Thermostats COMMERCIAL THERMAL

参数
产品属性属性值
产品种类:
Product Category:
Thermostats
制造商:
Manufacturer:
Honeywell
RoHS:YES
Function:Open on Rise
Temperature Range:0 C to + 150 C
电流额定值:
Current Rating:
15 A, 10 A
电压额定值:
Voltage Rating:
120 VAC, 250 VAC
产品:
Product:
Phenolic Automatic Reset Thermostats
商标:
Brand:
Honeywell
系列:
Series:
2455R
工厂包装数量:
Factory Pack Quantity:
50

2455R-00750850器件文档内容

Commercial

Thermostats

DESCRIPTION                                                    These snap-action thermostats include automatic and manual

Thermostats can provide either temperature control or over-    reset options, phenolic or ceramic housings and a wide variety

temperature protection by breaking electrical contact when a   of mounting brackets and terminal options.

specified temperature is reached.

                                                               Each thermostat's design is configured from a base unit, and

Honeywell manufactures a wide range of 12,7 mm [0.5 in]        may be customized for temperature tolerance and mechanical

commercial snap-action thermostats for possible use in a wide  configurations, meeting the customer’s needs for accuracy and

array of small and major appliances, office copy machines,     exactitude.

medical equipment, heat detectors, HVAC equipment and

more.                                                          Honeywell can also integrate these thermostats in higher value

                                                               cable assemblies, incorporating wire harness and connectors.

TABLE OF CONTENTS

DESCRIPTION                                                                                                p.                1

NOMENCLATURE                                                                                               p.                2

DEFINITION OF TERMS                                                                                        p.                3

NOTES                                                                                                      p.                3

COMMERCIAL THERMOSTATS

2450R/2450HR/2455R/2452R/2452HR Series Phenolic Automatic Reset                                            p.                4

2450RC/2450RCH/2455RC Series Ceramic Automatic Reset                                                       p.                6

2455RM/2450CM Series Phenolic or Ceramic Manual Reset                                                      p.                9

2455RD Series Phenolic Manual Reset                                                                        p.                11

2455RBV Series Overmolded Automatic Reset                                                                  p.                13

2450A/2455RA Series Heat Detection                                                                         p.                15

2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series “One Shot”                                                 p.                17

REDI-TEMP THERMOSTATS

3455RC Series                                                                                              p.                19

MOUNTING HARDWARE

Brackets                                                                                                   p.                20

Brass mounting studs                                                                                       p.                21

Terminals                                                                                                  p.                22
Commercial Thermostats

NOMENCLATURE

The nomenclature given in Figure 1 is provided for reference  only.

Figure 1. Commercial Thermostat Nomenclature

2  www.honeywell.com/sensing
DEFINITION OF TERMS

•  Automatic Reset: A type of thermostat that will automatically reset at a specific temperature (i.e. a thermostat operates at

   65,5 oC [150 oF] and resets at 48,89 oC [120 oF]).

•  Bimetal: Two dissimilar metals bonded together to form the material for manufacturing thermally-sensitive discs which actuate

   the thermostat.

•  Close on Rise (COR): Refers to operation of the contacts. When the temperature rises to its set point, the contacts close or

   make contact and complete the circuit.

•  Contact Resistance: The value of resistance measured between the terminals.

•  Dielectric Strength: The value of insulation between two electrically conducting parts. It may be tested by the application of a

   predetermined overvoltage for a specified time.

•  Differential: The temperature difference between the operate and reset set points, also known as operate and reset.

   -   Nominal: The temperature difference between nominal set points regardless of tolerance.

   -   Maximum: Maximum number of degrees between actual opening and closing set points.

   -   Minimum: Minimum number of degrees between actual opening and closing set points.

•  Exposure Temperature: Thermal environment of a device during application operation.

•  FLA (Full Load Amps): Current taken from the line by the motor when the motor is yielding the rated hp at the rated voltage

   and frequency.

•  Life Cycles: The endurance rating of the thermostat expressed in number of operations with stated electrical load applied.

   Temperature limit application = open on rise.

•  LRA (Locked Rotor Amps): The amount of current the motor can be expected to draw under starting conditions when full

   voltage is applied, also known as starting inrush current.

•  Manual Reset: A bimetal thermostat with a reset button that must be pressed to reset the contacts.

•  Open on Rise (OOR): Refers to the operation of contacts. When the temperature rises to its set point the contacts open,

   terminating the circuit.

•  Overmold: Encapsulation with an insulating material.

•  Phenolic: Thermoset plastic used for the insulating body of the thermostat.

•  Set Point: The nominal temperature at which the thermostat operates.

•  SPST (Single Pole/Single Throw): A switch with one current path which can be either open or closed.

•  Tolerance: The allowable range above and below the set point temperature.

•  Operate: Change of state when the thermostat reaches its set point.

•  Reset: Change of state when the thermostat returns to its original condition prior to operation.

NOTES

•  Standard Temperature Characteristics Tables:

   -   Temperatures: Please consult applications engineering for temperature ranges, tolerances and differentials not noted.

       The operating temperature ranges include tolerances.

   -   Tolerances: The ± tolerances given have been established after review of many thermostat applications. Attempts should

       be made to establish the widest acceptable tolerance possible.

•  UL and CSA Approvals: 12,7 mm [0.5 in] thermostats are available with multiple agency approval for incorporation into

   equipment.

•  Fan control applications: Require thermostat set points to be derated by 20 °C from the equivalent temperature limit

   application. They also close on rise.

•  Dimensions: Are for reference only and are given in mm [in].

                                                                                                     Honeywell Sensing and Control   3
Commercial Thermostats

Figure 2. 2450R/2450HR/2455R/2452R/2452HR Series Phenolic Automatic Reset Thermostat

   The 2450R/2450HR/2455R/2452R/2452HR Series is a                All versions are UL/CSA approved.

   single pole, single throw, snap-acting, non-adjustable         The 2452R/2452HR/2455R version     meets  the  requirements    of

   thermostat which may be used in applications such as           EN60730-01.

   power supplies, general appliances and medical equipment.

   A temperature-sensitive bimetal disc, electrically and         Potential applications include:

   thermally isolated from the switch, is used to actuate the     •  Power supplies

   normally-closed contacts. Contacts open when surface or        •  Appliances

   ambient temperatures increase to the operating set point of    •  Medical equipment

   the calibrated bimetal disc. The entire switch is enclosed in  •  Water heaters

   a phenolic housing; the bimetal disc is retained by a metal    •  Office automation

   heat-conducting end cap. Due to the small size of this unit    •  Industrial equipment

   and the inherently low mass of the bimetal snap-action disc,   •  HVAC equipment

   response of this thermostat to temperature changes is

   extremely rapid, compared to other commercially available

   thermostatic devices. A variety of mounting brackets and

   terminals are available.

Table 1. 2450R/2450HR/2455R/2452R/2452HR Series                Standard Temperature Characteristics

   Operating Temperature Range                                    Tolerance                          Standard Mean Differential

                                Open                                         Close                          °C [°F]

                                °C [°F]                                      °C [°F]

                                ±4 [±7]                                      ±6 [±10]                28 to 34 [50 to 60]

   0 °C to 26 °C                ±4 [±6]                                      ±6 [±10]                22 to 27 [40 to 49]

   [32 °F to 79 °F]             ±4 [±6]                                      ±5 [±9]                 17 to 22 [30 to 39]

                                ±4 [±6]                                      ±5 [±8]                 14 to 16 [25 to 29]

                                ±3 [±5]                                      ±5 [±8]                 8 to 14 [15 to 24]

                                ±5 [±9]                                      ±8 [±15]                45 to 56 [81 to 100]

                                ±4 [±7]                                      ±6 [±11]                34 to 45 [61 to 80]

   27 °C to 82 °C               ±4 [±6]                                      ±6 [±10]                28 to 34 [50 to 60]

   [80 °F to 180 °F]            ±3 [±5]                                      ±6 [±10]                22 to 27 [40 to 49]

                                ±3 [±5]                                      ±5 [±9]                 17 to 22 [30 to 39]

                                ±3 [±5]                                      ±5 [±8]                 8 to 16 [15 to 29]

                                ±6 [±10]                                     ±8 [±15]                45 to 56 [81 to 100]

                                ±5 [±8]                                      ±8 [±15]                34 to 45 [61 to 80]

   83 °C to 110 °C              ±4 [±7]                                      ±7 [±12]                28 to 34 [50 to 60]

   [181 °F to 230 °F]           ±4 [±6]                                      ±6 [±10]                22 to 27 [40 to 49]

                                ±4 [±6]                                      ±5 [±9]                 17 to 22 [30 to 39]

                                ±4 [±6]                                      ±5 [±8]                 8 to 16 [15 to 29]

                                ±7 [±12]                                     ±10 [±18]               45 to 56 [80 to 100]

                                ±5 [±9]                                      ±8 [±15]                34 to 45 [61 to 80]

   111 °C to 150 °C             ±5 [±8]                                      ±7 [±12]                28 to 34 [50 to 60]

   [231 °F to 302 °F]           ±4 [±7]                                      ±7 [±12]                22 to 27 [40 to 49]

                                ±4 [±7]                                      ±6 [±11]                17 to 22 [30 to 39]

                                ±4 [±7]                                      ±6 [±10]                14 to 16 [25 to 29]

4  www.honeywell.com/sensing
Table 2. 2450R/2450HR/2455R/2452R/2452HR Series Specifications

Characteristic                  Parameter

Switch type                     SPST

Reset type                      automatic

Amperage                        See Tables 3, 4

Voltage                         120 Vac to 250 Vac

Operating temperature range     0 °C to 150 °C [32 °F to 302 °F]

Environmental exposure range    -18 °C to 177 °C [0 °F to 350 °F]

Materials:

Base                            phenolic

Contacts                        silver alloy

Terminals                       unplated brass, plated brass or steel

Closure                         aluminum, brass or stainless steel

Brackets                        aluminum or stainless steel

UL and CSA approvals            •  2455R: 6,35 mm [0.25 in] clearance; UL File MH8267, UL File E36103; CSA File  LR21048

                                •  2450HR: 1,59 mm [0.0625 in] clearance; UL File E36103; CSA File LR21048

                                •  2450R: 1,59 mm [0.0625 in] clearance; UL File E36103; CSA File LR 21048

                                •  2452R: 2.66mm [0.105 in] clearance; UL E36103

                                •  2452HR: 2.66mm [0.105 in] clearance; UL36103

Weight                          6 g [0.2 oz] (does not include brackets or wire leads)

Table 3. 2450R/2450HR/2452R/2452HR Contact Ratings

         Life Cycles                      120 Vac                          240 Vac                   277 Vac

            100,000                   15 A resistive                       10 A resistive            10 A resistive

             30,000                125 VA pilot duty                       125 VA pilot duty                -

Note: 2450 approval rating is limited by EN60730-1 to 125 Vac max.

Table 4. 2455R Contact Ratings

         Life Cycles                      120 Vac                          240 Vac                   277 Vac

            100,000                   15 A resistive                       10 A resistive            7.2 A resistive

                                   4.4 FLA 26.4 LRA                        2.2 FLA 13.2 LRA

                                   125 VA pilot duty                       125 VA pilot duty

             6,000                 5.8 FLA, 34.8 LRA                       2.9 FLA, 17.4 LRA                -

Note: Additional contact ratings are available, please contact Honeywell.

Figure 3. 2450R/2450HR/2455R/2452R/2452HR Basic Dimensions

2450R                                 2450HR                                                  2455R

2452R                                 2452HR

                                                                                              Honeywell Sensing and Control  5
Commercial Thermostats

Figure 4. 2450RC/2450RCH/2455RC Series Automatic Reset Thermostat

   The 2450RC/2450RCH/2455RC Series is a single pole,              All versions are UL/CSA and European approved.

   single throw, snap-acting, non-adjustable thermostat which

   may be used in applications such as industrial and electrical   Potential applications include high temperature control for:

   equipment. A temperature-sensitive bimetal disc, electrically   •  Power supplies

   and thermally isolated from the switch, is used to actuate      •  Appliances

   the normally-closed contacts. Contacts open when surface        •  Medical equipment

   or ambient temperatures increase to the operating set point     •  Water heaters

   of the calibrated metal disc. The entire switch is enclosed in

   a ceramic housing; the bimetal disc is retained by a metal      •  Office automation

   heat-conducting end cap. Due to the small size of this unit     •  Industrial equipment

   and the inherently low mass of the bimetal snap-action disc,    •  HVAC equipment

   response of this thermostat to temperature changes is

   extremely rapid, compared to other commercially available

   thermostatic devices. For increased sensitivity, an exposed

   bimetal disc may be specified. A variety of mounting

   brackets and terminals is available.

Table 5. 2450RC/2450RCH/2455RC           Series  Standard  Temperature     Characteristics

   Operating Temperature Range                                  Tolerance                   Standard Mean Differential

                                                 Open                      Close            °C [°F]

                                                 °C [°F]                   °C [°F]

                                                 ±4 [±7]                   ±6 [±10]         28 to 34 [50 to 60]

   0 °C to 26 °C                                 ±4 [±6]                   ±6 [±10]         22 to 27 [40 to 49]

   [32 °F to 79 °F]                              ±4 [±6]                   ±5 [±9]          17 to 22 [30 to 39]

                                                 ±4 [±6]                   ±5 [±8]          14 to 16 [25 to 29]

                                                 ±3 [±5]                   ±5 [±8]          8 to 14 [15 to 24]

                                                 ±5 [±9]                   ±8 [±15]         45 to 56 [81 to 100]

                                                 ±4 [±7]                   ±6 [±11]         34 to 45 [61 to 80]

   27 °C to 82 °C                                ±4 [±6]                   ±6 [±10]         28 to 34 [50 to 60]

   [80 °F to 180 °F]                             ±3 [±5]                   ±6 [±10]         22 to 27 [40 to 49]

                                                 ±3 [±5]                   ±5 [±9]          17 to 22 [30 to 39]

                                                 ±3 [±5]                   ±5 [±8]          8 to 16 [15 to 29]

                                                 ±6 [±10]                  ±8 [±15]         45 to 56 [81 to 100]

                                                 ±5 [±8]                   ±8 [±15]         35 to 45 [61 to 80]

   83 °C to 110 °C                               ±4 [±7]                   ±7 [±12]         28 to 34 [50 to 60]

   [181 °F to 230 °F]                            ±4 [±6]                   ±6 [±10]         22 to 27 [40 to 49]

                                                 ±4 [±6]                   ±5 [±9]          17 to 22 [30 to 39]

                                                 ±4 [±6]                   ±5 [±8]          8 to 16 [15 to 29]

6  www.honeywell.com/sensing
Table 6. 2450RC/2450RCH/2455RC     Series  Standard     Temperature  Characteristics     (continued)

Operating Temperature Range                             Tolerance                        Standard Mean Differential

                                              Open                   Close                            °C [°F]

                                              °C [°F]                °C [°F]

                                              ±7 [±12]               ±10 [±18]                        45 to 56 [81 to 100]

                                              ±5 [±9]                ±8 [±15]                         34 to 45 [61 to 80]

         111 °C to 149 °C                     ±5 [±8]                ±7 [±12]                         28 to 34 [50 to 60]

         [231 °F to 300 °F]                   ±4 [±7]                ±7 [±12]                         22 to 27 [40 to 49]

                                              ±4 [±7]                ±6 [±11]                         17 to 22 [30 to 39]

                                              ±4 [±7]                ±6 [±10]                         14 to 16 [25 to 29]

                                              ±8 [±15]               ±11 [±20]                        39 to 45 [71 to 80]

         150 °C to 170 °C                     ±6 [±10]               ±11 [±20]                        34 to 39 [61 to 70]

         [301 °F to 335 °F]                   ±6 [±10]               ±8 [±15]                         28 to 33 [50 to 60]

                                              ±6 [±10]               ±7 [±12]                         22 to 27 [40 to 49]

         171 °C to 220 °C                  ±14 [±25]                 ±14 [±25]                        51 to 56 [91 to 100]

         [336 °F to 425 °F]                ±11 [±20]                 ±11 [±20]                        39 to 50 [71 to 90]

                                              ±8 [±15]               ±11 [±20]                        28 to 39 [50 to 70]

         221 °C to 235 °C                  ±14 [±25]                 ±14 [±25]                        51 to 56 [91 to 100]

         [426 °F to 450 °F]                ±11 [±20]                 ±11 [±20]                        39 to 50 [71 to 90]

                                              ±8 [±15]               ±11 [±20]                        28 to 39 [50 to 70]

         236 °C to 260 °C                  ±14 [±25]                 ±14 [±25]                        31 to 56 [60 to 100]

         [451 °F to 500 °F]                ±11 [±20]                 ±11 [±20]                        28 to 50 [50 to 90]

Table 7. 2450RC/2450RCH/2455RC Series Specifications

Characteristic                  Parameter

Switch type                     SPST

Reset type                      automatic

Amperage                        See Tables 8, 9

Voltage                         120 Vac to 250 Vac

Operating temperature range     0 °C to 260 °C [32 °F to 500 °F]

Environmental exposure range    -20 °C to 287 °C [0 °F to 550 °F]

Materials:

Base                            ceramic

Contacts                        silver alloy

Terminals                       plated steel

Closure                         aluminum, brass, or stainless steel

Brackets                        stainless steel

Approvals                       •  2450RCH: 1,59 mm [0.0625 in] clearance through air and over surface; UL File  E36103;

                                   CSA File LR21048

                                •  2450RC: 1,59 mm [0.0625 in] clearance; UL file E36103; CSA File LR21048

                                •  2455RC: 6,35 mm [0.25 in] clearance; UL File E36103; CSA File LR21048

Weight                          6 g [0.21 oz] (does not include brackets or wire leads)

                                                                                         Honeywell Sensing and Control      7
Commercial Thermostats

Table 8. 2450RCH/2450RC Contact Ratings

           Life Cycles                   120 Vac                                   240 Vac

           100,000                       15 A resistive                    10 A resistive

           30,000                        125 VA pilot duty                 125 VA pilot duty

Table 9. 2455RC Contact Ratings

           Life Cycles                   120 Vac                                   240 Vac

           100,000                       15 A resistive                    10 A resistive

           100,000                       4.4 FLA 26.4 LRA                  2.2 FLA 13.2 LRA

           100,000                       125 VA pilot duty                 125 VA pilot duty

Note: Additional contact ratings are available, please contact Honeywell.

Figure 5. 2450RC/2450RCH/2455RC Basic Dimensions

   2450RC                        2450RCH                                   2455RC

8  www.honeywell.com/sensing
Figure 6. 2455RM/2450CM Series Phenolic or Ceramic Manual Reset Thermostats

The 2455RM (phenolic)/2450CM (ceramic) Series is a              All versions are UL/CSA, European     approved.

single pole, single throw, snap-acting, non-adjustable

thermostat. A temperature-sensitive bimetal disc, electrically  Potential applications include those  where a manual  reset  is

and thermally isolated from the switch, is used to actuate      desired, including:

the normally-closed contacts. Contacts open when surface

or ambient temperatures increase to the operating set point     •  Power supplies

of the calibrated bimetal disc. The entire switch is enclosed   •  Appliances

in a housing; the bimetal disc is retained by a metal heat-     •  Medical equipment

conducting end cap. The circuit remains open above the          •  Water heaters

room ambient temperature until the manual reset button is

depressed. Due to the small size of this unit and the           •  Office automation

inherently low mass of the bimetal snap-action disc,            •  Industrial equipment

response of this thermostat to temperature changes is           •  HVAC equipment

extremely rapid, compared to other commercially available

thermostatic devices. For increased sensitivity, an exposed

bimetal disc may be specified. A variety of mounting

brackets and terminals is available.

Table 10. 2455RM Series Standard Temperature Characteristics

Operating Temperature Range                                                              Tolerance °C [°F]

52 °C to 93 °C [125 °F to 200 °F]                                                        ±5 [±8]

94 °C to 121 °C [201 °F to 250 °F]                                                       ±6 [±10]

122 °C to 150 °C [251 °F to 302 °F]                                                      ±7 [±12]

Table 11. 2450CM Series Standard Temperature Characteristics

Operating Temperature Range                                                              Tolerance °C [°F]

52 °C to 93 °C [125 °F to 200 °F]                                                        ±5 [±8]

94 °C to 121 °C [201 °F to 250 °F]                                                       ±6 [±10]

122 °C to 149 °C [251 °F to 300 °F]                                                      ±7 [±12]

150 °C to 177 °C [301 °F to 350 °F]                                                      ±8 [±15]

177 °C to 204 °C [351 °F to 400 °F]                                                      ±10 [±18]

205 °C to 232 °C [401 °F to 450 °F]                                                      ±11 [±20]

                                                                                         Honeywell Sensing and Control           9
Commercial Thermostats

Table 12. 2455RM/2450CM Series  Specifications

Characteristic                           Parameter

Switch type                              SPST

Reset type                               manual

Amperage                                 15 A resistive at 6,000 cycles (UL); 16 A resistive  at  1000  cycles  (EU)

Voltage                                  120 Vac to 250 Vac

Operating temperature range              2455RM: 52 °C to 150 °C [125 °F to 302 °F]

                                         2450CM: 52 °C to 232 °C [125 °F to 450 °F]

Environmental exposure range             2455RM: -20 °C to 177 °C [0 °F to 350 °F]

                                         2450CM: -20 °C to 260 °C [0 °F to 500 °F]

Materials:

    Base                                 2455RM: phenolic; 2450CM: ceramic

    Contacts                             silver alloy

    Terminals                            2455RM: unplated brass, plated brass or steel;       2450CM:   plated  steel

    Closure                              aluminum, brass, or stainless steel

    Brackets                             stainless steel

Approvals                                UL File E36103, CSA File LR21048

Weight                                   6 g [0.21 oz] (does not include brackets or wire leads)

NOTICE

•   2455RM/2450CM thermostats are intended as a manual reset control. They are not to be used on applications where a limit

    thermostat is required unless back-up protection is provided. Units have been tested by UL for 1,000 cycles under load,

    5,000 cycles no load, and are not considered as limit devices.

•   This range of thermostats has an automatic reset function with manual override function.

•   Reset pin operation should not be performed above 70% of set point temperature.

Table 13. 2450CM/2455RM Contact Ratings

                Life Cycles                               120 Vac                                       240 Vac

                6,000                                     15 A resistive                                10 A resistive

                6,000                                  4.4 FLA 26.4 LRA                           2.2 FLA 13.2 LRA

                                                       125 VA pilot duty                          125 VA pilot duty

Note: Additional contact ratings are available, please consult Honeywell.

Figure 7. 2455RM/2455CM Basic Dimensions

2455RM                                                    2450CM

A Maximum travel of reset button on contact opening

B On contact closing

C Reset button

10  www.honeywell.com/sensing
Figure 8. 2455RD Series Phenolic Manual Reset

The 2455RD Series is a single pole, single throw, snap-         All versions are UL/CSA and European approved.

acting, non-adjustable thermostat. A temperature-sensitive

bimetal disc, electrically and thermally isolated from the      Potential applications include those where a manual  reset  is

switch, is used to actuate the normally-closed contacts.        desired, including:

Contacts open when surface or ambient temperatures

increase to the operating set point of the calibrated bimetal   •  Power supplies

disc. The entire switch is enclosed in a housing; the bimetal   •  Appliances

disc is retained by a metal heat-conducting end cap. The        •  Medical equipment

circuit remains open above the room ambient temperature         •  Water heaters

until the manual reset button is depressed. (These devices

are constructed with an additional steel disc so that they are  •  Office automation

manual reset only. They do not have an automatic reset.)        •  Industrial equipment

Due to the small size of this unit and the inherently low       •  HVAC equipment

mass of the bimetal snap-action disc, response of this

thermostat to temperature changes is extremely rapid,

compared to other commercially available thermostatic

devices. For increased sensitivity, an exposed bimetal disc

may be specified. A variety of mounting brackets and

terminals is available.

Table 14. 2455RD Series Standard Temperature Characteristics

Operating Temperature Range                                                              Tolerance °C [°F]

52 °C to 93 °C [125 °F to 200 °F]                                                        ±5 [±8]

94 °C to 121 °C [201 °F to 250 °F]                                                       ±6 [±10]

122 °C to 150 °C [251 °F to 302 °F]                                                      ±7 [±12]

                                                                                         Honeywell Sensing and Control          11
Commercial Thermostats

Table 15. 2455RD Series Specifications

Characteristic                          Parameter

Switch type                             SPST

Reset type                              manual

Amperage                                15 A resistive at 6,000 cycles (UL); 16 A resistive  at  1000  cycles (EU)

Voltage                                 120 Vac to 250 Vac

Operating temperature range             2455RD: 52 °C to 150 °C [125 °F to 302 °F]

Environmental exposure range            2455RD: -20 °C to 177 °C [0 °F to 350 °F]

Materials:

    Base                                phenolic

    Contacts                            silver alloy

    Terminals                           unplated brass, plated brass or steel

    Closure                             aluminum, brass, or stainless steel

    Brackets                            stainless steel

Approvals                               UL File E36103, CSA File LR21048

Table 16. 2455RD Contact Ratings

                Life Cycles                              120 Vac                                       240 Vac

                6000                                     15 A resistive                                10 A resistive

Note: Additional contact ratings are available, please consult Honeywell.

Figure 9. 2455RD Basic Dimensions

A Maximum travel of reset button on contact opening

B On contact closing

C Reset button

12  www.honeywell.com/sensing
Figure 10. Series 2455RBV Overmolded Automatic Reset Thermostats

The 2455RBV Series has a temperature-sensitive bimetal          This series is UL/CSA and European approved.

disc, electrically and thermally isolated from the switch that

is used to actuate the normally closed contacts. The            Potential applications include:

contacts open when surface or ambient temperatures              •  Automotive

increase to the operating set point of the calibrated bimetal   •  Industrial equipment

disc. The entire switch is enclosed in a phenolic or ceramic    •  HVAC

housing; the bimetal disc is retained by a metal heat-

conducting end cap. The unit is then encapsulated in epoxy.

Table 17. 2455RBV Series Standard Temperature Characteristics

Operating Temperature Range                                     Tolerance                        Standard Mean Differential

                             Open                                          Close                 °C [°F]

                             °C [°F]                                       °C [°F]

-12,2 °C to 26,7 °C          ±4 [±7]                                       ±6 [±10]              17 to 44 [30 to 80]

[10 °F to 80 °F]             ±3 [±6]                                       ±4 [±8]               14 to 28 [25 to 50]

                             ±3 [±5]                                       ±4 [±8]               11 to 22 [20 to 40]

27,2 °C to 105 °C            ±3 [±6]                                       ±6 [±10]              17 to 44 [30 to 80]

[81 °F to 221 °F]            ±3 [±5]                                       ±4 [±8]               11 to 28 [20 to 50]

                                                                                                 Honeywell Sensing and Control  13
Commercial Thermostats

Table 18. 2455RBV Series Specifications

Characteristic                            Parameter

Switch type                               SPST

Reset type                                automatic

Amperage                                  see Table 19

Voltage                                   120 Vac to 250 Vac

Operating temperature range               0 °C to 105 °C [32 °F to 221 °F]

Environmental exposure range              -18 °C to 126.6 °C [0 °F to 260 °F]

Materials:

    Boot                                  nylon, with epoxy filled or injection molded

    Base                                  internal 2455RC ceramic or 2455R phenolic

    Contacts                              silver alloy

    Terminals                             plated steel with wires

    Closure                               aluminum, brass, or stainless steel

    Brackets                              stainless steel

Approvals                                 UL File SA4469, CSA File LR21048.

Weight                                    6.5 g [0.23 oz] (does not include brackets or  wire  leads)

Table 19. 2455RBV Series Contact Ratings

               Life Cycles                                 120 Vac                                     240 Vac

                100,000                                    15 A resistive                              10 A resistive

                6,000                                   5.8 FLA 34.8 LRA                               2.9 FLA 17.4 LRA

                100,000                                 4.4 FLA 26.4 LRA                               2.2 FLA 13.2 LRA

                                                        125 VA pilot duty                              125 VA pilot duty

Note: Additional contact ratings are available, please contact Honeywell.

Figure 11. 2455RBV Basic Dimensions

                                                                            B

                                                A

                                                                            B

                                                                           18,54

                                                                           [0.730]

                                                        17,27  DIA.         0,020

                                                     [0.680]                [0.51]

A Specify wire gauge and insulation

B Specify dimension

14  www.honeywell.com/sensing
Figure 12. 2450A/2455RA Heat Detection Thermostats

   The 2450A/2455RA Series is a single pole, single throw,          All versions are UL approved.

   snap-acting, non-adjustable thermostat designed for easy

   mounting in devices such as fire alarms, security devices        Potential applications:

   and smoke detectors. A temperature-sensitive bimetal disc,       •    Smoke alarm/heat detectors in industrial, residential and

   electrically and thermally isolated from the switch, is used to       commercial

   actuate the normally-closed contacts. Contacts open when

   surface or ambient temperatures increase to the operating

   set point of the calibrated bimetal disc. Devices are UL

   recognized and designed for use in both photoelectric and

   ionization type smoke detectors. Thermostats are available

   with and without collectors and meet UL spacing

   requirements for 15 ft, 30 ft and 50 ft. They are available to

   open or close on a temperature rise of 47 °C [117 °F] to

   107 °C [225 °F]. Devices feature gold contacts for low

   voltage requirements and are epoxy sealed at the cap and

   terminal for long storage life of the application. Collectors

   are available in silver, black, beige, gold or bronze finishes.

   NOTICE

   Final approval of a fire detection system is determined by UL as outlined in UL #521 and UL #217 for the suitability of the

   combination of the thermostat (2450A/2455RA) and the user’s mounting base, together with its intended application of the total

   fire detection system. To assist the use with design and testing , a minimum of 0.25 in extension beyond the housing is

   recommended.

Table 20. 2450A/2455RA Series Standard Temperature Characteristics

                 Detection (Close on Rise)                                                   Release (Open  on Rise)

           Close                            Open                                     Open                             Close

           °C [°F]                          °C [°F]                      °C [°F]                                      °C [°F]

          47 ±3 [117±5]    30 min [85 min]                               57 ±3 [117 ±5]                     30 min [85 min]

          57 ±3 [135 ±5]   32 min [90 min]                               57 ±3 [135 ±5]                     32 min [90 min]

          69 ±3 [156 ±5]   32 min [90 min]                               69 ±3 [156 ±5]                     32 min [90 min]

          85 ±4 [185 ±7]   32 min [90 min]                               85 ±4 [185 ±7]                     32 min [90 min]

          107 ±4 [225 ±7]  32 min [90 min]                               107 ±4 [225 ±7}                    32 min [90 min]

Notes:

•  Additional switches can be provided as long as they fall between 47,2 °C to 107,2 °C [117 °F to 225      °F] close on rise or open  or

   rise.

•  Please consult Honeywell for tolerances and temperatures not listed.

                                                                                                   Honeywell Sensing and Control       15
Commercial Thermostats

Table 21. 2450A/2455RA Series  Specifications

Characteristic                     Parameter

Switch type                        SPST

Reset type                         automatic

Amperage                           3A

Voltage                            120 Vac

Operating temperature range        47,2 °C to 107,2 °C [117 °F to 225 °F]

Environmental exposure range       -0 °C to 150 °C [32 °F to 302 °F]

Materials:

    Base                           phenolic

    Contacts                       gold flash

    Terminals                      unplated brass, plated brass

    Closure                        aluminum

    Brackets                       aluminum

Approvals                          UL File S1015 and S1389; Guide USCV2       and   TAOZ2, UL Standard #521,  #217

Weight                             6 g [0.21 oz] (does not include brackets)

Figure 13. 2450A/2455RA Basic Dimensions

2450A                                          2455RA

Figure 14. 2450A/2455RA Collector              Figure 15. 2450A and 2455RA Spacing

B247                                           2450A: 4,6 m [15 ft]                 2455RA with B247A: 15,2   m [50  ft]

16  www.honeywell.com/sensing
Figure 16. 2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series “One Shot” Thermostats

The 2450R/2455R/2450RC/2455RC/2450HR/2450RCH                   All versions are UL/CSA approved and European approved.

Series “One Shot” is a single pole, single throw, snap-

acting, non-adjustable thermostat designed as a high limit     Potential applications include:

device for applications where automatically resettable         •  Power supplies

thermostats are not desirable. A temperature-sensitive         •  Appliances

bimetal disc, electrically and thermally isolated from the     •  Medical equipment

switch, is used to actuate the normally-closed contacts.       •  Water heaters

Contacts open when surface or ambient temperatures

increase to the operating set point of the calibrated bimetal  •  Office automation

disc. The entire switch is enclosed in a housing; the bimetal  •  Industrial equipment

disc is retained by a metal heat-conducting end cap. The       •  HVAC equipment

circuit remains open above the room ambient temperature

and will reset below -35 °C [-31 °F]. For increased

sensitivity, an exposed disc may be specified. A variety of

mounting brackets and terminals is available.

Table 22. 2450R/2455R/2450RC/2455RC/2450HR/2450RCH             Series “One Shot” Standard Temperature Characteristics

Operating Temperature Range                                                             Tolerance °C [°F]

52 °C to 93 °C [125 °F to 200 °F]                                                               5 [8]

94 °C to 121 °C [201 °F to 250°F]                                                               6 [10]

122 °C to 149 °C [251 °F to 300 °F]                                                             7 [12]

150 °C to 177 °C [301 °F to 350 °F]                                                             8 [15]

177 °C to 204 °C [351 °F to 400 °F]                                                             10 [18]

205 °C to 232 °C [401 °F to 450 °F]                                                             11 [20]

232 °C to 260 °C [451 °F to 500 °F]                                                             14 [25]

                                                                                                Honeywell Sensing and Control  17
Commercial Thermostats

Table 23. 2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series “One Shot” Specifications

   Characteristic                  Parameter

   Switch type                     SPST

   Reset type                      One Shot

   Amperage                        see Table 24

   Voltage                         120 Vac to 250 Vac

   Operating temperature range     2450R/2455R/2450HR/2450RCH: 52 °C to 150 °C [125 °F to 302 °F]

                                   2450RC/2455RC: 52 °C to 260 °C [125 °F to 500 °F]

   Environmental exposure range    2450R/2455R/2450HR/2450RCH: 17.8 °C to 177 °C [0 °F to 350 °F]

                                   2450RC/2455RC: 17.8 °C to 287 °C [125 °F to 550 °F]

   Materials:

    Base                           phenolic or ceramic

    Contacts                       silver alloy

    Terminals                      unplated brass, plated brass or steel

    Closure                        aluminum, brass, stainless steel

    Brackets                       stainless steel

   Approvals                       UL File E36103, CSA File LR43279

   Weight                          6 g [0.21 oz] (does not include brackets or lead wires)

Table 24. 2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series “One Shot” Contact Ratings

                Cycles             120 Vac                               240 Vac                   277 Vac

                   1               15 A resistive                        10 A resistive     10 A resistive

Notes:

•   Resets below -35 °C [-31 °F].

•   Additional contact ratings are available. Please consult Honeywell.

Figure 17. 2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series “One Shot” Basic Dimension

   2450R/22450RC “One Shot”                             2455R/2455RC “One Shot”

   2450HR “One Shot”                                    2450RCH “One Shot”

18  www.honeywell.com/sensing
REDI-TEMP THERMOSTATS

REDI-TEMP thermostats are pre-configured as shown and are readily available.

Figure 18. 3455RC REDI-TEMP Series (See page 6 for specifications and potential applications.)

                                                              3455RC                               B203S Moveable  Bracket

                                                                                                     23,80

                                                              32,26                                  [0.937]

                                                              [1.270]

                                                                                                                             2X 3,56 DIA

                                                                                                                             [0.140]

                                                                                          17,55

                                                                                          [0.691]

                                                                              2X 1,7 DIA

                                                                              [0.067]

                                                                                                     31,19

                                                                                                     [1.228]

                                                                              11,9

                                                   0.51                       [0.469]

                                                   [0.20]

Table 25. 3455RC  REDI-TEMP Series Open on Rise               Table 26. 3455RC REDI-TEMP Series Close on Rise

Catalog           Open       Open       Close      Close      Catalog                     Close      Close         Open      Open

Listing           Temp.      Tolerance  Temp.      Tolerance  Listing                     Temp.      Tolerance     Temp.     Tolerance

                  °C [°F]    °C [°F]    °C [°F]    °C [°F]                                °C [°F]    °C [°F]       °C [°F]   °C [°F]

3455RC-100-220    18 [65]    ±3 [±5]    -1 [30]    ±5 [±8]    3455RC-100-243              21 [70]    ±5 [±8]       2 [35]    ±3 [±5]

3455RC-100-221    24 [75]    ±3 [±5]    4 [40]     ±5 [±8]    3455RC-100-244              32 [90]    ±5 [±8]       16 [60]   ±3 [±5]

3455RC-100-222    29 [85]    ±3 [±5]    13 [55]    ±5 [±8]    3455RC-100-245              43 [110]   ±5 [±8]       27 [80]   ±3 [±5]

3455RC-100-223    35 [95]    ±3 [±5]    18 [65]    ±5 [±8]    3455RC-100-246              54 [130]   ±5 [±8]       38 [100]  ±3 [±5]

3455RC-100-224    41 [105]   ±3 [±5]    24 [75]    ±5 [±8]    3455RC-100-247              66 [150]   ±5 [±8]       49 [120]  ±3 [±5]

3455RC-100-225    46 [115]   ±3 [±5]    29 [85]    ±5 [±8]    3455RC-100-248              77 [170]   ±5 [±8]       60 [140]  ±3 [±5]

3455RC-100-226    52 [125]   ±3 [±5]    35 [95]    ±5 [±8]    3455RC-100-249              88 [190]   ±5 [±8]       71 [160]  ±3 [±5]

3455RC-100-227    57 [135]   ±3 [±5]    41 [105]   ±5 [±8]    3455RC-100-250              99 [210]   ±5 [±8]       82 [180]  ±4 [±6]

3455RC-100-228    63 [145]   ±3 [±5]    46 [115]   ±5 [±8]    3455RC-100-251              110 [230]  ±5 [±8]       93 [200]  ±4 [±6]

3455RC-100-229    68 [155]   ±3 [±5]    52 [125]   ±5 [±8]    Note: Materials and contact ratings are the same as those for 2455RC.

3455RC-100-230    73 [165]   ±3 [±5]    57 [135]   ±5 [±8]

3455RC-100-231    79 [175]   ±3 [±5]    63 [145]   ±5 [±8]

3455RC-100-232    85 [185]   ±3 [±5]    68 [155]   ±5 [±8]

3455RC-100-233    91 [195]   ±3 [±5]    73 [165]   ±5 [±8]

3455RC-100-234    96 [205]   ±4 [±6]    79 [175]   ±5 [±8]

3455RC-100-235    102 [215]  ±4 [±6]    85 [185]   ±5 [±8]

3455RC-100-236    107 [225]  ±4 [±6]    91 [195]   ±5 [±8]

3455RC-100-237    113 [235]  ±4 [±6]    96 [205]   ±5 [±8]

3455RC-100-238    118 [245]  ±4 [±6]    102 [215]  ±5 [±8]

3455RC-100-239    124 [255]  ±4 [±7]    107 [225]  ±5 [±8]

3455RC-100-240    135 [275]  ±4 [±7]    118 [245]  ±5 [±8]

3455RC-100-241    146 [295]  ±4 [±7]    129 [265]  ±5 [±8]

3455RC-100-242    157 [315]  ±6 [±10]   135 [275]  ±8 [±15]

                                                                                                   Honeywell Sensing and Control          19
Commercial Thermostats

MOUNTING HARDWARE

Figure 19. Brackets

B-201, B-201A, B-201B          B-203, B-203A, B-203B                B-205, B-205A

Stationary Surface             Movable Surface                      Air Stream

                                                                    A Enclosed B Exposed

B-203S                         B-206                                B-207

                                                                                               3,96

                                                                                               [0.156]

                                                                           43,05

                                                                           [1.695]                      34,11

                                                                                                        [1.343]

                                                                                    25.40 DIA

                                                                                    [1.000]

B-209                          B-210                                B-212, B-212A

                                                      8,71 R

                                                      [0.343]

                                                      12,70

                                                      [0.500]

                                        11,10         2X 3,73  DIA

                               3,18     [0.437]       [0.147]

                               [0.125]

B-213                          B-230                                B-239

20  www.honeywell.com/sensing
Figure 19.  Brackets  (Continued)

B-246                              B-249                     B-250

B-264

Figure 20. Brass Mounting Studs

B-220: 6-32                                          B240

B-221: 8-32

B-222: 10-24                                         6-32

B-223: 10-32                                         8-32

B-224: M3X0.5                                        10-32

B-225: M4X0.7                                        M3X0.5

B-226: M5X0.8                                        M4X0.7

B-227: M6X1.0                                        M5X0.8

A Undercut to minor diameter       B Specify length          C Specify thread

B-327                              B-901                     B-902

                                          4,1        5,0

                                          [0.062]    [0.17]

                                          M4 X 0.7

                                                             Honeywell Sensing  and  Control  21
Commercial Thermostats

Figure 21. Terminals

T-101                                        T-103                                   T-106                                   T-107

Horizontal Solder                            Special                                 Vertical Solder Inside                  Vertical Solder Outside

T-120                                        T-141                                   T-146                                   T-147

Special                                      Horizontal Weld                         1/4 in Quick Connect,   Horizontal      1/4 in Quick    Connect, Vertical

                            34,93

                           [1.375]                                                                                                                    15,85

                      25,40                                                                                                                           [0.624]

                      [1.000]

    4,90 DIA                                                                                                                 1,70 DIA

    [0.193]

                                                                                                                             [0.067]                  8,64

                                                                                                                                                      [0.340]

                               1,32 [0.052]

                               3,86 [0.152]

                               4.57 [0.180]

                               6.10 [0.240]

T-148                                        T-149                                   T-150                                   T-151

1/4 in Quick Connect, 45°                    3/16 in Quick Connect, Flat             3/16 in Quick Connect. Vertical         3/16 in Quick Connect, 45°

                               1,70 DIA      terminal thickness = 0.5 mm [0.020 in]  terminal thickness = 0.5 mm [0.020 in]

                             [0.067]

             27,59

             [1.086]

                      45°

                      6,16

                      [0.242]

T-161                                        T-162                                   T-164                                   T-165

T-168                                        T-169                                   T-170                                   T-178

                                                                                                                                             12,70

                                                                                                                                             [0.500]

                                                                                                                                                      62,18

                                                                                                                                                      [2.448]

                                                                                                                                             3,18

                                                                                                                                             [0.125]

                                                                                                                                      2,79

                                                                                                                                    [0.110]  1,27

                                                                                                                                             [0.050]

22     www.honeywell.com/sensing
Figure 21.  Terminals  (Continued)

T-179                               T-188                                   T-806                                   T-807

                                                                            Vertical Weld Inside                    Vertical Weld  Outside

                                           12,90    2,54

                                           [0.508]  [0.100]

T-846                               T-849                                   T-850                                   T-899

Horizontal                          3/16 in Quick Connect, Flat             3/16 in Quick Connect, Vertical

            32,5                    terminal thickness = 0.8 mm [0.032 in]  terminal thickness = 0.8 mm [0.032 in]

            [1.28]                                                                                                                          8,7

                                                                                                                           4,9     [0.34]

                                                                                                                    [0.19]

            A

A = 2X threaded for M3 screw

                                                                                                                    Honeywell Sensing and Control  23
WARNING                                                                            WARNING

PERSONAL INJURY                                                    MISUSE OF DOCUMENTATION

DO NOT USE these products as safety or emergency stop              •               The information presented in this product sheet is for

devices or in any other application where failure of the                           reference only. Do not use this document as a product

product could result in personal injury.                                           installation guide.

Failure to comply with these instructions could result in          •               Complete installation, operation, and maintenance

death or serious injury.                                                           information is provided in the instructions supplied with

                                                                                   each product.

                                                                   Failure to comply with these instructions could result in

WARRANTY/REMEDY                                                    death or serious injury.

Honeywell warrants goods of its manufacture as being free of

defective materials and faulty workmanship. Honeywell’s

standard product warranty applies unless agreed to otherwise       SALES AND SERVICE

by Honeywell in writing; please refer to your order                Honeywell serves its customers through a worldwide network

acknowledgement or consult your local sales office for specific    of sales offices, representatives and distributors. For

warranty details. If warranted goods are returned to Honeywell     application assistance, current specifications, pricing or name

during the period of coverage, Honeywell will repair or replace,   of the nearest Authorized Distributor, contact your local sales

at its option, without charge those items it finds defective. The  office or:

foregoing is buyer’s sole remedy and is in lieu of all other       E-mail: info.sc@honeywell.com

warranties, expressed or implied, including those of               Internet: www.honeywell.com/sensing

merchantability and fitness for a particular purpose. In no

event shall Honeywell be liable for consequential, special,        Phone and Fax:

or indirect damages.                                               Asia Pacific    +65 6355-2828

                                                                                   +65 6445-3033 Fax

While we provide application assistance personally, through        Europe          +44 (0) 1698 481481

our literature and the Honeywell web site, it is up to the                         +44 (0) 1698 481676 Fax

                                                                   Latin America +1-305-805-8188

customer to determine the suitability of the product in the                        +1-305-883-8257 Fax

application.                                                       USA/Canada +1-800-537-6945

                                                                                   +1-815-235-6847

Specifications may change without notice. The information we                       +1-815-235-6545 Fax

supply is believed to be accurate and reliable as of this

printing. However, we assume no responsibility for its use.

Sensing and Control

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422                   009053-2-EN  IL50  GLO   Printed in USA

www.honeywell.com                         September 2009

                                          Copyright © 2009 Honeywell International Inc. All rights reserved.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Honeywell:

2450CM 00020410  2450CM 00820670  2450CM 00950158  2450CM 02150037  2450CM 05170009  2450CM

80020577  2450CM 80020620  2450CM 80020671  2450CM 80020691  2450CM 80040416  2450CM 80820817

2450CM 80821030  2450CM 81000460  2450CM 82090117  2450CM 82090123  2450CM 83250021  2450CM

86750001  2450CMG81840033  2450CMG86980002  2450CMN80821029         2450HR 00010484  2450RC 00040225

2455RBV01170246  2455RBV01170281  2455RBV81170399  2455RBV82290018  2455RBV83630009  2455RC

00580071  2455RC 00820321  2455RC 80820961  2455RC 81740206  2455RC260040208  2455RC350020533

2455RC350020675  2455RC350020697  2455RC350040503  2455RC350040506  2455RC350040508

2455RC350040510  2455RC350580177  2455RC350950201  2455RC350950223  2455RC356380025

2455RC356780014  2455RM 80820759  2455RM 80980239  2455RM 82850114  2455RM 82850115

2455RMG81460089  2455RC-91000373  2450CM 00580076  2455R--90140921  2455R--01000076  2455R--90020515

2455R--90040874  2455R--00820716  2455R--00820923  2455R--00820715  2455R--90980116  2455R--00820712

2455R--90980491  2455R--09300015  2455R--90750872  2455R--00750822  2455R--01490979  2455R--90820462

2455R--03260915  2455R--04170909  2455R--03260911  2455R--94090904  2455R--01000073  2455R--01000075

2455R--99030011  2455R--90980437  2455R--01000086  2455R--00820191  2455R--01000078  2455R--94280011

2455R--93260812  2455R--90020674  2455R--00980928  2455R--00820714  2455R--00980790  2455R--00820235

2455R--90820464  2455R--09130070  2455R--01000849  2455RC-90820465  2455R--01000079  2455R--90820365

2455R--01000089  2455R--90820461  2455R--01360906  2455R--90980459  2455R--95000900  2455R--91470925

2455R--90870290  2455R--90820463  2455R--79580026  2455R--02980850
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved