                                                                 Bulletin I2715 rev. I 03/03

SINGLE PHASE BRIDGE                                              MB SERIES

  Features                                                               Power Modules

   Universal, 3 way terminals:                                            25 A
   push-on, wrap around or solder                                         35 A
   High thermal conductivity package,
   electrically insulated case                                                                     1
   Center hole fixing
   Excellent power/volume ratio
   UL E 62320 approved
   Nickel plated terminals solderable as per MIL-STD-202 Method
   208; solder: Sn/Pb (60/40); solder temperature: 235-260C
   max. time: 8-10 secs

Description

A range of extremely compact, encapsulated
single phase bridge rectifiers offering efficient and
reliable operation. They are intended for use in
general purpose and instrumentation applica-
tions.

Major Ratings and Characteristics

Parameters 26MB-A 36MB-A Units

IO           25  35       A

    @ TC     65  60       oC

IFSM @ 50Hz 400  475      A

    @ 60Hz 420   500      A

I2t @ 50Hz 790   1130     A2s

    @ 60Hz 725   1030     A2s

VRRM range   200 to 1200  V

TJ           - 55 to 150  oC

www.irf.com
MB Series

Bulletin I2715 rev. I 03/03

ELECTRICAL SPECIFICATIONS
Voltage Ratings

                      Voltage    VRRM , maximum repetitive      VRSM , maximum non-        I RRM max.
Type number Code                    peak reverse voltage     repetitive peak rev. voltage  @ TJ max.
                                                 V
                                                                              V                  2
         20                                   200
                                              400                             275
         40                                   600                             500
                                              800                             725
26MB..A  60                                   1000                            900
                                              1200                            1100
36MB..A  80                                                                   1300

         100

         120

Forward Conduction

         Parameters                           26MB-A   36MB-A Units Conditions

IO       Maximum DC output current                25    35      A Resistive or inductive load
                                                  20    28
             @ Case temperature                   65    60      A Capacitive load
                                                  400  475     C
IFSM Maximum peak, one-cycle                      420  500
            non-repetitive forward current        335  400      A t = 10ms No voltage
                                                  350  420             t = 8.3ms reapplied
I2t      Maximum I2t for fusing                   790  1130
                                                  725  1030            t = 10ms 100% VRRM
I2t      Maximum I2t for fusing                   560  800             t = 8.3ms reapplied Initial TJ = TJ max.
                                                  512  730    A2s t = 10ms No voltage
VF(TO)1  Low-level of threshold voltage           5.6  11.3
VF(TO)2  High-level of threshold voltage                               t = 8.3ms reapplied
rt1      Low-level forward slope resistance      0.76  0.79
rt2      High-level forward slope resistance     0.92  0.96            t = 10ms 100% VRRM
VFM      Maximum forward voltage drop             6.8   5.8            t = 8.3ms reapplied
                                                  5.0   4.5
IRRM     Max. DC reverse current                 1.11  1.14  KA2s I2t for time tx = I2t x tx ;
VINS     RMS isolation voltage base plate                              0.1  tx  10ms, VRRM = 0V
                                                  10    10
                                                 2700  2700     V (16.7% x  x IF(AV) < I <  x IF(AV)), @ TJmax.
                                                                       (I >  x IF(AV)), @ TJ max.

                                                              m  (16.7% x  x IF(AV) < I <  x IF(AV)), @ TJmax.
                                                                       (I >  x IF(AV)), @ TJ max.

                                                                V TJ = 25 oC, IFM = 40APK (26MB) tp = 400s
                                                                       TJ = 25 oC, IFM = 55APK (36MB)

                                                               A TJ = 25 oC, per diode at VRRM
                                                                V f = 50 Hz, t = 1s

2                                                                                          www.irf.com
                                                                                                              MB Series

                                                                                                 Bulletin I2715 rev. I 03/03

Thermal and Mechanical Specifications

Parameters                                            26MB-A 36MB-A Units Conditions

TJ Junction temperature range                                                 - 55 to 150 oC
Tstg Storage temperature range
RthJC Max. thermal resistance junction to case                                - 55 to 150 oC
RthCS Max. thermal resistance, case to heatsink
wt Approximate weight                                 1.7                             1.2        K/W Per bridge
                                                                                                 K/W Mounting surface , smooth, flat and greased
T Mounting Torque 10%                                                       0.2
                                                                                                   g
                                                                              20                 Nm Bridge to heatsink

                                                                              2.0

Ordering Information Table

                           Device Code

                                            36 MB 120 A

                                                   1                       2       3          4

                                        1-         Current rating code:                          26 = 25A (Avg)
                                        2-                                                       36 = 35A (Avg)
                                                   Circuit configuration:
                                        3-         MB = Single phase european coding
                                        4-
                                                   Voltage code: MB series = code x 10 = VRRM

                                                   Diode bridge rectifier:
                                                   A = 26MB, 36MB Series

Outline Table                           6.3 (.25)

                             0.8 (.03)

                                                   10.5 (.41)                              Suggested plugging force:
                                                               20.3 (.80)                  200 N max; axially applied to faston terminals

        Not To Scale                                                                  All dimensions in millimetres (inches)

www.irf.com                                                                                                                                   3
MB SeriesMaximum Allowable Case temperature (C)                                                                                    Instantaneous Forward Current (A)        1000  Tj = 25C
                                                                                                                                                                              100
Bulletin I2715 rev. I 03/03                                                                                                                                                                             Tj = 150C

      150
                                    26MB..A Series

      130

                                         110
                                                                                 180

                                                                                (Rect)
                                          90

                                         70                                                    180                                                                          10

                                                                                           (Sine)                                                                                                           26MB..A Series
                                                                                                                                                                              1
                                         50                                                                                                                                    0.5 1 1.5 2 2.5 3 3.5
                                            0 5 10 15 20 25 30
                                                    Average Forward Current (A)                                                                                                     Instantaneous Forward Voltage (V)
                                                                                                                                                                             Fig. 2 - Forward Voltage Drop Characteristics
                                             Fig. 1 - Current Ratings Characteristics
                                                                                                                                                                                   Maximum Allowable Ambient Te

                                         Maximum Average Forward Power Loss (W)  50                                   180                       - Delta R
                                                                                                                     (Sine)         RthSA = 1 K/W
                                                                                       26MB..A Series
                                                                                                                               2 K/W
                                                                                       Tj = 150C                            3 K/W
                                                                                 40                                          4 K/W
                                                                                                                             5 K/W
                                                                                 30                                  180    7 K/W

                                                                                                                     (Rect)  10 K/W

                                                                                 20

                                                                                 10

                                                                                 0

                                                                                     0  5      10 15 20 205 25 50 75 100 125 150

                                                                                        Average Forward Current (A) Maximum Allowable Ambient Temperature (C)

                                                                                                       Fig. 3 - Total Power Loss Characteristics

Peak Half Sine Wave Forward Current (A)  400                                                                                        Peak Half Sine Wave Forward Current (A)  450

                                                   At Any Rated Load Condition And With                                                                                              Maximum Non Repetitive Surge Current

                                                                                 Rated Vrrm Applied Following Surge                                                                Versus Pulse Train Duration.

                                         350                                               Initial Tj = 150C                                                                                           Initial Tj = 150C

                                                                                           @ 60 Hz 0.0083 s                                                                  350                   No Voltage Reapplied

                                                                              @ 50 Hz 0.0100 s                                                                                                     Rated Vrrm Reapplied

                                         300

                                         250                                                                                                                                 250

                                         200

                                                                                                                                                                             150

                                         150                                                                                                                                       26MB..A Series
                                                 26MB..A series

                                         100                                                                                                                                 50
                                              1
                                                                                           10                        100                                                     0.01                  0.1                      1

                                              Number of Equal Amplitude Half Cycle Current Pulses (N)                                                                              Pulse Train Duration (s)

                                         Fig. 4 - Maximum Non-Repetitive Surge Current                                                                                       Fig. 5 - Maximum Non-Repetitive Surge Current

4                                                                                                                                                                                                       www.irf.com
                                                                                                                                                                                                              MB Series

                                                                                                                                                                                                 Bulletin I2715 rev. I 03/03

Maximum Allowable Case temperature (C)  150                                                                                          Instantaneous Forward Current (A)        1000              Tj = 25C
                                                                          36MB..A Series                                                                                        100
                                                                                                                                                                                                                 Tj = 150C
                                         130

                                         110
                                                                                  180
                                                                                 (Rect)

                                          90

                                                                                             180                                                                              10
                                                                                                                                                                                                            36MB..A Series
                                         70                                                  (Sine)

                                         50                                                                                                                                          1
                                            0 5 10 15 20 25 30 35 40                                                                                                                  0.5 1 1.5 2 2.5 3 3.5
                                                    Average Forward Current (A)
                                                                                                                                                                                           Instantaneous Forward Voltage (V)
                                             Fig. 6 - Current Ratings Characteristics
                                                                                                                                                                                    Fig. 7 - Forward Voltage Drop Characteristics
                                                 Maximum Average Forward Power Loss (W)
                                                                                                                                                                                         Maximum Allowable Ambient Te

                                                                                         80                     180               RthSA  =  0.7
                                                                                               36MB..A Series  (Sine)          1 K/W
                                                                                               Tj = 150C                       2 K/W                                          K/W  -
                                                                                                                         180
                                                                                         60                            (Rect)                                                          Delta  R

                                                                                         40                                    3 K/W

                                                                                         20                                    4 K/W
                                                                                                                               5 K/W

                                                                                                                               7 K/W

                                                                                         0
                                                                                           0 5 10 15 20 25 30 305 25 50 75 100 125 150
                                                                                                   Average Forward Current (A) Maximum Allowable Ambient Temperature (C)

                                                                                                                   Fig. 3 - Total Power Loss Characteristics

Peak Half Sine Wave Forward Current (A)  450                                                                                          Peak Half Sine Wave Forward Current (A)  500

                                                  At Any Rated Load Condition And With                                                                                                 Maximum Non Repetitive Surge Current

                                         400     Rated Vrrm Applied Following Surge.                                                                                           450               Versus Pulse Train Duration.
                                                                             Initial Tj = 150C
                                                                                                                                                                                                                 Initial Tj = 150C

                                                                                                 @ 60 Hz 0.0083 s                                                              400                          No Voltage Reapplied
                                                                                                                                                                                                            Rated Vrrm Reapplied
                                         350                                                     @ 50 Hz 0.0100 s

                                                                                                                                                                               350

                                         300

                                                                                                                                                                               300

                                         250                                                                                                                                   250

                                         200                                                                                                                                   200
                                                                                                                                                                               150 36MB..A Series
                                         150 36MB..A Series

                                         100                                                                                                                                   100
                                              1
                                                                                             10                    100                                                                 0.01                 0.1                      1

                                              Number of Equal Amplitude Half Cycle Current Pulses (N)                                                                                            Pulse Train Duration (s)

                                         Fig. 9 - Maximum Non-Repetitive Surge Current                                                                                         Fig. 10 - Maximum Non-Repetitive Surge Current

www.irf.com                                                                                                                                                                                                                     5
MB Series

Bulletin I2715 rev. I 03/03

                                       Data and specifications subject to change without notice.
   This product has been designed and qualified for Industrial and Consumer Level.

                                          Qualification Standards can be found on IR's Web site.

IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
                                                                                                                   TAC Fax: (310) 252-7309

                                                                Visit us at www.irf.com for sales contact information. 03/03

6                            www.irf.com
This datasheet has been downloaded from:
             www.EEworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved