电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

61F-HSL AC100

器件型号:61F-HSL AC100
器件类别:热门应用    机电/工控/自动化   
文件大小:8291.08KB,共7页
厂商名称:All Sensors
标准:
下载文档

器件描述

控制器 level control

参数
制造商: Omron
产品种类: 控制器
RoHS:

61F-HSL AC100器件文档内容

Floatless Level Switch (Ultra High-sensitivity Type)

61F-UHS/-HSL

                                                                                                                                                                              CSM_61F-UHS_-HSL_DS_E_2_2

Ideal for Detecting Ice, Pure Water, or
Humidity

Applicable for detecting ice, pure water steam, humidity, or other
substances that conduct electricity poorly.

Two types of model available: Ultra high-sensitivity and variable
ultra high-sensitivity.

Refer to Safety Precautions for Floatless Level
Controllers.

Ordering Information

Type  Ultra high-sensitivity               Variable ultra high-
                                                  sensitivity
                                Model
                                                     Model
Ultra high- 61F-UHS
sensitivity                            61F-HSL

Note: When ordering, specify the desired operating voltage at the end of the model number.
        Example: 61F-UHS [220VAC]
                                                      Desired supply voltage

Ultra High-sensitivity Models

Use these models for sensing objects such as ice, high-purity distilled water, moisture, or other objects with low electrical conductivity.

Specifications

                       Item                           High-sensitivity 61F-UHS                        Variable high-sensitivity 61F-HSL
Supply voltage                         100, 200, or 220 VAC; 50/60 Hz                       24, 100, 110, 200, or 220 VAC; 50/60 Hz
Operating voltage range                85% to 110% of rated voltage
Interelectrode voltage                 24 VAC                                               13 VDC max.
Interelectrode current                 Approx. 1 mA AC max.                                 Approx. 1 mA DC max.
Power consumption                      3.2 VA max.
Interelectrode operate resistance      0 to approx. 1 M (see note 1)                        0 to approx. 5 M (variable)
Interelectrode release resistance      Approx. 5 M to                                       Operate resistance + 2.5 M max.
Cable length                           5 m (see note 2)                                     (see note 3)
Control output                         0.3 A, 220 VAC (Inductive load: cos = 0.4)           2 A, 220 VAC (Inductive load: cos = 0.4)
                                       1 A, 220 VAC (Resistive load)                        5 A, 220 VAC (Resistive load)
Ambient temperature                    Operating:10 to 55C
Ambient humidity                       Operating:45% to 85% RH                              Electrical: 500,000 operations min.
Insulation resistance                  100 M max. (at 500 VDC)                              Mechanical: 5,000,000 operations min.
Dielectric strength                    2,000 VAC, 50/60 Hz for 1 min
Life expectancy                        Electrical: 50,000 operations min.
                                       Mechanical: 5,000,000 operations min.
Weight                                 Approx. 210 g

Note: 1. Use 61F-UHS for detecting water leakage with high specific resistance. Connect a sensor cable between terminals 1 and 7.

        2. Two Electrodes can be connected to the 61F-HSL. Use them for an alarm, not for creating a self-holding circuit.
        3. The length when using completely-insulated, 600-V, 3-conductor (0.75 mm2) cabtire cables. Usable cable lengths will become shorter as

            the cable diameter or number of conductors becomes larger. For more details, refer to Safety Precautions for Floatless Level Controllers.

        4. It is recommended that the cable length be kept as short as possible since the Electrode circuit current is at DC micro-current level. More-
            over, the Electrodes will corrode rapidly if the current is allowed to constantly flow between the Electrodes.
            Be careful with the electrode polarity and grounding when wiring.

                                                                                                                                                                                                         1
Internal Circuit Diagrams                                                                             61F-HSL                                                                            61F-UHS/-HSL

61F-UHS                                                                                                                                                                                            Relay
                                                                                                                                                                                             To each circuit
S1 66    Operation             Rectification/                                                         S1 5
           power supply        smoothing                                                                                                                                                                          Relay
Power                                     Rectificationcircuit                  To each circuit                                                   Rectification        Constant voltage
supply                                       smoothing circuit                                                                                      smoothing circuit    circuit
                                                          Level detection                                            Operation
S2 55                                                       circuit             Relay                 Power            power supply
E3 11                                                                                                 supply
E1 77                                                            Power circuit
E2 88                                                                                                 S2 6
Tb 22
Tc 44                                                                                                        7                                    Surge-absorbing      Level detection   Power circuit
Ta 33                                                                                                                                               circuit              circuit
                                                                                                             1

            X/a                                                                                     Ground 8
                          X/c
                                                                                                      Tb 2

                                                                                                      Tc 4                                   X/c

                                                                                                      Ta 3

External Circuit Diagrams (Example)

61F-UHS                                                                         61F-HSL

            45                 Power                                                                  45                             Power
                               source                                                                                                source

         3      6                                                                                3        6

         2      7                                                                                2        7

            18                                                                                        18

         E3 E2 E1                                                                                (-)            (+)

Socket: 8PFA1 (track mounted)/                                                  Socket: 8PFA (track mounted)/
            PL08 (back connecting)                                                          PL08 (back connecting)

                                                                                                                                                                                                                         2
Connections                                                                                                                  61F-UHS/-HSL

Automatic Water Supply and Drainage Control                                                                     Ultra High-sensitivity
                                                                                                                Type

                                                                                                                        Dimensions:
                                                                                                                        Page 4

               Automatic Water Supply Control                                                                   Automatic Drainage Control

Connections                           61F-UHS                                             Connections                            61F-UHS

     Commercial Voltage                         654 3                                       Commercial Voltage                             6543
              RST                                                                                       RST

  MCCB                                                                                     MCCB

                                                       0V             U                                                                  0V         U

                                                           24 V       Control   U                                                            24 V   Control    U
                                                                       circuit                                                                       circuit

                                                           24 V                                                                              24 V

                                              Power                      U                                                           Power             U

                                              supply                                                                                 supply

                                              78 12                                                                                  78 1 2

Contac-                                   (See note.)                                     Contac-               (See
tor                                                                                       tor                   note.)

Motor                                                  PS-3S                              Motor
protection                                                                                protection
relay                       Water supply               Water                       Stop   relay                         PS-3S
                                source                   tank                      Start
                                                                         E1                                                                  Start
                                                                 E3 E2
                                                                                                                Wastewater           E1
                                                                                                                        tank E3 E2           Stop

            M            P                                                                            M         P

                                                                                                                                                    Reservoir

Note: Be sure to ground the common Electrode E3 (the                                      Note: Be sure to ground the common Electrode E3 (the
        longest Electrode).                                                                       longest Electrode).

        Connection Sockets                                                                        Connection Sockets
        8PFA1 (Front-connecting)                                                                  8PFA1 (Front-connecting)
        PL08 (Read-connecting)                                                                    PL08 (Read-connecting)

Connect terminal 2 to the contactor coil terminal.                                        Connect terminal 3 to the contactor coil terminal.

Principles of Operation                                                                   Principles of Operation

               Water supply
            P

            Pump OFF                      E1           Indicator ON                                   Pump ON                    E1  Indicator ON
                                                       Indicator OFF
            Pump ON                                                                                   Pump OFF                       Indicator OFF
                                                                                                                                           P
                                  E2                                                                                         E2                   Water drainage
                             E3                                                                                         E3

When the water level reaches E1, the pump stops and,                                     When the water level reaches E1, the pump starts and,
  when the water level reaches E2 or below, the pump                                        when the water level reaches E2 or below, the pump
  starts.                                                                                   stops.

                                                                                                                                                                  3
                                                                                                                                             61F-UHS/-HSL

Dimensions

Note: All units are in millimeters unless otherwise indicated.

61F-UHS

                                                                                              5

                                             91 72 71.2                                                                  82                  61F-UHS
                                                                                                                                          7                     101
                                                                                   3.5
                                                                                 24                                     97.5                  8PFA1
                                                                                 60
61F-HSL
                                                               5
                                                              5.6                                                       72.6       7         61F-HSL
                                        80 62 61                                                                                                               113
                                                                                                                        91
                                                                                       3.5                                                    8PFA
                                                                                 49

                                                                                                                        99.3

Electrode Holders

PS-3S/-4S/-5S

PS-3SR/-4SR/-5SR                                                                                                                             Mounting Holes

(see note)                              PF2 parallel thread                                                                                                         Used with
                                                                                                                                                                    coupling
                       9-dia. rubber (effective dia.: 58.135)

                       bushing (inner)                                                                    34 dia.

                                                                                                                                                      With
                                                                                                                                                      Mounting
                                                                                                                                                      Bracket

                                                                                                                                             65 dia.
                                                                                                                                             hole

                                                                           PS-3S (approx. 150 g)                        PS-4S (approx. 170 g) PS-5S (approx. 185 g)
                                                                           PS-3SR (approx. 155 g)                       PS-4SR (approx. 175 g) PS-5SR (approx. 190 g)

                                                                                                                                                                  Mounting Screw Holes

Note: The PS-3SR, PS-4SR, and PS-5SR have built-in resistor of 6.8 k and used for the two-wire 61F models.

PS-31                                                                                            PF1/2 Parallel thread

                                                                                                                        11 dia.              Mounting Holes

Weight: approx. 325 g

                                                       Electrode                                 Rubber
                                                       SUS304
                                                                        3                        packing
                                                                    M3
F03-31 Dust-preventive rubber cap (optional)                                                                            29.5 dia.

         Weight: approx. 20 g           Note: Standard holder construction includes three integral
                                        300-mm-long Electrodes. However, a model having
                                        1,000-mm-long Electrodes is available on request.

                                                                                                                                                                                        4
                                                                                                                                                               61F-UHS/-HSL

BF-1                                                                                                      (72)                           Two, M5 25
                                                                                                       23 8 22
                                                                                                                                         mounting screws

                                                                                                                                                              Mounting Holes

                                                              60 (48) 33 dia.                                             (20 dia.)                            26-dia.  48
                          Weight: approx. 75 g                                                                                                                 hole
                                                                                                                           (18)
                                                                                 Terminal bolt,                                402.0           Two, 6-dia. holes
                                                                                 SUS304 (M6) Nuts (M6)                             (47)

BF-3/-3R                                                          BF-3(R)        Weight
BF-5/-5R                                                                         BF-3: approx. 210 g
                                                                                 BF-3R: approx. 215 g

                                                                                                         Two, 6-dia. holes                                     Mounting Holes

                                                                                                                      R19       1               64-dia. hole            1
                                                                                                  Three, 26-dia. holes
                                                                                                                                   120
                                                   110 (90)                                                                                 90                                    90

                                                                                                                          120

                                                                                                                                                Two, 6-dia. holes

              Nut                   Two, M5 25 mounting screws                 74
              (M6)
Terminal
bolt, SUS304                                                      BF-5(R)        Weight
(M6)                                                                             BF-5: approx. 360 g
                                                                                 BF-5R: approx. 365 g
                          20 dia.
                                                                                                               Five, 26-dia. hole
                                                                                                                                                               Mounting Holes

                                                                                                                                             Two, 6-dia. hole  R13

                                    Spring washer                 110 dia. (90)                                                                 50 90          76                     90

                 23           (18)
              (49)        8 22

                                     402.0                                                                                              50                                   76
                                    (47)

                    (72)

BS-1(S)                             BS-1                                             Width across flats: 20

Weight: approx. 70 g                BS-1S
                                    BS-1S1
                                    BS-1S2                                     Terminal bolt           M18                Two, M4 P=0.7          Mounting Holes
                                                                               SUS304 (M4) P=0.7       P=1.5
                                                                                                                                                M18 P=1.5
                                                                                                                                24              (fine screw thread)

                                                                                 Nut (iron) 12                    39                            M18 P=1.5
                                                                                                                                                (fine screw thread)
                                                                                 50                        51

                                                                                                  101

                                                                                                  Width across flats: 20

                                                                               Terminal bolt               M18            Two, M4 P=0.7
                                                                               SUS304 (M4) P=0.7           P=1.5

                                                                                                                                24 dia.

                                                                                                       12         39

                                                                                 50                           51

                                                                                                  101

                                                                                                                                                                                          5
BS-1T                                     Terminal bolt                                                          61F-UHS/-HSL
                                          SUS304
                                          SUS316                                                              Mounting Holes
                                          Titanium
                                          Hastelloy B    M4 nut Width between
                                          Hastelloy C    SUS304 flats: 20.5

                                                                                                   Two, M4**

          Hastelloy                                                                                           24 dia. M18 P=1.5
          titanium                                                                                                       (fine screw thread)

                                                                                                   *This nut is made of Teflon
                                                                                                   **A connecting nut made of Hastelloy B, Hastelloy

                                                                                                   C, or titanium is not supplied with two M4 screws
                                                                                                   and thus has no holes for such screws.

Material           SUS304                 SUS316                           Titanium                HAS B                                HAS C
Weight             Approx. 55 g           Approx. 55 g                     Approx. 45 g            Approx. 65 g                         Approx. 60 g

PH-1                                                     PH-2

(Approx. 140 g with a 1-m cord)                          (Approx. 235 g with a 1-m cord)

                                                                                                   Two, 6-dia. holes PVC resin (black)

                                   Resin

                                                                           26 dia. 27 dia. 5 dia.

          19 dia.                                                                                                                                                Two-core
                                                                                                                                                                 cable
                                                        Single-core
                                                        cable

                 Cable OD: Vinyl 5.0 dia., Hypalon 6.5 dia.                                        Cable OD: Vinyl, Hypalon 6.8 dia.

            Note: Cable is supplied in lengths of 1, 5, 10, 15, 20, 30, 40,                                           F03-14 5P for five poles
                      50, 60, 70, 80, 90, or 100 meters.
                                                                                                                                                   Five, 7 dia.
Electrode Separators

          F03-14 1P for one pole                        F03-14 3P for three poles

                         6.5 dia.                                     Three, 7 dia.

                                                                             20                               20

                  28 dia.                                          41                                                       46
          Weight: Approx. 15 g                           Weight: Approx. 30 g                                     Weight: Approx. 30 g

Safety Precautions

Refer to Safety Precautions for All Level Controllers.

Precautions for Correct Use

Short Wiring in Electrode Circuit

Keep the wires connecting the Controller to Electrode Holders as
  short as possible. If long leads are used, the floating capacity of the
  leads, and abnormal surges or noise in the Electrode circuit can
  cause malfunctions.

The thicker the cables, the shorter the permitted wiring length. The
  length of the cable connecting the Controller and Electrode is
  specified in the Controller datasheet as a guideline assuming that a
  600-V VCT 0.75-mm2, 3-core cabtire cable is used. Test results
  indicate that the actual wiring length using VCT 3.5-mm2, 3-core
  cable laid over the ground is 50% of the specified length for
  general-purpose applications and 80% of the specified length for
  long-distance applications. When selecting cable specifications,
  remember that the wiring length is further decreased for
  underground cables and larger diameter cables because of the
  increased floating capacity with the ground.

          ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
          To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                            In the interest of product improvement, specifications are subject to change without notice.

                                                                                   6
                                                       Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                            Application Considerations

SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

       Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

       Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
           safety equipment, and installations subject to separate industry or government regulations.

       Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                       Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

OMRON Corporation                                                                                                                                        2010.6
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                                                   (c)Copyright OMRON Corporation 2010 All Right Reserved.
http://www.ia.omron.com/
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved