datasheet

电子工程世界电子工程世界电子工程世界

型号

产品描述

搜索

200-6315-9UN-1900

器件型号:200-6315-9UN-1900
器件类别:连接器    IC与器件插座   
厂商名称:3M
厂商官网:http://3M.com/esd
下载文档

器件描述

IC & Component Sockets 15X15 SKT KIT WITHOUT CONTACTS

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
3M
产品种类:
Product Category:
IC & Component Sockets
RoHS:In Transition
产品:
Product:
Test & Burn-In Sockets
位置数量:
Number of Positions:
225 Position
排数:
Number of Rows:
15 Row
类型:
Type:
PGA Sockets
节距:
Pitch:
2.54 mm
端接类型:
Termination Style:
Solder
主体材料:
Contact Plating:
-
Row Spacing:2.54 mm
外壳材料:
Housing Material:
Polyethersulfone (PES)
商标:
Brand:
3M Electronic Solutions Division
Flammability Rating:UL 94 V-0
安装风格:
Mounting Style:
PCB
最大工作温度:
Maximum Operating Temperature:
+ 150 C
最小工作温度:
Minimum Operating Temperature:
- 55 C
工厂包装数量:
Factory Pack Quantity:
10
零件号别名:
Part # Aliases:
05113869652 JE150901294
单位重量:
Unit Weight:
1 lb

200-6315-9UN-1900器件文档内容

Test & Burn-In                                PGA           Kit  Sockets

Pin Grid Arrays

                                                                 •  Available in 10 x 10 matrix through 25 x 25

                                                                    matrix

                                                                 •  Used when only a few test sockets are needed

                                                                 •  Provides individual components ready for

                                                                    assembly

                                                                 •  Open pattern top plate; load only those contacts

                                                                    needed for your specific device pin pattern

                                                                                                                     TS-0675-09

                                                                 Date Issued: June 20, 2001                          Sheet 1 of  2

10

Physical

                        Insulation

                        Material:      Polyethersyfone (PES)

                        Flammability:  UL 94V-0

                        Color:         Black

                        Marking:       3M Logo & Part Number Identifier

                        Cam Handle

                        Material:      Stainless Steel

                        Contact

                        Material:      Beryllium Copper

            Plating Options:           30 m" (0.76 mm) Gold over 50 m" (1.3 mm) Nickel

Electrical

            Current Rating:            1 Amp

    Insulation Resistance:             > 1 ¥ 1012 W at 500 Vdc

    Withstanding Voltage:              1000 Vrms at Sea Level

Environmental

Temperature Rating Operating:          - 55°∞C to + 150∞°C

Mechanical

                                       A: When used as a test socket at room temperature 24∞°C the socket will last

                                       25,000 actuations.

                                       B: Based on field experience, under normal burn-in conditions up to a

                                       maximum of 150∞°C, the socket should last an average of four years.

3M Electronic Handling and Protection Division

6801 River Place Blvd.                                          For technical, sales or ordering information call 800-328-0411

Austin, TX 78726-9000                                                       or visit our website:  http://www.3M.com/ehpd
Test & Burn-In PGA Kit Socket

Pin Grid Arrays

                                                                                                                       Assembly Instructions

                                                                                                          1.  Load hole plugs into top plate by

                                                         4X Phillips Pan-Hd                                   pressing fitting into place.

                                                         #0-80 x 5/16 Long                                    Remove from tie bar by cutting

                                                         Assy Screw                                           with commercially available 6 1/2"

        1  10X Hole Plugs                                                                                     flush diagonal cutter pliers.

                                                                                                          2.  Place cam plate into recessed

                                                                                                              area of base plate, load

                                                                                                              contacts in desired locations,

                                                                                                              being careful that the bent leaf

                                                                                                              of the contact is loaded in

                                                                                                              correct position ( away from

                                                                                                              cam handle. )

                                                                                                          3.  Insert cam handle into position

                                                                                                              in the base plate.

                                                                                                          4.  Now make a final check that all

                                                                                                              contacts are in desired location

           Top Plate                                                                                          and that all are fairly even at the

                                                                                                              top. Also check cam to make

                                                                                                              sure it is still in position. Now

                                                                                                              take the top plate and place into

                                                                                                              position and start to lower over

        Contact                                                                                               contacts. Start at the rear of the

        ( Order Separately )                                                                                  socket and rotate downward

                                                                                                              toward the front and then snap

                                                                                                              locating bosses into place.

                                                                                                              Several very slight back and

           Cam Plate                                                                                          forth motions may be necessary

                                                                                                              in order to get contacts to snap

                                                                                                              into place. Care should be taken

                                                                                                              that too much downward

                                                                                                              pressure isn't applied which

                                                                                                              could bend or damage the

                                                                                                              contacts. Insert screws and

                                                                                                              tighten.

                                                                                                          5.  Now make an operation check

                                                                                                              by rotating handle 90∞. Make a

                                                                      Cam Handle                              visual check of movement and

                                                                                                              closure of all contacts. Rotate

                 Base Plate                                                                                   handle and check the freedom

                                                                                                              of movement of cam plate and

                                                                                                Standard      that the moving leaf of the

                                                                                                Handle        contact clears the entry hole. A

                                                                                                              continuity check can be made

                                                                                                              before final soldering by placing

                                                                                                              device in socket, then closing

Notes:                                                                                                        and making check. Soldering

1  Contact and extra Hole Plugs are ordered separately.                                                       should be done with socket in

2  See Test & Burn-In PGA socket section on page 29 for  dimensional information on  assembled  sockets.      the open position.

Ordering Information

                                                         Part Number  Matrix Size                         Description

                              200-6310-9UN-1900                                      10 x 10

                              200-6311-9UN-1900                                      11 x 11

                              200-6313-9UN-1900                                      13 x 13

                              200-6315-9UN-1900                                      15 x 15

                              200-6317-9UN-1900                                      17 x 17    Socket Kit W/O Contacts

                              200-6319-9UN-1900                                      19 x 19

                              200-6321-9UN-1900                                      21 x 21

                              200-6325-9UN-1900                                      25 x 25

                              300-6300-CNA-0002B                                     Each       Contact–BeCu/Au Plated

                              200-4660-14-1900                                    Set of 10     Extra Hole Plugs

                                                                                                                                  TS-0675-09

                                                                                                                                  Sheet 2 of 2

3M Electronic Handling and Protection Division

6801 River Place Blvd.                                                For technical, sales or ordering information call 800-328-0411

Austin, TX 78726-9000                                                                           or visit our website:   http://www.3M.com/ehpd
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

3M:

200-4660-14-1900  200-6310-9UN-1900  200-6311-9UN-1900  200-6313-9UN-1900  200-6315-9UN-1900  200-6317-

9UN-1900  200-6319-9UN-1900  200-6321-9UN-1900  200-6325-9UN-1900  300-6300-CNA-0002B

小广播

200-6315-9UN-1900器件购买:

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved