datasheet

电子工程世界电子工程世界电子工程世界

型号

产品描述

搜索
 

5954-BK

器件型号:5954-BK
器件类别:连接器    电源连接器   
厂商名称:Anderson Power Products
下载文档

器件描述

Heavy Duty Power Connectors BUSH.250MCM TO #4/0(B01960P1)

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Anderson Power Products
产品种类:
Product Category:
Heavy Duty Power Connectors
商标:
Brand:
Anderson Power Products
产品类型:
Product Type:
Heavy Duty Power Connectors
子类别:
Subcategory:
Power Connectors

5954-BK器件文档内容

                                            Legal Info & Global Presence

APP® Global Distribution Network Includes the Following Countries Along With Many Others:

Argentina, Australia, Belgium, Brazil, Canada, Chile, China, Columbia, Denmark, France, Germany, Greece, Hong Kong, Ireland,

Israel, Italy, Japan, Mexico, New Zealand, Norway, Peru, Poland, Portugal, Singapore, Slovenia, South Africa, South Korea, Spain,

Switzerland, Thailand, Turkey, United Kingdom and United States.

APP®’s philosophy is to provide products and services within the trading markets of our customers. We currently serve

our worldwide customer base from customer support and manufacturing facilities in Sterling, MA, U.S.A., Warrington

UK for European customers, as well as three Asia Pacific facilities: Shenzhen, China, Shatin Hong Kong and Taichung

City 407, Taiwan (R.O.C.).

Today, as a result of innovative design and development, APP® has evolved into a valued supplier for a wide variety of

markets including Back-up Power, Telecom / Datacom, Alternative Energy Generation & Distribution, Medical Equipment,

Defense, and the Material Handling Industries.

APP® has established a reputation for high quality products, on-time deliveries, and excellent customer service. As a

result of modern manufacturing techniques and rigorous quality control measures, APP® assures customers receive

the quality products they deserve.

As a global company dedicated to best environmental practice, APP® has taken steps to meet the RoHS directive for

virtually all products. The RoHS status for individual APP® products is readily accessible to customers twenty-four hours

a day, seven days a week online. APP® looks forward to the challenges posed by the new technologies of the future and

will continue its century long tradition of design excellence and superior customer support to meet customers’ needs.

Anderson Power Products® may revise terms and conditions from time to time without notice. APP® maintains this catalog as a service to its customers. The entire content

(images and text) is ©copyrighted 2012 and may not be distributed, downloaded, modified, reused, reposted, or otherwise used, except as provided herein, without the

express written permission of APP®. You may use and download the content only for your personal, non-commercial use.

APP® will use reasonable efforts to include accurate and up-to-date content in the catalog. All product information contained in the catalog including ordering information,

illustrations, specifications, and dimensions, are believed to be reliable as of the date of publishing, but is subject to change without notice. APP® makes no warranty or

representation as to its accuracy. Content in the catalog may contain technical inaccuracies, typographical errors and may be changed or updated without notice. APP®

may also make improvements and/or changes to the products and/or to the programs described in the content at any time without notice. Current sales drawings and

specifications are available upon request.

Neither APP® nor any party involved in creating, producing, or delivering this catalog shall be liable for any direct, incidental, consequential, indirect, or punitive damages

arising out of your use of this catalog or any errors or omissions in its content.

All product names, whether or not appearing in large print or with the trademark symbol, including, but not limited to A, A in circle , Anderson Power Products, Anderson,

APP, Powerpole, SB, SBE, SBO, SBS, SBX, SPEC Pak, Saf-D-Grid, Power Clip, Power Drawer, PowerMod, are trademarks of APP, its affiliates, related companies,

licensers, and/or joint venture partners. The use or misuse of these trademarks, or any other content of this catalog, except as permitted herein, is expressly prohibited

and may be in violation of intellectual property laws, which shall be aggressively enforced.
SECTION 1                                                                   SECTION 3

• Index & Product Selector ..............................               1   • Multipole Connectors .......................................       44

• Technical Reference .....................................             4                         - SBS® ...................................................   49

• Glossary ........................................................ 10                            - SB®50 .................................................    57

• Engineering Reference ................................. 12                                      - SB®120 ...............................................     62

                                                                                                  - SB®175 ...............................................     66

SECTION 2                                                                                         - SB®350 ...............................................     71

• Powerpole® Connectors ............................... 16                                        - SBE®80 / SBO®60 ...............................            77

                  - PP15 to PP45 ....................................... 20                                     - SBE®160 / SBX®175 ...........................              82

                  - Powerpole® Pak .................................... 23                                      - SBE®320 / SBX®350 ...........................              88

                  - Powerpole® PP75 ................................. 30

                  - Powerpole® PP120 ............................... 36                   SECTION 4

                  - Powerpole® PP180 ............................... 39                   • Tooling .........................................................  95

                                                                            SECTION 5

                                                                            • Part Number Page Reference .....................                   101

                                           Powerpole® Connector             Family  Multipole Connector Family

           Page Number                                                  16             44

           Amps (UL) Per Pole                                Up to 350                 Up to 450

           Volts (UL) Per Pole                               Up to 600                 Up to 600

           Wire Gauge (AWG)                                  20 - 3/0                  16 - 300 mcm

           Wire Gauge (mm²)                                  0.5 - 85.0                1.3 - 152

           Number of Power Circuits                          1 / Stackable             2 - 3 / Not Stackable

           Ground                                                       ●              ●

           Auxiliary                                                                   ●

           PCB Mount                                                    ●              ●

           Bus Bar                                                      ●              ●

           Panel Mount                                                  ●              ●

           Blind Mate                                                   ●

           Hot Plug                                                     ●              ●

           Touch Safe                                                   ●              ●

           Strain Relief                                                ●              ●

           Polarized Housing                                            ●              ●

           Mechanically Keyed                                                          ●

           Latching                                                     ●

           Handle                                                                      ●

           Air Supply System                                                           ●

All Data Subject To Change Without Notice                                                            www.andersonpower.com                            -1-
                                       APP Custom Connector Capabilities

           Index / Prod. Selector  Anderson Power Products® specializes in design and manufacture of high current connection systems to meet specific

                                   customer needs. Our expertise in high amperage connections, multiple types of contact technology, and molded

SECTION 1                          plastic insulators allow us to provide durable, high power connections that fulfill the project requirements of OEM’s.

                                   We look forward to working with OEM’s on their manufacturing scale projects to provide connector solutions which

                                   our current product portfolio may not satisfy. APP® Marketing, Engineering, Quality, Safety Agency, and Manufacturing

                                   teams all contribute through the integrated product development process to create and deliver custom connectors

                                   that exceed our customers’ needs and meet APP® high standards.

                                   Contact your local customer service representative or regional sales manager to explore how APP® custom design

                                   and manufacturing capabilities can meet your high volume connection needs.

                                   | How to Use this Catalog |

                                   The information in this catalog is provided in layers to allow you to quickly find the information you are looking for.

                                   1) Selection Guides are featured at the front of the catalog and at the beginning of each product section to enable quick

                                       connector selection by electrical attributes and other features.

                                   2) A Technical Reference is provided to give important information common to all connectors in this catalog. Answers

                                                     to common questions, definitions of terminology, and technical charts are all included.

                                   3) Overviews at the beginning of each product main section describe the similarities and call out common features of

                                                     products within that section.

                                   4) Introductions to the features and benefits of each product are supplied at the beginning of each sub-product

                                                     section (SB®50, SB®120, etc).

                                   5) Specifications and Temperature Charts are shown after the main connector components in each sub-product

                                       section to provide detailed technical information (SB®50, SB®120, etc).

                                   6) Tooling Charts are provided at the end of each connector family (SB®, SBS® etc) to quickly identify the correct tooling.

-2-                                www.andersonpower.com                                                                        All Data Subject To Change Without Notice
| Product Selection Worksheet |

Prior to selecting an interconnect solution from Anderson Power Products®, we recommend you gather the following                Index / Prod. Selector  SECTION 1

information. This will aid you in quickly identifying the best product for your particular need.

Amps

      Continuous    ________________                                              max amps at  ___________   volts

      Peak      _____________________                                             max amps    ___________    seconds

Temperature

      Operating _____________                                                            Storage  ____________

Circuit Definition

                                  Number of Circuits:                                           Wire Gauge:

      Power         ____________________                                          ________________________

      Ground        ____________________                                          ________________________

      Auxiliary ____________________                                              ________________________

      Other         ____________________                                          ________________________

Application

      □   PCB to PCB                                            □  Wire to PCB                           □  Wire to Bus Bar                        □ Wire to Wire               

      □   Wire to Panel                                         □  Other _______________________________

Mounting Method (if applicable)

      □   PCB                                                          □  Panel                                        □  Blind Mate

Contacts

      □   Mating Cycles                    _____  □  Individual                            □  Reeled

      □   Tin                                                          □  Silver                                       □  Gold

      □   Straight                                              □  Right Angle

Other Features

      □   Hot Plug                                                                                              □ Touch Safe per _______

      □   Flame Resistance per ___________                                                 □  IP rating of __________

      □   Sequencing                                                                                            □  Strain Relief

      □   Polarized Housing                                                                              □  Mechanical Housing Key

      □   Latching                                                                                              □  Handle               

      □   Other _____________________________________________________________________________________

      ____________________________________________________________________________________________

      ____________________________________________________________________________________________

NOTES:

All Data Subject To Change Without Notice                                                                www.andersonpower.com  -3-
SECTION 1  Technical Reference  | General Application Notes |

                                There are common considerations when using APP® connectors. Additional considerations may apply based on the

                                particular connector being used, the application, and conditions in which the connector is being used. This information

                                is intended to provide a basic understanding and is provided for reference only. APP® connectors should be assembled

                                and used according to the equipment manufacturer’s instructions, as well as in compliance with local and international

                                electrical codes.

                                The maximum amperage ratings provided in the specifications are based on use of APP® recommended assembly

                                tooling and the maximum wire size for the connector being used. Amperage ratings are based on not exceeding the

                                maximum operating temperature of the connector housing, factoring in an ambient temperature of 25°C or 77°F.

                                A wire with an appropriate insulation temperature rating should be selected to meet or exceed the total connector

                                temperature (heat rise + ambient).

                                As an example: if the maximum operating temperature for a connector operation is 105°C and the ambient temperature

                                is 25°C, the maximum heat rise attributable to the connector is 105°C - 25°C = 80°C. The expected heat rise based

                                on the connector and wire size used can be estimated using the heat rise charts, but should be confirmed by testing

                                in the specific application with the specific wire to be used.

                                Connector devices are rated or derated by the wiring configuration and the environment. Factors to be considered include:

                                enclosure characteristics, connector housing and wire insulation characteristics, number of wires in an enclosed area

                                such as a raceway or conduit, as well as the ambient temperature.

                                Underwriter Laboratories Inc. amperage ratings are based on not exceeding the maximum operating temperature of

                                the connector housing. This means connectors can be extremely hot when used at the UL amperage ratings. For this

                                reason UL amperage ratings should only be applied to connectors when they are used inside an enclosure not accessible

                                to untrained persons. Canadian Standards Association ratings are based on not exceeding a 30°C temperature rise

                                above ambient temperatures. For this reason CSA amp ratings are a good point of reference for connectors that are

                                user operated. APP® does not recommend exceeding a 30°C temperature rise above ambient temperatures for connections

                                accessible during operation to untrained persons.

                                | How to Read Temperature Charts |

                                Tempearture Rise at Constant Current Charts

                                                                                                                                                        SB®50

                                Temperature Rise at Constant Current charts show the associated heat rise                                   Temperature Rise at Constant Current

                                                                                                                                     60

                                as a result of applied current to the connector. An example of the SB®50

                                Temperature Rise chart is included to follow along with this explanation.                            50

                                                                                                                   Temperature (°C)  40

                                The  chart  is  based  on  an  ambient  temperature  of         25°C  (77°F  room

                                temperature). Accordingly if the temperature °C on the Y axis of the chart is at                     30

                                30°C, the expected total connector temperature would be 55°C.                                        20

                                Separate curves are shown for #6, #8, #10, and #12 AWG wire. Interpreting                            10

                                the curves, if 50 amps are applied continuously to the connector, the heat rise                      0

                                will be 23°C for #6, 35°C for #8, 55°C for #10, and #12 wire is not suitable for                         0  10  20  30  40  50  60   70  80       90

                                this amperage.                                                                                                      Amperes Applied

                                                                                                                                                6 AWG                8 AWG

                                Where T = Temperature, heat rise is expressed as a ΔT°C.                                                        10 AWG              12 AWG

                                T ambient - T (ambient + heat from applied current) = ΔT°C.

-4-                             www.andersonpower.com                                                                                           All Data Subject To Change Without Notice
Derating vs. Ambient Temperature Charts                                                                                                            Technical Reference  SECTION 1

Derating vs. Ambient Temperature charts show the maximum amperage                                                   SB®50

capability of a connector at a given ambient temperature. An example of                              Derating vs. Ambient Temperature

the SB®50  chart is included to follow along with this explanation.                          125

All data points are based on the maximum operating temperature of the      Temperature (°C)  100

connector, most often 105°C or 221°F. Accordingly if the temperature °C

on the Y axis of the chart is at 105°C, there is no amperage capability                      75

because the connector housing is already at the maximum operating

temperature.                                                                                 50

Separate curves are shown for #6, #8, #10, and #12 AWG wire.                                 25

Interpreting the curves, at a 75°C ambient temperature the maximum                                0  10  20  30  40  50    60  70  80  90  100

amperage capability that can be applied continuously to the connector is:                                        Amperes Applied

58A for #6, 46A for #8, 37A for #10, and 31A for #12 wire.                                                   6 AWG                 8 AWG

                                                                                                         10 AWG                12 AWG

Notes on Temperature Rise Charts

Note that these charts are constructed using calculations based on actual test data. For this reason the chart

information may vary slightly from the safety agency ratings. Safety agency ratings and compliance with electrical

codes take precedent over these charts. The charts are designed to provide a guideline as to the connectors’ capability.

Actual results can vary based on the specific wire used, crimp tooling and assembly, as well as the environment the

connector is used in.

CSA ratings are based on not exceeding a 30°C temperature rise above ambient or a total temperature of 55°C. This

is considered the maximum temperature to safely handle a connector at. UL ratings can be based on the operating

temperature limit of the connector. Often for APP® connectors this is 105°C or an 80°C temperature rise above an

ambient temperature of 25°C. To provide a margin of safety, the heat rise charts are limited to a 60°C temperature rise.

| Compatible Wires |

Al                 Cu

APP® connectors are designed to be crimped and/or soldered to multi-stranded copper conductor wires only.

Alternate conductor materials including aluminum should not be used. Aluminum conductors crimped into APP®

contacts can result in a galvanic reaction occurring between the aluminum wire and the more cathodic metals

used in APP® contacts including copper, tin, silver, and gold. Additionally softer metals like aluminum flow or

loosen from crimps much easier than copper.

Multi-stranded wire is recommended for all APP® connectors and is required when crimp terminating wires or when a

connector with flat wiping contact technology is used (such as Powerpole® and SB®). Solid wires do not adequately

compress and retain in crimp barrels after being crimped. For this reason if solid wire is used, it should be with solder

termination only.

Solid wires also do not flex and bend as easily as multi-stranded equivalents and can act as a lever arm and impede

or alter the natural state of a flat wiping contact in the housing. This impediment or alteration to the flat wiping contact’s

natural state can cause intermittency and shorts as well as higher resistance and temperature at a given amperage

than is shown in APP® specifications. Mating and unmating forces may also be impacted.

All Data Subject To Change Without Notice                                                                    www.andersonpower.com              -  5  -
                                | Different Contact Technologies |

           Technical Reference  Flat Wiping:

                                • Same contacts on the “male” and “female” side reduce inventory costs and increase ease of assembly.

                                • Low resistance connection has a large conducting surface and a high normal force in comparison to typical pin

SECTION 1                                        and socket contacts.

                                • Sacrificial tip confines damage to non-conducting area when mating or breaking under load.

                                • Raised surface on the mating side of the contacts secures the connector in the mated condition, limiting the                

                                                 need for latching on outer housings.

                                • Over wiping design cleans the mating surface when mating and unmating.

                                                                                         - VS -

                                               Solid line

                                               of electrical                                                  Select points of

                                               contact.                                                       electrical contact.

                                Flat Wiping Technology                                           Pin & Socket Technology

                                Pin & Socket:

                                • Different contacts on male and female sides. Female socket contacts are typically more expensive than the                

                                                 simple geometries of the pin contacts.

                                • Often higher resistance than flat wiping connectors of the same wire size and plating due to the reduced mating

                                                 surface area and lower normal force. Gold plating often used to compensate and minimize resistance.

                                • Best for compact connection needs such as signal and low power due to static position in housings and                

                                                 symmetrical shape.

                                • Socket contacts can catch and hold debris inside the socket body causing mating problems.

                                | Use of APP® Connectors in Applications Exceeding 600V |

                                The approved voltage ratings for APP® connectors are usually limited by the category under which a safety agency

                                such as UL approves our connector for use. UL typically defers to National Electric Code (NEC) on the voltage limitations

                                for any given device our connector could be used in. For most common applications NEC restricts voltage to a maximum

                                of 600V AC or DC which is what our connector voltage ratings are based on.

                                To achieve UL 1977 approval for a 600V rating, we test our connectors for dielectric withstanding voltage. The connector

                                is tested at 2 times the rated voltage of 600V plus 1000V or 2200VAC for 1 minute. For applications exceeding 600V,

                                UL / NEC / IEC may require application specific review for creepage and clearance resistance.

                                | Frequently Asked Questions |

                                Q: Can I cross mate low and high mating force contacts?

                                A: Yes, however this would not be a connection solution we have tested for safety agency approval. Additionally the

                                contacts may wear at an accelerated rate causing the mating cycle rating to be reduced. The mating and unmating

                                force expected would be somewhere in between the high and low mating force specification.

                                Q: Can I crimp multiple wires into 1 crimp barrel?

                                A: Yes, however this would not be a connection solution we have tested for safety agency approval. Particular care

                                should be used that the bundle of wires do not interfere with the movement of the contact in the housing during mating

                                and unmating (see maximum wire O.D. specification). The total circular mils of all conductor stands should be within

                                + or – 5% of the wire size the contact is intended for. Twist the conductor strands together and crimp using APP®

                                tooling with range taking capabilities such as the 1368 series. To crimp with other APP® recommended tools, contact

                                customer service for the recommended setting or die and locator combination.

-6-                             www.andersonpower.com                                                                              All Data Subject To Change Without Notice
Q: Will the crimp tool I have for standard color-coded lugs, Mil Spec contacts, or another connector                       Technical Reference  SECTION 1

manufacturer, work for crimping APP® contacts?

A: No. APP® contacts generally do not conform to standard crimp barrel dimensions used for lugs, Mil Spec contacts,

or other connector manufacturers. The tooling recommended by APP® must be used to ensure the performance

designed by APP® is achieved. Alternate tooling will void APP® warranties and can affect safety agency approvals. In

some instances Mil Spec tools are approved for crimping contacts with the dies and locators recommended by APP®.

See tooling charts for specific instances, or contact customer service for more information.

Q: Can metric sized wires be used with APP® contacts?

A: Yes. The majority of our crimp tooling recommendations are based on testing and verification we have performed

with AWG sized cables. Metric cables of the same or slightly smaller circular mils equivalent to the AWG wire recommended

can typically be successfully terminated in APP® contacts. There is a wire conversion chart at the end of this catalog

section that can be used as a reference when converting AWG to mm² sizes. The 1368 series crimp tooling has a

range taking capability that produces a reliable crimp with metric equivalents of AWG cables. Please contact customer

service for metric tooling recommendations for other APP® crimp tools.

Q: Are APP® connectors suitable for use in applications where the voltage exceeds 600V AC/DC?

A: Possibly. See “Use of APP® Connectors in Applications Exceeding 600V”, contact customer service with further

questions.

Q: How do Powerpole® and Multipole connectors stay securely mated without latches?

A: The proven flat wiping technology used in these connectors features a detent or bump in the contact surface along

with powerful stainless steel springs that hold the connectors in the mated position. High mating force contacts have

a detent that is raised higher than low mating force contacts. The higher the detent, the more force is required to mate

and unmate the contacts. In many applications the detent and spring force is enough to securely hold the connectors

in the mated position without the need for latches. Latching shells, clips, or other external devices can be used to

secure flat wiping connectors in applications where shock, vibration, or cable strain may overcome the inherent force

holding the connectors together.

Q: How does APP®’s genderless connector design work to make a mated pair.

A: Genderless Powerpole® and Multipole housings do not have a male(pin) and female(socket) side. For wire-to-wire

applications the exact same housings and contacts are used on both sides of the mated pair. If your application calls

for wire-to-PCB or wire-to-busbar connections then different contacts and possibly housings will be required on each

half (similar to male and female connectors).

To make a mated pair of Powerpole® or Multipole connectors simply assemble the connectors closely following the

assembly instructions. After each connector half is fully assembled take one half and flip it over. The two halves will

mate together. Multi-row Powerpole® assemblies will need to be stacked in mirror images of each other to properly

mate the correct circuits. This information is detailed at the beginning of the Powerpole® section.

All Data Subject To Change Without Notice                                                     www.andersonpower.com        -7-
                                | Touch Safety & Ingress Protection (IP) |

           Technical Reference  UL 1977 Section 10.2:

                                Typically required for applications where the connector is external to the end device and operating over 30V or 200A,

SECTION 1                       where wet conditions may be present (600V category).

                                Testing is performed using a probe that mimics a child’s finger. All features of the connector are tested for live parts

                                in the unmated state (no pressure applied). A smaller 3 mm probe is then applied in the mated state to test for live

                                parts. Note that some applications may require the connector to not expose live parts to the 3 mm probe in the mating

                                interface.

                                IEC 60950:

                                From the standard for Information Technology Equipment Safety, the requirements are harmonized with UL1950. Typically

                                required for commercial and industrial applications where operators may need some degree of protection while acessing

                                or servicing equipment.

                                Testing is performed using a probe that mimics an adult finger. All features of the connector are tested for live parts in

                                the unmated state with 30 N of force applied to the probe.

                                IEC 60529:

                                Standard for Degrees of Protection Provided by Enclosures is harmonized with EN 60529.

                                Protection degree number is assigned to both solids and liquids in that order. For example: a connector with an IP20 rating

                                is protected against fingers, but has no protection against ingress of liquids. APP® takes a conservative approach in rating

                                our connectors against liquid ingress and consider any meaningful water ingress to have a harmful effect.

                                Protection               Solids (First Digit)                               Liquids (Second Digit)

                                Degree         Description     Protected Against            Description                Protected Against

                                            0               Not Protected                                              Not Protected

                                                               Large body part such as      Vertically dripping water  Duration: 10 minute

                                            1  > 50 mm         back of hand                 (no harmful effect)        Water: 1 mm / minute rainfall

                                                                                                                       Pressure: N/A

                                                               Adult fingers or similarly   Tilted 15 degrees up       Duration: 10 minute

                                            2  > 12.5 mm       sized objects                dripping water             Water: 3 mm / minute rainfall

                                                                                            (no harmful effect)        Pressure: N/A

                                                               Typical screw drivers or     Water spray up to 60       Duration: 5 minute

                                            3  > 2.5 mm        large wires                  degree angle               Water: 0.7 liter / minute

                                                                                            (no harmful effect)        Pressure: 80-100 kN/m²

                                                               Small pointy tools and       Water splash from          Duration: 5 minute

                                            4  > 1 mm          small wires                  any direction              Water: 10 liter / minute

                                                                                            (no harmful effect)        Pressure: 80-100 kN/m²

                                                               Complete physical            Water jet from any         Duration: 3+ minute

                                            5  Dust protected  protection, no functional    direction                  Water: 12.5 liter / minute

                                                               interference from dust       (no harmful effect)        Pressure: 30 kN/m² @ 3 m distance

                                                               Complete physical            Strong water jet from      Duration: 3+ minute

                                            6  Dust sealed     protection and sealed        any direction              Water: 100 liter / minute

                                                               from dust ingress            (no harmful effect)        Pressure: 100 kN/m² @ 3 m distance

                                                                                            No ingress of water        Duration: 30 minute

                                            7                                               in harmful quantity        Water: Immersion

                                                                                            when immersed up           Pressure: 1 m depth

                                                               N/A                          to 1 m depth

                                                                                            No ingress of water        Duration: Mfg. specified

                                            8                                               in harmful quantity        Water: Immersion

                                                                                            when subject to tests      Pressure: 1+ m depth. Mfg. specified

                                                                                            in excess of condition 7

-8-                             www.andersonpower.com                                                                                 All Data Subject To Change Without Notice
| Preventative Maintenance |

Damaged connectors, contacts and cables may present hazards, resulting in inefficient battery and charger operation.                  Technical Reference  SECTION 1

To avoid these problems, conduct the following maintenance checks at least once annually. When you see a problem,

take corrective action   immediately.

1.  Dirty Connectors

When engaged and disengaged, the contact surfaces of Anderson SB® Connectors “over wipe,” thus providing

a self cleaning action.                    To ensure the continued benefit of this feature, clean the contact surfaces and lubricate

the connector.   Use a “white” lithium grease, which may be obtained from hardware stores and automotive parts

suppliers.

2.  Melting Connectors

Connector housings overheat and melt for many reasons. To prevent this:

    A. Examine the crimp between cable and contact.  Ensure the crimp tooling recommended by APP® has been

                  used.       Improper crimping, corrosion, and broken wires result in unnecessary resistance causing the contact

                  to heat up.

    B. Check contact surfaces for signs of    “pitting” caused by dirt or disengaging connectors under load.  One

                  badly pitted contact, particularly in a connector attached to a battery charger, can lead to pitting on surfaces

                  of other contacts. If not corrected, this can result in an epidemic of bad connectors throughout a fleet of electric

                  vehicles and in chargers and batteries.

    C. Check to see if batteries are being disconnected while the charger is still on. This causes the contacts to arc                

                  at the tips, resulting with progressive pitting and silver removal from tip to crown.     If this practice is occurring,

                  discontinue it now to avoid major repairs in the future.

3.  Other Conditions

If any of the following conditions exist, the connector housing, contact and/or cable should be replaced immediately.

    A. Housing: Cracks, missing pieces, evidence of excessive heat, discoloration. You may consider replacing the existing

                  housing with a Chemical Resistant equivalent for improved durability against UV rays and common solvents and

                  hydrocarbons.

    B. Contacts:  Pitting, burns, corrosion, excessive wear, cracked crimp barrels,

                  discoloration.

    C. Cable:   Exposed copper near housing, cracked cable, peeling or frayed insulation.

    D. Handles:   Loose attachment and signs of damage as missing or loose hardware

    and cracked or broken plastic (Handles should be used for connectors that are

    hard to reach or move.)

    E. Cable Clamps:     Loose attachments, signs of abraded cable jacket, missing

                  or loose hardware.                     (Cable clamps should be used to relieve strain on

                  unmounted cable.)                                                                         Uncrimped Good  Damaged

                                                                                              Contact         Contact

                                                                                                                           B

                                           A

All Data Subject To Change Without Notice                                                     www.andersonpower.com                   -9-
SECTION 1            Amp / Ampere: Measurement increment of electric current. Abbreviated         Flammability: The measure of a material’s ability to support combustion.

                     as “I”.                                                                      Often tested per UL94.

           Glossary  Applicator: A semi-automatic termination machine consisting of an            Flat Wiping: The sliding action which occurs when contacts are mated.

                     upper and lower half that is used to crimp contacts onto wire. Used in       Wiping has the effect of removing small amounts of contamination from

                     conjunction with an electrical/ mechanical press.                            the contact surfaces, thus establishing better conductivity.

                     AWG: American Wire Gauge. A standard system for designating wire             Genderless: See “Hermaphroditic”

                     diameters.

                                                                                                  Heat Rise: Temperature rise associated with the electrical load applied

                     Blindmate: To join two connector halves in a normal engaging mode            to a mated connection.

                     without visual orientation.

                                                                                                  Hermaphroditic (Genderless) Connector: A connector in which both

                     Busbar: Three dimensional constructions enabling electrical distribution     mating members are exactly alike at their mating face. There are no

                     of current in power electronic modules. Typically constructed of cop-        male or female members, but designs provide correct polarity.

                     per, busbars are most frequently used in power dense applications

                     where the busbar offers a cost or space savings over wire.                   Hot Plug / Hot Swap: Live connector insertion / extractions.

                     Color Coding: A system of identification for terminals and related devices.  IEC: International Electrotechnical Commission, a standard writing

                                                                                                  organization.

                     Contact Resistance: The electrical resistance of metallic surfaces

                     at their interface in the contact area under specified conditions when       Insulation Resistance: Ratio of applied voltage to the total current

                     carrying a specified test current.                                           between the two electrodes in contact with a specific insulation.

                     Contact Retention: Minimum axial load in either direction which a            IP: Ingress Protection, a standard per IEC 60529 for measurement of

                     contact must withstand while remaining firmly fixed in its normal position   ingress for solids and liquids into an enclosure.

                     within a housing.

                                                                                                  Locator / Positioner: Device for positioning contacts into crimping dies.

                     Crimp Retention: The axial load which a contact can withstand without

                     separation from the wire.                                                    Make-First     /  Break-Last  (Premate):  Sequencing  of      contact(s)   so

                                                                                                  that they engage prior to the main power contacts. Typically used

                     Crimp Termination: A connection in which a metal sleeve is secured           for ground / positive earth / neutral positons as a protective measure

                     to a conductor by mechanically deforming the sleeve with presses or          against excess currents, short-circuits, and ground faults.

                     automated crimping machines, eliminating the need for solder. Not

                     suitable for solid (non-stranded wires).                                     Make-Last / Break-First (Postmate): Sequencing of contact(s) so that

                                                                                                  they engage after the main power contacts. Typically used for signal or

                     CSA: Canadian Standards Association, a safety standard writing and           auxiliary power positions to ensure communications are not started or

                     testing organization.                                                        power circuits switched on until the power contacts are fully engaged.

                     Cycle Controlled: To determine if repetitive on/off conditions result        Mating Force: Force required to join two connector halves in a normal

                     in degrading the contact system which may lead to failures such as           engaging mode.

                     “thermal run away”.

                                                                                                  Modular: Refers to similar parts or modules used as building blocks. A

                     Detent: A bump or raised section projecting from the surface of a contact    modular connector is one in which similar or identical sections can be

                     for keeping the contact in position relative to another and released by      assembled together to provide the appropriate connector type or size

                     greater force.                                                               for the application.

                     Dielectric Strength (Withstanding Voltage): The highest potential            Ohms: Measurement increment of resistance.

                     difference (voltage) that an insulation material of given thickness can

                     withstand for a specified time without occurrence of electrical breakdown    Operating      Temperature    Range:  Connector    temperature     rating

                     through its bulk.                                                            established by materials used, plastic, finish, and the base metal.

                                                                                                  Applying an electrical load will result in a temperature rise that is

                     Finger Proof: A connector intended for usage external to the end             additive to the operating ambient.

                     equipment shall have live parts protected against exposure to contact

                     by persons when assembled, installed, and mated as intended, as              PCB: Acronym for Printed Circuit Board

                     determined by UL Articulated probe.

                                                                                                  Polarization: A technique of eliminating symmetry so that parts may

                                                                                                  only be mated one way.

- 10 -               www.andersonpower.com                                                                                                  All Data Subject To Change Without Notice
                                                                                                                                                       Glossary  SECTION 1

Pulse (Surge) Current: Highest instantaneous current that will run            Storage Battery: A voltaic battery consisting of two or more storage

through a system.                                                             cells. Energy is accumulated by chemical activity in the charging

                                                                              process and released on demand in the form of electric current.

REACH: The European Community Regulation on chemicals and their

safe use. It deals with the Registration, Evaluation, Authorization and       Strain Relief: A means of termination or installation that reduces the

Restriction of Chemical substances.                                           transfer of mechanical stress from the conductor.

Reducing Bushing: Separate tubular sleeve used to downsize the                Termination: Means of joining contacts to a conductor.

diameter of a crimp barrel to accept a smaller size wire.

                                                                              Touch Safe: See “Finger Proof”

Reeled Contacts: Contacts attached to a feeder strip for use in a high

volume crimping tool.                                                         Turret / Positioner: See “Locator”

Resistance: The opposition to the passage  of  an          electric  current  TUV: The TÜV Rheinland Group is provider of technical services that

through that element. Abbreviated as “R”.                                     certifies products to standards written by other organizations.

RoHS: Restriction of Hazardous Substances Directive. The European             UL: Underwriters Laboratory, a safety standard writing and testing

directive on the restriction of the use of certain hazardous substances       organization.

in electrical and electronic equipment.

                                                                              Volts: Measurement increment of electric potential. Abbreviated as “E”.

Sacrificial Tip: An area of a contact system that absorbs electric arching

to limit damage to the actual mating surface of the contacts.                 VDE: A German standard writing and testing organization responsible

                                                                              standards and safety specifications covering the areas of electrical

Self-Wiping: The sliding action which occurs when contacts are mated.         engineering, electronics and information technology.

Wiping has the effect of removing small amounts of contamination

from the contact surfaces, establishing better conductivity.                  Watt: Measurement increment of electric power. Abbreviated as “W”.

Spring Loaded: A means of providing contact normal force with the

use of a mechanical spring.

All Data Subject To Change Without Notice                                                                         www.andersonpower.com                - 11 -
SECTION 1  Engineering Reference  | Conversion Chart                for American Wire Guage to       Metric  System |

                                                                                Approximate                                                       Approximate

                                  AWG        Metric          Circ.  Equivalent  Wire Diameter  AWG   Metric  Circ.                    Equivalent  Wire Diameter

                                  Size       mm²             Mils   Circ.Mils   in.    mm      Size  mm²     Mils                     Circ.Mils   in.      mm

                                  -          0.5             -      937         0.032  0.81    1/0   -       106mcm*                  -           0.373    9.46

                                  20         -               1020   -           0.036  0.91    2/0   -       133mcm*                  -           0.419    10.60

                                  -          0.75            -      1480        0.039  0.99    -     70      -                        138.1mcm    0.430    10.90

                                  18         -               1620   -           0.046  1.16    3/0   -       168mcm*                  -           0.471    12.00

                                  -          1               -      1974        0.051  1.30    -     95      -                        187.5mcm    0.504    12.80

                                  16         -               2580   -           0.051  1.29    4/0   -       212mcm*                  -           0.528    13.40

                                  -          1.5             -      2960        0.063  1.60    -     120     -                        237.8mcm    0.567    14.40

                                  14         -               4110   -           0.073  1.84    -     -       250mcm                   -           0.575    14.60

                                  -          2.5             -      4934        0.081  2.06    -     150     300mcm                   -           0.630    16.00

                                  12         -               6530   -           0.092  2.32    -     -       350mcm                   -           0.681    17.30

                                  -          4               -      7894        0.102  2.59    -     185     -                        365.1mcm    0.700    17.80

                                  10         -               10380  -           0.116  2.93    -     -       400mcm                   -           0.728    18.50

                                  -          6               -      11840       0.126  3.21    -     240     -                        473.6mcm    0.801    20.30

                                  8          -               16510  -           0.146  3.70    -     -       500mcm                   -           0.814    20.70

                                  -          10              -      19740       0.162  4.12    -     300     -                        592.1mcm    0.891    22.60

                                  6          -               26240  -           0.184  4.66    -     -       600mcm                   -           0.893    22.70

                                  -          16              -      31580       0.204  5.18    -     -       700mcm                   -           0.964    24.50

                                  4          -               41740  -           0.232  5.88    -     -       750mcm                   -           0.999    25.40

                                  -          25              -      49340       0.260  6.60          400     -                        789.4mcm    1.026    26.10

                                  2          -               66360  -           0.292  7.42    -     -       800mcm                   -           1.032    26.20

                                  -          35              -      69070       0.305  7.75    -     500                              986.8mcm    1.152    29.30

                                  1          -               83690  -           0.332  9.43    -     -       1000mcm                  -           1.153    29.30

                                  -          50              -      98680       0.365  9.27    -     625     -                        1233.7mcm   1.287    32.70

                                  * Rounded  for simplicity

                                  NOTE: The above wire diameters and circular mils are based on an average of the most commonly available wires. The wire

                                  manufacturer’s specification should be referenced for information specific to the wire being used.

- 12 -                            www.andersonpower.com                                                                               All Data Subject To Change Without Notice
|  Volts • Amps • Ohms • Watts Conversion |                                                                 Engineering Reference  SECTION 1

                WR                                      E           E               EI

                                                        R           I

                    W                                     W         W               I² R

                    I                                     R         I²

                    IR                                  W           E²              E²

                                                        E           W               R

   Volts =  Watts x Ohms                   Amperes =         Volts  Ohms =  Volts   W atts =  Volts x Amps

                                                             Ohms           Amps

   Volts =  W atts                         Amperes =         Watts  Ohms =  W atts  W atts =  Amps² x Ohms

            Amps                                             Ohms           Amps²

   Volts = Amps x Ohms                     Amperes =         Watts  Ohms =  Volts²  W atts =  Volts²

                                                             Volts          W atts            Ohms

   Wattage Varies Directly as a Ratio of Voltages Squared.

   W² = W¹  E²  x²

            E¹

   3 Phase Amperes =                       Total Watts

                                           Volts x 1.732

All Data Subject To Change Without Notice                                           www.andersonpower.com   - 13 -
                                                                    | Standard to Metric Conversions |

           Engineering Reference             Approximate Conversions                                 Approximate Conversions

SECTION 1                                 From: Standard / US Customary                              From: SI / Metric Units

                                             To: SI / Metric Units                                   To: Standard / US Customary

                                             When                                                    When

                                             You          Multiply                                   You          Multiply

                                  Symbol     Know         By            To Find      Symbol  Symbol  Know         By           To Find      Symbol

                                                          LENGTH                                                  LENGTH

                                  in         inches       25.4          millimeters  mm      mm      millimeters  0.039        inches       in

                                  ft         feet         0.305         meters       m       m       meters       3.28         feet         ft

                                                          AREA                                                    AREA

                                  in 2       square                     square       mm2     mm 2    millimeters  0.0016       square       in2

                                             inches       645.2         millimeters                                            inches

                                  ft 2                                  square       m2      m2      square       10.764       square feet  ft2

                                             square feet  0.093         meters                       meters

                                                          VOLUME                                                  VOLUME

                                             fluid                                           mL      milliliters  0.034        fluid        fl oz

                                  fl oz      ounces       29.57         milliliters  mL                                        ounces

                                  gal        gallons      3.785         liters       L       L       liters       0.264        gallons      gal

                                  ft 3                                  cubic        m3      m3      cubic        35.314       cubic feet   ft3

                                             cubic feet   0.028         meters                       meters

                                                          MASS                                                    MASS

                                  oz         ounces       28.35         grams        g       g       grams        0.035        ounces       oz

                                  lb         pounds       0.454         kilograms    kg      kg      kilograms    2.202        pounds       lb

                                                      TEMPERATURE                                                 TEMPERATURE

                                  oF         Fahrenheit   (F-32) x 5 /  Celsius      oC      oC      Celsius      1.8C + 32    Fahrenheit   oF

                                                          9
                                                          or

                                                          (F-32) / 1.8

                                             FORCE and PRESSURE or      STRESS                       FORCE and PRESSURE or STRESS

                                  lbf        poundforce   4.45          newtons      N       N       newtons      0.225        poundforce   lbf

                                  lbf/in  2  poundforce   6.89          kilopascals  kPa     kPa     kilopascals  0.145        poundforce   lbf/in2

                                             per square                                                                        per square

                                             inch                                                                              inch

- 14 -                            www.andersonpower.com                                                                      All Data Subject To Change Without Notice
                                           | Scratch Pad |

                                                                                   Engineering Reference  SECTION 1

All Data Subject To Change Without Notice                   www.andersonpower.com  - 15 -
                                                                                        ®

                              Powerpole® Connectors

                              - PP15 to PP180

                                                                                                     This versatile connector series invented by Anderson Power

                                                                                                     Products® meets a wide range of power connection needs.

                                                                                                     There    are  four  basic      housing           sizes  in  the  Powerpole®

                                                                                                     product   family  that     allow     specific    amperage        or          wire  size

           Powerpole® Family                                                                         needs to be filled in the most compact footprint. Powerpole®

                                                                                                     can handle up to 350 amperes per pole and accommodate

                                                                                                     wire ranges of    #20 AWG (0.5 mm²) to 3/0 (70 mm²). A wide

SECTION 2                                                                                            range of colored housing options can be stacked together to

                                                                                                     create a proven reliable custom connector. These housings

                                                                                                     can be used with different contacts to create wire-to-wire,

                                                                                                     wire-to-board,      or     wire-to-busbar               connections.               The

                                                                                                     Powerpole® combines high quality materials and a cost

                                                                                                     effective innovative design to allow powerful versatility.

                                                                                                                   Stackable Modular Housings

                                                                                                                   Available    in  four  sizes   to  right

                                                                                                                   size your connection need

                                                                                                                                                      Color Coded Housings

                                                                                                                                                      Help ensure that connectors

                                                                                                                                                      are assembled and mated

                                                                                                                                                      correctly

                                                Genderless Housings

                                                Provide  simplified  assembly

                                                and minimize the number of

                                                components

                                                                                           Low Resistance Connection

                                                                                           Silver    or  tin  plated  contacts

                                                                                           inside    housings  that   strongly

                                                                                           force the contacts together

                              Self Securing Design

                              Stainless steel springs create

                              a  robust  force  between  the

                              contacts that holds the con-

                              nector in the mated condition,         Hot Plugging AC or DC

                              but allows it to be quickly dis-       Contacts feature a sacrificial

                              connected                              tip that allow high current

                                                                     circuit interrupt

                                                                                                                      Connection Versatility

                                                                                                                      Contacts for wire, PCB,

                                                                                                                      or busbar all fit into the

                                                                                                                      same housings

- 16 -                        www.andersonpower.com                                                                                                   All Data Subject To Change  Without Notice
|  POWERPOLE            FAMILY SELECTION GUIDE                                        |

   Powerpole® Size      PP15 to 45                  Page   #  PP75          Page   #     PP120        Page  #  PP180           Page  #

   Connector Types      Standard                       20     Standard         30        Standard       36     Standard        39

                        Finger Proof                   20     Locking          31                              Busbar          40

                        PCB                            21     Busbar           31

                        Ground                         21     PCB              31

                        Power Pak                      23

   Amps (UL) Per Pole                      0 to 55                  120                   240                          350

   Volts (UL) Per Pole                     600                      600                   600                          600

   Wire Gauge (AWG)                        20 - 10                  16 - 6                6 - 1/0              10 - 3/0                         Powerpole® Family  SECTION 2

   Wire Gauge (mm²)                        0.05 - 6.0            1.3 - 13.3               13.3 - 53.5          5.3 - 85.0

   Number of

   Power Circuits                          1 / Stackable      1  /  Stackable            1 / Stackable         1 / Stackable

   Ground                                  ●

   PCB Mount                               ●                             ●

   Busbar                                                                ●                                                  ●

   Panel Mount                             ●                             ●                         ●                        ●

   Blind Mate           Powerpole® Pak

   Hot Plug                                ●                             ●                         ●                        ●

   Touch Safe                              ●

   Polarized Housing                       ●                             ●                         ●                        ●

   Latching             Powerpole® Pak

   Strain Relief        Powerpole® Pak

Actual Size - Connector Half

                        ............................... Powerpole® Housings ...............................

                        PP15/45                            PP75                    PP120                       PP180

All Data Subject To Change Without Notice                                                                                www.andersonpower.com  - 17 -
                              Powerful Versatility

                              - Create Your Own Custom Connector from Durable Proven Components

                              Powerpole® connectors can be easily customized to each power connection need. Choose from a wide range of

                              colored housings and stack them together into a multiple position connection.    Durable silver or tin plated contacts

                              crimp and poke into housings and are available for a broad range of wire sizes. PCB and busbar contacts can also

                              be simply snapped into place using the same housings. Pre-mate ground / power housings and contacts can be

                              used for safety or sequencing and stack along with standard housings.

                              How to Create Mating Blocks of Stacked Powerpole® Connectors

                              A Single Row Assembly such as the 1x3 shown below will mate to itself. If an assembly has more than one row

                              such as the Two Row Assembly 2x1 shown below, then a different mirror image mating assembly is required.

                              Single Row Assembly 1x3                                                                                             Two Row Assembly 2x1

SECTION 2  Powerpole® Family

                              To Create a Mirror Image Mating Assembly:

                              When mating blocks are viewed with their hoods in the respective orientation (down         or  up), the column position of

                              connectors is unchanged. The rows themselves are mirror images of each other. So           in  the below example, what

                              is column 1 on side A, is column 3 on side B.

                              Side A Hood Down                                                                                                                                  Side B Hood Up
                                         Column 1       Column 2             Column 3  Column 1      Column 2  Column 3

                                                                                       C             B            A          Hood Up

                              Hood Down              A  B                    C

                                                     D  E                    F         F             E         D

                                                     G  H                    I         I             H            G

- 18 -                        www.andersonpower.com                                                                          All Data Subject To Change Without Notice
Use the Same Housings for Wire, PCB, or Busbar Connections

The Powerpole® connection system allows the same housings to hold different contacts for terminating to wire,

printed circuit boards, or busbars. See some of the many ways Powerpole® components can be assembled to

create a custom connection solution.

                       

                                                                Wire-to-Wire

                                                                                                               Powerpole® Family  SECTION 2

                                                                Wire-to-PCB

                                                                Wire-to-Busbar

All Data Subject To Change Without Notice                   www.andersonpower.com                              - 19 -
                                  Powerpole® Connectors

                                  - PP15 to PP45 :                                                              PP15-45 series are the smallest Powerpole® housings. They can be

                                  up to 55 Amps                                                                 used for wire-to-wire or wire-to-board applications. Wire sizes from

                                                                                                                #20 AWG (0.5 mm²) to #10 (6 mm²) offer power capabilities up to 55

                                                                                                                amps per pole. Finger proof housings and the ability to incorporate

                                                                                                                first-mate last-break ground connectors enhance the capabilities of

                                                                                                                this Powerpole® series.

                                                                                                                High Power Density

                                                                                                                • Up to 55 amps in a compact footprint

                                                                                                                Wire-to Wire & Wire-to-Board Configurations

                                                                                                                • Wire & PCB contacts can be used in the same housings

           Powerpole® PP15 to 45                                                                                Finger Proof Housings Available

                                                                                                                • Protects against accidental contact with live circuits

SECTION 2                         | PP15-45 ORDERING INFORMATION |

                                  PP15-45 Finger Proof Housings
                                  Improved on the original APP® design by adding ribs to mating interface to protect against accidental

                                  contact with live circuits. Meets the requirements of UL1977 section 10.2 and is rated IP20. Will not

                                  m         ate w         ith standard housings.                                                                                        PP15-45         Finger Proof  &  Standard & Ground    Housing Dimensions

                                  Description           ------------ Part Numbers ------------              Finger Proof

                                  Minimum Quantity ...        2,500                             200  .....                                                       [ 7.9 ]  Front View

                                  Red                   1327FP-BK            1327FP                         R         ib Fea         ture                                      0.31                       [ 26.6 ]                Mated Length

                                  Green                 1327G5FP-BK          1327G5FP                                                                                                                            0.97

                                  Black                 1327G6FP-BK          1327G6FP                                                                                                     [ 7.9 ]                                           [ 8.4 ]

                                  White                 1327G7FP-BK          1327G7FP                                                                                       0.31                                              0.33

                                  Blue                  1327G8FP-BK          1327G8FP

                                  Yellow                1327G16FP-BK         1327G16FP                                                                                                            [ 41.2 ]

                                                                                                                                                                                                      1.62

                                  PP15-45 Standard Housings                                                                                               45A Premate Ground Housings

                                  The original housing design has an open interface and is available                                                      Green housings are keyed to prevent accidental mating

                                  in a wide array of colors.  Will not mate with finger proof housings.                                                   with standard or finger proof Powerpole® housings.

                                  Description               ------- Part Numbers ------                                                                   Description            ------- Part Number -------

                                  Minimum Quantity     ...    2,500          200                ...                                                                     Minimum Quantity  ...      2,500  200       ...

                                  Red                       1327-BK      1327                                                                                                  Green                  1827G1-BK  1827G1

                                  Green                     1327G5-BK    1327G5               

                                  Black                     1327G6-BK    1327G6

                                  White                     1327G7-BK    1327G7

                                  Blue                      1327G8-BK    1327G8                       

                                  Yellow                    1327G16-BK   1327G16

                                  Orange                    1327G17-BK   1327G17

                                  Gray                      1327G18-BK   1327G18

                                  Brown                     1327G21-BK   1327G21               

                                  Pink                      1327G22-BK   1327G22               

                                  Purple                    1327G23-BK   1327G23

                                  PP15-45 Tin Plated Power Contacts

                                  Offer cost effective performance up to 1,500                  mating cycles.  See specifications and temperature

                                  charts for amperage ratings by wire size.

                                                                                                                                                           Dimensions               

                                                                                              Mating                 Loose Piece     Reeled               -A-

                                  Barrel  AWG               mm²          Force                  -------- Part Numbers -------  inches     mm

                                  Minimum Quantity     .......................................       200        5,000          .........................

                                  Open    14 to 10 K*       2.1 to 5.3   High                   269G3-LPBK      269G3          0.21       5.33

                                  Open    14 to 10 K*       2.1 to 5.3   Low                    261G2-LPBK      261G2          0.20       5.08                                              Open Barrel Contact

                                  Open    14 to 10 SF*      2.1 to 6.0   High                   201G1H-LPBK     201G1H         0.24       6.10

                                  Open    14 to 10 SF*      2.1 to 6.0   Low                    200G1L-LPBK     200G1L         0.24       6.10                                              [ 17.27 ]               [ 6.35 ]

                                  Open    16 to 12          1.3 to 3.3   High                   269G1-LPBK      269G1          0.18       4.57                                                        0.68          0.25

                                  Open    16 to 12          1.3 to 3.3   Low                    261G1-LPBK      261G1          0.18       4.57

                                  Open    20 to 16          0.52 to 1.3  High                   269G2-LPBK      269G2          0.16       4.06                                                        [ 3.81 ]

                                  Open    20 to 16          0.52 to 1.3  Low                    262G1-LPBK      262G1          0.16       4.06                                                                   A

                                  Open    20 to 16 SF*      0.52 to 1.5  Low                    200G2L-LPBK     200G2L         0.20       5.08                                                        0.15

                                  K*  - For #10 AWG class K stranded wire or smaller.                For larger wires use superflex contacts.

                                  SF*- Indicates wires with high stranding such as Super Flex.

- 20 -                            www.andersonpower.com                                                                                                                                     All Data Subject To Change Without Notice
PP15-45 Silver Plated Power Contacts

Maximize performance by offering up to 10,000 mating cycles and are recommended for circuit interrupt or                                                                                     Open Barrel Contact

hot plug applications. See specifications and temperature charts for amperage ratings by wire size. Only closed

barrel contacts are suitable for soldering.                                                                                                                                                  [ 17.27 ]

                                                                                                                                                                                Dimensions                                      0.68                         [  6.35 ]

                                                                                                                                                                                                                             0.25

                                                                     Mating                    Loose Piece                   Reeled                          -A-              - B -               

Barrel       AWG            mm²                 Force             -------- Part Number ---------        Part Number              inches  mm                 inches         mm                                       [ 3.81 ]     A

Minimum Quantity ..........................................       5,000                    200          5,000                    .................................................                    0.15

Open         14 to 10 K*    2.1 to 5.3          Low                  -            261G3-LPBK            261G3                    0.20    5.08         -      -

Open         14 to 10 SF*   2.1 to 6.0          High              -                        -            201G3H                   0.24    6.10                       -      -

Open         14 to 10 SF*   2.1 to 6.0          Low               -               200G3L-LPBK           200G3L                   0.24    6.10                       -      -                               Closed Barrel Contact

Open         16 to 12       1.3 to 3.3          Low               -               261G4-LPBK            261G4                    0.18    4.57                       -      -

Open         20 to 16       0.52 to 1.3         Low               -               262G2-LPBK            262G2                    0.16    4.06                       -      -                               [ 16.26 ]                       [ 7.35  ]

Open         20 to 16 SF*   0.52 to 1.5         Low               -                        -            200G4L                   0.20    5.08                       -      -                               0.64                            0.29

Closed       16 to 12       1.3 to 3.3          Low               1331-BK         1331                                 -         0.15    3.81                 0.10         2.54                                               B

Closed       20 to 16       0.52 to 1.3         Low               1332-BK         1332                                 -         0.12    3.05                 0.07         1.78                                  [ 3.81 ]       A                     Powerpole® PP15 to 45  SECTION 2

K*   - For #10 AWG class K stranded wire or smaller.                      For larger wires use superflex contacts.                                                                                    0.15

SF*- Indicates wires with high stranding such as Super Flex.

45A Premate Ground Wire Contacts

Tin or silver plated contacts are rated for ground or power. Hand tools are available for loose piece                                                                               Open Barrel Premate Contact

contacts. Reeled contacts can be used with high volume press and applicator tooling. Tin contacts

are rated for up to 1,500 mating cycles. Silver contacts are rated up to 10,000 mating cycles.                                                                                      [ 3.6 ]           [ 19.1 ]

                                                                                                                                                 Reeled                                                                              0.14              0.75

                                                                                                                                                                                                   [ 6.4 ]

                                                                        Mating         Loose Piece                   Part                                                                                                  0.25

Type              AWG       mm²                    Force          - Part Numbers -            - Numbers -                                                                                             [ 6.1 ]

Minimum Quantity .............................................               200                 5,000 .....                                                                                          0.24

Open, Tin         14 to 10  2.1 to 6.0             Low            1830G1-LPBK                   1830G1                                                                                       [ 6.1 ]

Open, Silver      14 to 10  2.1 to 6.0             Low            1830G2-LPBK                   1830G2                                                                                       0.24

25A Right Angle PCB Contacts Tin Plated

Suitable for right angle applications up to 25A per pole. Tin plating enhances solderability.

C         anno         t be mixed with 45A PCB contacts. For mating with wire contacts only.

                                                                                                           Dimensions

             Mating                   Loose Piece                         -A-                    -B-

Row          Force     ------- Part Numbers -------               inches     mm            inches       mm

Minimum Quantity ...      1,000              100                  ...................................................

Top          Low       1377G1-BK             1377G1               0.59       14.80         1.52         38.60                                                         A                                                   [ 9.9 ]

             High      1317G1-BK             1317G1                                                                                                                                                                                                   0.39

Bottom       Low       1377G2-BK             1377G2               0.29       7.20          1.36         34.50

             High      1317G2-BK             1317G2                                                                                                                                                                               B

Top          Low       1377G11-BK            1377G11              0.59       14.80         1.21         30.70

             High      1317G11-BK            1317G11                                                                                                                                 Use mounting staples with right angle contacts

Bottom       Low       1377G12-BK            1377G12              0.29       7.20          1.01         25.70                                            (see accessories).

             High      1317G12-BK            1317G12                               

                                                                                                                                                                                            See website for PCB layout drawing.

25A Vertical PCB Contacts Tin Plated

For mating with wire contacts only.          Suitable for vertical applications                 up  to  25A  per          pole,

tin plating enhances solderability.

                                                                                Dimensions

Mating                 Loose Piece                                      -A-

Force      ---------------- Part Numbers ---------------          inches  mm

Minimum Quantity ....     1,000              100                  .......................                                                                    [ 3.1 ]

Low                  1377G3-BK               1377G3               2.22    56.40                                                                              0.12                                     A

High                 1317G3-BK               1317G3               2.22    56.40                                                                          Housing end

Low                  1377G4-BK               1377G4               1.76    44.70

High                 1317G4-BK               1317G4               1.76    44.70

Low                  1377G13-BK              1377G13              1.17    29.70

High                 1317G13-BK              1317G13              1.17    29.70                                                                                                                          [ 36.5 ]

                                                                                                                                                                                                            1.44
45A Right Angle and Vertical PCB Contacts Tin Plated                                                                                                                                                            [ 28.6 ]

Suitable for right angle or vertical applications up to 45A per pole. Tin plating                                                                                                            [ 5.8 ]            1.13

enhances solderability. Right angle contacts cannot be mixed with 25A PCB                                                               Vertical                                             0.23                         [ 16.3 ]

contacts. For mating with wire contacts only.                                                                                                                                                                                0.64

                                                Loose Piece                                                 [ 29.7 ]                                                                                                  PP15/45 Housings

Description                           ----------- Part Numbers -----------                                             1.17             [ 5.1 ]                                                                       (1327 Series)

Minimum Quantity       .............  1,000                  100  ....................                                 REF              0.20                                                                    Right Angle Contact

                                                                                                                                                                                                                Horizontal (bottom)

Vertical                              3-5911P1               1335G1                                                    [ 7.9 ]                               [ 7.9 ]                                            Cat.No. 1336G1

Right Angle Bottom Row                3-5912P1               1336G1                                                    0.31                                  0.31                            Right Angle Contact

Right Angle Top Row                   3-5913P1               1337G1                                                       TYP                                TYP                             Horizontal (top), Cat.No. 1337G1

                                                                                                                          Use mounting  staples with  right  angle contacts (see accessories).

All Data Subject To Change Without Notice                                                                                                                                                    www.andersonpower.com                      - 21 -
                                  45A Premate Ground PCB Contacts

                                  Right angle contacts are suitable for power or ground. Use to mate with 45A                                   [ 45.3 ]                     [ 7.9 ]

                                  ground wire contacts. Tin plated contacts are rated up to 1,500 mating cycles.                  [ 14.7 ]       1.78 [ 41.2 ]               0.31 TYP

                                  C         an be u         sed wit         h other 45A PCB connectors in the bottom row.                              0.578                   1.62               [ 8.4 ]

                                                                                                                                                                             0.33 TYP

                                                                        Mating                         Loose Piece                                                           [ 5.6 ]               Pre-mate wire

                                                                        Force             ------- Part Numbers -------                          [ 3.6 ]        0.22            [ 7.9 ] connector

                                  Minimum Quantity     ...................  1000                  100     ....                    0.14          [ 28.1 ]         0.31

                                  PCB, Bottom Row         Low               3-5952P1              1836G1                                         1.11                  Mated Pair

                                  | PP15-45 ULTRASONICALLY BONDED ASSEMBLIES |

                                  Assemblies feature housings that are ultrasonically welded to create a one piece connector unit using an APP® special process. After welding,

           Powerpole® PP15 to 45  retaining pins are no longer required to secure the stacked housings to each other. This allows Powerpole® 15-45 connectors to be used as a

                                  durable one piece connector header.       Contact customer service for configurations not shown below.

                                  Single Row 1x2 Assemblies                                                                       

SECTION 2                                                                                                                     Housings with     Housings with                               

                                                                                                                              45A Vertical      45A Right Angle                      Color & Type

                                  Circuit Description                                    Housings Only          PCB Contacts      PCB Contacts                         Position Matrix

                                  Minimum Quantity     ................................           500               500                    500            .....           1               2               

                                  DC 2 Wire Standard Housings                            ASMPP30-1X2-RK         ASMPV45-1X2-RK    ASMPR45-1X2-RK                 RED / STD          BLK / STD

                                  DC 2 Wire Reverse Standard Housings                    ASMPP30-1X2-KR         ASMPV45-1X2-KR    ASMPR45-1X2-KR                 BLK / STD          RED / STD

                                  DC 2 Wire Finger Proof                                 ASMFP30-1X2-RK         ASMFV45-1X2-RK    ASMFR45-1X2-RK                 RED / FP           BLK / FP

                                  DC 2 Wire Finger Proof Reverse                         ASMFP30-1X2-KR         ASMFV45-1X2-KR    ASMFR45-1X2-KR                 BLK / FP           RED / FP

                                                                                         

                                  Single Row 1x3 Assemblies

                                                                                                                              Housings with     Housings with

                                                                                                                              45A Vertical      45A Right Angle                            Color & Type

                                  Circuit Description                                    Housings Only          PCB Contacts      PCB Contacts                               Position Matrix

                                  Minimum Quantity     ................................           500               500                    500            .....        1                     2             3

                                  DC 2 Wire Finger Proof with Ground                     ASMFP30-1X3-KER            N/A           ASMFR45-1X3-KER                BLK / FP           GRN / GND   RED / FP

                                  AC Single Phase Finger Proof                           ASMFP30-1X3-KEW        ASMFV45-1X3-KEW   ASMFR45-1X3-KEW                BLK / FP           GRN / GND   WHT / FP

                                  Two Row 2x1 Assemblies

                                                                                                                              Housings with     Housings with

                                                                                                                              45A Vertical      45A Right Angle                      Color & Type

                                  Circuit Description                                    Housings Only          PCB Contacts      PCB Contacts                         Position Matrix

                                  Minimum Quantity     ................................           500               500                    500            ....         1                  2

                                  DC 2 Wire Finger Proof                                 ASMFP30-2X1-KR         ASMFV45-2X1-KR    ASMFR45-2X1-KR                 BLK / FP           RED / FP               

                                  DC 2 Wire Finger Proof Mate                            ASMFP30-2X1-RK         ASMFV45-2X1-RK    ASMFR45-2X1-RK                 RED / FP           BLK / FP               

                                                                                         

                                  Two Row 2x2 Assemblies

                                                                                                                              Housings with     Housings with                               

                                                                                                                              45A Vertical      45A Right Angle                                                       Color & Type

                                  Circuit Description                                    Housings Only          PCB Contacts      PCB Contacts                                            Position Matrix

                                  Minimum Quantity     ................................           500               500                     500           .....        1               2           3          4

                                  AC 3 Phase, 3 Wire Finger Proof                        ASMFP30-2X2-KRWE           N/A                     N/A                  BLK / FP    RED / FP           WHT / FP      GRN / GND

                                  AC 3 Phase, 3 Wire   Finger Proof Mate                 ASMFP30-2X2-WEKR       ASMFV45-2X2-WEKR  ASMFR45-2X2-WEKR               WHT / FP    GRN / GND          BLK / FP      RED / FP

                                  1         2                                            1                2     3                          1                                           1        2

                                  Single Row 1x2 Assembly                                Single Row 1x3 Assembly                           2                                           3        4

                                                                                                                                  Two Row 2x1 Assembly                       Two Row 2x2 Assembly

                                  Type

                                  STD = Standard Housing                                 Hood Up

                                  FP = Finger Proof Housing

                                  GND = Ground Housing

- 22 -                            www.andersonpower.com                                                                                                                      All Data Subject To Change Without Notice
Powerpole® Pak                                  Connectors

- PP15 to PP45                                                                                   Powerpole®             Pak                         connector   shells         enclose                   stacked

                                                                                                 groupings of PP15-45 sized housings in a durable black

                                                                                                 shell for a finished connector appearance and additional

                        Plug shell                                                               features. Inline, panel mount, and blindmate configurations

                        with latch                                                               are available. Plug shells offer the option of integral latches

                                                                                                 and strain relief to help secure your connection.

Snap-in

                                                                                                 • Package Groupings of PP15-45 Connectors

                                                                                                      Provides a finished appearance while protecting the individual

                                                      Blindmate                                       connectors with an outer shell

                                                                                                 • Inline, Panel Mount, “T” or Blindmate Configurations

               T-Pak                                                                                  Allows one connection system to meet multiple needs                                                         Powerpole® Pak  SECTION 2

                                Plug shell

                                without latch                                                    • Optional Latching and Strain Relief

                                                                                                      Secures your connection and wires

For environmentally sealed connector shells to hold Powerpole®

15-180 connectors, see APP®’s SPEC Pak® product series on our

website, www.andersonpower.com

| Powerpole® Pak ORDERING INFORMATION                                                                   |    Powerpole® housings and contacts are sold                         separately.

                                                                                                             See page 20 for ordering information.

Plug Shell without Latch

Can mate inline with other plug shells with or without latches, or mate to a panel

mount receptacle. For use with Powerpole® wire connectors only. Cable Clamp                                                                                                                   [ 53.09 ]

and Hardware Pak or Retaining Pins must be ordered separately.                                                                                                  [ 21.59 ]                     2.09

                                                                                                     Dimensions                                                                                             0.85

                                                                                                             -A-

Description           -------------- Part Numbers --------------  inches       mm                                                                                                                           A

Minimum Quantity   ...  1,000              500        25          .............................                                                     [ 49.28 ]

Black, 2-4 Poles      1461G1-BK             -         1461G1      1.24         31.50                                                                      1.94                 Retaining Pin

Black, 5-6 Poles        -                  1461G2-BK  1461G2      1.56         39.62

Black, 7-8 Poles        -                  1461G3-BK  1461G3      1.87         47.50                                                                Side View                  Top View

                                                                                                                                                    NOTE: Retaining pins are used to secure and position

                                                                                                                                                    Powerpoles® in one of three positions in plug shells.

                                                                                                                                                    Max wire O.D. for 2-4 pole plug shells    is 0.60 inches   [15.2mm²].

Plug Shell with Latch                                                                                                                               For all other plug shells is 0.63 inches  [ 16.0 mm²].

Can mate inline with other plug shells without latches, or mate to a panel mount receptacle. For use

with Powerpole® wire connectors only.      Cable Clamp and Hardware Pak or Retaining Pins must

be ordered seperately.                                                                                                                                         Side View

                                                                                                                                                  Dimensions

                                                                                                                          -B-                            -C-               -D-                              [ 21.59 ]

Description                         ------------- Part Numbers --------------   inches  mm          inches     mm          inches  mm                             0.85

Minimum Quantity   ..... 1,000             500                      25          ................................................................................                        B

Black, 2-4 Poles      1460G1-BK            -                 1460G1             1.94    49.28       2.25       57.15       1.24    31.50

Black, 5-6 Poles        -                  1460G2-BK                 1460G2     1.94    49.28       2.25       57.15       1.56    39.62                                     Top View

Black, 7-8 Poles        -                  1460G3-BK                 1460G3     1.94    49.28       2.25       57.15       1.87    47.50                                                C

Black, 9-10 Poles       -                  1460G4-BK                 1460G4     2.51    63.75       2.82       71.63       1.84    46.74

                                                                                                                                                                                              D

                                                                                                                                                                Retaining Pin

All Data Subject To Change Without Notice                                                                                                                       www.andersonpower.com                             - 23     -
                           Snap-in Receptacle Shell

                           Mate to plug shells without latches, or mate to another panel mount receptacle to create a bulkhead to

                           bulkhead connection. For use with Powerpole® wire or PCB connectors.                    Order the number of retaining pins for

                           each receptacle as shown below separately.                                                                                                                                   [ 1.78 ]
                                                       
                                                                                                                                           Number of                 Dimensions     Knock Out Size                                                                  [ 19.56 ]
                                                                                                                                                                                         [ 27.94 ]      0.07
                                                                                                                                                                                                                                 0.77
                                                                                                                                           Retaining Pins            -E-            - Width -                               1.10

                           Description        ---------------- Part Numbers ----------------            to Order                  inches  mm     inches  mm

                           Minimum Quantity   ...     1,000                 500                     25  ...............................................................................                 E

                           Black, 2-4 Poles     1470G1-BK                           -        1470G1     1                         1.50    38.10  1.25    31.75

                           Black, 5-6 Poles           -                1470G2-BK             1470G2     2                         1.88    47.75  1.62    41.15                                                    Retaining Pin

                           Black, 7-8 Poles           -                1470G3-BK             1470G3     3                         2.13    54.10  1.88    47.75

                           Black, 9-10 Poles          -                1470G4-BK             1470G4     4                         2.44    61.98  2.19    55.63

                           * Height = [25.4 mm] 1.0 in.                                                                                                                                                      NOTE: Retaining pins are used to secure and position

                                                                                                                                                            Powerpoles® in one of two positions in receptacle shells.

           Powerpole® Pak  Cable Clamp & Hardware Pak                                                                                                                                                             Retaining Pin

SECTION 2                  Includes cable clamp, 2 screws, and required amount of retaining pins for each configuration.

                                          Screw Head         Cable                                                                                                                       Cable Clamp

                           Description    Type               Type                         ------------ Part Numbers ------------                                                         With Screws

                           Minimum Quantity   ....................................        1,000         500        25 ...

                           2-4 Poles      Straight Slot      Bundled                      115G1-BK      -         115G1                                Plug Shell Without Latch Shown

                           5-6 Poles      Straight Slot      Bundled                      115G2-BK      -         115G2

                           7-8 Poles      Straight Slot      Bundled                      115G3-BK      -         115G3                                Shell, housing and contacts

                           9-10 Poles     Straight Slot      Bundled                      -             115G4-BK  115G4                                              are sold separately.

                           2-4 Poles      Philips            Bundled                      115G7-BK      -         115G7

                           5-6 Poles      Philips            Bundled                      115G8-BK      -         115G8

                           Flexible Conduit Clamp & Hardware Pak                                                                                                                                                                 Retaining Pin

                           Includes cable clamp, 2 screws, and need amount of retaining pins for each configuration.

                           Description        Part Number

                           Minimum Quantity   ...... 100     ......                                                                                                                                    Conduit Clamp

                           2-4 Poles               110G10                                                                                                                                With Screws

                                                                                                                                                       Plug Shell With Latch Shown

                                                                                                                                                       Shell, housing and contacts

                                                                                                                                                       are sold separately.

                           Retaining Pin for Snap-in Receptacle

                           Order the number of retaining pins for each receptacle shown in the Snap-in Receptacle

                           Shell ordering information. Pins are also required for the plug side when the Cable Clamp &

                           Hardware Pak is not ordered.

                           Description        ------ Part Number -------

                           Minimum Quantity   ......  1,000            100          ....

                           Retaining Pin           110G9-BK  110G9                                                                                                                                     Shell and housing are sold separately.

- 24 -                     www.andersonpower.com                                                                                                                                                      All Data Subject To Change Without Notice
Blindmate Pak Connector                                                                                                                   [ 88.6 ]

Ideal for panel to panel, bulkhead to bulkhead, or rack mount applications that require the                                      [ 76.4 ] 3.49        [ 50.8 ]      [ 36.7 ]           [ 58.93 ]        [ 24.38 ]

power connector to compensate for up to 0.45 in. [11.43 mm] of misalignment in either axis.                                       3.01                    2.00            1.45             2.320          0.960

Eight positions can be filled with Powerpole® 10-45 connectors. The receptacle side can be

used with wire or PCB contacts.   Hardware bag includes retaining pins.

Description                                                              ---------- Part Numbers ----------

Minimum Quantity   ....................................................            50          25      ..........        [ 5.0 ]                                          [ 3.05 ]         [47.24]      [ 13.46 ]

2x4 Blindmate Plug Shell, Hardware & Pins                                          -           BMPP10-45P             Ø    0.20    4            [ 38.6 ]                     0.120         1.860        0.530

                                                                                                                                                1.52

2x4 Blindmate Receptacle Shell, Hardware & Pins                                    -           BMPP10-45R

2x4 Blindmate Plug Shell                                                 BMHSG-P               -                                  Plug Outline                                      Receptacle Outline

2x4 Blindmate Receptacle Shell                                           BMHSG-R               -

Hardware Bag Plug Side                                                             -           110G50                                                                                 [ 29.14 ]

Hardware Bag Receptacle Side                                                       -           110G51                    [ 30.2 ]                                                      1.147

                                                                                                                           1.19

                                                                                                                                          [21.5]                 [  36.7  ]                               [ 0.64 ]     Powerpole® Pak  SECTION 2

                                                                                                                                          0.85                      1.45                                  0.025

                                                                                                                                   [4.4]                                        [ 0.64 ]

                                                                                                                                   0.17                                             0.025

See  APP®’s  innovative          MARC            Connector               that          offers  straight-on   or    rotational     blindmate         capability.

MARC holds 6 PP15/45 power contacts and 2 PP15/45 premate ground contacts in a high temperature

housing.     Visit our website, www.andersonpower.com to learn more.

“T” Pak 2 Way Splitter

The Powerpole® “T” Pak connector is a 2 way electrical splitter that splits electrical current from

one incoming circuit into two outgoing circuits. The standard configuration is pre-wired for AC

3 phase, 3 wire plus ground configurations. The “T” Pak can also be used for AC single phase

plus ground or DC 2 wire plus ground applications by not using either the red or white power

positions. “T” Pak is pre-wired from the factory allowing plug and play field installation

of modular office and industrial equipment. UL recognition up to 20 amps and 600 volts is

achieved when mating Powerpole® Pak plugs are used with #12 AWG wire.

For OEM manufacturing scale applications, the “T” Pak can be loaded with custom                                                                                                               [ 86.2 ]

configurations of any of APP®’s finger proof, standard, or ground housings and contacts                                               [ 102.2 ]                                                  3.39

i         n the          PP15-45 series. Contact APP® sales or customer service for additional information.                                             4.03

Description                                      - Part Numbers -                                                                                                                                   [ 85.8 ]

Minimum Quantity   ............................  80                      ........                                                                                                                   3.38

Assembled “T” Pak                                20-01

Mating Plug Shell with Latch 2x2                 26-01                                                                                                                                [ 53 ]

Mating Plug Shell without Latch 2x2              27-01                                                                                                                                2.09

Standard configuration for each side of the T includes (1) each Red, Black, and White Standard                                            [ 43.2 ]

PP 15-45 Housings & 261G2-LPBK contacts with (1)                         45A Green Premate Ground Housing and                             1.70

1830G1-LPBK contact.                                                                                                                                                         [ 51.1 ]

                                                                                                                                                                                2.01

               

Mating plug shells include (1) each Red, Black, and White Standard PP 15-45 Housings &

(3) 261G2-LPBK contacts with (1)           45A Green Premate Ground Housing and 1830G1-LPBK

contact. Cable clamp & hardware pak also included.

                          A

                                                                                                             27 - 01                                                         26 - 01

                                                                                                             Mates With B                                                    Mates With A & C

                              B                                                        C

All Data Subject To Change Without Notice                                                                                                                           www.andersonpower.com                           -  25  -
                                     | PP15-45 & POWERPOLE® PAK SPECIFICATIONS |

                                     Electrical                                                                           Mechanical               

                                     Current Rating Amperes¹                            UL 1977    CSA/TUV  Wire Size Range                                    AWG                                 mm²

                                     Singlepole Wire to Wire (10 AWG)                   55         40                                                          20 to 10                            0.5 to 6.0

                                     Singlepole Ground Wire to Wire or PCB (10 AWG) 45             35                      

                                     3x3 Block Wire to Wire (10 AWG)                    40         27       Max. Wire Insulation Diameter                      in.                                 mm

                                     Singlepole 25A PCB to Wire (12 AWG)                25         -                                                           0.175                               4.450

                                     2x3 Block 25A PCB to Wire (12 AWG)                 25         22 *                    

                                     Singlepole 45A PCB to Wire (10 AWG)                45         40 *     Operating Temperature²                             °F                                  °C

                                     2x3 Block 45A PCB to Wire (10 AWG)                 45         25 *        Powerpole® Housings & Powerpole® Pak Shells     -4° to 221°                         -20° to 105°

                                                                                                                                         

                                     Voltage Rating AC/DC                                                                 Mating Cycles No Load by Plating                   Silver (Ag)                         Tin (Sn)

                                     UL 1977                                            600                    PCB to Wire                                     -                                   1,500

                                                                                                                             Wire to Wire                                    10,000                              1,500

           Powerpole® PP15 to 45     PCB Connector Recommended Voltage³                                                    

                                     per IEC 60950-1 Table 2L Pollution Degree2                             Avg. Mating / Unmating Force                       Lbf.                                N

                                     25A Contacts Adjacent Poles                        495                    Low Force Wire, High Force PCB, & Ground        3                                   13

                                     25A Contacts Separated by Spacer                   1,000                  High Force Wire                                 5                                   22

                                     45A Contacts Adjacent Poles                        160                    Low Force PCB                                   2                                   9

SECTION 2                            45A Contacts Separated by Spacer                   970                                

                                                                                                                          Min. Contact / Spring Retention Force              Lbf.                                N

                                     Dielectric Withstanding Voltage                                                                                           20                                  90

                                     Volts AC                                           2,200                              

                                                                                                                          Powerpole® Pak Latch Avg. Defeat Force             Lbf.                                N

                                     Avg. Mated Contact Resistance Milliohms¹                                                                                  150                                 667

                                     15A Wire Contact with 5/8” of #16 AWG              0.875                              

                                     30A Wire Contact with 5/8” of #12 AWG              0.600               PCB Specifications               

                                     45A Wire Contact with 5/8” of #10 AWG              0.525                  Mounting Style                                  Plated Through Hole

                                     45A PCB Contact to Contact                         0.500                  PCB Thickness- in. [mm]                         0.090 - 0.150                       (2.3-3.8)

                                     25A PCB Contact to Contact                         0.600                  25A PCB Recommended Traces                      #12 AWG Cross Section

                                                                                                                             45A PCB Recommended Traces                      #10 AWG Cross Section

                                     UL Hot Plug Current Rating Amperes                                                    

                                     250 cycles at 72V DC                               45A                 Min. Creepage / Clearance Distance PCB             in.                                 mm

                                     250 cycles at 120V DC                              30A                    25A Creepage & Clearance Adjacent Poles         0.201                               5.1

                                                                                                                             45A Creepage & Clearance Adjacent Poles         0.067                               1.7

                                     UL Ground Short Time Current Test - 45A Premate Ground

                                     750 Amps, #10 AWG Wire                             4 Seconds              Protection

                                     470 Amps, #12 AWG Wire                             4 Seconds              Touch Safety with Finger Proof Housings & Wire

                                                                                                               Contacts or PCB Mating Interface

                                     Materials                                                                 UL1977 Sec. 10.2   Pass

                                     Housing                                                                   IEC 60950          Pass

                                     Plastic Resin                     Polycarbonate                           IEC 60529          IP20

                                     Contact Retention Spring          Stainless Steel

                                                                                                               Touch Safety Standard Housings

                                     Housing Flammability Rating                                               IEC 60529          IP10

                                     UL94                              V-0

                                     Contact                                                                * No TUV Recognition

                                     Base                              Copper Alloy                         1 Based on: 105°C rated or better cable of the largest size, Properly calibrated APP®

                                     Plating                           Tin or Silver                           recommended tooling, and a 25°C ambient temperature. UL rating not to exceed the

                                                                                                               maximum operating temperature. CSA rating below a 30°C temperature rise.

                                     Contact Termination Methods                                            2  Limited by the thermal properties of the connector plastic housing.

                                     Crimp³                            Wire Contacts                        3  Use APP® recommended tooling only. Alternate tools may adversely affect the

                                     Hand Solder                       Wire and PCB Contacts                   performance of our connectors along with UL and CSA recognition.

                                     Solder Dip                        PCB Contacts

                                     Wave Solder                       PCB Contacts

-          26                     -  www.andersonpower.com                                                                                                          All Data Subject To Change Without Notice
|                 PP15-45 TEMPERATURE CHARTS |

                                PP15-45 Singlepole                                                             PP15-45 Multipole                                                         PP25 PCB

                            Temperature Rise at Constant        Current                                Temperature Rise at Constant Current                                  Temperature Rise at Constant Current

                  60                                                                           60                                                                    60

                  50                                                                           50                                                                    50

Temperature (°C)  40                                                         Temperature (°C)  40                                                  Temperature (°C)  40

                  30                                                                           30                                                                    30

                  20                                                                           20                                                                    20

                  10                                                                           10                                                                    10

                      0                                                                        0                                                                     0

                         0  10          20      30      40      50       60                         0      10          20           30       40                           0  5  10       15  20    25     30   35  40       Powerpole® PP15 to 45  SECTION 2

                                        Amperes Applied                                                            Amperes Applied                                                       Amperes Applied

                            10 AWG              12 AWG          14 AWG                                 10 AWG          12 AWG           14 AWG                               Singlepole      2-Pole           Multipole

                            16 AWG              18 AWG          20 AWG                                 16 AWG          18 AWG           20 AWG

                                PP15-45 Singlepole                                                             PP15-45 Multipole                                                         PP25 PCB

                  125       Derating vs. Ambient Temperature                                   125     Derating vs. Ambient Temperature                                      Derating vs. Ambient Temperature

                                                                                                                                                                     125

Temperature (°C)  100                                                        Temperature (°C)  100                                                 Temperature (°C)  100

                  75                                                                           75                                                                    75

                  50                                                                           50                                                                    50

                  25                                                                           25                                                                    25

                         0  10  20          30      40      50  60       70                         0      10      20      30       40       50                           0  5  10       15  20   25      30  35   40

                                        Amperes Applied                                                            Amperes Applied                                                       Amperes Applied

                            10 AWG              12 AWG          14 AWG                                 10 AWG          12 AWG           14 AWG                               Singlepole      2-Pole           Multipole

                            16 AWG              18 AWG          20 AWG                                 16 AWG          18 AWG           20 AWG

                                        PP45 PCB                                                                   PP45 PCB

                            Temperature Rise at Constant    Current                            125     Derating vs. Ambient Temperature

                  60

                  50

Temperature (°C)                                                             Temperature (°C)  100

                  40

                  30                                                                           75

                  20

                                                                                               50

                  10

                  0                                                                            25

                         0  10  20          30          40      50       60                         0  10      20  30      40  50       60   70

                                        Amperes Applied                                                            Amperes Applied

                            Singlepole          2-Pole          Multipole                              Singlepole      2-Pole           Multipole

NOTE: Temperature rise charts are based on a 25°C ambient temperature.                                         PP25 PCB charts based on 0.002 in² foil on board side,           mated    to  #12  AWG  conductor   on

wire side.                  PP45 PCB charts based on #10 AWG equivalent copper foil on board side, mated to #10 AWG conductor on wire side.

All Data Subject To Change Without Notice                                                                                                                                       www.andersonpower.com                    -  27  -
                                  | Powerpole® 15-45 Accessories |

                                  Mounting Wing

                                  Secure dovetailed Powerpole® 15-45 series housings by passing fasteners through the wings

                                  in either a horizontal or vertical orientation. Useful for sheet metal panels, printed circuit boards,

                                  and many other mounting surfaces. Fasteners not included.                                         

                                  Description              ------- Part Numbers -------                                                                                                                                   Mounting Wings

                                  Minimum Quantity    ...    2,500              100  ....                                                                                            [ 4.6 ]

                                  Red                      1399G9-BK     1399G9                                                                                                      0.180

                                  Blue                     1399G8-BK     1399G8                                                                                                            [ 7.9 ]

                                                                                                                                                                                           0.312

                                                                                                                                                                       [ 16.6 ]

                                                                                                                                                                       0.655

           Powerpole® PP15 to 45  Spacer

                                  Used to separate housings under high power to minimize derating. They are

                                  recommended for squaring off a block of Powerpole® 15-45 housings for use in connector shells

SECTION 2                         and mounting clamps. Use a combination of long and short spacers opposite eachother in a

                                  mated block to add keying features or use two short spacers to avoid interference. Spacers with

                                  holes can also be used to fasten the blocked housings to a surface with a fastener.

                                  Description                ------ Part Numbers -------

                                  Minimum Quantity    .....  2,500              100      .....

                                  Red, Short w/ Hole         1399G1-BK          1399G1                                                                                                                                          [ 7.9 ]

                                  Red, Long                  1399G2-BK          1399G2                                                    [ 7.9 ]                                                   [ 7.9 ]                     0.312

                                  Red, Short                 1399G6-BK          1399G6                                                    0.312                                                     0.312

                                  Black, Long                1399G10-BK         1399G10                      [ 16.6 ]                                                            [ 16.6 ]                       [ 24.6 ]

                                  Blue, Short                1399G13-BK         1399G13                      0.655                                                               0.655                          0.968

                                  White, Short w/ Hole       1399G14-BK         1399G14                                 Short with Hole                                                    Short without Hole             Long

                                  White, Long                1399G17-BK         1399G17

                                  Retaining Pins

                                  Keep stacked Powerpole® 15-45 series housings from separating. Retaining pins are inserted in

                                  the circular opening between two housings stacked side by side.

                                                                                                                                                      Dimensions

                                                                                                                            -A-                     -B-

                                  Description                         ----- Part Numbers -----         inches                           mm                               inches  mm

                                  Minimum Quantity ...       1,000              100      ............................................................................

                                  1 Block High                                  H1507P38                    110G16          0.094                                        2.390                              0.250   6.350

                                  2 Block High                                  111812P5                    110G17          0.099 / 0.106                0.251 / 2.69                  0.440   11.180

                                                                                                                                                                                                    B

                                                                                                                                                                                                                      A

                                  Mounting Clamp

                                  Mounting clamps can be used for fastening a block of Powerpole® 15-45 series

                                  housings to a panel. Connector blocks must be a complete square for the clamps

                                  to work properly. Fastening hardware not included.

                                  Description              -- Part Numbers --

                                  Minimum Quantity    ... 100 sets of 2  .....

                                  2 or 4 Pole                1462G1

                                  3 or 6 Pole                1462G2

                                  4 or 8 Pole                1462G3                                                                                                              2 or      4 Pole   3  or    6  Pole      4 or 8 Pole

- 28 -                            www.andersonpower.com                                                                                                                                                All Data Subject   To Change Without Notice
PCB Mounting Staples

PCB staples are soldered into place to secure Powerpole® 15-45 series housings

in a horizontal configuration to the board. Reduce strain on soldering joints during

mating and unmating.

                                                                           Dimensions

Part                                                                  -A-                -B-

Numbers        HxW         Length          inches     mm    inches       mm

Minimum Quantity    100       ................................................................................

114555P1       1x1         Short           0.47       12.0  0.28         7.0                                                   A

114555P2       1x2         Short           0.47       12.0  0.57         14.5

114555P11      1x2         Long            0.67       17.0  0.57         14.5

114555P3       1x3         Short           0.47       12.0  0.89         22.5

114555P7       1x4         Short           0.47       12.0  1.20         30.5

114555P12      1x4         Long            0.67       17.0  1.20         30.5                                                               B

114555P8       1x6         Short           0.47       12.0  1.83         46.5                                                                                        Powerpole® PP15 to 45  SECTION 2

114555P13      2x2         Long            0.91       23.0  1.83         46.5

114555P10      2x1         Short           0.79       20.0  0.28         7.0

114555P6       2x2         Short           0.79       20.0  0.57         14.5

114555P9       5x2         Long            0.91       23.0  0.57         14.5

114555P14      2x5         Long            0.91       23.0  1.52         38.5

114555P4       3x2         Short           1.10       28.0  0.57         14.5

                       

Retention Clip

Retention clips prevent Powerpole® 15-45 blocks from unintended disconnects.

They feature a tab for easy insertion and removal.

Description           -- Part Number --

Minimum Quantity ........     100     .........                       

1 Block High                  110G68

               

Block Lok

Block locks secure mated Powerpole® 15-45 series housings together. For use in

h         igh vibration or sh         ock applications where connectors are unmated infrequently.

Description           - Part Numbers -

Minimum Quantity ..........      100  .........                                                                        2 Pole                  4 Pole

2 Pole, Black                 110G21                                                                                          Shown  without Powerpoles®  Shown with  Powerpoles®

4 Pole, Black                 110G12

               

Splash Boot

Splash boots protect a 2x2 block of any combination of Powerpole® 15-45 series

housings and feature snip off sealed ends for flexibility in wire O.D. Designed for

through panel or inline applications. Not a hermetic seal.

Description           - Part Numbers -

Minimum Quantity    ........  25   ...........

Female, Black                 1441G1

Male, Black                   1442G1

For environmentally sealed connector shells to hold Powerpole®

15-180 connectors, see APP®’s SPEC Pak® product series on our

website, www.andersonpower.com

All Data Subject To Change Without Notice                                                                                                   www.andersonpower.com    - 29 -
                            Powerpole® Connectors

                            - PP75: up to 120 Amps

                                                                                                       PP75 series Powerpole® housings can be used for wire-to-wire,

                                                                                                       wire-to-board,      and       wire-to-busbar             applications.  Wire      sizes

                                                                                                       from  #16  AWG      (1.3      mm²)   to        #6  (13.3  mm²)          offer     power

                                                                                                       capabilities up to 120 amps per pole. Locking housings offer

                                                                                                       the capability to secure Powerpole® housings to each other

                                                                                                       and   to  mounting            pads.  Housings            made  from     chemical

                                            PP75 with                                                  resistant (CR) resin withstand industrial solvents better than

                                            Mounting Wings                                             standard housings.

                                                                                                       • Large Wire Range Accommodates up to #6 (10mm²) Wire

                                                                                                       Reducing bushings allow as small as #16 (1.5 mm²) wire to be used

           Powerpole® PP75                                                                             • Wire, PCB, and Busbar Contacts

                                                                                                       Allows one connection system to meet multiple needs

SECTION 2                                                                                              • Mini-Powerclaw PCB Contacts Minimize PCB Footprint

                                                                                                       Removes the PP75 housing from the board side

                               | PP75 ORDERING INFORMATION |

                               PP75 Standard Housings               

                               The second smallest Powerpole® housing can be used with wire  contacts

                               for up to 6 AWG [10mm²]  as well as PCB and busbar contacts.

                               Description            ------- Part Numbers --------

                               Minimum Quantity  ...    1,000            100  ......

                               Red                    5916G7-BK      5916G7

                               Green                  5916G6-BK      5916G6                                      [ 15.9 ]

                               Black                  5916G4-BK      5916G4                                      0.62                       [ 47.9 ]

                               White                  5916G5-BK      5916G5                                                                 1.88

                               Blue                   5916-BK        5916                                                  [ 15.9 ]                                            [ 17.0 ]

                               Yellow                 5916G15-BK     5916G15                                               0.62                                                0.67

                               Orange                 5916G14-BK     5916G14                                                                          [ 81.3 ]

                               Gray                   5916G16-BK     5916G16                                                                          3.20

                                                                                                             Front View              Mated  Length

                                              

                               PP75 Chemical Resistant (CR) Housings               

                               Has the same form and dimensions of the standard

                               PP75 housing in a chemical resistant PBT/ PC blend

                               housing.  Suitable for use to -40°C.

                               Description             - Part Numbers -                                                                     Material ID         V0 = Standard

                               Minimum Quantity  ...    1,000        .......                                                                Located Here        P = Chemical Resistant

                               Red                     P5916G7-BK

                               Black                   P5916G4-BK

                               White                   P5916G5-BK

                               Blue                    P5916-BK

                                              

-          30               -        www.andersonpower.com                                                                                                  All Data Subject To Change Without Notice
PP75 Locking Dovetail Housings               

Offers dovetails for stacking housings that have a locking feature to prevent housings separating.

Can mate to standard and chemical resistant housings, but cannot be stacked with them.

Description                 ---------- Part Numbers -----------

Minimum Quantity     ....         1,000                    100  .....

Red                         75LOKRED-BK               75LOKRED

Green                       75LOKGRN-BK               75LOKGRN

Black                       75LOKBLK-BK               75LOKBLK

White                       75LOKWHT-BK               75LOKWHT                                                                                                                [ 47.9 ]

Blue                        75LOKBLU-BK               75LOKBLU                                                                                                                1.88

Gray                        75LOKGRA-BK               75LOKGRA

PP75 Silver Plated Wire Contacts                                                                                                                                                                                    Powerpole® PP75  SECTION 2

Silver plated contacts offer the best electrical performance and durability up to 10,000 mating cycles.

                                                                                                             Dimensions

                                          Mating             Loose Piece                      -A-

AWG            mm²          Force              -- Part Numbers --         inches  mm

Minimum Quantity     ........................  1,000       100         ........................

6              13.3         Low                1307-BK     1307           0.22    5.59

6              13.3         High               5900-BK     5900           0.22    5.59                                     [ 11.4 ]

8              8.4          High               5952-BK     5952           0.19    4.83                                         0.45                 [ 30.0 ]

12 to 10       3.3 to 5.3   Low                5953-BK     5953           0.14    3.56                                                              1.18

12 to 10       3.3 to 5.3   High               5915-BK     5915           0.14    3.56                                         A

                                                                                                                                                [ 7.2 ]                                                                   [ 7.1 ]

                                                                                                                               0.28                                                                  0.28

PP75 Tin Plated Reeled Wire Contacts

Reeled contacts are for use with the recommended high volume press and applicator tooling.

Tin plating is rated for up to 1,500 mating cycles.           Silver plated or low mating force contacts

may be available for high volume applications.             Inquire with customer service.

                                                    Reeled                                     Dimensions

                                                    Mating          Part                  -A-                -B-

AWG                        mm²               Force           Numbers     inches      mm         inches             mm

Minimum Quantity     .......................   2,000       ........................................................                                                     A

8 to 6                     8.4 to 13.3       High            265G5       0.26        6.60       0.36               9.14

12 to 10     3.3 to 5.3        High            265G6       0.17        4.32       0.29               7.37                                 [ 32.2 ]        B

                                                                                                                                                                      1.27

PP75 Silver Plated Busbar Contacts

Provide a quick disconnect input or output busbar connection. Busbar contacts are

for mating with wire contacts only. Part number 75BBS includes lock nuts. Locknuts                                                        See Busbar contact drawing on                              [ 17.1      ]

m         ust b         e ordered separately for B01956P4.                                                                                              website for further detail.                                      0.68

                                         Mating

Type         Thread        Force        -------------------- Part Numbers --------------------

Minimum Quantity     .................         1,000       120             20                    10  ...                                                            [ 2.0 ]

Busbar       #10-24        High         B01956P4        B01956P4             -        75BBS                                                                             0.08

Lock Nut     #10-24         -           H1216P8            -              110G54                 -                                                            [ 69.1 ]

                                                                                                                                                              2.72

55A Right Angle Standard Powerclaw PCB Contacts                                                                                                                         Second housing

Standard Powerclaw contacts are for use inside a PP75 housing and                                                                                                       and contact in two

provide a color coded right angle connection to the PCB.                                                                                                                pole version only.

Description              --- Loose Piece Part Numbers --                             [ 5.2 ]                                              [ 17.0 ]

Minimum Quantity     .....     500                    100  ........                   0.20                                                      0.67

Tin Plated                PC5930T-BK           PC5930T

Silver Plated             PC5930S-BK           PC5930S                               [ 22.2 ]                                                                 [ 32.8 ]

                                                                                     0.87                                                                     1.29

                                                                                                                               [ 48.0  ]

                                               PP75 Housing                                                                    1.89

                                                                                                                     [ 66.0 ]                                           See PCB contact drawing      on

                                                                                                                     2.60                                               website for further detail.

            Standard Powerclaw Contact

All Data Subject To Change Without Notice                                                                                                                     www.andersonpower.com                                 - 31 -
                               55A                    Right Angle Mini Powerclaw PCB Contacts

                               Right angle Mini Powerclaw contacts can be used on the PCB edge

                               without a PP75 housing on the PCB side. A self polarizing design only

                               allow PP75 wire housings to mate to PCB contacts one way.                                                                                        [ 8.1 ]                                         [ 12.19 ]

                                                                                            Loose Piece                                                [ 58.4 ]                               0.32            [ 24.6 ]                             0.480

                               Description                           -------- Part Numbers --------                                          2.30          [ 15.6 ]                                          0.97

                               Minimum Quantity                      ...  1,000            100    ......                                                       0.61      [ 7.6 ]

                                                                                                                                                                         0.30

                               Tin Plated                                               PC5934T-BK       PC5934T                                                                       [ 2.42 ]                                                             [ 25.4 ]

                               Silver Plated                                            PC5934S-BK       PC5934S                                                                          0.095                                     [ 17.5 ]                1.00

                                                                                                                                                                                [ 6.10 ]                              0.69                        [ 1.27 ]

                                                                                                                                                                                0.240                                                               0.050

                               55A                    Vertical Mini Powerclaw              PCB Contacts

                               Vertical Mini Powerclaw contacts save space by not

                               requiring a PP75 housing on the PCB side. The guide                                                                                                                                                                [ 6.25 ]

                               housing is required for 2 pole applications to provide a                                                                                                                               [ 12.2 ]                    0.246

                               polarized connection.                      (See PP75 accessories).                                                                                                                         0.48

                                                                              Loose Piece                                                                                       [  24.3 ]

           Powerpole® PP75     Description                           --------- Part Numbers -------                                                                                0.96

SECTION 2                      Minimum Quantity ...                       1,500            100    ......                                                                               [ 9.7 ]               [2.32]

                               Tin Plated                            PC5933T-BK           PC5933T                                                                                      0.38                  0.091                                [ 1.27 ]

                               Silver Plated                         PC5933S-BK           PC5933S                                                                                                                                                 0.050

                                                                                                                                                                                                                          [ 10.29 ]           [ 4.98 ]

                                                                                                                                                                                                                          0.405               0.196

                                                                                                                                                                            See    PCB contact drawing on website                        for  further detail.

                            |  PP75 TEMPERATURE CHARTS |

                                                                     PP75 Singlepole                                                         PP75 Multipole                                                                      Mini Powerclaw

                                                 125     Derating vs. Ambient Temperature                                    125     Derating vs. Ambient Temperature                                                 Derating vs. Ambient Temperature

                                                                                                                                                                                                             125

                               Temperature (°C)  100                                                       Temperature (°C)  100                                                           Temperature (°C)  100

                                                 75                                                                          75                                                                              75

                                                 50                                                                          50                                                                              50

                                                 25                                                                          25   0  10  20  30    40  50  60  70    80     90  100                          25

                                                      0      20      40       60      80   100       120                                                                                                           0  10  20    30   40  50   60  70    80     90 100110

                                                                          Amperes Applied                                                        Amperes Applied                                                                     Amperes Applied

                                                                     6 AWG                 8 AWG                                             6 AWG             8 AWG                                                          Singlepole                2-Pole

                                                                     10 AWG           12 AWG                                                 10 AWG            12 AWG

                                                         PP75 Singlepole Loose Piece Contact                                         PP75 Multipole Loose Piece Contact                                                          Mini Powerclaw

                                                 60      Temperature Rise at Constant Current                                        Temperature Rise at Constant Current                                             Temperature Rise at Constant Current

                                                                                                                             60                                                                              60

                                                 50                                                                          50                                                                              50

                               Temperature (°C)  40                                                        Temperature (°C)  40                                                            Temperature (°C)  40

                                                 30                                                                          30                                                                              30

                                                 20                                                                          20                                                                              20

                                                 10                                                                          10                                                                              10

                                                 0                                                                           0                                                                               0

                                                      0  10  20  30  40   50  60  70  80   90 100 110 120                         0  10  20  30        40  50  60    70     80     90                              0  10  20        30   40   50  60        70  80  90

                                                                          Amperes Applied                                                        Amperes Applied                                                                     Amperes Applied

                                                                     6 AWG                8 AWG                                              6 AWG                   8 AWG                                                    Singlepole                2-Pole

                                                                     10 AWG           12 AWG                                                 10 AWG            12 AWG

                               NOTE: Temperature rise charts are based on a 25°C ambient temperature.                                        Powerclaw charts are based on #8 AWG equivalent copper foil on board side, mated to

                               #6 AWG conductor on wire side.

-          32               -                    www.andersonpower.com                                                                                                                                                    All Data Subject To Change Without Notice
| PP75 SPECIFICATIONS |

Electrical                                                                                  Mechanical               

Current Rating Amperes¹                    UL 1977  CSA                       Wire Size Range                        AWG                           mm²

Wire to Wire (6 AWG)                       120      70                                                               16 to 6                       1.3 to 13.3

Wire to PCB (6-AWG)                        55       50                                       

Wire to Busbar (6 AWG)                     75                                               Max. Wire Insulation Diameter          in.                           mm

                                                                                                                     0.437                         11.100

Voltage Rating AC/DC                                                                                       

UL 1977                                    600                                Operating Temperature²                 °F                            °C

                                                                                            Standard                               -4° to 221°                   -20° to 105°

PCB Connector Recommended Voltage 3                                                         Chemical Resistant*                    -40 to 221°                   -40° to 105°

per IEC 60950-1 Table 2L Pollution Degree 2                                                 *Chemical resistant material not available for PCB guide housings               

Mini Vert. Contact Adjacent Poles          220                                               

Mini Horiz. Contact Adjacent Poles         200                                Mating Cycles No Load by Plating       Silver (Ag)                   Tin (Sn)

Standard Contact Adjacent Poles            635                                Wire and PCB Contacts                  10,000                        1,500                 Powerpole® PP75  SECTION 2

                                                                                                           

Dielectric Withstanding Voltage                                                             Avg. Mating / Unmating Force           Lbf.                          N

Volts AC                                   2,200                              Wire to Wire Low Force Contacts        5                             22

                                                                                            Wire to Wire High Force Contacts       7                             31

Avg. Mated Contact Resistance Milliohms¹                                                    Standard Powerclaw to Wire             7                             31

Wire Contact with 1 1/4” of #6 AWG         0.200                              Mini Powerclaw to Wire                 4                             17

PCB Contact to Contact                     0.500                                             

                                                                                            PCB Specifications               

UL Hot Plug Current Rating Amperes - 250 cycles at  120V  DC                  Mounting Style                         Plated Through Hole

Wire- wire                                 50A                                Max PCB Thickness- in. [mm]            Standard: 0.15 [0.381]

PCB- wire (Vertical Mini Powerclaw)        40A                                                                       Mini:    0.25 [0.635]

                                                                              Recommended Traces                     #8 AWG Cross Section

Materials                                                                                    

Housing                                                                       Min. Contact / Spring Retention Force  Lbf.                          N

Standard Plastic Resin       Polycarbonate                                    Wire Housing                           50                            222

Chem. Resistant Resin        Polycarbonate / PBT blend                                       

Contact Retention Spring     Stainless Steel                                  Min. Creepage / Clearance Distance PCB in.                           mm

                                                                              Standard Powerclaw Adjacent Poles      0.260                         6.6

Housing Flammability Rating                                                   Mini Vert. Powerclaw Adjacent Poles    0.087                         2.2

UL94                         V-0                                              Mini Horz. Powerclaw Adjacent Poles    0.079                         2.0

Contact                                                                       Protection

Base                         Copper Alloy                                     Touch Safety with Wire Contacts

Wire Plating                 Silver                                           IEC 60529            IP10

PCB Plating                  Sn or Ag over Ni

Contact Termination Methods

Crimp4                       Wire Contacts

Hand Solder                  Wire and PCB Contacts

Solder Dip*                  PCB Contacts

Wave Solder*                 PCB Contacts

Wrench / Socket              Busbar Contacts

¹ Based on: 105°C rated or better cable of the largest size, Properly calibrated APP® recommended  tooling, and a 25°C ambient temperature. UL rating   not  to  exceed

the maximum operating temperature. CSA rating below a 30°C temperature rise.

² Limited by the thermal properties of the connector plastic housing.

³ Without use of spacers to increase creepage and clearance distances.

4 Use APP® recommended tooling only. Alternate tools may adversely affect the performance of our   connectors along with UL and CSA recognition.

All Data Subject To Change Without Notice                                                                                   www.andersonpower.com                        - 33 -
                            | Powerpole® PP75 Accessories |

                            Strain Relief Grommets

                            Use for strain relief in the back side of a PP75 housing. Wire gauge given for reference

                            only, use grommet ID and wire OD to determine suitability in the end application.

                                                                                     Dimensions

                                                                                                  -A-

                            Description              - Part Numbers -  inches mm

                            Minimum Quantity  ...    100               .......................               

                            #6 AWG, Black            114411P2          0.35        8.89

                            #8 AWG, Black            114411P1          0.25        6.35                                                                            A

                            #10 - 12 AWG, Black      114411P3          0.17        4.32

                            Mounting Wing for Standard or CR Housings

                            Mounting wings can be used to secure dovetailed Powerpole® 75 series housings by

           Powerpole® PP75  passing fasteners through the wings in either a horizontal or vertical orientation. Useful for

                            sheet metal panels, printed circuit boards, and many other mounting surfaces. Fasteners

SECTION 2                   not included.

                                                                                                                                                         [ 27.4 ]                  [ 27.4 ]

                            Description              ------- Part Numbers -------                                                                            1.08                      1.08

                            Minimum Quantity  ...    1,000             100         ...               

                            Blue, Round Hole         1399G20-BK        1399G20                                                                     [ 15.9 ]                  [ 15.9 ]

                            Blue, Oval Hole          1399G7-BK         1399G7                                                                      0.63                      0.63

                                                                                                                                                    [ 15.9 ]                 [ 15.9 ]

                                                                                                                                                    0.63                     0.63

                            Mounting Wing for Locking Housings

                            Mounting wings can be used to secure Powerpole® 75 series housings with locking

                            dovetails by passing fasteners through the wings in either a horizontal or vertical orientation.

                            Useful for sheet metal panels, printed circuit boards, and many other mounting surfaces.

                            Fasteners not included.                                                                           [ 2.6 ]                                        [ 5.1 ]

                            Description                            --------------------- Part Numbers ---------------------                 R  0.10                                        Ø     0.20

                            Minimum Quantity  ...    1,000                               100           ...                                [ 6.9 ]                  [ 15.9 ]

                            Blue, Oval Hole          75LOKWNGBLU-BK                75LOKWNGBLU                                Oval Hole        0.2         7                 0.63                        Round Hole
                                                                                                                                                                 [ 01         .56.39 ]
                            Blue, Round Hole         75LOKWNGBLU-R-BK              75LOKWNGBLU-R                              - Mounting Wing Top                            - Mounting Wing  Top

                                                                                                                                                                             [ 5.1 ]

                                                                                                                                                                             Ø     .20        [ 27.4     ]

                                                                                                                              Left Side View                              Right Side View          1.08

                                                                                                                              - Both Versions                             - Both Versions

                            Surface Mount for Locking Housings                                                                            [ 2.8 ]            [ 15.7 ]

                            Use to secure Powerpole® 75 series housings with locking dovetails to a flat surface.                         0.11               0.62

                            Useful for sheet metal panels, printed circuit boards, and many other mounting surfaces.                                                               [ 43.2 ]   [ 4.9 ]

                            Fasteners not included.                                                                                                          [ 7.9 ]                   1.70   0.19

                            Description            ----------------- Part Numbers ----------------                               [ 3.6 ]                     0.31

                            Minimum Quantity  ...    1,000                         100            ...                            0.14     Top View                           Side View

                            Blue                   75LOKSMTBLU-BK      75LOKSMTBLU               

                                           

                                                                                   

- 34 -                      www.andersonpower.com                                                                                                                         All Data Subject To Change Without Notice
Guide Housings for Vertical Mini Powerclaw Contacts

Prevents polarity being reversed when a two pole PP75 block is mated to

vertical mini Powerclaw contacts.          Fastening hardware not included.

               

Description                               ----------- Part Numbers ------------

Minimum Quantity     ...    1,000                           100            ...                                                                    PP75 Connector

Black Guide Housing         PC-HSG-PP-BK             PC-HSG-PP                                                                                    Mini Vertical

                                                                                                                                                                Powerclaw Contact

                                                                                                                                                       Guide Housing

                                                                                                                                                                 PCB

Mounting Clamp

Mounting clamps can be used for fastening a block of Powerpole® 75 series

housings to a panel. Connector blocks must be a complete square for the

clamps to work properly. Fastening hardware not included.                                                                                                                                                       Powerpole® PP75  SECTION 2

Description          -- Part Numbers --

Minimum Quantity     ...    50 sets of 2   ...

2 or 4 Pole                 1463G1                                                                                               Mounting Clamp

3 or 6 Pole                               1463G2               

                                                                                                              Panel

                                                                                                                                                                      2 Pole      3 Pole

Retaining Pins

Retaining pins are used to keep stacked Powerpole® 75 series housings from separating.

Retaining pins are inserted in the circular opening between two housings stacked side by side.

Dimension B is +/- 0.015 in or 0.38 mm.

                                                                                                              Dimensions

                                                                                              - A -                                -B-

Description               ------ Part Numbers ------        inches                  mm                inches  mm

Minimum Quantity     ...    1,000               100         ................................................................................

1 Block High                111812P7       110G19           0.196 / 0.207           4.98 / 5.26       0.560   14.220

2 Block High                111812P6       110G18           0.196 / 0.207           4.98 / 5.26       1.000   25.400

                                                                                                                                                                                  B

PCB Mounting Staples                                                                                                                                                                      A

Reduce strain on solder joints during mating and unmating. Staples bend over the underside

of the PCB board to lock the housings in place. Staples are an interference fit with housings.

                            Number of

                            Stacked Powerpoles®                                                                                                   Staple

---- Part  Numbers ----     HxW                                                                                Housings

Minimum Quantity     .....  100    .......................

PCSTAPLE-1                  1x1                                                                                                                   PCB

PCSTAPLE-2                  1x2                                                                                                                                                           Fasten the staple by

                                                                                                                                                                                          bending the leads on  the

                                                                                                                                                  Slide staple over housings and          bottom of the board.

Reducing Bushings                                                                                                                                 into the holes in the board.

Use with contact part number 5900-BK or 1307-BK to allow a smaller wire to

be used with the connector. Electrical capability is derated with smaller wire.

                                                                                                                                                                                 Dimensions

                                                                                                                                          - ID -                                   - Length -

Contact Barrel Size         Wire Size                ------------------ Part Numbers ------------      inches                                 mm       Inches    mm

Minimum Quantity     ....................................................  3,000         1,000   100   ........................................................                      ID

#6 AWG [13.3 mm²]           #8 AWG [8.4 mm²]                                    -   5912-BK      5912  0.18       4.57                            0.45         11.43  Length

#6 AWG [13.3 mm²]           #12- 10 AWG [3.3- 5.3 mm²]                     5910-BK       -       5910  0.14       3.56                            0.47         11.94

#6 AWG [13.3 mm²]           #16- 14 AWG [1.3- 2.1 mm²]                     5913-BK       -       5913  0.09       2.29                            0.47         11.94

                                                                                                                                                                                     Wire Entrance

For environmentally sealed connector shells to hold Powerpole®

15-180 connectors, see APP®’s SPEC Pak® product series on our

website, www.andersonpower.com

All Data Subject To Change Without Notice                                                                                                                                       www.andersonpower.com           - 35  -
                             Powerpole® Connectors

                             - PP120: up to 240 Amps

                                                                                                                     PP120               series                      Powerpole®         housings       are    designed

                                                                                                                     to accommodate up to 1/0 (50 mm²) wires and handle

                                                                                                                     high currents up to 240 amps. Reducing bushings allow

                                                                                                                     PP120 to accept down to #8 (10 mm²) wires. Multiple

                                                                                                                     colors of stackable housings combine with APP®’s low

                                                                                                                     resistance                                flat  wiping  technology            to  offer  powerful

                                                                                                                     connection capability.

                                                                                                                     • Large Wire Range Accommodates up to 1/0 (50mm²) Wire

                                                                                                                     Reducing bushings allow as small as #8 (10 mm²) wire to be used

                                                                                                                     • Low Resistance Silver Plated Copper Contacts

           Powerpole® PP120                                                                                          Allows currents up to 240 amps

SECTION 2                                                                                                            • UL Rated for Hot Plugging up to 60 Amps

                                                                                                                     Great for battery or other applications where the ability to

                                                                                                                     interrupt circuits is required

                                | PP120 ORDERING INFORMATION                                             |

                                PP120 Housings               

                                The second to largest Powerpole® housing can be used with

                                wire contacts for up to 1/0 AWG [50mm²] or busbar contacts.

                                Description            -------- Part Numbers --------                                                        [ 22.2 ]

                                Minimum Quantity  ...       500             50       .......                                   0.88                                          [ 69.9 ]

                                Red                    1321G3-BK            1321G3                                                                                                2.75

                                Green                  1321G4-BK            1321G4                                                                             [ 22.2 ]                                       [ 23.7 ]

                                Black                  1321G1-BK            1321G1                                                                             0.88                                           0.93

                                White                  1321G2-BK            1321G2                                                                                                      [ 117.5 ]

                                Blue                   1321-BK              1321                                                                                                        4.63

                                Gray                   1321G8-BK            1321G8

                                PP120 Silver Plated Wire Contacts

                                Silver plated contacts offer superior electrical performance and durability up to 10,000 mating cycles.

                                New contacts for #1 to 1/0 AWG (35 to 50 mm²) offer extended capability in the same housings.

                                                           Mating                                                                                     -A-      -B-

                                AWG    mm²   Force          -------- Loose  Piece Part Numbers --------  inches  mm  inches    mm                       

                                Minimum Quantity  ........  600             500               50         ....................................................

                                1/0    53.5  Low            1323G2-BK             -           1323G2                   0.52                  13.21                 0.44                 11.18

                                1      42.4  Low            1323G1-BK             -           1323G1                   0.47                  11.94                 0.39                 9.91

                                2      33.6  Low                 -                        6811G6-BK         6811G6                   0.44                  11.18                 0.22                 5.59

                                2      33.6  High                -                        1319-BK           1319                     0.44                  11.18                 0.22                 5.59

                                4      21.1  Low                 -                        6811G5-BK         6811G5                   0.44                  11.18                 0.30                 7.62

                                4      21.1  High                -                        1319G4-BK         1319G4                   0.44                  11.18                 0.30                 7.62

                                6      13.3  Low                 -                        6811G4-BK         6811G4                   0.44                  11.18                 0.34                 8.64

                                6      13.3  High                -                        1319G6-BK         1319G6                   0.44                  11.18                 0.34                 8.64

                                                                                                                                         [ 21.3 ]                        [ 50.8 ]

                                                                                                                                         0.84                                2.0

                                                                                                                                         B

                                                                                                                                         A                                                                    [ 10.4 ]

                                                                                                                                                                                                                    0.41

-          36                -       www.andersonpower.com                                                                                                                              All Data Subject To Change Without Notice
|  PP120 SPECIFICATIONS |

   Electrical                                                                                  Mechanical               

   Current Rating Amperes¹                                     UL 1977   CSA     Wire Size Range                                        AWG          mm²

   Singlepole UL 1977 (1/0 AWG)                                240       155                                                            10 to 1/0    5.3 to 53.5

   2x2 Block UL 1977 (1/0 AWG)                                 200       110                    

                                                                                               Max. Wire Insulation Diameter                          in.          mm

   Voltage Rating AC/DC                                                                                                                 0.600        15.240

   UL 1977                                                     600                              

                                                                                               Operating Temperature²                                 °F           °C

   Dielectric Withstanding Voltage                                                                                                      -4° to 221°  -20° to 105°

   Volts AC                                                    2,200                            

                                                                                               Mating Cycles No Load by Plating                       Silver (Ag)

   Avg. Mated Contact Resistance Milliohms¹                                      Wire Contacts                                          10,000

   5 1/2” of #2 AWG wire                                       0.136                            

                                                                                               Avg. Mating / Unmating Force                           Lbf.         N                                Powerpole® PP120  SECTION 2

   UL Hot Plug Current Rating Amperes                                                                                                   8            36

   250 cycles at 120V DC                                       60A                              

                                                                                 Min. Contact / Spring Retention Force Lbf.                          N

                                                                                                                                        60           267

   Materials

   Housing                                                                       Protection

   Plastic Resin                              Polycarbonate                      Touch Safety with Wire Contacts

   Contact Retention Spring                   Stainless Steel                                      IEC 60529      IP10

   Housing Flammability Rating                                        ¹ Based on: 105°C rated or better cable of the largest size, Properly calibrated APP® recommended tooling, and

   UL94                                       V-0                     a 25°C ambient temperature. UL rating not to exceed the maximum operating temperature. CSA rating below

   Contact                                                            a 30°C temperature rise.

   Base                                       Copper Alloy            ² Limited by the thermal properties of the connector plastic housing.

   Plating                                    Silver                  ³ Use APP® recommended tooling only. Alternate tools may adversely affect the performance of our connectors

                                                                      along with UL and CSA recognition.

   Contact Termination Methods

                     Crimp³                   Wire Contacts

                     Hand Solder              Wire Contacts

|  PP120 TEMPERATURE CHARTS                                                   |

                                      PP120 Singlepole                                                            PP120 Multipole

                             Temperature Rise at Constant Current                                         Temperature Rise at Constant Current

                     60                                                                            60

                     50                                                                            50

   Temperature (°C)  40                                                          Temperature (°C)  40

                     30                                                                            30

                     20                                                                            20

                     10                                                                            10

                     0   0        50     100  150         200       250                            0   0      50        100  150        200     250

                                         Amperes Applied                                                               Amperes Applied

                             1/0 AWG          1 AWG            2 AWG                                          1/0 AWG        1 AWG           2 AWG

                                  4 AWG       6 AWG                                                           4 AWG          6 AWG

NOTE: Temperature rise charts are based on a 25°C ambient temperature.

                     Derating charts on the following page.

All Data Subject To Change Without Notice                                                                                                            www.andersonpower.com            - 37 -
                                                           PP120 Singlepole                                                                                            PP120 Multipole

                                                       Derating vs. Ambient Temperature                                                                    Derating vs. Ambient Temperature

                                               125                                                                                              125

                             Temperature (°C)  100                                                                            Temperature (°C)  100

                                               75                                                                                               75

                                               50                                                                                               50

                                               25   0  50  100  150           200         250                   300                             25

                                                                                                                                                     0     50        100             150  200    250  300

                                                                Amperes Applied                                                                                        Amperes Applied

                                                       1/0 AWG             1 AWG          2 AWG                                                            1/0 AWG                        1 AWG  2 AWG

           Powerpole® PP120                            4 AWG               6 AWG                                                                               4 AWG                      6 AWG

SECTION 2                    | Powerpole® PP120 Accessories |

                             Mounting Clamp

                             Mounting clamps can be used for fastening a block of Powerpole® 120 series housings to a

                             panel. Connector blocks must be a complete square for the clamps to work properly. Fastening

                             hardware not included.

                             Description                        - Part Numbers -                                                                          Mounting Clamp

                             Minimum Quantity              ...  20 sets of 2  ......

                             2 Pole                             1464G1

                             3 Pole                             1464G2                                                                                               Panel

                                                                                                                                                                                                           2     Pole               3 Pole

                             Retaining Pins

                             Retaining pins are used to keep stacked Powerpole® 120 series housings from

                             separating. Retaining pins are inserted in the circular opening between two

                             housings stacked side by side. Dimension B is +/- 0.015 in or 0.38 mm.

                                                                                                                                              Dimensions

                                                                                                                                   - A -                                               -B-

                             Description                        ----- Part Numbers -----  inches                         mm                                           inches  mm

                             Minimum Quantity              ...  1,000         100         .........................................................................

                             1 Block High                       111812P7      110G19      0.196 / 0.207                  4.98 / 5.26                                  0.560   14.220

                             2 Block High                       111812P8      110G20      0.196 / 0.207                  4.98 / 5.26                                  1.500   38.100

                                                                                                                                                                                                                         B

                                                                                                                                                                                                                           A

                             Reducing Bushings

                             Use with contact part number 1319-BK or 6811G6-BK to allow a smaller wire to be used

                             with the connector.           Electrical capability is derated with smaller wire.

                                                                                                                                                                                                  Dimensions

                                                                                                                                                                                                        - ID -

                             Contact Barrel Size                Wire Size                                       --------- Part Numbers ---------               inches  mm                                     [  21.4 ]

                             Minimum Quantity              ...................................................  2,000         1,000                  100   ........................                              0.84

                             #2 AWG [33.6 mm²]                  #4 AWG [21.2 mm²]                               5919-BK       -                      5919      0.28    7.11

                             #2 AWG [33.6 mm²]                  #6 AWG [16 mm²]                                      -        5920-BK                5920      0.23    5.84                      ID                                 [ 8.4 ]

                             #2 AWG [33.6 mm²]                  #10 - 8 AWG [5.3 - 8.4 mm²]                     5921-BK                                            5921      0.18    4.57                                                         0.33

                             For environmentally sealed connector shells to hold Powerpole®

                             15-180 connectors, see APP®’s SPEC Pak® product series on our

                             website, www.andersonpower.com

- 38 -                                         www.andersonpower.com                                                                                                                                             All Data  Subject  To Change  Without  Notice
Powerpole®                          Connectors

- PP180: up                         to 350 Amps

                                                                                             PP180 are the largest of the Powerpole® series housings.

                                                                                             They are designed to accommodate up to 3/0 (70 mm²)

                                                                                             wires and handle high currents up to 350 amps. Busbar

                                                                                             contacts are also available for power inputs and takeoffs.

                                                                                             Color-coded housings minimize user confusion and the

                                                                                             potential of cross mating circuits.

                                                                                             Low Resistance Silver Plated Copper Contacts

                                                                                             • Allows currents up to 350 amps

                                                                                             UL Rated for Hot Plugging up to 75 Amps                                                                              Powerpole® PP180  SECTION 2

                                           Wire to Busbar                                    • Great for battery or other applications where                                                 the  ability  to

                                                                                             interrupt circuits is required

                                                                                             Busbar Contacts Work with Standard Housings

                                                                                             • Provides a hot swappable quick disconnect system for busbar

                                                                                             power distribution

| PP180 ORDERING INFORMATION |

PP180 Housings               

The largest Powerpole® housing can be used with wire

contacts for up to 3/0 AWG [85mm²] or busbar contacts.

Description            -------- Part Numbers --------

Minimum Quantity  ...       250            50    .......                     [ 28.6 ]

Red                    1381G3-BK           1381G3                            1.13                            [ 82.6 ]

Green                  1381G4-BK           1381G4                                                            3.25

Black                  1381G1-BK           1381G1                                        [   28.6  ]                                        [ 30.0 ]

White                  1381G2-BK           1381G2                                            1.13                                           1.18

Blue                   1381-BK             1381                                                                      [ 129.7 ]

                                                                                                                        5.5

                                                                             Front View                            Mated Length

PP180 Silver Plated Wire Contacts

Silver plated contacts offer superior electrical performance and durability up to 10,000 mating cycles.

New contacts for 2/0 to 3/0 AWG (70 to 85 mm²) offer extended capability in the same housings.

                                                                                                                                                    Dimensions

                           Mating                                                                                                        -A-                 -B-              -C-     -D-

AWG    mm²   Force          ---------- Loose Piece Part Numbers -----------            inches         mm     inches  mm      inches  mm     inches  mm

Minimum Quantity  ........       500             300       250       50      ..............................................................................................................

3/0    85    Low                 -               -        1328G2-BK  1328G2            2.35           59.69  0.70    17.78   0.58    14.73  1.04    26.42

2/0    67.4  Low                 -         1328G1-BK       -         1328G1            2.35           59.69  0.64    16.26   0.49    12.45  1.04    26.42

1/0    53.5  High           1382-BK              -         -         1382              2.35           59.69  0.52    13.21   0.44    11.18  1.04    26.42

1      42.4  High           1347-BK              -         -         1347              2.35           59.69  0.52    13.21   0.39    9.91   1.04    26.42

2      33.6  High           1383-BK              -         -         1383              2.35           59.69  0.52    13.21   0.35    8.89   1.04    26.42

4      21.1  High           1384-BK              -         -         1384              2.35           59.69  0.52    13.21   0.30    7.62   1.04    26.42

6      13.3  High           1348-BK              -         -         1348              2.10           53.34  0.37    9.40    0.22    5.59   0.80    20.32

                                                                                                         D                   A

                                                                                                      C

                                                                                                      B                                                                                      [ 12.70 ]

                                                                                                                                                                                             050

All Data Subject To Change Without Notice                                                                                                   www.andersonpower.com                                              -  39  -
                                PP180 Silver Plated Busbar Contacts

                                Use 2 busbar contacts per housing to provide a quick disconnect input or                       See Busbar contact drawing on

                                output busbar connection. Busbar contacts are for mating with wire contacts                    website for further detail.

                                only. Part number 180BBS includes lock nuts. Locknuts must be ordered                                                                                      [ N/A ]

                                separately for 180BBS-BK.                                                                               [ 109.7 ]                                          1/4-20

                                                                                                                                             4.3          [ 2.7 ]                                   [ 25.4 ]

                                                    Mating                                                                                                       0.50                               1.0

                                Thread              Force           ------ Loose Piece Part Numbers ------

                                Minimum Quantity  ................  1,000            120   10          .....

                                Busbar 1/4-20       High            180BBS-BK     180BBS   -

                                Lock Nut 1/4-20     N/A             H1216P7       110G56   110G55

                                                                                                                                                                                  [ 4.6 ]

                                                                                                                                                                                  0.18

           Powerpole® PP180     | PP180 SPECIFICATIONS |

SECTION 2                       Electrical                                                                                  Mechanical               

                                Current Rating Amperes¹                           UL 1977  CSA                Wire Size Range                        AWG               mm²

                                Singlepole (wire-wire) (3/0 AWG)                  350      230                                                       10 to 3/0         5.3 to 85

                                2x2 Block (wire-wire) (3/0 AWG)                   350                                        

                                Singlepole (wire-busbar) (1/0 AWG)                180                         Max. Wire Insulation Diameter          in.               mm

                                                                                                                                                     0.900             22.860

                                                                                                                                           

                                Voltage Rating AC/DC                                                          Operating Temperature²                 °F                °C

                                UL 1977                                           600                                                                -4° to 221°       -20° to 105°

                                                                                                                                           

                                Dielectric Withstanding Voltage                                               Mating Cycles No Load by Plating       Silver (Ag)

                                Volts AC                                          2,200                       Wire and Busbar Contacts               10,000

                                                                                                                                           

                                Avg. Mated Contact Resistance Milliohms¹                                      Avg. Mating / Unmating Force           Lbf.              N

                                6” of 1/0 AWG wire                                0.100                       Wire & Busbar Contacts                 10                44

                                                                                                                                           

                                UL Hot Plug Current Rating Amperes                                            Min. Contact / Spring Retention Force  Lbf.              N

                                250 cycles at 120V DC                             75A                                                                120               534

                                Materials                                                                     Protection

                                Housing                                                                       Touch Safety with Wire Contacts

                                Plastic Resin                       Polycarbonate                             IEC 60529        IP10

                                Contact Retention Spring            Stainless Steel

                                Housing Flammability Rating

                                UL94                                V-0

                                Contact                                                   ¹ Based on: 105°C rated or better cable of the largest size, Properly calibrated APP® recommended tooling, and

                                Base                                Copper Alloy          a 25°C ambient temperature. UL rating not to exceed the maximum operating temperature. CSA rating below a

                                Plating                             Silver                30°C temperature rise.

                                                                                          ² Limited by the thermal properties of the connector plastic housing.

                                Contact Termination Methods                               ³ Use APP® recommended tooling only. Alternate tools may adversely affect the performance of our connectors

                                Crimp³                                                    along with UL and CSA recognition.

                                Hand Solder

                                Wrench / Socket*

                                *Busbar Contacts Only

-          40                -  www.andersonpower.com                                                                                                                  All Data Subject To Change Without Notice
|  PP180 TEMPERATURE CHARTS                                                       |

                                   PP180 Singlepole                                                                                PP180 Multipole

                          Temperature Rise at Constant   Current                                                  60      Temperature Rise at Constant   Current

                  60

                  50                                                                                              50

Temperature (°C)  40                                                                            Temperature (°C)  40

                  30                                                                                              30

                  20                                                                                              20

                  10                                                                                              10

                  0                                                                                               0

                       0  50       100  150  200    250  300  350                                                      0  50       100  150  200    250  300      350      Powerpole® PP180  SECTION 2

                                   Amperes Applied                                                                                 Amperes Applied

                          3/0 AWG       2/0 AWG          1/0 AWG                                                          3/0 AWG       2/0 AWG          1/0 AWG

                          1 AWG              2 AWG           4 AWG                                                        1 AWG              2 AWG            4 AWG

                                   PP180 Singlepole                                                                                PP180 Multipole

                          Derating vs. Ambient Temperature                                                        125     Derating vs. Ambient Temperature

                  125

Temperature (°C)  100                                                                           Temperature (°C)  100

                  75                                                                                              75

                  50                                                                                              50

                  25                                                                                              25

                       0  50       100  150  200  250   300  350    400                                                0  50       100  150  200  250    300  350    400

                                        Amperes Applied                                                                                 Amperes Applied

                          3/0 AWG            2/0 AWG         1/0 AWG                                                      3/0 AWG            2/0 AWG          1/0 AWG

                          1 AWG              2 AWG           4 AWG                                                        1 AWG              2 AWG            4 AWG

   NOTE: Temperature rise charts are based on a 25°C                     ambient  temperature.

All Data Subject To Change Without Notice                                                                                                           www.andersonpower.com  - 41 -
                             |  Powerpole® PP180 Accessories                                                      |

                                Mounting Clamp

                                Mounting clamps can be used for fastening a block of

                                Powerpole® 180 series housings to a panel. Connector                                                   Mounting Clamp

                                blocks must be a complete square for the clamps to work

                                properly. Fastening hardware not included.

                                Description           - Part Numbers -                                                                        Panel

                                Minimum Quantity ...  20 sets of 2       .....                                                                                                                     2  Pole        3 Pole

                                2 Pole                1465G1

                                3 Pole                1465G2

           Powerpole® PP180     Retaining Pins

                                Retaining pins are used to keep stacked Powerpole® 180 series housings from separating.

SECTION 2                       Retaining pins are inserted in the circular opening between two housings stacked side by side.

                                Dimension “B” is +/- .015 in or .38 mm.

                                                                                                                                     Dimensions

                                                                                                                                -A-                    -B-

                                Description           ----- Part Numbers -----                             inches                        mm

                                Minimum Quantity ...  1,000              100    ..................................................................................

                                1 Block High          111812P6      110G18      0.196 / 0.207                          4.98 / 5.26     1.000  25.400

                                2 Block High          111812P8      110G20      0.196 / 0.207                          4.98 / 5.26     1.500  38.100

                                                                               

                                                                                                                                                                                                      B

                                                                                                                                                                                                                  A

                                Reducing Bushings               

                                Use with contact part number 1382-BK to allow a smaller wire to be used with the connector. Electrical

                                capability is derated with smaller wire.                               

                                                                                                                                                                                                              Dimensions

                                                                                                                                                                                                              - ID -

                                Contact Barrel Size   Wire Size                                         ----------------- Part Numbers ----------------             inches  mm

                                Minimum Quantity .....................................................     1,500       1,000        500       100        ............................

                                1/0 AWG [53.5 mm²]    #1 AWG [42.4 mm²]                                 -              -            5687-BK   5687                  0.39                  9.91       [  25.4  ]

                                1/0 AWG [53.5 mm²]    #2 AWG [33.6 mm²]                                 5690-BK        -            -         5690                  0.34                  8.64                            ID

                                1/0 AWG [53.5 mm²]    #4 AWG [21.2 mm²]                                 -              5693-BK      -         5693                  0.27                  6.86          1.0

                                1/0 AWG [53.5 mm²]    #6 AWG [13.3 mm²]                                 -              5663-BK      -         5663                  0.22                  5.59

                                1/0 AWG [53.5 mm²]    #10 - 8 AWG [5.3 - 8.4 mm²]                       5648-BK        -            -         5648                  0.19                  4.83

                                                                                                                                                                                                            Wire  Entrance

                                For environmentally sealed connector shells to hold Powerpole®

                                15-180 connectors, see APP®’s SPEC Pak® product series on our

                                website, www.andersonpower.com

-          42                -  www.andersonpower.com                                                                                                                                                 All Data Subject To Change  Without  Notice
Powerpole®

- Tooling Information

Wire       Size        Loose Piece Part Numbers         Loose Piece Contact Crimp Tool                      Reeled Part  Numbers   Reeled Contact Crimp Tools

                                                                 Pneumatic

                       Tin                 Silver       Hand     Bench                           Number     Tin           Silver                ATS  ATS          Air Feed

AWG        mm²         Plating             Plating      Tool or  Tool       +  Die   +  Locator  of Crimps  Plating       Plating  Applicator        Press        Kit*

                                                                 PP15 / 45 Flat Wiping Power & Ground

16  /  20  1.3 / 0.52  N/A                 1332                  1367G1                                     N/A           N/A                   N/A  N/A          N/A

12  /  16  3.3 / 1.3   N/A                 1331         1309G2

16  /  20  1.3 / 0.52  262G1-LPBK          262G2-LPBK   or                                                  262G1         262G2    1385519-1

16  /  20  1.5 / 0.52  200G2L-LPBK         200G4L-LPBK  1309G8                                              200G2L        200G4L                TBD

16  /  20  1.3 / 0.52  269G2-LPBK          N/A                                                              269G2         N/A      1385519-1                                  Powerpole® Tooling  SECTION 2

12  /  16  3.3 / 1.3   261G1-LPBK          261G4-LPBK            N/A           N/A      N/A      Single     261G1         261G4    1385520-1

10  /  14  5.3 / 2.1   261G2-LPBK          261G3-LPBK   1309G3                                              261G2         261G3    1385458-1         1725900-2    1424266-1

                                                        or                                                  269G1                  1385520-1         or           or

12  /  16  3.3 / 1.3   269G1-LPBK          N/A          1309G8                                                            N/A                        [3-54500-1]  [354578-1]

10  /  14  5.3 / 2.1   269G3-LPBK          N/A                                                              269G3         N/A      1385458-1

10  /  14  6.0 / 2.1   200G1L-LPBK         200G3L-LPBK  1309G6                                              200G1L        200G3L   1385460-1

10  /  14  6.0 / 2.1   201G1H-LPBK         201G3H-LPBK  or                                                  201G1H        201G3H   1385460-1

10  /  14  6.0 / 2.1   1830G1-LPBK         1830G2-LPBK  1309G8                                              1830G1        1830G2   1385460-1

                                                                                     PP75

    #6     13.3                            1307

                                           5900                             1388G6                          265G5                  1385523-1         2-565435-2   692655-1

    #8     8.4         N/A                 5952         1309G4   1387G1              1389G6      Single                   N/A

                                           5953                                                                                                      1725900-2    1424266-1

#10 / 12   5.3 / 3.3                                                        1388G7                          265G6                  1385522-1         or           or

                                           5915                                                                                                      [3-54500-1] [354578-1]

                                                                                     PP120

    1/0    53.5                            1323G2                           1388G3

    #1     42.4                            1323G1

    #2     33.6        N/A                 1319         1368     1387G1              1389G4      Single              N/A                             N/A

    #4     21.2                            1319G4                           1388G4

    #6     13.3                            1319G6

                                                                                     PP180

3/0        85                              1328G2                           1303G12

2/0        53.5                            1328G1                1387G2              1304G32     Double

1/0        53.5                            1382                             1303G13

    #1     42.4        N/A                 1347         1368     1387G1     1388G3   1389G3      Single              N/A                             N/A

    #2     33.6                            1383

                                                                 1387G2     1303G13  1304G32     Double

    #4     21.1                            1384                  1387G1     1388G3   1389G3      Single

                                                                 1387G2     1303G13  1304G32     Double

    #6     13.3                            1348                  1387G1     1388G4   1389G3      Single

* All ATS applicators for APP® contacts are air feed style, (except 1385870) and require the press          to have an air feed kit installed.

    NOTE: See website for the most current information.

All Data Subject To Change Without Notice                                                                                          www.andersonpower.com                      - 43 -
           Overview of SBS®, SB® & SBX® / SBO®

           - Main Differentiating Features

                                                                                                       SBS®: The “Storage Battery Safety” connector provides

                                                                                                       a  compact      connection       with  a    touch  safe   interface.    The

                                                                                                       newest series of the Multipole connector continues to add

                                                                                                       new features and capabilities.

                                                                                                       SB®: Based on the original “Storage Battery” connector that

                                                                                                       pioneered flat wiping contact technology over a half century

                                                                                                       ago. Two to three positions in a genderless mechanically-keyed

                                                                                                       housing are suitable for a wide array of power connection

                                                                                                       applications.

                                                                                                       SBX®: The addition of auxiliary positions to the SB® created

                                                                                                       the “Storage Battery Auxiliary” connector. Up to 8 auxiliary

                                                                                                       positions allow expanded capabilities for the Multipole family

                                                                                                       by allowing intelligent power switching, monitoring of battery

                                                                                                       charge status, and other signal functions to be integrated

                                                                                                       into a single connector.

                                                                                                       SBE®: By modifying the SBX® housing the “Storage Battery

                                                                                                       European” connector was created. The SBE® housings are

                                                                                                       molded from a chemical resistant PBT resin and the SBE®320

           Multipole Family                                                                            features improved touch safety over the SBX®350 design.

SECTION 3                                                                                              SBO®:      Designed          to  meet  the  needs  of  connecting     office

                                                                                                       equipment, the “Storage Battery Office” connector is molded

                                                                                                       out of durable PC like the original SB® but incorporates the

                                                                                                       auxiliary positions of the SBX® in a housing similar to the

                                                                                                       SBE®80.

                                     Hot Plugging AC or DC

                                     Contacts feature a sacrificial tip that

                                     allow high current circuit interrupt     Genderless Housings

                                                                              Provide  simplified   assembly      and

                                                                              minimize the number of components

                             Low Resistance Connection

                             Silver or tin plated contacts                                                             Keyed & Color Coded Housings

                             inside  housings  that  strongly                                                          Prevents accidental cross mating

                             force the contacts together                                                               of circuits

                                     Self Securing Design

                                     Stainless            steel  springs   create  a                                                               Compact Power to Size Ratio

                                     robust force between the contacts                                                                             Maximizes    valuable  PCB  edge

                                     that      holds      the    connector    in  the                                                              real estate with a compact high

                                     mated condition                                                                                               power design

                                                                                       Auxiliary or Ground Positions

                                                                                       For  signal  transmission  or   the

                                                                                       added   safety     of  a   premate

                                                                                       ground

- 44 -                       www.andersonpower.com                                                                                                 All Data Subject To Change Without Notice
|  MULTIPOLE FAMILY SELECTION GUIDE                                |

                                           SBS® Connector  SB® Connector  SBX® /  SBE® /     SBO®  Connectors

   Page Number                             49                  57                 77

   Amps Per Pole                           50 - 110        50 - 450               60 - 350

   Volts (UL) Per Pole                     600             600                    600

   Wire Gauge (AWG)                        16 - 6          16 - 300               16 - 300

   Wire Gauge (mm²)                        1.3 - 13.3      1.3 - 152              13.3 - 152

   Number of Power Circuits                2-3             2-3                            2

   Number of Auxiliary Circuits            4                   0                          8

   PCB Mount                               ●                   ●

   Bus Bar                                                     ●

   Panel Mount                             ●                   ●

   Hot Plug                                ●                   ●                          ●

   Touch Safe                              ●                                              ●

   Mechanically Keyed                      ●                   ●                          ●

   Handle                                  ●                   ●                          ●

   Air Supply System                                                                      ●

Actual Size - Connector Half                                                                                              Multipole Family  SECTION 3

   SB®50                                               SB®120                                SB®175 - 2 Pole

All Data Subject To Change Without Notice                                                          www.andersonpower.com  - 45 -
                             Actual Size - Connector Half

SECTION 3  Multipole Family  SB®175 - 3 Pole                           SB®350

                             SBE®60 - SBO®80               SBE®160  -  SBX®175

- 46 -                       www.andersonpower.com                     All Data  Subject  To  Change  Without  Notice
                                                                                                SBS®50

                                                                                                                       Multipole Family  SECTION 3

                                           SBE®320 - SBX®350                                    SBS®75X
                                                                                                                                                                             &
                                                                                                                                                                      SBS®75G

Explanation of Mechanical Voltage Keys

Features molded into the mating interface of the connector housing

prevent  accidental                        cross  mating  of  circuits.  This  molded  feature

mechanically keys the connection so that only housings with the same

mating interface can be mated together.

Different mechanical keys can be easily recognized by the color of

the housing. This color coding corresponds to a voltage that industrial

trucks, batteries, and chargers have adopted as a standard to prevent

incompatible voltages from cross mating.

The same mechanical keying and color coding that is so successful for

industrial trucks, is also widely used in power electronics applications.

UPS systems, power supplies, personal mobility, and alternative

energy applications have all used this feature to ensure user safety.

Note: Some housings in the SB®50, SB®175, and SB®350 series have

different colored housings with a shared mechanical keying feature.

Please see the specific data sheet for details.

All Data Subject To Change Without Notice                                                       www.andersonpower.com  - 47 -
                                                    | Scratch Pad |

SECTION 3  Multipole Family

           - 48 -            www.andersonpower.com                   All Data Subject To Change Without Notice
SBS® Connectors

- up to 105 amps

                                                                               The  patented            SBS®  connector        family      is   designed       to

                                                                               provide high power in a compact ergonomic housing

                                                                               with protection against accidental contact with live circuits.

         SBS®75G                                                               This is of particular importance in applications where

                                                                               DC   voltages            exceed  30      volts  and         can      be     health

                                                                               threatening.

                                           SBS®75X                             Wire-to-wire    and         wire-to-board           configurations             both

                                           Wire to Wire                        provide   power          contacts      rated  up        to  105    amps.       The

                                                                               SBS®75X offers up to 4 mate-last break-first auxiliary

                                                                               power contacts rated up to 20 amps. The SBS®75G

                                                                               features a third first-mate last-break ground or power

                                                                               contact.  All   contact          positions      are         rated    for    circuit

                                                                               interruption (hot plugging).

                                                                               • Touch Safe Interface

                                                                               - Can safely be used in through panel applications

                                                                               - Minimizes potential contact with live circuits per IEC 60950

                                                                               • Wire-to-Wire and Wire-to-Board Configurations

                                                                               Allows one connector to meet multiple needs

                                                                               • Ground or Auxiliary Contacts Integrated into the

                                                                               One Piece Housing                                                                    SBS®  SECTION 3

                                                                               Meets all connection requirements in one compact

                                                                               connector housing

|  SBS® ORDERING INFORMATION                                                |

   SBS®50 Standard Housings                       

   Polycarbonate housings feature 2 positions all finger proof.

   Genderless design mates with itself. Mechanical keys are

   color coded.

                  Voltage                                                                                                                  [ 19.1 ]

                  Color                                                                                             [ 3.6 ]                       0.75                 [ 6.3 ]

   Description    Code           ----------- Part Numbers -----------                        0.14 (2)                                             0.25

   Minimum Quantity      ......  500                50                 ...

   Red            24V            SBS50RED-BK   SBS50RED

   Gray           36V            SBS50GRA-BK   SBS50GRA

   Blue           48V            SBS50BLU-BK   SBS50BLU                                                                                        [ 36.1 ]

   Green          72V            SBS50GRN-BK   SBS50GRN                                                                                           1.42

   Black          80V            SBS50BLK-BK   SBS50BLK                             [  18.0 ]

   Brown          96V            SBS50BRN-BK   SBS50BRN                                0.71

   White          192V           SBS50WHT-BK   SBS50WHT

                                                                                                                                       Material ID

   SBS®50 Chemical Resistant (CR) Housings                                                                                             P = Chemical Resistant

   Same features as the standard housings, but molded out of a                                 [ 55.8   ]

   chemical resistant PBT/ PC blend.       Suitable for use to -40°C.                          2.20

                  Voltage                                                                                                                                         [ 16.5 ]

                  Color                                                                                                                                 0.65

   Description    Code           ------------ Part Numbers -------------

   Minimum Quantity      ......  500                50                 ...                                      [84.8]

   Red            24V            PSBS50RED-BK  PSBS50RED                                                        3.34

   Gray           36V            PSBS50GRA-BK  PSBS50GRA

   Blue           48V            PSBS50BLU-BK  PSBS50BLU

   Green          72V            PSBS50GRN-BK  PSBS50GRN

   Black          80V            PSBS50BLK-BK  PSBS50BLK

   Brown          96V            PSBS50BRN-BK  PSBS50BRN

All Data Subject To Change Without Notice                                                                                    www.andersonpower.com                  - 49 -
                 SBS®75X Standard Housings

                 Polycarbonate housings feature 4 auxiliary and 2 primary positions

                 all finger proof. Genderless design mates with itself, or the PCB                                                                                Front View

                 connector.   Mechanical keys are color coded.                                                                                           Primary Power Contacts

                              Voltage                                                                                                                                                                [ 15.2 ]

                              Color                                                                                                                                                          0.60

                 Description  Code          ------------ Part Numbers -------------

                 Minimum Quantity    .....  250                 50             ...                                                                       Pin                  Socket

                 Black        80V           SBS75XBLK-BK        SBS75XBLK                                                                                      [ 46.0 ] 1.81

                 Brown        96V           SBS75XBRN-BK        SBS75XBRN

                 SBS®75X Chemical Resistant (CR) Housings                                                              Bottom       View

                 Same features as the standard housings, but molded out of a                                                                                                                                     [  28.9  ]

                 chemical resistant PBT/ PC blend.  Suitable for use to -40°C.                                                                                                                                      1.14

                                                                                                                                                   [  32.5 ]

                              Voltage                                                                                 [  55.9     ]                                 1.28

                              Color                                                                                      2.20                                                                                  [ 84.8 ]

                 Description  Code          ------------- Part Numbers --------------                                                                                                            3.34

                                                                                                                                                      [ 32.5   ±   0.13 ]              Mated Length

                 Minimum Quantity    .....  250                 50                   ....                                                             0.750    ±   0.005

                 Green        72V           PSBS75XGRN-BK       PSBS75XGRN

                 Black        80V           PSBS75XBLK-BK       PSBS75XBLK

                                                                                                                    Material ID

                                                                                                                    P = Chemical    Resistant

                 SBS®75X Assembled PCB Connector

                 Fully assembled PCB connector is designed to mate with SBS®75X                                                                                                        Mated Length

                 Wire connector. All positions are preloaded with contacts including                                                                             Side View                       [ 74.9 ]

                 standard mating length auxiliary positions. Press fit board locks                                     Back View    [ 15.7 ]                      [ 46.1 ]                         2.95

                 help secure the connector to the PCB before and after soldering.                                                   0.62                           1.81

                              Voltage               

SECTION 3                     Color                                                                                                                                       [ 26.92 ]

                 Description  Code          ---------------- Part Numbers ---------------                              [ 56.8 ]                                1.06

                 Minimum Quantity    .....          100                    50              .....  [ 4.0 ]              2.24         [ 4.1 ]                       [ 41.00 ]
                                                                                                  0.16     (4)                      0.16     (4)                   1.614
                 Black        80V           SBS75XPRBLK-BK      SBS75XPRBLK

           SBS®                                                                                   See PCB       connector drawing on website             for further detail.

                 SBS®75G Wire Housings

                 Polycarbonate housings feature three finger proof positions. The                                                                                                      [ 46.0 ]

                 center position can be used for pre-mate power or ground. Genderless                                                                                                  1.81

                 design mates with itself, or the PCB connector. Mechanical keys are color

                 coded.  Inquire with customer service for chemical resistant housings.                                                                                                                    [ 15.2         ]

                                                                                                                                                                                                                 0.60

                              Voltage                                                                                                                               [  41.4 ]

                              Color                                                                                   [ 59.4 ]                                         1.63                 Premate  Ground / Power

                 Description  Code          ------------ Part Numbers -------------                        2.34                                                                                        [ 28.9 ]

                 Minimum Quantity    .....  250                 50         .....                                                                                                                           1.14

                 Gray         36V           SBS75GGRA-BK        SBS75GGRA

                 Blue         48V           SBS75GBLU-BK        SBS75GBLU                                                                                [ 14.5 ]                      [ 84.8 ]

                 Black        80V           SBS75GBLK-BK        SBS75GBLK                                                                                   0.57                       3.34

                 Brown        96V           SBS75GBRN-BK        SBS75GBRN                                              Material ID                                                     Mated Length

                                                                                                                       P = Chemical Resistant

                 SBS®75G Assembled PCB Connector

                 Fully assembled PCB connector is designed to mate with SBS®75G                                                                                                                  Mated Length

                 Wire connector. Has press fit board locks to help secure the connector                                Back View                                  Side View                        [ 74.9 ]

                 to the PCB before and after soldering.                                                                [ 56.8 ]                                    [ 49.6]                                 2.95

                              Voltage                                                                                                2.24                  [ 5.7 ]               1.95

                              Color                                                                                                                        0.62

                 Description  Code          ---------------- Part Numbers ---------------

                 Minimum Quantity    .....  100                            50          ......              [ 4.0 ]                  [ 3.4 ]                   [ 19.1 ]

                 Black        80V           SBS75GPRBLK-BK      SBS75GPRBLK                                0.16                     0.13                       0.75

                                                                                                           TYP                      TYP

                 See PCB connector drawing on website for further detail.

- 50 -           www.andersonpower.com                                                                                                                                        All Data Subject To Change Without             Notice
SBS® Silver Plated Primary Power Wire Contacts               

Use two silver plated contacts per housing for the best electrical performance                                                       [ 7.6 ]

and durability up to 10,000 mating cycles. Standard contacts are for use in all                                                      0.30

         primary          power p         ositions for SBS® 50, 75X, & 75G wire housings.                                                                                        [ 39.4 ]

                                                                                                               Dimensions                                                                                                     1.55                                   [ 12.4 ]

                                                                Loose Piece                            -A-                                                                                                                 0.49

Type         AWG       mm²                 ------ Part Numbers ------       inches mm

Minimum Quantity       ..................  1,000                       100  ...................                                                                                                 A

Standard     6         16                  1339G2-BK   1339G2               0.22  5.59                                                                                                                          [ 7.3 ]

Standard     8         10                  1339G5-BK   1339G5               0.19  4.83                                                                                                                          Ø 0.29

Standard     12 to 10  4 to 6              1339G3-BK   1339G3               0.14  3.56

SBS®75G Silver Plated Pre-Mate Wire Contacts                                                                                                                                                       Ground Indicator

Pre-Mate contacts are for the center Pre-Mate position on the SBS®75G                              wire  housings.                   [ 7.6 ]

                                                                                                               Dimensions                                               0.30

                                                                Loose Piece                      -A-

Type         AWG       mm²                 ------ Part Numbers ------       inches mm                                                                       [  41.9  ++--01..056  ]

Minimum Quantity       ..................  500                         50   .....................                                                              1.65                                   [ 12.4 ]

Pre-Mate     6         16                  1340G1-BK   1340G1               0.22  5.59                                                                                                                 0.49

Pre-Mate     8         10                  1340G2-BK   1340G2               0.19  4.83

Pre-Mate     12 to 10  4 to 6              1340G3-BK   1340G3               0.14  3.56                                                                                                          A

                                                                                                                                                                                                                [ 7.3 ]

                                                                                                                                                                                                                Ø 0.29

Pin Contacts for 1x4 Auxiliary Connector                               

G         old plated         contacts         are availa         ble in 4 lengths to allow sequencing of circuits.

Description                 AWG            mm²                              ----------------- Part Numbers ----------------                                                                                                 SBS®    SECTION 3

Minimum Quantity ....................................................       500                          50             ...........

Standard Length 7.7mm       12             2.5                              PM16P12S30             PM16P12S30-50

                            16 to 14       1.0 to 1.5                       PM16P1416S30           PM16P1416S30-50                                                    Retention Clip

                            20 to 16       0.75 to 1.0                      PM16P1620S30           PM16P1620S30-50                                                                                    [ 1.60 ]

                            24 to 20       0.50 to 0.75                     PM16P2024S30           PM16P2024S30-50                            ID                                                      Ø 0.06

Pre-Mate 9.3mm              12             2.5                              PM16P12A30             PM16P12A30-50

                            16 to 14       1.0 to 1.5                       PM16P1416A30           PM16P1416A30-50

                            20 to 16       0.75 to 1.0                      PM16P1620A30           PM16P1620A30-50                                                                        L1

                            24 to 20       0.50 to 0.75                     PM16P2024A30           PM16P2024A30-50                                                    L

Pre-Mate 8.5mm              12             2.5                              PM16P12B30             PM16P12B30-50

                            16 to 14       1.0 to 1.5                       PM16P1416B30           PM16P1416B30-50

                            20 to 16       0.75 to 1.0                      PM16P1620B30           PM16P1620B30-50                            Auxiliary Pin                               -L-              - L1 -

                            24 to 20       0.50 to 0.75                     PM16P2024B30           PM16P2024B30-50                            Contact Lengths                        in.        mm    in.       mm

Post-Mate 6.4mm             12             2.5                              PM16P12C30             PM16P12C30-50                              Standard Length 7.7mm                  0.77       19.6  0.30      7.7

                            16 to 14       1.0 to 1.5                       PM16P1416C30           PM16P1416C30-50                            Pre-Mate 9.3mm                         0.83       21.2  0.37      9.3

                            20 to 16       0.75 to 1.0                      PM16P1620C30           PM16P1620C30-50                            Pre-mate 8.5mm                         0.80       20.4  0.33      8.5

                            24 to 20       0.50 to 0.75                     PM16P2024C30           PM16P2024C30-50                            Post-Mate 6.6mm                        0.72       18.3  0.25      6.4

Socket Contacts for 1x4 Auxiliary Connector

S         electively         gold plate         d contacts         offer low resistance and durability up to 10,000 mating cycles.                                                                               [ 19.6 ]
                                                                                                                                                                                          0.77

Description                     AWG                     mm²                                      -------------------- Part Numbers -------------------

Minimum Quantity ..................................                                  500                50             .............

Socket Contact    12                      2.5                                      PM16S12S32           PM16S12S32-50                                                               ID

                                16 to 14  1.0 to 1.5                               PM16S1416S32         PM16S1416S32-50                                                                                                                        [ 2.6 ]

                                                                                                                                                                     Retention       Socket                        0.10

                                20 to 16  0.75 to 1.0                              PM16S1620S32         PM16S1620S32-50                                                                           Clip                Insert

                                24 to 20  0.50 to 0.75                             PM16S2024S32         PM16S2024S32-50

                                                                                                                                              Auxiliary Socket Contacts

                                                                                                                                              Crimp Barrel ID

                                                                                                                                              Wire Gauge       in.    mm.

                                                                                                                                              #24 / 20         0.04   1.1

                                                                                                                                              #20 / 16         0.07   1.7

                                                                                                                                              #16 / 14         0.08   2.1

                                                                                                                                              #12              0.10   2.6

All Data Subject To Change Without Notice                                                                                                                             www.andersonpower.com                                 - 51 -
                    | SBS® CONNECTOR SPECIFICATIONS |

                    Electrical                                                                         Mechanical

                    Current Rating Amperes¹                                 UL 1977          CSA/TUV                 Wire Size Range                         AWG                mm²

                    Primary Power (6 AWG)                                   110              75                      Power Contacts                          16 to 6            1.3 to 13.3

                    Auxiliary (12 AWG)                                             20               10                      Auxiliary Contacts                      24 to 12           0.25 to 3.3

                                                                                                                                            

                    Voltage Rating AC/DC                                                               Max. Wire Insulation Diameter           in.                mm

                    UL 1977                                                               600                                      SBS®75G Power & Ground                  0.380              9.652

                                                                                                                     SBS®50 & SBS®75X Power Contacts         0.410              10.414

                    Dielectric Withstanding Voltage                                                    SBS®75X Auxiliary Contacts              0.140              3.600

                    Volts AC                                                              2,200                                                           

                                                                                                                     Operating Temperature²                  °F                 °C

                    Avg. Mated Contact Resistance Milliohms¹                                           Standard                                -4° to 221°        -20° to 105°

                    Power & Ground: 1 1/4” of #6 AWG wire     0.200                                    Chemical Resistant                      -40 to 221°        -40° to 105°

                    Auxiliary: Wire & PCB                                          3.000                                                           

                                                                                                                     Mating Cycles No Load by Plating        Silver (Ag)        Tin (Sn)      Gold (Au)

                    UL Hot Plug Current Rating Amperes - 250 cycles at 120V DC                         Power & Ground Contacts Wire            10,000               

                    Wire & PCB Power                                               50A                                      Power & Ground Contacts PCB                                              1,500

                    Wire & PCB Auxiliary                                           5A                                       Auxiliary Contacts                                                                            10,000

                                                                                                                                            

                    UL Ground Short Time Current Test - SBS75G Wire & PCB                              Avg. Mating / Unmating Force            Lbf.               N

                    1530 Amps, #6 AWG Wire                                  6 seconds                                SBS®75X and SBS®75G      Wire to Wire   16                 70

                                                                                                       SBS®50     Wire to Wire                 8                  36

                                                                                                       SBS®75X    and SBS®75G Wire to PCB      8                  36

                                                                                                                              

                                                                                                       Min. Contact / Spring Retention Force   Lbf.               N

                    Materials                                                                          Power, Standard Housing                 50                 222

                    Housing                                                                            Power, Chem. Resistant Housing          30                 133

                    Standard Plastic Resin           Polycarbonate                                     Aux. Standard Housing                   15                 67

                    Chem. Resistant Resin            Polycarbonate / PBT blend                         Aux. Chem. Resistant Housing            10                 44

                    Contact Retention Spring         Stainless Steel                                                          

                                                                                                       PCB Specifications                       

                    Housing Flammability Rating                                                        Mounting Style                          Plated Through Hole               

SECTION 3           UL94                                                  V-0                                               Max PCB Thickness- in. [mm]             0.093 [2.4]                 

                                                                                                       Recommended Traces Power & Ground       #6 AWG Cross Section               

                    Wire Power & Ground Contact      Silver Plated Copper Alloy                        Recommended Traces Auxiliary            #12 AWG Cross Section               

                                                                                                                              

           SBS®     PCB Power & Ground Contact       Tin Plated Copper Alloy                           Min. Creepage / Clearance Distance PCB  in.                mm

                                                                                                       Power to Aux. Creepage SBS®75X          0.41               10.4

                    SBS75X Auxiliary Contacts                                                          Power to Aux. Clearance SBS®75X         0.24               6.1

                    Pin                                                   Copper alloy, Au over Ni                          Power to Ground Creepage SBS®75G        0.35               8.9

                    Socket                                                BeCu, Au over Ni                                  Power to Ground Clearance SBS®75G       0.26               6.7

                    Socket Body                                    Copper alloy, Sn bright over  Ni                  Auxiliary Creepage SBS®75X              0.12               3.0

                    Retention Clip                                 Stainless Steel                                   Auxiliary Clearance SBS®75X             0.12               3.0

                    PCB Press Fit Retainers          Brass - Tin Plated                                Protection

                                                                                                       Touch Safety with Wire Contacts & PCB   Mating  Interface

                    Contact Termination Methods                                                        IEC 60950              Pass

                    Crimp³                                                Wire Contacts                                     IEC 60529              IP20

                    Hand Solder                                    Wire and PCB Contacts

                    Solder Dip                                     PCB Contacts

                    Wave Solder                                    PCB Contacts

                    Auxiliary contacts are available for SBS®75X only.

                    SBS®75X and SBS®75G PCB connectors are designed to             mate    only  with  the wire connector of the same series.

                    ¹ Based on: 105°C rated or better cable of the largest size, Properly calibrated APP® recommended tooling, and a 25°C ambient temperature. UL rating not to exceed

                    the maximum operating temperature. CSA rating below a 30°C temperature rise.

                    ² Limited by the thermal properties of the connector plastic housing.

                    ³ Use APP® recommended tooling only. Alternate tools may adversely affect the performance of our connectors along with UL and CSA recognition.

-          52    -  www.andersonpower.com                                                                                                              All Data Subject To Change Without Notice
|  SBS® CONNECTOR TEMPERATURE CHARTS |

                                  SBS®75x Primary Contacts Only                                                SBS®75x Primary Contacts Only                                                       SBS®50

                              Temperature Rise at Constant Current                                         Derating vs. Ambient Temperature                                         Temperature Rise at Constant Current

                     60                                                                          125.0                                                                      60

                     50                                                                                                                                                     50

   Temperature (°C)                                                            Temperature (°C)  100.0                                                    Temperature (°C)

                     40                                                                                                                                                     40

                     30                                                                          75.0                                                                       30

                     20                                                                                                                                                     20

                                                                                                 50.0

                     10                                                                                                                                                     10

                        0                                                                        25.0   0      20  40      60  80      100  120     140                     0

                           0  10  20 30   40  50  60  70  80  90 100 110  120                                                                                                    0  20         40      60      80   100     120

                                          Amperes Applied                                                              Amperes Applied                                                         Amperes Applied

                                          6 AWG           8 AWG                                                    6 AWG                8 AWG                                       6 AWG          10 AWG           12 AWG

                                      10 AWG              12 AWG                                                   10 AWG              12 AWG

                              SBS®75x Auxiliary Contacts @ 10A                                             SBS®75x Auxiliary Contacts @ 10A                                                        SBS®50

                              Temperature Rise at Constant Current                                         Derating vs. Ambient Temperature                                         Derating  vs. Ambient Temperature

                     60                                                                          125.0                                                                      125

                     50

(°C)                                                                           (°C)              100.0                                                    Temperature (°C)  100

Temperature          40                                                        Temperature

                     30                                                                          75.0                                                                       75                                                      SBS®   SECTION 3

                     20

                                                                                                 50.0                                                                       50

                     10

                     0                                                                           25.0                                                                       25

                           0  10  20  30  40  50  60  70  80  90  100     110                          0   10  20  30  40  50  60  70  80   90 100  110                          0  20     40      60      80  100  120     140

                                          Amperes Applied                                                              Amperes Applied                                                        Amperes Applied

                                      6 AWG               8 AWG                                                    6 AWG               8 AWG                                        6 AWG          10 AWG           12 AWG

                                      10 AWG              12 AWG                                                   10 AWG              12 AWG

                              SBS®75x Auxiliary Contacts @ 20A                                             SBS®75x Auxiliary Contacts @ 20A

                              Temperature Rise at Constant Current                                         Derating vs. Ambient Temperature

                     60                                                                          125.0

                     50

Temperature (°C)                                                               Temperature (°C)  100.0

                     40

                     30                                                                          75.0

                     20

                                                                                                 50.0

                     10

                     0                                                                           25.0

                           0  10  20  30  40  50  60  70  80  90  100     110                           0  10  20  30  40  50  60  70   80  90  100  110

                                          Amperes Applied                                                              Amperes Applied

                                      6 AWG               8 AWG                                                    6 AWG                8 AWG

                                      10 AWG              12 AWG                                                   10 AWG              12 AWG

   NOTE: Temperature rise charts are based on a 25°C                           ambient temperature.

All Data Subject To Change Without Notice                                                                                                                                           www.andersonpower.com                        -  53  -
                                                                                                                                                                                                                    SBS®75G Primary Contacts Only

                                              SBS®75G All Contacts Powered                                                   SBS®75GPR All Contacts Powered                                                                 No Power Center Contact

                                              Temperature Rise at Constant Current                                           Temperature Rise at Constant Current                                           60      Temperature Rise at Constant Current

                                      60                                                                             60

                                      50                                                                             50                                                                                     50

                    (°C)              40                                                           (°C)              40                                                                   Temperature (°C)  40

                    Temperature       30                                                           Temperature       30                                                                                     30

                                      20                                                                             20                                                                                     20

                                      10                                                                             10                                                                                     10

                                      0                                                                              0                                                                                      0

                                          0   20  40      60      80               100     120                            0  10          20  30  40    50  60    70  80    90  100                               0  10  20 30  40  50   60   70  80  90 100 110  120

                                                  Amperes Applied                                                                            Amperes Applied                                                                   Amperes Applied

                                                  6 AWG                       8 AWG                                                          6 AWG               8 AWG                                                         6 AWG             8 AWG

                                                  10 AWG          12 AWG                                                                     10 AWG              12 AWG                                                     10 AWG               12 AWG

                                                                                                                                                                                                                        SBS®75G Primary Contacts Only

                                              SBS®75G All Contacts Powered                                                   SBS®75GPR All Contacts Powered                                                                 No Power Center Contact

                                              Derating vs. Ambient Temperature                                               Derating vs. Ambient Temperature                                                       Derating vs. Ambient Temperature

                                      125                                                                            125                                                                                    125

                    Temperature (°C)  100                                                          Temperature (°C)  100                                                                  Temperature (°C)  100

                                      75                                                                             75                                                                                     75

                                      50                                                                             50                                                                                     50

                                      25                                                                             25                                                                                     25   0      20     40  60        80      100   120   140

                                           0  20  40  60      80              100    120    140                           0      20          40        60        80  100       120

                                                      Amperes Applied                                                                            Amperes Applied                                                                   Amperes Applied

SECTION 3                                         6 AWG                       8 AWG                                                          6 AWG               8 AWG                                                         6 AWG                 8 AWG

                                                  10 AWG                      12 AWG                                                         10 AWG              12 AWG                                                        10 AWG            12 AWG

                    NOTE: Temperature rise charts are based on 25 °C ambient temperature.

           SBS®     | SBS® Accessories |

                    Mounting Clamp for SBS®50                                                                                                                        [ 20.8 ]  [ 20.8 ]      [ 20.8  ]

                    Mounting clamps can be used for fastening a SBS®50 series                                                                          0.82          0.82      0.82       [ 4.6 ]                              [ 1.5 ]

                    housings to a panel.              Fastening hardware not included.                                                                                                    Ø 0.18 TYP                           0.06                  [ 26.4 ]

                    Description                                               --- Part Number ---                                                                                                                                                    1.04

                    Minimum Quantity              ..........................       20 sets of 2  .....                                       [ 25.1 ]                                  [  33.5 ]

                    Panel Mount Bracket for SBS®50                                   1466G1                                                      0.99                                     1.32

                                                                                                                                                                                                                                   [ 28.2 ]

                                                                                                                                                                                                                                   1.11

                                                                                                                                                                 [ 50.0 ]

                                                                                                                                                                     1.97

                    T-Handle for SBS®50 and SBS®75X

                    The “T” handle makes mating and unmating the connector easier. The

                    non-conductive red plastic material is strong and safe. (2) Self tapping

                    s         crews are         used to          secure the         handle to         the conn         ector housing.

                    Description                                                    ---------- Part Numbers ----------

                    Minimum Quantity              ...............................    1,000                           50      ..........

                    Red “T” Handle + Hardware Bag                                       -        SBS50-HDL-RED

                    Hardware Bag (2 Screws)                                             -        104G17               

                    Red “T” Handle Only                                            113899P1                              -               

                    #8 x 5/8” Screw (Order 2 Per Handle)                           H1120P41                              -               

                                                   

-          54    -                    www.andersonpower.com                                                                                                                                                             All Data Subject To Change Without Notice
T-Handle for SBS®75G                       

The “T” handle makes mating and unmating the connector easier. The non-conductive

red plastic material is strong and safe. (2) Machine screws and lock nuts.                                   

Description                                        --- Part Number ---

Minimum Quantity  ..............................             50   .........

Red “T” Handle + Hardware Bag                      SBS75GHDL-RED

                               

Dust Cover SBS®50                               

Prevents dust and dirt from entering the mating interface of the                                                                                                                    Shown with the SB®50

connector when unmated. NOTE: Not a Hermetic Seal.

Description                                        ---- Part Number ----

Minimum Quantity  ...............................  500            50       ...

Dust Cover with Lanyard Strap, Red                 113890P1       134G1                                                                                                             Slide cover over

                                                                                                                                                                                    mating end.

Cable Clamps for SBS®50                                                       

Durable metal cable clamps securely hold cables to prevent accidental strain or pulls from dislodging
wire or contacts from the housing. Cable clamps are recommended for solder terminated wires.                         5905

                                                   Cable Size                                               

                                                   AWG or                    mm² or                                                                                                 Shown with the SB®50

Description                                        (Inches O.D.)             (mm O.D.)                          ----- Part Numbers -----                                                                   SBS®    SECTION 3

Minimum Quantity  ............................................................................................           500   50        ...                                        Bolt on bundled

Self Attaching for Discrete Conductor              8 to 6                    10                                 990-BK         990                                                  conductors.

Self Attaching for Discrete Conductor              12 to 10                  4 to 6                             990G2-BK       990G2

Bolt On for Discrete Conductor                     12 to 6                   4 to 10                            990G1-BK       990G1

Bolt On for Bundled Conductor                      (0.320 to 0.450)          (4.27 to 11.43)                    5905-BK        5905

                                                                                                                                                           The given wire O.D. information is an esti-

                                                                                                                                                           mate. Cable clamps should be evaluated for

                                                                                                                         990                               performance with the actual wire to be used.

                                                                  Self attaching discrete conductor.

Cable Clamps for SBS®75X with Integral Handle

Rugged chemical resistant PBT/ PC plastic cable clamps securely hold cables to prevent accidental strain or pulls from dislodging

wire or contacts from the housing. Cable clamps are recommended for solder terminated wires.                        

                                                   Cable Size AWG or             mm² or

Description                                        (Inches O.D.)                 (mm O.D.)                                     ------------------ Part Numbers -------------------

Minimum Quantity  .....................................................................................................        100                                               25  .....

Large Wire Clamp Kit w/ Hardware                   12 to 6 (0.39 to 0.60)        4 to 10 (9.9 to 15.2)                         SBS75XCLP1-BK               SBS75XCLP1

Small Wire Clamp Kit w/ Hardware                   12 to 6 (0.34 to 0.55)        4 to 10 (8.6 to 14.0)                         SBS75XCLP2-BK               SBS75XCLP2

                                                                                                                [ 21.8 ]                      [ 36.4 ]

                                                                                                                         0.86                 1.44

                                                                                                                                                                   The given wire O.D. information is

                                                                                                                                                        [  45.9 ]  an estimate.     Ca