电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

3G2C7-LK201-EV1

器件型号:3G2C7-LK201-EV1
器件类别:热门应用    机电/工控/自动化   
文件大小:12397.69KB,共18页
厂商名称:All Sensors
下载文档

器件描述

控制器 rs232 host link mod

参数
制造商: Omron
产品种类: 控制器
RoHS:

3G2C7-LK201-EV1器件文档内容

FA Integrated Tool Package CX-One

CX-Programmer Ver.8

                                                                                                                                                                     CSM_CX-Programmer_Ver8_DS_E_1_1

Improve Productivity for SYSMAC
PLCs from Ladder Program
Development and Unit Setup to
Debugging and Maintenance

Application software to create and debug programs for
  SYSMAC CS/CJ/CP/NSJ-series, C-series, and
  CVM1/C-series CPU Units.

Features

Easily Achieve Position Control with Wading Through User Manuals.
Complete Support for Synchronous Operation between Units.
Easier Connection to PLCs.
Batch Backup/Restore with a Computer.
Comprehensive Programming Environment.
High Program Readability.
Time Required for Onsite Startup and Debugging Has Been Significantly Reduced.

                                                                                   1
                                                                                                       CX-Programmer Ver.8

Ordering Information

International Standards
The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division

    2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
Contact your OMRON representative for further details and applicable conditions for these standards.

Support Software                           Specifications

        Product name                                                                   Number of       Media   Model           Standards
                                                                                        licenses

                    The CX-One is a package that integrates the Support Software                       CD CXONE-AL01C-V3
                    for OMRON PLCs and components. CX-One runs on the

FA Integrated Tool  following OS.                                                      1 license *1                                -
Package
CX-One Ver.3.@      Windows 2000 (Service Pack 3 or higher), XP, or Vista                              DVD     CXONE-AL01D-V3
                    CX-One Ver.3.@ includes CX-Programmer Ver.8.@.                                      *2
                    For details, refer to the CX-One catalog (Cat. No. R134).

                    CX-Programmer can still be ordered individually in the following model numbers.

                                                                                       1 licenses      CD WS02-CXPC1-V8            -
                                                                                       3 licenses
CX-Programmer       PLC programming software                                           10 licenses     CD WS02-CXPC1-V8L03         -
Ver.8.@             OS: Windows 2000 (Service Pack 3 or higher), XP, or Vista

                                                                                                       CD WS02-CXPC1-V8L10         -

*1. Multi licenses are available for the CX-One (3, 10, 30, or 50 licenses).
*2. When purchasing the DVD format, verify the computer model and DVD drive specifications before purchasing.

Support Software (Micro PLC Edition)

                                           Specifications

Product name                                                                           Number of       Media   Model           Standards
                                                                                        licenses                                     -
Micro PLC Edition   PLC Support Software                                                               CD WS02-CXPC2-V8
CX-Programmer       OS: Windows 2000 (Service Pack 3 or higher), XP, or Vista           1 licence
Ver.8.@             Applicable models: CP1L, CP1H, CPM@@, SRM1

Connecting Cables for CX-Programmer                                                    Applicable      Cable   Model           Standards
                                                                                       computers       length
                                                   Product name

                                                                                                       0.1m    CS1W-CN118      CE

                                                                                                       2m      CS1W-CN226      CE

Programming Device Connecting Cables for
Peripheral Port

                                                                                                       6m      CS1W-CN626      CE

                                                                                                       3.3m    CQM1-CIF02      U, C, N, L,
                                                                                                                               CE

                                                                                  IBM PC/AT or         2m      XW2Z-200P-V         -

SYSMAC Host Link Cables (RS-232C cables                                           compatible
that are compatible with Programmable
Controllers)                                                                      computers, D-Sub 9-

                                                                                  pin                  5m      XW2Z-500P-V         -

                                                                                                       2m      XW2Z-200S-CV

                                                                                                       2m      XW2Z-200S-V            -

Programming Device Connecting Cables for                                                               5m      XW2Z-500S-CV           -
RS-232C Port                                                                                                                          -
                                                                                                       5m      XW2Z-500S-V     N
USB-Serial Conversion Cable and PC driver
(on a CD-ROM disk)                                                                IBM PC/AT or                 CS1W-CIF31
Complies with USB Specification 1.1.                                              compatible computer 0.5m
                                                                                  (USB port)

                                                                                                                                                                   2
                                                                             CX-Programmer Ver.8

                                                  Product name   Applicable  Cable   Model            Standards
Programming Console Connecting Cable                             computers   length                  CE

Connecting Cable for peripheral and                                    -     0.05m CS1W-CN114
RS-232C port
                                                                 -           0.1m    CPM2C-CN111     CE
Peripheral interface Unit
                                                                 -           3.3m    C200H-IP007         -

Connecting Cable for peripheral port                             -           6m      CV500-CIF01         -
RS-232C Adapter
                                                                 -               -   CPM1-CIF01      U, C, N, L,
                                                                                                     CE

Peripheral/RS-232C Adapter Unit                                  -               -   CPM2C-CIF01-V1  U, C, CE

RS-422/RS-232C Adapter Unit                                      -               -   CPM2C-CIF11     U, C, CE

Simple Communications Unit                                       -|              -   CPM2C-CIF21     U, C, CE

Note: For information on confirmations of the CX-Programmer, Connecting Cables, and PLCs, refer to Applicable Peripheral Devices in this
        datasheet.

Product Configuration

Setup disk : (CD) CD 1 piece in the case
Guidance : A4 size, English/Japanese
User license agreement/User registration card, English/Japanese

                                                                                                                                          3
                                                                   CX-Programmer Ver.8

Main Functions

                             Category                                                                                          Function
                                                                   Create Ladder program on Ladder View
                                     Ladder                        Create Function Block Call on Ladder View
                                     Structured Text (ST)          Create Rung Comment on Ladder View
                                     SFC                           Create Symbol Comments on Ladder View
                                     Function Block (FB)           Create Attached Comment on Ladder View
Programming                                                        Create Ladder program on Mnemonic View
                                                                   Create Program in Structured Text language
                                     Common                        Create Program in SFC
                                                                   Create SFC Action program in Ladder or Structured Text language
Reuse of program                                                   Create SFC Transition program in Ladder or Structured Text language
                                     Connection with PLC directly  Create Function Block Body in Ladder or Structured Text language
                                                                   Nesting Function Blocks (Up to 8 nesting levels)
Connection with PLC  Connection with PLC on                        Nesting Tree View (FB Instance Viewer)
                     Network                                       Convert Ladder program to Function Block
                                                                   Cross Reference Report
                                       Simulator                   Cross Reference Pop-up
                                                                   Program check
File memory operation                                             Symbol programming
                                                                   Symbol check
*1. Ladder Support Software                                        Delete Unused Symbols
*2. SYSMAC Support Software                                        Address automatic allocation
*3. CV Support Software                                            CX-Programmer configuration function (Option)
*4. SYSMAC-CPT                                                     Keyboard Mapping function
                                                                   Printing function
                                                                   Find/Replace
                                                                   Jump (Set Rung No./Program address/Set Rung with Commented Rung)
                                                                   Expansion advanced instructions (C series)
                                                                   UM area allocation (Set expansion fixed DM) (C200HS/E/G/X, CPM1/CPM1A, CPM2@)
                                                                   Rung wrap function of Ladder (Online)
                                                                   Edit IO comments function
                                                                   Section/Rung manage
                                                                   ROM Writer function
                                                                   Start The CX-Integrator (CS/CJ series)
                                                                   Import old support software data (LSS *1, SSS *2, CVSS *3, CPT *4, SYSWIN data)
                                                                   Import/Export reusable Symbol and Ladder Rung data file
                                                                   C500/C120/C**P backup
                                                                   PLC Backup Tool Operation (Backup/Compare/Restore)
                                                                   Memory Cassette Transfer function/Data Memory to Flash Memory Backup function (CP series)
                                                                   PLC Model conversion
                                                                   Communication with PLC directly
                                                                   Auto Online to a PLC
                                                                   Auto Online - EtherNet/IP Node Online
                                                                   Communication with PLC on Network
                                                                   Ethernet Connection Using UDP/IP
                                                                   Ethernet Connection Using TCP/IP
                                                                   Connecting Using EtherNet/IP
                                                                   Connecting Using Controller Link Network Service Board
                                                                   Connecting Using SYSMAC LINK Network Service Board
                                                                   Connecting Using SYSMAC NET Network Service Board
                                                                   Communication via modem
                                                                   Communication to Simulator
                                                                   Format Memory card
                                                                   Format EM file memory
                                                                   Transfer Program file, Data file, and Parameter file between CPU unit and File memory
                                                                   Transfer Symbol Files and Comment Files between CX-Programmer and File Memory
                                                                   Delete file
                                                                   Transfer (Copy) files between storages

                                                                                                                                                              4
                             Category                                     CX-Programmer Ver.8

IO Table                                                                                           Function
Transfer program                       Create, Edit, Check IO Table
Monitoring program                     Verify/Compare IO Tables
                                       Delete IO Table
Debug program                          Installing a CPS File (CS/CJ series)
                                       Display/Write unit production information, unit text (CS/CJ series)
Simulation                             Display unit profile information (CS/CJ series)
Edit/Monitor IO memory (Data memory)   Set/Transfer/Compare Parameters for Special I/O Units and CPU Bus Units
PLC settings                           Save Parameters for SIOU Units and CPU Bus Units (CS/CJ series)
                                       Start Special Tool for SIOU Units and CPU Bus Units (CSCJ series)
                                       Display each rack's power consumption (CS/CJ series)
                                       Display rack width (CJ series)
                                       Printing function
                                       Display the Dip-switches status of the CPU Unit
                                       Transfer program (Program, Rung Comment, Attached Comment, IO Table, PLC Settings, Symbol
                                       Table, IO Memory, SIOU Unit Parameters)
                                       Transfering in Task units
                                       Verify program (Program, Function Block Body, SFC action, SFC transition, IO Table, IO Memory,
                                       PLC setting)
                                       Monitoring Ladder View
                                       Monitoring Mnemonic View
                                       Monitoring Structured Text program
                                       Monitoring SFC program
                                       Monitoring SFC action, SFC transition, SFC subchart
                                       Displaying Flash-ROM back up status
                                       Monitoring Function Block Ladder View
                                       Monitoring Function Block ST View
                                       Set/Reset
                                       Change current value
                                       Force Set/Reset
                                       Change Timer/Counter setting values
                                       Differential monitor/Pause monitor
                                       Online edit
                                       Online editing of Function Block
                                       Display errors and error logs occurring
                                       Data trace, Time chart monitor
                                       Save result of data trace or time chart monitor
                                       Display cycle time/ task execution time
                                       Measure MARK instruction execution time (CV/CVM1 series)
                                       Read Protection Using Passwords (CS/CJ/CP series)
                                       Read Protection for Specific Tasks (CS/CJ/CP series)
                                       System or partial protection (CV/CVM1 series)
                                       Write Protection (CPM1/CPM1A, CPM2@)
                                       Password Protection of Function Bloks
                                       Read/Set clock
                                       Debugging by using a Simulator
                                       PLC-PT Integrated Simulation
                                       PLC Error Simulator
                                       Edit IO memory data
                                       Monitor IO memory data (PLC Memory window, Address monitor, Watch window, Ladder window,
                                       Mnemonic window)
                                       Verify/Transfer IO memory data
                                       Find contacts of Force set/reset
                                       Edit PLC settings
                                       Transfer PLC settings
                                       Verify PLC settings
                                       Printing

                                                                                                                                       5
                             Category                                                   CX-Programmer Ver.8

                                     File extension                                                              Function
Appendix
                                                     CX-Programmer project file (.CXP); A file containing the all user programs and parameter data
                                     View            created by CX-Programmer. (The .CXP file is a compressed version of the .CXT file.)
                                                     CXT file (.CXT); A text-based format supported by CX-Programmer. The .CXT file format is used for
                                                     file conversions.
                                                     BAK file (.BAK); A backup copy of the project file.
                                                     Program file (.OBJ); It indicates full program area files.
                                                     Program index file (PROGRAMS.IDX); CX-Programmer section names, section comments, and
                                                     program comments.
                                                     Symbols file (SYMBOLS.SYM); CX-Programmer Global symbol tables, Local symbol tables, settings
                                                     for automatically allocated areas.
                                                     Comment file (COMMENTS.CMT); CX-Programmer rung comments and comments.
                                                     OPT file (.OPT); A file containing the preferences for the project.
                                                     CXO file (.CXO); A file containing the settings made on the Options dialog and the Watch window.
                                                     MAC file (.MAC); A file containing the keyboard mapping made on the Keyboard Mapping (Shortcut
                                                     Keys) dialog.
                                                     CX-Server file (.CDM); A file containing all of the information about the PLCs, which CX-Server can
                                                     connect to and the addresses of interest in each PLC which may be accessed. A new CX-Server
                                                     project can be created from the CX-Net Network Configuration tool.
                                                     Ladder Section Window; It displays the Ladder program graphically. PLC program instructions can
                                                     be entered as a graphical representation in Ladder form.
                                                     Output Window;
                                                       [Compile]; The Compile tab displays the output produced from program compilation. Selecting an

                                                        error highlights the source of the problem in the Ladder Diagram. The Compile tab also displays
                                                        other information, for example, warnings and connection messages.
                                                       [Find Report]; The Find Report tab displays the output produced from a search of project files for
                                                        a articular entry.
                                                       [Transfer]; The Transfer tab view displays the results of file or program loading.
                                                     Watch Window; It displays the value of the addresses of PLC memory during program execution.
                                                     Mnemonics View; The Mnemonics view is a formatted editor for programming in mnemonic
                                                     instructions.
                                                     ST Editor Window; Displays the ST language can be input directly.
                                                     SFC Editor Window; Displays an SFC chart or subchart.
                                                     Symbol Table Window; Displays an editable list of symbol definitions - the names, addresses and
                                                     comments.

                                                                                                                                                            6
                                                                                                      CX-Programmer Ver.8

System Requirements

            Item                                                                Requirement

Operating system (OS) *1     Microsoft Windows 2000 (Service Pack 3 or higher) or XP Microsoft Windows Vista *4
Japanese or English system

Computer                     IBM PC/AT or compatible with a Pentium II 333 MHz  IBM PC/AT or compatible with a processor recommended
                             or faster processor (Pentium III 1 GHz or faster   by Microsoft. (1 GHz or faster recommended)
                             recommended.)

Memory                       256 MB minimum *2                                  512 MB min. required.1 GB min. recommended.

Hard disk                    Approx. 2.5 GB or more available space is required to install the complete CX-One package.

Display                      SVGA (800 600) or better high-resolution display with 256 colors min.

Disk drive                   CD-ROM drive or DVD-ROM drive

Communications ports         RS-232C port, USB port, or Ethernet port *3

Other                        Internet access is required for online user registration, including a modem or other hardware connection method.

*1. CX-One Operating System Precaution
     System requirements and hard disk space may vary with the system environment.

*2. The amount of memory required varies with the Support Software used in CX-One for the following Support Software. Refer to user
     documentation for individual Support Software for details.
     CX-Programmer, CX-Designer, CX-Thermo, CX-Simulator, CX-Protocol, CX-Motion, CX-Drive, CX-Process Tool, and Faceplate Auto-Builder
     for NS

*3. An RS-232C port is required to connect the Support Software in CX-One to a PLC. If the computer provides only a USB port, use a CS1W-
     CIF31 USB-to-RS-232C Conversion Cable. For connecting to the CP Series, however, an over-the-counter USB cable (type A-B) can be used.
     For the CX-Drive, the CS1W-CIF31 USB-to-RS-232C Conversion Cable cannot be used to connect a USB port on the computer to the 3G3MV.
     Use the recommended commercially available USB-serial conversion cable.
     For details, refer to the CX-Drive Programmable Controller Operation Manual (Cat. No. W453).

*4. The following restrictions apply when CX-One is used with Microsoft Windows Vista.
     1) Some Help files cannot be accessed.
        The Help files can be accessed if the Help program distributed by Microsoft for Windows Vista (WinHlp32.exe) is installed. Refer to the
        Microsoft homepage listed below or contact Microsoft for details on installing the file. (The download page is automatically displayed if the
        Help files are opened while the user is connected to the Internet.)
        http://support.microsoft.com/kb/917607/en-us
     2) The following restrictions apply to some application operations.

                Application                                                                           Restriction
       CX-Designer
       CX-Process            If a new Windows Vista font (e.g., Meiryo) is used in a project, the font size on labels may be bigger and protrude from the
                             components if the project is transferred from CX-Designer running on a Windows XP or earlier OS to the NS/NSJ.

                             When File Active Serial Port Driver is selected, a message stating that FinsGateway initialization failed may be displayed
                             and the serial driver may not be initialized.

                                                                                                                                                           7
                                                                               CX-Programmer Ver.8
Applicable PLC Series

CX-Programmer can be used with SYSMAC CS/CJ/CP/NSJ-series, C-series, and CVM1/C-series PLCs.

Applicable CPU Units

           Series                                                                                        CPU Unit

CS                 CS1H-CPU63/64/65/66/67 (-V1)
                   CS1G-CPU42/43/44/45 (-V1)
CJ                 CS1H-CPU63H/64H/65H/66H/67H
                   CS1G-CPU42H/43H/44H/45H
CP                 CS1D-CPU65H/67H
                   CS1D-CPU42S/44S/65S/67S
NSJ
                   CJ1G-CPU44/45
C1000H             CJ1H-CPU65H/66H/67H/64H-R/65H-R/66H-R/67H-R
C2000H             CJ1G-CPU42H/43H/44H/45H
C200H              CJ1M-CPU11/12/13/21/22/23
C200HX             CJ2H-CPU64-EIP/65-EIP/66-EIP/67-EIP/68-EIP
C200HG             CJ2H-CPU64/65/66/67/68
C200HE
C200HX-Z           CP1H-XA40DR-A/XA40DT-D/XA40DT1-D/X40DR-A/X40DT-D/X40DT1-D/Y20DT-D
C200HG-Z           CP1L-M40DR-A/M40DR-D/M40DT-D/M40DT1-D/M30DR-A/M30DR-D/M30DT-D/M30DT1-D/M60DR-A/M60DR-D
C200HE-Z
C200HS                     /M60DT-D/M60DT1-D
CPM1/CPM1A         CP1L-L20DR-A/L20DR-D/L20DT-D/L20DT1-D/L14DR-A/L14DR-D/L14DT-D/L14DT1-D/L10DR-A/L10DR-D/L10DT-D
CPM2@
CPM2@-S@                   /L10DT1-D
CQM1
CQM1H              NSJ5-@-G5D
CV1000             NSJ8-@-G5D
CV2000             NSJ10-@-G5D
CV500              NSJ12-@-G5D
CVM1               NSJ5-@-M3D
CVM1-V2            NSJ8-@-M3D
FQM1
IDSC               C1000H-CPU01
SRM1
                   C2000H-CPU01 Simplex system

                   C200H-CPU01/02/03/11/21/22/23/31

                   C200HX-CPU34/44/54/64

                   C200HG-CPU33/43/53/63

                   C200HE-CPU11/32/42

                   C200HX-CPU34-Z/CPU44-Z/CPU54-Z/CPU64-Z/CPU65-Z/CPU85-Z

                   C200HG-CPU33-Z/CPU43-Z/CPU53-Z/CPU63-Z

                   C200HE-CPU11-Z/CPU32-Z/CPU42-Z

                   C200HS-CPU01/03/21/23/31/33

                   CPM1 (A)-10CDR/20CDR/30CDR/40CDR (-V1)

                   CPM2A-20CD/30CD/40CD/60CD
                   CPM2C-10CD/10C1D/20CD/20C1D

                   CPM2C-S100C/110C
                   CPM2C-S110C-DRT

                   CQM1-CPU11/21/41/42/43/44/45

                   CQM1H-CPU11/21/51/61

                   CV1000-CPU01 (-V1)

                   CV2000-CPU01 (-V1)

                   CV500-CPU01 (-V1)

                   CVM1-CPU01/1 (-V1)

                   CVM1-CPU01-V2/CPU11-V2/CPU21-V2

                   FQM1-CM001/CM002 Coordinator module
                   FQM1-MMA21/MMA22/MMP21/MMP22 Motion control module

                   IDSC-C1DR-A/C1DT-A

                   SRM1-C01/C02 (-V1/-V2)

                                                                                                                   8
                                                               CX-Programmer Ver.8

Communication Method to Connect Applicable PLC and PC

Via USB          USB A plug (female)
                 USB B plug (male)
PC
PLC

Via RS-232C      PC built-in RS-232C port

PC              CPU unit built-in peripheral port
                 CPU unit built-in RS-232C port
PLC             Serial communication unil/board RS-232C port

Via Ethernet     Ethernet port, Ethernet Card
                 Ethernet unit, EtherNet/IP Unit
PC
PLC

Via Network Support Board

Controller Link

PC               Controller Link board
PLC              Controller Link unit

SYSMAC LINK      SYSMAC LINK board
                 SYSMAC LINK unit
PC
PLC

SYSNET           SYSNET board
                 SYSNET unit
PC
PLC

                                                                                    9
Applicable Peripheral Devices                                                                                  CX-Programmer Ver.8

Connection Types for PLC and PC (CX-Programmer)                                                                            PC port (CX-Programmer)
                                                                                                        Conversion Cables (PC)
Connection                          PLC Port                               Connecting Cables
   Types                                    Conversion Cables (PLC)

                                                                           Commercially available

A           USB B plug (male)                                           -  USB cable (A plug            -             USB A plug (female)
                                                                           connector (male) - B plug

                                                                           connector (female))

                                                                                              XW2Z-@@@  CS1W-CIF31 *
                                                                        -
B           D-sub, 9-pin (female)                                                                                     USB A plug (female)

                                                                           XW2Z-@@@P-V                  CS1W-CIF31 *

C           D-sub, 25-pin (female)                                      -                                             USB A plug (female)

                                                                           CQM1-CIF02

            C Series peripheral                                         -

                                                            CPM1-CIF01                                  CS1W-CIF31 *
D
                                                                                                                      USB A plug (female)
                   CPM1, CPM1A, CPM2A,
                   SRM1                                                    XW2Z-@@@S-V/S-CV

                                                                           CV500-CIF01

                                                                                                        CS1W-CIF31 *

E           CV Series peripheral                                        -                                             USB A plug (female)
                                                                                                                      USB A plug (female)
                                                                        -  CS1W-CN226/
                                                                           CS1W-CN626
            CS/CJ/CP/CQM1H          CS1W-CN118                                                          CS1W-CIF31 *
            peripheral                                                     XW2Z-@@@S-V/S-CV
F

                                    CS1W-CN114                             CQM1-CIF02

* The CS1W-CIF31 is not required if the connector on the computer running the CX-Programmer has a D-sub, 9-pin male connector.
Note: 1. PC (Personal Computer) : IBM PC/AT or compatible computer

        2. A Host Link Unit (e.g., C200H-LK201-V1) or Peripheral Interface Unit (C200H-IP007) is required for some PLCs. Refer to the tables for
            individual PLCs for details.

                                                                                                                                                    10
                                                                       CX-Programmer Ver.8

Connection         PLC Port                         Connecting Cables                     PC port (CX-Programmer)
   Types                   Conversion Cables (PLC)                     Conversion Cables (PC)

                                         CS1W-CN226/
                                         CS1W-CN626
                   -

                   CPM2C-CN111

                   CS1W-CN114                       CQM1-CIF02
                   CS1W-CN114
                   +CPM2C-CIF01-V1

                   CPM2C-CN111

                                                                       CS1W-CIF31 *

G           CPM2C  CS1W-CN118                                                        USB A plug (female)
                   CS1W-CN118
                   +CPM2C-CIF01-V1                  XW2Z-@@@

                   CPM2C-CIF01-V1

                   CPM2C-CIF11

                                                             CPM2C-CIF21

* The CS1W-CIF31 is not required if the connector on the computer running the CX-Programmer has a D-sub, 9-pin male connector.
Note: 1. PC (Personal Computer) : IBM PC/AT or compatible computer

        2. A Host Link Unit (e.g., C200H-LK201-V1) or Peripheral Interface Unit (C200H-IP007) is required for some PLCs. Refer to the tables for
            individual PLCs for details.

                                                                                                                                                  11
                                                                                                            CX-Programmer Ver.8

Connecting Cables for PLCs and PCs (CX-Programmer)

Conversion Cables for USB-D-Sub 9-pin

             Unit                                       Computer             Network Type (Serial           Model                Cable length  Connection
                          Unit port                               PC port  Communications Mode)                                                   Types

          -  RS-232C                 PC/AT              USB A plug         Depends on the Unit's            CS1W-CIF31           0.5m                    -

             D-sub, 9-pin (female) compatible connector (female) spcifications.

Connecting Cables for CJ2

             Unit                                       Computer             Network Type (Serial           Model                Cable length  Connection
                          Unit port                               PC port  Communications Mode)                                                   Types

             USB B plug                                 USB A plug         USB or                           Commercially         5m maximum A
             connector (male)                                                                               available USB cable  5m
                                     PC/AT              connector (female) Toolbu (USB port)                (A plug connector
                                     compatible                                                             (male) - B plug                           B
CPU Unit                                                                                                    connector (female))  2m

             Built-in RS-232C port                      D-sub, 9-pin (male) Host Link                       XW2Z-500S-CV
             D-sub, 9-pin (female)                                                                          XW2Z-200S-CV

Connecting Cables for CS1/CJ1

             Unit                                       Computer             Network Type (Serial           Model                Cable length  Connection
                          Unit port                               PC port  Communications Mode)                                                   Types

                                                                                                            CS1W-CN226           2m
                                                                                                                                 6m
                                                                                                            CS1W-CN626
                                                                           Peripheral bus or Host                                0.1m+2m
                                                                           Link                             CS1W-CN118
                                                                                                            +XW2Z-200S-CV

             Built-in peripheral                                                                            CS1W-CN118           0.1m+5m
             port                                                                                           +XW2Z-500S-CV                             F

                                                                                                            CS1W-CN118           0.1m+2m
                                                                                                            +XW2Z-200S-V
CPU                                  PC/AT              D-sub, 9-pin (male) Host Link
                                     compatible                                                             CS1W-CN118
                                                                                                            +XW2Z-500S-V         0.1m+5m

                                                                           Host Link with a baud rate CS1W-CN114                 0.05m+3.3m

                                                                           of 19.2 kbps or less             +CQM1-CIF02          2m
                                                                                                                                 5m
             Built-in RS-232C port                                         Peripheral bus or Host           XW2Z-200S-CV
             D-sub, 9-pin (female)                                         Link                             XW2Z-500S-CV                              B
                                                                                                            XW2Z-200S-V          2m
                                                                           Host Link                        XW2Z-500S-V          5m

Connecting Cables for CP1H/CP1L

             Unit                                       Computer             Network Type (Serial           Model                Cable length  Connection
                          Unit port                               PC port  Communications Mode)                                                   Types

             USB B plug                                 USB A plug         USB                              Commercially         5m maximum A
             connector (male)                           connector (male)                                    available USB cable
                                                                                                            (A plug connector    2m
CPU                                  PC/AT                                          Peripheral bus or Host  (male) - B plug      5m
                                     compatible                                     Link                    connector (female))
             RS-232C port (D-sub                        D-sub, 9-pin (male)                                                                           B
             9-pin female) on                                                                               XW2Z-200S-CV         2m
             Option Board                                                           Host Link                                    5m
             D-sub, 9-pin (female)                                                                          XW2Z-500S-CV

                                                                                                            XW2Z-200S-V

                                                                                                            XW2Z-500S-V

* An Option Board cannot be used with a CP1L CPU Unit with 10 Points.

Connecting Cables for NSJ

             Unit                                       Computer             Network Type (Serial           Model                Cable length  Connection
                          Unit port                               PC port  Communications Mode)                                                   Types

             USB B plug                                 USB A plug         USB                              Commercially         5m maximum A
             connector (male)                           connector (male)                                    available USB cable
                                                                                                            (A plug connector    2m
CPU                                         PC/AT                                   Peripheral bus or Host  (male) - B plug      5m
                                            compatible                              Link                    connector (female))
                                                        D-sub, 9-pin (male)                                                                           B
             Built-in RS-232C port                                                                          XW2Z-200S-CV         2m
             D-sub, 9-pin (female)                                                  Host Link                                    5m
                                                                                                            XW2Z-500S-CV

                                                                                                            XW2Z-200S-V

                                                                                                            XW2Z-500S-V

                                                                                                                                                            12
                                                                                                         CX-Programmer Ver.8

Connecting Cables for C200HS

                Unit                                      Computer               Network Type (Serial    Model          Cable length  Connection
                             Unit port                              PC port    Communications Mode)                                      Types

                       Built-in peripheral                                     Peripheral bus or Host    CQM1-CIF02     3.3m          D
                       port                                                    Link

CPU Unit               Built-in RS-232C port                                                             XW2Z-200S-CV   2m
                       D-sub, 9-pin (female)                                                             XW2Z-500S-CV   5m
                       (CPU 21/23/31/33       PC/AT       D-sub, 9-pin (male)                            XW2Z-200S-V
                       only)                  compatible                              Host Link          XW2Z-500S-V                         B
                                                                                                                        2m
Host Link Unit C200H-  Built-in RS-232C port                                                             XW2Z-200P-V    5m
LK201-V1               D-sub, 25-pin                                                                     XW2Z-500P-V    2m
                       (female)
                                                                                                                                             C
                                                                                                                        5m

Connecting Cables for C200HX/HG/HE

                Unit                                      Computer               Network Type (Serial    Model          Cable length  Connection
                             Unit port                              PC port    Communications Mode)                                      Types

                       Built-in peripheral                                     Peripheral bus * or Host  CQM1-CIF02     3.3m          D
                       port                                                    Link

                                                                                                         XW2Z-200S-CV   2m

CPU                    Built-in RS-232C port                                                             XW2Z-500S-CV   5m
                       D-sub, 9-pin (female)
                                              PC/AT       D-sub, 9-pin (male)                            XW2Z-200S-V    2m            B
                                              compatible
                                                                               Host Link
                                                                                                         XW2Z-500S-V    5m

Host Link Unit         Built-in RS-232C port                                                             XW2Z-200P-V *  2m
C200H-LK201-V1         D-sub, 25-pin
                       (female)                                                                          XW2Z-500P-V *  5m            C

* These Cables cannot be used for Programming Devices, such as the CX-Programmer, for the C200H-LK201-V1 Host Link Unit on a C200HX/
  HG/HE-Z PLC.

Connecting Cables for CQM1H

                Unit                                      Computer               Network Type (Serial    Model          Cable length  Connection
                             Unit port                              PC port    Communications Mode)                                      Types

                                                                                                         CS1W-CN226     2m
                                                                                                                        6m
                                                                                                         CS1W-CN626

                                                                                                         CS1W-CN114     0.05m+3.3m
                                                                                                         +CQM1-CIF02

                       Built-in peripheral                                     Peripheral bus or Host    CS1W-CN118     0.1m+2m
                       port                                                    Link                      +XW2Z-200S-CV                       F

                                                                                                         CS1W-CN118     0.1m+5m
                                                                                                         +XW2Z-500S-CV
CPU                                           PC/AT       D-sub, 9-pin (male)
                                              compatible                                                 CS1W-CN118
                                                                                                         +XW2Z-200S-V   0.1m+2m

                                                                                                         CS1W-CN118     0.1m+5m
                                                                                                         +XW2Z-500S-V
                                                                                                                        2m
                                                                                                         XW2Z-200S-CV   5m

                       Built-in RS-232C port                                   Host Link                 XW2Z-500S-CV                        B
                       D-sub, 9-pin (female)                                                             XW2Z-200S-V    2m
                                                                                                                        5m
                                                                                                         XW2Z-500S-V

Connecting Cables for CQM1

                Unit                                      Computer               Network Type (Serial    Model          Cable length  Connection
                             Unit port                              PC port    Communications Mode)                                      Types

                       Built-in peripheral                                     Peripheral bus or Host    CQM1-CIF02     3.3m          D
                       port                                                    Link

CPU                    Built-in RS-232C port  PC/AT       D-sub, 9-pin (male)                            XW2Z-200S-CV   2m
                       D-sub, 9-pin (female)  compatible                              Host Link          XW2Z-500S-CV   5m
                       (CPU42/43/44/63/64/                                                               XW2Z-200S-V
                       65/85 only)                                                                       XW2Z-500S-V                         B
                                                                                                                        2m
                                                                                                                        5m

                                                                                                                                                  13
                                                                                           CX-Programmer Ver.8

Connecting Cables for CPM1, CPM1A and CPM2A

          Unit                                Computer               Network Type (Serial  Model          Cable length  Connection
                       Unit port                        PC port    Communications Mode)                                    Types

                                                                   Peripheral bus or Host  CPM1-CIF01     2m
                                                                                           +XW2Z-200S-CV

          Built-in peripheral     PC/AT                                   Link             CPM1-CIF01     5m
          port                    compatible  D-sub, 9-pin (male)                          +XW2Z-500S-CV
CPU Unit                                                                                                                D
                                                                                           CPM1-CIF01
                                                                                           +XW2Z-200S-V   2m

                                                                   Host Link               CPM1-CIF01
                                                                                           +XW2Z-500S-V
                                                                                                          5m

* CPM2A CPU Units that have a 9 as the fourth digit of the lot number (4 or 5 digits) do not support Toolbus connections. They do support Host
  Link connections.

Connecting Cables for SRM1

          Unit                                Computer               Network Type (Serial  Model          Cable length  Connection
                       Unit port                        PC port    Communications Mode)                                    Types

                                                                   Peripheral bus or Host  CPM1-CIF01     2m
                                                                   Link                    +XW2Z-200S-CV
                                                                                                          5m
          Built-in peripheral                                                              CPM1-CIF01                          D
          port                                                                             +XW2Z-500S-CV
                                                                                                          2m
                                                                                           CPM1-CIF01
CPU Unit                          PC/AT       D-sub, 9-pin (male)                          +XW2Z-200S-V   5m
                                  compatible
                                                                                           CPM1-CIF01     2m
                                                                   Host Link               +XW2Z-500S-V   5m

          Built-in RS-232C port                                                            XW2Z-200S-CV                        B
          D-sub, 9-pin (female)                                                                           2m
          (SRM1-C01 only)                                                                  XW2Z-500S-CV   5m

                                                                                           XW2Z-200S-V

                                                                                           XW2Z-500S-V

                                                                                                                                                14
                                                                                         CX-Programmer Ver.8

Connecting Cables for CPM2C

     Unit                                Computer               Network Type (Serial     Model              Cable length  Connection
                  Unit port                        PC port    Communications Mode)                                           Types

                                                                                         CS1W-CN226 *2      2m

                                                                                         CS1W-CN626 *2      6m

     Communications port                                      Peripheral bus *1 or Host  CS1W-CN114         0.05m+3.3m
     (as a peripheral port)                                   Link                       +CQM1-CIF02
                                                                                                            Adapter+
                                                                                         CPM2C-CIF01-V1     0.05m + 3.3m
                                                                                         +CS1W-CN114
                                                                                         +CQM1-CIF02

                                                                                         CPM2C-CN111        0.1m+3.3m
                                                                                         (Peripheral port)
                                                                                         +CQM1-CIF02

                                                                                         CS1W-CN118         0.1m+2m
                                                                                         +XW2Z-200S-CV

                                                                                         CS1W-CN118         0.1m+5m
                                                                                         +XW2Z-500S-CV

                                                                                         CPM2C-CN111        0.1m+2m
                                                                                         (RS-232C port)
                                                                                         +XW2Z-200S-CV

                                                                                         CPM2C-CN111        0.1m+5m
                                                                                         (RS-232C port)
                                                                                         +XW2Z-500S-CV

                                                                                         CPM2C-CIF01-V1     Adapter+2m
                                                                                         +XW2Z-200S-CV

                                                                                         CPM2C-CIF01-V1     Adapter+5m
                                                                                         +XW2Z-500S-CV

                                                                                         CPM2C-CIF01-V1     Adapter
                                                                                         +CS1W-CN118        0.1m+2m
                                                                                         +XW2Z-200S-CV

CPU                          PC/AT       D-sub, 9-pin (male)                             CPM2C-CIF01-V1     Adapter       G
                             compatible                                                  +CS1W-CN118        0.1m+5m
                                                                                         +XW2Z-500S-CV

                                                                                         CS1W-CN118         0.1m+2m
                                                                                         +XW2Z-200S-V

     Communications port                                      Host Link                  CS1W-CN118         0.1m+5m
     (as an RS-232C port)                                                                +XW2Z-500S-V       0.1m+2m

                                                                                         CS1W-CN111
                                                                                         (RS-232C port)
                                                                                         +XW2Z-200S-V

                                                                                         CS1W-CN111         0.1m+5m
                                                                                         (RS-232C port)
                                                                                         +XW2Z-500S-V

                                                                                         CPM2C-CIF01-V1     Adapter+2m
                                                                                         +XW2Z-200S-V

                                                                                         CPM2C-CIF01-V1     Adapter+5m
                                                                                         +XW2Z-500S-V

                                                                                         CPM2C-CIF01-V1     Adapter+
                                                                                         +CS1W-CN118        0.1m+2m
                                                                                         +XW2Z-200S-V

                                                                                         CPM2C-CIF01-V1     Adapter+
                                                                                         +CS1W-CN118        0.1m+5m
                                                                                         +XW2Z-500S-V

                                                                                         CPM2C-CIF11        Adapter+2m
                                                                                         +XW2Z-200S-V

                                                                                         CPM2C-CIF11        Adapter+5m
                                                                                         +XW2Z-500S-V

                                                                                         CPM2C-CIF21        Adapter+2m
                                                                                         +XW2Z-200S-V

                                                                                         CPM2C-CIF21        Adapter+5m
                                                                                         +XW2Z-500S-V

*1. CPM2C CPU Units that have a 9 as the fourth digit of the lot number (4 or 5 digits) and that were manufactured in 1999 do not support Toolbus
     connections. They do support Host Link connections.

*2. Only Host Link (SYSMAC WAY) connections are possible. Toolbus cannot be used.
Note: Refer to the CPM2C Operation Manual (Cat. No. W340) for details.

                                                                                                                                                   15
                                                                                                       CX-Programmer Ver.8

Connecting Cables for C1000H, C2000H, C200H

                      Unit                                  Computer             Network Type (Serial  Model          Cable length  Connection
                                   Unit port                          PC port  Communications Mode)                                    Types

CPU Unit              Built-in peripheral                                                              C200H-IP007    3.3m          D
                      port                                                                             +CQM1-CIF02

Host Link Unit                                                                                         XW2Z-200P-V    2m
C1000H, C2000H:                                                                                        XW2Z-500P-V
C500-LK203                                           PC/AT  D-sub, 9-pin (male) Host Link
C500-LK201-V1         Built-in RS-232C port compatible
(3G2A5-LK201-V1)      D-sub, 25-pin                                                                                                        C
C120-LK201-V1         (female)                                                                                        5m
(3G2A6-LK201-EV1)
C200H:
C200H-LK201-V1
C120-LK201-V1
(3G2A6-LK201-EV1)

Connecting Cables for CVM1/CV

                      Unit                                  Computer             Network Type (Serial  Model          Cable length  Connection
                                   Unit port                          PC port  Communications Mode)                                    Types

                      Built-in peripheral                                                              CV500-CIF01    6m            E
                      port
CPU Unit                                                                                               XW2Z-200S-V *  2m
                      Built-in RS-232C port                                                            XW2Z-500S-V *                       B
                      D-sub, 9-pin (female)
                                                                                                                      5m
Host Link Unit        Built-in RS-232C port   PC/AT         D-sub, 9-pin (male) Host Link              XW2Z-200P-V
CV500-LK201           D-sub, 25-pin           compatible                                               XW2Z-500P-V    2m
(for full duplex      (female)                                                                                                             C
communication on
port 1)                                                                                                               5m

Host Link Unit        Built-in RS-232C port                                                            XW2Z-200S-V    2m
CV500-LK201           D-sub, 9-pin (female)                                                            XW2Z-500S-V
(for full duplex                                                                                                                           B
communication on                                                                                                      5m
port 2)

* The XW2Z-200S-CV and XW2Z-500S-CV cannot be used.

Connecting Cables for C500

                      Unit                                  Computer             Network Type (Serial  Model          Cable length  Connection
                                   Unit port                          PC port  Communications Mode)                                    Types

CPU Unit *1           Built-in peripheral                                                              C200H-IP007    3.3m          D
                      port                                                                             +CQM1-CIF02

Host Link Unit *2                                    PC/AT                                             XW2Z-200P-V    2m
C500-LK203            Built-in RS-232C port compatible
C500-LK201-V1         D-sub, 25-pin                         D-sub, 9-pin (male) Host Link
(3G2A5-LK201-EV1)     (female)
C120-LK201-V1                                                                                                                       C
(3G2A6-LK201-EV1)
                                                                                                       XW2Z-500P-V    5m

*1. Production of the CPU Units was discontinued in March 2004.
*2. Production of the C500-LK203, C500-LK201-V1 (3G2A5-LK201-EV1), and C120-LK201-V1 (3G2A6-LK201-EV1) was discontinued in March

     2006. (There is no recommended substitute product.)

Connecting Cables for C120

                      Unit                                  Computer             Network Type (Serial  Model          Cable length  Connection
                                   Unit port                          PC port  Communications Mode)                                    Types

CPU Unit *1           Built-in peripheral                                                              C200H-IP007    3.3m          D
                      port                                                                             +CQM1-CIF02
Host Link Unit *2                             PC/AT
C120-LK201-V1         Built-in RS-232C port   compatible    D-sub, 9-pin (male) Host Link              XW2Z-200P-V    2m
(3G2A6-LK201-EV1)     D-sub, 25-pin
                      (female)                                                                         XW2Z-500P-V    5m            C

*1. Production of the CPU Units was discontinued in March 2003.
*2. Production of the C120-LK201-V1 was discontinued in March 2006. (There is no recommended substitute product.)

Connecting Cables for C20P/C28P/C40P/C60P*1, C20K/C28K/C40K/C60K*2

                      Unit                                  Computer             Network Type (Serial  Model          Cable length  Connection
                                   Unit port                          PC port  Communications Mode)                                    Types

Host Link Unit *3 *4  Built-in RS-232C port   PC/AT                                                    XW2Z-200P-V    2m
C20-LK201-V1          D-sub, 25-pin           compatible
                      (female)                              D-sub, 9-pin (male) Host Link              XW2Z-500P-V    5m            C
(3G2C7-LK201-EV1)

*1. Production of the C20P, C28P, C40P, and C60P CPU Units was discontinued in March 2002.
*2. Production of the C20K, C28K, C40K, and C60K CPU Units was discontinued in March 2002.
*3. For connection to C@@P PLCs, a Host Link Unit is also required in addition to a Connecting Cable.
*4. Production of the C20-LK201-V1 (3G2C7-LK201-EV1) was discontinued in March 2006. (There is no recommended substitute product.)

                                                                                                                                                16
                                                           CX-Programmer Ver.8

Related Manuals

   Cat.No.               Model            Manual name                                                          Contents
W446        WS02-CXPC@-V8       CX-Programmer Ver.8.@      Provides information on how to use the CX-Programmer for all functionality except for
                                Operation Manual           function blocks.
W447        WS02-CXPC@-V8       CX-Programmer Ver. 8.@     Describes the function block functions and structured text programming functions that can
                                Operation Manual Function  be used with the CX-Programmer version 8.@. For details on other CX-Programmer
W469        WS02-CXPC@-V8       Blocks/Structured Texts    functions, refer to the CX-Programmer Ver. 8.@ Operation Manual (Cat. No.W446).
W463                                                       Explains how to use the SFC programming functions. For explanations of other shared
W445        CXONE-AL@@C-V3/     CX-Programmer              CX-Programmer functions, refer to the CX-Programmer Operation Manual (W446).
            AL@@D-V3            Operation Manual: SFC
            CXONE-AL@@C-V3/                                Installation and overview of CX-One FA Integrated Tool Package.
            AL@@D-V3            CX-One Setup Manual
                                                           Describes the operating procedures for the CX-Integrator.
                                CX-Integrator
                                Operation Manual

                                                                                                                                                      17
                                                       Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                            Application Considerations

SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

       Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

       Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
           safety equipment, and installations subject to separate industry or government regulations.

       Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                       Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

OMRON Corporation                                                                                                                                        2009.5
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                                                   (c)Copyright OMRON Corporation 2009 All Right Reserved.
http://www.ia.omron.com/
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved