Heavy Duty Power Connectors PP PAK 2-4P HSG SNAP-IN RECEPT

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Anderson Power Products
产品种类:
Product Category:
Heavy Duty Power Connectors
RoHS:YES
系列:
Series:
PP15/45
产品:
Product:
Housings
位置数量:
Number of Positions:
-
端接类型:
Termination Style:
-
外壳材料:
Housing Material:
Polycarbonate (PC)
主体材料:
Contact Plating:
-
触点材料:
Contact Material:
-
封装:
Packaging:
Bulk
安装角:
Mounting Angle:
Straight
商标:
Brand:
Anderson Power Products
Flammability Rating:UL 94 V-0
安装风格:
Mounting Style:
Panel
触点类型:
Contact Gender:
-
用于:
For Use With:
Powerpole Connectors
Housing Gender:Female
产品类型:
Product Type:
Heavy Duty Power Connectors
工厂包装数量:
Factory Pack Quantity:
1
子类别:
Subcategory:
Power Connectors
商标名:
Tradename:
Powerpole
单位重量:
Unit Weight:
0.282192 oz

1470G1器件文档内容

Global Presence

Anderson Power Products (Anderson) Has A Global Distribution Network In The Following Countries Along With Many Others:

Argentina, Australia, Belgium, Brazil, Canada, Chile, China, Columbia, Denmark, France, Germany, Greece, Hong Kong, Ireland,

Israel, Italy, Japan, Mexico, New Zealand, Norway, Peru,    Poland, Portugal, Singapore, Slovenia, South Africa, South Korea, Spain,

Switzerland, Thailand, Turkey, United Kingdom and United States.

Our philosophy is to provide products and services within the trading markets of our customers. We currently

serve our worldwide customer base from customer support and manufacturing facilities in Sterling, MA, U.S.A.,

Warrington UK for European customers, as well as three Asia Pacific facilities: Shenzhen, China, Shatin Hong

Kong and Taichung City 407, Taiwan (R.O.C.).

Today, as a result of innovative design and development, we have evolved into a valued supplier for a wide

variety of markets including Back-up Power, Telecom / Datacom, Alternative Energy Generation & Distribution,

Medical Equipment, Defense, and the Material Handling Industries.

We have established a reputation for high quality products, on-time deliveries, and excellent customer service. As a

result of modern manufacturing techniques and rigorous quality control measures, this assures our customers receive

the quality products they deserve.

As a global company dedicated to best environmental practice, we have taken steps to meet the RoHS directive

for virtually all products. We look forward to the challenges posed by the new technologies of the future and will

continue our century long tradition of design excellence and superior customer support to meet customers’ needs.

© 2018 Anderson Power Products, Inc.  All rights reserved.  This catalog or it’s content may be downloaded only for your personal, non-commercial use.

Anderson will use reasonable efforts to include accurate and up-to-date content in the catalog. All product information contained in the catalog including ordering

information, illustrations, specifications, and dimensions, are believed to be reliable as of the date of publishing, but is subject to change without notice. Anderson makes

no warranty or representation as to its accuracy. Content in the catalog may contain technical inaccuracies, typographical errors and may be changed or updated without

notice. Anderson may also make improvements and/or changes to the products and/or to the programs described in the content at any time without notice. Current sales

drawings and specifications are available upon request.

Neither Anderson nor any party involved in creating, producing, or delivering this catalog shall be liable for any direct, incidental, consequential, indirect, or punitive

damages arising out of your use of this catalog or any errors or omissions in its content.

All product names, including, but not limited to A®, A in circle, Anderson Power Products®, APP®, Powerpole®, SB®, SBE®, SBO®, SBS®, SBX®, SPEC Pak®,

Saf-D-Grid®, Power Clip®, Power Drawer®, PowerMod® and the APP Logo are registered trademarks of Anderson Power Products, Inc.  Anderson™ is a trademark of

Anderson Power Products, Inc.

www.andersonpower.com
SECTION 1                                                                                           -  SB®50 ................................................         67

• Index & Product Selector ..............................   1                                       -  SB®120 ..............................................      72

• Technical Reference .....................................   4                                     -  SB®175 ...............................................         77

• Glossary ........................................................ 10                              -  SB®350 ...............................................   82

• Engineering Reference ................................. 12                                        -  SBE®80 / SBO®60 ...............................                87

                                                                                                    -  SBE®160 / SBX®175 ...........................     92

SECTION 2                                                                                           -  SBE®320 / SBX®350 ...........................     98

• Powerpole® Connectors ............................... 16                                                  - PPMX Auxiliary Holder for

    - PP15 to PP45 ....................................... 20                                 SBO®, SBE® & SBX® .....................    90,                 96,  102

                  - Powerpole® Pak .................................... 23                                        -  SB® SMART  .......................................             105

                  - Powerpole® PP75 ................................. 32

                  - Powerpole® PP120 ............................... 39                         SECTION 4

                  - Powerpole® PP180 ............................... 43                          • Tooling .........................................................  109

                                                                                  SECTION 5

SECTION 3                                                                          • Part Number Page Reference .....................                   115

• Multipole Connectors ....................... .................   48

                  - SBS® Mini  ........................................... . 53

                  - SBS® 50 & 75 ....................................... 57

                                           Powerpole® Connector                       Family  Multipole Connector Family

           Page Number                                                  16                          48

           Amps (UL) Per Pole                                           Up to 350                   Up to 500

           Volts (UL) Per Pole                                          Up to 600                   Up to 600

           Wire Gauge (AWG)                                             20 - 3/0                    16 - 350 mcm

           Wire Gauge (mm²)                0.75 - 85.0                                              1.3 - 150

           Number of Power Circuits        1 / Stackable                                      2  -  3 / Not Stackable

           Ground                                                       ●                           ●

           Auxiliary                                                                                ●

           PCB Mount                                                    ●                           ●

           Bus Bar                                                      ●                           ●

           Panel Mount                                                  ●                           ●

           Blind Mate                                                   ●

           Hot Plug                                                     ●                           ●

           Touch Safe                                                   ●                           ●

           Strain Relief                                                ●                           ●

           Polarized Housing                                            ●                           ●

           Mechanically Keyed                                                                       ●

           Latching                                                     ●

           Handle                                                                                   ●

           Air Supply System                                                                        ●

All Data Subject To Change Without Notice                                                               www.andersonpower.com                                     -1-
                                       Custom Connector Capabilities

           Index / Prod. Selector  We specialize in the design and manufacture of high current connection systems to meet specific customer needs. Our

                                   expertise in high amperage connections, multiple types of contact technology, and molded plastic insulators allow us

SECTION 1                          to provide durable, high power connections that fulfill the project requirements of OEM’s.

                                   We look forward to working with OEM’s on their manufacturing scale projects to provide connector solutions which

                                   our current product portfolio may not satisfy.  Marketing, Engineering, Quality, Safety Agency, and Manufacturing

                                   teams all contribute through the integrated product development process to create and deliver custom connectors

                                   that exceed our customers’ needs and meet our high standards.

                                   Contact your local customer service representative or regional sales manager to explore how our custom design and

                                   manufacturing capabilities can meet your high volume connection needs.

                                   | HOW TO USE THIS CATALOG |

                                   The information in this catalog is provided in layers to allow you to quickly find the information you are looking for.

                                   1) Selection Guides are featured at the front of the catalog and at the beginning of each product section to enable quick

                                       connector selection by electrical attributes and other features.

                                   2) A Technical Reference is provided to give important information common to all connectors in this catalog. Answers

                                       to common questions, definitions of terminology, and technical charts are all included.

                                   3) Overviews at the beginning of each product main section describe the similarities and call out common features of

                                                     products within that section.

                                   4) Introductions to the features and benefits of each product are supplied at the beginning of each sub-product

                                                     section (SB®50, SB®120, etc).

                                   5) Specifications and Temperature Charts are shown after the main connector components in each sub-product

                                       section to provide detailed technical information (SB®50, SB®120, etc).

                                   6) Tooling Charts are provided at the end of each connector family (SB®, SBS® etc) to quickly identify the correct tooling.

-2-                                    www.andersonpower.com                                                                    All Data Subject To Change Without Notice
| PRODUCT SELECTION WORKSHEET |

Prior to selecting an interconnect solution, we recommend you gather the following                      information. This  will aid  Index / Prod. Selector  SECTION 1

you in quickly identifying the best product for your particular need.

Amps

      Continuous    ________________                                            max amps at  ___________     volts

      Peak      _____________________                                           max amps  ___________        seconds

Temperature

      Operating _____________                                                          Storage  ____________

Circuit Definition

                                  Number of Circuits:                                         Wire Gauge:

      Power         ____________________                ________________________

      Ground        ____________________                ________________________

      Auxiliary ____________________                ________________________

      Other         ____________________                ________________________

Application

      □  PCB to PCB                               □  Wire to PCB           □  Wire to Bus Bar           □ Wire to          Wire

      □  Wire to Panel                            □  Other _______________________________

Mounting Method (if applicable)

      □  PCB                                      □  Panel                 □  Blind Mate

Contacts

      □  Mating Cycles                     _____  □  Individual            □  Reeled

      □  Tin                                      □  Silver                □  Gold

      □  Straight                                 □  Right Angle

Other Features

      □  Hot Plug                                                          □  Touch Safe per _______

      □  Flame Resistance per ___________                                  □  IP rating of __________

      □  Sequencing                                                        □  Strain Relief

      □  Polarized Housing                                                 □  Mechanical Housing Key

      □  Latching                                                          □  Handle

      □  Other _____________________________________________________________________________________

      ____________________________________________________________________________________________

      ____________________________________________________________________________________________

NOTES:

All Data Subject To Change Without Notice                                                               www.andersonpower.com        -3-
SECTION 1  Technical Reference  | GENERAL APPLICATION NOTES |

                                There are common considerations when using our connectors. Additional considerations may apply based on the

                                particular connector being used, the application, and conditions in which it’s being used. This information is intended

                                to provide a basic understanding and is provided for reference only. Connectors should be assembled and used ac-

                                cording to the equipment and the manufacturer’s instructions, as well as in compliance with local and international

                                electrical codes.

                                The maximum amperage ratings provided in the specifications are based on use of our recommended assembly

                                tooling and the maximum wire size for the connector being used. Amperage ratings are based on not exceeding the

                                maximum operating temperature of the connector housing, factoring in an ambient temperature of 25°C or 77°F.

                                A wire with an appropriate insulation temperature rating should be selected to meet or exceed the total connector

                                temperature (heat rise + ambient).

                                As an example: if the maximum operating temperature for a connector operation is 105°C and the ambient temperature

                                is 25°C, the maximum heat rise attributable to the connector is 105°C - 25°C = 80°C. The expected heat rise based

                                on the connector and wire size used can be estimated using the heat rise charts, but should be confirmed by testing

                                in the specific application with the specific wire to be used.

                                Connector devices are rated or derated by the wiring configuration and the environment. Factors to be considered include:

                                enclosure characteristics, connector housing and wire insulation characteristics, number of wires in an enclosed area

                                such as a raceway or conduit, as well as the ambient temperature.

                                Underwriter Laboratories Inc. amperage ratings are based on not exceeding the maximum operating temperature of

                                the connector housing. This means connectors can be extremely hot when used at the UL amperage ratings. For this

                                reason UL amperage ratings should only be applied to connectors when they are used inside an enclosure not accessible

                                to untrained persons. Canadian Standards Association ratings are based on not exceeding a 30°C temperature rise

                                above ambient temperatures. For this reason CSA amp ratings are a good point of reference for connectors that are

                                user operated. APP does not recommend exceeding a 30°C temperature rise above ambient temperatures for connections

                                accessible during operation to untrained persons.

                                | HOW TO READ TEMPERATURE CHARTS | Temperature rise charts                         are based on a 25°C ambient temperature.

                                Temperature Rise at Constant Current Charts                                                                                                 SB®50

                                                                                                                                                                Temperature Rise at Constant Current

                                Temperature Rise at Constant Current charts show the associated heat rise                                                60

                                as a result of applied current to the connector. An example of the SB®50 con-                                            50

                                nector Temperature Rise chart is included to follow along with this explana-       Temperature Rise  Above Ambient (°C)

                                tion.                                                                                                                    40

                                The    chart  is  based  on  an      ambient  temperature  of   25°C  (77°F  room                                        30

                                temperature). Accordingly if the temperature °C on the Y axis of the chart is at                                         20

                                30°C, the expected total connector temperature would be 55°C.                                                            10

                                Separate curves are shown for #6, #8, #10, and #12 AWG wire. Interpreting                                                0   0  10  20  30  40  50  60   70  80       90

                                the curves, if 50 amps are applied continuously to the connector, the heat rise                                                         Amperes Applied

                                will be 23°C for #6, 35°C for #8, 55°C for #10, and #12 wire is not suitable for                                                    6 AWG                8 AWG

                                this amperage.                                                                                                                      10 AWG              12 AWG

                                Where T = Temperature, heat rise is expressed as a ΔT°C.

                                T ambient - T (ambient + heat from applied current) = ΔT°C.

-4-                                           www.andersonpower.com                                                                                                 All Data Subject To Change Without Notice
Derating vs. Ambient Temperature Charts                                                                                                                        Technical Reference  SECTION 1

Derating vs. Ambient Temperature charts show the maximum amperage                                                               SB®50

capability of a connector at a given ambient temperature. An example of                                          Derating vs. Ambient Temperature

the SB®50  connector chart is included to follow along with this explanation.                            125

All data points are based on the maximum operating temperature of the          Ambient Temperature (°C)  100

connector, most often 105°C or 221°F. Accordingly if the temperature °C

on the Y axis of the chart is at 105°C, there is no amperage capability                                  75

because the connector housing is already at the maximum operating

temperature.                                                                                             50

Separate curves are shown for #6, #8, #10, and #12 AWG wire.                                             25

Interpreting the curves, at a 75°C ambient temperature the maximum                                            0  10  20  30  40  50    60  70  80  90  100

amperage capability that can be applied continuously to the connector is:                                                    Amperes Applied

58A for #6, 46A for #8, 37A for #10, and 31A for #12 wire.                                                               6 AWG                 8 AWG

                                                                                                                     10 AWG                12 AWG

Notes on Temperature Rise Charts

Note that these charts are constructed using calculations based on actual test data. For this reason the chart

information may vary slightly from the safety agency ratings. Safety agency ratings and compliance with electrical

codes take precedent over these charts. The charts are designed to provide a guideline as to the connectors’ capability.

Actual results can vary based on the specific wire used, crimp tooling and assembly, as well as the environment the

connector is used in.

CSA ratings are based on not exceeding a 30°C temperature rise above ambient or a total temperature of 55°C. This

is considered the maximum temperature to safely handle a connector at. UL ratings can be based on the operating

temperature limit of the connector. Often for our connectors this is 105°C or an 80°C temperature rise above an am-

bient temperature of 25°C. To provide a margin of safety, the heat rise charts are limited to a 60°C temperature rise.

| COMPATIBLE WIRES |

Al                 Cu

Our connectors are designed to be crimped and/or soldered to multi-stranded copper conductor wires only.

Alternate conductor materials including aluminum should not be used. Aluminum conductors crimped into our

contacts can result in a galvanic reaction occurring between the aluminum wire and the more cathodic metals

used in our contacts including copper, tin, silver, and gold. Additionally softer metals like aluminum flow or loosen

from crimps much easier than copper.

Multi-stranded wire is recommended for all our connectors and is required when crimp terminating wires or when a

connector with flat wiping contact technology is used (such as Powerpole® and SB®). Solid wires do not adequately

compress and retain in crimp barrels after being crimped. For this reason if solid wire is used, it should be with solder

termination only.

Solid wires also do not flex and bend as easily as multi-stranded equivalents and can act as a lever arm and impede

or alter the natural state of a flat wiping contact in the housing. This impediment or alteration to the flat wiping contact’s

natural state can cause intermittency and shorts as well as higher resistance and temperature at a given amperage

than is shown in the specifications. Mating and unmating forces may also be impacted.

All Data Subject To Change Without Notice                                                                            www.andersonpower.com                  -  5  -
                                | DIFFERENT CONTACT TECHNOLOGIES |

           Technical Reference  Flat Wiping:

                                • Same contacts on the “male” and “female” side reduce inventory costs and increase ease of assembly.

                                • Low resistance connection has a large conducting surface and a high normal force in comparison to typical pin

SECTION 1                                        and socket contacts.

                                • Sacrificial tip confines damage to non-conducting area when mating or breaking under load.

                                • Raised surface on the mating side of the contacts secures the connector in the mated condition, limiting the

                                                 need for latching on outer housings.

                                • Over wiping design cleans the mating surface when mating and unmating.

                                                                                         - VS -

                                               Solid line

                                               of electrical                                                  Select points of

                                               contact.                                                       electrical contact.

                                Flat Wiping Technology                                           Pin & Socket Technology

                                Pin & Socket:

                                • Different contacts on male and female sides. Female socket contacts are typically more expensive than the

                                                 simple geometries of the pin contacts.

                                • Often higher resistance than flat wiping connectors of the same wire size and plating due to the reduced mating

                                                 surface area and lower normal force. Gold plating often used to compensate and minimize resistance.

                                • Best for compact connection needs such as signal and low power due to static position in housings and

                                                 symmetrical shape.

                                • Socket contacts can catch and hold debris inside the socket body causing mating problems.

                                | USE OF ANDERSON™ CONNECTORS IN APPLICATIONS EXCEEDING 600V |

                                The approved voltage ratings for our connectors are usually limited by the category under which a safety agency such

                                as UL approves our connector for use. UL typically defers to National Electric Code (NEC) on the voltage limitations for

                                any given device our connector could be used in. For most common applications NEC restricts voltage to a maximum of

                                600V AC or DC which is what our connector voltage ratings are based on.

                                To achieve UL 1977 approval for a 600V rating, we test our connectors for dielectric withstanding voltage. The connector

                                is tested at 2 times the rated voltage of 600V plus 1000V or 2200VAC for 1 minute.  For applications exceeding 600V,

                                UL / NEC / IEC may require application specific review for creepage and clearance resistance.

                                | FREQUENTLY ASKED QUESTIONS |

                                Q: Can I cross mate low and high mating force contacts?

                                A: Yes, however this would not be a connection solution we have tested for safety agency approval. Additionally the

                                contacts may wear at an accelerated rate causing the mating cycle rating to be reduced. The mating and unmating

                                force expected would be somewhere in between the high and low mating force specification.

                                Q: Can I crimp multiple wires into 1 crimp barrel?

                                A: Yes, however this would not be a connection solution we have tested for safety agency approval. Particular care

                                should be used that the bundle of wires do not interfere with the movement of the contact in the housing during mating

                                and unmating (see maximum wire O.D. specification). The total circular mils of all conductor stands should be within

                                + or – 5% of the wire size the contact is intended for. Twist the conductor strands together and crimp using our tooling

                                with range taking capabilities such as the 1368 series. To crimp with other Anderson™ recommended tools, contact

                                customer service for the recommended setting or die and locator combination.

-6-                             www.andersonpower.com                                                                              All Data Subject To Change Without Notice
Q: Will the crimp tool I have for standard color-coded lugs, Mil Spec contacts, or another connector                       Technical Reference  SECTION 1

manufacturer, work for crimping Anderson™ contacts?

A: No. Our contacts generally do not conform to standard crimp barrel dimensions used for lugs, Mil Spec contacts, or

other connector manufacturers. The tooling recommended by us must be used to ensure the performance designed

by us is achieved. Alternate tooling will void our warranties and can affect safety agency approvals. In some instances

Mil Spec tools are approved for crimping contacts with the dies and locators recommended by us. See tooling charts

for specific instances, or contact customer service for more information.

Q: Can metric sized wires be used with Anderson™ contacts?

A: Yes. The majority of our crimp tooling recommendations are based on testing and verification we have performed

with AWG sized cables. Metric cables of the same or slightly smaller circular mils equivalent to the AWG wire recommended

can typically be successfully terminated in our contacts. There is a wire conversion chart at the end of this catalog

section that can be used as a reference when converting AWG to mm² sizes. The 1368 series crimp tooling has a

range taking capability that produces a reliable crimp with metric equivalents of AWG cables. Please contact customer

service for metric tooling recommendations for other Anderson™ crimp tools.

Q: Are Anderson™ connectors suitable for use in applications where the voltage exceeds 600V AC/DC?

A: Possibly. See “Use of Anderson™ Connectors in Applications Exceeding 600V”, contact customer service with

further questions.

Q: How do Powerpole® and Multipole connectors stay securely mated without latches?

A: The proven flat wiping technology used in these connectors features a detent or bump in the contact surface along

with powerful stainless steel springs that hold the connectors in the mated position. High mating force contacts have

a detent that is raised higher than low mating force contacts. The higher the detent, the more force is required to mate

and unmate the contacts. In many applications the detent and spring force is enough to securely hold the connectors

in the mated position without the need for latches. Latching shells, clips, or other external devices can be used to

secure flat wiping connectors in applications where shock, vibration, or cable strain may overcome the inherent force

holding the connectors together.

Q: How does Anderson’s genderless connector design work to make a mated pair.

A: Genderless Powerpole® and Multipole housings do not have a male(pin) and female(socket) side. For wire-to-wire

applications the exact same housings and contacts are used on both sides of the mated pair. If your application calls

for wire-to-PCB or wire-to-busbar connections then different contacts and possibly housings will be required on each

half (similar to male and female connectors).

To make a mated pair of Powerpole® or Multipole connectors simply assemble the connectors closely following the

assembly instructions. After each connector half is fully assembled take one half and flip it over. The two halves will

mate together. Multi-row Powerpole® assemblies will need to be stacked in mirror images of each other to properly

mate the correct circuits. This information is detailed at the beginning of the Powerpole® section.

All Data Subject To Change Without Notice                                      www.andersonpower.com                       -7-
                                | TOUCH SAFETY & INGRESS PROTECTION (IP) |

           Technical Reference  UL 1977 Section 10.2:

                                Typically required for applications where the connector is external to the end device and operating over 30V or 200A,

SECTION 1                       where wet conditions may be present (600V category).

                                Testing is performed using a probe that mimics a child’s finger. All features of the connector are tested for live parts

                                in the unmated state (no pressure applied). A smaller 3 mm probe is then applied in the mated state to test for live

                                parts. Note that some applications may require the connector to not expose live parts to the 3 mm probe in the mating

                                interface.

                                IEC 60950:

                                From the standard for Information Technology Equipment Safety, the requirements are harmonized with UL1950. Typically

                                required for commercial and industrial applications where operators may need some degree of protection while accessing

                                or servicing equipment.

                                Testing is performed using a probe that mimics an adult finger. All features of the connector are tested for live parts in

                                the unmated state with 30 N of force applied to the probe.

                                IEC 60529:

                                Standard for Degrees of Protection Provided by Enclosures is harmonized with EN 60529.

                                Protection degree number is assigned to both solids and liquids in that order. For example: a connector with an IP20 rating

                                is protected against fingers, but has no protection against ingress of liquids.  We take a conservative approach in rating our

                                connectors against liquid ingress and consider any meaningful water ingress to have a harmful effect.

                                Protection                         Solids (First Digit)                              Liquids (Second Digit)

                                            Degree       Description     Protected Against           Description                Protected Against

                                            0                         Not Protected                                             Not Protected

                                                                         Large body part such as     Vertically dripping water  Duration: 10 minute

                                            1            > 50 mm         back of hand                (no harmful effect)        Water: 1 mm / minute rainfall

                                                                                                                                Pressure: N/A

                                                                         Adult fingers or similarly  Tilted 15 degrees up       Duration: 10 minute

                                            2            > 12.5 mm       sized objects               dripping water             Water: 3 mm / minute rainfall

                                                                                                     (no harmful effect)        Pressure: N/A

                                                                         Typical screw drivers or    Water spray up to 60       Duration: 5 minute

                                            3            > 2.5 mm        large wires                 degree angle               Water: 0.7 liter / minute

                                                                                                     (no harmful effect)        Pressure: 80-100 kN/m²

                                                                         Small pointy tools and      Water splash from          Duration: 5 minute

                                            4            > 1 mm          small wires                 any direction              Water: 10 liter / minute

                                                                                                     (no harmful effect)        Pressure: 80-100 kN/m²

                                                                         Complete physical           Water jet from any         Duration: 3+ minute

                                            5            Dust protected  protection, no functional   direction                  Water: 12.5 liter / minute

                                                                         interference from dust      (no harmful effect)        Pressure: 30 kN/m² @ 3 m distance

                                                                         Complete physical           Strong water jet from      Duration: 3+ minute

                                            6            Dust sealed     protection and sealed       any direction              Water: 100 liter / minute

                                                                         from dust ingress           (no harmful effect)        Pressure: 100 kN/m² @ 3 m distance

                                                                                                     No ingress of water        Duration: 30 minute

                                            7                                                        in harmful quantity        Water: Immersion

                                                                                                     when immersed up           Pressure: 1 m depth

                                                                         N/A                         to 1 m depth

                                                                                                     No ingress of water        Duration: Mfg. specified

                                            8                                                        in harmful quantity        Water: Immersion

                                                                                                     when subject to tests      Pressure: 1+ m depth. Mfg. specified

                                                                                                     in excess of condition 7

-8-                                         www.andersonpower.com                                                                              All Data Subject To Change Without Notice
| PREVENTIVE MAINTENANCE |

Damaged connectors, contacts and cables may present hazards, resulting in inefficient battery and charger operation.          Technical Reference  SECTION 1

To avoid these problems, conduct the following maintenance checks at least once annually.     If you see any of the

following problems, take corrective action immediately.

1.  Dirty Connectors

When engaged and disengaged, the contact surfaces of Anderson SB® Connectors “over wipe,” thus providing

a self cleaning action.   To ensure the continued benefit of this feature, clean the contact surfaces and lubricate

the connector.  Use a “white” lithium grease, which may be obtained from hardware stores and automotive parts

suppliers.

2.  Melting Connectors

Connector housings overheat and melt for many reasons. To prevent this:

    A. Examine the crimp between cable and contact.      Ensure the crimp tooling recommended by us has been

                  used.      Improper crimping, corrosion, and broken wires result in unnecessary resistance causing the contact

                  to heat up.

    B. Check contact surfaces for signs of  “pitting” caused by dirt or disengaging connectors under load.   One

                  badly pitted contact, particularly in a connector attached to a battery charger, can lead to pitting on surfaces

    of other contacts.  If not corrected, this can result in an epidemic of bad connectors throughout a fleet of electric

                  vehicles and in chargers and batteries.

    C. Check to see if batteries are being disconnected while the charger is still on. This causes the contacts to arc                

                  at the tips, resulting with progressive pitting and silver removal from tip to crown.     If this practice is occurring,

    discontinue it now to avoid major repairs in the future.

3.  Other Conditions

If any of the following conditions exist, the connector housing, contact and/or cable should be replaced immediately.

    A. Housing: Cracks, missing pieces, evidence of excessive heat, discoloration. You may consider replacing the existing

                  housing with a Chemical Resistant equivalent for improved durability against UV rays and common solvents and

                hydrocarbons.

    B. Contacts: Pitting, burns, corrosion, excessive wear and cracked crimp barrels,

           as shown in image “B”.

    C. Cable:  Exposed copper near housing, cracked cable, peeling or frayed insulation.

    D. Handles:  Loose attachment and signs of damage as missing or loose hardware

    and cracked or broken plastic (Handles should be used for connectors that are

    hard to reach or move.)

    E. Cable Clamps:    Loose attachments, signs of abraded cable jacket, missing

                  or loose hardware.                     (Cable clamps should be used to relieve strain on

                  unmounted cable.)

                                                                                              Uncrimped Good         Damaged

                                                                                              Contact                Contact

                                                                                                                           B

    A

               Damaged Housing                           Good Condition

All Data Subject To Change Without Notice                                                     www.andersonpower.com           -9-
SECTION 1            Amp / Ampere: Measurement            increment     of  electric  current.    Flammability: The measure of a material’s ability to support combustion.

                     Abbreviated as “I”.                                                          Often tested per UL94.

           Glossary  Applicator: A semi-automatic termination machine consisting of an            Flat Wiping: The sliding action which occurs when contacts are mated.

                     upper and lower half that is used to crimp contacts onto wire. Used in       Wiping has the effect of removing small amounts of contamination from

                     conjunction with an electrical/ mechanical press.                            the contact surfaces, thus establishing better conductivity.

                     AWG: American Wire Gauge. A standard system for designating wire             Genderless: See “Hermaphroditic”

                     diameters.

                                                                                                  Heat Rise: Temperature rise associated with the electrical load applied

                     Blindmate: To join two connector halves in a normal engaging mode            to a mated connection.

                     without visual orientation.

                                                                                                  Hermaphroditic (Genderless) Connector: A connector in which both

                     Busbar: Three dimensional constructions enabling electrical distribution     mating members are exactly alike at their mating face. There are no

                     of current in power electronic modules. Typically constructed of cop-        male or female members, but designs provide correct polarity.

                     per, busbars are most frequently used in power dense applications

                     where the busbar offers a cost or space savings over wire.                   Hot Plug / Hot Swap: Live connector insertion / extractions.

                     Color Coding: A system of identification for terminals and related devices.  IEC: International Electrotechnical Commission, a standard writing

                                                                                                  organization.

                     Contact Resistance: The electrical resistance of metallic surfaces

                     at their interface in the contact area under specified conditions when       Insulation Resistance: Ratio of applied voltage to the total current

                     carrying a specified test current.                                           between the two electrodes in contact with a specific insulation.

                     Contact Retention: Minimum axial load in either direction which a            IP: Ingress Protection, a standard per IEC 60529 for measurement of

                     contact must withstand while remaining firmly fixed in its normal position   ingress for solids and liquids into an enclosure.

                     within a housing.

                                                                                                  Locator / Positioner: Device for positioning contacts into crimping dies.

                     Crimp Retention: The axial load which a contact can withstand without

                     separation from the wire.                                                    Make-First     /  Break-Last  (Premate):  Sequencing  of      contact(s)   so

                                                                                                  that they engage prior to the main power contacts. Typically used

                     Crimp Termination: A connection in which a metal sleeve is secured           for ground / positive earth / neutral positons as a protective measure

                     to a conductor by mechanically deforming the sleeve with presses or          against excess currents, short-circuits, and ground faults.

                     automated crimping machines, eliminating the need for solder. Not

                     suitable for solid (non-stranded wires).                                     Make-Last / Break-First (Postmate): Sequencing of contact(s) so that

                                                                                                  they engage after the main power contacts. Typically used for signal or

                     CSA: Canadian Standards Association, a safety standard writing and           auxiliary power positions to ensure communications are not started or

                     testing organization.                                                        power circuits switched on until the power contacts are fully engaged.

                     Cycle Controlled: To determine if repetitive on/off conditions result        Mating Force: Force required to join two connector halves in a normal

                     in degrading the contact system which may lead to failures such as           engaging mode.

                     “thermal run away”.

                                                                                                  Modular: Refers to similar parts or modules used as building blocks. A

                     Detent: A bump or raised section projecting from the surface of a contact    modular connector is one in which similar or identical sections can be

                     for keeping the contact in position relative to another and released by      assembled together to provide the appropriate connector type or size

                     greater force.                                                               for the application.

                     Dielectric Strength (Withstanding Voltage): The highest potential            Ohms: Measurement increment of resistance.

                     difference (voltage) that an insulation material of given thickness can

                     withstand for a specified time without occurrence of electrical breakdown    Operating      Temperature    Range:  Connector    temperature     rating

                     through its bulk.                                                            established by materials used, plastic, finish, and the base metal.

                                                                                                  Applying an electrical load will result in a temperature rise that is

                     Finger Proof: A connector intended for usage external to the end             additive to the operating ambient.

                     equipment shall have live parts protected against exposure to contact

                     by persons when assembled, installed, and mated as intended, as              PCB: Acronym for Printed Circuit Board.

                     determined by UL Articulated probe.

- 10 -                               www.andersonpower.com                                                                                  All Data Subject To Change Without Notice
                                                                                                                                                        Glossary  SECTION 1

Polarization: A technique of eliminating symmetry so that parts may           Spring Loaded: A means of providing contact normal force with the

only be mated one way.                                                        use of a mechanical spring.

Pulse (Surge) Current: Highest instantaneous current that will run            Storage Battery: A voltaic battery consisting of two or more storage

through a system.                                                             cells. Energy is accumulated by chemical activity in the charging

                                                                              process and released on demand in the form of electric current.

REACH: The European Community Regulation on chemicals and their               Strain Relief: A means of termination or installation that reduces the

safe use. It deals with the Registration, Evaluation, Authorization and       transfer of mechanical stress from the conductor.

Restriction of Chemical substances.

Reducing Bushing: Separate tubular sleeve used to downsize the                Termination: Means of joining contacts to a conductor.

diameter of a crimp barrel to accept a smaller size wire.                     Touch Safe: See “Finger Proof”

Reeled Contacts: Contacts attached to a feeder strip for use in a high        Turret / Positioner: See “Locator”

volume crimping tool.

Resistance: The opposition to the passage  of  an          electric  current  TUV: The TÜV Rheinland Group is provider of technical services that

through that element. Abbreviated as “R”.                                     certifies products to standards written by other organizations.

RoHS: Restriction of Hazardous Substances Directive. The European             UL: Underwriters Laboratory, a safety standard writing and testing

directive on the restriction of the use of certain hazardous substances       organization.

in electrical and electronic equipment.                                       Volts: Measurement increment of electric potential.  Abbreviated as “E”.

Sacrificial Tip: An area of a contact system that absorbs electric arching    VDE: A German standard writing and testing organization responsible

to limit damage to the actual mating surface of the contacts.                 standards and safety specifications covering the areas of electrical

Self-Wiping: The sliding action which occurs when contacts are mated.         engineering, electronics and information technology.

Wiping has the effect of removing small amounts of contamination              Watt: Measurement increment of electric power.  Abbreviated as “W”.

from the contact surfaces, establishing better conductivity.

All Data Subject To Change Without Notice                                                                     www.andersonpower.com                     - 11 -
SECTION 1  Engineering Reference  | CONVERSION CHART FOR                        AMERICAN WIRE GAUGE          TO METRIC SYSTEM |

                                                                                Approximate                                                       Approximate

                                  AWG        Metric          Circ.  Equivalent  Wire Diameter  AWG   Metric  Circ.                    Equivalent  Wire Diameter

                                  Size       mm²             Mils   Circ.Mils   in.    mm      Size  mm²     Mils                     Circ.Mils   in.      mm

                                  -          0.5             -      937         0.032  0.81    1/0   -       106mcm*                  -           0.373    9.46

                                  20         -               1020   -           0.036  0.91    2/0   -       133mcm*                  -           0.419    10.60

                                  -          0.75            -      1480        0.039  0.99    -     70      -                        138.1mcm    0.430    10.90

                                  18         -               1620   -           0.046  1.16    3/0   -       168mcm*                  -           0.471    12.00

                                  -          1               -      1974        0.051  1.30    -     95      -                        187.5mcm    0.504    12.80

                                  16         -               2580   -           0.051  1.29    4/0   -       212mcm*                  -           0.528    13.40

                                  -          1.5             -      2960        0.063  1.60    -     120     -                        237.8mcm    0.567    14.40

                                  14         -               4110   -           0.073  1.84    -     -       250mcm                   -           0.575    14.60

                                  -          2.5             -      4934        0.081  2.06    -     150     300mcm                   -           0.630    16.00

                                  12         -               6530   -           0.092  2.32    -     -       350mcm                   -           0.681    17.30

                                  -          4               -      7894        0.102  2.59    -     185     -                        365.1mcm    0.700    17.80

                                  10         -               10380  -           0.116  2.93    -     -       400mcm                   -           0.728    18.50

                                  -          6               -      11840       0.126  3.21    -     240     -                        473.6mcm    0.801    20.30

                                  8          -               16510  -           0.146  3.70    -     -       500mcm                   -           0.814    20.70

                                  -          10              -      19740       0.162  4.12    -     300     -                        592.1mcm    0.891    22.60

                                  6          -               26240  -           0.184  4.66    -     -       600mcm                   -           0.893    22.70

                                  -          16              -      31580       0.204  5.18    -     -       700mcm                   -           0.964    24.50

                                  4          -               41740  -           0.232  5.88    -     -       750mcm                   -           0.999    25.40

                                  -          25              -      49340       0.260  6.60          400     -                        789.4mcm    1.026    26.10

                                  2          -               66360  -           0.292  7.42    -     -       800mcm                   -           1.032    26.20

                                  -          35              -      69070       0.305  7.75    -     500                              986.8mcm    1.152    29.30

                                  1          -               83690  -           0.332  9.43    -     -       1000mcm                  -           1.153    29.30

                                  -          50              -      98680       0.365  9.27    -     625     -                        1233.7mcm   1.287    32.70

                                  * Rounded  for simplicity

                                  NOTE: The above wire diameters and circular mils are based on an average of the most commonly available wires. The wire

                                  manufacturer’s specification should be referenced for information specific to the wire being used.

- 12 -                                       www.andersonpower.com                                                                    All Data Subject To Change Without Notice
     | VOLTS • AMPS • OHMS • WATTS CONVERSION |                                                              Engineering Reference  SECTION 1

                  WR                                     E           E               EI

                                                         R           I

                      W                                    W         W               I² R

                      I                                    R         I²

                      IR                                 W           E²              E²

                                                         E           W               R

     Volts =  Watts x Ohms                  Amperes =         Volts  Ohms =  Volts   W atts =  Volts x Amps

                                                              Ohms           Amps

     Volts =  W atts                        Amperes =         Watts  Ohms =  W atts  W atts =  Amps² x Ohms

              Amps                                            Ohms           Amps²

     Volts = Amps x Ohms                    Amperes =         Watts  Ohms =  Volts²  W atts =  Volts²

                                                              Volts          W atts            Ohms

     Wattage Varies Directly as a Ratio of Voltages Squared.

     W² = W¹  E²  x²

              E¹

     3 Phase Amperes =                      Total Watts

                                            Volts x 1.732

All  Data Subject To Change Without Notice                                           www.andersonpower.com   - 13 -
                                  |  STANDARD TO METRIC CONVERSIONS                             |

           Engineering Reference                Approximate Conversions                                  Approximate Conversions

SECTION 1                                    From: Standard / US Customary                               From: SI / Metric Units

                                                To: SI / Metric Units                                    To: Standard / US Customary

                                                When                                                     When

                                                You          Multiply                                    You          Multiply

                                     Symbol     Know         By            To Find      Symbol  Symbol   Know         By           To Find      Symbol

                                                             LENGTH                                                   LENGTH

                                     in         inches       25.4          millimeters  mm         mm    millimeters  0.039        inches       in

                                     ft         feet         0.305         meters       m          m     meters       3.28         feet         ft

                                                             AREA                                                     AREA

                                     in 2       square                     square       mm2        mm 2  millimeters  0.0016       square       in2

                                                inches       645.2         millimeters                                             inches

                                     ft 2                                  square       m2         m2    square       10.764       square feet  ft2

                                                square feet  0.093         meters                        meters

                                                             VOLUME                                                   VOLUME

                                                fluid                                              mL    milliliters  0.034        fluid        fl oz

                                     fl oz      ounces       29.57         milliliters  mL                                         ounces

                                     gal        gallons      3.785         liters       L          L     liters       0.264        gallons      gal

                                     ft 3                                  cubic        m3         m3    cubic        35.314       cubic feet   ft3

                                                cubic feet   0.028         meters                        meters

                                                             MASS                                                     MASS

                                     oz         ounces       28.35         grams        g          g     grams        0.035        ounces       oz

                                     lb         pounds       0.454         kilograms    kg         kg    kilograms    2.202        pounds       lb

                                                         TEMPERATURE                                                  TEMPERATURE

                                     oF         Fahrenheit   (F-32) x 5 /  Celsius      oC         oC    Celsius      1.8C + 32    Fahrenheit   oF

                                                                    9
                                                             or

                                                             (F-32) / 1.8

                                                FORCE and PRESSURE or      STRESS                        FORCE and PRESSURE or STRESS

                                     lbf        poundforce   4.45          newtons      N          N     newtons      0.225        poundforce   lbf

                                     lbf/in  2  poundforce   6.89          kilopascals  kPa        kPa   kilopascals  0.145        poundforce   lbf/in2

                                                per square                                                                         per square

                                                inch                                                                               inch

- 14 -                                       www.andersonpower.com                                                               All Data Subject To Change Without Notice
                                           | NOTES |

                                                                             Engineering Reference  SECTION 1

All Data Subject To Change Without Notice             www.andersonpower.com  - 15 -
                                                                                        ®

                              Powerpole® Connectors

                              - PP15 to PP180

                                                                                                  This versatile connector series invented by Anderson Power

                                                                                                  Products (APP®) meets a wide range of power connection

                                                                                                  needs. There are four basic housing sizes in the Powerpole®

                                                                                                  product family that allow specific amperage or wire size needs

           Powerpole® Family                                                                      to be filled in the most compact footprint. Powerpole® can

                                                                                                  handle up to 350 amperes per pole and accommodate wire

                                                                                                  ranges of  #20 AWG (0.75 mm²) to 3/0 (70 mm²). A wide range

SECTION 2                                                                                         of colored housing options can be stacked together to create

                                                                                                  a proven reliable custom connector. These housings can be

                                                                                                  used with different contacts to create wire-to-wire, wire-to-

                                                                                                  board,      or  wire-to-busbar            connections.       The  Powerpole®

                                                                                                  connector combines high quality materials and a cost effective

                                                                                                  innovative design to allow powerful versatility.

                                                                                                                  Stackable Modular Housings

                                                                                                                  Available       in  four  sizes   to  right

                                                                                                                  size your connection need

                                                                                                                                                        Color Coded Housings

                                                                                                                                                        Help ensure that connectors

                                                                                                                                                        are assembled and mated

                                                                                                                                                        correctly

                                                Genderless Housings

                                                Provide  simplified  assembly

                                                and minimize the number of

                                                components

                                                                                           Low Resistance Connection

                                                                                           Silver    or  tin  plated    contacts

                                                                                           inside    housings     that  strongly

                                                                                           force the contacts together

                              Self Securing Design

                              Stainless steel springs create

                              a  robust  force  between  the

                              contacts that holds the con-

                              nector in the mated condition,         Hot Plugging AC or DC

                              but allows it to be quickly dis-       Contacts feature a sacrificial

                              connected                              tip that allow high current

                                                                     circuit interrupt

                                                                                                                        Connection Versatility

                                                                                                                        Contacts for wire, PCB,

                                                                                                                        or busbar all fit into the

                                                                                                                        same housings

- 16 -                           www.andersonpower.com                                                                                                  All Data Subject To Change Without Notice
|  POWERPOLE® FAMILY SELECTION GUIDE                                                      |

   Powerpole® Size      PP15 to 45                  Page   #  PP75          Page       #  PP120           Page      #  PP180                                                  Page  #

   Connector Types            Standard                 20     Standard             32     Standard              39     Standard                                               43

                        Finger Proof                   20     Locking              32                                  Busbar                                                 44

                              PCB                      21     Busbar               33

                              Ground                   20     PCB                  33

                              Power Pak                23

   Amps (UL) Per Pole                      0 to 55                  120                          240                           350

   Volts (UL) Per Pole                     600                      600                          600                           600

   Wire Gauge (AWG)                        20 - 10                  16 - 6                       6 - 1/0               10 - 3/0

   Wire Gauge (mm²)                        0.75 - 6.0               1.3 - 13.3                   13.3 - 53.5           5.3 - 85.0                                                      Powerpole® Family  SECTION 2

   Number of

   Power Circuits             1 / Stackable                         1 / Stackable                1 / Stackable         1 / Stackable

   Ground                                  ●

   PCB Mount                               ●                             ●

   Busbar                                                                ●                                                          ●

   Panel Mount                             ●                             ●                          ●                               ●

   Blind Mate                 Powerpole® Pak

   Hot Plug                                ●                             ●                          ●                               ●

   Touch Safe                              ●

   Polarized Housing                       ●                             ●                          ●                               ●

   Latching                   Powerpole® Pak

   Strain Relief              Powerpole® Pak

Actual Size - Connector Half

                              ............................................................... Powerpole® Housings ..........................................................

                              PP15/45                         PP75                        PP120                        PP180

All Data Subject To Change Without Notice                                                                                     www.andersonpower.com                                    - 17 -
                              Powerful Versatility

                              - Create Your Own Custom Connector from Durable Proven Components

                              Powerpole® connectors can be easily customized to each power connection need. Choose from a wide range of

                              colored housings and stack them together into a multiple position connection.    Durable silver or tin plated contacts

                              crimp and poke into housings and are available for a broad range of wire sizes. PCB and busbar contacts can also

                              be simply snapped into place using the same housings. Pre-mate ground / power housings and contacts can be

                              used for safety or sequencing and stack along with standard housings.

                              How to Create Mating Blocks of Stacked Powerpole® Connectors

                              A Single Row Assembly such as the 1x3 shown below will mate to itself. If an assembly has more than one row

                              such as the Two Row Assembly 2x1 shown below, then a different mirror image mating assembly is required.

                              Single Row Assembly 1x3                                                                                             Two Row Assembly 2x1

SECTION 2  Powerpole® Family

                              To Create a Mirror Image Mating Assembly:

                              When mating blocks are viewed with their hoods in the respective orientation (down         or  up), the column position of

                              connectors is unchanged. The rows themselves are mirror images of each other. So           in  the below example, what

                              is column 1 on side A, is column 3 on side B.

                              Side A Hood Down                                                                                                                                  Side B Hood Up
                                         Column 1    Column 2                Column 3  Column 1      Column 2  Column 3

                                                                                       C             B            A          Hood Up

                              Hood Down  A           B                       C

                                         D           E                       F         F             E         D

                                         G           H                       I         I             H            G

- 18 -                        www.andersonpower.com                                                                          All Data Subject To Change Without Notice
Use the Same Housings for Wire, PCB, or Busbar Connections

The Powerpole® connection system allows the same housings to hold different contacts for terminating to wire,

printed circuit boards, or busbars. See some of the many ways Powerpole® components can be assembled to

create a custom connection solution.

                       

                        Wire-to-Wire

                                                                                                               Powerpole® Family  SECTION 2

                        Wire-to-PCB

                        Wire-to-Busbar

All Data Subject To Change Without Notice                   www.andersonpower.com                              - 19 -
                                  Powerpole® Connectors

                                  - PP15 to PP45 :                                                       PP15-45 series are the smallest Powerpole® housings. They can

                                  up to 55 Amps                                                          be used for wire-to-wire or wire-to-board applications. Wire sizes

                                                                                                         from #20 AWG (0.75 mm²) to #10 (6 mm²) offer power capabilities

                                                                                                         up to 55 amps per pole. Finger proof housings and the ability

                                                                                                         to incorporate first-mate last-break ground connectors enhance the

                                                                                                         capabilities of this Powerpole® series.

                                                                                                         High Power Density

                                                                                                         • Up to 55 amps in a compact footprint

                                                                                                         Wire-to Wire & Wire-to-Board Configurations

                                                                                                         • Wire & PCB contacts can be used in the same housings

           Powerpole® PP15 to 45                                                                         Finger Proof Housings Available

                                                                                                         • Protects against accidental contact with live circuits

SECTION 2                         | PP15-45 ORDERING INFORMATION |

                                  PP15-45 Finger Proof Housings                                                               PP15-45 Finger Proof & Standard & Ground

                                  Improved on the original APP design by adding ribs to mating interface to                   Housing Dimensions

                                  protect against accidental contact with live circuits. Meets the requirements

                                  o         f UL1977 s         ection 10.2 and is rated IP20. Will not mate with standard housings.         [ 7.9 ]  Front View

                                  Description  ------------ Part Numbers ------------         Finger Proof                    0.31                                    [  2  4  . 6   ]                         Mated Length

                                  Minimum Quantity ...       2,500           200   .....                                                           0.97

                                  Red          1327FP-BK              1327FP                  R         ib Feature                                   [ 7.9 ]                               [ 8.4 ]

                                  Green        1327G5FP-BK            1327G5FP                                                         0.31                                  0.33

                                  Black        1327G6FP-BK            1327G6FP                                                                           [ 41.2 ]

                                  White        1327G7FP-BK            1327G7FP                                                                                     1.62

                                  Blue         1327G8FP-BK            1327G8FP

                                  Yellow       1327G16FP-BK           1327G16FP

                                  PP15-45 Standard Housings

                                  This original housing design has an open interface and is available

                                  in a wide array of colors.  Will not mate with finger proof housings.

                                  Description  ------- Part Numbers ------

                                  Minimum Quantity  ...     2,500        200   ...               

                                  Red          1327-BK                1327                       

                                  Green        1327G5-BK              1327G5

                                  Black        1327G6-BK              1327G6

                                  White        1327G7-BK              1327G7

                                  Blue         1327G8-BK              1327G8

                                  Yellow       1327G16-BK             1327G16

                                  Orange       1327G17-BK             1327G17

                                  Gray         1327G18-BK             1327G18

                                  Brown        1327G21-BK             1327G21

                                  Pink         1327G22-BK             1327G22

                                  Purple       1327G23-BK             1327G23

                                  45A Premate Ground Housings - (for use with ground contacts                          only)

                                  Green housings are keyed to prevent accidental mating with

                                  standard or finger proof Powerpole® housings.

                                  Description  ------  Part Numbers -----

                                  Minimum Quantity  ...      2,500           200  ...

                                  Green                    1827G1-BK      1827G1

- 20 -                                         www.andersonpower.com                                                                               All Data Subject To Change Without Notice
PP15-45 Tin Plated Power Contacts                                                                                                                      Open Barrel Contact

Offer cost effective performance up to 1,500 mating cycles.  See specifications and temperature

charts for amperage ratings by wire size.

                                                                                                                                        Dimensions                                                                                 [ 3.6 ]                           [ 3.6 ]

                                                                  Mating    Loose Piece         Reeled              - A -                                                                                        0.14                           0.14

Barrel  AWG              mm²                 Force              -------- Part Numbers -------               inches    mm

Minimum Quantity  .......................................               200                  5,000       .........................                                                                              [ 17.2 ]

Open    14 to 10 K*      2.1 to 5.3          High               269G3-LPBK                   269G3          0.21      5.33                                                                     [ 6.4 ]            0.68

Open    14 to 10 K*      2.1 to 5.3          Low                261G2-LPBK                   261G2          0.20      5.08                                                                     0.25

Open    14 to 10 SF*     2.1 to 6.0          High               201G1H-LPBK                  201G1H         0.24      6.10                                                         A

Open    14 to 10 SF*     2.1 to 6.0          Low                200G1L-LPBK                  200G1L         0.24      6.10

Open    16 to 12         1.3 to 3.3          High               269G1-LPBK                   269G1          0.18      4.57

Open    16 to 12         1.3 to 3.3          Low                261G1-LPBK                   261G1          0.18      4.57

Open    20 to 16         0.52 to 1.3         High               269G2-LPBK                   269G2          0.16      4.06

Open    20 to 16         0.52 to 1.3         Low                262G1-LPBK                   262G1          0.16      4.06

K*  - For #10 AWG class K stranded wire or smaller.  For larger wires use superflex contacts.

SF*- Indicates wires with high stranding such as Super Flex.                                                                                                                                                                          Powerpole® PP15 to 45  SECTION 2

PP15-45 Silver Plated Power Contacts                                                                                                                                                     Open Barrel Contact

Maximize performance by offering up to 10,000 mating cycles and are recommended for circuit interrupt or

hot plug applications.  See specifications and temperature charts for amperage ratings by wire size.  Only closed                                                                           [ 17.27 ]

barrel contacts are suitable for soldering.                                                                                                                                                    0.68                     [  6.35 ]

                                                                                                                                                                                  Dimensions                                                                  0.25

                                               Mating                      Loose Piece                      Reeled                        -A-           - B -                                                   [ 3.81 ]     A

Barrel      AWG            mm²                 Force            ------- Part Numbers --------               Part Numbers            inches  mm                inches     mm                                     0.15

Minimum Quantity ..........................................     5,000                    200                  5,000             .................................................

Open        14 to 10 K*    2.1 to 5.3          Low              -                261G3-LPBK                 261G3                   0.20    5.08    -        -

Open        14 to 10 SF*   2.1 to 6.0          Low                    -          200G3L-LPBK                200G3L                  0.24    6.10    -        -                              Closed Barrel Contact

Open        20 to 16       0.52 to 1.3         Low                    -          262G2-LPBK                 262G2                   0.16    4.06    -        -

Closed      16 to 12       1.3 to 3.3          Low              1331-BK          1331                            -                  0.15    3.81  0.10     2.54                             [ 16.26 ]                      [ 7.35  ]

Closed      20 to 16       0.52 to 1.3         Low              1332-BK          1332                            -                  0.12    3.05  0.07     1.78                                0.64                        0.29

K*  - For #10 AWG class K stranded wire or smaller.  For larger wires use superflex contacts.                                                                                                  [ 3.81 ]     BA

SF*- Indicates wires with high stranding such as Super Flex.                                                                                                                                      0.15

45A Premate Ground Wire Contacts - (for use with ground housing only)

Tin or silver plated contacts are rated for ground or power. Hand tools are available for loose piece                                                      Open Barrel Premate Contact

contacts. Reeled contacts can be used with high volume press and applicator tooling. Tin contacts

are rated for up to 1,500 mating cycles. Silver contacts are rated up to 10,000 mating cycles.                                                             [ 3.6 ]                 [ 19.1 ]

                                                                                                                                               Reeled                                                       0.14                          0.75

                                               Mating              Loose Piece                Part                                                                                 [ 6.4 ]

                                                                                                                                                                                   0.25

Type             AWG       mm²                 Force            - Part Numbers -             - Numbers -

Minimum Quantity .............................................            200                   5,000 .....                                                                        [ 6.1 ]

Open, Tin        14 to 10  2.1 to 6.0          Low              1830G1-LPBK                   1830G1                                                                               0.24

Open, Silver     14 to 10  2.1 to 6.0          Low              1830G2-LPBK                   1830G2                                                                [ 6.1 ]

                                                                                                                                                                                   0.24

25A Right Angle PCB Contacts Tin Plated

Suitable for right angle applications up to 25A per pole. Tin plating enhances solderability.

C         annot be m         ixed with 45A PCB contacts. For mating with wire contacts only.

                                                                                                           Dimensions

            Mating                Loose Piece                           - A -                        - B -

Row         Force      ------- Part Numbers -------             inches       mm              inches      mm

Minimum Quantity ...     1,000               100                ...................................................                                        A                                                      [ 9.9 ]

Top         Low        1377G1-BK             1377G1             0.59         14.80           1.52        38.60                                                                                                    0.39

            High       1317G1-BK             1317G1

Bottom      Low        1377G2-BK             1377G2             0.29         7.20            1.36        34.50                                                                                 B

            High       1317G2-BK             1317G2

Top         Low        1377G11-BK            1377G11            0.59         14.80           1.21        30.70                                    Use mounting staples with right angle contacts

            High       1317G11-BK            1317G11                                                                                              (see accessories).

Bottom      Low        1377G12-BK            1377G12            0.29         7.20            1.01        25.70

            High       1317G12-BK            1317G12                                                                                                                   See website for PCB layout drawing.

                                       

25A Vertical PCB Contacts Tin Plated

For mating with wire contacts only.  Suitable for vertical applications                       up     to     25A  per  pole,

tin plating enhances solderability.

                                                                              Dimensions

Mating                 Loose Piece                                    -A-

Force       ---------------- Part Numbers ---------------       inches       mm

Minimum Quantity ....    1,000               100                .......................

Low                  1377G3-BK             1377G3               2.22         56.40                                                                         [ 3.1 ]

High                 1317G3-BK             1317G3               2.22         56.40                                                                         0.12                                   A

Low                  1377G4-BK             1377G4               1.76         44.70                                                                     Housing end

High                 1317G4-BK             1317G4               1.76         44.70

Low                  1377G13-BK            1377G13              1.17         29.70

High                 1317G13-BK            1317G13              1.17         29.70

All Data Subject To Change Without Notice                                                                                                                                          www.andersonpower.com                              - 21 -
                                  45A  Right Angle and Vertical PCB Contacts Tin Plated                                                               Vertical                                                                [ 36.5 ]

                                  Suitable for right angle or vertical applications up to 45A per pole. Tin plating                                                                                                            1.44
                                                                                                                                                                                                                               [ 28.6 ]
                                  enhances solderability. Right angle contacts cannot be mixed with 25A PCB
                                                                                                                                                                                                                               1.13
                                  contacts. For mating with wire contacts only.                                                     [  29.7 ]                                                                       [ 5.8 ]
                                                                                                                                                      [ 5.1 ]
                                                                                     Loose Piece                                       1.17                                                                         0.23                 [ 16.3 ]
                                                                                                                                                      0.20
                                                                                                                                       REF                                                                                               0.64
                                  Description                         ----------- Part Numbers -----------
                                                                                                                                       [ 7.9 ]                                               [ 7.9 ]                                     PP15/45 Housings
                                  Minimum Quantity     .............  1,000           100  ....................
                                                                                                                                       0.31                                                  0.31                                        (1327 Series)

                                  Vertical                            3-5911P1        1335G1                                           TYP                                                   TYP                               Right Angle Contact

                                  Right Angle Bottom Row              3-5912P1        1336G1                                           Use mounting   staples with right                  angle                                Horizontal (bottom)

                                  Right Angle Top Row                 3-5913P1        1337G1                                                                                                                                   Cat.No. 1336G1

                                                                                                                                       contacts (see  accessories).                                                 Right Angle Contact

                                                                                                                                                                                                                    Horizontal (top), Cat.No. 1337G1

                                  45A Premate Ground PCB Contacts

                                  Right angle contacts are suitable for power or ground. Use to mate with 45A                                                      [ 45.3                 ]                         [ 7.9 ]

                                  ground wire contacts. Tin plated contacts are rated up to 1,500 mating cycles.                                      [ 14.7 ]       1.78                 [ 41.2 ]                  0.31 TYP

                                  C         an be used         with other         45A PCB connectors in the bottom row.                                                    0.578                                  1.62                   [ 8.4 ]

                                                          Mating                      Loose Piece                                                                                                                   0.33 TYP

                                                                        Force             ------- Part Numbers -------                                                             [ 5.6 ]                                   Pre-mate wire

           Powerpole® PP15 to 45  Minimum Quantity     ...................   1000                 100     ....                                        [ 3.6 ]                       0.22     [ 7.9 ]           connector

                                                                                                                                                      0.14         [ 28.1                 ]           0.31

                                  PCB, Bottom Row        Low                    3-5952P1      1836G1                                                                 1.11                                      Mated Pair

SECTION 2                         | PP15-45 ULTRASONICALLY BONDED ASSEMBLIES |

                                  Assemblies feature housings that are ultrasonically welded to create a one piece connector unit using an APP special process. After welding, retaining pins are

                                  no longer required to secure the stacked housings to each other. This allows Powerpole® 15-45 connectors to be used as a durable one piece connector header.

                                  Contact customer service for configurations not shown below.  

                                  Single Row 1x2 Assemblies                                                                       

                                                                                                                                 Housings with                Housings with                               

                                                                                                                                 45A Vertical                 45A Right Angle                                             Color & Type

                                  Circuit Description                                 Housings Only                PCB Contacts                 PCB Contacts                                             Position Matrix

                                  Minimum Quantity  ................................              500                         500                           500            .....                              1             2

                                  DC 2 Wire Standard Housings                         ASMPP30-1X2-RK               ASMPV45-1X2-RK               ASMPR45-1X2-RK                                        RED / STD     BLK / STD

                                  DC 2 Wire Reverse Standard Housings                 ASMPP30-1X2-KR               ASMPV45-1X2-KR               ASMPR45-1X2-KR                                        BLK / STD     RED / STD

                                  DC 2 Wire Finger Proof                              ASMFP30-1X2-RK               ASMFV45-1X2-RK               ASMFR45-1X2-RK                                        RED / FP      BLK / FP

                                  DC 2 Wire Finger Proof Reverse                      ASMFP30-1X2-KR               ASMFV45-1X2-KR               ASMFR45-1X2-KR                                        BLK / FP      RED / FP

                                                                                 

                                  Single Row 1x3 Assemblies

                                                                                                                                 Housings with

                                                                                                                                 45A Right Angle                                 Color & Type

                                  Circuit Description                                 Housings Only                PCB Contacts                                    Position Matrix

                                  Minimum Quantity  ................................              500                     500            .....         1                     2                                   3

                                  DC 2 Wire Finger Proof with Ground                  ASMFP30-1X3-KER              ASMFR45-1X3-KER              BLK / FP       GRN / GND      RED / FP

                                  AC Single Phase Finger Proof                        ASMFP30-1X3-KEW              ASMFR45-1X3-KEW              BLK / FP       GRN / GND      WHT / FP

                                  Two Row 2x1 Assemblies

                                                                                                                                 Housings with                Housings with

                                                                                                                                 45A Vertical                 45A Right Angle                                          Color & Type

                                  Circuit Description                                 Housings Only                PCB Contacts                 PCB Contacts                                          Position Matrix

                                  Minimum Quantity  ................................              500                          500                           500            ....                            1              2

                                  DC 2 Wire Finger Proof                              ASMFP30-2X1-KR               ASMFV45-2X1-KR               ASMFR45-2X1-KR                                        BLK / FP      RED / FP

                                  DC 2 Wire Finger Proof Mate                         ASMFP30-2X1-RK               ASMFV45-2X1-RK               ASMFR45-2X1-RK                                        RED / FP      BLK / FP               

                                                                                         

                                  Two Row 2x2 Assemblies

                                                                                                                                 Housings with                Housings with                               

                                                                                                                                 45A Vertical                 45A Right Angle                                                                   Color & Type

                                  Circuit Description                                 Housings Only                PCB Contacts                 PCB Contacts                                                        Position Matrix

                                  Minimum Quantity  ................................                 500                   500                                500            .....                 1                       2          3          4

                                  AC 3 Phase, 3 Wire Finger Proof                     ASMFP30-2X2-KRWE                     N/A                                N/A                            BLK / FP               RED / FP   WHT / FP  GRN / GND

                                  AC 3 Phase, 3 Wire  Finger Proof Mate               ASMFP30-2X2-WEKR                     N/A                  ASMFR45-2X2-WEKR                             WHT / FP               GRN / GND  BLK / FP  RED / FP

                                                                                                                                       1                                            1                 2

                                       1        2                                     1           2         3                          2                                            3                 4                       Hood Up

                                  Single Row 1x2 Assembly                 Single Row 1x3 Assembly            Two Row 2x1 Assembly              Two Row 2x2 Assembly

                                  Type

                                  STD = Standard Housing           FP = Finger Proof Housing           GND = Ground Housing

- 22 -                                          www.andersonpower.com                                                                                                                                               All Data Subject To Change Without Notice
Powerpole® Pak Connectors

- PP15 to PP45                                                                                        Powerpole®             Pak                         connector   shells         enclose                   stacked

                                                                                                      groupings of PP15-45 sized housings in a durable black

                                                                                                      shell for a finished connector appearance and additional

                        Plug shell                                                                    features. Inline, panel mount, and blindmate configurations

                        with latch                                                                    are available. Plug shells offer the option of integral latches

                                                                                                      and strain relief to help secure your connection.

Snap-in                                                                                               • Package Groupings of PP15-45 Connectors

                                                                                                           Provides a finished appearance while protecting the individual

                                                          Blindmate                                        connectors with an outer shell

                                                                                                      • Inline, Panel Mount, “T” or Blindmate Configurations

                                                                                                           Allows one connection system to meet multiple needs

               T-Pak            Plug shell                                                            • Optional Latching and Strain Relief                                                                             Powerpole® Pak  SECTION 2

                                without latch                                                              Secures your connection and wires

For environmentally sealed connector shells to hold Powerpole®

15-180 connectors, see SPEC Pak® product series on our

website, www.andersonpower.com

| POWERPOLE® PAK ORDERING INFORMATION                                                                             |       Powerpole® housings and contacts are                      sold separately.

                                                                                                                          See page 20 for ordering information.

Plug Shell without Latch

Can mate inline with other plug shells with or without latches, or mate to a panel

mount receptacle. For use with Powerpole® wire connectors only. Cable Clamp                                                                                                                        [ 53.09 ]

and Hardware Pak or Retaining Pins must be ordered separately.                                                                                                       [ 21.59 ]                     2.09

                                                                                                        Dimensions                                                                                               0.85

                                                                                                              -A-

Description           -------------- Part Numbers --------------     inches     mm                                                                                                                               A

Minimum Quantity  ...    1,000                   500           25      .............................                                                     [ 49.28 ]

Black, 2-4 Poles      1461G1-BK                    -      1461G1     1.24       31.50                                                                          1.94                 Retaining Pin

Black, 5-6 Poles             -             1461G2-BK      1461G2     1.56       39.62                                                                    Side View                  Top View

Black, 7-8 Poles             -             1461G3-BK      1461G3     1.87       47.50

                                                                                                                                                         NOTE: Retaining pins are used to secure and position

                                                                                                                                                         Powerpole® housings in one of three positions in plug shells.

                                                                                                                                                         Max wire O.D. for 2-4 pole plug shells    is 0.60 inches   [15.2mm²].  

Plug Shell with Latch                                                                                                                                    For all other plug shells is 0.63 inches  [ 16.0 mm²].

Can mate inline with other plug shells without latches, or mate to a panel mount receptacle. For use

with Powerpole® wire connectors only.      Cable Clamp and Hardware Pak or Retaining Pins must

be ordered seperately.                                                                                                                                              Side View

                                                                                                                                                       Dimensions

                                                                                                                             -B-                              -C-               -D-                              [ 21.59 ]

Description                         ------------- Part Numbers --------------   inches   mm          inches         mm          inches  mm                             0.85

Minimum Quantity  ..... 1,000                   500           25       ................................................................................                        B

Black, 2-4 Poles      1460G1-BK                   -       1460G1  1.94     49.28       2.25           57.15       1.24    31.50

Black, 5-6 Poles             -             1460G2-BK      1460G2  1.94     49.28       2.25           57.15       1.56    39.62                                     Top View

Black, 7-8 Poles             -             1460G3-BK      1460G3  1.94     49.28       2.25           57.15       1.87    47.50                                                C

Black, 9-10 Poles            -             1460G4-BK      1460G4  2.51     63.75       2.82           71.63       1.84    46.74

                                                                                                                                                                                                   D

                                                                                                                                                                     Retaining Pin

All Data Subject To Change Without Notice                                                                                                                           www.andersonpower.com                               - 23 -
                           Plug Shell with Latch & Non-Conductive Strain Relief                                                                                                               [  21.5  ]

                           New 2X3 Powerpole® Pak offers an improved ergonomic shell for easier latch operation as                                                                               0.85

                           well as a plastic, non-conductive strain relief. The new strain relief can accommodate up

                           to a 6 conductor #10 AWG cable. Can mate to a panel mount receptacle. For use with

                           Powerpole® wire connectors only. Cable Clamp and Hardware Pak or Retaining Pins                                                                                                             [  81.5 ]

                           must be ordered separately.  To be used with 115G23 cable clamp only.                                            [ 73.5 ]                                                                      3.21

                                                                                                                                                                 2.90

                           Description             -------- Part Numbers -------

                           Minimum Quantity ..             1,000             25   ...               

                           Black, 5-6 Poles        1460G23-BK            1460G23                                                                                                                                                  NOTE: Max wire O.D. for

                                                                                                                                                                                                          [ 51.4 ]                1460G23 is 0.80 inches

                                                                                                                                                      [ 26.1 ]                                            2.02                    [20.3 mm²].

                           Snap-in Receptacle Shell                                                                                                   1.03

                           Mate to plug shells with or without latches, or mate to another panel mount receptacle to create a bulkhead to

                           bulkhead connection. For use with Powerpole® wire or PCB connectors.                   Order the number of retaining pins for

                           each receptacle as shown below separately.
                                                       
                                                                                                                                          Number of             Dimensions     Knock Out Size

                                                                                                                                          Retaining Pins        -E-                - Width -

           Powerpole® Pak  Description          ---------------- Part Numbers ----------------         to Order              inches  mm     inches    mm                                                                  [ 1.78 ]             [ 19.56 ]

SECTION 2                  Minimum Quantity  ...   1,000                      500                   25       ...............................................................................              [ 27.94 ]       0.07                 0.77

                           Black, 2-4 Poles     1470G1-BK                       -              1470G1  1                     1.50    38.10  1.25      31.75                                               1.10

                           Black, 5-6 Poles             -               1470G2-BK              1470G2  2                     1.88    47.75  1.62      41.15                                                                       E

                           Black, 7-8 Poles             -               1470G3-BK              1470G3  3                     2.13    54.10  1.88      47.75

                           Black, 9-10 Poles            -               1470G4-BK              1470G4  4                     2.44    61.98  2.19      55.63

                           * Height = [25.4 mm] 1.0 in.                                                                                                                                                                               Retaining Pin

                                                                                                                                                                                                 NOTE: Retaining pins are used to secure and

                           Cable Clamp & Hardware Pak                                                                                                                                            position Powerpole® housings in one of two

                           Includes cable clamp, 2 screws, and required amount of retaining pins for each configuration.                                                                         positions in receptacle shells.

                                          Screw Head              Cable

                           Description    Type                    Type               ------------ Part Numbers ------------

                           Minimum Quantity  ...................................       1,000         500            25 ...                                                                                                            Retaining Pin

                           2-4 Poles      Straight Slot           Bundled            115G1-BK          -         115G1

                           5-6 Poles      Straight Slot           Bundled            115G2-BK          -         115G2                                                                                    Cable Clamp

                           7-8 Poles      Straight Slot           Bundled            115G3-BK          -         115G3                                                                                    With Screws

                           9-10 Poles     Straight Slot           Bundled                   -   115G4-BK         115G4

                           2-4 Poles      Philips                 Bundled            115G7-BK          -         115G7                      Plug Shell Without Latch Shown

                           5-6 Poles      Philips                 Bundled            115G8-BK          -         115G8

                                                                                                                                            Shell, housing and contacts

                                                                                                                                            are sold separately.

                           Cable Clamp & Hardware Pak

                           Includes 2 cable clamp halves, 2 screws and 2 retaining pins.  To be used with

                           1460G23 Plug Shell only.                                                                                                   Screws

                                          Screw Head              Cable                                                                            Retaining

                           Description    Type                    Type               ------ Part Numbers ------                      Pins

                           Minimum Quantity     ............................……       1,000                 25

                           5-6 Poles      Philips                 Bundled            115G23-BK         115G23

                                                                                                                                           Clamp

                                                                                                                                                                                                                                      Retaining Pin

                           Flexible Conduit Clamp & Hardware Pak

                           Includes cable clamp, 2 screws, and need amount of retaining pins for each configuration.

                           Description          - Part Number -                                                                                                                                        Conduit Clamp

                           Minimum Quantity     ...... 100    ......                                                                                                                                                 With Screws

                           2-4 Poles                  110G10                                                                                      Plug Shell With Latch Shown

                                                                                                                                                  Shell, housing and contacts

                                                                                                                                                  are sold separately.

                           Retaining Pin for Snap-in Receptacle

                           Order the number of retaining pins for each receptacle shown in the Snap-in Receptacle

                           Shell ordering information. Pins are also required for the plug side when the Cable Clamp &

                           Hardware Pak is not ordered.

                           Description          ----- Part Number ------

                           Minimum Quantity     .....  1,000            100     ...                                                                                                                                 Shell and housing are

                           Retaining Pin               110G9-BK   110G9                                                                                                                                             sold separately.

- 24 -                                       www.andersonpower.com                                                                                                                                                   All Data Subject To Change Without Notice
Blindmate Pak Connector                                                                                                             [ 88.6 ]

Ideal for panel to panel, bulkhead to bulkhead, or rack mount applications that require the                               [ 76.4 ] 3.49         [ 50.8 ]     [ 36.7 ]                            [ 58.93 ]         [ 24.38 ]

power connector to compensate for up to 0.45 in. [11.43 mm] of misalignment in either axis.                                 3.01                    2.00           1.45                          2.320             0.960

Eight positions can be filled with Powerpole® 10-45 connectors. The receptacle side can be

used with wire or PCB contacts.   Hardware bag includes retaining pins.

Description                                                       ---------- Part Numbers ----------

Minimum Quantity  ....................................................        50                25  ..........     [ 5.0 ]                                         [ 3.05 ]                      [47.24]           [ 13.46 ]

2x4 Blindmate Plug Shell, Hardware & Pins                                 -             BMPP10-45P              Ø   0.20     4            [ 38.6 ]                    0.120                      1.860             0.530

                                                                                                                                          1.52

2x4 Blindmate Receptacle Shell, Hardware & Pins                           -             BMPP10-45R

2x4 Blindmate Plug Shell                                          BMHSG-P                        -                          Plug Outline                                     Receptacle Outline

2x4 Blindmate Receptacle Shell                                    BMHSG-R                        -

Hardware Bag Plug Side                                                            -     110G50                                                                                                   [ 29.14 ]

Hardware Bag Receptacle Side                                                      -     110G51                     [ 30.2 ]                                                                      1.147

                                                                                                                    1.19

                                                                                                                                    [21.5]                [  36.7  ]                                               [ 0.64 ]      Powerpole® Pak  SECTION 2

                                                                                                                                    0.85                     1.45                                                  0.025

                                                                                                                             [4.4]                                       [ 0.64 ]

                                                                                                                             0.17                                            0.025

See our innovative MARC Connector that offers straight-on or rotational blindmate capability.                                                       MARC

holds 6 PP15/45 power contacts and 2 PP15/45 premate ground contacts in a high temperature hous-

ing.  Visit our website, www.andersonpower.com to learn more.

“T” Pak 2 Way Splitter

The Powerpole® “T” Pak connector is a 2 way electrical splitter that splits electrical current from

one incoming circuit into two outgoing circuits. The standard configuration is pre-wired for AC

3 phase, 3 wire plus ground configurations. The “T” Pak can also be used for AC single phase

plus ground or DC 2 wire plus ground applications by not using either the red or white power

positions. “T” Pak is pre-wired from the factory allowing plug and play field installation

of modular office and industrial equipment. UL recognition up to 20 amps and 600 volts is

achieved when mating Powerpole® Pak plugs with #12 AWG wire.

For OEM manufacturing scale applications, the “T” Pak can be loaded with custom                                                                                                                          [ 86.2 ]

configurations of any of our finger proof, standard, or ground housings and contacts                                            [ 102.2 ]                                                                   3.39

i         n the PP15         -45 series. Contact sales or customer service for additional information.                                            4.03

Description                                      - Part Numbers -                                                                                                                                           [ 85.8 ]

Minimum Quantity   ............................  80               ........                                                                                                                                  3.38

Assembled “T” Pak                                          20-01

Mating Plug Shell with Latch 2x2                           26-01                                                                                                                                 [ 53 ]

Mating Plug Shell without Latch 2x2                        27-01                                                                                                                                 2.09

Standard configuration for each side of the T includes (1) each Red, Black, and White Standard                                      [ 43.2 ]

PP 15-45 Housings & 261G2-LPBK contacts with (1)  45A Green Premate Ground Housing and                                              1.70

1830G1-LPBK contact.                                                                                                                                                  [ 51.1 ]

                                                                                                                                                                         2.01

               

Mating plug shells include (1) each Red, Black, and White Standard PP 15-45 Housings &

(3) 261G2-LPBK contacts with (1)  45A Green Premate Ground Housing and 1830G1-LPBK

contact. Cable clamp & hardware pak also included.

                          A

                                                                                                      27 - 01                                                                           26 - 01

                                                                                                      Mates With B                                                    Mates With A & C

                              B                                                      C

All Data Subject To Change Without Notice                                                                                                           www.andersonpower.com                                                     -  25  -
                                       | PP15-45 & POWERPOLE® PAK SPECIFICATIONS |

                                       Electrical                                                                             Mechanical               

                                       Current Rating Amperes ¹                             UL 1977    CSA/TUV  Wire Size Range                              AWG                              mm²

                                       Singlepole Wire to Wire (10 AWG)                     55         40                                                    20 to 10                         0.75 to 6.0

                                         Singlepole Ground Wire to Wire or PCB (10 AWG) 45             35                      

                                         3x3 Block Wire to Wire (10 AWG)                    40         27       Max. Wire Insulation Diameter                in.                              mm

                                         Singlepole 25A PCB to Wire (12 AWG)                25         -                                                     0.175                            4.450

                                         2x3 Block 25A PCB to Wire (12 AWG)                 25         22 *                    

                                       Singlepole 45A PCB to Wire (10 AWG)                  45         40 *     Operating Temperature ²                      °F                               °C

                                         2x3 Block 45A PCB to Wire (10 AWG)                 45         25 *     Powerpole® Housings & Powerpole® Pak Shells  -4° to 221°                      -20° to 105°

                                                V           UolLta1g9e77Rating AC/DC                          6         00          MPaCtiBngtoCWycirlees No Load by Plating          S- ilver (Ag) T1,i5n0(0Sn)
                                                                                                                Wire to Wire                                 10,000                           1,500
                                       Dielectric Withstanding Voltage
                                                                                                                               
           Powerpole® PaPk15 to 45       Volts AC                                           2,200
                                                        Avg. Mating / Unmating Force                                                                                       Lbf.                             N

                                       Avg. Mated Contact Resistance Milliohms ¹                                  Low Force Wire, High Force PCB, & Ground   3                                13

                                         15A Wire Contact with 5/8” of #16 AWG              0.875                 High Force Wire                            5                                22

                                         30A Wire Contact with 5/8” of #12 AWG              0.600                 Low Force PCB                              2                                9

SECTION 2                                45A Wire Contact with 5/8” of #10 AWG              0.525                              

                                       45A PCB Contact to Contact                           0.500               Min. Contact / Spring Retention Force        Lbf.                             N

                                         25A PCB Contact to Contact                         0.600                                                            20                               90

                                                                       

                                       UL Hot Plug Current Rating Amperes 5                                     Powerpole® Pak Latch Avg. Defeat Force       Lbf.                             N

                                         250 cycles at 72V DC                               45A                                                              150                              667

                                         250 cycles at 120V DC                              30A                                

                                                        PCB Specifications               
                                       UL Ground Short Time Current Test - 45A Premate Ground
                                                                                                                Mounting Style                               Plated Through Hole
                                       750 Amps, #10 AWG Wire                               4 Seconds
                                                                                                                  PCB Thickness- in. [mm]                    0.090 - 0.150                    (2.3-3.8)
                                         470 Amps, #12 AWG Wire                             4 Seconds
                                                                                                                  25A PCB Recommended Traces                 #12 AWG Cross Section

                                                                                                                45A PCB Recommended Traces                   #10 AWG Cross Section

                                       Materials                                                                               

                                       Housing                                                                  Mechanical Shock 4

                                                                                                                  MIL-STD-202                                213 Condition A                  50g’s

                                       Plastic Resin                         Polycarbonate

                                       Contact Retention Spring              Stainless Steel                    Vibration High Frequency 4

                                       Housing Flammability Rating                                                MIL-STD-202                                204 Condition A                  10g’s

                                         UL94                                V-0

                                       Glow Wire                             825°C (GWFI) / 800°C (GWIT)

                                       Contact

                                       Base                                  Copper Alloy

                                       Plating                               Tin or Silver

                                       Contact Termination Methods

                                       Crimp ³                               Wire Contacts

                                         Hand Solder                         1331, 1332 & PCB Contacts

                                       Solder Dip                            PCB Contacts

                                       Wave Solder                           PCB Contacts

                                       NOTE 1: See IEC 60664-1 for working voltage.

                                       NOTE 2: Amp ratings are stated per position and based on all positions being fully loaded.

                                       * No TUV Recognition

                                       1 Based on: 105°C rated or better cable of the largest size, Properly calibrated APP recommended     tooling, and  a 25°C ambient temperature. UL rating not

                                         to exceed the maximum operating temperature. CSA rating below a 30°C temperature rise.

                                       2 Limited by the thermal properties of the connector plastic housing.

                                       3 Use APP recommended tooling only. Alternate tools may adversely affect the performance of our      connectors    along with UL and CSA recognition.

                                       4 Tested with contact part number 261G2.

                                       5 Based on 2 housings blocked together.

-          26                       -                 www.andersonpower.com                                                                                       All Data Subject To Change Without  Notice
|  IEC INFORMATION |

   Connector                                         Creepage /           Material     Connector                                      Creepage /            Material
                                                                                                                                      Clearance
   Series       Configurations                       Clearance            Group        Series            Configurations               per IEC 60950-1       Group
                                                     per IEC 60950-1

                Single Pole                Unmated   1.64   mm                                           Single Pole         Unmated  1.64 mm

                                           Mated     1.64   mm                                                               Mated    4.20 mm

                Stacked Powerpole ®        Unmated   1.64   mm                                           Stacked Powerpole®  Unmated  1.64 mm

   PP15/45                                 Mated     1.64   mm            IIIa         PP15/45                               Mated    4.20 mm               IIIa

   Standard                                                                            Finger Proof

                PCB - 25A                  Unmated   1.64   mm                                           PCB - 25A           Unmated  1.64 mm

                                           Mated     1.64   mm                                                               Mated    2.90 mm

                PCB - 45A                  Unmated   1.39   mm                                           PCB - 45A           Unmated  1.39 mm

                                           Mated     1.39   mm                                                               Mated    1.39 mm

   Attributes *                                      PP45                                                PP45 FP                                                      Powerpole® PaPk15 to 45  SECTION 2

   AMP Rating AC/DC                                  45                                                  45 Amp

   Voltage Rating AC/DC      (Steady State)          160 V AC/DC ( Operational)                          400 V AC/DC ( Operational)

   Breaking Capacity -AMP Rating /Cycles             30 Amp /  10 Cycles                                 30 Amp /  10 Cycles

   Voltage Rating    (Breaking Capacity)             220 VDC                                             220 VDC

   FINGER Safety - Mated only                        IEC 60529 - IP20                                    IEC 60529 - IP20 *

   Wire Size tested                                  6 mm²                                               6 mm² (10AWG)

   Contact Series Tested                             200G3L                                              200G3L

   Climatic Testing (Cold,Heat & MFG)                IEC 60512 Test  -11j, 11i & 11g,                    IEC 60512 Test  -11j, 11i & 11g

   Cycle Life                                        IEC 60512 Test 9a - 5000 Cycles                     IEC 60512 Test 9a - 5000 Cycles

   Mechanical Strength    Impact                     IEC 60512-5 @ 29.5 Inches - dropped       8  times  IEC 60512-5 @ 29.5 Inches - dropped      8  times

   Temperature Range                                 -20 °C to 105 °C                                    -20 °C to 105 °C

                                                     -4 °F to 221 °F                                     -4 °F to 221 °F

   * In mated and unmated condition

   Protection

   Touch Safety with Finger Proof Housings        &  Wire

   Contacts or PCB Mating Interface

     UL1977 Sec. 10.2     Pass

     IEC 60950            Pass

     IEC 60529            IP20

   Touch Safety With Standard Housings

     IEC 60529            IP10

   NOTE 3:  Refer to the Constructional Data form for additional information on our website., www.andersonpower.com

All Data Subject To Change Without Notice                                                                                    www.andersonpower.com                    - 27 -
                                  | PP15-45 TEMPERATURE CHARTS | Temperature rise charts are based on a 25°C ambient temperature.

                                  For                                   Temperature Rise Above 60°C, Consult the Extended                             Temperature Rise Charts in the Appropriate Product                                Section                                 on  the Website.

                                                                                                 PP15-45 Singlepole                                                                                 PP15-45 Multipole                                                                                PP25 PCB

                                                                                      Temperature Rise at Constant Current                                                                  Temperature Rise at Constant Current                                                         Temperature Rise at Constant Current

                                                                        60                                                                                                60                                                                                                    60

                                                    Above Ambient (°C)  50                                                                                                50                                                                                                    50

                                  Temperature Rise                      40                                                          Temperature Rise  Above Ambient (°C)  40                                                              Temperature Rise  Above Ambient (°C)  40

                                                                        30                                                                                                30                                                                                                    30

                                                                        20                                                                                                20                                                                                                    20

                                                                        10                                                                                                10                                                                                                    10

           Powerpole® PP15 to 45                                                                                                                                                0                                                                                               0

                                                                                0                                                                                                     0         10      20             30         40                                                0    5  10       15   20   25       30       35  40

                                                                                   0     10      20      30      40      50    60                                                                   Amperes Applied

                                                                                                     Amperes Applied                                                                                                                                                                                 Amperes Applied

                                                                                         10 AWG          12 AWG          14 AWG                                                             10 AWG      12 AWG             14 AWG                                                        Singlepole       2-Pole            Multipole

SECTION 2                                                                                16 AWG          18 AWG          20 AWG                                                             16 AWG      18 AWG             20 AWG

                                  Current                                          - Temperature Derating per IEC 60512-5-2 Test    5B

                                                                                                 PP15-45 Singlepole                                                                                 PP15-45 Multipole                                                                                PP25 PCB

                                                            125                          Derating vs. Ambient Temperature                                     125                           Derating vs. Ambient Temperature                                                             Derating vs. Ambient Temperature

                                                                                                                                                                                                                                                                    125

                                  Ambient Temperature (°C)  100                                                                     Ambient Temperature (°C)  100                                                                         Ambient Temperature (°C)  100

                                                                        75                                                                                    75                                                                                                                75

                                                                        50                                                                                    50                                                                                                                50

                                                                        25                                                                                    25                                                                                                                25

                                                                                   0     10      20  30      40      50  60    70                                                  0        10      20      30           40       50                                                0    5  10       15   20   25       30       35  40

                                                                                                     Amperes Applied                                                                                Amperes Applied                                                                                  Amperes Applied

                                                                                         10 AWG          12 AWG          14 AWG                                                             10 AWG      12 AWG             14 AWG                                                        Singlepole       2-Pole            Multipole

                                                                                         16 AWG          18 AWG          20 AWG                                                             16 AWG      18 AWG             20 AWG

                                  For Temperature Rise Above 60°C, Consult the Extended Temperature                                                                                         Rise Charts in the Appropriate Product Section                                      on  the  Website.

                                  Current - Temperature Derating per IEC 60512-5-2 Test 5B

                                                                                                     PP45 PCB                                                                                           PP45 PCB

                                                                                60       Temperature Rise at Constant Current                                                               Derating vs. Ambient Temperature

                                                                                                                                                                                125

                                                            Above Ambient (°C)  50                                                                    Ambient Temperature (°C)

                                  Temperature Rise                                                                                                                              100

                                                                                40

                                                                                30                                                                                              75

                                                                                20

                                                                                                                                                                                50

                                                                                10

                                                                                   0                                                                                            25

                                                                                      0      10      20  30      40      50    60                                                        0  10      20  30  40         50     60      70

                                                                                                     Amperes Applied                                                                                    Amperes Applied

                                                                                         Singlepole          2-Pole      Multipole                                                          Singlepole      2-Pole           Multipole

                                  NOTE: PP25 PCB charts based on 0.002 in² foil on board side, mated to #12 AWG conductor on wire side.  PP45 PCB charts based on                                                                                                                                    #10  AWG

                                  equivalent copper foil on board side, mated to #10 AWG conductor on wire side.

- 28 -                                                                                   www.andersonpower.com                                                                                                                                                                              All Data Subject To Change  Without  Notice
| POWERPOLE® 15-45 ACCESSORIES |

Mounting Wing

Secure dovetailed Powerpole® 15-45 series housings by passing fasteners through the wings

in either a horizontal or vertical orientation. Useful for sheet metal panels, printed circuit boards,

and many other mounting surfaces. Fasteners not included.                                      

                                                                                                                                                               Mounting                                   Wings

Description           ------- Part Numbers -------                                                                                [ 4.6 ]

Minimum Quantity  ...    2,500                  100  ....                                                                                       0.18 SQ

Red                   1399G9-BK             1399G9

Blue                  1399G8-BK             1399G8                                                                                          [ 7.9 ]

                                                                                                                                            0.31

                                                                                                                                  [ 16.7 ]

                                                                                                                                  0.66

Spacer                                                                                                                                                                                                           Powerpole® PP15 to 45  SECTION 2

Used to separate housings under high power to minimize derating. They are

recommended for squaring off a block of Powerpole® 15-45 housings for use in connector shells

and mounting clamps. Use a combination of long and short spacers opposite each other in a

mated block to add keying features or use two short spacers to avoid interference. Spacers with

holes can also be used to fasten the blocked housings to a surface with a fastener.

Description           ------ Part Numbers -------

Minimum Quantity  .....       2,500            100  .....

Red, Short w/ Hole    1399G1-BK             1399G1

Red, Long             1399G2-BK             1399G2

Red, Short            1399G6-BK             1399G6                                   [ 7.9 ]                                                [ 7.9 ]                                     [ 7.9 ]

Black, Long           1399G10-BK            1399G10                                  0.312                                                  0.312                                       0.312

Blue, Short           1399G13-BK            1399G13                                                                                                  [ 24.6 ]

White, Short w/ Hole  1399G14-BK            1399G14                [ 16.6 ]                                                       [ 16.6 ]           0.968

White, Long           1399G17-BK            1399G17                0.655                                                          0.655

                                                                   Short with Hole                                Short                     without Hole                          Long

Retaining Pins

Keep stacked Powerpole® 15-45 series housings from separating. Retaining pins are inserted in

the circular opening between two housings stacked side by side.

                                                                                                                    Dimensions

                                                                                       -A-                       -B-

Description                         ----- Part Numbers -----      inches                              mm                              inches  mm

Minimum Quantity ...  1,000                 100     ............................................................................

1 Block High          H1507P38             110G16   0.093 / 0.103  2.360 / 2.62      0.250   6.350

2 Block High          111812P5             110G17   0.093 / 0.103  2.360 / 2.62      0.440   11.180

                                                                                                                                            B

                                                                                                                                                     A

Mounting Clamp

Mounting clamps can be used for fastening a block of Powerpole® 15-45 series

housings to a panel. Connector blocks must be a complete square for the clamps

to work properly. Fastening hardware not included.

Description           -- Part Numbers --

Minimum Quantity  ... 100 sets of 2  .....

2 or 4 Pole               1462G1

3 or 6 Pole               1462G2

4 or 8 Pole               1462G3                                                                                                            2 or 4 Pole           3 or 6 Pole                4 or 8 Pole

All Data Subject To Change Without Notice                                                                                                      www.andersonpower.com                                             - 29 -
                                  PCB Mounting Staples

                                  PCB staples are soldered into place to secure Powerpole® 15-45 series housings

                                  in a horizontal configuration to the board. Reduce strain on soldering joints during

                                  mating and unmating.

                                                                                                               Dimensions                                                    A

                                  Part                                                                    -A-                -B-

                                  Numbers         H x W        Length        inches       mm    inches       mm

                                  Minimum Quantity        100  ................................................................................

                                  114555P1         1 x 1       Short      0.47            12.0  0.28         7.0

                                  114555P2       1x2           Short      0.47            12.0  0.57         14.5                                                           B

                                  114555P3       1x3           Short      0.47            12.0  0.89         22.5

                                  114555P7       1x4           Short      0.47            12.0  1.20         30.5

                                  114555P10      2x1           Short      0.79            20.0  0.28         7.0

                                  114555P6       2x2           Short      0.79            20.0  0.57         14.5

                                  114555P9       2x2           Long       0.91            23.0  0.57         14.5

SECTION 2  Powerpole® PP15 to 45  Retention Clip

                                  Retention clips prevent Powerpole® 15-45 blocks from unintended disconnects.

                                  They feature a tab for easy insertion and removal.

                                  Description             -- Part Number --

                                  Minimum Quantity ........    100        .........                       

                                  1 Block High                 110G68

                                                 

                                  Block Lok

                                  Block locks secure mated Powerpole® 15-45 series housings together. For use in

                                  h         igh vibration or shock applications wh         ere connectors are unmated infrequently.

                                  Description             - Part Numbers -

                                  Minimum Quantity ..........        100  .........                                                                     2 Pole                           4 Pole      

                                  2 Pole, Black                  110G21

                                  4 Pole, Black                  110G12                                                                          Shown  without Powerpoles  Shown with                  Powerpoles

                                                 

                                  Splash Boot

                                  Splash boots protect a 2x2 block of any combination of Powerpole® 15-45 series

                                  housings and feature snip off sealed ends for flexibility in wire O.D. Designed for

                                  through panel or inline applications. Not a hermetic seal.

                                  Description             - Part Numbers -

                                  Minimum Quantity  ........     25  ...........

                                  Female, Black                1441G1

                                  Male, Black                  1442G1

                                  For environmentally sealed connector shells to hold Powerpole®

                                  15-180 connectors, see SPEC Pak® product series on our

                                  website, www.andersonpower.com

- 30 -                                           www.andersonpower.com                                                                                                      All Data Subject To Change Without      Notice
                                           | NOTES |

                                                                             Powerpole® PP15 to 45  SECTION 2

All Data Subject To Change Without Notice             www.andersonpower.com  - 31 -
                            Powerpole® Connectors

                            - PP75: up to 120 Amps

                                                                                                                PP75 series Powerpole® housings can be used for wire-to-wire,

                                                                                                                wire-to-board,      and          wire-to-busbar             applications.      Wire      sizes

                                                                                                                from  #16  AWG      (1.3          mm²)  to    #6  (13.3            mm²)        offer     power

                                                                                                                capabilities up to 120 amps per pole. Locking housings offer

                                                                                                                the capability to secure Powerpole® housings to each other

                                                                                                                and   to  mounting        pads.   Housings                   made        from  chemical

                                       PP75 with                                                                resistant (CR) resin withstand industrial solvents better than

                                       Mounting Wings                                                           standard housings.

                                                                                                                • Large Wire Range Accommodates up to #6 (10mm²) Wire

                                                                                                                Reducing bushings allow as small as #16 (1.5 mm²) wire to be used

                                                                                                                • Wire, PCB, and Busbar Contacts

           Powerpole® PP75                                                                                      Allows one connection system to meet multiple needs

SECTION 2                                                                                                       • Mini-Powerclaw PCB Contacts Minimize PCB Footprint

                                                                                                                Removes the PP75 housing from the board side

                               | PP75 ORDERING INFORMATION |

                               PP75 Standard Housings               

                               The second smallest Powerpole® housing can be used with wire           contacts

                               up to 6 AWG [10mm²]  as well as PCB and busbar contacts.

                               Description            ------- Part Numbers --------                                       [ 15.9 ]

                               Minimum Quantity  ...   1,000             100  ......                                      0.62                          [ 47.9 ]

                               Red                    5916G7-BK      5916G7                                                                             1.88

                               Green                  5916G6-BK      5916G6

                               Black                  5916G4-BK      5916G4                                                         [ 15.9 ]                                                   [ 17.0 ]

                               White                  5916G5-BK      5916G5                                                         0.62                                                       0.67

                               Blue                   5916-BK        5916                                                                                         [ 81.3 ]

                               Yellow                 5916G15-BK     5916G15                                                                                      3.20

                               Orange                 5916G14-BK     5916G14                                          Front View                Mated Length

                               Gray                   5916G16-BK     5916G16

                                              

                               PP75 Chemical Resistant (CR) Housings               

                               Has the same form and dimensions of the standard

                               PP75 housing in a chemical resistant PBT/ PC blend                                                   Material ID   V0 = Standard

                               housing.  Suitable for use to -40°C.                                                                 Located Here  P = Chemical Resistant

                               Description             - Part Numbers -

                               Minimum Quantity  ...   1,000         .......

                               Red                     P5916G7-BK

                               Black                   P5916G4-BK

                               White                   P5916G5-BK

                               Blue                    P5916-BK

                                              

                               PP75 Locking Dovetail Housings               

                               Offers dovetails for stacking housings that have a locking feature to

                               prevent housings separating. Can mate to standard and chemical

                               resistant housings, but cannot be stacked with them.

                               Description             ---------- Part Numbers -----------

                               Minimum Quantity  ....  1,000                         100  .....

                               Red                     75LOKRED-BK            75LOKRED                                                                                             [ 47.9 ]

                               Green                   75LOKGRN-BK            75LOKGRN                                                                                             1.88

                               Black                   75LOKBLK-BK            75LOKBLK

                               White                   75LOKWHT-BK            75LOKWHT

                               Blue                    75LOKBLU-BK            75LOKBLU

                               Gray                    75LOKGRA-BK            75LOKGRA

-          32               -               www.andersonpower.com                                                                                                       All  Data  Subject To  Change  Without  Notice
PP75 Premate Ground Housings                       

Offers a first-mate, last-break connection when stacked together with PP75                                                            Mated Length

housings. Stacks together with PP75 standard and chemical resistant housings.

Housings are mechanically keyed to prevent cross mating with power positions.               

                                                                                                                                                    [ 83.1 ]

Description                                ------- Part Numbers -------                                                                                                        3.20

Minimum Quantity....               1,000           100    ...

Green                        5927G6-BK           5927G6

PP75 Silver Plated Wire Contacts

Silver plated contacts offer the best electrical performance and durability up to

10,000 mating cycles. See reducing bushings in accessory section for smaller wires.                                                                                                                Powerpole® PP75  SECTION 2

                                        Dimensions

                             Mating                   Loose Piece                  - A -

AWG            mm²           Force               -- Part Numbers --        inches         mm                      [ 11.1 ]            [ 30.0 ]

Minimum Quantity       ........................  1,000      100            ........................               0.44                      1.18

6              13.3          Low                 1307-BK    1307           0.22           5.59                    A

6              13.3          High                5900-BK    5900           0.22           5.59                    [ 7.2 ]                                                    [ 7.1 ]

8              8.4           High                5952-BK    5952           0.19           4.83                    0.28                                                       0.28

12 to 10       3.3 to 5.3    Low                 5953-BK    5953           0.14           3.56

12 to 10       3.3 to 5.3    High                5915-BK    5915           0.14           3.56

PP75 Premate Ground Wire Contacts

Silver plated contacts for use with the PP75 Premate Ground                       Housing. Rated to                                   [ 32.0 ]

10,000 mating cycles.                                                                                                                 1.26

                                                                                                                                          Dimensions                                                                   "A"

                                                         Loose Piece                     - A -                                                  [ 11.9 ]
                                                                                                                                                  0.47
Type           AWG           mm²                 ----- Part Numbers -----         inches        mm

Minimum Quantity ........................        1,000                           100            ........................

Individual     6             13.3                1875G1-BK       1875G1           0.22       5.59                 [ 7.1 ]                                      [ 7.2 ]

Individual     8             8.4                 1875G2-BK       1875G2           0.19       4.83                 0.28                                         Ø  0.28

Individual     12 to 10      3.3 to 5.3          1875G3-BK       1875G3           0.14       3.56

PP75 Silver Plated Busbar Contacts

Provide a quick disconnect input or output busbar connection. Busbar contacts are

for mating with wire contacts only. Part number 75BBS includes lock nuts. Locknuts

m         ust be ord         ered separately for B01915P1.                                                                         See Busbar contact drawing on

                Mating                                                                                                                                                                    [ 17.1 ]

Type           Thread        Force        ------------- Part Numbers --------------                                  website for further detail.                             0.68

Minimum Quantity  .................     1,000                20                10  ...

Busbar         #10-24        High         B01915P1            -            75BBS                                                                      [ 2.0 ]

Lock Nut       #10-24           -         H1216P8         110G54               -                                                                      0.08

                                                                                                                                            [ 69.1 ]

                                                                                                                                                2.72

55A     Right Angle Standard Powerclaw PCB Contacts

Standard Powerclaw contacts are for use inside a PP75 housing and

provide a color coded right angle connection to the PCB.

Description               --- Loose Piece Part Numbers --                                            [ 5.2 ]                                [ 17.0 ]                         PP75     Housing

Minimum Quantity         ..        500              100     ........                                        0.20                                0.67

Tin Plated               PC5930T-BK              PC5930T                                             [ 22.2 ]

Silver Plated            PC5930S-BK              PC5930S                                             0.87

                                                                                                                            [ 48.0 ]                                                  Standard

                                                                           See PCB contact                        [ 66.0 ]  1.89                                                      Powerclaw

                                                                           drawing on website                     2.60                                            [ 32.8 ]            Contact

                                                                           for further detail.                                                                    1.29

                                                                                                                  Second housing and contact

                                                                                                                  in two pole version only.

All Data Subject To Change Without Notice                                                                                                             www.andersonpower.com                     -  33  -
                                                 55A Right Angle Mini Powerclaw PCB Contacts                                                                                                                                                 [ 8.1 ]                                                                        [ 12.19   ]

                                                 Right angle Mini Powerclaw contacts can be used on the PCB edge                                                                                              [ 58.4 ]                               0.32                                           [ 24.6  ]                  0.480

                                                 without a PP75 housing on the PCB side. A self polarizing design only                                                                                        2.30            [ 15.6 ]                                                               0.97

                                                 allow PP75 wire housings to mate to PCB contacts one way.                                                                                                                        0.61       [ 7.6 ]

                                                                                                                       Loose Piece                                                                                                                         0.30

                                                                                                                                                                                                                                             [ 2.42 ]                                                                                     [ 25.4 ]

                                                 Description                                    -------- Part Numbers --------                                                                                                               0.095                                                               [  17.5 ]                1.00

                                                 Minimum Quantity                               ...  1,000           100    ......                                                                                                           [ 6.10 ]                                                               0.69                         [ 1.27 ]

                                                 Tin Plated                                          PC5934T-BK      PC5934T                                                                                                                         0.240                                                                                       0.050

                                                 Silver Plated                                       PC5934S-BK      PC5934S

                                                 55A Vertical Mini Powerclaw PCB Contacts                                                                                                                                                                                                                                 [ 6.25 ]

                                                 Vertical Mini Powerclaw contacts save space by not                                                                                                                                                                                        [ 12.2 ]                       0.246

                                                 requiring a PP75 housing on the PCB side. The guide                                                                                                                                                                                           0.48

                                                 housing is required for 2 pole applications to provide a                                                                                                                     [ 24.3 ]

                                                 polarized connection.                               (See PP75 accessories).                                                                                                  0.96

                                                                                                         Loose Piece                                                                                                               [ 9.7 ]   [2.32]

           Powerpole® PP75                       Description                                    --------- Part Numbers -------                                                                                                     0.38      0.091                                                                   [ 1.27 ]

                                                                                                                                                                                                                                                                                                                     0.050

SECTION 2                                        Minimum Quantity ...                                1,500           100    ......                                                                                                                                                            [ 10.29 ]              [ 4.98 ]

                                                 Tin Plated                                     PC5933T-BK           PC5933T                                                                                                                                                                   0.405                 0.196

                                                 Silver Plated                                  PC5933S-BK           PC5933S

                                                                                                                                                                                                                          See PCB contact drawing on website                                                for  further detail.

                               | PP75 TEMPERATURE CHARTS |                                                                                                                                    Temperature rise charts are based on a 25°C ambient temperature.

                                                         Current - Temperature Derating per IEC 60512-5-2 Test 5B

                                                                                                PP75 Singlepole                                                                                           PP75 Multipole                                                                                        Mini Powerclaw

                                                         125                        Derating vs. Ambient Temperature                                               125                        Derating vs. Ambient Temperature                                                                      Derating vs. Ambient Temperature

                                                                                                                                                                                                                                                                       125

                               Ambient Temperature (°C)  100                                                                             Ambient Temperature (°C)  100                                                                       Ambient Temperature (°C)  100

                                                         75                                                                                                        75                                                                                                  75

                                                         50                                                                                                        50                                                                                                  50

                                                         25                                                                                                        25                  0      10  20  30  40  50  60      70  80  90    100                            25

                                                                                 0      20      40       60      80  100        120                                                                                                                                                           0     10  20  30   40  50     60    70  80  90 100110

                                                                                                Amperes Applied                                                                                           Amperes Applied                                                                                        Amperes Applied

                                                                                            6 AWG                    8 AWG                                                                            6 AWG               8 AWG                                                                             Singlepole                  2-Pole

                                                                                            10 AWG               12 AWG                                                                               10 AWG              12 AWG

                               For Temperature Rise Above 60°C, Consult the Extended Temperature Rise Charts in the Appropriate Product Section on the Website.

                                                                                    PP75 Singlepole Loose Piece Contact                                                                       PP75 Multipole Loose Piece Contact                                                                                 Mini Powerclaw

                                                                             60     Temperature Rise at Constant Current                                                                      Temperature Rise at Constant Current                                                                  Temperature Rise at Constant Current

                                                                                                                                                                                       60                                                                                                  60

                                                         Above Ambient (°C)  50                                                                                    Above Ambient (°C)  50                                                                                                  50

                               Temperature Rise                              40                                                          Temperature Rise                              40                                                    Temperature Rise          Above Ambient (°C)  40

                                                                             30                                                                                                        30                                                                                                  30

                                                                             20                                                                                                        20                                                                                                  20

                                                                             10                                                                                                        10                                                                                                  10

                                                                             0                                                                                                         0                                                                                                   0

                                                                                 0  10  20  30  40   50  60  70  80  90 100 110     120                                                    0  10      20  30  40  50    60    70   80   90                                                       0   10     20   30  40     50      60    70     80  90

                                                                                                Amperes Applied                                                                                           Amperes Applied                                                                                        Amperes Applied

                                                                                                6 AWG                8 AWG                                                                            6 AWG                 8 AWG                                                                           Singlepole                   2-Pole

                                                                                            10 AWG               12 AWG                                                                               10 AWG              12 AWG

                               NOTE: Powerclaw charts are based on #8 AWG equivalent copper foil on board side, mated to #6 AWG conductor on wire side.

-          34               -                                                               www.andersonpower.com                                                                                                                                                                                        All Data Subject To Change Without Notice
| PP75 SPECIFICATIONS |

Electrical                                                                              Mechanical               

Current Rating Amperes ¹                        UL 1977      CSA          Wire Size Range                        AWG                                  mm²

  Wire to Wire (6 AWG)                          120          70             Wire Contacts with Bushings          16 to 6                              1.3 to 13.3

Wire to PCB (6-AWG)                             55           50                          

Wire to Busbar (6 AWG)                          75                                      Max. Wire Insulation Diameter          in.                                  mm

                                                                                                                 0.437                                11.100

Voltage Rating AC/DC                                                                                   

  UL 1977                                       600                       Operating Temperature ²                °F                                   °C

                   Standard & Ground                                                                                           -4° to 221°                          -20° to 105°

PCB Connector Recommended Voltage 3                                                       Chemical Resistant*                  -40 to 221°                          -40° to 105°

per IEC 60950-1 Table 2L Pollution Degree 2                                             *Chemical resistant material not available for PCB guide housings               

  Mini Vert. Contact Adjacent Poles             220                                      

  Mini Horiz. Contact Adjacent Poles            200                       Mating Cycles No Load by Plating       Silver (Ag)                          Tin (Sn)                  Powerpole® PP75  SECTION 2

  Standard Contact Adjacent Poles               635                       Wire and PCB Contacts                  10,000                               1,500

                                

Dielectric Withstanding Voltage                                                         Avg. Mating / Unmating Force           Lbf.                                 N

  Volts AC                                      2,200                       Wire to Wire Low Force Contacts      5                                    22

                   Wire to Wire High Force Contacts                                                                            7                                    31

Avg. Mated Contact Resistance Milliohms ¹                                                 Standard Powerclaw to Wire           7                                    31

  Wire Contact with 1 1/4” of #6 AWG            0.200                     Mini Powerclaw to Wire                 4                                    17

PCB Contact to Contact                          0.500                                    

                 PCB Specifications               

UL Hot Plug Current Rating Amperes - 250 cycles at 120V DC 6              Mounting Style                         Plated Through Hole

Wire- wire                                      50A                         Max PCB Thickness- in. [mm]          Standard: 0.15 [0.381]  

PCB- wire (Vertical Mini Powerclaw)             40A                                                              Mini:        0.25 [0.635]

                                                                          Recommended Traces                     #8 AWG Cross Section

UL Ground Short Time Current Test - 75A Premate Ground                                   

  1530 Amps, #6 AWG Wire                        6 Seconds                 Min. Contact / Spring Retention Force  Lbf.                                 N

                                                                            Wire Housing                         50                                   222

Materials                                                                                

Housing                                                                   Min. Creepage / Clearance Distance PCB in.                                  mm

Standard Plastic Resin                     Polycarbonate                    Standard Powerclaw Adjacent Poles    0.260                                6.6

Chem. Resistant Resin                      Polycarbonate / PBT blend        Mini Vert. Powerclaw Adjacent Poles  0.087                                2.2

Contact Retention Spring                   Stainless Steel                  Mini Horz. Powerclaw Adjacent Poles  0.079                                2.0

Housing Flammability Rating                                               Mechanical Shock 5

  UL94                                     V-0                              MIL-STD-202                          213 Condition A                      50g’s

  Glow Wire                                960°C (GWFI) / 800°C (GWIT)

                                                                          Vibration High Frequency 5

Contact                                                                     MIL-STD-202                          204 Condition A                      10g’s

Base                                       Copper Alloy

Wire Plating                               Silver

PCB Plating                                Sn or Ag over Ni

Contact Termination Methods

Crimp 4                                    Wire Contacts

Hand Solder                                Wire and PCB Contacts

Solder Dip*                                PCB Contacts

Wave Solder*                               PCB Contacts

Wrench / Socket                            Busbar Contacts

NOTE 1: See IEC 60664-1 for working voltage.

NOTE 2: Amp ratings are stated per position and based on all positions being fully loaded.

¹ Based on: 105°C rated or better cable of the largest size, Properly calibrated APP recommended  tooling, and a 25°C ambient temperature. UL rating      not  to  exceed  the

maximum operating temperature. CSA rating below a 30°C temperature rise.

² Limited by the thermal properties of the connector plastic housing.

³ Without use of spacers to increase creepage and clearance distances.

4 Use APP recommended tooling only. Alternate tools may adversely affect the performance of our   connectors along with UL and CSA recognition.

5 Tested with contact part number 5900.

6 Based on 2 housings blocked together.

All Data Subject To Change Without Notice                                                                        www.andersonpower.com                                     -    35  -
                            | IEC INFORMATION |

                            Connector                                      Creepage /           Material
                                                                           Clearance
                            Series      Configurations                     per IEC 60950-1
                                                                                                Group

                                        Single Pole               Unmated  2.97 mm

                            PP75                                  Mated    2.97 mm              IIIa

                                        Stacked Powerpole®        Unmated  2.97 mm

                                                                  Mated    2.97 mm

                            Attributes                                                          PP75

                            AMP Rating AC/DC                               75

                            Voltage Rating AC/DC   (Steady State)          250 V AC/DC ( Operational)

                            Breaking Capacity -AMP Rating /Cycles          75 Amp /  10 Cycles

                            Voltage Rating   (Breaking Capacity)           220 VDC

                            FINGER Safety - Mated only                     IEC 60529 - IP20

           Powerpole® PP75  Wire Size tested                               16 mm²

SECTION 2                   Contact Series Tested                          5900

                            Climatic Testing (Cold,Heat & MFG)             IEC 60512 Test  -11j, 11i & 11g,

                            Cycle Life                                     IEC 60512 Test 9a - 5000 Cycles

                            Mechanical Strength  Impact                    IEC 60512-5 @ 29.5 Inches - dropped  8  times

                            Temperature Range                              -20 °C to 105 °C

                                                                           -4 °F to 221 °F

                            Protection

                            Touch Safety with Wire Contacts

                              IEC 60529          IP10

                            NOTE 3:  Refer to the Constructional Data form for additional information on our website., www.andersonpower.com

- 36 -                                  www.andersonpower.com                                                                                 All Data Subject To Change Without Notice
| POWERPOLE® PP75 ACCESSORIES |

Strain Relief Grommets

Use for strain relief in the back side of a PP75 housing. Wire gauge given for

reference only, use grommet ID and wire OD to determine suitability in the

end application.                       

                                                                Dimensions

                                                                                  -A-                                                                        A

Description             - Part Numbers -          inches mm

Minimum Quantity   ...  100                       .......................               

#6 AWG, Black              114411P2                    0.35    8.89

#8 AWG, Black              114411P1                    0.25    6.35

#10 - 12 AWG, Black        114411P3                    0.17    4.32

Mounting Wing for Standard or CR Housings                                                                                    [ 27.4 ]                               [ 27.4 ]

Mounting wings can be used to secure dovetailed Powerpole® 75 series housings                                                    1.08                                   1.08

by passing fasteners through the wings in either a horizontal or vertical orientation.                                 [ 15.9 ]                               [ 15.9 ]                      Powerpole® PP75  SECTION 2

Useful for sheet metal panels, printed circuit boards, and many other mounting                                         0.63                                   0.63

surfaces. Fasteners not included.                                                                                      [ 15.9 ]                               [ 15.9 ]

                                                                                                                       0.63                                   0.63

Description             ------- Part Numbers -------

Minimum Quantity   ...  1,000                     100        ...               

Blue, Round Hole        1399G20-BK                1399G20

Blue, Oval Hole         1399G7-BK                 1399G7

Mounting Wing for Locking Housings

Mounting wings can be used to secure Powerpole® 75 series housings with                           [ 2.6 ]                                                  [ 5.1 ]

locking dovetails by passing fasteners through the wings in either a horizontal or                R  0.10                                                  Ø  0.20

vertical orientation. Useful for sheet metal panels, printed circuit boards, and                           [ 6.9 ]               [ 15.9 ]

many other mounting surfaces. Fasteners not included.                                             Oval Hole         0.27                 0.6         3 Round Hole
                                                                                                                               [ 01         .56.39 ]
Description                           --------------------- Part Numbers ---------------------                  - Mounting Wing Top                                      - Mounting Wing    Top

Minimum Quantity   ...                     1,000                       100        ...

Blue, Oval Hole         75LOKWNGBLU-BK                       75LOKWNGBLU                                                                                   [ 5.1 ]

Blue, Round Hole        75LOKWNGBLU-R-BK                     75LOKWNGBLU-R                                                                                 Ø  .20             [ 27.4     ]

                                                                                                  Left Side View                     Right Side View                               1.08

                                                                                                  - Both Versions                       - Both Versions

Surface Mount for Locking Housings

Use to secure Powerpole® 75 series housings with locking dovetails to a flat                               [ 2.8 ]     [ 15.7 ]

surface. Useful for sheet metal panels, printed circuit boards, and many other                             0.11        0.62

mounting surfaces. Fasteners not included.

Description             ----------------- Part Numbers ----------------                                                [ 7.9 ]                                [ 43.2 ]        [ 4.9 ]

                                                                                                                       0.31                                   1.70            0.19

Minimum Quantity   ...  1,000                                     100        ...                  [ 3.6 ]

Blue                    75LOKSMTBLU-BK            75LOKSMTBLU                                        0.14  Top View                                        Side View

Spacer

Use to separate housings under high power to minimize power capability derating

due to heat rise. They are recommended for squaring off a block of Powerpole® 75                                       [ 17.0 ]                                               [ 17.0     ]

housings to enable mounting accessories or retaining pins to be used.                  Combining                       0.67                                                        0.67

long and short spacers opposite each other in a mated block adds keying features,

or use two short spacers to avoid interference.

Description                           ------------- Part Numbers -------------                                           [ 33.3]                                            [ 47.6 ]

Minimum Quantity…       1000                                               100     ....                                  1.31                                               1.87

Red, Short              1399G23-BK                           1399G23                              Short                                              Long

Red, Long               1399G21-BK                           1399G21

               

All Data Subject To Change Without Notice                                                                              www.andersonpower.com                                                - 37 -
                            Guide Housings for Vertical Mini Powerclaw Contacts

                            Prevents polarity being reversed when a two pole PP75 block is mated to

                            vertical mini Powerclaw contacts.      Fastening hardware not included.

                                           

                            Description                               ----------- Part Numbers ------------

                            Minimum Quantity     ...    1,000                            100        ...                                                                 PP75 Connector

                            Black Guide Housing         PC-HSG-PP-BK             PC-HSG-PP                                                                              Mini Vertical

                                                                                                                                                                                      Powerclaw Contact

                                                                                                                                                                        Guide Housing

                                                                                                                                                                                       PCB

                            Mounting Clamp

                            Mounting clamps can be used for fastening a block of Powerpole® 75 series

                            housings to a panel. Connector blocks must be a complete square for the

                            clamps to work properly. Fastening hardware not included.

                            Description               - Part Numbers -

                            Minimum Quantity  ...       50 sets of 2   ...

           Powerpole® PP75  2 or 4 Pole                   1463G1                                                                      Mounting Clamp

                            3 or 6 Pole                   1463G2

SECTION 2                                                                                                                                     Panel

                                                                                                                                                                                                        2  Pole          3 Pole

                            Retaining Pins

                            Retaining pins are used to keep stacked Powerpole® 75 series housings from separating.

                            Retaining pins are inserted in the circular opening between two housings stacked side by side.

                            Dimension B is +/- 0.015 in or 0.38 mm.

                                                                                                                                              Dimensions

                                                                                                                          - A -                                         -B-

                            Description               ------ Part Numbers ------                    inches               mm           inches  mm

                            Minimum Quantity     ...    1,000               100   ................................................................................

                            1 Block High                111812P7   110G19                           0.196 / 0.207        4.98 / 5.26  0.560   14.220

                            2 Block High                111812P6   110G18                           0.196 / 0.207        4.98 / 5.26  1.000   25.400

                                                                                                                                                                                                                 B

                            PCB Mounting Staples                                                                                                                                                                                 A

                            Reduce strain on solder joints during mating and unmating. Staples bend over the underside

                            of the PCB board to lock the housings in place. Staples are an interference fit with housings.

                                                        Number of                                                                           Staple

                                                        Stacked Powerpoles®                                                       Housings

                            ---- Part  Numbers ----     HxW

                            Minimum Quantity     .....             100           ......                                               PCB

                            PCSTAPLE-2                              1 x 2                                                                                                                                  Fasten the staple by

                                                                                                                                                                                                           bending the leads on the

                                                                                                                                            Slide staple over housings and                                 bottom of the board.

                                                                                                                                            into the holes in the board.

                            Reducing Bushings

                            Use with contact part number 5900-BK or 1307-BK to allow a smaller wire to

                            be used with the connector. Electrical capability is derated with smaller wire.

                                                                                                                                                                                                       Dimensions

                                                                                                                                                   - ID -                     - Length -

                            Contact Barrel Size         Wire Size                ------------------ Part Numbers ------------               inches                  mm  Inches         mm

                            Minimum Quantity  ....................................................    3,000                1,000      100   ........................................................                ID

                            #6 AWG [13.3 mm²]           #8 AWG [8.4 mm²]                                  -              5912-BK      5912  0.18    4.57                0.45    11.43                      Length

                            #6 AWG [13.3 mm²]           #12- 10 AWG [3.3- 5.3 mm²]                  5910-BK                    -      5910  0.14    3.56                0.47    11.94

                            #6 AWG [13.3 mm²]           #16- 14 AWG [1.3- 2.1 mm²]                  5913-BK                    -      5913  0.09    2.29                0.47    11.94

                                                                                                                                                                                                                    Wire Entrance

                            For environmentally sealed connector shells to hold Powerpole®

                            15-180 connectors, see SPEC Pak® product series on our

                            website, www.andersonpower.com

- 38 -                                     www.andersonpower.com                                                                                                                                           All Data Subject To Change Without  Notice
Powerpole® Connectors

- PP120: up to 240 Amps

                                                                                   PP120 series Powerpole® housings are designed to

                                                                                   accommodate up to 1/0 (50 mm²) wires and handle

                                                                                   high   currents                            up  to    240  amps.     Reducing        bushings

                                                                                   allow PP120 to accept down to #8 (10 mm²) wires.

                                                                                   Multiple     colors                        of  stackable  housings            combine   with

                                                                                   low resistance flat wiping technology to offer powerful

                                                                                   connection capability.

                                                                                   • Large Wire Range Accommodates up to 1/0 (50mm²) Wire

                                                                                   Reducing bushings allow as small as #8 (10 mm²) wire to be used                                   Powerpole® PP120  SECTION 2

                                                                                   • Low Resistance Silver Plated Copper Contacts

                                                                                   Allows currents up to 240 amps

                                                                                   • UL Rated for Hot Plugging up to 60 Amps

                                                                                   Great for battery or other applications where the ability to

                                                                                   interrupt circuits is required

| PP120 ORDERING INFORMATION                                            |

PP120 Housings               

The second to largest Powerpole® housing can be used with

wire contacts for up to 1/0 AWG [50mm²] or busbar contacts.

Description            -------- Part Numbers --------                                                         [ 22.2 ]

Minimum Quantity  ...       500            50         .......                                   0.88                                         [ 69.9 ]

Red                    1321G3-BK           1321G3                                                                                            2.75

Green                  1321G4-BK           1321G4                                                                             [ 22.2 ]                                     [ 23.7 ]

Black                  1321G1-BK           1321G1                                                                             0.88                                         0.93

White                  1321G2-BK           1321G2                                                                                                  [ 117.5 ]

Blue                   1321-BK             1321                                                                                                        4.63

Gray                   1321G8-BK           1321G8

PP120 Silver Plated Wire Contacts

Silver plated contacts offer superior electrical performance and durability up to 10,000 mating cycles.

New contacts for #1 to 1/0 AWG (35 to 50 mm²) offer extended capability in the same housings.  See

reducing bushings in accessory section for smaller wires.

                           Mating                                                                                       -A-         -B-

AWG    mm²   Force          -------- Loose Piece Part Numbers --------  inches    mm     inches    mm

Minimum Quantity  ........  600            500                 50       ....................................................

1/0    53.5  Low            1323G2-BK              -           1323G2   0.52       13.21  0.44  11.18

1      42.4  Low            1323G1-BK              -           1323G1   0.47       11.94  0.39  9.91

2      33.6  High                   -      1319-BK             1319     0.44       11.18  0.34  8.64                              [ 21.3 ]             [ 50.8 ]

4      21.1  High                   -      1319G4-BK           1319G4   0.44       11.18  0.29  7.37                                0.84               2.0

6      13.3  High                   -      1319G6-BK           1319G6   0.44       11.18  0.22  5.59                                    B

                                                                                                                                        A

                                                                                                                                                                 [ 10.4 ]

                                                                                                                                                                 0.41

All Data Subject To Change Without Notice                                                                                                    www.andersonpower.com                   - 39 -
                                | PP120 SPECIFICATIONS |

                                Electrical                                                                         Mechanical               

                                Current Rating Amperes ¹                       UL 1977        CSA    Wire Size Range                              AWG          mm²

                                  Singlepole UL 1977 (1/0 AWG)                 240            155      Wire Contacts with Bushings                10 to 1/0    5.3 to 53.5

                                  2x2 Block UL 1977 (1/0 AWG)                  200            110                   

                                                 Max. Wire Insulation Diameter                                                                                  in.          mm

                                Voltage Rating AC/DC                                                                                              0.600        15.240

                                  UL 1977                                      600                                  

                                                 Operating Temperature ²                                                                                        °F           °C

                                Dielectric Withstanding Voltage                                                                                   -4° to 221°  -20° to 105°

                                  Volts AC                                     2,200                                

                                                 Mating Cycles No Load by Plating                                                                               Silver (Ag)

                                Avg. Mated Contact Resistance Milliohms ¹                                 Wire Contacts                           10,000

                                  5 1/2” of #2 AWG wire                        0.136                                

                                                 Avg. Mating / Unmating Force                                                                                   Lbf.         N

                                UL Hot Plug Current Rating Amperes 4                                                                              8            36

                                  250 cycles at 120V DC                        60A                                       

           Powerpole® PP120                                                                               Min. Contact / Spring Retention Force Lbf.           N

                                Materials                                                                                                         60           267

SECTION 2                       Housing

                                Plastic Resin                         Polycarbonate

                                Contact Retention Spring              Stainless Steel

                                                                                                     NOTE 1: See IEC 60664-1 for working voltage.

                                Housing Flammability Rating                                          NOTE 2: Amp ratings are stated per position and based on all positions being fully loaded.

                                  UL94                                V-0                            ¹ Based on: 105°C rated or better cable of the largest size, Properly calibrated APP

                                  Glow Wire                           960°C (GWFI) / 850°C (GWIT)      recommended tooling, and a 25°C ambient temperature. UL rating not to exceed the

                                                                                                       maximum operating temperature. CSA rating below a 30°C temperature rise.

                                Contact                                                              ² Limited by the thermal properties of the connector plastic housing.

                                Base                                  Copper Alloy                   ³ Use APP recommended tooling only. Alternate tools may adversely affect the performance

                                Plating                               Silver                           of our connectors along with UL and CSA recognition.

                                                                                                     4 Based on 2 housings blocked together.

                                Contact Termination Methods

                                Crimp ³                               Wire Contacts

                                Hand Solder                           Wire Contacts

                                | IEC INFORMATION |

                                Connector                                           Creepage /       Material
                                                                                    Clearance
                                Series         Configurations                       per IEC 60950-1
                                                                                                     Group

                                               Single Pole            Unmated        4.36 mm

                                PP120                                 Mated          4.36 mm         IIIa

                                               Stacked Powerpole®     Unmated        4.36 mm

                                                                      Mated          4.36 mm

                                Attributes                                    PP120                                          Protection

                                AMP Rating AC/DC                              120                                            Touch Safety with Wire Contacts

                                Voltage Rating AC/DC     (Steady State)       400 V AC/DC ( Operational)                       IEC 60529          IP10

                                Breaking Capacity -AMP Rating /Cycles         120 Amp /  10 Cycles

                                Voltage Rating   (Breaking Capacity)          220 VDC

                                FINGER Safety - Mated only                    IEC 60529 - IP20

                                Wire Size tested                              50 mm²

                                Contact Series Tested                         1323G2

                                Climatic Testing (Cold,Heat & MFG)            IEC 60512 Test  -11j, 11i & 11g,

                                Cycle Life                                    IEC 60512 Test 9a - 5000 Cycles

                                Mechanical Strength  Impact                   IEC 60512-5 @ 29.5 Inches - dropped  8  times

                                Temperature Range                             -20 °C to 105 °C

                                                                              -4 °F to 221 °F

                                NOTE 3:  Refer to the Constructional Data form for additional information on our website., www.andersonpower.com

-          40                -                 www.andersonpower.com                                                                                           All Data Subject To Change Without Notice
     |  PP120                                               TEMPERATURE                    CHARTS |    Temperature rise charts are based on a 25°C ambient temperature.

     For Temperature Rise Above 60°C, Consult the Extended Temperature Rise Charts in the Appropriate Product Section on the Website.

                                                                     PP120 Singlepole                                                                                                  PP120 Multipole

                                                            Temperature Rise at Constant Current                                                                              Temperature Rise at Constant Current

                                                   60                                                                                                                  60

                                                   50                                                                                              Above Ambient (°C)  50

        Temperature Rise       Above Ambient (°C)  40                                                                            Temperature Rise                      40

                                                   30                                                                                                                  30

                                                   20                                                                                                                  20

                                                   10                                                                                                                  10                                                               Powerpole® PP120  SECTION 2

                                                      0  0      50       100  150         200     250                                                                  0

                                                                                                                                                                           0      50       100  150         200     250

                                                                         Amperes Applied                                                                                                   Amperes Applied

                                                                1/0 AWG       1 AWG            2 AWG                                                                              1/0 AWG       1 AWG            2 AWG

                                                                4 AWG         6 AWG                                                                                               4 AWG         6 AWG

     Current - Temperature Derating per IEC 60512-5-2 Test 5B

                                                                PP120 Singlepole                                                                                                     PP120 Multipole

                                                         Derating vs. Ambient Temperature                                                                                  Derating vs. Ambient Temperature

                               125                                                                                               125

     Ambient Temperature (°C)  100                                                                     Ambient Temperature (°C)  100

                               75                                                                                                75

                               50                                                                                                50

                               25                  0        50  100      150  200         250     300                            25

                                                                                                                                                   0                          50  100      150  200         250  300

                                                                     Amperes Applied                                                                                                 Amperes Applied

                                                            1/0 AWG           1 AWG        2 AWG                                                                           1/0 AWG              1 AWG       2 AWG

                                                            4 AWG             6 AWG                                                                                           4 AWG             6 AWG

All  Data Subject To Change Without Notice                                                                                                                                                                       www.andersonpower.com  - 41 -
                             | POWERPOLE® PP120 ACCESSORIES |

                             Mounting Clamp

                             Mounting clamps can be used for fastening a block of Powerpole® 120 series housings to a

                             panel. Connector blocks must be a complete square for the clamps to work properly. Fastening

                             hardware not included.

                             Description               - Part Numbers -                                                       Mounting Clamp

                             Minimum Quantity  ...     20 sets of 2  ......

                             2 Pole                      1464G1

                             3 Pole                      1464G2                                                                             Panel

                                                                                                                                                                         2   Pole                 3 Pole

                             Retaining Pins

                             Retaining pins are used to keep stacked Powerpole® 120 series housings from

                             separating. Retaining pins are inserted in the circular opening between two

                             housings stacked side by side. Dimension B is +/-                      0.015 in or 0.38 mm.

           Powerpole® PP120                                                                                                       Dimensions

                                                                                                                  - A -                                           -B-

SECTION 2                    Description               ----- Part Numbers -----   inches                     mm                             inches       mm

                             Minimum Quantity     ...  1,000      100             .........................................................................

                             1 Block High              111812P7   110G19          0.196 / 0.207              4.98 / 5.26      0.560        14.220

                             2 Block High              111812P8   110G20          0.196 / 0.207              4.98 / 5.26      1.500        38.100

                                                                                                                                                                                     B

                                                                                                                                                                                       A

                             Reducing Bushings

                             Use with contact part number 1319-BK to allow a smaller wire to be used with the connector.  

                             Electrical capability is derated with smaller wire.

                                                                      Dimensions

                                                                                                                                                                               - ID -

                             Contact Barrel Size       Wire Size                                    --------- Part Numbers ---------  inches                 mm           [  21.4 ]

                             Minimum Quantity  ...................................................    2,000    1,000          100   ........................                 0.84

                             #2 AWG [33.6 mm²]         #4 AWG [21.2 mm²]                            5919-BK        -          5919    0.28                   7.11

                             #2 AWG [33.6 mm²]         #6 AWG [16 mm²]                                    -  5920-BK          5920    0.23                   5.84  ID                     [ 8.4 ]

                             #2 AWG [33.6 mm²]         #10 - 8 AWG [5.3 - 8.4 mm²]                  5921-BK                   5921    0.18                   4.57                         0.33

                             For environmentally sealed connector shells to hold Powerpole®

                             15-180 connectors, see SPEC Pak® product series on our

                             website, www.andersonpower.com

- 42 -                                     www.andersonpower.com                                                                                                             All Data  Subject To Change  Without  Notice
Powerpole®                           Connectors

- PP180: up                          to 350 Amps

                                                                                        PP180 are the largest of the Powerpole® series housings.

                                                                                        They are designed to accommodate up to 3/0 (70 mm²)

                                                                                        wires and handle high currents up to 350 amps. Busbar

                                                                                        contacts are also available for power inputs and takeoffs.

                                                                                        Color-coded housings minimize user confusion and the

                                                                                        potential of cross mating circuits.

                                                                                        Low Resistance Silver Plated Copper Contacts

                                                                                        • Allows currents up to 350 amps

                                                                                        UL Rated for Hot Plugging up to 75 Amps                                                                                                   Powerpole® PP180  SECTION 2

                                           Wire to Busbar                               • Great for battery or other applications where                                                                         the  ability  to

                                                                                        interrupt circuits is required

                                                                                        Busbar Contacts Work with Standard Housings

                                                                                        • Provides a hot swappable quick disconnect system for busbar

                                                                                        power distribution

| PP180 ORDERING INFORMATION |

PP180 Housings               

The largest Powerpole® housing can be used with wire

contacts for up to 3/0 AWG [85mm²] or busbar contacts.

Description        -------- Part Numbers --------

Minimum Quantity  ...      250                 50   .......                   [ 28.6 ]

Red                1381G3-BK               1381G3                               1.13                      [ 82.6 ]

Green              1381G4-BK               1381G4                                                         3.25

Black              1381G1-BK               1381G1                                       [ 28.6 ]                                                       [ 30.0 ]

White              1381G2-BK               1381G2                                             1.13                                                     1.18

Blue               1381-BK                 1381                                                                   [ 129.7 ]

                                                                                                                     5.5

                                                                              Front View                                  Mated Length

PP180 Silver Plated Wire Contacts

Silver plated contacts offer superior electrical performance and durability up to 10,000 mating cycles.  New contacts for 2/0 to 3/0 AWG

(70 to 85 mm²) offer extended capability in the same housings. See Reducing bushings in accessory section for smaller wires.

                                                                                                                                                 Dimensions

                           Mating                                                                                                       -A-               -B-                     -C-                      -D-

AWG    mm²   Force          ---------- Loose Piece Part Numbers -----------             inches  mm        inches  mm                    inches  mm     inches         mm

Minimum Quantity  ........      500               300              250      50         .......................................................................................................................

3/0    85    Low                  -                 -        1328G2-BK  1328G2          2.35    59.69     0.70    17.78                 0.58    14.73  1.04           26.42

2/0    67.4  Low                  -        1328G1-BK        -           1328G1          2.35    59.69     0.64    16.26                 0.49    12.45  1.04           26.42

1/0    53.5  High           1382-BK                 -                -  1382            2.35    59.69     0.52    13.21                 0.44    11.18  1.04           26.42

1      42.4  High           1347-BK                 -                -  1347            2.35    59.69     0.52    13.21                 0.39    9.91   1.04           26.42

2      33.6  High           1383-BK                 -                -  1383            2.35    59.69     0.52    13.21                 0.35    8.89   1.04           26.42

4      21.1  High           1384-BK                 -                -  1384            2.35    59.69     0.52    13.21                 0.30    7.62   1.04           26.42

6      13.3  High           1348-BK                 -                -  1348            2.10    53.34     0.37    9.40                  0.22    5.59   0.80           20.32

                                                                                                       D                  A

                                                                                                    C

                                                                                                       B                                                                                                        [  12.70  ]

                                                                                                                                                                                                                   050

All Data Subject To Change Without Notice                                                                                                     www.andersonpower.com                                                               - 43 -
                                PP180 Silver Plated Busbar Contacts

                                Use 2 busbar contacts per housing to provide a quick disconnect input or                         See Busbar contact drawing on

                                output busbar connection. Busbar contacts are for mating with wire contacts                      website for further detail.

                                only. Part number 180BBS includes lock nuts. Locknuts must be ordered                                                                                       [ N/A ]

                                separately for 180BBS-BK.                                                                                      [ 109.7 ]                                    1/4-20

                                                                                                                                               4.3             [ 2.7 ]                               [ 25.4  ]

                                                      Mating                                                                                                    0.50                                 1.0

                                Thread                Force      ------ Loose Piece Part Numbers ------

                                Minimum Quantity  ................        1,000       120     10         .....

                                Busbar 1/4-20         High       180BBS-BK        180BBS        -

                                Lock Nut 1/4-20       N/A        H1216P7          110G56   110G55

                                                                                                                                                                                   [ 4.6 ]

                                                                                                                                                                                   0.18

                                | PP180 SPECIFICATIONS |

                                Electrical                                                                                    Mechanical               

                                Current Rating Amperes ¹                          UL 1977  CSA                  Wire Size Range                           AWG           mm²

           Powerpole® PP180       Singlepole (wire-wire) (3/0 AWG)                350      230                    Wire Contacts with Bushings             10 to 3/0     5.3 to 85

                                  2x2 Block (wire-wire) (3/0 AWG)                 350                                          

SECTION 2                       Singlepole (wire-busbar) (1/0 AWG)                180                           Max. Wire Insulation Diameter             in.           mm

                                                                                                                                                          0.900         22.860

                                Voltage Rating AC/DC                                                                           

                                  UL 1977                                         600                           Operating Temperature ²                   °F            °C

                                                                                                                                                                        -4° to 221°   -20° to 105°

                                Dielectric Withstanding Voltage                                                                

                                  Volts AC                                        2,200                         Mating Cycles No Load by Plating          Silver (Ag)

                                                 Wire and Busbar Contacts                                                                                               10,000

                                Avg. Mated Contact Resistance Milliohms ¹                                                      

                                  6” of 1/0 AWG wire                              0.100                         Avg. Mating / Unmating Force              Lbf.          N

                                                 Wire & Busbar Contacts                                                                                                 10            44

                                UL Hot Plug Current Rating Amperes 4                                                           

                                  250 cycles at 120V DC                           75A                           Min. Contact / Spring Retention Force     Lbf.          N

                                                                                                                                                          120           534

                                Materials

                                Housing

                                Plastic Resin                       Polycarbonate

                                Contact Retention Spring            Stainless Steel

                                Housing Flammability Rating

                                  UL94                              V-0

                                  Glow Wire                         960°C (GWFI) / 850°C (GWIT)

                                Contact

                                Base                                Copper Alloy

                                Plating                             Silver

                                Contact Termination Methods

                                Crimp ³

                                Hand Solder

                                Wrench / Socket*

                                *Busbar Contacts Only

                                NOTE 1: See IEC 60664-1 for working voltage.

                                NOTE 2: Amp ratings are stated per position and based on all positions being fully loaded.

                                ¹ Based on: 105°C rated or better cable of the largest size, Properly calibrated APP recommended tooling, and a 25°C ambient temperature. UL rating not to

                                  exceed the maximum operating temperature. CSA rating below a 30°C temperature rise.

                                ² Limited by the thermal properties of the connector plastic housing.

                                ³ Use APP recommended tooling only. Alternate tools may adversely affect the performance of our connectors along with UL and CSA recognition.

                                4 Based on 2 housings blocked together.

-          44                -                   www.andersonpower.com                                                                                                  All Data Subject To Change Without Notice
| IEC INFORMATION |

     Connector                                                                                      Creepage /       Material
                                                                                                    Clearance
     Series                                                                                         per IEC 60950-1  Group
                                                              Configurations

                                                              Single Pole              Unmated      6.02 mm

     PP180                                                                             Mated        6.02 mm               IIIa

                                                              Stacked Powerpole®       Unmated      6.02 mm

                                                                                       Mated        6.02 mm

     Attributes                                                                               PP180                                                                         Protection

     AMP Rating AC/DC                                                                         180                                                                           Touch Safety with Wire Contacts

     Voltage Rating AC/DC                                               (Steady State)        500 V AC/DC ( Operational)                                                      IEC 60529          IP10

     Breaking Capacity -AMP Rating /Cycles                                                    180 Amp /  10 Cycles

     Voltage Rating   (Breaking Capacity)                                                     220 VDC

     FINGER Safety - Mated only                                                               IEC 60529 - IP20                                                                                                                                         Powerpole® PP180  SECTION 2

     Wire Size tested                                                                         70 mm²

     Contact Series Tested                                                                    1382G2

     Climatic Testing (Cold,Heat & MFG)                                                       IEC 60512 Test  -11j, 11i & 11g,                                              NOTE 3:  Refer to the Constructional Data form for additional

     Cycle Life                                                                               IEC 60512 Test 9a - 5000 Cycles                                               information on our website., www.andersonpower.com

     Mechanical Strength  Impact                                                              IEC 60512-5 @ 29.5 Inches - dropped       8  times

     Temperature Range                                                                        -20 °C to 105 °C

                                                                                              -4 °F to 221 °F

| PP180 TEMPERATURE CHARTS |                                                                                         Temperature        rise charts are based on a 25°C ambient temperature.

     For                                           Temperature Rise Above 60°C, Consult the Extended         Temperature  Rise  Charts  in the Appropriate Product Section on the Website.

                                                                   PP180 Singlepole                                                                                                                             PP180 Multipole

                                                          Temperature Rise at Constant Current                                                                                                  60     Temperature Rise at Constant Current

                                                   60

                                                   50                                                                                                                                           50

     Temperature Rise          Above Ambient (°C)  40                                                                                             Temperature Rise          Above Ambient (°C)  40

                                                   30                                                                                                                                           30

                                                   20                                                                                                                                           20

                                                   10                                                                                                                                           10

                                                   0                                                                                                                                            0

                                                       0  50       100  150  200      250  300     350                                                                                              0  50       100  150  200    250  300       350

                                                                   Amperes Applied                                                                                                                              Amperes Applied

                                                          3/0 AWG            2/0 AWG       1/0 AWG                                                                                                     3/0 AWG       2/0 AWG          1/0 AWG

                                                          1 AWG              2 AWG          4 AWG                                                                                                      1 AWG              2 AWG            4 AWG

     Current                                           - Temperature Derating per IEC 60512-5-2 Test     5B

                                                                   PP180 Singlepole                                                                                                                             PP180 Multipole

                                                          Derating vs. Ambient Temperature                                                                                  125                        Derating vs. Ambient Temperature

                               125

     Ambient Temperature (°C)  100                                                                                                                Ambient Temperature (°C)  100

                               75                                                                                                                                           75

                               50                                                                                                                                           50

                               25                                                                                                                                           25

                                                   0      50  100       150  200  250  300    350   400                                                                                            0   50  100       150  200  250    300  350    400

                                                                        Amperes Applied                                                                                                                              Amperes Applied

                                                          3/0 AWG            2/0 AWG        1/0 AWG                                                                                                    3/0 AWG            2/0 AWG          1/0 AWG

                                                          1 AWG              2 AWG            4 AWG                                                                                                    1 AWG              2 AWG            4 AWG

All  Data Subject To Change Without Notice                                                                                                                                                                                www.andersonpower.com        - 45 -
                             |  POWERPOLE® PP180 ACCESSORIES                                                                  |

                                Mounting Clamp

                                Mounting clamps can be used for fastening a block of

                                Powerpole® 180 series housings to a panel. Connector                                                Mounting Clamp

                                blocks must be a complete square for the clamps to work

                                properly. Fastening hardware not included.

                                Description           - Part Numbers -                                                                    Panel

                                Minimum Quantity ...    20 sets of 2  .....                                                                                                                        2  Pole                   3 Pole

                                2 Pole                    1465G1

                                3 Pole                    1465G2

                                Retaining Pins

           Powerpole® PP180     Retaining pins are used to keep stacked Powerpole® 180 series housings from separating.

                                Retaining pins are inserted in the circular opening between two housings stacked side by side.

                                Dimension “B” is +/- .015 in or .38 mm.

SECTION 2                                                                                                                            Dimensions

                                                                                                                                -A-                 -B-

                                Description           ----- Part Numbers -----                             inches                     mm

                                Minimum Quantity ...  1,000                  100  ..................................................................................

                                1 Block High          111812P6    110G18          0.196 / 0.207                   4.98 / 5.26       1.000  25.400

                                2 Block High          111812P8    110G20          0.196 / 0.207                   4.98 / 5.26       1.500  38.100

                                                                               

                                                                                                                                                                                                      B

                                                                                                                                                                                                               A

                                Reducing Bushings               

                                Use with contact part number 1382-BK to allow a smaller wire to be used with the connector. Electrical

                                capability is derated with smaller wire.                               

                                                                                                                                                                                                                Dimensions

                                                                                                                                                                                                                      - ID -

                                Contact Barrel Size   Wire Size                                         ----------------- Part Numbers ----------------               inches  mm

                                Minimum Quantity .....................................................     1,500       1,000     500       100           ............................

                                1/0 AWG [53.5 mm²]    #1 AWG [42.4 mm²]                                 -              -         5687-BK   5687                       0.39    9.91     [  25.4  ]

                                1/0 AWG [53.5 mm²]    #2 AWG [33.6 mm²]                                 5690-BK        -         -         5690                       0.34    8.64                       ID

                                1/0 AWG [53.5 mm²]    #4 AWG [21.2 mm²]                                 -              5693-BK   -         5693                       0.27    6.86        1.0

                                1/0 AWG [53.5 mm²]    #6 AWG [13.3 mm²]                                 -              5663-BK   -         5663                       0.22    5.59

                                1/0 AWG [53.5 mm²]    #10 - 8 AWG [5.3 - 8.4 mm²]                       5648-BK        -         -         5648                       0.19    4.83

                                                                                                                                                                                                         Wire  Entrance

                                For environmentally sealed connector shells to hold Powerpole®

                                15-180 connectors, see SPEC Pak® product series on our

                                website, www.andersonpower.com

-          46                -                www.andersonpower.com                                                                                                                                   All Data Subject To Change     Without  Notice
Powerpole®

- Tooling Information

Wire Size             Reeled Part Numbers                 Reeled Contact Crimp Tool

                      Tin                  Silver              APP

AWG       mm²         Plating              Plating      Applicator               APP Press

          PP15 / 45 Flat Wiping Power & Ground

#16 / 20  1.3 / 0.52  262G1                262G2

#16 / 20  1.3 / 0.52  269G2                N/A

#12 / 16  3.3 / 1.3   261G1                N/A                 TD0101

#10 / 14  5.3 / 2.1   261G2                261G3                            115V= TE0101

#12 / 16  3.3 / 1.3   269G1                N/A                              230V = TE0102

#10 / 14  5.3 / 2.1   269G3                N/A                                                                                          Powerpole® Tooling  SECTION 2

#10 / 14  5.3 / 2.1   200G1L               200G3L

#10 / 14  5.3 / 2.1   201G1H               N/A                 TD0102

#10 / 14  5.3 / 2.1   1830G1               1830G2

NOTE: Insertion / Extraction tool for PP15/45 contacts = 111038G2

* APP applicators are mechanical feed style and do not require an air feed kit.

Wire      Size        Loose Piece Part Numbers             Loose Piece Contact Crimp                  Tool

                                                                    Pneumatic

                      Tin                  Silver       Hand        Bench                             Number

AWG       mm²         Plating              Plating      Tool    or  Tool       +  Die     +  Locator  of Crimps

                           PP15 / 45 Flat Wiping Power & Ground

#16 / 20  1.3 / 0.52  N/A                  1332

#12 / 16  3.3 / 1.3   N/A                  1331        1309G2

                                                           or

#16 / 20  1.3 / 0.52  262G1-LPBK           262G2-LPBK   1309G8

#16 / 20  1.3 / 0.52  269G2-LPBK           N/A

#12 / 16  3.3 / 1.3   261G1-LPBK           N/A

#10 / 14  5.3 / 2.1   261G2-LPBK           261G3-LPBK   1309G3         N/A        N/A        N/A      Single

                                                           or

#12 / 16  3.3 / 1.3   269G1-LPBK           N/A          1309G8

#10 / 14  5.3 / 2.1   269G3-LPBK           N/A

#10 / 14  5.3 / 2.1   200G1L-LPBK  200G3L-LPBK          1309G6

#10 / 14  5.3 / 2.1   201G1H-LPBK          N/A             or

                                                       1309G8

310 / 14  5.3 / 2.1   1830G1-LPBK  1830G2-LPBK

                                                    PP75

#6        13.3                             1307                                              1389G6

                                           5900

#8        8.4                              1875G1                                1388G6      1389G21

                                           5952                                              1389G6

                      N/A                  1875G2       1309G4      1387G1                   1389G21  Single

#10 / 12  5.3 / 3.3                        5953

                                           5915                                  1388G7      1389G6

                                           1875G3                                            1389G21

                                                    PP120

1/0       53.5                             1323G2                                1388G3

#1        42.4                             1323G1

#2        33.6        N/A                  1319         1368        1387G1                   1389G4   Single

#4        21.2                             1319G4       Series                   1388G4

#6        13.3                             1319G6

                                                    PP180

3/0       85                               1328G2                                1303G12

2/0       53.5                             1328G1

1/0       53.5                             1382

#1        42.4        N/A                  1347         1368        1387G2       1303G13     1304G32  Double

#2        33.6                             1383         Series

#4        21.1                             1384

#6        13.3                             1348                     1387G1       1388G4      1389G3   Single

1. NOTE: See website for the most current information.

2. NOTE: Insertion / Extraction fool for PP15/45 contacts = 111038G2

All Data Subject To Change Without Notice                                                                        www.andersonpower.com  - 47 -
                             Overview of SBS®, SB® & SBX® / SBO®

                             - Main Differentiating Features

                                                                                                      SBS®: The “Storage Battery Safety” connector provides a

                                                                                                      compact connection with a touch safe interface. The newest

                                                                                                      series of the Multipole connector family continues to add new

                                                                                                      features and capabilities.

                                                                                                      SB®: Based on the original “Storage Battery” connector that

                                                                                                      pioneered flat wiping contact technology over a half century

                                                                                                      ago. Two to three positions in a genderless mechanically-keyed

                                                                                                      housing are suitable for a wide array of power connection

                                                                                                      applications.

                                                                                                      SBX®: The addition of auxiliary positions to the SB® cre-

                                                                                                      ated the “Storage Battery Auxiliary” connector. Up to 8 aux-

                                                                                                      iliary positions allow expanded capabilities for the Multipole

                                                                                                      family by allowing intelligent power switching, monitoring of

                                                                                                      battery charge status, and other signal functions to be inte-

                                                                                                      grated into a single connector.

                                                                                                      SBE®: By modifying the SBX® housing the “Storage Battery

                                                                                                      European” connector was created. The SBE® housings are

                                                                                                      molded from a chemical resistant PBT resin and the SBE®320

           Multipole Family                                                                           features improved touch safety over the SBX®350 design.

SECTION 3                                                                                             SBO®:     Designed      to  meet  the  needs       of  connecting     office

                                                                                                      equipment, the “Storage Battery Office” connector is molded

                                                                                                      out of durable PC like the original SB® but incorporates the

                                                                                                      auxiliary positions of the SBX® in a housing similar to the

                                                                                                      SBE®80.

                                                                                                      SB® Smart: Designed for applications where storage batter-

                                                                                                      ies intelligently interact with the system. Two primary power

                                                                                                      positions are combined with sixteen auxiliary power / signal

                                                                                                      positions.   This allows one connection to be used to route

                                                                                                      high power lines, low power lines, and signal circuits.

                             Hot Plugging AC or DC

                             Contacts feature a sacrificial tip that

                             allow high current circuit interrupt           Genderless Housings

                                                                            Provide  simplified  assembly  and

                                                                            minimize the number of components

                                                                                                                       Keyed & Color Coded Housings

                                                                                                                       Prevents accidental cross mating

                                                                                                                       of circuits

           Low Resistance Connection                                                                                                         Compact Power to Size Ratio

           Silver or tin plated contacts                                                                                                     Maximizes       valuable  PCB  edge

           inside            housings  that  strongly                                                                                        real estate with a compact high

           force the contacts together                                                                                                       power design

                                       Self Securing Design

                                       Stainless    steel          springs  create   a

                                       robust force between the contacts

                                       that  holds  the            connector  in     the

                                       mated condition                                           Auxiliary or Ground Positions

                                                                                                 For  signal    transmission  or  the

                                                                                                 added     safety  of  a      premate

                                                                                                 ground

-          48 -              www.andersonpower.com                                                                                           All Data Subject To Change Without Notice
|  MULTIPOLE FAMILY SELECTION GUIDE                                          |

                                           SBS® Mini  SBS®        SB®        SBX®  /  SBE® /    SBO®  SB® Smart

   Page Number                             53         57          67                  87              105

   Amps Per Pole                           52         50 - 110    50 - 500            60 - 350        230

   Volts (UL) Per Pole                     600        600         600                 600             600

   Wire Gauge (AWG)                        10 - 20    16 - 6      16 - 350            6 - 300         10 to 1/0

   Wire Gauge (mm²)                        4 - 0.75   1.3 - 13.3  1.3 - 150           24 - 152        5.3 to 53.5

   Number of Power Circuits                2          2-3         2-3                 2               2

   Number of Auxiliary Circuits            0          4           0                   8               16

   PCB Mount                                          ●           ●                                   ●

   Bus Bar                                                        ●                                   ●

   Panel Mount                                        ●           ●

   Hot Plug                                ●          ●           ●                   ●               ●

   Touch Safe                              ●          ●                               ●

   Mechanically Keyed                      ●          ●           ●                   ●               ●

   Handle                                             ●           ●                   ●

   Air Supply System                                                                  ●

   Environmental Protection                                       ●

Actual Size - Connector Half                                                                                                            Multipole Family  SECTION 3

                  SB®50                                              SB®120                                        SB®175 - 2 Pole

           Protect your SB® 50, 120 & 175 connectors from                    water, dirt, chemicals

           and UV light with the SB® Environmental Boot. It protects                  the SB®

           connectors in both the mated and unmated condition. More information

           in the SB® accessory section.

All Data Subject To Change Without Notice                                                                        www.andersonpower.com  - 49 -
                                Actual  Size  - Connector Half

SECTION 3  Multipole Family                   SB®175 - 3 Pole                    SB®350

                                              SBE®60 - SBO®80        SBE®160  -  SBX®175

-          50                -                www.andersonpower.com                       All  Data  Subject  To  Change  Without  Notice
                                                                                                SBS®50             SBS® Mini

                                                                                                                               Multipole Family  SECTION 3

                                           SBE®320 - SBX®350                                    SBS®75X & SBS®75G

Explanation of Mechanical Voltage Keys

Features molded into the mating interface of the connector housing

prevent  accidental                        cross  mating  of  circuits.  This  molded  feature

mechanically keys the connection so that only housings with the same

mating interface can be mated together.

Different mechanical keys can be easily recognized by the color of

the housing. This color coding corresponds to a voltage that industrial

trucks, batteries, and chargers have adopted as a standard to prevent

incompatible voltages from cross mating.

The same mechanical keying and color coding that is so successful for

industrial trucks, is also widely used in power electronics applications.

UPS systems, power supplies, personal mobility, and alternative

energy applications have all used this feature to ensure user safety.

Note: Some housings in the SB®50, SB®175, and SB®350 series have

different colored housings with a shared mechanical keying feature.

Please see the specific data sheet for details.

Recommended Voltage Key Color Code

Voltage   12V         18V           24V     36V      48V      72V        80V       96V        120V       144V

Color       Yellow     Orange     Red     Gray     Blue     Green     Black     Brown     Purple     White

All Data Subject To Change Without Notice                                                               www.andersonpower.com  - 51 -
                                                    | NOTES |

SECTION 3  Multipole Family

           - 52 -            www.andersonpower.com             All Data Subject To Change Without Notice
SBS® Mini Connectors

- up to 52 amps

                                                                  SBS®      Mini   Connector            series       is  our        smallest      DC

                                                                  power connector in the SB® group. The SBS® Mini

                                                                  securely holds two crimp and poke contacts with

                                                                  sacrificial tips to enable hot swap capabilities on DC

                                                                  circuits. The low resistance contacts accept 20 to

                                                                  10 AWG (0.75 to 4.0 mm²) wires allowing up to 52

                                                                  amps of UL rated performance per position.  

                                                                  •  Touch Safe Housing

                                                                     Minimizes potential contact with live circuits

                                                                  •  Color-Coded Mechanical Key

                                                                     Prevents accidental mating of connectors operating at

                                                                     different voltage levels

                                                                  •  Compact & Ergonomic Housing

                                                                     Is “user friendly”       during connection and disconnection

                                                                     of the system

                                                                  •  UL Hot Plug Rated to 45 Amps @ 72 Volts

                                                                     Good for applications where the ability to interrupt                             SBS® Mini  SECTION 3

                                                                     circuits is required

| SBS® MINI ORDERING INFORMATION                               |

SBS® Mini Housing                                                 Actual Size

The smallest SBS® connector has 2 finger proof positions in                                [  10.7   ]  [ 10.1 ]

a polycarbonate housing with an ergonomic grip. The housing                                   0.42      0.40

securely holds crimp and poke contacts from the popular           Top View                                                          [ 2.4 ]

Powerpole® 15-45 series connectors.                                                                                              Ø  0.09     (2)

Description                         - Part Numbers -                                         [ 22.0 ]

                                                                                  0.87

Minimum Quantity ...         100

Red                      B02265G1

Gray                     B02265G4

Blue                     B02265G3

Black                    B02265G2

                                                                  Side View                                                   [  11.7  ]

                                                                                  [ 8.5 ]                                        0.46

                                                                                  0.33

                                                                                              [7.9]

                                                                                              0.31      [  28.7      ]

      Blue            Black                Red           Gray                                              1.13

                                                                  Mated Side View                                 [  49.4  ]

                                                                                                                     1.95

All Data Subject To Change Without Notice                                                               www.andersonpower.com                         - 53 -
                      PP15-45 Tin Plated Power Contacts

                      Offer cost effective performance up to 200 mating cycles.  See specifications and temperature

                      charts for amperage ratings by wire size.

                                                                                                                                   Dimensions               

                                                                                        Loose Piece        Reeled              - A -

                      Barrel   AWG               mm²               -------- Part Numbers -------       inches         mm

                      Minimum Quantity  ........................            200              5,000         .........................

                      Open     14 to 10 K*       2.1 to 5.3        261G2-LPBK             261G2        0.20           5.08                                           [ 17.27 ]                                       [ 6.35 ]

                      Open     16 to 12          1.3 to 3.3        261G1-LPBK             261G1        0.18           4.57                                            0.68                                           0.25

                      Open     20 to 16          0.52 to 1.3       262G1-LPBK             262G1        0.16           4.06

                      K*  - For #10 AWG class K stranded wire or smaller.                                                                                               [ 3.81 ]                       A

                                                                                                                                                                            0.15

                      PP15-45 Silver Plated Power Contacts

                      Maximize performance by offering up to 1,500 mating cycles.                Recommended for circuit interrupt or

                      hot plug applications.  See specifications and temperature charts for amperage ratings by wire size.  Only closed

                      barrel contacts are suitable for soldering.

                                                                                                                                                                                        Dimensions

                                                                           Loose Piece                       Reeled                         - A -                                   -B-

                      Barrel   AWG                    mm²          ----- Part Numbers ------           - Part Numbers -               inches      mm            inches      mm

                      Minimum Quantity ...........................    5,000              200                   5,000               ............................................................

                      Open     14 to 10 K*            2.1 to 5.3         -       261G3-LPBK                   261G3                   0.20        5.08            -           -

                      Open     20 to 16               0.52 to 1.3        -       262G2-LPBK                   262G2                   0.16        4.06            -           -

                      Closed   16 to 12               1.3 to 3.3   1331-BK             1331                        -                  0.15        3.81          0.10        2.54

                      Closed   20 to 16               0.52 to 1.3  1332-BK             1332                        -                  0.12        3.05          0.07        1.78

                      K*  - For #10 AWG class K stranded wire or smaller.

                      Open Barrel Contact                                                                                             Closed Barrel Contact

                               [ 17.27 ]                           [ 6.35 ]                                                           [ 16.26 ]                                   [ 7.35               ]

                                 0.68                                    0.25                                                         0.64                                                       0.29

SECTION 3  SBS® Mini                [ 3.81 ]                                                                                                  [ 3.81 ]       B

                                           0.15       A                                                                                           0.15          A

                      SBS® Mini

                      - Tooling Information

                      Wire Size            Loose Piece Part Numbers                       Reeled Part  Numbers                                          Reeled Contact Crimp Tools

                                                 Tin              Silver         Hand         Tin            Silver                   APP                    APP                 ATS                      ATS        Air Feed

                      AWG      mm²          Plating               Plating        Tool or      Plating        Plating                  Applicator             Press          Applicator                    Press      Kit*

                      16 / 20  1.3 / 0.52        N/A               1332          1309G2       N/A                N/A                  N/A                    N/A                 N/A                      N/A        N/A

                      12 / 16  3.3 / 1.3         N/A               1331          or

                      16 / 20  1.3 / 0.52  262G1-LPBK      262G2-LPBK            1309G8       262G1          262G2                                                          1385519-1

                      12 / 16  3.3 / 1.3   261G1-LPBK              N/A           1309G3       261G1              N/A                                 115V = TE0101          1385520-1                     1725900-2  1424266-1

                                                                                 or                                                   TD0101         230V = TE0102

                      10 / 14  5.3 / 2.1   261G2-LPBK      261G3-LPBK            1309G8       261G2          261G3                                                          1385458-1

                                                                                          Need More Than 2 Positions?

                                                                                          See the stackable Powerpole® 15 to 45 connectors. These single                                                                        position

                                                                                          connectors use the same contact system as SBS® Mini and can be                                                                        stacked

                                                                                          together to create custom multiple position configurations.

           - 54 -                   www.andersonpower.com                                                                                                                                              All Data Subject To Change Without Notice
| SBS® MINI SPECIFICATIONS |

Electrical                                                                                 Mechanical               

Current Rating Amperes ¹                                  UL 1977  CSA       Wire Size Range                               AWG          mm²

   10 AWG                                                 52       35                                                      20 to 10     0.75 to 4.0

   12 AWG                                                 41       28                       

   14 AWG                                                 31       23        Max. Wire Insulation Diameter                 in.          mm

   16 AWG                                                 24       16                                                      0.183        4.65

   18 AWG                                                 20       15                       

                 Operating Temperature                                                                                                   ˚F           ˚C

Voltage Rating AC/DC                                                                                                       -4˚ to 221˚  -20˚ to 105˚

   UL 1977                                                600                               

                 Mating Cycles No Load by Plating                                                                                        Silver (Ag)  Tin (Sn)

Dielectric Withstanding Voltage                                                 10 - 12 AWG                                1,500        200

   Volts AC                                               2,200                 14 - 18 AWG                                8,000        200

                                

Avg. Mated Contact Resistance Milliohms 2                                    Avg. Mating / Unmating Force 4                Lbf.         N

   Wire Contact with 5/8” of #16 AWG                      0.875                 10 AWG                                     10 to 11     45 to 49

   Wire Contact with 5/8” of #12 AWG                      0.600                 12 to 18 AWG                               4 to 7       17 to 31

   Wire Contact with 5/8” of #10 AWG                      0.525                             

                 Min Contact / Spring Retention Force                                                                                    Lbf.         N

UL Hot Plug Current Rating Amperes 3                                                                                       20           90

   250 cycles at 72V DC                                   45A

Materials               

Housing               
                                                                             NOTE 1: See IEC 60664-1 for working voltage.
Plastic Resin                              Polycarbonate
                                                                             ¹ Based on: 105°C rated or better cable of the largest size, Properly calibrated APP
Contact Retention Spring                   Stainless Steel
                                                                               recommended tooling, and a 25°C ambient temperature. UL rating not to exceed the
               
                                                                               maximum operating temperature. CSA rating below a 30°C temperature rise.
Housing Flammability Rating
                                                                             2 Use APP recommended tooling only. Alternate tools may adversely affect the
   UL94                                    V-0
                                                                                performance of our connectors along with UL and CSA recognition.
   Glow Wire                               960°C (GWFI) / 800°C (GWIT)
                                                                             3 Based on 261G3 with 10 AWG wire.
                                                                                                                                                                                 SBS® Mini  SECTION 3
                                                                             4 Contact customer service for contacts with a higher disconnect force.
Contact               

Base                                       Copper Alloy

Plating                                    Tin or Silver

               

Contact Termination Methods               

Crimp ³                                    Wire Contacts                                                                        Inquire with Customer Service

   Hand Solder                             1331 & 1332                                                                          for IEC / EN Approvals

| IEC INFORMATION |

Connector                                  Creepage/Clearance      Material

Series          Configurations             per IEC 60950-1         Group

                Unmated                    1.47 mm

SBS®Mini                                                           IIIa

                Mated                      2.40 mm

Protection

Touch Safety

  UL 1977 Sec. 10.2       Pass

  IEC 60950               Pass

  IEC 60529               IP20

NOTE 2:  Refer to the Constructional Data form for additional information    on  our  website.,  www.andersonpower.com

All Data Subject To Change Without Notice                                                                                       www.andersonpower.com              - 55 -
                      |  TEMPERATURE                                                  CHARTS                 |   Temperature rise charts are based on a 25°C ambient temperature.

                      For Temperature Rise Above 60°C, Consult the Extended Temperature Rise Charts in the Appropriate Product Section on the Website.

                      Current - Temperature Derating per IEC 60512-5-2 Test 5B

                                                                                  SBS® Mini                                                                    SBS® Mini

                                                                      Temperature Rise at Constant  Current                                        Derating vs. Ambient Temperature

                                                               60                                                                          125

                                           Above Ambient (°C)  50                                                Ambient Temperature (°C)

                         Temperature Rise                                                                                                  100

                                                               40

                                                               30                                                                          75

                                                               20

                                                                                                                                           50

                                                               10

                                                               0                                                                           25

                                                                   0  10      20  30         40     50       60                                 0  10      20  30  40       50  60   70

                                                                              Amperes Applied                                                              Amperes Maximum

                                                                      10 AWG      12 AWG            14 AWG                                         10 AWG      12 AWG           14 AWG

                                                                      16 AWG      18 AWG                                                           16 AWG      18 AWG

SECTION 3  SBS® Mini

           - 56 -                                                     www.andersonpower.com                                                                                             All Data Subject  To  Change  Without  Notice
SBS® Connectors

- up to 110 amps

                                                                           The  patented            SBS®   connector           family  is    designed   to

                                                                           provide high power in a compact ergonomic housing

                                                                           with protection against accidental contact with live circuits.

       SBS®75G                                                             This is of particular importance in applications where

                                                                           DC   voltages            exceed       30  volts     and     can       be   health

                                                                           threatening.

                                                          SBS®75X

                                                          Wire to Wire     Wire-to-wire             and  wire-to-board             configurations       both

                                                                           provide       power         contacts     rated      up  to  110       amps.  The

                                                                           SBS®75X             offers  up  to    4   mate-last     break-first        auxiliary

                                                                           power      /  signal        contacts      rated     up  to  20        amps.  The

                                                                           SBS®75G features a third first-mate last-break ground

                                                                           or power contact. All contact positions are rated for

                                                                           circuit interruption (hot plugging).

                                                                           • Touch Safe Interface

                                                                           - Can safely be used in through panel applications

                                                                           - Minimizes potential contact with live circuits per IEC 60950

                                                                           • Wire-to-Wire and Wire-to-Board Configurations

                                                                           Allows one connector to meet multiple needs

                                           SBS®50                          • Ground or Auxiliary Positions Integrated into the

                                                                           One Piece Housing

                                                                           Meets all connection requirements in one compact                                      SBS® 50 & 75  SECTION 3

                                                                           connector housing

| SBS® ORDERING INFORMATION                                             |

SBS®50 Standard Housings                       

Polycarbonate housings feature 2 positions all finger proof.

Genderless design mates with itself. Mechanical keys are

color coded.

Description                             ----------- Part Numbers -----------                                                       [ 19.1 ]

Minimum Quantity  ......  500                      50           ...                   [ 3.6 ]                        0.75              [ 6.3 ]

Red                                     SBS50RED-BK      SBS50RED                                 0.14 (2)                                           0.25

Gray                                    SBS50GRA-BK      SBS50GRA

Blue                      SBS50BLU-BK      SBS50BLU

Black                     SBS50BLK-BK      SBS50BLK

Brown                                   SBS50BRN-BK      SBS50BRN                                                                                    [ 36.1 ]

White                                   SBS50WHT-BK      SBS50WHT                                                                                    1.42

                                                                           [  18.0 ]

                                                                              0.71

SBS®50 Chemical Resistant (CR) Housings

Same features as the standard housings, but molded out of a                                                                    Material ID

chemical resistant PBT/ PC blend.  Suitable for use to -40°C.                                                                  P = Chemical Resistant

Description                             ------------ Part Numbers -------------                        [ 55.8  ]

                                                                                         2.20

Minimum Quantity  ......  500                      50           ...

Red                                     PSBS50RED-BK     PSBS50RED                                                                                        [ 16.5 ]

Gray                                    PSBS50GRA-BK     PSBS50GRA                                                                                         0.65

Blue                      PSBS50BLU-BK     PSBS50BLU

Green                                   PSBS50GRN-BK     PSBS50GRN                                                     [84.8]

Black                     PSBS50BLK-BK     PSBS50BLK                                                     3.34

Brown                                   PSBS50BRN-BK     PSBS50BRN

All Data Subject To Change Without Notice                                                                           www.andersonpower.com                        - 57 -
                         SBS®75X Standard Housings

                         Polycarbonate housings feature 4 auxiliary and 2 primary positions                                                                         Front View

                         all finger proof. Genderless design mates with itself, or the PCB                                                                 Primary Power Contacts

                         connector.  Mechanical keys are color coded.

                         Description                            ------------ Part Numbers -------------                                                                                                [ 15.2 ]

                         Minimum Quantity  .....            250           50              ...                                                                                                  0.60

                         Black                    SBS75XBLK-BK           SBS75XBLK                                                                         Pin                  Socket

                         Brown                                  SBS75XBRN-BK           SBS75XBRN                                                                               [ 46.0 ] 1.81

                         SBS®75X Chemical Resistant (CR) Housings                                                        Bottom       View

                         Same features as the standard housings, but molded out of a                                                                                                                               [  28.9  ]

                         chemical resistant PBT/ PC blend.  Suitable for use to -40°C.                                                                                                                                1.14

                                                                                                                                                     [  32.5 ]

                         Description                            ------------ Part Numbers --------------                [  55.9     ]                                 1.28

                                                                                                             2.20                                                                                  [ 84.8 ]

                         Minimum Quantity  .....             250          50               ....                                                                                                    3.34

                         Green                                  PSBS75XGRN-BK           -                                                                             [ 32.5   ±   0.13 ]              Mated Length

                         Black                    PSBS75XBLK-BK          PSBS75XBLK                                                                     0.750    ±   0.005

                                                                                                                      Material ID

                                                                                                                      P = Chemical    Resistant

                         SBS®75X Assembled PCB Connector

                         Fully assembled PCB connector is designed to mate with SBS®75X                                                                                                  Mated Length

                         Wire connector. All positions are preloaded with contacts including                                                                       Side View

                         standard mating length auxiliary positions. Press fit board locks                                                                                                         [ 74.9 ]

                         help secure the connector to the PCB before and after soldering.                                Back View    [ 15.7 ]                      [ 46.1 ]                         2.95

                                                                                                                                      0.62                           1.81

                         Description                            ---- Part Number -----

                         Minimum Quantity  .....  100             .....