                                                                                                   T5-H5-1AC      Voltage,  Continuity

                                                                                                                                   Kit            and Current Tester Kit

                                                                                                                                   1AC-II 5PK     VoltAlert 5 Pack

                                                                                                                                   1AC-II         Voltage Detector

                 H5                  AC285 (T5)                  Meter Cleaner              T5 Kit           C520A                 1LAC-II        Voltage Detector

    Electrical Tester Holster      SureGrip™ Alligator Clips     Cleaning Wipes          Starter Kit         Leather Tool Case     9040           Rotary Field Indicator

       See page 70                   See page 62                 See page 71             See page 61         See page 70

    For more information and detailed specifications, go to www.fluke.com/tseries

22  Electrical Testers
                                     Fluke 1625 and 1623

         Geo Earth Ground Testers

         Advanced technology for all your earth                                                                             Brochure, literature code 2633834:

                                               ground testing applications                                                  Earth Ground Resistance:

                                                                                                                            Principles, testing methods

                                                                   The new Fluke 1620 Series Earth Ground                   and applications

                                                                   Testers not only measure ground resistance               This brochure

                                                                   using the classic ‘fall of potential test’               is a highly

                                                                   but also enable time saving testing using                                                        Principles,

                                                                                                                            informative                             testing methods

                                                                                                                                                                    and applications

                                                                   the ‘selective’ and ‘stakeless’ methods.                 collection of

                                                                   ‘Selective’ testing does not require the                 information                             Diagnose intermittent

                                                                   electrode under test to be disconnected                  about Earth                             electrical problems

                                                                   during the measurement, thus increasing                  Ground                                  Avoid unnecessary

                                                                                                                                                                    downtime

                                                                   safety. The simple ‘stakeless’ method                    Systems,

                                                                   quickly checks ground connections using                  testing                                 Learn earth ground

                                                                                                                                                                    safety principles

                                                                   two current transformers (probes) clamped                methods and

                                                                   around the ground conductor under test.                  applications.

                                                                   Offering ‘one-button’ simplicity, the 1623               Want to

                        Fluke    1623                              is an all-in-one earth ground tester, while                                     Earth Ground

                                                                                                                            read more?             Resistance

                                                                   the 1625 has extra versatility for more                  Download

                                                                   demanding applications.                                  this and other application notes at

                                                                   Earth ground resistance and soil                         www.fluke.com/library

                                                                   resistivity should be measured when:

                                                                   •     Designing earth ground systems

                                                                   •        Installing new ground system and

                                                                         electrical equipment

                                                                   •        Periodically testing ground and lightning

                                                                         protection systems

                                                                   •        Installing large electrical equipment

                                                                         such as transformers, switchgears,

                                                                         machines, etc.

                                                                   The 1623 is perfect for performing

                        Fluke    1625                              predictive maintenance checks of

                                                                   commercial and industrial applications.

                                                                   The 1625 is intended for electrical utility or

                                                                   other high frequency environments.

Features – 1625/1623 Earth Ground                                                                             Testers

Feature                                                                                             1625      1623

One-button measurement concept                                                                                 •

3- and 4-pole earth ground measurement                                                                  •      •

4-Pole soil resistivity testing                                                                         •      •

2-Pole resistance measurement ac                                                                        •      •            Included accessories

2-and 4-pole resistance measurement dc                                                                  •                   Fluke 1625 Tester: 2 test leads,

Selective testing, no disconnection of ground conductor (1 clamp)                                       •      •            2 alligator clips, and users manual.

Stakeless testing, quick ground loop testing (2 clamps)                                                 •      •

Measuring frequency 128 Hz                                                                                     •            Fluke 1625 Kit: Same as above

Earth impedance measurement at 55 Hz                                                                    •                   plus stake/reel set 4 pole, selective/

Automatic frequency control (AFC) (94 Hz to 128 Hz)                                                     •                   stakeless clamp set, and rugged

Measuring voltage switchable 20/48V                                                                     •                   carrying case.

Programmable limits, settings                                                                           •                   Fluke 1623 Tester: 2 test leads,

Continuity with buzzer                                                                                  •                   2 alligator clips, and users manual.

Dust/water resistance                                                                               IP56      IP56          Fluke 1623 Kit: Same as above

Safety rating                                                                            CAT II 300        V  CAT II 300 V  plus stake/reel set 4 pole, selective/

Battery type: 6 x AA alkaline cells                                                                                         stakeless clamp set, and rugged

Size (HxWxD): 110 mm x 180 mm x 240 mm (4.33 in x 7.08 in x 9.45 in)                                                        carrying case.

Weight (including batteries): 1623 Geo: 1.1 kg (2.42 lb); 1625 Geo: 1.5 kg  (3.31  lb)

Two-year warranty

                                                                                                                            Ordering information

                                                                                                                            Fluke-1625        Advanced GEO

Recommended accessories – 1625 and 1623 Earth Ground Testers                                                                                Earth Ground Tester

                                                                                                                            Fluke-1625 Kit        Advanced GEO

                                                                                                                                            Earth Ground

                                                                                                                                            Tester Kit

                                                                                                                            Fluke-1623        Basic GEO Earth

                                                                                                                                            Ground Tester

EI-1623                                     EI-1625             ES-162P3                              ES-162P4                            Fluke-1623 Kit        Basic GEO Earth

Selective/stakeless     Selective/stakeless              Stake/reel set                 Stake/reel set                                      Ground Tester Kit

clamp set                        clamp set               for 3 pole                     for 4 pole                          These products are for unpowered

for 1623                             for 1625            measurements                   measurements

                                                                                                                            installations measuring grounding

                                                                                                                            connections.

For more information and detailed              specifications, go to        www.fluke.com/egt

                                                                                                                                         Earth Ground Testers                              23
                             Fluke 1630 Earth

                          Ground Clamp Meter

    Measure earth ground loop resistance                                                   What is ground, and what

                          anywhere. Quickly and easily.                                    does it do?

                                                                                           The NEC, National Electrical Code,

                                                                                           defines a ground as a “conducting

                          The Fluke 1630 Earth Ground Clamp is able to measure             connection, whether intentional or

                          ground loop resistances—using the Stakeless testing method.      accidental between an electrical

                          This test technique eliminates the dangerous, and time           circuit or equipment and the earth, or

                          consuming activity of disconnecting parallel grounds, as         to some conducting body that serves

                          well as the process of finding suitable locations for auxiliary  in place of the earth.”

                          ground stakes. You can also perform earth ground tests in        When talking about grounding

                          places you have not considered before: inside buildings, on      it is actually two different subjects,

                          power pylons or anywhere you don’t have access to soil.          earth grounding and equipment

                             With the Stakeless testing method, the Fluke 1630 Earth       grounding. Earth grounding is an

                          Ground clamp is placed around the earth ground rod or            intentional connection from a circuit

                          the connecting cable. No earth ground stakes are used at         conductor usually the neutral to a

                          all. A known voltage is induced by one half of the clamp         ground electrode placed in the earth.

                          and the current is measured by the other half. The tester        Equipment grounding is to ensure

                          automatically determines the ground loop resistance at this      that operating equipment within a

                          grounding connection. Gone are the days of spending time         structure is properly grounded.

                          placing and connecting stakes for each earth ground rod on       These two grounding systems

                          your system—a major time saver.                                  are required to be separate except

                          •  Quick and easy use—no earth ground stakes are                 for a connection between the two

                             necessary                                                     systems to prevent differences in

                          •  Large, 35 mm (1.35 in) jaw opening                            potential from a possible flashover

                          •  Measures ground resistance from 0.025 Ω to 1500 Ω             from a lightning strike. The purpose

                          •  Measures ground leakage current from 0.2 mA to 30 mA          of a ground besides the protection

                          •  High and Low alarming                                         of people, plants and equipment

                          •  Automatic self calibration                                    is to provide a safe path for the

                          •  Rugged carrying case and resistance check loop included       dissipation of fault currents, lightning

                                                                                           strikes, static discharges, EMI and

                                                                                           RFI signals and interference.

                          Handy GEO Earth Ground Tester

    Earth                 ground tester for resistance measurement

                             The Handy GEO Earth Ground Tester is a rugged,

                             easy-to-use tester for three-pole ground resistance

                             measurements and two-pole ac resistance

                             measurements.

                                Earth ground resistance is measured by installing

                             earth ground test electrodes and testing with the

                             Handy GEO. Earth ground resistance measurements

                             are used to ensure safe operation and reduce power

                             quality problems. The Handy GEO is extremely

                             lightweight making it ideal to test for lightning

                             protection levels and periodic check-ups during

                             routine maintenance.

                                Two-pole ac resistance is measured to confirm low          Included accessories

                             resistance between electrical joints:                         Fluke 1630 Clamp Meter: Rugged

                             •  Fuse-to-fuse holder (to ensure there is no                 carrying case with belt, resistance

                                overheating)                                               test loop, 9 V battery and users

                             •  Bonding of ground earth connections                        manual.

                             •  Additional bonding                                         Handy GEO Tester: Rugged rubber

                             •  Cable to terminal connections                              holster with carrying belt, battery,

                             AC current can be used to confirm the low resistance          and operating instructions.

                             path in two directions simultaneously.

                                The gold standard for measuring ground resistance          Ordering information

                             using classic fall of potential as well as selective and      Fluke-1630     Earth Ground

                             stakeless methods.                                                           Clamp Meter

                                                                                           Handy GEO      Earth Ground Tester

                                                                                           Handy GEO Kit  Earth Ground Tester

                                                                                                          Kit with 25 m and

                                                                                                          50 m cable reel

                                                                                                          and two earth

                                                                                                          ground stakes

                                                                                           These products are for unpowered

                                                                                           installations measuring grounding

                                                                                           connections.

    For more information and detailed specifications, go to www.fluke.com/egt

24  Earth Ground Testers
Fluke              430 Series Three-Phase

                   Power Quality Analyzers

                               Pinpoint power problems faster,                                                        Application note, literature code

                                                   safer and in greater detail                                        2435490:

                                                                                                                      Six simple ways to reduce

                                                   The Fluke 435 and 434 Three-Phase Power Quality                    costs with a Fluke 434

                                                   Analyzers help you locate, predict, prevent and trouble-           Power Quality Analyzer

                                                   shoot problems in three- and single-phase power distri-            There are

                                                   bution systems. Troubleshooting is faster with on-screen           hundreds of

                                                   display of trends and captured events, even while back-            power quality

                                                   ground recording continues. The new IEC standards for              measurements

                                                   flicker, harmonics, and power quality are built right in to        you can take

                                                   take the guess work out of power quality.                          on electrical

                                                   •  Troubleshoot real-time:                                         systems and

                                                      Analyze the trends                                              equipment.

                                                      using the cursors and                                           These

                                                      zoom tools—even while                                           instructions

                                                      background recording                                            focus on four

                                                      continues                                                       predictive

                                                   •  AutoTrend: Every                                                maintenance

                                                      measurement you see                                             (PdM)

                                                      is always automatically                                         measurements and two power

                                                      recorded, without any setup                                     consumption measurements that

                   Fluke  435                      •  Automatic Transient                                             can help you uncover hidden costs,

                                                      Mode: Capture 200 kHz                                           protect equipment from damaging

                                                      waveform data on all                                            conditions, reduce unscheduled

                                                      phases simultaneously                                           downtime, and improve system

                                                      up to 6 kV                                                      performance.

                                                   •  Measure all three

                                                      phases and neutral:

                                                      With included four

                                                      current probes

                                                   •  Fully Class-A compliant: Conduct tests according to

                                                      the stringent international IEC 61000-4-30 Class-A

                                                      standard

                                                   •  System-Monitor: Up

                                                      to ten power quality

                                                      parameters on one screen

                                                      according to EN50160

                                                      power quality standard

                                                   •  Inrush mode: For

                                                      troubleshooting nuisance

                                                      circuit breaker tripping

                   Fluke  434                      •  Logger function:

                                                      Configure for any test condition with memory for over

                                                      400 parameters at user defined intervals

Features – 435 and 434 PQ Analyzers

Features                                                          435                           434*                  Included accessories

Measures voltage, current, dips, swells,                                                                              Fluke 435 Analyzer: Hard carry-

interruptions, harmonics, inter-harmonics,                               •                      •

flicker, power, energy, transients, frequency,                                                                        ing case with rollers, four flexible

unbalance, inrush, EN50160 overview                                                                                   current probes (i430-flex), five test

Logger function with multi-parameter logging                             •                      optional*             leads and clips, battery charger,

Mains signaling                                                          •                      optional*             FlukeView software, Power Log soft-

Memory size                                                       16 MB                         8 MB                  ware, optical USB cable, color local-

Current probes                                              3000 A flexible (4)                 40 A/400 A clamp (4)  ization set, getting started manual,

Carrying case                                               water-tight hard case with rollers  rugged hard case      users manual on CD-ROM.

Software                                                    Fluke Power Log and FlukeView®      FlukeView®

*Optional functionality can be added with upgrade     kit.                                                            Fluke 434 Analyzer: Hard carrying

                                                                                                                      case, four current probes (i400s),

                                                                                                                      five test leads and clips, battery

Recommended accessories – 435 and 434 PQ Analyzers                                                                    charger, FlukeView software, opti-

                                                                                                                      cal USB cable, color localization set,

                                                                                                                      getting started manual, users manual

                                                                                                                      on CD-ROM.

                                                                                                                      Ordering information

I5sPQ3                           i430-flex-4pk                     C435                 GPS430                               Fluke-435        Three-Phase Power

3 pack of 5 A             4 pack of 3000 A            Water-tight hard           GPS time                                            Quality Analyzer

precision current         flexible current            case with rollers      synchronization

clamps                         probes                                                          module                               Fluke-434        Three-Phase Power

For more information and detailed specifications, go                     to  www.fluke.com/pq                                        Quality Analyzer

                                                                                                                             Power Quality Analyzers          25
                                                    Fluke 43B Power

                                                    Quality Analyzer

                                                 Power quality analysis plus a                                                   Application note, literature code

                                                                        scope and a meter                                        2391563:

                                                                                                                                 The costs of poor power

                                                    The Fluke 43B Power Quality Analyzer performs the                            quality

                                                    measurements you need to maintain power systems,                             Productivity

                                                    troubleshoot power problems, and diagnose equipment                          is the key to

                                                    failures. The 43B has 20 storage locations and can store                     survival in

                                                    data as well as screens.                                                     today’s global

                                                                                                                                 competitive

                                                                                  •  NiMH battery provides                       environment.

                                                                                     extended operating time of                  Power quality

                                                                                     6.5 hours                                   problems

                                                                                  •  Voltage, current and power                  can cause

                                                                                     harmonics up to 51st                        processes and

                                                                                  •  Total harmonic distortion                   equipment to

                                                                                     (THD)                                       malfunction

                                                                                  •  Phase angle of individual                   or shut down.

                                                                                     harmonics                                   And the consequences can range

                                                                                  •  FlukeView® software with                    from excessive energy costs to

                                                                                     enhanced analysis and                       complete work stoppage. Obviously,

                                                                                     documentation capabilities                  power quality is critical.

                                                                                  •  Continuously measure volts                  To reduce your power bill, you

                                                                                     and amps cycle-by-cycle for                 need to record consumption patterns

                                                                                     up to 16 days                               and adjust the system and load

                                                                                  •  Cursors give time and date                  timing to reduce one or more of the

                                                                                     of sags and swells                          following:

                                                                                                                                 1. Actual power (kWh) usage

                                                                                                                                 2. Power factor penalties

                                                                                                                                 3. A peak demand charge structure

                                                                                                                                 Want to read more? Download this

                                                                                                                                 and other application notes at

                                                                                                                                 www.fluke.com/library

    Specifications                               –  43B Analyzer                                                              •  Watts, power

                                                                                                                                 factor, displace-

    Function                                        Fluke 43B*                                                                   ment power

    Volts/Amps/Hz                                                                                                                factor, VA and

    Volts rms                                       ± (1 % + 10 counts)                                                          VAR

    Amps rms                                        ± (1 % + 10 counts)                                                       •  Voltage

    Frequency (Hz)                                  ± (0.5 % + 2 counts)                                                         and current

    Crest Factor (CF)                               ± (5 % + 1 count)                                                            waveforms

    Sags and swells                                 ± (2 % +10 counts)                                                        •  Calculates three-

    Power                                                                                                                        phase power

    W, VAR, VA                                      ± (2 % + 6 counts)                                                           on balanced

    PF, Cos ( (DPF)                                 ± 0.04

    Harmonics and THD                                                                                                            loads from a

    Harmonics                                       ±3%                                Battery life: Rechargeable NiMH pack      single-phase

                                                                                       (charger included), 6.5 hours typical     measurement

    THD                                             ± 3%                               (continuous)

    Transient display                                                                  Shock and vibration: Mil 28800E,       •  Catch up to

    Minimum transient detection                     40 ns                              Type 3, Class III, Style B                40 voltage

                                                                                       Operating temperature: 0 ºC to 50 ºC

    Inrush current                                  ± 5 % of full scale                (32 ºF to 122 ºF)                         transients and

    Additional capabilities                                                            Case: IP51 (dust, drip waterproof)        waveform

                                                                                       Size (HxWxD): 232 mm x 115 mm x

    AutoTrend                                       •                                  50 mm (9.1 in x 4.5 in x 2 in)            distortions

    Real time scope                                 •                                  Weight: 1.1 kg (2.5 lbs)

    Ohms, diode, continuity, capacitance            •                                  Safety: IEC 1010-1, CAT III 600 V.

                                                                                       Tested and approved to UL 3111-1,

    Memory (screens/data)                           20 (screens, settings, data)       CSA C.22.2 No. 1010.1-92.

    FlukeView software and interface cable          Standard                           Warranty: Three-years on Fluke 43B,

                                                                                       one-year on accessories

    *Not including current probe specifications

                                                                                                                                 Included accessories

    Recommended accessories                      – 43B Analyzer                                                                  The Fluke 43B includes a hard

                                                                                                                                 case, voltage and current probes,

                                                                                                                                 FlukeView® software, power quality

                                                                                                                                 instructional CD, USB interface cable,

                                                                                                                                 line voltage adapter/battery charger

                                                                                                                                 and users manuals.

         i1000s                  i2000flex          TLK225                        C43                                            Ordering information

    AC Current Probe         AC Current Clamp       SureGrip Master               Carrying Case

    See page 66                  See page 66        Accessory Kit                 See page 70                                    Fluke-43B      Power Quality Analyzer

                                                                         See page 61

    For more information and detailed               specifications, go  to  www.fluke.com/pq

26  Power Quality Analyzers
   Fluke 1760 Power Quality

                                              Recorder Topas

                    Class-A compliance for the most                                                    Application note, literature code

                        demanding power quality tests                                                  2555030:

                                                                                                       What does Class A

                                                         The Fluke 1760 Three-Phase Power              mean to me?

                                                         Quality Recorder is the ideal portable        The new IEC 61000-4-30 Class A

                                                         instrument for power quality experts. It is   standard takes the guesswork out

                                                         fully compliant to IEC 61000-4-30 Class-A,    of selecting a

                                                         for advanced power quality analysis and       power quality

                                                         consistent compliance testing. Designed       instrument.

                                                         for analysis of utility and industrial power  The standard

                                                         distribution systems, in medium- and low-     IEC 61000-

                                                         voltage networks, the Fluke 1760 provides     4-30 Class A

                                                         the flexibility to customize thresholds,      defines the

                                                         algorithms, and measurement selections.       measure-

                                                         It captures the most comprehensive details    ment meth-

                                                         on user-selected parameters and allows for    ods for each

                                              trical Sa  later analysis and reporting.                 power quality

                                        Elec     fety                                                  parameter to

                                        1000 V CAT III                                                 obtain reli-

                                        600 V CAT IV                                                   able, repeat-

                                                                                                       able and

                                                                                                       comparable

•  Fully Class-A compliant: Conduct tests                •  10 MHz, 6000 Vpk waveform capture:         results. It also defines the accuracy,

   according to the stringent international                 Get a detailed picture of even the         bandwidth, and minimum set of

   IEC 61000-4-30 Class-A standard                          shortest event                             parameters. Going forward, manu-

•  GPS time synchronization: Correlate                   •  2 GB data memory: Enables detailed,        facturers can begin designing to

   data with events or datasets from other                  simultaneous recording of numerous         Class A standards, giving technicians

   instruments, with precision                              power parameters for long periods of       a level playing field to choose from

•  Flexible and fully configurable                          time                                       and increasing their measurement

   thresholds and scale factors: Allows                  •  Comprehensive software included:           accuracy, reliability, and efficiency

   user to pinpoint specific issues by                      Provides trend diagrams for root cause     on the job.

   defining the detailed criteria for detection             analysis, statistical summaries, report

   and recording of disturbances.                           writing, and real-time data monitoring

•  Highest safety rating in the industry:                   in the online mode

   600 V CAT IV/1000 V CAT III rated for                 •  Plug and play: Allows quick setup with

   use at the service entrance                              automatic sensor detection; sensors are

•  Uninterrupted power supply                               instrument powered, eliminating the

   (40 minutes): Never miss important                       need for batteries

   events—even record the beginning and                  •  Rugged field design: Insulated housing

   end of interruptions and outages, to help                and a solid state design with no rotating  Included accessories

   determine the cause                                      components, enable reliable testing

                                                            under nearly any conditions                Fluke 1760 Recorder: Voltage

                                                                                                       probes (4), current probes (4),

                                                                                                       ethernet cable for network connec-

For more information and detailed specifications,        go to www.fluke.com/pq                        tion (1), crosslink ethernet cable for

                                                                                                       direct PC connection (1), mains cable

                                                                                                       (1), GPS time sync receiver, PC soft-

                        Fluke 1650 RPM Power Recorder                                                  ware on CD-ROM, operators manuals

                                                                                                       and carrying case.

Power recorder                                                                                         Fluke 1650 Recorder: Five flexible

Fewer connections, shorter set up, less mistakes.                                                      current probes (four 1000 A and one

Patented Full-Disclosure technology captures every                                                     100 A), PAS software with report

measurement, every event, on every cycle, all the                                                      writer, ethernet cable and manual.

time—without thresholds. From simple set-ups to                                                        Ordering information

finished reports, the Fluke 1650 is the complete                                                       Fluke-1760          Without fast

solution to your portable power recording needs.                                                                           transient, voltage

The Power Recorder is all you need to record, analyze,                                                                     or current option

and document:                                                                                          Fluke-1760TR        With fast transient

•  Loading and load interaction                                                                                            option

•  Power consumption and demand                                                                        1695-Flexi Pack     Power Recorder

•  Sags, swells, harmonics or transient events                                                         These power quality recorders are

•  Ground currents                                                                                     sold exclusively through power

•  Phase relationships, including phase                                                                quality representatives. To request

   imbalance                                                                                           a demonstration, or to order, call

Multipoint                                                                                             1-888-257-9897 or email questions

For permanent installations, select Multipoint to get the same                                         to fpqsupport@fluke.com.

performance as the portable Power Recorder—simultaneously measuring all power quality                  Many configurations and accessories

parameters, as well as power consumption and harmonics.                                                are available for these recorders,

                                                                                                       go to www.fluke.com/pq for more

                                                                                                       information.

For more information and detailed specifications, go to www.fluke.com/pq

                                                                                                       Power Quality Analyzers                  27
              Fluke 1740 Series Three-

    Phase PQ Loggers Memobox

                                                       Assess power quality and                                                      Application note, literature code

                      conduct long-term studies with ease                                                                            2646555:

                                                                                                                                     Power quality recording and

                                          Compact and rugged, the Fluke 1740 Series Three-Phase                                      analysis: Techniques and

                                          Power Quality Loggers are everyday instruments for tech-                                   applications

                                          nicians who troubleshoot and analyze power distribution                                    Hooking up a

                                          systems. Capable of simultaneously logging up to 500                                       power quality      Power quality recording

                                          parameters for up to 85 days and capturing events, the                                     recorder and       and analysis: Techniques

                                                                                                                                                                            and applications

                                          Fluke 1740 Series helps uncover intermittent and hard-                                     taking days’                                                                                            Application                 Note

                                                                                                                                                        Hooking up a power quality recorder and taking                         Recording techniques

                                          to-find power quality issues. The included PQ Log soft-                                    worth of           days’ worth of data can give you a rich picture

                                                                                                                                                        of your power. In this article we’ll talk about the                    To really know your power, ideally,

                                                                                                                                                        various recording techniques available in power                        you’d want to look at every line

                                                                                                                                                        loggers and recorders—understanding the tools                          cycle to see even the smallest

                                                                                                                                                        and techniques you have available will be key to                       changes. However, since our power

                                          ware quickly assesses the quality of power at the service                                  data can give      your strategy. What should you be looking for?                         swings through more than four

                                                                                                                                                        And when does recording make sense?                                    million cycles per day, it’s impracti-

                                                                                                                                                                                                                               cal to look at tiny changes—and

                                                                                                                                                                                                                               often unnecessary. Few loads even

                                                                                                                                                                                                                               notice occasional voltage dips of

                                          entrance, substation, or at the load, according to the latest                                                                                                                        one or two cycles.

                                                                                                                                     you a rich                                                                                How long you record depends

                                                                                                                                                                                                                               somewhat on the rhythm of your

                                                                                                                                                                                                                               building. If you are working on a

                                                                                                                                                                                                                               typical commercial or light indus-

                                                                                                                                                                                                                               trial building, then a week is long

                                          EN50160 standard.                                                                                                                                                                    enough for a building to go through

                                                                                                                                     picture of your                                                                           its normal cycle. If you are work-

                                                                                                                                                                                                                               ing in a plant that runs special

                                                                                                                                                                                                                               equipment only periodically (say

                                                                                                                                                                                                                               a furnace that runs only monthly),

                                          •            Plug and play: Setup in minutes with automatic current                                                                                                                  you’ll need to be sensitive to the

                                                                                                                                     power. In this                                                                            timing of these loads.

                                                                                                                                                                                                                               Different recording techniques

                                                                                                                                                                                                                               have been developed to look at

                                                                                                                                                                                                                               small changes over relatively long

                                                                                                                                                                                                                               time periods. Many instruments

                                                       probe detection and powering                                                                                                                                            combine several techniques to

                                                                                                                                     article we’ll                                                                             improve their coverage. We’ll

                                                                                                                                                                                                                               describe the common techniques

                                                                                                                                                                                                                               and some of their pros and cons.

                                                                                                                                                                                                                               By understanding the different

                                          •                                                                                                                                                                                    techniques. you’ll be better able to

                                                       Installs inside the cabinet: Compact, fully-insulated                                                                                                                   choose an appropriate tool for the

                                                                                                                                     talk about                                                                                job at hand.

                                                       housing and accessories fit easily in tight spaces, next                      the various        Setting up a Fluke 1735 Power Logger at the service entrance for a

                                                                                                                                                        30-day load study.

                                                       to live power                                                                 recording

    Fluke 1744/1743                       •            Determines the root cause: Included PQ Log software                                              From  the           Fluke  Digital  Library                         @  w w w. f l u k e . c o m / l i b r a r y

                                                                                                                                     techniques

                                                       quickly analyzes trends, creates statistical summaries,                       available in power loggers and

                                                       and generates detailed graphs and tables                                      recorders-understanding the tools

                                          •            Monitors power for the long-term: Data can be                                 and techniques you have available

                                                       downloaded during recording without interruption                              will be key to your strategy. What

                                          •            Measure voltage with premium accuracy: IEC61000-                              should you be looking for? And

                                                       4-30 Class-A compliant voltage accuracy (0.1 %)                               when does recording make sense?

                                          •            Quickly validate quality of power: Assess power                               Want to read more? Go to www.

                                                       quality according to EN50160 power quality standard,                          fluke.com/library to download this

             Fluke 1745                                with statistical overview                                                     and other application notes, or get

                                          •            Rugged and reliable: Designed for everyday field use,                         info specific to your industry and

                                                       with no moving parts and durable, insulated case, with                        sign up for Fluke News publications

                                                       two-year warranty                                                             at www.fluke.com/subscribe.

    Features – 1740 Series PQ Loggers

    Features                                                                   1745              1744     1743

    Measurement of common power parameters: V, A, W, VA,                       •                 •                 •

    VAR, PF, energy, flicker, voltage events, and THD

    Measurement of voltage and current harmonics to the                        •                 •

    50th, unbalance, and mains signaling

    Dust/water resistance                                                      IP50              IP65 water proof

    Display                                                             LED + LCD                LED      LED

    UPS ride-through                                                      5 hours                3s       3s

    Dimensions (HxWxD)                                    282 mm x 216 mm x 74 mm                170 mm x 125 mm x 55 mm

                                                                      (11.5 in x 8.8 in x 3 in)  (6.9 in x 5.1 in x 2.2 in)          Included accessories

                                                                                                                                     Fluke 1740 Series: 4 Flexible

    Recommended accessories – 1740 Series PQ Loggers                                                                                 probes 15/150/1500/3000 A with

                                                                                                                                     2 m cable, PQ Log software, RS-232

                                                                                                                                     interface cable and RS-232-USB

                                                                                                                                     adapter, 4 black dolphin clips, test

                                                                                                                                     leads for voltages and power supply,

                                                                                                                                     color localization kit, carrying bag,

    MBX CLAMP 1 A/10 A + N                             MBX 300 POLESET                              C435                             test certificate with measurement

    3-phase+N current clamps              Pole mounting kit for 1743 and 1744                    Water-tight hard case with rollers  values, printed English manual and

    2 m cable

    For more information and detailed specifications, go to www.fluke.com/pq                                                         multi-language manual CD.

                                                                                                                                     VR101S: VR101, optical interface

    Fluke VR101S Voltage Event Recorder System                                                                                       cable, and EventView software on CD.

                                          Power tools for power quality                                                              VR101: Instruction sheet.

                                                          The VR101S is the perfect system for catching                              Ordering           information

                                                          sags, swells, transients, outages, and frequency                           Fluke-1743         Power Quality

                                                          variations on line voltage at receptacles.                                                    Logger – Memobox

                                                          The VR101S is a starter system that includes a                             Fluke-1744         Power Quality

                                                          compact VR101 event recorder, an optical inter-                                               Logger – Memobox

                                                          face cable, and EventView® software that turns                             Fluke-1745         Power Quality

                                                          your PC into a power quality reporting tool. The                                              Logger – Memobox

                                                          VR101S is covered by a one-year warranty.                                  VR101S             Voltage Event

                                                                                                                                                        Recorder System

                                                                                                                                     VR101              Voltage Event

                                                                                                                                                        Recorder

                                                                                                                                     Note: At least one VR101S is required for

    For more information and detailed specifications, go to www.fluke.com/vr101                                                      proper operation.

28  Power Quality Analyzers
                       Fluke 1735 Three-Phase

                                                Power Logger

Electrical load studies, energy consumption                                                                                 Application note, literature code

   testing, and general power quality logging                                                                               2584800:

                                                                                                                            30 Day Load Studies with

                                                                  The Fluke 1735 Three-Phase Power                          the Fluke 1735 Power

                                                                  Logger is the ideal electrician or                        Logger

                                                                  technician’s tool for conducting energy                   When a build-    30 Day Load

                                                                                                                                             Studies with the

                                                                  studies and basic power quality logging.                  ing owner        Fluke 1735

                                                                                                                                             Power Logger                                                                               Application     Note

                                                                  Set up the 1735 in seconds, with the                      wants you to     When a building owner wants

                                                                                                                                             you to add new loads to an exist-

                                                                                                                                             ing service or set of feeders, the

                                                                  included flexible current probes and                                       first thing you have to is deter-

                                                                                                                            add new loads    mine whether the existing sys-

                                                                                                                                             tem will support the new loads.

                                                                                                                                             If you have a 600 amp service

                                                                                                                                             installed in a facility, can you add

                                                                                                                                             another 100 amps of load?

                                                                  color display. The 1735 logs most                                          To answer this question you

                                                                                                                            to an existing   have to ask another one: What is

                                                                                                                                             the highest load the system car-

                                                                                                                                             ries now?

                                                                                                                                             Often, local electrical authori-

                                                                                                                                             ties will need to know these

                                                                  electrical power parameters, harmonics                    service or set   answers before they issue per-

                                                                                                                                             mits. You’ll also need a compre-

                                                                                                                                             hensive understanding of today’s

                                                                                                                                             loading to evaluate the new sys-

                                                                                                                                             tem, once installed.

                                                                  and captures voltage events.                                               To determine the existing

                                                                                                                            of feeders,      equipment’s capacity, factor in

                                                                                                                                             the incoming conductor size, the

                                                                                                                                             ratings of the equipment, and

                                                                                                                                             space for new circuits. To deter-

                                                                                                                                             mine present loading, you’ll need     The NEC specifies that:           Recording Current

                                                                                                                                             to either precisely calculate the     • The highest demand is the       and Power with the

                                                                                                                            the first thing  existing loads, or measure them.      highest demand among all          Fluke 1735

                                                                                                                                             Article 220 of the 2005               feeders.

                                                                                                                                             National Electrical Code offers       • Take the measurements when      The compact, rugged Fluke 1735

                                                                                                                                             two measurement methods for                                             Power Logger is an excellent tool

                                                                                                                                             determining existing loads and        the building is occupied.         for performing load studies.

                                                                                                                            you have to      the maximum demand the system         • Include heating or cooling      • It includes flexible current

                                                                                                                                             is likely to handle.                  loads, whichever is larger, or    probes for connecting around

                                                                                                                                             The NEC defines demand as             correct to account for these      multiple conductors or bus bars.

                                                                                                                                             the power consumption of the          loads.                            • It has a PC interface and

                                                                                                                                             loads averaged over 15-minute         • Add in any other periodic       software for downloading

                                                                                                                                             intervals.                            loads.                            measurements to a Win-

                                                                                                                            is determine     The primary NEC method is to          As always, local authorities      dows-based PC and creating

                                                                                                                                             find the maximum demand dur-          are responsible for interpreting  professional reports for your

                                                                                                                                             ing a one-year period. This only      the Code and measurements.        electrical plans.

                                                                                                                                             works if you have a year’s worth      Local regulations determine

                                                                                                                                             of demand data.                       when a load study must be per-    • It measures voltage on three

                                                                                                                                             The alternate method is to            formed, exactly what information  phases and current on three

                                                                                                                            whether          record the demand over a 30-day       is required, and the review pro-  phases and neutral.

                                                                                                                                             period and find the maximum           cess. Make sure you understand    • It records multiple parameters

                                                                                                                                             demand. This article describes        your local requirements before    that can help determine system

                                                                                                                                             the 30-day recording method,          you start a load study.           load, including voltage, current,

                                                                                                                                             known as a load study.                                                  frequency, real power (kW),

                                                                                                                            the existing                 From      the  Fluke      Digital   Library             @   www.fluke.com/library

                                                                                                                            system will

                                                                                                                            support the new loads. If you have a

•  Record power and associated parameters       •                 Improve reliability by capturing voltage                  600 amp service installed in a facil-

   for up to 45 days                                              dips and swells from load switching                       ity, can you add another 100 amps

•  Monitor maximum power demand over            •                 Easily confirm instrument setup with                      of load?

   user-defined averaging periods                                 color display of waveforms and trends                     To answer this question you

•  Prove the benefit of efficiency              •                 Measure all three phases and neutral                      have to ask another one: What is

   improvements with energy consumption                           with included 4 flexible current probes                   the highest load the system car-

   tests                                        •                 View graphs and generate reports with                     ries now? Often, local electrical

•  Measure harmonic distortion caused by                          included Power Log software                               authorities will need to know these

   electronic loads                             •                 Compact, rugged design with IP65 case,                    answers before they issue permits.

                                                                  600 V CAT III and two-year warranty                       Want to read more? Go to www.

                                                                                                                            fluke.com/library to download this

                                                                                                                            and other application notes, or get

Recommended accessories – 1735 Three-Phase Power Logger                                                                     info specific to your industry and

                                                                                                                            sign up for Fluke News publications

                                                                                                                            at www.fluke.com/subscribe

   MBX Clamp 1 A/10 A                MBX Clamp 5 A/50 A +N                                       C435

   3 precision dual range            4 precision dual range                           Water-tight hard case with rollers

   current clamps (1 A/10 A)         current clamps (5 A/50 A)

                                                Norma 4000 and 5000

                              High Precision Power Analyzers

The Norma High Precision Power Analyzers

deliver precise measurements of single or

three-phase current and voltage as well                                                                                     Included accessories

as calculation of power and other derived

values. They provides class-leading                                                                                         Fluke 1735 Logger: Four flexible

accuracy for any waveform, frequency or                                                                                     current probes (15 A/150 A/3000 A),

phase shift. Its 144 mm (5.7 in) color display                                                                              Power Log software, voltage leads

makes it easy to use both in the field and as                                                                               and clips, color localization set, PC

a table unit in labs and on test benches.                                                                                   interface cable, international ac

                                                                                                                            adapter (115/230 V, 50/60 Hz), soft

   Configurations                                                                                                           carrying case, printed English manu-

   Number of channels         NORMA 4000: 1 phase or 3 phase; NORMA 5000 and 2x3 phases                                     al and multi-language manual CD.

   Basic accuracy             0.05 % to 0.3 % ± rdg depending on options                                                    Norma 4000/5000 Analyzers:

   Sample rate                1 MHz, 1/3 MHz or 0.1 MHz depending on options                                                Test certificate with calibration

   Ranges                     Up to 100 V and 10 A or 20 A direct inputs, depending on model.    With  shunts,  transducer  values, user manual, power supply

                              or clamp accessories – up to 300 A.                                                           cable and are completely customiz-

   Mechanical power           Optional process interface 4 x speed/torque/Pmech                                             able with a variety of accessories.

   Interfaces                 RS-232, optional IEEE 488.2/1, Ethernet, USB

   Functions                                                                                                                Ordering information

   RMS values                 V/A/P/Q/S and derived values like Fundamental, THD ...                                        Fluke-1735                        Three-Phase

   Oscilloscope               Simultaneous display of up to three values on sample level

   FFT                        Up to H40 or half of sampling rate                                                                                                            Power Analyzer

   Recorder                   Display of three average values over time for trend determination                             Norma 4000 BU43                   High Precision

   Vector                     Display of Fundamental of all channels                                                                                                        Power Analyzer

                                                                                                                            Norma 5000 BU56                   High Precision

                                                                                                                                                                            Power Analyzer

For more information and detailed specifications, go to www.fluke.com/pq

                                                                                                                            Power Quality Analyzers                                                                                                           29
               Fluke 345 Power Quality

                                                  Clamp Meter

               The ideal meter for commissioning and                                        Application note, literature code

         troubleshooting modern electrical loads                                            2722823:

                                                                                            Basic power quality

                     With a bright color display to analyze the harmonic spectrum,          measurements on the go

                     a low-pass filter to remove high frequency noise, and a high           with the Fluke 345

                     EMC immunity design, the Fluke 345 is ideal for measurements           A great

                     on switching loads such as variable speed drives, electronic           introduction to

                     lighting and UPS systems. Additionally, the Hall Effect                power quality,        Basic power quality

                                                                                                                  measurements on the

                                                                                            this short            go with the Fluke 345

                     measurement system makes measurement of dc current                                                                                                                  Application  Note

                     possible without the need to break the circuit, and the internal       application                             During your day-to-day          A power quality clamp

                                                                                                                                    measurement activities,         meter like the Fluke 345

                                                                                                                                    there may be situations         combines a clamp meter,

                                                                                                                                    where you need to know          power quality meter, oscil-

                                                                                            note teaches                            more than what voltage or       loscope and data logger

                     memory enables long-term logging for analysis of trends or                                                     current is present. When        in one. This combination

                                                                                                                                    that happens, the standard      of functions coupled with

                                                                                                                                    clamp meter isn’t going to      high quality digital filtering

                                                                                                                                    get the job done. The solu-     makes it ideal for working

                                                                                            the basics of                           tion may be a power quality     with variable speed motor

                     intermittent problems.                                                                                         clamp meter such as the         drives, high efficiency light-

                                                                                                                                    Fluke 345.                      ing, and other loads using

                                                                                                                                                                    switching electronics.

                     •  AC/DC current: Clamp-on measurement of ac peak and dc               simple voltage,                         The basics

                                                                                                                                    Of course, the Fluke 345 will make the basic mea-

                                                                                                                                    surements of voltage and current to determine if

                                                                                                                                    there is something seriously wrong with the circuit

                                                                                            current,                                under test. It’s rated for use at the service entrance

                        current up to 2000 A without breaking the circuit                                                           with a 600 Volt CAT IV rating.

                                                                                                                                    Measuring voltage is as simple as using a clamp

                                                                                                                                    meter: Connect the test leads up to the voltage

                                                                                                                                    inputs, select voltage, and then read the rms volt-

                                                                                                                                    age. Current measurement is just as easy. Select

                     •                                                                      waveform,                               current, open the jaw, clamp around the wire and

                        Highest safety rating: 600 V CAT IV/1000 V CAT III rated for                                                measure. With the 2000A range and large jaw

                                                                                                                                    opening, you can evaluate most of the circuits in

                                                                                                                                    the building.

                                                                                                                                    The Fluke 345 can also measure both ac and dc

                                                                                            harmonics,                              voltage and current simultaneously, and identify

                                                                                                                                    the magnitude of each separately and combined as

                        use at the service entrance                                                                                 ac+dc true-rms. That’s helpful for checking a UPS,

                                                                                                                                    battery, and output, to make sure that the circuits

                                                                                                                                    are working correctly and the batteries are in good

                                                                                                                                    condition. A dc voltage component on the output

                                                                                            power, inrush,                          of a UPS or even an adjustable speed motor drive

                     •  Accurate measurement of parameters: Even with distorted                                                     may even be a quick indicator of a developing

                                                                                                                                    problem. For example, waveform non-symmetry

                                                                                                                                    will cause an apparent dc voltage component and

                                                                                                                                    may indicate impending failure of system output

                                                                                                                                    electronics.

                        waveforms present on electronic loads with low-pass filter          and logging

                     •  Data logging: Identify intermittent faults by logging               measurements          From  the  Fluke  Digital  Library  @  www.fluke.com/library

                        any power parameters for minutes or months, including               using the

                        harmonics                                                           Fluke 345. Learn how to read

                     •  Verify batteries: Direct measurement of dc ripple (%) for           waveforms and how and where

                        battery and dc systems                                              to use them, and then learn about

                     •  Troubleshoot harmonics: Analyze and log harmonics                   harmonics and how they distort

                        digitally or graphically                                            voltage and current.

                     •  Inrush current: Capture and analysis from 3 seconds to              Download this and other

                        300 seconds                                                         application notes at www.fluke.

                     •  Easy-to-use: Easily confirm instrument setup with large             com/library or sign up for Fluke

                        backlit color display of waveforms and trends                       News to get pertinent information on

                     •  Three-Phase power: Built in capability for balanced loads.          your industry at www.fluke.com/

                     •  View graphs and generate reports: with included Power               subscribe

                        Log software

               LH1050 and LH1060 Power Clamp Meters

                  Ideal combination of a clamp and power meter

                  The LH1050/1060 ac/dc meters are essential tools for power

                  measurement and diagnostics on switching loads such as drives and

                  high efficiency lighting. They combine the functionality of a current

                  clamp, power meter and harmonics meter in a single handheld

                  instrument that has been designed to a CAT III 600 V rating. Common       Included accessories

                  applications include:                                                     Fluke 345 Clamp Meter: Batteries,

                  •  Installing and testing of dc power systems                             pair of measuring leads, alligator

                  •  Measurement of harmonics voltage and current on industrial systems     clips, operating instructions, Power

                  •  Power and energy optimization                                          Log software, interface cable pouch,

                  LH1050 and LH1060 features:                                               and calibration certificate.

                  •  Wide range of measuring tasks possible with V, A, Hz, W, VAR, VA and   LH1050/LH1060 Clamp Meters:

                     PF in one easy to use clamp                                            Battery, pair of measuring leads,

                  •  True-rms ensures correct, accurate measurement of ac+dc and            operating instructions, and pouch.

                     distorted signals

                  •  Clear presentation of results with bargraph for dual display of V/Hz,  Recommended

                     A/Hz and PF/W                                                          accessories

                  •  Flexible applications with three-phase power capability for            WINLOG S/W       WinLOG software for

                     balanced loads                                                                          LH 1050/1060,

                  •  Easy data evaluation with ‘Smart Hold’ saving up to 7 parameters                        Analyst 2050/2060

                  •  Capture trends with record mode storing Min Max and Average values     Ordering         information

                  •  EL backlight visible in varying light levels                           LH1050           AC/DC Power

                  •  Two-year warranty                                                                       Clamp Meter

                  Additional LH1060 features:                                               LH1060           AC/DC Power

                  •  Check startup characteristics with measurement of peak voltage and                      Clamp Meter

                     current values                                                         Fluke-345        AC/DC Power

                  •  Harmonic trouble shooting with measurement of Total Harmonic                            Quality Clamp Meter

                     Distortion (THD), Distortion Factor (DF) and Crest Factor (CF)         The LH1050 and LH1060 are not

                  •  Monitor the effects of loads with dc ripple measurement                available in Canada.

    For  more  information and detailed specifications, go to www.fluke.com/clamps

30  Clamp Meters
        Fluke 360 AC Leakage

        Current Clamp Meter

     1  μA resolution leakage current measure-                                 LH2015 AC/DC

        ments with a tough, pocket sized clamp                                 True-rms Clamp Meter

                                                                               High current, large jaw clamp for

           The unique jaw design of the Fluke 360 eliminates                   industrial and utility applications

           the influence of adjacent current conductors                        The LH2015’s

           and measures leakage current down to 1 μA for                       large jaw is

           monitoring of insulation. The ergonomic design                      suitable for current

           of the Fluke 360 ensures easy measuring. The                        measurements

           measuring clamp fits into tight spaces and the                      up to 2000 A

           wide display angle clearly shows the measurement                    ac/dc on large

           result. The data hold button keeps the measured                     conductors or bus

           value on the display after removing the clamp for                   bars. The LH2015’s

           the measured conductor.                                             measurement

                       The light Fluke 360 offers the widest range             accuracy is

           of current measurement for maintenance                              unaffected by

           professionals and contractors. Use the light and                    external magnetic

           rugged Fluke 360 when it’s not possible to power                    fields or off-

           down and break the circuit.                                         center conductor

                                                                               positioning due to

           Current measurement                                                 its advanced jaw

           •           Automatic ranging within the manually selected          design. Its Display-

                       mA or A range                                           Hold feature freezes

           •           Ranges 3/30 mA and 30/60 A                              the measurement for

           •           Current resolution 1 µA/0.01 mA and                     viewing after measuring and the

                       0.01 A/0.1 A                                            Max-Hold captures the maximum

           •           Frequency range 50 and 60 Hz                            measured current.

           •           Jaw size: 40 mm (1.55 in) maximum conductor             Current clamp measurement can be

                       diameter                                                used when:

           •           Auto power off                                          •  it’s not possible to power down

           •           One-year warranty                                          equipment and break the circuit.

                                                                               •  checking the current on large

                                                                                  loads to avoid overheating of

                                                                                  conductors.

                                                                               •  measuring large dc currents in

        LH41 AC/DC Low Current Clamp Meter                                        industrial drives.

        AC/DC current clamp for low current applications                       Features:

        The compact size of the LH41 makes it ideal for making                 •  2000 ac and dc current

        general measurements on small conductors. With excellent                  measurement

        accuracy and resolution of 1 mA, the LH41 offers exceptional           •  Accurate true-rms measurement

        performance for automotive and other low current                          for distorted waveforms

        applications.                                                          •  Large 50 mm (2 in) jaw capacity

                                                                               •  Autoranging and Auto-zero

        Features                                                               •  Display-Hold and Max-Hold

        •  Easy use autoranging ac/dc leakage current                             (surge)

           measurements from 10 mA to 40 A                                     •  Two-year warranty

        •  High 1 mA current resolution for quick circuit comparison

           on sensor and control circuits

        •  Patented jaw design for high accuracy, low dc current

           measurement ensures no interference from other circuits

        •  Push button dc Auto Zero for correct measurement

           every time

        •  Battery saving auto power off function                              Included accessories

        •  ‘Carry everywhere’ pocket size, lightweight design                  Fluke 360 Clamp Meter: Soft

        •  Convenient display hold for capturing measurement in                carrying pouch and users manual.

           inaccessible spots

        •  CAT III 300 V                                                       LH41 Clamp Meter: Battery and

        •  Two-year warranty                                                   operating instructions.

                                                                               LH2015 Clamp Meter: Soft case and

                                                                               users manual.

                                                                               Ordering information

                                                                               Fluke-360       AC Leakage Current

                                                                                               Clamp Meter

                                                                               LH41            AC and DC Current

                                                                                               Clamp Meter

                                                                               LH2015          AC/DC True-rms

                                                                                               Clamp Meter

                                                                               These products are not available

                                                                               in Canada.

For  more information and detailed specifications, go to www.fluke.com/clamps

                                                                                                   Clamp Meters     31
                            Get more done with the

                                       latest Fluke tools

                                    Move up to better design and                                                Fluke 337 Premium

                    performance with Fluke clamp meters                                                         Clamp Meter

                                                                                                                •  Rugged

                                                                                                                •  CAT III 600 V

                                                            It’s never been more important to be                •  Inrush

                                                            efficient, fast, and accurate at your job.          •  Compact

                                                            Today, you need a tool that can keep up

                                                            with the demanding needs of residential,

                                                            commercial, and industrial electricians. The

                                                            Fluke 337 Clamp Meter provides you the

                                                            ability to work quickly and easily in narrow

                                                            and dark locations, and makes it possible to

                                                            keep track of your measurements for further

                                                            analysis.

                                                            The Fluke 337 is a significant

                                                            improvement from the Fluke 30 Series

                                                            clamps that were built in the mid 1990’s.

                                                            While the 30 Series was a leader in its day,

                                                            the 337 offers a design that is compact and

                                                            lightweight, and functionality that allows

                                                            you to take measurements that are more

                                                            precise.

                                                            Fluke 330 Series clamps are designed

                                                            more ergonomically with capabilities not

                                                            found in their predecessors, the Fluke 30, 31,

                                                            32, 33 and 36.

                                                            Specialty clamp meters

                                                            See page 54 for information on the NEW!

                                                            902 True-rms HVAC Clamp Meter.

                                                            See page 44 for information on the NEW!

                                                            771 Milliamp Process Clamp Meter.

    Function                        Fluke 30 Series Clamps  Fluke 337            Benefit

    Three-year warranty             Out of warranty         Three-year warranty  Lower cost of ownership

    Small body and jaws fit                                                      Fits into tight areas for

    perfectly in your hand and      —                                  •         maximum usability

    into tight places

    Frequency measurement           —                                  •         Built-in frequency counter

    Meter controls are positioned                                                Easier to use, efficient

    so current measurements                                                      measurements

    can be done with one hand       —                                  •

    (index finger on clamp

    opening lever and thumb on

    rotary switch)

    Large, backlit display is       —                                  •         Use in dark areas

    easy-to-see

    Inrush current function for                                                  Easily measure inrush

    measuring starting current for                                               current on motors, switches,

    motors, lighting, etc.          —                                  •         and circuit protectors to

                                                                                 determine if equipment can

                                                                                 work with high current levels

    Improved low current                                                         More precise measurements

    measurement accuracy            —                                  •

    from new microprocessor

    technology

    Min/Max capability              Max only                          Min/Max    Easily track your

                                                                                 measurements

    For more information and detailed specifications, go to www.fluke.com/clamps

32  Clamp Meters
                                             Fluke 337 and 322

                                                                         Clamp Meters

              Measure inrush motor starting current                                                                                          Application note, literature code

                                    the way a circuit breaker sees it                                                                        2041766:

                                                                                                                                             Making accurate inrush

                           •        Inrush current feature (selected models)                                                                 current measurements

                           •        Small body and jaws fit perfectly in your hand                                                           New high-efficiency motors require

                                    and into tight places                                                                                    better tools to evaluate and fix the

                           •        Controls positioned for one hand operation                                                               consequences of their high inrush

                           •        Accurate low current measurements                                                                        current. The Fluke 335, 336 and

                           •        Backlight available on most models                                                                       337 Clamp

                           •        Auto shut-off                                                                                            Meters are

                           •        Display hold                                                                                             designed

                           •        Safety rating: IEC 1010-2-031, CAT III 600 V                                                             to capture

                           •        Three-year warranty on 330 Series                                                                        inrush current

                                                                                                                                             accurately

                           Fluke 322 Clamp Meter                                                                                             and, most

                           •        Precise measurements with 1.8 % basic accuracy                                                           importantly,

                           •        Resolution up to 0.01 A and 0.1 V                                                                        synchronously

                           •        Measures ac current 40.00 A/400.0 A                                                                      and provide

                           •        Measures ac and dc volts to 600 V                                                                        readings that

                           •        Resistance measurement to 400 W                                                                          accurately

                           •        Continuity for quick checking of shorts                                                                  depict what

                                                                                                                                             the circuit

                                                                                                                                             protector

                                                                                                                                             experiences.

                                                                                                                                                    This application note covers

                                                                                                                                             practices to help you accurately

                                                                                                                                             and safely measure and interpret

                                                                                                                                             inrush current measurements.

Specifications – 320 and 330 Series                                                                                                          Want to read more? Download

                                                                                                                                             this and other application notes at

Fluke 320 and 330 Series Clamp Meters offer an impressive array of innovative features with                                                  www.fluke.com/library

current ranges up to 1000 A. Choose the model that matches the jobs you do.

(@23 °C ± 5 °C RH                                                                                                                            Models 333, 334, 335, 336

        0 to 90 %)         Fluke 321         Fluke 322      Fluke 333        Fluke 334        Fluke 335         Fluke 336       Fluke 337    and 337

         Range             to 400.0 A        40.00 A/       to 400.0 A                        to 600.0 A                        to 999.9 A   Operating temperature: -10 °C to 50 °C

                                             400.0 A                                                                                         (-14 °F to 122 °F)

AC                                  1.8 % + 5 counts                         2 % + 5 counts                        2 % + 5 counts

current  Accuracy                      (50 to 60 Hz)                         (50 to 60 Hz)                         (10 to 100 Hz)            Altitude: 2,500 meters

         AC response                                       Averaging                                            True-rms                     Battery life: (2) AA alkaline approximately

Inrush   Integration time           —                 —               —                                    100 mS                            150 hours continuous, automatic low battery

                                                                                                                   0 to         0 to         indicator

DC       Range                      —                 —               —          —                 —               600.0 A      999.9 A      Safety rating: IEC 1010-2-031, CAT III 600 V

current  Accuracy                   —                 —               —          —                 —               2 % + 3 counts            Temperature de-rating: Add 0.1 x specified

         Range                      400.0 V/600.0 V                                           to 600.0 V                                     accuracy for each ºC above 28 ºC or below

AC                                  1.2 % + 5 counts                         1 % + 5 counts                        1 % + 5 counts            18 ºC

volts    Accuracy                   (50 to 400 Hz)                           (50/60 Hz)                            (20 to 100 Hz)            Storage temperature: -40 ºC to 60 ºC

         AC response                                       Averaging                                            True-rms                     (-40 ºF to 140 ºF)

DC       Range                      —        400.0 V/                                         to 600.0 V                                     Models 321 and 322

volts                                        600 V

         Accuracy                   —                                            1 % + 5 counts                                              Operating temperature: -10 °C to 50 °C

         Range                         to 400.0 W           to 600.0 W                             600.0 W/6000 W                            (-14 °F to 122 °F)

Ohms     Accuracy                   1 % + 5 counts                                          1.5 % + 5 counts                                 Altitude: 2,000 meters

         Continuity                                                              < 30 W                                                      Battery life: (2) AAA carbon zinc

         Range                      —                 —               —          —                 —               —            to 400 Hz    approximately 100 hours continuous,

Hz                                                                                                                              0.5 % + 5    automatic low battery indicator

         Accuracy                   —                 —               —          —                 —               —            counts       Safety rating: IEC 1010-2-031, CAT III 600 V

MIN/MAX                             —                 —               —          —                 —               —   &