Floatless Level Switch (Basic Type)

61F-G@

Basic Building-block Controllers That Mount                                                                       CSM_61F-G__DS_E_4_1
Directly to Panels for Easier Maintenance
                                                                                                                         Position of
Easy maintenance with building-block Relay Units.                                                                      LED indicator
Easy identification of operating status with LED operation

indicator.
Lineup includes models for tropical regions and for high

temperatures. Achieve stable detection even in high-
temperature environments.

          Refer to Safety Precautions for Floatless Level
          Controllers.

Model Number Structure

61F-@@

          12

1. Control Application                                          2. Type

    G: Automatic water supply and drainage                      Blank: General-purpose

    G1: Automatic water supply with idling prevention or water  L 2KM: Long-distance (for 2 km)
          shortage alarm
                                                                L 4KM: Long-distance (for 4 km)
    G2: Automatic water supply and drainage with abnormal
          water increase alarm                                  H: High-sensitivity

    G3: Automatic water supply and drainage with full tank and  D: Low-sensitivity
          water shortage alarm
                                                                R: Two-wire
    G4: Automatic water supply with water level indicator for
          water supply tank and water receiving tank and        T:       High-temperature
          prevention of idling due to water shortage

    I: Liquid level indication and alarm (no two-wire models)

Ordering Information

            Type General-purpose   Long-distance, 2 km           Long-distance, 4 km            High-sensitivity
                                             Model                         Model                       Model
                       Model
                                  61F-GL 2KM                    61F-GL 4KM                  61F-GH
Application G 61F-G               61F-G1L 2KM                   61F-G1L 4KM                 61F-G1H
                                  61F-G2L 2KM                   61F-G2L 4KM                 61F-G2H
Application G1 61F-G1             61F-G3L 2KM                   61F-G3L 4KM                 61F-G3H
                                  61F-G4L 2KM                   61F-G4L 4KM                 61F-G4H
Application G2 61F-G2             61F-IL 2KM                    61F-IL 4KM                  61F-IH
                                  61F-11L 2KM                   61F-11L 4KM                 61F-11H
Application G3 61F-G3

Application G4 61F-G4

Application I 61F-I

Relay Unit    61F-11

            Type Low-sensitivity             2-wire             Tropical environments High-temperature
                                             Model
                       Model      61F-GR                                 Model                       Model
                                  61F-G1R
Application G 61F-GD              61F-G2R                       61F-G-TDL                   61F-GT
                                  61F-G3R
Application G1 61F-G1D            61F-G4R                       61F-G1-TDL                  61F-G1T
                                  ---
Application G2 61F-G2D            61F-11R                       61F-G2-TDL                  61F-G2T

Application G3 61F-G3D                                          61F-G3-TDL                  61F-G3T

Application G4 61F-G4D                                          61F-G4-TDL                  61F-G4T

Application I 61F-ID                                            61F-I-TDL                   61F-IT

Relay Unit    61F-11D                                           ---                         61F-11T

Note: When ordering, specify the desired operating voltage at the end of the model number.
        Example: 61F-G [110/220 VAC]
                                                      Desired supply voltage

                                                                                                                                        1
                                                                                                                        61F-G@

Specifications

Standard Models

Specifications

        Items          General-purpose           High-           Long-distance       High-sensitivity  Low-sensitivity   Two-wire
                           Controller        temperature           Controllers          Controllers       Controller    Controller

                          61F-@ (TDL)         Controller          61F-@L 2KM              61F-@H            61F-@D        61F-@R
                            (see note                               (for 2 km)          (see note 1)     (see note 1)   (see note 1)
                             1 and 2)           61F-@T
                                             (see note 1)         61F-@L 4KM
                                                                    (for 4 km)
                                                                   (see note 1)

Controlling materials  For control of ordi-  For control of ordi- For control of ordi- For control of liq- For control of liq- For control of ordi-
and operating condi-   nary purified water
tions                  or sewage water       nary purified water nary purified water uids with high uids with low spe- nary purified water

                                             or sewage water in cases where the specific resis- cific resistance or sewage water

                                             in cases where the distance between tance such as dis- such as salt water, used in combina-

                                             ambient tempera- sewage pumps tilled water                sewage water, tion with Two-wire

                                             ture is high.     and water tanks or                      acid chemicals, al- Electrode Holder

                                                               between receiver                        kali chemicals (incorporating a

                                                               tanks and supply                                         resistor of 6.8 k)

                                                               tanks is long or                                         It is possible to wire

                                                               where remote                                             with less than one

                                                               control is required.                                     wiring against gen-

                                                                                                                        eral 61F's wiring.

Supply voltage         100, 110, 120, 200, 220 or 240 VAC; 50/60 Hz

Operating voltage range 85% to 110% of rated voltage

InterElectrode voltage 8 VAC                                                         24 VAC            8 VAC

InterElectrode current Approx. 1 mA AC max.

Power consumption 61F-G@: 3.5 VA max.; G1F-G1@, G1F-G2@, or G1F-I@: 5.5 VA max.; G1F-G3@: 7.5 VA max.; G1F-G4@: 14.5 VA max.

InterElectrode operate 0 to approx. 4 k      0 to approx. 5 k  0 to approx.          Approx. 15 k to   0 to approx.     0 to approx. 1.1 k
resistance                                                     1.8 k (for 2 km)      70 k              1.8 k
                                                               0 to approx.          (see note 5)
                                                               0.7 k (for 4 km)

InterElectrode release Approx. 15 k to   Approx. 15 k to       4 k to   (for         Approx. 300 k to Approx. 5 k to   Approx. 15 k to
                                                               2 km)
resistance                                                     2.5 k to   (for                                          
                                                               4 km)

Cable length           1 km max.             600 m max.        2 km max.             50 m max.         1 km max.        800 m max.
(see note 3)                                                   4 km max.

Control output         2 A, 220 VAC (Inductive load: cos = 0.4)
                       5 A, 220 VAC (Resistive load)

Ambient temperature Operating: 10 to 55C (10 to 70C for 61F-@T)

Ambient humidity       Operating: 45% to 85% RH

Insulation resistance 100 M min. (at 500 VDC)
(see note 4)

Dielectric strength    2000 VAC, 50/60 Hz for 1 min.
(see note 4)

Life expectancy        Electrical: 500,000 operations min.
                       Mechanical: 5,000,000 operations min.

Weight                 61F-G@: Approx. 380 g, G1F-G1@, G1F-G2@, or G1F-I@: Approx. 750 g; G1F-G3@: Approx. 930 g;
                       G1F-G4@: Approx. 1,710 g

Note: 1. The @ in the model name represents G, G1, G2, G3, G4, and I.
        2. The suffix "TDL" attached to the model name represents models designed for tropical regions (storage humidity of 45% to 90%). For de-
            tails, refer to Safety Precautions for Floatless Level Controllers.
        3. The length when using completely-insulated, 600-V, 3-conductor (0.75 mm2) cabtire cables. Usable cable lengths will become shorter as
            the cable diameter or number of conductors becomes larger. For details, refer to Safety Precautions for Floatless Level Controllers.
        4. The insulation resistance and dielectric strength indicate values between power terminals and Electrode terminals, between power ter-
            minals and contact terminals, and between Electrode terminals and contact terminals.
        5. Possible to use with 15 k or less, however, this may cause reset failure.
        6. High-sensitivity Controllers use advanced operation.
            When the power supply voltage is applied, if there are some liquids between the electrodes (ground and operation electrodes), the inter-
            nal relay will not operate.
            When the power supply voltage is applied, if there are no liquids between the electrodes (ground and operation electrodes), the internal
            relay will operate.

                                                                                                                                  Advanced Operation

                                                                                                                                  With advanced operation, the internal relay
                                                                                                                                  operates as soon as control power is
                                                                                                                                  supplied to the G1F and is reset when current
                                                                                                                                  flows between the poles. Wiring is the same
                                                                                                                                  as for models with sequential operation.

                                                                                                                                                                                 2
                                                                                                                                                                 61F-G@

Internal Circuit Diagrams

The schematic diagrams shown below typify the internal connections of the various 61F models. The designations Ta, Tb, and Tc (sometimes re-
ferred to collectively as "U") may occur more than once in a product, however, the "a" terminal is always an NO contact, a "b" terminal is an NC
contact, and the "c" terminal is the common terminal.

61F-G                                                 61F-GT                                                      61F-GL

             0V             24 V  61F-11      U                         0V              24 V  61F-11T     U                 0V             24 V  61F-11L     U
                                  Relay Unit                                                  Relay Unit                                         Relay Unit
           100, 110                                                   100, 110                                            100, 110
           or 120 V         8V                                        or 120 V          8V                                or 120 V         8V
           200, 220                                                   200, 220                                            200, 220
           or 240 V                                                   or 240 V                                            or 240 V

                                          U                                                           U                                                  U

                     U                                                          U                                                   U

Ta Tc                       Tb        E2          E1  Ta Tc                             Tb        E2          E1          Ta Tc            Tb        E2          E1

S0                      S1        S2          E3      S0                           S1         S2         E3               S0           S1        S2         E3

61F-GH                                                61F-GD                                                      61F-GR
(See note.)
                                                                         0V                   61F-11D     U                 0V             24 V  61F-11R     U
             0V                                                        100, 110               Relay Unit                                         Relay Unit
                                  61F-11H     U                        or 120 V         24 V                              100, 110
           100, 110         24 V  Relay Unit                           200, 220                                           or 120 V
           or 120 V                                                    or 240 V                                           200, 220
           200, 220                                                                     8V                                or 240 V         8V
           or 240 V
                            24 V

                                                                                                                                                                     U

                                          U                                                           U

                                                                                 U                                                  U

                     U                                                                                                    Ta Tc            Tb                    E1

Ta Tc                       Tb        E2          E1  Ta Tc                             Tb        E2          E1

                                                      S0                            S1        S2          E3              S0           S1        S2          E3

S0                      S1        S2         E3

                                                                                                                                                                         3
                                                                                                                               61F-G@

Note: The 61F11H relay deenergizes when there is water present across the Electrodes, whereas the 61F relay energizes when there is water
        present across the Electrodes.
        Also, the terminal connections of those Controllers provided with LED indicators differ from those which have no indicators.

61F-11 Relay Units

             Item                     61F-11        61F-11T            61F-11L            61F-11H           61F-11D            61F-11R
                                              Provided           Provided           Not provided      Provided           Not provided
Interchangeable with ---
general-purpose mod-                          Red                Yellow             Blue              Black              Green
el (61F-11)

Color of band on name ---
plate

61F-11                                        61F-11T                               61F-11L        E SS              S

        E SS               S                           E SS              S

        8      76          5       4                   8     76          5     4                   8     76           5     4

           8 V 24 V 24 V                                  8 V 24 V 24 V                               8 V 24 V 24 V

               Tr1 Tr2          X                            Tr1 Tr2        X                                Tr1 Tr2     X

            x                   x                         x                 x                         x                  x

9 10 11 1                  2       3          9 10 11 1                  2     3             9 10 11         1        2     3

Tb2 Ta2 Tc2 Tc1 Ta1                Tb1        Tb2 Ta2 Tc2 Tc1 Ta1              Tb1           Tb2 Ta2 Tc2 Tc1 Ta1            Tb1

61F-11H                            Tr2        61F-11D                               61F-11R

(see note)

        E SS               S                           E SS              S                         E SS              S

        8      76          5       4                   8     76          5     4                   8     76          5      4

           24 V 24 V 24 V                                 8 V 24 V 24 V                               8 V 24 V 24 V

               Tr1 Tr2          X                            Tr1 Tr2        X                                Tr1 Tr2     X

            x                   x                         x                 x                         x                  x

9 10 11 1                  2       3          9 10 11 1                  2     3             9 10 11 1                2     3

Ta2 Tb2 Tc2 Tc1            Tb1     Ta1        Tb2 Ta2 Tc2 Tc1 Ta1              Tb1           Tb2 Ta2 Tc2 Tc1 Ta1            Tb1

                                                                                                                                           4
                                                                                                                                                  61F-G@

Connections                                                                                                               Basic Type

Automatic Water Supply and                                                                                                 61F-G
Drainage Control
                                                                                                                              Dimensions:
                                                                                                                              page 13

               Automatic Water Supply Control                                                           Automatic Drainage Control

Connections                                                                              Connections

  220-VAC power supply     61F-G               24 V    61F-11     U                       220-VAC Power supply  61F-G                      24 V     61F-11    U
            RST                            0V        Relay Unit                                      RST                       0V                 Relay Unit

MCCB                                   110 V   8V U                                      MCCB                               110 V          8V U
                                       220 V                                                                                220 V

                                       U                                                                                              U

                           Ta Tc Tb E2 E1                                                                                  Ta Tc Tb E2 E1
                              S0 S1 S2 E3                                                                                     S0 S1 S2 E3

                                                                                 (See
                                                                                 note.)

Contactor                                                            PS-3S               Contactor      (See note.)

Motor                      Water supply              Water                   E1  Stop    Motor                  PS-3S
protection                     source                  tank                      Start   protection
relay                                                             E3 E2                  relay                                             Start

                                                                                                                Waste                  E1

            M           P                                                                            M              water  E3 E2           Stop
                                                                                                                P tank

                                                                                                                                                  Reservoir

Note: Be sure to ground the common Electrode (the longest Electrode).                    Note: Be sure to ground the common Electrode (the longest Electrode).

Connect Tb to the contactor's coil terminal.                                           Connect Ta to the contactor's coil terminal. (Do not connect Tb.)
Power Supply Connections (for models with 110/220-V power)                              Power Supply Connections (for models with 110/220-V power)

  110 VAC: Connect S0 and S1.                                                              110 VAC: Connect S0 and S1.
  220 VAC: Connect S0 and S2.                                                              220 VAC: Connect S0 and S2.

Principles of Operation                                     Relay Unit Location          Principles of Operation                                       Relay Unit Location

               Water                                                     U1                                                                                          U1
               supply
                                               (U indicator ON)                                                                            (U indicator ON)
            P                                                     Powe r
                                                                     supply
                                                                                                                                                                                                                                                                                                                                     Power
                                                                                                                                                                                                                                                                                                                                        supply
                                                                                                                Water tank

            Pump OFF               E1                                                                Pump ON                       E1

            Pump ON                                                                                  Pump OFF

                               E2              (U indicator OFF)                                                                           (U indicator OFF)
                           E3                                                                                                                         P
                                                                                                                               E2
                                                                                                                           E3                       Water drainage

The pump stops (indicator ON) when the water level reaches E1                            The pump starts (indicator ON) when the water level reaches E1
and starts (indicator OFF) when the water level drops below E2.                          and stops (indicator OFF) when the water level drops below E2.

                                                                                                                                                                                                                                                                                                                                                5
                                                                                                                                                                           61F-G@

Automatic Water Supply Control with                                                                                                 Basic Type
Pump Idling Prevention and Automatic
Water Supply Control with Abnormal                                                                                                  61F-G1
Water Shortage Alarm
                                                                                                                                        Dimensions:
                                                                                                                                        page 13

Automatic Water Supply Control with Pump Idling Prevention                                     Automatic Water Supply Control with Abnormal Water Shortage Alarm

Connections                                                                                    Connections

                             61F-G1                                                                                         61F-G1
220 VAC power supply                                                                           220 VAC power supply

            RST                 0V           24 V    61F-11    U1                                          RST                0V                     61F-11    U1
                                                   Relay Unit                                                                                      Relay Unit
                                                                                                                                    24 V

MCCB                     110 V               24 V    61F-11    U2                                                            110 V  24 V             61F-11    U2
                         220 V                     Relay Unit                                                                220 V                 Relay Unit
                                                                                               MCCB

                                             8V                        U1                                                           8V                                 U1
                                                                   U1                                                                                              U1
                                                           U2                                                                                    U2
                                                U2                                                                                     U2

                         So                  Tb1 Ta1               Tc2 Tb2                                                So        Tb1 Ta1                        Tc2 Tb2

                               S1 S2 E3 E2 E1 E2' E1' (E4)                                                                    S1 S2 E3 E2 E1 E2' E1' (E4)

                                                                            B          Push                                                                                 B Push
                                                                                       button
                                                                           Alarm       switch                                                                                         button
                                                                                                                                                                           Alarm switch

                                                                                                                              (See note.)

Contactor                (See note.)                                                           Contactor

Motor                                                          PS-3S                           Motor                                                           PS-4S
protection                                                                                     protection
relay                    PS-3S                                   Water             E1  Stop    relay                          Water supply                     Water               E1                                                                                                                                                                   Stop
                                                                  tank     E3 E2       Start                                      source                         tank         E2                                                                                                                                                                        Start
                        Water                                                                                                                                          E3 E4                                                                                                                                                                            Water

                        supply              E1'                                                                                                                                                                                                                                                                                                         shortage
                        source       E3' E2'
               M                                                                                           M              P
                         P

Note: Be sure to ground the common Electrode (the longest Electrode).                          Note: Be sure to ground the common Electrode (the longest Electrode).

Power Supply Connections                                                                      Power Supply Connections
  110 VAC: Connect S0 and S1.                                                                    110 VAC: Connect S0 and S1.
  220 VAC: Connect S0 and S2.                                                                    220 VAC: Connect S0 and S2.

Insert a pushbutton switch (NO) between E1' and E3, as shown by                               Insert a pushbutton switch (NO) between E3 and E4.
  the dotted lines above.                                                                      If the pump stops when the pushbutton switch is released, press

Do not press the pushbutton if the low-water alarm sounds and                                  it again.
  the pump stops during normal operation (U1 indicator ON, water
  below E2').                                                                                   Test Operation/Recovering from Power Interruptions

Test Operation/Recovering from Power Interruptions                                            If the supply water level is below E4 when starting operation or
                                                                                               when recovering from a power interruption, press the pushbutton
If the supply water level is below E1' when starting operation or                              to momentarily close the circuit (U1 indicator turns ON) to start the
when recovering from a power interruption, press the pushbutton to                             pump.
momentarily close the circuit (U1 indicator turns ON) to start the
pump.

Principles of Operation                                                 Relay Unit Location    Principles of Operation                                                 Relay Unit Location

                                 Water supply source                                                                                Water tank

                                                                                                                  Water
                                                                                                                  supply

                                                                                                           P
                                                                           Power
                                                                              supply
                                                                                                                                                                                                                                                                                                                                            Power
                                                                                                                                                                                                                                                                                                                                                supply
                                                                                       U1 U2                                                                                                                                                                                                                                                            U1 U2

                                       E1'            (U1 indicator ON)                                    Pump OFF                            E1    (U2 indicator ON)
                                                      (U1 indicator OFF)
                         Water E2'                                                                         Pump ON
                         shor-                        (U2 indicator ON)                                                                    E2
                         tage

                               E3

                         BL                                                                                                                          (U2 indicator OFF)
                                                                                                                                                     (U1 indicator OFF)
                 Water               Water tank

                 supply                                                                                    BL             Water E4
                                                                                                                          shor-
            P                                                                                                             tage E3

               Pump OFF                      E1

               Pump ON                                (U2 indicator OFF)
                                         E2

                                           E3                                                   The pump stops (U2 indicator ON) when the water level reaches E1 and
                                                                                                 starts (U2 indicator OFF) when the water level drops below E2.
The pump starts (U2 indicator OFF) when the water level drops below E2
  and stops (U2 indicator ON) when the water level reaches E1.                                  If the water level drops below E4 for any reason, the pump stops (U1
                                                                                                 indicator OFF) and the alarm sounds.
When the level of the water supply source drops below E2', the pump
  stops (U1 indicator OFF). Pump idling is prevented and the alarm sounds.

                                                                                                                                                                                                                                                                                                                                                                  6
                                                                                                                                                                                  61F-G@

Automatic Drainage Control and                                                                                                 Basic Type
Water Supply with Abnormal
Water Increase Alarm                                                                                                                 61F-G2

                Automatic Water Supply with Overfull Tank Alarm                                                                               Dimensions:
    Connections                                                                                                                               page 13

                                                                                                              Automatic Drainage Control with Overfull Tank Alarm
                                                                                                       Connections

                               61F-G2                                                                  220 VAC power supply  61F-G2
220 VAC power supply

            RST             0V            24 V    61F-11    U1                                                     RST              0V     24 V              61F-11      U1
                                                Relay Unit                                                                                                 Relay Unit

MCCB                        110 V         24 V    61F-11    U2                                         MCCB                     110 V      24 V              61F-11      U2
                            220 V               Relay Unit                                                                      220 V                      Relay Unit

                                          8V                                                                                               8V
                                                        U2                                                                                               U2

                                          U2                    U1                                                                         U2                                 U1

                         So Ta1 Tc1 Tb1 Ta2 Tc2                                                                              So Ta1 Tc1 Tb1 Ta2 Tc2
                            S1 S2 E3 E2 E1 E4                                                                                   S1 S2 E3 E2 E1 E4

                                                                 B                                                                                                             B

                                                                Alarm                                                                                                         Alarm

                            (See note.)                         PS-4S                                                               (See note.)

Contactor                   Water supply                        Water                       E4  Full   Contactor             Waste                         PS-4S
                                source                            tank                  E1      Stop
Motor                                                                                           Start  Motor
protection                                                                      E3 E2                  protection            water                                Full
relay                                                                                                  relay                                                      Start
                                                                                                                                                                  Stop
                                                                                                                             tank                      E4

            M            P                                                                                         M         P                     E1
                                                                                                                                           E3 E2

                                                                                                                                                                             Reservoir

Note: Be sure to ground the common Electrode (the longest Electrode).                                  Note: Be sure to ground the common Electrode (the longest Electrode).

Connect Tb1 to the power supply.                                                                      Connect Ta1 to the power supply.
Power Supply Connections                                                                              Power Supply Connections

  110 VAC: Connect S0 and S1.                                                                            110 VAC: Connect S0 and S1.
  220 VAC: Connect S0 and S2.                                                                            220 VAC: Connect S0 and S2.

Principles of Operation                                             Relay Unit Location                Principles of Operation                                               Relay Unit Location

                 Water                             Upper L  B                                             BL                               Upper
                 supply                              limit  (U1 indicator ON)                                                              limit
            P                                E4             (U2 indicator ON)   Power                  Pump ON
                                                                                  supply               Pump OFF
               Pump OFF                   E1                                                                                                                                                                                                                                     Power
                                                                                                                                                                                                                                                                                    supply
                                                                                U1 U2                                                  E4                  (U1 indicator ON)                                                                                                                U1 U2
                                                                                                                                    E1                     (U2 indicator ON)

            Pump ON                                         (U2 indicator OFF)                                                  E2                         (U2 indicator OFF)
                                      E2                                                                                     E3                                P

                            E3

                                                                                                                                                           Water drainage

The pump starts (U2 indicator OFF) when the water level                                              The pump starts (U2 indicator OFF) when the water level
  drops below E2 and starts (U2 indicator ON) when the water                                             reaches E1 and stops (U2 indicator ON) when the water level
  level reaches E1.                                                                                      drops below E2.

If the water level reaches E4 for any reason, the alarm sounds                                        If the water level reaches E4 for any reason, the alarm sounds
  (U1 indicator ON).                                                                                     (U1 indicator ON).

                                                                                                                                                                                                                                                                                                   7
                                                                                                                                                                                                                                                                                                     61F-G@

Automatic Water Supply and Drainage                                                                                                  Basic Type
Control with Abnormal Water Increase and
Water Shortage Alarms                                                                                                                61F-G3

                                                                                                                                                Dimensions:
                                                                                                                                                page 13

Automatic Water Supply with Abnormal Water Increase and Water Shortage Alarms                           Automatic Drainage Control with Abnormal Water Increase and Water Shortage Alarms

Connections                                                                                             Connections

                               61F-G3                                                                   220 VAC power supply  61F-G3
220 VAC power supply
                                             24 V         61F-11       U1                                     RST                    0V   24 V     61F-11         U1
              RST                                       Relay Unit                                                                               Relay Unit

                                         0V

                                             24 V         61F-11       U2                                                                 24 V     61F-11         U2
                                                        Relay Unit                                                                               Relay Unit
MCCB              110 V                                                                                 MCCB                  110 V
                                                                                                                              220 V
                                             24 V         61F-11       U3                                                                 24 V     61F-11         U3
                                                        Relay Unit                                                                               Relay Unit
                  220 V

                                                    8V                                                                                    8V

                                                        U1 U3 U1 U3        U2                                                                    U1 U3 U1 U3                                                                                                                                                          U2

                           U2                                                                                                         U2

                  Ta Tc Tb B1 B2 Lc E1 E3 E5                                                                                  Ta Tc Tb B1 B2 Lc E1 E3 E5

                           S0 S1 S2                           LH LL E2 E4                                                            S0 S1 S2                     LH LL E2 E4

                                                              Alarm

                                                                        Upper
                                                                           limit
                                                                                      Lower
                                                                                         limit

                                                                                                                                                                                                                Alarm

                                                                                                                                                                                                                                                                             Upper
                                                                                                                                                                                                                                                                                limit
                                                                                                                                                                                                                                                                                           Lower
                                                                                                                                                                                                                                                                                              limit
                                                        B PL PL                                                                                            B PL PL

Contactor                                                                                    (See       Contactor                                                                                                                                                                                                         (See
                                                                                             note.)     Motor                                                                                                                                                                                                             note.)
Motor                                                                                                   protection
protection                                                                                   Full tank  relay
relay
                                                                                               Stop                    M
                                                        PS-5S                                  Start                                                       PS-5S
                                                                                             Water
                           Water                        Water                            E1  shortage                                                      Full tank
                           supply                       tank                         E2
                           source                                       E5 E4 E3
                                                                                                                              Waste                    E1     Start
            M  P                                                                                                              water                E2         Stop
                                                                                                                              tank    E5 E4 E3
                                                                                                                                                           Water shortage
                                                                                                                              P

                                                                                                                                                                  Reservoir

Note: Be sure to ground the common Electrode (the longest Electrode).                                   Note: Be sure to ground the common Electrode (the longest Electrode).

Connect Tb to the contactor's coil terminal.                                                          Connect Ta to the contactor's coil terminal. (Do not connect
Power Supply Connections                                                                                Tb.)

  110 VAC: Connect S0 and S1.                                                                            Power Supply Connections
  220 VAC: Connect S0 and S2.                                                                             110 VAC: Connect S0 and S1.
                                                                                                          220 VAC: Connect S0 and S2.

Principles of Operation                                                    Relay Unit Locations         Principles of Operation                                            Relay Unit Locations

      Water                                             LH B                        U1 U2 U3                                                         LH B
      supply                                                                                                                              Upper
  P                                          Upper                         Power                                                                                                                                                                                                                                      U1 U2 U3
                                                                              supply
Pump OFF                                     limit                                                                                                                                                                                                                                                         Power
                                                                                                                                                                                                                                                                                                              supply
                                                    (U1 indicator ON)                                                                     limit  (U1 indicator ON)

                               E1                                                                                                     E1

                           E2                       (U2 indicator ON)

                                                                                                        Pump ON                                         (U2 indicator ON)

                                                                                                                                     E2

Pump ON                E3                           (U2 indicator OFF)

                  E4                                (U3 indicator OFF)                                  Pump OFF                                  (U2 indicator OFF)
               E5
                                             Lower      LL B                                                                     E3               (U3 indicator OFF)
                                             limit                                                                                        Lower
                                                                                                                              E4          limit LL B
                                                                                                                          E5

The pump stops (U2 indicator ON) when the water level                                                 The pump starts (U2 indicator ON) when the water level
  reaches E2 and starts (U2 indicator OFF) when the water level                                           reaches E2 and stops (U2 indicator OFF) when the water level
  drops below E3.                                                                                         drops below E3.

If the water level rises to E1 for any reason, the upper-limit                                        If the water level rises to E1 for any reason, the upper-limit
  indicator turns ON and the alarm sounds (U1 indicator ON).                                              indicator turns ON and the alarm sounds (U1 indicator ON).
  If the water level drops below E4 for any reason, the lower-limit                                       If the water level drops below E4 for any reason, the lower-limit
  indicator turns ON and the alarm sounds (U3 indicator OFF).                                             indicator turns ON and the alarm sounds (U3 indicator OFF).

                                                                                                                                                                                                                                                                                                                                  8
                                                                                                                                                                            61F-G@

Automatic Water Supply Control with Water                                                                                           Basic Type
Source Level Indication, Prevention of
Pump Idling Due to Water Shortage, and                                                                                              61F-G4
Indication of Water Level in Tank
                                                                                                                                      Dimensions:
                                                                                                                                      page 13

  Automatic Water Supply Control with Water Source Level Indication, Prevention of Pump Idling Due to Water Shortage, and Indication of Water Level in Tank

Connections

Power Supply Connections                   220 V power supply     61F-G4
  110 VAC: Connect S0 and S1.                        RST
  220 VAC: Connect S0 and S2.                                                                             0V        24 V    61F-11                  U5
                                       MCCB                                                            110 V              Relay Unit
Insert a pushbutton switch (NO)                                                                      220 V
  between E2 and E8, as shown by                                                                                    24 V    61F-11                  U1
  the dotted lines above.                                                                                                 Relay Unit

Do not press the pushbutton if the                                                               0V               24 V    61F-11                  U2
  low-water alarm sounds and the                                                            U2                            Relay Unit
  pump stops during normal                                               MK3P
  operation (water below E3).                                            Relay           X 110 V                    24 V    61F-11                  U3
                                                                         (See                                             Relay Unit
                                                                         note 2.)

                                                                                                                    24 V    61F-11                  U4
                                                                                                                          Relay Unit

Test Operation/Recovering from                                                                        220 V        8V
Power Interruptions
                                                                     U1     X             U4             U3 X U1 U5 X               U4                  U3           U2 U5
If the supply water level is below E2
when starting operation or when                                     LL1 LL2 LH1 LH2 BL1 BL2 BH1 BH2 E4 E3 E2 E1
recovering from a power interruption                                    S0 S1 S2 TC TC2 B TA E8 E7 E6 E5
(U2 indicator OFF), press the
pushbutton to momentarily close the
circuit to start the pump.

                                                                         Elevated Water supply Elevated  Water supply Elevated Water supply Elevated    Water
                                                                                                                                                        supply
                                                                         tank water source lower tank    source upper tank water source lower tank      source
                                                                                                                                                        upper limit
                                                                         shortage limit   repletion      limit      shortage limit  repletion

                                                                    LL1 LL2 LH1 LH2 BL1 BL2 BH1 BH2                                                                                              Push-
                                                                                                                                                                                                 button
                                      Contactor                                                                                                                                                  switch

                                                      (See note 1.)                                                                                                                       PS-5S

                                          Motor                  Water                    PS-4S                                                             Water                     E4  Full tank
                                      protection                                                                                                            tank                  E5
                                                                 supply                                Upper limit                                                                        Stop
                                            relay                                                                                                                            E6           Start
                                                                                                                                                                                          Water
                                                                 source               E1               Start                                                         E8 E7                shortage
                                                                                   E2
                                                                                                       Stop
                                                   M             P          E8 E3                      Lower limit

                                                   Note: Be sure to ground the common Electrode (the longest Electrode).

Principles of Operation

Insert four Electrodes in the water supply source and five Electrodes in the elevated water tank.                                                                  Relay Unit Location

The lower-limit indicator for the water supply source remains ON while the water source level is below E3 (U2 indicator                                                U1 U2 U3 U4
  OFF).                                                                                                                                                                  U Power
                                                                                                                                                                           5 supply
When the water level rises to E2, the lower-limit indicator turns OFF (U2 indicator ON) and the pump is ready for
  operation.

The upper-limit indicator in the water supply source lights when the water level reaches E1 (U3 indicator ON).

The water-shortage indicator for the elevated tank remains ON while the water level in the elevated tank is below E7.
  The indicator turns OFF (U1 indicator ON) when the water level rises to E7.

The pump stops (U5 indicator ON) when the water level reaches E5 and starts (U5 indicator OFF) when the water level
  drops below E6.

If the water level reaches E4 for any reason, the abnormal water increase indicator for the elevated tank turns ON (U4
  indicator ON).

                                                                                                                                                                                                         9
                                                                                                                        61F-G@

Connection with Three-phase Four-line Circuit

When supplying power from N-phase to the Controller in three-phase four-line circuit, refer to the following diagrams.
Line voltage (R-S, S-T, or R-T): 380 or 415 VAC
Phase voltage (N-R, N-S, or N-T): 220 or 240 VAC

61F-G@, 220 or 240 VAC

Water Supply

              Power source                                 Transformer
              380 or 415 VAC

                R S TN*

                                                               24 V         61F-11      U
                                                                            Relay Unit

                                                               8V

                                                       Ta                   Tc      Tb            E2         E1

                                                           S0                   S1         S2         S3

                                                                                                               *

                                                       Rated voltage:

                                                    A  S0-S2: 220 or 240 VAC

              Electromagnetic switch                           Water tank

                                                                                              E1      Stop
                                                                                                      Start
                                                                                    E2
                                                       Water supply source               E3

                     P
              M

              Note: Be sure to ground terminal E3.

                                                                                                                                10
                                                                                                                                              61F-G@

Liquid Level Indication and Alarm                                                                         Basic Type

                                                                                                          61F-I

                                                                                                             Dimensions:
                                                                                                             page 13

                                             Liquid Level Indication and Alarm

Connections

Power Supply Connections
  110 VAC: Connect S0 and S1.
  220 VAC: Connect S0 and S2.

                                       220-VAC power supply  61F-I
                                                RST                    0V

                                                                                24 V     61F-11    U1
                                                                                       Relay Unit

                                       MCCB                         110 V       24 V     61F-11    U2
                                                                    220 V              Relay Unit

                                                                                8V

                                                                         U2     U1     U1          U2

                                                                    TC B L3 L2 L1
                                                                        S0 S1 S2 E3 E2 E1

                                                                              Alarm Intermediate Upper limit Lower limit               PS-3S

                                                                             B PL PL PL (See note.)

                                                                         Water supply                         Water                E1  Upper alarm
                                                                             source                           tank        E3 E2           Intermediate

                                                                                                                                       Lower alarm

                                             M               P

                                       Note: Be sure to ground the common Electrode (the longest Electrode).

Principles of Operation                                             Water tank                                                         Relay Unit Location

When the water level drops below           B LH Upper                               (U1 indicator ON)                                          U1 U2Power
  E2, the lower-limit indicator turns                                                 (U1 indicator OFF)                                        supply
  ON and the alarm sounds (U2
  indicator OFF).                                            limit       E1           (U2 indicator ON)
                                                                                      (U2 indicator OFF)
When the water level reaches E2,              LM Middle
  the alarm turns OFF and the
  intermediate indicator turns ON            B LL            Lower E2
  (U2 indicator ON).                                         limit

When the water level rises to E1,                                  E3
  the upper-limit indicator turns ON
  and the alarm sounds (U1
  indicator ON).

                                                                                                                                                            11
Two-Wire Connections                                                                                                                  61F-G@

Automatic Water Supply and                                                                                                Basic Type
Drainage Control
                                                                                                                          61F-GR

                    Automatic Water Supply Control                                                        Automatic Drainage Control
Connections                                                                        Connections

220-VAC power supply     61F-GR                24 V  61F-11R      U                220-VAC power supply          61F-GR                 24 V  61F-11R     U
            RST                         0V           Relay Unit                                RST                              0V            Relay Unit

MCCB                                 110 V                                         MCCB                                      110 V
                                     220 V                                                                                   220 V
                                               8V                                                                                       8V
                                                                        U                                                                                        U

                                                    U      E1                                                                     U               E1
                                                       E3                                                                                     E3
                                   Ta Tc Tb                                                                      Ta Tc Tb
                                       S0 S1 S2                                                                      S0 S1 S2

                                                                           (See                          (See
                                                                           note.)                        note.)

Contactor                                      PS-3SR                              Contactor                                 PS-3SR
                                                              R
Motor                                                                              Motor
protective               Water supply          Water           E1          Stop    protective                          R
relay                        source            tank    E2 E3               Start   relay                 Waste

                                                                                                         water           E1      Start
                                                                                                                 E2 E3
                                                                                                         tank                    Stop
                                                                                                          P
            M         P                                                                        M

                                                                                                                                              Reservoir

Note: Be sure to ground the common Electrode (the longest Electrode).              Note: Be sure to ground the common Electrode (the longest Electrode).

Connect Tb to the contactor's coil terminal.                                     Connect Ta to the contactor's coil terminal. (Do not connect Tb.)
                                                                                    Power Supply Connections (for models with 110/220-V power)
Power Supply Connections
  110 VAC: Connect S0 and S1.                                                        110 VAC: Connect S0 and S1.
  220 VAC: Connect S0 and S2.                                                        220 VAC: Connect S0 and S2.
                                                                                    With 2-wire connections, only two wires are required between
With 2-wire connections, only two wires are required between                       the 61F-GR and Electrode Holder, but three wires are required
  the 61F-GR and Electrode Holder, but three wires are required                      for the Electrodes.
  for the Electrodes.                                                               The Electrode Holder must be specified for 2-wire connections.
                                                                                     (Resistance R is built into Electrode Holders for 2-Wire
The Electrode Holder must be specified for 2-wire connections.                     Connections.)
  (Resistance R is built into Electrode Holders for 2-Wire                         The Relay Unit must also be specified for 2-wire connections.
  Connections.)
                                                                                   Principles of Operation
The Relay Unit must also be specified for 2-wire connections.

Principles of Operation

                           Water
                           supply
                        P

                                               (U indicator ON)                                Pump ON                       E1         (U indicator ON)

            Pump OFF                       E1

            Pump ON                                                                            Pump OFF                                 (U indicator OFF)
                                                                                                                                             P
                                       E2      (U indicator OFF)                                                     E2                      Water drainage
                                   E3                                                                            E3

The pump stops (U indicator ON) when the water level reaches E1                    The pump starts (U indicator ON) when the water level reaches
and starts (U indicator OFF) when the water level drops below E2.                  E1 and stops (U indicator OFF) when the water level drops below
                                                                                   E2.

                                                                                                                                                                    12
                                                                                                                        61F-G@

Dimensions

Note: All units are in millimeters unless otherwise indicated.

Standard Models

61F-G

                                                                M3 screw  Mounting Holes

                                                                                      Four, 6-dia mounting holes

                           Four, 6-dia holes

61F-G1                                                          M3 screw  Mounting Holes
61F-G2
61F-I                                                                          Four, 6-dia mounting holes

        Four, 6-dia holes

61F-G3                                                          M3 screw  Mounting Holes

        Four, 6-dia holes                                                     Four, 6-dia mounting holes

61F-G4                                                                    Mounting Holes

                                                                M3 screw    Four, 6-dia mounting holes

                      Four, 6-dia holes

        ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
        To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                          In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                        13
                                                       Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                            Application Considerations

SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

       Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

       Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
           safety equipment, and installations subject to separate industry or government regulations.

       Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                       Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

OMRON Corporation                                                                                                                                        2010.4
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                                                   (c)Copyright OMRON Corporation 2010 All Right Reserved.
http://www.ia.omron.com/
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191