器件描述

控制器 Replacemnt Intgrated Furnace Control

参数
产品属性属性值
制造商:White-Rodgers
产品种类:控制器
发货限制:Mouser目前不销售该产品。
RoHS:详细信息
封装:Bulk
商标:White-Rodgers
产品类型:Controllers
工厂包装数量:10
子类别:Controllers

50A55-743器件文档内容

Single-Stage/HSI Integrated

Furnace Control Kit

OEM Replacement

50A55-743

Replaces:

White-Rodgers 50T55-289 and 50A55-289

and Virtually All Goodman Single-Stage

HSI Controls with 120V Ignitors.

Replace                                              Integrated Furnace

                                                     Module – 50A55-743

the Original

with the Original.

50A55-743 simplifies installation and ensures

peak system performance.

Easy Install Kit includes everything you need

for quick and accurate replacement:

• Ignition Control Module

• Installation Instructions and OEM Cross-Reference
Single-Stage                                                                                                                                                    OEM

HSI Integrated                                                                                                                     Replacement

Furnace Control Kit

Replaces:

White-Rodgers 50T55-289 and 50A55-289 and                                                                                          50A55-743

Virtually All Goodman Single-Stage HSI Controls with 120V Ignitors.

Features                                     Specifications                                                                        Timing Specifications

• 120 VAC Ignitor Output                     Electrical Ratings [@ 77°F (25°C)]                                                    (All times are in seconds unless noted otherwise)

                                             Input Voltage: 25 VAC 50/60 Hz                                                        50A55-743

• 120 VAC Humidifier Output                  Max. Input Current @ 25 VAC: 0.45 amp                                                 Pre-purge:                   15

• 120 VAC Electronic Air Cleaner Output      Relay Load Ratings                                                                    Ignitor warm-up:             7

                                                                                                                                   (1st 64 attempts)

• 120 VAC 2-Speed PSC Circulator Output      Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf                                         Minimum ignitor warm-up:     5

                                             Ignitor Relay: 6.0 amp @ 120 VAC 50/60 Hz (resistive)                                 Maximum ignitor warm-up:     9

• Fuse Protection – 5 Amp                    Inducer Relay: 2.2 FLA–3.5 LRA @ 120 VAC                                              Ignition activation period:  2

                                                                                                                                   Trial for ignition period:   4

• Furnace Status LED                         Circulator Relay: 14.5 FLA–25.0 LRA @ 120 VAC                                         Retries:                     2 times

                                             Flame Current Requirements                                                            Valve sequence period:       12

• Heat Fan OFF Delay (Dipswitch Selectable)                                                                                        Interpurge:                  30

• Y, W, R, G, C, TWIN Terminals              Minimum current to insure flame detection: 1 µa DC*                                   Post-purge                   15

                                             Maximum current for non-detection: 0.1 µa DC*                                         Lockout time                 300

                                             Maximum allowable leakage resistance: 100 M ohms                                      Heat delay to fan ON         30

                                                                                                                                   Heat delay to fan OFF*       90/120/150/180

50A55-743 Cross Reference                    *Measured with a DC microammeter in the flame probe lead                              Cool delay to fan ON         5

                                             Operating Temperature Range                                                           Cool delay to fan OFF        45

50A55-743 Replaces:                                                                                                                Auto reset                   60 minutes

Goodman               White-Rodgers          -40° to 175°F (-40° to 80°C)                                                          Humidifier                   Yes

0130F00005           50A55-289               Humidity Range                                                                        Electronic air cleaner       Yes

0130F00005S          50A55-743               5% to 93% relative humidity (non-condensing)                                          * These times will vary depending on option

B1809926             50T55-289                                                                                                     switch position. See OPERATION section for

B1809926S                                                                                                                          further information.

PCBBF110                                     Mounting

PCBBF110S                                    Surface mount multipoise

PCBBF112

PCBBF112S                                    Timing Specifications (@ 60 Hz**)

PCBBF123

PCBBF123S                                                                         Maximum

NOTE: Can also use Universal Kit 50M56U-843  Flame Establishing Time:             0.8 sec

                                             Flame Failure Response Time:         2.0 sec

                                             **At 50 Hz, all timing specifications should be increased by 20%

                                             Gases Approved: Natural, Manufactured, Mixed,

                                             Liquified Petroleum and LP Gas Air Mixtures are

                                             all approved for use.

                                             Dimensions

                                             4.375" W x 5.875" H x 1.25" D

                                             For Additional Information

                                             Visit www.white-rodgers.com

                                             Saint Louis, Missouri  Markham, Ontario

                                             314-553-3600           905-948-3411

                                             www.white-rodgers.com                         The Emerson logo is a trademark and

                                             www.emersonclimate.com                        a service mark of Emerson Electric Co.                                                     WR-8272-E
Mouser Electronics

Authorized Distributor