器件描述

2pos blk SH lvr det-22mm metal

参数

Datasheets:
Snap Action Switches Guide:
Limit Switches Guide:
Product Photos:
24678174:
Other Related Documents:
Declaration of Conformity:
Standard Package : 1
Category: Industrial Controls, Meters
Family: Accessories
Series: *
Dynamic Catalog: Industrial Controls, Meters Accessories
Other Names: 24678174-ND966-1105

24678174器件文档内容

Snap Action Switches Technical Guide

These basic principles apply to all           Switch construction
our precision switches. The specific
characteristics of each model are given       Single-pole changeover switch (i.e. 83 161)
in more detail in the relevant production
sections.                                                             Push button
                                                                                   Case
                                                                                           Mounting hole

Introduction                                     Return spring                                                                 Terminal NC n2
                                                  Mounting hole                                                           Contact mobile
Our switches are high-precision, snap-action
switches and these are a few of the key                                                                                        Contact fixed
features which distinguish our switches:                                                                                       Terminal NO n4
- High ratings with small dimensions
- Very short travels                                                                                           Common terminal C n1
- Low operating forces
- Highly dependable force and travel values                                   Pivot point
- Long life                                                           Blade
- Large range of actuators for easy

  adaptation to the most varied applications

                                              Electrical function              Normally closed (NC)                          Normally open (NO)
                                              SPDT (C)

                                                                  2         1              2                              1                       4

                                              1                   4

                                              Double-pole changeover switch (i.e. 83 132 0)

                                                                            Blade        Push button
                                                                                                           Contact fixed
                                                                      Case

                                                 Terminal NO n3                                                                 Terminal NO n4
                                                 Terminal NC n1
                                                                                                                             Contact mobile
                                                                                                                                 Terminal NC n2

                                                                      Mounting hole             Mounting hole
                                                                                         Return spring

                                              Electrical function              Normally closed (NC)                          Normally open (NO)
                                              SPDT (C)

                                              3                    4        1              2                              3                       4

                                              1                    2

                                              The NO and NC circuits must both be of the same polarity.

                                              Products and specifications subject to change without notice.

       Order/Technical Support Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com

3/104
Snap Action Switches Technical Guide

Mechanical characteristics

Terminology - Forces - Positions - Travel

                                                                   OF                                                    TTF                             RF

Position of pushbutton                                         PT                                         OT
                                                                                                                                           DT

                        RP                                         TP                                                    OL                              RLP

Electrical
  circuit

                                                               OF Operating Force                         TTF Total travel force                         RF Release force

                                                               Maximum force which must be applied to     Force required to displace the operating       Force to which the operating force must
                                                               the operating device to displace the rest  device from its rest position RP to its        be reduced to allow the snap-action
                                                               position RP to the tripping point TP.      overtravel limit position. (We only specify    mechanism to return to its release
                                                                                                          this value if it is higher than the operating  position RLP.
                                                                                                          force. When not quoted, it is equal to or
Forces                                                                                                    less than the operating force).

                                                                                                          MOF Maximum overtravel force

                                                                                                          The maximum force which can be

                                                                                                          applied to the operating device, without                                                      3
                                                                                                          damaging it, in the end of travel position
                                                                                                          where it is in abutment internally or

                                                                                                          against the face of the case.

Positions               RP Rest position                       TP Tripping point                          OL Overtravel limit                            RLP Release position
                        Position of the operating device       Position of the operating device relative  Position of the operating device when an       Position of the operating device at the
                        when no external mechanical force is   to the fixing point (hole, face) at the    extreme force has moved it to the              moment when the snap-action mechanism
                        applied. Also described as "height at  moment when the microswitch trips.         effective end of the available travel.         trips on its return to its original position.
                        rest".

Travel                                                         PT Pre-travel                              OT Overtravel                                  DT Differential travel
                                                               Distance between the rest position RP      Distance between the tripping point TP         Distance between the tripping point TP
                                                               and the tripping point TP.                 and the overtravel limit OL.                   and the release position RLP.

The reference point for the figures given for travel and forces is a point F situated on the button in the case of a plain microswitch, or, generally, 3 mm in from the end of a plain actuator.
The reference point for the positions is one of the fixing holes, unless otherwise indicated.

Graphs of forces vs. travel                                                                               Contact force

Operating force (external) applied                                 depression                                                                            Force after depression:
to the operating device                                            return

                                                                                                                                                         return  outward

                                                                               Button movement

                                                                                                                Contact
                                                                                                                force

                                                               Products and specifications subject to change without notice.

                        Order/Technical Support Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com

                                                                                                                                                                 3/105
Snap Action Switches Technical Guide

Mechanical characteristics                                          Environmental conditions

       Changeover time                                              Resistance to shocks and vibrations

       This is the time taken by the mobile contact                 Resistance to impact and vibration depends on
       when moving from one fixed contact to another                the mass of the moving parts and on the forces
       until it becomes fully stable (contact bounce                holding the contacts together.
       included). This time is a function of the contact            Generally speaking, for a switch without an
       gap, the mechanical characteristics of the snap              actuator :
       action and the mass of the mobile element.                   - Vibration >10 G 10 at 500 Hz
       However, thanks to the snap-action                           - Impact > 50 G 11 ms 1/2 sine-wave
       mechanisms employed, the time is largely                     Further information on request.
       independent of the speed of operation.
       It is normally less that 20 milliseconds                     Ambient operating temperature
       (including bounce times of less than 5 ms).                  The maximum and minimum temperatures at
                                                                    which the mechanical and electrical
                                                   Bounce time      characteristics of the switch will remain
                                                   Changeover time  substantially unaltered.

                                     about

       Mechanical durability                                        Degree of protection

       This is an average value indicating the                      Under the IEC 529 or NFC 20010 classification
       purely mechanical performance of a switch                    scheme, standards employ an IP code to
       when not subject to any electrical load.                     define the degree or class of protection which
       It may be useful for evaluation purposes in                  electrical equipment provides against access
       cases where the power levels involved are                    to live components, the entry of solid foreign
       very low and the electrical life is thus close               bodies and ingress of water.
       to the mechanical life.

       Maximum speed and rate of operation                          1st numeral                 Protection for persons
                                                                                                against access to
       Our switches will work at speeds of operation                Protection equipment        dangerous parts
       varying over a very wide range : normally                    provides against the entry
       from 1 mm/min to 1 ms.                                       of solid foreign bodies
       The maximum rate of operation with a low
       electrical load may be as high as 10                         0 (not protected)           (not protected)
       operations/second.                                           4 diameter  1 mm            1 mm wire
                                                                    5 protected against dust    1 mm wire
                                                                    6 sealed against dust       1 mm wire

       Mounting - Operation                                          2nd numeral
                                                                     Protection equipment
       To conform to the leakage paths and air gaps                provides against ingress of
        in the standard EEC24 - EN/IEC 61058 -                       water
        EN/IEC 60947:
                                                                     0 (not protected)
       - An insulation pad must be inserted between                  4 splashed water
        the switch and the fixing surface if the latter is           5 hosed water
        metal.                                                       6 high-pressure

       - Manual operation of a metal actuator must                       hosed water
        only be carried out with the help of a secondary             7 temporary immersion
        actuator made of insulating materials.                       8 prolonged immersion

       The installer must ensure adequate protection              Under this classification, our switches come
        against direct contact with the output terminals.           within the following categories :
                                                                    - Plain switches = IP 00
       Fixing - Screw torque                                        - Protected switches = IP 40 with isolated

       Unless otherwise indicated in the mechanical                connection
         characteristics table, the torque required                 - Sealed switches = IP 66 or IP 67
         for the fixing screws must conform to the
         following values :

       of fixing screw             2      2.5 3  3.5 4
                                            35 60  100 150
       Screw torque         maximum  25     25 40  60 100
       in cm.N
                            minimum 15

                                              Products and specifications subject to change without notice.

       Order/Technical Support Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com

3/106
Snap Action Switches Technical Guide

Dielectric characteristics                                                            Circuit types

                                Current rating                                                       Resistive circuit
                                   This is the current the switch is capable of
                                   making and breaking which forms the basis for                     For a circuit with alternating voltage, this is in
                                   the life tests.                                                   phase with the current : Cos  = 1.

Thermal rating                                                                        =L             Inductive circuit
                                                                                           R
This is the current the switch will withstand                                             M          A circuit of this type with direct current is
when not being operated, for a temperature                                                           characterised by a time constant.
rise of not more than 60 C.                                                                         An inductive circuit, with alternating voltage, for
                                                                                                     example, incorporating a motor (cos  < 1) can
Switch rating                                                                                        cause current surges up to 6 times the normal
                                                                                                     current. For certain switches, we give electrical
AC voltages: see the current rating.                                                                 endurance curves with L = 5 ms in DC
With DC voltages the switch rating is very much
dependent on the voltage, the contact gap                                                                                           R
(CG) and the nature of the load being switched.                                                      and cos  = 0.8 in AC.
There is a risk of prolonged or indeed
permanent arcing if the following limits are
exceeded:

220         Limit of constant current D.C.                                                           Lamp and capacitance circuit
110                              Resistive load
                                 Inductive load L/R = 5 ms                                           The currents at the time when the circuit is         3
                                                                                                     closed are very high in this case, being up to
                                                                          EC=3 mm                    10 times the nominal figure.
                                                                             CG=3 mm
                                 
                       
48
24          EC=0.4 mm         

            CG=0.4 mm

12

            0.3 0.5 1 2            5 10 16                                                           Internal resistance

For special applications, please enquire.                                                            This consists of the intrinsic resistance (fixed)
                                                                                                     of the parts carrying current and the contact
Operating curves                                                                                     resistance (variable).
                                                                                                     Close to the tripping point and release position,
These indicate the electrical life of the                                                            the force holding the contacts together drops
switches, under standard conditions (20 C,                                                          considerably and this may cause a rise in
1 cycle/2 seconds), by showing the number of                                                         internal resistance.
switching operations which can be performed
with given types of load.                                                                            Insulation resistance

Number      Resistive circuit                                                                        The insulation resistance of the switches is
of          Inductive circuit                                                                        generally greater than 50,000 M measured at
operations                                                                                           500 V DC.

                                                                                                     Dielectric strength

                                                                                                     The dielectric strength of our switches is
                                                                                                     generally better than:
                                                                                                     - 1500 volts between live parts and earth
                                                                                                     - 1000 volts between contacts
                                                                                                     - 600 volts between contacts for switches

                                                                                                       whose contact gap is less than 0.3 mm.

                                   Rating in
                                   Amps

                                       Products and specifications subject to change without notice.

Order/Technical Support Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com

                                                                                                                                   3/107
Snap Action Switches Technical Guide

Contact materials                                                                Electrical recommendations

                                Choice of contact material                                                        Inductive circuits
                                                                                                                    To increase the life of contacts and their DC
                                   To choose the best material for the contacts                                     rating, arcing on opening can be cut down by
                                   there are various factors to be considered:                                      using the following circuits:
                                   - the current and voltages levels
                                   - the type of load                                                                - for DC
                                   - the number of operations                                                        Fast diode V R > 5 x V nominal
                                   - the switching frequency
                                   - the environmental conditions.                                                                   I nominal > 10 x I winding

       Contacts for general-purpose use

       Our switches are normally fitted with silver                              A      - for DC or AC

       contacts. These are suitable for the majority of                                   A - RC circuit across inductor
                                                                                          B - RC circuit across switch
       applications and provide the best compromise
                                                                                            C (nF) ~100 x I nominal (A)
       between electrical performance, thermal                                              V insulation > V peak
                                                                                            R() ~ load resistance ()
       performance and life.                                                     B
                                                                                          C - Varistor circuit across load
                                                                                     C    D - Varistor circuit across switch
       Contacts for low-power circuits                                                    V > V peak supply
                                                                                          E (J)  P(V.A.)
       E < 20 V and/or I < 100 mA
                                                                                                        100
       The contacts used in this case are plated with                            D

       gold (or a gold alloy) for good reliability even in

       corrosive atmospheres.

       Contacts for special applications                                                Very low power circuits
                                                                                        In very low power circuits (I > 1 mA, V  5 V),
       We can supply special contacts suitable for                                      switching is highly sensitive to environmental
       particular applications, such as:                                                conditions (the atmosphere, pollution).
       - Ag CdO contacts for very high drawn
                                                                                        If the supply is powerful enough, adding a
         currents,                                                                      passive resistor to increase the current broken
       - Cross Bar gold-plated Ag Ni contacts which                                     by the switch to a few milliamps will
                                                                                        substantially improve reliability of operation.
         allow a very wide range of applications to be
         covered by a single type of switch.                                            R - Load resistance
                                                                                        C - Very low current load

                                              Products and specifications subject to change without notice.

       Order/Technical Support Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com

3/108
Snap Action Switches Technical Guide

Methods of actuation                                           Standards - Approvals

          Direct operation                                     Our switches are designed according to
          Preferably, force should be directly applied         international recommendations (IEC), American
          to the device the plunger along its axis         standards (UL) and/or European standards
          for operation. However, the majority of our          (EN).
          microswitches will accept skewed operation
          provided the angle of application is not more        Proof of compliance with these standards and
          than 45.                                            recommendations is demonstrated by:

          The device used to apply the force must never        - the manufacturer's declaration of conformity
          hamper the travel of the plunger to the tripping       (drafted in accordance with the ISO/IEC 22
          point (TP). It must under all circumstances            guidelines), or
          move the plunger through at least 0.5 times
          the overtravel (OT) quoted. Steps must also          - approval granted directly by an accredited
          be taken to see that it does not cause the             body, or by application of the CCA (Cenelec
          overtravel limit (OL) or maximum overtravel            Certification Agreement).
          force (MOF) quoted to be overrun or exceeded.
                                                               More detailed information on the approval for a
                                                               particular type of microswitch can be obtained
                                                               on request.

          Operation by actuator

          When operation is by a roller lever, force
          should preferably be applied in the direction
          shown on the left.

       +  Where the movements involved are fast, the                                   3
Quality   ramp should be so designed as to ensure that
          the operating device is not subjected to any         The 83170 switch as an example
          violent impact or abrupt release.                    An 83 170 4 switch marked with the symbols
                                                               for the European (according to CCA/MC12)
          Quality is built into our switches from the initial  and American approvals it holds.
          design stage right through to the point where
          they are put into action at the customer's
          premises. All departments of the company are
          guided by the Quality Manual and the
          stipulations of the ISO 9000 international
          standard.
          The location where the switches are
          manufactured (the la Plaine works at Valence)
          holds ISO 9001 certification, guaranteeing a
          high standard of quality.

          Control procedures                                   Rules and regulations

          Manufacturing quality of our switches is                                             EC directives
          controlled systematically during assembly                                               Our switches are compatible with European
          operations and on final completion. All our                                             Community technical directive (Low Voltage)
          products are subjected to a final inspection,                                           73/23 and can be used within the framework
          either at 100% on important characteristics, or                                         of Machinery directive 83/392.
          according to the statistical sampling rules of
          French standards X 06-222 and X 06-023. The                                          Environmental protection
          quality levels applied, for normal use such as                                          The modern concept of protection of the
          defined in previous paragraphs are for the                                              environment is an integral part of the
          following defects, according to the standards :                                         manufacture of our switches, from product
          - critical fault : NQA : 0.40                                                           design through to packaging.
          - major fault : NQA : 1
          - minor fault : NQA : 2.5

          At the customer's request, and for certain
          ranges of our products which must meet
          specific needs expressed in the specifications,
          it is always possible to adapt or create an
          inspection specification of a standard product.

                                                 Products and specifications subject to change without notice.

          Order/Technical Support Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com

                                                                                                                3/109
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company

小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved