  Safety Isolation System

ElectroGuard Overview . . . . . . . . . . . . . . . . . . . . . . 12-2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-2
Non Combination Systems (for North America) . . . 12-4
Non Combination Systems

  (Outside North America) . . . . . . . . . . . . . . . . . . . . 12-5
Combination Systems with Fusible Disconnect

  (for North America) . . . . . . . . . . . . . . . . . . . . . . . . . 12-6
Combination Systems with Fusible Disconnect

  (Outside North America) . . . . . . . . . . . . . . . . . . . . 12-7
Combination Systems with Thermal-magnetic

  Circuit Breaker (for North America) . . . . . . . . . . 12-10
Combination Systems with Thermal-magnetic Circuit
Breaker (Outside North America). . . . . . . . . . . . . . 12-12
Optional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-15
Typical Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . 12-18
Wire Length Considerations. . . . . . . . . . . . . . . . . . . 12-18
Ordering Instructions . . . . . . . . . . . . . . . . . . . . . . . 12-19
Safety Isolation System                                                     Status Communication Capability to a Remote PLC

ElectroGuard                                                                Optional Remote I/O via Flex modules. Communication can be
                                                                               via the DeviceNet communication platform or the Remote I/O
Overview                                                                       communication platform.

The ElectroGuard Safety Isolation System is used in place of a              Available from 23-1200 Amperes.
disconnect switch for Lockout and Tagout (LOTO). It uses power
contactors and Remote Lockout Stations to accomplish LOTO.                  Specifications

Isolating the electrical energy usually involves calling an electrician to  Approvals                        CULUS Listed Industrial Control Panel;
turn "Off " the main disconnecting means. The electrician would             Standards                        TUV Rheinland certified; CE marked
then perform LOTO of the disconnecting means operating handle.                                               for all applicable directives

This same procedure is required to perform cleaning, maintenance,                                            IEC/EN 60204-1; IEC/EN 60439-1;
setup, lubrication or adjustment. Machines or processes with                                                 Category 4 to International Standard
multiple access points may require operator/maintenance                                                      EN 954-1/ISO 13849-1; 98/37/EC
intervention several times a shift (perhaps as often as 60 times per                                         Machinery Directive; 89/336/EC EMC
shift).                                                                                                      Directive; 73/23/EC Low Voltage
                                                                                                             Directive; Fulfils the function of an
To perform these activities, the operator/maintenance person may                                             energy isolating device in accordance
be required to place part of his or her body into an area not accessed                                       with the conditions set forth in the
during normal operation. This may cause serious or fatal injury if                                           FedOSHA letter of interpretation
LOTO procedures are not followed.                                                                            pertaining to Section 1910.147(b);
                                                                                                             Cal/OSHA 3314.
The ElectroGuard Safety Isolation System allows the machine
operator to safely and quickly accomplish LOTO with dramatically            Estimated Component Life         250,000 operations
reduced downtime.                                                                Remote Lockout Station
                                                                                        Power Contactors     23A - 85A: 2,000,000 operations
Provides Energy Isolation                                                         (Isolation & Grounding)
Power isolation accomplished by means of contactors rather than                                            110A-1200A: 1,000,000 operations
                                                                            Environmental
   disconnect switches.                                                              Storage Temperature     -10C...+60C (14F...140F)
Uses redundant, independent and self-monitoring circuits to
                                                                                  Operating Temperature      0C...+40C (32F...104F) (Ambient)
   detect a system fault.                                                                Relative Humidity,
Prevents accumulation of faults in order to maintain the integrity                       Non condensing    90% Relative Humidity

   of the safety system.                                                    Power Panel Construction         Tamper-resistant Control Module
Tamper-resistant design.
Convenient Remote Lockout Station                                           Remote Lockout Station           23A-85A systems support up to 4
Allows remote isolation of the electrical power to the machine or         Construction                     Remote Lockout Stations without an
                                                                                                             Expansion Module
   process--machine operator simply turns "Off " a Remote                   Expansion Module
   Lockout Station.                                                         Construction                     110A-1200A systems support up to 6
A light on the Remote Lockout Station indicates that the three-                                            Remote Lockout Stations without an
   phase power source to the machine or process has been isolated.          Safety Isolation Sys. Inputs     Expansion Module
   No Light Means No Entry.                                                          Standard Inputs from
If a fault occurs in the Safety Isolation System, the "System                      Optional Inputs from    Control Module with viewing window
   Isolated" light on the Remote Lockout Stations will not                          Rockwell Automation      for visual check of status indicator lights
   illuminate.                                                                              Safety Products
Easy Lockout/Tagout.                                                                                       Top and bottom 25.4mm (1.0in)
Certified by TUV to meet requirements of Category 4                         System Operational Limits        conduit entry (removable plug in
Certified by TUV to meet Category 4, the most stringent safety                                             bottom conduit hole)
   category defined within International Standard EN 954-1/ISO
   13849-1.                                                                                                  Sealing provision for tamper-resistance
Subjected by TUV to rigorous third party testing and verification
   of the Failure Mode & Effect Analysis (FMEA).                                                             Operating handle accepts up to 3
                                                                                                             padlocks

                                                                                                             4 port--supports up to 4 lockout
                                                                                                             stations

                                                                                                                allows the systems to
                                                                                                                  accommodate up to 24 Remote
                                                                                                                  Lockout Stations

                                                                                                             10 port--supports up to 10 lockout
                                                                                                             stations

                                                                                                                allows the systems to
                                                                                                                  accommodate up to 60 Remote
                                                                                                                  Lockout Stations

                                                                                                             Window for viewing status indicator
                                                                                                             lights; Sealed for tamper-resistance

                                                                                                             Remote Lockout Stations

                                                                                                             Safety Mats,
                                                                                                             Light Curtains,
                                                                                                             E-Stop Stations,
                                                                                                             Proximity Switches,
                                                                                                             Photo Switches

                                                                                                             +10%, -15% of the line voltage

                                                                             Use of any of these input devices will not meet Lockout/Tagout (LOTO)
                                                                                requirements.

12-2
                                                                                                                Safety Isolation System

                                                                                                                   ElectroGuard

                                                                                                                                     Overview

Principle of Operation

                                        Power Circuit                                                           After using the normal stopping
                                                                                                                method of the machine or process,
                                  1IC 2IC                                                                       the machine operator turns a
                                                                                                                Remote Lockout Station handle
Incoming                                                                  To Motor            To Loads          from the "On" to "Off " position.
3 Phase                                                                  Controllers                            The station signals the isolation
Power                                                                                                          contactors (1IC and 2IC) to drop
                                                                                                                out and isolate the supply voltage
                     H1  H2            GC                                                                       from the loads (see Control
                              Trans.                                                                            Circuit).

               X1 Control Power X2                                       Voltage                                When system residual voltage
                                                                         Decay                                  decays to pre-determined levels,
Disconnecting                Grd                                         Relays                                 the grounding contactor (GC) is
                                                                         (VDR)                                  energized, connecting the load to
Means/Branch                                                                                                    ground (see Power Circuit). The
Circuit Protection                                                                                              grounding contactor (GC) is
                                                                                                                electrically and mechanically
          Remote Lockout Station       Control Circuit                                                          interlocked with the isolation
                                                                                                                contactors (1IC and 2IC).
          Off            On                                 GC
                                                                                                                The "System Isolated" Light will
                                                                    GC   1IC                                    now illuminate on the Remote
                                                                                                                Lockout Station to indicate the
                                                                                                  Mechanically  system is isolated. The machine
                                                                                                   Interlocked  operator then Locks-Out and
                                                                         2IC                                    Tags-Out the station in the "Off "
                                                                                                                position.

                                  VDR      1IC                      2IC                       1IC, 2IC, &
                                                                                              GC are
                                                                         GC

                                                                                              mechanically

                                                                                              and electrically

                                                                                              interlocked

                                  GC       1IC                      2IC  System Isolated (*)

                                                                         (*) = "On" when the Remote

                                                                         Lockout Station switch is "Off"

Available factory installed within the ElectroGuard as an option.

Optional Features

Four (4) or ten (10) port Expansion Modules to permit additional Remote
   Lockout Stations to be used (see page 12-16 for details).

Pneumatic Isolation Module to isolate pneumatic energy (see page 12-15 for
   details).

Status communication to a remote PLC (see page 12-17 for details).
Fusible disconnect switch (Bulletin 2032) or thermal-magnetic circuit breaker

   (Bulletin 2033) to provide branch circuit protection.

                                                                                                                Optional Pneumatic Isolation Module

                                                                                                                                                     12-3
Safety Isolation System

ElectroGuard

Non Combination Systems

                                                                  +              One or More Remote Lockout Stations
                                                                                        (conduit hub not included)
                       Power Panel

Product Selection: For North America (see page 12-19 for Ordering Instructions)

         3-Phase Max. Hp Rating (60Hz)                                           Catalogue Number

Ampere   200V  230V            460V        575V  Type 1 General    Type 12       Type 12 Motor          Type 4                   Type 4X
Rating    5    7.5              15          15      Purpose      Dust tight     Control Centre      Watertight                Watertight
(AC-3)    10    15              30          30     Enclosure     Enclosure      Type Enclosure     Painted Steel            Stainless Steel
           25    30              60          60                                   (with bussing)      Enclosure                 Enclosure
    23     40    40              75         100   2031-A0023A                                                                2031-A0023C
    43     50    60             150         150   2031-A0043A     2031-A0023J    2031-!0023J        2031-A0023F              2031-A0043C
    85     60    75               -         200   2031-A0085A                                                                2031-A0085C
   110          125             250         300   2031-A0110A     2031-A0043J    2031-!0043J        2031-A0043F              2031-A0110C
   180    100   175             350         400   2031-A0180A                                                                2031-A0180C
   210    150   250             500         600   2031-A0210A     2031-A0085J    2031-!0085J        2031-A0085F              2031-A0210C
   300    200   300             600         700   2031-A0300A                                                                2031-A0300C
   420    250   450             900         900   2031-A0420A     2031-A0110J    2031-!0110J        2031-A0110F              2031-A0420C
   630    450                                    2031*-A0630A                                                                2031*-A0630C
   860                                           2031*-A0860A     2031-A0180J    2031-!0180J        2031-A0180F              2031*-A0860C
  1200                                           2031*-A1200A                                                                2031*-A1200C
                                                                  2031-A0210J    2031-!0210J        2031-A0210F

                                                                  2031-A0300J    2031-!0300J        2031-A0300F

                                                                  2031-A0420J    2031-!0420J        2031-A0420F

                                                                  2031*-A0630J   2031-!0630J        2031*-A0630F

                                                                  2031*-A0860J   2031-!0860J        2031*-A0860F

                                                                  2031*-A1200J   2031-!1200J        2031*-A1200F

To order the Time Delay feature, add the following Catalogue String to the end of the Catalogue Number shown in the
table:

Factory set 30 second time delay feature:           -1TD

Example: Catalogue Number 2031-A0180A becomes Catalogue Number 2031-A0180A-1TD to include the time delay feature.

* Input Power Feed Catalogue Number Code
The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.

Example: Catalogue Number 2031*-A0630J becomes Catalogue Number 2031T-A0630J for a "Top Feed" input power requirement.

             Input Power Feed              Catalogue Number Code
Top Feed                                                   T
Bottom Feed                                                B

! Bussing Designation

The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below.
Example: Catalogue Number 2031-!0085J becomes Catalogue Number 2031-M0085J for "600A Line Side Incoming Bus and Outgoing Power Cables"

bussing designation.

               Type of Bussing                                    Catalogue Number Code

600A Line Side Incoming Bus and Outgoing Power Cables                         M

1200A Line Side Incoming Bus and Outgoing Power Cables                        S

Line Side Incoming Power Cables and 600A Load Side Outgoing Bus               F

Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus              B

Input Line Voltage Code

The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.

Example: Catalogue Number 2031-A0085J becomes Catalogue Number 2031-A0085JB for a 480V 60Hz Input Line Voltage application.

         Input Line Voltage                208V 60Hz 240V 60Hz 480V 60Hz 600V 60Hz

Voltage Code for Catalogue Number                H        A          B                   C

Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine

    operator to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the "Off"
    position. Consult your local Rockwell Automation sales office for other time settings.
Bus Type: Copper with tin plating. Consult factory for other types of bussing.

12-4
                                                                                                Safety Isolation System

                                                                                                  ElectroGuard

                                                                                            Non Combination Systems

Product Selection: Remote Lockout Station

                                                                     Catalogue Number

  "System Isolated"    Type 1 General               Type 12 Dust tight  Type 4 Watertight Painted  Type 4X Watertight Stainless
      Light Colour   Purpose Enclosure                    Enclosure            Steel Enclosure               Steel Enclosure

White                   2030-RLSAW                      2030-RLSJW            2030-RLSFW                      2030-RLSCW

Product Selection: For Outside of North America (see page 12-19 for Ordering Instructions)

             3-Phase Max. kW Rating (50Hz)                                 Catalogue Number

Ampere       230V    400V     500V         600V     IP 30 Enclosure     IP 54 Enclosure   IP 54 Motor Control        IP 65 Enclosure
Rating       7.5      11       11           11      2031-C0023P                         Centre Type Enclosure        2031-C0023W
(AC-3)        13      22       22           22      2031-C0043P                                                      2031-C0043W
               25      45       45           45      2031-C0085P                                 (w/bussing)          2031-C0085W
    23         32      55       63          100      2031-C0110P                                                      2031-C0110W
    43         55      90      110          160      2031-C0180P        2031-C0023H         2031-!0023H               2031-C0180W
    85         63     110      150          200      2031-C0210P                                                      2031-C0210W
   110         90     160      200          300      2031-C0300P        2031-C0043H         2031-!0043H               2031-C0300W
   180        132     220      300          425      2031-C0420P                                                      2031-C0420W
   210        200     355      450          500      2031*-C0630P       2031-C0085H         2031-!0085H              2031*-C0630W
   300        250     500      560          600      2031*-C0860P                                                    2031*-C0860W
   420        391     710      888                   2031*-C1200P       2031-C0110H         2031-!0110H              2031*-C1200W
   630                                     1043
   860                                                                  2031-C0180H         2031-!0180H
  1200
                                                                        2031-C0210H         2031-!0210H

                                                                        2031-C0300H         2031-!0300H

                                                                        2031-C0420H         2031-!0420H

                                                                        2031*-C0630H        2031-!0630H

                                                                        2031*-C0860H        2031-!0860H

                                                                        2031*-C1200H        2031-!1200H

To order the Time Delay feature, add the following Cat. String to the end of the Cat. No. shown in the table:

Factory set 30 second time delay feature:                               -1TD

Example: Catalogue Number 2031-C0180Hbecomes Catalogue Number 2031-C0180H-1TD to include the time delay feature.

* Input Power Feed Catalogue Number Code

The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.

Example: Catalogue Number 2031*-C0630H becomes Catalogue Number 2031T-C0630H for a "Top Feed" input power requirement.

          Input Power Feed                 Catalogue Number Code

Top Feed                                                T

Bottom Feed                                             B

! Bussing Designation

The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table.
Example: Catalogue Number 2031-!0085H becomes Catalogue Number 2031-E0085H for "600A Line Side Incoming Bus and Outgoing Power Cables"

bussing designation.

                     Type of Bussing                                 Catalogue Number Code

600A Line Side Incoming Bus and Outgoing Power Cables                   E

1200A Line Side Incoming Bus and Outgoing Power Cables                  D

Line Side Incoming Power Cables and 600A Load Side Outgoing Bus         H

Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus        R

Input Line Voltage Code

The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.

Example: Catalogue Number 2031-C0085P becomes Catalogue Number 2031-C0085PN for a 380V 50Hz Input Line Voltage application.

          Input Line Voltage               220V 50HZ 380-400V 50Hz 400-415V 50Hz 440V 50Hz 500V 50Hz                         550V 50Hz
                                                                                                                                   C
Voltage Code for Catalogue Number                A                N           G             B                     M

Product Selection: Remote Lockout Station

                                                                        Catalogue Number

"System Isolated" Light Colour                   IP 30 Enclosure        IP 54 Enclosure                  IP 65 Enclosure

Green                                               2030-RLSPG          2030-RLSHG                       2030-RLSWG

Safety Isolation Systems rated up through 85A can support a maximum of four (4) Remote Lockout Stations (RLS).

    Systems rated from 110A - 1200A can support a maximum of six (6) RLS. If additional RLS are required, order the optional Expansion Module(s) (see page 12-16).
Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine

    operator to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the "Off"

    position. Consult your local Rockwell Automation sales office for other time settings.
Bus Type: Copper with tin plating. Consult factory for other types of bussing.

                                                                                                                             12-5
Safety Isolation System

ElectroGuard

Combination Systems with Fusible Disconnect Switch

Product Selection: For North America (see page 12-19 for Ordering Instructions)

          3-Phase Max. Hp                                                    Catalogue Number
            Rating (60Hz)

                              Fuse                                            Type 12 Motor         Type 4          Type 4X
                                                                              Control Centre     Watertight       Watertight
Amp.                          Clip Type 1 General                             Type Enclosure    Painted Steel   Stainless Steel
                                                                               (with bussing)     Enclosure        Enclosure
Rating 200 230 460 575 Rating/              Purpose          Type 12 Dust
(AC-3) V V V V Type                        Enclosure        tight Enclosure

                               30A         2032-A0023A-24J  2032-A0023J-24J   2032-!0023J-24J  2032-A0023F-24J  2032-A0023C-24J
                              Class J
23 5 7.5 15 15
                               60A
                              Class J      2032-A0023A-25J  2032-A0023J-25J   2032-!0023J-25J  2032-A0023F-25J  2032-A0023C-25J

                               60A         2032-A0043A-25J  2032-A0043J-25J   2032-!0043J-25J  2032-A0043F-25J  2032-A0043C-25J
                              Class J
43 10 15 30 30
                              100A
                              Class J      2032-A0043A-26J  2032-A0043J-26J   2032-!0043J-26J  2032-A0043F-26J  2032-A0043C-26J

                              100A         2032-A0085A-26J  2032-A0085J-26J   2032-!0085J-26J  2032-A0085F-26J  2032-A0085C-26J
                              Class J
85 25 30 60 60
                              200A
                              Class J      2032-A0085A-27J  2032-A0085J-27J   2032-!0085J-27J  2032-A0085F-27J  2032-A0085C-27J

                              200A         2032-A0110A-27J  2032-A0110J-27J   2032-!0110J-27J  2032-A0110F-27J  2032-A0110C-27J
                              Class J
110 40 40 75 100
                              400A
                              Class J      2032-A0110A-28J  2032-A0110J-28J   2032-!0110J-28J  2032-A0110F-28J  2032-A0110C-28J

                              200A         2032-A0180A-27J  2032-A0180J-27J   2032-!0180J-27J  2032-A0180F-27J  2032-A0180C-27J
                              Class J
180 50 60 125 150
                              400A
                              Class J      2032-A0180A-28J  2032-A0180J-28J   2032-!0180J-28J  2032-A0180F-28J  2032-A0180C-28J

210       60   75   150  200  400A         2032-A0210A-28J  2032-A0210J-28J   2032-!0210J-28J  2032-A0210F-28J 2032-A0210C-28J
                              Class J

                              400A         2032-A0300A-28J  2032-A0300J-28J   2032-!0300J-28J  2032-A0300F-28J  2032-A0300C-28J
                              Class J
300 75 125 250 300
                              600A
                              Class J      2032-A0300A-29J  2032-A0300J-29J   2032-!0300J-29J  2032-A0300F-29J  2032-A0300C-29J

                              600A         2032-A0420A-29J  2032-A0420J-29J   2032-!0420J-29J  2032-A0420F-29J  2032-A0420C-29J
                              Class J
420 150 175 350 400
                               800A
                              Class L      2032-A0420A-30L  2032-A0420J-30L   2032-!0420J-30L  2032-A0420F-30L  2032-A0420C-30L

                               800A        2032*-A0630A-30L 2032*-A0630J-30L  2032-!0630J-30L  2032*-A0630F-30L 2032*-A0630C-30L
                              Class L
630 200 250 500 600
                              2000A
                              Class L      2032*-A0630A-34L 2032*-A0630J-34L  2032-!0630J-34L  2032*-A0630F-34L 2032*-A0630C-34L

860       250  300  600  700  2000A        2032*-A0860A-34L 2032*-A0860J-34L  2032-!0860J-34L  2032*-A0860F-34L 2032*-A0860C-34L
                              Class L

1200      450  450  900  900  2000A        2032*-A1200A-34L 2032*-A1200J-34L  2032-!1200J-34L  2032*-A1200F-34L 2032*-A1200C-34L
                              Class L

To order the Time Delay feature, add the following Catalogue String to the end of the Cat. No. shown in the table:

Factory set 30 second time delay feature:  -1TD

Example: Catalogue Number 2032-A0180A-27J becomes Catalogue Number 2032-A0180A-27J-1TD to include the time delay feature.

* Input Power Feed Catalogue Number Code

The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.

Example: Catalogue Number 2032*-A0630J-30L becomes Catalogue Number 2032T-A0630J-30L for a "Top Feed" input power requirement.

          Input Power Feed                 Catalogue Number Code

Top Feed                                   T

Bottom Feed                                B

Power fuses are not included with the disconnect switch. Select power fuses in accordance with applicable local codes.
Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine operator

    to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the "Off" position.

    Consult your local Rockwell Automation sales office for other time settings.

12-6
                                                                                                              Safety Isolation System

                                                                                                    ElectroGuard

                                                                  Combination Systems with Fusible Disconnect Switch

! Bussing Designation

The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below.
Example: Cat. No. 2032-!0085J-26J becomes Cat. No. 2032-M0085J-26J for "600A Line Side Incoming Bus and Outgoing Power Cables" bussing

designation.

                    Type of Bussing                               Catalogue Number Code

600A Line Side Incoming Bus and Outgoing Power Cables                         M

1200A Line Side Incoming Bus and Outgoing Power Cables                        S

Line Side Incoming Power Cables and 600A Load Side Outgoing Bus               F

Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus              B

Input Line Voltage Code

The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.

Example: Catalogue Number 2032-A0085J-26J becomes Catalogue Number 2032-A0085JB-26J for a 480V 60Hz Input Line Voltage application.

Input Line Voltage                    208V 60Hz                   240V 60Hz              480V 60Hz  600V 60Hz

Voltage Code for Catalogue Number         H                                A                 B      C

Product Selection: Remote Lockout Station

                                                                    Catalogue Number

"System Isolated"       Type 1 General                Type 12 Dust tight     Type 4 Watertight Painted Type 4X Watertight Stainless
     Light Colour      Purpose Enclosure                     Enclosure
                                                                                 Steel Enclosure    Steel Enclosure
White                     2030-RLSAW
                                                        2030-RLSJW               2030-RLSFW         2030-RLSCW

Bus Type: Copper with tin plating. Consult factory for other types of bussing.
Safety Isolation Systems rated up through 85A can support a maximum of four (4) Remote Lockout Stations (RLS).

    Systems rated from 110A - 1200A can support a maximum of six (6) RLS. If additional RLS are required, order the optional Expansion Module(s) (see page 12-16).

                                                                                                                                               12-7
Safety Isolation System

ElectroGuard

Combination Systems with Fusible Disconnect Switch

Product Selection for Outside of North America (see page 12-19 for Ordering Instructions)

        3-Phase Max. kW Rating                                Catalogue Number
                    (50Hz)

Amp.    230V  400V  500V           Fuse Clip                   IP 54 Enclosure   IP 54 Motor Control     IP 65 Enclosure
Rating   5.5    11    11             Rating/                  2032-C0023H-23B   Centre Type Enclosure  2032-C0023W-23B
(AC-3)    11    22    22                                      2032-C0023H-24B                          2032-C0023W-24B
          22    45    45  600V Type  IP 30 Enclosure          2032-C0023H-25B         (with bussing)   2032-C0023W-25B
   23     32    55    63           20A BS 88 2032-C0023P-23B  2032-C0023H-25D       2032-!0023H-23B    2032-C0023W-25D
          45    90   110           32A BS 88 2032-C0023P-24B  2032-C0043H-25B       2032-!0023H-24B    2032-C0043W-25B
   43     63   110   150                                      2032-C0043H-25D       2032-!0023H-25B    2032-C0043W-25D
          90   160   200    11                                2032-C0043H-26B       2032-!0023H-25D    2032-C0043W-26B
   85    132   220   300           63A BS 88 2032-C0023P-25B  2032-C0043H-26D       2032-!0043H-25B    2032-C0043W-26D
         200   355   450            63A DIN 2032-C0023P-25D   2032-C0085H-26B       2032-!0043H-25D    2032-C0085W-26B
  110                              63A BS 88 2032-C0043P-25B  2032-C0085H-26D       2032-!0043H-26B    2032-C0085W-26D
                                    63A DIN 2032-C0043P-25D   2032-C0085H-27B       2032-!0043H-26D    2032-C0085W-27B
  180                                                         2032-C0085H-27D       2032-!0085H-26B    2032-C0085W-27D
                            22                                2032-C0110H-26B       2032-!0085H-26D    2032-C0110W-26B
  210                             100A BS 88 2032-C0043P-26B  2032-C0110H-26D       2032-!0085H-27B    2032-C0110W-26D
                                   100A DIN 2032-C0043P-26D   2032-C0110H-27B       2032-!0085H-27D    2032-C0110W-27B
  300                             100A BS 88 2032-C0085P-26B  2032-C0110H-27D       2032-!0110H-26B    2032-C0110W-27D
                                   100A DIN 2032-C0085P-26D   2032-C0110H-28D       2032-!0110H-26D    2032-C0110W-28D
  420                                                         2032-C0180H-27B       2032-!0110H-27B    2032-C0180W-27B
  630                       45                                2032-C0180H-28D       2032-!0110H-27D    2032-C0180W-28D
                                  200A BS 88 2032-C0085P-27B  2032-C0180H-29B       2032-!0110H-28D    2032-C0180W-29B
                                   160A DIN 2032-C0085P-27D   2032-C0180H-29D       2032-!0180H-27B    2032-C0180W-29D
                                   100A BS88 2032-C0110P-26B  2032-C0210H-27B       2032-!0180H-28D    2032-C0210W-27B
                                   100A DIN 2032-C0110P-26D   2032-C0210H-28D       2032-!0180H-29B    2032-C0210W-28D
                                                              2032-C0210H-29B       2032-!0180H-29D    2032-C0210W-29B
                           100 200A BS 88 2032-C0110P-27B     2032-C0210H-29D       2032-!0210H-27B    2032-C0210W-29D
                                   160A DIN 2032-C0110P-27D   2032-C0300H-29B       2032-!0210H-28D    2032-C0300W-29B
                                   250A DIN 2032-C0110P-28D   2032-C0300H-29D       2032-!0210H-29B    2032-C0300W-29D
                                  200A BS 88 2032-C0180P-27B  2032-C0300H-30B       2032-!0210H-29D    2032-C0300W-30B
                                   250A DIN 2032-C0180P-28D   2032-C0300H-30D       2032-!0300H-29B    2032-C0300W-30D
                                                              2032-C0420H-29B       2032-!0300H-29D    2032-C0420W-29B
                           110                                2032-C0420H-29D       2032-!0300H-30B    2032-C0420W-29D
                                  400A BS 88 2032-C0180P-29B  2032-C0420H-30B       2032-!0300H-30D    2032-C0420W-30B
                                   400A DIN 2032-C0180P-29D   2032-C0420H-30D       2032-!0420H-29B    2032-C0420W-30D
                                  200A BS 88 2032-C0210P-27B  2032*-C0630H-30B      2032-!0420H-29D    2032*-C0630W-30B
                                   250A DIN 2032-C0210P-28D                         2032-!0420H-30B
                                                                                    2032-!0420H-30D
                           200                                                      2032-!0630H-30B
                                  400A BS 88 2032-C0210P-29B
                                   400A DIN 2032-C0210P-29D
                                  400A BS 88 2032-C0300P-29B

                           257 400A DIN 2032-C0300P-29D
                                  630A BS 88 2032-C0300P-30B
                                   630A DIN 2032-C0300P-30D
                                   400A BS88 2032-C0420P-29B
                                   400A DIN 2032-C0420P-29D

                           425
                                  630A BS 88 2032-C0420P-30B
                                   630A DIN 2032-C0420P-30D

                           500 630A BS 88 2032*-C0630P-30B

Power fuses are not included with the disconnect switch. Select power fuses in accordance with applicable local codes.
Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine operator

    to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the "Off" position. See

    next page for instructions on how to order the optional time delay feature. Consult your local Rockwell Automation sales office for other time settings.

12-8
                                                                                                                   Safety Isolation System

                                                                                     ElectroGuard

                                                                      Combination Systems with Fusible Disconnect Switch

Product Selection for Outside North America (see page 12-19 for Ordering Instructions)

         3-Phase Max. kW Rating                                                Catalogue Number
                     (50Hz)

Ampere                                          Fuse Clip                     IP 54 Enclosure  IP 54 Motor Control    IP 65 Enclosure
Rating                                          Rating/                    2032*-C0630H-30D        Centre Type     2032*-C0630W-30D
(AC-3)                                                                     2032*-C0630H-31B                        2032*-C0630W-31B
         230V 400V 500V 600V Type  IP 30 Enclosure                          2032*-C0630H-31D      Enclosure (with   2032*-C0630W-31D
   630                                                                      2032*-C0860H-31B           bussing)     2032*-C0860W-31B
                                                630A DIN 2032*-C0630P-30D
                                                                                                  2032-!0630H30D
          200 355 450 500 800A BS 88 2032*-C0630P-31B
                                                                                                 2032-!0630H-31B
                                               1600A DIN 2032*-C0630P-31D
                                                                                                 2032-!0630H-31D
                                               800A BS 88 2032*-C0860P-31B
                                                                                                 2032-!0860H-31B

860      250 500 560 600                   1250A  2032*-C0860P-32B 2032*-C0860H-32B            2032-!0860H-32B      2032*-C0860W-32B
                                           BS 88

                                           1600A DIN 2032*-C0860P-31D 2032*-C0860H-31D 2032-!0860H-31D 2032*-C0860W-31D

1200     391  710  888 1043                1250A  2032*-C1200P-32B 2032*-C1200H-32B            2032-!1200H-32B 2032*-C1200W-32B
                                           BS 88

                                           1600A DIN 2032*-C1200P-31D 2032*-C1200H-31D 2032-!1200H-31D 2032*-C1200W-31D

To order the Time Delay feature, add the following Cat. String to the end of the Catalogue Number shown in the table:

Factory set 30 second time delay feature:         -1TD

Example: Catalogue Number 2032-C0180P-29B becomes Catalogue Number 2032-C0180P-29B-1TD to include the time delay feature.

* Input Power Feed Catalogue Number Code

The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.

Example: Catalogue Number 2032*-C0630P-31B becomes Catalogue Number 2032T-C0630P-31B for a "Top Feed" input power requirement.

             Input Power Feed              Catalogue Number Code
Top Feed                                                   T
Bottom Feed                                                B

! Bussing Designation

The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below.
Example: Catalogue Number 2032-!0085H-27D becomes Catalogue Number 2032-E0085H-27D for "600A Line Side Incoming Bus and Outgoing Power

Cables" bussing designation.

              Type of Bussing                                        Catalogue Number Code

600A Line Side Incoming Bus and Outgoing Power Cables                       E

1200A Line Side Incoming Bus and Outgoing Power Cables                      D

Line Side Incoming Power Cables and 600A Load Side Outgoing Bus             H

Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus            R

Input Line Voltage Code

The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.

Example: Catalogue Number 2032-C0085W-26B becomes Catalogue Number 2032-C0085WN-26B for a 380V 50Hz Input Line Voltage application.

         Input Line Voltage                220V 50Hz 380-400V 50Hz 400-415V 50Hz 440V 50Hz 500V 50Hz 550V 50Hz

Voltage Code for Catalogue Number          A                      N            G                B               M               C

Product Selection: Remote Lockout Station

                                                                            Catalogue Number

"System Isolated" Light Colour                    IP 30 Enclosure              IP 54 Enclosure     IP 65 Enclosure

Green                                             2030-RLSPG                   2030-RLSHG                       2030-RLSWG

Power fuses are not included with the disconnect switch. Select power fuses in accordance with applicable local codes.
Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine operator

    to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the "Off" position.

    Consult your local Rockwell Automation sales office for other time settings.
Bus Type: Copper with tin plating. Consult factory for other types of bussing.
Safety Isolation Systems rated up through 85A can support a maximum of four (4) Remote Lockout Stations (RLS).

    Systems rated from 110A - 1200A can support a maximum of six (6) RLS. If additional RLS are required, order the optional Expansion Module(s) (see page 12-16).

                                                                                                                                   12-9
Safety Isolation System

ElectroGuard

Combination Systems with Thermal-magnetic Circuit Breaker

Product Selection for North America (see page 12-19 for Ordering Instructions)

        3-Phase Max. Hp Rating                              Catalogue Number
                    (60Hz)

Ampere                          Type 1 General   Type 12    Type 12 Motor    Type 4 Watertight      Type 4X
                                                Dust tight  Control Centre      Painted Steel     Watertight
Rating                          Purpose         Enclosure   Type Enclosure         Enclosure    Stainless Steel
                                                             (with bussing)                        Enclosure
(AC-3) 200V 230V 460V 575V Enclosure

        5   5  5    5 2033-A0023A-39 2033-A0023J-39 2033-!0023J-39 2033-A0023F-39 2033-A0023C-39

23      -   7.5 7.5 7.5 2033-A0023A-40 2033-A0023J-40 2033-!0023J-40 2033-A0023F-40 2033-A0023C-40

        -   -  10   10 2033-A0023A-41 2033-A0023J-41 2033-!0023J-41 2033-A0023F-41 2033-A0023C-41

        -   -  15   15 2033-A0023A-42 2033-A0023J-42 2033-!0023J-42 2033-A0023F-42 2033-A0023C-42

        7.5 -  -    - 2033-A0043A-40 2033-A0043J-40 2033-!0043J-40 2033-A0043F-40 2033-A0043C-40

        10 10 -     - 2033-A0043A-41 2033-A0043J-41 2033-!0043J-41 2033-A0043F-41 2033-A0043C-41

43      - 15 -      - 2033-A0043A-42 2033-A0043J-42 2033-!0043J-42 2033-A0043F-42 2033-A0043C-42

        -   -  20   20 2033-A0043A-43 2033-A0043J-43 2033-!0043J-43 2033-A0043F-43 2033-A0043C-43

        -   -  25   25 2033-A0043A-44 2033-A0043J-44 2033-!0043J-44 2033-A0043F-44 2033-A0043C-44

        -   -  30   30 2033-A0043A-45 2033-A0043J-45 2033-!0043J-45 2033-A0043F-45 2033-A0043C-45

        15  -  -    - 2033-A0085A-42 2033-A0085J-42 2033-!0085J-42 2033-A0085F-42 2033-A0085C-42

        20 20 -     - 2033-A0085A-43 2033-A0085J-43 2033-!0085J-43 2033-A0085F-43 2033-A0085C-43

        25 25 -     - 2033-A0085A-44 2033-A0085J-44 2033-!0085J-44 2033-A0085F-44 2033-A0085C-44

85      - 30 -      - 2033-A0085A-45 2033-A0085J-45 2033-!0085J-45 2033-A0085F-45 2033-A0085C-45

        -   -  40   40 2033-A0085A-46 2033-A0085J-46 2033-!0085J-46 2033-A0085F-46 2033-A0085C-46

        -   -  50   50 2033-A0085A-47 2033-A0085J-47 2033-!0085J-47 2033-A0085F-47 2033-A0085C-47

        -   -  60   60 2033-A0085A-48 2033-A0085J-48 2033-!0085J-48 2033-A0085F-48 2033-A0085C-48

        30  -  -    - 2033-A0110A-45 2033-A0110J-45 2033-!0110J-45 2033-A0110F-45 2033-A0110C-45

110     40 40 -     - 2033-A0110A-46 2033-A0110J-46 2033-!0110J-46 2033-A0110F-46 2033-A0110C-46

        -   -  75   75 2033-A0110A-49 2033-A0110J-49 2033-!0110J-49 2033-A0110F-49 2033-A0110C-49

        -   -  -    100 2033-A0110A-50 2033-A0110J-50 2033-!0110J-50 2033-A0110F-50 2033-A0110C-50

        50 50 -     - 2033-A0180A-47 2033-A0180J-47 2033-!0180J-47 2033-A0180F-47 2033-A0180C-47

        - 60 -      - 2033-A0180A-48 2033-A0180J-48 2033-!0180J-48 2033-A0180F-48 2033-A0180C-48

180     -   -  100  - 2033-A0180A-50 2033-A0180J-50 2033-!0180J-50 2033-A0180F-50 2033-A0180C-50

        -   -  125 125 2033-A0180A-51 2033-A0180J-51 2033-!0180J-51 2033-A0180F-51 2033-A0180C-51

        -   -  150 150 2033-A0180A-52 2033-A0180J-52 2033-!0180J-52 2033-A0180F-52 2033-A0180C-52

        60  -  -    - 2033-A0210A-48 2033-A0210J-48 2033-!0210J-48 2033-A0210F-48 2033-A0210C-48

210     - 75 -      - 2033-A0210A-49 2033-A0210J-49 2033-!0210J-49 2033-A0210F-49 2033-A0210C-49

        -   -  -    175 2033-A0210A-53 2033-A0210J-53 2033-!0210J-53 2033-A0210F-53 2033-A0210C-53

        -   -  -    200 2033-A0210A-54 2033-A0210J-54 2033-!0210J-54 2033-A0210F-54 2033-A0210C-54

        75  -  -    - 2033-A0300A-49 2033-A0300J-49 2033-!0300J-49 2033-A0300F-49 2033-A0300C-49

300     100 100 -   - 2033-A0300A-50 2033-A0300J-50 2033-!0300J-50 2033-A0300F-50 2033-A0300C-50
                    - 2033-A0300A-51 2033-A0300J-51 2033-!0300J-51 2033-A0300F-51 2033-A0300C-51
        - 125 -

Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine
    operator to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the "Off"
    position. See next page for instructions on how to order the optional time delay feature. Consult your local Rockwell Automation sales office for other time settings.

12-10
                                                                                                   Safety Isolation System

                                                                                      ElectroGuard

                                           Combination Systems with Thermal-magnetic Circuit Breaker

Product Selection for North America (see page 12-19 for Ordering Instructions)

          3-Phase Max. Hp Rating                                             Catalogue Number
                      (60Hz)

Ampere    200V  230V  460V  575V            Type 1 General       Type 12     Type 12 Motor    Type 4 Watertight        Type 4X
Rating      -     -   175     -                 Purpose        Dust tight   Control Centre      Painted Steel      Watertight
(AC-3)      -     -   200     -                Enclosure       Enclosure    Type Enclosure         Enclosure     Stainless Steel
             -     -   250                                  2033-A0300J-53    (with bussing)                          Enclosure
   300       -     -         250           2033-A0300A-53   2033-A0300J-54   2033-!0300J-53     2033-A0300F-53   2033-A0300C-53
                   -     -   300           2033-A0300A-54   2033-A0300J-56   2033-!0300J-54     2033-A0300F-54   2033-A0300C-54
   420     125           -                 2033-A0300A-56   2033-A0300J-57   2033-!0300J-56     2033-A0300F-56   2033-A0300C-56
           150   150     -     -           2033-A0300A-57   2033-A0420J-51   2033-!0300J-57     2033-A0300F-57   2033-A0300C-57
   630           175     -     -           2033-A0420A-51   2033-A0420J-52   2033-!0420J-51     2033-A0420F-51   2033-A0420C-51
             -         300     -           2033-A0420A-52   2033-A0420J-53   2033-!0420J-52     2033-A0420F-52   2033-A0420C-52
   860       -     -   350     -           2033-A0420A-53   2033-A0420J-57   2033-!0420J-53     2033-A0420F-53   2033-A0420C-53
             -     -     -   350           2033-A0420A-57   2033-A0420J-58   2033-!0420J-57     2033-A0420F-57   2033-A0420C-57
  1200       -     -     -   400           2033-A0420A-58   2033-A0420J-59   2033-!0420J-58     2033-A0420F-58   2033-A0420C-58
           175     -     -     -           2033-A0420A-59   2033*-A0630J-53  2033-!0420J-59     2033-A0420F-59   2033-A0420C-59
           200   200     -     -           2033*-A0630A-53  2033*-A0630J-54  2033-!0630J-53    2033*-A0630F-53   2033*-A0630C-53
             -   250   400     -           2033*-A0630A-54  2033*-A0630J-56  2033-!0630J-54    2033*-A0630F-54   2033*-A0630C-54
             -     -   450     -           2033*-A0630A-56  2033*-A0630J-59  2033-!0630J-56    2033*-A0630F-56   2033*-A0630C-56
             -     -   500   450           2033*-A0630A-59  2033*-A0630J-60  2033-!0630J-59    2033*-A0630F-59   2033*-A0630C-59
             -     -     -   500           2033*-A0630A-60  2033*-A0630J-61  2033-!0630J-60    2033*-A0630F-60   2033*-A0630C-60
             -     -     -   600           2033*-A0630A-61  2033*-A0630J-62  2033-!0630J-61    2033*-A0630F-61   2033*-A0630C-61
           250     -     -     -           2033*-A0630A-62  2033*-A0860J-56  2033-!0630J-62    2033*-A0630F-62   2033*-A0630C-62
             -   300   600     -           2033*-A0860A-56  2033*-A0860J-57  2033-!0860J-56    2033*-A0860F-56   2033*-A0860C-56
             -     -     -     -           2033*-A0860A-57  2033*-A0860J-62  2033-!0860J-57    2033*-A0860F-57   2033*-A0860C-57
             -     -     -   700           2033*-A0860A-62  2033*-A0860J-63  2033-!0860J-62    2033*-A0860F-62   2033*-A0860C-62
           300     -     -     -           2033*-A0860A-63  2033*-A1200J-57  2033-!0860J-63    2033*-A0860F-63   2033*-A0860C-63
           350   350     -     -           2033*-A1200A-57  2033*-A1200J-58  2033-!1200J-57    2033*-A1200F-57   2033*-A1200C-57
           400   400     -     -           2033*-A1200A-58  2033*-A1200J-59  2033-!1200J-58    2033*-A1200F-58   2033*-A1200C-58
           450   450   900     -           2033*-A1200A-59  2033*-A1200J-60  2033-!1200J-59    2033*-A1200F-59   2033*-A1200C-59
             -     -         900           2033*-A1200A-60  2033*-A1200J-66  2033-!1200J-60    2033*-A1200F-60   2033*-A1200C-60
                                           2033*-A1200A-66                   2033-!1200J-66    2033*-A1200F-66   2033*-A1200C-66

To order the Time Delay feature, add the following Catalogue String to the end of the Catalogue Number shown in the
table:

Factory set 30 second time delay feature:  -1TD

Example: Catalogue Number 2033-A0180A-50 becomes Catalogue Number 2033-A0180A-50-1TD to include the time delay feature.

* Input Power Feed Catalogue Number Code

The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.

Example: Catalogue Number 2033*-A0630A-60 becomes Catalogue Number 2033T-A0630A-60 for a "Top Feed" input power requirement.

          Input Power Feed                 Catalogue Number Code

Top Feed                                   T

Bottom Feed                                B

Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine
    operator to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the "Off"
    position. Consult your local Rockwell Automation sales office for other time settings.

                                                                                                                                             12-11
Safety Isolation System

ElectroGuard

Combination Systems with Thermal-magnetic Circuit Breaker

! Bussing Designation
The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below.
Example: Cat. No. 2033-!0085J-44 becomes Cat. No. 2033-M0085J-44 for "600A Line Side Incoming Bus and Outgoing Power Cables" bussing designation.

                 Type of Bussing                                  Catalogue Number Code

600A Line Side Incoming Bus and Outgoing Power Cables                        M

1200A Line Side Incoming Bus and Outgoing Power Cables                       S

Line Side Incoming Power Cables and 600A Load Side Outgoing Bus              F

Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus             B

Input Line Voltage Code

The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.

Example: Catalogue Number 2033-A0085J-44 becomes Catalogue Number 2033-A0085JB-44 for a 480V 60Hz Input Line Voltage application.

         Input Line Voltage                   208V 60Hz           240V 60Hz              480V 60Hz           600V 60Hz

Voltage Code for Catalogue Number             H                      A                   B                   C

Product Selection: Remote Lockout Station

                                                                  Catalogue Number

"System Isolated" Light Type 1 General Purpose           Type 12 Dust tight        Type 4 Watertight        Type 4X Watertight
                                                               Enclosure        Painted Steel Enclosure  Stainless Steel Enclosure
         Colour                    Enclosure
                                                                                                                2030-RLSCW
White                          2030-RLSAW                2030-RLSJW                   2030-RLSFW

                                                        Combination Systems with Thermal-magnetic Circuit Breaker

Product Selection for Outside of North America (see page 12-19 for Ordering Instructions)

         3-Phase Max. kW Rating                                              Catalogue Number
                     (50Hz)

Ampere   230V    400V   500V       600V    IP 30 Enclosure           IP 54 Enclosure   IP 54 Motor Control      IP 65 Enclosure
Rating    4       4      4          4   2033-C0023P-39K          2033-C0023H-39K     Centre Type Enclosure  2033-C0023W-39K
(AC-3)   5.5     5.5    5.5        5.5  2033-C0023P-40K          2033-C0023H-40K                            2033-C0023W-40K
          7.5     7.5    7.5        7.5  2033-C0023P-41K          2033-C0023H-41K             (w/bussing)    2033-C0023W-41K
    23      -      11     11         11  2033-C0023P-42K          2033-C0023H-42K       2033-!0023H-39K      2033-C0023W-42K
           11       -      -          -  2033-C0043P-42K          2033-C0043H-42K       2033-!0023H-40K      2033-C0043W-42K
    43     13      13     13         13  2033-C0043P-43K          2033-C0043H-43K       2033-!0023H-41K      2033-C0043W-43K
            -      15     15         15  2033-C0043P-44K          2033-C0043H-44K       2033-!0023H-42K      2033-C0043W-44K
    85      -                            2033-C0043P-45K          2033-C0043H-45K       2033-!0043H-42K      2033-C0043W-45K
            -     18.5   18.5      18.5  2033-C0043P-46K          2033-C0043H-46K       2033-!0043H-43K      2033-C0043W-46K
   110     15      22     22         22  2033-C0085P-44K          2033-C0085H-44K       2033-!0043H-44K      2033-C0085W-44K
                    -      -          -  2033-C0085P-45K          2033-C0085H-45K       2033-!0043H-45K      2033-C0085W-45K
          18.5      -      -          -  2033-C0085P-46K          2033-C0085H-46K       2033-!0043H-46K      2033-C0085W-46K
           22       -      -          -  2033-C0085P-47K          2033-C0085H-47K       2033-!0085H-44K      2033-C0085W-47K
           25      25     25         25  2033-C0085P-48K          2033-C0085H-48K       2033-!0085H-45K      2033-C0085W-48K
            -      32     32         32  2033-C0085P-49K          2033-C0085H-49K       2033-!0085H-46K      2033-C0085W-49K
            -      37     37         37  2033-C0085P-50K          2033-C0085H-50K       2033-!0085H-47K      2033-C0085W-50K
            -      45     45         45  2033-C0110P-48K          2033-C0110H-48K       2033-!0085H-48K      2033-C0110W-48K
           32       -      -          -  2033-C0110P-51K          2033-C0110H-51K       2033-!0085H-49K      2033-C0110W-51K
            -      55     55         55  2033-C0110P-52K          2033-C0110H-52K       2033-!0085H-50K      2033-C0110W-52K
            -       -     63         63                                                 2033-!0110H-48K
                                                                                        2033-!0110H-51K
                                                                                        2033-!0110H-52K

Bus Type: Copper with tin plating. Consult factory for other types of bussing.
Safety Isolation Systems rated up through 85A can support a maximum of four (4) Remote Lockout Stations (RLS).

    Systems rated from 110A - 1200A can support a maximum of six (6) RLS. If additional RLS are required, order the optional Expansion Module(s) (see page 12-16).
Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine

    operator to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the "Off"

    position. See page 12-14 for instructions on how to order the optional time delay feature. Consult your local Rockwell Automation sales office for other time settings.

12-12
                                                                                         Safety Isolation System

                                                                            ElectroGuard

                                 Combination Systems with Thermal-magnetic Circuit Breaker

Product Selection for Outside of North America (see page 12-19 for Ordering Instructions)

         3-Phase Max. kW Rating                     Catalogue Number
                     (50Hz)

Ampere   230V  400V  500V  600V    IP 30 Enclosure  IP 54 Enclosure   IP 54 Motor Control      IP 65 Enclosure
Rating     -     -     -    75  2033-C0110P-53K                     Centre Type Enclosure  2033-C0110W-53K
(AC-3)     -     -     -   100  2033-C0110P-55K                                            2033-C0110W-55K
           37     -     -     -  2033-C0180P-49K                             (w/bussing)    2033-C0180W-49K
   110     45     -     -     -  2033-C0180P-50K                                            2033-C0180W-50K
           55     -     -     -  2033-C0180P-51K    2033-C0110H-53K 2033-!0110H-53K         2033-C0180W-51K
   180      -    63     -     -  2033-C0180P-52K                                            2033-C0180W-52K
            -    75    75     -  2033-C0180P-53K    2033-C0110H-55K 2033-!0110H-55K         2033-C0180W-53K
   210      -    90    90     -  2033-C0180P-54K                                            2033-C0180W-54K
            -     -         110  2033-C0180P-56K    2033-C0180H-49K 2033-!0180H-49K         2033-C0180W-56K
   300      -     -   110   132  2033-C0180P-57K                                            2033-C0180W-57K
            -     -     -   150  2033-C0180P-58K    2033-C0180H-50K 2033-!0180H-50K         2033-C0180W-58K
   420      -     -     -   160  2033-C0180P-59K                                            2033-C0180W-59K
           63     -     -     -  2033-C0210P-52K    2033-C0180H-51K 2033-!0180H-51K         2033-C0210W-52K
            -           -     -  2033-C0210P-56K                                            2033-C0210W-56K
            -   110     -     -  2033-C0210P-57K    2033-C0180H-52K 2033-!0180H-52K         2033-C0210W-57K
            -     -           -  2033-C0210P-58K                                            2033-C0210W-58K
            -     -   132   185  2033-C0210P-60K    2033-C0180H-53K 2033-!0180H-53K         2033-C0210W-60K
            -     -   150   200  2033-C0210P-61K                                            2033-C0210W-61K
           75     -           -  2033-C0300P-53K    2033-C0180H-54K 2033-!0180H-54K         2033-C0300W-53K
           90     -     -     -  2033-C0300P-54K                                            2033-C0300W-54K
            -     -     -     -  2033-C0300P-57K    2033-C0180H-56K 2033-!0180H-56K         2033-C0300W-57K
            -           -     -  2033-C0300P-58K                                            2033-C0300W-58K
            -   132     -     -  2033-C0300P-59K    2033-C0180H-57K 2033-!0180H-57K         2033-C0300W-59K
            -   150     -     -  2033-C0300P-60K                                            2033-C0300W-60K
            -   160     -     -  2033-C0300P-61K    2033-C0180H-58K 2033-!0180H-58K         2033-C0300W-61K
            -         160   220  2033-C0300P-62K                                            2033-C0300W-62K
            -     -   185   250  2033-C0300P-63K    2033-C0180H-59K 2033-!0180H-59K         2033-C0300W-63K
            -     -   200   300  2033-C0300P-64K                                            2033-C0300W-64K
                  -     -     -  2033-C0420P-56K    2033-C0210H-52K 2033-!0210H-52K         2033-C0420W-56K
          110     -     -     -  2033-C0420P-57K                                            2033-C0420W-57K
          132     -     -     -  2033-C0420P-60K    2033-C0210H-56K 2033-!0210H-56K         2033-C0420W-60K
                  -     -
            -     -     -                           2033-C0210H-57K 2033-!0210H-57K
                185     -
                                                    2033-C0210H-58K 2033-!0210H-58K

                                                    2033-C0210H-60K 2033-!0210H-60K

                                                    2033-C0210H-61K 2033-!0210H-61K

                                                    2033-C0300H-53K 2033-!0300H-53K

                                                    2033-C0300H-54K 2033-!0300H-54K

                                                    2033-C0300H-57K 2033-!0300H-57K

                                                    2033-C0300H-58K 2033-!0300H-58K

                                                    2033-C0300H-59K 2033-!0300H-59K

                                                    2033-C0300H-60K 2033-!0300H-60K

                                                    2033-C0300H-61K 2033-!0300H-61K

                                                    2033-C0300H-62K 2033-!0300H-62K

                                                    2033-C0300H-63K 2033-!0300H-63K

                                                    2033-C0300H-64K 2033-!0300H-64K

                                                    2033-C0420H-56K 2033-!0420H-56K

                                                    2033-C0420H-57K 2033-!0420H-57K

                                                    2033-C0420H-60K 2033-!0420H-60K

Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine
    operator to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the "Off"
    position. See next page for instructions on how to order the optional time delay feature. Consult your local Rockwell Automation sales office for other time settings.

                                                                                            12-13
Safety Isolation System

ElectroGuard

Combination Systems with Thermal-magnetic Circuit Breaker

Product Selection for Outside of North America (see page 12-19 for Ordering Instructions)

          3-Phase Max. kW Rating                                  Catalogue Number
                      (50Hz)

Ampere    230V 400V  500V 600V                IP 30 Enclosure     IP 54 Enclosure   IP 54 Motor Control       IP 65 Enclosure
Rating                                    2033-C0420P-61K     2033-C0420H-61K     Centre Type Enclosure  2033-C0420W-61K
(AC-3)      - 200   -      -              2033-C0420P-62K     2033-C0420H-62K                            2033-C0420W-62K
                                           2033-C0420P-63K     2033-C0420H-63K             (w/bussing)    2033-C0420W-63K
   420       - 220   220 -                 2033-C0420P-64K     2033-C0420H-64K       2033-!0420H-61K      2033-C0420W-64K
                                           2033-C0420P-65K     2033-C0420H-65K       2033-!0420H-62K      2033-C0420W-65K
   630       -  -    250 -                 2033-C0420P-66K     2033-C0420H-66K       2033-!0420H-63K      2033-C0420W-66K
                                           2033-C0420P-67K     2033-C0420H-67K       2033-!0420H-64K      2033-C0420W-67K
   860       -  -    300 -                 2033*-C0630P-58K    2033*-C0630H-58K      2033-!0420H-65K      2033*-C0630W-58K
                                           2033*-C0630P-59K    2033*-C0630H-59K      2033-!0420H-66K      2033*-C0630W-59K
  1200       -  -    - 355                 2033*-C0630P-60K    2033*-C0630H-60K      2033-!0420H-67K      2033*-C0630W-60K
                                           2033*-C0630P-61K    2033*-C0630H-61K      2033-!0630H-58K      2033*-C0630W-61K
             -  -    - 390                 2033*-C0630P-63K    2033*-C0630H-63K      2033-!0630H-59K      2033*-C0630W-63K
                                           2033*-C0630P-64K    2033*-C0630H-64K      2033-!0630H-60K      2033*-C0630W-64K
             -  -    - 425                 2033*-C0630P-65K    2033*-C0630H-65K      2033-!0630H-61K      2033*-C0630W-65K
                                           2033*-C0630P-66K    2033*-C0630H-66K      2033-!0630H-63K      2033*-C0630W-66K
             150 -   -      -              2033*-C0630P-68K    2033*-C0630H-68K      2033-!0630H-64K      2033*-C0630W-68K
                                           2033*-C0630P-69K    2033*-C0630H-69K      2033-!0630H-65K      2033*-C0630W-69K
             160 -   -      -              2033*-C0860P-63K    2033*-C0860H-63K      2033-!0630H-66K      2033*-C0860W-63K
                                           2033*-C0860P-68K    2033*-C0860H-68K      2033-!0630H-68K      2033*-C0860W-68K
             185 -   -      -              2033*-C0860P-69K    2033*-C0860H-69K      2033-!0630H-69K      2033*-C0860W-69K
                                           2033*-C0860P-70K    2033*-C0860H-70K      2033-!0860H-63K      2033*-C0860W-70K
             200 -   -      -              2033*-C0860P-71K    2033*-C0860H-71K      2033-!0860H-68K      2033*-C0860W-71K
                                           2033*-C1200P-64K    2033*-C1200H-64K      2033-!0860H-69K      2033*-C1200W-64K
             - 250   -      -              2033*-C1200P-66K    2033*-C1200H-66K      2033-!0860H-70K      2033*-C1200W-66K
                                           2033*-C1200P-71K    2033*-C1200H-71K      2033-!0860H-71K      2033*-C1200W-71K
             - 300   -      -              2033*-C1200P-72K    2033*-C1200H-72K      2033-!1200H-64K      2033*-C1200W-72K
                                           2033*-C1200P-73K    2033*-C1200H-73K      2033-!1200H-66K      2033*-C1200W-73K
             - 355   355 -                 2033*-C1200P-74K    2033*-C1200H-74K      2033-!1200H-71K      2033*-C1200W-74K
                                           2033*-C1200P-75K    2033*-C1200H-75K      2033-!1200H-72K      2033*-C1200W-75K
             -  -    390 -                 2033*-C1200P-76K    2033*-C1200H-76K      2033-!1200H-73K      2033*-C1200W-76K
                                                                                     2033-!1200H-74K
             -  -    450 450                                                         2033-!1200H-75K
                                                                                     2033-!1200H-76K
             -  -    - 500

             250 -   -      -

             - 450   -      -

             - 500   500 -

             -  -    560 560

             -  -    - 600

             300 -   -      -

             390 -   -      -

             - 600   600 -

             - 710   710 710

             -  -    750 750

             -  -    850 850

             -  -    888 888

             -  -    - 1043

To order the Time Delay feature, add the following Catalogue String to the end of the Cat. No. shown in the table:

Factory set 30 second time delay feature:  -1TD

Example: Catalogue Number 2033-C0180P-54K becomes Catalogue Number 2033-C0180P-54K-1TD to include the time delay feature.

* Input Power Feed Catalogue Number Code

The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.

Example: Catalogue Number 2033*-C0630P-58K becomes Catalogue Number 2033T-C0630P-58K for a "Top Feed" input power requirement.

          Input Power Feed                 Catalogue Number Code

Top Feed                                   T

Bottom Feed                                B

Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine
    operator to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the "Off"
    position. Consult your local Rockwell Automation sales office for other time settings.

12-14
                                                                                                            Safety Isolation System

                                                                                       ElectroGuard

                        Combination Systems with Thermal-magnetic Circuit Breaker/Optional Features

Product Selection for Outside of North America (see page 12-19 for Ordering Instructions)

! Bussing Designation

The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below.
Example: Catalogue Number 2033-!0085H-44K becomes Catalogue Number 2033-E0085H-44K for "600A Line Side Incoming Bus and Outgoing Power

Cables" bussing designation.

                    Type of Bussing                                           Catalogue Number Code

600A Line Side Incoming Bus and Outgoing Power Cables                                        E

1200A Line Side Incoming Bus and Outgoing Power Cables                                       D

Line Side Incoming Power Cables and 600A Load Side Outgoing Bus                              H

Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus                             R

Input Line Voltage Code

The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.

Example: Catalogue Number 2033-C0085W-48K becomes Catalogue Number 2033-C0085WN-48K for a 380V 50Hz Input Line Voltage application.

Input Line Voltage                       220V 50Hz 380-400V 50Hz 400-415V 50Hz 440V 50Hz 500V 50Hz 550V 50Hz

Voltage Code for Catalogue Number        A              N                                       G               B     M  C

Product Selection: Remote Lockout Station

   "System Isolated" Light Colour               IP 30 Enclosure                              Catalogue Number         IP 65 Enclosure
Green                                             2030-RLSPG                                   IP 54 Enclosure         2030-RLSWG
                                                                                                 2030-RLSHG

Optional Features

Pneumatic Isolation Module (Must be ordered with Safety Isolation System):

The Safety Isolation System is available with an optional means of isolating the pneumatic energy source
for the machine or process. If the machine operator/maintenance personnel initiates isolation of the
electrical energy by operating one of the Remote Lockout Stations, a safety valve is simultaneously
actuated to bleed pressure from the air line between the valve and the machine. When the air pressure has
fallen to a predetermined level, the unit will allow the light on the Remote Lockout Station to illuminate,
if electrical isolation has also been achieved.

To order the Pneumatic Isolation option:

Step 1: Add the following Catalogue String to the Safety Isolation System Catalogue Number:

To indicate that the Safety Isolation             -1PN
System should be supplied as "Pneumatic
Ready."

e.g. 2031-A0085JB-1PN to indicate an 85A Safety Isolation System that is to be "Pneumatic Ready."

Step 2: Order suitably enclosed Pneumatic Isolation Module as separate item:

For North America:

                                                                              Catalogue Number

Pressure    Valve Port           Type 1 General         Type 12 Dust tight                         Type 4 Watertight  Type 4X Watertight
  Range         Size           Purpose Enclosure              Enclosure
                                                                                                   Painted Steel Enclosure Stainless Steel Enclosure
30-120 psi       1in               2030-PA1201
                                                                 2030-PJ1201                       2030-PF1201           2030-PC1201
                3/4in              2030-PA1203
                                                                 2030-PJ1203                       2030-PF1203           2030-PC1203

For Outside of North America:

                                                                                                   Catalogue Number

Pressure Range                 Valve Port Size          IP 30 Enclosure                            IP 54 Enclosure       IP 65 Enclosure

2-7 bar                                   1in           2030-PP0071                                2030-PH0071           2030-PW0071
                                         3/4in          2030-PP0073                                2030-PH0073           2030-PW0073

Bus Type: Copper with tin plating. Consult factory for other types of bussing.
Safety Isolation Systems rated up through 85A can support a maximum of four (4) Remote Lockout Stations (RLS).

    Systems rated from 110A - 1200A can support a maximum of six (6) RLS. If additional RLS are required, order the optional Expansion Module(s) (see page 12-16).

                                                                                                                         12-15
Safety Isolation System                                                    Note: The time delay feature affects all input devices wired to the
                                                                           Expansion Module.
ElectroGuard
                                                                           For Expansion Module(s) Factory Installed:
Optional Features (continued)                                              Add One of the Following Catalogue Number Strings to
                                                                           the Safety Isolation System Catalogue Number:
Expansion Module (Can be ordered separately):
                                                                                                  Number of Ports
                                          For applications requiring more
                                          than the maximum allowable       Number of              per Expansion Catalogue Number
                                          Remote Lockout Stations, or
                                          total wire lengths longer than   Expansion Modules      Module           String
                                          those permitted with the
                                          Remote Lockout Stations.         One (available on              4           -1EUF
                                          Expansion Modules are            Bulletin 2031, 2032,   4 w/time delay   -1EUFTDA
                                          available in 4 or 10 port        or 2033, 110A
                                          configurations. Each Expansion   1200A Systems only)            10          -1EUT
Module is wired to a port on the Control Module, and takes the                                    10 w/time delay  -1EUTTDA
connection port that would normally accommodate a Remote
Lockout Station (see page 12-18 to determine if an Expansion               Two (available on              4           -2EUF
Module is required due to wire length considerations).                     630A 1200A           4 w/time delay   -2EUFTDA
                                                                           Bulletin 2032 or 2033
The 23A through 85A systems will accommodate connection of a               Systems only)                  10          -2EUT
maximum of 4 Expansion Modules, and the 110A through 1200A                                        10 w/time delay  -2EUTTDA
systems will accommodate connection of a maximum of 6
Expansion Modules.                                                          e.g. Catalogue Number 2032T-A0630JB-30L becomes Catalogue Number
                                                                               2032T-A0630JB-30L-2EUT to indicate a 630A Safety Isolation System that
Certain ampere size Safety Isolation System Power Panels can                   includes 2 internally installed 10 port Expansion Modules without the time delay
accommodate either 1 or 2 Expansion Modules installed internally.              feature.
In all other instances the Expansion Module(s) must be located
external to the Safety Isolation System in a suitably rated enclosure.

Ampere Size of Safety Internal Provisions to Accommodate                   Open Type Expansion Module for Field Addition

Isolation System      Expansion Modules                                                                            Open Type

         23A - 85A               None                                               Description              Catalogue Number

        110A - 420A   Provisions to accept one (1) Expansion               4 port                                  2030-EUNF
                      Module (Bulletins 2031, 2032 or 2033)
                                                                           4 port w/ time delay              2030-EUNF-1TDA
                           Provisions to accept up to two (2)
                      Expansion Modules in Bulletin 2032 or 2033           10 port                                 2030-EUNT
                      combination systems, or one (1) Expansion
630A - 1200A                                                               10 port w/time delay              2030-EUNT-1TDA
                       Module in Bulletin 2031 non combination
                                           systems.                         Requires user supplied enclosure if not installed in the Safety Isolation System
                                                                               Power Panel.

Expansion Modules may be ordered with an adjustable time delay              To order the Status Communication to a remote PLC option installed in an
feature (1-30 seconds) in order to allow time for the machine                  enclosed Expansion Module, add one of the following Catalogue Strings to the
operator to shut-down drives or other equipment that requires a                Expansion Module Catalogue Number:
controlled stop after a Remote Lockout Station has been switched to
the "Off " position. Consult your Rockwell Automation sales office         Communication          Number of I/O         Catalogue
for other time settings.                                                        Platform                Points     Number String

Enclosed Expansion Modules are available with optional "Flex"              Remote I/O             16 points        -1COM
modules to provide status communication to a remote PLC.
Communication can be via DeviceNet or Remote I/O.                          DeviceNet              16 points        -1DNET

Note: The status communication option allows a remote PLC to receive        e.g. Catalogue Number 2030-EUJF becomes Catalogue Number 2030-EUJF-
status signals from the Expansion Module. The Expansion Module does            1COM to indicate a Type 12 enclosed, 4-port expansion module, with 16 points
not accept input signals from DeviceNet or Remote I/O.                         of remote I/O.

To order the optional enclosed Expansion Module for field addition for North America:

                                                                           Catalogue Number

Description           Type 1 Enclosure Type12 Enclosure Type 4 Painted Enclosure Type 4X Stainless Steel Enclosure

4 port                2030-EUAF        2030-EUJF                           2030-EUFF                               2030-EUCF

4 port w/ time delay 2030-EUAF-1TDA 2030-EUJF-1TDA                         2030-EUFF-1TDA                 2030-EUCF-1TDA

10 port               2030-EUAT        2030-EUJT                           2030-EUFT                               2030-EUCT

10 port w/time delay 2030-EUAT-1TDA 2030-EUJT-1TDA                         2030-EUFT-1TDA                    2030-EUCT-1TDA

To order the optional enclosed Expansion Module for field addition for outside of North America:

                                                                           Catalogue Number

         Description             IP30 Enclosure                            IP54 Enclosure                          IP65 Enclosure

4 port                           2030-EUPF                                          2030-EUHF                      2030-EUWF

4 port w/ time delay             2030-EUPF-1TDA                            2030-EUHF-1TDA                    2030-EUWF-1TDA

10 port                          2030-EUPT                                          2030-EUHT                      2030-EUWT

10 port w/time delay             2030-EUPT-1TDA                            2030-EUHT-1TDA                    2030-EUWT-1TDA

12-16
                                                                                                Safety Isolation System

                                                                                                ElectroGuard

                                                                                       Optional Features (continued)

Status Communication to a remote PLC (Should be ordered with Safety Isolation System)
This option provides Remote I/O via "Flex" modules. Communication can be via:

The DeviceNet communication platform, or
The Remote I/O communication platform.

Note: The status communication option allows a remote PLC to receive status signals
from the ElectroGuard Safety Isolation System. The ElectroGuard does not accept input
signals through these communication platforms.

Status communication capabilities:

Overall system status,
Status of each Remote Lockout Station,
Status of the Pneumatic Isolation Module (if used),
Status of other optional Safety Input devices.

Note: Each communication module provides sixteen (16) data points. In determining which Catalogue Number String to specify from the table below,
please keep the following in mind:

Overall system status information requires one (1) data point.
The Pneumatic Isolation Module (if used) requires one (1) data point.
Each Remote Lockout Station used in the application requires one (1) data point.
Each optional Rockwell Automation Safety Input device (i.e. Safety Mat, Light Curtain, E-Stop Station, Proximity Switch, Photo Switch)

   requires one (1) data point.

To order the Status Communication to a remote PLC option, add one of the following Catalogue Strings to the Safety
Isolation System Catalogue Number:

             Communication Platform                    Number of I/O points            Catalogue Number String
Remote I/O                                                     16 points                            -1COM
                                                                32 points                            -2COM
DeviceNet                                                      48 points                           -3COM"
" Maximum available for units from 23A through 85A.             64 points                            -4COM!
! Only available on units from 110A through 1200A.              16 points                            -1DNET
                                                                32 points                            -2DNET
                                                                48 points
                                                                64 points                           -3DNET"
                                                                                                    -4DNET!

e.g. Catalogue Number 2031-A0085JB becomes Catalogue Number 2031-A0085JB-1COM to indicate an 85A Safety Isolation System that includes 16 points of
    Remote I/O for status communication to a remote PLC.

Cover Mounted Metering (Must be ordered with Safety Isolation System):

Cover mounted ammeters and/or voltmeters are available as factory installed options in order to provide visual indication of line side system
current and/or voltage.

To order metering, add one or more of the following Catalogue Strings to the Safety Isolation System Catalogue
Number:

       Type of Metering Required                     Catalogue Number String
Single-phase Ammeter                                                 -1AM
Three-phase Ammeter                                                  -3AM
Single-phase Voltmeter                                               -1VM
Three-phase Voltmeter                                                -3VM

e.g. Catalogue Number 2031-A0085JB becomes Catalogue Number 2031-A0085JB-1AM to indicate an 85A Safety Isolation System that includes a cover mounted
    single-phase Ammeter.

                                                                                       12-17
Safety Isolation System

ElectroGuard

Typical Wiring Diagram/Wire Length Considerations

Typical Wiring Diagram                                                   Total Wire Length for Expansion Modules

        Safety Isolation System                                              For North America                For Outside North America
        with Optional Fusible GC
        Disconnecting Means                                                                      Max. Total                           Max. Total
                                                                         Wire Gauge Wire Length               Wire Gauge Wire Length
                                                                                                             18 Gauge Metric 12,200 meters
                                                                         14AWG             40,000 feet
                                                                                                             14 Gauge Metric 7,000 meters
                                                                         16AWG             23,000 feet

                                                                         18AWG             11,700 feet

L1          1IC 2IC                          T1                          Sample Calculation: An application for a 630A Safety Isolation
                                                                         System will require 8 Remote Lockout Stations (RLS):

L2                                           T2 To Motor     To          The wire length from RLS # 1 to the Control Module (in the
L3                                                 Starters  Loads       ElectroGuard Power Panel) will be 50ft.
                                                                         The wire length from RLS # 2 to the Control Module will be 200ft.
                                             T3                          The wire length from RLS # 3 to the Control Module will be 100ft.
                                                                         The wire length from RLS # 4 to the Control Module will be 300ft.
Designates  Remote                                                       The wire length from RLS # 5 to the Control Module will be 500ft.
field       Lockout                                                      The wire length from RLS # 6 to the Control Module will be 1000ft.
connection  Station(s)                                                   The wire length from RLS # 7 to the Control Module will be 850ft.
points                                                                   The wire length from RLS # 8 to the Control Module will be 750ft.

Wire Length Considerations                                               14AWG wire will be used to connect the RLS to the Control Module
                                                                         (see illustration below).

            ATTENTION: It is important not to                                         152m                    304m        259m     228m
            exceed the maximum wire length values                                     (500ft)                (1000ft)     (850ft)  (750ft)
            shown in this section. If the maximum values
            are exceeded, this may result in an unreliable               RLS RLS
            signal to the Safety Isolation System.
            Consider using an Expansion Module if wire                   #5       #4                                               RLS
            lengths greater than those shown for the
            Remote Lockout Stations are needed.                                                                                    #8

                                                                                                             Expansion
                                                                                                              Module

Each Remote Lockout Station is connected to the Control Module                91m (300ft)                                 RLS
in the Power Panel of the Safety Isolation System. The total length                                                       #7
of the wire used to connect the Remote Lockout Stations to the                30m (100ft)
Control Module should not exceed the maximum values shown in                                                                    RLS
the following tables.                                                                                                            #6

Calculate the total wire length as follows:                                  RLS                             Control
                                                                             #3                              Module

1. Determine the distance in feet or meters from each Remote             61m (200ft)           RLS
   Lockout Station to the Control Module (located inside the Safety                            #1
   Isolation System Power Panel).
                                                                         RLS                                 Power Panel
2. Sum the distances for all of the Remote Lockout Stations.             #2
3. Double this value.
4. Compare this doubled value with the maximum values for total                                              15m (50ft)

   wire length shown in the table below:                                 Analysis: The Control Module furnished with the 630A Safety
                                                                         Isolation System is capable of supporting a maximum of six (6) RLS.
Total Wire Length for Remote Lockout Stations                            Since this installation will require eight (8) RLS, an optional 4 port
                                                                         Expansion Module will also be used. The Expansion Module will be
    For North America               For Outside of North America         wired to the Control Module and will take the place of one of the
                                                                         original six RLS. We will, therefore, plan to wire five (5) of the RLS
                        Max. Total                           Max. Total  directly to the Control Module and three (3) of the RLS to the
Wire Gauge Wire Length               Wire Gauge Wire Length              Expansion Module. Since the Expansion Module allows greater wire
                                                                         lengths than the Control Module, we will plan to wire the RLS to be
    14AWG   4,600 feet              18 Gauge Metric 1,400 meters         installed furthest away from the Power Panel to the Expansion
                                                                         Module.
    16AWG   2,600 feet              14 Gauge Metric 800 meters

    18AWG   1,300 feet

If the application requires a total wire length greater than those       For RLS # 1: wire length = 50ft x 2 = 100ft
shown in the table, one or more Expansion Modules should be used.        For RLS # 2: wire length = 200ft x 2 = 400ft
The maximum wire length for the Expansion Modules is shown in            For RLS # 3: wire length = 100ft x 2 = 200ft
the following table:                                                     For RLS # 4: wire length = 300ft x 2 = 600ft
                                                                         For RLS # 5: wire length = 500ft x 2 = 1000ft

12-18
                                                                                                                   Safety Isolation System

                                                                                                           ElectroGuard

                                                                           Wire Length Considerations/Ordering Instructions

The total wire length for the 5 RLS to be wired to the Control                 b. Sum the full-load currents of all the motor loads to be
Module will be: 100ft + 400ft + 200ft + 600ft + 1,000ft = 2,300ft                   connected to the Safety Isolation System. To this value add
                                                                                    the current values of all resistive loads to be connected to
Per the table entitled Total Wire Length for Remote Lockout Stations on             the Safety Isolation System. This value is the "combined
page 12-18, the maximum allowable wire length for 14AWG wire is                     load full-load current."
4,600ft for the RLS to be wired to the Control Module. This portion
of the installation will be within the maximum wire length permitted.          c. Find the horsepower or kilowatt rating of a single motor with
                                                                                    a full-load current value greater than or equal to the
Next, we need to check the wire length calculation for the RLS to be                "combined load full-load current" value determined in Step
wired to the Expansion Module.                                                      "b".

For RLS # 6: wire length = 1000ft x 2 = 200ft                                  d. Select the Safety Isolation System that meets or exceeds this
For RLS # 7: wire length = 850ft x 2 = 1700ft                                       horsepower or kilowatt rating at the required voltage and
For RLS # 8: wire length = 750ft x 2 = 1500ft                                       frequency.

The total wire length for the 3 RLS to be wired to the Expansion               e. Sum the locked-rotor currents of all the motor loads to be
Module will be: 2000ft + 1700ft + 1500ft = 5,200ft                                  connected to the Safety Isolation System. To this value add
                                                                                    the current values of all resistive loads to be connected to
Per the table entitled Total Wire Length for Expansion Modules on page              the Safety Isolation System. This value is the "combined
12-18, the maximum allowable wire length for 14AWG wire is                          load locked-rotor current".
40,000ft for the RLS to be wired to the Expansion Module. This
portion of the installation will also be within the maximum wire               f. Find the horsepower or kilowatt rating of a single motor with
length permitted.                                                                   a locked-rotor current value greater than or equal to the
                                                                                    "combined load locked-rotor current" value determined in
Ordering Instructions                                                               Step "e".
1. Determine the Catalogue Number of the Safety Isolation System
                                                                               g. Select the Safety Isolation System that meets or exceeds this
   based on the rating of the load(s) to which it will be connected as              horsepower or kilowatt rating at the required voltage and
   follows:                                                                         frequency.

   If the Safety Isolation System is connected to a single motor load,         h. Compare the ratings of the Safety Isolation Systems selected
   the horsepower or kilowatt rating of the system should be                        in Steps "d" and "g". Select the larger of the two systems for
   determined as follows:                                                           your application.
    a. Select the Safety Isolation System that meets or exceeds the
                                                                           2. Determine how many Remote Lockout Stations are required for
         horsepower or kilowatt rating of the load at the required            the application.
         voltage and frequency.
                                                                           3. Determine how many Expansion Modules (if any) are required
   If the Safety Isolation System is connected to two or more                 for the application.
   motors or one or more motors in combination with other loads,
   the horsepower or kilowatt rating of the system should be               4. Pick suitable enclosure type(s) for the Safety Isolation System
   determined as follows:                                                     Power Panel, Remote Lockout Stations and enclosed modules
    a. Identify the types of loads (i.e. motor, resistive) and the values     (e.g., Expansion Modules, Pneumatic Isolation Module).

         of the currents of each of the loads (i.e. steady-state current   5. Determine what, if any, factory installed options are required for
         for resistive loads, full-load and locked-rotor currents for         the application (e.g. Pneumatic Isolation, Status Communication
         motor loads) to be connected to the Safety Isolation System.         to remote PLC, metering).

                                                                           12-19
Safety Isolation System

Notes

12-20
This datasheet has been downloaded from:
             www.EEworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company

2033-C0085W-46K器件购买:

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved