MOTORIZED VRBLE TRANSF 280V 9.5A

参数

产品属性属性值
类型:面板安装
输出类型:端子
电压 - 输出:240VAC,280VAC
电压 - 电源:120VAC, 240VAC
输入类型:端子
恒流负载 - 最大值:9.5A(2.66kVA)
尺寸:8.310" 长 x 7.250" 宽 x 11.550" 高(211.07mm x 184.15mm x 293.37mm)

30M1520器件文档内容

Popular
Variable Transformers
and AC Power Supplies

Product Guide--
AC Voltage Control
Devices                Guide
Guide

www.stacoenergy.com    Your Tailored Power Solutions ProviderTM
Staco Energy Products Co. has been a leading manufacturer of variable      In addition to the basic styles illustrated, Staco Energy can meet your
transformers for over 65 years, building standard and custom-              specific requirements with hundreds of additional standard model
designed products for industrial, commercial and military applications.    variations and configurations from 0.8 to 450 amps, 120 to 575 volts,
Variable transformers have many industrial and laboratory applications     50 Hz and up. 480 volt units are shown on page 8 and in our Variable
as basic components to control voltage, current, power, heat, speed,       Transformer Voltage Control Catalog (VT-5). These models include
light and electromechanical force.                                         cased and uncased, single and three phase manual and motor driven
                                                                           models, and complete voltage control systems. Complete information
A basic Staco variable transformer consists of a single layer magnet       is contained in our Variable Transformer Voltage Control Catalog.
wire winding on a toroidal core of laminated silicon steel. A carbon
brush, connected to an output lead, is rotated over a precision            To serve your needs promptly, Staco Energy has a national network of
ground, plated commutator track to tap off voltage at any turn from        stocking distributors to assure immediate off-the-shelf delivery. Your
zero to the maximum output voltage of the winding.                         local Staco distributors and representatives are factory trained, and
                                                                           capable of assisting you in selecting the particular Staco transformer
Staco research has developed design features and proprietary pro-          best suited for your application.
cesses to provide longer lasting, more reliable products. Particularly
important is the high-temperature foundation material bonding the          Contact our factory or visit the "Where to Buy" section of www.
coil securely to the core assembly. This material has a high thermal       StacoEnergy.com for the name of the distributors or sales representative
transfer characteristic so that it dissipates heat from the brush contact  in your area.
area, increases the heat distribution of the core itself, and provides
the transformer with greater tolerance to transients and short-term        For nonstandard products (to meet your special application needs) our
overloads.                                                                 engineering staff will quickly respond with custom solutions to your
                                                                           application requirements. Often a simple revision to a standard compo-
              Some Models Are                                              nent is all that is required, allowing us to keep your costs at a minimum.
              Listed by the Canadian Standards Association
              File No. LR18948                                             Dimensions are provided throughout this
                                                                           catalog in inches [millimeters].

Panel Mount, Single Phase -- 120 and 240 Volt

Adjustable Shaft

100 and 200 Series                                                                Input         Output
                                                                           Volts Hertz
                                   171, 201    Part No.                                  Volts  Constant       Constant  Net Wt.
                                                                                                 Current      Impedance    Lbs.
                                   221-B, 291                                            0-120
                                                                                         0-132    Load            Load     2
                                                                                         0-120                             2
                                                                                         0-132  Max. Max. Max. Max.        2.5
                                                                                         0-120  Amps. kVA Amps. kVA        2.5
                                                                                         0-132                             2.5
                                                171                        120  50/60    0-120  1.75 0.21 2.2 0.26
                                                201                              60      0-132  1.75 0.23 -- --
                                               221-B                                     0-240  2.0 0.24 2.5 0.30
                                                291                        120  50/60    0-264  2.0 0.26 -- --
                                                252                              60             2.50 0.30 3.2 0.38
                                                                                                2.50 0.30 -- --
                                               Part No.                    120  50/60           3.0 0.36 3.5 0.42
                                                                                 60             3.0 0.40 -- --
                                                                                                0.8 0.19 1.0 0.24
Type        A                                                              120  50/60           0.8 0.21 -- --
171, 201    1.88" (47.6)                                                         60
221-B, 252  2.12" (54.0)
291         2.31" (58.7)                                                   240  50/60
                                                                                 60

500 Series                                                                        Input         Output
                                                                           Volts Hertz
                                                                                         Volts  Constant       Constant  Net Wt.
                                                                                                 Current      Impedance    Lbs.

                                                                                                  Load            Load

                                                                                                Max. Max. Max. Max.
                                                                                                Amps. kVA Amps. kVA

                                               511                         120 50/60     0-120  5.0 0.60 7.0  0.84       4.25
                                                                                         0-140  5.0 0.70 --    --

  Adjustable Shaft                                                                Input         Output
501C Series                                                                Volts Hertz

                                               Part No.                                  Volts  Constant       Constant  Net Wt.
                                                                                                 Current      Impedance    Lbs.
                                               501C
                                                                                                  Load            Load

                                                                                                Max. Max. Max. Max.
                                                                                                Amps. kVA Amps. kVA

                                                                           120  50/60    0-120  5.0 0.60 7.0  0.84       5.25
                                                                                         0-140  5.0 0.70 --    --

            Variable Transformers                                                        www.stacoenergy.com
   Adjustable Shaft                                                                               Input                Output
1000 and 2200 Series                                                                       Volts Hertz
                                                                                                                       Constant      Constant     Net Wt.
                                    1010 & 1210                                                                         Current     Impedance       Lbs.

                                                                     Part No.                            Volts           Load           Load

                                                                    1010B                                        Max. Max. Max. Max.
                                                                    1210B                                        Amps. kVA Amps. kVA
                                                                    1020B
                                                                    1220B                  120 50/60     0-120         10.0 1.20 13.0       1.56  10.25
                                                                                                         0-140         10.0 1.40 --          --

                                                                                           120       60  0-120         12.0 1.44 15.0 1.80 10.25

                                    1020 & 1220                                            240 50/60     0-240         3.5 0.84 5.0 1.20
                                                                                                         0-280
Types 1210B and 1220B                                                                                    0 -280        3.5 0.98 -- -- 10.25
include terminals 1, 3 and 4 only.                                                                       0-240
                                                                                           120 50/60                   3.5* 0.42* -- --
1500 Series
                                                                                           240       60                5.0 1.20 7.0 1.68 10.25
                         1510
                                                                                                  Input                Output
                                                                                           Volts Hertz
                                                                    Part No.                             Volts         Constant      Constant     Net Wt.
                                                                                           120 50/60                    Current     Impedance       Lbs.
                                                                    1510                   240 50/60
                                                                    1520                   120 50/60                     Load           Load

                                                                                                                 Max. Max. Max. Max.
                                                                                                                 Amps. kVA Amps. kVA

                                                                                                         0-120         15.0 1.80 20.0       2.40  15.75
                                                                                                         0-140         15.0 2.10 --          --

                               1520                                                                      0-240         9.5 2.28 12.0 2.88
                                   2510                                                                  0-280
                                                                                                         0-280         9.5 2.66 -- -- 19.25

                                                                                                                       9.5* 1.14* -- --

1510         1520

A 4.25" (108.0) 4.62" (117.3)

2500 Series                                                                                       Input                     Output
                                                                                           Volts Hertz
                                                                    Part No.                             Volts         Constant      Constant     Net Wt.
                                                                                           120 50/60                    Current     Impedance       Lbs.
                                                                    2510                   240 50/60
                                                                    2520                   120 50/60                     Load           Load

                                                                                                                 Max. Max. Max. Max.
                                                                                                                 Amps. kVA Amps. kVA

                                                                                                         0-120 25.0 3.00 30.0 3.60                21
                                                                                                         0-140 25.0 3.50 -- --

                               2520                                                                      0-240 10.0 2.40 13.0 3.12

                                                                                                         0-280 10.0 2.80 -- --                    21

                                                                                                         0-280 10.0* 1.20* -- --

5000 Series                                                                                                     Input               Output
                                                                                                         Volts Hertz
                               5011                                                        Part No.                    Volts          Constant    Net Wt.
                                                                                                         120 50/60                     Current      Lbs.
                                                       5021                                5011          240 50/60
                                                       Single Unit                         5021          120 50/60                       Load

                                                                                                                                     Max. Max.
                                                                                                                                    Amps. kVA

                                                                                                                       0-140 50.0 7.00 57

                                                                                                                       0-240 28.0 6.70
                                                                                                                       0-280 28.0 7.80 57
                                                                                                                       0-280 28.0* 3.40*

6000 Series                                                                                                     Input               Output
                                                                                                         Volts Hertz
*Voltage Doubler operation, refer to Variable Transformer Voltage Control Catalog (VT-5).  Part No.                    Volts          Constant    Net Wt.
                             Data is subject to change without notice.                                   120 50/60                     Current      Lbs.
                                                                                           6011          240 50/60
                                                                                           6020          120 50/60                       Load

                                                                                                                                     Max. Max.
                                                                                                                                    Amps. kVA

                                                                                                                       0-120 60.0 7.20            67
                                                                                                                       0-140 60.0 8.40

                                                                                                                       0-240 35.0 8.40

                                                                                                                       0-280 35.0 9.80 63

                                                                                                                       0-280 35.0* 4.20*

                                                                                                         Staco Energy Products Co.
Enclosed Cord and Plug Series

The cased plug-in models feature a ventilated steel case, input line cord and                      Plug and Receptacle Styles
plug, NEMA rated output receptacle, and an illuminated on/off switch. They are       3PN 120 Volt Types 3PN 240 Volt Types
connected for output voltage increase with a clockwise rotation, and the dials are
graduated from 0 - 100 percent of the voltage setting. For application flexibility,
two field modification kits have been added to the product line. The 3PN-MK
kit allows either the 3PN221B or 3PN501B to be wall, bench top, or machine
mounted. The 3PN-SK kit provides an adjustable voltage stop for either the
3PN1000, 3PN1200, or 3PN1500 Series.

                                                  Input                                      Output   Constant                                  Net
                                           Volts Hertz                                                                                          Wt.
                               Part No.                      Volts                     Constant       Impedance       Height   Width  Depth     Lbs.
                                                                                        Current
                             3PN221B                                                                        Load
                             3PN501B                                                      Load
                                                                                                      Max. Max.
                                                                                     Max. Max.        Amps. kVA
                                                                                     Amps. kVA

                                           120   60          0-132                   2.50 0.33 --                 -- 5.31 6.06 4.10 3
                                                50/60        0-140                   5.0* 0.70 --                 -- [134.9] [154.0] [104.2] 7.75

                               3PN-MK-Kit

                                                  Input                                      Output   Constant                                  Net
                                           Volts Hertz                                                                                          Wt.
                              Part No.                       Volts                     Constant       Impedance       Height   Width  Depth     Lbs.
                                                                                        Current
                             3PN1010B                                                                       Load
                             3PN1210B                                                     Load
                             3PN1020B                                                                 Max. Max.
                             3PN1220B                                                Max. Max.        Amps. kVA
                                                                                     Amps. kVA

                                           120 50/60         0-140                   10.0 1.40 --                 --   5.50     4.62 6.96       10.25
                                                             0-120                                                    [139.7]  [117.4] [176.8]
                                                             0-280
                                           120  60           0-240                   1 2.0  1.44 15.0       1.80       5.50     4.62 6.96       10.25
                                                                                                                      [139.7]  [117.4] [176.8]

                                           240 50/60                                 3.5 0.98 --                  --   5.50     4.62 6.96       10.25
                                                                                                                      [139.7]  [117.4] [176.8]

                                           240  60                                   5 .0   1.20 7.0        1.68       5.50     4.62 6.96       10.25
                                                                                                                      [139.7]  [117.4] [176.8]

                 3PN-SK-Kit                       Input                                      Output   Constant                                  Net
                                           Volts Hertz                                                                                          Wt.
2200 and 2500 Series          Part No.                       Volts                     Constant       Impedance       Height   Width  Depth     Lbs.
                                           120 50/60                                    Current
                             3PN1510B      240 50/60                                                        Load
                             3PN1520B                                                     Load
                                                                                                      Max. Max.
                                                                                     Max. Max.        Amps. kVA
                                                                                     Amps. kVA

                                                             0-140 15.0 2.10 --                                   --   6.00 6.24 9.35           18
                                                             0-280 9.5 2.66 --                                        [152.4] [158.4] [237.4]

                                                                                                                  --   6.00 6.24 9.35           22
                                                                                                                      [152.4] [158.4] [237.4]

                                                     Input   Volts                            Output      Constant    HxWxD           Net Wt.
                                                             0-140                                    Impedance Load      (cm)          Lbs.
                              Part No.                       0-280                      Constant
                                                Volts Hertz                          Current Load      Max. Max.
                                                                                                      Amps kVA
                             3PN2210B 120 50/60                                      Max. Max.
                             3PN2520B 240 50/60                                      Amps kVA         ----  ---- 6.31x 7.95x 10.85 24.25

                                                                                      22.0 3.08       ----  ---- (160.3x202.1x275.6)

                                                                                      10.0 2.80

Variable Transformers                                                                       www.stacoenergy.com
Metered Models

Cased plug-in models of the 1010B, 1020B, 1510 and 1520 series are       necessary. The 120 volt types have 0-150V voltmeters and the
also available with a pivot and jewel AC voltmeter or ammeter (+/- 5%    240 volt types have 0-300V voltmeters. Units with voltmeters
full scale accuracy) conveniently located atop the enclosure for easy    have the suffix"V" at the end of their part number. Units with
accurate readout. It is ideal for applications where voltage control is  ammeters have the suffix "A."

                                             Part No.        Input                         Output    HxWxD                Net Wt.
                                           3PN1010BV   Volts Hertz                    Volts Current      (cm)               Lbs.
                                           3PN1010BA
                                           3PN1510BV    120 50/60                     0 - 140 10.0   5.50x 4.62x 6.96     10.25
                                           3PN1510BA    120 50/60                     0 - 140 10.0   (139.7x117.4x176.8)  10.25
                                           3PN1020BV    120 50/60                     0 - 140 15.0
                                           3PN1020BA    120 50/60                     0 - 140 15.0   5.50x 4.62x 6.96       18
                                           3PN1520BV    240 50/60                     0 - 280 3.5    (139.7x117.4x176.8)    22
                                           3PN1520BA    240 50/60                                                         10.25
                                                        240 50/60                                    6.00x 6.24x 9.35     10.25
                                                        240 50/60                                    (152.4x158.4x237.4)    22
                                                                                                                            22
                                                                                                     6.00x 6.24x 9.35
                                                                                                     (152.4x158.4x237.4)

                                                                                                     5.50x 4.62x 6.96
                                                                                                     (139.7x117.4x176.8)

                                                                                      0 - 280 3.5    5.50x 4.62x 6.96
                                                                                      0 - 280 95.    (139.7x117.4x176.8)
                                                                                      0 - 280 95.
                                                                                                     6.00x 6.24x 9.35
                                                                                                     (152.4x158.4x237.4)

                                                                                                     6.00x 6.24x 9.35
                                                                                                     (152.4x158.4x237.4)

Isolated Portable Cord and Plug Models

                                            Part No.                          Input         Output   HxWxD                Net Wt.
                                           3PNJ201B                      Volts Hertz  Volts Current      (cm)                Lbs.
                                           3PNJ401B                      120 50/60    0 - 140 2.0
                                                                         120 50/60    0 - 140 4.0    5.50 x 4.62x 6.96    9

                                                                                                     (139.7x117.4x176.8)

                                                                                                     6.00 x 6.24x 9.35    17

                                                                                                     (152.4x158.4x237.4)

Data is subject to change without notice.

                                                                                      Staco Energy Products Co.
Controller Units                                                    The MP Controller comes in three basic models:
                                                                    MPA - Single channel feedback and control
Microprocessor Controller                                           MPB - Two independent channels of feedback and control
                                                                    MPC - Three independent channels of feedback and control
Advantages:
N Intelligent Microprocessor Based                                  Available Options:
N Controls variable voltage transformer regulation to               N Bi-directional RS-232, RS-422, IEEE-488 communication ports
                                                                    N Single, double, or tiiple channel feedback
   within +/-0.5 volts                                              N Process control set point
N Multi-channeled unit enables control of 1, 2 or 3 individual      N Optical isolation of control and feedback inputs for reduced noise

   varaiable transformers or each phase of a 3 phase unit              interference
N LCD display of feedback signals and set points                    N Panel mounted microterminal for local control and monitoring
N Available with standard analog control signals for set            N Phase loss detection

   point and control functions.                                     Typical Applications:
N Available with standard bi-directional RS-232, RS-422,            N Motor and compressor testing
                                                                    N Circuit breaker testing
   IEEE-488 communication ports for set point and control           N Plating rectifier systems
   functions.                                                       N Quality control testing
N Multiple set points, ramping, and dwells are available.           N Engineering laboratories
N User programmable to accept peak-to-peak, rms, or                 N Industrial processes
   average AC feedback signals                                      N Voltage Regulation
N Heavy duty, wall-mountable NEMA 12 style enclosure.
N Control of the unit can be local, at a remote location, or both.                                                           Microprocessor Controller
N Battery back-up RAM retains data if power is lost.                                                                      with optional microterminal
N Microterminal available for remote or stand-alone
   monitoring and control                                           The FRC-20 Controller is a versatile, field modifyable controller
N Precise control of voltage ramping through the use of             that has a low install cost and low cost of operation. It is designed
   state-of-the-art PWM technology                                  to position and regulate any Staco Energy motor driven variable
N Expanded memory allows customiztion to specific                   transformer, and can be controlled with a 0-5 VDC or 4-20 Ma
   application requirements.                                        set point, a 1k ohm potentiometer, or a fixed resistor network.
N Field upgradeable -- options can be installed in the field        It maintains a full range regulation of 0.5% and a limited range
   as your needs change.                                            regulation of 0.25%.
N Automatic shut-down or alarm with phase loss detection            The FRC-20 is field configurable for feedback voltage ranges up
                                                                    to 600 volts, for either full range or limited range control. It is
FRC-20 Controller                                                   small and can be easily mounted on the motor base plate of the
                                                                    variable transformer or inside an enclosure. Current and other
Advantages:                                                         feedback alternatives are also available.
N Regulated Output Voltage
N 0-5 VDC or 4-20 mA Set Point Control
N 1 kohm Potentiometer or Fixed Resistor Network Control
N Full or Limited Range Control
N Compact Size
N Easy to Mount
N Up to 600 VAC Feedback

   Voltage Operation
N Current Regulation

FRC-20 Controller

Variable Transformers                                               www.stacoenergy.com
   Ganged Variable Transformer Assemblies                                     Single Phase Models

High Current Models                                                           Part No.   Input     Output     Current      kVA
By ganging the variable transformers with a common rotor shaft,                                               (Amps)
and wiring the outputs in parallel, the output current can be greatly         6011-2P              0-120                   16.8
increased. The models listed on this page are capable of output               6011-3P                           120.0      25.2
currents up to 540 amps. Other models are available in a variety              6011-4P    120       or           180.0      33.6
of ranges. Please refer to our Variable Transformer Voltage Control           6011-5P                           240.0      42.0
Catalog (VT-5) for additional information.                                    6011-6P              0-140        300.0      50.4
Three Phase Models                                                            6011-7P                           360.0      58.8
All models of Staco variable                                                  6011-8P              0-240        420.0      67.2
transformers can be ganged                                                    6011-9P                           480.0      75.6
with a common rotor shaft                                                     6020-2P    240       or           540.0      19.6
and wired for three phase                                                     6020-3P                                      29.4
operation in either open Delta                                                6020-4P              0-280          70.0     39.2
or Wye configuration. The                                                     6020-5P                           105.0      49.0
table below lists a few typical                                               6020-6P                           140.0      58.8
240 and 480 volt models.                                                      6020-7P                           175.0      68.6
Please refer to our Variable                                                  6020-8P                           210.0      78.4
Transformer Voltage Control                                                   6020-9P                           245.0      88.2
Catalog (VT-5) for additional                                                                                   280.0
models.                                                                                                         315.0

       30M5011-3Y Model                                                       Three Phase Models

                                   Data is subject to change without notice.  Part No.   Input     Output     Current      kVA
                                                                                                              (Amps)

                                                                              221B-3               0-208/120     2.5          1.0
                                                                              291-3                   or         3.0          1.25
                                                                              501C-3                            5 .0          2.1
                                                                              1010B-3              0-240       10.0           4.2
                                                                              1510-3                  with     15.0           6.2
                                                                              2510-3                           25.0         10.4
                                                                              6011-3Y              208/120     60.0         24.9
                                                                              6011-6Y                 input   120.0         49.8
                                                                              6011-9Y                         180.0         74.7
                                                                              M6011-12Y  208/120   0-240      240.0         99.6
                                                                              M6011-15Y     or       or       300.0        124.5
                                                                              M6011-18Y    240                360.0        149.4
                                                                              M6011-21Y            0-280      420.0        174.3
                                                                              M6011-24Y             with      480.0        199.2
                                                                              M6011-27Y             240       540.0        224.1
                                                                              M6011-30Y            input      600.0        249.0
                                                                              M6011-33Y                       660.0        273.9
                                                                              M6011-36Y  480/277   0-480/277  720.0        298.8
                                                                              1020B-3        or         or      3.5           3.4
                                                                              1520-3                            9.5           9.2
                                                                              2520-3       480       0-560     10.0           9.7
                                                                              6020-3Y*                 with    35.0         33.9
                                                                              6020-6Y               480/277    70.0         67.8
                                                                              6020-9Y                 input   105.0        101.7
                                                                              M6020-12Y                       140.0        135.6
                                                                              M6020-15Y                       175.0        169.5
                                                                              M6020-18Y                       210.0        203.5
                                                                              M6020-21Y                       245.0        237.4
                                                                              M6020-24Y                       280.0        271.3
                                                                              M6020-27Y                       315.0        305.1
                                                                              M6020-30Y                       350.0        339.1
                                                                              M6020-33Y                       385.0        373.0
                                                                              M6020-36Y                       420.0        406.9

                                                                              * All 6020 Three Phase Models are rated for 575 volts 60 Hz input, 0-575 volts output.

                                                                                                Staco Energy Products Co.
Service Options

With our ServiStar program, a wide range of planned maintenance and extended
service options are offered to maximize equipment life and reliability of your FirstLine
UPS. Through an extensive network of factory trained professionals you receive:
N Annual Service Plan
N 24/7 Emergency Service
N Preventive Maintenance
N Programs tailored to meet your needs

About Staco Energy Products                           In addition to Variable Transformers
                                                      we offer a wide array of power quality
Since 1937, customers worldwide have been             products, including:
relying on Staco Energy Products Company
to deliver voltage control and power quality          N Uninterruptible Power
solutions tailored to their needs.                      Supplies

As a leading power quality resource, we offer         N Power Conditioners
our customers world-class support; from our
thorough applications assessment, to our              N Voltage Regulators
ability to design and deliver a solution that is
tailored to the specific needs of our customers;      N Power Factor Correction and
through delivery and commissioning.                     Harmonic Mitigation

Our professional, factory trained service team is     N Active Harmonic Filters
in place to ensure that our customers' revenues
are protected, and their investment                   N Variable Transformers
provides them with many years of
trouble free operation.                               N Custom Engineered Test Sets

Staco develops total power solutions
for OEM and end user applications.

                                                      Contact Us:                             ISO
                                                      US Toll Free: 866-261-1191
                                                      Phone: 937-253-1191                     9001 : 2008
                                                      E-mail: sales@stacoenergy.com
                                                                                              CERTIFIED

Your Tailored Power Solutions ProviderTM                                             For more information about Variable Transformers
                                                                                                     www.stacoenergy.com
2014Staco Energy Products Co.  VT-Prod-guide_042514
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Staco:

  3PN1520B 1010B-2 1220BCT 1020BCT 5021 5011 1020B L501B L1010B 1010B-3 6020-3Y 3PN-SK
3PN1510B 201 291 3PN-MK 252 FRC-20 3PN221B 1210BCT 2510CT-3 6020 2510-3 3PN1010B 1510 1520

  3PN1020B 1010BCT 1520CT-3 2520CT-2 1220B 2520 2510 201-3 3PN501B 1010B 2510C 252-3 5011CT
1020B-3 2520-2 2520-3 2510CT 171 6011 501C L221B 3PN1220B 1520-3 1510CT 1220B-2 3PN1210B
2520C 3PN2210B 1210B 1010BCT-3 221-B 3PN1010BV L1010BVA 3PN1010BA 6020CT 5021CT 5M1220BCT-
2 3PN1510BV 1510-2 1510-3 5021-3Y 511 3PN2520B 1520CT 171-2 171-3 201-2 221-B-2 221-B-3 252-2
291-2 291-3 501C-2 501C-3 1010BCT-2 1020B-2 1020BCT-2 1020BCT-3 1210B-3 1210BCT-2 1210BCT-3
1220B-3 1220BCT-2 1220BCT-3 1510C 1510C-2 1510C-3 1510CT-2 1510CT-3 1520-2 1520C 1520C-2
1520C-3 1520CT-2
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company

小广播

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved