Floatless Level Controller                                                                                       61F

Automatic Water Supply and Drainage                                                                              RC
Control
                                                                          A pump is usually connected to a contactor, which in turn is con-
   Ideal for level control of any conductive liquid                       nected to the Controller contact outputs. The Level Controller would
                                                                          automatically operate the pump, to control the liquid level in the
   Both general-purpose and panel-use models                              tank.
   available
                                                                          However, in practice, with only two electrodes, ripples on the sur-
   Incorporates an arrester for surge and induced                         face of the liquid cause the Controller to jump and start, shortening
   lightning protection                                                   pump (and other equipment) life. This problem can be solved by ad-
                                                                          ding another electrode to form a self-holding circuit. The additional
   Wide range of models: Long-distance, high- and                         electrode, E2, is connected in parallel with E1, as shown below.
   low-sensitivity, two-wire, etc.

   LED indicator for quick operation check

   Conforms to EMC/IEC standards
   (61F-GP-N/-N8/-GPN-V50)

   UL/CSA approved (61F-GP-N8/-GPN-V50)

Operating Principle

Unlike ordinary level switches that use a float for level detection, the
61F Floatless Level Controller uses electrodes to electrically detect
the liquid level. The following figures illustrate this simple operating
principle.

8 VAC X  Relay
            X

Relay contacts
       ba

Magnetic contactor (To)      E1                                                       X             a2 c2
                         E3                                                                     X          b2
                                                                                                             E1
         No current flows between E1 and E3.                                   Relay contacts
                                                                                       b1 a1       E3 E2
When electrode E1 is not in contact with the conductive liquid, the                      c1                      PUMP OFF
electrical circuit is open, and no current flows between electrodes                                              PUMP ON
E1 and E3.                                                                Magnetic contactor (To)

Consequently, relay X does not operate. Relay X's NC contacts             As shown in the above figure, when the holding circuit relay is ener-
(normally closed, b in the figure) remain closed. However, when liq-      gized, contact a2, its NO contact, is closed. The electrical circuit
uid is supplied to the tank, so that the liquid contacts or immerses      made through the liquid and the electrodes is then retained by E2
E1, the circuit closes. Relay X operates, and electrical devices con-     and E3, even when the liquid level falls below E1, as long as contact
nected to the NO (normally open, a in the figure) contacts of the         a2 is closed.
relay begin operation.
                                                                          When the liquid level falls below E2, the circuit made through the
8 VAC X  Relay                                                            electrode circuit opens, which de-energizes relay X, thus closing
            X                                                             the NC contact of X.

Relay contacts                                                            Operating as simply as it does, possible applications of the Float-
       ba                                                                 less Level Controller are virtually endless. Not only liquid level con-
                                                                          trol is possible, but such applications as leakage detection, object
Magnetic contactor (To)       E1                                          size discrimination, and many other problems may be solved by one
                         E3                                               of the reliable 61F Floatless Level Controllers.

                Current flows between E1 and E3.
61F                                                                                                                                            61F

Model Selection

  Basic Configuration of 61F Conductive Level Controller

To use a 61F Conductive Level Controller, the 61F itself, Electrode Holders, and Electrodes are required.

     Basic configuration                      61F                  Select from the capability, function, and size to suit the application.
                                              Electrode Holders    Refer to the following Controller selection guidelines.
                                                                   Select from the characteristics, application examples, and shape.
                                                                   Refer to page 66 for cautions about the Electrode Holders.

                                              Electrodes           Select according to operating conditions and shape.
                                                                   Refer to pages 65 to 67 for cautions about the Electrodes.

Typical Application Example

                                                                   LED Indicator
                                                                   Convenient for maintenance and checking operations

61F Controller                                                     Relay Unit
Cermet wire is used in the transformer to prevent                  Incorporates a transistor-based control circuit and output relay. One to
accidents by short-circuiting.                                     five Relay Units are used, depending on the application.

                                                                         Electrode Holder/Electrodes
                                                                         Many materials, sensitivities and mounting variations are available.

     M: Electrical Motor                                   Water
     P: Fluid Pump                                         supply
                                                           source
                                           M
                                                   P

Ordering Information

61F Controller Selection Guide by Installation Method

Standard Model                                                     Plug-in Model
                                                                   Compact Plug-in Model

When there is sufficient mounting space.                         When using socket mounting.
When monitoring operation through LEDs.
61F                                                                                                                                                                 61F

61F Controller Selection Guide by Application

            Item                                                  G                                                               G1
                                   Automatic water supply and drainage control
                                                                                                    Automatic water                             Automatic water
                                                                                                     supply (idling                             supply (abnormal
                                                                                                       prevention)                               shortage alarm)

Function    Automatic pump         Water supply                Water drainage                       Water supply Water tank                     Water supply Water tank
            operation
            (constant water                        P             Pump                                                 P                                     P
            level)                                               ON
                                        Pump                     Pump                                        Pump                                 Pump
                                        OFF                      OFF                                         OFF                                  OFF

                                        Pump                         P                                       Pump                                 Pump
                                        ON                                                                   ON                                   ON

            Water level       ---                                                                                         Water supply                         Water tank
                                                                                                                          source
            indication
            abnormal alarm

                                                                                                            Pump OFF      Short-                        BL  Short-
                                                                                                            (idling pre-  age                               age
                                                                                                            vention)

                                                                                                                          BL

Appearance                                                     Compact Plug-in Model

                              Standard Model                                                        Standard Model                                      Plug-in Model

                                                                              61F-GP-N
                                                                              (Pages 18 to 20, 53)

                              61F-G                                                                 61F-G1                                              61F-G1P
                              (Pages 6 to 10, 52)                                                   (Pages 6 to 8, 11 to 12, 52)                        (Pages 25 to 28, 54)

                                                                              61F-GP-N8
                                                                              (Pages 21 to 24, 53)

            Item                                                 G2                                                           G3
             Automatic pump        Automatic water supply and drainage control                              Automatic water supply and
             operation                                                                                      drainage control (abnormal
             (constant water                (abnormal water increase alarm)
             level)                                                                                             filling/shortage alarm)
             Water level
Function     indication                                    Water supply       Water drainage                Water supply                                Water drainage
             abnormal alarm
                                                                           P  Pump                                          P
                                                                              ON
                                                                   Pump                                                   Pump                          Pump
                                                                   OFF        Pump                                        OFF                           ON
                                                                   Pump       OFF
                                                                   ON                                                     Pump                          Pump
                                                                                     P                                    ON                            OFF

                                                                                                                                                            P

                                                           BL                                                                     B LH
                                                                                                                                          Full
                                                               Upper
                                                               limit

                                                                                                                                  B LL          Short-
                                                                                                                                                age

Appearance                         Standard Model                             Plug-in Model                               Standard Model

                                   61F-G2                                     61F-G2P                                     61F-G3
                                   (Pages 6 to 8, 13, 52)                     (Pages 25 to 26, 29, 30, 54)                (Pages 6 to 8, 14, 53)
61F                                                                                                                                                                   61F

            Item                                  G4                                                                             I                                     Alternative
             Automatic pump    Water source level indication,                                            Liquid level indication and alarm                         operation of two
             operation        prevention of pump idling due                                           ---
             (constant water   to water shortage, automatic                                                                                                               pumps
             level)                                                                                                                                               ---
                                  water supply control, and                                                                                                       ---
                              indication of water level in tank
                                                                                                                                                                    Compact plug-in Model
Function                      Elevated water tank

                                                           Water       Water supply souse
                                                           supply

                                                                    P

                                                  Pump
                                                  OFF

                                                   Pump                Pump
                                                   ON                  ON

                                                                       Pump
                                                                       OFF

            Water level       Elevated water tank                                                                        B LH
            indication
            abnormal alarm    B LH                                                                                             Upper
                                     Full                                                                                      limit

                                                                                  Water supply souse                                       Middle

                                                                       B LH                                              LM
                                                                                  Upper
                                                                                  limit                                        Lower
                                                                                                                               limit
                                                                                                                         B LL

                              B LL         Short-
                                           age

                                                                 B LL  Lower
                                                                       limit
                              Standard Model
Appearance

                                                                                                      Standard Model                               Plug-in Model

                                                                                                                               61F-IP                             61F-APN2
                                                                                                                               (Pages 25 to 26, 31, 54)           (Pages 34 to 43, 54)

                                                                                                      61F-I
                                                                                                      (Pages 6, 17, 52)

                              61F-G4
                              (Pages 6 to 8, 15, 53)

Related Products              Surge Suppressor Unit (for                                              61F-WLA Water                                61F-GPN-V50 Water
                              protecting against induced                                              Leakage Alarm                                Leakage Detector
Relay Unit for standard       voltage) (Pages 44, 54)                                                 (Pages 68 to 71)                             (Pages 68 to 71)
models (Page 8)
61F                                                                                                                                  61F

  Accessories

Electrode Holders

Applications  General        Applications       Liquid with low       Applications           Applications    Applications    Applications
              applications   where only a       specific              where high             where high      where high      where
              such as water  small space is     resistance            mounting               temperature/    corrosion       distance to the
              supply lines   available                                strength is            high pressure   resistance is   water surface
                                                                      required               conditions are  required        is long
                                                                                             severe
Models        PS-3S/-4S/-5S  PS-31              BF-1                  BF-3/-4/-5                             BS-1T           PH-1/-2
Appearance    (Two-wire                                                                      BS-1
              models are                                                                                                     PH-2
              also
              available.)

                                                                                                             SUS

                                                                                                                  Hastelloy          PH-1
                                                                                                                  titanium

Electrodes

Sets of Electrodes, connecting nuts, lock nuts, and spring washers are available. When ordering individual parts, refer to page 45.

Applications Purified city water,               Purified city water,  Sodium hydroxide,      Sea water, ammonia   Acetic acid, dilute
                     industrial water,          industrial water,     acetic acid, dilute    water, nitric acid   sulfuric acid,
                     sewage                     sewage, dilute        sulfuric acid, dilute                       sea water
                                                alkaline solution     hydrochloric acid
Models        F03-60-SUS201                                           F03-60 HAS B           F03-60 HAS C         F03-60 Titanium
                                                F03-60-SUS316
                                                                           F03-11
Others                                                                                         Model

                                          Item

Protective Cover
  (for PS or BF electrode holders)

Spring Clamp                                                          F03-12
(for PS electrode holders)
                                                                      F03-14 1P (for 1 pole)
Electrode Separators (for preventing long electrodes from             F03-14 3P (for 3 poles)
contacting with each other)                                           F03-14 5P (for 5 poles)
61F-Gj                                                                                                             61F-Gj

Specifications

  Standard Models

Specifications

Items                  General-purpose High-tempera- Long-distance High-sensitiv- Low-sensitiv-                    Two-wire
                                                                                                                   Controller
                       Controller          ture Controller Controllers ity Controllers ity Controller

                       61F-j (TDL)           61F-jT          61F-jL 2KM         61F-jH             61F-jD            61F-jR
                        (see note          (see note 1)        (for 2 km)     (see note 1)       (see note 1)      (see note 1)
                          1 and 2)
                                                             61F-jL 4KM
                                                               (for 4 km)
                                                              (see note 1)

Controlling materials  For control of or-  For control of    For control of   For control of     For control of    For control of
and operating          dinary purified     ordinary puri-    ordinary puri-   liquids with high  liquids with low  ordinary puri-
conditions             water or sewage     fied water or     fied water in    specific resis-    specific resis-   fied water or
                       water               sewage water      cases where      tance such as      tance such as     sewage water
                                           in cases where    the distance     distilled water    salt water, sew-  used in com-
                                           the ambient       between sew-                        age water, acid   bination with
                                           temperature is    age pumps and                       chemicals, al-    Two-wire Elec-
                                           high.             water tanks or                      kali chemicals    trode Holder
                                                             between receiv-                                       (incorporating a
                                                             er tanks and                                          resistor of
                                                             supply tanks is                                       6.8 k)
                                                             long or where
                                                             remote control
                                                             is required.

Supply voltage         100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz

Operating voltage      85% to 110% of rated voltage
range

Interelectrode         8 VAC                                                  24 VAC             8 VAC
voltage

Interelectrode         Approx. 1 mA AC max.
current

Power consumption Approx. 3.2 VA max. (One unit)

Interelectrode         0 to approx. 4 k    0 to approx.      0 to approx.     Approx. 15 k       0 to approx.      0 to approx. 1.1
operate resistance                         5 k               1.8 k (for       to 70 k            1.8 k             k
                       Approx. 15 k to                       2 km)            (see note 5)
Interelectrode                             Approx. 15 k to   0 to approx.                        Approx. 5 k to    Approx. 15 k to
release resistance                                           0.7 k (for       Approx. 300 k                        
                                                             4 km)            to  

                                                             4 k to   (for
                                                             2 km)
                                                             2.5 k to  
                                                             (for 4 km)

Cable length           1 km max.           600 m max.        2 km max.        50 m max.          1 km max.         800 m max.
(see note 3)                                                 4 km max.

Control output         2 A, 220 VAC (Inductive load: cos = 0.4)
                       5 A, 220 VAC (Resistive load)

Ambient temperature Operating: --10C to 55C (--10C to 70C for 61F-jT)

Ambient humidity       Operating: 45% to 85% RH

Insulation resistance 100 M min. (at 500 VDC)
(see note 4)

Dielectric strength    2000 VAC, 50/60 Hz for 1 min.
(see note 4)

Life expectancy        Electrical: 500,000 operations min.
                       Mechanical:5,000,000 operations min.

Note: 1. The j in the model name represents G, G1, G2, G3, G4, and I.

2. The suffix "TDL" attached to the model name represents models designed for tropical regions (storage humidity of 45 to 90% RH).

3. The length when using completely-insulated, 600-V, 3-conductor (0.75 mm2) cabtire cables. Usable cable lengths will become
    shorter as the cable diameter or number of conductors becomes larger.

4. The insulation resistance and dielectric strength indicate values between power terminals and Electrode terminals, between power
    terminals and contact terminals, and between Electrode terminals and contact terminals.

5. Possible to use with 15 k or less, however, this may cause reset failure.
61F-Gj                                                                                                                                           61F-Gj

Internal Circuit Diagrams

The schematic diagrams shown below typify the internal connections of the various 61F models. The designations Ta, Tb, and Tc (sometimes
referred to collectively as "U") may occur more than once in a product, however, the "a" terminal is always an NO contact, a "b" terminal is an NC
contact, and the "c" terminal is the common terminal.

61F-G                                              61F-GT                                                61F-GL

             0V          24 V  61F-11      U                 0V             24 V  61F-11T     U                    0V          24 V  61F-11L     U
                               Relay Unit                                         Relay Unit                                         Relay Unit
           100, 110                                        100, 110                                              100, 110
           or 120 V      8V                                or 120 V         8V                                   or 120 V      8V
           200, 220                                        200, 220                                              200, 220
           or 240 V                                        or 240 V                                              or 240 V

                                       U                                                  U                                                  U

                     U                                               U                                                     U

Ta Tc                    Tb        E2          E1          Ta Tc            Tb        E2          E1             Ta Tc         Tb        E2             E1

S0                   S1        S2          E3              S0        S1           S2          E3                 S0        S1        S2          E3

61F-GH                                             61F-GD                                                61F-GR

(See note.)                                                  0V                   61F-11D         U                0V          24 V  61F-11R         U
                                                                                  Relay Unit                                         Relay Unit
             0V                61F-11H     U               100, 110         24 V                                 100, 110
                         24 V  Relay Unit                  or 120 V                                              or 120 V
           100, 110                                        200, 220                                              200, 220
           or 120 V                                        or 240 V         8V                                   or 240 V      8V
           200, 220
           or 240 V      24 V

                                                                                                                                                            U

                                       U                                                  U

                                                                     U                                                     U

                     U                                                                                           Ta Tc         Tb                       E1

Ta Tc                    Tb        E2          E1          Ta Tc            Tb        E2             E1

                                                           S0           S1        S2          E3                 S0        S1        S2          E3

S0                   S1        S2          E3
61F-Gj                                                                                                              61F-Gj

Note: The 61F-11H relay de-energizes when there is water present across the Electrodes, whereas the 61F relay energizes when there is
          water present across the Electrodes.
          Also, the terminal connections of those Controllers provided with LED indicators differ from those which have no indicators.

61F-11 Relay Units

           Item                 61F-11       61F-11T            61F-11L          61F-11H       61F-11D          61F-11R
                                        Provided           Provided         Not provided  Provided         Not provided
Interchangeable with ---
general-purpose
model (61F-11)

Color of band on           ---          Red                Yellow           Blue          Black            Green

name plate

61F-11                                  61F-11T                             61F-11L       E      SS         S

        E   SS             S                     E  SS             S

        8      76          5       4             8     76          5     4                8         76      5          4

           8 V 24 V 24 V                            8 V 24 V 24 V                            8 V 24 V 24 V

                 Tr1 Tr2        X                      Tr1 Tr2        X                                 Tr1 Tr2     X

            x                   x                   x                 x                          x                  x

9 10 11             1      2       3    9 10 11        1           2     3                9 10 11       1        2     3

Tb2 Ta2 Tc2 Tc1 Ta1 Tb1                       Tb2 Ta2 Tc2 Tc1 Ta1 Tb1                     Tb2 Ta2 Tc2 Tc1 Ta1 Tb1

61F-11H                            Tr2  61F-11D                             61F-11R

(see note)

        E   SS             S                     E  SS             S                      E      SS         S

        8      76          5       4             8     76          5     4                8         76      5          4

           24 V 24 V 24 V                           8 V 24 V 24 V                            8 V 24 V 24 V

                 Tr1 Tr2        X                      Tr1 Tr2        X                                 Tr1 Tr2     X

            x                   x                   x                 x                          x                  x

9 10 11             1      2       3    9 10 11        1           2     3                9 10 11       1        2     3

Ta2 Tb2 Tc2 Tc1 Tb1 Ta1                 Tb2 Ta2 Tc2 Tc1 Ta1 Tb1                           Tb2 Ta2 Tc2 Tc1 Ta1 Tb1
61F-Gj                                                                                                                                          61F-Gj

Connections
61F-G

Automatic Water Supply and Drainage Control

1. Water Supply                                                                2. Drainage

Water supply                                                                                                        Water drainage

                   P             (U indicator ON)                                                       E1                   (U indicator ON)

    Pump OFF E1                                                                                                     Pump ON

                 Pump ON  E2     (U indicator OFF)                                                      E2                   (U indicator OFF)
                             E3
                                                                                                                    P

                                                                                                                E3 Pump OFF

Connect electromagnetic switch coil terminal A to Tb.                         Connect the electromagnetic switch coil terminal A to Ta.

The pump stops (indicator ON) when the water level reaches E1                The pump starts (indicator ON) when the water level reaches E1

    and starts (indicator OFF) when the water level drops below E2.                and stops (indicator OFF) when the water level drops below E2.

                          200-VAC power supply  61F-G               Transformer
                                   RST
                                                                0V
                                                            100 V    24 V  61F-11       U

                                                                           Relay Unit

                          MCCB                      200 V                       U
                                                                     8V

                                                                     U

                                                    Ta                     Tc       Tb              E2          E1

                                                                    S0         S1          S2           E3

                                                                                    (See note 1)

                                                                                                                 *

                                                    Rated voltage:

                                                A   S0--S1: 100 or 110 or 120 VAC
                                                    S0--S2: 200 or 220 or 240 VAC

                                 Electromagnetic switch                 Water tank

                          THR                                                                   E1  PS-3S
                                                                                    E2
                                                                                                         Stop
                                                                                          E3             Start

                                                    Water supply source

                                         P
                                 M

Note: 1. The diagram shows the connections for the water supply. When draining, change the connection from terminal Tb to terminal Ta.
          2. Be sure to ground terminal E3.
61F-Gj                                                                                                                                                    61F-Gj

61F-GR                                                                     2. Drainage

Two-wire Automatic Water Supply and Drainage Control
1. Water Supply

        Water supply          (U indicator ON)                                                                               Water drainage
                              (U indicator OFF)
                           P                                                                                                           (U indicator ON)
                                                                                                                               Pump ON
              Pump OFF E1
                                                                                                                                       (U indicator OFF)
        Pump ON  E2
                    E3                                                                                                                P
                                                                                                                           Pump OFF

Connect electromagnetic switch coil terminal A to Tb.                     Connect the electromagnetic switch coil terminal A to Ta.

The pump stops (indicator ON) when the water level reaches E1             The pump starts (indicator ON) when the water level reaches E1

    and starts (indicator OFF) when the water level drops below E2.            and stops (indicator OFF) when the water level drops below E2.

                                                                           Note: 1. The two-wire models require two cables for connecting
                                                                                         the 61F-GR and electrode holders and three electrodes.

                                                                                     2. The electrode holders must be special ones for two-wire
                                                                                         models. (The resistance R is built into the electrode
                                                                                         holder for the two-wire models.)

                 200-VAC power supply    61F-GR              Transformer
                          RST
                                                         0V
                                                      100 V      24 V  61F-11R              U
                                                                       Relay Unit

                                                 200 V           8V

                 MCCB

                                                                       U
                                                                                                                        U

                                                 Ta                    TC       Tb                             E1

                                                             S0            S1                  S2  E3

                                                                                (See note 1)

                                                 Rated voltage:

                                         A       S0--S1: 100 or 110 or 120 VAC
                                                 S0--S2: 200 or 220 or 240 VAC

                              Electromagnetic switch             Water tank
                                                                                         R
                                                                                                   PS-3SR
                 THR                                                                        E1
                                                                                                        Stop
                                                                                E2                      Start
                                                                                      E3
                                            Water supply source

                                      P
                              M

Note: 1. The diagram shows the connections for the water supply. When draining, change the connection from terminal Tb to terminal Ta.
          2. Be sure to ground terminal E3.
61F-Gj                                                                                                                                        61F-Gj

61F-G1

Application 1:Automatic Water Supply Control with Pump Idling Prevention

                  Water tank                                                                   The pump stops (U2 indicator ON) when the water level reaches

                  E1'            (U1 indicator ON)                                                E1 and the pump starts (U2 indicator OFF) when the water level
                                 (U1 indicator OFF)                                               in the tank drops below E2.
                       E2'
                                                                                              When the level of the water supply source drops below E2', the
                  Short-
                                                                                                  pump stops (U1 indicator OFF). Pump idling is prevented and the
                  age       E3'                                                                   alarm sounds.

                  BL                                                                           Insert a pushbutton switch (NO contact) between E1' and E3 as

        Water     Water supply                                                                    shown by the dotted line. When starting the pump or after
        supply    source                                                                          recovering from a power failure, if the water supply source level
                                                                                                  has not yet reached E1', press the pushbutton switch to start the
        P                        (U2 indicator ON)                                                pump by momentarily short-circuiting E1' and E3. When the
                                                                                                  pump stops during normal operation subsequent to an alarm
        Pump OFF  E1                                                                              issued for a low water level (e.g., the water level does not reach
                                                                                                  E2'), do not press the pushbutton switch.

        Pump ON                            (U2 indicator OFF)

                          E2
                              E3

                                        61F-G1

                  200-VAC power supply                                 Transformer

                                 RST                           0V                                 U1

                                                                                      61F-11
                                                                       24 V Relay Unit
                                                       100 V

                                                                       24 V           61F-11      U2
                                                                                      Relay Unit

                                                       200 V

                       MCCB                                                     8V
                                                                                                        U1

                                                                                      U2          U1
                                                                                                     Tc2 Tb2
                                                                   U2

                                                       S0              Tb1 Ta1

                                                               S1  S2           E3        E2  E1            E2'  E1'
                                                                                                                 (E4)

                                                                                                            B Alarm                   Push-
                                                                                                                                      button
                                                       Rated voltage:                                                                 switch
                                                       S0--S1: 100 or 110 or 120 VAC
                                                       S0--S2: 200 or 220 or 240 VAC                                                  PS-3S

                                      Electromagnetic

                                      switch           *

                            THR                                                                   Water tank                      E1

                                              Water supply                                                                   E2
                                              source                                                                   E3

                                      MP                                   E1'
                                                                   E3 E2'

Note: Be sure to ground terminal E3.
61F-Gj                                                                                                                                      61F-Gj

61F-G1

Application 2: Automatic Water Supply Control with Abnormal Water Shortage Alarm

        Water supply Water tank  (U2 indicator ON)                         The pump stops (U2 indicator ON) when the water level reaches

                           P                                                  E1 and starts (U2 indicator OFF) when the water level drops
                                                                              below E2.
             Pump OFF E1
                                                                           If the water level drops below E4 for any reason, the pump stops

        Pump ON        E2        (U2 indicator OFF)                           (U1 indicator OFF) and the alarm sounds.
                         E4      (U1 indicator OFF)
           BL                E3                                           Insert a pushbutton switch (NO contact) between E3 and E4.

             Shortage                                                         When starting the pump or after recovering from a power failure,
                                                                              if the water level has not yet reached E4, press the pushbutton

                                                                                       switch to start the pump by short-circuiting E3 and E4. If the

                                                                                       pump stops upon releasing the pushbutton switch, keep

                                                                                       pressing the pushbutton switch.

                                                    61F-G1

                       200-VAC power supply                         Transformer

                                       RST                  0V                                 U1

                                                                          61F-11
                                                                    24 V Relay Unit
                                                     100 V

                                                                    24 V  61F-11               U2
                                                                          Relay Unit

                                                     200 V

                                 MCCB                               8V
                                                                                            U1

                                                                          U2               U1

                                                                U2

                                                     S0             Tb1 Ta1                    Tc2 Tb2

                                                            S1  S2  E3                 E2  E1              E1'

                                                                                                   E2'     (E4)

                                                                                                   B

                                                                                           Alarm

                                                                  *                                                             Pushbutton
                                                                                                                                switch
                                            Electromagnetic
                                            switch                                                                                  PS-4S

                                                        Rated voltage:
                                                        S0--S1: 100 or 110 or 120 VAC
                                                        S0--S2: 200 or 220 or 240 VAC

                                 THR                                                           Water tank                   E1
                                                                                                                          E2
                                                     Water supply source                                         E3 E4

                                            MP

Note: Be sure to ground terminal E3.
61F-Gj                                                                                                                                                                        61F-Gj

61F-G2

Automatic Drainage Control and Water Supply with Abnormal Water Increase Alarm

1. Drainage                                                                                        2. Water Supply

             BL                 Water drainage                                                                  Water supply                      Upper   LB
                                             (U1 indicator ON)                                                                                     limit
             Upper   E4                      (U2 indicator ON)                                                               P                            (U1 indicator ON)
              limit                                                                                                                                       (U2 indicator ON)
                                 Pump ON                                                                                               E4
                         E1                                                                                     Pump OFF E1

                         E2                 (U2 indicator OFF)                                                  Pump ON                                   (U2 indicator OFF)
                            E3  Pump OFF
                                                                                                                                           E2
                                        P                                                                                                     E3

Connect the electromagnetic switch terminal (T phase) to Ta1.                                     Connect the electromagnetic switch terminal (T phase) to Tb1.

The pump starts (U2 indicator ON) when the water level reaches                                    The pump starts (U2 indicator OFF) when the water level

    E1 and stops (U2 indicator OFF) when the water level drops                                         reaches E2 and stops (U2 indicator ON) when the water level
    below E2.                                                                                          rises to E1.

If the water level reaches E4 for any reason, the alarm sounds                                    If the water level reaches E4 for any reason, the alarm sounds

    (U1 indicator ON).                                                                                 (U1 indicator ON).

                                                      61F-G2 for drainage control

                                200-VAC power supply            0V             Transformer

                                     RST                                       24 V       61F-11       U1
                                                                                          Relay Unit
                                                                100 V

                                                                                          61F-11
                                                                               24 V Relay Unit
                                                                                                       U2

                                                                200 V

                             MCCB                                              8V
                                                                                               U2

                                                                               U2                      U1

                                                                       S0      Ta1 Tc1 Tb1 Ta2

                                                                                                           Tc2

                                                                           S1  S2         E3       E2  E1       E4

                                                                               (See note 1)            B

                                                           Rated voltage:
                                                           S0--S1: 100 or 110 or 120 VAC
                                                           S0--S2: 200 or 220 or 240 VAC

                                                               *

                                     Electromagnetic
                                     switch

                                                                                                                    Reservoir

                                THR

                                                      Water supply                        PS-4S
                                                      source

                                          MP                                    E1 E4
                                                                       E3 E2

Note: 1. The diagram shows the connections for the water supply. When draining, change the connection from terminal Tb1 to terminal Ta1.
          2. Be sure to ground terminal E3.
61F-Gj                                                                                                                                                                                       61F-Gj

61F-G3

Automatic Water Supply and Drainage Control with Abnormal Water Shortage Alarm and Water Tank Repletion

1. Water Supply                                                                                     2. Drainage

              Water supply            Upper   LH B                                                                               B LH                                                   Water drainage
                                       limit
               P                              (U1 indicator ON)                                                                          Upper                                                      (U2 indicator ON)
                                                                                                                                                                                        Pump ON
                                E1                                                                                   (U1 indicator ON)                       limit
        Pump OFF                                                                                                                                                                                    (U2 indicator OFF)
                                              (U2 indicator ON)                                                                                                         E1              Pump OFF
                                  E2
                                                                                                                                                                        E2                      P

        Pump ON                               (U2 indicator OFF)
                                              (U2 indicator OFF)
                 E3                                                                                                  (U3 indicator OFF)
                   E4                         LL  B                                                                                                              LL         E4
                       E5 Lower limit                                                                                                                     B

                                                                                                                                                                        Lower limit E5

Connect electromagnetic switch coil terminal A with Tb.                                           Connect the electromagnetic switch coil terminals A with Ta.

The pump stops (U2 indicator ON) when the water level reaches                                     The pump starts (U2 indicator ON) when the water level reaches

    E2 and starts (U2 indicator OFF) when the water level drops                                         E2 and stops (U2 indicator OFF) when the water level drops
    below E3.                                                                                           below E3.

If the water level rises to E1 for any reason, the upper-limit                                     If the water level rises to E1 for any reason, the upper-limit

    indicator turns ON and the alarm sounds (U1 indicator ON).                                          indicator turns ON and the alarm sounds (U1 indicator ON).

If the water level drops below E4 for any reason, the lower-limit                                  If the water level drops below E4 for any reason, the lower-limit

    indicator turns ON and the alarm sounds (U3 indicator OFF).                                         indicator turns ON and the alarm sounds (U3 indicator OFF).

                                                     61F-G3 for water supply

                 200-VAC power supply                                            0V  Transformer
                          RST                                          100 V
                                                                                         24 V 61F-11
                                                                                               Relay Unit            U1

                                                                                         24 V 61F-11
                                                                                               Relay Unit U2

                                                                       200 V             24 V 61F-11                 U3
                                                                                               Relay Unit

                 MCCB                                                                    8V

                                                                                                                             U2

                                                                                         U1 U3           U1      U3

                                                                   U2

                                                        Ta             Tc            Tb      B1          B2      Lc      E1      E3                          E5

                                                                   S0         S1         S2                  LH      LL      E2      E4

                                                                                             Alarm                                                                   *

                                                                                                 Upper           Lower
                                                                                             B limit PL PL limit
                                                                   (See note 1)

                                                                                                 Power           Power
                                                                                                 source          source

                                                     A

                                                  Electromagnetic  Rated voltage:
                                                  switch           S0--S1: 100 or 110 or 120 VAC
                                                                   S0--S2: 200 or 220 or 240 VAC

                                                                                                                                                                 PS-5S

                 THR                                                                                                         E1 E2                                          Water repletion
                                                                                                                                     E3                                      Water shortage
                                                                                                             Water tank
                                                                                                                                         E4
                                                        Water supply source                                                                  E5

                                              MP

Note: 1. The diagram shows the connections for the water supply. When draining, change the connection from terminal Tb to terminal Ta.
          2. Be sure to ground terminal E5.
61F-Gj                                                                                                                                                                                                              61F-Gj

61F-G4

Water Source Level Indication, Prevention of Pump Idling Due to Water Shortage, Automatic Water Supply Control, and Indica-

tion of Water Level in Tank

Insert four Electrodes in the water supply source and five                                                      The pump stops (U5 indicator ON) when the water level reaches

Electrodes in the elevated water tank.                                                                                                      E5 and starts (U5 indicator OFF) when the water level drops

The lower-limit indicator for the water supply source remains ON                                                   below E6.

    while the water source level is below E3 (U2 indicator OFF).                                                 If the water level reaches E4 for any reason, the tank repletion

When the water level rises to E2, the lower-limit indicator turns                                                  indicator for the elevated tank turns ON (U4 indicator ON).

    OFF (U2 indicator ON) and the pump is ready for operation.                                                    Insert a pushbutton switch (NO contact) between E2 and E8 as

When the water level reaches E1, the upper-limit indicator turns                                                                          shown by the dotted line. When starting the pump and after
                                                                                                                                            recovering from a power failure, if the water source level has not
    ON (U3 indicator ON).                                                                                                                   yet reached E2 (U2 indicator OFF), press the pushbutton switch
                                                                                                                                            to start the pump by momentarily short-circuiting E2 and E8.
The water-shortage indicator for the elevated tank remains ON
                                                                                                                                            When the pump stops during normal operation subsequent to an
while the water level in the elevated tank is below E7. The

indicator turns OFF (U1 indicator ON) when the water level rises                                                                            alarm issued for low water level (i.e., the water level has not

to E7.                                                                                                                                      reached E3), do not press the pushbutton switch.

                      61F-G4

                                         0V                       24 V 61F-11 Relay Unit U5

                                     100 V                        24 V 61F-11 Relay Unit U1

                                     200 V

                              MK3P          0V                    24 V 61F-11 Relay Unit U2
                              Relay         U2                    24 V 61F-11 Relay Unit U3
                                                                  24 V 61F-11 Relay Unit U4
                                     X

                                  100 V

                                                                  8V

                                  200 V         X                 U4           U3   X U1 U5 X                U4                             U3               U2 U5

200-VAC power supply          U1
                 RST

MCCB                              LL1           LL2               LH1          LH2      BL1          BL2     BH1                            BH2      E4      E3      E2          E1
                                         S0           S1                                                                                                                 E5
                                                                           S2       Tc          TC2       B       TA                             E8      E7      E6

                              Elevated tank waterLL1LL2           LH1      LH2          BL1     BL2          BH1 BH2
                                shortage
                                       Water supply source                                                                                                                           Pushbutton
                                          lower limit                                                                                                                                switch
                                                    Elevated tank
                                                       repletion
                                                                  Water supply source
                                                                     upper limit
                                                                               Elevated tank
                                                                                  water shortage
                                                                                             Water supply source
                                                                                                lower limit
                                                                                                          Elevated tank
                                                                                                             repletion
                                                                                                                       Water supply source
                                                                                                                          upper limit

             Electromagnetic                    *
             switch

              Rated voltage:                                                                                                                     Water tank                                     PS-5S
              S0--S1: 100 or 110 or 120 VAC
        THR   S0--S2: 200 or 220 or 240 VAC                                                                                                                                                 E4     Water repletion
                                                                                                                                                                                                   OFF
                               Water supply                                             PS-4S                                                                                     E5               ON
                               source                                                                                                                                        E6
                                                                                                                                                                 E8 E7                          Water shortage
                                                              E8
                                                                                   Upper limit
                    P
             M                                                         E2  E1      ON
                                                                  E3               OFF

                                                                                   Lower limit

Note: 1. Be sure to ground terminal E8.
61F-Gj                                                                                                                  61F-Gj

  Connection with Three-phase Four-line Circuit

When supplying power from N-phase to the Controller in three-phase four-line circuit, refer to the following diagrams.
Line voltage (R-S, S-T, or R-T): 380 or 415 VAC
Phase voltage (N-R, N-S, or N-T): 220 or 240 VAC

61F-Gj, 220 or 240 VAC

Water Supply

        Power source                         Transformer
        380 or 415 VAC

          R S TN*

                                             24 V          61F-11          U

                                                           Relay Unit

                                                 8V

                                         Ta                Tc          Tb             E2         E1

                                             S0                S1             S2          S3

                                                                                                    *

                                         Rated voltage:

                                      A  S0--S2: 220 or 240 VAC

        Electromagnetic switch                             Water tank

                                                                                  E1      Stop
                                                                                          Start
                                                                       E2
                                      Water supply source                   E3

                P
        M

Note: Be sure to ground terminal E3.
61F-I                                                                                                                                            61F-I

61F-I

Liquid Level Indication and Alarm

       B LH Upper                                  (U1 indicator ON)                                  When the water level drops below E2, the lower-limit indicator
                     limit                         (U1 indicator OFF)
                                       E1                                                                 turns ON and the alarm sounds (U2 indicator OFF).
                                                   (U2 indicator ON)
             LM Middle                             (U2 indicator OFF)                                  When the water level reaches E2, the alarm turns OFF and the

                     Lower                 E2                                                             intermediate indicator turns ON (U2 indicator ON).
       B LL limit                              E3
                                                                                                       When the water level rises to E1, the upper-limit indicator turns

                                                                                                          ON and the alarm sounds (U1 indicator ON).

                                                   61F-I

       200-VAC power supply                                                Transformer
                      RST
                                                       0V                  24 V      61F-11           U1
         MCCB                                          100 V
                                                                                     Relay Unit
                                                        200 V
                                                                           24 V      61F-11           U2
                                                                                     Relay Unit

                                                                           8V

                                                          U2                     U1          U2
                                                              Tc                     U1
                                                                                                  L1
                                                                           B         L3       L2

                                                                       S0        S1      S2  E3           E2  E1

                                                                           Intermediate

                                                          Alarm B                PL PL PL Lower *

                                                                                   Upper limit limit

                                                               Rated voltage:                                                   PS-3S
                                                               S0--S1: 100 or 110 or 120 VAC
                                                               S0--S2: 200 or 220 or 240 VAC

                                                                                                      Water tank            E1  Upper alarm
                                                                                                                  E3 E2            Intermediate
                                                          Water supply source
                                                                                                                                Lower alarm

                                                   MP

Note: Be sure to ground terminal E3.
61F-GP-Nj                                                                                                            61F-GP-Nj

  Compact Plug-in Models (11-pin Type)

Specifications

            Item       General-pur-       High-tempera-      Long-distance      High-sensitiv-      Low-sensitiv-        Two-wire
                            pose          ture Controller      Controllers      ity Controller      ity Controller      Controller
Controlling materials                                                                                61F-GP-ND
and operating           Controller          61F-GP-NT          61F-GP-NL          61F-GP-NH                            61F-GP-NR
conditions                                                   2KM (for 2 km)      (see note 1)      For control of
                         61F-GP-N                                                                  liquids with low  For control of
                                                               61F-GP-NL                           specific resis-   ordinary purified
                                                             4KM (for 4 km)                        tance such as     water or sew-
                                                                                                   salt water, sew-  age water used
                       For control of     For control of     For control of     For control of     age water, acid   in combination
                       ordinary purified  ordinary purified  ordinary purified  liquids with high  chemicals, alka-  with Two-wire
                       water or sew-      water or sewage    water in cases     specific resis-    li chemicals      Electrode
                       age water          where operating    where the dis-     tance such as                        Holder (incorpo-
                                          ambient temper-    tance between      distilled water                      rating a resistor
                                          ature is high.     sewage pumps                                            of 6.8 k)
                                                             and water tanks
                                                             or between re-
                                                             ceiver tanks and
                                                             supply tanks is
                                                             long or where
                                                             remote control
                                                             is required.

Supply voltage         24, 100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz
                       85% to 110% of rated voltage
Operating voltage
range                  8 VAC

Interelectrode         Approx. 1 mA AC max.                                     Approx.            Approx. 1 mA AC max.
voltage                                                                         0.12 mA AC
                                                                                max.
Interelectrode
current

Power consumption      Approx. 3.2 VA max.
Interelectrode
operate resistance     0 to approx.       0 to approx.       0 to approx.       Approx. 10 k       0 to approx.      0 to
                       4 k                4 k                1.3 k (for         to approx.         1.3 k             approx. 2 k
Interelectrode                                               2 km)              40 k
release resistance     Approx. 15 k to Approx. 15 k to       0 to approx.       (see note 4)       Approx. 4 k to    Approx. 15 k to
                                                             0.5 k (for                                             
                                                             4 km)              Approx. 100 k
                                                                                to  
                                                             4 k to   (for
                                                             2 km)
                                                             0.5 k to  
                                                             (for 4 km)

Response time          Operate: 80 ms max.
                       Release: 160 ms max.
Cable length
(see note 2)           1 km max.          600 m max.         2 km max.          50 m max.          1 km max.         800 m max.
Control output                                               4 km max.

Ambient temperature    1 A, 250 VAC (Inductive load: cos = 0.4)
Ambient humidity       3 A, 250 VAC (Resistive load)
Insulation resistance
(see note 3)           Operating: --10C to 55C (--10C to 70C for high-temperature controller)
Dielectric strength
(see note 3)           Operating: 45% to 85% RH
Life expectancy
                       100 M min. (at 500 VDC)

                       2000 VAC, 50/60 Hz for 1 min.

                       Electrical: 100,000 operations min.
                       Mechanical:5,000,000 operations min.

Note:  1. The relay in the 61F-GP-NH de-energizes when there is water present across the Electrodes, whereas the relay in the 61F-GP-
           N8HY energizes when there is water present across the Electrodes.

       2. The length when using completely-insulated, 600-V, 3-conductor (0.75 mm2) cabtire cables. Usable cable lengths will become
           shorter as the cable diameter or number of conductors becomes larger.

       3. The insulation resistance and dielectric strength indicate values between power terminals and Electrode terminals, between power
           terminals and contact terminals, and between Electrode terminals and contact terminals.

       4. Possible to use with 10 k or less, however, this may cause reset failure.
61F-GP-Nj                                                                                                                                                        61F-GP-Nj

Internal Circuit Diagrams                             61F-GP-NH                                                                      61F-GP-NR
61F-GP-N/-NT/-NL/-ND
                                                    Power supply
Power supply                                                             24 V Control circuit                                        Power supply
                    24 V Control circuit                                  8V                                                                              24 V Control circuit
                     8V                                                                                                                                    8V
                                                                                                U
                      U                          U                                                                U                                                 U           U

39        4  5 11 10 1 7 6 8                                    39                     4 5 11 10 1 7 6 8                                 39 4                    5  11 10 1

S0 S1 E3 E1 Ta1 Tc1 Tb1 Ta2 Tc2 Tb2                            S0 S1 E3 E1 Ta1 Tc1 Tb1 Ta2 Tc2 Tb2 S0 S1 E3                                                      E1 Ta1 Tc1 Tb1

Note: When applying a self-holding circuit, short between terminals 5 and 6 and use terminal 7 as E2.

Connections

61F-GP-N

Automatic Water Supply and Drainage Control                                            2. Drainage
1. Water Supply

             Water supply                                                                                                                Water drainage

                                P                Indicator ON                                                                 E1                  Indicator ON

                 Pump OFF E1                                                                                                             Pump ON

             Pump ON                      E2     Indicator OFF                                                                E2                  Indicator OFF
                                             E3
                                                                                                                                            P

                                                                                                                                     E3 Pump OFF

Connect electromagnetic switch coil terminal A to terminal 1.                         Connect the electromagnetic switch coil terminal to terminal 11.

The pump stops when the water level reaches E1 (indicator ON)                         Pump starts when the water level reaches E1 (indicator ON) and

    and starts when the water level drops below E2 (indicator OFF).                        stops when the water level drops below E2 (indicator OFF).

                                                 200-VAC power supply                  61F-GP-N
                                                       RST
                                                                                            8765
                                                                      MCCB
                                                                                                               U                         4

                                                                                                      0V          24 V Control circuit U

                                                                                                                  8V

                                                                                                        200 V                 U

                                                                                                      3                                  9

                                                                                       10 11 1 2

                                                                                                                                     (See note 1
                                                                                                                                     below.)

                                                                            Contactor  (See note 2
                                                                                       below.)

                                                        THR                            Water tank                             PS-3S
                                                    M
                                                                                 Water supply source                      E1      Stop
                                                                            P                                       E2            Start
                                                                                                               E3

Note: 1. The diagram shows the connections for the water supply. When draining, change the connection from terminal 1 to terminal 11.
          2. Be sure to ground terminal 4.
61F-GP-Nj                                                                                                               61F-GP-Nj

  Connection with Three-phase Four-line Circuit

When supplying power from N-phase to the Controller in three-phase four-line circuit, refer to the following diagrams.
Line voltage (R-S, S-T, or R-T): 380 or 415 VAC
Phase voltage (N-R, N-S, or N-T): 220 or 240 VAC

61F-GP-Nj 220 or 240 VAC

                                              61F-GP-N

                                                   8765

                                                         U             4

           Power source                            0V       24 V Control circuit U
           380 or 415 VAC                                    8V
            R S TN*                             220 or
                                                240 V       U
                             Source voltage:
                             between 3 and 9  3                        9

                                              10 11 1 2

           A                                                           (See note 1)

           Electromagnetic switch

                                                                       Stop          *(See note 2 )
                                                                       Start
                                                  Water       E1
                                                  tank
                                                         E2
                      Water supply source                          E3

                   P
           M

Note: 1. The diagram shows the connections for the water supply. When draining, change the connection from terminal 1 to terminal 11.
          2. Be sure to ground terminal 4.
61F-GP-N8j                                                                                                                     61F-GP-N8j

  Compact Plug-in Models (8-pin Type)

Specifications

       Item       General-pur-      Long-distance                High-sensitivity     Low-sensitivity        Two-wire               Variable
                pose Controller       Controllers                   Controllers          Controller         Controller            Sensitivity
                                                                                                                                  Controller
                   61F-GP-N8         61F-GP-N8L                    61F-GP-N8H           61F-GP-N8D         61F-GP-N8R
                  61F-GP-N8Y        2KM (for 2 km)                61F-GP-N8HY                                                  61F-GP-N8-V50
                   (see note 1)                                    (see note 1)
                                     61F-GP-N8L
                                    4KM (for 4 km)

Controlling     For control of or-  For control of or-           For control of liq-  For control of liq-  For control of or-  For control of
materials and   dinary purified     dinary purified              uids with high       uids with low        dinary purified     cases where
operating       water or sewage     water in cases               specific resis-      specific resis-      water or sewage     variable sensitiv-
conditions      water               where the dis-               tance such as        tance such as        water used in       ity control is re-
                                    tance between                distilled water      salt water, sew-     combination with    quired such as
                                    sewage pumps                                      age water, acid      Two-wire Elec-      detection of froth
                                    and water tanks                                   chemicals, alkali    trode Holder (in-   on the surface of
                                    or between re-                                    chemicals            corporating a re-   a liquid, control
                                    ceiver tanks and                                                       sistor of 6.8 k)    of soil moisture
                                    supply tanks is                                                                            content, or
                                    long or where re-                                                                          detection of de-
                                    mote control is                                                                            gree of water
                                    required.                                                                                  pollution

Supply voltage 24, 100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz                                                           24, 110, 220 or
                                                                                                                               240 VAC;
                                                                                                                               50/60 Hz

Operating       85% to 110% of rated voltage
voltage range
                8 VAC                                            24 VAC               8 VAC                                    24 VAC
Interelectrode
voltage         Approx. 1 mA AC max.                             Approx.              Approx. 1 mA AC max.                     Approx. 3 mA
                Approx. 3.5 VA max.                                                                                            AC max.
Interelectrode                                                   0.4 mA AC max.
current
                0 to approx.        0 to 1.3 k (for              Approx. 15 k to 0 to approx.              0 to approx.        0 to 50 k
Power           4 k                 2 km)                        approx. 70 k 1.3 k                        2 k                 (Variable)
consumption                         0 to 0.5 k (for              (see note 4)
                Approx. 15 k to     4 km)
Interelectrode                                                   Approx. 300 k to Approx. 4 k to           Approx. 15 k to     Operating
operate                             4 k to                                                                 
resistance                          (for 2 km)                                                                                 resistance
                                    0.5 k to                                                                                   +50 k max.
Interelectrode                      (for 4 km)
release
resistance

Response time   Operate: 80 ms max.
                Release: 160 ms max.
Cable length
(see note 2)    1 km max.           2 km max.                    50 m max.            1 km max.            800 m max.          50 m max.
Control output                      4 km max.

Ambient         1 A, 250 VAC (Inductive load: cos = 0.4)
temperature     3 A, 250 VAC (Resistive load)
Ambient
humidity        Operating: --10C to 55C
Insulation
resistance      Operating: 45% to 85% RH
(see note 3)
                100 M min. (at 500 VDC)

Dielectric      2000 VAC, 50/60 Hz for 1 min.
strength
(see note 3)

Life expectancy Electrical: 100,000 operations min.
                           Mechanical:5,000,000 operations min.

Note:  1. The relay in the 61F-GP-N8H/-N8Y de-energizes when there is water present across the Electrodes, whereas the relay in the
           61F-GP-N8HY energizes when there is water present across the Electrodes.

       2. The length when using completely-insulated, 600-V, 3-conductor (0.75 mm2) cabtire cables. Usable cable lengths will become
           shorter as the cable diameter or number of conductors becomes larger.

       3. The insulation resistance and dielectric strength indicate values between power terminals and Electrode terminals, between power
           terminals and contact terminals, and between Electrode terminals and contact terminals.

       4. Possible to use with 10 k or less, however, this may cause reset failure.
61F-GP-N8j                                       61F-GP-N8H                                                            61F-GP-N8j

Internal Circuit Diagrams                     Power supply                                         61F-GP-N8R
                                                                      24 V Control circuit
61F-GP-N8/-N8L/-N8D/-N8HY                                                                        Power supply
                                                                        24 V                                            24 V Control circuit
Power supply                                                                                                             8V
                      24 V Control circuit
                       8 V (see note)

                                                                                                 2

  Note: 24 V for the 61F-GP-N8HY.             61F-GP-N8-V50

61F-GP-N8Y                                    Power supply
                                                                   24 V Control circuit
Power supply                                                         24 V
                        24 V Control circuit

                          8V

                                                                                            342
61F-GP-N8j                                                                                                                    61F-GP-N8j

Connections
61F-GP-N8

Automatic Water Supply and Drainage Control                                2. Drainage
1. Water Supply

Water supply                                                                                                  Water drainage

                   P     Indicator ON                                                               E1                     Indicator ON

    Pump OFF E1                                                                                               Pump ON

Pump ON      E2          Indicator OFF                                                                    E2               Indicator OFF
                E3
                                                                                                              P

                                                                                                              E3 Pump OFF

Connect electromagnetic switch coil terminal A to terminal 2.             Connect the electromagnetic switch coil terminal A to terminal 3.

The pump stops when the water level reaches E1 (indicator ON)             The pump starts when the water level reaches E1 (indicator ON)

    and starts when the water level drops below E2 (indicator OFF).            and stops when the water level drops below E2 (indicator OFF).

             200-VAC power supply                               61F-GP-N8
                   RST
                                                                     2         1              8           7
                                  MCCB
                                                                                                 U

                                                                           0V     8V

                                                                        200 V     24 V Control circuit U

                                        (See note 1                     U
                                        below.)

                                                                     3         4              5           6

                                   Contactor         (See note 2                          E1  PS-3S
                         THR                         below.)                        E2
                                                                               E3                  Stop
                                                           Water tank                              Start

                                                     Reservoir

                      M                 P

Note: 1. The diagram shows the connections for the water supply. When draining, change the connection from terminal 2 to terminal 3.
          2. The ground terminal must be grounded.
61F-GP-N8j                                                                                              61F-GP-N8j

  Connection with Three-phase Four-line Circuit

When supplying power from N-phase to the Controller in three-phase four-line circuit, refer to the following diagrams.
Line voltage (R-S, S-T, or R-T): 380 or 415 VAC
Phase voltage (N-R, N-S, or N-T): 220 or 240 VAC

61F-GP-N8j, 220 or 240 VAC

                                       Power source
                                       380 to 415 VAC

                                         R S TN*

                                           6               5                            4            3

                                        U Control       24 V
                                               circuit

                                              U            8V

                                                                          Transformer

                                        7               8                 1                       2

                                     A

                                                                         *

            Electromagnetic switch

                                                              Water tank       E1          Stop
                                        Water supply source                                Start
                                                                          E2
                                                                                    E3

                    P
            M

Note: Be sure to ground terminal 1.
61F-GjP                                                                                                               61F-GjP

  Plug-in Models

Specifications

       Item              General-purpose                Long-distance         High-sensitivity             Low-sensitivity
                              Controller                  Controllers            Controllers                   Controller
                                                                                  61F-G1PH                     61F-G1PD
                                61F-G1P                  61F-G1PL                 61F-G2PH                     61F-G2PD
                                61F-G2P                  61F-G2PL                   61f-IPH                     61F-IPD
                                                                                 (see note 1)
                                 61F-IP                   61F-IPL
                                                        (see note 2)

Controlling materials    For control of ordinary    For control of ordinary   For control of liquids with  For control of liquids with
and operating            purified water or sewage   purified water in cases   high specific resistance     low specific resistance
conditions               water                      where the distance be-    such as distilled water      such as salt water, sew-
                                                    tween sewage pumps                                     age water, acid chemi-
Supply voltage                                      and water tanks or be-                                 cals, alkali chemicals
Operating voltage range                             tween receiver tanks
Interelectrode voltage                              and supply tanks is long
Interelectrode current                              or where remote control
                                                    is required.

                         100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz

                         85% to 110% of rated voltage

                         8 VAC                                                24 VAC                       8 VAC
                                                                                                           Approx. 1.2 mA AC max.
                         Approx. 1 mA AC max.                                 Approx.
                                                                              0.4 mA AC max.

Power consumption        Approx. 6.4 VA max.        0 to 1.8 k (for 2 km)     Approx. 15 k to              0 to approx. 1.8 k
Interelectrode operate   0 to approx. 4 k           0 to 0.7 k (for 4 km)     approx. 70 k                 Approx. 5 k to  
resistance                                                                    (see note 5)

Interelectrode release   Approx. 15 k to            4 k to   (for 2 km)       Approx. 300 k to  
resistance                                          2.5 k to   (for 4 km)
Response time
                         Operate: 80 ms max.
Cable length             Release: 160 ms max.
(see note 3)
Control output           1 km max.                  2 km max.                 50 m max.                    1 km max.
                                                    4 km max.
Ambient temperature
Ambient humidity         2 A, 200 VAC (Inductive load: cos = 0.4)
Insulation resistance    5 A, 200 VAC (Resistive load)
(see note 4)
Dielectric strength      Operating: --10C to 55C
(see note 4)
Life expectancy          Operating: 45% to 85% RH

                         100 M min. (at 500 VDC)

                         2000 VAC, 50/60 Hz for 1 min.

                         Electrical: 500,000 operations min.
                         Mechanical:5,000,000 operations min.

Note:  1. The relay in the 61F-G1H/-G2H/-IPH de-energizes when there is water present across the Electrodes, whereas the relay in the
           61F-GP-N8HY energizes when there is water present across the Electrodes.

       2. Models are available for 2 km and 4 km.
       3. The length when using completely-insulated, 600-V, 3-conductor (0.75 mm2) cabtire cables. Usable cable lengths will become

           shorter as the cable diameter or number of conductors becomes larger.

       4. The insulation resistance and dielectric strength indicate values between power terminals and Electrode terminals, between power
           terminals and contact terminals, and between Electrode terminals and contact terminals.

       5. Possible to use with 15 k or less, however, this may cause reset failure.
61F-GjP                                                                                                                                                            61F-GjP

Internal Circuit Diagrams                                           61F-G1PH                                                      61F-G2P/-G2PL/-G2PD
61F-G1P/-G1PL/-G1PD

   7          14      6  5         12                  4      3                7      14        6     5         12      4      3  U2 7          14        6  5     12            4   3

              U2                                          U1                                                               U1
                       24 V Control circuit U1
                                                                                  U2                                                                                         U1

                                                                                          24 V Control circuit U1                                   24 V Control circuit U1

Power             24 V Control circuit U2                              Power                                                         Power
supply
                                                                       supply             24 V Control circuit U2                    supply         24 V Control circuit U2

                  8V                                                                      24 V                                                      8V

                               U2                  U1                                                       U2      U1

8       9     15 10      1         11                  2            8          9      15 10              1      11      2         8          9      15    10 U2 1            11  2

61F-G2PH                                                            61F-IP/-IPL/-IPD                                              61F-IPH

U2 7          14      6  5         12                  4      3        7          14      6        5        12      4      3         7          14        6  5     12            4   3

                                               U1                                 U2      U2       U1                                           U2      U2   U1                  U1
                  24 V Control circuit U1
                                                                                                                    U1
                  24 V Control circuit U2
   Power                                                                              24 V Control circuit U1                                       24 V Control circuit U1
   supply         24 V
                                                                    Power                                                            Power

                                                                    supply            24 V Control circuit U2                        supply         24 V Control circuit U2

                                                                                      8V                                                            24 V

8          9  15      10 U2 1      11                     2      8          9         15 10        1        11      2             8         9       15 10       1  11            2
61F-GjP                                                                                                                                  61F-GjP

Connections
61F-G1P

Application 1: Automatic Water Supply Control with Pump Idling Prevention

Water tank             Water          Water supply                                  The pump stops when the water level reaches E1 and the pump
                       supply         source
                                                                                        starts when the water level in the tank drops below E2.
                          P
                                                                                     When the level of water supply source drops below E2', the

  E1'                  Pump           E1                                                pump stops. Pumping idling is prevented and the alarm sounds.
     E2'               OFF
                                          E2                                        Insert a pushbutton switch (NO contact) between 11 and 15 as
Short-                 Pump                   E3
                       ON                                                               shown by the dotted line below. When starting the pump and
age          E3'                                                                        after recovering from a power failure, if the water supply source
                                                                                        level has not yet reached E1', press the pushbutton switch to
BL                                                                                      start the pump by momentarily short-circuiting E1' and E3. When

                                                                                    the pump stops during normal operation subsequent to an alarm

                                                                                    issued for a low water level, do not press the pushbutton switch.

                                           61F-G1P               Alarm
                                                                   B
                  200-VAC power supply

                       RST

                                                    7 14 U26                   5 12 4                  3
                                                                                                   U1

                                                    Transformer  24 V Control U1

             MCCB                                   0V

                                                                       circuit

                                                                 24 V  Control  U2
                                                                       circuit

                                                    200 V                       U2 U1

                                                                 8V

                                                  8 9 15 10 1 11 2

                                   A                                                                                  Pushbutton switch

                                *                                                                                     PS-3S

                       Electromagnetic
                       switch

                                                                                Water tank                        E1

                  THR                 PS-3S                      Water supply                                E2
                                                                 source                                E3

                            MP                              E1'
                                                  E3 E2'

Note: Be sure to ground terminal 15.
61F-GjP                                                                                                                     61F-GjP

61F-G1P

Application 2: Automatic Water Supply Control with Abnormal Water Shortage Alarm

         Water supply          Water tank                                                The pump stops when the water level reaches E1 and starts
                                            Water drainage
                            P                                                               when the water level drops below E2.

         Pump OFF E1                                                                     If the water level drops below E4 for any reason, the pump stops

                                                                                            and the alarm sounds.

         Pump ON                                                                         Insert a pushbutton switch (NO contact) between 11 and 15.
                                E2

         BL                    E4                                                       When starting the pump and after recovering from a power

         Shortage                   E3                                                      failure, if the water level has not yet reached E4, press the
                                                                                            pushbutton switch to start the pump by short-circuiting E3 and

                                                                                            E4.

                                                                                        If the pump stops upon release of the pushbutton switch, keep

                                                                                            pressing the pushbutton switch.

         200-VAC power supply           61F-G1P                                        B Alarm
                        RST
                                                            7 14 U26              5 12              4      3
           MCCB
                                                                                                           U1

                                                            Transformer   24 V Control U1

                                                            0V

                                                                              circuit

                                                                          24 V Control  U2
                                                                               circuit

                                                            200 V                       U2 U1

                                                                          8V

                                                            8 9 15 10 1 11 2
                                                                                                         Pushbutton switch

                                               A                                                    PS-4S

                                                                  *

                                    Electromagnetic switch

                                                            Water tank                          E1

         THR                                                Water supply      E3            E2
                                                            source                      E4

                                    MP

Note: Be sure to ground terminal 15.
61F-GjP                                                                                                        61F-GjP

61F-G2P
Automatic Drainage Control with Abnormal Water Increase Alarm

Application 1: Drainage

BL                              Water drainage                                                   Connect terminal 8 to power supply terminal 9.
                                            Pump ON                                              The pump starts when the water level reaches E1 and stops
Upper    E4
limit                                                                                              when the water level drops below E2.

                         E1                                                                      If the water level reaches E4 for any reason, the alarm sounds.

                         E2          Pump OFF
                            E3
                                P

                                                                                             Alarm
                                                                                       B

                                                     61F-G2P

                                                     U2 7 14         6                 5 12 4           3

200-VAC power supply                                                 Transformer                    U1
         RST

                                                              0V     24 V Control U1

                                                                                       circuit

                                                                     24 V Control               U2
                                                                           circuit

                                                              200 V  8V

                                                                                       U2

                             Electromagnetic         8        9 15 10 1                         11 2
                             switch                                                                 Reservoir

                                          A

                                          *

    THR

                                MP                                PS-4S
                                                                         Water supply
                                                                         source

                                                             E1 E4

                                                     E3E2

Note: Be sure to ground terminal 15.
61F-GjP                                                                                                                                                         61F-GjP

61F-G2P                                                        Upper L B                               Connect the terminal 6 to terminal 9 (power supply line).
Application 2: Water Supply                                     limit                                  The pump starts when the water level reaches E2, and stops

                           Water supply                               Pump OFF                             when the water level rises to E1.

                                                       P                                                If the water level reaches E4 for any reason, the alarm sounds.

                                                        E4
                                                           E1

                                                               Pump ON

            E2
               E3

                                                                                61F-G2P                                   B

                                                                                                                          Alarm

         200-VAC power supply                                                            7 14                          6         5 12 4                      3
               RST

            MCCB                                                                         U2                                                           U1
                                                                                                   0V                                   U1
                                                                                                       24 V Control circuit

                                                                                         200 V         24 V Control circuit U2
                                                                                                       8V

                                                                                                                          U2

                                                                                8 9 15 10                                        1 11                     2

                    Contactor                                                            Water tank                    PS-4S
            THR

                                                                  Reservoir                                      E1E4
                                                                                                       E3 E2

         M                                                     P

Note: Be sure to ground terminal 15.
61F-IPj                                                                                                                                                                                                             61F-IPj

61F-IP

Liquid Level Indication and Alarm                                                                                                                When the water level drops below E2, the lower-limit indicator

                                                                 B LH Upper                                                                          turns ON and the alarm sounds.
                                                                               limit
                                                                                                  E1                                              When the water level reaches E2, the indicator turns OFF and

                                                                       LM Middle                                                                     the intermediate indicator turns ON.

                       Lower                                                                          E2                                          When the water level rises to E1, the upper-limit indicator turns
         B LL limit                                                                                       E3
                                                                                                                                                     ON and the alarm sounds.

         200-VAC power supply                                                                                    Alarm B                Lower limit
                         RST                                                                                                                         Intermediate
                                                                                                                                                                  Upper limit
                                                                                                                                   PL PL PL

                                                                                                                                                                                   61F-IP

         MCCB                                                                                                 7            14  6        5        12  U1 4                             3

                                                                                                                           U2               U1

                                                                                                                               U2

                                                                                                                           Transformer
                                                                                                                               24 V Control U1
                                                                                                                 0V

                                                                                                                                        circuit

                                                                                                                                        Control
                                                                                                                               24 V circuit U2

                                                                                                                    200 V          8V

                                                                                                                 8         9   15       10       1                             11  2

                                                                                                                            *               Water tank                                           PS-3S
                                                                                                                                                                                                  Upper alarm
                                                                                                              Water supply                                                                   E1
                                                                                                              source                                                           E3 E2                  Intermediate
                                                                                                                                                                                                  Lower alarm

                              MP

Note: Be sure to ground terminal 15.
61F-UHS/HSL                                                                                                                                                        61F-UHS/HSL

Ultra High-sensitivity Models

Use these models for sensing objects such as ice, high-purity distilled water, moisture, or other objects with low electrical conductivity.

Specifications

                Item                                                              High-sensitivity 61F-UHS                   Variable high-sensitivity 61F-HSL

Supply voltage                              100, 200, or 220 VAC; 50/60 Hz                                                   24, 100, 110, 200, or 220 VAC; 50/60 Hz

Operating voltage range                     85% to 110% of rated voltage

Interelectrode voltage                      24 VAC                                                                           13 VDC max.

Interelectrode current                      Approx. 1 mA AC max.                                                             Approx. 1 mA DC max.

Power consumption                           3.2 VA max.

Interelectrode operate resistance 0 to approx. 1 M (see note 1)                                                              0 to approx. 5 M (variable)

Interelectrode release resistance           Approx. 5 M to                                                                   Operate resistance + 2.5 M max.
Cable length                                5 m (see note 2)                                                                 Note 3

Control output                              0.3 A, 220 VAC (Inductive load: cos = 0.4)                                       2 A, 220 VAC (Inductive load: cos = 0.4)
                                            1 A, 220 VAC (Resistive load)                                                    5 A, 220 VAC (Resistive load)

Ambient temperature                         Operating: --10C to 55C

Ambient humidity                            Operating: 45% to 85% RH

Insulation resistance                       100 M max. (at 500 VDC)

Dielectric strength                         2,000 VAC, 50/60 Hz for 1 min

Life expectancy                             Electrical: 50,000 operations min.                                               Electrical: 500,000 operations min.
                                            Mechanical: 5,000,000 operations min.                                            Mechanical: 5,000,000 operations min.

Note: 1. Use 61F-UHS for detecting water leakage with high specific resistance. Connect a sensor cable (page 69) between terminals 1 and
              7.

          2. Two Electrodes can be connected to the 61F-HSL. Use them for an alarm, not for creating a self-holding circuit.

          3. The length when using completely-insulated, 600-V, 3-conductor (0.75 mm2) cabtire cables. Usable cable lengths will become
              shorter as the cable diameter or number of conductors becomes larger. For more details, refer to Short Wiring in Electrode Circuit on
              page 65.

          4. it is recommended that the cable length be kept as short as possible since the Electrode circuit current is at DC micro-current level.
              Moreover, the Electrodes will corrode rapidly if the current is allowed to constantly flow between the Electrodes.
              Be careful with the electrode polarity and grounding when wiring.

Internal Circuit Diagrams

61F-UHS                                                                                            61F-HSL

S1 6     Operation          Rectification/                                                         S1 5                                                                  Relay
           power supply     smoothing                                                                                                                              To each circuit
Power                                      Rectificationcircuit                   To each circuit                                 Rectification
supply                                        smoothing circuit                                                                     smoothing circuit                                    Relay
                                                            Level detection                                  Operation                           Constant voltage
S2 5                                                           circuit            Relay            Power       power supply                         circuit
E3 1                                                               Power circuit                   supply
E1 7
E2 8                                                                                               S2 6
Tb 2
Tc 4                                                                                               7                              Surge--absorbing                 Power circuit
Ta 3                                                                                                                                circuit
                                                                                                   1                                             Level detection
                                                                                                                                                    circuit
         X/a                                                                                       Ground 8
                       X/c
                                                                                                   Tb 2

                                                                                                   Tc 4                      X/c

                                                                                                   Ta 3
61F-UHS/HSL                                                                                                                        61F-UHS/HSL

External Circuit Diagrams (Example)                               61F-HSL
61F-UHS

   45                    Power                                                      4  5            Power
                         source                                                 3          6        source

3      6                                                                        2           7
                                                                                    1  8
2      7

   18

E3 E2 E1                                                                        (--)           (+)

Socket: 8PFA1 (track mounted)/                                    Socket: 8PFA (track mounted)/
             PL08 (back connecting)                                            PL08 (back connecting)

61F-UHS                                                                                2. Water Drainage

Automatic Operation for Water Supply and Drainage
1. Water Supply

       Water supply                                                                                                Water drainage

                          P                                                                                 E1     Pump ON

           Pump OFF E1

          Pump ON                    E2                                                                     E2     Pump OFF
                                        E3                                                                     E3
                                                                                                                      P

Operation: When the water level reaches E1, the pump stops                            Operation: When the water level reaches E1, the pump starts

    and, when the water level reaches E2 or below, the pump starts.                        and, when the water level reaches E2 or below, the pump stops.

Connection: Connect the contactor coil terminal to terminal 2 of                      Connection: Connect the contactor coil terminal to terminal 3 of

    the plug-in model. (Terminal 3 is not used.)                                           the plug-in model. (Terminal 2 is not used.)

                                                                                       61F-UHS

200-VAC power supply                        65                                  4              3
      RST

       MCCB                                                                                     U
                                                                  24 V Control circuit U
                                              0V                  24 V
                                            200 V

                                            78 1                                               2

                      Contactor                                                               Note: The diagram shows the connections for the water supply.
                                                                                                       When draining, change the connection from terminal 2 to
       THR                                                                                             terminal 3.

                                                      Water tank            E1  PS-3S
                                     Reservoir                    E3 E2
                                                                                              Stop
                                                                                              Start

   M                  P

Be sure to ground terminal 1.
61F-APN2                                                                                   61F-APN2

  61F-APN2 Solid-state Alternate Operation Relay

When operating two pumps alternately for controlling the one-point liquid level, use the Relay in combination with 61F Controller.

   61F-APN2 Compact Plug-in Model

Specifications

Ratings

Supply voltage                                      100, 110, 200, 220 VAC; 50/60 Hz
Operating voltage range                             85% to 110% of rated voltage
Power consumption                                   3 VA

Contact Ratings (With G2RK Keep Relay)

                      Item                                       Resistive load (cos = 1)     Inductive load (cos = 0.4, L/R = 7 ms)
Max. load                                           3 A at 250 VAC                         1.5 A at 250 VAC
Carry contact                                       3A
Max. operating current                              3A                                     375 VA
Max. switching capacity                             750 VA

Characteristics                                     Operate: 25 ms max.
Response time                                      Release: 30 ms max.

Minimum pulse width                                Min. ON time: 40 ms min.
                                                    Min. OFF time: 200 ms min.
Insulation resistance                              100 M min. at 500 VDC (between each terminal and power supply)
Dielectric strength
Vibration resistance                               2,000 VAC, 50/60 Hz for 1 min (between each terminal and power supply)
Shock resistance
Life expectancy                                    10 to 55 Hz, 1-mm double amplitude
                                                    10 G (approx. 98 m/s2)
Ambient temperature
Ambient humidity                                   Mechanical: 1,000,000 operations (at operating frequency of 1,800 operations/hour)
                                                    Electrical: 100,000 operations min.

                                                                       (rated load)

                                                    Operating: --10C to 55C

                                                    Operating: 45% to 85% RH

When power is applied to the input terminals 2 and 7, the power will        The above operation repeats each time power is applied to the input
be transmitted through the alternate operation control circuit and          terminals (power application pulse response system). Refer to the
output circuit to turn ON the contacts (NO condition) between 1 and         following internal circuit diagram.
3 and between 6 and 8. This state will be held by a magnetic lock
even when the power to the input terminals is turned OFF.

When power is again applied to the input terminals, the contact (NO
condition) will turn OFF and the contacts (NC condition) between 1
and 4 and between 5 and 8 will turn ON. This state will be held even
when the power to the input terminals is turned OFF.

Internal Circuit Diagram                                                              4
                                                                      X/c1
    2
                                                                                      3
   Power circuit
                 Alternate operation                                                  1
                    control circuit
                                    Output circuit                          5

                                                                      X/c2

7                                                   G2RK (61F-APN2)         6

                                                                            8
61F-APN2                                                                                                    61F-APN2

Connect the output terminal Ta of the 61F-Gj to input terminal 2 of the 61F-APN2.
Connection
Connect the contactor coil terminal A to the switching contact terminals 3 and 4 of the 61F-APN2.
Operation of the two pumps can be displayed using the switching contact terminals 5 and 6 of the 61F-APN2.

          Output contact between
          1 and 3 and 6 and 8

          Output contact between
          1 and 4 and 5 and 8

             Power supply voltage
             between 2 and 7

                                      40 ms min. 200 ms min.

Timing Chart of Water Supply Alternate Operation

                       Ta

          61F

                       Tb

61F-APN2  Power

          Output
          1-3

          Output
          1-4

          Contact 1

                    Contact 2                                           In case of water supply operation, the output contacts of the Alter-
                                                                        nate Operation Relay will be switched after the normally closed con-
When the 61F-APN2 Alternate Operation Relay is used in combina-         tacts of the 61F turn OFF upon reaching the control level, and the
tion with a 61F Controller, the output contacts of the Alternate        output contacts will be already switched when the normally closed
Operation Relay will not be switched (OFF) while the contactor is       contacts of the 61F turn OFF next time.
being excited, and the contactor will not be excited (ON) at the mo-
ment when the output contacts are switched. That is, loads such as      Therefore, only the continuous line current needs to be considered
contactors will not be directly turned ON or OFF by the actions of the  as the load capacity of the 61F-APN2 and the current can be applied
output contacts of the 61F-APN2 Alternate Operation Relay.              up to the rated line current of 3 A.
Instead, they will be turned ON or OFF by the actions of the 61F
Controller.
61F-APN2                                                                                                                                  61F-APN2

Connections
At 200 VAC

Water Supply (When Combined with 61F-G)

                                   The relay operation can be monitored if
                                   indicators are connected as shown by
                                   the dotted line.

             To power source T

             200-VAC power source       L2  L1

             RST  61F-APN2                                                          61F-G

                                        6   5             4  3                                 0V          24 V                        U
                                                                                          100 V            8V      61F-11
                  MCCB                                                                    200 V                    Relay Unit

                                                                                                  U                                 U

                                                Electronic
                                                circuit

                                                                                    Ta                 Tc      Tb      E2      E1

                                        7   8             1  2                                     S0      S1      S2      E3

                                                                                                                                           *

                          Contactor 1                                  Contactor 2                                                        PS-3S
                  THR                                           THR
                                                                                                                   Water tank

                                   Water supply resource                    Water supply resource                                   E2 E1
                                                                                                                               E3

                                    P1                                         P2
                  M1                                         M2

*Be sure to ground terminal E3.
Note: When controlling drainage, change the connections as shown by dotted lines in the following illustration.

                            61F-APN2
                                12

                              Tb Ta
                           61F-G
61F-APN2                                                                                                                                                 61F-APN2

Water Supply (When Combined with 61F-G1)

                      The relay operation can be monitored if
                      indicators are connected as shown by
                      the dotted line.

To power source T

200-VAC power source      L2  L1                               61F-G1

RST           61F-APN2                                                                                      U1

                                                                             0V    24 V         61F-11
                                                                            100 V  24 V
                          6   5   4                  3                                          Relay Unit

              MCCB                                                                              61F-11      U2

                                                                                                Relay Unit

                                  Electronic                                200 V     8V                             U1
                                  circuit                                          U2
                                                                                                U2

                                                                                                                U1

                                                               S0                      Tb1      Ta1             Tc2       Tb2
                                                                    S1
                          7   8   1                  2                             S2       E3          E2  E1       E2'                      E1'

                                                                                                                                                   (E4)

                                                                                                                        B

                                                                                                                                       Alarm

                                                                   *

                     Contactor 1                               Contactor 2
              THR
                                                        THR                                                                                        PS-3S
                                Water supply source
                                                                                                            Water tank

                                                                                                                                                         Water supply source

                                                                                         PS-3S                                     E1
                                                                                                                          E3 E2
                                                                                     E1'
                                                                               E2'
                                                                            E3

          M1          P1

                                                        M2     P2

*Be sure to ground terminal E3.
Note: The 61F-G1 is to be used only for supplying water and cannot be used for alternate operation for controlling drainage.
61F-APN2                                                                                                                               61F-APN2

Water Drainage (When Combined with 61F-G2)

                           The relay operation can be monitored if
                           indicators are connected as shown by
                           the dotted line.

To power source T

200-VAC power source         L2  L1                                 61F-G2
                                                                            0V
          RST      61F-APN2
                                                                         100 V
                                                                                          24 V         61F-11        U1
                                                                         200 V            24 V
                             6   5   4                    3                               8V           Relay Unit
                                                                                          U2
                   MCCB                                                                                61F-11        U2

                                                                                                       Relay Unit

                                     Electronic                                                        U2
                                     circuit                                                                              U1

                                                                    S0               Ta1      TC1      Tb1      Ta2           TC2

                             7   8   1                    2                      S1       S2       E3       E2       E1            E4

                                                                                                                               B

                                                                                                                              Alarm

                          Contactor 1                                         *
                   THR
                                                                    Contactor 2
                                     Water supply source
                                                             THR

                                                                                                  PS-4S
                                                                                                         Water supply source

                                                                                          E1 E4
                                                                                     E3E2

               M1        P1

                                                             M2     P2

*Be sure to ground terminal E3.
Note: When supplying water, change the two connections as shown by dotted lines in the following illustration.

                             61F-APN2
                                12

                               Tb1 Ta1
                           61F-G2
61F-APN2                                                                                                                                                        61F-APN2

Water Supply (When Combined with 61F-G3)

                          The relay operation can be monitored if  61F-G3
                          indicators are connected as shown by
                          the dotted line.

To power source T

200-VAC power source                                                                                          61F-11                    U1
                                   L2  L1                                                           24 V      Relay Unit
          RST      61F-APN2

                                                                                         0V         24 V      61F-11                    U2
                                                                                        100 V                 Relay Unit
                             6         5   4            3

                   MCCB                                                                             24 V      61F-11                    U3
                                                                                                              Relay Unit
                                                                                        200 V

                                           Electronic                                               8V
                                           circuit

                                                                                        U2                    U1 U3                 U1      U3              U2

                                                                   Ta                       Tc      Tb        B1                B2          Lc      E1      E3      E5

                             7         8   1            2                               S0      S1        S2                        LH          LL      E2      E4

                                                                                                                B                            Upper  Upper
                                                                                                                                                    limit
                                                                                                                         Alarm      PL PL limit     indi-
                                                                                                                                             indi-  cator
                                                                                               Power source                                  cator

                          Contactor 1                                      Contactor 2                                                                       PS-5S *
                   THR                                             THR
                                                                                                                                                                    Water tank
                                   Water supply source                                                                                          E1 E2 E3

                                                                                                                                                           E4 E5

               M1        P1

                                                           M2      P2

*Be sure to ground terminal E3.
Note: When discharging water, change the two connections as shown by dotted lines in the following illustration.

                               61F-APN2
                                   12

                                 Tb Ta
                              61F-G3
61F-APN2                                                                                                                                                                   61F-APN2

Water Supply (When Combined with 61F-G4)

                                                                    61F-G4

                                                                                   0V              24 V      61F-11               U5
                                                                                 100 V                       Relay Unit
                                                                                 200 V
                         The relay operation can be monitored                  U2                  24 V      61F-11               U1
                         if indicators are connected as shown            MK3P                                Relay Unit
                         by the dotted line.                             relay X
                                                                                 100 V                       61F-11               U2
To power source T                                                                                            Relay Unit
                                                                                 200 V
200-VAC power supply L2  L1                                                                        24 V

R S T 61F-APN2                                                                                     24 V      61F-11               U3
                                                                                                             Relay Unit

                6        5   4          3                                                                    61F-11               U4
                                                                                                             Relay Unit
    MCCB                                                                                           24 V

                                                                                                   8V

                             Electronic                                          X            U4        U3 X U1 U5 X                   U4            U3                U2 U5
                             circuit

                                                                    U1

                                                                    LL1          LL2          LH1      LH2         BL1       BL2       BH1      BH2            E4      E3      E2      E1

                7        8   1          2                                S0           S1           S2        TC         TC2       B         TA           E8        E7      E6      E5

                                                                    LL1          LL2          LH1       LH2        BL1       BL2       BH1      BH2

                                                                    Shortage        Lower     Full in    Upper     Shortage Lower          Full in Upper
                                                                    in elevated     limit of  elevated   limit of                                    limit of
                                                                    tank            supply    tank       supply    in        limit of      elevated  supply
                                                                                    source               source                            tank      source
                                                                                                                   elevated supply

                                                                                                                   tank      source

            Contactor 1                                             Contactor 2
    THR
                                                               THR       *                                                                                                            PS-5S
                   Water supply source                                                                                                                                                    Water tank
                                                                                                PS-4S
                                                                                   E3 E2 E1                                                                        E8 E7 E6E5 E4
                                                                                 E8

M1        P1

                                           M2                       P2

*Be sure to ground terminal E3.
Note: The 61F-G4 is to be used only for supplying water and cannot be used alternately for controlling drainage.
61F-APN2                                                                                                                                                   61F-APN2

At 220 VAC
Water Supply (When Combined with 61F-G1P)

     Power            For example, operation indication is                                                                         Alarm
     source           possible by the connection as                                                                            B
     220 VAC          shown by the dotted line.

     RST                  L2     L1                                                                                                                 61F-G1P

              61F-APN2

                                                                                                                    7      14  6          5      12                             4  3

                          6      5   4                    3

              Knife                                                                                                                                                         U1
              switch                                                                                                       U2

                                     Electronic                                                                     0V     24 V Control circuit U1
                                     circuit

                                                                                                                           24 V Control circuit U2

                                                                                                                    220 V  8V

                                                                                                                                             U2      U1

                          7      8   1                    2                                                      8  9      15  10         1      11                             2

                        A                                                A                                                                                                      Pushbutton switch

              Electromagnetic switch 1                       Electromagnetic *                                                                   PS-3S
                                                     THR
THR                                                          switch 2                                                                               Water
                                   Water supply source                                                                                              tank
                                                                                                          PS-3S                              E1
                                                                                                                                        E2
                                                                                                      E1                           E3
                                                                                                  E2
                                                                                             E3

     M1               P1

                                                             M2  P2

*Be sure to ground terminal 15.
61F-APN2                                                                                                                                       61F-APN2

Water Supply (When Combined with 61F-GP-N)

                      For example, operation indication is               61F-GP-N
                      possible by the connection as
                      shown by the dotted line.

     Power                      L2      L1                                                       8     7                 6        5
     source                                                                                        0V
     220-VAC  61F-APN

     RST

                                6       5        4  3                                                                            4
                                                                                                       U

              Knife                                                                                        24 V Control circuit U
              switch

                                                 Electronic                                                       8V
                                                 circuit                                         220 V

                                                                                                                      U

                                                                                                 9                                3

                                                                                                 10    11                1        2

                                7       8        1  2

                      A                                               A
                                                             Electromagnetic switch 2
                                                                                                                      *
                                                                            Water supply source
              Electromagnetic switch 1

THR                                         THR                                                                                                PS-3S

                                                                                                                      Water tank

                         Water supply source                                                                                         E3 E2 E1

          M1             P1                                          P2
                                                    M2

*Be sure to ground terminal 4.
61F-APN2                                                                                                                                 61F-APN2

Water Drainage (When Combined with 61F-G2P)                                                                        Alarm
                                                                                                             B
              For example, operation indication is
              possible by the connection as shown                                                                                        61F-G2P
              by the dotted line.

     Power    61F-ANP2 L2    L1                                            7                   14        6       5        12          4  3
     source
     220-VAC

     RST

                          6  5   4              3                          U2                                                     U1
                                                                               0V
              Knife                                                                                24 V                      U1
              switch                                                                                     Control circuit

                                 Electronic                                                        24 V Control circuit U2
                                 circuit

                                                                                           8V
                                                                           220 V

                                                                                                             U2

                          7  8   1              2                       8  9                   15        10      1        11          2

              A                                         A      *
              Electromagnetic switch 1
                                                        Electromag-
                                           THR          netic switch 2

THR                     Water supply source

                                                                                        PS-4S

                                                                             E1 E4
                                                                        E3E2

          M1          P1

                                                    M2     P2

*Be sure to ground terminal 15.
61F-03B/04B                                                                        61F-03B/04B

61F-03B/04B Surge Suppressor Unit

A high-capacity protective device is available which protects 61F-series Floatless Level Controllers against faults arising from electrical surges
(such as indirect strokes of lightning) when the Controllers are employed in elevated water tanks or in high-altitude locations.

Specifications

Discharge start voltage    90 V 20 VDC
Impulse withstand voltage  200,000 V (1 x 40 s)
Impulse withstand current  6,000 A (1 x 40 s)

Internal Connections       61F-04B

       61F-03B

Precautions

1. Mount the Surge Suppressor Unit as close to the Controller
        as possible. Adequate results may not be obtained if mounted
        close to the Electrode Holder.

2. When grounding the Surge Suppressor Unit in the vicinity of
        the Controller, connect the ground side of the Surge
        Suppressor Unit to Electrode E3, E5, or E8 (ground terminal).

                                                                    Long distance

                             61F-03B

                                                     Ground

Connection Sockets

PF113A-E Track-mounted Socket
PL11 Back-connecting Socket
61F                                                                                                                             61F

  Accessories (Order Separately)

Electrode Holders

Applications        For city water and other               When mounting space is        For low specific liquids.  When secure installation
                    General-use Electrodes.                limited. Special 3-pole       Used for sewage, sea       is required.
                    Easy-to-replace separate               holder of small size and      water, etc., having a low  For sewage, city water
                    versions facilitate                    light weight. Ideal for soft  specific resistance. In    and other general use. 3-,
                    maintenance of                         drink vendors, etc., where    sewage use, Electrode      4-, and 5-pole models are
                    Electrodes.                            only limited space is         Holders must be installed  available. In outdoor or
                                                           available.                    10 to 20 cm apart from     dusty locations, or
                                                                                         one another. For acids,    locations subject to water
                                                                                         alkalis and sea water,     splashes, adherence of
                                                                                         Electrode Holders may be   water, dust, dirt, or other
                                                                                         as much as 1 meter apart   foreign matter to the
                                                                                         to operate properly.       Electrode insulator may
                                                                                                                    cause Controller
                                                                                         Flange                     malfunctioning due to
                                                                                                                    leakage. Be sure to use
                                                                                         Ceramics                   the Protective Cover.
                                                                                         150C max. (without water
Mounting style      Flange                                 Screw                         drips or vapor on the      150C max.
Insulator material  Phenol resin                           PS-31                         surface of the Electrode
Max. temperature    70C max.                                                            Holder)

Appearance          PS-3S(R)                                                             BF-1                       BF-3(R)     Heat re-
                    PS-4S(R)                                                                                        BF-4(R)     sisting
                    PS-5S(R)                                                                                        BF-5(R)     temp.

                                                                                                                                Heat re-
                                                                                                                                sisting
                                                                                                                                temp.

                                                           (see note 2)

No. of        1 ---                                        ---                           BF-1                       ---
Electrodes                                                                               ---                        BF-3(-3R) (see note 2)
              3 PS-3S(-3SR) (see note 1) PS-31                                           ---                        BF-4(-4R) (see note 2)
                                                                                         ---                        BF-5(-5R) (see note 2)
              4 PS-4S(-4SR) (see note 1) ---

              5 PS-5S(-5SR) (see note 1) ---

Note: 1. Those with the suffix R in their model name are for 2-wire circuits.
          2. The Electrode material for PS-31 is SUS304. (Length: 300 mm)

Applications        When resistance to high                When corrosion                When Electrode positions   When Electrode positions
                    pressure is required. Ideal            resistance is required.       are distant from water     are distant from water
                    for use in tanks where                 Since Teflon is used as       surface.                   surface.
                    temperature or pressure                the main part, the            For deep well, especially  For deep well and
                    inside the tank is high,               Electrode is free from rust   sewage. Several            underwater pump. 2 sets
                    e.g. 250C, 1.96 MPa                   and corrosion. Ideal for      Electrodes are used in     of special Electrodes
                    {20 kg/cm2}                            liquid level control in food  combination.               attached to cabtire cables
                                                           processing, level control     Cable length: 100 m max.   for upper- and lower-limit
                                                           of strong alkaline liquids,   Single-core cord of        control are to be
                                                           etc.                          0.75 mm2 (30/0.18)         suspended in water.
                                                           Withstand pressure:           provided.                  Cable length: 100 m max.
                                                           981 kPa {10 kg/cm2}                                      Two-core cord of
                                                                                                                    0.75 mm2 (30/0.18)
                                                                                                                    provided.

Mounting style      Screw                                                                ---
Insulator material
Max. temperature    Teflon                                                               ---

Appearance          250C max. (without water              150C max.                    With vinyl cord: --10C to 60C
                    drips or vapor on the                  SUS                           With chloroprene cord: --30C to 70C (without frost
                    surface of the Electrode                                             formation)
                    Holder)

                     Maximum tightening          Heat re-                Hastelloy
                     torque at the terminal:     sisting                 titanium
                     14 kgDcm (137.2 N)          temp.:
                                                 150 _C

                    Material at tightening sec-  Heat re-
                    tion: iron (standard),       sisting
                    SUS304, SUS316               temp.:
                                                 250 _C

No. of        1 BS-1                                       BS-1T                         PH-1                       ---
Electrodes    2 ---                                        ---                           ---                        PH-2
61F                                                                                                                      61F

Note:  1. The BS-1 and BS-1T are pressure-proof models. The rest of models are not pressure-proof.

       2. The BS-1 that uses SUS304 for clamping sections and screws of PT1/2 specifications is called BS-1S1.
       3. The BS-1 that uses SUS304 for clamping sections is called BS-1S and one that uses SUS316 is called BS-1S2.
       4. When using the BS-1T in liquids with low specific resistance, provide a large clearance between Electrodes. This clearance must be

           varied depending on the specific resistance, for example, approximately 1 m for acid or alkali liquids.

Electrodes, Connecting Nuts, and Lock Nuts

Applicable       Material    Electrode          Models for individual Electrode assembly components
  liquids                    assembly
                                        Electrode (1 m long)      Connecting nut               Lock nut             Spring
                                                                                                                    washer

                             Model      Model   Indication        Model      Inscrip-  Model      Inscrip-               Model
                                                   mark                        tion                 tion

Purified city    Equivalent  F03-60     F03-01  1 line            F03-02  ---          F03-03  ---                  F03-04
water,           to SUS      SUS201     SUS201                                                                      SUS201
industrial       304                                              SUS201               SUS201
water,           (AISI-304)
sewage

Purified city    SUS316      F03-60     F03-01  2 lines           F03-02  6            F03-03  316                  F03-04
water,           (AISI-316)  SUS316     SUS316                                                                      SUS316
industrial                                                        SUS316               SUS316
water,
sewage,
dilute alkaline
solution

Sodium           Hastelloy F03-60       F03-01  3 lines           F03-02  B            F03-03  B                    ---

hydroxide, B                 HASB       HASB                      HASB                 HASB

acetic acid,

dilute sulfuric

acid, dilute

hydrochloric

acid

Sea water, Hastelloy F03-60             F03-01  4 lines           F03-02  C            F03-03  C                    ---

ammonia          C           HASC       HASC                      HASC                 HASC

water, nitric

acid

Acetic acid, Titanium F03-60            F03-01  5 lines           F03-02  T            F03-03  T                    ---

dilute sulfuric              CHITAN CHITAN                        CHITAN               CHITAN

acid, sea

water

Note:  1. An Electrode assembly consists of the following parts:
                One Electrode (1 m)
                One connecting nut
                Two lock nuts
                Two spring washers

       2. The material indication mark(s) are inscribed near the screw threads, and represent the material composition of the Electrode.

       3. Standard Electrodes are made of stainless steel and usable in purified water, sea water, sewage, acid (except acetic acid, sulfuric
           acid, etc.) and alkaline liquids. They may corrode depending upon the temperature and working conditions.

       4. Corrosion-resisting Electrodes made of SUS316 (AISI-316) and acid-resisting Electrodes made of titanium or hastelloy are also
           available.

                    Electrode

                                    Material
                                    indication
                                    mark

       5. When long Electrodes are required, connect them with connecting nuts and lock nuts (2 pieces) every 1 m.
61F                                                                                                                   61F

Electrode Separators                           Model              When the required length of Electrode is more than 1 m, use a Sepa-
                                F03-14 1P                         rator at each joint of two Electrodes so as to prevent the Electrodes
         No. of Electrodes      F03-14 3P                         from contacting one another.
1                              F03-14 5P                         Use a one-pole type for BF Electrodes. The five-pole type can be
3                                                                used for PS-5S and PS-4S Electrodes.
5                                                                Material: Ceramic

             Electrode Holder               Separator
             Separator
                                            Connecting nut
                                            Spring washer
                                            Lock nut
                                            Electrode

Electrode Band                                                    The Electrode Band consists of polyvinyl-chloride-covered

         F03-05 3P, 4P, and 5P                                        (PVC) stainless-steel wires SUS304 (AISI-304) which are free
                                                                      from mutual contact. As the Electrode Band can be cut,
Sheath: Vinyl chloride                                                mounted, and removed with ease, it is most suitable for deep
Core: 0.3 dia. x 21, straight wire, SUS304                            wells.
Length: 50 m max. (When ordering, specify the length by meters.)
                                                                   Applicable Electrode Holders:
The Electrodes come in three types: 3P, 4P, and 5P. Each of them
require the following accessories that are separately sold.           PS-3S, PS-4S, PS-5S, BF-3, BF-4, BF-5

Accessories Weight                       Electrode                Ambient operating temperature: --10C to 60C (with no icing)
                       (per 1)                                     The Electrode Band cannot be used in flowing water, liquids over
                                    3P      4P              5P
                                3                                     60C, or liquids which corrode PVC or stainless steel.
Connecting   Approx.                     4            5           Application Example
nut          20 g               3 to 4
Weight                                   4 to 6       5 to 8                                     Electrode Band connecting nut
             Approx.            3
End cap      50 g                        4            5                                                                  Weight
                                2                                                                    Electrode Band
Insulation   Approx.                     3            4                                  End cap
Cap          1g                 1
Adhesive                                 1            1
             Approx.            Approx.
Electrode    10 g               110 g    Approx. Approx.
Band weight
(1m)         Approx.
             5g

             ---

                                         140 g        180 g
61F                                                                                                                                 61F

Other Accessories                               F03-12 Spring Clamp                           F03-13 Mounting Frame for installing in
                                                                                                                    concrete
             F03-11 Protective Cover
                                                                                              Useful frame for burying in concrete. Cut
Use this Cover for PS-series Electrode          Used to clamp an Electrode Holder with        as required based on the concrete depth.
Holders with Mounting Frames (upper one         ease, as shown in the illustrations, when
in the following illustration), This Cover can  the Electrode Holder is applied to a tank                               115 dia.
also be used when installing the BF-series      without a coupling.                                                          96
Electrode Holders outdoors. Since this          Squeeze the mounting frame into the
Cover is not water-proof, water or dust may     Holder as shown below.                                 80
enter through the wire hole (lower one                                                          100 60
below).                                         Applicable Electrode Holders:
                                                PS-3S(R), PS-4S(R), PS-5S                                                                          70
Applicable Electrode Holders:
BF-3, BF-4, BF-5, PS-3S(R), PS-4S(R),                    10                                                             72 dia.
PS-5S(R)                                                                                                                82 dia.

                           Weight:              Four, M5 x 25  96
                           approx. 65g          mounting
     60                    Operating            screws         112 dia.

                           temp.: --10C
                           to 70C

                 120 dia.

                                                                                              Mounting Frame em-     Electrode
                                                                                              bedded into concrete
Two, M5 x 25                                                   Electrode
mounting screws                                                                                  Commonly used with
                                                                                                 Mounting Frame

           Electrode

Mounting

PS-3S Electrode Holders

1. Mounting Electrode Holder                    2. Attaching Electrode(s) to Electrode        3. Inserting Electrode section into
                                                section                                       Electrode Holder
Screw the Electrode Holder into the
                                                 Insert each Electrode into the connecting    Fit the Electrode section into the
    coupling secured at the installation
    location.                                       nut, secure the Electrode with the clamp      Electrode Holder and secure it with the
                                                    screws, and then tighten the lock nut.        two screws.
Twin                       Electrode
clockwise                  Holder                Connect the leads, inserted through the      Check the Electrode section for proper

                                                    hole of the rubber bushing, into the          wiring, fit the rubber bushing in position,
                                                    respective terminals.                         and then cover the Electrode Holder with
                                                                                                  the drip-proof cover.
                                                         Electrode section
                                                         housing                                          Drip-proof
                                                                                                          cover

                                                                          Rubber                Electrode
                                                                          bushing               section
                                                                                                housing
                                                                          Electrode
                                                                                              Electrode
                                                Lock nut                                      Holder

     Coupling

Note: 1. OMRON does not sell couplings.
          2. Screw in the Electrode until it reaches the bottom of the nut. Insufficient insertion will cause a faulty connection.
61F                                                                                                                                                        61F

  Installing PS-jS Electrode Holder on Tank

1. For tanks with thin walls combined with the F03-12 Spring Clamps
   1. Using the F03-12 as a nut

                                                         PS-jS

                                 Tank

                                                         F03-12

2. Using the F03-12 as a flange                                                                                                                 Electrode
                                                                                                                                            Electrode
                                               PS-jS

                                       F03-12

                                 Tank

                                                                                                                Screw (attached to F03-12)

2. For tanks with thick metal walls
   1. Fabricate screw threads of the same size as for the PS-jS in
        the tank

                                                                                                  PS-jS

                                       Tank                                                                                                 Electrode

3. For concrete tanks                                      PS-jS
                                             F03-12
                                       F03-13

                                               Concrete                                                                                     Electrode
61F                                                                                                                                     61F

  Electrode Holder and Electrodes                                                      Connecting One Electrode to Another

How to Mount Electrodes                                                                When a long Electrode is required, use two or more Electrodes by
                                                                                       jointing them with a connecting nut and two lock nuts at intervals of
Connecting Electrodes to Electrode Holders                                             1 m.

                                                   Electrode Holder

                                        Clamp screw                                                            Electrode

                    Connecting nut  3. Tighten the Electrode with the                                          Lock nut                 Fit each Electrode into the
                                          two clamp screws. (see note)                                                           2.     connecting nut so that the
1. Spin a locknut and a spring                                                                                                          ends of the two respective
     washer onto the Electrode.      Spring washer (see note)                                                  Spring washer            Electrodes contact with one
                                                                                                                                        another at the center of the
                                    4. Secure the connecting nut by                                            Connecting nut           connecting nut.
                                         tightening the lock nut and
                                         spring washer.                                                                                 3. Tighten the Electrodes with
                                                                                                                                             the two clamp screws.
                                                                                                       Spring
Lock nut             2. Fully fit the Electrode into the                                               washer                           4. Secure the connecting nut
  Electrode               connecting nut attached to                                                                                         with the two lock nuts and
                          the Electrode Holder.                                                                                              two spring washers. at both
                                                                                                                                             ends of the connecting nut.

             Note: Clamp screw and spring washer are not                                               1. Spin a locknut and a spring
                       provided for the BS-1T Electrode Holder                                              washer onto each Electrode
                       (titanium, hastelloy B, or hastelloy C).                                             end.

PH-1/PH-2 Electrodes

PH-1                                               PH-2
(See Notes 1 and 2)
                                                                              E2
                                                                              (white)

                                                                     E3                E1
                                                                     (black)           (white)

                                    Control range

             200 mm max.                                                               Control range
                                                                                                 5 mm

Note: 1. When the distance between E1 and E3 exceeds 1 m for supplying purified city water, for example, locate a second E3 within 200 mm
              of E1.

          2. Even when the distance is less than 1 m, the product may not operate due to the water quality.
61F                                                                                                                                                     61F

Electrode Bands                                                                                  Mounting Weight(1)

Connecting Electrode Holder and Electrode Band                                                    To mount an Electrode Band Weight on an
                                                                                                  Electrode Band, firmly tighten the two
Connect the connecting nut to the Electrode section as shown in the illustration below            screws A or B. The needle screws will
and secure the connecting nut with the clamp screw. Insert the Electrode Band into the            come into contact with the electrode wire
lower hold of the connecting nut, and tighten the two clamp screws so that the                    (conductor) allowing the Electrode Band
conductor in the Electrode Band will come into contact with the connecting nut. Then              Weight to become an electrode plate. (Be
mount the Electrode Holder to the Electrode section and secure them with two                      sure to use screw holes A or B.). The
mounting screws, which are provided with the model.                                               Electrode has guides for connecting
                                                                                                  screws as shown by the arrows below so
         Drip-proof                         Connecting nut           Securing                     that connecting screws can be properly
         cover                              (SUS304)                 screws
                                                                                                  inserted into the conductor. A
     Electrode                                            Electrode
     section                                              band                                             Electrode Band
     housing

     Connecting
     nut

       Electrode
       Band
       Electrode
       Holder

                                                                                                                                Guides

                                                                                                  B                             F03-07 Weight (SIS304)

Mounting Weight (2)                         Mounting Insulation Cap                               Mounting End Cap

Install Electrode Band Weights in three     Cover each Electrode Band Weight with an              Cover the Electrode Band end and apply
positions. The Electrode Band Weights       Insulation Cap so as to prevent false                 the Adhesive sold separately to prevent
work as short, medium, and long             detection due to contact between the                  water from entering between the sheath
Electrodes, allowing the Electrode Band to  Electrode and tank. Deform the Insulation             and the the End Cap.
detect high, medium, and low levels of      Cap to an ellipsoid before installing it on
liquid.                                     the Electrode Band Weight.

                                                                                                                                F03-10
                                                                                                                                Adhesive

                                                                     F03-09 Insulation Cap (PVC)  F03-09 End Cap (rubber)

In purified city water, if the distance between the long Electrode (E3) and short Electrode (E1) is more than 50 cm, install another
Electrode Band Weight as E3 in the vicinity of E1 at intervals of 15 to 20 cm, referring to Mounting Weight (2) above. An Insulation Cap
is not needed for the long Electrode.

                     Secure the Weight                               Connect the Electrode
                     with needle screws.                             wire to the connecting nut.

                     Insulation Cap                                  E1 (short)

                                                                     E3 (long)

                                            Control range                              Add another E3 (long Electrode)
                                                                                       Weight if this distance is more than 50
                                            Insulation Cap           E2 (medium) cm.
                                                     End cap
                                                                       E3 (long)
61F                                                                                                                                            61F

  Mounting the Protective Cover on the                                                             Mounting the Protective Cover on the
PS-series Electrode Holder                                                                       BF-series Electrode Holder (BF-3/4/5)

Attach the F03-12 Mounting Frame to the bottom of the PS-series                                  Remove the two mounting screws (M5 x 25) of the BF-series Elec-
Electrode Holder as shown below. Next, place the F03-11 Protec-                                  trode Holder and attach the two cap screws (M5 x 25) supplied with
tive Cover on top of the Electrode Holder and press on it until a click-                         the F03-11 Protective Cover.
ing sound is heard. For mounting purposes, the cap screw attached
to the Protective Cover is not required.                                                         Next, put the Protective Cover over the top of the BF-series Elec-
                                                                                                 trode Holder, and then tighten the supplied two screws (M3 x 20 with
                                                                               Protective Cover  washers). Refer to the following illustration.

                                                                                                 Tighten here       M3 x 20
                                                                                                                    Washer
Secure with the    PS-series Electrode
claw of the cover  Holder

                                                                                                                             Protective Cover

                   Cross-section of the tank

                                                                                                 Cap screw M5 x 25

                                                                                                                             BF-series Electrode Holder

Dimensions

Note: All units are in millimeters unless otherwise indicated.

  Standard Models

61F-G

                                                                                                 M3 screw                    Mounting Holes

                                                                                                                                             Four, 6-dia mounting holes

                   Four, 6-dia holes

61F-G1                                                                                           M3 screw                    Mounting Holes
61F-G2
61F-I                                                                                                                             Four, 6-dia mounting holes

                   Four, 6-dia holes
61F                                                                  M3 screw                   61F

61F-G3                                                                         Mounting Holes

                                                                                 Four, 6-dia mounting holes

        Four, 6-dia holes

61F-G4

                                                                     M3 screw  Mounting Holes

                                                                                 Four, 6-dia mounting holes

                                                  Four, 6-dia holes            61F-
                                                                               GP-N
Plug-in Models
                                                                               PF113A-E
61F-GP-N

61F-GP-N8

                                                                               61F-

                                                                               GP-N8     91

                                                                               PF083A-E
61F                                                           61F

61F-G1P                                       61F-G1P
61F-G2P                                       61F-G2P
61F-IP                                        61F-IP

  Ultra High-sensitivity Models                 14PFA

61F-UHS                                                   8PFA1

  61F-HSL                                                  8PFA

  Solid-state Alternate Operation Relay  61F-
                                         APN2
61F-APN2                                 PF083A-E

  Surge Suppressor Unit                         61F-03B
                                                61F-04B
61F-03B
61F-04B                                      PF0113A-E
61F                                                                                                                                                 61F

Electrode Holders                                                                                                                     Mounting Holes

PS-3S/-4S/-5S                                            PF2 parallel thread                                                                                  Used with
PS-3SR/-4SR/-5SR                                       (effective dia.: 58.135)                                                                                coupling
(see note)
                                                                                                   34 dia.
                                       9-dia. rubber
                                      bushing (inner)

                                                                                                                                                         65 dia.     With
                                                                                                                                                         hole     Mounting
                                                                                                                                                                   Bracket

                                                                                    PS-3S (approx. 150 g)     PS-4S (approx. 170 g)   PS-5S (approx. 185 g)
                                                                                    PS-3SR (approx. 155 g)    PS-4SR (approx. 175 g)  PS-5SR (approx. 190 g)

                                                                                                                                                     Mounting Screw Holes

Note: The PS-3SR, PS-4SR, and PS-5SR have built-in resistor of 6.8 k and used for the two-wire 61F models.

PS-31                                                                               PF1/2 Parallel thread

                                                                                                                       11 dia.        Mounting Holes

Weight: approx. 325 g

                                                       Electrode                    Rubber
                                                       SUS304
                                                                                 3  packing

                                                                       M3                                              29.5 dia.
F03-31 Dust-preventive rubber cap (optional)

       Weight: approx. 20 g                            Note:               Standard holder construction includes three integral
                                                                           300-mm-long Electrodes. However, a model having
                                                                           1,000-mm-long Electrodes is available on request.

BF-1                                                                                Terminal bolt  Cast iron  Two M5 x 25                    Mounting Holes
                                                                                                              mounting screws
Weight: approx. 125 g                                                               SUS201 (M6)                                       26-dia. hole

                                                                                    Nut (M6)

                                                                                                              20 dia.

                                                                                                                                      Two, 6-dia. holes
61F                                                                                                                                              61F

BF-3/-3R                                    BF-3
BF-4/-4R                                    Weight: approx. 420 g
BF-5/-5R
                                            BF-3R
                                            Weight: approx. 425 g

                                                                                   Two, 6-dia. holes              Mounting Holes

                                                                       Three, 26-dia.                        64-dia. hole
                                                                       holes

                                            BF-4                                                             Two, 6-dia. holes
                                            Weight: approx. 520 g
                                                                                                                  Mounting Holes
                                            BF-4R
                                            Weight: approx. 525 g

                              Two, M5 x 25
               Cast iron mounting holes

Terminal bolt  Nut               M6
SUS201

                                                                                 Four, 26-dia.

                                                                                 holes    Two, 6-dia. holes

                                                                                                             Two, 6-dia. holes

                                            BF-5                                                                   Mounting Holes
                                            Weight: approx. 710 g
                                            BF-5R                                                  Two, 6-dia. holes
                                            Weight: approx. 715 g                Five, 26-dia.
                                                                                 holes
                                                110 dia.

BS-1                                                              Width across flats: 20
                                            Terminal bolt
Weight: approx. 70 g

                                            SUS304 (M4) P=0.7                             Two, M4                     Mounting Holes

                                                           Nut (iron)                                    24 dia.

                                                                                                                                 M18 P=1.5
                                                                                                                            (fine screw thread)

BS-1T                                       Terminal bolt                                                             Mounting Holes
                                              SUS304
                                              SUS316       M4 nut Width between                 Two, M4
                                              Titanium     SUS304 flats: 20.5

                                            Hastelloy B
                                            Hastelloy C

                                                                                                             24 dia.  M18 P=1.5

                      Hastelloy                                                                                       (fine screw thread)
                      titanium

                                                                                                   This nut is made of Teflon
                                                                                                   A connecting nut made of Hastelloy B, Hastelloy
                                                                                                   C, or titanium is not supplied with two M4 screws
                                                                                                   and thus has no holes for such screws.

Material              SUS304                SUS316                 Titanium                        HAS B              HAS C
Weight                Approx. 55 g          Approx. 55 g           Approx. 45 g                    Approx. 65 g       Approx. 60 g
61F                                                                                                                                      61F

PH-1                                             PH-2
(Approx. 140 g with a 1-m cord)                  (Approx. 235 g with a 1-m cord)

                                                                                            Two, 6-dia. holes PVC resin (black)

                                          Resin

     19 dia.                                                                       5 dia.                                                Two-core
                                                                      26 21.7                                                            cable
                                                 Single-core          dia dia.
                                                 cable                .

          Cable OD: Vinyl 5.0 dia., Chloroprene 6.5 dia.                                    Cable OD: Vinyl, Hypalon 6.8 dia.

     Note: Cable is supplied in lengths of 1, 5, 10, 15, 20, 30, 40,
               50, 60, 70, 80, 90, or 100 meters.

Electrode Separators                             F03-14 3P for three poles                  F03-14 5P for five poles

          F03-14 1P for one pole                                 Three, 7 dia.                                       Five, 7 dia.

                             6.5 dia.

                              28 dia.                                                   20  20
                    Weight: Approx. 15 g
                                                                          41                               46
Electrode Bands                                               Weight: Approx. 30 g              Weight: Approx. 30 g

F03-05 3P, 4P, 5P                                                                           F03-06 Electrode Band Connecting Nut
                                                                                            (SUS304)
                                          Black printing Outer sheath: PVC
                                          (1 mm wide) Core: SUS304, 0.3 dia. x 21 twisted                        5.5 dia.

                                                                                            F03-07 U-shaped Electrode Band Weight
                                                                                            (SUS304)

                                                                                                                               M4

                                                                      5 dia.

                                                                                            Four M4 needle screw

                                                                                            F03-08 End Cap (Neoprene Rubber)

                                                                                            10 dia. 4 dia.                       8 dia.
61F                                                                                                                        61F

  Connecting Sockets                                         Track-mounted Socket                  Back-connecting Socket
                                                 8PFA1
Available Models                                 8PFA                                        PL08
                                                 PF083A-E                                    PL08
          Model No. of Controller Unit           14PFA                                       PL08
                                                                                             PL15
61F-UHS                                         PF113A-E
                                                                                             PL11
61F-HSL                                         PF083A-E
                                                 PF113A-E                                    PL08
61F-APN2                                                                                    PL11

61F-G1P
61F-G2P
61F-IP

61F-GP-N
61F-GPN-V50

61F-GP-N8

61F-03B
61F-04B

Track-mounted Sockets

PF083A-E  Eight, M3.5 x 7                                                          Terminal Arrangement/
          sems screws                                                              Internal Connections
                                                                                   (Top View)
                                                 Two, 4.2-dia.
          52 max.                                holes                                                              Mounting Holes

                                                        25 dia.                                                        Two, M4 or 4.5-dia. holes

                                                                 21 max.

                                        41 max.

8PFA                                                                                         Terminal Arrangement/  Mounting Holes
                                                                                             Internal Connections
          Eight, M3.5 x 7                                                                    (Top View)
           sems screws
                                                                                                                    Two M4 or 4.5 dia. holes
          81 max.
                                                 Two, 4.5 dia.
                                                     holes

                                                                                   118 max.

                             51 max.                                      24 max.

8PFA1     Eight, M3.5 x 7                                                                    Terminal Arrangement/   Mounting Holes
           sems screws                                                                       Internal Connections
                                                                                             (Top View)             Two M4 or 4.5 dia. holes

                                                 Two, 4.5 dia.
                                                     holes

          93 max.                                                                  130 max.

                                        51 max.

                                                                          24 max.
61F                                                                                                                                                            61F

14PFA                                                                                                                   Terminal Arrangement/   Mounting Holes
                                                                                                                        Internal Connections
           Fourteen, M3.5 x 7                                                                                           (Top View)
               sems screws
                                                                                                                                Two 4.5 dia. or M4 mounting holes
          52 max.
                                                                              Two, 4.5 dia.
                                                                                  holes

                                                                                                         118 max.

                                        72 max.                                                 31 max.
             M3.5 x 11.5 sems screws for terminal screws
PF113A-E                                                                                                 Terminal Arrangement/
                     Eleven, M3.5 x 5                                                                    Internal Connections
                     sems screws                                                                         (Top View)

          52 max.                                                                                                                              Mounting Holes

                                                                                                                                                Two, M4 or 4.5-dia. holes

                                                                                       31 max.

Back-connecting Sockets                                                                                  Terminal Arrangement/                 Mounting Holes
PL08
                                                                                                         Internal Connections Two, 3.5-dia. or M3 Controller
                                         50.5 max.                                                       (Top View)
                                                                                                                                Unit mounting holes
                                                                     35 max.
                                                                                                Two, 2-dia. holes       Two, 3.5-dia. or M3 Socket
                                                                                                                               mounting holes
                                                                              30 dia.

                                                                                                                                                31 dia.
                                                                                                                                                  hole

                                                                                       Approx. 20.5

PL11                                                                                                     Terminal Arrangement/                 Mounting Holes
                                                                                                         Internal Connections

                                                                                                         (Top View)     Two, 3.5-dia. or M3 Socket

                                                                                                     Two, 2-dia. holes          mounting holes

          51 max.                                                                                                                               31 dia.
                                                                                                                                                  hole

                   35 max.                                                             Approx. 20.5
61F                                                                                                    61F

PL15                                                     Terminal Arrangement/  Mounting Holes
                                                         Internal Connections
                                                16 max.  (Top View)             Two, 3.5 dia. or M3 Controller
                                         41 max.                                      Unit mounting holes

                                                                           Two, 3.5-dia. or M3 Socket
                                                                                  mounting holes

                                                         Two 2-dia. holes

      66 max.                            22 max.
                                45 max.
61F                                                                         61F

Mounting Brackets

When the 61F-G1P/-G2P/-IP/-UHS/-HSL is mounted with a Track-mounted Socket, the Controller is held secure by Mounting Brackets at-
tached to the Socket.

61F-GP-N                                                      61F-03B/-04B

To mount the 61F-GP-N or 61F-GPN-V50 on the PF113A-E Track-   When mounting the 61F-03B/-04B on the PF113A-E Track-
mounted Socket, use the PFC-N8 Mounting Brackets attached to  mounted Socket, use the PFC-A1 Mounting Bracket.
the Socket as accessories.
                                                              PFC-A1
PCF-N8

                   Approx.
                      80

To mount the 61F-GP-N or 61F-GPN-V50 on the PL11 Back-con-    To mount the 61F-03B/-04B Unit to the PL11 Back-connecting
necting Socket, use the PHC-5 Mounting Brackets.              Socket, use the PLC-1 Mounting Brackets.

PHC-5                                                         PLC-1

                                                              61F-GP-N8/61F-APN2
                                                              To mount the 61F-GP-N8/61F-APN2 on the PF083A-E, use the
                                                              PFC-N8 Mounting Bracket.
                                                              PFC-N8

                                                                                                                                    Approx.
                                                                                                                                        80
61F                                                                                                     61F

  DIN Track Mounting Accessories                                   End Plate

DIN Track                                                          PFP-M

PFP-100N
PFP-50N

                                                                              M4 x 8
                                                                              Round
                                                                              head
                                                                              screw

             (see note 1)                (see note 1)

DIN Track                  (see note 2)                                               M4 spring washer

PFP-100N2                                                          Spacer

                                                                   PFP-S

                                  (see note 2)

    Note: 1. The PFP-100N is 15 mm on both ends, while the PFP50N
                   is 15 mm on one end and 5 mm on the other end.

              2. Indicates total DIN Track length.

1 m: PFP-100N
50 cm: PFP-50N
1 m: PFP-100N2
61F                                                                                                                      61F

Connection with SE Motor Protective Relay

Prevents Burnouts in Motors and Pumps

                                                                            Static relay for protection of motors and pumps against problems
                                                                            due to overload, open phase, reverse phase, etc.

                                                                            Applicable to all 61F-series Controllers except for 61F-I (indicator
                                                                            model).

Connection Example (When Combined with 61F-G)

                             Power source
                              RST

                                                61F-G

                                                       Ta         0V     Transformer
                                                                          24 V 61F-11N
                                                S0                                 Relay Unit                    E1
                                                          Tc
                                                                            8V
                                                S1                100 V                        U                 E2

                                                       Tb         220 V

                                                S2                                                               E3

                                                                                                                 Ground

     Electromagnetic switch                         B

                             Model SET-3        Ta            Tc  Tb W                            E1
                             current converter
                                                                  Model SE motor relay                       E2
                                +                                                              E3
                                                C+ C-- U                 V
                                --                                                              Water tank
61F                                                                                                                            61F

Application Examples                                                       Dispensing of liquids by volume.
                                                                           Indication of liquid buildup due to filter blockages.
Level control in tanks, reservoirs, sewage plants, underground          Pollution/foul water detection for rivers, drains, etc.
                                                                           Alarm control warning of abnormal or dangerously high or low
    wells, mixing plants etc.
                                                                              levels.
Level control for element protection in pipes, channels, and

    irrigation systems.

Flow detection in pipes, channels, and irrigation systems.

Ice bank control in cold drink dispensers, ice makers, water

    chillers, bulk milk tanks, etc.

61F Selection Guidelines

The limit of specific resistivity of a fluid controlled by the          Table 2 Detectable Resistivity Ranges

    general-purpose model at an immersion depth not exceeding                              Model         Resistivity (recommended
    30 mm is 30 -cm, using PS-3S Electrode Holders. Use the                                                           values)
    high-sensitivity models (H type) for liquids with higher resistivity  Long-distance models (4 km)
                                                                          Long-distance models (2 km)    5 k S cm max.
    (see note 1). Refer to the resistivity values listed for water and    Low-sensitivity models         10 k S cm max.
                                                                          2-wire models                  10 k S cm max.
    other liquids in Table 1 and Table 3 when selecting the unit          General-purpose models         10 k S cm max.
                                                                          High-temperature models        10 to 30 k S cm
    specification. The resistivity range detectable by the 61F is         High-sensitivity models        10 to 30 k S cm
                                                                          (compact plug-in models)       30 to 200 k S cm
    shown in Table 2. Refer to the information on the units and the       High-sensitivity models
                                                                          (standard models)              30 to 300 k S cm
    fluid to be controlled when selecting the appropriate model.          Ultra High-sensitivity models
                                                                                                         100 to 10 k S cm
Note:  1. The high-sensitivity models may suffer from resetting
           problems when used with certain types of water. In
           some cases it cannot substitute for the general-purpose
           models or low-sensitivity models. Be sure to select the
           model appropriate for the application.

       2. The circuit configuration of the 61F-jH high-sensitivity        Note: The specific resistivity ranges of fluids to be controlled are
           model is designed so that the relay de-energizes when                    given for the PS-3S at an immersion depth not exceeding
           there is water present across the Electrodes. When                       30 mm.
           power supply voltage is applied, the internal relay turns
           to the NO contact and, when the electrode between E1           Table 1A Conductance Values of Water
           and E3 becomes conductive, the relay is reset to the NC
           contact. This contact operation is reverse for models                 Water type                 Conductance
           other than the high-sensitivity models. Although the in-       City water         100 to 200 S/cm
           ternal relay operates (and operation indicator turns ON)       Well water         200 to 500 S/cm
           simply when the power supply voltage is applied, this          River water        67 to 200 S/cm
           operation is not abnormal. (The relay in the 61F-jNH           Rain water         40 to 67 S/cm
           energizes when there is water present across the Elec-         Sea water          33,300 S/cm
           trodes.)                                                       Sewage             500 to 2,000 S/cm
                                                                          Distilled water    3.3 to 4 S/cm max.
! Caution

In case of the 61F-HSL ultra high-sensitivity variable model,
malfunction due to electric corrosion may occur in the DC elec-
trode circuit. Be careful not to use the product in such a way
where current constantly flows between electrodes.

Table 1 Water Resistivity Values
(Japanese Reference Values)

       Water type                   Resistivity
City water         5 to 10 k S cm
Well water         2 to 5 k S cm
River water        5 to 15 k S cm
Rain water         15 to 25 k S cm
Sea water          0.03 k S cm
Sewage             0.5 to 2 k S cm
Distilled water    250 to 300 k S cm min.
61F                                                                                                              61F

Precautions                                                                 Consider the Response Times

     ! WARNING                                                              The 61F requires a response time not exceeding 80 ms for opera-
                                                                            tion or 160 ms for reset. Take these response times into account in
   Never touch any of the terminals. Doing so may result in elec-           cases where precise sequence control is required.
   tric shock.
                                                                            Consider the Liquids to Be Controlled
   Never attempt to disassemble the 61F or touch the inside of
   the 61F while the power is being supplied. Doing so may result           The 61F cannot be used for any liquid that has almost no conductiv-
   in electric shock.                                                       ity such as sewage containing oil.

  Correct Use                                                               The 61F cannot be used for any flammable liquid such as gasoline,
                                                                            kerosene, or heavy oil.
Use a Power Supply with Minimal Voltage Fluc-
tuation                                                                     Do Not Share Electrodes

Avoid connection to a power supply with a voltage fluctuation great-        Do not connect a single Electrode to more than one 61F. If the
er than or equal to +10% or --15%.                                          phases of the 8-VAC Electrode-circuit power supplies are opposite
                                                                            to each other, as shown in Fig. 1, an internal close circuit (return cir-
Consider the Ambient Temperature                                            cuit) is created (indicated by the arrows). The 61F may malfunction
                                                                            regardless of the liquid level when the 61F power is turned ON. This
Do not install the 61F where it may be exposed to a temperature of          problem can be overcome by matching the power supply phases, as
55C or more and a humidity of 85% or more. In particular, install the      shown in Fig. 2, but in this configuration the internal impedance of
61F away from heat-generating equipment incorporating coils or              the 61F calculated from the Electrode will be approximately half as
windings. Also avoid locations subject to high humidity or corrosive        large as the internal impedance of a single 61F. The same phenom-
gases.                                                                      enon can occur if multiple (not shared) Electrodes, connected to
                                                                            separate 61F units, are installed close together inside a single tank.
Avoid Vibration and Shocks                                                  Maintain sufficient clearance between Electrodes connected to
                                                                            separate 61F units so that they do not interfere with each other.
Do not subject the 61F to vibration or shocks which can cause chat-         Common leads, however, can be connected to the ground Elec-
tering problems. Do not install the 61F near contactors that gener-         trode.
ate severe shocks while the contactors are in operation.
                                                                            Fig. 1 Internal Closed Circuit
Do Not Test with a Megaohmmeter
                                                                            8 VAC                         8 VAC
During insulation resistance measurements, never apply the me-
gaohmmeter across the Electrode terminals.                                  Fig. 2 Match Phases

Use Self-holding Electrodes                                                  T SR

Use Self-holding (E2) Electrodes when contactor open/close con-                                  61F
trol is carried out. If E1 Electrodes are used, ripples on the liquid sur-
face can cause incorrect contactor operation and damage to the                     So                 S2
contacts.
                                                                                                 61F
Be sure to turn OFF the power supply before replacing the plug-in
models.                                                                            So                 S2

Short Wiring in Electrode Circuit

Keep the wires connecting the 61F to Electrode Holders as short as
possible. If long leads are used, the floating capacity of the leads,
and abnormal surges or noise in the Electrode circuit can cause
malfunctions.

The thicker the cables, the shorter the permitted wiring length. The
length of the cable connecting the 61F and Electrode described in
the 61F datasheet will be available if a 600-V VCT0.75-mm2, 3-core
cabtire cable is used. Test results indicate that the actual wiring
length using VCT 3.5-mm2, 3-core cable laid over the ground is 50%
of the indicated length for general-purpose applications and 80% of
the indicated length for long-distance applications. When selecting
the cable specification, remember that the wiring length is further
decreased for underground cables and larger diameter cables be-
cause of the increased floating capacity with the ground.

Keep Power Cables Separate from the Electrode
Circuit

Do not pass the leads for the Electrode circuit through the same
duct, or near to, high-tension cables or power cables. This can
cause noise which leads to malfunctions.

Ground Correctly

Ground the common Electrode terminal to reduce the effects of
noise.

Use a Surge Suppressor

Connect a 61F-03B(-04B) Surge Suppressor with the 61F Elec-
trode terminals to protect the circuit from surges. This is particularly
important in lightning-prone areas. To further improve protection,
install a commercial surge suppressor in the power supply to elimi-
nate surges in the power system.
61F                                                                                                                         61F

  Cautions on Electrodes                                               Keep Electrodes Clean

Be sure to disconnect the 61F before conducting a insulation test on   Lift the Electrodes and remove the surface film with fine sandpaper
the Electrode circuit for inspection purposes.                         about 6 months after installation. Subsequently, repeat this cleaning
When cutting an Electrode, be sure to chamfer cut surfaces of the      once or twice per year.
electrode.                                                             Cleaning is particularly important for Electrodes used in a liquid con-
                                                                       taining large amounts of dirt or slime, which can build up into an in-
Maintain a Clearance Between Electrodes                                sulating film on the Electrode surface and cause malfunctions.
                                                                       Clean the surface insulating film from Electrodes used in this envi-
Maintain sufficient clearance (normally 1 m) between Electrodes in     ronment once every three months. Use a pipe, as shown in the dia-
sea water or contaminated water. Use the 61F-jD (or -jND) low-         gram below in situations where the water contains large amounts of
sensitivity models if this clearance is difficult to maintain.         dirt.
                                                                       Use a pipe as shown to keep dirt and oil films from the Electrode in
        1m             1m                                              situations where the liquid is highly contaminated with dirt and oil,
                                                                       such as sewage holding tanks.
Long Ground Electrode
                                                                                                                                PS-jS
The Electrodes are mounted in sets of three. Connect the shortest
Electrode to E1, the medium Electrode to E2 and the longest Elec-                                                                   Approx. 10-dia. air vent hole
trode to E3. The longest Electrode, E3, must be at least 50 mm long-
er than the other Electrodes.                                                                                                       4 dia. min. pipe

               E1                                                      Bottom of tank    Thickness of contaminants
                                                                                         collected between cleanings
             E2    50 mm min.
        E3

Consider the Operating Level                                           Use a pipe at least 4 inches in diameter.

Due to the liquid type and fluctuations in the power supply voltage,   Cut off the end of the pipe at an angle to clear the estimated amount
the operating level may fluctuate to a small degree from the level at  of contaminants accumulating at the bottom of the tank.
which the liquid surface makes contact with the Electrode tip.
                                                                       Drill an approximately 10-dia. vent hole at the top of the pipe.
Use Separators
                                                                       Using an Anti-ripple Pipe:
If the Electrode length reaches 1 m min., insert Separators at the     Use an anti-ripple pipe as shown below in cases where large ripples
joint positions to prevent the Electrodes touching each other in the   are produced by a rapid fluid flow rate.
liquid.
                                                                                         PS-jS

                                                                       4-dia. min. pipe  Approx. 10-dia. air vent hole

                   Electrode Holder

            Separator                                                                    Drill at least four 6 to 10-dia. holes
                                                                                         as opposing pairs at the tip position
                                                                                         of each Electrode.

Take Care When Taping the Electrodes                                   Use a pipe at least 4 inches in diameter.

When applying vinyl tape to the Electrodes to prevent them touching    To improve liquid circulation inside the pipe, drill at least four 6 to
each other in the liquid, leave at least 100 mm at the end of the rod  10-dia. holes as opposing pairs at the tip position of each Electrode.
untaped. Do not tape to the very tip.
                                                                       Drill an approximately 10-dia. vent hole at the top of the pipe.
                           Tape
                                                                       Follow the information above with regard to using Electrodes.
100 mm
                                                                         Cautions on Electrode Holders
Mount Electrodes Vertically
                                                                       Do not mount horizontally or a malfunction may occur.
Install the Electrodes vertically to avoid the accumulation of slime
which can form an insulating layer on the Electrode surface.           BS and BF Electrode Holders

                                                                       When installing the Electrodes, first tighten the connection nut with
                                                                       a wrench before tightening the Electrodes and lock nut. Tightening
                                                                       the terminals or other parts can lead to damage of the insulating
                                                                       parts due to tightening torque.

                                                                       When mounting a BS-1 Electrode Holder to a boiler, wrap Teflon
                                                                       tape 2 or 3 times around the mounting position and use the gasket
                                                                       supplied.

                                                                       Always apply the F03-11 Protective Cover if the BF-3 (-4 or -5) is
                                                                       used outside or in a position subject to water splashes or where dust
                                                                       or dirt can settle. Foreign matter on the Electrode insulation can
                                                                       cause electrical leakage and malfunctions.
61F                                                                                             61F

  Inspecting the Electrode Circuits                                                    Measuring the Resistance Between
                                                                                     Electrodes
In cases where the Electrodes cannot be withdrawn to test the Elec-
trode circuit, a tester can be used to measure the resistance be-                    Measure the resistance between the Electrodes if the wiring is cor-
tween the Electrode and ground, as shown in the diagram below.                       rect but the 61F does not operate. Measure with a voltmeter using
The measured resistance value indicates the length, contact condi-                   the voltage drop method, as shown below.
tion, and mounting condition of the Electrode. For example, the se-
quence of Electrodes ordered from low measured resistance to high                    E1
is E3 (long), E2 (medium), and E1 (short).
Follow the guidelines below to use this test method.                                 E3     mA

   1. Detach the leads from the 61F.                                                     V
   2. Measure the conducting status with the tank full. (The water
                                                                                                                                                      E1
        level must be at E1 minimum.)
   3. Measure the insulating status with the tank empty. (The water                                                                      E3

        level must be at E3 maximum.)                                                     mA An ammeter able to read approximately 1 mA

                        E1 E2 E3                                                                     with as low an impedance as possible.

                                                                      Tester Ground        V A voltmeter able to read a value of several volts

                                                      E1 E2 E3                                       with as high an impedance as possible.

                                                          Tester Ground              The resistance between Electrodes (resistance of liquid between
                                                                                     E1 and E3) is given by the following equation.
                                                                                     R = V/I
                                                                                     Where,
                                                                                     R: resistance of liquid between Electrodes ()
                                                                                     V: voltmeter indicated voltage (V)
                                                                                     I: ammeter indicated current (mA)
                                                                                     Select the 61F model according to the R (resistance) value.

                                                                                       Inspecting the 61F-11N Relay Unit

                                                                                     Apply the specified power supply voltage with the Relay Units con-
                                                                                     nected to the 61F. Refer to the connection diagrams (internal wiring
                                                                                     diagrams) and short the 61F ground terminal to the operating termi-
                                                                                     nal of each Relay Unit. Check the operation of the relay output con-
                                                                                     tacts with a tester. With the 61F-11 models, the indicator will be lit
                                                                                     when the Relay Unit operates.
Water Leak Alarm/Detector                                               61F-WLA/-GPN-V50

Eliminate Problems Caused from Water
Leakage

0 to 50 k variable operating resistance to detect                                   RC
virtually any liquid.
                                                     When ordering, to complete the part number, be sure to specify the
Two types available: Water Leak Alarm (61F-WLA)      desired operating voltage.
and plug-in Water Leak Detector (61F-GPN-V50).
                                                         Example: 61F-WLA [120/240 VAC]
24 VAC interelectrode voltage causes no electrolyt-                                                      Desired supply voltage
ic corrosion.

Suggested applications include computer room,
power plant, factory, library, warehouse, and
basement use.

Conforms to EMC/IEC Standards (61F-GPN-V50).

Approved by UL/CSA (61F-GPN-V50)

Ordering Information

Water Leak Alarm     61F-WLA
Water Leak Detector  61F-GPN-V50

Specifications

Ratings/Characteristics                          Water Leak Alarm                    Water Leak Detector
                                  61F-WLA                               61F-GPN-V50
                          Item    100/200, 110/220, 120/240 VAC         100, 110, 120, 200, 220, 240 VAC
Model                             24 VAC
Supply voltage                    3 mA (AC) max.                        3.2 VA max.
Interelectrode voltage            8.0 VA max.
Operating current                 Variable (0 to 50 k)                  Scale 0: 10 k
Power consumption                 Scale 0: 10 k                         Scale 50: 10 k (see note 2)
Sensitivity                       Scale 50: 10 k (see note 2)          3 A 250 VAC, DPDT cos=1
Error (against the scale)         3 A 250 VAC, SPDT cos=1               1 A 250 VAC, DPDT cos=0.4
                                  1 A 250 VAC, SPDT cos=0.4             Provided (Operation indicator)
Contact ratings                   Provided (Power and Leak indicators)  Not provided
                                  Provided                              Not provided
Indicator                         Provided
Alarm buzzer                      --10C to 55C
Test switch
Ambient temperature

Note: 1. For detecting leakage of water with high resistivity, use 61F-UHS or 61F-HSL ultra high-sensitivity models. (Refer to page 32.)
          2. The Detector may not operate around the setting value of "0." Adjust the sensitivity depending on the actual application.
61F-WLA/-GPN-V50                                                                            61F-WLA/-GPN-V50

Operation                                                                               Amplifier
                                                                                                 Relay
  Internal Circuit

61F-GPN-V50 Water Leak Detector

                                              Rectifier/                     Level
                                                                             detector
                                      24 VAC  smoothing                      switching
                                              circuit                        circuit

                     AC power source

                                      24 VAC                     Rectifier/
                                                                 smoothing
                                                                 circuit

                                              Sensitivity
                                              adjuster

                                                          Sensor cable

Operating Principle

When the two conductive cores of the Sensor Cable are contacted                                         Core
by a liquid, a weak alternating current (as small as 3 mA max.) flows                                   Core
across the cores. This current is amplified to operate a relay.
                                                                                        Liquid
In practice, leakage will be detected if water drops are present be-
tween the core wire and the Electrode (F03-15 Sensor Cable) or de-                              F03-26
tecting section (F03-16 Sensor Cable). (Refer to the specifications
on page 70)

Sensor Cable Protective Cover

               Item                           F03-25
Appearance

Suggested use                                             Adhesive                                      Adhesive
Construction
Comments             Fixes the F03-15 Sensor Cable on the floor              Fixes the F03-16 Sensor Cable on the floor
                     surface. Attach the sticker on a smooth surface. To     surface. Attach the sticker on a smooth surface. To
                     attach it on a concrete floor, use a concrete           attach it on a concrete floor, use a concrete
                     bonding agent.                                          bonding agent.
61F-WLA/-GPN-V50                                                                                        61F-WLA/-GPN-V50

Dimensions                                                                                     Three, M5 or
                                                                                               6-dia. mount-
Note: All units are in millimeters unless otherwise indicated.                                 ing holes
       61F-WLA Water Leak Alarm

       61F-GPN-V50 Water Leak Detector

  Accessories (Order Separately)

Connecting Sockets (for 61F-GPN-V50 Water Leak Detector)

PF113A-E Track-mounted Socket

                       Eleven, M3.5 x 5                                   Top view
                       sems screws

                                                                                    Two, M4 or 4.5 dia. holes  61F-
                                                                                               341            GPN-V50

              52 max.

                                                       31 max.                                                 PF113A-E
                                                                                                               PFC-N8 Holding
                                                                                                               Bracket

PL11 Back-connecting Socket              Two, 2 dia.                      Two, 3.5 dia. or M3
                                         holes                            mounting holes
                           51 max.
                                                                                 31 dia. hole                  61-                            Approx. 75
                                                                                                               GPN-V50

                       35 max.           Approx. 20.5                                                                   Approx. 16

                                                                                                               PL11

        Important:  Install the Water Leak Detector socket with the keyway facing down.

Sensor Cable                                                                        Crimped electrode pair Stainless steel core
                                                                                                                     (0.3 x 12 braided)
  F03-15

F03-16                                Sheath: Transparent vinyl chloride                                          Transparent vinyl chloride
                                      Core: Stainless steel SUS304                                     333 mm
                                                                                                       (3 electrode pairs per meter)
                                    Sheath: Transparent vinyl chloride
                                    Core: Stainless steel SUS304          Transparent vinyl chloride Detecting cutaway
61F-WLA/-GPN-V50                                                                                                      61F-WLA/-GPN-V50

Installation

Connections                                                                                             61F-GPN-V50 Water Leak Detector

61F-WLA Water Leak Alarm              Power                                                 Alarm LED
                                       supply
            Fuse                       LED                                Amplifica-
                                                                          tion circuit
                           Rectifica-               Level detec-                                                      To Sensor
                           tion/                    tion switch-                                                      Cable
                           smoothing                ing circuit
                           circuit                                                                      Alarm buzzer

                                                                                                                      Bottom view

                           Rectifica-                                                                                              AC power source
                           tion/
                           smoothing
                           circuit

                                       Test switch

100, 110, 120 VAC                                                         Sensor cable
power source

200, 220, 240 VAC
power source

Precautions                                                               (8) When measuring insulation resistance, do not conduct a meg-
                                                                               ger test between the electrode terminals.
  Correct Use
                                                                                      IV Cable                                   Sensor Cable
(1) Use only F03-15 or F03-16 Sensor Cable. Other water conduc-           0m
     tors may cause the Water Leak Alarm/Detector to malfunction,         10 to 150 m                                 200 m
     or not operate at all because of mismatched sensitivity.             200 to 300 m                                150 m
                                                                          350 to 400 m                                100 m
(2) Place the Sensor Cable at a location where water leakage is                                                       50 m
     most likely to occur. For example, consider the following loca-
     tions:                                                               Note: IV cable: 2 mm2

    Under a raised floor; on the highest floor of a building; on the

         ceiling

    In the vicinity of an air conditioner, or on the floor near a

         humidifier

    On the floor near a feed-water pipe, conduit; hot-water pipe.

    On top of a power, or control panel

(3) Secure the Sensor Cable so that they touch the floor surface or
     the wall near a pipe arrangement. Cover the Sensor Cable with
     a F03-25 or F03-26 Protective Cover if they are installed at a
     location crowed with people. However, place the cover such a
     manner that water can easily reach the Sensor Cable.

(4) Keep the temperature at the installation site to within 55C. Do
     not install the Water Leak Alarm/Detector/Sensor cable in the
     proximity of heat-generating equipment (such as that having a
     coil or wire winding). Also, do not use it in a highly humid loca-
     tion, or at a location that is subjected to corrosive gases. Do not
     place the Water Leak Alarm/Detector side-by-side with a high-
     capacity contactor that produces an inrush current when it oper-
     ates, as such arrangement may cause chattering to occur, con-
     sequently causing a malfunction of the Water Leak Alarm/De-
     tector.

(5) Wiring distance of the Sensor Cable varies depending on the
     water quality. When using IV cables, wire the Sensor Cable to
     the length specified in the following table.

(6) Mount the 61F-WLA Water Leak Alarm/Detector on a sturdy
     wall surface which is not subjected to vibration or shock. Do not
     use double-sided adhesive tape, otherwise, the Detector may
     detach when the adhesive tape deteriorates due to aging.

(7) When wiring the Sensor on conductive objects like metal
     objects, use the F03-16.
61F-WLA/-GPN-V50                                                                         61F-WLA/-GPN-V50

NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.

                                      R  OMRON ON--LINE                                  OMRON CANADA, INC.

OMRON ELECTRONICS LLC                    Global -- http://www.omron.com                  885 Milner Avenue
                                         USA -- http://www.omron.com/oei                 Toronto, Ontario M1B 5V8
One East Commerce Drive                 Canada -- http://www.omron.com/oci
Schaumburg, IL 60173                                                                    416-286-6465

1-800-55-OMRON                           Specifications subect to change without notice  Printed in U.S.A.

Cat. No. F030-E1-8
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved