电子工程世界电子工程世界电子工程世界

型号

产品描述

搜索

179-NISTW-DATA

器件型号:179-NISTW-DATA
器件类别:测试与测量    万用表与电压表   
厂商名称:Fluke [FLUKE]
下载文档

器件描述

Digital Multimeters TRMS MULTIMETER CALIBTRATED W/DATA

参数

产品属性属性值
产品种类:
Product Category:
Digital Multimeters
制造商:
Manufacturer:
Fluke
RoHS:YES
产品:
Product:
Multimeters
类型:
Type:
Hand Held
Accuracy:+/- 1 %
Voltage Range:0.1 mVAC to 1000 VAC
Resistance Range:0.1 Ohms to 50 MOhms
Capacitance Range:1 nF to 9999 uF
Display Count:6000
Frequency:2 Hz to 50 kHz
Ranging:Auto, Manual
True RMS:True RMS
Data Hold:Data Hold
AC Supply Voltage:1000 V
商标:
Brand:
Fluke
电流额定值:
Current Rating:
10 mA
系列:
Series:
170
工厂包装数量:
Factory Pack Quantity:
1
电压额定值:
Voltage Rating:
1000 VAC
零件号别名:
Part # Aliases:
1256480

179-NISTW-DATA器件文档内容

Page 1 of 3, Document #2155

170 Series True-rms DMMs

Extended Specifications

©2000 Fluke Corporation

Rev. A-11/2000

                                             Fluke 170 Series

                          True-rms Digital Multimeter

                                Extended Specifications

Model Differences

(all other specifications are the same for each model)

Feature                                                    Model

                                      175                  177                179

Backlight                                                  •                       •

Temperature Measurement                                                            •

Basic dc voltage accuracy             0.15%       0.09%                       0.09%

Nominal Specifications

Function                                          Absolute Range or Description

AC Voltage, True-rms            0.1 mV to 1000V   (1 kHz)

DC Voltage                      0.1 mV to 1000V

Continuity                      Beeper guaranteed on < 25 Ω, guaranteed off > 250 Ω;

                                detects opens or shorts of 250 µs or longer.

Resistance                      0.1Ω to 50.00 MΩ

Diode Test                      2.400V

Capacitance                     1 nF to 9999 uF

AC Current, True-rms            0.01 mA to 10.00A (20.00 A over-range for 30 seconds)

DC Current                      0.01 mA to 10.00A (20.00 A over-range for 30 seconds)

Frequency                       2 Hz to 50 kHz

Temperature (179 Only)          -40 ºC to +400 ºC; -40 ºF to +752 ºF

Basic dc voltage accuracy       0.15% (175)                                0.09% (177 & 179)

Basic ac voltage accuracy       1.0%

Features

Feature                         Description

Digital Display                 6000 counts, updates 4 x second

Analog Bargraph Display         33 segments, updates 40 x second

Backlight (177 & 179 only)      Automatically turns off after 2 minutes to save battery life

                                The timeout feature can be disabled with a power-up option

HOLD & Auto HOLD                HOLD: freezes the display at the push of a button

                                Auto HOLD: Display holds present reading until it detects new stable input,

                                then the meter beeps and displays new reading

MIN MAX AVG                     Minimum, maximum, and average reading memory

Manual or auto ranging          In auto range, the meter selects the range with the best resolution for

                                the present measurement value

Fast continuity/open detection  The beeper sounds with a stretched pulse for opens or shorts as

                                brief as 250 µs

Test lead alert                 The message “LEAd” appears briefly on the display when the rotary switch

                                is moved to or from any A (Amps) position

Power-up options                (1) Turn on all LCD segments, (2) Disable beeper, (3) Disable sleep mode,

                                (4) Enable smoothing, (5) Disable backlight timeout (Models 177 & 179 only)

Closed-case calibration         No internal adjustments needed

Probe holders                   The instrument comes with built-in probe holders for probe storage and

                                for convenience when making measurements

Battery access door             Battery replacement without voiding calibration

High-impact overmold case       Integrated overmolded protection provides superior impact protection for

                                your meter
Page 2 of 3, Document #2155

170 Series True-rms DMMs

Extended Specifications

©2000 Fluke Corporation

Rev. A-11/2000

General Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative

humidity of               0 % to 75 %. Accuracy specifications take the form of:  ±  ( [ % of Reading ] + [ Counts ] )

Maximum voltage between any     1000V  DC or AC RMS

terminal and earth ground

Surge Protection                8 kV peak per IEC 61010

Fuse for mA inputs              440 mA, 1000 V FAST Fuse

Fuse for A input                11A, 1000V FAST Fuse

Display                         Digital: 6,000 counts, updates 4/sec

                                Bar Graph: 33 segments, updates 40/sec

                                Frequency: 9,999 counts

                                Capacitance: 9,999 counts

Altitude                        Operating: 2000 m; Storage: 12000 m

Temperature                     Operating: -10 °C to +50 °C

                                Storage: -30 °C to +60 °C

Temperature coefficient         0.1 X (specified accuracy / °C)

                                (< 18 °C or > 28 °C)

Electromagnetic Compatibility   In an RF field of 3 V/M, accuracy = specified accuracy except in

(EN 61326-1:1997)               temperature: specified accuracy ± 5 °C, ± 9 °F

Relative Humidity               0 % to 90 % @  0 °C to 35 °C;

                                0 % to 70 % @  36 °C to 50 °C

Relative Humidity in            0 % to 80 %  @ 0°C to 35°C;
50 MΩ Range
                                0 % to 70 %  @ 36 °C to 50 °C

Battery Life                    Alkaline: ~200 hrs typical

Size, with Holster (H x W x L)  4.3 cm x    9 cm x 18.5 cm

Weight                          420g

Safety Compliances              ANSI/ISA S82.02.01, CSA C22.2-1010.1, IEC 61010 to 1000 V Overvoltage

                                Category III, 600 V Overvoltage Category IV

Certifications                  CSA, TÜV (EN61010),

                                Australian   (N10140)
Page 3 of 3, Document #2155

170 Series True-rms DMMs

Extended Specifications

©2000 Fluke Corporation

Rev. A-11/2000

Detailed Specifications

                                                                      Accuracy     ± ( [ % of Reading ] + [ Counts ] )

Function                     Range 1                      Resolution  Model 175               Model 177              Model 179

AC Volts 2                   600.0 mV                     0.1 mV      1.0 % + 3               1.0 % + 3              1.0 % + 3

                             6.000V                       0.001V      (45 Hz to 500 Hz)       (45 Hz to 500 Hz)      (45 Hz to 500 Hz)

                             60.00V                       0.01V

                             600.0V                       0.1V

                             1000V                        1V          2.0 % + 3               2.0 % + 3              2.0 % + 3

                                                                      (500 Hz to 1 kHz)       (500 Hz to 1 kHz)      (500 Hz to 1 kHz)

DC mV                        600.0 mV                     0.1 mV      0.15 % + 2              0.09 % + 2             0.09 % + 2

DC Volts                     6.000V                       0.001V      0.15 % + 2              0.09 % + 2             0.09 % + 2

                             60.00V                       0.01V

                             600.0V                       0.01V

                             1000V                        1V          0.15 % + 2              0.1 % + 2              0.1 % + 2

Continuity                   600Ω                         1Ω          Meter beeps at < 25 Ω, beeper turns off at > 250 Ω;

                                                                      detects opens or shorts of 250 ms or longer.

Ohms                         600.0Ω                       0.1Ω        0.9 % + 2               0.9 % + 2              0.9 % + 2

                             6.000 kΩ                     0.001 kΩ    0.9 % + 1               0.9 % + 1              0.9 % + 1

                             60.00 kΩ                     0.01 kΩ     0.9 % + 1               0.9 % + 1              0.9 % + 1

                             600.0 kΩ                     0.1 kΩ      0.9 % + 1               0.9 % + 1              0.9 % + 1

                             6.000 MΩ                     0.001 MΩ    0.9 % + 1               0.9 % + 1              0.9 % + 1

                             50.00 MΩ                     0.01 MΩ     1.5 % + 3               1.5 % + 3              1.5 % + 3

Diode test                   2.400V                       0.001V      1%+2

Capacitance                  1000 nF                      1 nF        1.2 % + 2               1.2 % + 2              1.2 % + 2

                             10.00 µF                     0.01 µF     1.2 % + 2               1.2 % + 2              1.2 % + 2

                             100.0 µF                     0.1 µF      1.2 % + 2               1.2 % + 2              1.2 % + 2

                             9999 µF 3                    1 µF        10 % typical            10 % typical           10 % typical

AC Amps                      60.00 mA                     0.01 mA     1.5 % + 3               1.5 % + 3              1.5 % + 3

(True-rms)                   400.0 mA                     0.1 mA

                             (600 mA for 18 hrs)          0.001A

                             6.000A

(45 Hz to 1 kHz)             10.00A                       0.01A

                             (20A for 30s)

DC Amps                      60.00 mA                     0.01 mA     1.0 % + 3               1.0 % + 3              1.0 % + 3

                             400.0 mA                     0.1 mA

                             (600 mA for 18 hrs)

                             6.000A                       0.001A

                             10.00A                       0.01A

                             (20A for 30s)

Hz                           99.99 Hz                     0.01 Hz     0.1 % + 1               0.1 % + 1              0.1 % + 1

(AC- or DC-                  999.9 Hz                     0.1 Hz

coupled,                     9.999 kHz                    0.001 kHz

V or A 4, 5 input )          99.99 kHz                    0.01 kHz

Temperature                  -40 °C to +400 °C            0.1 °C      NA                      NA                     1 % + 1.0 °C

                             -40 °F to +752 °F            0.1 °F                                                     1 % + 1.8 °F

MIN MAX AVG                  For DC functions, accuracy is the specified of the measurement function ± 12 counts for changes

                             longer than 275 ms in duration.

                             For AC functions, accuracy is the specified of the measurement function ± 40 counts for changes

                             longer than 1.2 s in duration.

1. All AC voltage and AC current ranges are specified from 5 % of range to 100 % of range.                                              Fluke. Keeping your world

2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor ≤ 1.5 at              1000 V.                     up and running.

3. In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2 % for all models.

4. In mA and A ranges, frequency measurement is specified to 30 kHz.

5. Frequency < 10 kHz are not specified in 600 mV AC, 60 mA AC, and 6 A AC ranges.

Function                 Overload Protection  1  Input Impedance      Common Mode Rejection Ratio           Normal Mode Rejection       Fluke Corporation

                                                 (Nominal)            (1 kΩ Unbalanced)                                                 PO Box 9090, Everett, WA USA 98206

Volts AC                 1000 V RMS or DC        > 10 MΩ < 100 pF     > 60 dB @ DC, 50 or 60 Hz                                         Fluke Europe B.V.

                                                                                                                                        PO Box 1186, 5602 BD

Volts DC                 1000 V RMS or DC        > 10 MΩ <100 pF      >120 dB @ DC, 50 or 60 Hz             > 60 dB @ 50 Hz or 60 Hz    Eindhoven, The Netherlands

                                                 Open Circuit Test    Full Scale Voltage To:                Short Circuit Current       For more information call:

                                                 Voltage              6.0 MΩ        50 MΩ                                               U.S.A. (800) 443-5853 or

Ohms                     1000V RMS or DC         < 1.5 V DC           < 600 mV DC   < 1.5 V DC              < 500 µA                    Fax (425) 446-5116

                                                                                                                                        Europe (31 40) 2 675 200 or

Diode test 1000V RMS or DC                       2.4 to 3.0 V DC      2.4 V DC                              < 1.2 mA typical            Fax (31 40) 2 675 222

1. 10 7 V-Hz maximum.                                                                                                                   Canada (905) 890-7600 or

                                                                                                                                        Fax (905) 890-6866

                                                                                                                                        Other countries (425) 446-5500 or

                                                                                                                                        Fax (425) 446-5116

                                                                                                                                        Web access: http://www.fluke.com

                                                                                                                                        ©2001 Fluke Corporation. All rights reserved.

                                                                                                                                        Specifications subject to change without notice.

                                                                                                                                        Printed in U.S.A.  3/2001

                                                                                                                                        Printed on recycled paper.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory,  Delivery  &  Lifecycle  Information:

Fluke:

179-NISTW/DATA

179-NISTW-DATA器件购买:

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved