器件描述

Relay Sockets u0026 Hardware SOCKETMM3 RELAY

参数

产品属性属性值
产品种类:
Product Category:
Relay Sockets & Hardware
制造商:
Manufacturer:
Omron
RoHS:YES
Accessory Type:Socket
Associated Relay Series:MMK
应用:
Application:
Front connecting socket, track or screw mount
商标:
Brand:
Omron Automation and Safety
安装风格:
Mounting Style:
DIN Rail
Number of Contacts:11
Factory Pack Quantityxcewtfdcdaryef:20

11PFA器件文档内容

Latching Relay

MMK

                                                                                                                                   CSM_MMK_DS_E_5_2

Mechanically Latching Relays Based on the

MM Power Relay

• Low power consumption due to mechanical latch for economic op-

eration.

• Relays with mixed coil specifications can be produced (e.g., AC set

coil and DC reset coil).

• Operational response fast enough to enable pulse signal power ap-

plications.

• Ambient operating temperature: –10°C to 55°C.

       Refer to Safety Precautions for All Relays.

Ordering Information

              Type                                  Contact  form                               Open  structure                       Cased

                                                                                 Solder  terminals          Screw  terminals  Plug-in (octal pins)

                                                                                                                                      terminals

Standard                           DPDT                                     MM2K                       MM2KB                  MM2KP

                                   3PDT                                     MM3K                       MM3KB                  MM3KP

                                   4PDT                                     MM4K                       MM4KB                  ---

                                   DPDT+DPST-NO                             ---                        ---                    MM4KP

DC-switching                       DPDT                                     MM2XK                      MM2XKB                 MM2XKP

                                   3PDT                                     MM3XK                      MM3XKB                 MM3XKP

                                   4PDT                                     MM4XK                      MM4XKB                 ---

                                   DPDT+DPST-NO                             ---                        ---                    MM4XKP

Conforming to auxiliary     power  DPDT+DPST-NO                             ---                        ---                    MM4KP-JD

relay specifications                                                                                                          MM4XKP-JD

Models Conforming to Auxiliary Power Relay Specifications

The MM4KP-JD and MM4XKP-JD satisfy the ratings of auxiliary relays provided in JEC-2500 (1987) standards for power protective relays specified

by the Japan Electromechanical Commission. Furthermore, the MM4KP-JD and MM4XKP-JD satisfy the ratings of multi-contact relays provided

in JEC-174D (1979) standards for power auxiliary relays.

These models work at operation level A specified by JEC-174D (1979) standards and the hot start of the relays is possible after the coils radiate

heat.

In accordance with JEC-2500 (1987) standards, the coil of each model withstands a 130% DC load or 115% AC load.

Note:  When ordering, add the rated coil voltage to the model number. Rated coil voltages are given in the coil ratings table.

                      Example: MM2K, 6 VAC

                                                    Rated coil voltage

■ Available Models

Open Coils          (with   Solder                  Terminals)

                      Type                                   Contact  form               Relay  model              Available rated voltage

Standard                                            DPDT                         MM2K                       100/(110), 200/(220) VAC

                                                                                                            12, 24, 48, 100/110, 200/220 VDC

                                                    3PDT                         MM3K                       100/(110), 200/(220) VAC

                                                                                                            48, 100/110 VDC

                                                    4PDT                         MM4K                       200/(220) VAC

                                                                                                            12, 24, 48, 100/110, 200/220 VDC

DC-switching                                        DPDT                         MM2XK                      24, 100/110 VDC

                                                    3PDT                         MM3XK                      200/(220) VAC

                                                                                                            100/110 VDC

                                                    4PDT                         MM4XK                      100/(110) VAC

                                                                                                            100/110 VDC

                                                                                                                                                     1
                                                                                                                          MMK

Open Coils (with Screw Terminals)

                      Type                       Contact  form      Relay  model              Available rated voltage

Standard                                     DPDT               MM2KB                100/(110), 200/(220) VAC

                                                                                     12, 24, 48, 100/110 VDC

                                             3PDT               MM3KB                100/(110), 200/(220) VAC

                                                                                     12, 48, 100/110 VDC

                                             4PDT               MM4KB                24, 100/(110), 200/(220) VAC

                                                                                     100/110 VDC

DC-switching                                 DPDT               MM2XKB               100/(110), 200/(220) VAC

                                                                                     12, 24, 48, 100/110, 200/220 VDC

                                             3PDT               MM3XKB               200/(220) VAC

                                                                                     24, 100/110 VDC

                                             4PDT               MM4XKB               24, 48, 100/110, 125, 200/220 VDC

Cased Coils (Plug-in Terminals)

                      Type                       Contact  form      Relay model               Available rated voltage

Standard                                     DP                 MM2KP                6, 12, 24, 100/(110), 200/(220) VAC

                                                                                     12, 24, 48, 100/110, 125, 200/220 VDC

                                             3P                 MM3KP                24, 100/(110), 200/(220) VAC

                                                                                     6, 12, 24, 48, 100/110, 125, 200/220 VDC

                                             4P                 MM4KP                24, 100/(110), 200/(220) VAC

                                                                                     6, 12, 24, 48, 100/110, 125, 200/220 VDC

DC-switching                                 DP                 MM2XKP               24, 100/(110), 200/(220) VAC

                                                                                     12, 24, 48, 100/110, 125, 200/220 VDC

                                             3P                 MM3XKP               100/(110), 200/(220) VAC

                                                                                     24, 48, 100/110, 125, 200/220 VDC

                                             4P                 MM4XKP               100/(110), 200/(220) VAC

                                                                                     6, 12, 24, 48, 100/110, 125, 200/220 VDC

Conforming to auxiliary power relay          4P                 MM4KP-JD             24, 100/(110), 115, 200/(220) VAC

specifications                                                                       24, 100/110, 125, 200/220 VDC

Conforming to auxiliary power relay          4P                 MM4XKP-JD            100/(110), 115, 200/(220) VAC

specifications for DC-switching                                                      24, 48, 100/110, 125, 200/220 VDC

Model Number Legend

MM@@K@

    1     2     3

1.  Contact Form                                                3.  Terminal Shape

    2:          DPDT                                                   None: Solder

    3:          3PDT                                                   B:  Screw

    4:          4PDT (open structure type)/                            P:  Plug-in

                DPDT+DPST-NO (cased type)                       Note: The suffix “JD” indicates models conforming to auxiliary power

2.  Type (see note)                                                    relay specifications.

    None:       Standard

    X:          DC-switching

                                                                                                                                      2
                                                                                                                                             MMK

■ Accessories                   (Order Separately)

Sockets

             Relay                                  DIN Track/Front-connecting       Socket               Back-connecting Socket

                                                               Screw terminals                                   Solder terminals

MM2(X)KP                                     11PFA                                                  PL11

MM3(X)KP                                     14PFA                                                  PL15

MM4(X)KP

MM4(X)KP-JD                                  14PFA                                                  ---

Mounting Brackets

           Contact form                             Model

DPDT                                 R99-03  (S KANAGU) FOR         MM2K.611K

3PDT                                 R99-03  (S KANAGU) FOR         MM3K.612K

4PDT                                 R99-03  (S KANAGU) FOR         MM4K.613K

Specifications

■ Coil Ratings

Set Coil

    Rated                               Rated current (mA)                             Coil resistance    Set    Max    Power consumption

voltage (V)                      DP                                 3P,  4P                    (Ω)        volt.  volt.            (VA or W)

             Open        Relays         Cased       Open Relays               Cased

             50 Hz       60 Hz   50 Hz       60 Hz  50 Hz      60 Hz     50 Hz  60 Hz  DP      3P, 4P     % of rated

                                                                                                          voltage

AC    6      790         655     690    590         1,285      1,100     1,165  1,000  1.1     0.46       80%    110%   Initial:

      12     395         325     345    295         640        550       580    500    4.7     1.9        max.          DP: Approx. 6.2

      24     195         160     170    145         320        275       290    250    19      8.2                      3P, 4P: Approx. 12

      50     94          78      82     70          154        132       140    120    82      34                       Rated:

      100/   47          39/45   41     35/40       77         66/76     70     60/68  340     141                      DP: Approx. 3.5 (3.9)

      (110)                                                                                                             3P, 4P: Approx. 6 (6.6)∗

      200/   23.5        19.5/   20.5   17.5/       38.5       33/38     35     30/34  1,540   563

      (220)              22.5           20

DC    6      340                                    450                                17.5    13.4                     DP: Approx. 2.1

      12     176                                    220                                68      54                       3P, 4P: Approx. 2.7

      24     87                                     94                                 275     255

      48     41                                     52                                 1,180   930

      100/   17/19                                  22/24.5                            5,750   4,500

      110

      200/   8.6/9.5                                11/12                              23,200  18,000

      220

Note: 1.  The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and

          ±15% for DC coil resistance.

      2.  Performance characteristic data are measured at a coil temperature of 23°C.

      3.  The AC coil resistance values are reference values.

      4.  The maximum voltage is one that is applicable instantaneously to the Relay coil at an ambient temperature of 23°C and not continuously.

      ∗Values in parentheses are for open relays.

                                                                                                                                                   3
                                                                                                                                              MMK

Reset Coil

Rated voltage    (V)         Rated current (mA)          Coil resistance         Reset voltage            Maximum voltage        Power consumption

                             50 Hz           60 Hz                (Ω)                         % of rated voltage                    (VA or W)

AC  6                 770               690             2.3                  80% max.                  110%                      Initial: Approx. 6.5

    12                385               345             9.2                                                                      Rated: Approx. 4.1

    24                191               170             35

    50                92                82              175

    100/(110)         46                41/46           739

    200/(220)         23                20/23           3,030

DC  6                 422                               14.2                                                                     Approx. 2.8

    12                215                               56

    24                109                               220

    48                58                                832

    100/110           25/27                             4,040

    200/220           12.2/13.5                         16,330

Note: 1.  The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and

          ±15% for DC coil resistance.

    2.    Performance characteristic data are measured at a coil temperature of 23°C.

    3.    The AC coil resistance values are reference values.

    4.    The maximum voltage is one that is applicable instantaneously to the Relay coil at an ambient temperature of 23°C and not continuously.

Coils (Conforming to Auxiliary Power Relay Specifications)

    Rated             Rated current (mA)            Coil resistance       Set        Reset    Max.     Opera-     Power consumption (VA or W)

voltage (V)                                                  (Ω)        voltage      voltage  voltage     tion

                   Set coil         Reset coil      Set         Reset                                  level           Set coil          Reset coil

                                                    coil          coil                                 (JEC-

             50 Hz    60 Hz         50 Hz    60 Hz                        % of rated voltage           174D)      Initial  Rated    Initial   Rated

AC  24       245      210    191            170     8.5        35       80%          80%      110%     A          Approx.  Approx.  Approx.   Approx.

    50       117      102    92             82      36         175      max.         max.                         6.3      5.1      6.5       4.1

    100/     58.5     51/58  46             41/46   150        739

    (110)

    110      53       46     42             37.3    182        835

    115      51       44     40             35.7    210        885

    200/     29       25.5/  23             20.5/   620        3,030

    (220)             29                    23

    220      26.5     23     21             18.6    780        3,420

DC  24       94              109                    255        220                                                Approx. 2.7       Approx. 2.8

    48       52              58                     930        832

    100/     22/24.5         25/27                  4,500      4,040

    110

    125      22              23.5                   5,800      5,330

    200/     11/12           12.2/13.5              18,000     16,330

    220

Note: 1.  The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and

          ±15% for DC coil resistance.

    2.    The AC coil resistance and coil inductance values are for reference only.

    3.    Performance characteristic data are measured at a coil temperature of 23°C.

    4.    The maximum voltage is one that is applicable instantaneously to the Relay coil at an ambient temperature of 23°C and not continuously.

                                                                                                                                                       4
                                                                                                                                       MMK

■ Contact Ratings

Standard Relays

            Item              Open Relays: MM2K(B), MM3K(B), MM4K(B)                              Cased Relays: MM2KP, MM3KP, MM4KP

                                Resistive load            Inductive load                          Resistive load             Inductive load

                                (cosφ = 1)             (cosφ=0.4, L/R=7 ms)                       (cosφ = 1)      (cosφ=0.4, L/R=7 ms)

Contact mechanism       Single

Contact material        Ag

Rated load              10 A at 220 VAC                                         5 A at 220 VAC

                        7 A at 24 VDC                                           4 A at 24 VDC

Rated carry current     10 A                                                    5A

Max. switching voltage  250 VAC, 250 VDC                                        250 VAC, 250 VDC

Max. switching current  10 A                                                    5A

Max. switching power    2,200 VA, 168 W                                         1,100 VA, 96W

(reference value)

DC-switching Relays

            Item        Open Relays: MM2XK(B), MM3XK(B), MM4XK(B)                                 Cased Relays: MM2XKP, MM3XKP, MM4XKP

                                Resistive load            Inductive load                          Resistive load             Inductive load

                                (cosφ = 1)             (cosφ=0.4, L/R=7 ms)                       (cosφ = 1)      (cosφ=0.4, L/R=7 ms)

Contact mechanism       Single

Contact material        Ag

Rated load              7 A at 110 VDC          6 A at 110 VDC                  5 A at 110 VDC

Rated current flow      10 A                                                    5A

Max. switching voltage  250 VAC, 250 VDC                                        250 VAC, 250 VDC

Max. switching current  10 A                                                    5A

Max. switching power    800 W, 20 VA *1         660 W, 20 VA *1                 700 W, 20 VA *1                   600 W, 20 VA *1

(reference value)

Note: 1.  When switching DC inductive loads at 125 V or more, an unstable region exists for a switching current of between 0.5 and

          2.5 A. The Relay will not turn OFF in this region. Use a switching current of 0.5 A or less when switching 125 VDC or more.

2.        If L/R exceeds 7 ms when switching DC inductive loads, an arc-breaking time of up to 50 ms must be considered in application and the

          circuit must be designed to ensure that an arc-breaking time of 50 ms is not exceeded.

*1.Refer to Switching an Switching an AC Load with a DC-switching Model (“X” Model) on page 13.

Contacts (Conforming to Auxiliary Power Relay Specifications)

            Item                                MM4KP-JD                                                          MM4XKP-JD

                                Resistive load            Inductive load                          Resistive load             Inductive load

                                (cosφ = 1)             (cosφ = 0.4, L/R= 7 ms)                    (cosφ = 1)      (cosφ = 0.4, L/R= 7 ms)

Contact mechanism       Single

Contact material        Ag

Rated load              5 A at 220 VAC, 4 A at 24 VDC                           5 A at 110 VDC

Rated carry current     5A

Max. switching voltage  250 VAC, 250 VDC

Max. switching current  5A

Note: 1.  When switching DC inductive loads at 125 V or more, an unstable region exists for a switching current of between 0.5 and

          2.5 A. The Relay will not turn OFF in this region. Use a switching current of 0.5 A or less when switching 125 VDC or more.

2.        If L/R exceeds 7 ms when switching DC inductive loads, an arc-breaking time of up to 50 ms must be considered in application and the

          circuit must be designed to ensure that an arc-breaking time of 50 ms is not exceeded.

                                                                                                                                                5
                                                                                                                                 MMK

■ Characteristics

                     Item                                          Open or bifurcated-contact Relays

Contact resistance (see note 2)     50 mΩ max.

Set time (see note 3)               AC: 30 ms max.; DC: 60 ms max. (minimum pulse width for AC and DC: 100 ms)

Reset time (see note 3)             30 ms max. (minimum pulse width for AC and DC: 100 ms)

Max. operating frequency            Mechanical:     1,800 operations/hr

                                    Electrical:     1,800 operations/hr (under rated load)

Insulation resistance (see note 4)  100 MΩ min. (at 500 VDC)

Dielectric strength                 1,500 VAC, 50/60 Hz for 1 min between contacts of same polarity

                                    2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity, between contacts and   coil,          and

                                    between set and reset coils

Vibration resistance                Destruction:    10 to 55 to 10 Hz, 0.375 mm single amplitude (0.75 mm double amplitude)

                                    Malfunction:    10 to 35 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)

Shock resistance                    Destruction:    500 m/s2

                                    Malfunction:    50 m/s2

Endurance                           Mechanical:     2,500,000 operations min. (at 1,800 operations/hr)

                                    Electrical:     500,000 operations min. (at 1,800 operations/hr under rated load) (see note  5)

Error rate (level P)                10 mA at 5 VDC

(Reference value)

(see note 6)

Ambient temperature                 Operating: –10°C to 55°C (with no icing or condensation)

Ambient humidity                    Operating: 5% to 85%

Weight                              Standard Relays                DC-switching Relays

                                    MM2K:           Approx. 255 g  MM2XK:                Approx. 260 g

                                    MM3K:           Approx. 390 g  MM2XK:                Approx. 395 g

                                    MM4K:           Approx. 420 g  MM4XK:                Approx. 430 g

                                    MM2KP:          Approx. 375 g  MM2XKP:               Approx. 380 g

                                    MM3KP:          Approx. 550 g  MM3XKP:               Approx. 555 g

                                    MM4KP:          Approx. 570 g  MM4XKP:               Approx. 580 g

Note: 1.  The data shown above are initial values.

2.        The contact resistance was measured with 1 A at 5 VDC using the voltage drop method.

3.        The set or reset time was measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature of 23°C.

4.        The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for checking the dielectric

          strength.

5.        The electrical endurance was measured at an ambient temperature of 23°C.

6.        This value was measured at a switching frequency of 60 operations per minute.

■ Characteristics (Conforming to Auxiliary Power Relay Specifications)

Vibration resistance                Destruction:    10 to 55 to 10 Hz, 0.375 mm single amplitude (0.75 mm double amplitude)

                                    Malfunction:    10 to 22 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)

Shock resistance                    Destruction:    300 m/s2

                                    Malfunction:    30 m/s2

Endurance                           Mechanical:     2,500,000 operations min. (at 1,800 operations/hr)

                                    Electrical:     500,000 operations min. (at 1,800 operations/hr under rated load) (see note  2)

Error rate (level P)                10 mA at 5 VDC

(Reference value)

(see note 3)

Ambient temperature                 Operating:      –10°C to 40°C (with no icing or condensation)

Ambient humidity                    Operating:      5% to 85%

Weight                              MM4KP-JD:       Approx. 570 g

                                    MM4XKP-JD:      Approx. 580 g

Note: 1.  The data shown above are initial values.

2.        The electrical endurance was measured at an ambient temperature of 23°C.

3.        This value was measured at a switching frequency of 60 operations per minute.

                                                                                                                                                     6
                                                                                                                                                                        MMK

Engineering Data

■ Standard Relays

Maximum Switching Power

Open Relays                                                                            Cased                       Relays

                              MM@K(B)                                                                                            MM@KP

Switching current (A)                            AC resistive load

                                                                                       Switching current (A)                              AC resistive load

                                            AC inductive load

                                            (cosφ = 0.4)

                                                                                                                                       AC inductive load

                                                                                                                                       (cosφ = 0.4)

                                            DC resistive load

                                                                                                                                       DC resistive load

                              DC inductive load                                                                    DC inductive  load

                              (L/R = 7 ms)                                                                         (L/R = 7 ms)

                              Switching voltage (V)                                                                Switching current (A)

Endurance Curves

Open Relays                                                                            Cased                       Relays

                              MM@K(B)                                                                                            MM@KP

operations)  10,000                                                       operations)  10,000

                       5,000                                                           5,000

                       3,000                     220 VAC resistive  load               3,000

(x103                                            Inductive load           (x103

                                                 (cosφ = 0.4)                                                                          220 VAC resistive     load

                                                                                                                                       Inductive load

Endurance              1,000                                              Endurance    1,000                                           (cosφ = 0.4)

                       500                                                                                    500

                       300                  24 VDC resistive load                                             300  24 VDC resistive load

                                            Inductive load                                                         Inductive load

                                            L/R = 7 ms                                                             L/R = 7 ms

                              Switching current (A)                                                                Switching current (A)

■ DC-switching Relays

Maximum Switching Power

Open Relays                                                                            Cased                       Relays

                              MM@XK(B)                                                                                           MM@XKP

Switching current (A)                            DC resistive load                     Switching current (A)                                         DC resistive load

                              DC inductive load                                                                    DC inductive load

                              L/R=7 ms                                                                             L/R=7 ms

                              Switching voltage (V)                                                                        Switching voltage (V)

                                                                                                                                                                             7
                                                                                                                                                                                                   MMK

Endurance Curves

Open Relays                                                                                                    Cased                                        Relays

                                                                   MM@XK(B)                                                                                             MM@XKP

operations)                                10,000                                                              operations)  10,000

                                           5,000                                                                                     5,000

                                           3,000                                                                                     3,000

3                                                                                                              3

(x10                                                                           110 VDC        resistive  load  (x10                                                                110 VDC

                                                                                                                                                                                   resistive load

Endurance                                  1,000                                                               Endurance             1,000                                         Inductive load

                                                                                                                                                                                   L/R=7 ms

                                           500                                                                                       500

                                           300                     110 VDC inductive load                                            300

                                                                   (L/R 7 ms)

                                                               Switching current (A)                                                                        Switching current (A)

■                   Relays Conforming to                                                          Auxiliary                 Power Relay Specifications

                    Maximum Switching Power

                    MM4KP-JD                                                                                                                                MMX4KP-JD

                                                   AC inductive load           AC resistive load                                                                        DC resistive load

                    Switching current (A)          cosφ = 0.4                                                                        Switching current (A)

                                                                                                                                                            DC inductive load

                                                                                                                                                            L/R = 7 ms

                                                                           DC resistive load

                                                   DC inductive load

                                                   L/R = 7 ms

                                                                           Switching voltage (V)                                                                        Switching voltage (V)

                    Endurance Curves

                    MM4KP-JD                                                                                                                                MM4XKP-JD

Endurance (x 104 )                                                                                                Endurance (x 104)                                    110 VDC resistive load

                                                               220 VAC resistive load                                                                                  Inductive load

                                                               Inductive load                                                                                          L/R = 7 ms

                                                               cosφ = 0.4

                                                   24 VDC resistive load

                                                   Inductive load

                                                   L/R = 7 ms

                                                                      Switching current (A)                                                                             Switching current (A)

                                                                                                                                                                                                        8
                                                                                                                                                                                                 MMK

Ambient Temperature vs.                                                 Ambient Temperature vs.                                                  Malfunctioning Shock

Set and Reset Voltage                                                   Coil Temperature Rise                                                    MM4(X)KP

MM4KP AC (60 Hz)                                                        MM4KP 110 VAC (60 Hz)                                                                               60 min.  Reset

Must-operate and reset voltage (%)  Number of Relays: 5  Set voltage    Coil temperature rise (° C)  Number of Relays: 5

                                                         Reset voltage                                                                           60 min.                                    60 min.

                                                                                                                                                 60 min.                             60 min.

                                                                                                                          Contact carry current

                                                                                                                          Set coil

                                                                                                                          Reset coil                                   60 min.       Unit: m/s2

                                                                                                                                                 Number of samples: 3

                                              Ambient temperature (°C)                               Ambient temperature (°C)                    Measurement conditions: Impose a shock of

                                                                                                                                                 50 m/s2 in the ±X, ±Y, and ±Z directions three

                                    MM4KP DC                            MM4KP DC                                                                 times each with the Relay energized and not

                                                                                                                                                 energized to check the shock values that cause

Must-operate and reset voltage (%)                       Set voltage    Coil temperature rise (° C)  Number of Relays: 5                         the Relay to malfunction.

                                    Number of Relays: 5

                                                         Reset voltage

                                                                                                                                                           Shock direction

                                                                                                     Contact carry current

                                                                                                                          Set coil

                                                                                                                          Reset coil

                                              Ambient temperature (°C)                               Ambient temperature (°C)

                                                                                                                                                                                                      9
                                                                                                                                                                                    MMK

Dimensions

Note: All units are in millimeters unless otherwise indicated.

■ Open Relays with Solder Terminals

MM2(X)K,

MM3(X)K,                                   MM2(X)K                            MM3(X)K                            MM4(X)K                                  Side View

MM4(X)K

                                               2P    1P                       3P      2P     1P                  4P  3P    2P     1P                            Common C

                                                                                                                                                                      Stationary     A

                                                                                                                                                                      Stationary     B

                              86 max.                                                                94 max.                                                          Set coil

                                                                 94 max.

                                                                                                                                                                      Reset coil

                                               22                                                                                                         29          15 max.

                                               ±0.2                                                                  34                                   ±0.2

                                                                                      28                             ±0.2

                                               44 max.                                ±0.2                           63 max.              Two, M4         58.5 max.

MM2K                                                                                50 max.                                               mounting holes

                                           Note:           Connect the common (C) of MM@XK to                    positive (+).

■ Open      Relays                with Screw Terminals

MM2(X)KB,

MM3(X)KB,                     MM2(X)KB                                  MM3(X)KB                                     MM4(X)KB                             Side  View

MM4(X)KB

                                  2P       1P                             3P      2P  1P                             4P  3P    2P     1P                            Common C

                                                   Ten, M3.5 x                               Thirteen,                                    Sixteen,

                                                   5.5 terminal                              M3.5 x 5.5                                   M3.5 x 5.5

                                                   screws                                    terminal                                     terminal                            Station-

                                                                                             screws                                       screws                              ary A

                                                                                                                                                                              Station-

                    92 max.                                                                                                                                                   ary B

                                                           101 max.                                    101 max.                                                               Set

                                                                                                                                                                              coil

                                                                                                                                                                              Reset

                                                                                                                                                                              coil

                                  22                                          28                                           34                                   29    15 max.

                                  ±0.2                                        ±0.2                                         ±0.2                                 ±0.2

                                  60 max.                                  60 max.                                       68 max.          Two, M4

                                                                                                                                          mounting holes  58.5 max.

MM2KB                                                      Connect the common (C) of MM@XKB to positive (+).

                                               Note:

Mounting Holes (Direct Mounting)

Note:     The tolerance is ±0.2.

Two, 4.5-dia. mounting holes

                              Dimensions of : l

            29±0.2            2-pole: 22±0.2 mm

                              3-pole: 28±0.2 mm

                              4-pole: 34±0.2 mm

       l

Mounting Bracket (S Bracket)                                                                              Item           R99-03                       R99-03                  R99-03

R99-03 (S KANAGU) FOR MM@                                                                                            (S KANAGU)                    (S KANAGU)         (S KANAGU)

                                                                                                                 FOR MM2K.611K            FOR MM3K.612K               FOR MM4K.613K

                                                                                                                         (DPDT)                       (3PDT)                  (4PDT)

The S Bracket can be                                    W               H                              l         22±0.2                   28±0.2                      34±0.2

used to mount a Relay                                                                                  D         71 max.                  71 max.                     71 max.

with open solder or screw

terminals.                                                                                             W         33 max.                  39 max.                     45 max.

                                  D   29±0.2                    60±0.2        50                       H         6 max.                   6 max.                      6 max.

                                                        l

                                                                                                                                                                                         10
                                                                                                                                                             MMK

■ Cased        Relays with Plug-in Terminal

MM2(X)KP                                                                            Terminal Arrangement/

                                                                                    Internal Connections

                            54.5 max. (see note)                                    (Bottom View)

                                    22                    119 max.
                                    3.5
                                                                                 7

                      5                                                             Standard Relays          DC-switching Relays

                                                                                    MM2KP                    MM2XKP

                 80.5 max.                                                                      RESET                               RESET

                      64.5

                      max.

MM2KP            Note:      It is recommended that 55 mm min. is allowed                        SET                                 SET

                            for this side because the MM2XKP has a

                            curved protective plate on the side.                         Note:  Connect the common (C) to positive (+).

                                                                                                Make sure that all common connections are the

                                                                                                same in polarity. The markings of the common

                                                                                                connections on the casing all show "+" but the

                                                                                                polarity of the common connections can be ei-

                                                                                                ther all negative or all positive.

MM3(X)KP                                      72.5 max.

MM4(X)KP                                      (see note)

                                                                    123 max.

                 80.5 max.                                                                      Note:        It is recommended that 73 mm min.

                            64.5                                                                             is allowed for this side because the

                            max.

                                                                                                             MM3XKP and MM4XKP have a

                                                                                                             curved protective plate on the side.

MM4KP

Terminal Arrangement/

Internal Connections

(Bottom View)

Standard Relays                                                                  DC-switching Relays

MM3KP                               MM4KP                                        MM3XKP                      MM4XKP

Note:  Connect the common (C) to positive (+).

       Make sure that all common connections are the same in polarity. The markings of the common connections on the casing all

       show "+" but the polarity of the common connections can be either all negative or all positive.

Cases on Models for Switching DC Loads

As shown at the right, there are three holes                                        Be sure the polarity is

with a 10-mm diameter in the case.                        Case Protective Plate     correct when connecting

                                                                                    Exposed Models.

                                                                                                             This example is for the MN2XK.

                                                                                                             This also applies to models with 3 or 4 poles.

                                                                                                                                                                  11
                                                                                                                                     MMK

MM4KP-JD                                                                                        Terminal Arrangement/

                                                                                                Internal Connections

                                                                                                (Bottom View)

                                      72.5 max.

                                                          123 max.

                     70.5 max.

                       64.5

                       max.

                                                                                        Note:   The MM4KP-JD is DPDT and

                                                                                                DPST-NO.

MM4XKP-JD

                                      73 max.

                                                          123 max.

                     70.5 max.

                                64.5

                                max.

                                                                                Note:   The MM4XKP-JD is DPDT and DPST-

                                                                                        NO. Make sure that all common connec-

                                                                                        tions are the same in polarity. The mark-

                                                                                        ings of the common connections on the

                                                                                        casing all show "+" but the polarity of the

                                                                                        common connections can be either all

                                                                                        negative or all positive.

Accessories

■ Sockets

          Relay model                              DIN  Track/Front-connecting  Socket                Back-connecting Socket

                                                          Screw terminals                                 Solder terminals

MM2(X)KP                              11PFA                                                PL11

MM3(X)KP                              14PFA                                                PL15

MM4(X)KP

MM4(X)KP-JD                           14PFA                                                ---

Note: When using the MM@KP-JD by itself, the PL15 Back-connecting  Socket cannot be used.

■ Height with Socket

DIN Track/Front-connecting Socket                                  Back-connecting Socket

             MM2KP                    MM3KP

             MM2XKP                   MM3XKP                                                          MM3KP

                                      MM4KP                                     MM2KP                 MM3XKP

                                      MM4XKP                        124         MM2XKP           128  MM4KP

151                  147.5 155        MM4(X)KP-JD  151.5                                              MM4XKP

                                                                                PL11                      PL15

             11PFA                    14PFA

Note:  @PFA can be both track-mounted and screw-mounted.

                                                                                                                                          12
                                                                                                                                            MMK

Safety Precautions

Refer to Safety Precautions for All Relays.

■ Mounting                                                                    •  NC contacts can remain open for a few milliseconds when the reset

                                                                                 coil turns ON and OFF. NO contact can remain open for a few milli-

Make sure that the Relay is free from iron powder or iron core,                  seconds when the set coil turns ON and OFF while the Relay is

otherwise the iron dust may adhere to the Relay. As a result the                 latched. Design your circuits to allow for this.

movable contact may not operate properly.

An arc may be generated between the contacts in switching                                          MMK contact

operation. Be sure to keep combustible objects away from the Relay.                                (NC)

If the arc will have a bad effect around the Relay, the use of a model                             The contact

with a casing is recommended.                                                                      may fail to

                                                                                                   hold itself.

A model switching DC load incorporates an insulation base with a

small built-in permanent magnet. Be sure to keep magnets or ferrous                                Relay coil

objects away from the permanent magnet, otherwise the capacity of

the maximum switching current may drop.

The PL Back-connecting Socket must be flush-mounted from the                  •  Do not allow voltage to be applied simultaneously to both the set

surface of the panel.                                                            and reset coil. If voltage is applied simultaneously, the Relay will be

To minimize the influence of heat, separate Relays from each other               set.

by at least 20 mm for cooling when mounting multiple Relays                   •  There is no reason to apply voltage to Latching Relays continu-

together.                                                                        ously because they will latch properly with a single pulse of suffi-

                                                                                 cient width. Continuously applying voltage will only waste power.

           Top          20 mm                                                 •  A model for DC loads incorporates a permanent magnetic for arc

                        min.                                                     suppression. Keep floppy disks away from the Relay, otherwise the

                   MMK             MMK                                           data on the floppy disk may be damaged.

                                          Normal mounting direction           •  Arcing when switching DC power can cause nitric gas to be

           Bottom                                                                generated. The case of the MM@XKP contains holes to allow the

Be sure to mount the Relay so that the movable contact is in the                 gas to escape. This, however, makes it possible for dust and dirt to

downward direction.                                                              enter the case. Be sure to use the MM@XKP in a suitable

                                                                                 environment.

■ Connection

• When connecting a load to the contact terminals of a model for

switching DC loads (“X” models), consider the polarity of the con-

tact terminals so that the generated arcs on the adjacent poles will

not collide. (For example, if the common connections of the Relay

are all positive or all negative, no arc collision will occur.)

• Use proper crimp terminals or 1.2- to 2-mm-dia. single-conductor

wire to connect screw terminals.

Screw Terminal Model                                                          ■ Switching an AC Load with a

Do not bend the coil terminals, otherwise the coil wire may be dis-              DC-switching Model (“X” Model)

connected. Make sure that the tightening torque applied to each ter-

minal is 1.27 N • m and the insertion force is 49 N for 10 s.                 DC-switching Relays (“X” models) use a magnet to extinguish arcs.

Solder Terminal Model                                                         The polarity must be correct when you connect the switching section.

                                                                              However, if you connect an AC load, the positive and negative poles

Make sure that Relay terminals are free of flux or other foreign sub-         of the power supply alternate. This can cause short-circuits due to

stance  before     soldering  the  Relay  terminals.  Finish  soldering  the  the collision of arcs that occur when the Relay turns OFF.

Relay terminals quickly, otherwise the coil wire may be broken.               Therefore, the switching capacity for an AC load is specified as 20 VA

                                                                              or less to prevent short circuits caused by arc collisions.

                                                                              Take sufficient caution if you switch an AC Load with a DC-switching

■ Circuits                                                                    model (“X” models).

• You cannot use single contact to demagnetize the set coil as shown          ■ Refer to the technical guide on

below.

                                                                                 your OMRON website for

                                                                                 technical descriptions and

                                        Load                                     FAQs on the product.

                        Latching Relay coil

                        NC contact of the Relay

                       ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                       To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                   In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                                          13
                                                     Terms and Conditions Agreement

Read and understand this catalog.

Please read and understand this catalog before purchasing the products.                 Please consult your OMRON representative if you

have any questions or comments.

Warranties.

(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship

for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron

disclaims all other warranties, express or implied.

(b)  Limitations.      OMRON    MAKES           NO   WARRANTY          OR   REPRESENTATION,         EXPRESS             OR   IMPLIED,      ABOUT

NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER

ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE

PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.

Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the

Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at

Omron’s     election,  to  (i)  replace    (in  the  form  originally  shipped    with  Buyer  responsible  for  labor  charges  for  removal            or

replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount

equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,

repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products

were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate

modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall

not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or

electronic   components,        circuits,  system    assemblies  or    any  other  materials   or   substances   or  environments.    Any  advice,

recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above

warranty.

See http://www.omron.com/global/           or contact your Omron representative for published information.

Limitation on Liability; Etc.

OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,

LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,

WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.

Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.

Omron     Companies    shall    not  be    responsible     for  conformity  with  any   standards,  codes   or  regulations  which  apply  to            the

combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable

third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself

is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,

system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product

with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE

QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE

OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.

Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence

thereof.

Performance Data.

Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining

suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate

it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.

Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our

practice to change part numbers when published ratings or features are changed, or when significant construction changes are

made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers

may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at

any time to confirm actual specifications of purchased Product.

Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.

                                                                                                                                           2014.10

                                                           In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

http://www.ia.omron.com/                                                                       (c)Copyright OMRON Corporation 2014 All Right Reserved.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

11PFA   14PFA  MM2KP-AC120  MM2KP-AC24  MM4KP DC24  MM4KP-AC120       MM4KP-AC200/220  MM4XKP-

DC125  MM2KP AC200      MM2KP AC220  MM2XKP DC125  MM3XKP DC125  MM4KP AC110  MM4KP DC100/110

MM4KP DC125    MM4XKP AC100/(110)    MM4XKP AC125  MM2KB AC100/(110)  MM2KP DC100/110  MM3KP DC12