电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

61F-1P-AC220

器件型号:61F-1P-AC220
器件类别:热门应用    机电/工控/自动化   
文件大小:6197.5KB,共8页
厂商名称:All Sensors
下载文档

器件描述

控制器 level control

参数
制造商: Omron
产品种类: 控制器
RoHS:

61F-1P-AC220器件文档内容

Floatless Level Switch (Plug-in Type)                                                         CSM_61F-G_P_DS_E_3_1

61F-G@P

Compact, Space-saving Plug-in Type Ideal
for Pump Panels or Building into Equipment.

Large switching capacity: 5 A at 220 VAC (resistive load).
Easy to handle with DIN rail mounting.
Replace for maintenance without rewiring the socket.

Refer to Safety Precautions for Floatless Level
Controllers.

Model Number Legend

61F-@P@

          12

1. Control Applications                            2. Type

G1: Automatic water supply with idling prevention  Blank: General-purpose
     or water shortage alarm                       L 2KM: Long-distance (for 2 km)
                                                   L 4KM: Long-distance (for 4 km)
G2: Automatic water supply and drainage with       H: High-sensitivity
     abnormal water increase alarm                 D: Low-sensitivity

I: Liquid level indication and alarm

Ordering Information

Type          General-purpose           Long-distance (for 2 km)     Long-distance (for 4 km)
                                                     Model                        Model
                    Model
                                     61F-G1PL 2K                  61F-G1PL 4KM
G1 models 61F-G1P

Type          High-sensitivity                Low-sensitivity
                                                     Model
                    Model
                                     61F-G1PD
G1 models 61F-G1PH

Type          General-purpose           Long-distance (for 2 km)     Long-distance (for 4 km)
                                                     Model                        Model
                    Model
                                     61F-G2PL 2KM                 61F-G2PL 4KM
G2 models 61F-G2P

Type          High-sensitivity                Low-sensitivity
                                                     Model
                    Model
                                     61F-G2PD
G2 models 61F-G2PH

    Type          General-purpose       Long-distance (for 2 km)     Long-distance (for 4 km)
I models                  Model                      Model                        Model

          61F-IP                     61F-IPL 2KM                  61F-IPL 4KM

    Type           High-sensitivity           Low-sensitivity
I models                  Model                      Model

          61F-IPH                    61F-IPD

Note: When ordering, specify the desired operating voltage at the end of the model number.
        Example: 61F-G1P [110VAC]
                                                      Desired supply voltage

                                                                                                                     1
                                                                                                                   61F-G@P

Plug-in Models

Specifications

        Item           General-purpose                   Long-distance        High-sensitivity                     Low-sensitivity
                           Controller                      Controllers           Controllers                          Controller

                              61F-G1P                      61F-G1PL                    61F-G1PH                               61F-G1PD
                              61F-G2P                      61F-G2PL                    61F-G2PH                               61F-G2PD

                               61F-IP                       61F-IPL                      61F-IPH                                61F-IPD
                                                          (see note 2)        (see note 1, see note 6)             For control of liquids with
                                                                                                                   low specific resistance such
Controlling materials and For control of ordinary puri- For control of ordinary puri- For control of liquids with  as salt water, sewage water,
                                                                                                                   acid chemicals, alkali chem-
operating conditions   fied water or sewage water fied water in cases where high specific resistance               icals

                                                 the distance between sew- such as distilled water                 8 VAC
                                                                                                                   Approx. 1.2 mA AC max.
                                                 age pumps and water tanks
                                                                                                                   0 to approx. 1.8 k
                                                 or between receiver tanks
                                                                                                                   Approx. 5 k to  
                                                 and supply tanks is long or
                                                                                                                   1 km max.
                                                 where remote control is re-

                                                 quired.

Supply voltage         100, 110, 200, 220 VAC; 50/60 Hz

Operating voltage range 85% to 110% of rated voltage

Interelectrode voltage 8 VAC                                                  24 VAC

Interelectrode current Approx. 1 mA AC max.                                   Approx.
                                                                              0.4 mA AC max.

Power consumption      Approx. 6.4 VA max.

Interelectrode operate re- 0 to approx. 4 k      0 to 1.8 k (for 2 km)        Approx. 15 k to
sistance                                         0 to 0.7 k (for 4 km)        approx. 70 k
                                                                              (see note 5)

Interelectrode release re- Approx. 15 k to       4 k to   (for 2 km)          Approx. 300 k to  
sistance                                         2.5 k to   (for 4 km)

Response time          Operate: 80 ms max.
                       Release: 160 ms max.

Cable length           1 km max.                 2 km max.                    50 m max.
(see note 3)                                     4 km max.

Control output         2 A, 200 VAC (Inductive load: cos = 0.4)
                       5 A, 200 VAC (Resistive load)

Ambient temperature    Operating: 10 to 55C

Ambient humidity       Operating: 45% to 85% RH

Insulation resistance  100 M min. (at 500 VDC)
(see note 4)

Dielectric strength    2000 VAC, 50/60 Hz for 1 min.
(see note 4)

Life expectancy        Electrical: 500,000 operations min.
                       Mechanical: 5,000,000 operations min.

Weight                 Approx. 495 g

Note: 1. The relay in the 61F-G1H/-G2H/-IPH de-energizes when there is water present across the Electrodes, whereas the relay in the 61F-GP-
            N8HY energizes when there is water present across the Electrodes.

        2. Models are available for 2 km and 4 km.

        3. The length when using completely-insulated, 600-V, 3-conductor (0.75 mm2) cabtire cables. Usable cable lengths will become shorter as
            the cable diameter or number of conductors becomes larger. For details, refer to Safety Precautions for Floatless Level Controllers.

        4. The insulation resistance and dielectric strength indicate values between power terminals and Electrode terminals, between power
            terminals and contact terminals, and between Electrode terminals and contact terminals. For details, refer to Safety Precautions for
            Floatless Level Controllers.

        5. Possible to use with 15 k or less, however, this may cause reset failure.

        6. High-sensitivity Controllers use advanced operation.
            When the power supply voltage is applied, if there are some liquids between the electrodes (ground and operation electrodes), the inter-
            nal relay will not operate.
            When the power supply voltage is applied, if there are no liquids between the electrodes (ground and operation electrodes), the internal
            relay will operate.

                                                                                                                                                      2
                                                                                                                                                                61F-G@P

Internal Circuit Diagrams

61F-G1P/-G1PL/-G1PD                                         61F-G1PH                                                61F-G2P/-G2PL/-G2PD

    77 1144 66 55 1122                         44 33                7 14 6         5                12 4         3  U2 7       14        6  5 12 4                  3
                                                  U1
        U2                                                                                                U1
                24 V Control circuit U1                                U2                                                                                   U1

                                                                           24 V Control circuit U1                                 24 V Control circuit U1

    Power      24 V Control circuit U2                         Power       24 V Control circuit U2                     Power       24 V Control circuit U2
    supply                                                     supply                                                  supply

                   8V                                                      24 V                                                    8V

                                U2             U1                                      U2           U1

88  99         1155 1100 11         1111 22                 8       9      15 10 1 11 2                             8  9           15    10 U2 1            11  2

61F-G2PH                                                    61F-IP/-IPL/-IPD                                        61F-IPH

U2 7           14      6  5 12 4                      3        7 14 6              5 12 4                     3        7 14 6               5 12 4                  3

                                           U1                          U2          U1                                          U2           U1
               24 V Control circuit U1
                                                                               U2                   U1                                 U2                       U1
               24 V Control circuit U2
    Power      8V                                                          24 V Control circuit U1                                 24 V Control circuit U1
    supply
                                                            Power                                                      Power
                                                            supply         24 V Control circuit U2                     supply      24 V Control circuit U2

                                                                           8V                                                      24 V

8           9  15      10 U2 1      11             2     8     9 15 10 1 11 2                                       8  9 15 10 1 11 2

Note: The 61F-G@PH High-sensitivity Controller uses advanced operation. The internal relay will operate on the NO contact side when power is
        supplied and then will operate according to the liquid level.

                                                                                                                                                                         3
Connections                                                                                                                                                     61F-G@P

Automatic Water Supply Control with Pump                                                                                                           Plug-in Type
Idling Prevention and Abnormal Water
Shortage Alarm                                                                                                                                     61F-G1P

                                                                                                                                                      Dimensions:
                                                                                                                                                      Page 7

Automatic Water Supply Control with Pump Idling Prevention                                                 Automatic Water Supply Control with Abnormal Water Shortage Alarm

Connections                                    B Alarm                                                     Connections                                                 B Alarm

Commercial Voltage          61F-G1P                                                                        Commercial Voltage     61F-G1P
              RST                                                                                                         RST

MCCB                                       7 14 6 5 12 4 3                                                   MCCB                                  7 14 6 5 12 4 3

                                                                                   U1                                                                                                          U1
                                               U2                                                                                                          U2

                                           0V          24 V  Control   U1                                                                          0V          24 V    Control   U1
                                                              circuit                                                                                                   circuit

                                                       24 V  Control   U2                                                                                      24 V    Control   U2
                                                              circuit                                                                                                   circuit

                                       Power    8V                     U2          U1                                                   Power               8V                   U2     U1
                                       supply                                                                                           supply
                                               15 10            1 11 2                                                                                     15 10       1 11 2
                                    89                                                                                               89

                                                                                                                                                                                        Pushbutton switch

                                                                                       Pushbutton
                                                                                          switch

Contactor                   (See note.)                                    PS-3S                           Contac-                                 (See note.)
                                                                                                           tor                                                PS-4S
Motor
protection                          PS-3S                                  Water               E1          Motor                  Water supply                 Water                E1
relay                                                                        tank      E3 E2               protection             source                         tank          E2
                            Water                                                                          relay                                                       E3 E4

                        M   supply                E1'                                                                  M          P
                            source         E3 E2'

                             P

Note: Be sure to ground the common Electrode E3 (the                                                       Note: Be sure to ground the common Electrode E3 (the
        longest Electrode).                                                                                        longest Electrode).
                                                                                                                   Connection Sockets
Insert a pushbutton switch between terminals 11 and 15 as                                                        14PFA (Front-connecting)
  shown by the dotted lines.                                                                                       PL15 (Rear-connecting)

Do not press the pushbutton if the low-water alarm sounds and                                             Insert a pushbutton switch between terminals 11 and 15 as
  the pump stops during normal operation (water below E2').                                                  shown by the dotted lines.

Test Operation/Recovering from Power Interruptions                                                         If the pump stops when the pushbutton switch is released,
                                                                                                             press it again.
If the supply water level is below E1' when starting operation or
when recovering from a power interruption, press the pushbutton                                             Test Operation/Recovering from Power Interruptions
to momentarily close the circuit to start the pump.
                                                                                                           If the supply water level is below E4 when starting operation or
                                                                                                           when recovering from a power interruption, press the pushbutton
                                                                                                           to momentarily close the circuit to start the pump.

Principles of Operation                                                                                    Principles of Operation

            Water supply source                                     Water tank                                                                     Water tank
                                                        Water
                                                        supply                                                            Water
                                                                                                                          supply
                                                             P                         (U2 indicator ON)               P
                                                                                       (U2 indicator OFF)
                                                        Pump            E1                                             Pump OFF                            E1          (U2 indicator ON)
                                                         OFF                                                                                                           (U2 indicator OFF)
              Water            E1'  (U1 indicator ON)               E2                                                 Pump ON                         E2              (U1 indicator OFF)
              shortage      E2'     (U1 indicator OFF)  Pump    E3                                                                                 E4
                                                          ON                                                                             Water
BL                                                                                                                                       shortage

                        E3                                                                                               BL

The pump starts when the water level in the tank drops below                                                                                     E3
  E2 and stops when the water level reaches E1.
                                                                                                            The pump stops when the water level reaches E1 and starts
When the level of water supply source drops below E2', the                                                 when the water level in the tank drops below E2.
  pump stops. Pumping idling is prevented and the alarm
  sounds.                                                                                                   If the water level drops below E4 for any reason, the pump
                                                                                                             stops and the alarm sounds.

                                                                                                                                                                                                           4
                                                                                                                                                   61F-G@P

Automatic Water Supply and Drainage                                                                                   Plug-in Type
Control with Abnormal Water Increase
Alarm                                                                                                                 61F-G2P

                                                                                                                         Dimensions:
                                                                                                                         Page 7

Automatic Water Supply with Abnormal Water Increase Alarm                         Automatic Drainage Control with Abnormal Water Increase Alarm

Connections                                   B Alarm                             Connections                                 B Alarm

Commercial Voltage   61F-G2P                                                     Commercial Voltage  61F-G2P
                 RST                                                                             RST

MCCB                           7 14 6 5 12 4 3                                    MCCB                                7 14 6 5 12 4 3

                         U2             24 V  Control      U1                                            U2                   24 V   Control      U1
                          0V                   circuit  U1                                                0V                          circuit  U1

                                        24 V  Control   U2                                                                    24 V   Control   U2
                                               circuit                                                                                circuit

                         Power          8V                                                               Power                8V

                         supply                         U2                                               supply                                U2

                         8 9 15 10 1 11 2                                                                8 9 15 10 1 11 2

Contac-                  (See note.)                                              Contac-
tor                                                                               tor
                                                            PS-4S                                     (See note.)
Motor                                                                             Motor
protection               Water supply source                Water          E1 E4  protection                                            PS-4S
relay                                                         tank  E3 E2         relay

                                                                                                         Wastewater

            M         P                                                                       M       P               tank E3 E2 E1 E4

                                                                                                                                                      Reservoir

Note: Be sure to ground the common Electrode E3 (the                              Note: Be sure to ground the common Electrode E3 (the
        longest Electrode).                                                               longest Electrode).

        Connection Sockets                                                                Connection Sockets
        14PFA (Front-connecting)                                                          14PFA (Front-connecting)
        PL15 (Rear-connecting)                                                            PL15 (Rear-connecting)

Connect terminal 14 to power supply terminal 9. (Terminal 8 is                   Connect terminal 8 to power supply terminal 9.
  not connected.)

The power supply depends on the specifications of the model.

                Water               E4             LB                             Principles of Operation                        E4           BL
                supply           E1     Upper                                                                                 E1
            P                           limit (U1 indicator ON)                                              Pump ON                 Upper

            Pump OFF                            (U2 indicator ON)                                                                    limit (U1 indicator ON)

                                                                                                                                             (U2 indicator ON)

            Pump ON                           (U2 indicator OFF)                              Pump OFF                                  (U2 indicator OFF)
                                                                                                                                              P
                             E2                                                                                           E2                         Water drainage
                         E3                                                                                           E3

The pump starts when the water level drops below E2 and                         The pump starts when the water level reaches E1 and stops
  stops when the water level reaches E1.                                            when the water level drops below E2.

If the water level drops below E4 for any reason, the pump                      If the water level drops below E4 for any reason, the pump
  stops and the alarm sounds.                                                       stops and the alarm sounds.

                                                                                                                                                                     5
                                                                                                                                                    61F-G@P

Liquid Level Indication and Alarm                                                                                               Plug-in Type

                                                                                                                                61F-IP

                                                                                                                                   Dimensions:
                                                                                                                                   Page 7

                                         Liquid Level Indication and Alarm

Connections

             Commercial Voltage
                    RST

             MCCB

                                                                     Alarm

                                                                                    Upper limit
                                                                                                    Intermediate
                                                                                                                   Upper limit
                                                 B PL PL PL

                                 61F-IP

                                         7 14 6 5 12 4 3

                                                 U2                            U1              U1

                                                                     U2

                                         0V          24 V            Control   U1
                                                                      circuit

                                                     24 V            Control   U2
                                                                      circuit

                                         Power       8V

                                         supply

                                         8 9 15 10 1 11 2

                                                    (See note.)                                                                              PS-3S

                                         Water supply                                             Water                                  E1         Upper alarm
                                             source                                               tank                              E2              Intermediate
                                                                                                                                E3                  Lower alarm

                   M             P

             Note: Be sure to ground the common Electrode E3 (the longest Electrode).

                     Connection Sockets
                     14PFA (Front-connecting)
                     PL15 (Rear-connecting)

Principles of Operation                                                               Water tank

When the water level drops E2, the lower-limit indicator turns ON  B LH Upper                                                 (U1 indicator ON)
  and the alarm sounds.                                                                                                         (U1 indicator OFF)
                                                                               limit       E1
When the water level reaches E2, the indicator turns OFF and                                                                  (U2 indicator ON)
  the intermediate indicator turns ON.                                   LM Middle                                              (U2 indicator OFF)

When the water level rises to E1, the upper-limit indicator turns
  ON and the alarm sounds.

                                                                     B LL      Lower E2
                                                                               limit

                                                                                       E3

                                                                                                                                                                  6
                                                                              61F-G@P

Dimensions

Note: All units are in millimeters unless otherwise indicated.

61F-G1P, -G1PL, -G1PH, -G1PD
61F-G2P, -G2PL, -G2PH, -G2PD
61F-IP, -IPL, -IPH, -IPD

79 60                                                                 61F-G1P

                                                                      61F-G2P

                                                                      61F-IP   118

                                                        3.5     89
                                                        30
                                                                97.5

                                                        72

                                                                      14PFA

Safety Precautions

Refer to Safety Precautions for All Level Controllers.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                  In the interest of product improvement, specifications are subject to change without notice.

                                                                      7
                                                       Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                            Application Considerations

SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

       Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

       Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
           safety equipment, and installations subject to separate industry or government regulations.

       Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                       Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

OMRON Corporation                                                                                                                                        2009.9
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                                                   (c)Copyright OMRON Corporation 2009 All Right Reserved.
http://www.ia.omron.com/
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved