Relay Sockets & Hardware SOCKET MM3XP & MM4XP

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Omron
产品种类:
Product Category:
Relay Sockets & Hardware
RoHS:YES
产品:
Product:
Relay Sockets
Accessory Type:Mounting Socket
Associated Relay Series:61F
端接类型:
Termination Style:
Screw
高度:
Height:
31 mm
系列:
Series:
61 F
宽度:
Width:
72 mm
商标:
Brand:
Omron Automation and Safety
安装风格:
Mounting Style:
DIN Rail
产品类型:
Product Type:
Relay Sockets & Hardware
工厂包装数量:
Factory Pack Quantity:
20
子类别:
Subcategory:
Relays

14PFA器件文档内容

    Voltage Sensor

    SDV

                                                                                         CSM_SDV_DS_E_6_3

Overvoltage/Undervoltage Monitoring

Relay for AC and DC Input

• Detect overvoltages or undervoltages (switch select-

able) from 4 mV to 300 V.

• Detect undercurrent, reverse current, or overcurrent in

DC circuits using shunt (SDV-FL).

• Detect three-phase AC current for under and/or overcur-

rent using current converter.

• Available in 7 supply voltage configurations.

• Single-function model with ON-delay, OFF-delay, or star-

tup lock settings (SDV-FH@T).

• Select either AC or DC voltage input.                                     For the most recent information on models that have been certified for

                                                                            safety standards, refer to your OMRON website.

• Polarity can be specified (SDV-FL) to enable easy re-

verse current detection.

• Selectable reset value range from 2% to 30% of operat-

ing value (SDV-F).

• LED operation indicator.

• UL/CSA approval (SDV-F@).

Model Number Structure

■ Model Number Legend

SDV-@@@@@

    1    2  3  4  5  6

1.  Voltage Sensor                                                   Note:  Not possible for the SDV equipped with the timing function

2.  Operation                                                               (SDV-FH@T).

    F:   Single-function (overvoltage or undervoltage detection)

    D:   Dual-function (overvoltage and undervoltage detection)

3.  Operating Voltage Range

    L:   4 to 240 mV (DC input only) (For SDV-F only)

    M:   0.2 to 12 V (AC or DC input)

    H:   10 to 300 V (AC or DC input)

4,  5. Control Power Supply Voltage

    2:   24 VDC

    3:   48 VDC

    4:   100/110 VDC

    5:   125 VDC

    51:  200/220 VDC (Single-function models)

    6:   100/110 VAC

    61:  120 VAC (Single-function models)

    7:   200/220 VAC

    71:  240 VAC (Single-function models)

6.  Timing Function (SDV-FH Only (See Note))

    None: Not provided

    T:   Provided

Note: SDV-FL and SDV-FM models can also be equipped with the

         timing function as a special specification. Ask your OMRON

         representative for details.

                                                                                                                                                    1
                                                                                                                                                 SDV

SDV-SH @@@@ (Order Separately)

    1        2  3    4  5

1.  Shunt (For SDV-FL Only)

2, 3, 4, 5. Rated Current

Available Models

      Rated current          Rated voltage           Model                           Rated  current             Rated  voltage                Model

5A                         60 mV            SDV-SH5                     75 A                              60 mV                    SDV-SH75

7.5 A                                       SDV-SH7.5                   100 A                                                      SDV-SH100

7.5 A                      100 mV           SDV-SH7.5 100MV             150 A                                                      SDV-SH150

10 A                       60 mV            SDV-SH10                    200 A                                                      SDV-SH200

15 A                                        SDV-SH15                    300 A                                                      SDV-SH300

20 A                                        SDV-SH20                    500 A                                                      SDV-SH500

30 A                                        SDV-SH30                    750 A                                                      SDV-SH750

50 A                                        SDV-SH50                    1,000 A                                                    SDV-SH1000

Note: All the above listed shunts have an accuracy in the 1.0 class.

Connecting Socket (Order Separately)

             Applicable models                                                                       Socket

                                                                        Type                                                    Model

SDV-F@@/-FH@T                               Front Connecting Socket                                       8PFA1

                                            Back Connecting Socket                                        PL08

SDV-D@@                                     Front Connecting Socket                                       14PFA

                                            Back Connecting Socket                                        PL15

Ordering Information

Single-function Models

Overvoltage or Undervoltage Detection                    (Switch Selectable)

    Control power supply voltage                                                            Input

                                            DC                                                            DC or  AC  (selectable)

                                                                                     Input voltage     range

                                            4 to 240 mV                                     0.2 to 12  V                           10 to 300  V

24 VDC                             SDV-FL2                              SDV-FM2                                        SDV-FH2

48 VDC                             SDV-FL3                              SDV-FM3                                        SDV-FH3

100/110 VDC                        SDV-FL4                              SDV-FM4                                        SDV-FH4

125 VDC                            SDV-FL5                              SDV-FM5                                        SDV-FH5

200/220 VDC                        ---                                  ---                                            SDV-FH51

100/110 VAC                        SDV-FL6                              SDV-FM6                                        SDV-FH6

120 VAC                            ---                                  ---                                            SDV-FH61

200/220 VAC                        SDV-FL7                              SDV-FM7                                        SDV-FH7

240 VAC                            ---                                  ---                                            SDV-FH71

Dual-function Models

Overvoltage and Undervoltage Detection

           Control power supply voltage                                              Input: DC or AC (selectable)

                                                                                            Input voltage range

                                                                        0.2 to 12 V                                    10 to       300 V

24 VDC                                      SDV-DM2                                                       SDV-DH2

48 VDC                                      SDV-DM3                                                       SDV-DH3

100/110 VDC                                 SDV-DM4                                                       SDV-DH4

125 VDC                                     SDV-DM5                                                       SDV-DH5

100/110 VAC                                 SDV-DM6                                                       SDV-DH6

200/220 VAC                                 SDV-DM7                                                       SDV-DH7

240 VAC                                     SDV-DM71                                                      SDV-DH71

Note: 1.   Inquire about production of models with 120- and 240-VAC control power supply.

       2.  Inquire about models with special processing for high-temperature, high-humidity applications.

       3.  The ripple factor must be 5% or less for DC power supplies.

                                                                                                                                                      2
                                                                                                                                                SDV

Single-function Models with Timing Function

Control power  supply      voltage                            Input:  DC    or  AC  (selectable); input voltage  range:  10  to  300 V

                                                                                       Operating mode

                                                   ON-delay                            OFF-delay                                 Startup  lock

24 VDC                              SDV-FH2T

48 VDC                              SDV-FH3T

100/110 VDC                         SDV-FH4T

125 VDC                             SDV-FH5T

200/220 VDC                         SDV-FH51T

100/110 VAC                         SDV-FH6T

120 VAC                             SDV-FH61T

200/220 VAC                         SDV-FH7T

240 VAC                             SDV-FH71T

Note: Only SDV-FH voltage sensors can be manufactured with a timer.

Specifications

Single-function Models

Overvoltage or Undervoltage Detection (Switch Selectable)

Model          Input voltage        Selectable operating range                   Selectable reset   value  range             Control power supply

SDV-FL@      DC                     4 to 240 mV                                 2% to 30% (related  to              24, 48, 100/110, 125, 200/220 VDC

                                    (4 to 12 mV, 10 to 30 mV,                   operating value)                    (see note);

                                    20 to 60 mV, 40 to 120 mV,                                                      100/110, 200/220/240 VAC

                                    80 to 240 mV)                                                                   (50/60 Hz)

SDV-FM@      DC or AC               0.2 to 12 V

             (selectable)           (0.2 to 0.6 V, 0.5 to 1.5 V, 1 to 3 V,

                                    2 to 6 V, 4 to 12 V)

SDV-FH@                             10 to 300 V

SDV-FH@T                            (10 to 30 V, 25 to 75 V, 50 to 150 V,

                                    100 to 300 V)

Note: Ripple is 5% max. with DC power supplies.

Dual-function Models

Overvoltage and Undervoltage Detection

Model        Input voltage                 Selectable operating       range                       Reset value                Control power supply

                                    Intermediate voltage of                 Dead band

                                           dead band                        voltage

SDV-DM@      DC or AC         0.2 to 12 V          0.2 to 0.6 V       0.02 to 0.1 V    Overvoltage:                 24, 48, 100/110, 125 VDC;

             (selectable)                          0.5 to 1.5 V       0.05 to 0.25 V   (Intermediate voltage of     100/110, 200/220/240 VAC

                                                   1 to 3 V           0.1 to 0.5 V     dead band + dead band        (50/60 Hz)

                                                                                       voltage) – (dead band volt-

                                                   2 to 6 V           0.2 to 1 V       age x 2/3) min.

                                                   4 to 12 V          0.4 to 2 V       Undervoltage:

SDV-DH@                       10 to 300 V          10 to 30 V         1 to 5 V         (Intermediate voltage of

                                                   25 to 75 V         2.5 to 12.5 V    dead band – dead band

                                                                                       voltage) + (dead band volt-

                                                   50 to 150 V        5 to 25 V        age x 2/3) max.

                                                   100 to 300 V       10 to 50 V

Note: 1.  Inquire about production of models with 120- and 240-VAC control power supply.

2.        The ripple factor must be 5% or less for DC power supplies.

                                                                                                                                                       3
                                                                                                                                        SDV

■ Ratings

            Item                 SDV-FL@                SDV-FM@              SDV-FH@/FH@T          SDV-DM@                    SDV-DH@

Allowable continuous      ±10 VDC                ±150 VDC            ±350 VDC                ±150 VDC             ±350 VDC

input overvoltage range                          150 VAC             (±500 VDC for 1 min)    150 VAC              (±500 VDC for 1 min)

                                                                     350 VAC                                      350 VAC

                                                                     (500 VAC for 1 min)                          (500 VAC for 1 min)

Input impedance           1 kΩ                   50 kΩ               2,500 kΩ                50 kΩ                2,500 kΩ

Control output            SPDT                                                               SPST-NO and SPST-NC

                          Rated load: 5 A at 220 VAC (cosφ = 1),

                                   5 A at 24 VDC (cosφ = 1),

                                   2 A at 220 VAC (cosφ = 0.4),

                                   2 A at 24 VDC (L/R = 7 ms)

                          Max. contact voltage:      250 VAC, 125 VDC

                          Max. contact current:      5A

                          Max. switching capacity: 1,100 VA (cosφ = 1), 120 W (cosφ = 1),

                                                     440 VA (cosφ = 0.4), 48 W (L/R = 7 ms)

Power consumption         DC: 5 W max.; AC: 5 VA max.

Ambient temperature       –10 to 55°C (with no icing)

Control supply voltage    24, 48, 100/110, 125, 200/220 VDC; DC operating voltage range: 80% to 130% of control power supply

(see note)                100/110/120, 200/220/240 VAC (50/60 Hz); AC operating voltage range: 85% to 110% of control power supply

Note: The impedance value is a reference value; actual values may vary.

■ Characteristics

               Item                          SDV-F@@                          SDV-FH@T                            SDV-D@@

Operating value                  100% operation for voltage setting

Setting error                    Operating value: ±2% of operating value                           ±2% of intermediate voltage of dead  band,

                                 (This is the ratio for the setting value.)                        ±1% of dead band voltage

                                 Reset value: ±7% of reset value

                                 (This is the ratio for the setting value.)

Operating time                   0.5 s max. (see note)

Influence of temperature         0 to 40°C:                                                        0 to 40°C:

                                 ±2% max. of operating value                                       ±2% max. of dead band voltage

                                 (SDV-FL (operating value range: 4 to 12 mV)                       –10 to 0°C, 40 to 55°C:

                                 ±4% max. of operating value)                                      ±4% max. of dead band voltage

                                 –10 to 0°C, 40 to 55°C:

                                 ±4% max. of operating value

                                 (SDV-FL (operating value range: 4 to 12 mV)

                                 ±8% max. of operating value)

Influence of control power       ±1% max. of operating value                                       ±1% max. of dead band voltage

                                 DC operating voltage range: 80% to 130%                           DC operating voltage range: 80% to 130%

                                 AC operating voltage range: 85% to 110%                           AC operating voltage range: 85% to 110%

Influence of frequency           ±1% max. of operating value                                       ±1% max. of dead band voltage

(Input frequency changed

from 10 to 500 Hz for AC in-

put)

Influence of waveform            ±3% max. of operating value                                       ±3% max. of dead band voltage

(For commercial frequency,

single-phase, full-wave AC

input)

Insulation resistance            10 MΩ min. (at 500 VDC) between the entire electric circuitry and external case, and between the input terminal

                                 and power terminal

Dielectric strength              2,000 VAC for 1 min between the entire electric circuitry and external case, and between the input terminal and

                                 power terminal

Impulse withstand voltage        ±1.2 x 50 μs, 4,500 V between the entire electric circuitry and external case

                                 ±1.2 x 50 μs, 3,000 V between power terminals

Vibration resistance             Destruction:   10 to 25 Hz, 2-mm double amplitude (2G max.) for 2 hrs each in 3 directions

                                 Malfunction:   16.7 Hz, 1-mm double amplitude for 10 min each in 3 directions

Shock resistance                 Destruction:   294 m/s2 (30G)

                                 Malfunction:   98 m/s2 (10G)

Weight                           Approx. 290 g                       Approx. 350 g                 Approx. 310 g

Note: Overvoltage:    Operation  when voltage is changed from 80% to 120% of the operating value.

      Undervoltage:   Operation  when voltage is changed from 120% to 80% of the operating value.

                                                                                                                                                  4
                                                                                                                                                                        SDV

Timing Function

                 Item                                                                                       SDV-FH@T

Setting time                                               0.5 to 30.0 s (see note)

Operating time accuracy                                    ±5% FS max.

Setting error                                              ±15% FS max.

Reset time                                                 5 s min.

Influence of temperature                                   ±10% FS max.

Operating mode (set via DIP switch)                        ON-delay, OFF-delay, Startup lock

Note: The time setting range when the                      startup lock is selected for the operating mode  is approximately  1  to  30  s.

Nomenclature

SDV-F@/-FH@T                                                                                     SDV-D@

           Operation Indicator (LED)

The diagram on                                                              Setting Operating    Setting Intermediate

                                                                            Value                Voltage of Dead Band                                                   Setting Dead

the right shows  Function Sticker                                                                                                                                       Band Voltage

the SDV-FH6T

when used for    Voltage Multiplying

undervoltage     Factor Sticker

detection for

DC input.                                                                   Setting Reset Value  Operation Indicator

               Location of DIP switch to

               set operating modes                                                                                     Function Sticker            Voltage Multiplying

                                                                                                                       Location of DIP switch to   Factor Sticker

                                                           Setting          Operating Time                             set operating modes

                                                                                                                       The diagram above shows the

                 Note: The                SDV-F@  is  not  equipped with a  time setting knob.                         SDV-DH3 when used for AC input

                                                                                                                       in the range 100 to 300 V.

                                                                                                                                                                                      5
                                                                                                                                               SDV

Operation

■ Timing Charts

Single-function Models

Overvoltage Detection                            Undervoltage Detection

                     Input

Operating                                                           Input

value                                            Operating                                      Reset value

                                   Reset value   value

Output relay  ON

              OFF                                              ON

                                                 Output relay  OFF

Note

The reset time must be 5 s or longer to ensure accuracy of the timing operation.

Single-function Model with Timing Function

SDV-FH@T

ON-delay Overvoltage Detection

                     Input                                                                      Input

Operating                                                                         Operating

value                                                               Reset value   value                                          Reset value

                                                                                                                   Setting time

                                                                                  Output relay

              ON

Output relay OFF                                                                                       Reset time

                                                                                                       (5 s min.)

                     Setting time  Setting time  Setting time

ON-delay Undervoltage Detection

              Input

                                                                                                Input

Operating                                                           Reset value   Operating                                      Reset  value

value                                                                             value

                                                                                                                   Setting  time

                                                                                  Output relay

              ON                                                                         ON

Output relay                                                                             OFF

              OFF

                                                                                                       Reset time

                     Setting time  Setting time  Setting time                                          (5 s min.)

                                                                                                                                                    6
                                                                                                                                                                  SDV

OFF-delay Overvoltage Detection

                     Input                                                                                                Input

Operating

value                                                                                  Reset  value  Operating                                       Reset value

                                                                                                     value

                                                                                                     Output relay                     Setting  time

                                                                                                                   ON

              ON                                                                                                   OFF

Output relay                                                                                                              Reset time

              OFF                                                                                                         (5 s min.)

                            Setting time             Setting time  Setting       time

OFF-delay Undervoltage Detection

              Input                                                                                                Input

                                                                                 Reset value                                                         Reset value

Operating                                                                                            Operating

value                                                                                                value

                                                                                                                                      Setting  time

              ON                                                                                     Output relay  ON

Output relay                                                                                                       OFF

              OFF

                                                                                                                          Reset time

                            Setting time      Setting time         Setting time                                           (5 s min.)

Startup Lock

              ON                                                                                                          ON

Power         OFF                                                                                                  Power  OFF

                                                                                                                                               Reset time

Output operation                                                                                                                               (5 s min.)

                            Setting time

Note: The output relays will be forced OFF from the control power supply is turned ON until the set time has expired.

Dual-function Models

SDV-D

                                              Input

                     H

Intermediate         Dead band voltage

voltage of           Dead band voltage

dead band            L

                                          ON  ON

                            Undervoltage      Overvoltage

                            relay             relay

                                                                                                                                                                       7
                                                                                                                                                          SDV

■ Setting

(Refer to Examples of Mode Settings for details on individual models.)

Set the desired values using the DIP switch and setting knobs on the front panel.

Opening the DIP Switch Cover

Remove the cover of the compartment containing the DIP switch for various mode              settings, and then set  the  DIP  switch  according  to  the  SWITCH

SELECTION table affixed to the side of the voltage sensor.

   Cover

Flat-blade                                                                                  Cover

screwdriver

                                                                                            Flat-blade screwdriver

Setting the DIP Switch

Set the DIP switch on the front panel for the required functions, operation inputs, and voltages. Set the switch to the       top     for  ON  settings  and  to  the

bottom for OFF settings.

•  Function (SDV-F): Set to either overvoltage or undervoltage detection.

•  Input: Set to either AC or DC input.

•  Polarity (SDV-FL@ only): Set polarity or not to specify polarity.

                          “8(+), 7(–)”: Use polarity as shown for pin number.

                          “FREE”:          Do not use polarity.

•  Multiplying Factor: Set the voltage scale multiplying factor for the required operating  voltage setting range.

•  TIMER (SDV-FH@T): Select the timing function.

   Set ON-delay, OFF-delay, lock timer (start lock timer), or TIMER OFF.

   If TIMER OFF is set, the timing function will not be effective, and the single-function  operation will be performed.

Setting of Time (SDV-FH@T Only)

Use the time setting knob to set the desired time.

Closing the DIP Switch Cover

Attach the cover to the compartment housing the DIP switch. Select the stickers for the settings that have been made and attach them to the cover.

Setting Flowchart

                                            Select model based on operation and type of input.

                     Single-function Model                                                         Dual-function Model

   Determine detection method, polarity setting, operating value,              Determine intermediate voltage of dead band and dead band

   and reset value.                                                            voltage.

                                                                               Determine reset value according to dead band voltage.

   Obtain the PICK UP index scale value, HOLD index scale                      Obtain the BALANCE index scale value, BAND WIDTH index

   value, and voltage multiplying factor.                                      scale value, and voltage multiplying factor.

   Set the knob and the DIP switch, and attach stickers.                       Set the knob and the DIP switch, and attach stickers.

   Set the desired operating mode for the SDV-FH@T.

                                                                                                                                                                       8
                                                                                                            SDV

SDV-FL@

Switch Selection Table

                                                                                  Accessory         Labels

Switch       ON      ●                1  2  3  4  5                   6

             OFF                                                                  OVER      ×4 mV

                                                                                  POL FREE

Function     Under               ●

             Over                                                                 OVER      ×10 mV

                                                                                  8 (+)

Polarity     8 (+) 7 (–)                 ●                                        POL7 (−)

             Free                                                                 UNDER     ×20 mV

                                                                                  POL FREE

Multiplying  x 4 mV              →                                                UNDER

factor       x 10 mV             →          ●                                     8 (+)     ×40 mV

                                                                                  POL7 (−)

             x 20 mV             →             ●

             x 40 mV             →                ●                                         ×80 mV

             x 80 mV             →                   ●

SDV-FM@

Switch Selection                 Table

                                                                                  Accessory         Labels

Switch       ON      ●                1  2  3  4  5                   6

             OFF                                                                  OVER      ×0.2 V

                                                                                  INPUT DC

Function     Under               ●

             Over                                                                 OVER      ×0.5 V

                                                                                  INPUT AC

Input        AC (20 to      500  Hz)     ●                                        UNDER

             DC                                                                   INPUT DC  ×1 V

Multiplying  x 0.2 V             →                                                UNDER     ×2 V

factor       x 0.5 V             →          ●                                     INPUT AC

             x1V                 →             ●                                            ×4 V

             x2V                 →                ●

             x4V                 →                   ●

SDV-FH@

Switch Selection Table

                                                                                  Accessory         Labels

Switch       ON      ●           1       2  3  4  5  6

             OFF                                                                  OVER      ×10 V

                                                                                  INPUT DC

Function     Under               ●

             Over                                                                 OVER      ×25 V

                                                                                  INPUT AC

Input        AC (20 to      500  Hz)     ●                            (see note)

             DC                                      NO USE                       UNDER     ×50 V

                                                                                  INPUT DC

Multiplying  x 10 V              →                                                UNDER

factor       x 25 V              →          ●                                     INPUT AC  ×100 V

             x 50 V              →             ●

             x 100 V             →                ●

Note: “NO USE” indicates that DIP switch setting is not required and

       the positions of these switches are irrelevant to the operation of

       the voltage sensor.

                                                                                                                 9
                                                                                                                                                                      SDV

SDV-FH@T

Switch Selection Table

Switch          ON      ●        1       2      3        4       5  6                   7    8            9  10                  Accessory             Labels

                OFF

Function        Under            ●                                                                                                       OVER  ×10 V

                                                                                                                                 INPUT DC

                Over                                                                                                                     OVER  ×25 V

Input           AC (20 to   500  Hz)     ●                                                                                       INPUT AC

                DC                                                  NO USE  (see note)                                           UNDER         ×50 V

Multiplying     x 10 V           →                                                                                               INPUT DC

factor          x 25 V           →              ●                                                            NO USE  (see note)  UNDER

                x 50 V           →                       ●                                                                       INPUT AC      ×100 V

                x 100 V          →                            ●

Timer                            ON-delay                           →                   ●    ●          ●

                                 OFF-delay                          →                   ●    ●

                                 Lock timer                         →                                   ●

                                 Timer OFF                          →

Note: “NO USE” indicates that DIP switch     setting  is not  required and              the  positions  of   these   switches    are irrelevant to the operation  of  the voltage

       sensor.

SDV-DM@

Switch Selection Table

                                                                                             Accessory                           Labels

Switch          ON      ●             1      2        3       4        5

                OFF                                                                             OVER&        ×0.2 V

                                                                                                UNDER

Input           AC (20 to                                                                       INPUT DC

                500 Hz)               ●                                                         OVER&        ×0.5 V

                                                                                                UNDER

                DC                                                                              INPUT AC

Multiplying     x 0.2 V          →                                                                           ×1 V

factor          x 0.5 V          →           ●

                x1V              →                 ●                                                         ×2 V

                x2V              →                            ●

                x4V              →                                  ●                                        ×4 V

SDV-DH@

Switch Selection Table

                                                                                             Accessory                           Labels

Switch          ON      ●             1      2        3       4        5

                OFF                                                                             OVER&        ×10 V

                                                                                                UNDER

Input           AC (20 to                                                                       INPUT DC

                500 Hz)               ●                                                         OVER&        ×25 V

                                                                                                UNDER

                DC                                                          (see note)          INPUT AC

Multiplying     x 10 V           →                                  NO USE                                   ×50 V

factor          x 25 V           →           ●

                x 50 V           →                 ●                                                         ×100 V

                x 100 V          →                            ●

Note: “NO USE” indicates that DIP switch setting is not required and

       the positions of these switches are irrelevant to the operation of

       the voltage sensor.

                                                                                                                                                                                   10
                                                                                                                  SDV

■ Examples of Mode Setting

Example 1

For the single-function SDV-FH6, the setting method given below would be used to detect overvol-

tages with a DC voltage input. The operating value is 15 V and the reset value is 12 V.

Step 1.  To set the detection method and type of input on the DIP switch.

         Turn OFF pin 1 (function) to specify overvoltage detection.                                    SDV-F@@

         Turn OFF pin 2 (input) to specify a DC input.

         Attach the OVER INPUT DC stickers.

Step 2. To set the operating value according to the voltage multiplying factor and the PICK UP

         index scale value.

Voltage multiplying factor setting: The voltage multiplying factor is selected according to the

maximum and minimum factors and a sticker is attached.

The calculation method is as follows:

         The PICK UP index scale value is between 1.0 and 3.0, so calculate the voltage multiplying

         factor for both 1.0 and 3.0.

         15 V (Operating value)/1 (PICK UP index scale value) = 15 (Maximum multiplying factor)

         15 V (Operating value)/3 (PICK UP index scale value) = 5 (Minimum multiplying factor)

         In this example, pins 3 to 5 are turned OFF and the x10V sticker is attached.

         PICK UP index scale value setting: The calculation method is as follows (X = index scale):

         10 (Voltage multiplying factor) x X = 15 V (Operating value)

         Therefore, X = 1.5

         Turn the PICK UP knob to 1.5.

Step 3. To set the reset value (Y = HOLD index scale value): Calculate the HOLD percentage as

         follows:

         12 V (reset value) = 15 V (operating value) x (1 − Y)        Therefore, Y = 0.2

Set the HOLD knob to 20 (%).

Example 2

For the single-function SDV-FH6T, the setting method given below would be used to detect undervol-

tages with a DC voltage input. The operating value is 20 V and the reset value is 20.4 V. An ON-delay

operation is specified and the setting time is 30 s.

Step 1.  To set the detection method and type of input on the DIP switch.                               SDV-FH@T

         Turn ON pin 1 (function) to specify undervoltage detection.

         Turn OFF pin 2 (input) to specify a DC input.

         Attach the UNDER INPUT DC stickers.

Step 2.  To set the operating value according to the voltage multiplying factor and the PICK UP

         index scale value.

         Voltage multiplying factor setting: The multiplying factor is selected according to the maxi-

         mum and minimum factors and a sticker is attached. The calculation method is as follows:

         The PICK UP index scale value is between 1.0 and 3.0, so calculate the voltage multiplying

         factor for both 1.0 and 3.0.

         20 V (Operating value)/1 (PICK UP index scale value) = 20 (Maximum multiplying factor)

         20 V (Operating value)/3 (PICK UP index scale value) = 6.7 (Minimum multiplying factor)

         In this example, pins 3 to 5 are turned OFF and the x10V sticker is attached.

         PICK UP index scale value setting: The calculation method is as follows (X = index scale):

         10 (Voltage multiplying factor) x X = 20 V (Operating value)

         Therefore, X = 2

         Turn the PICK UP knob to 2.0.

Step 3.  To set the reset value (Y = HOLD index scale value): Calculate the HOLD percentage as

         follows:

         20.4 V (reset value) = 20 V (operating value) x (1 + Y)       Therefore, Y = 0.02

         Set the HOLD knob to 2 (%).

Step 4.  To set setting time and operating mode.

         Set the time setting knob to 30 s and turn the pins 7 to 9 ON to specify ON-delay operation.

                                                                                                                  11
                                                                                                                              SDV

Example 3

For the dual-function SDV-DH3, the setting method given below would be used to detect over and

undervoltage with an AC voltage input. The intermediate voltage of dead band is 250 V and the dead

band voltage is 20 V.

Step 1.   To set the detection method and type of input on the DIP switch.

          Turn ON pin 1 (input) to specify a AC input.                                                     SDV-D@@

          Attach the OVER and UNDER INPUT AC stickers.

Step  2.  To set the intermediate voltage of dead band according to the BALANCE index scale

          value and the voltage multiplying factor.

          Voltage multiplying factor setting: The voltage multiplying factor is selected according to the

          maximum and minimum factors and a sticker is attached. The calculation method is as fol-

          lows:

          The BALANCE index scale value is between 1.0 and 3.0, so calculate the voltage multiply-

          ing factor for both 1.0 and 3.0.

          250 V (Intermediate voltage of dead band)/1 (BALANCE index scale value)

          = 250 (maximum multiplying factor)

          250 V (Intermediate voltage of dead band)/3 (BALANCE index scale value)

          = 83.3 (maximum multiplying factor)

          In this example, pins 2 and 3 are turned OFF and pins 4 is turned ON, and the x100V sticker

          is attached.

          BALANCE index scale value setting: The calculation method is as follows for the BALANCE

          index scale value (X = index scale):

          100 (Voltage multiplying factor) x X = 250 V (intermediate voltage of dead band)

          Therefore, X = 2.5

          Turn the BALANCE knob to 2.5.

Step  3.  To set dead band voltage according to the voltage multiplying factor and BAND WIDTH

          index scale value.

          BAND WIDTH index scale value setting:

          Z (BAND WIDTH index scale value) x 100 V (voltage multiplying factor) = 20 V (dead band

          voltage)     Therefore, Z = 0.2

          Set the DEAD WIDTH knob to 0.2.

Step 4.   Reset value for each detection setting: Automatically set according to the dead band

          voltage setting.

          Reset values are calculated for overvoltage detection and undervoltage detection.

          Overvoltage detection: Reset value = (250 V + 20 V) − (20 V x 2/3) = 256.7 min.

          Undervoltage detection: Reset value = (250 V − 20 V) + (20 V x 2/3) = 243.3 max.

■ Shunts (Order Separately)                                                 Characteristics

                                                                            SDV-SH5A (Rated Current: 5 A)

A shunt is a resistor to convert a DC current into a DC voltage. Use        (mV)

the shunt in combination with SDV-FL to detect undercurrent, reverse

current and overcurrent in DC circuits.

Note: Select a shunt whose rated current is more than 120% of the           Output voltage

      current normally flowing in a circuit. The characteristics of the                                    Shunt rated

      shunt may change or fusing of a resistor element may occur if                                        at 60 mV

      an overload that is 1,000% of the rated current is applied.

      Therefore, determine the rated current of the shunt to be used,                       60

      by taking the circuit conditions into account.

                                                                                                5          Input current (A)

                                                                                                                                   12
                                                                                                                                                          SDV

■ Application Example

Current Detection Using the                                              Shunt (SDV-FL)

Overload Detection (A)                                                              Overload Detection (B)

                                                                                    (+) (−)

DC power                              Distribution  switchboard                                                 SDV-SH

supply for               SDV-SH                                             Power   or                          shunt      M_

distribution             shunt                                              supply

board

                                                                                    (−) (+)                                DC motor

                         (−)

                                      SDV-FL                                                                            SDV-FL

                      (+)             (with or without polarity)                                                        (without polarity)

Example:      Overload detection in a distribution switch                           Example:  Overload detection in equipment such as a motor in a

              board installed in a power substation.                                          rolling mill when the polarity of the applied voltage to

                                                                                              the motor is reversed.

Reverse Current Detection (A)                                                       Reverse Current Detection (B)

                                                                                                     4 to 20mA

DC power                 SDV-SH                     M_                              Power supply                           Transmitter

                         shunt                                                      for transmitter

supply                                                                                        10 Ω or more

                                      DC motor

                                                                                                                        Quantity of

                                                                                                                        low, airflow,

                                                                                                                        wattage, etc.

                                                                                                       (+)

                         (+)

                                                                                                                        SDV-FL

                                      SDV-FL                                                           (−)              (with or without polarity)

                         (−)          (with polarity)

                                                                            Example:          Detection of an output current from a transmitter      on

Example:      Detection when a DC motor is used                                               a control panel.

              as a generator (or a generator is

              used as a motor).

Voltage Detection (SDV-FM/FH/FH@T/-DM/-DH)

Voltage Regulation                                                                  Operation Lock Due to Voltage Drop (Alarm)

3 dia.

              Thyristor                                          Distribu-                                                 Machine

              power                                              tion                                                      or equip-

              supply                                             switch                                                    ment

                                                                 board

                                                                                                                                        Command

                                                                                                                                        signal for

          Command                (+)                                                                                                    operation

          signal for                                                                                                                    lock

          regulation                                                                                                       SDV-FH/SDV-FH@T

                                                                                                                           with ON-delay operation

            SDV-DH               (−)                                                                                       (undervoltage detection)

Example:      Voltage regulation of a power supply unit in the dis-                          Example:  Function lock due to voltage drop in a machine or

              tribution switchboard installed in a power substation.                                   equipment (alarm).

                                                                                                                                                          13
                                                                                                                                           SDV

Emergency  Power Supply       (e.g. Standard         Power    Receiving/Distributing Facility)

                              Non-utility generator

                              Engine                 G

                                                                            Voltage regula-

                                                                            tion (rotation

                                                                            control)

           Detection of

           power failure

                                                     Exciter  SDV-DH

                              Drive command

                              (Starts/Stop)

           SDV-FH (undervol-

           tage detection)

                                                              Power supply

                                                                                                    Detection of power failure or trans-

                                                                                                    former trouble (for the DC lighting

                                                                                                    command in emergency illumination)

                                                                                                    SDV-FH (undervoltage

                                                                                                    detection)

                                                                                                                   Detection of battery

                                                                                                                   overdischarge

                                                                                                                SDV-FH/SDV-FH@T

                                                                                                                with ON-delay operation

                                                                                                                (undervoltage detection)

                                                                            Distribution board for general illumination

                                                                                                    Detection of partial power

                                                                                                    failure (for the lighting

                                                                                                    command in emergency

                                                                                                    illumination)

                                                                                                    SDV-FH (undervoltage

                                                                                                    detection)

                                                                            Distribution board for                 Emergency illumination

                                                                            emergency illumination                 output

                                                                                                                                                14
                                                                                                                                   SDV

Three-phase AC Current Detection Using Current Converter

                          SET Current Converter

                                                 SDV-DH

                                                 SDV-FH

                                                 SDV-FH@T

                                                 SDV-FM

Example:  Machine motor control, overload detection,

          undercurrent detection.

Current Converters (Order Separately)

        Model                      Current range

SET-3A                    1 to 80 A

SET-3B                    64 to 160 A

Three-phase AC Current Detection with Startup Lock Operation

(When Using Same Power Supply for Motor and Control Power Supply)

                          SET Current Converter

                                                                               Control power supply

                                                 SDV-FH@T

Voltage Monitoring in Rectifiers (Chargers) with ON-delay Operation

Example: To detect only overvoltage and not detect voltages for instantaneous load changes (ON/OFF).

               Rectifier

                                                                                                     Load  Load

                                                                                                           SDV-FH@T

                                                                                                           overvoltage detection

                                                                                                           SDV-FH@T

Note: Detection of excessive or insufficient charge in rectifiers (chargers).                              undervoltage detection

                                                                                                                                   15
                                                                                                  SDV

■   Q&A

Q:  What is necessary to detect undervoltages when using the same power supply for the input voltage and the control

    power supply?

                                    Load

    SDV-F (undervoltage detection)

A:  The NO contact of the output relay is used for undervoltage detection. Even if the control voltage drops to 85% of

    the rated voltage (AC power), the operation of the relay can be maintained. Set the mode setting on the DIP switch

    to overvoltage detection and set the reset value to the value to be detected. Set the operating value of the SDV to

    a value higher than the reset value.

Q:  Will the SDV be damaged if the input setting (AC/DC) is incorrect. If not, what will happen?

A:  The SDV will not be damaged, but the operating value and reset value will not be accurate. These values will be

    about 10% less than the set values if DC is input for an AC setting and about 10% off to the positive side if AC is

    input for a DC setting.

Q:  Can the negative pole of a DC voltage be input to the SDV?

A:  Yes. An absolute rectifier circuit is used in the SDV-F to enable negative pole input. The SDV-FL has a polarity

    setting, which can be set to (+)(–) to disable operation with negative voltages. Positive/Negative settings cannot

    be used for the dual-function SDV-D even if the intermediate voltage of dead band is set to 0. Negative inputs can-

    not be used for the SDV-D.

Q:  Is instantaneous detection faster than 0.5 s possible?

A:  Use the S87A Power Interruption Detector for instantaneous detection (10 ms or 20 ms).

                                                                                                                         16
                                                                                                                                                                  SDV

Dimensions

Note: All units are in millimeters unless otherwise indicated.

■ Main Body

SDV-F@@/SDV-FH@T

                                             3.5                                                                     Connecting Socket

                                                                     5

                               91  72                                                                                       SDV-F

                                                                                                                     119

                                                                                                                                                100        SDV-F

                                                      60                                       7                     8PFA1 (order separately)   16

                                                                                    89            8.5                                               PL08  (order separately)

                                                                           100

SDV-D@@

                                                 3.5

                                                                        5

                               79  60                                                                                           SDV-D

                                                                                                                     128.5

                                                                                                                                                    100    SDV-D

                                                          72                                      7

                                                                                        89             8.5

                                                                                    100                              14PFA  (order separately)  16

                                                                                                                                                     PL15  (order separately)

■ Shunts

SDV-SH5 to SDV-SH50 (60-mV Rating)                            SDV-SH75 to SDV-SH200 (60-mV Rating)

             140                                                           A

             120                                                           B

                                             25                                                        C

                                                                                                  D

                                       10.5 dia.

33                                                            G                                             E

                                             6    18                                                           F

                                       5.5                                                        5.5

                                       dia.                                                       dia.

    Current  terminal:     M6  screw                             Current terminal:      M8 screw

    Voltage  terminal:  M4     screw                             Voltage terminal:      M4 screw

    Model               A                         B                     C                   D                     E                F                       G

SDV-SH75     140                       120                       25        10.5                        6                    18                      36

SDV-SH100    140                       120                       25        10.5                        6                    18                      36

SDV-SH150    140                       120                       25        10.5                        6                    18                      43

SDV-SH200    140                       120                       25        10.5                        6                    18                      43

                                                                                                                                                                               17
                                                                                                                                                   SDV

SDV-SH300/-SH500 (60-mV Rating)                                                  SDV-SH750/-SH1000 (60-mV Rating)

            A                                                                                 A

                                  B                                                                        B

            C

                                                                                              C                5

                                     E

                                                                                                           D   E

                                  D

Current terminal:  M10 screw (SDV-SH300),                                              Current terminal:   M12 screw

                   M12 screw (SDV-SH500)                                               Voltage terminal:   M5 screw

Voltage terminal:  M4 screw                                                            Model          A        B           C                    D      E

Model  A               B     C          D                E      Resistor         SDV-            175       45         130      15                  30

SDV-   130         30        110     4          36           4                   SH750

SH300                                                                            SDV-            175       60         135      18                  30

SDV-   160         40        120     6          41           5                   SH1000

SH500

Note: Inquire about models with a rated current of 1,500 A or larger.

■ Accessories (Order Separately)

Front Connecting Socket

8PFA1

                                                                                                               Terminal Arrangement

                                        Eight, M3.5 x 7                                                        (Top View)

                                        sems

                                                                Two, 4.5-dia.

                                                                holes

                                     93 max.                                                  130 max.

                                                                                                               Mounting Holes

                                                                                                                     Two, M4 or 4.5-dia. holes

                                                51  max.

                                                                                 24 max.

14PFA

                                                                                                               Terminal Arrangement

                                     Fourteen,                                                                 (Top View)

                                     M3.5 x 7 sems

                                                                       Two,

                                                                       4.5-dia.

                                                                       holes

                                     81 max.                                                     118 max.

                                                                                                               Mounting Holes

                                                                                                                      Two, M4 or 4.5-dia. holes

                                                    72 max.

                                                                                 33.5  max.

                                                                                                                                                          18
                                                                                                                                                                                  SDV

Back     Connecting                Socket             (Solder Terminal)

PL08

                                                                                                                 Terminal Arrangement                  Mounting Holes

                                                                                                                 (Bottom View)

                                                                                    Two, 2-dia. holes

                     50.5  max.                                 30 dia.                                                                                Two, 3.5-dia. or

                                                                                                                                                       two, M3 socket

                                                                                                                                                       mounting holes

                                                                                                                                                               31-dia.

                                       35 max.                                                                                                                 hole

                                                                         Approx. 20.5

PL15

                                                                                                                     Terminal Arrangement

                                                                                                                     (Bottom View)

                                                                                        Two,  2-dia.  holes

                     66 max.                                     41 max.

                                             45 max.                          22  max.                               Mounting Holes

                                                                                                                     Two, M3 or two, 3.5-dia.

                                                                                                                     voltage sensor mounting

                                                                                                                     holes

                                                                                                       Two, M3 or Two, 3.5-dia.

                                                                                                       socket mounting holes

                                                                                                                                 42-dia. hole

Mounting Track

PFP-100N

PFP-50N                                                                                 PFP-100N2

                                                                                                                                                                         16

                                                      7.3+0.15

4.5                                                                                     4.5

                                                         35+0.3  27+0.15                                                                         35+0.3    27  24            29.2

     15  25      25                25      25                    1                            15       25        25              25      25  15                1             1.5

             10      1,000 (500)*      10             15 (5)*                                                10      1,000           10

                                             *PFP-50N

End Plates                                                                                    Spacers

PFP-M                                                                                         PFP-S

                                                                                                                                                         16

                                                M4 spring        10                                                                      5             12

                                                washer           6.2

                                                                              1.8

                                                                 1

                                   50                                         35.5  35.3                                                         44.3          34.8

                                                                         1.8

                                       11.5                      1.3

                                             M4 x 8 pan          4.8

                                             head screw                                                                                                16.5

                                                                                                                                                                                   19
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       SDV

Installation

■ Internal Circuit

Input and power supply circuits are electrically isolated as                                                                                                     protection                                                            against mutual                                                interference.

SDV-F@@/SDV-FH@T

                           Range selector switches                                                                                                                                                                                                                                                                                                                    SW9

           AC/DC selector                                                                                                                                                                                                                                                                                                                                             Buffer circuit                    VR                                      Timer timesetting circuit

           switch SW2

           (see note 4)         SW6 SW5 SW4                                     SW3

                           Polarity selector switch

                           (SW2)                             Amplifier circuit           Operating value                   Absolute value                                                                                                                                                            Power circuit                                                    Buffer circuit                                   discharge circuit                                   Comparator

                           (see note 3)                                                                   setting circuit                    rectifier circuit                                       Comparator                                                                    Inverter circuit                    SW7                           voltage circuit                                    Quick charge/

Input     8                                                                                                                                                      Smoothing                                                                                                                                                  Startup lock  reference                                                                                                                                    circuit

          7                                                                                                                                                               circuit                                     circuit

                                                                                                                                                                                                                                                                  SW1

                                 To                                                                                                                                                                                   voltage circuit                 Overvoltage/                                                                                                                    Inverter circuit                                                                     Reference  voltage circuit

                                 each     Power                                                                                                                  2                                                                                    Undervoltage

          5                      circuit                                                 Chopper                                                                                                     Reference                                        selector switch

                                          supply                                                                                                                            Power

                                          circuit                                        circuit                                                                            supply                                                                    SW1

                                                                                                                                                                 1                                                                                                                                                                        SW8

          4                X/c                                                       DC Power supply circuit

                                 To                                                                                                                              2                                   Releasing valuesetting circuit                                                                                 X       Note:                                     The SDV-FH@T contains

          3                      each     Power

                                 circuit  supply                                                                                                                            Power                                                                                                                                                                                     the circuit outlined with the

                                                                                                                                                                            supply                                                                                                                   Output relay

                                          circuit                                                                                                                1                                                                                                                                                                                                    dotted line.

                                                                                AC Power supply circuit

                          Note:      1.   There is no polarity setting for the SDV-FM or SDV-FH/-FH@T.

                                     2.   There is no power supply polarity setting when using a DC control                                                                                                                                                                                                                 power                    supply                           for               the                               SDV.

                                     3.   The polarity selection switch (SW2) is on the SDV-FL.

                                     4.   The AC/DC switch (SW2) is on the SDV-FM and SDV-FH/-FH@T.

SDV-D

                           Range selector switches                                                                                                                                                                                                                                                   Output relay for

                                                                                                                                                                                                                                                                                   Power circuit     overvoltage

                                                                                                                                                                                                                                                      Comparator  circuit(High)                      detection

                                                                                                                           Output relay for                                                                                                                                                          XH

          AC/DC selector                                                                                                                   overvoltagedetection

          switch SW1       SW5       SW4 SW3                                    SW2

       15                                 Amplifier circuit                              Absolute valuerectifier circuit   Smoothing                                               Addition circuit     Dear band                    setting circuit  Reference   voltage circuit

Input  10                                                                                                                                    circuit                                                                                                                                                 Output relay for

                                                                                                                                                                                                                                                                                   Power circuit     undervoltage

       12                                                                                                                                                                                                                                             Comparator  circuit(Low)                       detection

                                XL/a      To                                                                                                                                                                                                                                                         XL

       5                                  each                                                                                                                                                       2

       4                                  circuit                               Power                                      Chopper                                                                      Power

                                                                                supply                                     circuit                                                                      supply

       3                        XL/b                                            circuit                                                                                                              1

                                                                                         DC Power supply circuit                                                                                                                                                  voltage circuit

       6                        XH/a      To                                                                                                                                                                                                          Reference

       7                                  each                                                                                                                                                       2

                                          circuit                               Power                                                                                                                   Power

       8                                                                        supply                                                                                                                  supply

                                XH/b                                            circuit                                                                                                              1

       9                                                                                 AC Power supply circuit

                         Note:   1.       There                                 is no power supply polarity setting when                                                                                                                                                           using a DC control                  power              supply                           for        the                              SDV.

                                 2.       There                                 is no polarity setting for DC inputs.

                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            20
                                                                                                                                    SDV

Safety Precautions

Approximately 0.5 s is required for operation. When confirming the

operating value, gradually change the input voltage while checking

the value.

Power supply voltage fluctuations and the ambient operating temper-

ature must be maintained within the allowable ranges. Be particularly

careful not to apply an overvoltage beyond the specified range for the

voltage detection.

Do not use the SDV in locations subject to corrosive or explosive

gases.

The SDV cannot be used to detect momentary power interruptions

because of its response time. Use the S87A to detect momentary

power interruptions.

                     S87A Power Interruption Detector

An SDV cannot be used with a circuit containing thyristors, or VVVF

inverters, because these elements can change the output waveform

to the point that the SDV will malfunction.

Mounting

When mounting with the PL08 or PL15 Back Connection Socket,

insert the Socket into a 1- to 4-mm panel from the back and secure it

with  screws.  Do    not  mount  the  SDV       until  the  Socket   has  been

mounted     firmly.  Be   sure  that  the  key  groove      on  the  Socket  is

mounted on the bottom, and also secure the SDV to the panel with

screws.

When mounting with the 8PFA or 14PFA Back Connection Socket,

insert the SDV into the Socket and secure it with the hooks. Leave

approximately 30 mm or more between Sockets to allow enough

space for the hooks.

When mounting more than one SDV, allow at least 30 mm or more

between them.

                      ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                      To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                      In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                    21
                                                     Terms and Conditions Agreement

Read and understand this catalog.

Please read and understand this catalog before purchasing the products.                 Please consult your OMRON representative if you

have any questions or comments.

Warranties.

(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship

for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron

disclaims all other warranties, express or implied.

(b)  Limitations.      OMRON    MAKES           NO   WARRANTY          OR   REPRESENTATION,         EXPRESS             OR   IMPLIED,      ABOUT

NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER

ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE

PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.

Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the

Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at

Omron’s     election,  to  (i)  replace    (in  the  form  originally  shipped    with  Buyer  responsible  for  labor  charges  for  removal            or

replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount

equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,

repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products

were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate

modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall

not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or

electronic   components,        circuits,  system    assemblies  or    any  other  materials   or   substances   or  environments.    Any  advice,

recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above

warranty.

See http://www.omron.com/global/           or contact your Omron representative for published information.

Limitation on Liability; Etc.

OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,

LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,

WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.

Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.

Omron     Companies    shall    not  be    responsible     for  conformity  with  any   standards,  codes   or  regulations  which  apply  to            the

combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable

third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself

is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,

system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product

with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE

QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE

OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.

Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence

thereof.

Performance Data.

Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining

suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate

it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.

Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our

practice to change part numbers when published ratings or features are changed, or when significant construction changes are

made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers

may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at

any time to confirm actual specifications of purchased Product.

Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.

                                                                                                                                           2013.8

                                                           In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

http://www.ia.omron.com/                                                                       (c)Copyright OMRON Corporation 2013 All Right Reserved.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

SDV-DH1 DC12   SDV-DH2 DC24  SDV-DH3 DC48    SDV-DH4 DC100/110  SDV-DH6 AC100/110     SDV-DH7

AC200/220  SDV-DM1 DC12   SDV-DM2 DC24     SDV-DM3 DC48  SDV-DM4 DC100/110  SDV-DM6 AC100/110       SDV-

DM7 AC200/220  SDV-FH1 DC12  SDV-FH2 DC24    SDV-FH3 DC48     SDV-FH4 DC100/110   SDV-FH5T DC125V   SDV-

FH61   SDV-FH6 AC100/110  SDV-FH7 AC200/220  SDV-FL1 DC12     SDV-FL2 DC24  SDV-FL3 DC48   SDV-FL4

DC100/110  SDV-FL61     SDV-FL6 AC100/110  SDV-FL7 AC200/220  SDV-FM1   SDV-FM2 DC24  SDV-FM3 DC48

SDV-FM4 DC100/110    SDV-FM6 AC100/110     SDV-FM7 AC200/220  SDV-SH10  SDV-SH15  SDV-SH5  SDV-SH7.5

14PFA  PL15

小广播

14PFA器件购买:

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved