电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

61F-GP-N AC110

器件型号:61F-GP-N AC110
器件类别:热门应用    机电/工控/自动化   
文件大小:10389.28KB,共15页
厂商名称:All Sensors
标准:
下载文档

器件描述

控制器 level controller

参数
制造商: Omron
产品种类: 控制器
RoHS:

61F-GP-N AC110器件文档内容

Floatless Level Switch (Compact, Plug-in Type)

61F-GP-N@

                                                                                                   CSM_61F-GP-N__DS_E_4_1

Space-saving Design Ideal for Control Panel
Downsizing. Easy Maintenance.

Compact: 49.4 38 84 mm (HWD).
Easy identification of operating status with LED operation

indicator.
Independent DPDT contacts on 11-Pin Models.
CE marking (N and N8 models) and UL/CSA compliance

(N8 models).

Refer to Safety Precautions for Floatless Level
Controllers.

Model Number Legend                                                                          Position of LED indicator

61F-GP-@@             1. No. of Pins   2. Type

                  12      N: 11 pins             Blank: General-purpose
                          N8: 8 pins
                                                 L 2KM: Long-distance (for 2 km)

                                                 L 4KM: Long-distance (for 4 km)

                                                 H: High-sensitivity

                                                 D: Low-sensitivity

                                                 R: Two-wire

                                                 T:  High-temperature

Ordering Information

     Type           General-purpose       Long-distance (for 2 km)       Long-distance (for 4 km)
11-pin                     Model                       Model                          Model

           61F-GP-N                    61F-GP-NL 2KM                  61F-GP-NL 4KM

     Type           High-sensitivity             Low-sensitivity                    Two-wire
11-pin                     Model                       Model                          Model

           61F-GP-NH                   61F-GP-ND                      61F-GP-NR

     Type       Tropical environments          High-temperature
8-pin                      Model                       Model

           61F-GP-N-TDL                61F-GP-NT

     Type           General-purpose       Long-distance (for 2 km)       Long-distance (for 4 km)
8-pin                      Model                       Model                          Model

           61F-GP-N8                   61F-GP-N8L 2KM                 61F-GP-N8L 4KM

     Type           High-sensitivity             Low-sensitivity                    Two-wire
8-pin                      Model                       Model                          Model

           61F-GP-N8H                  61F-GP-N8D                     61F-GP-N8R
           61F-GP-N8HY

Note: When ordering, specify the desired operating voltage at the end of the model number.
        Example: 61F-GP-N [220 VAC]
                                                       Desired supply voltage

                                                                                                                           1
                                                                                                                  61F-GP-N@

Compact Plug-in Models (11-pin Type)

Specifications

        Item           General-purpose          High-            Long-distance High-sensitivity Low-sensitivity          Two-wire
                           Controller       temperature                                                                 Controller
                                                                 Controllers      Controller        Controller
                            61F-GP-N         Controller                                                                 61F-GP-NR
                                                              61F-GP-NL 2KM       61F-GP-NH         61F-GP-ND
                                            61F-GP-NT             (for 2 km)      (see note 4)

                                                              61F-GP-NL 4KM
                                                                  (for 4 km)

Controlling materials  For control of ordi- For control of ordi- For control of ordi- For control of liq- For control of liq- For control of ordi-
and operating condi-
tions                  nary purified water nary purified water nary purified water uids with high spe- uids with low spe- nary purified water

                       or sewage water or sewage where in cases where the cific resistance cific resistance or sewage water

                                         operating ambient distance between such as distilled such as salt water, used in combina-

                                         temperature is sewage pumps water                          sewage water, tion with Two-wire

                                         high.                and water tanks or                    acid chemicals, al- Electrode Holder

                                                              between receiver                      kali chemicals (incorporating a

                                                              tanks and supply                                    resistor of 6.8 k)

                                                              tanks is long or

                                                              where remote con-

                                                              trol is required.

Supply voltage         24, 100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz

Operating voltage      85% to 110% of rated voltage
range

Interelectrode voltage 8 VAC

Interelectrode current Approx. 1 mA AC max.                                       Approx. 0.12 mA Approx. 1 mA AC max.
                                                                                  AC max.

Power consumption Approx. 3.5 VA max.

Interelectrode operate 0 to approx. 4 k  0 to approx. 4 k     0 to approx. 1.3 k Approx. 10 k to    0 to approx.  0 to
resistance                                                                                          1.3 k         approx. 2 k
                                                              (for 2 km)          approx. 40 k

                                                              0 to approx. 0.5 k (see note 3)

                                                              (for 4 km)

Interelectrode release Approx. 15 k to   Approx. 15 k to      4 k to   (for 2     Approx. 100 k to  Approx. 4 k to   Approx. 15 k to
                                                              km)                                                            
resistance                                                    2.5 k to   (for 4
                                                              km)

Response time          Operate:80 ms max.
                       Release:160 ms max.

Cable length           1 km max.         600 m max.           2 km max.           50 m max.         1 km max.     800 m max.
(see note 1)                                                  4 km max.

Control output         1 A, 250 VAC (Inductive load: cos = 0.4)
                       3 A, 250 VAC (Resistive load)

Ambient temperature Operating:10 to 55C (10 to 70C for high-temperature controller)

Ambient humidity       Operating:45% to 85% RH

Insulation resistance 100 M min. (at 500 VDC)
(see note 2)

Dielectric strength    2000 VAC, 50/60 Hz for 1 min.
(see note 2)

Life expectancy        Electrical: 100,000 operations min.
                       Mechanical: 5,000,000 operations min.

Weight                 Approx. 155 g

Accessories            Hold-down clip PFC-N8

Note: 1. The length when using completely insulated, 600-V, 3-conductor (0.75 mm2) cabtire cables. Usable cable lengths will become shorter as
            the cable diameter or number of conductors becomes larger. For details, refer to Safety Precautions for Floatless Level Controllers.

        2. The insulation resistance and dielectric strength indicate values between power terminals and Electrode terminals, between power
            terminals and contact terminals, and between Electrode terminals and contact terminals. For details, refer to Safety Precautions for
            Floatless Level Controllers.

        3. Possible to use with 15 k or less, however, this may cause reset failure.

        4. 61F-GP-NH High-sensitivity Controller uses advanced operation.
            When the power supply voltage is applied, if there are some liquids between the electrodes (ground and operation electrodes), the inter-
            nal relay will not operate.
            When the power supply voltage is applied, if there are no liquids between the electrodes (ground and operation electrodes), the internal
            relay will operate.
            If the advanced operation does not satisfy applications, consider using 61F-N8HY controller which uses sequential operation.

                                                                                                                                                      2
Internal Circuit Diagrams                                                                       61F-GP-N@

61F-GP-N/-NT/-NL/-ND                         61F-GP-NH                           61F-GP-NR

Power supply                               Power supply                          Power supply
                                                                                                     24 V Control circuit
       24 V Control circuit                       24 V Control circuit                                8V
                                                                                                                             U
           8V  (See note.)                        8V        (See note.)                                                              U

               U             U                           U               U

3 9 4 5 11 10 1 7 6 8                      39     4 5 11 10 1 7 6 8              39                    4   5 11 10 1
                                                                                                           E1 Ta1 Tc1 Tb1
S0 S1  E3      E1 Ta1 Tc1 Tb1 Ta2 Tc2 Tb2  S0 S1  E3 E1 Ta1 Tc1 Tb1 Ta2 Tc2 Tb2  S0 S1                 E3

Note: When applying a self-holding circuit, short between terminals 5 and 6 and use terminal 7 as E2.

                                                                                                                                        3
                                                                                                                                          61F-GP-N@

Connections                                                                                                 Compact, Plug-in Type

Automatic Water Supply and                                                                                   61F-GP-N
Drainage Control

                                                                                                                     Dimensions:
                                                                                                                     page 14

                    Automatic Water Supply Control                                           Automatic Drainage Control
Connections
                                                                              Connections

   Commercial Voltage       61F-GP-N                                             Commercial Voltage         61F-GP-N
            RST                                                                           RST
                                          8765                                                                    8765
MCCB                                                                          MCCB
                                                     U                     4                                                 U                      4

                                               0V    24 V        Control   U                                           0V          24 V   Control      U
                                                                  circuit                                                                  circuit
                                             Power                                                                   Power
                                             supply  8V                                                              supply        8V

                                                         U                                                                             U

                                          3                                9                                      3                                 9

                            10 11 1 2                                                                             10 11 1 2

Contac-                     (See note.)                                       Contac-                (See note.)
tor                                                                           tor
                                                                 PS-3S
Motor                                                                         Motor
protection                  Water supply     Water           E1  Stop         protection             PS-3S
relay                       source             tank  E3 E2       Start        relay
                                                                                                     Waste-                  Start

                                                                                                     water            E1

                                                                                                     tank    E3 E2           Stop
                                                                                                     P
            M            P                                                                M

                                                                                                                                             Reservoir

Note: Be sure to ground the common Electrode E3 (the                          Note: Be sure to ground the common Electrode E3 (the
        longest Electrode).                                                           longest Electrode).

        Connection Sockets                                                            Connection Sockets
        PF113A (Front-connecting)                                                     PF113A (Front-connecting)
        PL11 (Rear-connecting)                                                        PL11 (Rear-connecting)

Connect terminal 1 to the contactor's coil terminal.                          Connect terminal 1 to the contactor's coil terminal.

Note: The power supply depends on the specifications of the                   Note: The power supply depends on the specifications of the
        model.                                                                        model.

Principles of Operation                                                       Principles of Operation

                 Water
                 supply
            P

            Pump OFF                E1               (Indicator ON)                       Pump ON                    E1      (Indicator ON)

            Pump ON             E2                   (Indicator OFF)                      Pump OFF                           (Indicator OFF)
                            E3
                                                                                                                 E2                P
                                                                                                             E3                           Water drainage

The pump stops when the water level reaches E1 (indicator ON)                 The pump starts when the water level reaches E1 (indicator ON)
and starts when the water level drops below E2 (indicator OFF).               and stops when the water level drops below E2 (indicator OFF).

                                                                                                                                                          4
Liquid Level Indication                                                                               61F-GP-N@
(Connection Example)
                                                                                           Compact, Plug-in Type

                                                                                           61F-GP-N

                                                                                               Dimensions:
                                                                                               page 14

                                                             Liquid Level Indication

Connections                      Lower limit                    Intermediate                       Upper limit

Commercial Voltage           61F-GP-N                       61F-GP-N                      61F-GP-N
          RST
                              8765                           87 65                         87 65
                        MCCB
                                        U      4                       U      4                        U                   4

                                 0V     24 V   Control   U      0V     24 V   Control   U          0V  24 V   Control         U
                                                circuit                        circuit                         circuit

                              Power     8V                   Power     8V                  Power       8V

                              supply        U                supply        U               supply          U

                              3                9             3                9            3                               9

                              10 11 1 2                      10 11 1 2                     10 11 1 2

                                               (See note.)                                                                 PS-4S

                                               Water supply                                Water                       E1     Upper limit
                                                   source                                    tank                 E2          Intermediate
                                                                                                            E3                Lower limit
                                                                                                       E4
M                                       P

   Note: The power supply phases (terminals 3 to 9) can be matched to use the same ground for the
           common Electrode (the longest Electrode, terminal 4).

  Principles of Operation
Terminals 6 and 7, and terminals 10 and 11 on the lower -limit 61F-GP-N are shorted when the water level reaches E3 (indicator ON).
Terminals 6 and 7, and terminals 10 and 11 on the intermediate 61F-GP-N are shorted when the water level reaches E2 (indicator ON).
Terminals 6 and 7, and terminals 10 and 11 on the upper-limit 61F-GP-N are shorted when the water level reaches E1 (indicator ON).

                                                                                                                                            5
Replacing 61F-G3N Functions (Automatic Water                                                                                    61F-GP-N@
Supply Control with Abnormal Water Increase and
Water Shortage Alarms)                                                                                               Compact, Plug-in Type

                                                                                                                     61F-GP-N

                                                                                                                         Dimensions:
                                                                                                                         page 14

                                                                Replacing 61F-G3N Functions

Connections

                            Water shortage                              Pump control                                             Full tank

Commercial Voltage          61F-GP-N                                    61F-GP-N                                     61F-GP-N
       RST
                            8765                                        87 65                                        87 65
                      MCCB
                                            U3    4                                U2       4                                    U1             4

                            0V              24 V  Control   U3          0V         24 V     Control   U2                     0V  24 V           Control    U1
                                                   circuit                                   circuit                                             circuit

                            Power           8V                          Power      8V                                Power       8V

                              supply            U3                         supply      U2                              supply        U1

                            3                            9              3                       9                    3                       9

                            10 11 1 2                                   10 11 1 2                                    10 11 1 2

                            PL Lower limit        B Alarm                                                     PL Upper limit

             Contactor                              (See note.)                                                                                                PS-5S
   Motor protection
   relay                                                  Water supply                                               Water                             E1      Full tank
                                                               source                                                  tank                       E2           Stop
M
                                            P                                                                                               E3                 Start
                                                                                                                                      E4                       Water shortage
                                                                                                                                 E5

Note: The power supply phases (terminals 3 to 9) can be matched to use the same ground for the common Electrode
        (the longest Electrode, terminal 4).

  Principles of Operation                                                   Water supply                                  LH B
                                                                        P                                     Upper
The pump stops when the water level
  reaches E2 (U2 indicator ON) and starts                                    Pump OFF                         limit  (U1 indicator ON)
  when the water level drops below E3 (U2
  indicator OFF).                                                                                         E1

If the water level rises to E1 for any reason,                                                                             (U2 indicator ON)
  the upper-limit indicator turns ON and the
  alarm sounds (U1 indicator ON).                                                                         E2
  If the water level drops below E4 for any
  reason, the lower-limit indicator turns ON                                       Pump ON                           (U2 indicator OFF)
  and the alarm sounds (U3 indicator OFF).
                                                                                                   E3
                                                                                                              Lower (U3 indicator OFF)
                                                                                                E4
                                                                                            E5                limit  LL B

                                                                                                                                                                               6
                                                                                                                                      61F-GP-N@

Two-Wire Connections                                                                                                  Compact, Plug-in Type
Automatic Water Supply and Drainage Control
                                                                                                                      61F-GP-NR

                                                                                                                         Dimensions:
                                                                                                                         page 14

                    Automatic Water Supply Control                                                       Automatic Drainage Control

Connections                                                                          Connections

Commercial Voltage        61F-GP-NR                                                  Commercial Voltage          61F-GP-NR
          RST                                                                                  RST

                                                            5                                                                                    5

MCCB                                                                                 MCCB

                                                            4                                                                                    4

                                      0V          24 V  Control    U                                                          0V      24 V  Control      U
                                                         circuit                                                                             circuit

                                     Power        8V                                                                          Power   8V

                                     supply                                                                                   supply

                                                  U                                                                                   U

                              3                           9                                                              3                            9

                              10 11 1 2                                                                                  10 11 1 2

Contac-                              (See note.)                                       Contac-
tor                                                                                    tor
                                                                             PS-3SR                      (See note.)
Motor                                                             R                  Motor
protection                                                                           protection
relay                  Water supply               Water               Stop           relay               Waste-       R       PS-3SR
                           source                   tank              Start                              water
                                                                  E1
                                                          E3 E2                                          tank

                                                                                                                 E3 E2   E1

            M       P                                                                            M       P

                                                                                                                                                      Reservoir

Note: Be sure to ground the common Electrode E3 (the                                 Note: Be sure to ground the common Electrode E3 (the
        longest Electrode).                                                                   longest Electrode).

        Connection Sockets                                                                    Connection Sockets
        PF113 (Front-connecting)                                                              PF113 (Front-connecting)
        PL11 (Rear-connecting)                                                                PL11 (Rear-connecting)

Connect terminal 1 to the contactor's coil terminal.                               Connect terminal 11 to the contactor's coil terminal.

Note: The power supply depends on the specifications of the                          Note: The power supply depends on the specifications of the
        model.                                                                                model.

With 2-wire connections, only two wires are required between                        With 2-wire connections, only two wires are required between
  the 61F-GP-NR and Electrode Holder, but three wires are                              the 61F-GP-NR and Electrode Holder, but three wires are
  required for the Electrodes.                                                         required for the Electrodes.

The Electrode Holder must be specified for 2-wire connections.                      The Electrode Holder must be specified for 2-wire connections.
  (Resistance R is built into Electrode Holders for 2-Wire                             (Resistance R is built into Electrode Holders for 2-Wire
  Connections.)                                                                        Connections.)

Principles of Operation                                                              Principles of Operation

                  Water
                  supply

               P

            Pump OFF      E1                      (Indicator ON)                                 Pump ON         E1                   (Indicator ON)

             Pump ON                              (Indicator OFF)                                Pump OFF                             (Indicator OFF)
                                                                                                                                            P
                              E2                                                                                      E2                           Water drainage
                                  E3                                                                                      E3

The pump stops when the water level reaches E1 (indicator ON)                        The pump starts when the water level reaches E1 (indicator ON)
and starts when the water level drops below E2 (indicator OFF).                      and stops when the water level drops below E2 (indicator OFF).

                                                                                                                                                                   7
                                                                                                                        61F-GP-N@

Connection with Three-phase Four-line Circuit

When supplying power from N-phase to the Controller in three-phase four-line circuit, refer to the following diagrams.
Line voltage (R-S, S-T, or R-T): 380 or 415 VAC
Phase voltage (N-R, N-S, or N-T): 220 or 240 VAC

61F-GP-N@ 220 or 240 VAC

                                   61F-GP-N

                                       8765

                                              U             4

Power source                             0V      24 V Control circuit U
380 or 415 VAC
R S TN*                              220 or      8V
                                      240 V
                  Source voltage:                U
                  between 3 and 9  3
                                                           9

                                   10 11 1 2

A                                                           (See note 1)

Electromagnetic switch

                                                            Stop          *
                                                            Start
                                                                            (See note 2.)

                                     Water         E1
                                     tank
                                              E2
          Water supply source                           E3

       P
M

Note: 1. The diagram shows the connections for the water supply. When draining, change the connection from terminal 1 to terminal 11.
        2. Be sure to ground terminal 4.

                                                                                                                                       8
                                                                                                                    61F-GP-N@

Compact Plug-in Models (8-pin Type)

Specifications

Item               General-purpose Long-distance High-sensitivity                  Low-sensitivity         Two-wire          Variable
                                                                                      Controller          Controller       Sensitivity
                   Controller                    Controllers      Controllers                                              Controller
                                                                                     61F-GP-N8D          61F-GP-N8R
                    61F-GP-N8            61F-GP-N8L 2KM            61F-GP-N8H                                           61F-GP-N8-V50
                   61F-GP-N8Y                 (for 2 km)          61F-GP-N8HY
                   (see note 4)                                    (see note 4)
                                         61F-GP-N8L 4KM
                                              (for 4 km)

Controlling mate-  For control of ordi-  For control of ordi- For control of liq-  For control of liq-  For control of ordi- For control of cases
rials and operat-  nary purified water   nary purified water uids with high spe-   uids with low spe-   nary purified water where variable sen-
ing conditions     or sewage water       in cases where the cific resistance       cific resistance     or sewage water sitivity control is re-
                                         distance between such as distilled        such as salt water,  used in combina- quired such as
                                         sewage pumps and water                    sewage water, acid   tion with Two-wire detection of froth on
                                         water tanks or be-                        chemicals, alkali    Electrode Holder the surface of a liq-
                                         tween receiver                            chemicals            (incorporating a re- uid, control of soil
                                         tanks and supply                                               sistor of 6.8 k) moisture content,
                                         tanks is long or
                                         where remote con-                                                                         or detection of de-
                                         trol is required.                                                                         gree of water pollu-
                                                                                                                                   tion

Supply voltage 24, 100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz                                                    24, 110, 220 or
                                                                                                                        240 VAC; 50/60 Hz

Operating voltage 85% to 110% of rated voltage
range

Interelectrode     8 VAC                                          24 VAC           8 VAC                                24 VAC
voltage

Interelectrode     Approx. 1 mA AC max.                           Approx.          Approx. 1 mA AC max.                 Approx. 3 mA AC
current                                                                                                                 max.
                                                                  0.4 mA AC max.

Power consump- Approx. 3.5 VA max.
tion

Interelectrode op- 0 to approx. 4 k      0 to 1.3 k (for          Approx. 15 k to  0 to approx. 1.3 k 0 to approx. 2 k  0 to 50 k (Vari-
erate resistance                         2 km)                    approx. 70 k                                          able)
                                         0 to 0.5 k (for          (see note 3)
                                         4 km)

Interelectrode re- Approx. 15 k to   4 k to                       Approx. 300 k to Approx. 4 k to   Approx. 15 k to   Operating resis-

lease resistance                         (for 2 km)                                                                     tance +50 k max.

                                         2.5 k to  

                                         (for 4 km)

Response time Operate: 80 ms max.
                           Release: 160 ms max.

Cable length       1 km max.             2 km max.                50 m max.        1 km max.            800 m max.      50 m max.
(see note 1)                             4 km max.

Control output     1 A, 250 VAC (Inductive load: cos = 0.4)
                   3 A, 250 VAC (Resistive load)

Ambient tempera- Operating: 10 to 55C
ture

Ambient humidity Operating: 45% to 85% RH

Insulation resis- 100 M min. (at 500 VDC)
tance
(see note 2)

Dielectric         2000 VAC, 50/60 Hz for 1 min.
strength
(see note 2)

Life expectancy Electrical: 100,000 operations min.
                           Mechanical: 5,000,000 operations min.

Weight             Approx. 155 g

Accessories        Hold-down clip PFC-N8

Note: 1. The length when using completely-insulated, 600-V, 3-conductor (0.75 mm2) cabtire cables. Usable cable lengths will become shorter as
            the cable diameter or number of conductors becomes larger.

        2. The insulation resistance and dielectric strength indicate values between power terminals and Electrode terminals, between power ter-
            minals and contact terminals, and between Electrode terminals and contact terminals.

        3. Possible to use with 15 k or less, however, this may cause reset failure.

        4. 61F-GP-N8H/-N8Y High-sensitivity Controllers use advanced operation.
            When the power supply voltage is applied, if there are some liquids between the electrodes (ground and operation electrodes), the inter-
            nal relay will not operate.
            When the power supply voltage is applied, if there are no liquids between the electrodes (ground and operation electrodes), the internal
            relay will operate.
            If the advanced operation does not satisfy applications, consider using 61F-N8HY controller which uses sequential operation.

                                                                                                                                                         9
Internal Circuit Diagrams                                                                                        61F-GP-N@

61F-GP-N8/-N8L/-N8D/-N8HY                       61F-GP-N8H                                       61F-GP-N8R

Power supply                                 Power supply                                      Power supply
                     24 V Control circuit                                                                            24 V Control circuit
                                                                    24 V Control circuit                              8V

8 V (see note)                               24 V

                                                                                               2

  Note: 24 V for the 61F-GP-N8HY.            61F-GP-N8-V50

61F-GP-N8Y                                   Power supply
                                                                  24 V Control circuit
Power supply                                                       24 V
                       24 V Control circuit

                         8V

                                                                                          342

                                                                                                                                           10
                                                                                                                                      61F-GP-N@

Automatic Water Supply and Drainage Control                                                                    Compact, Plug-in Type

                                                                                                               61F-GP-N8

                                                                                                                   Dimensions:
                                                                                                                   page 14

               Automatic Water Supply Control                                                       Automatic Drainage Control

Connections                 61F-GP-N8                         87           Connections                 61F-GP-N8                      87

     Commercial Voltage            21                           U               Commercial Voltage            21                        U
              RST                                                                        RST

MCCB                                                                        MCCB

                                           0V     8V                                                                0V     8V
                                                                                                                           24 V Control circuit U
                                          Power   24 V        Control   U                                          Power
                                          supply               circuit                                             supply

                                             U                                                                        U

                                          34 5 6                                                                   34 5 6

Contac-                     (See note.)                                    Contac-                     (See
tor                                                                        tor                         note.)

Motor                                                         PS-3S        Motor
protection                                                                 protection
relay                       Water supply  Water           E1  Stop         relay                       PS-3S
                            source          tank  E3 E2       Start
                                                                                                       Waste-                  Start
                                                                                                       water          E1
                                                                                                       tank

            M            P                                                             M            P          E3 E2       Stop

                                                                                                                                           Reservoir

Note: Be sure to ground the common Electrode E3 (the                       Note: Be sure to ground the common Electrode E3 (the
        longest Electrode).                                                        longest Electrode).

        Connection Sockets                                                         Connection Sockets
        PF083A (Front-connecting)                                                  PF083A (Front-connecting)
        PL08 (Rear-connecting)                                                     PL08 (Rear-connecting)

Connect terminal 2 to the contactor's coil terminal.                      Connect terminal 3 to the contactor's coil terminal.
Note: The power supply depends on the specifications of the                Note: The power supply depends on the specifications of the

        model.                                                                     model.

Principles of Operation                                                    Principles of Operation

               Water
               supply
            P

            Pump OFF                      E1      (Indicator ON)                       Pump ON                 E1          (Indicator ON)

            Pump ON                               (Indicator OFF)                      Pump OFF            E2              (Indicator OFF)
                                                                                                       E3                        P
                                E2                                                                                                      Water drainage
                            E3

The pump stops when the water level reaches E1 (indicator ON)              The pump starts when the water level reaches E1 (indicator ON)
and starts when the water level drops below E2 (indicator OFF).            and stops when the water level drops below E2 (indicator OFF).

                                                                                                                                                        11
                                                                                                                                                    61F-GP-N@

Two-Wire Connections                                                                                                      Compact, Plug-in Type
Automatic Water Supply and Drainage Control
                                                                                                                          61F-GP-N8R

                                                                                                                                  Dimensions:
                                                                                                                                  page 14

                            Water Supply                                                                                Automatic Drainage

Connections                 61F-GP-N8R                                                  Connections                       61F-GP-N8R

     Commercial Voltage        21 87                                                          Commercial Voltage                21 87
              RST                                                                                     RST

MCCB                                                                                     MCCB

                                            0V         8V       U                                                                       0V    8V     U
                                                       24 V                                                                                   24 V
                                          Power                Control                                                                Power         Control
                                          supply               circuit                                                                supply         circuit

                            U                                                                                               U

               A               34 56                                                                                   34 56

                                                                                                       A

Contac-                                   (See note.)                                   Contac-                   (See
tor                                                                                     tor                       note.)

Motor                                                                           PS-3SR  Motor
protection                                                             R                protection
relay                                                                                   relay
                                                                           Stop                                   Waste-  R           PS-3SR
                                                                           Start
                            Water supply               Water           E1                                         water
                                source                   tank      E2
                                                               E3                                                 tank                Start

                                                                                                                                  E1  Stop

            M            P                                                                          M             P       E3 E2

                                                                                                                                                              Reservoir

Note: Be sure to ground the common Electrode E3 (the                                    Note: Be sure to ground the common Electrode E3 (the
        longest Electrode).                                                                     longest Electrode).

Connect terminal 2 to the contactor's coil terminal.                                  Connect terminal 3 to the contactor's coil terminal.

Note: The power supply depends on the specifications of the                             Note: The power supply depends on the specifications of the
         model.                                                                                  model.

With 2-wire connections, only two wires are required between                           With 2-wire connections, only two wires are required between
  the 61F-GP-N8R and Electrode Holder, but three wires are                                the 61F-GP-N8R and Electrode Holder, but three wires are
  required for the Electrodes.                                                            required for the Electrodes.

The Electrode Holder must be specified for 2-wire connections.                         The Electrode Holder must be specified for 2-wire connections.
  (Resistance R is built into Electrode Holders for 2-Wire                                (Resistance R is built into Electrode Holders for 2-Wire
  Connections.)                                                                           Connections.)

Principles of Operation                                                                 Principles of Operation

                 Water                                 (Indicator ON)                               Pump ON                       E1          (Indicator ON)
                 supply
              P                           E1

            Pump OFF

            Pump ON                                    (Indicator OFF)                              Pump OFF                                  (Indicator OFF)
                                                                                                                                                    P
                                E2                                                                                            E2                           Water drainage
                            E3                                                                                            E3

The pump stops when the water level reaches E1 (indicator ON)                           The pump starts when the water level reaches E1 (indicator ON)
and starts when the water level drops below E2 (indicator OFF).                         and stops when the water level drops below E2 (indicator OFF).

                                                                                                                                                                           12
                                                                                61F-GP-N@

Connection with Three-phase Four-line Circuit

When supplying power from N-phase to the Controller in three-phase four-line circuit, refer to the following diagrams.
Line voltage (R-S, S-T, or R-T): 380 or 415 VAC
Phase voltage (N-R, N-S, or N-T): 220 or 240 VAC

61F-GP-N8@, 220 or 240 VAC

                                                               Power source
                                                               380 to 415 VAC

                                                                R S TN*

                                                        6              5                         4         3

                                                  U        Control     24 V
                                                           circuit

                                                           U           8V

                                                                                   Transformer

                                                     7              8              1                2

                                               A

                                                                                               *

                                     Electromagnetic switch

                                                                       Water tank       E1          Stop
                                                  Water supply source                               Start
                                                                                   E2
                                                                                             E3

                                            P
                                     M

Note: Be sure to ground terminal 1.

                                                                                                              13
                                                                               61F-GP-N@

Dimensions

Note: All units are in millimeters unless otherwise indicated.                    Use a PFC-N8 Mounting Bracket to mount the
                                                                                  Level Controller to a PF113A Rail-mounted
61F-GP-N, -NT, -NL, -NH, -ND, -NR, -N -TDL, -N14, -N15, -NH3                      Socket.

49.4                                                            61F-GP-N                                           PFC-N8
                 38                                              PF113A
                                                                                                                                                            4
                                                                61F-GP-N8
                                                                  PF083A   101
                                                                                                                                         Approx. 83
                                                                                                                                             80

                                                        70
                                                           84

                                                                                                                4.5

                                                                               6                                     t = 0.3

                                                                               Note: PFC-N8 Mounting Bracket (provided with
                                                                                       the Level Controller)

61F-GP-N8, -N8L, -N8H, -N8HY, -N8D, -N8R                                       Use a PFC-N8 Mounting Bracket to mount the
                                                                               Level Controller to a PF083A Rail-mounted
                                                                               Socket.

                                                                                                              PFC-N8

                                                                                                                                                       4

49.4                                                                       91     Approx.
                 38
                                                        70                                                      80   83
                                                           84

                                                                                                                4.5

                                                                               6                                     t=0.3

                                                                               Note: PFC-N8 Mounting Bracket (provided with
                                                                                       the Level Controller)

Safety Precautions

Refer to Safety Precautions for All Level Controllers.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                  In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                                               14
                                                       Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                            Application Considerations

SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

       Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

       Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
           safety equipment, and installations subject to separate industry or government regulations.

       Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                       Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

OMRON Corporation                                                                                                                                        2010.3
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                                                   (c)Copyright OMRON Corporation 2010 All Right Reserved.
http://www.ia.omron.com/
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved