289器件文档内容

New Fluke 289
    True-rms Industrial Logging
Multimeter with TrendCapture

                                                                                Technical Data

New diagnostic functionality for maximizing
productivity in the plant.

The new 289 is the next generation high performance industrial logging
multimeter designed to solve complex problems in electronics, plant
automation, power distribution, and electro-mechanical equipment.
With the ability to log data and review it graphically on-screen, you can
solve problems faster and help minimize downtime. Let the new 289
be your watchdog for systems
or processes while you are off
solving other problems.

Equipped with new                       TrendCapture displays vAC logged data.                                                                                                                                                                                                             N10140
functionality
                                    New button. On board                                                                                                                                                                                                                             R
New Large 50,000 count,
                                      help screens for measure-                  Optically isolated communica-
   1/4 VGA dot matrix display         ment functions. Unsure about
   with white backlight               a function--go to that function              tion port for transferring data
                                      and press the "i" button.                    to pc (usb cable and software
New Logging function with                                                      optional)
                                    Real time clock for automatic
   expanded memory for unat-                                                    Limited lifetime warranty
   tended monitoring of signals       time stamping of saved
   over time. Using on-board          readings
   TrendCapture users can graph-
   ically review logged readings    Relative mode to remove test
   without needing a PC. Store
   up to 10,000 readings over         lead resistance from low ohms
   time.                              or capacitance measurements

New Save multiple logging       True-rms ac voltage and

   sessions before pc download        current for accurate measure-
   is necessary                       ments on non linear signals

New Two terminal 50 ohm         Measure up to 10 A (20 A for

   range with 1 milliohm resolu-      30 seconds)
   tion, 10 mA source current.
   Useful for measuring and         100 mF capacitance range
   comparing differences in motor   Peak capture to record tran-
   winding resistance or contact
   resistance.                        sients as fast as 250 s

New Low Pass filter for         Withstands hazardous 8,000

   accurate voltage and frequency     volt spikes caused by load
   measurements on adjustable         switching and faults on indus-
   speed motor drives and other       trial circuits and complies with
   electrically noisy equipment       second edition IEC and ANSI
                                      electrical safety standards.
New LoZ Volts. Low imped-
                                    Optional magnetic hanger
   ance voltage function for
   eliminating ghost voltages.        for easy setup and viewing
   Also recommended when test-        while freeing your hands for
   ing for absence or presence of     other tasks
   live power.
Specifications

Function           Range and Resolution                                           Basic Accuracy
DC volts                                                                               0.025 %
AC volts           50.000 mV,500.00 mV, 5.0000 V, 50.000 V,
DC current         500.00 V, 1000.0 V                                             0.4 % (true-rms)
AC current                                                                              0.15 %
Temperature        500.00 A, 5000.0 A, 50.000 mA, 400.00 mA,
(excluding probe)  5.0000 A, 10.000 A                                             0.7 % (true-rms)
Resistance                                                                              1.0 %
                   -200.0 C to 1350.0 C (-328.0 F to 2462.0 F)
Capacitance                                                                             0.05 %
                   50.000 , 500.00 , 5.0000 k, 50.000 k,
Frequency          500.00 k, 5.0000 M, 50.00 M, 500.0 M                                 1.0 %
                   1.000 nF,10.00 nF 100.0 nF, 1.000 F, 10.00 F,
                   100.0 F, 1000 F, 10.00 mF, 100.0 mF                                .005 %

                   99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz,                       Ordering
                   999.99 kHz                                                          information

Additional Functions/Features            Fluke 289                                       289 True-rms Industrial
Multiple on screen displays                   Yes                                                     Logging Multimeter
True-rms ac bandwidth                                                                                 with TrendCapture
dBV/dBm                                   100 kHz
DC mV resolution                              Yes                                       Optional accessories
Megohm range                                 1 V                                        FVF-SC2 FlukeView Forms
Conductance
Continuity beeper                     up to 500 M                                                     Software with Cable
Battery/fuse access                       50.00 nS                                       TLK289 Industrial Test Lead Set
Elapse time clock                             Yes                                        i400 AC Current Clamp
Time of day clock                                                                        i410 AC/DC Current Clamp
Min-max-avg                             Battery/fuse                                     80BK Integrated DMM
Duty cycle                                    Yes
Pulse width                                   Yes                                                     Temperature Probe
Isolated optical interface                    Yes                                        TPAK Magnetic Hanging Kit
Auto/touch hold                               Yes                                        C280 Soft Case
Reading memory                                Yes
Log to PC                                     Yes                                     Fluke. Keeping your world
Interval/event logging                        Yes                                                up and running.
Logging memory                                Yes
                                              Yes                                      Fluke Corporation
                                              Yes                                      PO Box 9090, Everett, WA USA 98206
                                                                                       Fluke Europe B.V.
                                  up to 10,000 readings                                PO Box 1186, 5602 BD
                                                                                       Eindhoven, The Netherlands
General                           Relative humidity: 0 to 90 %                         For more information call:
specifications                    (0 t 37 C), 0 to 65 % (37 C to                     In the U.S.A. (800) 443-5853 or
                                  45 C), 0 to 45 % (45 C to 55 C)                   Fax (425) 446-5116
Maximum voltage between any       Electromagnetic compatibility:                       In Europe/M-East/Africa +31 (0) 40 2675 200 or
terminal and earth ground:        EMC EN61326-1                                        Fax +31 (0) 40 2675 222
1000 V                            Vibration: Random vibration per                      In Canada (800)-36-FLUKE or
Battery type: 6 AA alkaline       MIL-PRF-28800F Class 2                               Fax (905) 890-6866
batteries, NEDA 15A IEC LR6       Shock: 1 meter drop per IEC/EN                       From other countries +1 (425) 446-5500 or
Battery life: 100 hours minimum,  61010-1 2nd Edition                                  Fax +1 (425) 446-5116
200 hours in logging mode         Size (HxWxL): 22.2 cm x 10.2                         Web access: http://www.fluke.com
Temperature:                      cm x 6 cm (8.75 in x 4.03 in x                        2007 Fluke Corporation. All rights reserved.
Operating: -20 C to 55 C        2.38 in)                                              Specifications subject to change without notice.
Storage: -40 C to 60 C          Weight: 870.9 g (28 oz)                               Printed in U.S.A. 5/2007 11286-ENG Rev. 01

2 Fluke Corporation 289 True-rms Industrial Logging Multimeter with TrendCapture

小广播

289器件购买:

数量 单价(人民币) mouser购买
1 ¥4.65 购买
100 ¥3.69 购买
500 ¥2.46 购买
1000 ¥1.71 购买
2000 ¥1.50 购买