Conductive Level Controller

61F-GPN-BT/-BC

                                                                                                      CSM_61F-GPN-BT_BC_DS_E_3_1

Battery (24 VDC) allows use in locations
without AC power supply. AC sine-wave
voltage between electrodes enables stable
detection with no electric corrosion.

Outputs can be set to self-hold at ON or OFF using special cir-
cuits.

Adjustable sensitivity, with an operating resistance range of 0 to
100 k, allows use for a wide variety of liquids.

Relay contact chattering conventionally caused by waves elimi-
nated using open collector output, reducing contact wear.

Meets CE marking and is a UL recognized component.

          Refer to Safety Precautions for Floatless Level
          Controllers.

Features

The 61F can now run on DC power to allow energy savings, greater safety, and use in
emergency situations.

Combines DC Power                                                         Open Collector Output

Supply with AC Sensing         Oscillator                                 Signals can be used as      Chattering
Method                         circuit                                    direct input for a PLC.
AC sine-wave signals are                                                  PNP output is also
                                               Detector                                                                                Load
                                               circuit

sent to electrodes using a                                                possible using the

built-in DC-AC converter,                                                 connection method.

preventing electric

corrosion and ensuring

safety.

Supports Multi-channel            Upper limit                             Same Wiring for Supply      Drainage                        Supply
Sensing                        Mid-point                                  and Drainage                control                         control
                            Lower limit                                                                                  Short-circuit
Power supply circuits and                                                 Supply control and                      Valve
detection circuits are                                                    drainage control can be                                                 Pump
isolated, allowing more                                                   performed with the same
than one Controller to be                                Control output   wiring (short terminals 7
used in the same tank.                                   is possible for  and 8 for supply control).
                                                         upper limit,     This makes it easy to
                                                         mid-point, and   perform wiring and
                                                         lower limit.     confirm connection.

Ordering Information

                 Product name                  61F-GPN-BT 24VDC           Model number
Conductive Level Controller                    Open collector (NPN)                  61F-GPN-BC 24VDC
                                               PF113A-E                              Relay contact (SPST-NO)
Front Socket                                   (See note.)
Electrode Holder

Note: A variety of Holders are available to suit different types of application. For details, refer to 61F Floatless Level Controller
        (F030-E1-8).

                                                                                                                                                        1
                                                                                                                    61F-GPN-BT/-BC

Specifications

Ratings

                                                                         61F-GPN-BT                                 61F-GPN-BC

Rated voltage                                                24 VDC
Allowable voltage range
Interelectrode voltage                                       85% to 110% of the rated voltage
Operation resistance (See note 1.)
Error                                                        5 VAC max.
Release resistance
Switching between supply and drainage                        Variable (0 to 100 k)

Output specifications                                        For scale of 0: +10 k; For scale of 100: 10 k

Life expectancy                                              200% max. of the operation resistance

Accessories                                                  Terminals 7 and 8 open: Automatic drainage operation
Wiring distance (See note 2.)                                Terminals 7 and 8 shorted: Automatic supply operation

                                                             Open collector (NPN)                     Relay output, SPST-NO
                                                             30 VDC, 100 mA max.                      5 A, 240 VAC (Resistive load)
                                                             Leak current: 100 A max.                 5 A, 30 VDC

                                                             ---                                      Electrical: 100,000 operations min.

                                                                                                      Mechanical: 20,000,000 operations min.

                                                             Hold-down clip PFC-N8

                                                             100 m max.

Note: 1. The 61F may not operate at resistance settings close to zero. Adjust the sensitivity to match actual usage conditions.
        2. The figure for wiring distance above is for when 600-V 3-core cabtire cable with a cross-sectional area of 0.75 mm2 is used.

Characteristics

Ambient operating temperature -10 to 55C

Ambient operating humidity 25% to 85%

Insulation resistance                  100 M min. (at 500 VDC)

Dielectric strength (See note.) 2,000 VAC, 50/60 Hz for 1 minute

Power consumption                      2 W max.

Response time                          Operating: 1.5 s max.
                                       Releasing: 3.0 s max.

Note: The dielectric strength is measured between power terminals
        and electrode terminals, power terminals and output terminals,
        and between electrode terminals and output terminals.

Connections

Automatic Drainage Operation

       61F-GPN-BT

Open collector OUT+ 11                            5

output         OUT- 10                            6

Relay contact OUT+                                        4
output                             11

                             OUT-  10                                E1                Pump ON (OFF)
                                                                                       Pump OFF (ON)
           Supply/                 7 (See note.)                 E2
           drainage                                          E3
           selection               8   39
           terminals

Note:                            24 VDC
        The part within the dotted-line box is for the 61F-GPN-BC (relay-output type) only.

Automatic Water Supply Operation

Short terminals 7 and 8 for automatic water supply operation. (Operation shown in parentheses in the diagram above.)

                                                                                                                                              2
                                                                        61F-GPN-BT/-BC

Reading Signals for the Liquid Level Only (No Control)

Only E1 and E3 are used. Output will turn ON when the liquid level reaches E1 if terminals 7 and 8 are open, and will turn OFF if terminals 7 and
8 are closed. Also, to take signals for liquid level at several points, use terminal 4 as a common for all of the Controllers and use terminal 5 of each
Controller as an electrode.

Note: If terminals 7 and 8 are shorted, operation of the 61F relay is "de-energizing" (i.e., energized normally and de-energized when liquid is
        present across the electrodes). Therefore, if the power supply connected across terminals 3 and 9 is interrupted, the output from terminals
        10 and 11 will turn OFF, enabling detection of power interruptions.

Dimensions                                                                                           Use a PFC-N8 Mounting Bracket to mount the
                                                                                                     Level Controller to a PF113A Rail-mounted
61F-GPN-BT/-BC                                                                                       Socket.

                                      49.4                                                                                          PFC-N8
                                                    38
                                                                    61F-GPN                                  4

                                                                    -BT/-BC
                                                                                         101

                                                        70                                              Approx. 83
                                                           84                                              80

                                                                    PF113A (Order Separately)

                                                                                                        4.5

                                                                                                     6       t = 0.3

                                                                                                     Note: PFC-N8 Mounting Bracket (provided with
                                                                                                             the Level Controller)

Application Examples                                                Meet safety standards by         Liquid level control for waste-heat
                                                                    using DC power supply for        recovery boilers in co-generation
                                Drainage control for semiconductor  all devices in a panel.          systems.
                                wafer cleaning installations.

         Applications

                                                                             ON OFF

Liquid level control for solar                          Liquid level control for remote              Cut costs by using the 61F in situations
power generation systems.                               regions without AC power supply.             where ultrasonic/electrostatic capacity
                                                                                                     level controllers were used because
                                                                                            Battery  only DC power supply was available.

                                                                                                                                              Number of
                                                                                                                                              controllers
                                                                                                                                              required:

                                                                                                                                              2

                                                                                                                                              1

                                                                                                                                                           3
Safety Precautions                                                                           61F-GPN-BT/-BC

Refer to Safety Precautions for Floatless Level Controllers.            Correct Use

General Precautions                                                     Mounting

Before using the Controller under conditions not described in the rel-  Mount to a panel of thickness 1 to 5 mm.
evant documents or applying the Controller to nuclear control sys-      Do not mount the Controller in the following places.
tems, railroad systems, aviation systems, vehicles, combustion          Locations subject to strong vibrations or shocks.
systems, medical equipment, amusement machines, safety equip-            Locations outside the specified temperature and humidity ranges,
ment and other systems, machines, and equipment that may have a
serious influence on lives and property if used improperly, consult       or locations prone to condensation. (The Controller detects high
your OMRON representative.                                                impedances. Do not use in locations subject to high humidity lev-
                                                                          els.)
Make sure that the ratings and performance characteristics of the       Locations subject to dust.
Controller are sufficient for the systems, machines, and equipment       Locations subject to corrosive gases (in particular, sulphurized gas
and be sure to provide the systems, machines, and equipment with          or ammonia gas).
double safety-mechanisms.                                                Outdoors, or in locations subject to direct sunlight.
                                                                         Near devices that generate strong, high-frequency noise (e.g.,
Safety Precautions                                                        high-frequency welders, machines).

In order to ensure safe operation, be sure to observe the following
points.

Use a power supply voltage within the specified range.
Do not use the Controller in locations subject to flammable gases

  or objects.
Insert the Socket until it securely clicks into place.
Do not short the load connected to the output terminals.
Do not connect the power supply in reverse.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                  In the interest of product improvement, specifications are subject to change without notice.

                                                                         4
                                                       Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                            Application Considerations

SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

       Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

       Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
           safety equipment, and installations subject to separate industry or government regulations.

       Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                       Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

OMRON Corporation                                                                                                                                        2010.3
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                                                   (c)Copyright OMRON Corporation 2010 All Right Reserved.
http://www.ia.omron.com/
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved