Pressure Sensors 19 mm Series
Low-Cost, Stainless Steel, Isolated Sensors
FEATURES Honeywell's stainless steel 19C, 19U, and 19 Vacuum Gage Series
Low cost sensors were developed for pressure applications that involve measurement
Rugged, isolated stainless of hostile media in harsh environments compatible with 316 stainless steel.
The special Vacuum Gage Series sensors are specifically designed for
steel package applications that can be exposed to vacuum.
Small size
Reliable semiconductor The 19C Series are calibrated and temperature compensated. They are
available for use with either a constant voltage or current source. They
technology feature a variety of pressure connections to allow use in a wide range of
Calibrated and OEM (Original Equipment Manufacturer) equipment. The 19U Series is
uncompensated for applications that use their own specialized circuit
temperature compensated designs.
Absolute and gage
The 19C and 19U Series sensors are rugged and reliable transducers for
pressures use in a wide variety of pressure sensing applications where corrosive
Vacuum compatible, liquids or gases are monitored.
isolated sensors 19C, 19U, AND 19 VACUUM GAGE EQUIVALENT CIRCUIT
0 psi to 3 psi to, 0 psi to
500 psi
TYPICAL APPLICATIONS
Industrial controls
Process control systems
Industrial automation and
flow control
Pressure calibrators
WARNING WARNING
PERSONAL INJURY MISUSE OF DOCUMENTATION
DO NOT USE these The information presented in this product sheet is for reference only. Do
products as safety or
emergency stop devices or not use this document as a product installation guide.
in any other application Complete installation, operation, and maintenance information is provided
where failure of the product
could result in personal in the instructions supplied with each product.
injury. Failure to comply with these instructions could result in death or
Failure to comply with serious injury.
these instructions could
result in death or serious
injury.
Sensing and Control
Pressure Sensors 19 mm Series
Low-Cost, Stainless Steel, Isolated Sensors
PRESSURE SENSOR CHARACTERISTICS ALL DEVICES
Environmental specifications
Compensated temperature range 0 C to 82 C [32 F to 180 F]
Operating temperature range -40 C to 125 C [-40 F to 257 F]
Storage temperature range -40 C to 125 C [-40 F to 257 F]
Vibration 10 G at 20 Hz to 2000 Hz
Shock 100 G for 11 ms
Life 1 million cycles min.
Insulation resistance 100 m at 50 Vdc
Maximum ratings
Voltage version "K" Supply voltage VS = +15 Vdc
Voltage version "L" Supply current IS = +2.0 mA
PRESSURE RANGE SPECIFICATIONS (19C, 19U)
Catalog Listing Pressure range Proof pressure (7) Burst pressure (8)
9 psig 15 psig
19(C,U) 003P G (1...9) (K/L) 0 psig to 3 psig 15 psig 25 psig
30 psig 50 psig
19(C,U) 005P G (1...9) (K/L) 0 psig to 5 psig 45 psi 75 psi
90 psi 150 psi
19(C,U) 010P G (1...9) (K/L) 0 psig to 10 psig 150 psi 250 psi
300 psi 500 psi
19(C,U) 015P (A,G,V) (1...9) (K/L) 0 psi to 15 psi 600 psi 1000 psi
900 psi 1500 psi
19(C,U) 030P (A,G,V) (1...9) (K/L) 0 psi to 30 psi 1200 psi 2400 psi
19(C,U) 050P (A,G,V) (1...9) (K/L) 0 psi to 50 psi
19(C,U) 100P (A,G,V) (1...9) (K/L) 0 psi to 100 psi
19(C,U) 200P (A,G,V) (1...9) (K/L) 0 psi to 200 psi
19(C,U) 300P (A,G,V) (1...9) (K/L) 0 psi to 300 psi
19(C,U) 500P (A,G,V) (1...9) (K/L) 0 psi to 500 psi
Notes:
7. The maximum pressure that can be applied without changing the transducer's performance or accuracy.
8.The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer case.
19C SERIES PERFORMANCE CHARACTERISTICS (1) Minimum Typical Maximum Unit
-2 0 2 mV
Characteristic 98 100 102 mV
Zero pressure offset 48 50 52 mV
Full-scale span (2) 0.1 0.25 %FSS
Full-scale span (3 psi and 5 psi "K" units only) (2) 0.015 0.030 %FSS
Pressure non-linearity (3) 0.010 0.030 %FSS
Pressure hysteresis (3) 0.5 1.0 %FSS
Repeatability 0.5 1.0 %FSS
Temp. effect on span (4) 2.0 %FSS
Temp. effect on offset (4) 2.0 %FSS
Temp. effect on span (0 psi to 3 psi and 0 psi to 5 psi only) (4) 0.1 0.3 %FSS
Temp. effect on offset (0 psi to 3 psi and 0 psi to 5 psi only) (4) 0.1 0.3 %FSS
0.1 ms
Thermal hysteresis (0 C to 82 C [32 F to 180 F]) 0.5 1.3 2.0 Vdc
Long-term stability of offset and span (5) 2.0 4.5 8.0 k
Response time (6) 8.0 25 50 k
Common mode voltage (voltage version "K") (9) 3.0 4.5 6.0 k
Input impedance (current version "L")
Input impedance (voltage version "K")
Output resistance
2 Honeywell Sensing and Control
Pressure Sensors 19 mm Series
Low-Cost, Stainless Steel, Isolated Sensors
19U SERIES PERFORMANCE CHARACTERISTICS (1) Minimum Typical Maximum Unit
-7.5 1.0 7.5 mV/V
Characteristic 35 40 60 mV/V
Zero pressure offset 20 30 40 mV/V
Full-scale span (2) 0.1 0.25 %FSS
Full-scale span (3 psi and 5 psi only) (2) 0.015 0.030 %FSS
Pressure non-linearity (3) 0.010 0.030 %FSS
Pressure hysteresis (3) 2700 3420 4500 ppm/C
Repeatability 30 V/V/C
Temp. coefficient of resistance (10) (0 C to 82 C [32 F to 180 F]) 360 720 1260 ppm/C
Temp. coefficient of offset (10) (0 C to 82 C [32 F to 180 F]) 0.1 0.3 %FSS
Temp. coefficient of span (10) (0 C to 82 C [32 F to 180 F]) 0.1 0.3 %FSS
Thermal hysteresis (0 C to 82 C [32 F to 180 F]) 0.1 ms
Long-term stability of offset and span (5) 4.00 4.75 6.0 k
Response time (6) 4.00 4.75 6.0 k
Input resistance
Output resistance
19C VACUUM GAGE COMPENSATED SERIES PERFORMANCE CHARACTERISTICS (1)
Characteristic Minimum Typical Maximum Unit
mV
Zero pressure offset (at 0 psig) -2 0 2 mV
Full-scale span (2) (0 psig to positive full-scale) %FSS
Pressure non-linearity (3) 98 100 102 %FSS
Pressure hysteresis (3) %FSS
0.1 0.25 %FSS
%FSS
0.015 0.030 %FSS
%FSS
Repeatability 0.010 0.030 ms
Temp. effect on span (4) Vdc
Temp. effect on offset (4) 0.5 1.0 k
k
0.5 1.0 k
Thermal hysteresis (0 C to 82 C [32 F to 180 F]) 0.1 0.3
Long-term stability of offset and span (5)
Response time (6) 0.1 0.3
Common mode voltage (voltage version "K") (9)
0.1
0.5 1.3 2.0
Input impedance (current version "L") 1.5 4.5 8.0
Input impedance (voltage version "K") 8.0 25 50
Output resistance 3.0 4.5 6.0
19U VACUUM GAGE UNCOMPENSATED SERIES PERFORMANCE CHARACTERISTICS (1)
Characteristic Minimum Typical Maximum Unit
mV/V
Zero pressure offset -7.5 1.0 7.5 mV/V
Full-scale span (2) (0 psig to positive full-scale) %FSS
Pressure non-linearity (3) 35 40 60 %FSS
Pressure hysteresis (3) %FSS
0.1 0.25 ppm/C
V/V/C
0.015 0.030 ppm/C
%FSS
Repeatability 0.010 0.030 %FSS
Temp. coefficient of resistance (10) (0 C to 82 C [32 F to 180 F]) 2700 3420 4500 ms
Temp. coefficient of offset (10) (0 C to 82 C [32 F to 180 F]) 30 k
Temp. coefficient of span (10) (0 C to 82 C [32 F to 180 F]) 360 720 1260 k
Thermal hysteresis (0 C to 82 C [32 F to 180 F]) 0.1 0.3
Long-term stability of offset and span (5)
Response time (6) 0.1 0.3
0.1
Input resistance 4.00 4.75 6.0
Output resistance 4.00 4.75 6.0
Honeywell Sensing and Control 3
Pressure Sensors 19 mm Series
Low-Cost, Stainless Steel, Isolated Sensors
NOTES
1. Reference conditions (unless otherwise noted): TA = 25 C [77 F]; 19C Supply VS = 10 Vdc 0.01 Vdc or
IS = 1.5 mA 0.0015 mA; 19U Supply VS = 5 Vdc 0.01 Vdc or I = 1.0 mA 0.0015 mA
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
pressure. FSS is ratiometric to supply voltage.
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
maximum output difference at any point within the operation pressure range for increasing and decreasing pressure.
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 C [77 F]
reading.
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10 % to 90 % rise time.
9. Common mode voltage as measured from output to ground. For higher levels of common mode voltage, contact factory.
10. The error band resulting from a maximum deviation of a transducer's output parameter (offset, span, or resistance) as
temperature is varied 25 C [77 F] to any other temperature within the specified range (0 C to 82 C [32 F to 180 F]).
This parameter is not 100 % tested and is guaranteed by process design and tested on a sample basis only.
Temperature coefficient of span is evaluated using a constant current source.
PHYSICAL DIMENSIONS, for reference only, mm [in]
Package 1 (see note): Cell Package
Note: Non-concentricity effects at the diaphragm weld area may cause runout of up to 0.006 in between the upper and lower portions of
the sensor body. (It is recommended to use a counter bore to mate with this device to allow for this non-concentricity).
Package 2: Flush Mount Package
4 Honeywell Sensing and Control
Pressure Sensors 19 mm Series
Low-Cost, Stainless Steel, Isolated Sensors
Package 3: Flush Mount with Flange
Package 4: Male 1/8-27 NPT
Package 5: Male 1/4-18 NPT
Honeywell Sensing and Control 5
Pressure Sensors 19 mm Series
Low-Cost, Stainless Steel, Isolated Sensors
Package 6: Male 7/16 UNF
Package 7: Male 1/4 BSPP
Package 8: Euro Ring (See note)
Note: Non-concentricity effects at the diaphragm weld area may cause runout of up to 0.006 in between the upper and
lower portions of the sensor body. (It is recommended to use a counter bore to mate with this device to allow for this non-
concentricity).
6 Honeywell Sensing and Control
Pressure Sensors 19 mm Series
Low-Cost, Stainless Steel, Isolated Sensors
Package 9: VCR Gland (Female nut)
ORDERING INFORMATION
Honeywell Sensing and Control 7
Pressure Sensors 19 mm Series
Low-Cost, Stainless Steel, Isolated Sensors
WARRANTY/REMEDY While we provide application assistance personally,
Honeywell warrants goods of its manufacture as through our literature and the Honeywell web site, it
being free of defective materials and faulty is up to the customer to determine the suitability of
workmanship. Contact your local sales office for the product in the application.
warranty information. If warranted goods are For application assistance, current specifications, or
returned to Honeywell during the period of coverage, name of the nearest Authorized Distributor, contact a
Honeywell will repair or replace without charge those nearby sales office. Or call:
items it finds defective. The foregoing is Buyer's
sole remedy and is in lieu of all other warranties, 1-800-537-6945 USA/Canada
expressed or implied, including those of 1-815-235-6847 International
merchantability and fitness for a particular FAX
purpose. 1-815-235-6545 USA
Specifications may change without notice. The INTERNET
information we supply is believed to be accurate and www.honeywell.com/sensing
reliable as of this printing. However, we assume no info.sc@honeywell.com
responsibility for its use.
Sensing and Control
www.honeywell.com/sensing
Honeywell
11 West Spring Street
Freeport, Illinois 61032
008132-1-EN IL50 GLO 1004 Printed in USA
Copyright 2004 Honeywell International Inc. All Rights Reserved.
This datasheet has been downloaded from:
www.EEworld.com.cn
Free Download
Daily Updated Database
100% Free Datasheet Search Site
100% Free IC Replacement Search Site
Convenient Electronic Dictionary
Fast Search System
www.EEworld.com.cn
All Datasheets Cannot Be Modified Without Permission
Copyright Each Manufacturing Company