器件描述

Test Leads RETRACT TEST LEADS

参数

产品属性属性值
产品种类:
Product Category:
Digital Multimeters
制造商:
Manufacturer:
Fluke
RoHS:YES
产品:
Product:
Multimeters
类型:
Type:
Hand Held
Accuracy:AC 2 %, DC 1 %
Voltage Range:0.1 mV to 1 kV
Resistance Range:0.1 Ohms to 50 MOhms
商标:
Brand:
Fluke
工厂包装数量:
Factory Pack Quantity:
1
零件号别名:
Part # Aliases:
2157280
单位重量:
Unit Weight:
1.213 lbs

1577器件文档内容

1587/1577

Insulation Multimeters

                                                                                                 Technical          Data

                                                             Two powerful tools in one.

                                                             The Fluke 1587 and 1577 Insulation

                                                             Multimeters combine a digital

                                                             insulation tester with a full-featured,

                                                             true-rms digital multimeter in a

                                                             single compact, handheld unit,

                                                             which provides maximum versatility

                                                             for both troubleshooting and

                                                             preventative maintenance.

                                                                Like other tools that you have

                                                             come to expect from Fluke, the

                                                             1587 and 1577 are rugged, reliable

                                                             and easy to use.

                                                                Whether you work on motors,

                                                             generators, cables or switch-gear,

                                                             the Fluke 1587/1577 Insulation

                                                             Multimeters are ideally suited to

                                                             help you with your tasks.

•  Large display with backlight                              •  Capacitance, diode test, temperature, Min/Max,

•  Insulation test (1587: 0.01 MΩ to 2 GΩ)                      frequency (Hz) (1587 only)

   (1577: 0.1 MΩ to 600 MΩ)                                  •  Auto power off to save battery power

•  Insulation test voltages (1587: 50 V, 100 V, 250 V,       •  CAT III 1000 V, CAT IV 600 V measurement category

   500 V, 1000 V),(1577: 500 V, 1000 V) for many             •  Included accessories: Remote probe, test leads

   applications                                                 and probes, alligator clips, (K-type thermocouple,

•  Live circuit detection prevents insulation test if volt-     1587 only)

   age > 30 V is detected for added user protection          •  Accepts optional Fluke TPAK™ magnetic hanging

•  Auto-discharge of capacitive voltage for added user          system to free your hands for other work

   protection                                                •  Rugged, utility hard case allows you to bring

•  AC/DC voltage, DC milliVolts, AC/DC milliamps,               everything you need for the job

   Resistance (Ω), Continuity                                •  Three year warranty

•  Filter for motor drive measurements (1587 only)
                      1587/1577 Specifications

                      AC voltage measurement

                      1587 accuracy

                            Range                            Resolution                   50 Hz to 60 Hz          60 Hz to 5000 Hz

                            600.0 mV                         0.1 mV                       + (1 % + 3)             + (2 % + 3)

                            6.000 V                          0.001 V                      + (1 % + 3)             + (2 % + 3)

                            60.00 V                          0.01 V                       + (1 % + 3)             + (2 % + 3)

                            600.0 V                          0.1 V                        + (1 % + 3)             + (2 % + 3)1

                            1000 V                           1V                           + (2 % + 3)             + (2 % + 3)1

                      11 kHz bandwidth

                      1587  lowpass filter        Voltage

                            Range                            Resolution                   50 Hz to 60 Hz          60 Hz to 400 Hz

                                                                                       ±  (% of Rdg + Digits)  ±  (% of Rdg + Digits)

                            600.0 mV                         0.1 mV                       ± (1 % + 3)             + (2 % + 3)

                                                                                                                  – (6 % – 3)

                            6.000 V                          0.001 V                      ± (1 % + 3)             + (2 % + 3)

                                                                                                                  – (6 % – 3)

                            60.00 V                          0.01 V                       ± (1 % + 3)             + (2 % + 3)

                                                                                                                  – (6 % – 3)

                            600.0 V                          0.1 V                        ± (1 % + 3)             + (2 % + 3)

                                                                                                                  – (6 % – 3)

                            1000 V                           1V                           ± (2 % + 3)             + (2 % + 3)

                                                                                                                  – (6 % – 3)

                      1577 accuracy

                                        Range                                 Resolution                       50 Hz to 60 Hz

                                        600.0 mV                              0.1 mV                           ± (2 % + 3)

                                        6.000 V                               0.001 V                          ± (2 % + 3)

                                        60.00 V                               0.01 V                           ± (2 % + 3)

                                        600.0 V                               0.1 V                            ± (2 % + 3)

                                        1000 V                                1V                               ± (2 % + 3)

                      AC conversion: Inputs are ac-coupled and calibrated to the rms value of sine wave input. Conversions are

                      true-rms responding and specified from 5 % to 100 % of range. Input signal crest factor can be up to 3 at

                      up to 500 V, decreasing linearly to crest factor <= 1.5 at 1000 V. For non-sinusoidal waveforms add ± (2 %

                      reading + 2 % FS) typical, for a crest factor up to 3.

                      Input impedance: 10 MΩ (nominal), < 100 pF, ac-coupled

                      Common mode rejection ratio (1 kΩ unbalanced): > 60 dB at dc, 50 or 60 Hz

                      Overload protection: 1000 V rms or dc, 107 V Hz Max

                      DC voltage measurement

                            Range                            Resolution                   Accuracy 15871          Accuracy 15771

                            6.000 V dc                       0.001 V                      ± (0.09 % + 2)          ± (0.2 % + 2)

                            60.00 V dc                       0.01 V                       ± (0.09 % + 2)          ± (0.2 % + 2)

                            600.0 V dc                       0.1 V                        ± (0.09 % + 2)          ± (0.2 % + 2)

                            1000 V dc                        1V                           ± (0.09 % + 2)          ± (0.2 % + 2)

                      1Accuracies apply to ± 100 % of range

                      Input impedance: 10 MΩ (nominal), < 100 pF

                      Normal mode rejection ratio: > 60 dB @ 50 Hz or 60 Hz

                      Common rode rejection ratio: > 120 dB @ dc, 50 Hz or 60             Hz (1 kΩ unbalance)

                      Overload protection: 1000 V rms or dc

                      DC    millivolts            measurement

                            Range                            Resolution                   Accuracy 1587           Accuracy 1577

                            600.0 mV dc                      0.1 mV                       ± (0.1 % + 1)           ± (0.2 % + 1)

2  Fluke Corporation  1587/1577 Insulation Multimeters
DC and ac current measurement

                                                                    Accuracy 1587       Accuracy 1577                     Burden Voltage

    Range                                   Resolution             ± (% of Rdg+Digits)  ± (% of Rdg+Digits)               (Typical)

AC                400 mA                    0.1 mA                  ± (1.5 % + 2)1      ± (2 % + 2)1                      2 mV/mA

45 to 1000 Hz     60 mA                     0.01 mA                 ± (1.5 % + 2)1      ± (2 % + 2)1

DC                400 mA                    0.1 mA                  ± (0.2 % + 2)       ± (1.0 % + 2)                     2 mV/mA

                  60 mA                     0.01 mA                 ± (0.2 % + 2)       ± (1.0 % + 2)

11 kHz bandwidth

Overload: 600 mA for 2 minutes maximum

Overload protection: 440 mA, 1000 V, FAST fuse

AC conversion: Inputs are ac-coupled and calibrated to the rms value of sine wave input. Conversions are

true-rms responding and specified from 5 % to 100 % of range. Input signal crest factor can be up to 3 at up

to 300 mA, decreasing linearly to crest factor < = 1.5 at 600 mA. For non-sinusoidal waveforms add + (2 %

reading + 2 % FS) typical, for a crest factor up to 3.

Ohms measurement

                                                                    Accuracy 15871      Accuracy 15771

    Range                                   Resolution             ± (% of Rdg+Digits)  ± (% of Rdg+Digits)

    600.0 Ω                                 0.1 Ω

    6.000 kΩ                                0.001 kΩ

    60.00 kΩ                                0.01 kΩ                 ± (0.9 % + 2)       ± (1.2 % + 2)

    600.0 kΩ                                0.1 kΩ

    6.000 MΩ                                0.001 MΩ

    50.0 MΩ                                 0.01 MΩ                 ± (1.5 % + 3)       ± (2.0 % + 3)

1Accuracies apply from 0 to 100 % of range

Overload protection: 1000 V rms or dc

Open circuit test voltage: < 8.0 V dc

Short circuit current: < 1.1 mA

Diode test (1587 Only)

Diode test indication: Display voltage drop: 0.6 V at 1.0 mA nominal test current

Accuracy: + (2 % + 3)

Continuity test

Continuity indication: Continuous audible tone for test resistance below 25 Ω and       off above 100 Ω.

Maximum reading; 1000 Ω

Open circuit voltage: < 8.0 V

Short circuit current: 1.0 mA typical

Overload protection: 1000 V rms

Response time: > 1 m sec

Frequency measurement                                   (1587 only)

                                                                                        Accuracy

                  Range                                 Resolution                      ± (% of Rdg+Digits)

                  99.99 Hz                              0.01 Hz                         ± (0.1 % + 1)

                  999.9 Hz                              0.1 Hz                          ± (0.1 % + 1)

                  9.999 kHz                             0.001 kHz                       ± (0.1 % + 1)

                  99.99 kHz                             0.01 kHz                        ± (0.1 % + 1)

                                                                                        1587/1577 Insulation Multimeters  Fluke Corporation  3
                      1587/1577 Specifications cont.

                      Frequency counter sensitivity

                                                                      V ac Sensitivity (RMS Sinewave)1                                  DC Trigger Levels

                      Input Range                                5    Hz to 20 kHz              20 kHz to 100 kHz                       to 20 kHz2

                      600.0 mV ac                                     100.0 mV                  150.0 mV                                N/A

                      6.0 V                                           1.0 V                     1.5 V                                   -400.0 mV and 2.5 V

                      60.0 V                                          10.0 V                    36.0 V                                  1.2 V and 4.0 V

                      600.0 V                                         100.0 V                   –                                       12.0 V and 40.0 V

                      1000.0 V                                        300.0 V                   –                                       12.0 V and 40.0 V

                      1Maximum input for specified accuracy =    10x  range (1000 V max). Noise at low frequencies and amplitudes  may affect accuracy.

                      2Usable to 100 kHz with full scale input.

                      Capacitance  (1587                         only)

                      Range                                                         Resolution                     ± (% of Rdg+Digits)

                      1000 nF                                                       1 nF

                      10.00 µF                                                      0.01 µF                                             ± (1.2 % + 2)

                      100.0 µF                                                      0.1 µF

                      9999 µF                                                       1 µF                           ± (1.2 % +/- 90 counts)

                      Temperature measurement (1587 only)

                      Range                                                         Resolution                                          Accuracy1

                      -40 °C to 537 °C                                              0.1 °C                                         ± (1 % + 10 counts)

                      -40 °F to 998 °F                                              0.1 °F                                         ± (1 % + 18 counts)

                      1Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument

                      Insulation specifications

                      Measurement range: 1587: 0.01 MΩ to 2 GΩ , 1577: 0.1 MΩ to 600 MΩ

                      Test voltages: 50, 100, 250, 500, 1000 V model 1587, 500 and 1000 V model 1577

                      Test voltage accuracy: + 20 %, - 0 %

                      Short-circuit test current: 1 mA nominal

                      Auto discharge: Discharge time < 0.5 second for C = 1 µF or less

                      Live circuit detection: Inhibit test if terminal voltage > 30 V prior to initialization of test

                      Maximum capacitive load: Operable with up to 1 µF load

4  Fluke Corporation  1587/1577 Insulation Multimeters
Model 1587

Output Voltage      Display Range                         Resolution                   Test Current        Resistance Accuracy

       50 V         0.01 to 6.00 MΩ                       0.01 MΩ                      1 mA @ 50 kΩ        ± (3 % + 5 counts)

(0 % to + 20 %)     6.0 to 50.0 MΩ                        0.1 MΩ

                    0.01 to 6.00 MΩ                       0.01 MΩ

       100 V        6.0 to 60.0 MΩ                        0.1 MΩ                      1 mA @ 100 kΩ        ± (3 % + 5 counts)

(0 % to + 20 %)     60 to 100 MΩ                          1 MΩ

       250 V        0.1 to 60.0 MΩ                        0.1 MΩ                      1 mA @ 250 kΩ        ± (1.5 % + 5 counts)

(0 % to + 20 %)     60 to 250 MΩ                          1 MΩ

       500 V        0.1 to 60.0 MΩ                        0.1 MΩ                      1 mA @ 500 kΩ        ± (1.5 % + 5 counts)

(0 % to + 20 %)     60 to 500 MΩ                          1 MΩ

                    0.1 to 60.0 MΩ                        0.1 MΩ                                           ± (1.5 % + 5 counts)

       1000 V       60 to 600 MΩ                          1 MΩ                         1 mA @ 1 MΩ

(0 % to + 20 %)     0.6 to 2.0 GΩ                         100 MΩ                                           ± (10 % + 3 counts)

Model 1577

Output Voltage      Display Range                         Resolution                   Test Current        Resistance Accuracy

       500 V        0.1 to 60.0 MΩ                        0.1 MΩ                      1 mA @ 500 kΩ        ± (2.0 % + 5 counts)

(0 % to + 20 %)     60 to 500 MΩ                          1 MΩ

       1000 V       0.1 to 60.0 MΩ                        0.1 MΩ                       1 mA @ 1 MΩ         ± (2.0 % + 5 counts)

(0 % to + 20 %)     60 to 600 MΩ                          1 MΩ

1587/1577 General Specifications

Maximum voltage applied to any terminal: 1000 V ac rms                Certifications: CSA per standard CSA/CAN C22.2

or dc                                                                 No. 61010.1-04; TUV per standard EN 61010 Part 1-1002

Storage temperature: -40 °C to 60 °C (-40 °F to 140 °F)               Batteries: Four AA batteries (NEDA 15A or IEC LR6)

Operating temperature: -20 °C to 55 °C (-4 °F to 131 °F)              Battery life: Meter use 1000 hours; Insulation test use: Meter

Temperature coefficient: 0.05 x (specified accuracy) per °C           can perform at least 1000 insulation tests with fresh alkaline

for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F)              batteries at room temperature. These are standard tests of

Relative humidity, non-condensing: < °C                               1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25

0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F)                         seconds off

0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F)                        Size: 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in

0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F)                       W x 8.00 in L)

Vibration: Random, 2 g, 5-500 Hz per MIL-PRF-28800F,                  Weight: 550 g (1.2 lb)

Class 2 instrument                                                    IP rating: IP40

Shock: 1 meter drop per IEC 61010-1 2nd Edition (1 meter              Altitude (operating): 2000 m CAT III 1000 V, CAT IV 600 V;

drop test, six sides, oak floor)                                      3000 m CAT II 1000 V, CAT III 600 V

Electromagnetic compatibility: In an RF field of 3 V/M,               Storage: 12,000 m

accuracy = specified accuracy except in temperature:                  Over-range capability: 110 % of range except for

accuracy = specified accuracy ± 5 °C (9 °F). (EN 61326-1:1997)        capacitance which is 1 %

Safety: Complies with ANSI/ISA 82.02.01 (61010-1) 2004,               Compliance to EN 61557: IEC61557-1, IEC61557-2

CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd

Edition for measurement CAT III 1000 V and CAT IV 600 V

                                                                                         1587/1577 Insulation Multimeters  Fluke Corporation  5
            Comparison Chart

                                                                                    1587  1577

   Insulation test voltages 50 V, 100 V, 250  V,  500    V,  1000  V                •

   Insulation test voltages 500 V, 1000 V                                                 •

   Insulation test: 0.01 MΩ to 2.0 GΩ                                               •

   Insulation test: 0.1 MΩ to 600 MΩ                                                      •

   Auto-discharge of capacitive voltage                                             •     •

   Insulation test smoothing reading                                                •

   Frequency                                                                        •

   Capacitance                                                                      •

   Diode test                                                                       •

   Temperature                                                                      •

   Min/Max                                                                          •

   Low pass filter (for work on VSDs)                                               •

   AC/DC Voltage                                                                    •     •

   DC Millivolts                                                                    •     •

   AC/DC milliAmps                                                                  •     •

   Resistance (0.1 Ω to 50 MΩ)                                                      •     •

   Continuity                                                                       •     •

   Three-year warranty                                                              •     •

   Remote probe, test leads, alligator clips                                        •     •

   K-type thermocouple                                                              •

   Rugged, utility hard case                                                        •     •

   Auto power off                                                                   •     •

   Ordering Information

Fluke-1577            Insulation

                      Multimeter

Fluke-1587            Insulation

                      Multimeter

Included

Remote probe, test leads,

alligator clips, K-type thermo-

couple (1587 only), hard case,

user documentation

Optional accessories                          1577                                        1587

TPAK        Magnetic Tool Hanger

i400s       Clamp with Adapter                                                                  Fluke. Keeping your world

C25         Soft Case                                                                           up and running.

                                                                                                Fluke Corporation

                                                                                                PO Box 9090, Everett, WA USA 98206

                                                                                                Fluke Europe B.V.

                                                                                                PO Box 1186, 5602 BD

                                                                                                Eindhoven, The Netherlands

                                                                                                For more information call:

                                                                                                In the U.S.A. (800) 443-5853 or

                                                                                                Fax (425) 446-5116

   TPAK                       i400s                          C25                                In Europe/M-East/Africa (31 40) 2 675 200 or

                                                                                                Fax (31 40) 2 675 222

                                                                                                In Canada (800)-36-FLUKE or

                                                                                                Fax (905) 890-6866

                                                                                                From other countries +1 (425) 446-5500 or

                                         For additional accessories for these products,         Fax +1 (425) 446-5116

                                         see the Top 10 Accessories for Insulation              Web access: http://www.fluke.com/

                                         Multimeters at www.fluke.com/top10 or

                                         ask for Fluke literature code 2427793.                 ©2002 Fluke Corporation. All rights reserved.

                                                                                                Printed in U.S.A.  9/2005  2434792 D-US-N Rev C

6  Fluke Corporation   1587/1577 Insulation Multimeters
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Fluke:

FLUKE-1587-MDT  1577    1587  FLUKE-1587 W/NIST CERT W/O DATA

小广播

1577器件购买:

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved